Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Simulation Timestamp: 2023-10-16 09:14:28
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1637.92 | 522.53 | 580.00 |
| Net Site Energy | 1637.92 | 522.53 | 580.00 |
| Total Source Energy | 4463.82 | 1424.04 | 1580.69 |
| Net Source Energy | 4463.82 | 1424.04 | 1580.69 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 347.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 108.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 102.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 472.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1290.60 | 347.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 347.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 108.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 50.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 102.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 472.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 347.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 108.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 50.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 102.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 472.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 241.76 | 122.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 457.01 | 122.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 217.80 | 110.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 411.73 | 110.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1290.599 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1290.599 | 100.00 |
| Total On-Site and Utility Electric Sources | 1290.599 | 100.00 |
| Total Electricity End Uses | 1290.599 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 49.91 |
| Air to Air Heat Recovery for Heating | 0.00 | 50.09 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8755.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
| Latitude [deg] | 39.72 |
| Longitude [deg] | -104.8 |
| Elevation [m] | 1726.00 |
| Time Zone | -7.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 16-AUG-16:40 | 22-DEC-03:00 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 111916.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 25666.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 4289.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22709.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 9184.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 30146.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 91996.99 | 111916.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 111916.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 25666.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4034.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 254.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 9184.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 30146.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 376.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 342.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 323.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1495.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 4087.33 | 376.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 133.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 121.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 56.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 114.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 529.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1447.37 | 133.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 120.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 109.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 103.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 477.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1303.93 | 120.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.408844 |
| SPLIT GNW SUPPLY FAN | 0.389180 |
| SPLIT OFFICE SUPPLY FAN | 0.447363 |
| SPLIT GNE SUPPLY FAN | 0.344168 |
| SPLIT GN1 SUPPLY FAN | 0.315137 |
| SPLIT GN2 SUPPLY FAN | 0.314200 |
| SPLIT GS1 SUPPLY FAN | 0.336724 |
| SPLIT GS2 SUPPLY FAN | 0.338902 |
| SPLIT MSW SUPPLY FAN | 1.04 |
| SPLIT MNW SUPPLY FAN | 1.01 |
| SPLIT MSE SUPPLY FAN | 0.910583 |
| SPLIT MNE SUPPLY FAN | 0.881565 |
| SPLIT MN1 SUPPLY FAN | 0.791240 |
| SPLIT MN2 SUPPLY FAN | 0.788728 |
| SPLIT MS1 SUPPLY FAN | 0.826822 |
| SPLIT MS2 SUPPLY FAN | 0.824226 |
| SPLIT TSW SUPPLY FAN | 0.577256 |
| SPLIT TNW SUPPLY FAN | 0.572538 |
| SPLIT TSE SUPPLY FAN | 0.483123 |
| SPLIT TNE SUPPLY FAN | 0.478221 |
| SPLIT TN1 SUPPLY FAN | 0.449045 |
| SPLIT TN2 SUPPLY FAN | 0.445913 |
| SPLIT TS1 SUPPLY FAN | 0.455416 |
| SPLIT TS2 SUPPLY FAN | 0.452294 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.408844 |
| G NW APARTMENT DIRECT AIR | 0.389180 |
| OFFICE DIRECT AIR | 0.447363 |
| G NE APARTMENT DIRECT AIR | 0.344168 |
| G N1 APARTMENT DIRECT AIR | 0.315137 |
| G N2 APARTMENT DIRECT AIR | 0.314200 |
| G S1 APARTMENT DIRECT AIR | 0.336724 |
| G S2 APARTMENT DIRECT AIR | 0.338902 |
| M SW APARTMENT DIRECT AIR | 1.04 |
| M NW APARTMENT DIRECT AIR | 1.01 |
| M SE APARTMENT DIRECT AIR | 0.910583 |
| M NE APARTMENT DIRECT AIR | 0.881565 |
| M N1 APARTMENT DIRECT AIR | 0.791240 |
| M N2 APARTMENT DIRECT AIR | 0.788728 |
| M S1 APARTMENT DIRECT AIR | 0.826822 |
| M S2 APARTMENT DIRECT AIR | 0.824226 |
| T SW APARTMENT DIRECT AIR | 0.577256 |
| T NW APARTMENT DIRECT AIR | 0.572538 |
| T SE APARTMENT DIRECT AIR | 0.483123 |
| T NE APARTMENT DIRECT AIR | 0.478221 |
| T N1 APARTMENT DIRECT AIR | 0.449045 |
| T N2 APARTMENT DIRECT AIR | 0.445913 |
| T S1 APARTMENT DIRECT AIR | 0.455416 |
| T S2 APARTMENT DIRECT AIR | 0.452294 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.408844 | 0.408844 | 0.408844 | 0.408844 | 0.408844 | 0.408844 | 1.00 | 1.000000 | 0.408844 |
| SPLIT GNW | 0.389180 | 0.389180 | 0.389180 | 0.389180 | 0.389180 | 0.389180 | 1.00 | 1.000000 | 0.389180 |
| SPLIT OFFICE | 0.447363 | 0.447363 | 0.447363 | 0.447363 | 0.447363 | 0.447363 | 1.00 | 1.00 | 0.447363 |
| SPLIT GNE | 0.344168 | 0.344168 | 0.344168 | 0.344168 | 0.344168 | 0.344168 | 1.00 | 1.00 | 0.344168 |
| SPLIT GN1 | 0.315137 | 0.315137 | 0.315137 | 0.315137 | 0.315137 | 0.315137 | 1.00 | 1.000000 | 0.315137 |
| SPLIT GN2 | 0.314200 | 0.314200 | 0.314200 | 0.314200 | 0.314200 | 0.314200 | 1.00 | 1.00 | 0.314200 |
| SPLIT GS1 | 0.336724 | 0.336724 | 0.336724 | 0.336724 | 0.336724 | 0.336724 | 1.00 | 1.000000 | 0.336724 |
| SPLIT GS2 | 0.338902 | 0.338902 | 0.338902 | 0.338902 | 0.338902 | 0.338902 | 1.00 | 1.00 | 0.338902 |
| SPLIT MSW | 1.04 | 1.04 | 1.04 | 1.04 | 1.04 | 1.04 | 1.00 | 1.00 | 1.04 |
| SPLIT MNW | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.00 | 1.00 | 1.01 |
| SPLIT MSE | 0.910583 | 0.910583 | 0.910583 | 0.910583 | 0.910583 | 0.910583 | 1.00 | 1.000000 | 0.910583 |
| SPLIT MNE | 0.881565 | 0.881565 | 0.881565 | 0.881565 | 0.881565 | 0.881565 | 1.00 | 1.00 | 0.881565 |
| SPLIT MN1 | 0.791240 | 0.791240 | 0.791240 | 0.791240 | 0.791240 | 0.791240 | 1.00 | 1.00 | 0.791240 |
| SPLIT MN2 | 0.788728 | 0.788728 | 0.788728 | 0.788728 | 0.788728 | 0.788728 | 1.00 | 1.00 | 0.788728 |
| SPLIT MS1 | 0.826822 | 0.826822 | 0.826822 | 0.826822 | 0.826822 | 0.826822 | 1.00 | 1.00 | 0.826822 |
| SPLIT MS2 | 0.824226 | 0.824226 | 0.824226 | 0.824226 | 0.824226 | 0.824226 | 1.00 | 1.00 | 0.824226 |
| SPLIT TSW | 0.577256 | 0.577256 | 0.577256 | 0.577256 | 0.577256 | 0.577256 | 1.00 | 1.00 | 0.577256 |
| SPLIT TNW | 0.572538 | 0.572538 | 0.572538 | 0.572538 | 0.572538 | 0.572538 | 1.00 | 1.00 | 0.572538 |
| SPLIT TSE | 0.483123 | 0.483123 | 0.483123 | 0.483123 | 0.483123 | 0.483123 | 1.00 | 1.00 | 0.483123 |
| SPLIT TNE | 0.478221 | 0.478221 | 0.478221 | 0.478221 | 0.478221 | 0.478221 | 1.00 | 1.00 | 0.478221 |
| SPLIT TN1 | 0.449045 | 0.449045 | 0.449045 | 0.449045 | 0.449045 | 0.449045 | 1.00 | 1.00 | 0.449045 |
| SPLIT TN2 | 0.445913 | 0.445913 | 0.445913 | 0.445913 | 0.445913 | 0.445913 | 1.00 | 1.00 | 0.445913 |
| SPLIT TS1 | 0.455416 | 0.455416 | 0.455416 | 0.455416 | 0.455416 | 0.455416 | 1.00 | 1.00 | 0.455416 |
| SPLIT TS2 | 0.452294 | 0.452294 | 0.452294 | 0.452294 | 0.452294 | 0.452294 | 1.00 | 1.00 | 0.452294 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.408844 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.389180 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.447363 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.344168 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.315137 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.314200 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.336724 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.338902 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 1.04 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 1.01 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.910583 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.881565 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.791240 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.788728 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.826822 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.824226 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.577256 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.572538 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.483123 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.478221 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.449045 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.445913 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.455416 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.452294 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.408844 | 0.408844 | 0.408844 | 0.408844 | 6767.82 | 8583.85 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.389180 | 0.389180 | 0.389180 | 0.389180 | 6442.31 | 8218.76 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.447363 | 0.447363 | 0.447363 | 0.447363 | 7405.45 | 9764.39 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.344168 | 0.344168 | 0.344168 | 0.344168 | 5697.19 | 7383.17 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.315137 | 0.315137 | 0.315137 | 0.315137 | 5216.64 | 6844.21 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.314200 | 0.314200 | 0.314200 | 0.314200 | 5201.13 | 6826.83 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.336724 | 0.336724 | 0.336724 | 0.336724 | 5573.98 | 7245.00 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.338902 | 0.338902 | 0.338902 | 0.338902 | 5610.04 | 7285.43 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 1.04 | 1.04 | 1.04 | 1.04 | 17197.55 | 21274.96 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 1.01 | 1.01 | 1.01 | 1.01 | 16701.70 | 20718.54 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.910583 | 0.910583 | 0.910583 | 0.910583 | 15073.38 | 18892.76 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.881565 | 0.881565 | 0.881565 | 0.881565 | 14593.04 | 18353.78 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.791240 | 0.791240 | 0.791240 | 0.791240 | 13097.84 | 16676.68 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.788728 | 0.788728 | 0.788728 | 0.788728 | 13056.24 | 16630.03 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.826822 | 0.826822 | 0.826822 | 0.826822 | 13686.85 | 17337.50 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.824226 | 0.824226 | 0.824226 | 0.824226 | 13643.86 | 17289.29 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.577256 | 0.577256 | 0.577256 | 0.577256 | 9555.64 | 11710.77 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.572538 | 0.572538 | 0.572538 | 0.572538 | 9477.54 | 11623.00 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.483123 | 0.483123 | 0.483123 | 0.483123 | 7997.40 | 9963.22 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.478221 | 0.478221 | 0.478221 | 0.478221 | 7916.26 | 9872.06 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.449045 | 0.449045 | 0.449045 | 0.449045 | 7433.28 | 9330.18 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.445913 | 0.445913 | 0.445913 | 0.445913 | 7381.45 | 9272.06 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.455416 | 0.455416 | 0.455416 | 0.455416 | 7538.74 | 9448.61 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.452294 | 0.452294 | 0.452294 | 0.452294 | 7487.07 | 9390.66 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.408844 | 6767.82 | 0.800655 |
| SPLIT GNW COOLING COIL | 0.389180 | 6442.31 | 0.800655 |
| SPLIT OFFICE COOLING COIL | 0.447363 | 7405.45 | 0.800655 |
| SPLIT GNE COOLING COIL | 0.344168 | 5697.19 | 0.800655 |
| SPLIT GN1 COOLING COIL | 0.315137 | 5216.64 | 0.800655 |
| SPLIT GN2 COOLING COIL | 0.314200 | 5201.13 | 0.800655 |
| SPLIT GS1 COOLING COIL | 0.336724 | 5573.98 | 0.800655 |
| SPLIT GS2 COOLING COIL | 0.338902 | 5610.04 | 0.800655 |
| SPLIT MSW COOLING COIL | 1.04 | 17197.55 | 0.800655 |
| SPLIT MNW COOLING COIL | 1.01 | 16701.70 | 0.800655 |
| SPLIT MSE COOLING COIL | 0.910583 | 15073.38 | 0.800655 |
| SPLIT MNE COOLING COIL | 0.881565 | 14593.04 | 0.800655 |
| SPLIT MN1 COOLING COIL | 0.791240 | 13097.84 | 0.800655 |
| SPLIT MN2 COOLING COIL | 0.788728 | 13056.24 | 0.800655 |
| SPLIT MS1 COOLING COIL | 0.826822 | 13686.85 | 0.800655 |
| SPLIT MS2 COOLING COIL | 0.824226 | 13643.86 | 0.800655 |
| SPLIT TSW COOLING COIL | 0.577256 | 9555.64 | 0.800655 |
| SPLIT TNW COOLING COIL | 0.572538 | 9477.54 | 0.800655 |
| SPLIT TSE COOLING COIL | 0.483123 | 7997.40 | 0.800655 |
| SPLIT TNE COOLING COIL | 0.478221 | 7916.26 | 0.800655 |
| SPLIT TN1 COOLING COIL | 0.449045 | 7433.28 | 0.800655 |
| SPLIT TN2 COOLING COIL | 0.445913 | 7381.45 | 0.800655 |
| SPLIT TS1 COOLING COIL | 0.455416 | 7538.74 | 0.800655 |
| SPLIT TS2 COOLING COIL | 0.452294 | 7487.07 | 0.800655 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 8583.85 |
| SPLIT GNW HEATING COIL | 8218.76 |
| SPLIT OFFICE HEATING COIL | 9764.39 |
| SPLIT GNE HEATING COIL | 7383.17 |
| SPLIT GN1 HEATING COIL | 6844.21 |
| SPLIT GN2 HEATING COIL | 6826.83 |
| SPLIT GS1 HEATING COIL | 7245.00 |
| SPLIT GS2 HEATING COIL | 7285.43 |
| SPLIT MSW HEATING COIL | 21274.96 |
| SPLIT MNW HEATING COIL | 20718.54 |
| SPLIT MSE HEATING COIL | 18892.76 |
| SPLIT MNE HEATING COIL | 18353.78 |
| SPLIT MN1 HEATING COIL | 16676.68 |
| SPLIT MN2 HEATING COIL | 16630.03 |
| SPLIT MS1 HEATING COIL | 17337.50 |
| SPLIT MS2 HEATING COIL | 17289.29 |
| SPLIT TSW HEATING COIL | 11710.77 |
| SPLIT TNW HEATING COIL | 11623.00 |
| SPLIT TSE HEATING COIL | 9963.22 |
| SPLIT TNE HEATING COIL | 9872.06 |
| SPLIT TN1 HEATING COIL | 9330.18 |
| SPLIT TN2 HEATING COIL | 9272.06 |
| SPLIT TS1 HEATING COIL | 9448.61 |
| SPLIT TS2 HEATING COIL | 9390.66 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 7.10 | 3.00 | -1.00 | 0.80 | -0.20 | 4.80 | 6.10 | 13.70 | 22.20 | 22.70 | 21.70 | 18.50 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 | 39.72 | -104.75 | -7.00 | 1726.00 | 82237 | 0.9774 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 9.95 | 23.70 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 6.623E-005 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 3901.34220 | 4681.61064 | 0.34070 | 0.40884 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 2142.80598 | 2571.36718 | 0.11375 | 0.13650 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3717.63662 | 4461.16395 | 0.32432 | 0.38918 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 2008.85869 | 2410.63043 | 0.10664 | 0.12797 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4213.36390 | 5056.03668 | 0.37280 | 0.44736 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 25.76000 | 5.46288E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 2598.21115 | 3117.85338 | 0.13792 | 0.16551 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | -17.90000 | 9.55238E-004 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 3296.45921 | 3955.75106 | 0.28681 | 0.34417 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 2008.85867 | 2410.63040 | 0.10664 | 0.12797 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 3024.29448 | 3629.15337 | 0.26261 | 0.31514 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 1244.32442 | 1493.18930 | 6.60546E-002 | 7.92656E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 3015.53698 | 3618.64438 | 0.26183 | 0.31420 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 1244.32442 | 1493.18930 | 6.60546E-002 | 7.92656E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3226.74474 | 3872.09369 | 0.28060 | 0.33672 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 1380.23662 | 1656.28395 | 7.32688E-002 | 8.79226E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3247.11564 | 3896.53877 | 0.28242 | 0.33890 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 1388.47163 | 1666.16595 | 7.37060E-002 | 8.84472E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 9877.22905 | 11852.67486 | 0.86575 | 1.03890 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 3857.52943 | 4629.03532 | 0.20477 | 0.24572 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 9597.54889 | 11517.05867 | 0.84079 | 1.00895 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 3536.90562 | 4244.28674 | 0.18775 | 0.22530 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 8673.91802 | 10408.70162 | 0.75882 | 0.91058 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 3857.52939 | 4629.03527 | 0.20477 | 0.24572 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 8401.33978 | 10081.60774 | 0.73464 | 0.88157 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 3536.90557 | 4244.28668 | 0.18775 | 0.22530 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 7555.55231 | 9066.66278 | 0.65937 | 0.79124 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 1884.51610 | 2261.41932 | 0.10004 | 0.12005 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 7532.08121 | 9038.49745 | 0.65727 | 0.78873 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 1884.51609 | 2261.41931 | 0.10004 | 0.12005 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 7888.42691 | 9466.11229 | 0.68902 | 0.82682 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 2199.56648 | 2639.47978 | 0.11676 | 0.14011 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 7864.12711 | 9436.95253 | 0.68685 | 0.82423 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 2199.56648 | 2639.47977 | 0.11676 | 0.14011 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5480.97779 | 6577.17335 | 0.48105 | 0.57726 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 3325.51739 | 3990.62087 | 0.17652 | 0.21183 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 5436.63077 | 6523.95692 | 0.47712 | 0.57254 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 3149.81482 | 3779.77778 | 0.16720 | 0.20064 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4600.75312 | 5520.90374 | 0.40260 | 0.48312 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 3325.51736 | 3990.62084 | 0.17652 | 0.21183 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 4554.87213 | 5465.84656 | 0.39852 | 0.47822 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 3149.81479 | 3779.77775 | 0.16720 | 0.20064 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 4281.86485 | 5138.23782 | 0.37420 | 0.44904 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 2174.90865 | 2609.89037 | 0.11545 | 0.13854 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 4252.41224 | 5102.89469 | 0.37159 | 0.44591 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 2174.90864 | 2609.89037 | 0.11545 | 0.13854 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4342.01417 | 5210.41701 | 0.37951 | 0.45542 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 2351.53784 | 2821.84541 | 0.12483 | 0.14979 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4312.88599 | 5175.46319 | 0.37691 | 0.45229 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 28.12800 | 5.46644E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 2351.53784 | 2821.84540 | 0.12483 | 0.14979 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | -17.90000 | 9.55238E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4621.05 | 0.40884 | 0.40884 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 3528.10 | 0.13650 | 0.13650 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4402.75 | 0.38918 | 0.38918 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 3369.71 | 0.12797 | 0.12797 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 4971.69 | 0.44736 | 0.44736 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 4532.08 | 0.16551 | 0.16551 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 3902.34 | 0.34417 | 0.34417 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 3369.71 | 0.12797 | 0.12797 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3579.34 | 0.31514 | 0.31514 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 2465.63 | 7.92656E-002 | 7.92656E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3568.93 | 0.31420 | 0.31420 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 2465.63 | 7.92656E-002 | 7.92656E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 3819.67 | 0.33672 | 0.33672 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 2626.35 | 8.79226E-002 | 8.79226E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 3843.82 | 0.33890 | 0.33890 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 2636.09 | 8.84472E-002 | 8.84472E-002 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 11700.03 | 1.03890 | 1.03890 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 6549.95 | 0.24572 | 0.24572 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 11368.13 | 1.00895 | 1.00895 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 6170.82 | 0.22530 | 0.22530 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 10274.71 | 0.91058 | 0.91058 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 6549.95 | 0.24572 | 0.24572 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 9952.07 | 0.88157 | 0.88157 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 6170.82 | 0.22530 | 0.22530 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 8948.60 | 0.79124 | 0.79124 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 4216.86 | 0.12005 | 0.12005 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 8920.71 | 0.78873 | 0.78873 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 4216.86 | 0.12005 | 0.12005 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9343.82 | 0.82682 | 0.82682 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 4589.39 | 0.14011 | 0.14011 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9314.98 | 0.82423 | 0.82423 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 4589.39 | 0.14011 | 0.14011 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6492.02 | 0.57726 | 0.57726 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 4926.65 | 0.21183 | 0.21183 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 6439.64 | 0.57254 | 0.57254 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 4718.89 | 0.20064 | 0.20064 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 5448.29 | 0.48312 | 0.48312 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 4926.65 | 0.21183 | 0.21183 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 5393.94 | 0.47822 | 0.47822 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 4718.89 | 0.20064 | 0.20064 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 5070.26 | 0.44904 | 0.44904 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 3566.06 | 0.13854 | 0.13854 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 5035.45 | 0.44591 | 0.44591 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 3566.06 | 0.13854 | 0.13854 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5141.20 | 0.45542 | 0.45542 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 3774.92 | 0.14979 | 0.14979 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5106.62 | 0.45229 | 0.45229 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 3774.92 | 0.14979 | 0.14979 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.40884 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38918 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.44736 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34417 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31514 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31420 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33672 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33890 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.03890 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00895 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.91058 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.88157 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.79124 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.78873 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.82682 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.82423 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57726 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57254 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.48312 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.47822 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.44904 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.44591 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.45542 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.45229 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.40884 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.40884 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.40884 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.40884 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.40884 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.40884 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38918 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38918 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38918 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38918 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38918 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.38918 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.44736 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.44736 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.44736 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.44736 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.44736 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.44736 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34417 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34417 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34417 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34417 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34417 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.34417 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31514 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31514 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31514 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31514 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31514 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31514 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31420 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31420 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31420 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31420 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31420 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31420 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33672 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33672 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33672 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33672 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33672 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.33672 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33890 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33890 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33890 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33890 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33890 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.33890 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.03890 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.03890 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.03890 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 1.03890 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.03890 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 1.03890 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00895 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00895 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00895 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00895 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00895 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 1.00895 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.91058 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.91058 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.91058 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.91058 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.91058 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.91058 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.88157 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.88157 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.88157 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.88157 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.88157 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.88157 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.79124 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.79124 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.79124 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.79124 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.79124 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.79124 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.78873 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.78873 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.78873 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.78873 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.78873 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.78873 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.82682 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.82682 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.82682 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.82682 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.82682 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.82682 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.82423 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.82423 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.82423 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.82423 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.82423 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.82423 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57726 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57726 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57726 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57726 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57726 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.57726 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57254 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57254 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57254 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57254 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57254 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.57254 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.48312 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.48312 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.48312 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.48312 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.48312 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.48312 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.47822 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.47822 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.47822 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.47822 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.47822 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.47822 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.44904 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.44904 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.44904 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.44904 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.44904 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.44904 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.44591 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.44591 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.44591 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.44591 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.44591 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.44591 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.45542 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.45542 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.45542 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.45542 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.45542 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.45542 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.45229 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.45229 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.45229 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.45229 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.45229 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.45229 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.40884 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.38918 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.44736 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.34417 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.31514 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.31420 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.33672 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.33890 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 1.03890 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 1.00895 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.91058 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.88157 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.79124 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.78873 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.82682 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.82423 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.57726 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.57254 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.48312 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.47822 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.44904 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.44591 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.45542 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.45229 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.40884 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.40884 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.40884 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.40884 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.40884 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6767.81971 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8583.85426 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.40884 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.40884 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6767.81971 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 8583.85426 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38918 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38918 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38918 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38918 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38918 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6442.30918 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8218.76477 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38918 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38918 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6442.30918 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 8218.76477 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.44736 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.44736 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.44736 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.44736 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.44736 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7405.44565 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9764.38751 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.44736 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44736 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7405.44565 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 9764.38751 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34417 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34417 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34417 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34417 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34417 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5697.19436 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7383.17338 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34417 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34417 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5697.19436 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 7383.17338 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31514 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31514 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31514 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31514 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31514 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5216.63693 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6844.21466 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31514 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31514 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5216.63693 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 6844.21466 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31420 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31420 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31420 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31420 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31420 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5201.13341 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6826.82877 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31420 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31420 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5201.13341 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 6826.82877 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33672 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33672 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33672 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33672 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33672 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5573.98407 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7245.00040 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33672 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33672 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5573.98407 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 7245.00040 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33890 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33890 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33890 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33890 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33890 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5610.03818 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7285.43239 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33890 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33890 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5610.03818 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 7285.43239 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.03890 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.03890 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.03890 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.03890 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.03890 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 17197.55428 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 21274.96302 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 1.03890 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 1.03890 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 17197.55428 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 21274.96302 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00895 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00895 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00895 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00895 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.00895 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 16701.69677 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20718.54220 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 1.00895 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 1.00895 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 16701.69677 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 20718.54220 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.91058 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.91058 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.91058 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.91058 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.91058 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 15073.38431 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18892.75968 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.91058 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.91058 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 15073.38431 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 18892.75968 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.88157 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.88157 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.88157 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.88157 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.88157 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14593.03765 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18353.77770 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.88157 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.88157 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14593.03765 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 18353.77770 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.79124 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.79124 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.79124 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.79124 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.79124 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13097.83773 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16676.68125 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.79124 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.79124 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13097.83773 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 16676.68125 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.78873 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.78873 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.78873 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.78873 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.78873 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13056.24119 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16630.03366 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.78873 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.78873 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13056.24119 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 16630.03366 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.82682 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.82682 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.82682 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.82682 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.82682 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13686.84664 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17337.49889 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.82682 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.82682 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13686.84664 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 17337.49889 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.82423 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.82423 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.82423 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.82423 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.82423 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13643.86252 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17289.29426 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.82423 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.82423 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13643.86252 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 17289.29426 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57726 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57726 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57726 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57726 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57726 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9555.63562 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11710.77466 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57726 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57726 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9555.63562 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 11710.77466 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57254 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57254 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57254 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57254 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57254 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9477.54244 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11623.00262 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57254 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57254 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9477.54244 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 11623.00262 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.48312 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.48312 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.48312 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.48312 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.48312 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7997.39985 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9963.21812 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.48312 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.48312 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7997.39985 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 9963.21812 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.47822 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.47822 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.47822 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.47822 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.47822 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7916.25678 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9872.05856 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.47822 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.47822 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7916.25678 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 9872.05856 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.44904 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.44904 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.44904 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.44904 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.44904 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7433.28113 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9330.18242 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.44904 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44904 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7433.28113 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 9330.18242 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.44591 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.44591 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.44591 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.44591 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.44591 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7381.45074 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9272.05761 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.44591 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44591 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7381.45074 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 9272.05761 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.45542 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.45542 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.45542 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.45542 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.45542 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7538.74430 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9448.61101 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.45542 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.45542 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7538.74430 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 9448.61101 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.45229 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.45229 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.45229 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.45229 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.45229 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7487.06856 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9390.65847 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.45229 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.45229 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7487.06856 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 9390.65847 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 6447.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 6137.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 7054.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 5427.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 4969.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 4954.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 5310.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 5344.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 16383.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 15911.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 14359.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 13902.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 12477.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 12438.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 13038.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 12997.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 9103.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 9028.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 7618.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 7541.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 7081.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 7032.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 7181.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 7132.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 4.061E-002 | 4.021E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3863802970E-002 | 3.5741524311E-002 | Pass | Pass | 0.1487219246 | 0.5306423453 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7936064102E-007 | 1.5166602929E-006 | Pass | Pass | 3.2710540532E-002 | 4.5089769918E-002 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 4.6921599211E-002 | 5.5460762995E-002 | Pass | Pass | 0.2504095382 | 2.1436660139 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.8314603483E-007 | 8.0802560530E-007 | Pass | Pass | 2.7635589452E-002 | 3.4864621850E-002 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0162516426E-007 | 5.7655098260E-007 | Pass | Pass | 6.1777104573E-002 | 0.1973435764 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 9.9690332285E-008 | 5.6120102754E-007 | Pass | Pass | 6.0183242099E-002 | 0.1834475714 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.1403092985E-002 | 3.8142364073E-002 | Pass | Pass | 1.9231812697E-002 | 1.9986728061E-002 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.9529088551E-002 | 3.7903806776E-002 | Pass | Pass | 2.1102696587E-002 | 2.2790586774E-002 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0273464463E-002 | 4.6771188386E-002 | Pass | Pass | 3.1140459990E-002 | 3.8135961297E-002 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0896490737E-007 | 5.1601902859E-007 | Pass | Pass | 0.1407448827 | 0.2684043229 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0296706972E-002 | 5.8081467545E-002 | Pass | Pass | 2.8574347222E-002 | 3.1936312705E-002 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 9.8935386969E-008 | 6.0561017447E-007 | Pass | Pass | 0.2438397806 | 0.5400076399 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.2007822060E-007 | 5.2610590353E-007 | Pass | Pass | 0.9956875948 | 6.3123600093 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.2194056377E-007 | 5.3640522273E-007 | Pass | Pass | 0.4122334195 | 1.5069816849 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.8370743357E-002 | 4.3452981415E-002 | Pass | Pass | 2.2434552351E-002 | 2.6937215176E-002 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.8346599270E-002 | 4.3661990557E-002 | Pass | Pass | 2.2491082812E-002 | 2.6645665866E-002 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0385279392E-002 | 7.0816040468E-002 | Pass | Pass | 0.2399396711 | 1.4506595571 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.2234207837E-007 | 2.3102544882E-006 | Pass | Pass | 0.1145787428 | 0.4013631745 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0278712329E-002 | 8.0989063088E-002 | Pass | Pass | 0.1438902494 | 0.4624441889 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.1449623983E-007 | 8.4435130502E-007 | Pass | Pass | 4.3954736038E-002 | 6.5641432348E-002 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.0495705878E-007 | 1.0985805628E-006 | Pass | Pass | 4.9816792862E-002 | 6.6067906240E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9985359372E-007 | 1.0535258085E-006 | Pass | Pass | 4.9386745828E-002 | 6.1883853247E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0577202547E-002 | 7.2704328993E-002 | Pass | Pass | 0.1598290326 | 0.7047789902 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0408749169E-002 | 7.3220034030E-002 | Pass | Pass | 0.1899099680 | 1.0460210630 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 3.8561221403E-002 | 2.4498716286E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.2338464430 | 0.7681637257 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 1.1711926264E-002 | 7.4970972724E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 2228.96 | 133.30 | 0.00 | 16.05 | 582.14 | 2960.45 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00 | -17.90 | Wetbulb [C] | 2.50 | 180.00 |
| DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 14.80 | 15.00 | Wetbulb [C] | 3.60 | 30.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 11.00 | 10 | |||
| Feb | 15.00 | 16 | |||
| Mar | 88.00 | 32 | |||
| Apr | 159.00 | 54 | |||
| May | 30.00 | 24 | |||
| Jun | 11.00 | 4 | |||
| Jul | 167.00 | 26 | |||
| Aug | 33.00 | 24 | |||
| Sep | 8.00 | 8 | |||
| Oct | 13.00 | 10 | |||
| Nov | 12.00 | 22 | |||
| Dec | 11.00 | 18 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.30 | 0.221 | 0.228 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.040 | 0.041 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.3972_SHGC_0.4 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.257 | 0.401 | 0.402 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.3972_SHGC_0.4 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.257 | 0.401 | 0.402 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.3972_SHGC_0.4 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.257 | 0.401 | 0.402 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 2.257 | 0.401 | 0.402 | |||||||||||||||||
| North Total or Average | 112.97 | 2.257 | 0.401 | 0.402 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 2.257 | 0.401 | 0.402 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.67 | 83.67 | 50.00 | |
| Exterior Lighting Total | 3183.33 | 50.00 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6767.82 | 5418.69 | 1349.13 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6442.31 | 5158.07 | 1284.24 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7405.45 | 5929.21 | 1476.24 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5697.19 | 4561.49 | 1135.71 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5216.64 | 4176.73 | 1039.91 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5201.13 | 4164.31 | 1036.82 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5573.98 | 4462.84 | 1111.14 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5610.04 | 4491.71 | 1118.33 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 17197.55 | 13769.31 | 3428.24 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 16701.70 | 13372.30 | 3329.40 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 15073.38 | 12068.58 | 3004.80 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14593.04 | 11683.99 | 2909.05 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13097.84 | 10486.85 | 2610.99 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13056.24 | 10453.55 | 2602.69 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13686.85 | 10958.45 | 2728.40 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13643.86 | 10924.03 | 2719.83 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9555.64 | 7650.77 | 1904.87 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9477.54 | 7588.24 | 1889.30 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7997.40 | 6403.16 | 1594.24 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7916.26 | 6338.19 | 1578.06 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7433.28 | 5951.50 | 1481.79 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7381.45 | 5910.00 | 1471.45 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7538.74 | 6035.94 | 1502.81 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7487.07 | 5994.56 | 1492.51 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 6447.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNW COOLING COIL | 6137.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT OFFICE COOLING COIL | 7054.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNE COOLING COIL | 5427.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN1 COOLING COIL | 4969.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN2 COOLING COIL | 4954.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS1 COOLING COIL | 5310.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS2 COOLING COIL | 5344.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSW COOLING COIL | 16383.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNW COOLING COIL | 15911.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSE COOLING COIL | 14359.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNE COOLING COIL | 13902.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN1 COOLING COIL | 12477.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN2 COOLING COIL | 12438.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS1 COOLING COIL | 13038.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS2 COOLING COIL | 12997.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSW COOLING COIL | 9103.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNW COOLING COIL | 9028.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSE COOLING COIL | 7618.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNE COOLING COIL | 7541.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN1 COOLING COIL | 7081.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN2 COOLING COIL | 7032.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS1 COOLING COIL | 7181.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS2 COOLING COIL | 7132.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 8583.85 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 8218.76 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 9764.39 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 7383.17 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 6844.21 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 6826.83 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 7245.00 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 7285.43 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 21274.96 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 20718.54 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 18892.76 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 18353.78 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 16676.68 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 16630.03 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 17337.50 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 17289.29 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 11710.77 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 11623.00 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 9963.22 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 9872.06 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 9330.18 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 9272.06 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 9448.61 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 9390.66 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 457.95 | 1120.11 | 1.00 | 1.70 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 435.92 | 1120.11 | 1.00 | 1.73 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 501.09 | 1120.11 | 1.00 | 1.66 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 385.50 | 1120.11 | 1.00 | 1.80 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 352.99 | 1120.11 | 1.00 | 1.86 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 351.94 | 1120.11 | 1.00 | 1.86 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 377.17 | 1120.11 | 1.00 | 1.82 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 379.61 | 1120.11 | 1.00 | 1.81 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 1.04 | 1163.68 | 1120.11 | 1.00 | 1.36 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 1.01 | 1130.13 | 1120.11 | 1.00 | 1.37 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.91 | 1019.95 | 1120.11 | 1.00 | 1.40 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.88 | 987.45 | 1120.11 | 1.00 | 1.41 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.79 | 886.27 | 1120.11 | 1.00 | 1.44 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.79 | 883.46 | 1120.11 | 1.00 | 1.44 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.83 | 926.13 | 1120.11 | 1.00 | 1.42 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.82 | 923.22 | 1120.11 | 1.00 | 1.42 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 646.59 | 1120.11 | 1.00 | 1.55 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.57 | 641.30 | 1120.11 | 1.00 | 1.55 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.48 | 541.15 | 1120.11 | 1.00 | 1.62 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.48 | 535.66 | 1120.11 | 1.00 | 1.63 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 502.98 | 1120.11 | 1.00 | 1.66 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 499.47 | 1120.11 | 1.00 | 1.66 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.46 | 510.11 | 1120.11 | 1.00 | 1.65 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 506.62 | 1120.11 | 1.00 | 1.65 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 3901.34 | 4681.61 | 53.05 | 0.341 | 0.409 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00805 | 28.13 | 0.00547 | 0.026 | 0.00 |
| G NW APARTMENT | 3717.64 | 4461.16 | 50.55 | 0.324 | 0.389 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 28.13 | 0.00547 | 0.026 | 0.00 |
| OFFICE | 4213.36 | 5056.04 | 57.29 | 0.373 | 0.447 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.90 | 23.90 | 0.00794 | 25.76 | 0.00546 | 0.038 | 0.00 |
| G NE APARTMENT | 3296.46 | 3955.75 | 44.82 | 0.287 | 0.344 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 28.13 | 0.00547 | 0.026 | 0.00 |
| G N1 APARTMENT | 3024.29 | 3629.15 | 41.12 | 0.263 | 0.315 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00806 | 28.13 | 0.00547 | 0.026 | 0.00 |
| G N2 APARTMENT | 3015.54 | 3618.64 | 41.00 | 0.262 | 0.314 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00806 | 28.13 | 0.00547 | 0.026 | 0.00 |
| G S1 APARTMENT | 3226.74 | 3872.09 | 43.88 | 0.281 | 0.337 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 28.13 | 0.00547 | 0.026 | 0.00 |
| G S2 APARTMENT | 3247.12 | 3896.54 | 44.15 | 0.282 | 0.339 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 28.13 | 0.00547 | 0.026 | 0.00 |
| M SW APARTMENT | 9877.23 | 11852.67 | 134.31 | 0.866 | 1.039 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00801 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M NW APARTMENT | 9597.55 | 11517.06 | 130.51 | 0.841 | 1.009 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M SE APARTMENT | 8673.92 | 10408.70 | 117.95 | 0.759 | 0.911 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00802 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M NE APARTMENT | 8401.34 | 10081.61 | 114.24 | 0.735 | 0.882 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M N1 APARTMENT | 7555.55 | 9066.66 | 102.74 | 0.659 | 0.791 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M N2 APARTMENT | 7532.08 | 9038.50 | 102.42 | 0.657 | 0.789 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M S1 APARTMENT | 7888.43 | 9466.11 | 107.27 | 0.689 | 0.827 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00805 | 28.13 | 0.00547 | 0.052 | 0.00 |
| M S2 APARTMENT | 7864.13 | 9436.95 | 106.94 | 0.687 | 0.824 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00805 | 28.13 | 0.00547 | 0.052 | 0.00 |
| T SW APARTMENT | 5480.98 | 6577.17 | 74.53 | 0.481 | 0.577 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T NW APARTMENT | 5436.63 | 6523.96 | 73.93 | 0.477 | 0.573 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00799 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T SE APARTMENT | 4600.75 | 5520.90 | 62.56 | 0.403 | 0.483 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T NE APARTMENT | 4554.87 | 5465.85 | 61.94 | 0.399 | 0.478 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00798 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T N1 APARTMENT | 4281.86 | 5138.24 | 58.22 | 0.374 | 0.449 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00802 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T N2 APARTMENT | 4252.41 | 5102.89 | 57.82 | 0.372 | 0.446 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00802 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T S1 APARTMENT | 4342.01 | 5210.42 | 59.04 | 0.380 | 0.455 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 28.13 | 0.00547 | 0.026 | 0.00 |
| T S2 APARTMENT | 4312.89 | 5175.46 | 58.65 | 0.377 | 0.452 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 28.13 | 0.00547 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 2142.81 | 2571.37 | 29.14 | 0.114 | 0.136 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | 21.10 | 21.10 | 0.00769 | -17.90 | 0.00096 | 0.026 | 0.00 |
| G NW APARTMENT | 2008.86 | 2410.63 | 27.32 | 0.107 | 0.128 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00777 | -17.90 | 0.00096 | 0.026 | 0.00 |
| OFFICE | 2598.21 | 3117.85 | 35.33 | 0.138 | 0.166 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | 21.10 | 21.10 | 0.00774 | -17.90 | 0.00096 | 0.038 | 0.00 |
| G NE APARTMENT | 2008.86 | 2410.63 | 27.32 | 0.107 | 0.128 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00777 | -17.90 | 0.00096 | 0.026 | 0.00 |
| G N1 APARTMENT | 1244.32 | 1493.19 | 16.92 | 0.066 | 0.079 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00786 | -17.90 | 0.00096 | 0.026 | 0.00 |
| G N2 APARTMENT | 1244.32 | 1493.19 | 16.92 | 0.066 | 0.079 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00786 | -17.90 | 0.00096 | 0.026 | 0.00 |
| G S1 APARTMENT | 1380.24 | 1656.28 | 18.77 | 0.073 | 0.088 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | 21.10 | 21.10 | 0.00770 | -17.90 | 0.00096 | 0.026 | 0.00 |
| G S2 APARTMENT | 1388.47 | 1666.17 | 18.88 | 0.074 | 0.088 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | 21.10 | 21.10 | 0.00770 | -17.90 | 0.00096 | 0.026 | 0.00 |
| M SW APARTMENT | 3857.53 | 4629.04 | 52.45 | 0.205 | 0.246 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00752 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M NW APARTMENT | 3536.91 | 4244.29 | 48.09 | 0.188 | 0.225 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00765 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M SE APARTMENT | 3857.53 | 4629.04 | 52.45 | 0.205 | 0.246 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00752 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M NE APARTMENT | 3536.91 | 4244.29 | 48.09 | 0.188 | 0.225 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00765 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M N1 APARTMENT | 1884.52 | 2261.42 | 25.63 | 0.100 | 0.120 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00773 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M N2 APARTMENT | 1884.52 | 2261.42 | 25.63 | 0.100 | 0.120 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00773 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M S1 APARTMENT | 2199.57 | 2639.48 | 29.91 | 0.117 | 0.140 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00750 | -17.90 | 0.00096 | 0.052 | 0.00 |
| M S2 APARTMENT | 2199.57 | 2639.48 | 29.91 | 0.117 | 0.140 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00750 | -17.90 | 0.00096 | 0.052 | 0.00 |
| T SW APARTMENT | 3325.52 | 3990.62 | 45.22 | 0.177 | 0.212 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00763 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T NW APARTMENT | 3149.81 | 3779.78 | 42.83 | 0.167 | 0.201 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00771 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T SE APARTMENT | 3325.52 | 3990.62 | 45.22 | 0.177 | 0.212 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00763 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T NE APARTMENT | 3149.81 | 3779.78 | 42.83 | 0.167 | 0.201 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00771 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T N1 APARTMENT | 2174.91 | 2609.89 | 29.57 | 0.115 | 0.139 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00780 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T N2 APARTMENT | 2174.91 | 2609.89 | 29.57 | 0.115 | 0.139 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00780 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T S1 APARTMENT | 2351.54 | 2821.85 | 31.98 | 0.125 | 0.150 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00768 | -17.90 | 0.00096 | 0.026 | 0.00 |
| T S2 APARTMENT | 2351.54 | 2821.85 | 31.98 | 0.125 | 0.150 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21.10 | 21.10 | 0.00768 | -17.90 | 0.00096 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.41 | 0.41 | 0.14 | 0.14 | 0.4088 | 0.4088 | 0.4088 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.39 | 0.39 | 0.13 | 0.13 | 0.3892 | 0.3892 | 0.3892 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.45 | 0.45 | 0.17 | 0.17 | 0.4474 | 0.4474 | 0.4474 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.34 | 0.34 | 0.13 | 0.13 | 0.3442 | 0.3442 | 0.3442 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.32 | 0.32 | 0.08 | 0.08 | 0.3151 | 0.3151 | 0.3151 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.31 | 0.31 | 0.08 | 0.08 | 0.3142 | 0.3142 | 0.3142 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.34 | 0.34 | 0.09 | 0.09 | 0.3367 | 0.3367 | 0.3367 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.34 | 0.34 | 0.09 | 0.09 | 0.3389 | 0.3389 | 0.3389 | 1.0000 | 1.0000 |
| SPLIT MSW | 1.04 | 1.04 | 0.25 | 0.25 | 1.0389 | 1.0389 | 1.0389 | 1.0000 | 1.0000 |
| SPLIT MNW | 1.01 | 1.01 | 0.23 | 0.23 | 1.0089 | 1.0089 | 1.0089 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.91 | 0.91 | 0.25 | 0.25 | 0.9106 | 0.9106 | 0.9106 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.88 | 0.88 | 0.23 | 0.23 | 0.8816 | 0.8816 | 0.8816 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.79 | 0.79 | 0.12 | 0.12 | 0.7912 | 0.7912 | 0.7912 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.79 | 0.79 | 0.12 | 0.12 | 0.7887 | 0.7887 | 0.7887 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.83 | 0.83 | 0.14 | 0.14 | 0.8268 | 0.8268 | 0.8268 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.82 | 0.82 | 0.14 | 0.14 | 0.8242 | 0.8242 | 0.8242 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.58 | 0.58 | 0.21 | 0.21 | 0.5773 | 0.5773 | 0.5773 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.57 | 0.57 | 0.20 | 0.20 | 0.5725 | 0.5725 | 0.5725 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.48 | 0.48 | 0.21 | 0.21 | 0.4831 | 0.4831 | 0.4831 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.48 | 0.48 | 0.20 | 0.20 | 0.4782 | 0.4782 | 0.4782 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.45 | 0.45 | 0.14 | 0.14 | 0.4490 | 0.4490 | 0.4490 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.45 | 0.45 | 0.14 | 0.14 | 0.4459 | 0.4459 | 0.4459 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.46 | 0.46 | 0.15 | 0.15 | 0.4554 | 0.4554 | 0.4554 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.45 | 0.45 | 0.15 | 0.15 | 0.4523 | 0.4523 | 0.4523 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6767.820 | 5418.690 | 0.408844 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6268.81 | 6268.81 | 0.408844 | 25.43 | 14.23 | 0.00788206 | 12.80 | 9.62 | 0.00788206 | 28.13 | 0.00546644 | 13.13 | 6.3483 | 24.00 | 0.00804581 | 35.1822 | 3901.34 | 0.00 | 6766.67 | 4886.48 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 8583.854 | 8583.854 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | 8583.85 | 8583.85 | 0.408844 | 18.62 | 11.28 | 0.00725970 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 6.3483 | 21.10 | 0.00768706 | 40.1120 | 2142.81 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 6442.309 | 5158.069 | 0.389180 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5964.81 | 5964.81 | 0.389180 | 25.44 | 14.21 | 0.00785666 | 12.80 | 9.60 | 0.00785666 | 28.13 | 0.00546644 | 13.13 | 6.6690 | 24.00 | 0.00802746 | 35.1027 | 3717.64 | 0.00 | 6441.21 | 4651.45 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 8218.765 | 8218.765 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 8218.76 | 8218.76 | 0.389180 | 18.50 | 11.29 | 0.00731527 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 6.6690 | 21.10 | 0.00776973 | 40.5373 | 2008.86 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 7405.446 | 5929.209 | 0.447363 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 6938.84 | 6938.84 | 0.447363 | 25.24 | 14.04 | 0.00773300 | 12.80 | 9.48 | 0.00773300 | 25.76 | 0.00546288 | 12.29 | 8.5179 | 23.90 | 0.00795733 | 35.0090 | 3964.55 | 0.00 | 7404.19 | 5346.86 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 9764.388 | 9764.388 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | 9764.39 | 9764.39 | 0.447363 | 17.78 | 10.88 | 0.00716428 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 8.5179 | 21.10 | 0.00774240 | 40.3972 | 2598.21 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 5697.194 | 4561.489 | 0.344168 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5273.98 | 5273.98 | 0.344168 | 25.47 | 14.20 | 0.00783692 | 12.80 | 9.58 | 0.00783692 | 28.13 | 0.00546644 | 13.13 | 7.5413 | 24.00 | 0.00803026 | 35.1148 | 3296.46 | 0.00 | 5696.22 | 4113.47 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 7383.173 | 7383.173 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 7383.17 | 7383.17 | 0.344168 | 18.16 | 11.10 | 0.00725584 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 7.5413 | 21.10 | 0.00776973 | 40.5373 | 2008.86 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 5216.637 | 4176.728 | 0.315137 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4831.17 | 4831.17 | 0.315137 | 25.49 | 14.22 | 0.00785021 | 12.80 | 9.59 | 0.00785021 | 28.13 | 0.00546644 | 13.13 | 8.2360 | 24.00 | 0.00806416 | 35.2613 | 3024.29 | 0.00 | 5215.75 | 3766.50 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 6844.215 | 6844.215 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 6844.21 | 6844.21 | 0.315137 | 17.89 | 11.04 | 0.00729395 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 8.2360 | 21.10 | 0.00786286 | 41.0166 | 1244.32 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 5201.133 | 4164.315 | 0.314200 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4816.80 | 4816.80 | 0.314200 | 25.49 | 14.22 | 0.00784978 | 12.80 | 9.59 | 0.00784978 | 28.13 | 0.00546644 | 13.13 | 8.2605 | 24.00 | 0.00806438 | 35.2623 | 3015.54 | 0.00 | 5200.25 | 3755.31 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 6826.829 | 6826.829 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 6826.83 | 6826.83 | 0.314200 | 17.88 | 11.03 | 0.00729226 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 8.2605 | 21.10 | 0.00786286 | 41.0166 | 1244.32 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5573.984 | 4462.840 | 0.336724 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5166.44 | 5166.44 | 0.336724 | 25.47 | 14.25 | 0.00789874 | 12.80 | 9.64 | 0.00789874 | 28.13 | 0.00546644 | 13.13 | 7.7080 | 24.00 | 0.00810188 | 35.4247 | 3226.74 | 0.00 | 5573.04 | 4024.51 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 7245.000 | 7245.000 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | 7245.00 | 7245.00 | 0.336724 | 18.09 | 11.01 | 0.00717935 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 7.7080 | 21.10 | 0.00769916 | 40.1738 | 1380.24 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5610.038 | 4491.707 | 0.338902 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5199.87 | 5199.87 | 0.338902 | 25.47 | 14.25 | 0.00789952 | 12.80 | 9.64 | 0.00789952 | 28.13 | 0.00546644 | 13.13 | 7.6584 | 24.00 | 0.00810131 | 35.4222 | 3247.12 | 0.00 | 5609.08 | 4050.54 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 7285.432 | 7285.432 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | 7285.43 | 7285.43 | 0.338902 | 18.11 | 11.02 | 0.00718432 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 7.6584 | 21.10 | 0.00770093 | 40.1829 | 1388.47 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 17197.554 | 13769.312 | 1.038904 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 15925.54 | 15925.54 | 1.038904 | 25.39 | 14.22 | 0.00788642 | 12.80 | 9.63 | 0.00788642 | 28.13 | 0.00546644 | 13.13 | 4.9965 | 24.00 | 0.00801369 | 35.0432 | 19754.46 | 0.00 | 17194.63 | 12416.92 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 21274.963 | 21274.963 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 21274.96 | 21274.96 | 1.038904 | 19.15 | 11.42 | 0.00719558 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 4.9965 | 21.10 | 0.00752378 | 39.2712 | 7715.06 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 16701.697 | 13372.301 | 1.008950 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 15463.10 | 15463.10 | 1.008950 | 25.40 | 14.21 | 0.00787352 | 12.80 | 9.62 | 0.00787352 | 28.13 | 0.00546644 | 13.13 | 5.1449 | 24.00 | 0.00800407 | 35.0015 | 19195.10 | 0.00 | 16698.85 | 12058.90 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 20718.542 | 20718.542 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 20718.54 | 20718.54 | 1.008950 | 19.09 | 11.50 | 0.00730846 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.1449 | 21.10 | 0.00765305 | 39.9369 | 7073.81 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 15073.384 | 12068.584 | 0.910583 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 13957.28 | 13957.28 | 0.910583 | 25.41 | 14.21 | 0.00787297 | 12.80 | 9.62 | 0.00787297 | 28.13 | 0.00546644 | 13.13 | 5.7006 | 24.00 | 0.00801845 | 35.0638 | 17347.84 | 0.00 | 15070.82 | 10883.23 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 18892.760 | 18892.760 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 18892.76 | 18892.76 | 0.910583 | 18.88 | 11.28 | 0.00714933 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.7006 | 21.10 | 0.00752378 | 39.2712 | 7715.06 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 14593.038 | 11683.992 | 0.881565 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 13508.17 | 13508.17 | 0.881565 | 25.42 | 14.20 | 0.00785449 | 12.80 | 9.60 | 0.00785449 | 28.13 | 0.00546644 | 13.13 | 5.8883 | 24.00 | 0.00800390 | 35.0007 | 16802.68 | 0.00 | 14590.55 | 10536.42 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 18353.778 | 18353.778 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 18353.78 | 18353.78 | 0.881565 | 18.80 | 11.35 | 0.00725867 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.8883 | 21.10 | 0.00765305 | 39.9369 | 7073.81 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 13097.838 | 10486.853 | 0.791240 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12128.95 | 12128.95 | 0.791240 | 25.44 | 14.22 | 0.00786602 | 12.80 | 9.61 | 0.00786602 | 28.13 | 0.00546644 | 13.13 | 6.5605 | 24.00 | 0.00803450 | 35.1331 | 15111.10 | 0.00 | 13095.61 | 9456.86 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 16676.681 | 16676.681 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 16676.68 | 16676.68 | 0.791240 | 18.54 | 11.28 | 0.00728890 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 6.5605 | 21.10 | 0.00773359 | 40.3510 | 3769.03 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 13056.241 | 10453.548 | 0.788728 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12090.39 | 12090.39 | 0.788728 | 25.44 | 14.22 | 0.00786559 | 12.80 | 9.61 | 0.00786559 | 28.13 | 0.00546644 | 13.13 | 6.5814 | 24.00 | 0.00803461 | 35.1336 | 15064.16 | 0.00 | 13054.02 | 9426.82 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 16630.034 | 16630.034 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 16630.03 | 16630.03 | 0.788728 | 18.53 | 11.27 | 0.00728748 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 6.5814 | 21.10 | 0.00773359 | 40.3510 | 3769.03 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 13686.847 | 10958.446 | 0.826822 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12679.97 | 12679.97 | 0.826822 | 25.43 | 14.23 | 0.00789194 | 12.80 | 9.63 | 0.00789194 | 28.13 | 0.00546644 | 13.13 | 6.2781 | 24.00 | 0.00805442 | 35.2194 | 15776.85 | 0.00 | 13684.52 | 9882.13 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 17337.499 | 17337.499 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 17337.50 | 17337.50 | 0.826822 | 18.65 | 11.13 | 0.00708490 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 6.2781 | 21.10 | 0.00749551 | 39.1244 | 4399.13 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 13643.863 | 10924.030 | 0.824226 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12640.16 | 12640.16 | 0.824226 | 25.43 | 14.23 | 0.00789175 | 12.80 | 9.63 | 0.00789175 | 28.13 | 0.00546644 | 13.13 | 6.2979 | 24.00 | 0.00805477 | 35.2209 | 15728.25 | 0.00 | 13641.54 | 9851.10 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 17289.294 | 17289.294 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 17289.29 | 17289.29 | 0.824226 | 18.64 | 11.13 | 0.00708361 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 6.2979 | 21.10 | 0.00749551 | 39.1244 | 4399.13 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 9555.636 | 7650.770 | 0.577256 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 8846.91 | 8846.91 | 0.577256 | 25.37 | 14.21 | 0.00788180 | 12.80 | 9.62 | 0.00788180 | 28.13 | 0.00546644 | 13.13 | 4.4962 | 24.00 | 0.00799551 | 34.9645 | 5480.98 | 0.00 | 9554.01 | 6899.33 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 11710.775 | 11710.775 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 11710.77 | 11710.77 | 0.577256 | 19.35 | 11.61 | 0.00732905 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 4.4962 | 21.10 | 0.00762912 | 39.8153 | 3325.52 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 9477.542 | 7588.244 | 0.572538 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 8773.21 | 8773.21 | 0.572538 | 25.38 | 14.20 | 0.00787328 | 12.80 | 9.62 | 0.00787328 | 28.13 | 0.00546644 | 13.13 | 4.5332 | 24.00 | 0.00798756 | 34.9301 | 5436.63 | 0.00 | 9475.93 | 6842.94 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 11623.003 | 11623.003 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 11623.00 | 11623.00 | 0.572538 | 19.33 | 11.67 | 0.00740028 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 4.5332 | 21.10 | 0.00770632 | 40.2123 | 3149.81 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 7997.400 | 6403.160 | 0.483123 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7403.00 | 7403.00 | 0.483123 | 25.41 | 14.20 | 0.00786040 | 12.80 | 9.60 | 0.00786040 | 28.13 | 0.00546644 | 13.13 | 5.3722 | 24.00 | 0.00799632 | 34.9680 | 4600.75 | 0.00 | 7996.04 | 5774.26 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 9963.218 | 9963.218 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 9963.22 | 9963.22 | 0.483123 | 19.00 | 11.43 | 0.00727059 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.3722 | 21.10 | 0.00762912 | 39.8153 | 3325.52 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 7916.257 | 6338.193 | 0.478221 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7326.22 | 7326.22 | 0.478221 | 25.41 | 14.19 | 0.00784810 | 12.80 | 9.59 | 0.00784810 | 28.13 | 0.00546644 | 13.13 | 5.4273 | 24.00 | 0.00798478 | 34.9180 | 4554.87 | 0.00 | 7914.91 | 5715.67 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 9872.059 | 9872.059 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 9872.06 | 9872.06 | 0.478221 | 18.98 | 11.49 | 0.00733992 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.4273 | 21.10 | 0.00770632 | 40.2123 | 3149.81 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 7433.281 | 5951.496 | 0.449045 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6882.97 | 6882.97 | 0.449045 | 25.42 | 14.21 | 0.00787043 | 12.80 | 9.61 | 0.00787043 | 28.13 | 0.00546644 | 13.13 | 5.7800 | 24.00 | 0.00801791 | 35.0614 | 4281.86 | 0.00 | 7432.02 | 5366.95 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 9330.182 | 9330.182 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 9330.18 | 9330.18 | 0.449045 | 18.85 | 11.49 | 0.00740208 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.7800 | 21.10 | 0.00779756 | 40.6811 | 2174.91 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 7381.451 | 5909.997 | 0.445913 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6834.92 | 6834.92 | 0.445913 | 25.42 | 14.21 | 0.00786951 | 12.80 | 9.61 | 0.00786951 | 28.13 | 0.00546644 | 13.13 | 5.8205 | 24.00 | 0.00801803 | 35.0619 | 4252.41 | 0.00 | 7380.19 | 5329.53 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 9272.058 | 9272.058 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 9272.06 | 9272.06 | 0.445913 | 18.83 | 11.49 | 0.00739930 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.8205 | 21.10 | 0.00779756 | 40.6811 | 2174.91 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 7538.744 | 6035.935 | 0.455416 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6982.53 | 6982.53 | 0.455416 | 25.42 | 14.22 | 0.00788515 | 12.80 | 9.63 | 0.00788515 | 28.13 | 0.00546644 | 13.13 | 5.6991 | 24.00 | 0.00803133 | 35.1195 | 4342.01 | 0.00 | 7537.46 | 5443.10 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 9448.611 | 9448.611 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 9448.61 | 9448.61 | 0.455416 | 18.88 | 11.41 | 0.00729773 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.6991 | 21.10 | 0.00768104 | 40.0816 | 2351.54 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 7487.069 | 5994.561 | 0.452294 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6934.66 | 6934.66 | 0.452294 | 25.42 | 14.22 | 0.00788449 | 12.80 | 9.63 | 0.00788449 | 28.13 | 0.00546644 | 13.13 | 5.7384 | 24.00 | 0.00803169 | 35.1211 | 4312.89 | 0.00 | 7485.79 | 5405.79 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 9390.658 | 9390.658 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | 9390.66 | 9390.66 | 0.452294 | 18.86 | 11.40 | 0.00729509 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 5.7384 | 21.10 | 0.00768104 | 40.0816 | 2351.54 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6767.820 | 5418.690 | 0.408844 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4924 | 1004.8586 | 0.9774 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.408844 | 0.39961949 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6268.81 | 6268.81 | 0.9263 | 0.39961949 | 0.408844 | 25.43 | 14.23 | 0.00788206 | 45640.1 | 12.80 | 9.62 | 0.00788206 | 32762.1 | -999.0 | -999.00 | -999.00 | -999.00 | 457.949 | 5810.86 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 6.3483 | 24.05 | 0.00804581 | 24.00 | 0.00804581 | 35.1822 | 3901.34 | 0.00 | 6766.67 | 4886.48 | 0.38383754 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8583.854 | 8583.854 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.408844 | 0.39961949 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | Sensible | 8583.85 | 8583.85 | 1.0000 | 0.39961949 | 0.408844 | 18.62 | 11.28 | 0.00725970 | 37121.3 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8583.85 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 6.3483 | 21.10 | 0.00768706 | 21.10 | 0.00768706 | 40.1120 | 2142.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6442.309 | 5158.069 | 0.389180 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4451 | 1004.8586 | 0.9774 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.389180 | 0.38039907 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5964.81 | 5964.81 | 0.9259 | 0.38039907 | 0.389180 | 25.44 | 14.21 | 0.00785666 | 45585.9 | 12.80 | 9.60 | 0.00785666 | 32697.9 | -999.0 | -999.00 | -999.00 | -999.00 | 435.924 | 5528.88 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 6.6690 | 24.05 | 0.00802746 | 24.00 | 0.00802746 | 35.1027 | 3717.64 | 0.00 | 6441.21 | 4651.45 | 0.36537618 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8218.765 | 8218.765 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.389180 | 0.38039907 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | Sensible | 8218.76 | 8218.76 | 1.0000 | 0.38039907 | 0.389180 | 18.50 | 11.29 | 0.00731527 | 37135.0 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8218.76 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 6.6690 | 21.10 | 0.00776973 | 21.10 | 0.00776973 | 40.5373 | 2008.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7405.446 | 5929.209 | 0.447363 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.2153 | 1004.8586 | 0.9774 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.447363 | 0.43726939 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | Sensible | 6938.84 | 6938.84 | 0.9370 | 0.43726939 | 0.447363 | 25.24 | 14.04 | 0.00773300 | 45064.0 | 12.80 | 9.48 | 0.00773300 | 32385.7 | -999.0 | -999.00 | -999.00 | -999.00 | 501.095 | 6437.75 | 25.76 | 0.00546288 | 12.29 | 0.03810604 | 8.5179 | 23.96 | 0.00794437 | 23.90 | 0.00795733 | 35.0090 | 3964.55 | 0.00 | 7404.19 | 5346.86 | 0.42000056 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9764.388 | 9764.388 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.447363 | 0.43726939 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:50:00 | Sensible | 9764.39 | 9764.39 | 1.0000 | 0.43726939 | 0.447363 | 17.78 | 10.88 | 0.00716428 | 36017.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9764.39 | -17.90 | 0.00095524 | -17.90 | 0.03810604 | 8.5179 | 21.10 | 0.00774240 | 21.10 | 0.00774240 | 40.3972 | 2598.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5697.194 | 4561.489 | 0.344168 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4084 | 1004.8586 | 0.9774 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.344168 | 0.33640227 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5273.98 | 5273.98 | 0.9257 | 0.33640227 | 0.344168 | 25.47 | 14.20 | 0.00783692 | 45562.2 | 12.80 | 9.58 | 0.00783692 | 32648.1 | -999.0 | -999.00 | -999.00 | -999.00 | 385.505 | 4888.47 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 7.5413 | 24.04 | 0.00803026 | 24.00 | 0.00803026 | 35.1148 | 3296.46 | 0.00 | 5696.22 | 4113.47 | 0.32311692 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7383.173 | 7383.173 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.344168 | 0.33640227 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | Sensible | 7383.17 | 7383.17 | 1.0000 | 0.33640227 | 0.344168 | 18.16 | 11.10 | 0.00725584 | 36637.9 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7383.17 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 7.5413 | 21.10 | 0.00776973 | 21.10 | 0.00776973 | 40.5373 | 2008.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5216.637 | 4176.728 | 0.315137 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4332 | 1004.8586 | 0.9774 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.315137 | 0.30802679 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4831.17 | 4831.17 | 0.9261 | 0.30802679 | 0.315137 | 25.49 | 14.22 | 0.00785021 | 45616.4 | 12.80 | 9.59 | 0.00785021 | 32681.7 | -999.0 | -999.00 | -999.00 | -999.00 | 352.988 | 4478.18 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 8.2360 | 24.03 | 0.00806416 | 24.00 | 0.00806416 | 35.2613 | 3024.29 | 0.00 | 5215.75 | 3766.50 | 0.29586206 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6844.215 | 6844.215 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.315137 | 0.30802679 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | Sensible | 6844.21 | 6844.21 | 1.0000 | 0.30802679 | 0.315137 | 17.89 | 11.04 | 0.00729395 | 36458.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6844.21 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 8.2360 | 21.10 | 0.00786286 | 21.10 | 0.00786286 | 41.0166 | 1244.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5201.133 | 4164.315 | 0.314200 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4324 | 1004.8586 | 0.9774 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.314200 | 0.30711136 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4816.80 | 4816.80 | 0.9261 | 0.30711136 | 0.314200 | 25.49 | 14.22 | 0.00784978 | 45616.0 | 12.80 | 9.59 | 0.00784978 | 32680.6 | -999.0 | -999.00 | -999.00 | -999.00 | 351.938 | 4464.86 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 8.2605 | 24.03 | 0.00806438 | 24.00 | 0.00806438 | 35.2623 | 3015.54 | 0.00 | 5200.25 | 3755.31 | 0.29498278 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6826.829 | 6826.829 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.314200 | 0.30711136 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | Sensible | 6826.83 | 6826.83 | 1.0000 | 0.30711136 | 0.314200 | 17.88 | 11.03 | 0.00729226 | 36444.7 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6826.83 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 8.2605 | 21.10 | 0.00786286 | 21.10 | 0.00786286 | 41.0166 | 1244.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5573.984 | 4462.840 | 0.336724 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5234 | 1004.8586 | 0.9774 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.336724 | 0.32912707 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5166.44 | 5166.44 | 0.9269 | 0.32912707 | 0.336724 | 25.47 | 14.25 | 0.00789874 | 45725.0 | 12.80 | 9.64 | 0.00789874 | 32804.2 | -999.0 | -999.00 | -999.00 | -999.00 | 377.168 | 4789.28 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 7.7080 | 24.03 | 0.00810188 | 24.00 | 0.00810188 | 35.4247 | 3226.74 | 0.00 | 5573.04 | 4024.51 | 0.31612904 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7245.000 | 7245.000 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.336724 | 0.32912707 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | Sensible | 7245.00 | 7245.00 | 1.0000 | 0.32912707 | 0.336724 | 18.09 | 11.01 | 0.00717935 | 36377.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7245.00 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 7.7080 | 21.10 | 0.00769916 | 21.10 | 0.00769916 | 40.1738 | 1380.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5610.038 | 4491.707 | 0.338902 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5248 | 1004.8586 | 0.9774 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.338902 | 0.33125596 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5199.87 | 5199.87 | 0.9269 | 0.33125596 | 0.338902 | 25.47 | 14.25 | 0.00789952 | 45725.2 | 12.80 | 9.64 | 0.00789952 | 32806.1 | -999.0 | -999.00 | -999.00 | -999.00 | 379.607 | 4820.26 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 7.6584 | 24.03 | 0.00810131 | 24.00 | 0.00810131 | 35.4222 | 3247.12 | 0.00 | 5609.08 | 4050.54 | 0.31817385 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7285.432 | 7285.432 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.338902 | 0.33125596 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:50:00 | Sensible | 7285.43 | 7285.43 | 1.0000 | 0.33125596 | 0.338902 | 18.11 | 11.02 | 0.00718432 | 36410.1 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7285.43 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 7.6584 | 21.10 | 0.00770093 | 21.10 | 0.00770093 | 40.1829 | 1388.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 17197.554 | 13769.312 | 1.038904 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5005 | 1004.8586 | 0.9774 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 1.038904 | 1.01546409 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 15925.54 | 15925.54 | 0.9260 | 1.01546409 | 1.038904 | 25.39 | 14.22 | 0.00788642 | 45608.8 | 12.80 | 9.63 | 0.00788642 | 32773.1 | -999.0 | -999.00 | -999.00 | -999.00 | 1163.685 | 14761.86 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 4.9965 | 24.06 | 0.00801369 | 24.00 | 0.00801369 | 35.0432 | 19754.46 | 0.00 | 17194.63 | 12416.92 | 0.97536094 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21274.963 | 21274.963 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 1.038904 | 1.01546409 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 21274.96 | 21274.96 | 1.0000 | 1.01546409 | 1.038904 | 19.15 | 11.42 | 0.00719558 | 37494.9 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21274.96 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 4.9965 | 21.10 | 0.00752378 | 21.10 | 0.00752378 | 39.2712 | 7715.06 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 16701.697 | 13372.301 | 1.008950 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4765 | 1004.8586 | 0.9774 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 1.008950 | 0.98618519 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 15463.10 | 15463.10 | 0.9258 | 0.98618519 | 1.008950 | 25.40 | 14.21 | 0.00787352 | 45581.5 | 12.80 | 9.62 | 0.00787352 | 32740.5 | -999.0 | -999.00 | -999.00 | -999.00 | 1130.132 | 14332.97 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 5.1449 | 24.06 | 0.00800407 | 24.00 | 0.00800407 | 35.0015 | 19195.10 | 0.00 | 16698.85 | 12058.90 | 0.94723833 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20718.542 | 20718.542 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 1.008950 | 0.98618519 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 20718.54 | 20718.54 | 1.0000 | 0.98618519 | 1.008950 | 19.09 | 11.50 | 0.00730846 | 37722.6 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20718.54 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 5.1449 | 21.10 | 0.00765305 | 21.10 | 0.00765305 | 39.9369 | 7073.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 15073.384 | 12068.584 | 0.910583 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4754 | 1004.8586 | 0.9774 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.910583 | 0.89003822 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 13957.28 | 13957.28 | 0.9260 | 0.89003822 | 0.910583 | 25.41 | 14.21 | 0.00787297 | 45597.1 | 12.80 | 9.62 | 0.00787297 | 32739.1 | -999.0 | -999.00 | -999.00 | -999.00 | 1019.951 | 12937.33 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 5.7006 | 24.06 | 0.00801845 | 24.00 | 0.00801845 | 35.0638 | 17347.84 | 0.00 | 15070.82 | 10883.23 | 0.85488843 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18892.760 | 18892.760 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.910583 | 0.89003822 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 18892.76 | 18892.76 | 1.0000 | 0.89003822 | 0.910583 | 18.88 | 11.28 | 0.00714933 | 37098.0 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18892.76 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 5.7006 | 21.10 | 0.00752378 | 21.10 | 0.00752378 | 39.2712 | 7715.06 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14593.038 | 11683.992 | 0.881565 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4411 | 1004.8586 | 0.9774 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.881565 | 0.86167518 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 13508.17 | 13508.17 | 0.9257 | 0.86167518 | 0.881565 | 25.42 | 14.20 | 0.00785449 | 45555.7 | 12.80 | 9.60 | 0.00785449 | 32692.4 | -999.0 | -999.00 | -999.00 | -999.00 | 987.448 | 12520.72 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 5.8883 | 24.05 | 0.00800390 | 24.00 | 0.00800390 | 35.0007 | 16802.68 | 0.00 | 14590.55 | 10536.42 | 0.82764553 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18353.778 | 18353.778 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.881565 | 0.86167518 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 18353.78 | 18353.78 | 1.0000 | 0.86167518 | 0.881565 | 18.80 | 11.35 | 0.00725867 | 37301.1 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18353.78 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 5.8883 | 21.10 | 0.00765305 | 21.10 | 0.00765305 | 39.9369 | 7073.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13097.838 | 10486.853 | 0.791240 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4625 | 1004.8586 | 0.9774 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.791240 | 0.77338810 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12128.95 | 12128.95 | 0.9260 | 0.77338810 | 0.791240 | 25.44 | 14.22 | 0.00786602 | 45606.3 | 12.80 | 9.61 | 0.00786602 | 32721.6 | -999.0 | -999.00 | -999.00 | -999.00 | 886.275 | 11242.67 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 6.5605 | 24.05 | 0.00803450 | 24.00 | 0.00803450 | 35.1331 | 15111.10 | 0.00 | 13095.61 | 9456.86 | 0.74284512 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16676.681 | 16676.681 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.791240 | 0.77338810 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 16676.68 | 16676.68 | 1.0000 | 0.77338810 | 0.791240 | 18.54 | 11.28 | 0.00728890 | 37111.2 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16676.68 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 6.5605 | 21.10 | 0.00773359 | 21.10 | 0.00773359 | 40.3510 | 3769.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13056.241 | 10453.548 | 0.788728 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4617 | 1004.8586 | 0.9774 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.788728 | 0.77093195 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12090.39 | 12090.39 | 0.9260 | 0.77093195 | 0.788728 | 25.44 | 14.22 | 0.00786559 | 45605.9 | 12.80 | 9.61 | 0.00786559 | 32720.5 | -999.0 | -999.00 | -999.00 | -999.00 | 883.460 | 11206.93 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 6.5814 | 24.05 | 0.00803461 | 24.00 | 0.00803461 | 35.1336 | 15064.16 | 0.00 | 13054.02 | 9426.82 | 0.74048597 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16630.034 | 16630.034 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.788728 | 0.77093195 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 16630.03 | 16630.03 | 1.0000 | 0.77093195 | 0.788728 | 18.53 | 11.27 | 0.00728748 | 37099.3 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16630.03 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 6.5814 | 21.10 | 0.00773359 | 21.10 | 0.00773359 | 40.3510 | 3769.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13686.847 | 10958.446 | 0.826822 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5107 | 1004.8586 | 0.9774 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.826822 | 0.80816732 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12679.97 | 12679.97 | 0.9264 | 0.80816732 | 0.826822 | 25.43 | 14.23 | 0.00789194 | 45663.3 | 12.80 | 9.63 | 0.00789194 | 32787.0 | -999.0 | -999.00 | -999.00 | -999.00 | 926.130 | 11753.84 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 6.2781 | 24.05 | 0.00805442 | 24.00 | 0.00805442 | 35.2194 | 15776.85 | 0.00 | 13684.52 | 9882.13 | 0.77625082 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17337.499 | 17337.499 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.826822 | 0.80816732 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 17337.50 | 17337.50 | 1.0000 | 0.80816732 | 0.826822 | 18.65 | 11.13 | 0.00708490 | 36705.7 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17337.50 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 6.2781 | 21.10 | 0.00749551 | 21.10 | 0.00749551 | 39.1244 | 4399.13 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13643.863 | 10924.030 | 0.824226 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5104 | 1004.8586 | 0.9774 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.824226 | 0.80562923 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12640.16 | 12640.16 | 0.9264 | 0.80562923 | 0.824226 | 25.43 | 14.23 | 0.00789175 | 45663.5 | 12.80 | 9.63 | 0.00789175 | 32786.5 | -999.0 | -999.00 | -999.00 | -999.00 | 923.222 | 11716.94 | 28.13 | 0.00546644 | 13.13 | 0.05190911 | 6.2979 | 24.05 | 0.00805477 | 24.00 | 0.00805477 | 35.2209 | 15728.25 | 0.00 | 13641.54 | 9851.10 | 0.77381297 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17289.294 | 17289.294 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.824226 | 0.80562923 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 17289.29 | 17289.29 | 1.0000 | 0.80562923 | 0.824226 | 18.64 | 11.13 | 0.00708361 | 36694.6 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17289.29 | -17.90 | 0.00095524 | -17.90 | 0.05190911 | 6.2979 | 21.10 | 0.00749551 | 21.10 | 0.00749551 | 39.1244 | 4399.13 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9555.636 | 7650.770 | 0.577256 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4919 | 1004.8586 | 0.9774 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.577256 | 0.56423168 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 8846.91 | 8846.91 | 0.9258 | 0.56423168 | 0.577256 | 25.37 | 14.21 | 0.00788180 | 45580.9 | 12.80 | 9.62 | 0.00788180 | 32761.4 | -999.0 | -999.00 | -999.00 | -999.00 | 646.589 | 8200.32 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 4.4962 | 24.07 | 0.00799551 | 24.00 | 0.00799551 | 34.9645 | 5480.98 | 0.00 | 9554.01 | 6899.33 | 0.54194879 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11710.775 | 11710.775 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.577256 | 0.56423168 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 11710.77 | 11710.77 | 1.0000 | 0.56423168 | 0.577256 | 19.35 | 11.61 | 0.00732905 | 38031.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11710.77 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 4.4962 | 21.10 | 0.00762912 | 21.10 | 0.00762912 | 39.8153 | 3325.52 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9477.542 | 7588.244 | 0.572538 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4760 | 1004.8586 | 0.9774 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.572538 | 0.55962051 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 8773.21 | 8773.21 | 0.9257 | 0.55962051 | 0.572538 | 25.38 | 14.20 | 0.00787328 | 45560.4 | 12.80 | 9.62 | 0.00787328 | 32739.9 | -999.0 | -999.00 | -999.00 | -999.00 | 641.305 | 8131.91 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 4.5332 | 24.07 | 0.00798756 | 24.00 | 0.00798756 | 34.9301 | 5436.63 | 0.00 | 9475.93 | 6842.94 | 0.53751973 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11623.003 | 11623.003 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.572538 | 0.55962051 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 11623.00 | 11623.00 | 1.0000 | 0.55962051 | 0.572538 | 19.33 | 11.67 | 0.00740028 | 38198.1 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11623.00 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 4.5332 | 21.10 | 0.00770632 | 21.10 | 0.00770632 | 40.2123 | 3149.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7997.400 | 6403.160 | 0.483123 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4521 | 1004.8586 | 0.9774 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.483123 | 0.47222252 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7403.00 | 7403.00 | 0.9257 | 0.47222252 | 0.483123 | 25.41 | 14.20 | 0.00786040 | 45558.5 | 12.80 | 9.60 | 0.00786040 | 32707.4 | -999.0 | -999.00 | -999.00 | -999.00 | 541.150 | 6861.85 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 5.3722 | 24.06 | 0.00799632 | 24.00 | 0.00799632 | 34.9680 | 4600.75 | 0.00 | 7996.04 | 5774.26 | 0.45357330 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9963.218 | 9963.218 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.483123 | 0.47222252 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 9963.22 | 9963.22 | 1.0000 | 0.47222252 | 0.483123 | 19.00 | 11.43 | 0.00727059 | 37535.6 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9963.22 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 5.3722 | 21.10 | 0.00762912 | 21.10 | 0.00762912 | 39.8153 | 3325.52 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7916.257 | 6338.193 | 0.478221 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4292 | 1004.8586 | 0.9774 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.478221 | 0.46743126 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7326.22 | 7326.22 | 0.9255 | 0.46743126 | 0.478221 | 25.41 | 14.19 | 0.00784810 | 45529.2 | 12.80 | 9.59 | 0.00784810 | 32676.3 | -999.0 | -999.00 | -999.00 | -999.00 | 535.659 | 6790.56 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 5.4273 | 24.06 | 0.00798478 | 24.00 | 0.00798478 | 34.9180 | 4554.87 | 0.00 | 7914.91 | 5715.67 | 0.44897126 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9872.059 | 9872.059 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.478221 | 0.46743126 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 9872.06 | 9872.06 | 1.0000 | 0.46743126 | 0.478221 | 18.98 | 11.49 | 0.00733992 | 37689.9 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9872.06 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 5.4273 | 21.10 | 0.00770632 | 21.10 | 0.00770632 | 40.2123 | 3149.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7433.281 | 5951.496 | 0.449045 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4707 | 1004.8586 | 0.9774 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.449045 | 0.43891300 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6882.97 | 6882.97 | 0.9260 | 0.43891300 | 0.449045 | 25.42 | 14.21 | 0.00787043 | 45598.5 | 12.80 | 9.61 | 0.00787043 | 32732.7 | -999.0 | -999.00 | -999.00 | -999.00 | 502.978 | 6379.99 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 5.7800 | 24.06 | 0.00801791 | 24.00 | 0.00801791 | 35.0614 | 4281.86 | 0.00 | 7432.02 | 5366.95 | 0.42157925 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9330.182 | 9330.182 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.449045 | 0.43891300 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 9330.18 | 9330.18 | 1.0000 | 0.43891300 | 0.449045 | 18.85 | 11.49 | 0.00740208 | 37708.0 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9330.18 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 5.7800 | 21.10 | 0.00779756 | 21.10 | 0.00779756 | 40.6811 | 2174.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7381.451 | 5909.997 | 0.445913 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4690 | 1004.8586 | 0.9774 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.445913 | 0.43585257 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6834.92 | 6834.92 | 0.9260 | 0.43585257 | 0.445913 | 25.42 | 14.21 | 0.00786951 | 45597.4 | 12.80 | 9.61 | 0.00786951 | 32730.4 | -999.0 | -999.00 | -999.00 | -999.00 | 499.471 | 6335.45 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 5.8205 | 24.06 | 0.00801803 | 24.00 | 0.00801803 | 35.0619 | 4252.41 | 0.00 | 7380.19 | 5329.53 | 0.41863969 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9272.058 | 9272.058 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.445913 | 0.43585257 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 9272.06 | 9272.06 | 1.0000 | 0.43585257 | 0.445913 | 18.83 | 11.49 | 0.00739930 | 37684.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9272.06 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 5.8205 | 21.10 | 0.00779756 | 21.10 | 0.00779756 | 40.6811 | 2174.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7538.744 | 6035.935 | 0.455416 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4981 | 1004.8586 | 0.9774 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.455416 | 0.44514028 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6982.53 | 6982.53 | 0.9262 | 0.44514028 | 0.455416 | 25.42 | 14.22 | 0.00788515 | 45633.7 | 12.80 | 9.63 | 0.00788515 | 32769.9 | -999.0 | -999.00 | -999.00 | -999.00 | 510.115 | 6472.42 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 5.6991 | 24.06 | 0.00803133 | 24.00 | 0.00803133 | 35.1195 | 4342.01 | 0.00 | 7537.46 | 5443.10 | 0.42756061 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9448.611 | 9448.611 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.455416 | 0.44514028 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 9448.61 | 9448.61 | 1.0000 | 0.44514028 | 0.455416 | 18.88 | 11.41 | 0.00729773 | 37475.1 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9448.61 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 5.6991 | 21.10 | 0.00768104 | 21.10 | 0.00768104 | 40.0816 | 2351.54 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7487.069 | 5994.561 | 0.452294 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.4969 | 1004.8586 | 0.9774 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.452294 | 0.44208898 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6934.66 | 6934.66 | 0.9262 | 0.44208898 | 0.452294 | 25.42 | 14.22 | 0.00788449 | 45633.5 | 12.80 | 9.63 | 0.00788449 | 32768.2 | -999.0 | -999.00 | -999.00 | -999.00 | 506.618 | 6428.04 | 28.13 | 0.00546644 | 13.13 | 0.02595455 | 5.7384 | 24.06 | 0.00803169 | 24.00 | 0.00803169 | 35.1211 | 4312.89 | 0.00 | 7485.79 | 5405.79 | 0.42462981 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 13.42 | 0.00926411 | 37693.4 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9390.658 | 9390.658 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.452294 | 0.44208898 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:00:00 | Sensible | 9390.66 | 9390.66 | 1.0000 | 0.44208898 | 0.452294 | 18.86 | 11.40 | 0.00729509 | 37452.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9390.66 | -17.90 | 0.00095524 | -17.90 | 0.02595455 | 5.7384 | 21.10 | 0.00768104 | 21.10 | 0.00768104 | 40.0816 | 2351.54 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 2037.83 | 4336.67 | 1472.67 |
| G NW APARTMENT | 4295.00 | 6464.83 | 3703.67 |
| OFFICE | 960.33 | 951.33 | 370.83 |
| G NE APARTMENT | 4416.83 | 6395.67 | 3734.33 |
| G N1 APARTMENT | 3820.67 | 6541.50 | 3324.17 |
| G N2 APARTMENT | 3830.67 | 6539.67 | 3328.17 |
| G S1 APARTMENT | 1563.17 | 4232.50 | 1025.83 |
| G S2 APARTMENT | 1733.50 | 4123.33 | 1091.00 |
| M SW APARTMENT | 1478.33 | 3975.33 | 809.33 |
| M NW APARTMENT | 2939.67 | 6013.83 | 2137.83 |
| M SE APARTMENT | 1497.83 | 3952.17 | 824.83 |
| M NE APARTMENT | 3031.33 | 5941.17 | 2167.17 |
| M N1 APARTMENT | 2206.67 | 6108.33 | 1586.67 |
| M N2 APARTMENT | 2212.83 | 6105.00 | 1590.50 |
| M S1 APARTMENT | 967.33 | 3875.67 | 404.17 |
| M S2 APARTMENT | 967.00 | 3872.33 | 404.50 |
| T SW APARTMENT | 2898.00 | 4518.50 | 2172.00 |
| T NW APARTMENT | 4775.50 | 6493.83 | 3656.00 |
| T SE APARTMENT | 2869.50 | 4504.83 | 2193.33 |
| T NE APARTMENT | 4788.33 | 6416.67 | 3603.83 |
| T N1 APARTMENT | 4202.17 | 6497.00 | 3410.17 |
| T N2 APARTMENT | 4212.67 | 6493.00 | 3413.00 |
| T S1 APARTMENT | 2324.83 | 4426.83 | 1740.67 |
| T S2 APARTMENT | 2329.17 | 4426.83 | 1748.50 |
| T CORRIDOR | 7411.17 | 8600.83 | 7318.17 |
| G CORRIDOR | 6055.50 | 6424.17 | 4011.83 |
| M CORRIDOR | 8320.83 | 8732.33 | 8309.67 |
| Facility | 8760.00 | 8760.00 | 8755.50 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.097 | 0.000 | 0.046 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.098 | 0.000 | 0.055 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.515 | 0.100 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.098 | 0.000 | 0.055 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.059 | 0.000 | 0.055 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.059 | 0.000 | 0.055 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.059 | 0.000 | 0.046 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.059 | 0.000 | 0.046 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.140 | 0.000 | 0.056 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.141 | 0.000 | 0.068 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.140 | 0.000 | 0.056 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.141 | 0.000 | 0.068 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.085 | 0.000 | 0.068 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.085 | 0.000 | 0.068 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.084 | 0.000 | 0.056 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.084 | 0.000 | 0.056 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.351 | 0.184 | 0.000 | 0.067 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.187 | 0.000 | 0.081 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.351 | 0.184 | 0.000 | 0.067 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.187 | 0.000 | 0.081 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.113 | 0.000 | 0.081 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.113 | 0.000 | 0.081 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.111 | 0.000 | 0.067 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.111 | 0.000 | 0.067 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.502 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.19 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 132918.52 | 951421.30 | 229380.66 | 1180801.96 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 2615.00 |
| G NW APARTMENT | 818502.78 | 128489.91 | 946992.69 | 229380.66 | 1176373.34 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 229380.66 | 1431092.63 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 128944.08 | 947446.86 | 229380.66 | 1176827.51 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 0.00 |
| G N1 APARTMENT | 818502.78 | 128576.66 | 947079.44 | 138356.59 | 1085436.03 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 0.00 |
| G N2 APARTMENT | 818502.78 | 128618.86 | 947121.63 | 138356.59 | 1085478.22 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 0.00 |
| G S1 APARTMENT | 818502.78 | 133340.67 | 951843.45 | 138356.59 | 1090200.04 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 133409.53 | 951912.31 | 138356.59 | 1090268.90 | 818502.78 | 0.00 | 7385.33 | 1374.67 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 160705.12 | 1797710.68 | 329637.96 | 2127348.64 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 158172.39 | 1795177.94 | 329637.96 | 2124815.90 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 0.00 |
| M SE APARTMENT | 1637005.55 | 160783.57 | 1797789.12 | 329637.96 | 2127427.08 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 158467.78 | 1795473.34 | 329637.96 | 2125111.30 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 158025.05 | 1795030.60 | 198829.25 | 1993859.85 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 158051.71 | 1795057.27 | 198829.25 | 1993886.52 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 160738.11 | 1797743.67 | 198829.25 | 1996572.92 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 160741.55 | 1797747.11 | 198829.25 | 1996576.36 | 1637005.55 | 0.00 | 7384.50 | 1375.50 | 2615.00 |
| T SW APARTMENT | 818502.78 | 190785.87 | 1009288.65 | 436044.05 | 1445332.70 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 2615.00 |
| T NW APARTMENT | 818502.78 | 188464.95 | 1006967.73 | 436044.05 | 1443011.78 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 0.00 |
| T SE APARTMENT | 818502.78 | 191335.83 | 1009838.61 | 436044.05 | 1445882.66 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 2615.00 |
| T NE APARTMENT | 818502.78 | 189534.52 | 1008037.30 | 436044.05 | 1444081.35 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 0.00 |
| T N1 APARTMENT | 818502.78 | 188541.94 | 1007044.72 | 263010.70 | 1270055.42 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 0.00 |
| T N2 APARTMENT | 818502.78 | 188642.40 | 1007145.18 | 263010.70 | 1270155.88 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 0.00 |
| T S1 APARTMENT | 818502.78 | 191160.68 | 1009663.45 | 263010.70 | 1272674.16 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 191187.84 | 1009690.61 | 263010.70 | 1272701.32 | 818502.78 | 0.00 | 7384.17 | 1375.83 | 2615.00 |
| Total Facility | 39671342.50 | 4985322.84 | 44656665.34 | 8494905.68 | 53151571.02 | 39671342.50 | 0.00 | 8760.00 | 1376.33 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0072 | 0.0365 | 0.0260 | 0.00 | 5397.33 | 747.67 |
| G NW APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0073 | 0.0373 | 0.0260 | 0.00 | 7385.33 | 1374.67 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0074 | 0.0455 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0073 | 0.0373 | 0.0260 | 0.00 | 7385.33 | 1374.67 |
| G N1 APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0044 | 0.0344 | 0.0260 | 0.00 | 7385.33 | 1374.67 |
| G N2 APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0044 | 0.0344 | 0.0260 | 0.00 | 7385.33 | 1374.67 |
| G S1 APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0043 | 0.0337 | 0.0260 | 0.00 | 5397.33 | 747.67 |
| G S2 APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0043 | 0.0337 | 0.0260 | 0.00 | 5397.33 | 747.67 |
| M SW APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0103 | 0.0663 | 0.0519 | 0.00 | 5396.83 | 748.17 |
| M NW APARTMENT | 0.0519 | 0.0050 | 0.0569 | 0.0105 | 0.0674 | 0.0519 | 0.00 | 7384.50 | 1375.50 |
| M SE APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0103 | 0.0663 | 0.0519 | 0.00 | 5396.83 | 748.17 |
| M NE APARTMENT | 0.0519 | 0.0050 | 0.0569 | 0.0105 | 0.0674 | 0.0519 | 0.00 | 7384.50 | 1375.50 |
| M N1 APARTMENT | 0.0519 | 0.0050 | 0.0569 | 0.0063 | 0.0632 | 0.0519 | 0.00 | 7384.50 | 1375.50 |
| M N2 APARTMENT | 0.0519 | 0.0050 | 0.0569 | 0.0063 | 0.0632 | 0.0519 | 0.00 | 7384.50 | 1375.50 |
| M S1 APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0062 | 0.0623 | 0.0519 | 0.00 | 5396.83 | 748.17 |
| M S2 APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0062 | 0.0623 | 0.0519 | 0.00 | 5396.83 | 748.17 |
| T SW APARTMENT | 0.0260 | 0.0049 | 0.0309 | 0.0136 | 0.0445 | 0.0260 | 0.00 | 5396.83 | 748.17 |
| T NW APARTMENT | 0.0260 | 0.0060 | 0.0319 | 0.0138 | 0.0458 | 0.0260 | 0.00 | 7384.17 | 1375.83 |
| T SE APARTMENT | 0.0260 | 0.0049 | 0.0309 | 0.0136 | 0.0445 | 0.0260 | 0.00 | 5396.83 | 748.17 |
| T NE APARTMENT | 0.0260 | 0.0060 | 0.0320 | 0.0138 | 0.0458 | 0.0260 | 0.00 | 7384.17 | 1375.83 |
| T N1 APARTMENT | 0.0260 | 0.0060 | 0.0319 | 0.0083 | 0.0403 | 0.0260 | 0.00 | 7384.17 | 1375.83 |
| T N2 APARTMENT | 0.0260 | 0.0060 | 0.0319 | 0.0083 | 0.0403 | 0.0260 | 0.00 | 7384.17 | 1375.83 |
| T S1 APARTMENT | 0.0260 | 0.0049 | 0.0309 | 0.0082 | 0.0391 | 0.0260 | 0.00 | 5396.83 | 748.17 |
| T S2 APARTMENT | 0.0260 | 0.0049 | 0.0309 | 0.0082 | 0.0391 | 0.0260 | 0.00 | 5396.83 | 748.17 |
| Total Facility | 1.2580 | 0.1434 | 1.4014 | 0.2676 | 1.6690 | 1.2580 | 0.00 | 8760.00 | 1376.33 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 132918.52 | 132918.52 | 818502.78 | 8001.25 | 34.28 | 724.47 | 627.00 |
| SPLIT GNW | 0.00 | 128489.91 | 128489.91 | 818502.78 | 8069.43 | 32.98 | 657.58 | 0.00 |
| SPLIT OFFICE | 1148096.73 | 0.00 | 1148096.73 | 1201711.97 | 8760.00 | 0.00 | 0.00 | 7010.00 |
| SPLIT GNE | 0.00 | 128944.08 | 128944.08 | 818502.78 | 8060.06 | 33.50 | 666.44 | 0.00 |
| SPLIT GN1 | 0.00 | 128576.66 | 128576.66 | 818502.78 | 8067.22 | 34.58 | 658.19 | 0.00 |
| SPLIT GN2 | 0.00 | 128618.86 | 128618.86 | 818502.78 | 8066.89 | 33.94 | 659.17 | 0.00 |
| SPLIT GS1 | 0.00 | 133340.67 | 133340.67 | 818502.78 | 7992.58 | 33.25 | 734.17 | 627.00 |
| SPLIT GS2 | 0.00 | 133409.53 | 133409.53 | 818502.78 | 7990.58 | 34.75 | 734.67 | 627.00 |
| SPLIT MSW | 0.00 | 160705.12 | 160705.12 | 1637005.55 | 8677.17 | 9.00 | 73.83 | 627.33 |
| SPLIT MNW | 0.00 | 158172.39 | 158172.39 | 1637005.55 | 8685.08 | 7.75 | 67.17 | 0.00 |
| SPLIT MSE | 0.00 | 160783.57 | 160783.57 | 1637005.55 | 8676.83 | 9.17 | 74.00 | 627.33 |
| SPLIT MNE | 0.00 | 158467.78 | 158467.78 | 1637005.55 | 8685.42 | 6.58 | 68.00 | 0.00 |
| SPLIT MN1 | 0.00 | 158025.05 | 158025.05 | 1637005.55 | 8685.67 | 7.17 | 67.17 | 0.00 |
| SPLIT MN2 | 0.00 | 158051.71 | 158051.71 | 1637005.55 | 8685.50 | 7.33 | 67.17 | 0.00 |
| SPLIT MS1 | 0.00 | 160738.11 | 160738.11 | 1637005.55 | 8676.67 | 9.50 | 73.83 | 627.33 |
| SPLIT MS2 | 0.00 | 160741.55 | 160741.55 | 1637005.55 | 8676.67 | 9.50 | 73.83 | 627.33 |
| SPLIT TSW | 0.00 | 190785.87 | 190785.87 | 818502.78 | 7602.17 | 22.83 | 1135.00 | 627.67 |
| SPLIT TNW | 0.00 | 188464.95 | 188464.95 | 818502.78 | 7605.25 | 23.88 | 1130.87 | 0.00 |
| SPLIT TSE | 0.00 | 191335.83 | 191335.83 | 818502.78 | 7601.83 | 22.50 | 1135.67 | 627.67 |
| SPLIT TNE | 0.00 | 189534.52 | 189534.52 | 818502.78 | 7597.08 | 22.25 | 1140.67 | 0.00 |
| SPLIT TN1 | 0.00 | 188541.94 | 188541.94 | 818502.78 | 7608.00 | 21.25 | 1130.75 | 0.00 |
| SPLIT TN2 | 0.00 | 188642.40 | 188642.40 | 818502.78 | 7607.00 | 21.25 | 1131.75 | 0.00 |
| SPLIT TS1 | 0.00 | 191160.68 | 191160.68 | 818502.78 | 7601.83 | 22.50 | 1135.67 | 627.67 |
| SPLIT TS2 | 0.00 | 191187.84 | 191187.84 | 818502.78 | 7601.83 | 22.50 | 1135.67 | 627.67 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 5684.00 | 17.83 | 443.17 |
| SPLIT GNW | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 8069.43 | 32.98 | 657.58 |
| SPLIT OFFICE | 0.0364 | 0.0000 | 0.0364 | 0.0381 | 1750.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 8060.06 | 33.50 | 666.44 |
| SPLIT GN1 | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 8067.22 | 34.58 | 658.19 |
| SPLIT GN2 | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 8066.89 | 33.94 | 659.17 |
| SPLIT GS1 | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 5680.17 | 17.50 | 447.33 |
| SPLIT GS2 | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 5679.25 | 17.75 | 448.00 |
| SPLIT MSW | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 6088.33 | 5.83 | 50.83 |
| SPLIT MNW | 0.0000 | 0.0050 | 0.0050 | 0.0519 | 8685.08 | 7.75 | 67.17 |
| SPLIT MSE | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 6088.33 | 5.83 | 50.83 |
| SPLIT MNE | 0.0000 | 0.0050 | 0.0050 | 0.0519 | 8685.42 | 6.58 | 68.00 |
| SPLIT MN1 | 0.0000 | 0.0050 | 0.0050 | 0.0519 | 8685.67 | 7.17 | 67.17 |
| SPLIT MN2 | 0.0000 | 0.0050 | 0.0050 | 0.0519 | 8685.50 | 7.33 | 67.17 |
| SPLIT MS1 | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 6088.33 | 5.83 | 50.83 |
| SPLIT MS2 | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 6088.33 | 5.83 | 50.83 |
| SPLIT TSW | 0.0000 | 0.0049 | 0.0049 | 0.0260 | 5494.50 | 9.33 | 641.17 |
| SPLIT TNW | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 7605.25 | 23.88 | 1130.87 |
| SPLIT TSE | 0.0000 | 0.0049 | 0.0049 | 0.0260 | 5494.50 | 9.00 | 641.50 |
| SPLIT TNE | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 7597.08 | 22.25 | 1140.67 |
| SPLIT TN1 | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 7608.00 | 21.25 | 1130.75 |
| SPLIT TN2 | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 7607.00 | 21.25 | 1131.75 |
| SPLIT TS1 | 0.0000 | 0.0049 | 0.0049 | 0.0260 | 5494.50 | 8.83 | 641.67 |
| SPLIT TS2 | 0.0000 | 0.0049 | 0.0049 | 0.0260 | 5494.50 | 8.83 | 641.67 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0364 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 102.13 | 1741.52 | 19-APR-22:10 | 9497.87 | 26-JUN-17:20 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| ElectricityPurchased:Plant | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| Cogeneration:ElectricityPurchased | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| General:Cogeneration:ElectricityPurchased | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| ElectricityNet:Plant | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| Cogeneration:ElectricityNet | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| General:Cogeneration:ElectricityNet | 1290.60 | 16951.99 | 15-MAY-04:50 | 91996.99 | 16-AUG-16:40 |
| Electricity:HVAC | 210.41 | 1741.52 | 19-APR-22:10 | 36513.81 | 26-JUN-15:10 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 102.13 | 1741.52 | 19-APR-22:10 | 9497.87 | 26-JUN-17:20 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 108.27 | 0.00 | 01-JAN-00:10 | 27189.61 | 26-JUN-15:10 |
| General:Cooling:Electricity | 108.27 | 0.00 | 01-JAN-00:10 | 27189.61 | 26-JUN-15:10 |
| ExteriorLights:Electricity | 50.00 | 0.00 | 01-JAN-07:30 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 50.00 | 0.00 | 01-JAN-07:30 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 472.31 | 1950.00 | 01-JAN-00:10 | 37932.64 | 27-JAN-07:10 |
| WaterSystems:Electricity | 472.31 | 1950.00 | 01-JAN-00:10 | 37932.64 | 27-JAN-07:10 |
| Water Heater:WaterSystems:Electricity | 472.31 | 1950.00 | 01-JAN-00:10 | 37932.64 | 27-JAN-07:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 347.32 | 0.00 | 19-JAN-14:50 | 111916.11 | 22-DEC-04:00 |
| NaturalGas:HVAC | 347.32 | 0.00 | 19-JAN-14:50 | 111916.11 | 22-DEC-04:00 |
| Heating:NaturalGas | 347.32 | 0.00 | 19-JAN-14:50 | 111916.11 | 22-DEC-04:00 |
| General:Heating:NaturalGas | 347.32 | 0.00 | 19-JAN-14:50 | 111916.11 | 22-DEC-04:00 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 1313.77 | 2253.63 | 04-MAY-08:40 | 154730.61 | 26-JUN-17:00 |
| EnergyTransfer:Building | 631.51 | 2143.87 | 04-MAY-08:40 | 67699.99 | 26-JUN-17:20 |
| EnergyTransfer:Zone:G SW APARTMENT | 17.87 | 0.02 | 04-APR-12:00 | 2334.03 | 16-AUG-16:30 |
| Heating:EnergyTransfer | 133.27 | 0.00 | 19-JAN-14:20 | 59865.75 | 22-DEC-04:00 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 3.45 | 0.00 | 01-JAN-00:10 | 1911.35 | 21-DEC-08:10 |
| General:Heating:EnergyTransfer | 133.27 | 0.00 | 19-JAN-14:20 | 59865.75 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 3.45 | 0.00 | 01-JAN-00:10 | 1911.35 | 21-DEC-08:10 |
| Cooling:EnergyTransfer | 498.24 | 0.00 | 05-JAN-07:30 | 67455.10 | 16-AUG-15:20 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 14.42 | 0.00 | 01-JAN-02:10 | 2334.03 | 16-AUG-16:30 |
| General:Cooling:EnergyTransfer | 498.24 | 0.00 | 05-JAN-07:30 | 67455.10 | 16-AUG-15:20 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 14.42 | 0.00 | 01-JAN-02:10 | 2334.03 | 16-AUG-16:30 |
| EnergyTransfer:Zone:G NW APARTMENT | 16.53 | 0.02 | 01-DEC-12:30 | 2137.81 | 23-DEC-08:00 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 7.34 | 0.00 | 09-JAN-15:20 | 2137.81 | 23-DEC-08:00 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 7.34 | 0.00 | 09-JAN-15:20 | 2137.81 | 23-DEC-08:00 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 9.18 | 0.00 | 01-JAN-00:10 | 2063.23 | 26-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 9.18 | 0.00 | 01-JAN-00:10 | 2063.23 | 26-JUN-17:30 |
| EnergyTransfer:Zone:OFFICE | 14.90 | 0.01 | 28-DEC-15:40 | 3911.09 | 06-FEB-09:10 |
| Heating:EnergyTransfer:Zone:OFFICE | 3.11 | 0.00 | 01-JAN-00:10 | 3911.09 | 06-FEB-09:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 3.11 | 0.00 | 01-JAN-00:10 | 3911.09 | 06-FEB-09:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 11.79 | 0.00 | 03-JAN-08:30 | 3887.60 | 17-JUL-08:10 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 11.79 | 0.00 | 03-JAN-08:30 | 3887.60 | 17-JUL-08:10 |
| EnergyTransfer:Zone:G NE APARTMENT | 16.90 | 0.07 | 31-MAR-08:20 | 2160.19 | 21-DEC-23:10 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 7.26 | 0.00 | 19-JAN-11:20 | 2160.19 | 21-DEC-23:10 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 7.26 | 0.00 | 19-JAN-11:20 | 2160.19 | 21-DEC-23:10 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 9.64 | 0.00 | 01-JAN-00:10 | 1646.48 | 26-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 9.64 | 0.00 | 01-JAN-00:10 | 1646.48 | 26-JUN-17:30 |
| EnergyTransfer:Zone:G N1 APARTMENT | 11.81 | 0.01 | 22-FEB-12:30 | 1326.09 | 26-JUN-18:00 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 3.18 | 0.00 | 09-JAN-12:50 | 1303.35 | 23-DEC-08:00 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 3.18 | 0.00 | 09-JAN-12:50 | 1303.35 | 23-DEC-08:00 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 8.63 | 0.00 | 01-JAN-00:10 | 1326.09 | 26-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 8.63 | 0.00 | 01-JAN-00:10 | 1326.09 | 26-JUN-18:00 |
| EnergyTransfer:Zone:G N2 APARTMENT | 11.84 | 0.00 | 19-FEB-04:40 | 1318.26 | 26-JUN-18:00 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 3.18 | 0.00 | 09-JAN-12:40 | 1302.82 | 23-DEC-08:00 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 3.18 | 0.00 | 09-JAN-12:40 | 1302.82 | 23-DEC-08:00 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 8.66 | 0.00 | 01-JAN-00:10 | 1318.26 | 26-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 8.66 | 0.00 | 01-JAN-00:10 | 1318.26 | 26-JUN-18:00 |
| EnergyTransfer:Zone:G S1 APARTMENT | 16.25 | 0.00 | 04-MAY-09:30 | 1864.44 | 11-OCT-14:10 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.96 | 0.00 | 01-JAN-00:10 | 1020.30 | 21-DEC-08:10 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.96 | 0.00 | 01-JAN-00:10 | 1020.30 | 21-DEC-08:10 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 15.29 | 0.00 | 04-JAN-10:40 | 1864.44 | 11-OCT-14:10 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 15.29 | 0.00 | 04-JAN-10:40 | 1864.44 | 11-OCT-14:10 |
| EnergyTransfer:Zone:G S2 APARTMENT | 17.35 | 0.00 | 29-DEC-00:50 | 1929.70 | 11-OCT-14:10 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 1.22 | 0.00 | 01-JAN-00:10 | 1127.20 | 21-DEC-08:10 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 1.22 | 0.00 | 01-JAN-00:10 | 1127.20 | 21-DEC-08:10 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 16.13 | 0.00 | 03-JAN-05:20 | 1929.70 | 11-OCT-14:10 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 16.13 | 0.00 | 03-JAN-05:20 | 1929.70 | 11-OCT-14:10 |
| EnergyTransfer:Zone:M SW APARTMENT | 46.61 | 0.10 | 25-APR-02:20 | 5873.94 | 16-AUG-16:30 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 4.06 | 0.00 | 01-JAN-00:10 | 3805.41 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 4.06 | 0.00 | 01-JAN-00:10 | 3805.41 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 42.55 | 0.00 | 03-JAN-04:40 | 5873.94 | 16-AUG-16:30 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 42.55 | 0.00 | 03-JAN-04:40 | 5873.94 | 16-AUG-16:30 |
| EnergyTransfer:Zone:M NW APARTMENT | 36.08 | 0.02 | 11-APR-03:20 | 5545.15 | 26-JUN-17:30 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 8.38 | 0.00 | 01-JAN-14:00 | 4208.61 | 21-DEC-23:10 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 8.38 | 0.00 | 01-JAN-14:00 | 4208.61 | 21-DEC-23:10 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 27.70 | 0.00 | 01-JAN-00:10 | 5545.15 | 26-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 27.70 | 0.00 | 01-JAN-00:10 | 5545.15 | 26-JUN-17:30 |
| EnergyTransfer:Zone:M SE APARTMENT | 47.74 | 0.45 | 01-FEB-19:10 | 5233.96 | 28-SEP-13:40 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 4.07 | 0.00 | 01-JAN-00:10 | 3862.58 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 4.07 | 0.00 | 01-JAN-00:10 | 3862.58 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 43.66 | 0.00 | 03-JAN-05:00 | 5233.96 | 28-SEP-13:40 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 43.66 | 0.00 | 03-JAN-05:00 | 5233.96 | 28-SEP-13:40 |
| EnergyTransfer:Zone:M NE APARTMENT | 37.06 | 0.16 | 02-DEC-14:50 | 4337.20 | 21-DEC-23:10 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 8.30 | 0.00 | 01-JAN-08:50 | 4337.20 | 21-DEC-23:10 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 8.30 | 0.00 | 01-JAN-08:50 | 4337.20 | 21-DEC-23:10 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 28.76 | 0.00 | 01-JAN-00:10 | 4267.35 | 16-JUL-14:30 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 28.76 | 0.00 | 01-JAN-00:10 | 4267.35 | 16-JUL-14:30 |
| EnergyTransfer:Zone:M N1 APARTMENT | 28.15 | 0.06 | 02-NOV-11:30 | 3304.46 | 26-JUN-18:30 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 2.31 | 0.00 | 01-JAN-00:10 | 2214.82 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 2.31 | 0.00 | 01-JAN-00:10 | 2214.82 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 25.84 | 0.00 | 01-JAN-01:10 | 3304.46 | 26-JUN-18:30 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 25.84 | 0.00 | 01-JAN-01:10 | 3304.46 | 26-JUN-18:30 |
| EnergyTransfer:Zone:M N2 APARTMENT | 28.21 | 0.14 | 31-DEC-05:30 | 3282.45 | 26-JUN-18:30 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 2.32 | 0.00 | 01-JAN-00:10 | 2218.28 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 2.32 | 0.00 | 01-JAN-00:10 | 2218.28 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 25.90 | 0.00 | 01-JAN-01:10 | 3282.45 | 26-JUN-18:30 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 25.90 | 0.00 | 01-JAN-01:10 | 3282.45 | 26-JUN-18:30 |
| EnergyTransfer:Zone:M S1 APARTMENT | 43.36 | 0.27 | 05-JAN-19:40 | 4550.29 | 11-OCT-14:10 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.79 | 0.00 | 01-JAN-00:10 | 1817.47 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.79 | 0.00 | 01-JAN-00:10 | 1817.47 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 42.57 | 0.00 | 04-JAN-22:50 | 4550.29 | 11-OCT-14:10 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 42.57 | 0.00 | 04-JAN-22:50 | 4550.29 | 11-OCT-14:10 |
| EnergyTransfer:Zone:M S2 APARTMENT | 43.44 | 0.04 | 20-MAR-08:00 | 4551.18 | 11-OCT-14:10 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.79 | 0.00 | 01-JAN-00:10 | 1821.34 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.79 | 0.00 | 01-JAN-00:10 | 1821.34 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 42.65 | 0.00 | 04-JAN-22:50 | 4551.18 | 11-OCT-14:10 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 42.65 | 0.00 | 04-JAN-22:50 | 4551.18 | 11-OCT-14:10 |
| EnergyTransfer:Zone:T SW APARTMENT | 29.63 | 0.01 | 20-MAY-02:40 | 4168.19 | 16-AUG-16:20 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 9.83 | 0.00 | 01-JAN-09:10 | 3685.72 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 9.83 | 0.00 | 01-JAN-09:10 | 3685.72 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 19.80 | 0.00 | 01-JAN-00:10 | 4168.19 | 16-AUG-16:20 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 19.80 | 0.00 | 01-JAN-00:10 | 4168.19 | 16-AUG-16:20 |
| EnergyTransfer:Zone:T NW APARTMENT | 26.78 | 0.03 | 25-NOV-11:40 | 3888.58 | 26-JUN-17:20 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 13.66 | 0.00 | 01-JAN-15:10 | 3763.20 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 13.66 | 0.00 | 01-JAN-15:10 | 3763.20 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 13.12 | 0.00 | 01-JAN-00:10 | 3888.58 | 26-JUN-17:20 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 13.12 | 0.00 | 01-JAN-00:10 | 3888.58 | 26-JUN-17:20 |
| EnergyTransfer:Zone:T SE APARTMENT | 29.99 | 0.20 | 28-APR-22:30 | 3741.23 | 16-AUG-13:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 9.80 | 0.00 | 01-JAN-08:40 | 3696.97 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 9.80 | 0.00 | 01-JAN-08:40 | 3696.97 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 20.19 | 0.00 | 01-JAN-00:10 | 3741.23 | 16-AUG-13:00 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 20.19 | 0.00 | 01-JAN-00:10 | 3741.23 | 16-AUG-13:00 |
| EnergyTransfer:Zone:T NE APARTMENT | 26.99 | 0.05 | 19-MAY-03:30 | 3811.61 | 21-DEC-23:00 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 13.52 | 0.00 | 09-JAN-10:00 | 3811.61 | 21-DEC-23:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 13.52 | 0.00 | 09-JAN-10:00 | 3811.61 | 21-DEC-23:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 13.47 | 0.00 | 01-JAN-00:10 | 2954.67 | 16-JUL-14:30 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 13.47 | 0.00 | 01-JAN-00:10 | 2954.67 | 16-JUL-14:30 |
| EnergyTransfer:Zone:T N1 APARTMENT | 18.86 | 0.01 | 26-JAN-21:30 | 2542.17 | 22-DEC-04:00 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 7.93 | 0.00 | 08-JAN-14:50 | 2542.17 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 7.93 | 0.00 | 08-JAN-14:50 | 2542.17 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 10.93 | 0.00 | 01-JAN-00:10 | 2381.08 | 26-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 10.93 | 0.00 | 01-JAN-00:10 | 2381.08 | 26-JUN-17:30 |
| EnergyTransfer:Zone:T N2 APARTMENT | 18.91 | 0.03 | 13-DEC-12:00 | 2543.61 | 22-DEC-04:00 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 7.94 | 0.00 | 08-JAN-14:50 | 2543.61 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 7.94 | 0.00 | 08-JAN-14:50 | 2543.61 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 10.97 | 0.00 | 01-JAN-00:10 | 2357.33 | 26-JUN-17:20 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 10.97 | 0.00 | 01-JAN-00:10 | 2357.33 | 26-JUN-17:20 |
| EnergyTransfer:Zone:T S1 APARTMENT | 23.09 | 0.03 | 06-DEC-11:20 | 3039.94 | 28-SEP-13:40 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 4.92 | 0.00 | 01-JAN-00:10 | 2456.36 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 4.92 | 0.00 | 01-JAN-00:10 | 2456.36 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 18.17 | 0.00 | 01-JAN-00:20 | 3039.94 | 28-SEP-13:40 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 18.17 | 0.00 | 01-JAN-00:20 | 3039.94 | 28-SEP-13:40 |
| EnergyTransfer:Zone:T S2 APARTMENT | 23.17 | 0.04 | 31-MAR-02:40 | 3052.60 | 28-SEP-13:40 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 4.93 | 0.00 | 01-JAN-00:10 | 2457.87 | 22-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 4.93 | 0.00 | 01-JAN-00:10 | 2457.87 | 22-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 18.24 | 0.00 | 01-JAN-00:20 | 3052.60 | 28-SEP-13:40 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 18.24 | 0.00 | 01-JAN-00:20 | 3052.60 | 28-SEP-13:40 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 682.26 | 0.00 | 19-APR-22:40 | 89532.89 | 22-DEC-04:00 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 30-JUL-13:50 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 30-JUL-11:20 |
| HeatingCoils:EnergyTransfer | 277.85 | 0.00 | 19-JAN-14:50 | 89532.89 | 22-DEC-04:00 |
| CoolingCoils:EnergyTransfer | 404.41 | 0.00 | 01-JAN-00:10 | 87447.09 | 26-JUN-17:00 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 0.504 | -10.096 | 8.556 | -9.929 | 0.000 | 0.000 | 3.862 | 1.454 | 12.213 | 16.032 | 0.000 | 0.127 | 0.000 | 0.000 | -6.912 | 0.000 | -3.518 | -12.295 |
| G NW APARTMENT | 0.506 | -9.825 | 14.591 | -7.112 | 0.000 | 0.000 | 3.967 | 1.454 | 12.213 | 7.332 | 0.000 | 0.128 | 0.000 | 0.000 | -6.882 | 0.000 | -3.378 | -12.993 |
| OFFICE | 0.000 | 0.000 | 3.111 | -11.792 | 0.000 | 0.000 | 2.100 | 7.396 | 9.469 | 16.289 | 0.000 | 0.081 | 0.001 | 0.000 | -6.929 | 0.000 | -2.986 | -16.738 |
| G NE APARTMENT | 0.505 | -9.831 | 14.509 | -7.559 | 0.000 | 0.000 | 3.968 | 1.454 | 12.213 | 7.715 | 0.000 | 0.127 | 0.000 | 0.000 | -6.769 | 0.000 | -3.385 | -12.946 |
| G N1 APARTMENT | 0.506 | -9.861 | 10.044 | -6.132 | 0.000 | 0.000 | 3.957 | 1.454 | 12.213 | 2.486 | 0.000 | 0.077 | 0.000 | 0.000 | -4.339 | 0.000 | -2.257 | -8.148 |
| G N2 APARTMENT | 0.506 | -9.862 | 10.043 | -6.161 | 0.000 | 0.000 | 3.957 | 1.454 | 12.213 | 2.485 | 0.000 | 0.077 | 0.000 | 0.000 | -4.339 | 0.000 | -2.258 | -8.114 |
| G S1 APARTMENT | 0.504 | -10.231 | 4.628 | -9.230 | 0.000 | 0.000 | 3.828 | 1.454 | 12.213 | 11.236 | 0.000 | 0.077 | 0.000 | 0.000 | -4.274 | 0.000 | -2.392 | -7.812 |
| G S2 APARTMENT | 0.504 | -10.235 | 5.043 | -10.216 | 0.000 | 0.000 | 3.826 | 1.454 | 12.213 | 11.230 | 0.000 | 0.077 | 0.000 | 0.000 | -4.277 | 0.000 | -2.394 | -7.225 |
| M SW APARTMENT | 1.007 | -20.719 | 11.137 | -29.919 | 0.000 | 0.000 | 7.597 | 2.908 | 24.426 | 31.569 | 0.000 | 0.364 | 0.002 | 0.000 | -14.438 | 0.000 | -10.080 | -3.851 |
| M NW APARTMENT | 1.007 | -20.002 | 20.601 | -20.919 | 0.000 | 0.000 | 7.844 | 2.908 | 24.426 | 14.286 | 0.000 | 0.364 | 0.000 | 0.000 | -14.392 | 0.000 | -9.712 | -6.410 |
| M SE APARTMENT | 1.007 | -20.745 | 11.125 | -30.975 | 0.000 | 0.000 | 7.599 | 2.908 | 24.426 | 32.362 | 0.000 | 0.364 | 0.002 | 0.000 | -14.245 | 0.000 | -10.100 | -3.726 |
| M NE APARTMENT | 1.007 | -20.017 | 20.547 | -22.002 | 0.000 | 0.000 | 7.848 | 2.908 | 24.426 | 15.034 | 0.000 | 0.364 | 0.000 | 0.000 | -14.144 | 0.000 | -9.734 | -6.236 |
| M N1 APARTMENT | 1.007 | -20.086 | 12.448 | -16.894 | 0.000 | 0.000 | 7.821 | 2.908 | 24.426 | 4.806 | 0.000 | 0.219 | 0.000 | 0.000 | -9.059 | 0.000 | -6.422 | -1.175 |
| M N2 APARTMENT | 1.007 | -20.088 | 12.454 | -16.955 | 0.000 | 0.000 | 7.821 | 2.908 | 24.426 | 4.804 | 0.000 | 0.219 | 0.000 | 0.000 | -9.059 | 0.000 | -6.424 | -1.114 |
| M S1 APARTMENT | 1.007 | -21.055 | 5.074 | -26.807 | 0.000 | 0.000 | 7.505 | 2.908 | 24.426 | 22.198 | 0.000 | 0.219 | 0.196 | 0.000 | -8.917 | 0.000 | -6.753 | -0.000 |
| M S2 APARTMENT | 1.007 | -21.056 | 5.075 | -26.887 | 0.000 | 0.000 | 7.505 | 2.908 | 24.426 | 22.196 | 0.000 | 0.219 | 0.277 | 0.000 | -8.917 | 0.000 | -6.754 | -0.000 |
| T SW APARTMENT | 0.503 | -10.075 | 15.965 | -16.358 | 0.000 | 0.000 | 3.887 | 1.454 | 12.213 | 15.728 | 0.000 | 0.238 | 0.000 | 0.000 | -6.806 | 0.000 | -6.401 | -10.349 |
| T NW APARTMENT | 0.503 | -9.847 | 21.146 | -11.261 | 0.000 | 0.000 | 3.969 | 1.454 | 12.213 | 7.117 | 0.000 | 0.238 | 0.000 | 0.000 | -6.871 | 0.000 | -6.235 | -12.427 |
| T SE APARTMENT | 0.503 | -10.099 | 15.849 | -16.651 | 0.000 | 0.000 | 3.888 | 1.454 | 12.213 | 16.119 | 0.000 | 0.238 | 0.000 | 0.000 | -6.717 | 0.000 | -6.436 | -10.361 |
| T NE APARTMENT | 0.503 | -9.862 | 21.013 | -11.598 | 0.000 | 0.000 | 3.971 | 1.454 | 12.213 | 7.494 | 0.000 | 0.238 | 0.000 | 0.000 | -6.761 | 0.000 | -6.275 | -12.390 |
| T N1 APARTMENT | 0.503 | -9.870 | 15.169 | -8.801 | 0.000 | 0.000 | 3.960 | 1.454 | 12.213 | 2.401 | 0.000 | 0.144 | 0.000 | 0.000 | -4.339 | 0.000 | -4.084 | -8.752 |
| T N2 APARTMENT | 0.503 | -9.871 | 15.181 | -8.844 | 0.000 | 0.000 | 3.960 | 1.454 | 12.213 | 2.398 | 0.000 | 0.144 | 0.000 | 0.000 | -4.337 | 0.000 | -4.087 | -8.713 |
| T S1 APARTMENT | 0.503 | -10.170 | 10.241 | -13.820 | 0.000 | 0.000 | 3.862 | 1.454 | 12.213 | 11.084 | 0.000 | 0.144 | 0.000 | 0.000 | -4.203 | 0.000 | -4.240 | -7.067 |
| T S2 APARTMENT | 0.503 | -10.171 | 10.254 | -13.889 | 0.000 | 0.000 | 3.862 | 1.454 | 12.213 | 11.081 | 0.000 | 0.144 | 0.000 | 0.000 | -4.201 | 0.000 | -4.242 | -7.008 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.351 | 11.688 | 0.000 | 1.254 | 0.000 | 0.020 | 0.000 | 0.000 | -0.702 | 0.000 | -0.984 | -17.627 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.565 | 11.688 | 3.530 | 3.798 | 0.000 | 0.743 | 2.789 | 0.000 | -1.972 | 0.000 | -27.139 | -0.000 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 11.876 | 23.376 | 0.000 | 2.476 | 0.000 | 0.036 | 0.000 | 0.000 | -1.511 | 0.000 | -1.616 | -34.637 |
| Total Facility | 15.616 | -313.676 | 293.803 | -360.711 | 0.000 | 0.000 | 147.155 | 99.229 | 391.594 | 303.009 | 0.000 | 5.431 | 3.267 | 0.000 | -186.311 | 0.000 | -160.286 | -238.115 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 16-AUG-16:30 | 0.00 | 341.39 | 0.00 | -2675.55 | 0.00 | 0.00 | 0.00 | 86.80 | 588.62 | 1999.25 | 0.00 | 60.51 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -401.02 |
| G NW APARTMENT | 26-JUN-17:23 | 0.00 | 372.47 | 0.00 | -2435.96 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1917.48 | 0.00 | 88.09 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -793.37 |
| OFFICE | 03-JUL-07:01 | 0.00 | 0.00 | 0.00 | -6749.15 | 0.00 | 0.00 | 259.87 | 582.92 | 588.62 | 65.13 | 0.00 | 0.00 | 5281.47 | 0.00 | -0.00 | 0.00 | -28.85 | 0.00 |
| G NE APARTMENT | 26-JUN-17:27 | 0.00 | 372.46 | 0.00 | -2019.13 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 752.25 | 0.00 | 88.09 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -44.96 |
| G N1 APARTMENT | 26-JUN-18:00 | 0.00 | 372.47 | 0.00 | -1698.54 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 599.62 | 0.00 | 41.95 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -166.80 |
| G N2 APARTMENT | 26-JUN-18:00 | 0.00 | 372.47 | 0.00 | -1690.71 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 599.70 | 0.00 | 41.95 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -174.70 |
| G S1 APARTMENT | 11-OCT-14:10 | 0.00 | 92.57 | 0.00 | -1956.96 | 0.00 | 0.00 | 0.00 | 30.38 | 400.26 | 1819.31 | 0.00 | 14.22 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -399.79 |
| G S2 APARTMENT | 11-OCT-14:10 | 0.00 | 92.57 | 0.00 | -2022.22 | 0.00 | 0.00 | 0.00 | 30.38 | 400.26 | 1818.59 | 0.00 | 14.22 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -333.82 |
| M SW APARTMENT | 16-AUG-16:30 | 0.00 | 682.73 | 0.00 | -6557.01 | 0.00 | 0.00 | 0.00 | 173.60 | 1177.25 | 3989.25 | 0.00 | 173.63 | 360.56 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 26-JUN-17:27 | 0.00 | 744.89 | 0.00 | -6290.27 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 3821.87 | 0.00 | 252.81 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -231.89 |
| M SE APARTMENT | 28-SEP-13:40 | 0.00 | 373.17 | 0.00 | -5606.87 | 0.00 | 0.00 | 0.00 | 34.72 | 765.21 | 4093.24 | 0.00 | 99.25 | 241.28 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 16-JUL-14:30 | 0.00 | 631.02 | 0.00 | -4898.23 | 0.00 | 0.00 | 83.61 | 60.77 | 800.53 | 2404.24 | 0.00 | 364.63 | 553.44 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 26-JUN-18:30 | 0.00 | 688.28 | 0.00 | -3992.68 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1159.38 | 0.00 | 140.64 | 340.80 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 26-JUN-18:30 | 0.00 | 688.28 | 0.00 | -3970.67 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1159.56 | 0.00 | 140.64 | 318.61 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11-OCT-14:10 | 0.00 | 185.14 | 0.00 | -4735.30 | 0.00 | 0.00 | 0.00 | 60.77 | 800.53 | 3631.89 | 0.00 | 40.59 | 16.39 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11-OCT-14:10 | 0.00 | 185.14 | 0.00 | -4736.19 | 0.00 | 0.00 | 0.00 | 60.77 | 800.53 | 3631.86 | 0.00 | 40.59 | 17.30 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 16-AUG-16:17 | 0.00 | 345.59 | 0.00 | -4514.15 | 0.00 | 0.00 | 0.00 | 86.80 | 588.62 | 1997.92 | 0.00 | 105.79 | 1389.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 26-JUN-17:12 | 0.00 | 372.47 | 0.00 | -4261.20 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1903.44 | 0.00 | 178.42 | 955.57 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 16-AUG-13:00 | 0.00 | 328.13 | 0.00 | -4068.65 | 0.00 | 0.00 | 0.00 | 17.36 | 388.49 | 1705.86 | 0.00 | 158.25 | 1470.56 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 16-JUL-14:30 | 0.00 | 315.49 | 0.00 | -3270.07 | 0.00 | 0.00 | 41.81 | 30.38 | 400.26 | 1182.63 | 0.00 | 240.33 | 1059.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 26-JUN-17:23 | 0.00 | 372.50 | 0.00 | -2753.84 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 549.44 | 0.00 | 100.56 | 880.04 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 26-JUN-17:15 | 0.00 | 372.51 | 0.00 | -2730.06 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 531.47 | 0.00 | 107.62 | 867.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 28-SEP-13:40 | 0.00 | 186.59 | 0.00 | -3226.39 | 0.00 | 0.00 | 0.00 | 17.36 | 382.60 | 1839.91 | 0.00 | 39.35 | 760.57 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 28-SEP-13:40 | 0.00 | 186.59 | 0.00 | -3239.05 | 0.00 | 0.00 | 0.00 | 17.36 | 382.60 | 1839.78 | 0.00 | 39.35 | 773.36 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 16-AUG-16:07 | 0.00 | 10850.16 | 0.00 | -78971.63 | 0.00 | 0.00 | 1842.24 | 4289.87 | 18750.02 | 28083.77 | 0.00 | 4780.94 | 10374.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 21-DEC-08:05 | -1030.23 | 0.00 | 2942.41 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1080.92 | 0.00 | -329.73 | -916.06 |
| G NW APARTMENT | 23-DEC-08:00 | -1080.87 | 0.00 | 3218.67 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -820.39 | 0.00 | -452.26 | -1469.91 |
| OFFICE | 26-DEC-08:61 | 0.00 | 0.00 | 9222.55 | 0.00 | 0.00 | 0.00 | 418.55 | 582.92 | 588.62 | 1327.20 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -63.59 | -12076.25 |
| G NE APARTMENT | 21-DEC-23:10 | -987.16 | 0.00 | 3147.39 | 0.00 | 0.00 | 0.00 | 194.99 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -864.81 | 0.00 | -619.44 | -1234.08 |
| G N1 APARTMENT | 23-DEC-08:00 | -1080.99 | 0.00 | 2384.34 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -501.40 | 0.00 | -272.79 | -1133.92 |
| G N2 APARTMENT | 23-DEC-08:00 | -1080.99 | 0.00 | 2383.80 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -501.40 | 0.00 | -272.79 | -1133.38 |
| G S1 APARTMENT | 21-DEC-08:10 | -1030.27 | 0.00 | 2051.01 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -662.99 | 0.00 | -198.89 | -573.39 |
| G S2 APARTMENT | 21-DEC-08:09 | -1030.28 | 0.00 | 2157.85 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -661.33 | 0.00 | -198.89 | -681.88 |
| M SW APARTMENT | 22-DEC-04:00 | -2161.78 | 0.00 | 5967.17 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1946.69 | 0.00 | -1302.09 | -1411.32 |
| M NW APARTMENT | 21-DEC-23:10 | -1974.17 | 0.00 | 6182.86 | 0.00 | 0.00 | 0.00 | 389.98 | 43.40 | 682.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1744.86 | 0.00 | -1781.27 | -1798.74 |
| M SE APARTMENT | 22-DEC-04:00 | -2161.78 | 0.00 | 6024.34 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1920.62 | 0.00 | -1302.09 | -1494.56 |
| M NE APARTMENT | 21-DEC-23:10 | -1974.17 | 0.00 | 6311.45 | 0.00 | 0.00 | 0.00 | 389.98 | 43.40 | 682.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1767.32 | 0.00 | -1781.27 | -1904.88 |
| M N1 APARTMENT | 22-DEC-04:00 | -2162.02 | 0.00 | 4376.83 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1145.38 | 0.00 | -785.39 | -1138.75 |
| M N2 APARTMENT | 22-DEC-04:00 | -2162.02 | 0.00 | 4380.29 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1145.35 | 0.00 | -785.39 | -1142.24 |
| M S1 APARTMENT | 22-DEC-04:00 | -2162.02 | 0.00 | 3979.49 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1187.87 | 0.00 | -785.39 | -698.91 |
| M S2 APARTMENT | 22-DEC-04:00 | -2162.02 | 0.00 | 3983.36 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1187.82 | 0.00 | -785.39 | -702.83 |
| T SW APARTMENT | 22-DEC-04:00 | -1080.81 | 0.00 | 4766.51 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -950.28 | 0.00 | -862.00 | -2300.76 |
| T NW APARTMENT | 22-DEC-04:00 | -1080.81 | 0.00 | 4843.98 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -929.28 | 0.00 | -862.00 | -2399.25 |
| T SE APARTMENT | 22-DEC-04:00 | -1080.81 | 0.00 | 4777.76 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -936.88 | 0.00 | -862.00 | -2325.42 |
| T NE APARTMENT | 21-DEC-23:00 | -978.49 | 0.00 | 4790.16 | 0.00 | 0.00 | 0.00 | 194.99 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -853.85 | 0.00 | -1246.89 | -2375.93 |
| T N1 APARTMENT | 22-DEC-04:00 | -1080.94 | 0.00 | 3623.11 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -560.31 | 0.00 | -519.94 | -1889.27 |
| T N2 APARTMENT | 22-DEC-04:00 | -1080.94 | 0.00 | 3624.55 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -560.29 | 0.00 | -519.94 | -1890.72 |
| T S1 APARTMENT | 22-DEC-04:00 | -1080.94 | 0.00 | 3537.29 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -581.13 | 0.00 | -519.94 | -1782.63 |
| T S2 APARTMENT | 22-DEC-04:00 | -1080.94 | 0.00 | 3538.80 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -581.12 | 0.00 | -519.94 | -1784.16 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 21-DEC-08:61 | -31936.81 | 0.00 | 95450.39 | 0.00 | 0.00 | 0.00 | 2196.96 | 2872.71 | 12840.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -28284.58 | 0.00 | -14637.95 | -38500.96 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.4088 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4088 | 0.0635 | 1.0000 | Not calculated | 0.0260 | 0.0635 | ||
| SPLIT GNW | 0.3892 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3892 | 0.0667 | 1.0000 | Not calculated | 0.0260 | 0.0667 | ||
| SPLIT OFFICE | 0.4474 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4474 | 0.0852 | 1.0000 | Not calculated | 0.0381 | 0.0852 | ||
| SPLIT GNE | 0.3442 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3442 | 0.0754 | 1.0000 | Not calculated | 0.0260 | 0.0754 | ||
| SPLIT GN1 | 0.3151 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3151 | 0.0824 | 1.0000 | Not calculated | 0.0260 | 0.0824 | ||
| SPLIT GN2 | 0.3142 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3142 | 0.0826 | 1.0000 | Not calculated | 0.0260 | 0.0826 | ||
| SPLIT GS1 | 0.3367 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3367 | 0.0771 | 1.0000 | Not calculated | 0.0260 | 0.0771 | ||
| SPLIT GS2 | 0.3389 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3389 | 0.0766 | 1.0000 | Not calculated | 0.0260 | 0.0766 | ||
| SPLIT MSW | 1.0389 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 1.0389 | 0.0500 | 1.0000 | Not calculated | 0.0519 | 0.0500 | ||
| SPLIT MNW | 1.0089 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 1.0089 | 0.0514 | 1.0000 | Not calculated | 0.0519 | 0.0514 | ||
| SPLIT MSE | 0.9106 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9106 | 0.0570 | 1.0000 | Not calculated | 0.0519 | 0.0570 | ||
| SPLIT MNE | 0.8816 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8816 | 0.0589 | 1.0000 | Not calculated | 0.0519 | 0.0589 | ||
| SPLIT MN1 | 0.7912 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7912 | 0.0656 | 1.0000 | Not calculated | 0.0519 | 0.0656 | ||
| SPLIT MN2 | 0.7887 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7887 | 0.0658 | 1.0000 | Not calculated | 0.0519 | 0.0658 | ||
| SPLIT MS1 | 0.8268 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8268 | 0.0628 | 1.0000 | Not calculated | 0.0519 | 0.0628 | ||
| SPLIT MS2 | 0.8242 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8242 | 0.0630 | 1.0000 | Not calculated | 0.0519 | 0.0630 | ||
| SPLIT TSW | 0.5773 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5773 | 0.0450 | 1.0000 | Not calculated | 0.0260 | 0.0450 | ||
| SPLIT TNW | 0.5725 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5725 | 0.0453 | 1.0000 | Not calculated | 0.0260 | 0.0453 | ||
| SPLIT TSE | 0.4831 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4831 | 0.0537 | 1.0000 | Not calculated | 0.0260 | 0.0537 | ||
| SPLIT TNE | 0.4782 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4782 | 0.0543 | 1.0000 | Not calculated | 0.0260 | 0.0543 | ||
| SPLIT TN1 | 0.4490 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4490 | 0.0578 | 1.0000 | Not calculated | 0.0260 | 0.0578 | ||
| SPLIT TN2 | 0.4459 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4459 | 0.0582 | 1.0000 | Not calculated | 0.0260 | 0.0582 | ||
| SPLIT TS1 | 0.4554 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4554 | 0.0570 | 1.0000 | Not calculated | 0.0260 | 0.0570 | ||
| SPLIT TS2 | 0.4523 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4523 | 0.0574 | 1.0000 | Not calculated | 0.0260 | 0.0574 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.4088 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4088 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0635 | ||
| SPLIT GNW | 0.3892 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3892 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0667 | ||
| SPLIT OFFICE | 0.4474 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4474 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0852 | ||
| SPLIT GNE | 0.3442 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3442 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0754 | ||
| SPLIT GN1 | 0.3151 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3151 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0824 | ||
| SPLIT GN2 | 0.3142 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3142 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0826 | ||
| SPLIT GS1 | 0.3367 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3367 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0771 | ||
| SPLIT GS2 | 0.3389 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3389 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0766 | ||
| SPLIT MSW | 1.0389 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 1.0389 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0500 | ||
| SPLIT MNW | 1.0089 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 1.0089 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0514 | ||
| SPLIT MSE | 0.9106 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9106 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0570 | ||
| SPLIT MNE | 0.8816 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8816 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0589 | ||
| SPLIT MN1 | 0.7912 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7912 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0656 | ||
| SPLIT MN2 | 0.7887 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7887 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0658 | ||
| SPLIT MS1 | 0.8268 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8268 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0628 | ||
| SPLIT MS2 | 0.8242 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8242 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0630 | ||
| SPLIT TSW | 0.5773 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5773 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0450 | ||
| SPLIT TNW | 0.5725 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5725 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0453 | ||
| SPLIT TSE | 0.4831 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4831 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0537 | ||
| SPLIT TNE | 0.4782 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4782 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0543 | ||
| SPLIT TN1 | 0.4490 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4490 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0578 | ||
| SPLIT TN2 | 0.4459 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4459 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0582 | ||
| SPLIT TS1 | 0.4554 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4554 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0570 | ||
| SPLIT TS2 | 0.4523 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4523 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0574 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4088 | 0.4088 | 0.4088 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3892 | 0.3892 | 0.3892 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4474 | 0.4474 | 0.4474 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3442 | 0.3442 | 0.3442 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3151 | 0.3151 | 0.3151 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3142 | 0.3142 | 0.3142 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3367 | 0.3367 | 0.3367 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3389 | 0.3389 | 0.3389 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0389 | 1.0389 | 1.0389 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0089 | 1.0089 | 1.0089 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9106 | 0.9106 | 0.9106 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8816 | 0.8816 | 0.8816 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7912 | 0.7912 | 0.7912 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7887 | 0.7887 | 0.7887 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8268 | 0.8268 | 0.8268 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8242 | 0.8242 | 0.8242 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5773 | 0.5773 | 0.5773 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5725 | 0.5725 | 0.5725 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4831 | 0.4831 | 0.4831 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4782 | 0.4782 | 0.4782 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4490 | 0.4490 | 0.4490 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4459 | 0.4459 | 0.4459 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4554 | 0.4554 | 0.4554 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4523 | 0.4523 | 0.4523 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.4088 | 0.4088 | 0.4088 | 0.4088 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3892 | 0.3892 | 0.3892 | 0.3892 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4474 | 0.4474 | 0.4474 | 0.4474 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3442 | 0.3442 | 0.3442 | 0.3442 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.3151 | 0.3151 | 0.3151 | 0.3151 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.3142 | 0.3142 | 0.3142 | 0.3142 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3367 | 0.3367 | 0.3367 | 0.3367 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3389 | 0.3389 | 0.3389 | 0.3389 | 0.0260 | 1.0000 |
| SPLIT MSW | 1.0389 | 1.0389 | 1.0389 | 1.0389 | 0.0519 | 1.0000 |
| SPLIT MNW | 1.0089 | 1.0089 | 1.0089 | 1.0089 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.9106 | 0.9106 | 0.9106 | 0.9106 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.8816 | 0.8816 | 0.8816 | 0.8816 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.7912 | 0.7912 | 0.7912 | 0.7912 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.7887 | 0.7887 | 0.7887 | 0.7887 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.8268 | 0.8268 | 0.8268 | 0.8268 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.8242 | 0.8242 | 0.8242 | 0.8242 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5773 | 0.5773 | 0.5773 | 0.5773 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.5725 | 0.5725 | 0.5725 | 0.5725 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4831 | 0.4831 | 0.4831 | 0.4831 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4782 | 0.4782 | 0.4782 | 0.4782 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.4490 | 0.4490 | 0.4490 | 0.4490 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.4459 | 0.4459 | 0.4459 | 0.4459 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.4554 | 0.4554 | 0.4554 | 0.4554 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.4523 | 0.4523 | 0.4523 | 0.4523 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4088 | 0.4088 | 0.4088 | No | 0.0260 | 0.1901 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3892 | 0.3892 | 0.3892 | No | 0.0260 | 0.2028 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4474 | 0.4474 | 0.4474 | No | 0.0381 | 0.2302 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3442 | 0.3442 | 0.3442 | No | 0.0260 | 0.2028 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3151 | 0.3151 | 0.3151 | No | 0.0260 | 0.3274 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3142 | 0.3142 | 0.3142 | No | 0.0260 | 0.3274 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3367 | 0.3367 | 0.3367 | No | 0.0260 | 0.2952 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3389 | 0.3389 | 0.3389 | No | 0.0260 | 0.2934 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0389 | 1.0389 | 1.0389 | No | 0.0519 | 0.2113 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0089 | 1.0089 | 1.0089 | No | 0.0519 | 0.2304 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9106 | 0.9106 | 0.9106 | No | 0.0519 | 0.2113 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8816 | 0.8816 | 0.8816 | No | 0.0519 | 0.2304 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7912 | 0.7912 | 0.7912 | No | 0.0519 | 0.4324 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7887 | 0.7887 | 0.7887 | No | 0.0519 | 0.4324 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8268 | 0.8268 | 0.8268 | No | 0.0519 | 0.3705 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8242 | 0.8242 | 0.8242 | No | 0.0519 | 0.3705 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5773 | 0.5773 | 0.5773 | No | 0.0260 | 0.1225 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5725 | 0.5725 | 0.5725 | No | 0.0260 | 0.1294 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4831 | 0.4831 | 0.4831 | No | 0.0260 | 0.1225 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4782 | 0.4782 | 0.4782 | No | 0.0260 | 0.1294 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4490 | 0.4490 | 0.4490 | No | 0.0260 | 0.1873 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4459 | 0.4459 | 0.4459 | No | 0.0260 | 0.1873 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4554 | 0.4554 | 0.4554 | No | 0.0260 | 0.1733 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4523 | 0.4523 | 0.4523 | No | 0.0260 | 0.1733 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.4088 | 0.4088 | 0.4088 | 0.4088 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3892 | 0.3892 | 0.3892 | 0.3892 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4474 | 0.4474 | 0.4474 | 0.4474 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3442 | 0.3442 | 0.3442 | 0.3442 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.3151 | 0.3151 | 0.3151 | 0.3151 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.3142 | 0.3142 | 0.3142 | 0.3142 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3367 | 0.3367 | 0.3367 | 0.3367 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3389 | 0.3389 | 0.3389 | 0.3389 | 0.0260 | 1.0000 |
| SPLIT MSW | 1.0389 | 1.0389 | 1.0389 | 1.0389 | 0.0519 | 1.0000 |
| SPLIT MNW | 1.0089 | 1.0089 | 1.0089 | 1.0089 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.9106 | 0.9106 | 0.9106 | 0.9106 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.8816 | 0.8816 | 0.8816 | 0.8816 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.7912 | 0.7912 | 0.7912 | 0.7912 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.7887 | 0.7887 | 0.7887 | 0.7887 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.8268 | 0.8268 | 0.8268 | 0.8268 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.8242 | 0.8242 | 0.8242 | 0.8242 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5773 | 0.5773 | 0.5773 | 0.5773 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.5725 | 0.5725 | 0.5725 | 0.5725 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4831 | 0.4831 | 0.4831 | 0.4831 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4782 | 0.4782 | 0.4782 | 0.4782 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.4490 | 0.4490 | 0.4490 | 0.4490 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.4459 | 0.4459 | 0.4459 | 0.4459 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.4554 | 0.4554 | 0.4554 | 0.4554 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.4523 | 0.4523 | 0.4523 | 0.4523 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 347.32 | 111916.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 108.27 | 27189.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 50.00 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 102.13 | 9497.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 472.31 | 37932.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1290.60 |
| Natural Gas | 0.00 | 347.32 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1637.92 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 34.54 |
| Fans (All) | 32.58 |
| Service Water Heating | 150.68 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 411.73 |
| Subtotal | 411.73 |
| Natural Gas [MJ/m2] | |
| Space Heating | 110.80 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 110.80 |
| Subtotal | 110.80 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 6.06 |
| Space Heating | 21.20 |
| Space Cooling | 6.61 |
| Fans (All) | 6.24 |
| Service Water Heating | 28.84 |
| Receptacle Equipment | 28.00 |
| Miscellaneous | 3.05 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7709.50 | 1050.50 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 7219.17 | 1540.83 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 8648.33 | 111.67 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 5735.50 | 3024.50 | 0.00 | 0.00 | 0.00 |
| Min | 5735.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 3024.50 | 0.00 | 0.00 | 0.00 |
| Average | 8547.87 | 212.13 | 0.00 | 0.00 | 0.00 |
| Sum | 230792.50 | 5727.50 | 0.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 19601.50 | 3393.50 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 22727.17 | 267.83 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 15171.83 | 7823.17 | 0.00 | 0.00 | 0.00 |
| Min | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 22727.17 | 7823.17 | 0.00 | 0.00 | 0.00 |
| Average | 11912.98 | 425.35 | 0.00 | 0.00 | 0.00 |
| Sum | 321650.50 | 11484.50 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 8320.33 | 439.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8758.33 | 1.67 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8758.17 | 1.83 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 4359.50 | 4400.50 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 8099.83 | 660.17 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 1839.83 | 6906.50 | 13.67 | 0.00 | 0.00 |
| Min | 1839.83 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 6906.50 | 13.67 | 0.00 | 0.00 |
| Average | 8299.77 | 459.73 | 0.51 | 0.00 | 0.00 |
| Sum | 224093.67 | 12412.67 | 13.67 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6992.00 | 8.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11827.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10582.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11826.67 | 3.33 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10581.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 11464.50 | 11530.50 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 20554.83 | 2440.17 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 4769.00 | 18177.50 | 48.50 | 0.00 | 0.00 |
| Min | 4769.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 20554.83 | 18177.50 | 48.50 | 0.00 | 0.00 |
| Average | 11145.14 | 1191.40 | 1.80 | 0.00 | 0.00 |
| Sum | 300918.67 | 32167.83 | 48.50 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:28
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 0.846 |
| February | -0.25 |
| March | 4.824 |
| April | 6.083 |
| May | 13.735 |
| June | 22.164 |
| July | 22.707 |
| August | 21.737 |
| September | 18.538 |
| October | 7.117 |
| November | 3.031 |
| December | -1.01 |
| Annual Sum or Average | 10.017 |
| Minimum of Months | -1.01 |
| Maximum of Months | 22.707 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.561927E+09 | 712.40 | 14-JAN-16:45 | -7.3 | -7.3 | 82220935.22 | 70.27 | 21-JAN-16:19 | 9.67 | 3.99 |
| February | 0.372988E+09 | 550.30 | 16-FEB-19:00 | -1.0 | -2.4 | 72989250.41 | 70.32 | 18-FEB-17:40 | 15.00 | 5.84 |
| March | 0.424261E+09 | 1240.70 | 13-MAR-16:07 | 22.83 | 6.92 | 83867794.37 | 70.39 | 14-MAR-21:00 | 13.00 | 4.05 |
| April | 0.257878E+09 | 500.06 | 10-APR-21:00 | 1.00 | -3.1 | 79279844.86 | 70.37 | 08-APR-17:10 | 1.00 | -3.1 |
| May | 0.647821E+09 | 910.74 | 31-MAY-17:10 | 26.83 | 14.58 | 0.101357E+09 | 70.41 | 16-MAY-21:40 | 26.83 | 14.58 |
| June | 0.201725E+10 | 2102.55 | 26-JUN-17:20 | 37.70 | 15.21 | 0.119778E+09 | 70.36 | 11-JUN-03:39 | 37.70 | 15.21 |
| July | 0.218884E+10 | 1956.81 | 15-JUL-17:30 | 33.50 | 13.33 | 0.129126E+09 | 70.39 | 13-JUL-04:00 | 33.50 | 13.33 |
| August | 0.254643E+10 | 2334.03 | 16-AUG-16:30 | 36.50 | 16.44 | 0.123898E+09 | 70.33 | 23-AUG-20:40 | 23.33 | 12.90 |
| September | 0.252443E+10 | 2299.81 | 28-SEP-15:30 | 29.70 | 11.04 | 0.122360E+09 | 70.39 | 16-SEP-01:39 | 29.70 | 11.04 |
| October | 0.147165E+10 | 2296.12 | 11-OCT-15:20 | 25.33 | 9.18 | 0.108183E+09 | 70.39 | 10-OCT-03:39 | 25.33 | 9.18 |
| November | 0.950628E+09 | 1496.82 | 07-NOV-15:10 | 21.83 | 7.31 | 89285110.41 | 70.39 | 08-NOV-21:00 | 7.00 | 4.06 |
| December | 0.454840E+09 | 742.78 | 18-DEC-18:11 | -8.7 | -9.0 | 82812373.48 | 70.32 | 02-DEC-17:49 | -8.7 | -9.0 |
| Annual Sum or Average | 0.144189E+11 | 0.119516E+10 | ||||||||
| Minimum of Months | 0.257878E+09 | 500.06 | -8.7 | -9.0 | 72989250.41 | 70.27 | -8.7 | -9.0 | ||
| Maximum of Months | 0.254643E+10 | 2334.03 | 37.70 | 16.44 | 0.129126E+09 | 70.41 | 37.70 | 15.21 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 34911295.54 | 342.00 | 21-JAN-17:01 | 7.00 | 3.14 | 77999352.63 | 42.51 | 05-JAN-22:00 | 7.00 | 3.14 |
| February | 21932209.85 | 283.75 | 25-FEB-17:35 | 9.33 | 3.70 | 70425865.87 | 42.51 | 05-FEB-22:49 | 9.33 | 3.70 |
| March | 0.106506E+09 | 343.65 | 12-MAR-21:00 | 7.00 | 1.02 | 79939008.51 | 57.08 | 13-MAR-17:10 | 21.33 | 6.39 |
| April | 0.106907E+09 | 392.30 | 10-APR-19:00 | 5.00 | -1.2 | 77020190.79 | 55.29 | 20-APR-20:19 | 14.67 | 7.98 |
| May | 0.527901E+09 | 790.35 | 31-MAY-17:30 | 26.50 | 14.49 | 99072093.90 | 70.40 | 16-MAY-20:10 | 26.50 | 14.49 |
| June | 0.186951E+10 | 2063.49 | 26-JUN-17:23 | 37.70 | 15.21 | 0.123846E+09 | 70.39 | 13-JUN-03:49 | 37.70 | 15.21 |
| July | 0.198605E+10 | 1876.92 | 15-JUL-17:50 | 33.17 | 13.27 | 0.128600E+09 | 70.38 | 02-JUL-03:49 | 33.17 | 13.27 |
| August | 0.197927E+10 | 1982.04 | 16-AUG-17:10 | 35.67 | 16.25 | 0.128600E+09 | 70.40 | 13-AUG-04:00 | 35.67 | 16.25 |
| September | 0.165120E+10 | 1735.02 | 10-SEP-16:40 | 31.07 | 12.39 | 0.121048E+09 | 70.38 | 15-SEP-23:30 | 10.25 | 5.40 |
| October | 0.660476E+09 | 1037.88 | 11-OCT-16:10 | 23.67 | 8.58 | 95140047.37 | 70.33 | 10-OCT-21:00 | 23.67 | 8.58 |
| November | 0.203371E+09 | 411.67 | 18-NOV-17:17 | 4.33 | 3.98 | 77143469.97 | 52.40 | 09-NOV-21:10 | 4.33 | 3.98 |
| December | 36347215.32 | 324.13 | 02-DEC-19:40 | 7.67 | 1.38 | 78112042.65 | 42.75 | 02-DEC-18:10 | 7.67 | 1.38 |
| Annual Sum or Average | 0.918439E+10 | 0.115695E+10 | ||||||||
| Minimum of Months | 21932209.85 | 283.75 | 4.33 | -1.2 | 70425865.87 | 42.51 | 4.33 | 1.38 | ||
| Maximum of Months | 0.198605E+10 | 2063.49 | 37.70 | 16.25 | 0.128600E+09 | 70.40 | 37.70 | 16.25 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.660296E+09 | 1003.67 | 05-JAN-08:03 | -17.0 | -17.0 | 49255495.61 | 133.51 | 19-JAN-15:09 | 17.83 | 7.46 |
| February | 0.456025E+09 | 755.05 | 02-FEB-07:02 | -9.7 | -9.7 | 44237548.53 | 135.12 | 17-FEB-13:50 | 14.83 | 6.15 |
| March | 0.504351E+09 | 4649.88 | 15-MAR-08:62 | 9.83 | 2.38 | 59212164.87 | 162.79 | 15-MAR-08:09 | 9.83 | 2.38 |
| April | 0.289853E+09 | 750.08 | 21-APR-13:00 | 16.00 | 6.54 | 52108525.36 | 138.16 | 19-APR-14:50 | 16.00 | 6.54 |
| May | 0.462538E+09 | 5442.86 | 17-MAY-08:62 | 22.50 | 11.08 | 71096646.49 | 166.82 | 17-MAY-07:19 | 22.50 | 11.08 |
| June | 0.161041E+10 | 6504.64 | 19-JUN-07:02 | 22.98 | 13.93 | 77557444.07 | 217.47 | 26-JUN-07:10 | 22.07 | 12.41 |
| July | 0.158904E+10 | 6749.01 | 03-JUL-07:01 | 11.33 | 7.79 | 70562840.63 | 217.47 | 24-JUL-07:10 | 24.17 | 16.22 |
| August | 0.196859E+10 | 6630.50 | 15-AUG-07:01 | 14.00 | 10.42 | 81103270.75 | 217.47 | 07-AUG-07:10 | 14.00 | 10.42 |
| September | 0.175722E+10 | 6671.25 | 05-SEP-07:01 | 14.68 | 7.70 | 70200970.55 | 217.53 | 13-SEP-07:10 | 20.18 | 12.26 |
| October | 0.112230E+10 | 6244.70 | 10-OCT-08:62 | 14.67 | 6.36 | 64361175.95 | 181.16 | 11-OCT-07:10 | 13.67 | 5.23 |
| November | 0.799017E+09 | 5418.61 | 07-NOV-09:02 | 14.00 | 4.09 | 55298244.37 | 166.79 | 07-NOV-09:09 | 14.00 | 4.09 |
| December | 0.572882E+09 | 1106.14 | 22-DEC-08:03 | -20.0 | -20.0 | 47733806.66 | 135.06 | 14-DEC-11:39 | -20.0 | -20.0 |
| Annual Sum or Average | 0.117925E+11 | 0.742728E+09 | ||||||||
| Minimum of Months | 0.289853E+09 | 750.08 | -20.0 | -20.0 | 44237548.53 | 133.51 | -20.0 | -20.0 | ||
| Maximum of Months | 0.196859E+10 | 6749.01 | 22.98 | 13.93 | 81103270.75 | 217.53 | 24.17 | 16.22 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 26639535.39 | 253.45 | 20-JAN-17:25 | 10.50 | 4.70 | 77937052.45 | 42.51 | 05-JAN-22:00 | 10.50 | 4.70 |
| February | 20394658.19 | 248.67 | 18-FEB-18:50 | 10.67 | 4.43 | 70396372.44 | 42.51 | 05-FEB-22:49 | 10.67 | 4.43 |
| March | 0.110780E+09 | 341.24 | 16-MAR-06:09 | 7.00 | 0.72 | 79767034.58 | 57.16 | 14-MAR-20:40 | 7.00 | 0.72 |
| April | 0.123810E+09 | 377.99 | 21-APR-06:03 | 5.67 | 3.92 | 76982644.68 | 55.46 | 20-APR-20:30 | 5.67 | 3.92 |
| May | 0.553858E+09 | 630.55 | 17-MAY-16:05 | 25.83 | 11.36 | 99920558.95 | 70.38 | 17-MAY-20:40 | 17.33 | 8.34 |
| June | 0.194624E+10 | 1646.69 | 26-JUN-17:27 | 37.70 | 15.21 | 0.123867E+09 | 70.40 | 12-JUN-03:39 | 37.70 | 15.21 |
| July | 0.214275E+10 | 1634.42 | 16-JUL-14:30 | 35.50 | 14.51 | 0.128611E+09 | 70.39 | 05-JUL-03:00 | 35.50 | 14.51 |
| August | 0.211842E+10 | 1547.17 | 16-AUG-17:06 | 35.67 | 16.25 | 0.128672E+09 | 70.38 | 13-AUG-02:20 | 35.67 | 16.25 |
| September | 0.171636E+10 | 1489.24 | 09-SEP-15:10 | 29.43 | 13.15 | 0.121165E+09 | 70.38 | 17-SEP-02:39 | 12.70 | 7.04 |
| October | 0.651912E+09 | 745.91 | 11-OCT-16:05 | 23.67 | 8.58 | 93990788.93 | 70.38 | 09-OCT-20:30 | 23.67 | 8.58 |
| November | 0.195039E+09 | 395.42 | 10-NOV-06:30 | 5.00 | 4.22 | 77023495.48 | 52.56 | 09-NOV-21:10 | 5.00 | 4.22 |
| December | 30013929.40 | 307.99 | 04-DEC-18:50 | 8.33 | 3.01 | 78022256.74 | 42.51 | 21-DEC-22:00 | -18.0 | -18.4 |
| Annual Sum or Average | 0.963621E+10 | 0.115635E+10 | ||||||||
| Minimum of Months | 20394658.19 | 248.67 | 5.00 | 0.72 | 70396372.44 | 42.51 | -18.0 | -18.4 | ||
| Maximum of Months | 0.214275E+10 | 1646.69 | 37.70 | 16.25 | 0.128672E+09 | 70.40 | 37.70 | 16.25 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 72768215.27 | 339.94 | 25-JAN-17:45 | 7.17 | 2.00 | 77980529.87 | 42.51 | 05-JAN-22:00 | 7.17 | 2.00 |
| February | 38223570.21 | 268.56 | 18-FEB-19:00 | 10.00 | 4.18 | 70408803.41 | 42.51 | 05-FEB-22:49 | 10.00 | 4.18 |
| March | 0.142733E+09 | 370.98 | 17-MAR-06:10 | 6.00 | 5.12 | 79917099.81 | 56.80 | 14-MAR-20:40 | 6.00 | 5.12 |
| April | 0.172719E+09 | 378.02 | 21-APR-06:03 | 5.67 | 3.92 | 76879438.30 | 54.46 | 20-APR-20:19 | 5.67 | 3.92 |
| May | 0.561776E+09 | 503.87 | 12-MAY-03:00 | 1.00 | 0.07 | 0.104671E+09 | 70.34 | 17-MAY-20:49 | 17.17 | 8.27 |
| June | 0.159654E+10 | 1326.09 | 26-JUN-18:00 | 37.70 | 15.21 | 0.124255E+09 | 70.39 | 01-JUN-23:00 | 37.70 | 15.21 |
| July | 0.179015E+10 | 1248.56 | 15-JUL-18:00 | 33.00 | 13.24 | 0.128741E+09 | 70.39 | 03-JUL-03:49 | 33.00 | 13.24 |
| August | 0.170883E+10 | 1217.42 | 16-AUG-17:25 | 35.00 | 15.76 | 0.128743E+09 | 70.38 | 23-AUG-03:20 | 12.00 | 9.42 |
| September | 0.144659E+10 | 1125.93 | 10-SEP-17:15 | 30.13 | 12.08 | 0.122174E+09 | 70.40 | 17-SEP-03:49 | 11.37 | 6.76 |
| October | 0.704444E+09 | 625.96 | 11-OCT-16:02 | 23.67 | 8.58 | 97871478.80 | 70.37 | 01-OCT-00:30 | 23.67 | 8.58 |
| November | 0.318313E+09 | 523.25 | 10-NOV-17:20 | 0.00 | -0.0 | 77355936.91 | 55.21 | 09-NOV-21:10 | 0.00 | -0.0 |
| December | 73097037.27 | 347.20 | 02-DEC-19:50 | 6.83 | 0.91 | 78103867.12 | 43.49 | 04-DEC-21:10 | 7.00 | 0.68 |
| Annual Sum or Average | 0.862617E+10 | 0.116710E+10 | ||||||||
| Minimum of Months | 38223570.21 | 268.56 | 0.00 | -0.0 | 70408803.41 | 42.51 | 0.00 | -0.0 | ||
| Maximum of Months | 0.179015E+10 | 1326.09 | 37.70 | 15.76 | 0.128743E+09 | 70.40 | 37.70 | 15.21 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 72067916.78 | 339.70 | 25-JAN-17:45 | 7.17 | 2.00 | 77978625.10 | 42.51 | 05-JAN-22:00 | 7.17 | 2.00 |
| February | 38563307.91 | 268.52 | 18-FEB-19:00 | 10.00 | 4.18 | 70408837.29 | 42.51 | 05-FEB-22:49 | 10.00 | 4.18 |
| March | 0.143053E+09 | 371.25 | 17-MAR-06:10 | 6.00 | 5.12 | 79935997.25 | 56.88 | 14-MAR-20:40 | 6.00 | 5.12 |
| April | 0.175214E+09 | 378.03 | 21-APR-06:03 | 5.67 | 3.92 | 76902346.48 | 54.66 | 20-APR-20:19 | 5.67 | 3.92 |
| May | 0.565305E+09 | 512.18 | 17-MAY-16:05 | 25.83 | 11.36 | 0.104895E+09 | 70.40 | 17-MAY-23:30 | 17.00 | 8.20 |
| June | 0.160138E+10 | 1318.26 | 26-JUN-18:00 | 37.70 | 15.21 | 0.124253E+09 | 70.39 | 11-JUN-04:30 | 37.70 | 15.21 |
| July | 0.179813E+10 | 1249.75 | 16-JUL-16:04 | 34.33 | 14.03 | 0.128741E+09 | 70.39 | 04-JUL-01:39 | 34.33 | 14.03 |
| August | 0.171654E+10 | 1207.69 | 16-AUG-17:15 | 35.33 | 16.00 | 0.128744E+09 | 70.37 | 23-AUG-03:09 | 12.00 | 9.51 |
| September | 0.145124E+10 | 1119.54 | 10-SEP-17:15 | 30.13 | 12.08 | 0.122192E+09 | 70.39 | 17-SEP-03:49 | 11.37 | 6.76 |
| October | 0.704308E+09 | 621.70 | 11-OCT-16:02 | 23.67 | 8.58 | 97769267.65 | 70.36 | 01-OCT-00:20 | 23.67 | 8.58 |
| November | 0.317597E+09 | 523.25 | 10-NOV-17:06 | 0.00 | -0.0 | 77352293.13 | 55.22 | 09-NOV-21:10 | 0.00 | -0.0 |
| December | 72429761.06 | 346.91 | 02-DEC-19:50 | 6.83 | 0.91 | 78098806.10 | 43.34 | 04-DEC-21:10 | 7.00 | 0.68 |
| Annual Sum or Average | 0.865582E+10 | 0.116727E+10 | ||||||||
| Minimum of Months | 38563307.91 | 268.52 | 0.00 | -0.0 | 70408837.29 | 42.51 | 0.00 | -0.0 | ||
| Maximum of Months | 0.179813E+10 | 1318.26 | 37.70 | 16.00 | 0.128744E+09 | 70.40 | 37.70 | 15.21 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.926923E+09 | 757.68 | 14-JAN-18:00 | -9.0 | -9.0 | 87513541.86 | 70.38 | 22-JAN-16:30 | 7.50 | 4.34 |
| February | 0.606524E+09 | 618.80 | 12-FEB-14:30 | -5.5 | -8.4 | 75825347.93 | 70.40 | 26-FEB-16:30 | 17.00 | 4.86 |
| March | 0.597971E+09 | 1118.46 | 15-MAR-14:10 | 20.83 | 6.19 | 86241139.08 | 70.37 | 14-MAR-23:30 | 20.83 | 6.19 |
| April | 0.449102E+09 | 538.20 | 10-APR-23:20 | -0.7 | -3.6 | 80411314.19 | 69.00 | 08-APR-17:49 | -0.7 | -3.6 |
| May | 0.693886E+09 | 699.61 | 18-MAY-14:10 | 23.83 | 11.33 | 0.108047E+09 | 70.41 | 18-MAY-00:30 | 23.83 | 11.33 |
| June | 0.175710E+10 | 1360.15 | 26-JUN-17:05 | 37.70 | 15.21 | 0.120201E+09 | 70.39 | 02-JUN-01:39 | 37.70 | 15.21 |
| July | 0.200879E+10 | 1358.23 | 23-JUL-13:50 | 34.83 | 16.78 | 0.129254E+09 | 70.38 | 04-JUL-02:30 | 34.83 | 16.78 |
| August | 0.229784E+10 | 1612.82 | 31-AUG-15:10 | 31.00 | 11.93 | 0.123958E+09 | 70.33 | 23-AUG-19:40 | 31.00 | 11.93 |
| September | 0.236303E+10 | 1829.82 | 28-SEP-14:10 | 30.32 | 11.26 | 0.123192E+09 | 70.39 | 16-SEP-05:00 | 30.32 | 11.26 |
| October | 0.163104E+10 | 1864.44 | 11-OCT-14:10 | 26.83 | 9.68 | 0.112329E+09 | 70.40 | 09-OCT-03:00 | 26.83 | 9.68 |
| November | 0.119337E+10 | 1346.30 | 07-NOV-14:00 | 22.00 | 7.34 | 96301990.49 | 70.40 | 15-NOV-18:10 | 7.67 | 3.54 |
| December | 0.762031E+09 | 882.25 | 18-DEC-23:10 | -14.2 | -14.4 | 86320964.06 | 70.38 | 04-DEC-18:10 | -14.2 | -14.4 |
| Annual Sum or Average | 0.152876E+11 | 0.122960E+10 | ||||||||
| Minimum of Months | 0.449102E+09 | 538.20 | -14.2 | -14.4 | 75825347.93 | 69.00 | -14.2 | -14.4 | ||
| Maximum of Months | 0.236303E+10 | 1864.44 | 37.70 | 16.78 | 0.129254E+09 | 70.41 | 37.70 | 16.78 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.873726E+09 | 754.86 | 14-JAN-18:00 | -9.0 | -9.0 | 87174874.04 | 70.39 | 22-JAN-16:10 | 8.50 | 4.50 |
| February | 0.575007E+09 | 612.56 | 28-FEB-06:10 | -3.0 | -3.4 | 75700345.26 | 70.29 | 18-FEB-18:10 | -3.0 | -3.4 |
| March | 0.594867E+09 | 1170.17 | 15-MAR-14:10 | 20.83 | 6.19 | 86259427.10 | 70.37 | 16-MAR-21:00 | 10.00 | 4.14 |
| April | 0.444286E+09 | 545.79 | 10-APR-23:30 | -1.0 | -3.8 | 80466170.78 | 68.72 | 08-APR-17:49 | -1.0 | -3.8 |
| May | 0.729476E+09 | 760.92 | 18-MAY-14:10 | 23.83 | 11.33 | 0.109395E+09 | 70.41 | 07-MAY-19:40 | 23.83 | 11.33 |
| June | 0.193857E+10 | 1447.71 | 26-JUN-17:17 | 37.70 | 15.21 | 0.120287E+09 | 70.39 | 02-JUN-04:49 | 37.70 | 15.21 |
| July | 0.224612E+10 | 1503.54 | 23-JUL-13:50 | 34.83 | 16.78 | 0.129271E+09 | 70.38 | 04-JUL-07:10 | 34.83 | 16.78 |
| August | 0.253185E+10 | 1676.59 | 31-AUG-15:10 | 31.00 | 11.93 | 0.123963E+09 | 70.33 | 23-AUG-19:40 | 31.00 | 11.93 |
| September | 0.257242E+10 | 1890.04 | 28-SEP-14:10 | 30.32 | 11.26 | 0.123316E+09 | 70.36 | 25-SEP-04:10 | 30.32 | 11.26 |
| October | 0.171079E+10 | 1929.70 | 11-OCT-14:10 | 26.83 | 9.68 | 0.112886E+09 | 70.38 | 21-OCT-00:30 | 5.50 | -0.8 |
| November | 0.119165E+10 | 1359.21 | 07-NOV-14:00 | 22.00 | 7.34 | 96349070.52 | 70.38 | 19-NOV-19:00 | 3.00 | 1.10 |
| December | 0.716280E+09 | 879.13 | 18-DEC-23:00 | -14.0 | -14.3 | 85978956.26 | 70.31 | 04-DEC-18:10 | -14.0 | -14.3 |
| Annual Sum or Average | 0.161250E+11 | 0.123105E+10 | ||||||||
| Minimum of Months | 0.444286E+09 | 545.79 | -14.0 | -14.3 | 75700345.26 | 68.72 | -14.0 | -14.3 | ||
| Maximum of Months | 0.257242E+10 | 1929.70 | 37.70 | 16.78 | 0.129271E+09 | 70.41 | 37.70 | 16.78 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.121148E+10 | 1943.93 | 20-JAN-15:20 | 19.33 | 7.07 | 93057846.11 | 70.33 | 15-JAN-16:49 | 19.33 | 7.07 |
| February | 0.911507E+09 | 1713.78 | 18-FEB-14:30 | 19.50 | 7.87 | 80961025.86 | 70.27 | 25-FEB-16:19 | 12.00 | 4.01 |
| March | 0.110926E+10 | 2617.41 | 13-MAR-16:07 | 22.83 | 6.92 | 92012100.74 | 70.33 | 26-MAR-18:40 | 11.00 | 4.24 |
| April | 0.819245E+09 | 1776.74 | 08-APR-17:13 | 15.33 | 4.96 | 91114166.54 | 70.33 | 06-APR-20:10 | 15.33 | 4.96 |
| May | 0.158758E+10 | 2144.58 | 31-MAY-16:25 | 27.50 | 14.75 | 0.117898E+09 | 70.32 | 06-MAY-09:00 | 27.50 | 14.75 |
| June | 0.299745E+10 | 2798.21 | 26-JUN-17:03 | 37.70 | 15.21 | 0.120370E+09 | 70.31 | 30-JUN-23:30 | 23.20 | 11.06 |
| July | 0.306330E+10 | 2647.97 | 15-JUL-17:30 | 33.50 | 13.33 | 0.129257E+09 | 70.32 | 05-JUL-05:49 | 33.50 | 13.33 |
| August | 0.315494E+10 | 2936.97 | 16-AUG-16:30 | 36.50 | 16.44 | 0.123935E+09 | 70.32 | 19-AUG-08:00 | 24.00 | 11.71 |
| September | 0.274395E+10 | 2892.28 | 28-SEP-15:20 | 29.60 | 11.04 | 0.122015E+09 | 70.33 | 30-SEP-23:40 | 10.60 | 8.89 |
| October | 0.169312E+10 | 2902.46 | 11-OCT-15:10 | 25.67 | 9.32 | 0.107638E+09 | 70.32 | 09-OCT-01:19 | 25.67 | 9.32 |
| November | 0.124920E+10 | 2330.47 | 07-NOV-15:10 | 21.83 | 7.31 | 94046224.21 | 70.33 | 09-NOV-21:00 | 8.00 | 6.33 |
| December | 0.735513E+09 | 1500.68 | 02-DEC-15:00 | 22.00 | 7.91 | 86699765.82 | 70.27 | 17-DEC-16:19 | 15.00 | 4.44 |
| Annual Sum or Average | 0.212765E+11 | 0.125900E+10 | ||||||||
| Minimum of Months | 0.735513E+09 | 1500.68 | 15.33 | 4.96 | 80961025.86 | 70.27 | 8.00 | 4.01 | ||
| Maximum of Months | 0.315494E+10 | 2936.97 | 37.70 | 16.44 | 0.129257E+09 | 70.33 | 33.50 | 14.75 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.237511E+09 | 531.58 | 22-JAN-19:10 | -0.3 | -0.3 | 79260248.05 | 49.91 | 20-JAN-22:10 | -0.3 | -0.3 |
| February | 0.199278E+09 | 487.39 | 20-FEB-18:35 | 1.33 | -0.3 | 71561339.42 | 53.70 | 18-FEB-21:10 | 1.33 | -0.3 |
| March | 0.414613E+09 | 1089.68 | 15-MAR-16:02 | 18.67 | 5.26 | 88527686.75 | 70.30 | 13-MAR-21:10 | 18.67 | 5.26 |
| April | 0.496176E+09 | 728.49 | 20-APR-17:30 | 18.00 | 8.44 | 85742031.01 | 70.27 | 20-APR-20:10 | 14.83 | 7.98 |
| May | 0.132805E+10 | 2049.57 | 31-MAY-17:30 | 26.50 | 14.49 | 0.119172E+09 | 70.33 | 18-MAY-03:09 | 26.50 | 14.49 |
| June | 0.283875E+10 | 2772.72 | 26-JUN-17:27 | 37.70 | 15.21 | 0.124578E+09 | 70.31 | 03-JUN-03:00 | 37.70 | 15.21 |
| July | 0.283279E+10 | 2564.18 | 15-JUL-17:40 | 33.33 | 13.30 | 0.128758E+09 | 70.32 | 10-JUL-21:40 | 33.33 | 13.30 |
| August | 0.253747E+10 | 2519.70 | 16-AUG-16:40 | 36.33 | 16.46 | 0.128695E+09 | 70.32 | 31-AUG-20:40 | 23.67 | 11.83 |
| September | 0.181304E+10 | 2109.92 | 12-SEP-16:30 | 30.25 | 14.03 | 0.120899E+09 | 70.32 | 18-SEP-01:39 | 12.20 | 7.13 |
| October | 0.724078E+09 | 1440.90 | 11-OCT-16:05 | 23.67 | 8.58 | 96782442.47 | 70.33 | 11-OCT-21:49 | 8.33 | 4.20 |
| November | 0.323310E+09 | 459.79 | 18-NOV-19:30 | 2.50 | 2.50 | 79398930.20 | 60.37 | 09-NOV-21:10 | 2.50 | 2.50 |
| December | 0.102514E+09 | 395.16 | 02-DEC-23:00 | 5.00 | 0.19 | 78667881.68 | 49.10 | 02-DEC-18:10 | 5.00 | 0.19 |
| Annual Sum or Average | 0.138476E+11 | 0.120204E+10 | ||||||||
| Minimum of Months | 0.102514E+09 | 395.16 | -0.3 | -0.3 | 71561339.42 | 49.10 | -0.3 | -0.3 | ||
| Maximum of Months | 0.283875E+10 | 2772.72 | 37.70 | 16.46 | 0.128758E+09 | 70.33 | 37.70 | 15.21 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.118942E+10 | 1765.01 | 20-JAN-14:00 | 21.00 | 6.96 | 92795054.74 | 70.32 | 25-JAN-19:19 | 4.67 | 1.03 |
| February | 0.912721E+09 | 1653.18 | 18-FEB-13:30 | 20.00 | 7.73 | 80887694.45 | 70.33 | 20-FEB-16:30 | 6.00 | 1.16 |
| March | 0.113818E+10 | 2322.63 | 14-MAR-13:00 | 24.00 | 7.90 | 91616108.67 | 70.32 | 10-MAR-22:00 | 24.00 | 7.90 |
| April | 0.860591E+09 | 1536.64 | 21-APR-12:00 | 14.00 | 5.98 | 91311540.71 | 70.33 | 27-APR-18:10 | 16.50 | 9.35 |
| May | 0.165966E+10 | 1809.75 | 16-MAY-13:20 | 27.33 | 12.20 | 0.118016E+09 | 70.33 | 29-MAY-00:10 | 11.00 | 8.66 |
| June | 0.308584E+10 | 2278.64 | 30-JUN-14:00 | 36.10 | 14.44 | 0.120374E+09 | 70.31 | 30-JUN-23:30 | 23.20 | 11.06 |
| July | 0.323675E+10 | 2321.17 | 18-JUL-13:00 | 35.00 | 13.52 | 0.129255E+09 | 70.32 | 15-JUL-22:19 | 35.00 | 13.52 |
| August | 0.330769E+10 | 2560.51 | 31-AUG-13:00 | 30.00 | 11.96 | 0.123950E+09 | 70.32 | 23-AUG-19:40 | 30.00 | 11.96 |
| September | 0.282260E+10 | 2616.98 | 28-SEP-13:40 | 30.50 | 11.31 | 0.122087E+09 | 70.33 | 20-SEP-01:49 | 30.50 | 11.31 |
| October | 0.166352E+10 | 2524.46 | 11-OCT-13:30 | 26.50 | 9.59 | 0.107456E+09 | 70.31 | 10-OCT-01:10 | 26.50 | 9.59 |
| November | 0.122849E+10 | 2063.33 | 07-NOV-13:30 | 21.00 | 7.19 | 93529461.98 | 70.31 | 17-NOV-20:10 | 7.00 | 2.40 |
| December | 0.726213E+09 | 1174.11 | 02-DEC-14:30 | 21.50 | 7.52 | 86565721.16 | 70.28 | 04-DEC-18:30 | 9.00 | 3.48 |
| Annual Sum or Average | 0.218317E+11 | 0.125784E+10 | ||||||||
| Minimum of Months | 0.726213E+09 | 1174.11 | 14.00 | 5.98 | 80887694.45 | 70.28 | 4.67 | 1.03 | ||
| Maximum of Months | 0.330769E+10 | 2616.98 | 36.10 | 14.44 | 0.129255E+09 | 70.33 | 35.00 | 13.52 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.213802E+09 | 483.28 | 21-JAN-20:00 | 2.00 | 2.00 | 78937225.38 | 48.68 | 20-JAN-22:10 | 2.00 | 2.00 |
| February | 0.207023E+09 | 500.64 | 28-FEB-08:25 | 0.00 | -0.5 | 71518062.92 | 53.45 | 18-FEB-21:10 | 0.00 | -0.5 |
| March | 0.416051E+09 | 894.14 | 15-MAR-10:00 | 15.00 | 4.23 | 88339312.40 | 70.31 | 13-MAR-20:49 | 15.00 | 4.23 |
| April | 0.532824E+09 | 761.61 | 21-APR-09:40 | 12.00 | 5.66 | 86034482.30 | 70.27 | 20-APR-20:10 | 12.00 | 5.66 |
| May | 0.139602E+10 | 1479.56 | 16-MAY-16:17 | 26.33 | 11.90 | 0.119417E+09 | 70.33 | 28-MAY-22:40 | 12.00 | 8.63 |
| June | 0.292756E+10 | 2108.32 | 26-JUN-17:30 | 37.70 | 15.21 | 0.124573E+09 | 70.31 | 03-JUN-03:00 | 37.70 | 15.21 |
| July | 0.300601E+10 | 2133.67 | 16-JUL-14:30 | 35.50 | 14.51 | 0.128746E+09 | 70.32 | 15-JUL-22:19 | 35.50 | 14.51 |
| August | 0.268807E+10 | 1870.65 | 16-AUG-17:08 | 35.67 | 16.25 | 0.128728E+09 | 70.33 | 13-AUG-02:49 | 35.67 | 16.25 |
| September | 0.188079E+10 | 1680.14 | 09-SEP-15:10 | 29.43 | 13.15 | 0.121004E+09 | 70.32 | 06-SEP-02:09 | 29.43 | 13.15 |
| October | 0.710068E+09 | 968.84 | 11-OCT-15:10 | 25.67 | 9.32 | 95511765.51 | 70.29 | 10-OCT-23:19 | 25.67 | 9.32 |
| November | 0.310742E+09 | 442.57 | 10-NOV-12:50 | 3.17 | 3.17 | 79149921.94 | 60.65 | 09-NOV-21:10 | 3.17 | 3.17 |
| December | 92140800.22 | 381.20 | 02-DEC-20:00 | 6.00 | 0.43 | 78453028.85 | 47.02 | 02-DEC-18:10 | 6.00 | 0.43 |
| Annual Sum or Average | 0.143811E+11 | 0.120041E+10 | ||||||||
| Minimum of Months | 92140800.22 | 381.20 | 0.00 | -0.5 | 71518062.92 | 47.02 | 0.00 | -0.5 | ||
| Maximum of Months | 0.300601E+10 | 2133.67 | 37.70 | 16.25 | 0.128746E+09 | 70.33 | 37.70 | 16.25 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.438686E+09 | 574.47 | 22-JAN-20:00 | -2.0 | -2.0 | 79704586.46 | 51.50 | 20-JAN-22:10 | -2.0 | -2.0 |
| February | 0.307149E+09 | 550.70 | 19-FEB-22:00 | -1.0 | -1.0 | 71725597.23 | 54.27 | 18-FEB-21:10 | -1.0 | -1.0 |
| March | 0.513342E+09 | 646.57 | 16-MAR-17:20 | 15.33 | 5.20 | 88972520.91 | 70.30 | 15-MAR-22:19 | 15.33 | 5.20 |
| April | 0.657258E+09 | 572.53 | 10-APR-24:00 | -2.0 | -4.4 | 87150773.48 | 70.27 | 20-APR-20:40 | 14.33 | 7.97 |
| May | 0.126347E+10 | 1207.49 | 31-MAY-18:00 | 26.00 | 14.34 | 0.121682E+09 | 70.33 | 29-MAY-00:30 | 26.00 | 14.34 |
| June | 0.223995E+10 | 1652.23 | 26-JUN-18:30 | 36.60 | 14.84 | 0.124612E+09 | 70.31 | 30-JUN-23:30 | 23.20 | 11.06 |
| July | 0.233413E+10 | 1558.60 | 15-JUL-18:00 | 33.00 | 13.24 | 0.128774E+09 | 70.32 | 15-JUL-22:19 | 23.00 | 9.20 |
| August | 0.206626E+10 | 1419.71 | 18-AUG-16:07 | 31.67 | 12.79 | 0.128762E+09 | 70.32 | 31-AUG-20:40 | 23.67 | 11.83 |
| September | 0.155796E+10 | 1214.96 | 09-SEP-15:10 | 29.43 | 13.15 | 0.122382E+09 | 70.33 | 28-SEP-05:40 | 11.80 | 3.99 |
| October | 0.782093E+09 | 830.31 | 11-OCT-16:03 | 23.67 | 8.58 | 0.100624E+09 | 70.33 | 01-OCT-00:20 | 23.67 | 8.58 |
| November | 0.514263E+09 | 589.52 | 10-NOV-19:00 | -2.0 | -2.0 | 80470259.65 | 65.09 | 09-NOV-21:10 | -2.0 | -2.0 |
| December | 0.244615E+09 | 445.39 | 04-DEC-01:00 | 3.00 | 0.63 | 78871415.01 | 50.47 | 04-DEC-21:10 | 7.00 | 0.68 |
| Annual Sum or Average | 0.129192E+11 | 0.121373E+10 | ||||||||
| Minimum of Months | 0.244615E+09 | 445.39 | -2.0 | -4.4 | 71725597.23 | 50.47 | -2.0 | -2.0 | ||
| Maximum of Months | 0.233413E+10 | 1652.23 | 36.60 | 14.84 | 0.128774E+09 | 70.33 | 26.00 | 14.34 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.436923E+09 | 566.21 | 22-JAN-19:50 | -1.7 | -1.7 | 79676478.68 | 51.44 | 20-JAN-22:10 | -1.7 | -1.7 |
| February | 0.307649E+09 | 551.00 | 19-FEB-22:00 | -1.0 | -1.0 | 71737926.10 | 54.32 | 18-FEB-21:10 | -1.0 | -1.0 |
| March | 0.515679E+09 | 647.29 | 16-MAR-17:20 | 15.33 | 5.20 | 89008062.31 | 70.31 | 15-MAR-22:19 | 15.33 | 5.20 |
| April | 0.660576E+09 | 572.26 | 10-APR-24:00 | -2.0 | -4.4 | 87269471.63 | 70.27 | 20-APR-20:40 | 14.33 | 7.97 |
| May | 0.126955E+10 | 1196.13 | 31-MAY-18:00 | 26.00 | 14.34 | 0.121711E+09 | 70.33 | 24-MAY-01:49 | 26.00 | 14.34 |
| June | 0.224384E+10 | 1641.22 | 26-JUN-18:30 | 36.60 | 14.84 | 0.124612E+09 | 70.33 | 09-JUN-03:20 | 36.60 | 14.84 |
| July | 0.234082E+10 | 1549.50 | 15-JUL-18:00 | 33.00 | 13.24 | 0.128774E+09 | 70.33 | 04-JUL-03:00 | 33.00 | 13.24 |
| August | 0.207285E+10 | 1413.89 | 18-AUG-16:07 | 31.67 | 12.79 | 0.128762E+09 | 70.32 | 31-AUG-20:40 | 23.67 | 11.83 |
| September | 0.156255E+10 | 1219.34 | 09-SEP-15:10 | 29.43 | 13.15 | 0.122397E+09 | 70.33 | 15-SEP-03:09 | 10.32 | 4.76 |
| October | 0.782432E+09 | 824.40 | 11-OCT-16:03 | 23.67 | 8.58 | 0.100497E+09 | 70.33 | 07-OCT-21:40 | 23.67 | 8.58 |
| November | 0.512303E+09 | 589.60 | 10-NOV-19:00 | -2.0 | -2.0 | 80461171.17 | 65.11 | 09-NOV-21:10 | -2.0 | -2.0 |
| December | 0.243645E+09 | 445.11 | 04-DEC-01:00 | 3.00 | 0.63 | 78855161.89 | 50.23 | 04-DEC-21:10 | 7.00 | 0.68 |
| Annual Sum or Average | 0.129488E+11 | 0.121376E+10 | ||||||||
| Minimum of Months | 0.243645E+09 | 445.11 | -2.0 | -4.4 | 71737926.10 | 50.23 | -2.0 | -2.0 | ||
| Maximum of Months | 0.234082E+10 | 1641.22 | 36.60 | 14.84 | 0.128774E+09 | 70.33 | 36.60 | 14.84 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.159657E+10 | 1858.99 | 20-JAN-14:00 | 21.00 | 6.96 | 0.102673E+09 | 70.33 | 23-JAN-21:49 | 3.33 | -0.6 |
| February | 0.116557E+10 | 1654.04 | 18-FEB-13:30 | 20.00 | 7.73 | 86673143.22 | 70.32 | 26-FEB-23:00 | 7.00 | 0.37 |
| March | 0.132307E+10 | 2038.94 | 14-MAR-13:00 | 24.00 | 7.90 | 95005841.84 | 70.31 | 11-MAR-01:30 | 24.00 | 7.90 |
| April | 0.977060E+09 | 1236.63 | 21-APR-13:25 | 15.50 | 6.04 | 95875864.99 | 70.33 | 09-APR-19:30 | 15.50 | 6.04 |
| May | 0.153322E+10 | 1376.35 | 16-MAY-13:30 | 27.50 | 12.26 | 0.120506E+09 | 70.33 | 06-MAY-01:39 | 27.50 | 12.26 |
| June | 0.239866E+10 | 1644.06 | 30-JUN-14:00 | 36.10 | 14.44 | 0.120407E+09 | 70.31 | 30-JUN-23:30 | 23.20 | 11.06 |
| July | 0.256544E+10 | 1725.52 | 23-JUL-13:30 | 34.50 | 16.47 | 0.129273E+09 | 70.32 | 15-JUL-22:19 | 34.50 | 16.47 |
| August | 0.268716E+10 | 2021.04 | 31-AUG-13:20 | 30.00 | 11.86 | 0.123962E+09 | 70.32 | 23-AUG-19:40 | 30.00 | 11.86 |
| September | 0.251554E+10 | 2221.17 | 28-SEP-14:10 | 30.32 | 11.26 | 0.123075E+09 | 70.32 | 15-SEP-04:00 | 30.32 | 11.26 |
| October | 0.183535E+10 | 2275.15 | 11-OCT-14:10 | 26.83 | 9.68 | 0.112821E+09 | 70.32 | 09-OCT-02:30 | 26.83 | 9.68 |
| November | 0.154717E+10 | 2040.26 | 07-NOV-13:50 | 21.67 | 7.30 | 0.101887E+09 | 70.32 | 03-NOV-18:30 | 21.67 | 7.30 |
| December | 0.114127E+10 | 1443.69 | 18-DEC-13:30 | 4.00 | -0.4 | 92611022.83 | 70.33 | 16-DEC-17:10 | 4.00 | -0.4 |
| Annual Sum or Average | 0.212861E+11 | 0.130477E+10 | ||||||||
| Minimum of Months | 0.977060E+09 | 1236.63 | 4.00 | -0.4 | 86673143.22 | 70.31 | 3.33 | -0.6 | ||
| Maximum of Months | 0.268716E+10 | 2275.15 | 36.10 | 16.47 | 0.129273E+09 | 70.33 | 34.50 | 16.47 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.159789E+10 | 1862.26 | 20-JAN-14:00 | 21.00 | 6.96 | 0.102642E+09 | 70.32 | 22-JAN-19:00 | -2.0 | -2.0 |
| February | 0.116707E+10 | 1663.03 | 18-FEB-13:30 | 20.00 | 7.73 | 86665478.82 | 70.32 | 26-FEB-23:00 | 7.00 | 0.37 |
| March | 0.132648E+10 | 2046.96 | 14-MAR-13:00 | 24.00 | 7.90 | 95018455.20 | 70.32 | 11-MAR-00:10 | 24.00 | 7.90 |
| April | 0.982588E+09 | 1251.78 | 21-APR-13:25 | 15.50 | 6.04 | 95945036.42 | 70.33 | 07-APR-23:10 | 15.50 | 6.04 |
| May | 0.153917E+10 | 1385.09 | 16-MAY-13:30 | 27.50 | 12.26 | 0.120523E+09 | 70.33 | 18-MAY-23:10 | 5.83 | 3.88 |
| June | 0.240267E+10 | 1650.11 | 30-JUN-14:00 | 36.10 | 14.44 | 0.120407E+09 | 70.31 | 30-JUN-23:30 | 23.20 | 11.06 |
| July | 0.257215E+10 | 1733.74 | 23-JUL-13:30 | 34.50 | 16.47 | 0.129273E+09 | 70.32 | 15-JUL-22:19 | 34.50 | 16.47 |
| August | 0.269352E+10 | 2029.73 | 31-AUG-13:20 | 30.00 | 11.86 | 0.123962E+09 | 70.32 | 23-AUG-19:40 | 30.00 | 11.86 |
| September | 0.251929E+10 | 2226.32 | 28-SEP-13:50 | 30.50 | 11.31 | 0.123078E+09 | 70.32 | 25-SEP-02:09 | 30.50 | 11.31 |
| October | 0.183619E+10 | 2275.59 | 11-OCT-14:10 | 26.83 | 9.68 | 0.112807E+09 | 70.33 | 06-OCT-01:39 | 26.83 | 9.68 |
| November | 0.154712E+10 | 2043.20 | 07-NOV-13:30 | 21.00 | 7.19 | 0.101813E+09 | 70.32 | 14-NOV-19:30 | 2.00 | 1.76 |
| December | 0.114207E+10 | 1452.02 | 18-DEC-13:30 | 4.00 | -0.4 | 92589209.43 | 70.31 | 16-DEC-17:10 | 4.00 | -0.4 |
| Annual Sum or Average | 0.213262E+11 | 0.130472E+10 | ||||||||
| Minimum of Months | 0.982588E+09 | 1251.78 | 4.00 | -0.4 | 86665478.82 | 70.31 | -2.0 | -2.0 | ||
| Maximum of Months | 0.269352E+10 | 2275.59 | 36.10 | 16.47 | 0.129273E+09 | 70.33 | 34.50 | 16.47 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.753014E+09 | 2732.95 | 20-JAN-15:10 | 19.67 | 6.93 | 84194238.40 | 70.36 | 20-JAN-19:40 | 9.33 | 3.26 |
| February | 0.662731E+09 | 2480.52 | 18-FEB-14:30 | 19.50 | 7.87 | 74731190.16 | 70.38 | 17-FEB-19:10 | 19.50 | 7.87 |
| March | 0.960429E+09 | 3220.72 | 13-MAR-15:30 | 23.00 | 6.97 | 85581779.79 | 70.37 | 08-MAR-20:10 | 23.00 | 6.97 |
| April | 0.644682E+09 | 2269.83 | 07-APR-15:30 | 21.00 | 7.93 | 83966901.97 | 70.38 | 19-APR-19:49 | 15.33 | 7.47 |
| May | 0.143870E+10 | 2979.88 | 31-MAY-16:15 | 27.67 | 14.79 | 0.102879E+09 | 70.38 | 27-MAY-19:30 | 27.67 | 14.79 |
| June | 0.327093E+10 | 3936.69 | 26-JUN-17:03 | 37.70 | 15.21 | 0.117504E+09 | 70.39 | 06-JUN-03:30 | 37.70 | 15.21 |
| July | 0.330606E+10 | 3713.29 | 15-JUL-15:30 | 34.50 | 13.50 | 0.126877E+09 | 70.39 | 09-JUL-03:20 | 34.50 | 13.50 |
| August | 0.335778E+10 | 4168.35 | 16-AUG-16:17 | 36.67 | 16.41 | 0.121238E+09 | 70.40 | 02-AUG-01:00 | 36.67 | 16.41 |
| September | 0.265343E+10 | 3809.62 | 28-SEP-15:10 | 29.50 | 11.04 | 0.113793E+09 | 70.39 | 30-SEP-01:30 | 16.90 | 6.80 |
| October | 0.133954E+10 | 3633.91 | 11-OCT-15:10 | 25.67 | 9.32 | 93492921.13 | 70.38 | 04-OCT-18:00 | 25.67 | 9.32 |
| November | 0.907144E+09 | 2977.28 | 05-NOV-15:10 | 20.67 | 6.59 | 83848296.16 | 70.39 | 03-NOV-18:49 | 20.67 | 6.59 |
| December | 0.501702E+09 | 2341.27 | 01-DEC-14:50 | 21.17 | 7.46 | 82451481.58 | 70.28 | 17-DEC-16:19 | 15.00 | 4.44 |
| Annual Sum or Average | 0.197962E+11 | 0.117056E+10 | ||||||||
| Minimum of Months | 0.501702E+09 | 2269.83 | 19.50 | 6.59 | 74731190.16 | 70.28 | 9.33 | 3.26 | ||
| Maximum of Months | 0.335778E+10 | 4168.35 | 37.70 | 16.41 | 0.126877E+09 | 70.40 | 37.70 | 16.41 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 84477633.03 | 448.20 | 21-JAN-19:50 | 3.00 | 2.38 | 78974278.50 | 52.29 | 19-JAN-18:10 | 3.00 | 2.38 |
| February | 96272813.88 | 482.88 | 16-FEB-17:25 | 1.50 | -1.6 | 71504472.34 | 60.80 | 18-FEB-18:10 | 13.33 | 5.19 |
| March | 0.308331E+09 | 1597.04 | 13-MAR-16:30 | 22.50 | 6.82 | 85216177.84 | 70.27 | 14-MAR-20:19 | 15.00 | 4.62 |
| April | 0.314496E+09 | 1355.52 | 20-APR-17:30 | 18.00 | 8.44 | 83739351.96 | 70.39 | 20-APR-21:00 | 14.00 | 7.96 |
| May | 0.117595E+10 | 2770.28 | 31-MAY-17:05 | 26.83 | 14.58 | 0.104679E+09 | 70.40 | 13-MAY-21:10 | 26.83 | 14.58 |
| June | 0.308622E+10 | 3888.75 | 26-JUN-17:12 | 37.70 | 15.21 | 0.122133E+09 | 70.39 | 06-JUN-03:09 | 37.70 | 15.21 |
| July | 0.304794E+10 | 3471.27 | 15-JUL-17:40 | 33.33 | 13.30 | 0.126634E+09 | 70.39 | 03-JUL-23:49 | 33.33 | 13.30 |
| August | 0.269743E+10 | 3666.35 | 16-AUG-16:30 | 36.50 | 16.44 | 0.125694E+09 | 70.40 | 02-AUG-01:49 | 36.50 | 16.44 |
| September | 0.171748E+10 | 2882.94 | 12-SEP-16:30 | 30.25 | 14.03 | 0.112325E+09 | 70.39 | 04-SEP-23:49 | 30.25 | 14.03 |
| October | 0.397214E+09 | 1799.59 | 11-OCT-15:30 | 25.00 | 9.04 | 88174548.12 | 70.39 | 07-OCT-21:10 | 25.00 | 9.04 |
| November | 0.147201E+09 | 678.97 | 07-NOV-15:40 | 21.33 | 7.24 | 77964878.75 | 61.14 | 05-NOV-17:40 | 21.33 | 7.24 |
| December | 46485337.75 | 384.19 | 02-DEC-20:00 | 6.00 | 0.43 | 78662679.48 | 53.91 | 02-DEC-18:10 | 6.00 | 0.43 |
| Annual Sum or Average | 0.131195E+11 | 0.115570E+10 | ||||||||
| Minimum of Months | 46485337.75 | 384.19 | 1.50 | -1.6 | 71504472.34 | 52.29 | 3.00 | 0.43 | ||
| Maximum of Months | 0.308622E+10 | 3888.75 | 37.70 | 16.44 | 0.126634E+09 | 70.40 | 37.70 | 16.44 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.732245E+09 | 2514.92 | 20-JAN-14:00 | 21.00 | 6.96 | 83792345.96 | 70.36 | 21-JAN-17:00 | 7.00 | 3.14 |
| February | 0.651113E+09 | 2328.92 | 18-FEB-13:40 | 20.00 | 7.73 | 74389665.19 | 70.34 | 20-FEB-16:40 | 5.67 | 1.08 |
| March | 0.967813E+09 | 2857.56 | 14-MAR-13:00 | 24.00 | 7.90 | 84823902.11 | 70.39 | 26-MAR-19:10 | 10.67 | 4.15 |
| April | 0.670876E+09 | 2058.63 | 19-APR-13:30 | 22.00 | 8.69 | 83587648.69 | 70.34 | 20-APR-21:00 | 14.00 | 7.96 |
| May | 0.146789E+10 | 2504.27 | 16-MAY-13:30 | 27.50 | 12.26 | 0.103060E+09 | 70.37 | 30-MAY-20:30 | 15.50 | 11.21 |
| June | 0.334642E+10 | 3308.65 | 30-JUN-13:40 | 35.53 | 14.15 | 0.117891E+09 | 70.40 | 06-JUN-02:49 | 35.53 | 14.15 |
| July | 0.347780E+10 | 3356.51 | 23-JUL-13:30 | 34.50 | 16.47 | 0.127204E+09 | 70.40 | 07-JUL-03:30 | 34.50 | 16.47 |
| August | 0.350565E+10 | 3741.23 | 16-AUG-13:00 | 36.00 | 12.83 | 0.121443E+09 | 70.38 | 16-AUG-05:10 | 36.00 | 12.83 |
| September | 0.271377E+10 | 3519.10 | 09-SEP-12:50 | 32.62 | 13.01 | 0.113989E+09 | 70.38 | 17-SEP-08:20 | 16.07 | 9.64 |
| October | 0.129832E+10 | 3151.39 | 11-OCT-13:40 | 26.67 | 9.64 | 93385572.65 | 70.39 | 12-OCT-17:10 | 9.67 | 3.69 |
| November | 0.877288E+09 | 2637.93 | 05-NOV-13:30 | 21.00 | 6.47 | 83445572.02 | 70.38 | 05-NOV-19:00 | 9.00 | 1.77 |
| December | 0.484618E+09 | 1958.94 | 01-DEC-14:00 | 22.00 | 7.94 | 82411074.44 | 70.33 | 03-DEC-17:40 | 9.67 | 3.91 |
| Annual Sum or Average | 0.201938E+11 | 0.116942E+10 | ||||||||
| Minimum of Months | 0.484618E+09 | 1958.94 | 20.00 | 6.47 | 74389665.19 | 70.33 | 5.67 | 1.08 | ||
| Maximum of Months | 0.350565E+10 | 3741.23 | 36.00 | 16.47 | 0.127204E+09 | 70.40 | 36.00 | 16.47 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 64147372.37 | 379.50 | 25-JAN-18:25 | 5.50 | 1.42 | 78555509.97 | 46.41 | 20-JAN-18:10 | 5.50 | 1.42 |
| February | 85305626.12 | 380.63 | 22-FEB-10:30 | 5.50 | 2.17 | 71246624.83 | 56.90 | 18-FEB-18:10 | 5.50 | 2.17 |
| March | 0.272606E+09 | 977.81 | 14-MAR-13:40 | 23.33 | 7.70 | 84784850.62 | 70.32 | 14-MAR-21:10 | 13.00 | 3.83 |
| April | 0.344032E+09 | 1156.40 | 20-APR-13:10 | 21.83 | 9.04 | 83293065.60 | 70.38 | 20-APR-21:40 | 14.00 | 7.96 |
| May | 0.119494E+10 | 1927.29 | 17-MAY-13:40 | 29.00 | 11.73 | 0.104992E+09 | 70.39 | 13-MAY-20:00 | 29.00 | 11.73 |
| June | 0.316868E+10 | 2922.78 | 26-JUN-17:03 | 37.70 | 15.21 | 0.122257E+09 | 70.39 | 01-JUN-00:30 | 37.70 | 15.21 |
| July | 0.322260E+10 | 2954.67 | 16-JUL-14:30 | 35.50 | 14.51 | 0.126791E+09 | 70.40 | 14-JUL-04:00 | 35.50 | 14.51 |
| August | 0.284149E+10 | 2734.49 | 16-AUG-13:00 | 36.00 | 12.83 | 0.125901E+09 | 70.40 | 01-AUG-02:00 | 36.00 | 12.83 |
| September | 0.175341E+10 | 2309.34 | 09-SEP-14:20 | 30.73 | 12.71 | 0.112468E+09 | 70.40 | 05-SEP-22:49 | 30.73 | 12.71 |
| October | 0.358139E+09 | 1175.01 | 11-OCT-14:20 | 26.67 | 9.64 | 87147717.22 | 70.30 | 10-OCT-21:10 | 26.67 | 9.64 |
| November | 0.124265E+09 | 359.96 | 08-NOV-21:00 | 7.00 | 4.42 | 77576107.55 | 57.46 | 06-NOV-18:19 | 7.00 | 4.42 |
| December | 36484753.62 | 373.73 | 02-DEC-20:00 | 6.00 | 0.43 | 78351709.35 | 48.61 | 02-DEC-18:10 | 6.00 | 0.43 |
| Annual Sum or Average | 0.134661E+11 | 0.115336E+10 | ||||||||
| Minimum of Months | 36484753.62 | 359.96 | 5.50 | 0.43 | 71246624.83 | 46.41 | 5.50 | 0.43 | ||
| Maximum of Months | 0.322260E+10 | 2954.67 | 37.70 | 15.21 | 0.126791E+09 | 70.40 | 37.70 | 15.21 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 85781787.88 | 446.22 | 21-JAN-19:50 | 3.00 | 2.38 | 78643271.37 | 47.85 | 20-JAN-18:10 | 3.00 | 2.38 |
| February | 87302413.71 | 424.68 | 27-FEB-20:00 | 4.00 | -0.3 | 71217719.55 | 56.34 | 18-FEB-18:10 | 4.00 | -0.3 |
| March | 0.260930E+09 | 663.50 | 14-MAR-16:12 | 21.67 | 7.01 | 84945661.06 | 70.30 | 14-MAR-20:10 | 15.50 | 4.81 |
| April | 0.319256E+09 | 746.70 | 21-APR-13:30 | 15.50 | 6.04 | 83611396.34 | 70.38 | 27-APR-20:10 | 12.00 | 8.53 |
| May | 0.102777E+10 | 1591.03 | 31-MAY-17:30 | 26.50 | 14.49 | 0.108430E+09 | 70.39 | 14-MAY-20:10 | 26.50 | 14.49 |
| June | 0.245532E+10 | 2381.35 | 26-JUN-17:23 | 37.70 | 15.21 | 0.123430E+09 | 70.39 | 26-JUN-03:00 | 37.70 | 15.21 |
| July | 0.252972E+10 | 2198.63 | 16-JUL-14:40 | 35.67 | 14.60 | 0.127759E+09 | 70.38 | 12-JUL-01:39 | 35.67 | 14.60 |
| August | 0.219240E+10 | 2180.32 | 16-AUG-16:17 | 36.67 | 16.41 | 0.127276E+09 | 70.40 | 02-AUG-04:00 | 36.67 | 16.41 |
| September | 0.141026E+10 | 1732.05 | 09-SEP-15:10 | 29.43 | 13.15 | 0.114908E+09 | 70.40 | 12-SEP-01:49 | 16.70 | 10.03 |
| October | 0.361871E+09 | 928.10 | 11-OCT-15:10 | 25.67 | 9.32 | 88173234.81 | 70.37 | 09-OCT-20:10 | 25.67 | 9.32 |
| November | 0.147455E+09 | 383.66 | 04-NOV-17:12 | 5.43 | 4.62 | 77739865.52 | 57.65 | 06-NOV-18:30 | 14.50 | 4.17 |
| December | 49810835.11 | 392.64 | 01-DEC-21:00 | 5.00 | 0.56 | 78462281.22 | 50.47 | 02-DEC-18:10 | 13.50 | 4.26 |
| Annual Sum or Average | 0.109279E+11 | 0.116460E+10 | ||||||||
| Minimum of Months | 49810835.11 | 383.66 | 3.00 | -0.3 | 71217719.55 | 47.85 | 3.00 | -0.3 | ||
| Maximum of Months | 0.252972E+10 | 2381.35 | 37.70 | 16.41 | 0.127759E+09 | 70.40 | 37.70 | 16.41 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 84701805.84 | 421.13 | 21-JAN-19:40 | 4.00 | 2.69 | 78615668.80 | 47.48 | 20-JAN-18:10 | 4.00 | 2.69 |
| February | 87772153.86 | 424.66 | 27-FEB-20:00 | 4.00 | -0.3 | 71215257.52 | 56.23 | 18-FEB-18:10 | 4.00 | -0.3 |
| March | 0.261737E+09 | 673.37 | 14-MAR-16:07 | 21.83 | 7.03 | 84951387.62 | 70.32 | 14-MAR-20:10 | 15.50 | 4.81 |
| April | 0.323090E+09 | 714.55 | 21-APR-13:30 | 15.50 | 6.04 | 83622586.06 | 70.37 | 27-APR-20:10 | 12.00 | 8.53 |
| May | 0.103561E+10 | 1566.44 | 31-MAY-17:30 | 26.50 | 14.49 | 0.108443E+09 | 70.39 | 29-MAY-20:00 | 26.50 | 14.49 |
| June | 0.246151E+10 | 2357.57 | 26-JUN-17:15 | 37.70 | 15.21 | 0.123419E+09 | 70.39 | 26-JUN-04:40 | 37.70 | 15.21 |
| July | 0.253899E+10 | 2203.09 | 16-JUL-14:40 | 35.67 | 14.60 | 0.127752E+09 | 70.36 | 04-JUL-00:10 | 35.67 | 14.60 |
| August | 0.220153E+10 | 2161.64 | 16-AUG-16:17 | 36.67 | 16.41 | 0.127274E+09 | 70.39 | 02-AUG-04:40 | 36.67 | 16.41 |
| September | 0.141732E+10 | 1737.66 | 09-SEP-14:20 | 30.73 | 12.71 | 0.114899E+09 | 70.40 | 07-SEP-03:00 | 30.73 | 12.71 |
| October | 0.361899E+09 | 923.94 | 11-OCT-15:10 | 25.67 | 9.32 | 88101403.06 | 70.35 | 07-OCT-20:10 | 25.67 | 9.32 |
| November | 0.146550E+09 | 376.39 | 07-NOV-00:20 | 5.67 | 0.80 | 77728125.43 | 57.60 | 06-NOV-18:30 | 5.67 | 0.80 |
| December | 49162285.61 | 384.93 | 02-DEC-20:00 | 6.00 | 0.43 | 78438703.77 | 50.09 | 02-DEC-18:10 | 6.00 | 0.43 |
| Annual Sum or Average | 0.109699E+11 | 0.116446E+10 | ||||||||
| Minimum of Months | 49162285.61 | 376.39 | 4.00 | -0.3 | 71215257.52 | 47.48 | 4.00 | -0.3 | ||
| Maximum of Months | 0.253899E+10 | 2357.57 | 37.70 | 16.41 | 0.127752E+09 | 70.40 | 37.70 | 16.41 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.896892E+09 | 2406.41 | 20-JAN-14:00 | 21.00 | 6.96 | 86389023.60 | 70.39 | 23-JAN-18:00 | 6.00 | 1.47 |
| February | 0.756992E+09 | 2142.05 | 18-FEB-14:00 | 20.00 | 7.73 | 76244776.51 | 70.33 | 18-FEB-10:30 | 20.00 | 7.73 |
| March | 0.948730E+09 | 2555.73 | 15-MAR-13:50 | 20.83 | 6.19 | 87143933.71 | 70.38 | 08-MAR-20:00 | 20.83 | 6.19 |
| April | 0.638066E+09 | 1704.69 | 21-APR-13:30 | 15.50 | 6.04 | 85503198.05 | 70.38 | 20-APR-22:30 | 15.50 | 6.04 |
| May | 0.129464E+10 | 1953.24 | 16-MAY-13:40 | 27.67 | 12.31 | 0.106966E+09 | 70.39 | 23-MAY-21:49 | 13.17 | 10.69 |
| June | 0.263698E+10 | 2572.93 | 30-JUN-14:00 | 36.10 | 14.44 | 0.118927E+09 | 70.38 | 01-JUN-02:09 | 36.10 | 14.44 |
| July | 0.278829E+10 | 2680.24 | 23-JUL-13:30 | 34.50 | 16.47 | 0.128049E+09 | 70.39 | 05-JUL-01:49 | 34.50 | 16.47 |
| August | 0.286120E+10 | 3012.45 | 16-AUG-13:50 | 36.83 | 15.78 | 0.122764E+09 | 70.39 | 12-AUG-05:49 | 36.83 | 15.78 |
| September | 0.236936E+10 | 3039.94 | 28-SEP-13:40 | 30.50 | 11.31 | 0.116702E+09 | 70.39 | 12-SEP-02:20 | 30.50 | 11.31 |
| October | 0.133045E+10 | 2885.75 | 11-OCT-14:10 | 26.83 | 9.68 | 96560073.69 | 70.38 | 16-OCT-18:49 | 6.33 | 0.68 |
| November | 0.102024E+10 | 2472.02 | 05-NOV-13:50 | 21.00 | 6.39 | 86434987.86 | 70.36 | 13-NOV-16:49 | 3.17 | 1.71 |
| December | 0.627116E+09 | 1892.00 | 02-DEC-14:30 | 21.50 | 7.52 | 84038085.12 | 70.35 | 01-DEC-19:19 | 21.50 | 7.52 |
| Annual Sum or Average | 0.181690E+11 | 0.119572E+10 | ||||||||
| Minimum of Months | 0.627116E+09 | 1704.69 | 15.50 | 6.04 | 76244776.51 | 70.33 | 3.17 | 0.68 | ||
| Maximum of Months | 0.286120E+10 | 3039.94 | 36.83 | 16.47 | 0.128049E+09 | 70.39 | 36.83 | 16.47 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.899383E+09 | 2416.01 | 20-JAN-14:00 | 21.00 | 6.96 | 86332209.03 | 70.33 | 23-JAN-18:00 | 6.00 | 1.47 |
| February | 0.761448E+09 | 2156.53 | 18-FEB-13:40 | 20.00 | 7.73 | 76198402.79 | 70.27 | 25-FEB-16:19 | 12.00 | 4.01 |
| March | 0.953703E+09 | 2571.86 | 15-MAR-13:40 | 20.67 | 6.10 | 87069219.56 | 70.39 | 09-MAR-21:19 | 20.67 | 6.10 |
| April | 0.644091E+09 | 1729.04 | 21-APR-13:30 | 15.50 | 6.04 | 85479196.05 | 70.37 | 06-APR-21:10 | 15.50 | 6.04 |
| May | 0.130317E+10 | 1970.00 | 16-MAY-13:40 | 27.67 | 12.31 | 0.106946E+09 | 70.38 | 06-MAY-23:40 | 27.67 | 12.31 |
| June | 0.264375E+10 | 2581.60 | 30-JUN-13:50 | 35.82 | 14.30 | 0.118927E+09 | 70.37 | 23-JUN-01:30 | 35.82 | 14.30 |
| July | 0.279778E+10 | 2691.78 | 23-JUL-13:30 | 34.50 | 16.47 | 0.128050E+09 | 70.40 | 05-JUL-01:49 | 34.50 | 16.47 |
| August | 0.287016E+10 | 3019.91 | 16-AUG-13:50 | 36.83 | 15.78 | 0.122762E+09 | 70.38 | 12-AUG-04:10 | 36.83 | 15.78 |
| September | 0.237616E+10 | 3052.60 | 28-SEP-13:40 | 30.50 | 11.31 | 0.116683E+09 | 70.39 | 17-SEP-00:10 | 30.50 | 11.31 |
| October | 0.133395E+10 | 2886.75 | 11-OCT-14:10 | 26.83 | 9.68 | 96508912.09 | 70.39 | 05-OCT-21:00 | 26.83 | 9.68 |
| November | 0.102268E+10 | 2478.55 | 05-NOV-13:50 | 21.00 | 6.39 | 86369390.71 | 70.37 | 03-NOV-18:00 | 21.00 | 6.39 |
| December | 0.629129E+09 | 1894.76 | 01-DEC-14:00 | 22.00 | 7.94 | 84015382.25 | 70.33 | 01-DEC-19:30 | 9.50 | 2.75 |
| Annual Sum or Average | 0.182354E+11 | 0.119534E+10 | ||||||||
| Minimum of Months | 0.629129E+09 | 1729.04 | 15.50 | 6.04 | 76198402.79 | 70.27 | 6.00 | 1.47 | ||
| Maximum of Months | 0.287016E+10 | 3052.60 | 36.83 | 16.47 | 0.128050E+09 | 70.40 | 36.83 | 16.47 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 | -1.8 | 0.125087E+09 | 109.43 | 20-JAN-21:10 | 7.17 | 1.69 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 | -5.3 | 0.109505E+09 | 118.38 | 18-FEB-21:10 | 10.00 | 3.85 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 | -1.1 | 0.146787E+09 | 143.37 | 14-MAR-20:10 | 15.50 | 4.81 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 | 2.10 | 0.148677E+09 | 145.40 | 20-APR-20:10 | 14.83 | 7.98 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 | 4.75 | 0.216414E+09 | 163.22 | 31-MAY-20:10 | 18.83 | 12.37 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 | 11.26 | 0.269100E+09 | 186.00 | 26-JUN-20:10 | 32.05 | 13.25 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 | 10.91 | 0.279432E+09 | 179.93 | 15-JUL-20:10 | 27.50 | 11.25 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 | 15.43 | 0.275080E+09 | 182.74 | 16-AUG-20:10 | 28.50 | 11.68 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 | 10.64 | 0.240145E+09 | 167.08 | 10-SEP-20:10 | 23.20 | 9.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 | 8.03 | 0.164918E+09 | 143.22 | 10-OCT-20:10 | 14.83 | 4.22 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 | -5.7 | 0.131091E+09 | 121.15 | 05-NOV-20:10 | 8.67 | 1.66 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 | -0.5 | 0.110329E+09 | 105.90 | 02-DEC-21:10 | 6.33 | 1.21 |
| Annual Sum or Average | 0.00 | 0.221656E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -5.7 | -5.7 | 0.109505E+09 | 105.90 | 6.33 | 1.21 | ||
| Maximum of Months | 0.00 | 0.00 | 22.27 | 15.43 | 0.279432E+09 | 186.00 | 32.05 | 13.25 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 | -1.8 | 86855851.30 | 88.52 | 24-JAN-23:10 | 2.83 | 0.23 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 | -5.3 | 69983448.34 | 87.94 | 19-FEB-05:40 | 6.33 | 1.62 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 | -1.1 | 0.104533E+09 | 119.56 | 14-MAR-21:49 | 13.00 | 4.01 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 | 2.10 | 0.104042E+09 | 101.69 | 20-APR-21:49 | 14.00 | 7.96 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 | 4.75 | 0.182384E+09 | 140.74 | 17-MAY-21:49 | 17.83 | 9.07 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 | 11.26 | 0.273170E+09 | 239.45 | 26-JUN-17:10 | 37.70 | 15.21 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 | 10.91 | 0.287961E+09 | 210.51 | 15-JUL-17:10 | 33.83 | 13.38 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 | 15.43 | 0.283511E+09 | 225.50 | 16-AUG-17:10 | 35.67 | 16.25 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 | 10.64 | 0.255660E+09 | 185.27 | 10-SEP-17:10 | 30.32 | 12.14 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 | 8.03 | 0.165312E+09 | 148.94 | 01-OCT-00:10 | 10.30 | 8.03 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 | -5.7 | 0.108884E+09 | 116.70 | 09-NOV-23:19 | 8.00 | 7.05 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 | -0.5 | 80529252.43 | 93.36 | 04-DEC-23:19 | 7.67 | 0.72 |
| Annual Sum or Average | 0.00 | 0.200283E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -5.7 | -5.7 | 69983448.34 | 87.94 | 2.83 | 0.23 | ||
| Maximum of Months | 0.00 | 0.00 | 22.27 | 15.43 | 0.287961E+09 | 239.45 | 37.70 | 16.25 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 | -1.8 | 0.178804E+09 | 121.43 | 21-JAN-21:10 | 2.17 | 2.17 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 | -5.3 | 0.153958E+09 | 122.77 | 18-FEB-21:10 | 10.00 | 3.85 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 | -1.1 | 0.190159E+09 | 149.82 | 15-MAR-20:10 | 10.50 | 2.18 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 | 2.10 | 0.187015E+09 | 140.00 | 20-APR-20:10 | 14.83 | 7.98 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 | 4.75 | 0.253661E+09 | 156.37 | 31-MAY-20:10 | 18.83 | 12.37 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 | 11.26 | 0.275802E+09 | 167.47 | 26-JUN-20:10 | 32.05 | 13.25 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 | 10.91 | 0.285013E+09 | 165.35 | 15-JUL-20:10 | 27.50 | 11.25 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 | 15.43 | 0.283211E+09 | 164.91 | 16-AUG-20:10 | 28.50 | 11.68 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 | 10.64 | 0.264413E+09 | 160.61 | 10-SEP-20:10 | 23.20 | 9.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 | 8.03 | 0.217476E+09 | 151.49 | 11-OCT-20:10 | 10.83 | 5.03 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 | -5.7 | 0.179389E+09 | 134.57 | 09-NOV-21:10 | 8.83 | 7.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 | -0.5 | 0.160960E+09 | 116.03 | 04-DEC-21:10 | 7.00 | 0.68 |
| Annual Sum or Average | 0.00 | 0.262986E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -5.7 | -5.7 | 0.153958E+09 | 116.03 | 2.17 | 0.68 | ||
| Maximum of Months | 0.00 | 0.00 | 22.27 | 15.43 | 0.285013E+09 | 167.47 | 32.05 | 13.25 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.373792E+09 | 1334.22 | 06-JAN-05:00 | -8.0 |
| February | 0.767479E+09 | 1552.09 | 07-FEB-03:00 | -8.0 |
| March | 0.678383E+09 | 1707.74 | 19-MAR-07:50 | -13.3 |
| April | 0.498546E+09 | 1157.20 | 17-APR-05:00 | -8.0 |
| May | 51164620.26 | 590.76 | 02-MAY-06:00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.153850E+09 | 1058.77 | 31-OCT-24:00 | -5.8 |
| November | 0.203304E+09 | 1199.80 | 30-NOV-06:00 | -12.0 |
| December | 0.728168E+09 | 1912.20 | 21-DEC-08:05 | -20.0 |
| Annual Sum or Average | 0.345469E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -20.0 | |
| Maximum of Months | 0.767479E+09 | 1912.20 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.133603E+10 | 1552.76 | 06-JAN-04:50 | -8.7 |
| February | 0.158729E+10 | 1833.93 | 12-FEB-05:40 | -19.3 |
| March | 0.115157E+10 | 1953.96 | 19-MAR-07:45 | -13.3 |
| April | 0.769776E+09 | 1214.98 | 17-APR-05:00 | -8.0 |
| May | 69289327.01 | 656.96 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.255942E+09 | 1111.93 | 31-OCT-24:00 | -5.8 |
| November | 0.561064E+09 | 1413.47 | 30-NOV-06:00 | -12.0 |
| December | 0.161227E+10 | 2137.81 | 23-DEC-08:00 | -22.0 |
| Annual Sum or Average | 0.734323E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.161227E+10 | 2137.81 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141807E+09 | 9183.92 | 09-JAN-08:61 | 5.67 |
| February | 0.351837E+09 | 9085.50 | 07-FEB-08:61 | -2.7 |
| March | 0.265599E+09 | 9209.78 | 06-MAR-08:61 | 3.17 |
| April | 0.230602E+09 | 9141.06 | 25-APR-07:01 | 1.83 |
| May | 0.230910E+09 | 9109.21 | 02-MAY-07:01 | 1.33 |
| June | 0.415616E+09 | 834.81 | 26-JUN-16:01 | 38.62 |
| July | 0.435950E+09 | 677.18 | 14-JUL-16:12 | 32.00 |
| August | 0.337275E+09 | 773.17 | 16-AUG-16:13 | 36.67 |
| September | 0.205212E+09 | 565.08 | 06-SEP-16:13 | 29.93 |
| October | 0.101181E+09 | 8797.73 | 31-OCT-07:01 | -9.0 |
| November | 86334077.41 | 9059.72 | 01-NOV-06:01 | -2.8 |
| December | 0.308596E+09 | 9222.52 | 26-DEC-08:61 | 6.00 |
| Annual Sum or Average | 0.311092E+10 | |||
| Minimum of Months | 86334077.41 | 565.08 | -9.0 | |
| Maximum of Months | 0.435950E+09 | 9222.52 | 38.62 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.134312E+10 | 1590.46 | 06-JAN-04:50 | -8.7 |
| February | 0.158669E+10 | 1889.90 | 12-FEB-05:40 | -19.3 |
| March | 0.110725E+10 | 1941.87 | 19-MAR-07:45 | -13.3 |
| April | 0.725663E+09 | 1192.60 | 04-APR-05:00 | -2.0 |
| May | 62832017.67 | 709.03 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.252387E+09 | 1115.44 | 31-OCT-24:00 | -5.8 |
| November | 0.575069E+09 | 1439.72 | 30-NOV-06:00 | -12.0 |
| December | 0.160655E+10 | 2160.19 | 21-DEC-23:10 | -18.3 |
| Annual Sum or Average | 0.725956E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -19.3 | |
| Maximum of Months | 0.160655E+10 | 2160.19 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.597835E+09 | 896.25 | 06-JAN-04:50 | -8.7 |
| February | 0.806512E+09 | 1071.79 | 12-FEB-08:20 | -16.0 |
| March | 0.489982E+09 | 981.45 | 19-MAR-07:45 | -13.3 |
| April | 0.252490E+09 | 605.09 | 03-APR-07:35 | -5.3 |
| May | 17681440.27 | 284.85 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 70648626.24 | 553.58 | 31-OCT-24:00 | -5.8 |
| November | 0.188987E+09 | 750.70 | 30-NOV-06:00 | -12.0 |
| December | 0.758922E+09 | 1303.35 | 23-DEC-08:00 | -22.0 |
| Annual Sum or Average | 0.318306E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.806512E+09 | 1303.35 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.598461E+09 | 897.71 | 06-JAN-04:50 | -8.7 |
| February | 0.807354E+09 | 1072.33 | 12-FEB-08:20 | -16.0 |
| March | 0.487974E+09 | 979.39 | 19-MAR-07:45 | -13.3 |
| April | 0.250885E+09 | 605.92 | 03-APR-07:35 | -5.3 |
| May | 17387446.46 | 286.75 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 70422562.70 | 553.32 | 31-OCT-24:00 | -5.8 |
| November | 0.189904E+09 | 752.49 | 30-NOV-06:00 | -12.0 |
| December | 0.759241E+09 | 1302.82 | 23-DEC-08:00 | -22.0 |
| Annual Sum or Average | 0.318163E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.807354E+09 | 1302.82 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 70819343.96 | 649.55 | 06-JAN-05:00 | -8.0 |
| February | 0.278574E+09 | 856.05 | 07-FEB-03:00 | -8.0 |
| March | 0.177552E+09 | 717.39 | 19-MAR-07:50 | -13.3 |
| April | 0.121694E+09 | 541.36 | 04-APR-05:00 | -2.0 |
| May | 7861634.49 | 196.70 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 33919713.16 | 487.35 | 31-OCT-24:00 | -5.8 |
| November | 51489256.41 | 579.31 | 01-NOV-02:70 | -4.2 |
| December | 0.216115E+09 | 1020.74 | 21-DEC-08:10 | -20.0 |
| Annual Sum or Average | 0.958024E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -20.0 | |
| Maximum of Months | 0.278574E+09 | 1020.74 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 94031151.60 | 765.25 | 06-JAN-05:00 | -8.0 |
| February | 0.355905E+09 | 994.48 | 07-FEB-03:00 | -8.0 |
| March | 0.229195E+09 | 778.52 | 19-MAR-07:50 | -13.3 |
| April | 0.158281E+09 | 644.72 | 04-APR-05:00 | -2.0 |
| May | 9702280.50 | 219.42 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 40361171.60 | 558.52 | 31-OCT-24:00 | -5.8 |
| November | 62435485.87 | 655.96 | 01-NOV-02:70 | -4.2 |
| December | 0.271311E+09 | 1127.57 | 21-DEC-08:09 | -20.0 |
| Annual Sum or Average | 0.122122E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -20.0 | |
| Maximum of Months | 0.355905E+09 | 1127.57 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.146496E+09 | 1076.88 | 06-JAN-05:00 | -8.0 |
| February | 0.405878E+09 | 1260.89 | 07-FEB-03:00 | -8.0 |
| March | 0.268434E+09 | 1648.23 | 19-MAR-07:00 | -15.6 |
| April | 0.190825E+09 | 876.20 | 17-APR-05:00 | -8.0 |
| May | 3100702.23 | 221.94 | 02-MAY-06:00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.186578E+09 | 1142.85 | 31-OCT-24:00 | -5.8 |
| November | 0.200711E+09 | 1354.29 | 30-NOV-06:00 | -12.0 |
| December | 0.627356E+09 | 1902.70 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.202938E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.627356E+09 | 1902.70 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.588163E+09 | 1251.88 | 06-JAN-05:00 | -8.0 |
| February | 0.806262E+09 | 1578.63 | 12-FEB-05:40 | -19.3 |
| March | 0.471261E+09 | 1726.02 | 19-MAR-07:45 | -13.3 |
| April | 0.258967E+09 | 913.74 | 17-APR-05:00 | -8.0 |
| May | 7059063.41 | 281.45 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.266810E+09 | 1161.03 | 31-OCT-24:00 | -5.8 |
| November | 0.471947E+09 | 1524.00 | 30-NOV-06:00 | -12.0 |
| December | 0.132056E+10 | 2104.31 | 21-DEC-23:10 | -18.3 |
| Annual Sum or Average | 0.419103E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -19.3 | |
| Maximum of Months | 0.132056E+10 | 2104.31 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.150699E+09 | 1120.23 | 06-JAN-05:00 | -8.0 |
| February | 0.422402E+09 | 1262.86 | 07-FEB-03:00 | -8.0 |
| March | 0.261239E+09 | 1635.30 | 19-MAR-07:50 | -13.3 |
| April | 0.180941E+09 | 863.07 | 04-APR-05:00 | -2.0 |
| May | 3310099.27 | 219.22 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.182578E+09 | 1150.59 | 31-OCT-24:00 | -5.8 |
| November | 0.205196E+09 | 1386.29 | 30-NOV-06:00 | -12.0 |
| December | 0.631090E+09 | 1931.29 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.203746E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.631090E+09 | 1931.29 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.579946E+09 | 1295.09 | 06-JAN-05:00 | -8.0 |
| February | 0.817155E+09 | 1646.25 | 12-FEB-05:40 | -19.3 |
| March | 0.432753E+09 | 1715.32 | 19-MAR-07:45 | -13.3 |
| April | 0.251629E+09 | 886.21 | 04-APR-05:00 | -2.0 |
| May | 8480410.21 | 379.10 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.264196E+09 | 1168.80 | 31-OCT-24:00 | -5.8 |
| November | 0.483618E+09 | 1553.58 | 30-NOV-06:00 | -12.0 |
| December | 0.131077E+10 | 2168.60 | 21-DEC-23:10 | -18.3 |
| Annual Sum or Average | 0.414854E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -19.3 | |
| Maximum of Months | 0.131077E+10 | 2168.60 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141470E+09 | 593.45 | 06-JAN-05:00 | -8.0 |
| February | 0.248064E+09 | 777.16 | 12-FEB-05:40 | -19.3 |
| March | 80519522.79 | 734.61 | 19-MAR-07:45 | -13.3 |
| April | 37319880.53 | 312.60 | 17-APR-05:00 | -8.0 |
| May | 156713.47 | 32.00 | 04-MAY-11:00 | 24.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 54435841.52 | 502.37 | 31-OCT-24:00 | -5.8 |
| November | 0.114442E+09 | 727.10 | 30-NOV-06:00 | -12.0 |
| December | 0.480329E+09 | 1107.41 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.115674E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.480329E+09 | 1107.41 | 24.00 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141594E+09 | 595.53 | 06-JAN-05:00 | -8.0 |
| February | 0.249292E+09 | 781.06 | 12-FEB-05:40 | -19.3 |
| March | 79975508.44 | 733.64 | 19-MAR-07:45 | -13.3 |
| April | 36976304.53 | 312.30 | 04-APR-05:00 | -2.0 |
| May | 132709.39 | 30.96 | 04-MAY-11:00 | 24.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 54153424.23 | 502.36 | 31-OCT-24:00 | -5.8 |
| November | 0.114896E+09 | 729.09 | 30-NOV-06:00 | -12.0 |
| December | 0.480620E+09 | 1109.14 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.115764E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.480620E+09 | 1109.14 | 24.00 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 18722733.20 | 384.73 | 06-JAN-05:00 | -8.0 |
| February | 93007681.34 | 571.49 | 07-FEB-03:00 | -8.0 |
| March | 32614325.87 | 675.30 | 19-MAR-07:50 | -13.3 |
| April | 18037319.12 | 290.53 | 04-APR-05:00 | -2.0 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 30443049.80 | 474.86 | 31-OCT-24:00 | -5.8 |
| November | 42940108.40 | 595.46 | 01-NOV-02:70 | -4.2 |
| December | 0.159222E+09 | 908.74 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.394987E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.159222E+09 | 908.74 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 18716259.27 | 386.35 | 06-JAN-05:00 | -8.0 |
| February | 93539084.14 | 571.67 | 07-FEB-03:00 | -8.0 |
| March | 32596455.22 | 674.43 | 19-MAR-07:50 | -13.3 |
| April | 17864769.82 | 291.07 | 04-APR-05:00 | -2.0 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 30327605.01 | 474.79 | 31-OCT-24:00 | -5.8 |
| November | 43111743.83 | 595.39 | 01-NOV-02:70 | -4.2 |
| December | 0.159445E+09 | 910.67 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.395601E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.159445E+09 | 910.67 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.127001E+10 | 2591.79 | 05-JAN-03:00 | -16.0 |
| February | 0.159421E+10 | 3044.13 | 12-FEB-05:40 | -19.3 |
| March | 0.132874E+10 | 3475.08 | 19-MAR-07:00 | -15.6 |
| April | 0.110715E+10 | 2181.82 | 15-APR-05:00 | -5.0 |
| May | 0.107977E+09 | 1145.07 | 02-MAY-06:00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 45148149.51 | 1173.20 | 22-SEP-05:00 | -1.7 |
| October | 0.924116E+09 | 2218.51 | 31-OCT-24:00 | -5.8 |
| November | 0.114136E+10 | 2886.37 | 30-NOV-06:00 | -12.0 |
| December | 0.231287E+10 | 3685.72 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.983157E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.231287E+10 | 3685.72 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.213564E+10 | 2628.50 | 05-JAN-03:00 | -16.0 |
| February | 0.228006E+10 | 3229.48 | 12-FEB-05:40 | -19.3 |
| March | 0.164333E+10 | 3512.67 | 19-MAR-07:05 | -15.2 |
| April | 0.124210E+10 | 2212.80 | 15-APR-05:00 | -5.0 |
| May | 0.119773E+09 | 1217.70 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 62617208.22 | 1237.45 | 22-SEP-05:00 | -1.7 |
| October | 0.114724E+10 | 2233.81 | 31-OCT-24:00 | -5.8 |
| November | 0.174461E+10 | 2950.78 | 30-NOV-06:00 | -12.0 |
| December | 0.328586E+10 | 3763.20 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.136612E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.328586E+10 | 3763.20 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.128092E+10 | 2601.11 | 05-JAN-03:00 | -16.0 |
| February | 0.159453E+10 | 3092.77 | 12-FEB-05:40 | -19.3 |
| March | 0.130372E+10 | 3463.97 | 19-MAR-07:00 | -15.6 |
| April | 0.108263E+10 | 2171.78 | 15-APR-05:00 | -5.0 |
| May | 0.101200E+09 | 1222.22 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 43412648.96 | 1155.01 | 22-SEP-05:00 | -1.7 |
| October | 0.926781E+09 | 2227.18 | 31-OCT-24:00 | -5.8 |
| November | 0.114969E+10 | 2900.84 | 30-NOV-06:00 | -12.0 |
| December | 0.231288E+10 | 3696.97 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.979577E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.231288E+10 | 3696.97 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.212929E+10 | 2638.07 | 05-JAN-03:00 | -16.0 |
| February | 0.226390E+10 | 3274.78 | 12-FEB-05:40 | -19.3 |
| March | 0.158261E+10 | 3500.54 | 19-MAR-07:00 | -15.6 |
| April | 0.121687E+10 | 2201.32 | 15-APR-05:00 | -5.0 |
| May | 0.113325E+09 | 1320.27 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 57849032.20 | 1208.11 | 22-SEP-05:00 | -1.7 |
| October | 0.114095E+10 | 2243.39 | 31-OCT-24:00 | -5.8 |
| November | 0.174759E+10 | 2964.64 | 30-NOV-06:00 | -12.0 |
| December | 0.326964E+10 | 3811.61 | 21-DEC-23:00 | -18.0 |
| Annual Sum or Average | 0.135220E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -19.3 | |
| Maximum of Months | 0.326964E+10 | 3811.61 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.128408E+10 | 1771.31 | 05-JAN-03:00 | -16.0 |
| February | 0.139197E+10 | 2138.41 | 12-FEB-05:40 | -19.3 |
| March | 0.916812E+09 | 2207.94 | 19-MAR-07:45 | -13.3 |
| April | 0.632642E+09 | 1362.80 | 17-APR-05:00 | -8.0 |
| May | 45378466.51 | 721.37 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 22067629.03 | 642.66 | 22-SEP-05:00 | -1.7 |
| October | 0.606549E+09 | 1435.39 | 31-OCT-24:00 | -5.8 |
| November | 0.998123E+09 | 1945.73 | 30-NOV-06:00 | -12.0 |
| December | 0.203275E+10 | 2542.17 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.793037E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.203275E+10 | 2542.17 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.128631E+10 | 1771.52 | 05-JAN-03:00 | -16.0 |
| February | 0.139365E+10 | 2141.55 | 12-FEB-05:40 | -19.3 |
| March | 0.915600E+09 | 2207.59 | 19-MAR-07:45 | -13.3 |
| April | 0.632907E+09 | 1361.42 | 17-APR-05:00 | -8.0 |
| May | 45565634.32 | 731.93 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 21953214.75 | 638.26 | 22-SEP-05:00 | -1.7 |
| October | 0.607892E+09 | 1434.98 | 31-OCT-24:00 | -5.8 |
| November | 0.100067E+10 | 1946.25 | 30-NOV-06:00 | -12.0 |
| December | 0.203394E+10 | 2543.61 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.793849E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.203394E+10 | 2543.61 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.598347E+09 | 1729.59 | 05-JAN-03:00 | -16.0 |
| February | 0.840967E+09 | 1932.28 | 12-FEB-05:40 | -19.3 |
| March | 0.682538E+09 | 2160.98 | 19-MAR-07:00 | -15.6 |
| April | 0.524581E+09 | 1365.54 | 17-APR-05:00 | -8.0 |
| May | 39099166.55 | 618.70 | 02-MAY-05:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 15176757.35 | 573.58 | 22-SEP-05:00 | -1.7 |
| October | 0.457264E+09 | 1419.25 | 31-OCT-24:00 | -5.8 |
| November | 0.548948E+09 | 1874.17 | 30-NOV-06:00 | -12.0 |
| December | 0.121655E+10 | 2456.36 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.492347E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.121655E+10 | 2456.36 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.600755E+09 | 1729.78 | 05-JAN-03:00 | -16.0 |
| February | 0.843566E+09 | 1936.30 | 12-FEB-05:40 | -19.3 |
| March | 0.682778E+09 | 2160.73 | 19-MAR-07:00 | -15.6 |
| April | 0.524211E+09 | 1364.16 | 17-APR-05:00 | -8.0 |
| May | 39368117.99 | 622.98 | 03-MAY-03:00 | 2.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 15091119.08 | 571.55 | 22-SEP-05:00 | -1.7 |
| October | 0.457900E+09 | 1419.53 | 31-OCT-24:00 | -5.8 |
| November | 0.550812E+09 | 1875.90 | 30-NOV-06:00 | -12.0 |
| December | 0.121809E+10 | 2457.87 | 22-DEC-04:00 | -22.0 |
| Annual Sum or Average | 0.493257E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -22.0 | |
| Maximum of Months | 0.121809E+10 | 2457.87 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -5.7 | |
| Maximum of Months | 0.00 | 0.00 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -5.7 | |
| Maximum of Months | 0.00 | 0.00 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 2.77 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -5.7 | |
| Maximum of Months | 0.00 | 0.00 | 22.27 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.229167E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362395E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.395122E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381117E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2177554.16 | 0.183168E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39467167.50 | 63547929.62 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42440605.91 | 58810871.73 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29086999.36 | 63855499.60 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13655158.42 | 0.113661E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 301817.51 | 0.284297E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268138E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.507549E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127129E+09 | 0.291083E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58810871.73 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42440605.91 | 0.507549E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223839E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.355640E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20600.19 | 0.384692E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373349E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2371439.88 | 0.177944E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39467199.40 | 63457912.87 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42440619.38 | 58788867.11 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29087013.23 | 63765201.66 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13655175.39 | 0.111679E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 301820.40 | 0.271380E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.257078E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 968.85 | 0.498910E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127345E+09 | 0.284052E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58788867.11 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42440619.38 | 0.498910E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215394E+09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336004E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372622E+09 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.365109E+09 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1797827.38 | 0.201038E+09 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27802489.74 | 97480653.22 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 23412216.88 | 99832106.79 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19763066.09 | 0.105374E+09 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7842467.16 | 0.157995E+09 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 284201.52 | 0.298115E+09 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263660E+09 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.473158E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 80902268.76 | 0.298578E+10 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97480653.22 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27802489.74 | 0.473158E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223750E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.355580E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11391.95 | 0.384741E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373607E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2259139.15 | 0.179601E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39467244.68 | 63509507.23 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42440663.94 | 58805971.47 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29087042.35 | 63841473.21 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13655194.62 | 0.112100E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 301821.85 | 0.270931E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.257024E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2038.51 | 0.498744E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127225E+09 | 0.284223E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58805971.47 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42440663.94 | 0.498744E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134999E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214476E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20590.68 | 0.231989E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224960E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1434925.93 | 0.110497E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23805658.79 | 38449876.79 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599148.89 | 35531814.32 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17544579.06 | 38532034.49 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8236482.32 | 68036289.45 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182052.56 | 0.165225E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155194E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1294.71 | 0.300907E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 76824732.93 | 0.171880E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35531814.32 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599148.89 | 0.300907E+09 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134998E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214477E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19592.32 | 0.232008E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224986E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1427591.79 | 0.110653E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23805659.22 | 38449879.03 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599149.41 | 35531750.10 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17544579.10 | 38533314.98 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8236482.47 | 68052022.57 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182052.56 | 0.165184E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155195E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1277.19 | 0.300903E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 76816384.05 | 0.171897E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35531750.10 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599149.41 | 0.300903E+09 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140471E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220909E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240447E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231176E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1321003.63 | 0.114209E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23805634.83 | 38506873.41 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599138.05 | 35535503.36 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17544570.51 | 38555482.75 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8236473.23 | 68979205.65 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182050.88 | 0.173723E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.164697E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.309285E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 76688871.14 | 0.177650E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35535503.36 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599138.05 | 0.309285E+09 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140280E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220805E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240468E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231267E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1318272.48 | 0.115003E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23805635.47 | 38544618.11 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599137.74 | 35543996.41 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17544571.16 | 38560537.95 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8236475.21 | 69039294.66 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182051.01 | 0.174038E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.164736E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.309015E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 76686143.07 | 0.177730E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35543996.41 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25599137.74 | 0.309015E+09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341071E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537088E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.583998E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.575163E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3053786.83 | 0.286059E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56494589.72 | 92243608.75 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753372.13 | 85003925.66 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41618751.04 | 92174198.20 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19508570.53 | 0.163294E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 427484.93 | 0.408538E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.390039E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.738673E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181857E+09 | 0.429334E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85003925.66 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753372.13 | 0.738673E+09 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323888E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514385E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.567836E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557177E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3055924.19 | 0.284046E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56494622.33 | 92255036.54 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753382.22 | 85009987.33 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41618760.82 | 92107986.74 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19508599.54 | 0.160552E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 427488.84 | 0.392138E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372578E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.718945E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181859E+09 | 0.416092E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85009987.33 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753382.22 | 0.718945E+09 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341410E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537849E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.586051E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577838E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3053797.54 | 0.286680E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56494676.87 | 92256609.30 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753458.16 | 85007579.54 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41618823.59 | 92194172.02 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19508622.90 | 0.163460E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 427489.49 | 0.408960E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.390056E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.739122E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181857E+09 | 0.430088E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85007579.54 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753458.16 | 0.739122E+09 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323664E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514541E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568775E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560018E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3053808.48 | 0.284694E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56494701.57 | 92259689.37 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753461.12 | 84999641.40 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41618810.20 | 92159536.80 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19508627.62 | 0.161307E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 427491.42 | 0.391720E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372431E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.718610E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181857E+09 | 0.416518E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84999641.40 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60753461.12 | 0.718610E+09 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195608E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.310317E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343059E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338077E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1843409.05 | 0.173298E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34076204.25 | 55666056.98 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644979.83 | 51287300.20 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25103442.21 | 55601312.20 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11767143.97 | 98123915.87 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 257854.23 | 0.239701E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.225636E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.433890E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109693E+09 | 0.252026E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51287300.20 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644979.83 | 0.433890E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195599E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.310347E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343135E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338306E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1843132.90 | 0.173338E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34076205.06 | 55666097.49 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644980.66 | 51287385.70 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25103442.68 | 55601745.35 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11767144.10 | 98148295.84 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 257854.22 | 0.239637E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.225639E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.433878E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109693E+09 | 0.252058E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51287385.70 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644980.66 | 0.433878E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210575E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.329050E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356779E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353212E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1841980.48 | 0.174844E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34076180.82 | 55661018.43 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644971.54 | 51285011.38 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25103430.01 | 55616809.69 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11767126.36 | 99292225.22 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 257852.10 | 0.250473E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239857E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.452287E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109692E+09 | 0.262893E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51285011.38 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644971.54 | 0.452287E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210564E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.329063E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356890E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353354E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1841980.53 | 0.174887E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34076181.86 | 55661059.15 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644972.67 | 51285115.77 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25103430.95 | 55616880.58 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11767127.21 | 99295568.82 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 257852.18 | 0.250477E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239829E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.452284E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109692E+09 | 0.262921E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51285115.77 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36644972.67 | 0.452284E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.443265E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.701008E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761030E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.745701E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3965737.46 | 0.355786E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74143925.41 | 0.119207E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737242.60 | 0.109734E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54572989.36 | 0.119274E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25503207.15 | 0.203091E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 548945.24 | 0.519260E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.505296E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.969359E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238472E+09 | 0.555201E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109734E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737242.60 | 0.969359E+09 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.428998E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.681919E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.746280E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733352E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3965751.01 | 0.353041E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74143923.60 | 0.119711E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737211.69 | 0.110077E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54572947.22 | 0.118673E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25503274.84 | 0.197472E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 548948.72 | 0.505410E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.491731E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.952731E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238472E+09 | 0.543939E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110077E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737211.69 | 0.952731E+09 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.443667E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.701825E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.763310E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.748912E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3965764.88 | 0.358018E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74144131.27 | 0.119939E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737450.11 | 0.110408E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54573141.43 | 0.119809E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25503341.90 | 0.204691E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 548955.45 | 0.520705E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.505788E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.970167E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238473E+09 | 0.556724E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110408E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737450.11 | 0.970167E+09 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.428446E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.681594E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.747764E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.735967E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3965770.21 | 0.355844E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74144122.98 | 0.120118E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737398.82 | 0.110530E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54573064.46 | 0.119267E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25503279.81 | 0.200287E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 548952.88 | 0.505720E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.491383E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.951961E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238473E+09 | 0.544888E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110530E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79737398.82 | 0.951961E+09 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258330E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.410601E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.449327E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.441973E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2392062.61 | 0.216799E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44721853.42 | 73238993.67 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095582.74 | 67422010.45 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32917100.44 | 72847236.86 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15382971.91 | 0.122067E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 331118.53 | 0.304579E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.296297E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.574210E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143841E+09 | 0.328769E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67422010.45 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095582.74 | 0.574210E+09 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258325E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.410639E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.449476E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442205E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2392062.63 | 0.216920E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44721859.34 | 73240535.02 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095586.35 | 67421204.83 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32917105.36 | 72855074.22 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15382972.02 | 0.122147E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 331118.45 | 0.304625E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.296306E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.574189E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143841E+09 | 0.328835E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67421204.83 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095586.35 | 0.574189E+09 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.269291E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.425453E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.462065E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.452687E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2392053.68 | 0.218730E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44721848.08 | 73003137.32 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095598.37 | 67239617.90 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32917113.57 | 73133472.30 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15382971.05 | 0.125655E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 331116.43 | 0.316180E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306916E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.587820E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143841E+09 | 0.337817E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67239617.90 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095598.37 | 0.587820E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.269294E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.425459E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.462174E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.452859E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2392054.13 | 0.218794E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44721852.11 | 73013354.62 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095603.10 | 67246155.14 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32917126.14 | 73139705.51 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15382974.20 | 0.125667E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 331116.72 | 0.316180E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306908E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.587844E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143841E+09 | 0.337858E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67246155.14 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48095603.10 | 0.587844E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74298294.97 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117518E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130183E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130286E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170733.22 | 69200976.40 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6747038.56 | 28369929.20 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6929139.20 | 26921025.26 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4398918.77 | 28127099.10 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1756742.98 | 42652991.01 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7194.81 | 90716628.21 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85222296.74 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160647E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20009767.54 | 0.984144E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26921025.26 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6929139.20 | 0.160647E+09 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.360419E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339711E+10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288376E+10 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255193E+10 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16374076.61 | 0.150380E+10 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243611E+09 | 0.597494E+09 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.229352E+09 | 0.599477E+09 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185445E+09 | 0.769041E+09 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 67497703.67 | 0.109918E+10 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 234399.86 | 0.283788E+10 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324565E+10 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 133123.97 | 0.404966E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.742647E+09 | 0.271392E+11 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.597494E+09 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243611E+09 | 0.404966E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61215060.79 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95691922.72 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107180E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107056E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164645.16 | 57418410.15 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5892458.81 | 22336183.14 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6174927.80 | 21185107.01 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4014478.43 | 22221831.37 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1545066.28 | 35537681.85 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6476.31 | 76176447.68 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70271993.49 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131559E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17798052.80 | 0.807850E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21185107.01 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6174927.80 | 0.131559E+09 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 307.82 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 468.62 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 796.34 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 538.30 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.89 | 17-MAY-14:50 | 306.51 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 14-JUN-12:00 | 151.12 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.04 | 16-JUL-12:00 | 148.33 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 162.50 | 02-AUG-16:00 | 148.47 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 117.79 | 09-SEP-15:00 | 315.26 | 21-SEP-14:40 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.00 | 11-OCT-14:00 | 432.69 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 477.99 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 692.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.33 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 796.34 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 307.82 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 468.62 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.05 | 14-MAR-13:00 | 796.34 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 538.30 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.89 | 17-MAY-14:50 | 306.51 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 14-JUN-12:00 | 151.12 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.04 | 16-JUL-12:00 | 147.95 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 162.50 | 02-AUG-16:00 | 148.47 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 117.79 | 09-SEP-15:00 | 307.60 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.00 | 11-OCT-14:00 | 432.69 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 477.99 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.04 | 01-DEC-14:00 | 692.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.95 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 796.34 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 270.92 | 07-JAN-12:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 418.55 | 11-FEB-15:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 677.01 | 19-MAR-06:55 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 534.11 | 14-APR-07:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.89 | 17-MAY-14:50 | 319.43 | 26-MAY-11:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 14-JUN-12:00 | 186.84 | 08-JUN-23:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.89 | 18-JUL-13:00 | 179.68 | 03-JUL-03:00 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 162.50 | 02-AUG-16:00 | 267.02 | 27-AUG-18:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.24 | 13-SEP-14:00 | 319.94 | 21-SEP-15:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.00 | 11-OCT-14:00 | 414.61 | 29-OCT-09:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 477.99 | 01-NOV-10:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 600.25 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 179.68 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 677.01 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 307.82 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 468.62 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.14 | 14-MAR-13:00 | 796.34 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 538.30 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.89 | 17-MAY-14:50 | 306.51 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 14-JUN-12:00 | 151.12 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.04 | 16-JUL-12:00 | 146.99 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 162.50 | 02-AUG-16:00 | 148.47 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 117.79 | 09-SEP-15:00 | 308.80 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.00 | 11-OCT-14:00 | 432.69 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 477.99 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.58 | 01-DEC-14:00 | 692.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.99 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 170.82 | 796.34 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 185.67 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 282.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.84 | 14-MAR-13:00 | 480.33 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 324.69 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.30 | 17-MAY-14:50 | 184.88 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 14-JUN-12:00 | 91.15 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.30 | 16-JUL-12:00 | 89.73 | 03-JUL-03:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 98.02 | 02-AUG-16:00 | 89.55 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.05 | 09-SEP-15:00 | 188.39 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.47 | 11-OCT-14:00 | 260.99 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 288.31 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.98 | 01-DEC-14:00 | 417.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.55 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 480.33 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 185.67 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 282.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.76 | 14-MAR-13:00 | 480.33 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 324.69 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.30 | 17-MAY-14:50 | 184.88 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 14-JUN-12:00 | 91.15 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.30 | 16-JUL-12:00 | 89.72 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 98.02 | 02-AUG-16:00 | 89.55 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.05 | 09-SEP-15:00 | 188.43 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.47 | 11-OCT-14:00 | 260.99 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 288.31 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.97 | 01-DEC-14:00 | 417.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.55 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 480.33 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 185.67 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 282.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 480.33 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 324.69 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.30 | 17-MAY-14:50 | 184.88 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 14-JUN-12:00 | 91.15 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.30 | 16-JUL-12:00 | 89.73 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 98.02 | 02-AUG-16:00 | 89.55 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.05 | 09-SEP-15:00 | 192.77 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.47 | 11-OCT-14:00 | 260.99 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 288.31 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 417.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.55 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 480.33 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 185.67 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 282.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 480.33 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 324.69 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.30 | 17-MAY-14:50 | 184.88 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 14-JUN-12:00 | 91.15 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.30 | 16-JUL-12:00 | 89.73 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 98.02 | 02-AUG-16:00 | 89.55 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.05 | 09-SEP-15:00 | 193.03 | 21-SEP-15:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.47 | 11-OCT-14:00 | 260.99 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 288.31 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 417.99 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.55 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 103.03 | 480.33 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 447.98 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 688.27 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1145.02 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 782.07 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.12 | 17-MAY-14:50 | 452.31 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 14-JUN-12:00 | 217.65 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 212.40 | 16-JUL-12:00 | 214.10 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.86 | 02-AUG-16:00 | 214.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.71 | 09-SEP-15:00 | 451.23 | 21-SEP-14:40 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.26 | 11-OCT-14:00 | 622.27 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 687.53 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 996.37 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.10 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 1145.02 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 442.73 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 673.91 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1145.02 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 774.39 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.12 | 17-MAY-14:50 | 445.55 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 14-JUN-12:00 | 217.65 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 212.40 | 16-JUL-12:00 | 214.10 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.86 | 02-AUG-16:00 | 214.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.71 | 09-SEP-15:00 | 441.13 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.26 | 11-OCT-14:00 | 622.27 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 687.53 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 996.37 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.10 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 1145.02 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 454.64 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 676.24 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1145.02 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 802.31 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.12 | 17-MAY-14:50 | 459.62 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 14-JUN-12:00 | 217.65 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 212.40 | 16-JUL-12:00 | 213.85 | 03-JUL-03:30 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.86 | 02-AUG-16:00 | 214.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.71 | 09-SEP-15:00 | 453.03 | 21-SEP-14:40 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.26 | 11-OCT-14:00 | 622.27 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 687.53 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 996.37 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.85 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 1145.02 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 442.73 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 673.91 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1145.02 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 777.91 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.12 | 17-MAY-14:50 | 457.84 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 14-JUN-12:00 | 217.65 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 212.40 | 16-JUL-12:00 | 213.52 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.86 | 02-AUG-16:00 | 214.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.71 | 09-SEP-15:00 | 443.56 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.26 | 11-OCT-14:00 | 622.27 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 687.53 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 996.37 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.52 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 1145.02 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 267.04 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 406.48 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 690.65 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 475.29 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 17-MAY-14:50 | 275.55 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 14-JUN-12:00 | 131.28 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.11 | 16-JUL-12:00 | 129.14 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.46 | 02-AUG-16:00 | 129.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.76 | 09-SEP-15:00 | 271.27 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.66 | 11-OCT-14:00 | 375.33 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 414.70 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 600.98 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.14 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 690.65 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 267.04 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 406.48 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 690.65 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 476.85 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 17-MAY-14:50 | 275.79 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 14-JUN-12:00 | 131.28 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.11 | 16-JUL-12:00 | 129.14 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.46 | 02-AUG-16:00 | 129.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.76 | 09-SEP-15:00 | 271.37 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.66 | 11-OCT-14:00 | 375.33 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 414.70 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 600.98 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.14 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 690.65 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 281.41 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 422.67 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 690.65 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 496.68 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 17-MAY-14:50 | 277.23 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 14-JUN-12:00 | 131.28 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.11 | 16-JUL-12:00 | 129.14 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.46 | 02-AUG-16:00 | 129.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.76 | 09-SEP-15:00 | 276.87 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.66 | 11-OCT-14:00 | 378.49 | 29-OCT-09:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 414.70 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 600.98 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.14 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 690.65 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 281.58 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 422.57 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 690.65 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 497.44 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 17-MAY-14:50 | 277.23 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 14-JUN-12:00 | 131.28 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.11 | 16-JUL-12:00 | 129.14 | 03-JUL-04:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.46 | 02-AUG-16:00 | 129.21 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.76 | 09-SEP-15:00 | 276.92 | 21-SEP-14:50 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.66 | 11-OCT-14:00 | 378.65 | 29-OCT-09:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 414.70 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 600.98 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.14 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 147.80 | 690.65 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 586.61 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 895.98 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1516.29 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1026.48 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.87 | 17-MAY-14:50 | 584.31 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 322.95 | 14-JUN-12:00 | 289.17 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 280.02 | 16-JUL-12:00 | 260.90 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.28 | 02-AUG-16:00 | 285.59 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.69 | 09-SEP-15:00 | 566.43 | 21-SEP-14:30 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 11-OCT-14:00 | 824.34 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 911.10 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1319.28 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 260.90 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 322.95 | 1516.29 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 586.61 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 892.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1516.29 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1026.48 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.87 | 17-MAY-14:50 | 584.31 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 322.95 | 14-JUN-12:00 | 289.17 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 280.02 | 16-JUL-12:00 | 260.72 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.28 | 02-AUG-16:00 | 285.59 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.69 | 09-SEP-15:00 | 537.62 | 21-SEP-14:40 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 11-OCT-14:00 | 824.34 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 911.10 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1319.28 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 260.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 322.95 | 1516.29 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 597.42 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 892.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1516.29 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1026.48 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.88 | 17-MAY-14:50 | 587.93 | 26-MAY-11:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 322.96 | 14-JUN-12:00 | 289.12 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 280.02 | 16-JUL-12:00 | 257.77 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.28 | 02-AUG-16:00 | 285.27 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.69 | 09-SEP-15:00 | 571.37 | 21-SEP-14:20 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 11-OCT-14:00 | 824.34 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 911.10 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1319.28 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 257.77 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 322.96 | 1516.29 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 586.61 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 892.66 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1516.29 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1026.48 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.88 | 17-MAY-14:50 | 584.31 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 322.96 | 14-JUN-12:00 | 289.34 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 280.02 | 16-JUL-12:00 | 257.51 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.28 | 02-AUG-16:00 | 285.59 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.69 | 09-SEP-15:00 | 546.91 | 21-SEP-14:30 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.71 | 11-OCT-14:00 | 824.34 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 911.10 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1319.28 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 257.51 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 322.96 | 1516.29 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 353.83 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 538.43 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 914.59 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 619.15 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.43 | 17-MAY-14:50 | 352.44 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 14-JUN-12:00 | 174.42 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.90 | 16-JUL-12:00 | 162.24 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.74 | 02-AUG-16:00 | 172.26 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.72 | 09-SEP-15:00 | 337.83 | 21-SEP-14:40 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.97 | 11-OCT-14:00 | 497.22 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 549.55 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 795.76 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 914.59 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 353.83 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 538.43 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 914.59 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 619.15 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.43 | 17-MAY-14:50 | 352.44 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 14-JUN-12:00 | 174.42 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.90 | 16-JUL-12:00 | 162.07 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.74 | 02-AUG-16:00 | 172.26 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.72 | 09-SEP-15:00 | 338.62 | 21-SEP-14:40 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.97 | 11-OCT-14:00 | 497.22 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 549.55 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 795.76 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.07 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 914.59 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 369.54 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 549.62 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 914.59 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 619.15 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.43 | 17-MAY-14:50 | 352.44 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 14-JUN-12:00 | 174.42 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.90 | 16-JUL-12:00 | 162.39 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.74 | 02-AUG-16:00 | 172.26 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.72 | 09-SEP-15:00 | 354.19 | 21-SEP-14:30 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.97 | 11-OCT-14:00 | 497.22 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 549.55 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 795.76 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.39 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 914.59 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 370.10 | 07-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 549.41 | 11-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 914.59 | 19-MAR-07:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 619.15 | 14-APR-07:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.43 | 17-MAY-14:50 | 352.44 | 02-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 14-JUN-12:00 | 174.42 | 08-JUN-23:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.90 | 16-JUL-12:00 | 162.22 | 03-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.74 | 02-AUG-16:00 | 172.26 | 27-AUG-18:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.72 | 09-SEP-15:00 | 354.45 | 21-SEP-14:30 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.97 | 11-OCT-14:00 | 497.22 | 29-OCT-19:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 549.55 | 01-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 795.76 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.22 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 194.80 | 914.59 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 98.67 | 07-JAN-12:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 153.02 | 11-FEB-15:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 244.50 | 19-MAR-06:55 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 181.64 | 14-APR-07:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.86 | 17-MAY-13:00 | 103.93 | 26-MAY-11:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.54 | 14-JUN-12:00 | 59.09 | 08-JUN-23:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.60 | 16-JUL-12:00 | 52.26 | 03-JUL-03:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.33 | 02-AUG-15:00 | 67.70 | 27-AUG-18:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.63 | 09-SEP-15:00 | 107.34 | 21-SEP-14:40 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.20 | 11-OCT-14:00 | 137.53 | 29-OCT-09:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 146.61 | 01-NOV-10:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 212.30 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.26 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.54 | 244.50 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 17724.56 | 05-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 19278.53 | 12-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 16587.89 | 19-MAR-06:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 13109.15 | 17-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1078.67 | 31-MAY-16:03 | 9581.63 | 02-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4685.58 | 26-JUN-16:01 | 7387.85 | 09-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2751.50 | 15-JUL-16:02 | 6783.41 | 03-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3965.94 | 16-AUG-16:01 | 6664.02 | 13-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1831.26 | 10-SEP-16:03 | 11993.12 | 22-SEP-06:01 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.16 | 11-OCT-14:00 | 14780.87 | 30-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 14889.89 | 29-NOV-17:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.46 | 01-DEC-14:00 | 20304.77 | 23-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6664.02 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 4685.58 | 20304.77 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 79.65 | 07-JAN-12:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 121.75 | 11-FEB-15:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 200.84 | 19-MAR-06:55 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 153.59 | 14-APR-07:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.46 | 17-MAY-13:00 | 87.14 | 26-MAY-11:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.31 | 14-JUN-12:00 | 46.13 | 08-JUN-23:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.25 | 16-JUL-12:00 | 42.34 | 03-JUL-03:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.24 | 02-AUG-15:00 | 51.57 | 27-AUG-18:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.54 | 09-SEP-15:00 | 85.31 | 21-SEP-14:40 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.88 | 11-OCT-14:00 | 114.40 | 29-OCT-09:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 119.36 | 01-NOV-10:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 170.77 | 21-DEC-19:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.34 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.31 | 200.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 712.40 | 14-JAN-16:45 | 475.00 | 121.52 | 941.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 233.61 |
| February | 550.30 | 16-FEB-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.00 |
| March | 1240.70 | 13-MAR-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.41 |
| April | 500.06 | 10-APR-21:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 177.23 |
| May | 910.74 | 31-MAY-17:10 | 475.00 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 24.97 | 0.00 |
| June | 2102.55 | 26-JUN-17:20 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 94.27 | 0.00 |
| July | 1956.81 | 15-JUL-17:30 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 92.71 | 0.00 |
| August | 2334.03 | 16-AUG-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.51 | 0.00 |
| September | 2299.81 | 28-SEP-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 24.78 | 0.00 |
| October | 2296.12 | 11-OCT-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 12.82 | 0.00 |
| November | 1496.82 | 07-NOV-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.33 |
| December | 742.78 | 18-DEC-18:11 | 1900.00 | 937.46 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 466.86 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 500.06 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2334.03 | 1900.00 | 937.46 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 94.27 | 466.86 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 342.00 | 21-JAN-17:01 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.17 |
| February | 283.75 | 25-FEB-17:35 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.04 |
| March | 343.65 | 12-MAR-21:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.09 |
| April | 392.30 | 10-APR-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.18 |
| May | 790.35 | 31-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 21.31 | 0.00 |
| June | 2063.49 | 26-JUN-17:23 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 88.09 | 0.00 |
| July | 1876.92 | 15-JUL-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.37 | 0.00 |
| August | 1982.04 | 16-AUG-17:10 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 69.83 | 0.00 |
| September | 1735.02 | 10-SEP-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 32.58 | 0.00 |
| October | 1037.88 | 11-OCT-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.94 |
| November | 411.67 | 18-NOV-17:17 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 102.69 |
| December | 324.13 | 02-DEC-19:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.63 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 283.75 | 123.50 | 86.80 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2063.49 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 95.37 | 102.69 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1003.67 | 05-JAN-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.75 |
| February | 755.05 | 02-FEB-07:02 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.23 |
| March | 4649.88 | 15-MAR-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.82 |
| April | 750.08 | 21-APR-13:00 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.79 |
| May | 5442.86 | 17-MAY-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.42 |
| June | 6504.64 | 19-JUN-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.77 |
| July | 6749.01 | 03-JUL-07:01 | 3609.64 | 4663.33 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.85 |
| August | 6630.50 | 15-AUG-07:01 | 3158.44 | 4080.41 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.97 |
| September | 6671.25 | 05-SEP-07:01 | 3158.44 | 4080.41 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.20 |
| October | 6244.70 | 10-OCT-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.99 |
| November | 5418.61 | 07-NOV-09:02 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.59 |
| December | 1106.14 | 22-DEC-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 220.40 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 750.08 | 0.00 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.42 | |
| Maximum of Months | 6749.01 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 220.40 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 253.45 | 20-JAN-17:25 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.88 |
| February | 248.67 | 18-FEB-18:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.63 |
| March | 341.24 | 16-MAR-06:09 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.64 |
| April | 377.99 | 21-APR-06:03 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.42 |
| May | 630.55 | 17-MAY-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 13.96 | 0.00 |
| June | 1646.69 | 26-JUN-17:27 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 88.09 | 0.00 |
| July | 1634.42 | 16-JUL-14:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 127.08 | 0.00 |
| August | 1547.17 | 16-AUG-17:06 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 69.83 | 0.00 |
| September | 1489.24 | 09-SEP-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 99.44 | 0.00 |
| October | 745.91 | 11-OCT-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.94 |
| November | 395.42 | 10-NOV-06:30 | 237.50 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 193.30 |
| December | 307.99 | 04-DEC-18:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.46 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 248.67 | 59.38 | 30.38 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1646.69 | 2018.75 | 585.91 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 127.08 | 193.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 339.94 | 25-JAN-17:45 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.82 |
| February | 268.56 | 18-FEB-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.58 |
| March | 370.98 | 17-MAR-06:10 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.94 |
| April | 378.02 | 21-APR-06:03 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.31 |
| May | 503.87 | 12-MAY-03:00 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.88 |
| June | 1326.09 | 26-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 41.95 | 0.00 |
| July | 1248.56 | 15-JUL-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 58.23 | 0.00 |
| August | 1217.42 | 16-AUG-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 37.91 | 0.00 |
| September | 1125.93 | 10-SEP-17:15 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 21.59 | 0.00 |
| October | 625.96 | 11-OCT-16:02 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.77 |
| November | 523.25 | 10-NOV-17:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.03 |
| December | 347.20 | 02-DEC-19:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.95 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 268.56 | 206.62 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1326.09 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 58.23 | 122.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 339.70 | 25-JAN-17:45 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.80 |
| February | 268.52 | 18-FEB-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.58 |
| March | 371.25 | 17-MAR-06:10 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.00 |
| April | 378.03 | 21-APR-06:03 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.32 |
| May | 512.18 | 17-MAY-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 8.42 | 0.00 |
| June | 1318.26 | 26-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 41.95 | 0.00 |
| July | 1249.75 | 16-JUL-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 0.00 |
| August | 1207.69 | 16-AUG-17:15 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 39.99 | 0.00 |
| September | 1119.54 | 10-SEP-17:15 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 21.59 | 0.00 |
| October | 621.70 | 11-OCT-16:02 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.77 |
| November | 523.25 | 10-NOV-17:06 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.54 |
| December | 346.91 | 02-DEC-19:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.92 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 268.52 | 206.62 | 117.18 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1318.26 | 2018.75 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 130.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 757.68 | 14-JAN-18:00 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.03 |
| February | 618.80 | 12-FEB-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.58 |
| March | 1118.46 | 15-MAR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.01 |
| April | 538.20 | 10-APR-23:20 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.39 |
| May | 699.61 | 18-MAY-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.89 |
| June | 1360.15 | 26-JUN-17:05 | 1425.00 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 60.59 | 0.00 |
| July | 1358.23 | 23-JUL-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 43.15 | 0.00 |
| August | 1612.82 | 31-AUG-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 16.64 | 0.00 |
| September | 1829.82 | 28-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 28.15 | 0.00 |
| October | 1864.44 | 11-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 14.22 | 0.00 |
| November | 1346.30 | 07-NOV-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.82 |
| December | 882.25 | 18-DEC-23:10 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 255.03 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 538.20 | 0.00 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1864.44 | 1425.00 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 60.59 | 255.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 754.86 | 14-JAN-18:00 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.90 |
| February | 612.56 | 28-FEB-06:10 | 1425.00 | 364.55 | 1907.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.30 |
| March | 1170.17 | 15-MAR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.01 |
| April | 545.79 | 10-APR-23:30 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.10 |
| May | 760.92 | 18-MAY-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.89 |
| June | 1447.71 | 26-JUN-17:17 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 56.86 | 0.00 |
| July | 1503.54 | 23-JUL-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 43.15 | 0.00 |
| August | 1676.59 | 31-AUG-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 16.64 | 0.00 |
| September | 1890.04 | 28-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 28.15 | 0.00 |
| October | 1929.70 | 11-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 14.22 | 0.00 |
| November | 1359.21 | 07-NOV-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.82 |
| December | 879.13 | 18-DEC-23:00 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 261.71 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 545.79 | 0.00 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1929.70 | 1425.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 56.86 | 261.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1943.93 | 20-JAN-15:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.90 |
| February | 1713.78 | 18-FEB-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.60 |
| March | 2617.41 | 13-MAR-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.38 |
| April | 1776.74 | 08-APR-17:13 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.74 |
| May | 2144.58 | 31-MAY-16:25 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 42.55 | 0.00 |
| June | 2798.21 | 26-JUN-17:03 | 1425.00 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 144.15 | 0.00 |
| July | 2647.97 | 15-JUL-17:30 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 132.96 | 0.00 |
| August | 2936.97 | 16-AUG-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 86.81 | 0.00 |
| September | 2892.28 | 28-SEP-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 34.89 | 0.00 |
| October | 2902.46 | 11-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 23.15 | 0.00 |
| November | 2330.47 | 07-NOV-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.43 |
| December | 1500.68 | 02-DEC-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.56 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1500.68 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2936.97 | 1425.00 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 144.15 | 99.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 531.58 | 22-JAN-19:10 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.94 |
| February | 487.39 | 20-FEB-18:35 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 158.17 |
| March | 1089.68 | 15-MAR-16:02 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.26 |
| April | 728.49 | 20-APR-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.24 |
| May | 2049.57 | 31-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.39 | 0.00 |
| June | 2772.72 | 26-JUN-17:27 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 126.41 | 0.00 |
| July | 2564.18 | 15-JUL-17:40 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 134.93 | 0.00 |
| August | 2519.70 | 16-AUG-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 93.20 | 0.00 |
| September | 2109.92 | 12-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 75.22 | 0.00 |
| October | 1440.90 | 11-OCT-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.48 |
| November | 459.79 | 18-NOV-19:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.64 |
| December | 395.16 | 02-DEC-23:00 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.94 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 395.16 | 123.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2772.72 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 134.93 | 198.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1765.01 | 20-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.59 |
| February | 1653.18 | 18-FEB-13:30 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.34 |
| March | 2322.63 | 14-MAR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 |
| April | 1536.64 | 21-APR-12:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.87 |
| May | 1809.75 | 16-MAY-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 39.83 | 0.00 |
| June | 2278.64 | 30-JUN-14:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 228.15 | 0.00 |
| July | 2321.17 | 18-JUL-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 207.84 | 0.00 |
| August | 2560.51 | 31-AUG-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 68.99 | 0.00 |
| September | 2616.98 | 28-SEP-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 49.63 | 0.00 |
| October | 2524.46 | 11-OCT-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 26.99 | 0.00 |
| November | 2063.33 | 07-NOV-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 |
| December | 1174.11 | 02-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.58 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1174.11 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2616.98 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 228.15 | 42.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 483.28 | 21-JAN-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.29 |
| February | 500.64 | 28-FEB-08:25 | 185.25 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.31 |
| March | 894.14 | 15-MAR-10:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.37 |
| April | 761.61 | 21-APR-09:40 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.04 |
| May | 1479.56 | 16-MAY-16:17 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 35.89 | 0.00 |
| June | 2108.32 | 26-JUN-17:30 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 126.41 | 0.00 |
| July | 2133.67 | 16-JUL-14:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 0.00 |
| August | 1870.65 | 16-AUG-17:08 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 100.18 | 0.00 |
| September | 1680.14 | 09-SEP-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 142.39 | 0.00 |
| October | 968.84 | 11-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 23.15 | 0.00 |
| November | 442.57 | 10-NOV-12:50 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 326.50 |
| December | 381.20 | 02-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.74 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 381.20 | 59.38 | 17.36 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2133.67 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 326.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 574.47 | 22-JAN-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.84 |
| February | 550.70 | 19-FEB-22:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.91 |
| March | 646.57 | 16-MAR-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.53 |
| April | 572.53 | 10-APR-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 177.04 |
| May | 1207.49 | 31-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 13.89 | 0.00 |
| June | 1652.23 | 26-JUN-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 70.32 | 0.00 |
| July | 1558.60 | 15-JUL-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 83.50 | 0.00 |
| August | 1419.71 | 18-AUG-16:07 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 109.72 | 0.00 |
| September | 1214.96 | 09-SEP-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 85.88 | 0.00 |
| October | 830.31 | 11-OCT-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.70 |
| November | 589.52 | 10-NOV-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.27 |
| December | 445.39 | 04-DEC-01:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.07 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 445.39 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1652.23 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 109.72 | 177.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 566.21 | 22-JAN-19:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.81 |
| February | 551.00 | 19-FEB-22:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.94 |
| March | 647.29 | 16-MAR-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.53 |
| April | 572.26 | 10-APR-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.95 |
| May | 1196.13 | 31-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 13.89 | 0.00 |
| June | 1641.22 | 26-JUN-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 70.32 | 0.00 |
| July | 1549.50 | 15-JUL-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 83.50 | 0.00 |
| August | 1413.89 | 18-AUG-16:07 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 109.72 | 0.00 |
| September | 1219.34 | 09-SEP-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 85.88 | 0.00 |
| October | 824.40 | 11-OCT-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.70 |
| November | 589.60 | 10-NOV-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.29 |
| December | 445.11 | 04-DEC-01:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 445.11 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1641.22 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 109.72 | 176.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1858.99 | 20-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.99 |
| February | 1654.04 | 18-FEB-13:30 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.54 |
| March | 2038.94 | 14-MAR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| April | 1236.63 | 21-APR-13:25 | 0.00 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.97 |
| May | 1376.35 | 16-MAY-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 24.34 | 0.00 |
| June | 1644.06 | 30-JUN-14:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 137.61 | 0.00 |
| July | 1725.52 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 52.25 | 0.00 |
| August | 2021.04 | 31-AUG-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.58 | 0.00 |
| September | 2221.17 | 28-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 40.33 | 0.00 |
| October | 2275.15 | 11-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 20.30 | 0.00 |
| November | 2040.26 | 07-NOV-13:50 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.35 |
| December | 1443.69 | 18-DEC-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.22 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1236.63 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2275.15 | 118.75 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 137.61 | 166.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1862.26 | 20-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.99 |
| February | 1663.03 | 18-FEB-13:30 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.54 |
| March | 2046.96 | 14-MAR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| April | 1251.78 | 21-APR-13:25 | 0.00 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.97 |
| May | 1385.09 | 16-MAY-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 24.34 | 0.00 |
| June | 1650.11 | 30-JUN-14:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 137.61 | 0.00 |
| July | 1733.74 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 52.25 | 0.00 |
| August | 2029.73 | 31-AUG-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.58 | 0.00 |
| September | 2226.32 | 28-SEP-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 37.42 | 0.00 |
| October | 2275.59 | 11-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 20.30 | 0.00 |
| November | 2043.20 | 07-NOV-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.12 |
| December | 1452.02 | 18-DEC-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.22 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1251.78 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2275.59 | 118.75 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 137.61 | 166.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2732.95 | 20-JAN-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.06 |
| February | 2480.52 | 18-FEB-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.52 |
| March | 3220.72 | 13-MAR-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.25 |
| April | 2269.83 | 07-APR-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.30 |
| May | 2979.88 | 31-MAY-16:15 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 57.31 | 0.00 |
| June | 3936.69 | 26-JUN-17:03 | 1425.00 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 190.12 | 0.00 |
| July | 3713.29 | 15-JUL-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 229.20 | 0.00 |
| August | 4168.35 | 16-AUG-16:17 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 105.79 | 0.00 |
| September | 3809.62 | 28-SEP-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 45.02 | 0.00 |
| October | 3633.91 | 11-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 29.88 | 0.00 |
| November | 2977.28 | 05-NOV-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.08 |
| December | 2341.27 | 01-DEC-14:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.46 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2269.83 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4168.35 | 1425.00 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 229.20 | 116.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 448.20 | 21-JAN-19:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.06 |
| February | 482.88 | 16-FEB-17:25 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 203.71 |
| March | 1597.04 | 13-MAR-16:30 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.31 |
| April | 1355.52 | 20-APR-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.21 |
| May | 2770.28 | 31-MAY-17:05 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 46.47 | 0.00 |
| June | 3888.75 | 26-JUN-17:12 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 178.42 | 0.00 |
| July | 3471.27 | 15-JUL-17:40 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 177.73 | 0.00 |
| August | 3666.35 | 16-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 114.47 | 0.00 |
| September | 2882.94 | 12-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 98.86 | 0.00 |
| October | 1799.59 | 11-OCT-15:30 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 16.90 | 0.00 |
| November | 678.97 | 07-NOV-15:40 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.51 |
| December | 384.19 | 02-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.27 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 384.19 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3888.75 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 178.42 | 203.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2514.92 | 20-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.54 |
| February | 2328.92 | 18-FEB-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.83 |
| March | 2857.56 | 14-MAR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.62 |
| April | 2058.63 | 19-APR-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.95 |
| May | 2504.27 | 16-MAY-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 52.76 | 0.00 |
| June | 3308.65 | 30-JUN-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 267.28 | 0.00 |
| July | 3356.51 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 114.16 | 0.00 |
| August | 3741.23 | 16-AUG-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 158.25 | 0.00 |
| September | 3519.10 | 09-SEP-12:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 84.13 | 0.00 |
| October | 3151.39 | 11-OCT-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 38.24 | 0.00 |
| November | 2637.93 | 05-NOV-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.79 |
| December | 1958.94 | 01-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.05 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1958.94 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3741.23 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 267.28 | 58.83 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 379.50 | 25-JAN-18:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.50 |
| February | 380.63 | 22-FEB-10:30 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.91 |
| March | 977.81 | 14-MAR-13:40 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.98 |
| April | 1156.40 | 20-APR-13:10 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.43 |
| May | 1927.29 | 17-MAY-13:40 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 77.67 | 0.00 |
| June | 2922.78 | 26-JUN-17:03 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 190.12 | 0.00 |
| July | 2954.67 | 16-JUL-14:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 240.33 | 0.00 |
| August | 2734.49 | 16-AUG-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 158.25 | 0.00 |
| September | 2309.34 | 09-SEP-14:20 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 150.22 | 0.00 |
| October | 1175.01 | 11-OCT-14:20 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 42.85 | 0.00 |
| November | 359.96 | 08-NOV-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.17 |
| December | 373.73 | 02-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.53 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 359.96 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2954.67 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 240.33 | 162.17 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 446.22 | 21-JAN-19:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.08 |
| February | 424.68 | 27-FEB-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.66 |
| March | 663.50 | 14-MAR-16:12 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.38 |
| April | 746.70 | 21-APR-13:30 | 118.75 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.01 |
| May | 1591.03 | 31-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.86 | 0.00 |
| June | 2381.35 | 26-JUN-17:23 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 100.56 | 0.00 |
| July | 2198.63 | 16-JUL-14:40 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 145.12 | 0.00 |
| August | 2180.32 | 16-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 63.81 | 0.00 |
| September | 1732.05 | 09-SEP-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 112.77 | 0.00 |
| October | 928.10 | 11-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 18.02 | 0.00 |
| November | 383.66 | 04-NOV-17:12 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.26 |
| December | 392.64 | 01-DEC-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.49 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 383.66 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2381.35 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 145.12 | 159.49 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 421.13 | 21-JAN-19:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.94 |
| February | 424.66 | 27-FEB-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.66 |
| March | 673.37 | 14-MAR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.07 |
| April | 714.55 | 21-APR-13:30 | 118.75 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.01 |
| May | 1566.44 | 31-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.86 | 0.00 |
| June | 2357.57 | 26-JUN-17:15 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 107.62 | 0.00 |
| July | 2203.09 | 16-JUL-14:40 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 145.12 | 0.00 |
| August | 2161.64 | 16-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 63.81 | 0.00 |
| September | 1737.66 | 09-SEP-14:20 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 90.61 | 0.00 |
| October | 923.94 | 11-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 18.02 | 0.00 |
| November | 376.39 | 07-NOV-00:20 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.43 |
| December | 384.93 | 02-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.78 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 376.39 | 59.38 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2357.57 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 145.12 | 108.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2406.41 | 20-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.37 |
| February | 2142.05 | 18-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.23 |
| March | 2555.73 | 15-MAR-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.50 |
| April | 1704.69 | 21-APR-13:30 | 0.00 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.01 |
| May | 1953.24 | 16-MAY-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 32.14 | 0.00 |
| June | 2572.93 | 30-JUN-14:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 181.44 | 0.00 |
| July | 2680.24 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 68.86 | 0.00 |
| August | 3012.45 | 16-AUG-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 91.56 | 0.00 |
| September | 3039.94 | 28-SEP-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 39.35 | 0.00 |
| October | 2885.75 | 11-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 26.47 | 0.00 |
| November | 2472.02 | 05-NOV-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.74 |
| December | 1892.00 | 02-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.03 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1704.69 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3039.94 | 118.75 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 181.44 | 85.01 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2416.01 | 20-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.37 |
| February | 2156.53 | 18-FEB-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.48 |
| March | 2571.86 | 15-MAR-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.64 |
| April | 1729.04 | 21-APR-13:30 | 0.00 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.01 |
| May | 1970.00 | 16-MAY-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 32.14 | 0.00 |
| June | 2581.60 | 30-JUN-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 171.19 | 0.00 |
| July | 2691.78 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 68.86 | 0.00 |
| August | 3019.91 | 16-AUG-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 91.56 | 0.00 |
| September | 3052.60 | 28-SEP-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 39.35 | 0.00 |
| October | 2886.75 | 11-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 26.47 | 0.00 |
| November | 2478.55 | 05-NOV-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.74 |
| December | 1894.76 | 01-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.89 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1729.04 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3052.60 | 118.75 | 34.72 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 171.19 | 85.01 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.94 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.88 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.31 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.16 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.45 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.98 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.83 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.09 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.79 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.01 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.38 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.01 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.75 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.72 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.20 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.47 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.78 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.79 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.02 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.75 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.68 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.62 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.77 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.35 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.68 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.88 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.58 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.90 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.45 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.11 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.17 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.07 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.57 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.25 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.19 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.94 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.99 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.07 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.94 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.104150E+12 | 70958.64 | 02-JAN-18:49 | 0.533030E+11 | 81226.14 | 05-JAN-09:09 |
| February | 0.946257E+11 | 66669.57 | 13-FEB-18:10 | 0.630732E+11 | 91597.80 | 12-FEB-05:40 |
| March | 0.104449E+12 | 69346.15 | 13-MAR-17:00 | 0.454511E+11 | 94007.99 | 19-MAR-06:00 |
| April | 0.973381E+11 | 65172.04 | 16-APR-17:19 | 0.336199E+11 | 61503.11 | 17-APR-04:00 |
| May | 0.103637E+12 | 73140.38 | 06-MAY-17:49 | 0.314950E+10 | 30241.09 | 03-MAY-02:00 |
| June | 0.121458E+12 | 89448.43 | 26-JUN-17:19 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 0.125404E+12 | 85372.24 | 24-JUL-17:40 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 0.123464E+12 | 91996.99 | 16-AUG-16:40 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 0.112173E+12 | 80137.43 | 02-SEP-16:00 | 0.770638E+09 | 14261.69 | 22-SEP-05:49 |
| October | 0.101946E+12 | 70364.47 | 11-OCT-16:30 | 0.251039E+11 | 64031.96 | 31-OCT-23:00 |
| November | 0.982127E+11 | 65277.05 | 05-NOV-16:00 | 0.404442E+11 | 81124.02 | 30-NOV-05:00 |
| December | 0.103742E+12 | 66309.78 | 20-DEC-18:30 | 0.824005E+11 | 111916.11 | 22-DEC-03:00 |
| Annual Sum or Average | 0.129060E+13 | 0.347316E+12 | ||||
| Minimum of Months | 0.946257E+11 | 65172.04 | 0.00 | 0.00 | ||
| Maximum of Months | 0.125404E+12 | 91996.99 | 0.824005E+11 | 111916.11 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.513598E+10 | 0.389380E+11 | 0.00 | 0.725647E+10 | 0.00 | 0.00 | 0.101811E+10 | 0.00 | 0.00 | 0.00 | 0.433923E+11 | 0.00 |
| February | 0.760941E+10 | 0.432424E+10 | 0.351823E+11 | 0.00 | 0.713940E+10 | 0.00 | 0.00 | 0.782511E+09 | 0.00 | 0.00 | 0.00 | 0.395879E+11 | 0.00 |
| March | 0.845392E+10 | 0.434334E+10 | 0.389781E+11 | 0.00 | 0.725695E+10 | 0.00 | 0.00 | 0.212585E+10 | 0.00 | 0.00 | 0.00 | 0.432908E+11 | 0.00 |
| April | 0.814762E+10 | 0.375315E+10 | 0.376905E+11 | 0.00 | 0.622733E+10 | 0.00 | 0.00 | 0.901984E+09 | 0.00 | 0.00 | 0.00 | 0.406175E+11 | 0.00 |
| May | 0.843904E+10 | 0.348766E+10 | 0.389647E+11 | 0.00 | 0.665494E+10 | 0.00 | 0.00 | 0.607174E+10 | 0.00 | 0.00 | 0.00 | 0.400184E+11 | 0.00 |
| June | 0.817737E+10 | 0.316869E+10 | 0.377173E+11 | 0.00 | 0.116265E+11 | 0.00 | 0.00 | 0.238667E+11 | 0.00 | 0.00 | 0.00 | 0.369018E+11 | 0.00 |
| July | 0.840929E+10 | 0.336733E+10 | 0.389380E+11 | 0.00 | 0.122669E+11 | 0.00 | 0.00 | 0.255889E+11 | 0.00 | 0.00 | 0.00 | 0.368334E+11 | 0.00 |
| August | 0.845392E+10 | 0.370540E+10 | 0.389781E+11 | 0.00 | 0.118233E+11 | 0.00 | 0.00 | 0.241206E+11 | 0.00 | 0.00 | 0.00 | 0.363825E+11 | 0.00 |
| September | 0.814762E+10 | 0.400718E+10 | 0.376905E+11 | 0.00 | 0.963977E+10 | 0.00 | 0.00 | 0.169516E+11 | 0.00 | 0.00 | 0.00 | 0.357362E+11 | 0.00 |
| October | 0.842417E+10 | 0.460501E+10 | 0.389514E+11 | 0.00 | 0.708834E+10 | 0.00 | 0.00 | 0.445701E+10 | 0.00 | 0.00 | 0.00 | 0.384201E+11 | 0.00 |
| November | 0.814762E+10 | 0.485330E+10 | 0.376905E+11 | 0.00 | 0.677607E+10 | 0.00 | 0.00 | 0.174478E+10 | 0.00 | 0.00 | 0.00 | 0.390004E+11 | 0.00 |
| December | 0.840929E+10 | 0.524676E+10 | 0.389380E+11 | 0.00 | 0.837890E+10 | 0.00 | 0.00 | 0.641195E+09 | 0.00 | 0.00 | 0.00 | 0.421279E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.499980E+11 | 0.458657E+12 | 0.00 | 0.102135E+12 | 0.00 | 0.00 | 0.108271E+12 | 0.00 | 0.00 | 0.00 | 0.472309E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.316869E+10 | 0.351823E+11 | 0.00 | 0.622733E+10 | 0.00 | 0.00 | 0.641195E+09 | 0.00 | 0.00 | 0.00 | 0.357362E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.524676E+10 | 0.389781E+11 | 0.00 | 0.122669E+11 | 0.00 | 0.00 | 0.255889E+11 | 0.00 | 0.00 | 0.00 | 0.433923E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.533030E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.630732E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.454511E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.336199E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.314950E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.770638E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.251039E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.404442E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.824005E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.347316E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.824005E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 5067.57 | 05-JAN-05:00 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 5632.58 | 12-FEB-05:40 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 5772.83 | 19-MAR-06:00 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 4379.81 | 17-APR-04:00 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 5979.33 | 31-MAY-16:10 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 9497.87 | 26-JUN-17:19 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 8692.52 | 16-JUL-15:09 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 9288.36 | 16-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 7973.98 | 10-SEP-15:09 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 6669.30 | 11-OCT-14:20 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 5232.51 | 30-NOV-05:00 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 6491.71 | 22-DEC-03:00 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 4379.81 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 9497.87 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 7398.82 | 20-JAN-13:00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 37932.64 | 27-JAN-07:10 | 0.00 |
| February | 6184.71 | 18-FEB-13:00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 36889.13 | 15-FEB-07:19 | 0.00 |
| March | 11191.31 | 13-MAR-15:09 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 35859.82 | 10-MAR-07:10 | 0.00 |
| April | 6111.54 | 20-APR-12:00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 36183.48 | 05-APR-07:30 | 0.00 |
| May | 14018.37 | 31-MAY-16:10 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 33478.37 | 07-MAY-17:40 | 0.00 |
| June | 27189.61 | 26-JUN-15:09 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 30981.31 | 30-JUN-06:40 | 0.00 |
| July | 23777.24 | 17-JUL-13:00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 32707.74 | 30-JUL-06:49 | 0.00 |
| August | 26095.16 | 16-AUG-15:00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 35249.60 | 30-AUG-06:49 | 0.00 |
| September | 20899.23 | 10-SEP-15:09 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 33301.92 | 01-SEP-06:30 | 0.00 |
| October | 16858.13 | 11-OCT-14:09 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 32446.17 | 27-OCT-06:10 | 0.00 |
| November | 9215.20 | 07-NOV-14:20 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 36117.89 | 14-NOV-07:00 | 0.00 |
| December | 5492.19 | 02-DEC-14:00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 34737.07 | 14-DEC-07:40 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 5492.19 | 0.00 | 0.00 | 0.00 | 30981.31 | 0.00 | |||
| Maximum of Months | 27189.61 | 0.00 | 0.00 | 0.00 | 37932.64 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 70958.64 | 02-JAN-18:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2453.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 66669.57 | 13-FEB-18:10 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2245.99 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69346.15 | 13-MAR-17:00 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 3566.05 | 0.00 | 0.00 | 5754.23 | 0.00 |
| April | 65172.04 | 16-APR-17:19 | 5231.74 | 22609.62 | 0.00 | 0.00 | 2948.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 73140.38 | 06-MAY-17:49 | 5231.74 | 22609.62 | 0.00 | 0.00 | 4336.63 | 0.00 | 0.00 | 8184.51 | 0.00 |
| June | 89448.43 | 26-JUN-17:19 | 5231.74 | 22609.62 | 0.00 | 0.00 | 9497.87 | 0.00 | 0.00 | 26290.24 | 0.00 |
| July | 85372.24 | 24-JUL-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7406.73 | 0.00 | 0.00 | 19332.92 | 0.00 |
| August | 91996.99 | 16-AUG-16:40 | 4289.87 | 22709.69 | 0.00 | 0.00 | 9184.82 | 0.00 | 0.00 | 25666.14 | 0.00 |
| September | 80137.43 | 02-SEP-16:00 | 4289.87 | 22609.62 | 0.00 | 0.00 | 6903.27 | 0.00 | 0.00 | 16997.13 | 0.00 |
| October | 70364.47 | 11-OCT-16:30 | 4289.87 | 22709.69 | 0.00 | 0.00 | 5890.67 | 0.00 | 0.00 | 13277.42 | 0.00 |
| November | 65277.05 | 05-NOV-16:00 | 4289.87 | 22609.62 | 3183.33 | 0.00 | 3086.39 | 0.00 | 0.00 | 4241.48 | 0.00 |
| December | 66309.78 | 20-DEC-18:30 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 5431.14 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 65172.04 | 4289.87 | 22609.62 | 0.00 | 0.00 | 2245.99 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 91996.99 | 5231.74 | 22709.69 | 3183.33 | 0.00 | 9497.87 | 0.00 | 0.00 | 26290.24 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 81226.14 | 05-JAN-09:09 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 91597.80 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 94007.99 | 19-MAR-06:00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 61503.11 | 17-APR-04:00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 30241.09 | 03-MAY-02:00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 14261.69 | 22-SEP-05:49 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 64031.96 | 31-OCT-23:00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 81124.02 | 30-NOV-05:00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 111916.11 | 22-DEC-03:00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 111916.11 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.36 | 207.67 | 21.29 | 207.67 | 21.24 |
| February | 473.00 | 21.35 | 250.67 | 21.26 | 250.67 | 21.22 |
| March | 506.00 | 21.64 | 283.33 | 21.45 | 283.33 | 21.35 |
| April | 510.00 | 21.36 | 195.83 | 21.29 | 195.83 | 21.25 |
| May | 507.67 | 22.62 | 39.50 | 22.51 | 39.50 | 22.41 |
| June | 83.00 | 23.83 | 134.67 | 23.93 | 10.50 | 23.94 |
| July | 97.17 | 23.97 | 188.50 | 23.99 | 62.50 | 23.99 |
| August | 40.50 | 23.97 | 247.67 | 24.00 | 13.00 | 24.00 |
| September | 114.67 | 23.61 | 80.33 | 23.77 | 0.00 | 23.77 |
| October | 431.67 | 22.70 | 44.17 | 22.55 | 44.17 | 22.43 |
| November | 507.00 | 22.00 | 77.17 | 21.88 | 77.17 | 21.79 |
| December | 533.00 | 21.40 | 288.33 | 21.30 | 288.33 | 21.25 |
| Annual Sum or Average | 4336.67 | 21.94 | 2037.83 | 21.97 | 1472.67 | 21.84 |
| Minimum of Months | 40.50 | 21.35 | 39.50 | 21.26 | 0.00 | 21.22 |
| Maximum of Months | 533.00 | 23.97 | 288.33 | 24.00 | 288.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.11 | 677.33 | 21.11 | 677.33 | 21.11 |
| February | 672.00 | 21.11 | 649.67 | 21.11 | 649.67 | 21.10 |
| March | 744.00 | 21.24 | 589.67 | 21.18 | 589.67 | 21.16 |
| April | 720.00 | 21.22 | 404.00 | 21.18 | 404.00 | 21.16 |
| May | 740.33 | 22.48 | 73.33 | 22.36 | 73.33 | 22.25 |
| June | 119.50 | 23.83 | 168.50 | 23.93 | 12.50 | 23.93 |
| July | 129.33 | 23.97 | 254.67 | 23.99 | 78.67 | 23.98 |
| August | 93.17 | 23.96 | 251.17 | 23.99 | 20.00 | 23.99 |
| September | 296.83 | 23.58 | 28.17 | 23.61 | 0.00 | 23.61 |
| October | 741.67 | 22.18 | 135.83 | 22.01 | 135.83 | 21.89 |
| November | 720.00 | 21.25 | 358.33 | 21.20 | 358.33 | 21.18 |
| December | 744.00 | 21.13 | 704.33 | 21.12 | 704.33 | 21.11 |
| Annual Sum or Average | 6464.83 | 21.70 | 4295.00 | 21.65 | 3703.67 | 21.53 |
| Minimum of Months | 93.17 | 21.11 | 28.17 | 21.11 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.97 | 704.33 | 23.99 | 704.33 | 23.99 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 140.00 | 22.10 | 51.50 | 21.76 | 51.50 | 21.56 |
| February | 133.00 | 21.80 | 74.33 | 21.49 | 74.33 | 21.34 |
| March | 143.67 | 22.11 | 70.83 | 21.72 | 70.83 | 21.52 |
| April | 140.00 | 22.41 | 40.17 | 22.07 | 40.17 | 21.85 |
| May | 78.00 | 23.32 | 13.17 | 23.19 | 8.33 | 23.00 |
| June | 0.17 | 25.56 | 147.00 | 24.24 | 0.17 | 24.25 |
| July | 1.00 | 25.59 | 140.00 | 24.24 | 1.00 | 24.25 |
| August | 1.00 | 25.63 | 159.00 | 24.24 | 1.00 | 24.25 |
| September | 4.50 | 23.79 | 123.00 | 24.23 | 0.00 | 24.23 |
| October | 58.00 | 22.19 | 36.17 | 22.31 | 18.67 | 22.07 |
| November | 112.00 | 22.38 | 37.50 | 22.01 | 37.17 | 21.79 |
| December | 140.00 | 21.93 | 67.67 | 21.59 | 67.67 | 21.42 |
| Annual Sum or Average | 951.33 | 22.23 | 960.33 | 22.60 | 370.83 | 22.33 |
| Minimum of Months | 0.17 | 21.80 | 13.17 | 21.49 | 0.00 | 21.34 |
| Maximum of Months | 143.67 | 25.63 | 159.00 | 24.24 | 74.33 | 24.25 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.11 | 719.83 | 21.11 | 719.83 | 21.10 |
| February | 672.00 | 21.11 | 646.00 | 21.10 | 646.00 | 21.10 |
| March | 744.00 | 21.25 | 595.17 | 21.19 | 595.17 | 21.16 |
| April | 720.00 | 21.25 | 379.33 | 21.20 | 379.33 | 21.17 |
| May | 744.00 | 22.59 | 73.50 | 22.45 | 73.50 | 22.34 |
| June | 98.00 | 23.81 | 190.17 | 23.94 | 8.83 | 23.94 |
| July | 109.00 | 23.96 | 277.83 | 23.99 | 74.17 | 23.99 |
| August | 85.17 | 23.98 | 285.67 | 23.99 | 17.33 | 24.00 |
| September | 279.33 | 23.59 | 29.17 | 23.63 | 0.00 | 23.63 |
| October | 736.17 | 22.15 | 138.33 | 21.98 | 138.33 | 21.86 |
| November | 720.00 | 21.25 | 369.67 | 21.20 | 369.67 | 21.17 |
| December | 744.00 | 21.12 | 712.17 | 21.11 | 712.17 | 21.11 |
| Annual Sum or Average | 6395.67 | 21.69 | 4416.83 | 21.66 | 3734.33 | 21.53 |
| Minimum of Months | 85.17 | 21.11 | 29.17 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.98 | 719.83 | 23.99 | 719.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.11 | 614.00 | 21.11 | 614.00 | 21.11 |
| February | 672.00 | 21.11 | 621.00 | 21.10 | 621.00 | 21.10 |
| March | 744.00 | 21.24 | 564.33 | 21.18 | 564.33 | 21.16 |
| April | 720.00 | 21.22 | 339.00 | 21.18 | 339.00 | 21.16 |
| May | 743.67 | 22.78 | 64.67 | 22.65 | 64.67 | 22.53 |
| June | 129.00 | 23.94 | 154.83 | 23.97 | 10.50 | 23.97 |
| July | 110.50 | 24.00 | 217.50 | 24.00 | 64.50 | 24.00 |
| August | 139.17 | 23.99 | 210.50 | 24.00 | 15.33 | 24.00 |
| September | 332.83 | 23.75 | 4.00 | 23.75 | 0.00 | 23.75 |
| October | 742.33 | 22.33 | 73.50 | 22.22 | 73.50 | 22.13 |
| November | 720.00 | 21.26 | 271.50 | 21.22 | 271.50 | 21.19 |
| December | 744.00 | 21.12 | 685.83 | 21.11 | 685.83 | 21.11 |
| Annual Sum or Average | 6541.50 | 21.78 | 3820.67 | 21.70 | 3324.17 | 21.57 |
| Minimum of Months | 110.50 | 21.11 | 4.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 24.00 | 685.83 | 24.00 | 685.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.11 | 617.83 | 21.11 | 617.83 | 21.11 |
| February | 672.00 | 21.11 | 620.50 | 21.10 | 620.50 | 21.10 |
| March | 744.00 | 21.24 | 563.83 | 21.18 | 563.83 | 21.16 |
| April | 720.00 | 21.22 | 338.83 | 21.18 | 338.83 | 21.16 |
| May | 743.50 | 22.80 | 64.50 | 22.66 | 64.50 | 22.55 |
| June | 128.83 | 23.94 | 155.67 | 23.97 | 10.33 | 23.97 |
| July | 110.00 | 24.00 | 219.00 | 24.00 | 63.67 | 24.00 |
| August | 138.67 | 23.99 | 213.00 | 24.00 | 15.17 | 24.00 |
| September | 332.33 | 23.75 | 4.00 | 23.75 | 0.00 | 23.75 |
| October | 742.33 | 22.33 | 73.50 | 22.22 | 73.50 | 22.12 |
| November | 720.00 | 21.26 | 273.50 | 21.22 | 273.50 | 21.19 |
| December | 744.00 | 21.12 | 686.50 | 21.11 | 686.50 | 21.11 |
| Annual Sum or Average | 6539.67 | 21.78 | 3830.67 | 21.70 | 3328.17 | 21.57 |
| Minimum of Months | 110.00 | 21.11 | 4.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 24.00 | 686.50 | 24.00 | 686.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.68 | 89.33 | 21.60 | 89.33 | 21.53 |
| February | 473.00 | 21.54 | 217.83 | 21.40 | 217.83 | 21.33 |
| March | 506.00 | 21.78 | 214.50 | 21.58 | 214.50 | 21.47 |
| April | 510.00 | 21.43 | 129.33 | 21.36 | 129.33 | 21.32 |
| May | 501.33 | 23.00 | 26.83 | 22.90 | 26.83 | 22.82 |
| June | 69.00 | 23.94 | 129.00 | 23.98 | 6.67 | 23.98 |
| July | 72.50 | 24.00 | 188.33 | 24.00 | 45.33 | 24.00 |
| August | 30.67 | 24.00 | 221.50 | 24.00 | 9.00 | 24.00 |
| September | 103.50 | 23.79 | 58.33 | 23.87 | 0.00 | 23.87 |
| October | 408.17 | 22.92 | 29.33 | 22.80 | 28.17 | 22.70 |
| November | 492.33 | 22.38 | 54.17 | 22.25 | 54.17 | 22.15 |
| December | 533.00 | 21.61 | 204.67 | 21.47 | 204.67 | 21.39 |
| Annual Sum or Average | 4232.50 | 22.14 | 1563.17 | 22.16 | 1025.83 | 22.03 |
| Minimum of Months | 30.67 | 21.43 | 26.83 | 21.36 | 0.00 | 21.32 |
| Maximum of Months | 533.00 | 24.00 | 221.50 | 24.00 | 217.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.66 | 108.67 | 21.56 | 108.67 | 21.50 |
| February | 473.00 | 21.53 | 229.17 | 21.39 | 229.17 | 21.32 |
| March | 506.00 | 21.78 | 223.83 | 21.57 | 223.83 | 21.46 |
| April | 510.00 | 21.43 | 138.83 | 21.36 | 138.83 | 21.32 |
| May | 492.50 | 23.06 | 27.17 | 22.96 | 27.17 | 22.87 |
| June | 39.50 | 23.97 | 140.83 | 23.99 | 2.67 | 23.99 |
| July | 56.67 | 24.00 | 202.50 | 24.00 | 38.17 | 24.00 |
| August | 10.17 | 24.00 | 256.83 | 24.00 | 8.00 | 24.00 |
| September | 85.67 | 23.79 | 88.83 | 23.90 | 0.00 | 23.90 |
| October | 393.00 | 22.92 | 31.33 | 22.80 | 29.00 | 22.69 |
| November | 490.83 | 22.38 | 58.67 | 22.24 | 58.67 | 22.13 |
| December | 533.00 | 21.59 | 226.83 | 21.44 | 226.83 | 21.36 |
| Annual Sum or Average | 4123.33 | 22.10 | 1733.50 | 22.15 | 1091.00 | 22.00 |
| Minimum of Months | 10.17 | 21.43 | 27.17 | 21.36 | 0.00 | 21.32 |
| Maximum of Months | 533.00 | 24.00 | 256.83 | 24.00 | 229.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 526.00 | 21.98 | 75.33 | 21.87 | 75.33 | 21.78 |
| February | 464.50 | 21.83 | 163.00 | 21.64 | 163.00 | 21.53 |
| March | 487.33 | 22.05 | 103.33 | 21.88 | 103.33 | 21.76 |
| April | 499.00 | 22.02 | 90.17 | 21.88 | 90.17 | 21.77 |
| May | 287.00 | 23.24 | 14.17 | 23.24 | 4.17 | 23.21 |
| June | 32.33 | 23.97 | 174.33 | 24.00 | 1.33 | 24.00 |
| July | 44.17 | 24.00 | 210.00 | 24.00 | 27.83 | 24.00 |
| August | 28.67 | 23.99 | 257.33 | 24.00 | 8.33 | 24.00 |
| September | 148.00 | 23.63 | 54.83 | 23.73 | 0.00 | 23.73 |
| October | 437.17 | 22.68 | 50.83 | 22.51 | 50.83 | 22.38 |
| November | 490.50 | 22.24 | 57.17 | 22.12 | 57.17 | 22.02 |
| December | 530.67 | 21.62 | 227.83 | 21.46 | 227.83 | 21.38 |
| Annual Sum or Average | 3975.33 | 22.24 | 1478.33 | 22.31 | 809.33 | 22.17 |
| Minimum of Months | 28.67 | 21.62 | 14.17 | 21.46 | 0.00 | 21.38 |
| Maximum of Months | 530.67 | 24.00 | 257.33 | 24.00 | 227.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.22 | 365.00 | 21.18 | 365.00 | 21.16 |
| February | 672.00 | 21.21 | 378.33 | 21.17 | 378.33 | 21.15 |
| March | 744.00 | 21.76 | 259.17 | 21.59 | 259.17 | 21.49 |
| April | 720.00 | 21.77 | 127.33 | 21.67 | 127.33 | 21.60 |
| May | 449.00 | 23.24 | 14.67 | 23.23 | 5.67 | 23.21 |
| June | 37.33 | 23.98 | 244.00 | 24.00 | 1.00 | 24.00 |
| July | 60.83 | 24.00 | 302.00 | 24.00 | 40.00 | 24.00 |
| August | 59.00 | 23.98 | 275.17 | 24.00 | 11.50 | 24.00 |
| September | 322.17 | 23.58 | 24.17 | 23.61 | 0.00 | 23.61 |
| October | 741.50 | 22.26 | 109.17 | 22.11 | 109.17 | 22.00 |
| November | 720.00 | 21.40 | 245.33 | 21.33 | 245.33 | 21.28 |
| December | 744.00 | 21.17 | 595.33 | 21.14 | 595.33 | 21.13 |
| Annual Sum or Average | 6013.83 | 21.85 | 2939.67 | 21.88 | 2137.83 | 21.74 |
| Minimum of Months | 37.33 | 21.17 | 14.67 | 21.14 | 0.00 | 21.13 |
| Maximum of Months | 744.00 | 24.00 | 595.33 | 24.00 | 595.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 526.17 | 21.97 | 75.00 | 21.86 | 75.00 | 21.78 |
| February | 461.67 | 21.81 | 175.33 | 21.62 | 175.33 | 21.51 |
| March | 490.00 | 22.04 | 102.33 | 21.88 | 102.33 | 21.76 |
| April | 500.00 | 22.04 | 87.83 | 21.90 | 87.83 | 21.80 |
| May | 275.50 | 23.22 | 6.50 | 23.19 | 4.67 | 23.16 |
| June | 23.17 | 23.96 | 170.17 | 23.99 | 0.00 | 23.99 |
| July | 41.33 | 23.99 | 221.67 | 24.00 | 27.33 | 24.00 |
| August | 25.00 | 23.99 | 257.17 | 24.00 | 7.33 | 24.00 |
| September | 147.33 | 23.64 | 53.17 | 23.74 | 0.00 | 23.74 |
| October | 437.83 | 22.67 | 53.67 | 22.52 | 50.00 | 22.39 |
| November | 493.67 | 22.22 | 63.67 | 22.09 | 63.67 | 21.99 |
| December | 530.50 | 21.61 | 231.33 | 21.46 | 231.33 | 21.37 |
| Annual Sum or Average | 3952.17 | 22.23 | 1497.83 | 22.29 | 824.83 | 22.15 |
| Minimum of Months | 23.17 | 21.61 | 6.50 | 21.46 | 0.00 | 21.37 |
| Maximum of Months | 530.50 | 23.99 | 257.17 | 24.00 | 231.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.20 | 369.67 | 21.17 | 369.67 | 21.15 |
| February | 672.00 | 21.22 | 385.17 | 21.17 | 385.17 | 21.15 |
| March | 744.00 | 21.79 | 254.17 | 21.62 | 254.17 | 21.51 |
| April | 717.33 | 21.84 | 138.83 | 21.72 | 138.83 | 21.63 |
| May | 427.33 | 23.26 | 10.00 | 23.23 | 7.00 | 23.20 |
| June | 23.00 | 23.95 | 264.00 | 24.00 | 0.00 | 24.00 |
| July | 57.33 | 23.99 | 319.17 | 24.00 | 43.33 | 24.00 |
| August | 52.17 | 23.99 | 310.50 | 24.00 | 9.67 | 24.00 |
| September | 303.33 | 23.61 | 20.50 | 23.63 | 0.00 | 23.63 |
| October | 736.67 | 22.23 | 112.17 | 22.08 | 112.17 | 21.97 |
| November | 720.00 | 21.40 | 250.50 | 21.32 | 250.50 | 21.28 |
| December | 744.00 | 21.16 | 596.67 | 21.13 | 596.67 | 21.12 |
| Annual Sum or Average | 5941.17 | 21.83 | 3031.33 | 21.88 | 2167.17 | 21.74 |
| Minimum of Months | 23.00 | 21.16 | 10.00 | 21.13 | 0.00 | 21.12 |
| Maximum of Months | 744.00 | 23.99 | 596.67 | 24.00 | 596.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.24 | 241.83 | 21.21 | 241.83 | 21.19 |
| February | 672.00 | 21.21 | 376.50 | 21.17 | 376.50 | 21.15 |
| March | 744.00 | 21.78 | 154.33 | 21.66 | 154.33 | 21.58 |
| April | 720.00 | 21.86 | 100.00 | 21.77 | 100.00 | 21.69 |
| May | 425.33 | 23.40 | 4.00 | 23.40 | 0.00 | 23.40 |
| June | 55.17 | 24.00 | 189.33 | 24.00 | 0.00 | 24.00 |
| July | 67.83 | 24.00 | 249.17 | 24.00 | 32.67 | 24.00 |
| August | 111.67 | 24.00 | 214.83 | 24.00 | 8.50 | 24.00 |
| September | 361.83 | 23.78 | 3.83 | 23.78 | 0.00 | 23.78 |
| October | 742.50 | 22.48 | 55.33 | 22.38 | 55.33 | 22.30 |
| November | 720.00 | 21.46 | 151.17 | 21.40 | 151.17 | 21.35 |
| December | 744.00 | 21.18 | 466.33 | 21.15 | 466.33 | 21.14 |
| Annual Sum or Average | 6108.33 | 21.95 | 2206.67 | 21.96 | 1586.67 | 21.83 |
| Minimum of Months | 55.17 | 21.18 | 3.83 | 21.15 | 0.00 | 21.14 |
| Maximum of Months | 744.00 | 24.00 | 466.33 | 24.00 | 466.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.24 | 242.00 | 21.21 | 242.00 | 21.19 |
| February | 672.00 | 21.22 | 376.83 | 21.17 | 376.83 | 21.15 |
| March | 744.00 | 21.78 | 157.00 | 21.67 | 157.00 | 21.58 |
| April | 720.00 | 21.87 | 99.17 | 21.78 | 99.17 | 21.70 |
| May | 424.17 | 23.40 | 4.00 | 23.40 | 0.00 | 23.40 |
| June | 53.67 | 24.00 | 188.33 | 24.00 | 0.00 | 24.00 |
| July | 68.00 | 24.00 | 250.17 | 24.00 | 32.50 | 24.00 |
| August | 111.00 | 24.00 | 216.83 | 24.00 | 8.50 | 24.00 |
| September | 361.67 | 23.78 | 4.00 | 23.79 | 0.00 | 23.79 |
| October | 742.50 | 22.47 | 55.33 | 22.38 | 55.33 | 22.29 |
| November | 720.00 | 21.46 | 151.50 | 21.40 | 151.50 | 21.35 |
| December | 744.00 | 21.18 | 467.67 | 21.15 | 467.67 | 21.14 |
| Annual Sum or Average | 6105.00 | 21.95 | 2212.83 | 21.96 | 1590.50 | 21.83 |
| Minimum of Months | 53.67 | 21.18 | 4.00 | 21.15 | 0.00 | 21.14 |
| Maximum of Months | 744.00 | 24.00 | 467.67 | 24.00 | 467.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 516.00 | 22.51 | 33.83 | 22.42 | 33.83 | 22.35 |
| February | 459.67 | 22.18 | 94.50 | 22.00 | 94.50 | 21.87 |
| March | 492.33 | 22.25 | 26.00 | 22.19 | 26.00 | 22.14 |
| April | 504.17 | 22.34 | 36.17 | 22.25 | 36.17 | 22.18 |
| May | 247.17 | 23.41 | 5.00 | 23.42 | 0.00 | 23.42 |
| June | 36.50 | 24.00 | 146.83 | 24.00 | 0.67 | 24.00 |
| July | 45.83 | 24.00 | 193.17 | 24.00 | 23.83 | 24.00 |
| August | 28.50 | 24.00 | 214.00 | 24.00 | 7.83 | 24.00 |
| September | 130.67 | 23.81 | 34.33 | 23.85 | 0.00 | 23.85 |
| October | 417.00 | 22.98 | 28.67 | 22.87 | 26.50 | 22.77 |
| November | 473.00 | 22.67 | 42.17 | 22.54 | 42.17 | 22.43 |
| December | 524.83 | 21.94 | 112.67 | 21.79 | 112.67 | 21.69 |
| Annual Sum or Average | 3875.67 | 22.55 | 967.33 | 22.62 | 404.17 | 22.52 |
| Minimum of Months | 28.50 | 21.94 | 5.00 | 21.79 | 0.00 | 21.69 |
| Maximum of Months | 524.83 | 24.00 | 214.00 | 24.00 | 112.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 516.00 | 22.51 | 33.83 | 22.42 | 33.83 | 22.35 |
| February | 458.83 | 22.18 | 95.17 | 21.99 | 95.17 | 21.86 |
| March | 492.17 | 22.25 | 25.83 | 22.19 | 25.83 | 22.14 |
| April | 504.00 | 22.34 | 36.00 | 22.26 | 36.00 | 22.18 |
| May | 245.83 | 23.41 | 5.00 | 23.42 | 0.00 | 23.42 |
| June | 35.67 | 24.00 | 146.50 | 24.00 | 0.50 | 24.00 |
| July | 46.00 | 24.00 | 192.50 | 24.00 | 23.83 | 24.00 |
| August | 28.83 | 24.00 | 214.67 | 24.00 | 7.83 | 24.00 |
| September | 130.33 | 23.81 | 33.67 | 23.85 | 0.00 | 23.85 |
| October | 417.17 | 22.98 | 28.83 | 22.87 | 26.50 | 22.77 |
| November | 472.83 | 22.66 | 42.17 | 22.54 | 42.17 | 22.43 |
| December | 524.67 | 21.94 | 112.83 | 21.79 | 112.83 | 21.69 |
| Annual Sum or Average | 3872.33 | 22.55 | 967.00 | 22.62 | 404.50 | 22.52 |
| Minimum of Months | 28.83 | 21.94 | 5.00 | 21.79 | 0.00 | 21.69 |
| Maximum of Months | 524.67 | 24.00 | 214.67 | 24.00 | 112.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 520.83 | 21.43 | 325.83 | 21.30 | 325.83 | 21.25 |
| February | 454.17 | 21.36 | 312.50 | 21.26 | 311.50 | 21.21 |
| March | 477.50 | 21.61 | 294.00 | 21.42 | 293.50 | 21.33 |
| April | 486.33 | 21.51 | 241.00 | 21.37 | 241.00 | 21.30 |
| May | 381.17 | 22.26 | 62.33 | 22.26 | 37.33 | 22.17 |
| June | 154.17 | 23.51 | 186.50 | 23.77 | 11.67 | 23.77 |
| July | 164.00 | 23.60 | 266.17 | 23.83 | 60.50 | 23.83 |
| August | 153.83 | 23.53 | 246.17 | 23.80 | 33.17 | 23.80 |
| September | 272.17 | 22.93 | 102.67 | 23.10 | 15.67 | 23.02 |
| October | 457.50 | 21.81 | 194.00 | 21.68 | 176.67 | 21.55 |
| November | 479.17 | 21.55 | 252.17 | 21.40 | 250.50 | 21.33 |
| December | 517.67 | 21.31 | 414.67 | 21.22 | 414.67 | 21.18 |
| Annual Sum or Average | 4518.50 | 21.87 | 2898.00 | 21.89 | 2172.00 | 21.74 |
| Minimum of Months | 153.83 | 21.31 | 62.33 | 21.22 | 11.67 | 21.18 |
| Maximum of Months | 520.83 | 23.60 | 414.67 | 23.83 | 414.67 | 23.83 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.21 | 617.17 | 21.16 | 617.17 | 21.14 |
| February | 672.00 | 21.21 | 547.00 | 21.16 | 547.00 | 21.14 |
| March | 736.33 | 21.57 | 465.50 | 21.39 | 465.50 | 21.31 |
| April | 701.83 | 21.61 | 336.17 | 21.45 | 336.17 | 21.36 |
| May | 532.50 | 22.37 | 86.17 | 22.36 | 49.83 | 22.27 |
| June | 152.33 | 23.55 | 341.67 | 23.86 | 11.33 | 23.86 |
| July | 177.17 | 23.65 | 419.83 | 23.88 | 71.17 | 23.87 |
| August | 189.50 | 23.50 | 370.33 | 23.81 | 43.17 | 23.81 |
| September | 401.83 | 22.89 | 101.83 | 22.97 | 24.83 | 22.88 |
| October | 722.33 | 21.74 | 311.17 | 21.55 | 311.17 | 21.44 |
| November | 720.00 | 21.34 | 501.83 | 21.24 | 501.83 | 21.20 |
| December | 744.00 | 21.18 | 676.83 | 21.14 | 676.83 | 21.13 |
| Annual Sum or Average | 6493.83 | 21.75 | 4775.50 | 21.79 | 3656.00 | 21.65 |
| Minimum of Months | 152.33 | 21.18 | 86.17 | 21.14 | 11.33 | 21.13 |
| Maximum of Months | 744.00 | 23.65 | 676.83 | 23.88 | 676.83 | 23.87 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 522.00 | 21.43 | 327.50 | 21.30 | 327.50 | 21.25 |
| February | 452.67 | 21.33 | 314.17 | 21.24 | 314.17 | 21.20 |
| March | 480.67 | 21.58 | 299.67 | 21.40 | 299.67 | 21.32 |
| April | 493.67 | 21.53 | 246.17 | 21.39 | 246.17 | 21.31 |
| May | 383.33 | 22.30 | 49.17 | 22.25 | 36.17 | 22.16 |
| June | 141.17 | 23.54 | 174.00 | 23.79 | 9.67 | 23.79 |
| July | 158.17 | 23.65 | 263.83 | 23.84 | 61.17 | 23.84 |
| August | 148.00 | 23.55 | 232.67 | 23.81 | 33.83 | 23.81 |
| September | 273.50 | 22.96 | 93.83 | 23.11 | 15.00 | 23.03 |
| October | 460.17 | 21.82 | 198.83 | 21.69 | 180.33 | 21.56 |
| November | 476.50 | 21.52 | 253.67 | 21.38 | 253.67 | 21.30 |
| December | 515.00 | 21.30 | 416.00 | 21.21 | 416.00 | 21.18 |
| Annual Sum or Average | 4504.83 | 21.86 | 2869.50 | 21.87 | 2193.33 | 21.72 |
| Minimum of Months | 141.17 | 21.30 | 49.17 | 21.21 | 9.67 | 21.18 |
| Maximum of Months | 522.00 | 23.65 | 416.00 | 23.84 | 416.00 | 23.84 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.18 | 624.67 | 21.14 | 624.67 | 21.13 |
| February | 672.00 | 21.20 | 539.17 | 21.16 | 539.17 | 21.14 |
| March | 744.00 | 21.64 | 451.83 | 21.44 | 451.83 | 21.34 |
| April | 696.17 | 21.64 | 323.67 | 21.47 | 323.67 | 21.38 |
| May | 502.83 | 22.41 | 76.00 | 22.41 | 41.83 | 22.32 |
| June | 137.00 | 23.55 | 365.33 | 23.87 | 9.50 | 23.87 |
| July | 164.67 | 23.66 | 433.83 | 23.89 | 68.83 | 23.89 |
| August | 169.50 | 23.52 | 384.83 | 23.84 | 41.17 | 23.84 |
| September | 383.83 | 22.95 | 108.00 | 23.05 | 22.17 | 22.96 |
| October | 738.67 | 21.80 | 296.17 | 21.60 | 296.17 | 21.49 |
| November | 720.00 | 21.33 | 502.17 | 21.23 | 502.17 | 21.19 |
| December | 744.00 | 21.16 | 682.67 | 21.13 | 682.67 | 21.12 |
| Annual Sum or Average | 6416.67 | 21.75 | 4788.33 | 21.81 | 3603.83 | 21.66 |
| Minimum of Months | 137.00 | 21.16 | 76.00 | 21.13 | 9.50 | 21.12 |
| Maximum of Months | 744.00 | 23.66 | 682.67 | 23.89 | 682.67 | 23.89 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.18 | 587.83 | 21.14 | 587.83 | 21.13 |
| February | 672.00 | 21.18 | 530.50 | 21.14 | 530.50 | 21.13 |
| March | 744.00 | 21.57 | 442.17 | 21.40 | 442.17 | 21.32 |
| April | 720.00 | 21.66 | 281.17 | 21.50 | 281.17 | 21.42 |
| May | 558.17 | 22.69 | 45.33 | 22.62 | 36.17 | 22.53 |
| June | 115.17 | 23.73 | 251.00 | 23.91 | 9.17 | 23.92 |
| July | 160.17 | 23.83 | 322.83 | 23.94 | 70.33 | 23.94 |
| August | 153.33 | 23.73 | 296.00 | 23.90 | 35.67 | 23.91 |
| September | 422.17 | 23.17 | 46.67 | 23.13 | 18.50 | 23.06 |
| October | 744.00 | 21.79 | 261.50 | 21.61 | 261.50 | 21.51 |
| November | 720.00 | 21.31 | 458.50 | 21.23 | 458.50 | 21.19 |
| December | 744.00 | 21.16 | 678.67 | 21.13 | 678.67 | 21.12 |
| Annual Sum or Average | 6497.00 | 21.79 | 4202.17 | 21.76 | 3410.17 | 21.63 |
| Minimum of Months | 115.17 | 21.16 | 45.33 | 21.13 | 9.17 | 21.12 |
| Maximum of Months | 744.00 | 23.83 | 678.67 | 23.94 | 678.67 | 23.94 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.17 | 588.50 | 21.14 | 588.50 | 21.13 |
| February | 672.00 | 21.18 | 529.83 | 21.15 | 529.83 | 21.13 |
| March | 744.00 | 21.58 | 441.00 | 21.40 | 441.00 | 21.32 |
| April | 720.00 | 21.67 | 281.67 | 21.51 | 281.67 | 21.42 |
| May | 555.83 | 22.69 | 45.00 | 22.62 | 35.83 | 22.53 |
| June | 115.50 | 23.73 | 251.17 | 23.91 | 9.33 | 23.92 |
| July | 159.33 | 23.83 | 326.50 | 23.94 | 70.00 | 23.94 |
| August | 153.33 | 23.73 | 300.00 | 23.90 | 36.00 | 23.91 |
| September | 421.00 | 23.17 | 46.67 | 23.14 | 18.50 | 23.06 |
| October | 744.00 | 21.80 | 261.83 | 21.61 | 261.83 | 21.51 |
| November | 720.00 | 21.31 | 461.33 | 21.23 | 461.33 | 21.19 |
| December | 744.00 | 21.16 | 679.17 | 21.13 | 679.17 | 21.12 |
| Annual Sum or Average | 6493.00 | 21.79 | 4212.67 | 21.77 | 3413.00 | 21.63 |
| Minimum of Months | 115.50 | 21.16 | 45.00 | 21.13 | 9.33 | 21.12 |
| Maximum of Months | 744.00 | 23.83 | 679.17 | 23.94 | 679.17 | 23.94 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 516.50 | 21.55 | 239.17 | 21.41 | 239.17 | 21.34 |
| February | 454.67 | 21.47 | 263.50 | 21.33 | 263.50 | 21.27 |
| March | 483.67 | 21.74 | 254.67 | 21.52 | 254.67 | 21.41 |
| April | 498.50 | 21.66 | 186.67 | 21.51 | 186.67 | 21.42 |
| May | 381.00 | 22.59 | 32.33 | 22.53 | 24.00 | 22.45 |
| June | 120.33 | 23.70 | 150.50 | 23.86 | 9.83 | 23.87 |
| July | 151.33 | 23.79 | 221.00 | 23.91 | 59.50 | 23.91 |
| August | 115.67 | 23.76 | 222.50 | 23.91 | 26.00 | 23.92 |
| September | 254.00 | 23.19 | 71.83 | 23.30 | 7.83 | 23.25 |
| October | 461.00 | 22.03 | 134.33 | 21.88 | 121.17 | 21.75 |
| November | 474.83 | 21.70 | 182.17 | 21.53 | 182.17 | 21.44 |
| December | 515.33 | 21.40 | 366.17 | 21.28 | 366.17 | 21.22 |
| Annual Sum or Average | 4426.83 | 22.00 | 2324.83 | 21.98 | 1740.67 | 21.83 |
| Minimum of Months | 115.67 | 21.40 | 32.33 | 21.28 | 7.83 | 21.22 |
| Maximum of Months | 516.50 | 23.79 | 366.17 | 23.91 | 366.17 | 23.92 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 516.50 | 21.55 | 241.00 | 21.41 | 241.00 | 21.33 |
| February | 454.17 | 21.46 | 264.33 | 21.33 | 264.33 | 21.27 |
| March | 483.83 | 21.74 | 255.33 | 21.52 | 255.33 | 21.41 |
| April | 498.50 | 21.66 | 187.33 | 21.51 | 187.33 | 21.42 |
| May | 381.00 | 22.58 | 32.67 | 22.53 | 24.17 | 22.45 |
| June | 121.00 | 23.70 | 149.00 | 23.86 | 9.83 | 23.87 |
| July | 151.17 | 23.79 | 220.83 | 23.91 | 59.50 | 23.91 |
| August | 115.83 | 23.76 | 220.33 | 23.91 | 26.17 | 23.92 |
| September | 254.50 | 23.19 | 72.00 | 23.30 | 7.83 | 23.25 |
| October | 460.83 | 22.02 | 135.00 | 21.88 | 121.67 | 21.75 |
| November | 474.67 | 21.70 | 183.83 | 21.53 | 183.83 | 21.44 |
| December | 514.83 | 21.40 | 367.50 | 21.27 | 367.50 | 21.22 |
| Annual Sum or Average | 4426.83 | 22.00 | 2329.17 | 21.98 | 1748.50 | 21.83 |
| Minimum of Months | 115.83 | 21.40 | 32.67 | 21.27 | 7.83 | 21.22 |
| Maximum of Months | 516.50 | 23.79 | 367.50 | 23.91 | 367.50 | 23.92 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.01 | 694.17 | 21.00 | 694.17 | 21.00 |
| February | 654.83 | 20.78 | 423.17 | 20.63 | 423.17 | 20.56 |
| March | 697.00 | 21.50 | 414.00 | 21.66 | 386.67 | 21.68 |
| April | 656.33 | 21.63 | 508.67 | 21.74 | 460.50 | 21.70 |
| May | 729.67 | 24.04 | 684.50 | 24.14 | 673.67 | 24.17 |
| June | 720.00 | 25.97 | 720.00 | 25.97 | 720.00 | 25.97 |
| July | 744.00 | 26.02 | 744.00 | 26.02 | 744.00 | 26.02 |
| August | 744.00 | 25.89 | 744.00 | 25.89 | 744.00 | 25.89 |
| September | 715.50 | 25.06 | 720.00 | 25.06 | 715.50 | 25.06 |
| October | 744.00 | 22.29 | 723.67 | 22.30 | 723.67 | 22.31 |
| November | 719.00 | 21.39 | 661.50 | 21.40 | 661.50 | 21.40 |
| December | 732.50 | 20.37 | 373.50 | 20.02 | 371.33 | 19.84 |
| Annual Sum or Average | 8600.83 | 23.03 | 7411.17 | 23.17 | 7318.17 | 23.22 |
| Minimum of Months | 654.83 | 20.37 | 373.50 | 20.02 | 371.33 | 19.84 |
| Maximum of Months | 744.00 | 26.02 | 744.00 | 26.02 | 744.00 | 26.02 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 18.75 | 580.00 | 18.42 | 580.00 | 18.29 |
| February | 672.00 | 18.28 | 552.67 | 17.98 | 552.67 | 17.87 |
| March | 744.00 | 19.58 | 507.50 | 19.08 | 507.50 | 18.87 |
| April | 720.00 | 19.79 | 410.00 | 19.31 | 410.00 | 19.08 |
| May | 636.33 | 22.48 | 134.33 | 22.33 | 105.50 | 22.14 |
| June | 200.83 | 25.50 | 686.67 | 26.02 | 185.50 | 25.98 |
| July | 246.17 | 25.67 | 726.33 | 26.14 | 239.67 | 26.06 |
| August | 208.67 | 25.58 | 706.50 | 26.06 | 192.67 | 26.03 |
| September | 159.83 | 23.95 | 541.67 | 25.55 | 69.17 | 25.55 |
| October | 629.67 | 21.33 | 221.50 | 20.85 | 180.83 | 20.38 |
| November | 718.67 | 19.89 | 367.67 | 19.27 | 367.67 | 18.97 |
| December | 744.00 | 18.30 | 620.67 | 18.01 | 620.67 | 17.90 |
| Annual Sum or Average | 6424.17 | 20.44 | 6055.50 | 21.06 | 4011.83 | 20.66 |
| Minimum of Months | 159.83 | 18.28 | 134.33 | 17.98 | 69.17 | 17.87 |
| Maximum of Months | 744.00 | 25.67 | 726.33 | 26.14 | 620.67 | 26.06 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 22.84 | 744.00 | 22.84 | 744.00 | 22.84 |
| February | 672.00 | 22.55 | 643.33 | 22.57 | 643.33 | 22.58 |
| March | 744.00 | 23.17 | 680.67 | 23.22 | 680.67 | 23.24 |
| April | 692.33 | 23.23 | 634.00 | 23.30 | 622.83 | 23.32 |
| May | 744.00 | 25.17 | 735.50 | 25.18 | 735.50 | 25.19 |
| June | 720.00 | 26.09 | 720.00 | 26.09 | 720.00 | 26.09 |
| July | 744.00 | 26.09 | 744.00 | 26.09 | 744.00 | 26.09 |
| August | 744.00 | 26.04 | 744.00 | 26.04 | 744.00 | 26.04 |
| September | 720.00 | 25.75 | 720.00 | 25.75 | 720.00 | 25.75 |
| October | 744.00 | 24.03 | 744.00 | 24.03 | 744.00 | 24.03 |
| November | 720.00 | 23.05 | 706.00 | 23.06 | 706.00 | 23.07 |
| December | 744.00 | 22.23 | 505.33 | 22.40 | 505.33 | 22.47 |
| Annual Sum or Average | 8732.33 | 24.20 | 8320.83 | 24.26 | 8309.67 | 24.29 |
| Minimum of Months | 672.00 | 22.23 | 505.33 | 22.40 | 505.33 | 22.47 |
| Maximum of Months | 744.00 | 26.09 | 744.00 | 26.09 | 744.00 | 26.09 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 17929408.60 | 4808653.27 | 20.98 | 17929408.60 | -0.0 | 0.00 | 0.09 | 20-JAN-15:10 | 0.00 | 01-JAN-00:10 | 476.35 | 20-JAN-15:10 | 476.35 | 20-JAN-15:10 | 0.00 | 20-JAN-14:10 | 127.13 | 20-JAN-15:10 | 0.00 | 01-JAN-00:10 |
| February | 2806987.65 | 755582.72 | 7.39 | 2806987.65 | 0.00 | 0.00 | 0.06 | 26-FEB-17:08 | 0.00 | 01-FEB-00:10 | 302.74 | 26-FEB-17:08 | 302.74 | 26-FEB-17:08 | 0.00 | 18-FEB-14:20 | 81.19 | 26-FEB-17:08 | 0.00 | 01-FEB-00:10 |
| March | 0.106968E+09 | 28331038.40 | 61.17 | 0.106968E+09 | 0.00 | 0.00 | 0.24 | 13-MAR-16:07 | 0.00 | 01-MAR-00:10 | 1341.78 | 13-MAR-16:07 | 1341.78 | 13-MAR-16:07 | 0.00 | 13-MAR-15:00 | 349.71 | 13-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 1350547.03 | 363608.50 | 3.00 | 1350547.03 | 0.00 | 0.00 | 0.05 | 08-APR-17:17 | 0.00 | 01-APR-00:10 | 270.76 | 08-APR-17:17 | 270.76 | 08-APR-17:17 | 0.00 | 08-APR-17:13 | 72.68 | 08-APR-17:17 | 0.00 | 01-APR-00:10 |
| May | 0.168898E+09 | 45601047.43 | 129.03 | 0.168576E+09 | 321494.79 | 0.00 | 0.20 | 31-MAY-16:03 | 0.00 | 01-MAY-00:10 | 1113.44 | 31-MAY-16:15 | 1113.44 | 31-MAY-16:15 | 16.15 | 31-MAY-19:20 | 305.95 | 31-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.220315E+10 | 0.601605E+09 | 649.97 | 0.212961E+10 | 73540566.82 | 0.00 | 0.53 | 26-JUN-17:20 | 0.00 | 01-JUN-00:10 | 2719.29 | 26-JUN-17:20 | 2719.29 | 26-JUN-17:20 | 321.28 | 18-JUN-10:30 | 827.39 | 26-JUN-17:20 | 0.00 | 01-JUN-00:10 |
| July | 0.247658E+10 | 0.671358E+09 | 710.52 | 0.235496E+10 | 0.121621E+09 | 0.00 | 0.46 | 15-JUL-17:20 | 0.00 | 02-JUL-04:00 | 2432.12 | 15-JUL-17:30 | 2432.12 | 15-JUL-17:30 | 404.28 | 30-JUL-16:10 | 704.19 | 15-JUL-17:20 | 0.00 | 01-JUL-00:10 |
| August | 0.278847E+10 | 0.747067E+09 | 727.53 | 0.266941E+10 | 0.119054E+09 | 0.00 | 0.56 | 16-AUG-16:01 | 0.00 | 01-AUG-05:05 | 2933.74 | 16-AUG-16:30 | 2933.74 | 16-AUG-16:30 | 411.59 | 05-AUG-16:02 | 872.21 | 16-AUG-16:07 | 0.00 | 01-AUG-00:10 |
| September | 0.243554E+10 | 0.645527E+09 | 654.57 | 0.241662E+10 | 18921825.20 | 0.00 | 0.51 | 10-SEP-16:05 | 0.00 | 06-SEP-06:45 | 2751.26 | 10-SEP-16:05 | 2751.26 | 10-SEP-16:05 | 134.80 | 01-SEP-14:30 | 771.08 | 10-SEP-16:05 | 0.00 | 01-SEP-00:10 |
| October | 0.797272E+09 | 0.208780E+09 | 276.53 | 0.797235E+09 | 37220.75 | 0.00 | 0.45 | 11-OCT-15:10 | 0.00 | 01-OCT-00:40 | 2566.08 | 11-OCT-15:10 | 2566.08 | 11-OCT-15:10 | 5.68 | 09-OCT-09:15 | 663.03 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.165232E+09 | 43699324.18 | 87.26 | 0.165232E+09 | -0.0 | 0.00 | 0.29 | 07-NOV-15:10 | 0.00 | 01-NOV-00:10 | 1592.07 | 07-NOV-15:10 | 1592.07 | 07-NOV-15:10 | 0.00 | 08-NOV-15:50 | 412.16 | 07-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 16450927.85 | 4412360.08 | 20.50 | 16450927.85 | -0.0 | 0.00 | 0.10 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 544.05 | 02-DEC-15:00 | 544.05 | 02-DEC-15:00 | 0.00 | 02-DEC-15:00 | 144.93 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.111806E+11 | 0.300231E+10 | 3348.44 | 0.108472E+11 | 0.333496E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 1350547.03 | 363608.50 | 3.00 | 1350547.03 | -0.0 | 0.00 | 0.05 | 0.00 | 270.76 | 270.76 | 0.00 | 72.68 | 0.00 | |||||||
| Maximum of Months | 0.278847E+10 | 0.747067E+09 | 727.53 | 0.266941E+10 | 0.121621E+09 | 0.00 | 0.56 | 0.00 | 2933.74 | 2933.74 | 411.59 | 872.21 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 74786014.99 | 20353184.74 | 63.35 | 74649458.20 | 136556.79 | 0.00 | 0.18 | 31-MAY-17:30 | 0.00 | 01-MAY-00:10 | 953.51 | 31-MAY-17:30 | 953.51 | 31-MAY-17:30 | 17.06 | 31-MAY-19:00 | 257.64 | 31-MAY-17:20 | 0.00 | 01-MAY-00:10 |
| June | 0.203673E+10 | 0.556497E+09 | 648.02 | 0.196855E+10 | 68181858.02 | 0.00 | 0.55 | 26-JUN-17:30 | 0.00 | 01-JUN-00:10 | 2675.24 | 26-JUN-17:23 | 2675.24 | 26-JUN-17:23 | 271.43 | 18-JUN-12:00 | 811.74 | 26-JUN-17:23 | 0.00 | 01-JUN-00:10 |
| July | 0.224257E+10 | 0.608860E+09 | 704.04 | 0.213343E+10 | 0.109133E+09 | 0.00 | 0.47 | 15-JUL-17:30 | 0.00 | 02-JUL-03:30 | 2338.40 | 15-JUL-17:40 | 2338.40 | 15-JUL-17:40 | 332.25 | 30-JUL-16:00 | 675.48 | 15-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.215092E+10 | 0.579927E+09 | 713.48 | 0.205158E+10 | 99341333.28 | 0.00 | 0.51 | 16-AUG-16:40 | 0.00 | 01-AUG-05:05 | 2526.42 | 16-AUG-17:00 | 2526.42 | 16-AUG-17:00 | 369.10 | 05-AUG-16:15 | 752.35 | 16-AUG-16:40 | 0.00 | 01-AUG-00:10 |
| September | 0.148582E+10 | 0.398793E+09 | 564.81 | 0.147326E+10 | 12564513.91 | 0.00 | 0.42 | 10-SEP-16:30 | 0.00 | 01-SEP-07:35 | 2119.21 | 10-SEP-16:30 | 2119.21 | 10-SEP-16:30 | 86.60 | 01-SEP-14:40 | 598.46 | 10-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 75557631.10 | 20230193.21 | 59.71 | 75557631.10 | 0.00 | 0.00 | 0.22 | 11-OCT-16:10 | 0.00 | 01-OCT-00:10 | 1144.28 | 11-OCT-16:10 | 1144.28 | 11-OCT-16:10 | 0.00 | 09-OCT-16:03 | 300.44 | 11-OCT-15:20 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.806638E+10 | 0.218466E+10 | 2753.41 | 0.777703E+10 | 0.289357E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.224257E+10 | 0.608860E+09 | 713.48 | 0.213343E+10 | 0.109133E+09 | 0.00 | 0.55 | 0.00 | 2675.24 | 2675.24 | 369.10 | 811.74 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.105329E+09 | 27901647.53 | 44.00 | 0.105329E+09 | -0.0 | 0.00 | 0.20 | 24-JAN-14:00 | 0.00 | 01-JAN-00:10 | 1197.70 | 24-JAN-14:00 | 1197.70 | 24-JAN-14:00 | 0.00 | 20-JAN-11:00 | 314.26 | 24-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 19991017.91 | 5328481.76 | 14.33 | 19991017.91 | 0.00 | 0.00 | 0.14 | 27-FEB-12:00 | 0.00 | 01-FEB-00:10 | 824.37 | 27-FEB-12:00 | 824.37 | 27-FEB-12:00 | 0.00 | 17-FEB-13:20 | 218.34 | 27-FEB-12:00 | 0.00 | 01-FEB-00:10 |
| March | 0.239475E+09 | 62273382.39 | 63.31 | 0.239410E+09 | 65251.10 | 0.00 | 0.77 | 15-MAR-08:62 | 0.00 | 01-MAR-00:10 | 5120.17 | 15-MAR-08:62 | 5120.17 | 15-MAR-08:62 | 7.88 | 17-MAR-13:30 | 1223.92 | 15-MAR-08:62 | 0.00 | 01-MAR-00:10 |
| April | 96619528.79 | 25687782.84 | 52.83 | 96560502.00 | 59026.80 | 0.00 | 0.16 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 984.75 | 20-APR-13:00 | 984.75 | 20-APR-13:00 | 10.62 | 28-APR-14:30 | 259.77 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
| May | 0.575709E+09 | 0.151348E+09 | 152.39 | 0.567592E+09 | 8117448.26 | 0.00 | 0.93 | 17-MAY-08:62 | 0.00 | 01-MAY-00:10 | 6458.23 | 17-MAY-08:62 | 6458.23 | 17-MAY-08:62 | 488.22 | 22-MAY-08:63 | 1488.25 | 17-MAY-08:62 | 0.00 | 01-MAY-00:10 |
| June | 0.214039E+10 | 0.568763E+09 | 229.11 | 0.208411E+10 | 56281019.81 | 0.00 | 1.00 | 05-JUN-08:62 | 0.00 | 01-JUN-00:10 | 7707.03 | 21-JUN-07:02 | 7364.49 | 19-JUN-07:02 | 1715.13 | 21-JUN-08:62 | 1672.66 | 13-JUN-07:02 | 0.00 | 01-JUN-00:10 |
| July | 0.215718E+10 | 0.565892E+09 | 260.40 | 0.207320E+10 | 83985843.68 | 0.00 | 1.00 | 03-JUL-07:01 | 0.00 | 01-JUL-00:10 | 7692.47 | 31-JUL-07:02 | 7319.10 | 19-JUL-07:02 | 1996.10 | 28-JUL-08:62 | 1678.61 | 24-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.254287E+10 | 0.662240E+09 | 268.92 | 0.246529E+10 | 77579041.86 | 0.00 | 1.00 | 03-AUG-07:02 | 0.00 | 01-AUG-00:10 | 7907.69 | 04-AUG-07:02 | 7347.88 | 07-AUG-07:02 | 2205.45 | 04-AUG-07:02 | 1666.14 | 04-AUG-07:02 | 0.00 | 01-AUG-00:10 |
| September | 0.208602E+10 | 0.534906E+09 | 239.65 | 0.207391E+10 | 12113329.57 | 0.00 | 1.00 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 | 7354.97 | 01-SEP-07:01 | 7263.87 | 13-SEP-07:02 | 725.70 | 01-SEP-08:62 | 1637.45 | 01-SEP-07:01 | 0.00 | 01-SEP-00:10 |
| October | 0.792741E+09 | 0.203189E+09 | 122.11 | 0.792635E+09 | 105516.05 | 0.00 | 1.00 | 10-OCT-08:62 | 0.00 | 01-OCT-00:10 | 6937.49 | 10-OCT-08:62 | 6937.49 | 10-OCT-08:62 | 29.24 | 03-OCT-11:00 | 1589.13 | 10-OCT-08:62 | 0.00 | 01-OCT-00:10 |
| November | 0.303226E+09 | 78775373.19 | 70.01 | 0.303226E+09 | 0.00 | 0.00 | 0.90 | 07-NOV-09:02 | 0.00 | 01-NOV-00:10 | 6112.23 | 07-NOV-09:02 | 6112.23 | 07-NOV-09:02 | 0.00 | 09-NOV-10:00 | 1428.90 | 07-NOV-09:02 | 0.00 | 01-NOV-00:10 |
| December | 40900845.92 | 10887077.93 | 24.83 | 40900845.92 | 0.00 | 0.00 | 0.18 | 04-DEC-14:00 | 0.00 | 01-DEC-00:10 | 1072.74 | 04-DEC-14:00 | 1072.74 | 04-DEC-14:00 | 0.00 | 04-DEC-11:00 | 282.35 | 04-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.111005E+11 | 0.289719E+10 | 1541.88 | 0.108621E+11 | 0.238306E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 19991017.91 | 5328481.76 | 14.33 | 19991017.91 | -0.0 | 0.00 | 0.14 | 0.00 | 824.37 | 824.37 | 0.00 | 218.34 | 0.00 | |||||||
| Maximum of Months | 0.254287E+10 | 0.662240E+09 | 268.92 | 0.246529E+10 | 83985843.68 | 0.00 | 1.00 | 0.00 | 7907.69 | 7364.49 | 2205.45 | 1678.61 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 90604427.26 | 24593032.21 | 80.58 | 90453886.85 | 150540.41 | 0.00 | 0.18 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 | 814.41 | 17-MAY-13:30 | 814.41 | 17-MAY-13:30 | 13.22 | 31-MAY-09:50 | 230.28 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 |
| June | 0.212652E+10 | 0.577273E+09 | 660.11 | 0.205148E+10 | 75039656.99 | 0.00 | 0.52 | 26-JUN-17:27 | 0.00 | 01-JUN-00:10 | 2218.62 | 26-JUN-17:27 | 2218.62 | 26-JUN-17:27 | 320.57 | 18-JUN-09:50 | 676.65 | 26-JUN-17:27 | 0.00 | 01-JUN-00:10 |
| July | 0.242130E+10 | 0.652723E+09 | 710.00 | 0.230335E+10 | 0.117941E+09 | 0.00 | 0.49 | 16-JUL-15:10 | 0.00 | 02-JUL-02:50 | 2145.28 | 16-JUL-15:10 | 2145.28 | 16-JUL-15:10 | 292.88 | 30-JUL-16:10 | 638.95 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.231471E+10 | 0.619450E+09 | 722.44 | 0.220242E+10 | 0.112296E+09 | 0.00 | 0.47 | 16-AUG-16:13 | 0.00 | 01-AUG-05:05 | 2047.30 | 16-AUG-17:06 | 2047.30 | 16-AUG-17:06 | 371.55 | 04-AUG-07:35 | 614.00 | 16-AUG-16:30 | 0.00 | 01-AUG-00:10 |
| September | 0.155641E+10 | 0.415902E+09 | 579.44 | 0.154256E+10 | 13854456.48 | 0.00 | 0.40 | 09-SEP-13:00 | 0.00 | 04-SEP-06:40 | 1800.21 | 09-SEP-15:10 | 1800.21 | 09-SEP-15:10 | 117.72 | 06-SEP-08:40 | 513.85 | 09-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 70954756.61 | 18991967.08 | 58.83 | 70954756.61 | 0.00 | 0.00 | 0.19 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 | 866.46 | 11-OCT-14:10 | 866.46 | 11-OCT-14:10 | 0.00 | 11-OCT-10:20 | 237.19 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.858050E+10 | 0.230893E+10 | 2811.41 | 0.826121E+10 | 0.319282E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.242130E+10 | 0.652723E+09 | 722.44 | 0.230335E+10 | 0.117941E+09 | 0.00 | 0.52 | 0.00 | 2218.62 | 2218.62 | 371.55 | 676.65 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 67712445.75 | 18403170.76 | 74.64 | 67546526.13 | 165919.61 | 0.00 | 0.15 | 17-MAY-14:10 | 0.00 | 01-MAY-00:10 | 622.58 | 17-MAY-16:05 | 622.58 | 17-MAY-16:05 | 12.32 | 31-MAY-19:00 | 173.17 | 17-MAY-13:50 | 0.00 | 01-MAY-00:10 |
| June | 0.173807E+10 | 0.473341E+09 | 673.18 | 0.166921E+10 | 68858781.59 | 0.00 | 0.48 | 26-JUN-18:00 | 0.00 | 01-JUN-00:10 | 1867.44 | 26-JUN-18:00 | 1867.44 | 26-JUN-18:00 | 244.23 | 18-JUN-12:00 | 573.13 | 26-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.203485E+10 | 0.549199E+09 | 734.12 | 0.191911E+10 | 0.115736E+09 | 0.00 | 0.43 | 16-JUL-15:10 | 0.00 | 03-JUL-03:40 | 1696.60 | 16-JUL-15:10 | 1696.60 | 16-JUL-15:10 | 278.00 | 29-JUL-18:00 | 510.44 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.185593E+10 | 0.498535E+09 | 731.29 | 0.175594E+10 | 99991132.50 | 0.00 | 0.42 | 16-AUG-16:50 | 0.00 | 01-AUG-05:05 | 1683.47 | 16-AUG-17:06 | 1683.47 | 16-AUG-17:06 | 278.34 | 05-AUG-16:02 | 505.94 | 16-AUG-16:50 | 0.00 | 01-AUG-00:10 |
| September | 0.125827E+10 | 0.337445E+09 | 593.26 | 0.124573E+10 | 12539209.07 | 0.00 | 0.36 | 10-SEP-16:03 | 0.00 | 01-SEP-07:35 | 1455.60 | 10-SEP-16:03 | 1455.60 | 10-SEP-16:03 | 77.74 | 06-SEP-08:40 | 418.01 | 10-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 49498973.70 | 13290322.57 | 52.50 | 49498973.70 | -0.0 | 0.00 | 0.17 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 697.53 | 11-OCT-15:10 | 697.53 | 11-OCT-15:10 | 0.00 | 11-OCT-15:50 | 188.52 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.700432E+10 | 0.189021E+10 | 2859.00 | 0.670703E+10 | 0.297291E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.203485E+10 | 0.549199E+09 | 734.12 | 0.191911E+10 | 0.115736E+09 | 0.00 | 0.48 | 0.00 | 1867.44 | 1867.44 | 278.34 | 573.13 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 70564174.20 | 19168574.57 | 77.52 | 70392642.56 | 171531.63 | 0.00 | 0.15 | 17-MAY-13:50 | 0.00 | 01-MAY-00:10 | 633.00 | 17-MAY-16:05 | 633.00 | 17-MAY-16:05 | 12.19 | 31-MAY-19:00 | 176.81 | 17-MAY-13:50 | 0.00 | 01-MAY-00:10 |
| June | 0.174361E+10 | 0.474757E+09 | 673.74 | 0.167447E+10 | 69142264.22 | 0.00 | 0.48 | 26-JUN-18:00 | 0.00 | 01-JUN-00:10 | 1858.86 | 26-JUN-18:00 | 1858.86 | 26-JUN-18:00 | 245.17 | 18-JUN-10:10 | 570.56 | 26-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.204404E+10 | 0.551546E+09 | 733.70 | 0.192781E+10 | 0.116225E+09 | 0.00 | 0.43 | 16-JUL-15:10 | 0.00 | 02-JUL-04:40 | 1698.77 | 16-JUL-15:10 | 1698.77 | 16-JUL-15:10 | 277.79 | 29-JUL-18:00 | 510.95 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.186490E+10 | 0.500815E+09 | 732.89 | 0.176433E+10 | 0.100572E+09 | 0.00 | 0.42 | 16-AUG-16:50 | 0.00 | 01-AUG-05:05 | 1673.09 | 16-AUG-17:06 | 1673.09 | 16-AUG-17:06 | 279.08 | 05-AUG-16:02 | 503.09 | 16-AUG-16:50 | 0.00 | 01-AUG-00:10 |
| September | 0.126329E+10 | 0.338742E+09 | 593.39 | 0.125070E+10 | 12591571.77 | 0.00 | 0.36 | 10-SEP-16:03 | 0.00 | 01-SEP-07:35 | 1451.34 | 10-SEP-16:03 | 1451.34 | 10-SEP-16:03 | 78.65 | 06-SEP-08:40 | 416.79 | 10-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 50043925.55 | 13435352.56 | 53.17 | 50043041.02 | 884.52 | 0.00 | 0.17 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 695.73 | 11-OCT-15:10 | 695.73 | 11-OCT-15:10 | 1.47 | 01-OCT-00:20 | 188.03 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.703645E+10 | 0.189846E+10 | 2864.40 | 0.673775E+10 | 0.298704E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.204404E+10 | 0.551546E+09 | 733.70 | 0.192781E+10 | 0.116225E+09 | 0.00 | 0.48 | 0.00 | 1858.86 | 1858.86 | 279.08 | 570.56 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 37914866.68 | 10122526.24 | 37.42 | 37914866.68 | -0.0 | 0.00 | 0.13 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 564.13 | 20-JAN-14:00 | 564.13 | 20-JAN-14:00 | 0.00 | 20-JAN-13:30 | 149.69 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 9701793.28 | 2604271.88 | 18.11 | 9701793.28 | 0.00 | 0.00 | 0.08 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 | 361.70 | 18-FEB-14:00 | 361.70 | 18-FEB-14:00 | 0.00 | 18-FEB-13:20 | 96.63 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.129208E+09 | 34137274.07 | 78.29 | 0.129208E+09 | 0.00 | 0.00 | 0.26 | 14-MAR-13:10 | 0.00 | 01-MAR-00:10 | 1203.55 | 14-MAR-13:10 | 1203.55 | 14-MAR-13:10 | 0.00 | 13-MAR-14:20 | 312.88 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 0.176156E+09 | 47421816.53 | 161.94 | 0.175622E+09 | 534316.94 | 0.00 | 0.19 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 | 839.57 | 17-MAY-13:30 | 839.57 | 17-MAY-13:30 | 17.64 | 21-MAY-20:00 | 237.04 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 |
| June | 0.191983E+10 | 0.522472E+09 | 680.09 | 0.184428E+10 | 75548662.34 | 0.00 | 0.46 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 | 1905.78 | 26-JUN-17:03 | 1905.78 | 26-JUN-17:03 | 305.37 | 18-JUN-10:10 | 593.48 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.228700E+10 | 0.616361E+09 | 734.55 | 0.215797E+10 | 0.129033E+09 | 0.00 | 0.43 | 16-JUL-15:10 | 0.00 | 02-JUL-07:12 | 1814.26 | 16-JUL-15:10 | 1814.26 | 16-JUL-15:10 | 338.07 | 30-JUL-16:10 | 545.73 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.251908E+10 | 0.672091E+09 | 740.33 | 0.239782E+10 | 0.121261E+09 | 0.00 | 0.51 | 16-AUG-14:00 | 0.00 | 01-AUG-05:15 | 2135.86 | 16-AUG-14:10 | 2135.86 | 16-AUG-14:10 | 325.99 | 05-AUG-16:02 | 645.95 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.225676E+10 | 0.596417E+09 | 672.97 | 0.223743E+10 | 19322363.48 | 0.00 | 0.49 | 28-SEP-14:00 | 0.00 | 16-SEP-03:30 | 2195.12 | 28-SEP-14:10 | 2195.12 | 28-SEP-14:10 | 111.63 | 01-SEP-14:30 | 604.04 | 28-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.844015E+09 | 0.220661E+09 | 333.89 | 0.843903E+09 | 112235.95 | 0.00 | 0.46 | 11-OCT-14:10 | 0.00 | 01-OCT-04:00 | 2130.47 | 11-OCT-14:10 | 2130.47 | 11-OCT-14:10 | 16.26 | 01-OCT-00:10 | 558.99 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.221588E+09 | 58448113.40 | 127.17 | 0.221588E+09 | 0.00 | 0.00 | 0.31 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 | 1432.22 | 07-NOV-14:00 | 1432.22 | 07-NOV-14:00 | 0.00 | 07-NOV-12:30 | 369.31 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 28592932.00 | 7651679.04 | 36.11 | 28592932.00 | 0.00 | 0.00 | 0.11 | 17-DEC-14:30 | 0.00 | 01-DEC-00:10 | 494.69 | 17-DEC-14:30 | 494.69 | 17-DEC-14:30 | 0.00 | 02-DEC-13:10 | 131.57 | 17-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.104298E+11 | 0.278839E+10 | 3620.87 | 0.100840E+11 | 0.345811E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.251908E+10 | 0.672091E+09 | 740.33 | 0.239782E+10 | 0.129033E+09 | 0.00 | 0.51 | 0.00 | 2195.12 | 2195.12 | 338.07 | 645.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 38967454.89 | 10403379.20 | 38.42 | 38967454.89 | 0.00 | 0.00 | 0.12 | 25-JAN-14:00 | 0.00 | 01-JAN-00:10 | 561.10 | 25-JAN-14:00 | 561.10 | 25-JAN-14:00 | 0.00 | 24-JAN-15:50 | 148.92 | 25-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 9975550.57 | 2677763.01 | 18.28 | 9975550.57 | -0.0 | 0.00 | 0.08 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 | 343.08 | 18-FEB-14:00 | 343.08 | 18-FEB-14:00 | 0.00 | 18-FEB-14:50 | 91.72 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.140631E+09 | 37126791.37 | 81.82 | 0.140631E+09 | 0.00 | 0.00 | 0.27 | 14-MAR-13:10 | 0.00 | 01-MAR-00:10 | 1258.92 | 14-MAR-13:10 | 1258.92 | 14-MAR-13:10 | 0.00 | 13-MAR-16:12 | 326.60 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 0.210819E+09 | 56624409.86 | 188.29 | 0.210117E+09 | 701782.70 | 0.00 | 0.20 | 17-MAY-13:40 | 0.00 | 01-MAY-00:10 | 900.16 | 17-MAY-13:40 | 900.16 | 17-MAY-13:40 | 20.52 | 21-MAY-20:00 | 253.67 | 17-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.212599E+10 | 0.576281E+09 | 693.84 | 0.204201E+10 | 83985525.77 | 0.00 | 0.48 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 | 2001.47 | 26-JUN-17:17 | 2001.47 | 26-JUN-17:17 | 320.58 | 18-JUN-10:10 | 621.71 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.255855E+10 | 0.686684E+09 | 742.01 | 0.241671E+10 | 0.141836E+09 | 0.00 | 0.46 | 16-JUL-15:10 | 0.00 | 04-JUL-04:00 | 1971.08 | 23-JUL-14:00 | 1971.08 | 23-JUL-14:00 | 360.97 | 30-JUL-16:10 | 589.35 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.278676E+10 | 0.740582E+09 | 743.48 | 0.265280E+10 | 0.133965E+09 | 0.00 | 0.53 | 16-AUG-14:00 | 0.00 | 01-AUG-05:50 | 2215.94 | 16-AUG-14:00 | 2215.94 | 16-AUG-14:00 | 345.75 | 05-AUG-16:02 | 668.74 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.248591E+10 | 0.654958E+09 | 680.20 | 0.246469E+10 | 21226211.60 | 0.00 | 0.51 | 10-SEP-14:10 | 0.00 | 21-SEP-15:00 | 2290.43 | 10-SEP-14:10 | 2290.43 | 10-SEP-14:10 | 116.47 | 01-SEP-14:30 | 646.49 | 10-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.926299E+09 | 0.241861E+09 | 352.56 | 0.926164E+09 | 135073.43 | 0.00 | 0.47 | 11-OCT-14:10 | 0.00 | 02-OCT-00:10 | 2201.16 | 11-OCT-14:10 | 2201.16 | 11-OCT-14:10 | 21.55 | 01-OCT-00:10 | 576.48 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.229405E+09 | 60500781.92 | 130.66 | 0.229405E+09 | -0.0 | 0.00 | 0.31 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 | 1446.26 | 07-NOV-14:00 | 1446.26 | 07-NOV-14:00 | 0.00 | 08-NOV-17:04 | 372.88 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 26575245.70 | 7114134.27 | 33.71 | 26575245.70 | -0.0 | 0.00 | 0.11 | 17-DEC-14:30 | 0.00 | 01-DEC-00:10 | 485.59 | 17-DEC-14:30 | 485.59 | 17-DEC-14:30 | 0.00 | 02-DEC-12:50 | 129.21 | 17-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.115399E+11 | 0.307481E+10 | 3703.26 | 0.111580E+11 | 0.381849E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.278676E+10 | 0.740582E+09 | 743.48 | 0.265280E+10 | 0.141836E+09 | 0.00 | 0.53 | 0.00 | 2290.43 | 2290.43 | 360.97 | 668.74 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.477083E+09 | 0.126105E+09 | 104.92 | 0.477083E+09 | 0.00 | 0.00 | 0.28 | 20-JAN-15:10 | 0.00 | 01-JAN-00:10 | 4036.10 | 20-JAN-15:10 | 4036.10 | 20-JAN-15:10 | 0.00 | 20-JAN-14:50 | 1044.97 | 20-JAN-15:10 | 0.00 | 01-JAN-00:10 |
| February | 0.352255E+09 | 93403272.02 | 82.83 | 0.352255E+09 | -0.0 | 0.00 | 0.25 | 18-FEB-14:30 | 0.00 | 01-FEB-00:10 | 3527.94 | 18-FEB-14:30 | 3527.94 | 18-FEB-14:30 | 0.00 | 18-FEB-13:20 | 918.34 | 18-FEB-14:30 | 0.00 | 01-FEB-00:10 |
| March | 0.111507E+10 | 0.292334E+09 | 166.58 | 0.111507E+10 | 0.00 | 0.00 | 0.39 | 13-MAR-16:07 | 0.00 | 01-MAR-00:10 | 5672.95 | 13-MAR-16:07 | 5672.95 | 13-MAR-16:07 | 0.00 | 15-MAR-14:40 | 1443.75 | 13-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.400077E+09 | 0.106335E+09 | 108.50 | 0.400064E+09 | 12432.76 | 0.00 | 0.24 | 08-APR-17:13 | 0.00 | 01-APR-00:10 | 3433.09 | 08-APR-17:13 | 3433.09 | 08-APR-17:13 | 13.30 | 28-APR-16:04 | 894.55 | 08-APR-17:13 | 0.00 | 01-APR-00:10 |
| May | 0.218790E+10 | 0.578739E+09 | 422.59 | 0.217065E+10 | 17250365.93 | 0.00 | 0.34 | 31-MAY-16:15 | 0.00 | 01-MAY-00:10 | 4908.42 | 31-MAY-16:25 | 4908.42 | 31-MAY-16:25 | 121.24 | 31-MAY-21:05 | 1316.24 | 31-MAY-16:15 | 0.00 | 01-MAY-00:10 |
| June | 0.663232E+10 | 0.179693E+10 | 710.02 | 0.639766E+10 | 0.234661E+09 | 0.00 | 0.54 | 26-JUN-17:03 | 0.00 | 03-JUN-05:35 | 6966.87 | 26-JUN-17:03 | 6966.87 | 26-JUN-17:03 | 786.02 | 18-JUN-10:00 | 2118.40 | 26-JUN-17:03 | 0.00 | 01-JUN-00:10 |
| July | 0.696868E+10 | 0.188038E+10 | 737.92 | 0.662138E+10 | 0.347295E+09 | 0.00 | 0.48 | 15-JUL-17:30 | 0.00 | 04-JUL-03:20 | 6376.67 | 15-JUL-17:30 | 6376.67 | 15-JUL-17:30 | 1167.90 | 30-JUL-16:10 | 1840.16 | 15-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.695224E+10 | 0.186436E+10 | 732.79 | 0.666843E+10 | 0.283816E+09 | 0.00 | 0.55 | 16-AUG-16:01 | 0.00 | 01-AUG-05:30 | 7192.11 | 16-AUG-16:30 | 7192.11 | 16-AUG-16:30 | 1066.81 | 05-AUG-15:50 | 2149.15 | 16-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.535407E+10 | 0.142481E+10 | 631.91 | 0.531616E+10 | 37908527.34 | 0.00 | 0.48 | 28-SEP-15:30 | 0.00 | 04-SEP-06:40 | 6668.34 | 28-SEP-15:30 | 6668.34 | 28-SEP-15:30 | 346.50 | 01-SEP-14:30 | 1830.98 | 10-SEP-16:08 | 0.00 | 01-SEP-00:10 |
| October | 0.207981E+10 | 0.544061E+09 | 275.33 | 0.207976E+10 | 46761.76 | 0.00 | 0.45 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 6452.15 | 11-OCT-15:10 | 6452.15 | 11-OCT-15:10 | 9.71 | 09-OCT-09:05 | 1668.31 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.817544E+09 | 0.215192E+09 | 141.56 | 0.817544E+09 | -0.0 | 0.00 | 0.35 | 07-NOV-15:00 | 0.00 | 01-NOV-00:10 | 5001.01 | 07-NOV-15:00 | 5001.01 | 07-NOV-15:00 | 0.00 | 08-NOV-13:30 | 1281.70 | 07-NOV-15:00 | 0.00 | 01-NOV-00:10 |
| December | 0.265542E+09 | 70495441.50 | 64.25 | 0.265542E+09 | 0.00 | 0.00 | 0.23 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 3204.34 | 02-DEC-15:00 | 3204.34 | 02-DEC-15:00 | 0.00 | 02-DEC-15:00 | 836.99 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.336026E+11 | 0.899314E+10 | 4179.20 | 0.326816E+11 | 0.920990E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.265542E+09 | 70495441.50 | 64.25 | 0.265542E+09 | -0.0 | 0.00 | 0.23 | 0.00 | 3204.34 | 3204.34 | 0.00 | 836.99 | 0.00 | |||||||
| Maximum of Months | 0.696868E+10 | 0.188038E+10 | 737.92 | 0.666843E+10 | 0.347295E+09 | 0.00 | 0.55 | 0.00 | 7192.11 | 7192.11 | 1167.90 | 2149.15 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.142501E+09 | 38000128.05 | 50.25 | 0.142501E+09 | 0.00 | 0.00 | 0.17 | 13-MAR-16:30 | 0.00 | 01-MAR-00:10 | 2308.54 | 13-MAR-16:30 | 2308.54 | 13-MAR-16:30 | 0.00 | 13-MAR-16:03 | 608.38 | 13-MAR-16:30 | 0.00 | 01-MAR-00:10 |
| April | 32386429.39 | 8688990.84 | 20.42 | 32386429.39 | 0.00 | 0.00 | 0.10 | 20-APR-17:15 | 0.00 | 01-APR-00:10 | 1309.27 | 20-APR-17:15 | 1309.27 | 20-APR-17:15 | 0.00 | 08-APR-17:20 | 348.90 | 20-APR-17:15 | 0.00 | 01-APR-00:10 |
| May | 0.165070E+10 | 0.438034E+09 | 386.66 | 0.163594E+10 | 14759925.47 | 0.00 | 0.33 | 31-MAY-17:20 | 0.00 | 01-MAY-00:10 | 4642.02 | 31-MAY-17:30 | 4642.02 | 31-MAY-17:30 | 130.38 | 22-MAY-16:30 | 1228.06 | 31-MAY-17:20 | 0.00 | 01-MAY-00:10 |
| June | 0.627949E+10 | 0.170200E+10 | 711.06 | 0.605141E+10 | 0.228078E+09 | 0.00 | 0.55 | 26-JUN-17:30 | 0.00 | 03-JUN-03:50 | 6908.73 | 26-JUN-17:27 | 6908.73 | 26-JUN-17:27 | 715.18 | 22-JUN-14:10 | 2096.97 | 26-JUN-17:27 | 0.00 | 01-JUN-00:10 |
| July | 0.644713E+10 | 0.174170E+10 | 738.69 | 0.611858E+10 | 0.328547E+09 | 0.00 | 0.47 | 15-JUL-17:30 | 0.00 | 04-JUL-02:50 | 6182.53 | 15-JUL-17:40 | 6182.53 | 15-JUL-17:40 | 1007.43 | 30-JUL-16:10 | 1783.44 | 15-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.557572E+10 | 0.150308E+10 | 726.38 | 0.532361E+10 | 0.252115E+09 | 0.00 | 0.49 | 16-AUG-16:30 | 0.00 | 01-AUG-05:05 | 6269.91 | 16-AUG-16:30 | 6269.91 | 16-AUG-16:30 | 956.43 | 05-AUG-15:50 | 1885.06 | 16-AUG-16:30 | 0.00 | 01-AUG-00:10 |
| September | 0.333165E+10 | 0.897902E+09 | 557.15 | 0.330466E+10 | 26984485.02 | 0.00 | 0.38 | 10-SEP-16:30 | 0.00 | 04-SEP-06:40 | 5041.54 | 10-SEP-16:30 | 5041.54 | 10-SEP-16:30 | 232.69 | 01-SEP-14:40 | 1429.93 | 10-SEP-16:30 | 0.00 | 01-SEP-00:10 |
| October | 0.260453E+09 | 69605544.34 | 80.49 | 0.260453E+09 | 0.00 | 0.00 | 0.24 | 11-OCT-15:30 | 0.00 | 01-OCT-00:10 | 3195.20 | 11-OCT-15:30 | 3195.20 | 11-OCT-15:30 | 0.00 | 09-OCT-16:20 | 846.54 | 11-OCT-15:30 | 0.00 | 01-OCT-00:10 |
| November | 1475354.91 | 397880.83 | 2.33 | 1475354.91 | 0.00 | 0.00 | 0.02 | 07-NOV-15:40 | 0.00 | 01-NOV-00:10 | 325.68 | 07-NOV-15:40 | 325.68 | 07-NOV-15:40 | 0.00 | 07-NOV-15:30 | 87.76 | 07-NOV-15:40 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.237215E+11 | 0.639941E+10 | 3273.43 | 0.228710E+11 | 0.850484E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.644713E+10 | 0.174170E+10 | 738.69 | 0.611858E+10 | 0.328547E+09 | 0.00 | 0.55 | 0.00 | 6908.73 | 6908.73 | 1007.43 | 2096.97 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.438315E+09 | 0.115817E+09 | 100.67 | 0.438315E+09 | -0.0 | 0.00 | 0.30 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 3721.26 | 20-JAN-14:00 | 3721.26 | 20-JAN-14:00 | 0.00 | 20-JAN-13:30 | 961.32 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.363748E+09 | 96231289.86 | 89.92 | 0.363748E+09 | -0.0 | 0.00 | 0.28 | 18-FEB-13:30 | 0.00 | 01-FEB-00:10 | 3422.59 | 18-FEB-13:30 | 3422.59 | 18-FEB-13:30 | 0.00 | 18-FEB-13:20 | 887.36 | 18-FEB-13:30 | 0.00 | 01-FEB-00:10 |
| March | 0.112596E+10 | 0.294226E+09 | 171.82 | 0.112596E+10 | -0.0 | 0.00 | 0.40 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 5096.21 | 14-MAR-13:00 | 5096.21 | 14-MAR-13:00 | 0.00 | 11-MAR-10:50 | 1297.00 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.468956E+09 | 0.124374E+09 | 127.46 | 0.468947E+09 | 9213.28 | 0.00 | 0.23 | 21-APR-12:40 | 0.00 | 01-APR-00:10 | 2869.36 | 21-APR-12:40 | 2869.36 | 21-APR-12:40 | 7.88 | 28-APR-16:07 | 748.93 | 21-APR-12:40 | 0.00 | 01-APR-00:10 |
| May | 0.233590E+10 | 0.616332E+09 | 455.41 | 0.231809E+10 | 17814194.11 | 0.00 | 0.34 | 16-MAY-13:30 | 0.00 | 01-MAY-00:10 | 4184.17 | 16-MAY-13:30 | 4184.17 | 16-MAY-13:30 | 179.45 | 31-MAY-08:50 | 1128.54 | 16-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.683763E+10 | 0.183974E+10 | 711.62 | 0.658771E+10 | 0.249920E+09 | 0.00 | 0.51 | 26-JUN-15:10 | 0.00 | 03-JUN-05:35 | 5730.56 | 30-JUN-14:00 | 5730.56 | 30-JUN-14:00 | 940.24 | 18-JUN-09:30 | 1788.23 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.735711E+10 | 0.197119E+10 | 737.01 | 0.699589E+10 | 0.361224E+09 | 0.00 | 0.49 | 16-JUL-14:30 | 0.00 | 02-JUL-04:30 | 5747.87 | 18-JUL-13:00 | 5747.87 | 18-JUL-13:00 | 1050.09 | 30-JUL-16:10 | 1689.00 | 18-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.730706E+10 | 0.194396E+10 | 738.39 | 0.699802E+10 | 0.309045E+09 | 0.00 | 0.55 | 16-AUG-14:00 | 0.00 | 01-AUG-05:30 | 6293.75 | 16-AUG-13:20 | 6293.75 | 16-AUG-13:20 | 960.16 | 05-AUG-15:40 | 1886.24 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.552478E+10 | 0.146178E+10 | 635.06 | 0.548424E+10 | 40540395.44 | 0.00 | 0.50 | 28-SEP-13:40 | 0.00 | 04-SEP-06:40 | 6118.10 | 28-SEP-13:40 | 6118.10 | 28-SEP-13:40 | 339.95 | 01-SEP-09:30 | 1693.58 | 09-SEP-12:40 | 0.00 | 01-SEP-00:10 |
| October | 0.201451E+10 | 0.526208E+09 | 283.74 | 0.201443E+10 | 80237.81 | 0.00 | 0.46 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 | 5693.95 | 11-OCT-13:50 | 5693.95 | 11-OCT-13:50 | 16.04 | 09-OCT-09:05 | 1498.26 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.791972E+09 | 0.208020E+09 | 143.09 | 0.791972E+09 | 0.00 | 0.00 | 0.35 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 | 4403.72 | 07-NOV-14:00 | 4403.72 | 07-NOV-14:00 | 0.00 | 08-NOV-14:40 | 1128.35 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.231722E+09 | 61589240.66 | 65.98 | 0.231722E+09 | -0.0 | 0.00 | 0.20 | 02-DEC-14:30 | 0.00 | 01-DEC-00:10 | 2465.26 | 02-DEC-14:30 | 2465.26 | 02-DEC-14:30 | 0.00 | 02-DEC-14:30 | 646.64 | 02-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.347977E+11 | 0.925947E+10 | 4260.18 | 0.338190E+11 | 0.978632E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.231722E+09 | 61589240.66 | 65.98 | 0.231722E+09 | -0.0 | 0.00 | 0.20 | 0.00 | 2465.26 | 2465.26 | 0.00 | 646.64 | 0.00 | |||||||
| Maximum of Months | 0.735711E+10 | 0.197119E+10 | 738.39 | 0.699802E+10 | 0.361224E+09 | 0.00 | 0.55 | 0.00 | 6293.75 | 6293.75 | 1050.09 | 1886.24 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.145067E+09 | 38693884.00 | 54.42 | 0.145067E+09 | 0.00 | 0.00 | 0.14 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 | 1662.84 | 14-MAR-16:07 | 1662.84 | 14-MAR-16:07 | 0.00 | 13-MAR-17:05 | 440.19 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 62345955.45 | 16682354.62 | 28.50 | 62345955.45 | 0.00 | 0.00 | 0.10 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 1179.34 | 20-APR-13:00 | 1179.34 | 20-APR-13:00 | 0.00 | 21-APR-11:00 | 314.14 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
| May | 0.178500E+10 | 0.472824E+09 | 430.32 | 0.176968E+10 | 15322356.44 | 0.00 | 0.30 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 | 3540.68 | 17-MAY-13:30 | 3540.68 | 17-MAY-13:30 | 186.56 | 31-MAY-08:50 | 982.34 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 |
| June | 0.648568E+10 | 0.174564E+10 | 711.74 | 0.624261E+10 | 0.243071E+09 | 0.00 | 0.50 | 26-JUN-17:30 | 0.00 | 03-JUN-03:50 | 5453.60 | 26-JUN-17:30 | 5453.60 | 26-JUN-17:30 | 834.23 | 18-JUN-09:20 | 1668.53 | 26-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.683648E+10 | 0.183408E+10 | 736.21 | 0.649315E+10 | 0.343333E+09 | 0.00 | 0.48 | 16-JUL-14:40 | 0.00 | 02-JUL-04:20 | 5373.63 | 16-JUL-14:30 | 5373.63 | 16-JUL-14:30 | 880.19 | 30-JUL-16:10 | 1597.36 | 16-JUL-14:40 | 0.00 | 01-JUL-00:10 |
| August | 0.592959E+10 | 0.158658E+10 | 730.68 | 0.564991E+10 | 0.279685E+09 | 0.00 | 0.44 | 16-AUG-16:13 | 0.00 | 01-AUG-05:05 | 4826.23 | 16-AUG-16:30 | 4826.23 | 16-AUG-16:30 | 934.24 | 04-AUG-07:35 | 1466.88 | 16-AUG-16:13 | 0.00 | 01-AUG-00:10 |
| September | 0.347695E+10 | 0.933206E+09 | 577.96 | 0.344689E+10 | 30060551.90 | 0.00 | 0.35 | 09-SEP-13:30 | 0.00 | 04-SEP-06:40 | 4027.74 | 09-SEP-15:00 | 4027.74 | 09-SEP-15:00 | 273.97 | 01-SEP-09:10 | 1146.29 | 09-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.232939E+09 | 62276581.51 | 74.14 | 0.232939E+09 | -0.0 | 0.00 | 0.20 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 | 2274.75 | 11-OCT-14:10 | 2274.75 | 11-OCT-14:10 | 0.00 | 09-OCT-16:03 | 622.27 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 539895.96 | 145836.51 | 1.67 | 539895.96 | 0.00 | 0.00 | 0.01 | 09-NOV-14:00 | 0.00 | 01-NOV-00:10 | 110.04 | 09-NOV-14:00 | 110.04 | 09-NOV-14:00 | 0.00 | 09-NOV-13:30 | 29.72 | 09-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.249546E+11 | 0.669014E+10 | 3345.63 | 0.240431E+11 | 0.911472E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.683648E+10 | 0.183408E+10 | 736.21 | 0.649315E+10 | 0.343333E+09 | 0.00 | 0.50 | 0.00 | 5453.60 | 5453.60 | 934.24 | 1668.53 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 85617171.77 | 22930327.39 | 46.33 | 85617171.77 | -0.0 | 0.00 | 0.11 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 | 1180.29 | 14-MAR-16:07 | 1180.29 | 14-MAR-16:07 | 0.00 | 16-MAR-18:50 | 313.84 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 10432162.01 | 2810286.45 | 13.50 | 10432162.01 | -0.0 | 0.00 | 0.05 | 20-APR-20:00 | 0.00 | 01-APR-00:10 | 538.00 | 20-APR-20:00 | 538.00 | 20-APR-20:00 | 0.00 | 20-APR-15:50 | 144.23 | 20-APR-20:00 | 0.00 | 01-APR-00:10 |
| May | 0.142446E+10 | 0.378184E+09 | 461.63 | 0.140639E+10 | 18075097.98 | 0.00 | 0.25 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 | 2786.46 | 31-MAY-18:00 | 2784.09 | 31-MAY-18:00 | 118.29 | 31-MAY-08:50 | 738.68 | 31-MAY-17:40 | 0.00 | 01-MAY-00:10 |
| June | 0.495180E+10 | 0.134010E+10 | 716.82 | 0.474348E+10 | 0.208317E+09 | 0.00 | 0.45 | 26-JUN-18:00 | 0.00 | 03-JUN-05:35 | 4427.88 | 26-JUN-18:00 | 4427.88 | 26-JUN-18:00 | 597.73 | 18-JUN-09:50 | 1364.41 | 26-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.533531E+10 | 0.143633E+10 | 743.00 | 0.502869E+10 | 0.306615E+09 | 0.00 | 0.41 | 16-JUL-15:10 | 0.00 | 04-JUL-04:00 | 4018.38 | 16-JUL-15:10 | 4018.38 | 16-JUL-15:10 | 721.46 | 30-JUL-16:10 | 1213.44 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.453404E+10 | 0.121862E+10 | 739.31 | 0.429421E+10 | 0.239828E+09 | 0.00 | 0.39 | 16-AUG-16:17 | 0.00 | 01-AUG-05:10 | 3804.57 | 16-AUG-17:04 | 3804.57 | 16-AUG-17:04 | 661.80 | 05-AUG-16:02 | 1160.02 | 16-AUG-16:17 | 0.00 | 01-AUG-00:10 |
| September | 0.276194E+10 | 0.743625E+09 | 598.30 | 0.273469E+10 | 27250539.48 | 0.00 | 0.30 | 10-SEP-16:05 | 0.00 | 04-SEP-06:40 | 3082.86 | 10-SEP-16:05 | 3082.86 | 10-SEP-16:05 | 159.64 | 06-SEP-08:40 | 892.82 | 10-SEP-16:05 | 0.00 | 01-SEP-00:10 |
| October | 0.171638E+09 | 46004267.52 | 71.70 | 0.171638E+09 | -0.0 | 0.00 | 0.18 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1854.38 | 11-OCT-15:10 | 1854.38 | 11-OCT-15:10 | 0.00 | 09-OCT-17:03 | 500.44 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 501537.86 | 135486.32 | 2.00 | 501537.86 | 0.00 | 0.00 | 0.01 | 09-NOV-14:00 | 0.00 | 01-NOV-00:10 | 106.83 | 09-NOV-14:00 | 106.83 | 09-NOV-14:00 | 0.00 | 09-NOV-13:30 | 28.85 | 09-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.192757E+11 | 0.518874E+10 | 3392.60 | 0.184757E+11 | 0.800086E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.533531E+10 | 0.143633E+10 | 743.00 | 0.502869E+10 | 0.306615E+09 | 0.00 | 0.45 | 0.00 | 4427.88 | 4427.88 | 721.46 | 1364.41 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 88491627.33 | 23695293.26 | 47.00 | 88491627.33 | -0.0 | 0.00 | 0.11 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 | 1200.53 | 14-MAR-16:07 | 1200.53 | 14-MAR-16:07 | 0.00 | 13-MAR-16:20 | 319.11 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 12740481.97 | 3430439.62 | 14.75 | 12740481.97 | -0.0 | 0.00 | 0.05 | 20-APR-20:00 | 0.00 | 01-APR-00:10 | 535.22 | 20-APR-20:00 | 535.22 | 20-APR-20:00 | 0.00 | 20-APR-16:03 | 143.49 | 20-APR-20:00 | 0.00 | 01-APR-00:10 |
| May | 0.143731E+10 | 0.381563E+09 | 464.44 | 0.141922E+10 | 18089076.65 | 0.00 | 0.25 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 | 2761.78 | 31-MAY-18:00 | 2759.42 | 31-MAY-18:00 | 119.74 | 31-MAY-08:50 | 732.59 | 17-MAY-13:30 | 0.00 | 01-MAY-00:10 |
| June | 0.496067E+10 | 0.134230E+10 | 716.65 | 0.475194E+10 | 0.208735E+09 | 0.00 | 0.45 | 26-JUN-18:00 | 0.00 | 03-JUN-05:35 | 4404.11 | 26-JUN-18:00 | 4404.11 | 26-JUN-18:00 | 601.39 | 18-JUN-09:50 | 1357.28 | 26-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.535040E+10 | 0.144015E+10 | 742.67 | 0.504321E+10 | 0.307189E+09 | 0.00 | 0.41 | 16-JUL-15:10 | 0.00 | 04-JUL-03:50 | 4024.02 | 16-JUL-15:10 | 4024.02 | 16-JUL-15:10 | 719.26 | 30-JUL-16:10 | 1214.80 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.454924E+10 | 0.122247E+10 | 739.68 | 0.430856E+10 | 0.240686E+09 | 0.00 | 0.39 | 16-AUG-16:17 | 0.00 | 01-AUG-05:15 | 3780.35 | 16-AUG-17:04 | 3780.35 | 16-AUG-17:04 | 662.15 | 05-AUG-16:02 | 1154.48 | 16-AUG-16:17 | 0.00 | 01-AUG-00:10 |
| September | 0.277182E+10 | 0.746199E+09 | 599.17 | 0.274451E+10 | 27316347.66 | 0.00 | 0.30 | 10-SEP-16:05 | 0.00 | 04-SEP-06:40 | 3066.05 | 10-SEP-16:05 | 3066.05 | 10-SEP-16:05 | 162.31 | 06-SEP-08:40 | 888.04 | 10-SEP-16:05 | 0.00 | 01-SEP-00:10 |
| October | 0.173126E+09 | 46398671.81 | 71.67 | 0.173125E+09 | 931.34 | 0.00 | 0.18 | 11-OCT-15:10 | 0.00 | 01-OCT-00:20 | 1849.64 | 11-OCT-15:10 | 1849.64 | 11-OCT-15:10 | 1.55 | 01-OCT-00:10 | 499.15 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 541173.81 | 146191.19 | 2.17 | 541173.81 | -0.0 | 0.00 | 0.01 | 09-NOV-14:00 | 0.00 | 01-NOV-00:10 | 110.06 | 09-NOV-14:00 | 110.06 | 09-NOV-14:00 | 0.00 | 09-NOV-13:40 | 29.72 | 09-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.193443E+11 | 0.520635E+10 | 3398.20 | 0.185423E+11 | 0.802016E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.535040E+10 | 0.144015E+10 | 742.67 | 0.504321E+10 | 0.307189E+09 | 0.00 | 0.45 | 0.00 | 4404.11 | 4404.11 | 719.26 | 1357.28 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.724715E+09 | 0.190972E+09 | 167.85 | 0.724715E+09 | 0.00 | 0.00 | 0.34 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 3923.47 | 20-JAN-14:00 | 3923.47 | 20-JAN-14:00 | 0.00 | 20-JAN-15:00 | 1006.29 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.512622E+09 | 0.135417E+09 | 124.08 | 0.512622E+09 | 0.00 | 0.00 | 0.30 | 18-FEB-13:30 | 0.00 | 01-FEB-00:10 | 3423.16 | 18-FEB-13:30 | 3423.16 | 18-FEB-13:30 | 0.00 | 17-FEB-15:00 | 883.80 | 18-FEB-13:30 | 0.00 | 01-FEB-00:10 |
| March | 0.105668E+10 | 0.276711E+09 | 191.24 | 0.105668E+10 | -0.0 | 0.00 | 0.39 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 4479.85 | 14-MAR-13:00 | 4479.85 | 14-MAR-13:00 | 0.00 | 11-MAR-13:10 | 1142.33 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.350894E+09 | 93364591.07 | 126.98 | 0.350829E+09 | 65457.72 | 0.00 | 0.20 | 21-APR-13:25 | 0.00 | 01-APR-00:10 | 2265.00 | 21-APR-13:25 | 2265.00 | 21-APR-13:25 | 25.39 | 28-APR-16:03 | 593.90 | 21-APR-13:25 | 0.00 | 01-APR-00:10 |
| May | 0.198407E+10 | 0.524885E+09 | 509.58 | 0.196300E+10 | 21063254.63 | 0.00 | 0.29 | 16-MAY-13:50 | 0.00 | 01-MAY-00:10 | 3244.20 | 16-MAY-13:30 | 3244.20 | 16-MAY-13:30 | 114.63 | 31-MAY-08:50 | 883.92 | 16-MAY-13:50 | 0.00 | 01-MAY-00:10 |
| June | 0.530634E+10 | 0.143584E+10 | 716.25 | 0.508993E+10 | 0.216407E+09 | 0.00 | 0.45 | 26-JUN-15:10 | 0.00 | 03-JUN-05:35 | 4469.91 | 26-JUN-15:10 | 4469.91 | 26-JUN-15:10 | 725.54 | 18-JUN-10:00 | 1412.60 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.586044E+10 | 0.157610E+10 | 742.58 | 0.553340E+10 | 0.327042E+09 | 0.00 | 0.41 | 16-JUL-15:10 | 0.00 | 06-JUL-05:35 | 4417.03 | 23-JUL-13:50 | 4417.03 | 23-JUL-13:50 | 898.57 | 30-JUL-16:10 | 1305.11 | 23-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.592038E+10 | 0.158251E+10 | 743.19 | 0.564690E+10 | 0.273479E+09 | 0.00 | 0.49 | 16-AUG-14:00 | 0.00 | 02-AUG-05:40 | 5013.76 | 16-AUG-14:00 | 5013.76 | 16-AUG-14:00 | 768.56 | 05-AUG-15:40 | 1521.80 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.484869E+10 | 0.128656E+10 | 667.87 | 0.480982E+10 | 38870569.79 | 0.00 | 0.48 | 28-SEP-14:00 | 0.00 | 06-SEP-06:45 | 5255.53 | 28-SEP-14:00 | 5255.53 | 28-SEP-14:00 | 272.99 | 01-SEP-14:30 | 1450.31 | 28-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.214052E+10 | 0.558969E+09 | 335.68 | 0.214033E+10 | 191378.89 | 0.00 | 0.45 | 11-OCT-14:00 | 0.00 | 01-OCT-02:20 | 5155.59 | 11-OCT-14:10 | 5155.59 | 11-OCT-14:10 | 22.47 | 01-OCT-00:10 | 1355.97 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.104444E+10 | 0.273949E+09 | 203.48 | 0.104444E+10 | -0.0 | 0.00 | 0.38 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 | 4369.50 | 07-NOV-14:00 | 4369.50 | 07-NOV-14:00 | 0.00 | 09-NOV-11:50 | 1114.15 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.409922E+09 | 0.108366E+09 | 99.67 | 0.409922E+09 | -0.0 | 0.00 | 0.25 | 02-DEC-14:30 | 0.00 | 01-DEC-00:10 | 2769.63 | 02-DEC-14:30 | 2769.63 | 02-DEC-14:30 | 0.00 | 02-DEC-14:30 | 721.32 | 02-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.301597E+11 | 0.804364E+10 | 4628.46 | 0.292826E+11 | 0.877118E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.350894E+09 | 93364591.07 | 99.67 | 0.350829E+09 | -0.0 | 0.00 | 0.20 | 0.00 | 2265.00 | 2265.00 | 0.00 | 593.90 | 0.00 | |||||||
| Maximum of Months | 0.592038E+10 | 0.158251E+10 | 743.19 | 0.564690E+10 | 0.327042E+09 | 0.00 | 0.49 | 0.00 | 5255.53 | 5255.53 | 898.57 | 1521.80 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.728327E+09 | 0.191908E+09 | 168.26 | 0.728327E+09 | -0.0 | 0.00 | 0.35 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 3930.50 | 20-JAN-14:00 | 3930.50 | 20-JAN-14:00 | 0.00 | 20-JAN-11:50 | 1007.84 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.520445E+09 | 0.137453E+09 | 125.33 | 0.520445E+09 | 0.00 | 0.00 | 0.31 | 18-FEB-13:30 | 0.00 | 01-FEB-00:10 | 3442.61 | 18-FEB-13:30 | 3442.61 | 18-FEB-13:30 | 0.00 | 18-FEB-12:20 | 888.46 | 18-FEB-13:30 | 0.00 | 01-FEB-00:10 |
| March | 0.106073E+10 | 0.277724E+09 | 191.53 | 0.106073E+10 | 0.00 | 0.00 | 0.39 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 4497.11 | 14-MAR-13:00 | 4497.11 | 14-MAR-13:00 | 0.00 | 10-MAR-15:10 | 1146.26 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.359624E+09 | 95665946.43 | 128.73 | 0.359554E+09 | 70014.70 | 0.00 | 0.21 | 21-APR-13:25 | 0.00 | 01-APR-00:10 | 2297.93 | 21-APR-13:25 | 2297.93 | 21-APR-13:25 | 26.59 | 28-APR-16:03 | 602.21 | 21-APR-13:25 | 0.00 | 01-APR-00:10 |
| May | 0.199677E+10 | 0.528181E+09 | 511.05 | 0.197570E+10 | 21070798.09 | 0.00 | 0.30 | 16-MAY-13:40 | 0.00 | 01-MAY-00:10 | 3263.14 | 16-MAY-13:30 | 3263.14 | 16-MAY-13:30 | 115.98 | 31-MAY-08:50 | 887.97 | 16-MAY-13:50 | 0.00 | 01-MAY-00:10 |
| June | 0.531544E+10 | 0.143806E+10 | 716.25 | 0.509862E+10 | 0.216826E+09 | 0.00 | 0.45 | 26-JUN-15:10 | 0.00 | 03-JUN-05:35 | 4467.42 | 26-JUN-15:10 | 4467.42 | 26-JUN-15:10 | 728.99 | 18-JUN-10:00 | 1411.57 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.587549E+10 | 0.157987E+10 | 742.75 | 0.554794E+10 | 0.327545E+09 | 0.00 | 0.42 | 16-JUL-15:10 | 0.00 | 06-JUL-05:35 | 4432.33 | 23-JUL-13:50 | 4432.33 | 23-JUL-13:50 | 896.44 | 30-JUL-16:10 | 1308.80 | 23-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.593490E+10 | 0.158604E+10 | 743.02 | 0.566069E+10 | 0.274204E+09 | 0.00 | 0.49 | 16-AUG-14:00 | 0.00 | 02-AUG-05:40 | 5019.09 | 16-AUG-14:00 | 5019.09 | 16-AUG-14:00 | 770.74 | 05-AUG-15:40 | 1522.94 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.485680E+10 | 0.128848E+10 | 667.87 | 0.481789E+10 | 38914575.32 | 0.00 | 0.48 | 28-SEP-13:50 | 0.00 | 04-SEP-06:40 | 5267.34 | 28-SEP-13:50 | 5267.34 | 28-SEP-13:50 | 273.38 | 01-SEP-14:30 | 1453.01 | 28-SEP-13:50 | 0.00 | 01-SEP-00:10 |
| October | 0.214118E+10 | 0.559077E+09 | 335.40 | 0.214099E+10 | 192356.25 | 0.00 | 0.46 | 11-OCT-14:00 | 0.00 | 01-OCT-02:20 | 5156.46 | 11-OCT-14:10 | 5156.46 | 11-OCT-14:10 | 22.54 | 01-OCT-00:10 | 1356.34 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.104636E+10 | 0.274415E+09 | 203.32 | 0.104636E+10 | -0.0 | 0.00 | 0.38 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 | 4373.74 | 07-NOV-14:00 | 4373.74 | 07-NOV-14:00 | 0.00 | 09-NOV-11:10 | 1114.96 | 07-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.411510E+09 | 0.108772E+09 | 100.17 | 0.411510E+09 | 0.00 | 0.00 | 0.25 | 02-DEC-14:30 | 0.00 | 01-DEC-00:10 | 2764.36 | 02-DEC-14:30 | 2764.36 | 02-DEC-14:30 | 0.00 | 02-DEC-13:30 | 719.91 | 02-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.302476E+11 | 0.806564E+10 | 4633.69 | 0.293687E+11 | 0.878823E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.359624E+09 | 95665946.43 | 100.17 | 0.359554E+09 | -0.0 | 0.00 | 0.21 | 0.00 | 2297.93 | 2297.93 | 0.00 | 602.21 | 0.00 | |||||||
| Maximum of Months | 0.593490E+10 | 0.158604E+10 | 743.02 | 0.566069E+10 | 0.327545E+09 | 0.00 | 0.49 | 0.00 | 5267.34 | 5267.34 | 896.44 | 1522.94 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.328123E+09 | 86346577.54 | 103.83 | 0.328123E+09 | 0.00 | 0.00 | 0.36 | 20-JAN-15:10 | 0.00 | 01-JAN-00:10 | 2875.26 | 20-JAN-15:10 | 2875.26 | 20-JAN-15:10 | 0.00 | 20-JAN-15:30 | 735.56 | 20-JAN-15:10 | 0.00 | 01-JAN-00:10 |
| February | 0.304030E+09 | 80147057.10 | 89.92 | 0.304030E+09 | -0.0 | 0.00 | 0.33 | 18-FEB-14:30 | 0.00 | 01-FEB-00:10 | 2596.89 | 18-FEB-14:30 | 2596.89 | 18-FEB-14:30 | 0.00 | 23-FEB-15:00 | 667.84 | 18-FEB-14:30 | 0.00 | 01-FEB-00:10 |
| March | 0.666092E+09 | 0.173767E+09 | 144.75 | 0.666092E+09 | 0.00 | 0.00 | 0.43 | 13-MAR-15:30 | 0.00 | 01-MAR-00:10 | 3489.67 | 13-MAR-15:30 | 3489.67 | 13-MAR-15:30 | 0.00 | 11-MAR-15:40 | 882.54 | 13-MAR-15:30 | 0.00 | 01-MAR-00:10 |
| April | 0.380593E+09 | 0.100418E+09 | 119.72 | 0.380577E+09 | 16252.89 | 0.00 | 0.31 | 07-APR-15:30 | 0.00 | 01-APR-00:10 | 2410.19 | 07-APR-15:30 | 2410.19 | 07-APR-15:30 | 15.39 | 28-APR-15:55 | 622.03 | 07-APR-15:30 | 0.00 | 01-APR-00:10 |
| May | 0.108845E+10 | 0.286851E+09 | 293.90 | 0.108478E+10 | 3669290.94 | 0.00 | 0.42 | 31-MAY-16:03 | 0.00 | 01-MAY-00:10 | 3365.36 | 31-MAY-16:07 | 3365.36 | 31-MAY-16:07 | 56.39 | 30-MAY-17:40 | 894.51 | 31-MAY-16:03 | 0.00 | 01-MAY-00:10 |
| June | 0.360129E+10 | 0.977017E+09 | 566.39 | 0.350330E+10 | 97986408.12 | 0.00 | 0.65 | 26-JUN-16:40 | 0.00 | 01-JUN-01:20 | 4725.97 | 26-JUN-17:03 | 4725.97 | 26-JUN-17:03 | 504.82 | 22-JUN-14:00 | 1415.43 | 26-JUN-16:40 | 0.00 | 01-JUN-00:10 |
| July | 0.372885E+10 | 0.100905E+10 | 622.07 | 0.357984E+10 | 0.149013E+09 | 0.00 | 0.58 | 15-JUL-15:20 | 0.00 | 01-JUL-05:05 | 4380.78 | 15-JUL-15:30 | 4380.78 | 15-JUL-15:30 | 766.74 | 30-JUL-16:10 | 1261.12 | 15-JUL-15:20 | 0.00 | 01-JUL-00:10 |
| August | 0.366475E+10 | 0.984328E+09 | 591.58 | 0.356010E+10 | 0.104649E+09 | 0.00 | 0.67 | 16-AUG-16:01 | 0.00 | 01-AUG-04:30 | 4949.37 | 16-AUG-16:04 | 4949.37 | 16-AUG-16:04 | 683.95 | 05-AUG-15:40 | 1454.29 | 16-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.265101E+10 | 0.704554E+09 | 453.61 | 0.263922E+10 | 11796104.44 | 0.00 | 0.56 | 10-SEP-15:20 | 0.00 | 01-SEP-02:50 | 4330.23 | 10-SEP-15:20 | 4330.23 | 10-SEP-15:20 | 227.90 | 01-SEP-14:20 | 1201.18 | 10-SEP-15:20 | 0.00 | 01-SEP-00:10 |
| October | 0.103842E+10 | 0.270374E+09 | 205.81 | 0.103842E+10 | 0.00 | 0.00 | 0.50 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 4019.03 | 11-OCT-15:10 | 4019.03 | 11-OCT-15:10 | 0.00 | 08-OCT-15:20 | 1034.10 | 11-OCT-14:40 | 0.00 | 01-OCT-00:10 |
| November | 0.518086E+09 | 0.135688E+09 | 131.92 | 0.518086E+09 | 0.00 | 0.00 | 0.40 | 05-NOV-15:10 | 0.00 | 01-NOV-00:10 | 3167.58 | 05-NOV-15:10 | 3167.58 | 05-NOV-15:10 | 0.00 | 04-NOV-14:40 | 805.91 | 05-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.251775E+09 | 66282396.09 | 72.67 | 0.251775E+09 | -0.0 | 0.00 | 0.31 | 01-DEC-14:50 | 0.00 | 01-DEC-00:10 | 2492.36 | 01-DEC-14:50 | 2492.36 | 01-DEC-14:50 | 0.00 | 02-DEC-14:20 | 642.23 | 01-DEC-14:50 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.182215E+11 | 0.487482E+10 | 3396.16 | 0.178543E+11 | 0.367130E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.251775E+09 | 66282396.09 | 72.67 | 0.251775E+09 | -0.0 | 0.00 | 0.31 | 0.00 | 2410.19 | 2410.19 | 0.00 | 622.03 | 0.00 | |||||||
| Maximum of Months | 0.372885E+10 | 0.100905E+10 | 622.07 | 0.357984E+10 | 0.149013E+09 | 0.00 | 0.67 | 0.00 | 4949.37 | 4949.37 | 766.74 | 1454.29 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 1067560.36 | 287914.73 | 2.50 | 1067560.36 | 0.00 | 0.00 | 0.03 | 20-JAN-16:30 | 0.00 | 01-JAN-00:10 | 209.03 | 20-JAN-16:30 | 209.03 | 20-JAN-16:30 | 0.00 | 20-JAN-15:00 | 56.30 | 20-JAN-16:30 | 0.00 | 01-JAN-00:10 |
| February | 795429.87 | 214702.80 | 2.58 | 795429.87 | -0.0 | 0.00 | 0.02 | 18-FEB-17:35 | 0.00 | 01-FEB-00:10 | 132.85 | 18-FEB-17:35 | 132.85 | 18-FEB-17:35 | 0.00 | 18-FEB-17:30 | 35.83 | 18-FEB-17:35 | 0.00 | 01-FEB-00:10 |
| March | 0.114577E+09 | 30439384.51 | 54.15 | 0.114577E+09 | -0.0 | 0.00 | 0.22 | 13-MAR-16:30 | 0.00 | 01-MAR-00:10 | 1721.42 | 13-MAR-16:30 | 1721.42 | 13-MAR-16:30 | 0.00 | 14-MAR-16:35 | 450.03 | 13-MAR-16:30 | 0.00 | 01-MAR-00:10 |
| April | 0.101842E+09 | 27145984.41 | 60.21 | 0.101842E+09 | 0.00 | 0.00 | 0.17 | 20-APR-17:20 | 0.00 | 01-APR-00:10 | 1341.30 | 20-APR-17:20 | 1341.30 | 20-APR-17:20 | 0.00 | 07-APR-16:40 | 353.26 | 20-APR-17:20 | 0.00 | 01-APR-00:10 |
| May | 0.815275E+09 | 0.215912E+09 | 260.92 | 0.812143E+09 | 3131893.08 | 0.00 | 0.39 | 31-MAY-16:25 | 0.00 | 01-MAY-00:10 | 3112.59 | 31-MAY-17:05 | 3112.59 | 31-MAY-17:05 | 60.56 | 30-MAY-17:20 | 825.13 | 31-MAY-16:30 | 0.00 | 01-MAY-00:10 |
| June | 0.339727E+10 | 0.923714E+09 | 575.42 | 0.330140E+10 | 95868205.64 | 0.00 | 0.64 | 26-JUN-17:20 | 0.00 | 01-JUN-01:20 | 4672.91 | 26-JUN-17:15 | 4672.91 | 26-JUN-17:15 | 453.84 | 22-JUN-14:00 | 1396.35 | 26-JUN-17:15 | 0.00 | 01-JUN-00:10 |
| July | 0.343995E+10 | 0.933729E+09 | 624.72 | 0.329859E+10 | 0.141360E+09 | 0.00 | 0.55 | 15-JUL-17:30 | 0.00 | 01-JUL-05:05 | 4082.45 | 15-JUL-17:30 | 4082.45 | 15-JUL-17:30 | 676.76 | 30-JUL-16:00 | 1164.68 | 15-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.293674E+10 | 0.795662E+09 | 579.93 | 0.284361E+10 | 93133327.09 | 0.00 | 0.60 | 16-AUG-16:30 | 0.00 | 01-AUG-04:20 | 4391.67 | 16-AUG-16:30 | 4391.67 | 16-AUG-16:30 | 617.20 | 05-AUG-15:40 | 1297.94 | 16-AUG-16:30 | 0.00 | 01-AUG-00:10 |
| September | 0.165677E+10 | 0.447757E+09 | 402.86 | 0.164853E+10 | 8235823.55 | 0.00 | 0.45 | 10-SEP-16:20 | 0.00 | 01-SEP-02:20 | 3369.06 | 10-SEP-16:30 | 3369.06 | 10-SEP-16:30 | 155.05 | 01-SEP-14:30 | 948.63 | 10-SEP-16:20 | 0.00 | 01-SEP-00:10 |
| October | 0.162404E+09 | 43313868.51 | 78.98 | 0.162404E+09 | 0.00 | 0.00 | 0.26 | 11-OCT-15:30 | 0.00 | 01-OCT-00:10 | 2012.14 | 11-OCT-15:30 | 2012.14 | 11-OCT-15:30 | 0.00 | 09-OCT-16:08 | 531.04 | 11-OCT-15:30 | 0.00 | 01-OCT-00:10 |
| November | 17201250.45 | 4615040.16 | 16.48 | 17201250.45 | 0.00 | 0.00 | 0.09 | 07-NOV-15:30 | 0.00 | 01-NOV-00:10 | 689.80 | 07-NOV-15:30 | 689.80 | 07-NOV-15:30 | 0.00 | 05-NOV-15:20 | 184.01 | 07-NOV-15:30 | 0.00 | 01-NOV-00:10 |
| December | 657353.21 | 177361.55 | 1.83 | 657353.21 | 0.00 | 0.00 | 0.02 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 | 158.60 | 02-DEC-15:00 | 158.60 | 02-DEC-15:00 | 0.00 | 02-DEC-15:00 | 42.76 | 02-DEC-15:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.126445E+11 | 0.342297E+10 | 2660.58 | 0.123028E+11 | 0.341729E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 657353.21 | 177361.55 | 1.83 | 657353.21 | -0.0 | 0.00 | 0.02 | 0.00 | 132.85 | 132.85 | 0.00 | 35.83 | 0.00 | |||||||
| Maximum of Months | 0.343995E+10 | 0.933729E+09 | 624.72 | 0.330140E+10 | 0.141360E+09 | 0.00 | 0.64 | 0.00 | 4672.91 | 4672.91 | 676.76 | 1396.35 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.293110E+09 | 77027232.69 | 101.92 | 0.293110E+09 | 0.00 | 0.00 | 0.40 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 2673.71 | 20-JAN-14:00 | 2673.71 | 20-JAN-14:00 | 0.00 | 19-JAN-13:20 | 679.91 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.286666E+09 | 75360926.46 | 95.59 | 0.286666E+09 | 0.00 | 0.00 | 0.37 | 18-FEB-13:40 | 0.00 | 01-FEB-00:10 | 2444.47 | 18-FEB-13:40 | 2444.47 | 18-FEB-13:40 | 0.00 | 18-FEB-12:50 | 624.82 | 18-FEB-13:40 | 0.00 | 01-FEB-00:10 |
| March | 0.646339E+09 | 0.168010E+09 | 147.00 | 0.646339E+09 | 0.00 | 0.00 | 0.46 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 | 3127.39 | 14-MAR-13:00 | 3127.39 | 14-MAR-13:00 | 0.00 | 11-MAR-12:30 | 788.46 | 14-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.381122E+09 | 0.100161E+09 | 129.48 | 0.381118E+09 | 3530.40 | 0.00 | 0.33 | 19-APR-13:30 | 0.00 | 01-APR-00:10 | 2207.20 | 19-APR-13:30 | 2207.20 | 19-APR-13:30 | 5.17 | 28-APR-16:06 | 567.19 | 19-APR-13:30 | 0.00 | 01-APR-00:10 |
| May | 0.110536E+10 | 0.290200E+09 | 316.67 | 0.110191E+10 | 3444331.09 | 0.00 | 0.43 | 16-MAY-13:40 | 0.00 | 01-MAY-00:10 | 2847.51 | 16-MAY-13:30 | 2847.51 | 16-MAY-13:30 | 83.04 | 31-MAY-09:00 | 758.13 | 16-MAY-13:50 | 0.00 | 01-MAY-00:10 |
| June | 0.368857E+10 | 0.990635E+09 | 584.23 | 0.358165E+10 | 0.106918E+09 | 0.00 | 0.66 | 26-JUN-15:00 | 0.00 | 01-JUN-00:30 | 3981.60 | 30-JUN-14:00 | 3981.60 | 30-JUN-14:00 | 581.57 | 18-JUN-09:40 | 1214.80 | 26-JUN-15:00 | 0.00 | 01-JUN-00:10 |
| July | 0.391810E+10 | 0.104900E+10 | 635.60 | 0.376269E+10 | 0.155400E+09 | 0.00 | 0.62 | 15-JUL-14:00 | 0.00 | 01-JUL-05:05 | 3974.52 | 23-JUL-13:30 | 3974.52 | 23-JUL-13:30 | 672.99 | 30-JUL-16:10 | 1134.55 | 23-JUL-13:50 | 0.00 | 01-JUL-00:10 |
| August | 0.383504E+10 | 0.101795E+10 | 611.01 | 0.371699E+10 | 0.118047E+09 | 0.00 | 0.72 | 16-AUG-14:00 | 0.00 | 01-AUG-04:20 | 4460.38 | 16-AUG-13:20 | 4460.38 | 16-AUG-13:20 | 597.21 | 05-AUG-15:40 | 1298.12 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.271087E+10 | 0.714253E+09 | 465.17 | 0.269756E+10 | 13317227.10 | 0.00 | 0.63 | 09-SEP-12:50 | 0.00 | 01-SEP-02:40 | 4101.95 | 09-SEP-12:50 | 4101.95 | 09-SEP-12:50 | 213.73 | 01-SEP-14:20 | 1137.70 | 09-SEP-12:50 | 0.00 | 01-SEP-00:10 |
| October | 0.984505E+09 | 0.255615E+09 | 215.10 | 0.984505E+09 | 0.00 | 0.00 | 0.53 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 | 3526.09 | 11-OCT-14:00 | 3526.09 | 11-OCT-14:00 | 0.00 | 01-OCT-11:10 | 917.56 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.484778E+09 | 0.126644E+09 | 134.58 | 0.484778E+09 | 0.00 | 0.00 | 0.42 | 05-NOV-13:30 | 0.00 | 01-NOV-00:10 | 2806.86 | 05-NOV-13:30 | 2806.86 | 05-NOV-13:30 | 0.00 | 05-NOV-12:40 | 711.65 | 05-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.224571E+09 | 59099193.11 | 74.67 | 0.224571E+09 | 0.00 | 0.00 | 0.32 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2099.19 | 01-DEC-14:00 | 2099.19 | 01-DEC-14:00 | 0.00 | 01-DEC-12:20 | 540.76 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.185590E+11 | 0.492395E+10 | 3511.01 | 0.181619E+11 | 0.397131E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.224571E+09 | 59099193.11 | 74.67 | 0.224571E+09 | 0.00 | 0.00 | 0.32 | 0.00 | 2099.19 | 2099.19 | 0.00 | 540.76 | 0.00 | |||||||
| Maximum of Months | 0.391810E+10 | 0.104900E+10 | 635.60 | 0.376269E+10 | 0.155400E+09 | 0.00 | 0.72 | 0.00 | 4460.38 | 4460.38 | 672.99 | 1298.12 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 92659.89 | 25044.06 | 1.00 | 92659.89 | 0.00 | 0.00 | 0.01 | 18-FEB-14:30 | 0.00 | 01-FEB-00:10 | 34.32 | 18-FEB-14:30 | 34.32 | 18-FEB-14:30 | 0.00 | 18-FEB-14:30 | 9.28 | 18-FEB-14:30 | 0.00 | 01-FEB-00:10 |
| March | 77831833.78 | 20713675.89 | 48.54 | 77831833.78 | -0.0 | 0.00 | 0.17 | 14-MAR-13:40 | 0.00 | 01-MAR-00:10 | 1073.46 | 14-MAR-13:40 | 1073.46 | 14-MAR-13:40 | 0.00 | 13-MAR-12:50 | 283.03 | 14-MAR-13:40 | 0.00 | 01-MAR-00:10 |
| April | 0.102730E+09 | 27335578.39 | 58.92 | 0.102730E+09 | 222.25 | 0.00 | 0.19 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 1223.73 | 20-APR-13:00 | 1223.73 | 20-APR-13:00 | 0.37 | 28-APR-13:10 | 321.52 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
| May | 0.821897E+09 | 0.217165E+09 | 281.97 | 0.819060E+09 | 2836991.72 | 0.00 | 0.36 | 17-MAY-13:40 | 0.00 | 01-MAY-00:10 | 2266.80 | 17-MAY-13:40 | 2266.80 | 17-MAY-13:40 | 88.92 | 31-MAY-08:50 | 623.78 | 17-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.349395E+10 | 0.940820E+09 | 591.05 | 0.338851E+10 | 0.105442E+09 | 0.00 | 0.60 | 26-JUN-15:10 | 0.00 | 01-JUN-00:20 | 3616.09 | 26-JUN-17:03 | 3616.09 | 26-JUN-17:03 | 515.22 | 18-JUN-09:30 | 1107.71 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.363393E+10 | 0.976547E+09 | 637.62 | 0.348557E+10 | 0.148355E+09 | 0.00 | 0.58 | 16-JUL-14:40 | 0.00 | 01-JUL-04:40 | 3584.54 | 16-JUL-14:40 | 3584.54 | 16-JUL-14:40 | 569.53 | 30-JUL-16:10 | 1049.45 | 16-JUL-14:40 | 0.00 | 01-JUL-00:10 |
| August | 0.310540E+10 | 0.832804E+09 | 597.74 | 0.299761E+10 | 0.107792E+09 | 0.00 | 0.56 | 16-AUG-14:00 | 0.00 | 01-AUG-02:50 | 3372.96 | 16-AUG-14:00 | 3372.96 | 16-AUG-14:00 | 562.02 | 04-AUG-07:35 | 1011.62 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.168759E+10 | 0.453830E+09 | 418.28 | 0.167778E+10 | 9810136.16 | 0.00 | 0.44 | 09-SEP-13:20 | 0.00 | 01-SEP-02:20 | 2763.39 | 09-SEP-13:30 | 2763.39 | 09-SEP-13:30 | 156.02 | 01-SEP-09:40 | 784.67 | 09-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.106305E+09 | 28408806.60 | 60.26 | 0.106305E+09 | -0.0 | 0.00 | 0.22 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 | 1383.75 | 11-OCT-14:10 | 1383.75 | 11-OCT-14:10 | 0.00 | 07-OCT-13:40 | 377.19 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 8229329.41 | 2215173.94 | 13.50 | 8229329.41 | -0.0 | 0.00 | 0.05 | 06-NOV-14:00 | 0.00 | 01-NOV-00:10 | 302.97 | 06-NOV-14:00 | 302.97 | 06-NOV-14:00 | 0.00 | 06-NOV-13:30 | 81.35 | 06-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.130380E+11 | 0.349986E+10 | 2708.87 | 0.126637E+11 | 0.374237E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.363393E+10 | 0.976547E+09 | 637.62 | 0.348557E+10 | 0.148355E+09 | 0.00 | 0.60 | 0.00 | 3616.09 | 3616.09 | 569.53 | 1107.71 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 35567215.83 | 9510583.66 | 30.31 | 35567215.83 | 0.00 | 0.00 | 0.11 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 | 685.21 | 14-MAR-16:07 | 685.21 | 14-MAR-16:07 | 0.00 | 14-MAR-17:15 | 182.13 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 40583745.06 | 10860191.35 | 38.50 | 40583745.06 | 0.00 | 0.00 | 0.12 | 20-APR-13:20 | 0.00 | 01-APR-00:10 | 690.96 | 20-APR-13:20 | 690.96 | 20-APR-13:20 | 0.00 | 20-APR-12:50 | 183.63 | 20-APR-13:20 | 0.00 | 01-APR-00:10 |
| May | 0.576150E+09 | 0.153103E+09 | 268.10 | 0.573497E+09 | 2652616.17 | 0.00 | 0.30 | 31-MAY-16:07 | 0.00 | 01-MAY-00:10 | 1835.10 | 31-MAY-16:07 | 1835.10 | 31-MAY-16:07 | 46.43 | 30-MAY-17:20 | 496.74 | 31-MAY-16:07 | 0.00 | 01-MAY-00:10 |
| June | 0.269925E+10 | 0.733682E+09 | 623.16 | 0.260911E+10 | 90138247.06 | 0.00 | 0.54 | 26-JUN-17:30 | 0.00 | 01-JUN-02:00 | 3024.65 | 26-JUN-17:23 | 3024.65 | 26-JUN-17:23 | 380.63 | 18-JUN-10:00 | 919.26 | 26-JUN-17:23 | 0.00 | 01-JUN-00:10 |
| July | 0.286529E+10 | 0.775560E+09 | 664.66 | 0.272940E+10 | 0.135891E+09 | 0.00 | 0.49 | 16-JUL-15:10 | 0.00 | 01-JUL-05:05 | 2768.03 | 16-JUL-15:10 | 2768.03 | 16-JUL-15:10 | 485.60 | 30-JUL-16:10 | 825.11 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.237944E+10 | 0.643669E+09 | 618.71 | 0.228764E+10 | 91800231.95 | 0.00 | 0.49 | 16-AUG-16:06 | 0.00 | 01-AUG-05:05 | 2773.21 | 16-AUG-16:17 | 2773.21 | 16-AUG-16:17 | 427.69 | 05-AUG-15:40 | 836.74 | 16-AUG-16:06 | 0.00 | 01-AUG-00:10 |
| September | 0.128968E+10 | 0.349062E+09 | 433.61 | 0.128162E+10 | 8054372.01 | 0.00 | 0.36 | 09-SEP-13:30 | 0.00 | 01-SEP-02:50 | 2105.16 | 09-SEP-14:10 | 2105.16 | 09-SEP-14:10 | 102.60 | 01-SEP-14:30 | 602.86 | 09-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 60574538.35 | 16274997.44 | 43.61 | 60574538.35 | -0.0 | 0.00 | 0.18 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1082.08 | 11-OCT-15:10 | 1082.08 | 11-OCT-15:10 | 0.00 | 07-OCT-16:07 | 291.80 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 1020203.24 | 275491.85 | 5.33 | 1020203.24 | -0.0 | 0.00 | 0.02 | 07-NOV-15:10 | 0.00 | 01-NOV-00:10 | 94.73 | 07-NOV-15:10 | 94.73 | 07-NOV-15:10 | 0.00 | 07-NOV-15:20 | 25.56 | 07-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.994756E+10 | 0.269200E+10 | 2725.99 | 0.961902E+10 | 0.328537E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.286529E+10 | 0.775560E+09 | 664.66 | 0.272940E+10 | 0.135891E+09 | 0.00 | 0.54 | 0.00 | 3024.65 | 3024.65 | 485.60 | 919.26 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 36794472.75 | 9835269.77 | 31.21 | 36794472.75 | -0.0 | 0.00 | 0.12 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 | 696.66 | 14-MAR-16:07 | 696.66 | 14-MAR-16:07 | 0.00 | 14-MAR-14:40 | 185.09 | 14-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 43145800.88 | 11542224.65 | 40.33 | 43145800.88 | 0.00 | 0.00 | 0.12 | 20-APR-13:20 | 0.00 | 01-APR-00:10 | 726.03 | 20-APR-13:20 | 726.03 | 20-APR-13:20 | 0.00 | 20-APR-16:10 | 192.76 | 20-APR-13:20 | 0.00 | 01-APR-00:10 |
| May | 0.584377E+09 | 0.155255E+09 | 272.00 | 0.581702E+09 | 2674389.79 | 0.00 | 0.30 | 31-MAY-16:07 | 0.00 | 01-MAY-00:10 | 1818.26 | 31-MAY-16:07 | 1818.26 | 31-MAY-16:07 | 46.47 | 31-MAY-09:20 | 492.23 | 31-MAY-16:07 | 0.00 | 01-MAY-00:10 |
| June | 0.270629E+10 | 0.735309E+09 | 622.97 | 0.261581E+10 | 90475494.07 | 0.00 | 0.54 | 26-JUN-17:20 | 0.00 | 01-JUN-01:50 | 2998.55 | 26-JUN-17:15 | 2998.55 | 26-JUN-17:15 | 384.86 | 18-JUN-10:00 | 911.45 | 26-JUN-17:15 | 0.00 | 01-JUN-00:10 |
| July | 0.287563E+10 | 0.778064E+09 | 664.87 | 0.273944E+10 | 0.136193E+09 | 0.00 | 0.49 | 16-JUL-15:10 | 0.00 | 01-JUL-05:05 | 2770.91 | 16-JUL-15:10 | 2770.91 | 16-JUL-15:10 | 482.41 | 30-JUL-16:10 | 825.48 | 16-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.238982E+10 | 0.646211E+09 | 619.18 | 0.229751E+10 | 92315735.15 | 0.00 | 0.49 | 16-AUG-16:07 | 0.00 | 01-AUG-05:05 | 2752.71 | 16-AUG-16:17 | 2752.71 | 16-AUG-16:17 | 428.08 | 05-AUG-15:40 | 830.98 | 16-AUG-16:07 | 0.00 | 01-AUG-00:10 |
| September | 0.129707E+10 | 0.350965E+09 | 434.30 | 0.128896E+10 | 8113155.57 | 0.00 | 0.37 | 09-SEP-13:30 | 0.00 | 01-SEP-02:50 | 2113.88 | 09-SEP-13:30 | 2113.88 | 09-SEP-13:30 | 103.22 | 01-SEP-14:30 | 606.04 | 09-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 61512407.36 | 16523564.22 | 42.90 | 61512407.36 | 0.00 | 0.00 | 0.18 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1077.53 | 11-OCT-15:10 | 1077.53 | 11-OCT-15:10 | 0.00 | 10-OCT-14:10 | 290.55 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 1275830.97 | 344455.81 | 6.00 | 1275830.97 | -0.0 | 0.00 | 0.02 | 07-NOV-15:10 | 0.00 | 01-NOV-00:10 | 103.53 | 07-NOV-15:10 | 103.53 | 07-NOV-15:10 | 0.00 | 07-NOV-15:40 | 27.93 | 07-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.999592E+10 | 0.270405E+10 | 2733.76 | 0.966615E+10 | 0.329772E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.287563E+10 | 0.778064E+09 | 664.87 | 0.273944E+10 | 0.136193E+09 | 0.00 | 0.54 | 0.00 | 2998.55 | 2998.55 | 482.41 | 911.45 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.333782E+09 | 87697808.04 | 118.69 | 0.333782E+09 | 0.00 | 0.00 | 0.40 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 2555.50 | 20-JAN-14:00 | 2555.50 | 20-JAN-14:00 | 0.00 | 24-JAN-15:00 | 649.31 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.287800E+09 | 75733007.05 | 102.05 | 0.287800E+09 | -0.0 | 0.00 | 0.36 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 | 2241.42 | 18-FEB-14:00 | 2241.42 | 18-FEB-14:00 | 0.00 | 18-FEB-12:30 | 573.78 | 18-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.548414E+09 | 0.143069E+09 | 152.75 | 0.548414E+09 | -0.0 | 0.00 | 0.43 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 | 2712.51 | 15-MAR-13:50 | 2712.51 | 15-MAR-13:50 | 0.00 | 13-MAR-16:07 | 686.65 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 |
| April | 0.275394E+09 | 72769134.06 | 122.90 | 0.275379E+09 | 15518.57 | 0.00 | 0.27 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 1681.65 | 20-APR-13:00 | 1681.65 | 20-APR-13:00 | 11.28 | 28-APR-16:00 | 436.31 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
| May | 0.849694E+09 | 0.224339E+09 | 315.58 | 0.846271E+09 | 3422881.43 | 0.00 | 0.37 | 16-MAY-14:00 | 0.00 | 01-MAY-00:10 | 2258.49 | 16-MAY-13:50 | 2258.49 | 16-MAY-13:50 | 49.04 | 22-MAY-13:10 | 610.01 | 16-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.289988E+10 | 0.786124E+09 | 611.15 | 0.280742E+10 | 92462336.43 | 0.00 | 0.58 | 26-JUN-15:10 | 0.00 | 01-JUN-02:00 | 3258.32 | 26-JUN-15:10 | 3258.32 | 26-JUN-15:10 | 464.21 | 18-JUN-10:00 | 1007.86 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.315533E+10 | 0.851009E+09 | 659.24 | 0.301107E+10 | 0.144260E+09 | 0.00 | 0.54 | 15-JUL-14:00 | 0.00 | 01-JUL-05:05 | 3242.98 | 23-JUL-13:40 | 3242.98 | 23-JUL-13:40 | 591.60 | 30-JUL-16:10 | 937.54 | 23-JUL-13:50 | 0.00 | 01-JUL-00:10 |
| August | 0.311801E+10 | 0.834689E+09 | 636.42 | 0.301356E+10 | 0.104444E+09 | 0.00 | 0.64 | 16-AUG-14:00 | 0.00 | 01-AUG-05:05 | 3691.38 | 16-AUG-14:00 | 3691.38 | 16-AUG-14:00 | 502.39 | 05-AUG-15:40 | 1093.32 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.230946E+10 | 0.612110E+09 | 491.78 | 0.229718E+10 | 12278792.23 | 0.00 | 0.57 | 28-SEP-13:40 | 0.00 | 01-SEP-03:30 | 3516.99 | 28-SEP-13:40 | 3516.99 | 28-SEP-13:40 | 184.40 | 01-SEP-14:20 | 960.25 | 09-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.907903E+09 | 0.236197E+09 | 226.00 | 0.907903E+09 | 0.00 | 0.00 | 0.51 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 | 3239.84 | 11-OCT-14:10 | 3239.84 | 11-OCT-14:10 | 0.00 | 08-OCT-13:10 | 844.20 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.497693E+09 | 0.130095E+09 | 151.15 | 0.497693E+09 | 0.00 | 0.00 | 0.41 | 05-NOV-13:50 | 0.00 | 01-NOV-00:10 | 2626.55 | 05-NOV-13:50 | 2626.55 | 05-NOV-13:50 | 0.00 | 05-NOV-12:20 | 666.24 | 05-NOV-13:50 | 0.00 | 01-NOV-00:10 |
| December | 0.258349E+09 | 67893646.07 | 84.65 | 0.258349E+09 | -0.0 | 0.00 | 0.32 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2023.53 | 01-DEC-14:00 | 2023.53 | 01-DEC-14:00 | 0.00 | 01-DEC-13:30 | 520.71 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.154417E+11 | 0.412172E+10 | 3672.36 | 0.150848E+11 | 0.356883E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.258349E+09 | 67893646.07 | 84.65 | 0.258349E+09 | -0.0 | 0.00 | 0.27 | 0.00 | 1681.65 | 1681.65 | 0.00 | 436.31 | 0.00 | |||||||
| Maximum of Months | 0.315533E+10 | 0.851009E+09 | 659.24 | 0.301356E+10 | 0.144260E+09 | 0.00 | 0.64 | 0.00 | 3691.38 | 3691.38 | 591.60 | 1093.32 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.337744E+09 | 88711931.28 | 118.96 | 0.337744E+09 | 0.00 | 0.00 | 0.41 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 2565.80 | 20-JAN-14:00 | 2565.80 | 20-JAN-14:00 | 0.00 | 19-JAN-16:30 | 651.49 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.293345E+09 | 77159519.86 | 103.27 | 0.293345E+09 | -0.0 | 0.00 | 0.36 | 18-FEB-13:40 | 0.00 | 01-FEB-00:10 | 2257.02 | 18-FEB-13:40 | 2257.02 | 18-FEB-13:40 | 0.00 | 18-FEB-15:00 | 577.34 | 18-FEB-13:40 | 0.00 | 01-FEB-00:10 |
| March | 0.553458E+09 | 0.144321E+09 | 153.50 | 0.553458E+09 | 0.00 | 0.00 | 0.43 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 | 2728.45 | 15-MAR-13:50 | 2728.45 | 15-MAR-13:50 | 0.00 | 11-MAR-14:30 | 690.12 | 15-MAR-13:50 | 0.00 | 01-MAR-00:10 |
| April | 0.281505E+09 | 74349098.87 | 124.17 | 0.281489E+09 | 15796.61 | 0.00 | 0.28 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 1712.51 | 20-APR-13:00 | 1712.51 | 20-APR-13:00 | 11.57 | 28-APR-16:00 | 443.86 | 20-APR-13:00 | 0.00 | 01-APR-00:10 |
| May | 0.858774E+09 | 0.226663E+09 | 317.49 | 0.855336E+09 | 3438181.68 | 0.00 | 0.37 | 16-MAY-13:50 | 0.00 | 01-MAY-00:10 | 2274.60 | 16-MAY-13:50 | 2274.60 | 16-MAY-13:50 | 50.15 | 22-MAY-13:10 | 613.43 | 16-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.290746E+10 | 0.787827E+09 | 611.86 | 0.281467E+10 | 92786962.71 | 0.00 | 0.58 | 26-JUN-15:10 | 0.00 | 01-JUN-02:00 | 3252.15 | 26-JUN-15:10 | 3252.15 | 26-JUN-15:10 | 468.13 | 18-JUN-10:00 | 1005.52 | 26-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.316581E+10 | 0.853468E+09 | 659.69 | 0.302129E+10 | 0.144520E+09 | 0.00 | 0.54 | 15-JUL-14:00 | 0.00 | 01-JUL-05:05 | 3253.82 | 23-JUL-13:40 | 3253.82 | 23-JUL-13:40 | 588.67 | 30-JUL-16:10 | 939.52 | 23-JUL-13:50 | 0.00 | 01-JUL-00:10 |
| August | 0.312806E+10 | 0.836944E+09 | 636.64 | 0.302318E+10 | 0.104881E+09 | 0.00 | 0.65 | 16-AUG-14:00 | 0.00 | 01-AUG-05:05 | 3697.35 | 16-AUG-14:00 | 3697.35 | 16-AUG-14:00 | 502.45 | 05-AUG-15:40 | 1094.19 | 16-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.231690E+10 | 0.613787E+09 | 492.08 | 0.230457E+10 | 12328189.60 | 0.00 | 0.57 | 28-SEP-13:40 | 0.00 | 01-SEP-03:20 | 3530.51 | 28-SEP-13:40 | 3530.51 | 28-SEP-13:40 | 184.63 | 01-SEP-14:20 | 963.54 | 09-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.912368E+09 | 0.237268E+09 | 226.58 | 0.912368E+09 | -0.0 | 0.00 | 0.52 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 | 3240.77 | 11-OCT-14:10 | 3240.77 | 11-OCT-14:10 | 0.00 | 08-OCT-14:00 | 844.49 | 11-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.501643E+09 | 0.131082E+09 | 151.82 | 0.501643E+09 | 0.00 | 0.00 | 0.42 | 05-NOV-13:50 | 0.00 | 01-NOV-00:10 | 2633.52 | 05-NOV-13:50 | 2633.52 | 05-NOV-13:50 | 0.00 | 05-NOV-14:40 | 667.61 | 05-NOV-13:50 | 0.00 | 01-NOV-00:10 |
| December | 0.260560E+09 | 68454399.84 | 85.07 | 0.260560E+09 | -0.0 | 0.00 | 0.33 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2029.02 | 01-DEC-14:00 | 2029.02 | 01-DEC-14:00 | 0.00 | 01-DEC-13:10 | 521.88 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.155176E+11 | 0.414003E+10 | 3681.12 | 0.151596E+11 | 0.357971E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.260560E+09 | 68454399.84 | 85.07 | 0.260560E+09 | -0.0 | 0.00 | 0.28 | 0.00 | 1712.51 | 1712.51 | 0.00 | 443.86 | 0.00 | |||||||
| Maximum of Months | 0.316581E+10 | 0.853468E+09 | 659.69 | 0.302318E+10 | 0.144520E+09 | 0.00 | 0.65 | 0.00 | 3697.35 | 3697.35 | 588.67 | 1094.19 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 495.36 | 196.36 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 467.18 | 204.12 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 349.92 | 161.02 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 222.62 | 142.19 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 214.08 | 85.55 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 242.82 | 48.67 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 252.26 | 43.90 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 319.87 | 51.84 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 390.49 | 81.68 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 408.24 | 167.75 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 486.04 | 189.78 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 445.32 | 225.33 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 357.20 | 132.79 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 214.08 | 43.90 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 495.36 | 225.33 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 98.13 | 62.15 | 35.98 | 93.12 | 141.73 | 0.00 | 0.00 | 0.00 |
| February | 119.15 | 74.05 | 45.10 | 113.21 | 142.46 | 0.00 | 0.00 | 0.00 |
| March | 138.88 | 76.68 | 62.20 | 141.73 | 106.93 | 0.00 | 0.00 | 0.00 |
| April | 130.17 | 54.90 | 75.26 | 129.26 | 91.49 | 0.00 | 0.00 | 0.00 |
| May | 159.58 | 56.23 | 103.35 | 186.71 | 54.50 | 0.00 | 0.00 | 0.00 |
| June | 195.42 | 94.12 | 101.30 | 267.69 | 31.69 | 0.00 | 0.00 | 0.00 |
| July | 158.95 | 58.14 | 100.81 | 219.03 | 28.58 | 0.00 | 0.00 | 0.00 |
| August | 166.34 | 82.30 | 84.04 | 223.73 | 33.60 | 0.00 | 0.00 | 0.00 |
| September | 147.68 | 70.98 | 76.70 | 188.56 | 54.05 | 0.00 | 0.00 | 0.00 |
| October | 123.49 | 70.46 | 53.03 | 131.89 | 113.08 | 0.00 | 0.00 | 0.00 |
| November | 101.48 | 61.56 | 39.93 | 97.70 | 131.88 | 0.00 | 0.00 | 0.00 |
| December | 82.06 | 48.46 | 33.60 | 70.47 | 160.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 135.15 | 67.42 | 67.73 | 155.43 | 90.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82.06 | 48.46 | 33.60 | 70.47 | 28.58 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 195.42 | 94.12 | 103.35 | 267.69 | 160.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 98.13 | 62.15 | 35.98 | 96.95 | 134.81 | 0.00 | 0.00 | 0.00 |
| February | 119.15 | 74.05 | 45.10 | 117.17 | 137.29 | 0.00 | 0.00 | 0.00 |
| March | 138.88 | 76.68 | 62.20 | 145.81 | 102.31 | 0.00 | 0.00 | 0.00 |
| April | 130.17 | 54.90 | 75.26 | 131.75 | 89.18 | 0.00 | 0.00 | 0.00 |
| May | 159.58 | 56.23 | 103.35 | 188.58 | 53.05 | 0.00 | 0.00 | 0.00 |
| June | 195.42 | 94.12 | 101.30 | 268.13 | 31.54 | 0.00 | 0.00 | 0.00 |
| July | 158.95 | 58.14 | 100.81 | 219.52 | 28.38 | 0.00 | 0.00 | 0.00 |
| August | 166.34 | 82.30 | 84.04 | 225.06 | 32.92 | 0.00 | 0.00 | 0.00 |
| September | 147.68 | 70.98 | 76.70 | 190.83 | 52.19 | 0.00 | 0.00 | 0.00 |
| October | 123.49 | 70.46 | 53.03 | 136.11 | 106.53 | 0.00 | 0.00 | 0.00 |
| November | 101.48 | 61.56 | 39.93 | 102.57 | 123.31 | 0.00 | 0.00 | 0.00 |
| December | 82.06 | 48.46 | 33.60 | 73.65 | 154.50 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 135.15 | 67.42 | 67.73 | 158.18 | 86.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82.06 | 48.46 | 33.60 | 73.65 | 28.38 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 195.42 | 94.12 | 103.35 | 268.13 | 154.50 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 10.18 | 217.18 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 13.29 | 218.97 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 40.85 | 161.30 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 61.06 | 136.90 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 129.64 | 76.57 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 194.28 | 44.13 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 187.34 | 40.78 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 141.18 | 49.08 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.32 | 79.78 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 37.44 | 165.95 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 15.57 | 195.58 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.98 | 249.73 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 78.88 | 135.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.98 | 40.78 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 194.28 | 249.73 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 499.25 | 187.18 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 470.87 | 189.39 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 351.69 | 152.67 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 223.24 | 136.27 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 209.52 | 91.89 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 232.49 | 61.78 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 238.61 | 59.90 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 309.09 | 69.22 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 380.96 | 99.21 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 404.56 | 174.46 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 486.66 | 188.15 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 449.53 | 212.42 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 354.01 | 134.92 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 209.52 | 59.90 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 499.25 | 212.42 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 92.34 | 56.58 | 35.76 | 83.93 | 132.37 | 0.00 | 0.00 | 0.00 |
| February | 122.89 | 77.66 | 45.23 | 118.76 | 131.11 | 0.00 | 0.00 | 0.00 |
| March | 148.17 | 86.30 | 61.88 | 154.88 | 100.08 | 0.00 | 0.00 | 0.00 |
| April | 151.95 | 74.10 | 77.85 | 157.40 | 85.99 | 0.00 | 0.00 | 0.00 |
| May | 177.72 | 74.30 | 103.42 | 204.88 | 55.59 | 0.00 | 0.00 | 0.00 |
| June | 216.69 | 113.81 | 102.88 | 285.93 | 36.79 | 0.00 | 0.00 | 0.00 |
| July | 196.84 | 93.68 | 103.16 | 259.87 | 36.34 | 0.00 | 0.00 | 0.00 |
| August | 198.40 | 109.16 | 89.24 | 259.95 | 43.13 | 0.00 | 0.00 | 0.00 |
| September | 165.41 | 89.85 | 75.56 | 203.61 | 62.01 | 0.00 | 0.00 | 0.00 |
| October | 119.97 | 65.85 | 54.13 | 122.86 | 116.44 | 0.00 | 0.00 | 0.00 |
| November | 93.22 | 52.64 | 40.58 | 86.83 | 130.24 | 0.00 | 0.00 | 0.00 |
| December | 80.82 | 46.64 | 34.18 | 69.86 | 151.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 147.13 | 78.34 | 68.79 | 167.62 | 89.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80.82 | 46.64 | 34.18 | 69.86 | 36.34 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 216.69 | 113.81 | 103.42 | 285.93 | 151.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 92.34 | 56.58 | 35.76 | 85.21 | 131.33 | 0.00 | 0.00 | 0.00 |
| February | 122.89 | 77.66 | 45.23 | 120.25 | 135.57 | 0.00 | 0.00 | 0.00 |
| March | 148.17 | 86.30 | 61.88 | 156.98 | 100.49 | 0.00 | 0.00 | 0.00 |
| April | 151.95 | 74.10 | 77.85 | 158.55 | 87.19 | 0.00 | 0.00 | 0.00 |
| May | 177.72 | 74.30 | 103.42 | 209.24 | 50.49 | 0.00 | 0.00 | 0.00 |
| June | 216.69 | 113.81 | 102.88 | 293.76 | 28.84 | 0.00 | 0.00 | 0.00 |
| July | 196.84 | 93.68 | 103.16 | 269.86 | 26.68 | 0.00 | 0.00 | 0.00 |
| August | 198.40 | 109.16 | 89.24 | 268.56 | 31.75 | 0.00 | 0.00 | 0.00 |
| September | 165.41 | 89.85 | 75.56 | 212.18 | 49.31 | 0.00 | 0.00 | 0.00 |
| October | 119.97 | 65.85 | 54.13 | 129.10 | 104.80 | 0.00 | 0.00 | 0.00 |
| November | 93.22 | 52.64 | 40.58 | 90.50 | 121.77 | 0.00 | 0.00 | 0.00 |
| December | 80.82 | 46.64 | 34.18 | 70.54 | 153.60 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 147.13 | 78.34 | 68.79 | 172.31 | 84.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80.82 | 46.64 | 34.18 | 70.54 | 26.68 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 216.69 | 113.81 | 103.42 | 293.76 | 153.60 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 10.07 | 216.86 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 12.96 | 218.65 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 40.19 | 161.05 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 60.26 | 136.91 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 128.19 | 76.73 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 193.44 | 43.89 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 186.39 | 40.77 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 140.22 | 49.00 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 102.57 | 79.72 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 36.94 | 165.13 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 15.29 | 195.05 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.89 | 249.46 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 78.24 | 135.67 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.89 | 40.77 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 193.44 | 249.46 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 9.85 | 220.28 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 12.93 | 222.06 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 40.42 | 163.78 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 60.60 | 139.15 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 127.84 | 78.99 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 195.26 | 43.94 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 188.11 | 40.74 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 142.20 | 48.75 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.99 | 79.89 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 37.11 | 168.33 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 15.41 | 197.63 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.82 | 252.84 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 78.83 | 137.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.82 | 40.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 195.26 | 252.84 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 9.85 | 220.26 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 12.92 | 222.05 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 40.38 | 163.79 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 60.56 | 139.17 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 127.69 | 79.08 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 195.23 | 43.94 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 188.07 | 40.75 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 142.16 | 48.76 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.95 | 79.91 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 37.10 | 168.26 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 15.40 | 197.61 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.82 | 252.83 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 78.80 | 137.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.82 | 40.75 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 195.23 | 252.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 492.59 | 201.73 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 465.05 | 208.59 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 348.39 | 164.96 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 221.59 | 145.27 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 212.21 | 88.76 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 243.77 | 48.57 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 253.00 | 43.94 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 320.76 | 51.58 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 391.00 | 81.86 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 407.53 | 171.02 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 484.05 | 194.79 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 443.37 | 230.05 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 356.29 | 135.53 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 212.21 | 43.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 492.59 | 230.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 492.88 | 201.13 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 465.31 | 207.89 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 348.49 | 164.65 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 221.60 | 145.05 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 211.59 | 89.42 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 243.18 | 49.09 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 252.31 | 44.56 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 320.16 | 52.22 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 390.50 | 82.52 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 407.25 | 171.53 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 484.06 | 194.74 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 443.66 | 229.33 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 356.10 | 135.62 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 211.59 | 44.56 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 492.88 | 229.33 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 487.72 | 207.03 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 459.00 | 215.47 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 342.82 | 171.77 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 215.01 | 155.43 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 204.90 | 96.38 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 240.20 | 50.49 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 250.16 | 45.24 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 318.42 | 52.33 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 389.62 | 81.22 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 406.64 | 168.80 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 481.94 | 194.33 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 440.54 | 231.82 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 352.45 | 138.77 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 204.90 | 45.24 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 487.72 | 231.82 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 98.13 | 62.15 | 35.98 | 90.05 | 150.25 | 0.00 | 0.00 | 0.00 |
| February | 119.15 | 74.05 | 45.10 | 109.48 | 151.01 | 0.00 | 0.00 | 0.00 |
| March | 138.88 | 76.68 | 62.20 | 137.45 | 114.22 | 0.00 | 0.00 | 0.00 |
| April | 130.17 | 54.90 | 75.26 | 123.98 | 99.86 | 0.00 | 0.00 | 0.00 |
| May | 159.58 | 56.23 | 103.35 | 180.23 | 61.24 | 0.00 | 0.00 | 0.00 |
| June | 195.42 | 94.12 | 101.30 | 265.77 | 32.88 | 0.00 | 0.00 | 0.00 |
| July | 158.95 | 58.14 | 100.81 | 217.54 | 29.45 | 0.00 | 0.00 | 0.00 |
| August | 166.34 | 82.30 | 84.04 | 222.82 | 33.95 | 0.00 | 0.00 | 0.00 |
| September | 147.68 | 70.98 | 76.70 | 188.22 | 53.81 | 0.00 | 0.00 | 0.00 |
| October | 123.49 | 70.46 | 53.03 | 131.12 | 113.86 | 0.00 | 0.00 | 0.00 |
| November | 101.48 | 61.56 | 39.93 | 96.01 | 135.45 | 0.00 | 0.00 | 0.00 |
| December | 82.06 | 48.46 | 33.60 | 68.70 | 165.93 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 135.15 | 67.42 | 67.73 | 152.79 | 94.86 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82.06 | 48.46 | 33.60 | 68.70 | 29.45 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 195.42 | 94.12 | 103.35 | 265.77 | 165.93 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 98.13 | 62.15 | 35.98 | 94.87 | 140.71 | 0.00 | 0.00 | 0.00 |
| February | 119.15 | 74.05 | 45.10 | 114.65 | 143.82 | 0.00 | 0.00 | 0.00 |
| March | 138.88 | 76.68 | 62.20 | 141.30 | 110.25 | 0.00 | 0.00 | 0.00 |
| April | 130.17 | 54.90 | 75.26 | 126.82 | 96.83 | 0.00 | 0.00 | 0.00 |
| May | 159.58 | 56.23 | 103.35 | 181.13 | 60.70 | 0.00 | 0.00 | 0.00 |
| June | 195.42 | 94.12 | 101.30 | 266.12 | 32.84 | 0.00 | 0.00 | 0.00 |
| July | 158.95 | 58.14 | 100.81 | 217.97 | 29.33 | 0.00 | 0.00 | 0.00 |
| August | 166.34 | 82.30 | 84.04 | 224.00 | 33.50 | 0.00 | 0.00 | 0.00 |
| September | 147.68 | 70.98 | 76.70 | 190.33 | 52.40 | 0.00 | 0.00 | 0.00 |
| October | 123.49 | 70.46 | 53.03 | 135.16 | 108.50 | 0.00 | 0.00 | 0.00 |
| November | 101.48 | 61.56 | 39.93 | 101.13 | 126.87 | 0.00 | 0.00 | 0.00 |
| December | 82.06 | 48.46 | 33.60 | 72.38 | 159.01 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 135.15 | 67.42 | 67.73 | 155.65 | 90.95 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82.06 | 48.46 | 33.60 | 72.38 | 29.33 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 195.42 | 94.12 | 103.35 | 266.12 | 159.01 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.68 | 227.10 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 11.29 | 229.77 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 35.59 | 174.12 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 54.71 | 149.07 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 117.95 | 87.38 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 191.37 | 45.81 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 185.19 | 42.07 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 139.99 | 49.89 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.08 | 80.00 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 36.58 | 169.02 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.41 | 201.25 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.23 | 257.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 75.87 | 142.25 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.23 | 42.07 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 191.37 | 257.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 487.04 | 206.40 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 458.03 | 214.83 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 341.68 | 171.30 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 213.78 | 155.45 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 204.02 | 96.24 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 239.50 | 50.21 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 249.37 | 45.13 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 317.59 | 52.12 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 388.96 | 80.97 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 406.10 | 168.37 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 481.44 | 193.59 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 440.01 | 231.38 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 351.66 | 138.41 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 204.02 | 45.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 487.04 | 231.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 92.34 | 56.58 | 35.76 | 79.18 | 147.84 | 0.00 | 0.00 | 0.00 |
| February | 122.89 | 77.66 | 45.23 | 113.38 | 150.40 | 0.00 | 0.00 | 0.00 |
| March | 148.17 | 86.30 | 61.88 | 148.46 | 112.34 | 0.00 | 0.00 | 0.00 |
| April | 151.95 | 74.10 | 77.85 | 150.37 | 97.90 | 0.00 | 0.00 | 0.00 |
| May | 177.72 | 74.30 | 103.42 | 200.59 | 57.89 | 0.00 | 0.00 | 0.00 |
| June | 216.69 | 113.81 | 102.88 | 291.26 | 29.99 | 0.00 | 0.00 | 0.00 |
| July | 196.84 | 93.68 | 103.16 | 267.79 | 27.60 | 0.00 | 0.00 | 0.00 |
| August | 198.40 | 109.16 | 89.24 | 266.30 | 32.65 | 0.00 | 0.00 | 0.00 |
| September | 165.41 | 89.85 | 75.56 | 209.54 | 50.73 | 0.00 | 0.00 | 0.00 |
| October | 119.97 | 65.85 | 54.13 | 123.94 | 112.42 | 0.00 | 0.00 | 0.00 |
| November | 93.22 | 52.64 | 40.58 | 84.81 | 134.79 | 0.00 | 0.00 | 0.00 |
| December | 80.82 | 46.64 | 34.18 | 66.23 | 165.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 147.13 | 78.34 | 68.79 | 167.07 | 93.07 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80.82 | 46.64 | 34.18 | 66.23 | 27.60 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 216.69 | 113.81 | 103.42 | 291.26 | 165.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 92.34 | 56.58 | 35.76 | 83.01 | 137.02 | 0.00 | 0.00 | 0.00 |
| February | 122.89 | 77.66 | 45.23 | 117.55 | 141.97 | 0.00 | 0.00 | 0.00 |
| March | 148.17 | 86.30 | 61.88 | 152.14 | 108.17 | 0.00 | 0.00 | 0.00 |
| April | 151.95 | 74.10 | 77.85 | 153.14 | 94.81 | 0.00 | 0.00 | 0.00 |
| May | 177.72 | 74.30 | 103.42 | 201.46 | 57.36 | 0.00 | 0.00 | 0.00 |
| June | 216.69 | 113.81 | 102.88 | 291.61 | 29.92 | 0.00 | 0.00 | 0.00 |
| July | 196.84 | 93.68 | 103.16 | 268.23 | 27.47 | 0.00 | 0.00 | 0.00 |
| August | 198.40 | 109.16 | 89.24 | 267.47 | 32.20 | 0.00 | 0.00 | 0.00 |
| September | 165.41 | 89.85 | 75.56 | 211.60 | 49.40 | 0.00 | 0.00 | 0.00 |
| October | 119.97 | 65.85 | 54.13 | 127.98 | 106.72 | 0.00 | 0.00 | 0.00 |
| November | 93.22 | 52.64 | 40.58 | 88.99 | 125.20 | 0.00 | 0.00 | 0.00 |
| December | 80.82 | 46.64 | 34.18 | 69.18 | 158.08 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 147.13 | 78.34 | 68.79 | 169.60 | 88.75 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80.82 | 46.64 | 34.18 | 69.18 | 27.47 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 216.69 | 113.81 | 103.42 | 291.61 | 158.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.48 | 226.57 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 10.76 | 229.34 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 34.58 | 173.74 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 53.39 | 149.09 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 116.93 | 87.19 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 190.61 | 45.49 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 184.33 | 41.94 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 139.07 | 49.68 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 102.27 | 79.84 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 35.86 | 168.05 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.00 | 200.54 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.09 | 256.68 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 75.14 | 141.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.09 | 41.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 190.61 | 256.68 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.44 | 229.67 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 11.10 | 231.90 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 35.54 | 175.79 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 54.65 | 151.14 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 118.02 | 88.23 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 193.22 | 45.16 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 186.74 | 41.59 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 141.41 | 49.35 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.75 | 80.33 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 36.08 | 172.00 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.13 | 203.78 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.05 | 260.14 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 76.21 | 143.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.05 | 41.59 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 193.22 | 260.14 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.43 | 229.63 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 11.08 | 231.89 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 35.48 | 175.80 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 54.56 | 151.22 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 117.97 | 88.24 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 193.19 | 45.16 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 186.71 | 41.59 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 141.38 | 49.35 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.71 | 80.34 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 36.06 | 171.92 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.11 | 203.75 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.04 | 260.12 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 76.17 | 143.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.04 | 41.59 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 193.19 | 260.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 485.07 | 213.02 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 456.96 | 220.15 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 341.87 | 174.82 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 214.20 | 159.09 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 204.96 | 97.49 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 241.96 | 49.80 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 251.64 | 44.74 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 319.71 | 51.80 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 390.21 | 81.49 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 405.90 | 172.45 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 480.04 | 199.62 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 438.45 | 237.26 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 351.95 | 141.38 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 204.96 | 44.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 485.07 | 237.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 485.05 | 212.99 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 456.92 | 220.12 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 341.82 | 174.83 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 214.14 | 159.15 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 204.91 | 97.50 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 241.93 | 49.79 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 251.61 | 44.74 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 319.68 | 51.80 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 390.19 | 81.48 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 405.89 | 172.45 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 480.03 | 199.57 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 438.43 | 237.24 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 351.92 | 141.37 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 204.91 | 44.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 485.05 | 237.24 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 488.45 | 195.72 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 458.46 | 205.63 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 342.16 | 162.80 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 214.59 | 146.28 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 205.95 | 88.33 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 236.65 | 48.33 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 246.77 | 43.30 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 314.97 | 50.05 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 388.01 | 75.52 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 407.38 | 156.66 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 481.65 | 182.99 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 440.34 | 222.07 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 351.48 | 131.06 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 205.95 | 43.30 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 488.45 | 222.07 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 98.13 | 62.15 | 35.98 | 89.37 | 141.46 | 0.00 | 0.00 | 0.00 |
| February | 119.15 | 74.05 | 45.10 | 108.42 | 143.46 | 0.00 | 0.00 | 0.00 |
| March | 138.88 | 76.68 | 62.20 | 136.41 | 107.56 | 0.00 | 0.00 | 0.00 |
| April | 130.17 | 54.90 | 75.26 | 123.49 | 93.48 | 0.00 | 0.00 | 0.00 |
| May | 159.58 | 56.23 | 103.35 | 180.80 | 55.78 | 0.00 | 0.00 | 0.00 |
| June | 195.42 | 94.12 | 101.30 | 263.34 | 31.36 | 0.00 | 0.00 | 0.00 |
| July | 158.95 | 58.14 | 100.81 | 215.22 | 28.11 | 0.00 | 0.00 | 0.00 |
| August | 166.34 | 82.30 | 84.04 | 220.52 | 32.37 | 0.00 | 0.00 | 0.00 |
| September | 147.68 | 70.98 | 76.70 | 186.92 | 49.69 | 0.00 | 0.00 | 0.00 |
| October | 123.49 | 70.46 | 53.03 | 130.91 | 105.02 | 0.00 | 0.00 | 0.00 |
| November | 101.48 | 61.56 | 39.93 | 95.03 | 126.95 | 0.00 | 0.00 | 0.00 |
| December | 82.06 | 48.46 | 33.60 | 67.92 | 158.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 135.15 | 67.42 | 67.73 | 151.71 | 89.19 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82.06 | 48.46 | 33.60 | 67.92 | 28.11 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 195.42 | 94.12 | 103.35 | 263.34 | 158.55 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 98.13 | 62.15 | 35.98 | 95.11 | 135.45 | 0.00 | 0.00 | 0.00 |
| February | 119.15 | 74.05 | 45.10 | 114.54 | 138.97 | 0.00 | 0.00 | 0.00 |
| March | 138.88 | 76.68 | 62.20 | 141.05 | 105.09 | 0.00 | 0.00 | 0.00 |
| April | 130.17 | 54.90 | 75.26 | 126.32 | 92.23 | 0.00 | 0.00 | 0.00 |
| May | 159.58 | 56.23 | 103.35 | 182.05 | 55.38 | 0.00 | 0.00 | 0.00 |
| June | 195.42 | 94.12 | 101.30 | 263.73 | 31.42 | 0.00 | 0.00 | 0.00 |
| July | 158.95 | 58.14 | 100.81 | 215.77 | 28.07 | 0.00 | 0.00 | 0.00 |
| August | 166.34 | 82.30 | 84.04 | 222.21 | 31.98 | 0.00 | 0.00 | 0.00 |
| September | 147.68 | 70.98 | 76.70 | 190.09 | 48.39 | 0.00 | 0.00 | 0.00 |
| October | 123.49 | 70.46 | 53.03 | 136.02 | 101.63 | 0.00 | 0.00 | 0.00 |
| November | 101.48 | 61.56 | 39.93 | 101.20 | 121.68 | 0.00 | 0.00 | 0.00 |
| December | 82.06 | 48.46 | 33.60 | 72.52 | 153.69 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 135.15 | 67.42 | 67.73 | 155.22 | 86.72 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82.06 | 48.46 | 33.60 | 72.52 | 28.07 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 195.42 | 94.12 | 103.35 | 263.73 | 153.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 9.08 | 219.22 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 11.40 | 222.68 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 35.74 | 166.83 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 54.29 | 142.48 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 120.43 | 80.53 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 188.39 | 44.32 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 182.32 | 40.63 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 137.59 | 47.90 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 102.92 | 74.21 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 38.03 | 158.94 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.76 | 193.65 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.41 | 249.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 75.56 | 136.25 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.41 | 40.63 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 188.39 | 249.00 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 487.42 | 194.64 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 456.95 | 204.49 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 340.34 | 161.68 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 212.62 | 145.59 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 203.98 | 87.69 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 235.29 | 47.78 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 245.41 | 43.00 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 313.50 | 49.53 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 386.55 | 74.89 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 406.12 | 155.74 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 480.65 | 181.97 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 439.49 | 221.36 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 350.06 | 130.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 203.98 | 43.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 487.42 | 221.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 92.34 | 56.58 | 35.76 | 80.15 | 140.66 | 0.00 | 0.00 | 0.00 |
| February | 122.89 | 77.66 | 45.23 | 113.70 | 144.37 | 0.00 | 0.00 | 0.00 |
| March | 148.17 | 86.30 | 61.88 | 148.12 | 106.46 | 0.00 | 0.00 | 0.00 |
| April | 151.95 | 74.10 | 77.85 | 150.13 | 91.88 | 0.00 | 0.00 | 0.00 |
| May | 177.72 | 74.30 | 103.42 | 201.52 | 53.31 | 0.00 | 0.00 | 0.00 |
| June | 216.69 | 113.81 | 102.88 | 288.77 | 28.80 | 0.00 | 0.00 | 0.00 |
| July | 196.84 | 93.68 | 103.16 | 265.37 | 26.48 | 0.00 | 0.00 | 0.00 |
| August | 198.40 | 109.16 | 89.24 | 263.82 | 31.18 | 0.00 | 0.00 | 0.00 |
| September | 165.41 | 89.85 | 75.56 | 208.46 | 47.23 | 0.00 | 0.00 | 0.00 |
| October | 119.97 | 65.85 | 54.13 | 124.19 | 104.35 | 0.00 | 0.00 | 0.00 |
| November | 93.22 | 52.64 | 40.58 | 85.17 | 127.83 | 0.00 | 0.00 | 0.00 |
| December | 80.82 | 46.64 | 34.18 | 66.53 | 159.74 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 147.13 | 78.34 | 68.79 | 166.58 | 88.22 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80.82 | 46.64 | 34.18 | 66.53 | 26.48 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 216.69 | 113.81 | 103.42 | 288.77 | 159.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 92.34 | 56.58 | 35.76 | 83.79 | 132.17 | 0.00 | 0.00 | 0.00 |
| February | 122.89 | 77.66 | 45.23 | 117.78 | 137.42 | 0.00 | 0.00 | 0.00 |
| March | 148.17 | 86.30 | 61.88 | 152.10 | 103.37 | 0.00 | 0.00 | 0.00 |
| April | 151.95 | 74.10 | 77.85 | 152.79 | 90.30 | 0.00 | 0.00 | 0.00 |
| May | 177.72 | 74.30 | 103.42 | 202.62 | 52.86 | 0.00 | 0.00 | 0.00 |
| June | 216.69 | 113.81 | 102.88 | 289.21 | 28.80 | 0.00 | 0.00 | 0.00 |
| July | 196.84 | 93.68 | 103.16 | 265.95 | 26.41 | 0.00 | 0.00 | 0.00 |
| August | 198.40 | 109.16 | 89.24 | 265.49 | 30.79 | 0.00 | 0.00 | 0.00 |
| September | 165.41 | 89.85 | 75.56 | 211.42 | 45.92 | 0.00 | 0.00 | 0.00 |
| October | 119.97 | 65.85 | 54.13 | 128.92 | 100.21 | 0.00 | 0.00 | 0.00 |
| November | 93.22 | 52.64 | 40.58 | 89.45 | 120.35 | 0.00 | 0.00 | 0.00 |
| December | 80.82 | 46.64 | 34.18 | 69.71 | 153.09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 147.13 | 78.34 | 68.79 | 169.34 | 84.86 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80.82 | 46.64 | 34.18 | 69.71 | 26.41 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 216.69 | 113.81 | 103.42 | 289.21 | 153.09 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.70 | 218.36 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 10.49 | 221.79 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 33.82 | 165.76 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 52.30 | 141.66 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 118.23 | 79.90 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 187.04 | 43.70 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 180.93 | 40.28 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 135.99 | 47.39 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 101.16 | 73.67 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 36.45 | 157.44 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 13.95 | 192.49 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.14 | 248.39 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 74.21 | 135.45 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.14 | 40.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 187.04 | 248.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.98 | 221.38 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 11.32 | 224.69 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 35.96 | 168.14 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 54.60 | 144.13 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 120.64 | 82.13 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 190.43 | 44.22 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 184.04 | 40.72 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 139.14 | 48.06 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.85 | 75.19 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 38.41 | 160.31 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.69 | 195.48 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.35 | 252.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 76.15 | 137.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.35 | 40.72 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 190.43 | 252.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.83 | 0.00 | 44.83 | 8.95 | 221.32 | 0.00 | 0.00 | 0.00 |
| February | 56.34 | 0.00 | 56.34 | 11.25 | 224.65 | 0.00 | 0.00 | 0.00 |
| March | 76.69 | 0.01 | 76.68 | 35.80 | 168.09 | 0.00 | 0.00 | 0.00 |
| April | 96.32 | 0.59 | 95.73 | 54.43 | 144.09 | 0.00 | 0.00 | 0.00 |
| May | 131.65 | 4.42 | 127.24 | 120.46 | 82.09 | 0.00 | 0.00 | 0.00 |
| June | 144.01 | 15.78 | 128.23 | 190.36 | 44.19 | 0.00 | 0.00 | 0.00 |
| July | 136.67 | 9.06 | 127.61 | 183.97 | 40.70 | 0.00 | 0.00 | 0.00 |
| August | 109.02 | 2.98 | 106.04 | 139.06 | 48.03 | 0.00 | 0.00 | 0.00 |
| September | 91.27 | 0.06 | 91.21 | 103.73 | 75.16 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 0.00 | 65.31 | 38.28 | 160.21 | 0.00 | 0.00 | 0.00 |
| November | 49.58 | 0.00 | 49.58 | 14.63 | 195.41 | 0.00 | 0.00 | 0.00 |
| December | 41.94 | 0.00 | 41.94 | 7.33 | 252.01 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 2.75 | 84.38 | 76.05 | 137.54 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.94 | 0.00 | 41.94 | 7.33 | 40.70 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 144.01 | 15.78 | 128.23 | 190.36 | 252.01 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 486.99 | 199.31 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 457.28 | 209.06 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 341.62 | 165.42 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 214.27 | 148.84 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 206.10 | 90.23 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 238.71 | 48.35 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 248.49 | 43.49 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 316.41 | 50.26 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 388.60 | 76.76 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 407.06 | 159.75 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 480.59 | 186.61 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 438.91 | 226.13 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 351.46 | 133.27 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 206.10 | 43.49 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 486.99 | 226.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 428.65 | 352.45 | 76.20 | 486.92 | 199.23 | 0.00 | 0.00 | 0.00 |
| February | 406.67 | 323.10 | 83.56 | 457.18 | 208.98 | 0.00 | 0.00 | 0.00 |
| March | 299.62 | 195.70 | 103.92 | 341.49 | 165.35 | 0.00 | 0.00 | 0.00 |
| April | 204.47 | 86.82 | 117.66 | 214.13 | 148.81 | 0.00 | 0.00 | 0.00 |
| May | 180.77 | 33.49 | 147.28 | 205.96 | 90.19 | 0.00 | 0.00 | 0.00 |
| June | 167.04 | 31.17 | 135.87 | 238.63 | 48.32 | 0.00 | 0.00 | 0.00 |
| July | 172.68 | 30.61 | 142.07 | 248.43 | 43.47 | 0.00 | 0.00 | 0.00 |
| August | 220.19 | 91.95 | 128.23 | 316.34 | 50.23 | 0.00 | 0.00 | 0.00 |
| September | 287.73 | 162.40 | 125.33 | 388.53 | 76.72 | 0.00 | 0.00 | 0.00 |
| October | 337.00 | 238.53 | 98.47 | 406.99 | 159.68 | 0.00 | 0.00 | 0.00 |
| November | 413.31 | 329.52 | 83.80 | 480.53 | 186.53 | 0.00 | 0.00 | 0.00 |
| December | 394.55 | 319.27 | 75.28 | 438.85 | 226.08 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 292.06 | 182.10 | 109.96 | 351.37 | 133.22 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 167.04 | 30.61 | 75.28 | 205.96 | 43.47 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 428.65 | 352.45 | 147.28 | 486.92 | 226.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 22.16 | 13.58 | 8.58 | 19.58 | 34.09 | 491.50 | 0.00 | 0.00 |
| February | 29.49 | 18.64 | 10.85 | 27.67 | 35.13 | 112.17 | 0.00 | 0.00 |
| March | 35.55 | 20.71 | 14.85 | 35.86 | 26.69 | 42.67 | 0.00 | 0.00 |
| April | 36.46 | 17.78 | 18.68 | 36.04 | 23.50 | 100.17 | 0.00 | 0.00 |
| May | 42.64 | 17.83 | 24.82 | 47.72 | 14.40 | 208.83 | 0.00 | 0.00 |
| June | 52.00 | 27.31 | 24.69 | 67.94 | 8.21 | 206.67 | 0.00 | 0.00 |
| July | 47.23 | 22.48 | 24.75 | 62.30 | 7.68 | 201.33 | 0.00 | 0.00 |
| August | 47.61 | 26.19 | 21.41 | 62.31 | 8.91 | 255.33 | 0.00 | 0.00 |
| September | 39.69 | 21.56 | 18.13 | 49.60 | 12.81 | 211.00 | 0.00 | 0.00 |
| October | 28.79 | 15.80 | 12.99 | 30.27 | 26.36 | 299.17 | 0.00 | 0.00 |
| November | 22.37 | 12.63 | 9.74 | 20.87 | 31.34 | 414.67 | 0.00 | 0.00 |
| December | 19.39 | 11.19 | 8.20 | 16.27 | 38.69 | 1.83 | 0.00 | 0.00 |
| Annual Sum or Average | 35.30 | 18.80 | 16.51 | 39.76 | 22.25 | 2545.33 | 0.00 | 0.00 |
| Minimum of Months | 19.39 | 11.19 | 8.20 | 16.27 | 7.68 | 1.83 | 0.00 | 0.00 |
| Maximum of Months | 52.00 | 27.31 | 24.82 | 67.94 | 38.69 | 491.50 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 65.99 | 40.44 | 25.56 | 60.96 | 93.01 | 0.00 | 0.00 | 0.00 |
| February | 87.82 | 55.50 | 32.32 | 86.09 | 94.24 | 0.00 | 0.00 | 0.00 |
| March | 105.89 | 61.67 | 44.22 | 111.27 | 72.44 | 0.00 | 0.00 | 0.00 |
| April | 108.59 | 52.96 | 55.63 | 112.51 | 63.18 | 0.00 | 0.00 | 0.00 |
| May | 127.01 | 53.10 | 73.91 | 146.29 | 39.79 | 0.00 | 0.00 | 0.00 |
| June | 154.86 | 81.33 | 73.52 | 202.95 | 24.78 | 0.00 | 0.00 | 0.00 |
| July | 140.67 | 66.94 | 73.72 | 185.57 | 23.62 | 1.17 | 0.00 | 0.00 |
| August | 141.79 | 78.01 | 63.77 | 185.75 | 27.62 | 1.33 | 0.00 | 0.00 |
| September | 118.21 | 64.21 | 54.00 | 146.82 | 40.28 | 0.00 | 0.00 | 0.00 |
| October | 85.74 | 47.06 | 38.68 | 90.16 | 78.51 | 0.00 | 0.00 | 0.00 |
| November | 66.62 | 37.62 | 29.00 | 63.96 | 88.58 | 0.00 | 0.00 | 0.00 |
| December | 57.76 | 33.33 | 24.43 | 50.83 | 106.51 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 105.14 | 55.98 | 49.16 | 120.42 | 62.55 | 2.50 | 0.00 | 0.00 |
| Minimum of Months | 57.76 | 33.33 | 24.43 | 50.83 | 23.62 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 154.86 | 81.33 | 73.91 | 202.95 | 106.51 | 1.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 22.16 | 13.58 | 8.58 | 18.79 | 36.92 | 640.67 | 0.00 | 0.00 |
| February | 29.49 | 18.64 | 10.85 | 27.00 | 37.73 | 452.50 | 0.00 | 0.00 |
| March | 35.55 | 20.71 | 14.85 | 35.16 | 28.87 | 339.17 | 0.00 | 0.00 |
| April | 36.46 | 17.78 | 18.68 | 35.42 | 25.57 | 277.33 | 0.00 | 0.00 |
| May | 42.64 | 17.83 | 24.82 | 46.66 | 15.47 | 344.83 | 0.00 | 0.00 |
| June | 52.00 | 27.31 | 24.69 | 68.09 | 8.44 | 278.83 | 0.00 | 0.00 |
| July | 47.23 | 22.48 | 24.75 | 62.50 | 7.89 | 299.17 | 0.00 | 0.00 |
| August | 47.61 | 26.19 | 21.41 | 62.44 | 9.21 | 327.50 | 0.00 | 0.00 |
| September | 39.69 | 21.56 | 18.13 | 49.15 | 13.68 | 351.67 | 0.00 | 0.00 |
| October | 28.79 | 15.80 | 12.99 | 29.39 | 28.99 | 541.17 | 0.00 | 0.00 |
| November | 22.37 | 12.63 | 9.74 | 20.19 | 33.92 | 584.50 | 0.00 | 0.00 |
| December | 19.39 | 11.19 | 8.20 | 15.70 | 41.68 | 309.50 | 0.00 | 0.00 |
| Annual Sum or Average | 35.30 | 18.80 | 16.51 | 39.26 | 23.96 | 4746.83 | 0.00 | 0.00 |
| Minimum of Months | 19.39 | 11.19 | 8.20 | 15.70 | 7.89 | 277.33 | 0.00 | 0.00 |
| Maximum of Months | 52.00 | 27.31 | 24.82 | 68.09 | 41.68 | 640.67 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.132678E+10 | 0.525937E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.113021E+10 | 0.493803E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.937215E+09 | 0.431279E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.577018E+09 | 0.368551E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.573398E+09 | 0.229149E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.629381E+09 | 0.126146E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.675655E+09 | 0.117595E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.856751E+09 | 0.138842E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.101216E+10 | 0.211726E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.109343E+10 | 0.449300E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.125981E+10 | 0.491899E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.119275E+10 | 0.603513E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.112646E+11 | 0.418774E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.573398E+09 | 0.117595E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.132678E+10 | 0.603513E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.262835E+09 | 0.166469E+09 | 96365673.68 | 0.249403E+09 | 0.379606E+09 |
| February | 0.288243E+09 | 0.179135E+09 | 0.109108E+09 | 0.273877E+09 | 0.344633E+09 |
| March | 0.371983E+09 | 0.205389E+09 | 0.166594E+09 | 0.379613E+09 | 0.286391E+09 |
| April | 0.337395E+09 | 0.142309E+09 | 0.195086E+09 | 0.335032E+09 | 0.237149E+09 |
| May | 0.427422E+09 | 0.150613E+09 | 0.276809E+09 | 0.500084E+09 | 0.145978E+09 |
| June | 0.506519E+09 | 0.243951E+09 | 0.262567E+09 | 0.693859E+09 | 82149728.27 |
| July | 0.425723E+09 | 0.155712E+09 | 0.270011E+09 | 0.586653E+09 | 76543414.34 |
| August | 0.445533E+09 | 0.220435E+09 | 0.225097E+09 | 0.599241E+09 | 89998686.30 |
| September | 0.382793E+09 | 0.183986E+09 | 0.198807E+09 | 0.488752E+09 | 0.140108E+09 |
| October | 0.330756E+09 | 0.188710E+09 | 0.142046E+09 | 0.353258E+09 | 0.302863E+09 |
| November | 0.263047E+09 | 0.159558E+09 | 0.103489E+09 | 0.253249E+09 | 0.341825E+09 |
| December | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.188753E+09 | 0.430834E+09 |
| Annual Sum or Average | 0.426203E+10 | 0.212607E+10 | 0.213596E+10 | 0.490177E+10 | 0.285808E+10 |
| Minimum of Months | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.188753E+09 | 76543414.34 |
| Maximum of Months | 0.506519E+09 | 0.243951E+09 | 0.276809E+09 | 0.693859E+09 | 0.430834E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.262835E+09 | 0.166469E+09 | 96365673.68 | 0.259675E+09 | 0.361079E+09 |
| February | 0.288243E+09 | 0.179135E+09 | 0.109108E+09 | 0.283449E+09 | 0.332141E+09 |
| March | 0.371983E+09 | 0.205389E+09 | 0.166594E+09 | 0.390529E+09 | 0.274019E+09 |
| April | 0.337395E+09 | 0.142309E+09 | 0.195086E+09 | 0.341499E+09 | 0.231155E+09 |
| May | 0.427422E+09 | 0.150613E+09 | 0.276809E+09 | 0.505101E+09 | 0.142087E+09 |
| June | 0.506519E+09 | 0.243951E+09 | 0.262567E+09 | 0.695004E+09 | 81742851.25 |
| July | 0.425723E+09 | 0.155712E+09 | 0.270011E+09 | 0.587974E+09 | 76003208.98 |
| August | 0.445533E+09 | 0.220435E+09 | 0.225097E+09 | 0.602810E+09 | 88167456.41 |
| September | 0.382793E+09 | 0.183986E+09 | 0.198807E+09 | 0.494633E+09 | 0.135272E+09 |
| October | 0.330756E+09 | 0.188710E+09 | 0.142046E+09 | 0.364570E+09 | 0.285329E+09 |
| November | 0.263047E+09 | 0.159558E+09 | 0.103489E+09 | 0.265870E+09 | 0.319621E+09 |
| December | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.197257E+09 | 0.413808E+09 |
| Annual Sum or Average | 0.426203E+10 | 0.212607E+10 | 0.213596E+10 | 0.498837E+10 | 0.274043E+10 |
| Minimum of Months | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.197257E+09 | 76003208.98 |
| Maximum of Months | 0.506519E+09 | 0.243951E+09 | 0.276809E+09 | 0.695004E+09 | 0.413808E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 27254760.55 | 0.581689E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 32150074.56 | 0.529742E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.109420E+09 | 0.432031E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.158269E+09 | 0.354843E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.347234E+09 | 0.205094E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.503565E+09 | 0.114388E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.501763E+09 | 0.109218E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.378142E+09 | 0.131443E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.267816E+09 | 0.206792E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.100273E+09 | 0.444490E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 40362137.14 | 0.506936E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 21385582.57 | 0.668869E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.248763E+10 | 0.428554E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 21385582.57 | 0.109218E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.503565E+09 | 0.668869E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.133719E+10 | 0.501343E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.113913E+10 | 0.458173E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.941954E+09 | 0.408918E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.578646E+09 | 0.353210E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.561168E+09 | 0.246117E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.602607E+09 | 0.160136E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.639083E+09 | 0.160436E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.827859E+09 | 0.185409E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.987445E+09 | 0.257148E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.108357E+10 | 0.467278E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.126143E+10 | 0.487676E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.120402E+10 | 0.568954E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.111641E+11 | 0.425480E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.561168E+09 | 0.160136E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.133719E+10 | 0.568954E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.247334E+09 | 0.151556E+09 | 95778134.24 | 0.224789E+09 | 0.354531E+09 |
| February | 0.297301E+09 | 0.187878E+09 | 0.109422E+09 | 0.287315E+09 | 0.317182E+09 |
| March | 0.396869E+09 | 0.231138E+09 | 0.165730E+09 | 0.414837E+09 | 0.268067E+09 |
| April | 0.393855E+09 | 0.192074E+09 | 0.201781E+09 | 0.407987E+09 | 0.222889E+09 |
| May | 0.476002E+09 | 0.199002E+09 | 0.276999E+09 | 0.548756E+09 | 0.148888E+09 |
| June | 0.561672E+09 | 0.294999E+09 | 0.266672E+09 | 0.741128E+09 | 95364560.28 |
| July | 0.527213E+09 | 0.250901E+09 | 0.276312E+09 | 0.696033E+09 | 97328114.79 |
| August | 0.531397E+09 | 0.292376E+09 | 0.239020E+09 | 0.696249E+09 | 0.115509E+09 |
| September | 0.428743E+09 | 0.232882E+09 | 0.195861E+09 | 0.527745E+09 | 0.160723E+09 |
| October | 0.321335E+09 | 0.176360E+09 | 0.144975E+09 | 0.329076E+09 | 0.311880E+09 |
| November | 0.241629E+09 | 0.136434E+09 | 0.105195E+09 | 0.225075E+09 | 0.337581E+09 |
| December | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.187116E+09 | 0.405248E+09 |
| Annual Sum or Average | 0.463982E+10 | 0.247051E+10 | 0.216930E+10 | 0.528611E+10 | 0.283519E+10 |
| Minimum of Months | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.187116E+09 | 95364560.28 |
| Maximum of Months | 0.561672E+09 | 0.294999E+09 | 0.276999E+09 | 0.741128E+09 | 0.405248E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.247334E+09 | 0.151556E+09 | 95778134.24 | 0.228216E+09 | 0.351762E+09 |
| February | 0.297301E+09 | 0.187878E+09 | 0.109422E+09 | 0.290921E+09 | 0.327982E+09 |
| March | 0.396869E+09 | 0.231138E+09 | 0.165730E+09 | 0.420460E+09 | 0.269164E+09 |
| April | 0.393855E+09 | 0.192074E+09 | 0.201781E+09 | 0.410962E+09 | 0.226003E+09 |
| May | 0.476002E+09 | 0.199002E+09 | 0.276999E+09 | 0.560441E+09 | 0.135226E+09 |
| June | 0.561672E+09 | 0.294999E+09 | 0.266672E+09 | 0.761429E+09 | 74756424.78 |
| July | 0.527213E+09 | 0.250901E+09 | 0.276312E+09 | 0.722805E+09 | 71465292.27 |
| August | 0.531397E+09 | 0.292376E+09 | 0.239020E+09 | 0.719319E+09 | 85049743.48 |
| September | 0.428743E+09 | 0.232882E+09 | 0.195861E+09 | 0.549977E+09 | 0.127812E+09 |
| October | 0.321335E+09 | 0.176360E+09 | 0.144975E+09 | 0.345771E+09 | 0.280704E+09 |
| November | 0.241629E+09 | 0.136434E+09 | 0.105195E+09 | 0.234575E+09 | 0.315632E+09 |
| December | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.188944E+09 | 0.411392E+09 |
| Annual Sum or Average | 0.463982E+10 | 0.247051E+10 | 0.216930E+10 | 0.543382E+10 | 0.267695E+10 |
| Minimum of Months | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.188944E+09 | 71465292.27 |
| Maximum of Months | 0.561672E+09 | 0.294999E+09 | 0.276999E+09 | 0.761429E+09 | 0.411392E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 26968752.73 | 0.580836E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 31349623.54 | 0.528967E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.107634E+09 | 0.431356E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.156188E+09 | 0.354864E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.343351E+09 | 0.205525E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.501401E+09 | 0.113753E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.499230E+09 | 0.109193E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.375566E+09 | 0.131252E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.265852E+09 | 0.206623E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 98939500.78 | 0.442278E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 39637367.69 | 0.505579E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 21135658.87 | 0.668166E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.246725E+10 | 0.427839E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 21135658.87 | 0.109193E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.501401E+09 | 0.668166E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 26392644.04 | 0.589997E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 31288906.85 | 0.537214E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.108256E+09 | 0.438681E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.157074E+09 | 0.360665E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.342398E+09 | 0.211570E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.506121E+09 | 0.113896E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.503841E+09 | 0.109121E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.380870E+09 | 0.130576E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.269534E+09 | 0.207084E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 99395994.85 | 0.450846E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 39935976.47 | 0.512258E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 20950277.10 | 0.677219E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.248606E+10 | 0.433913E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 20950277.10 | 0.109121E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.506121E+09 | 0.677219E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 26383608.20 | 0.589951E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 31257496.15 | 0.537184E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.108163E+09 | 0.438702E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.156960E+09 | 0.360741E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.342013E+09 | 0.211798E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.506033E+09 | 0.113890E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.503738E+09 | 0.109142E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.380764E+09 | 0.130596E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.269437E+09 | 0.207116E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 99366725.33 | 0.450669E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 39907619.93 | 0.512193E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 20941367.93 | 0.677172E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.248496E+10 | 0.433915E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 20941367.93 | 0.109142E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.506033E+09 | 0.677172E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.131934E+10 | 0.540303E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.112504E+10 | 0.504614E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.933132E+09 | 0.441825E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.574362E+09 | 0.376531E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.568372E+09 | 0.237737E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.631860E+09 | 0.125888E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.677638E+09 | 0.117700E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.859113E+09 | 0.138150E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.101347E+10 | 0.212172E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.109152E+10 | 0.458067E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.125467E+10 | 0.504905E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.118752E+10 | 0.616176E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.112360E+11 | 0.427407E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.568372E+09 | 0.117700E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.131934E+10 | 0.616176E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.132014E+10 | 0.538717E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.112568E+10 | 0.502938E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.933394E+09 | 0.440993E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.574399E+09 | 0.375967E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.566714E+09 | 0.239512E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.630332E+09 | 0.127231E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.675785E+09 | 0.119347E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.857528E+09 | 0.139857E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.101217E+10 | 0.213896E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.109077E+10 | 0.459424E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.125468E+10 | 0.504755E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.118831E+10 | 0.614247E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.112299E+11 | 0.427688E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.566714E+09 | 0.119347E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.132014E+10 | 0.614247E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.130632E+10 | 0.554498E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.111041E+10 | 0.521273E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.918217E+09 | 0.460059E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.557294E+09 | 0.402885E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.548797E+09 | 0.258144E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.622599E+09 | 0.130882E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.670035E+09 | 0.121161E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.852867E+09 | 0.140163E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.100989E+10 | 0.210525E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.108915E+10 | 0.452116E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124919E+10 | 0.503708E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117995E+10 | 0.620905E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.111147E+11 | 0.437632E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.548797E+09 | 0.121161E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.130632E+10 | 0.620905E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.262835E+09 | 0.166469E+09 | 96365673.68 | 0.241177E+09 | 0.402435E+09 |
| February | 0.288243E+09 | 0.179135E+09 | 0.109108E+09 | 0.264856E+09 | 0.365315E+09 |
| March | 0.371983E+09 | 0.205389E+09 | 0.166594E+09 | 0.368133E+09 | 0.305935E+09 |
| April | 0.337395E+09 | 0.142309E+09 | 0.195086E+09 | 0.321363E+09 | 0.258830E+09 |
| May | 0.427422E+09 | 0.150613E+09 | 0.276809E+09 | 0.482721E+09 | 0.164026E+09 |
| June | 0.506519E+09 | 0.243951E+09 | 0.262567E+09 | 0.688886E+09 | 85232512.10 |
| July | 0.425723E+09 | 0.155712E+09 | 0.270011E+09 | 0.582649E+09 | 78875368.27 |
| August | 0.445533E+09 | 0.220435E+09 | 0.225097E+09 | 0.596806E+09 | 90942774.70 |
| September | 0.382793E+09 | 0.183986E+09 | 0.198807E+09 | 0.487858E+09 | 0.139463E+09 |
| October | 0.330756E+09 | 0.188710E+09 | 0.142046E+09 | 0.351201E+09 | 0.304968E+09 |
| November | 0.263047E+09 | 0.159558E+09 | 0.103489E+09 | 0.248854E+09 | 0.351096E+09 |
| December | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.183999E+09 | 0.444427E+09 |
| Annual Sum or Average | 0.426203E+10 | 0.212607E+10 | 0.213596E+10 | 0.481850E+10 | 0.299155E+10 |
| Minimum of Months | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.183999E+09 | 78875368.27 |
| Maximum of Months | 0.506519E+09 | 0.243951E+09 | 0.276809E+09 | 0.688886E+09 | 0.444427E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.262835E+09 | 0.166469E+09 | 96365673.68 | 0.254091E+09 | 0.376874E+09 |
| February | 0.288243E+09 | 0.179135E+09 | 0.109108E+09 | 0.277352E+09 | 0.347917E+09 |
| March | 0.371983E+09 | 0.205389E+09 | 0.166594E+09 | 0.378447E+09 | 0.295301E+09 |
| April | 0.337395E+09 | 0.142309E+09 | 0.195086E+09 | 0.328721E+09 | 0.250985E+09 |
| May | 0.427422E+09 | 0.150613E+09 | 0.276809E+09 | 0.485147E+09 | 0.162591E+09 |
| June | 0.506519E+09 | 0.243951E+09 | 0.262567E+09 | 0.689780E+09 | 85121377.28 |
| July | 0.425723E+09 | 0.155712E+09 | 0.270011E+09 | 0.583812E+09 | 78553992.64 |
| August | 0.445533E+09 | 0.220435E+09 | 0.225097E+09 | 0.599948E+09 | 89737546.02 |
| September | 0.382793E+09 | 0.183986E+09 | 0.198807E+09 | 0.493329E+09 | 0.135809E+09 |
| October | 0.330756E+09 | 0.188710E+09 | 0.142046E+09 | 0.362005E+09 | 0.290606E+09 |
| November | 0.263047E+09 | 0.159558E+09 | 0.103489E+09 | 0.262134E+09 | 0.328849E+09 |
| December | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.193863E+09 | 0.425897E+09 |
| Annual Sum or Average | 0.426203E+10 | 0.212607E+10 | 0.213596E+10 | 0.490863E+10 | 0.286824E+10 |
| Minimum of Months | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.193863E+09 | 78553992.64 |
| Maximum of Months | 0.506519E+09 | 0.243951E+09 | 0.276809E+09 | 0.689780E+09 | 0.425897E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 23251215.21 | 0.608254E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 27315111.95 | 0.555858E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 95325188.25 | 0.466358E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.141801E+09 | 0.386393E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.315930E+09 | 0.234041E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.496037E+09 | 0.118752E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.496003E+09 | 0.112679E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.374948E+09 | 0.133627E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.267182E+09 | 0.207350E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 97980937.34 | 0.452708E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 37349669.24 | 0.521630E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 19361965.18 | 0.688422E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.239249E+10 | 0.448607E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 19361965.18 | 0.112679E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.496037E+09 | 0.688422E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.130449E+10 | 0.552819E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110807E+10 | 0.519722E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.915145E+09 | 0.458816E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.554128E+09 | 0.402914E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.546444E+09 | 0.257767E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.620771E+09 | 0.130143E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.667900E+09 | 0.120883E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.850640E+09 | 0.139599E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.100818E+10 | 0.209872E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.108770E+10 | 0.450961E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124790E+10 | 0.501775E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117854E+10 | 0.619725E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110899E+11 | 0.436500E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.546444E+09 | 0.120883E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.130449E+10 | 0.619725E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.247334E+09 | 0.151556E+09 | 95778134.24 | 0.212063E+09 | 0.395967E+09 |
| February | 0.297301E+09 | 0.187878E+09 | 0.109422E+09 | 0.274284E+09 | 0.363854E+09 |
| March | 0.396869E+09 | 0.231138E+09 | 0.165730E+09 | 0.397640E+09 | 0.300896E+09 |
| April | 0.393855E+09 | 0.192074E+09 | 0.201781E+09 | 0.389762E+09 | 0.253751E+09 |
| May | 0.476002E+09 | 0.199002E+09 | 0.276999E+09 | 0.537248E+09 | 0.155062E+09 |
| June | 0.561672E+09 | 0.294999E+09 | 0.266672E+09 | 0.754943E+09 | 77727380.26 |
| July | 0.527213E+09 | 0.250901E+09 | 0.276312E+09 | 0.717261E+09 | 73925919.89 |
| August | 0.531397E+09 | 0.292376E+09 | 0.239020E+09 | 0.713264E+09 | 87451686.04 |
| September | 0.428743E+09 | 0.232882E+09 | 0.195861E+09 | 0.543117E+09 | 0.131492E+09 |
| October | 0.321335E+09 | 0.176360E+09 | 0.144975E+09 | 0.331965E+09 | 0.301109E+09 |
| November | 0.241629E+09 | 0.136434E+09 | 0.105195E+09 | 0.219817E+09 | 0.349383E+09 |
| December | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.177404E+09 | 0.444553E+09 |
| Annual Sum or Average | 0.463982E+10 | 0.247051E+10 | 0.216930E+10 | 0.526877E+10 | 0.293517E+10 |
| Minimum of Months | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.177404E+09 | 73925919.89 |
| Maximum of Months | 0.561672E+09 | 0.294999E+09 | 0.276999E+09 | 0.754943E+09 | 0.444553E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.247334E+09 | 0.151556E+09 | 95778134.24 | 0.222343E+09 | 0.367008E+09 |
| February | 0.297301E+09 | 0.187878E+09 | 0.109422E+09 | 0.284381E+09 | 0.343459E+09 |
| March | 0.396869E+09 | 0.231138E+09 | 0.165730E+09 | 0.407498E+09 | 0.289730E+09 |
| April | 0.393855E+09 | 0.192074E+09 | 0.201781E+09 | 0.396927E+09 | 0.245746E+09 |
| May | 0.476002E+09 | 0.199002E+09 | 0.276999E+09 | 0.539593E+09 | 0.153635E+09 |
| June | 0.561672E+09 | 0.294999E+09 | 0.266672E+09 | 0.755851E+09 | 77553646.63 |
| July | 0.527213E+09 | 0.250901E+09 | 0.276312E+09 | 0.718425E+09 | 73575198.88 |
| August | 0.531397E+09 | 0.292376E+09 | 0.239020E+09 | 0.716398E+09 | 86253487.50 |
| September | 0.428743E+09 | 0.232882E+09 | 0.195861E+09 | 0.548468E+09 | 0.128055E+09 |
| October | 0.321335E+09 | 0.176360E+09 | 0.144975E+09 | 0.342790E+09 | 0.285838E+09 |
| November | 0.241629E+09 | 0.136434E+09 | 0.105195E+09 | 0.230667E+09 | 0.324528E+09 |
| December | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.185280E+09 | 0.423391E+09 |
| Annual Sum or Average | 0.463982E+10 | 0.247051E+10 | 0.216930E+10 | 0.534862E+10 | 0.279877E+10 |
| Minimum of Months | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.185280E+09 | 73575198.88 |
| Maximum of Months | 0.561672E+09 | 0.294999E+09 | 0.276999E+09 | 0.755851E+09 | 0.423391E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 22711940.46 | 0.606844E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 26024545.66 | 0.554827E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 92624519.72 | 0.465353E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.138396E+09 | 0.386442E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.313194E+09 | 0.233524E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.494050E+09 | 0.117910E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.493712E+09 | 0.112320E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.372492E+09 | 0.133070E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.265073E+09 | 0.206958E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 96040169.41 | 0.450092E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 36284262.11 | 0.519809E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 18984519.39 | 0.687491E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.236959E+10 | 0.447464E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 18984519.39 | 0.112320E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.494050E+09 | 0.687491E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 22594593.04 | 0.615141E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 26864257.64 | 0.561020E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 95198990.27 | 0.470828E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.141654E+09 | 0.391752E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.316117E+09 | 0.236319E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.500825E+09 | 0.117066E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.500153E+09 | 0.111394E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.378757E+09 | 0.132173E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.268920E+09 | 0.208220E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 96632238.79 | 0.460685E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 36625671.02 | 0.528201E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 18882211.36 | 0.696765E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.240322E+10 | 0.452956E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 18882211.36 | 0.111394E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.500825E+09 | 0.696765E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 22571480.57 | 0.615053E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 26796411.88 | 0.560996E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 95035267.34 | 0.470861E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.141431E+09 | 0.391962E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.315967E+09 | 0.236347E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.500757E+09 | 0.117044E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.500075E+09 | 0.111393E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.378671E+09 | 0.132167E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.268819E+09 | 0.208234E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 96576558.89 | 0.460478E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 36575316.93 | 0.528123E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 18864185.78 | 0.696706E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.240214E+10 | 0.452936E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 18864185.78 | 0.111393E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.500757E+09 | 0.696706E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.129921E+10 | 0.570554E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110548E+10 | 0.532579E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.915676E+09 | 0.468246E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.555211E+09 | 0.412370E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.548954E+09 | 0.261116E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.627156E+09 | 0.129082E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.673987E+09 | 0.119837E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.856313E+09 | 0.138740E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.101142E+10 | 0.211210E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.108717E+10 | 0.461903E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124426E+10 | 0.517420E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117434E+10 | 0.635478E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110992E+11 | 0.445854E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.548954E+09 | 0.119837E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.129921E+10 | 0.635478E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.129915E+10 | 0.570480E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110539E+10 | 0.532516E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.915518E+09 | 0.468276E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.555043E+09 | 0.412512E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.548826E+09 | 0.261143E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.627090E+09 | 0.129059E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.673914E+09 | 0.119835E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.856238E+09 | 0.138733E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.101137E+10 | 0.211198E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.108713E+10 | 0.461882E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124423E+10 | 0.517285E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117428E+10 | 0.635430E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110982E+11 | 0.445835E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.548826E+09 | 0.119835E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.129915E+10 | 0.635430E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.130826E+10 | 0.524221E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110910E+10 | 0.497451E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.916441E+09 | 0.436054E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.556206E+09 | 0.379160E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.551619E+09 | 0.236576E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.613391E+09 | 0.125266E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.660948E+09 | 0.115979E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.843605E+09 | 0.134043E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.100573E+10 | 0.195756E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.109114E+10 | 0.419606E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124842E+10 | 0.474307E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117940E+10 | 0.594789E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110843E+11 | 0.413321E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.551619E+09 | 0.115979E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.130826E+10 | 0.594789E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.262835E+09 | 0.166469E+09 | 96365673.68 | 0.239371E+09 | 0.378889E+09 |
| February | 0.288243E+09 | 0.179135E+09 | 0.109108E+09 | 0.262288E+09 | 0.347056E+09 |
| March | 0.371983E+09 | 0.205389E+09 | 0.166594E+09 | 0.365371E+09 | 0.288088E+09 |
| April | 0.337395E+09 | 0.142309E+09 | 0.195086E+09 | 0.320093E+09 | 0.242308E+09 |
| May | 0.427422E+09 | 0.150613E+09 | 0.276809E+09 | 0.484247E+09 | 0.149397E+09 |
| June | 0.506519E+09 | 0.243951E+09 | 0.262567E+09 | 0.682576E+09 | 81277375.60 |
| July | 0.425723E+09 | 0.155712E+09 | 0.270011E+09 | 0.576442E+09 | 75281423.08 |
| August | 0.445533E+09 | 0.220435E+09 | 0.225097E+09 | 0.590636E+09 | 86687180.11 |
| September | 0.382793E+09 | 0.183986E+09 | 0.198807E+09 | 0.484491E+09 | 0.128806E+09 |
| October | 0.330756E+09 | 0.188710E+09 | 0.142046E+09 | 0.350619E+09 | 0.281281E+09 |
| November | 0.263047E+09 | 0.159558E+09 | 0.103489E+09 | 0.246314E+09 | 0.329051E+09 |
| December | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.181909E+09 | 0.424662E+09 |
| Annual Sum or Average | 0.426203E+10 | 0.212607E+10 | 0.213596E+10 | 0.478436E+10 | 0.281279E+10 |
| Minimum of Months | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.181909E+09 | 75281423.08 |
| Maximum of Months | 0.506519E+09 | 0.243951E+09 | 0.276809E+09 | 0.682576E+09 | 0.424662E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.262835E+09 | 0.166469E+09 | 96365673.68 | 0.254747E+09 | 0.362779E+09 |
| February | 0.288243E+09 | 0.179135E+09 | 0.109108E+09 | 0.277092E+09 | 0.336191E+09 |
| March | 0.371983E+09 | 0.205389E+09 | 0.166594E+09 | 0.377801E+09 | 0.281483E+09 |
| April | 0.337395E+09 | 0.142309E+09 | 0.195086E+09 | 0.327409E+09 | 0.239068E+09 |
| May | 0.427422E+09 | 0.150613E+09 | 0.276809E+09 | 0.487608E+09 | 0.148339E+09 |
| June | 0.506519E+09 | 0.243951E+09 | 0.262567E+09 | 0.683580E+09 | 81435326.76 |
| July | 0.425723E+09 | 0.155712E+09 | 0.270011E+09 | 0.577919E+09 | 75175541.91 |
| August | 0.445533E+09 | 0.220435E+09 | 0.225097E+09 | 0.595166E+09 | 85653450.50 |
| September | 0.382793E+09 | 0.183986E+09 | 0.198807E+09 | 0.492723E+09 | 0.125436E+09 |
| October | 0.330756E+09 | 0.188710E+09 | 0.142046E+09 | 0.364327E+09 | 0.272207E+09 |
| November | 0.263047E+09 | 0.159558E+09 | 0.103489E+09 | 0.262306E+09 | 0.315397E+09 |
| December | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.194250E+09 | 0.411655E+09 |
| Annual Sum or Average | 0.426203E+10 | 0.212607E+10 | 0.213596E+10 | 0.489493E+10 | 0.273482E+10 |
| Minimum of Months | 0.219782E+09 | 0.129800E+09 | 89981739.54 | 0.194250E+09 | 75175541.91 |
| Maximum of Months | 0.506519E+09 | 0.243951E+09 | 0.276809E+09 | 0.683580E+09 | 0.411655E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 24319246.18 | 0.587151E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 27582108.34 | 0.538705E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 95717691.86 | 0.446843E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.140711E+09 | 0.369321E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.322573E+09 | 0.215687E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.488307E+09 | 0.114865E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.488318E+09 | 0.108834E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.368514E+09 | 0.128299E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.266762E+09 | 0.192363E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.101870E+09 | 0.425717E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 38246672.57 | 0.501932E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 19837917.19 | 0.666909E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.238276E+10 | 0.429663E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 19837917.19 | 0.108834E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.488318E+09 | 0.666909E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.130551E+10 | 0.521322E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110546E+10 | 0.494703E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.911557E+09 | 0.433044E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.551119E+09 | 0.377365E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.546337E+09 | 0.234862E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.609882E+09 | 0.123857E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.657314E+09 | 0.115159E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.839681E+09 | 0.132662E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.100193E+10 | 0.194127E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.108775E+10 | 0.417145E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124584E+10 | 0.471658E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117714E+10 | 0.592892E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110395E+11 | 0.410880E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.546337E+09 | 0.115159E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.130551E+10 | 0.592892E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.247334E+09 | 0.151556E+09 | 95778134.24 | 0.214676E+09 | 0.376732E+09 |
| February | 0.297301E+09 | 0.187878E+09 | 0.109422E+09 | 0.275052E+09 | 0.349253E+09 |
| March | 0.396869E+09 | 0.231138E+09 | 0.165730E+09 | 0.396729E+09 | 0.285129E+09 |
| April | 0.393855E+09 | 0.192074E+09 | 0.201781E+09 | 0.389135E+09 | 0.238151E+09 |
| May | 0.476002E+09 | 0.199002E+09 | 0.276999E+09 | 0.539760E+09 | 0.142778E+09 |
| June | 0.561672E+09 | 0.294999E+09 | 0.266672E+09 | 0.748493E+09 | 74640685.32 |
| July | 0.527213E+09 | 0.250901E+09 | 0.276312E+09 | 0.710777E+09 | 70933649.65 |
| August | 0.531397E+09 | 0.292376E+09 | 0.239020E+09 | 0.706607E+09 | 83523086.71 |
| September | 0.428743E+09 | 0.232882E+09 | 0.195861E+09 | 0.540331E+09 | 0.122432E+09 |
| October | 0.321335E+09 | 0.176360E+09 | 0.144975E+09 | 0.332633E+09 | 0.279499E+09 |
| November | 0.241629E+09 | 0.136434E+09 | 0.105195E+09 | 0.220769E+09 | 0.331328E+09 |
| December | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.178181E+09 | 0.427853E+09 |
| Annual Sum or Average | 0.463982E+10 | 0.247051E+10 | 0.216930E+10 | 0.525314E+10 | 0.278225E+10 |
| Minimum of Months | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.178181E+09 | 70933649.65 |
| Maximum of Months | 0.561672E+09 | 0.294999E+09 | 0.276999E+09 | 0.748493E+09 | 0.427853E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.247334E+09 | 0.151556E+09 | 95778134.24 | 0.224414E+09 | 0.354015E+09 |
| February | 0.297301E+09 | 0.187878E+09 | 0.109422E+09 | 0.284930E+09 | 0.332445E+09 |
| March | 0.396869E+09 | 0.231138E+09 | 0.165730E+09 | 0.407375E+09 | 0.276868E+09 |
| April | 0.393855E+09 | 0.192074E+09 | 0.201781E+09 | 0.396030E+09 | 0.234053E+09 |
| May | 0.476002E+09 | 0.199002E+09 | 0.276999E+09 | 0.542697E+09 | 0.141584E+09 |
| June | 0.561672E+09 | 0.294999E+09 | 0.266672E+09 | 0.749643E+09 | 74644415.46 |
| July | 0.527213E+09 | 0.250901E+09 | 0.276312E+09 | 0.712313E+09 | 70741927.02 |
| August | 0.531397E+09 | 0.292376E+09 | 0.239020E+09 | 0.711082E+09 | 82459395.65 |
| September | 0.428743E+09 | 0.232882E+09 | 0.195861E+09 | 0.548006E+09 | 0.119018E+09 |
| October | 0.321335E+09 | 0.176360E+09 | 0.144975E+09 | 0.345301E+09 | 0.268400E+09 |
| November | 0.241629E+09 | 0.136434E+09 | 0.105195E+09 | 0.231854E+09 | 0.311950E+09 |
| December | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.186721E+09 | 0.410032E+09 |
| Annual Sum or Average | 0.463982E+10 | 0.247051E+10 | 0.216930E+10 | 0.534037E+10 | 0.267621E+10 |
| Minimum of Months | 0.216469E+09 | 0.124910E+09 | 91559208.73 | 0.186721E+09 | 70741927.02 |
| Maximum of Months | 0.561672E+09 | 0.294999E+09 | 0.276999E+09 | 0.749643E+09 | 0.410032E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 23300786.44 | 0.584862E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 25389435.41 | 0.536560E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 90580128.23 | 0.443983E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.135557E+09 | 0.367178E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.316678E+09 | 0.213992E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.484806E+09 | 0.113269E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.484593E+09 | 0.107892E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.364229E+09 | 0.126918E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.262196E+09 | 0.190960E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 97623958.48 | 0.421694E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 36156881.25 | 0.498933E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 19120440.00 | 0.665282E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.234023E+10 | 0.427152E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 19120440.00 | 0.107892E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.484806E+09 | 0.665282E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 24059107.28 | 0.592955E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 27380372.03 | 0.543581E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 96320108.44 | 0.450342E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.141527E+09 | 0.373587E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.323110E+09 | 0.219969E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.493592E+09 | 0.114619E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.492926E+09 | 0.109071E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.372679E+09 | 0.128722E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.269175E+09 | 0.194902E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.102883E+09 | 0.429369E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 38069579.28 | 0.506682E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 19686168.12 | 0.675120E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.240141E+10 | 0.433892E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 19686168.12 | 0.109071E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.493592E+09 | 0.675120E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120064E+09 | 0.00 | 0.120064E+09 | 23978564.15 | 0.592794E+09 |
| February | 0.136302E+09 | 0.00 | 0.136302E+09 | 27217732.78 | 0.543471E+09 |
| March | 0.205412E+09 | 22430.65 | 0.205389E+09 | 95876645.85 | 0.450199E+09 |
| April | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.141088E+09 | 0.373489E+09 |
| May | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.322629E+09 | 0.219880E+09 |
| June | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.493420E+09 | 0.114531E+09 |
| July | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.492757E+09 | 0.109019E+09 |
| August | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.372464E+09 | 0.128654E+09 |
| September | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.268858E+09 | 0.194821E+09 |
| October | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.102519E+09 | 0.429098E+09 |
| November | 0.128516E+09 | 0.00 | 0.128516E+09 | 37908180.84 | 0.506512E+09 |
| December | 0.112335E+09 | 0.00 | 0.112335E+09 | 19632764.37 | 0.674993E+09 |
| Annual Sum or Average | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.239835E+10 | 0.433746E+10 |
| Minimum of Months | 0.112335E+09 | 0.00 | 0.112335E+09 | 19632764.37 | 0.109019E+09 |
| Maximum of Months | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.493420E+09 | 0.674993E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.130436E+10 | 0.533838E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110625E+10 | 0.505766E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.914984E+09 | 0.443070E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.555391E+09 | 0.385806E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.552028E+09 | 0.241677E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.618737E+09 | 0.125329E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.665562E+09 | 0.116490E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.847478E+09 | 0.134617E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.100726E+10 | 0.198953E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.109028E+10 | 0.427873E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124569E+10 | 0.483702E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117557E+10 | 0.605664E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110836E+11 | 0.420278E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.552028E+09 | 0.116490E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.130436E+10 | 0.605664E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.130417E+10 | 0.533614E+09 |
| February | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.110601E+10 | 0.505575E+09 |
| March | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.914656E+09 | 0.442871E+09 |
| April | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.555012E+09 | 0.385713E+09 |
| May | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.551637E+09 | 0.241552E+09 |
| June | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.618541E+09 | 0.125233E+09 |
| July | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.665386E+09 | 0.116434E+09 |
| August | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.847290E+09 | 0.134544E+09 |
| September | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.100706E+10 | 0.198847E+09 |
| October | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.109008E+10 | 0.427700E+09 |
| November | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.124553E+10 | 0.483494E+09 |
| December | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.117542E+10 | 0.605538E+09 |
| Annual Sum or Average | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.110808E+11 | 0.420111E+10 |
| Minimum of Months | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.551637E+09 | 0.116434E+09 |
| Maximum of Months | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.130417E+10 | 0.605538E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 59348719.90 | 36366366.74 | 22982353.17 | 52453189.24 | 91314518.91 |
| February | 71338535.78 | 45082196.02 | 26256339.76 | 66946200.82 | 84989683.58 |
| March | 95230271.16 | 55462573.69 | 39767697.47 | 96038791.73 | 71476840.04 |
| April | 94507050.30 | 46088990.59 | 48418059.71 | 93425318.82 | 60922335.28 |
| May | 0.114219E+09 | 47751451.41 | 66467062.71 | 0.127819E+09 | 38563291.43 |
| June | 0.134775E+09 | 70786311.31 | 63989066.19 | 0.176109E+09 | 21288390.74 |
| July | 0.126507E+09 | 60204798.53 | 66302118.88 | 0.166855E+09 | 20575971.21 |
| August | 0.127511E+09 | 70156926.03 | 57353841.99 | 0.166899E+09 | 23852593.08 |
| September | 0.102879E+09 | 55881089.37 | 46997565.57 | 0.128560E+09 | 33201490.07 |
| October | 77105581.28 | 42318311.41 | 34787269.86 | 81075532.24 | 70603105.44 |
| November | 57979866.92 | 32737958.28 | 25241908.63 | 54094903.11 | 81234454.63 |
| December | 51942696.69 | 29972691.87 | 21970004.82 | 43590485.30 | 0.103631E+09 |
| Annual Sum or Average | 0.111334E+10 | 0.592810E+09 | 0.520533E+09 | 0.125387E+10 | 0.701653E+09 |
| Minimum of Months | 51942696.69 | 29972691.87 | 21970004.82 | 43590485.30 | 20575971.21 |
| Maximum of Months | 0.134775E+09 | 70786311.31 | 66467062.71 | 0.176109E+09 | 0.103631E+09 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.176755E+09 | 0.108308E+09 | 68447167.19 | 0.163279E+09 | 0.249119E+09 |
| February | 0.212464E+09 | 0.134266E+09 | 78197914.04 | 0.208271E+09 | 0.227979E+09 |
| March | 0.283619E+09 | 0.165181E+09 | 0.118438E+09 | 0.298016E+09 | 0.194016E+09 |
| April | 0.281466E+09 | 0.137264E+09 | 0.144201E+09 | 0.291638E+09 | 0.163769E+09 |
| May | 0.340171E+09 | 0.142216E+09 | 0.197955E+09 | 0.391820E+09 | 0.106567E+09 |
| June | 0.401395E+09 | 0.210819E+09 | 0.190575E+09 | 0.526050E+09 | 64241391.16 |
| July | 0.376769E+09 | 0.179305E+09 | 0.197464E+09 | 0.497042E+09 | 63264016.89 |
| August | 0.379759E+09 | 0.208945E+09 | 0.170814E+09 | 0.497524E+09 | 73987431.79 |
| September | 0.306398E+09 | 0.166428E+09 | 0.139970E+09 | 0.380547E+09 | 0.104415E+09 |
| October | 0.229640E+09 | 0.126034E+09 | 0.103605E+09 | 0.241476E+09 | 0.210283E+09 |
| November | 0.172678E+09 | 97501787.05 | 75176685.69 | 0.165777E+09 | 0.229590E+09 |
| December | 0.154698E+09 | 89266135.50 | 65432141.87 | 0.136156E+09 | 0.285267E+09 |
| Annual Sum or Average | 0.331581E+10 | 0.176553E+10 | 0.155028E+10 | 0.379760E+10 | 0.197250E+10 |
| Minimum of Months | 0.154698E+09 | 89266135.50 | 65432141.87 | 0.136156E+09 | 63264016.89 |
| Maximum of Months | 0.401395E+09 | 0.210819E+09 | 0.197955E+09 | 0.526050E+09 | 0.285267E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 59348719.90 | 36366366.74 | 22982353.17 | 50316902.32 | 98876913.63 |
| February | 71338535.78 | 45082196.02 | 26256339.76 | 65309989.06 | 91272143.32 |
| March | 95230271.16 | 55462573.69 | 39767697.47 | 94166076.11 | 77329708.90 |
| April | 94507050.30 | 46088990.59 | 48418059.71 | 91803285.01 | 66274481.45 |
| May | 0.114219E+09 | 47751451.41 | 66467062.71 | 0.124982E+09 | 41444023.58 |
| June | 0.134775E+09 | 70786311.31 | 63989066.19 | 0.176481E+09 | 21870024.63 |
| July | 0.126507E+09 | 60204798.53 | 66302118.88 | 0.167406E+09 | 21135979.84 |
| August | 0.127511E+09 | 70156926.03 | 57353841.99 | 0.167226E+09 | 24657291.86 |
| September | 0.102879E+09 | 55881089.37 | 46997565.57 | 0.127385E+09 | 35456912.44 |
| October | 77105581.28 | 42318311.41 | 34787269.86 | 78727028.21 | 77645201.16 |
| November | 57979866.92 | 32737958.28 | 25241908.63 | 52323302.29 | 87928860.82 |
| December | 51942696.69 | 29972691.87 | 21970004.82 | 42038606.11 | 0.111628E+09 |
| Annual Sum or Average | 0.111334E+10 | 0.592810E+09 | 0.520533E+09 | 0.123817E+10 | 0.755519E+09 |
| Minimum of Months | 51942696.69 | 29972691.87 | 21970004.82 | 42038606.11 | 21135979.84 |
| Maximum of Months | 0.134775E+09 | 70786311.31 | 66467062.71 | 0.176481E+09 | 0.111628E+09 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 577.32 | 326.93 | 526.78 | 414.60 | 112.18 | 0.00 | 0.00 |
| February | 571.82 | 338.00 | 525.81 | 397.15 | 128.66 | 0.00 | 0.00 |
| March | 486.92 | 263.22 | 438.50 | 272.39 | 166.11 | 0.00 | 0.00 |
| April | 349.18 | 230.99 | 334.64 | 141.72 | 192.92 | 0.00 | 0.00 |
| May | 399.56 | 138.82 | 340.35 | 89.72 | 250.63 | 0.00 | 0.00 |
| June | 510.06 | 79.91 | 362.45 | 125.29 | 237.17 | 0.00 | 0.00 |
| July | 471.05 | 72.24 | 331.63 | 88.75 | 242.88 | 0.00 | 0.00 |
| August | 543.03 | 84.86 | 386.53 | 174.25 | 212.28 | 0.00 | 0.00 |
| September | 578.09 | 134.77 | 435.42 | 233.39 | 202.03 | 0.00 | 0.00 |
| October | 537.40 | 278.10 | 460.49 | 308.99 | 151.50 | 0.00 | 0.00 |
| November | 577.38 | 315.29 | 514.80 | 391.08 | 123.72 | 0.00 | 0.00 |
| December | 504.25 | 374.64 | 476.61 | 367.74 | 108.87 | 0.00 | 0.00 |
| Annual Sum or Average | 508.38 | 219.17 | 427.20 | 249.52 | 177.69 | 0.00 | 0.00 |
| Minimum of Months | 349.18 | 72.24 | 331.63 | 88.75 | 108.87 | 0.00 | 0.00 |
| Maximum of Months | 578.09 | 374.64 | 526.78 | 414.60 | 250.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 95.65 | 340.51 | 142.96 | 62.15 | 80.81 | 0.00 | 0.00 |
| February | 119.78 | 345.59 | 175.49 | 74.05 | 101.44 | 0.00 | 0.00 |
| March | 182.28 | 259.23 | 215.57 | 76.69 | 138.88 | 0.00 | 0.00 |
| April | 191.07 | 224.33 | 226.49 | 55.50 | 170.99 | 0.00 | 0.00 |
| May | 316.67 | 128.07 | 291.24 | 60.65 | 230.59 | 0.00 | 0.00 |
| June | 460.51 | 73.76 | 339.43 | 109.90 | 229.53 | 0.00 | 0.00 |
| July | 405.59 | 67.88 | 295.62 | 67.20 | 228.42 | 0.00 | 0.00 |
| August | 365.69 | 81.44 | 275.36 | 85.28 | 190.08 | 0.00 | 0.00 |
| September | 293.53 | 131.35 | 238.95 | 71.04 | 167.91 | 0.00 | 0.00 |
| October | 170.88 | 269.82 | 188.80 | 70.46 | 118.35 | 0.00 | 0.00 |
| November | 110.60 | 311.34 | 151.07 | 61.56 | 89.51 | 0.00 | 0.00 |
| December | 70.71 | 393.31 | 124.00 | 48.46 | 75.54 | 0.00 | 0.00 |
| Annual Sum or Average | 232.48 | 218.21 | 222.28 | 70.17 | 152.11 | 0.00 | 0.00 |
| Minimum of Months | 70.71 | 67.88 | 124.00 | 48.46 | 75.54 | 0.00 | 0.00 |
| Maximum of Months | 460.51 | 393.31 | 339.43 | 109.90 | 230.59 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 574.05 | 310.42 | 520.99 | 409.03 | 111.96 | 0.00 | 0.00 |
| February | 583.01 | 313.88 | 529.56 | 400.77 | 128.79 | 0.00 | 0.00 |
| March | 503.35 | 249.54 | 447.79 | 282.00 | 165.79 | 0.00 | 0.00 |
| April | 376.14 | 217.76 | 356.42 | 160.92 | 195.50 | 0.00 | 0.00 |
| May | 409.14 | 142.22 | 358.49 | 107.79 | 250.70 | 0.00 | 0.00 |
| June | 513.70 | 93.85 | 383.73 | 144.98 | 238.75 | 0.00 | 0.00 |
| July | 494.88 | 92.64 | 369.52 | 124.29 | 245.24 | 0.00 | 0.00 |
| August | 566.12 | 109.44 | 418.59 | 201.11 | 217.47 | 0.00 | 0.00 |
| September | 580.91 | 157.56 | 453.14 | 252.25 | 200.89 | 0.00 | 0.00 |
| October | 524.91 | 288.39 | 456.97 | 304.38 | 152.59 | 0.00 | 0.00 |
| November | 567.26 | 312.14 | 506.53 | 382.15 | 124.38 | 0.00 | 0.00 |
| December | 510.37 | 354.71 | 475.37 | 365.91 | 109.46 | 0.00 | 0.00 |
| Annual Sum or Average | 516.53 | 219.71 | 439.18 | 260.44 | 178.74 | 0.00 | 0.00 |
| Minimum of Months | 376.14 | 92.64 | 356.42 | 107.79 | 109.46 | 0.00 | 0.00 |
| Maximum of Months | 583.01 | 354.71 | 529.56 | 409.03 | 250.70 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 80.33 | 333.25 | 137.17 | 56.58 | 80.59 | 0.00 | 0.00 |
| February | 121.10 | 342.12 | 179.23 | 77.66 | 101.57 | 0.00 | 0.00 |
| March | 190.03 | 254.40 | 224.87 | 86.31 | 138.56 | 0.00 | 0.00 |
| April | 215.10 | 220.39 | 248.27 | 74.70 | 173.58 | 0.00 | 0.00 |
| May | 336.37 | 126.15 | 309.37 | 78.72 | 230.66 | 0.00 | 0.00 |
| June | 486.89 | 72.41 | 360.71 | 129.59 | 231.12 | 0.00 | 0.00 |
| July | 456.05 | 67.25 | 333.51 | 102.74 | 230.77 | 0.00 | 0.00 |
| August | 408.08 | 80.06 | 307.42 | 112.14 | 195.28 | 0.00 | 0.00 |
| September | 311.00 | 125.28 | 256.68 | 89.91 | 166.77 | 0.00 | 0.00 |
| October | 161.14 | 265.03 | 185.29 | 65.85 | 119.44 | 0.00 | 0.00 |
| November | 97.19 | 308.22 | 142.80 | 52.64 | 90.17 | 0.00 | 0.00 |
| December | 64.53 | 389.16 | 122.76 | 46.64 | 76.13 | 0.00 | 0.00 |
| Annual Sum or Average | 244.63 | 214.64 | 234.26 | 81.09 | 153.17 | 0.00 | 0.00 |
| Minimum of Months | 64.53 | 67.25 | 122.76 | 46.64 | 76.13 | 0.00 | 0.00 |
| Maximum of Months | 486.89 | 389.16 | 360.71 | 129.59 | 231.12 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 9.85 | 220.28 | 44.83 | 0.00 | 44.83 | 0.00 | 0.00 |
| February | 12.93 | 222.06 | 56.34 | 0.00 | 56.34 | 0.00 | 0.00 |
| March | 40.42 | 163.78 | 76.69 | 0.01 | 76.68 | 0.00 | 0.00 |
| April | 60.60 | 139.15 | 96.32 | 0.59 | 95.73 | 0.00 | 0.00 |
| May | 127.84 | 78.99 | 131.65 | 4.42 | 127.24 | 0.00 | 0.00 |
| June | 195.26 | 43.94 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
| July | 188.11 | 40.74 | 136.67 | 9.06 | 127.61 | 0.00 | 0.00 |
| August | 142.20 | 48.75 | 109.02 | 2.98 | 106.04 | 0.00 | 0.00 |
| September | 103.99 | 79.89 | 91.27 | 0.06 | 91.21 | 0.00 | 0.00 |
| October | 37.11 | 168.33 | 65.31 | 0.00 | 65.31 | 0.00 | 0.00 |
| November | 15.41 | 197.63 | 49.58 | 0.00 | 49.58 | 0.00 | 0.00 |
| December | 7.82 | 252.84 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Annual Sum or Average | 78.83 | 137.59 | 87.13 | 2.75 | 84.38 | 0.00 | 0.00 |
| Minimum of Months | 7.82 | 40.74 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Maximum of Months | 195.26 | 252.84 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 9.85 | 220.26 | 44.83 | 0.00 | 44.83 | 0.00 | 0.00 |
| February | 12.92 | 222.05 | 56.34 | 0.00 | 56.34 | 0.00 | 0.00 |
| March | 40.38 | 163.79 | 76.69 | 0.01 | 76.68 | 0.00 | 0.00 |
| April | 60.56 | 139.17 | 96.32 | 0.59 | 95.73 | 0.00 | 0.00 |
| May | 127.69 | 79.08 | 131.65 | 4.42 | 127.24 | 0.00 | 0.00 |
| June | 195.23 | 43.94 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
| July | 188.07 | 40.75 | 136.67 | 9.06 | 127.61 | 0.00 | 0.00 |
| August | 142.16 | 48.76 | 109.02 | 2.98 | 106.04 | 0.00 | 0.00 |
| September | 103.95 | 79.91 | 91.27 | 0.06 | 91.21 | 0.00 | 0.00 |
| October | 37.10 | 168.26 | 65.31 | 0.00 | 65.31 | 0.00 | 0.00 |
| November | 15.40 | 197.61 | 49.58 | 0.00 | 49.58 | 0.00 | 0.00 |
| December | 7.82 | 252.83 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Annual Sum or Average | 78.80 | 137.59 | 87.13 | 2.75 | 84.38 | 0.00 | 0.00 |
| Minimum of Months | 7.82 | 40.75 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Maximum of Months | 195.23 | 252.83 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 492.59 | 201.73 | 428.65 | 352.45 | 76.20 | 0.00 | 0.00 |
| February | 465.05 | 208.59 | 406.67 | 323.10 | 83.56 | 0.00 | 0.00 |
| March | 348.39 | 164.96 | 299.62 | 195.70 | 103.92 | 0.00 | 0.00 |
| April | 221.59 | 145.27 | 204.47 | 86.82 | 117.66 | 0.00 | 0.00 |
| May | 212.21 | 88.76 | 180.77 | 33.49 | 147.28 | 0.00 | 0.00 |
| June | 243.77 | 48.57 | 167.04 | 31.17 | 135.87 | 0.00 | 0.00 |
| July | 253.00 | 43.94 | 172.68 | 30.61 | 142.07 | 0.00 | 0.00 |
| August | 320.76 | 51.58 | 220.19 | 91.95 | 128.23 | 0.00 | 0.00 |
| September | 391.00 | 81.86 | 287.73 | 162.40 | 125.33 | 0.00 | 0.00 |
| October | 407.53 | 171.02 | 337.00 | 238.53 | 98.47 | 0.00 | 0.00 |
| November | 484.05 | 194.79 | 413.31 | 329.52 | 83.80 | 0.00 | 0.00 |
| December | 443.37 | 230.05 | 394.55 | 319.27 | 75.28 | 0.00 | 0.00 |
| Annual Sum or Average | 356.29 | 135.53 | 292.06 | 182.10 | 109.96 | 0.00 | 0.00 |
| Minimum of Months | 212.21 | 43.94 | 167.04 | 30.61 | 75.28 | 0.00 | 0.00 |
| Maximum of Months | 492.59 | 230.05 | 428.65 | 352.45 | 147.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 492.88 | 201.13 | 428.65 | 352.45 | 76.20 | 0.00 | 0.00 |
| February | 465.31 | 207.89 | 406.67 | 323.10 | 83.56 | 0.00 | 0.00 |
| March | 348.49 | 164.65 | 299.62 | 195.70 | 103.92 | 0.00 | 0.00 |
| April | 221.60 | 145.05 | 204.47 | 86.82 | 117.66 | 0.00 | 0.00 |
| May | 211.59 | 89.42 | 180.77 | 33.49 | 147.28 | 0.00 | 0.00 |
| June | 243.18 | 49.09 | 167.04 | 31.17 | 135.87 | 0.00 | 0.00 |
| July | 252.31 | 44.56 | 172.68 | 30.61 | 142.07 | 0.00 | 0.00 |
| August | 320.16 | 52.22 | 220.19 | 91.95 | 128.23 | 0.00 | 0.00 |
| September | 390.50 | 82.52 | 287.73 | 162.40 | 125.33 | 0.00 | 0.00 |
| October | 407.25 | 171.53 | 337.00 | 238.53 | 98.47 | 0.00 | 0.00 |
| November | 484.06 | 194.74 | 413.31 | 329.52 | 83.80 | 0.00 | 0.00 |
| December | 443.66 | 229.33 | 394.55 | 319.27 | 75.28 | 0.00 | 0.00 |
| Annual Sum or Average | 356.10 | 135.62 | 292.06 | 182.10 | 109.96 | 0.00 | 0.00 |
| Minimum of Months | 211.59 | 44.56 | 167.04 | 30.61 | 75.28 | 0.00 | 0.00 |
| Maximum of Months | 492.88 | 229.33 | 428.65 | 352.45 | 147.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 565.26 | 344.77 | 526.78 | 414.60 | 112.18 | 0.00 | 0.00 |
| February | 558.74 | 356.74 | 525.81 | 397.15 | 128.66 | 0.00 | 0.00 |
| March | 474.75 | 280.47 | 438.50 | 272.39 | 166.11 | 0.00 | 0.00 |
| April | 335.74 | 252.04 | 334.64 | 141.72 | 192.92 | 0.00 | 0.00 |
| May | 383.61 | 156.11 | 340.35 | 89.72 | 250.63 | 0.00 | 0.00 |
| June | 505.45 | 82.86 | 362.45 | 125.29 | 237.17 | 0.00 | 0.00 |
| July | 467.43 | 74.42 | 331.63 | 88.75 | 242.88 | 0.00 | 0.00 |
| August | 540.64 | 85.68 | 386.53 | 174.25 | 212.28 | 0.00 | 0.00 |
| September | 576.86 | 134.05 | 435.42 | 233.39 | 202.03 | 0.00 | 0.00 |
| October | 535.00 | 279.90 | 460.49 | 308.99 | 151.50 | 0.00 | 0.00 |
| November | 571.09 | 322.92 | 514.80 | 391.08 | 123.72 | 0.00 | 0.00 |
| December | 496.97 | 385.48 | 476.61 | 367.74 | 108.87 | 0.00 | 0.00 |
| Annual Sum or Average | 500.53 | 228.92 | 427.20 | 249.52 | 177.69 | 0.00 | 0.00 |
| Minimum of Months | 335.74 | 74.42 | 331.63 | 88.75 | 108.87 | 0.00 | 0.00 |
| Maximum of Months | 576.86 | 385.48 | 526.78 | 414.60 | 250.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 90.93 | 355.19 | 142.96 | 62.15 | 80.81 | 0.00 | 0.00 |
| February | 114.06 | 361.71 | 175.49 | 74.05 | 101.44 | 0.00 | 0.00 |
| March | 171.65 | 279.13 | 215.57 | 76.69 | 138.88 | 0.00 | 0.00 |
| April | 179.28 | 243.65 | 226.49 | 55.50 | 170.99 | 0.00 | 0.00 |
| May | 297.37 | 146.37 | 291.24 | 60.65 | 230.59 | 0.00 | 0.00 |
| June | 455.49 | 76.65 | 339.43 | 109.90 | 229.53 | 0.00 | 0.00 |
| July | 401.84 | 70.08 | 295.62 | 67.20 | 228.42 | 0.00 | 0.00 |
| August | 363.42 | 82.83 | 275.36 | 85.28 | 190.08 | 0.00 | 0.00 |
| September | 292.76 | 131.75 | 238.95 | 71.04 | 167.91 | 0.00 | 0.00 |
| October | 168.89 | 274.67 | 188.80 | 70.46 | 118.35 | 0.00 | 0.00 |
| November | 107.41 | 319.99 | 151.07 | 61.56 | 89.51 | 0.00 | 0.00 |
| December | 68.14 | 404.57 | 124.00 | 48.46 | 75.54 | 0.00 | 0.00 |
| Annual Sum or Average | 226.50 | 228.18 | 222.28 | 70.17 | 152.11 | 0.00 | 0.00 |
| Minimum of Months | 68.14 | 70.08 | 124.00 | 48.46 | 75.54 | 0.00 | 0.00 |
| Maximum of Months | 455.49 | 404.57 | 339.43 | 109.90 | 230.59 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 554.46 | 342.48 | 520.99 | 409.03 | 111.96 | 0.00 | 0.00 |
| February | 562.21 | 356.04 | 529.56 | 400.77 | 128.79 | 0.00 | 0.00 |
| March | 486.15 | 279.65 | 447.79 | 282.00 | 165.79 | 0.00 | 0.00 |
| April | 358.77 | 247.95 | 356.42 | 160.92 | 195.50 | 0.00 | 0.00 |
| May | 398.75 | 148.28 | 358.49 | 107.79 | 250.70 | 0.00 | 0.00 |
| June | 526.91 | 76.35 | 383.73 | 144.98 | 238.75 | 0.00 | 0.00 |
| July | 514.53 | 70.10 | 369.52 | 124.29 | 245.24 | 0.00 | 0.00 |
| August | 581.82 | 82.69 | 418.59 | 201.11 | 217.47 | 0.00 | 0.00 |
| September | 595.54 | 128.74 | 453.14 | 252.25 | 200.89 | 0.00 | 0.00 |
| October | 527.76 | 278.50 | 456.97 | 304.38 | 152.59 | 0.00 | 0.00 |
| November | 559.19 | 321.32 | 506.53 | 382.15 | 124.38 | 0.00 | 0.00 |
| December | 495.39 | 386.50 | 475.37 | 365.91 | 109.46 | 0.00 | 0.00 |
| Annual Sum or Average | 513.09 | 225.85 | 439.18 | 260.44 | 178.74 | 0.00 | 0.00 |
| Minimum of Months | 358.77 | 70.10 | 356.42 | 107.79 | 109.46 | 0.00 | 0.00 |
| Maximum of Months | 595.54 | 386.50 | 529.56 | 409.03 | 250.70 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 75.51 | 347.61 | 137.17 | 56.58 | 80.59 | 0.00 | 0.00 |
| February | 115.04 | 358.05 | 179.23 | 77.66 | 101.57 | 0.00 | 0.00 |
| March | 178.52 | 273.71 | 224.87 | 86.31 | 138.56 | 0.00 | 0.00 |
| April | 202.10 | 239.47 | 248.27 | 74.70 | 173.58 | 0.00 | 0.00 |
| May | 316.98 | 143.14 | 309.37 | 78.72 | 230.66 | 0.00 | 0.00 |
| June | 481.87 | 75.06 | 360.71 | 129.59 | 231.12 | 0.00 | 0.00 |
| July | 452.33 | 69.18 | 333.51 | 102.74 | 230.77 | 0.00 | 0.00 |
| August | 405.81 | 81.15 | 307.42 | 112.14 | 195.28 | 0.00 | 0.00 |
| September | 310.06 | 125.45 | 256.68 | 89.91 | 166.77 | 0.00 | 0.00 |
| October | 158.78 | 269.71 | 185.29 | 65.85 | 119.44 | 0.00 | 0.00 |
| November | 93.93 | 316.69 | 142.80 | 52.64 | 90.17 | 0.00 | 0.00 |
| December | 61.75 | 400.25 | 122.76 | 46.64 | 76.13 | 0.00 | 0.00 |
| Annual Sum or Average | 238.36 | 224.25 | 234.26 | 81.09 | 153.17 | 0.00 | 0.00 |
| Minimum of Months | 61.75 | 69.18 | 122.76 | 46.64 | 76.13 | 0.00 | 0.00 |
| Maximum of Months | 481.87 | 400.25 | 360.71 | 129.59 | 231.12 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 8.44 | 229.67 | 44.83 | 0.00 | 44.83 | 0.00 | 0.00 |
| February | 11.10 | 231.90 | 56.34 | 0.00 | 56.34 | 0.00 | 0.00 |
| March | 35.54 | 175.79 | 76.69 | 0.01 | 76.68 | 0.00 | 0.00 |
| April | 54.65 | 151.14 | 96.32 | 0.59 | 95.73 | 0.00 | 0.00 |
| May | 118.02 | 88.23 | 131.65 | 4.42 | 127.24 | 0.00 | 0.00 |
| June | 193.22 | 45.16 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
| July | 186.74 | 41.59 | 136.67 | 9.06 | 127.61 | 0.00 | 0.00 |
| August | 141.41 | 49.35 | 109.02 | 2.98 | 106.04 | 0.00 | 0.00 |
| September | 103.75 | 80.33 | 91.27 | 0.06 | 91.21 | 0.00 | 0.00 |
| October | 36.08 | 172.00 | 65.31 | 0.00 | 65.31 | 0.00 | 0.00 |
| November | 14.13 | 203.78 | 49.58 | 0.00 | 49.58 | 0.00 | 0.00 |
| December | 7.05 | 260.14 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Annual Sum or Average | 76.21 | 143.63 | 87.13 | 2.75 | 84.38 | 0.00 | 0.00 |
| Minimum of Months | 7.05 | 41.59 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Maximum of Months | 193.22 | 260.14 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 8.43 | 229.63 | 44.83 | 0.00 | 44.83 | 0.00 | 0.00 |
| February | 11.08 | 231.89 | 56.34 | 0.00 | 56.34 | 0.00 | 0.00 |
| March | 35.48 | 175.80 | 76.69 | 0.01 | 76.68 | 0.00 | 0.00 |
| April | 54.56 | 151.22 | 96.32 | 0.59 | 95.73 | 0.00 | 0.00 |
| May | 117.97 | 88.24 | 131.65 | 4.42 | 127.24 | 0.00 | 0.00 |
| June | 193.19 | 45.16 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
| July | 186.71 | 41.59 | 136.67 | 9.06 | 127.61 | 0.00 | 0.00 |
| August | 141.38 | 49.35 | 109.02 | 2.98 | 106.04 | 0.00 | 0.00 |
| September | 103.71 | 80.34 | 91.27 | 0.06 | 91.21 | 0.00 | 0.00 |
| October | 36.06 | 171.92 | 65.31 | 0.00 | 65.31 | 0.00 | 0.00 |
| November | 14.11 | 203.75 | 49.58 | 0.00 | 49.58 | 0.00 | 0.00 |
| December | 7.04 | 260.12 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Annual Sum or Average | 76.17 | 143.63 | 87.13 | 2.75 | 84.38 | 0.00 | 0.00 |
| Minimum of Months | 7.04 | 41.59 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Maximum of Months | 193.19 | 260.12 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 485.07 | 213.02 | 428.65 | 352.45 | 76.20 | 0.00 | 0.00 |
| February | 456.96 | 220.15 | 406.67 | 323.10 | 83.56 | 0.00 | 0.00 |
| March | 341.87 | 174.82 | 299.62 | 195.70 | 103.92 | 0.00 | 0.00 |
| April | 214.20 | 159.09 | 204.47 | 86.82 | 117.66 | 0.00 | 0.00 |
| May | 204.96 | 97.49 | 180.77 | 33.49 | 147.28 | 0.00 | 0.00 |
| June | 241.96 | 49.80 | 167.04 | 31.17 | 135.87 | 0.00 | 0.00 |
| July | 251.64 | 44.74 | 172.68 | 30.61 | 142.07 | 0.00 | 0.00 |
| August | 319.71 | 51.80 | 220.19 | 91.95 | 128.23 | 0.00 | 0.00 |
| September | 390.21 | 81.49 | 287.73 | 162.40 | 125.33 | 0.00 | 0.00 |
| October | 405.90 | 172.45 | 337.00 | 238.53 | 98.47 | 0.00 | 0.00 |
| November | 480.04 | 199.62 | 413.31 | 329.52 | 83.80 | 0.00 | 0.00 |
| December | 438.45 | 237.26 | 394.55 | 319.27 | 75.28 | 0.00 | 0.00 |
| Annual Sum or Average | 351.95 | 141.38 | 292.06 | 182.10 | 109.96 | 0.00 | 0.00 |
| Minimum of Months | 204.96 | 44.74 | 167.04 | 30.61 | 75.28 | 0.00 | 0.00 |
| Maximum of Months | 485.07 | 237.26 | 428.65 | 352.45 | 147.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 485.05 | 212.99 | 428.65 | 352.45 | 76.20 | 0.00 | 0.00 |
| February | 456.92 | 220.12 | 406.67 | 323.10 | 83.56 | 0.00 | 0.00 |
| March | 341.82 | 174.83 | 299.62 | 195.70 | 103.92 | 0.00 | 0.00 |
| April | 214.14 | 159.15 | 204.47 | 86.82 | 117.66 | 0.00 | 0.00 |
| May | 204.91 | 97.50 | 180.77 | 33.49 | 147.28 | 0.00 | 0.00 |
| June | 241.93 | 49.79 | 167.04 | 31.17 | 135.87 | 0.00 | 0.00 |
| July | 251.61 | 44.74 | 172.68 | 30.61 | 142.07 | 0.00 | 0.00 |
| August | 319.68 | 51.80 | 220.19 | 91.95 | 128.23 | 0.00 | 0.00 |
| September | 390.19 | 81.48 | 287.73 | 162.40 | 125.33 | 0.00 | 0.00 |
| October | 405.89 | 172.45 | 337.00 | 238.53 | 98.47 | 0.00 | 0.00 |
| November | 480.03 | 199.57 | 413.31 | 329.52 | 83.80 | 0.00 | 0.00 |
| December | 438.43 | 237.24 | 394.55 | 319.27 | 75.28 | 0.00 | 0.00 |
| Annual Sum or Average | 351.92 | 141.37 | 292.06 | 182.10 | 109.96 | 0.00 | 0.00 |
| Minimum of Months | 204.91 | 44.74 | 167.04 | 30.61 | 75.28 | 0.00 | 0.00 |
| Maximum of Months | 485.05 | 237.24 | 428.65 | 352.45 | 147.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 566.29 | 325.66 | 526.78 | 414.60 | 112.18 | 0.00 | 0.00 |
| February | 557.80 | 340.01 | 525.81 | 397.15 | 128.66 | 0.00 | 0.00 |
| March | 473.17 | 264.96 | 438.50 | 272.39 | 166.11 | 0.00 | 0.00 |
| April | 334.64 | 236.32 | 334.64 | 141.72 | 192.92 | 0.00 | 0.00 |
| May | 385.13 | 142.49 | 340.35 | 89.72 | 250.63 | 0.00 | 0.00 |
| June | 499.40 | 79.10 | 362.45 | 125.29 | 237.17 | 0.00 | 0.00 |
| July | 461.69 | 71.11 | 331.63 | 88.75 | 242.88 | 0.00 | 0.00 |
| August | 534.81 | 81.74 | 386.53 | 174.25 | 212.28 | 0.00 | 0.00 |
| September | 574.01 | 124.30 | 435.42 | 233.39 | 202.03 | 0.00 | 0.00 |
| October | 535.98 | 259.37 | 460.49 | 308.99 | 151.50 | 0.00 | 0.00 |
| November | 570.52 | 303.78 | 514.80 | 391.08 | 123.72 | 0.00 | 0.00 |
| December | 496.60 | 368.96 | 476.61 | 367.74 | 108.87 | 0.00 | 0.00 |
| Annual Sum or Average | 498.74 | 215.80 | 427.20 | 249.52 | 177.69 | 0.00 | 0.00 |
| Minimum of Months | 334.64 | 71.11 | 331.63 | 88.75 | 108.87 | 0.00 | 0.00 |
| Maximum of Months | 574.01 | 368.96 | 526.78 | 414.60 | 250.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 91.58 | 342.05 | 142.96 | 62.15 | 80.81 | 0.00 | 0.00 |
| February | 113.83 | 349.54 | 175.49 | 74.05 | 101.44 | 0.00 | 0.00 |
| March | 171.09 | 266.22 | 215.57 | 76.69 | 138.88 | 0.00 | 0.00 |
| April | 178.07 | 232.18 | 226.49 | 55.50 | 170.99 | 0.00 | 0.00 |
| May | 300.79 | 134.21 | 291.24 | 60.65 | 230.59 | 0.00 | 0.00 |
| June | 450.32 | 73.94 | 339.43 | 109.90 | 229.53 | 0.00 | 0.00 |
| July | 396.92 | 67.54 | 295.62 | 67.20 | 228.42 | 0.00 | 0.00 |
| August | 359.23 | 79.31 | 275.36 | 85.28 | 190.08 | 0.00 | 0.00 |
| September | 292.30 | 121.90 | 238.95 | 71.04 | 167.91 | 0.00 | 0.00 |
| October | 171.05 | 257.57 | 188.80 | 70.46 | 118.35 | 0.00 | 0.00 |
| November | 107.65 | 307.02 | 151.07 | 61.56 | 89.51 | 0.00 | 0.00 |
| December | 68.47 | 391.23 | 124.00 | 48.46 | 75.54 | 0.00 | 0.00 |
| Annual Sum or Average | 225.67 | 217.86 | 222.28 | 70.17 | 152.11 | 0.00 | 0.00 |
| Minimum of Months | 68.47 | 67.54 | 124.00 | 48.46 | 75.54 | 0.00 | 0.00 |
| Maximum of Months | 450.32 | 391.23 | 339.43 | 109.90 | 230.59 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 555.30 | 323.02 | 520.99 | 409.03 | 111.96 | 0.00 | 0.00 |
| February | 560.80 | 339.01 | 529.56 | 400.77 | 128.79 | 0.00 | 0.00 |
| March | 484.64 | 264.32 | 447.79 | 282.00 | 165.79 | 0.00 | 0.00 |
| April | 357.96 | 232.67 | 356.42 | 160.92 | 195.50 | 0.00 | 0.00 |
| May | 400.78 | 136.27 | 358.49 | 107.79 | 250.70 | 0.00 | 0.00 |
| June | 520.68 | 73.20 | 383.73 | 144.98 | 238.75 | 0.00 | 0.00 |
| July | 508.51 | 67.20 | 369.52 | 124.29 | 245.24 | 0.00 | 0.00 |
| August | 575.53 | 78.93 | 418.59 | 201.11 | 217.47 | 0.00 | 0.00 |
| September | 592.60 | 119.72 | 453.14 | 252.25 | 200.89 | 0.00 | 0.00 |
| October | 528.14 | 257.92 | 456.97 | 304.38 | 152.59 | 0.00 | 0.00 |
| November | 558.17 | 302.14 | 506.53 | 382.15 | 124.38 | 0.00 | 0.00 |
| December | 494.73 | 369.81 | 475.37 | 365.91 | 109.46 | 0.00 | 0.00 |
| Annual Sum or Average | 511.13 | 213.00 | 439.18 | 260.44 | 178.74 | 0.00 | 0.00 |
| Minimum of Months | 357.96 | 67.20 | 356.42 | 107.79 | 109.46 | 0.00 | 0.00 |
| Maximum of Months | 592.60 | 369.81 | 529.56 | 409.03 | 250.70 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 77.19 | 335.24 | 137.17 | 56.58 | 80.59 | 0.00 | 0.00 |
| February | 115.59 | 346.52 | 179.23 | 77.66 | 101.57 | 0.00 | 0.00 |
| March | 178.36 | 261.58 | 224.87 | 86.31 | 138.56 | 0.00 | 0.00 |
| April | 201.15 | 228.02 | 248.27 | 74.70 | 173.58 | 0.00 | 0.00 |
| May | 319.75 | 131.65 | 309.37 | 78.72 | 230.66 | 0.00 | 0.00 |
| June | 475.93 | 72.17 | 360.71 | 129.59 | 231.12 | 0.00 | 0.00 |
| July | 446.67 | 66.49 | 333.51 | 102.74 | 230.77 | 0.00 | 0.00 |
| August | 400.88 | 77.58 | 307.42 | 112.14 | 195.28 | 0.00 | 0.00 |
| September | 309.59 | 116.60 | 256.68 | 89.91 | 166.77 | 0.00 | 0.00 |
| October | 161.01 | 253.29 | 185.29 | 65.85 | 119.44 | 0.00 | 0.00 |
| November | 94.91 | 304.35 | 142.80 | 52.64 | 90.17 | 0.00 | 0.00 |
| December | 62.88 | 387.51 | 122.76 | 46.64 | 76.13 | 0.00 | 0.00 |
| Annual Sum or Average | 237.62 | 214.38 | 234.26 | 81.09 | 153.17 | 0.00 | 0.00 |
| Minimum of Months | 62.88 | 66.49 | 122.76 | 46.64 | 76.13 | 0.00 | 0.00 |
| Maximum of Months | 475.93 | 387.51 | 360.71 | 129.59 | 231.12 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 8.98 | 221.38 | 44.83 | 0.00 | 44.83 | 0.00 | 0.00 |
| February | 11.32 | 224.69 | 56.34 | 0.00 | 56.34 | 0.00 | 0.00 |
| March | 35.96 | 168.14 | 76.69 | 0.01 | 76.68 | 0.00 | 0.00 |
| April | 54.60 | 144.13 | 96.32 | 0.59 | 95.73 | 0.00 | 0.00 |
| May | 120.64 | 82.13 | 131.65 | 4.42 | 127.24 | 0.00 | 0.00 |
| June | 190.43 | 44.22 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
| July | 184.04 | 40.72 | 136.67 | 9.06 | 127.61 | 0.00 | 0.00 |
| August | 139.14 | 48.06 | 109.02 | 2.98 | 106.04 | 0.00 | 0.00 |
| September | 103.85 | 75.19 | 91.27 | 0.06 | 91.21 | 0.00 | 0.00 |
| October | 38.41 | 160.31 | 65.31 | 0.00 | 65.31 | 0.00 | 0.00 |
| November | 14.69 | 195.48 | 49.58 | 0.00 | 49.58 | 0.00 | 0.00 |
| December | 7.35 | 252.06 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Annual Sum or Average | 76.15 | 137.59 | 87.13 | 2.75 | 84.38 | 0.00 | 0.00 |
| Minimum of Months | 7.35 | 40.72 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Maximum of Months | 190.43 | 252.06 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 8.95 | 221.32 | 44.83 | 0.00 | 44.83 | 0.00 | 0.00 |
| February | 11.25 | 224.65 | 56.34 | 0.00 | 56.34 | 0.00 | 0.00 |
| March | 35.80 | 168.09 | 76.69 | 0.01 | 76.68 | 0.00 | 0.00 |
| April | 54.43 | 144.09 | 96.32 | 0.59 | 95.73 | 0.00 | 0.00 |
| May | 120.46 | 82.09 | 131.65 | 4.42 | 127.24 | 0.00 | 0.00 |
| June | 190.36 | 44.19 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
| July | 183.97 | 40.70 | 136.67 | 9.06 | 127.61 | 0.00 | 0.00 |
| August | 139.06 | 48.03 | 109.02 | 2.98 | 106.04 | 0.00 | 0.00 |
| September | 103.73 | 75.16 | 91.27 | 0.06 | 91.21 | 0.00 | 0.00 |
| October | 38.28 | 160.21 | 65.31 | 0.00 | 65.31 | 0.00 | 0.00 |
| November | 14.63 | 195.41 | 49.58 | 0.00 | 49.58 | 0.00 | 0.00 |
| December | 7.33 | 252.01 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Annual Sum or Average | 76.05 | 137.54 | 87.13 | 2.75 | 84.38 | 0.00 | 0.00 |
| Minimum of Months | 7.33 | 40.70 | 41.94 | 0.00 | 41.94 | 0.00 | 0.00 |
| Maximum of Months | 190.36 | 252.01 | 144.01 | 15.78 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 486.99 | 199.31 | 428.65 | 352.45 | 76.20 | 0.00 | 0.00 |
| February | 457.28 | 209.06 | 406.67 | 323.10 | 83.56 | 0.00 | 0.00 |
| March | 341.62 | 165.42 | 299.62 | 195.70 | 103.92 | 0.00 | 0.00 |
| April | 214.27 | 148.84 | 204.47 | 86.82 | 117.66 | 0.00 | 0.00 |
| May | 206.10 | 90.23 | 180.77 | 33.49 | 147.28 | 0.00 | 0.00 |
| June | 238.71 | 48.35 | 167.04 | 31.17 | 135.87 | 0.00 | 0.00 |
| July | 248.49 | 43.49 | 172.68 | 30.61 | 142.07 | 0.00 | 0.00 |
| August | 316.41 | 50.26 | 220.19 | 91.95 | 128.23 | 0.00 | 0.00 |
| September | 388.60 | 76.76 | 287.73 | 162.40 | 125.33 | 0.00 | 0.00 |
| October | 407.06 | 159.75 | 337.00 | 238.53 | 98.47 | 0.00 | 0.00 |
| November | 480.59 | 186.61 | 413.31 | 329.52 | 83.80 | 0.00 | 0.00 |
| December | 438.91 | 226.13 | 394.55 | 319.27 | 75.28 | 0.00 | 0.00 |
| Annual Sum or Average | 351.46 | 133.27 | 292.06 | 182.10 | 109.96 | 0.00 | 0.00 |
| Minimum of Months | 206.10 | 43.49 | 167.04 | 30.61 | 75.28 | 0.00 | 0.00 |
| Maximum of Months | 486.99 | 226.13 | 428.65 | 352.45 | 147.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 486.92 | 199.23 | 428.65 | 352.45 | 76.20 | 0.00 | 0.00 |
| February | 457.18 | 208.98 | 406.67 | 323.10 | 83.56 | 0.00 | 0.00 |
| March | 341.49 | 165.35 | 299.62 | 195.70 | 103.92 | 0.00 | 0.00 |
| April | 214.13 | 148.81 | 204.47 | 86.82 | 117.66 | 0.00 | 0.00 |
| May | 205.96 | 90.19 | 180.77 | 33.49 | 147.28 | 0.00 | 0.00 |
| June | 238.63 | 48.32 | 167.04 | 31.17 | 135.87 | 0.00 | 0.00 |
| July | 248.43 | 43.47 | 172.68 | 30.61 | 142.07 | 0.00 | 0.00 |
| August | 316.34 | 50.23 | 220.19 | 91.95 | 128.23 | 0.00 | 0.00 |
| September | 388.53 | 76.72 | 287.73 | 162.40 | 125.33 | 0.00 | 0.00 |
| October | 406.99 | 159.68 | 337.00 | 238.53 | 98.47 | 0.00 | 0.00 |
| November | 480.53 | 186.53 | 413.31 | 329.52 | 83.80 | 0.00 | 0.00 |
| December | 438.85 | 226.08 | 394.55 | 319.27 | 75.28 | 0.00 | 0.00 |
| Annual Sum or Average | 351.37 | 133.22 | 292.06 | 182.10 | 109.96 | 0.00 | 0.00 |
| Minimum of Months | 205.96 | 43.47 | 167.04 | 30.61 | 75.28 | 0.00 | 0.00 |
| Maximum of Months | 486.92 | 226.08 | 428.65 | 352.45 | 147.28 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 19.58 | 34.09 | 22.16 | 13.58 | 8.58 | 0.00 | 0.00 |
| February | 27.67 | 35.13 | 29.49 | 18.64 | 10.85 | 0.00 | 0.00 |
| March | 35.86 | 26.69 | 35.55 | 20.71 | 14.85 | 0.00 | 0.00 |
| April | 36.04 | 23.50 | 36.46 | 17.78 | 18.68 | 0.00 | 0.00 |
| May | 47.72 | 14.40 | 42.64 | 17.83 | 24.82 | 0.00 | 0.00 |
| June | 67.94 | 8.21 | 52.00 | 27.31 | 24.69 | 0.00 | 0.00 |
| July | 62.30 | 7.68 | 47.23 | 22.48 | 24.75 | 0.00 | 0.00 |
| August | 62.31 | 8.91 | 47.61 | 26.19 | 21.41 | 0.00 | 0.00 |
| September | 49.60 | 12.81 | 39.69 | 21.56 | 18.13 | 0.00 | 0.00 |
| October | 30.27 | 26.36 | 28.79 | 15.80 | 12.99 | 0.00 | 0.00 |
| November | 20.87 | 31.34 | 22.37 | 12.63 | 9.74 | 0.00 | 0.00 |
| December | 16.27 | 38.69 | 19.39 | 11.19 | 8.20 | 0.00 | 0.00 |
| Annual Sum or Average | 39.76 | 22.25 | 35.30 | 18.80 | 16.51 | 0.00 | 0.00 |
| Minimum of Months | 16.27 | 7.68 | 19.39 | 11.19 | 8.20 | 0.00 | 0.00 |
| Maximum of Months | 67.94 | 38.69 | 52.00 | 27.31 | 24.82 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 60.96 | 93.01 | 65.99 | 40.44 | 25.56 | 0.00 | 0.00 |
| February | 86.09 | 94.24 | 87.82 | 55.50 | 32.32 | 0.00 | 0.00 |
| March | 111.27 | 72.44 | 105.89 | 61.67 | 44.22 | 0.00 | 0.00 |
| April | 112.51 | 63.18 | 108.59 | 52.96 | 55.63 | 0.00 | 0.00 |
| May | 146.29 | 39.79 | 127.01 | 53.10 | 73.91 | 0.00 | 0.00 |
| June | 202.95 | 24.78 | 154.86 | 81.33 | 73.52 | 0.00 | 0.00 |
| July | 185.57 | 23.62 | 140.67 | 66.94 | 73.72 | 0.00 | 0.00 |
| August | 185.75 | 27.62 | 141.79 | 78.01 | 63.77 | 0.00 | 0.00 |
| September | 146.82 | 40.28 | 118.21 | 64.21 | 54.00 | 0.00 | 0.00 |
| October | 90.16 | 78.51 | 85.74 | 47.06 | 38.68 | 0.00 | 0.00 |
| November | 63.96 | 88.58 | 66.62 | 37.62 | 29.00 | 0.00 | 0.00 |
| December | 50.83 | 106.51 | 57.76 | 33.33 | 24.43 | 0.00 | 0.00 |
| Annual Sum or Average | 120.42 | 62.55 | 105.14 | 55.98 | 49.16 | 0.00 | 0.00 |
| Minimum of Months | 50.83 | 23.62 | 57.76 | 33.33 | 24.43 | 0.00 | 0.00 |
| Maximum of Months | 202.95 | 106.51 | 154.86 | 81.33 | 73.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 18.79 | 36.92 | 22.16 | 13.58 | 8.58 | 0.00 | 0.00 |
| February | 27.00 | 37.73 | 29.49 | 18.64 | 10.85 | 0.00 | 0.00 |
| March | 35.16 | 28.87 | 35.55 | 20.71 | 14.85 | 0.00 | 0.00 |
| April | 35.42 | 25.57 | 36.46 | 17.78 | 18.68 | 0.00 | 0.00 |
| May | 46.66 | 15.47 | 42.64 | 17.83 | 24.82 | 0.00 | 0.00 |
| June | 68.09 | 8.44 | 52.00 | 27.31 | 24.69 | 0.00 | 0.00 |
| July | 62.50 | 7.89 | 47.23 | 22.48 | 24.75 | 0.00 | 0.00 |
| August | 62.44 | 9.21 | 47.61 | 26.19 | 21.41 | 0.00 | 0.00 |
| September | 49.15 | 13.68 | 39.69 | 21.56 | 18.13 | 0.00 | 0.00 |
| October | 29.39 | 28.99 | 28.79 | 15.80 | 12.99 | 0.00 | 0.00 |
| November | 20.19 | 33.92 | 22.37 | 12.63 | 9.74 | 0.00 | 0.00 |
| December | 15.70 | 41.68 | 19.39 | 11.19 | 8.20 | 0.00 | 0.00 |
| Annual Sum or Average | 39.26 | 23.96 | 35.30 | 18.80 | 16.51 | 0.00 | 0.00 |
| Minimum of Months | 15.70 | 7.89 | 19.39 | 11.19 | 8.20 | 0.00 | 0.00 |
| Maximum of Months | 68.09 | 41.68 | 52.00 | 27.31 | 24.82 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.154629E+10 | 0.875649E+09 | 0.141093E+10 | 0.111047E+10 | 0.300460E+09 | 0.00 | 0.00 |
| February | 0.138334E+10 | 0.817691E+09 | 0.127205E+10 | 0.960788E+09 | 0.311260E+09 | 0.00 | 0.00 |
| March | 0.130416E+10 | 0.705000E+09 | 0.117448E+10 | 0.729557E+09 | 0.444922E+09 | 0.00 | 0.00 |
| April | 0.905069E+09 | 0.598717E+09 | 0.867391E+09 | 0.367341E+09 | 0.500050E+09 | 0.00 | 0.00 |
| May | 0.107017E+10 | 0.371817E+09 | 0.911587E+09 | 0.240302E+09 | 0.671285E+09 | 0.00 | 0.00 |
| June | 0.132207E+10 | 0.207122E+09 | 0.939478E+09 | 0.324739E+09 | 0.614739E+09 | 0.00 | 0.00 |
| July | 0.126166E+10 | 0.193495E+09 | 0.888237E+09 | 0.237697E+09 | 0.650539E+09 | 0.00 | 0.00 |
| August | 0.145444E+10 | 0.227292E+09 | 0.103528E+10 | 0.466716E+09 | 0.568561E+09 | 0.00 | 0.00 |
| September | 0.149840E+10 | 0.349327E+09 | 0.112860E+10 | 0.604937E+09 | 0.523659E+09 | 0.00 | 0.00 |
| October | 0.143938E+10 | 0.744854E+09 | 0.123337E+10 | 0.827591E+09 | 0.405776E+09 | 0.00 | 0.00 |
| November | 0.149657E+10 | 0.817236E+09 | 0.133436E+10 | 0.101367E+10 | 0.320687E+09 | 0.00 | 0.00 |
| December | 0.135059E+10 | 0.100343E+10 | 0.127656E+10 | 0.984945E+09 | 0.291610E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.160321E+11 | 0.691163E+10 | 0.134723E+11 | 0.786875E+10 | 0.560355E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.905069E+09 | 0.193495E+09 | 0.867391E+09 | 0.237697E+09 | 0.291610E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.154629E+10 | 0.100343E+10 | 0.141093E+10 | 0.111047E+10 | 0.671285E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.256178E+09 | 0.912017E+09 | 0.382899E+09 | 0.166469E+09 | 0.216430E+09 | 0.00 | 0.00 |
| February | 0.289765E+09 | 0.836048E+09 | 0.424545E+09 | 0.179135E+09 | 0.245410E+09 | 0.00 | 0.00 |
| March | 0.488217E+09 | 0.694320E+09 | 0.577395E+09 | 0.205412E+09 | 0.371983E+09 | 0.00 | 0.00 |
| April | 0.495244E+09 | 0.581474E+09 | 0.587068E+09 | 0.143850E+09 | 0.443218E+09 | 0.00 | 0.00 |
| May | 0.848173E+09 | 0.343018E+09 | 0.780044E+09 | 0.162445E+09 | 0.617600E+09 | 0.00 | 0.00 |
| June | 0.119363E+10 | 0.191195E+09 | 0.879796E+09 | 0.284850E+09 | 0.594946E+09 | 0.00 | 0.00 |
| July | 0.108633E+10 | 0.181813E+09 | 0.791785E+09 | 0.179979E+09 | 0.611807E+09 | 0.00 | 0.00 |
| August | 0.979467E+09 | 0.218125E+09 | 0.737531E+09 | 0.228417E+09 | 0.509114E+09 | 0.00 | 0.00 |
| September | 0.760838E+09 | 0.340454E+09 | 0.619363E+09 | 0.184141E+09 | 0.435221E+09 | 0.00 | 0.00 |
| October | 0.457696E+09 | 0.722673E+09 | 0.505693E+09 | 0.188710E+09 | 0.316983E+09 | 0.00 | 0.00 |
| November | 0.286672E+09 | 0.806997E+09 | 0.391563E+09 | 0.159558E+09 | 0.232005E+09 | 0.00 | 0.00 |
| December | 0.189402E+09 | 0.105344E+10 | 0.332117E+09 | 0.129800E+09 | 0.202317E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.733161E+10 | 0.688157E+10 | 0.700980E+10 | 0.221276E+10 | 0.479703E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.189402E+09 | 0.181813E+09 | 0.332117E+09 | 0.129800E+09 | 0.202317E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.119363E+10 | 0.105344E+10 | 0.879796E+09 | 0.284850E+09 | 0.617600E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.153753E+10 | 0.831420E+09 | 0.139543E+10 | 0.109556E+10 | 0.299873E+09 | 0.00 | 0.00 |
| February | 0.141043E+10 | 0.759342E+09 | 0.128111E+10 | 0.969532E+09 | 0.311574E+09 | 0.00 | 0.00 |
| March | 0.134817E+10 | 0.668369E+09 | 0.119936E+10 | 0.755306E+09 | 0.444059E+09 | 0.00 | 0.00 |
| April | 0.974955E+09 | 0.564421E+09 | 0.923850E+09 | 0.417106E+09 | 0.506744E+09 | 0.00 | 0.00 |
| May | 0.109584E+10 | 0.380922E+09 | 0.960167E+09 | 0.288692E+09 | 0.671475E+09 | 0.00 | 0.00 |
| June | 0.133150E+10 | 0.243267E+09 | 0.994631E+09 | 0.375787E+09 | 0.618844E+09 | 0.00 | 0.00 |
| July | 0.132548E+10 | 0.248129E+09 | 0.989727E+09 | 0.332887E+09 | 0.656840E+09 | 0.00 | 0.00 |
| August | 0.151630E+10 | 0.293113E+09 | 0.112114E+10 | 0.538657E+09 | 0.582484E+09 | 0.00 | 0.00 |
| September | 0.150571E+10 | 0.408390E+09 | 0.117455E+10 | 0.653834E+09 | 0.520712E+09 | 0.00 | 0.00 |
| October | 0.140592E+10 | 0.772425E+09 | 0.122395E+10 | 0.815241E+09 | 0.408705E+09 | 0.00 | 0.00 |
| November | 0.147033E+10 | 0.809079E+09 | 0.131294E+10 | 0.990545E+09 | 0.322392E+09 | 0.00 | 0.00 |
| December | 0.136699E+10 | 0.950051E+09 | 0.127324E+10 | 0.980055E+09 | 0.293188E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.162892E+11 | 0.692893E+10 | 0.138501E+11 | 0.821320E+10 | 0.563689E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.974955E+09 | 0.243267E+09 | 0.923850E+09 | 0.288692E+09 | 0.293188E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.153753E+10 | 0.950051E+09 | 0.139543E+10 | 0.109556E+10 | 0.671475E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.215154E+09 | 0.892567E+09 | 0.367398E+09 | 0.151556E+09 | 0.215842E+09 | 0.00 | 0.00 |
| February | 0.292969E+09 | 0.827647E+09 | 0.433603E+09 | 0.187878E+09 | 0.245725E+09 | 0.00 | 0.00 |
| March | 0.508968E+09 | 0.681394E+09 | 0.602280E+09 | 0.231161E+09 | 0.371120E+09 | 0.00 | 0.00 |
| April | 0.557543E+09 | 0.571259E+09 | 0.643528E+09 | 0.193616E+09 | 0.449912E+09 | 0.00 | 0.00 |
| May | 0.900924E+09 | 0.337883E+09 | 0.828624E+09 | 0.210834E+09 | 0.617790E+09 | 0.00 | 0.00 |
| June | 0.126201E+10 | 0.187691E+09 | 0.934949E+09 | 0.335898E+09 | 0.599051E+09 | 0.00 | 0.00 |
| July | 0.122149E+10 | 0.180117E+09 | 0.893276E+09 | 0.275169E+09 | 0.618107E+09 | 0.00 | 0.00 |
| August | 0.109301E+10 | 0.214425E+09 | 0.823395E+09 | 0.300358E+09 | 0.523037E+09 | 0.00 | 0.00 |
| September | 0.806109E+09 | 0.324714E+09 | 0.665313E+09 | 0.233038E+09 | 0.432275E+09 | 0.00 | 0.00 |
| October | 0.431594E+09 | 0.709865E+09 | 0.496272E+09 | 0.176360E+09 | 0.319912E+09 | 0.00 | 0.00 |
| November | 0.251918E+09 | 0.798917E+09 | 0.370145E+09 | 0.136434E+09 | 0.233710E+09 | 0.00 | 0.00 |
| December | 0.172839E+09 | 0.104232E+10 | 0.328804E+09 | 0.124910E+09 | 0.203894E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.771453E+10 | 0.676880E+10 | 0.738759E+10 | 0.255721E+10 | 0.483037E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.172839E+09 | 0.180117E+09 | 0.328804E+09 | 0.124910E+09 | 0.203894E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.126201E+10 | 0.104232E+10 | 0.934949E+09 | 0.335898E+09 | 0.618107E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 26392644.04 | 0.589997E+09 | 0.120064E+09 | 0.00 | 0.120064E+09 | 0.00 | 0.00 |
| February | 31288906.85 | 0.537214E+09 | 0.136302E+09 | 0.00 | 0.136302E+09 | 0.00 | 0.00 |
| March | 0.108256E+09 | 0.438681E+09 | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.00 | 0.00 |
| April | 0.157074E+09 | 0.360665E+09 | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.00 | 0.00 |
| May | 0.342398E+09 | 0.211570E+09 | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.00 | 0.00 |
| June | 0.506121E+09 | 0.113896E+09 | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.00 | 0.00 |
| July | 0.503841E+09 | 0.109121E+09 | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.00 | 0.00 |
| August | 0.380870E+09 | 0.130576E+09 | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.00 | 0.00 |
| September | 0.269534E+09 | 0.207084E+09 | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.00 | 0.00 |
| October | 99395994.85 | 0.450846E+09 | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.00 | 0.00 |
| November | 39935976.47 | 0.512258E+09 | 0.128516E+09 | 0.00 | 0.128516E+09 | 0.00 | 0.00 |
| December | 20950277.10 | 0.677219E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.248606E+10 | 0.433913E+10 | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.00 | 0.00 |
| Minimum of Months | 20950277.10 | 0.109121E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.506121E+09 | 0.677219E+09 | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 26383608.20 | 0.589951E+09 | 0.120064E+09 | 0.00 | 0.120064E+09 | 0.00 | 0.00 |
| February | 31257496.15 | 0.537184E+09 | 0.136302E+09 | 0.00 | 0.136302E+09 | 0.00 | 0.00 |
| March | 0.108163E+09 | 0.438702E+09 | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.00 | 0.00 |
| April | 0.156960E+09 | 0.360741E+09 | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.00 | 0.00 |
| May | 0.342013E+09 | 0.211798E+09 | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.00 | 0.00 |
| June | 0.506033E+09 | 0.113890E+09 | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.00 | 0.00 |
| July | 0.503738E+09 | 0.109142E+09 | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.00 | 0.00 |
| August | 0.380764E+09 | 0.130596E+09 | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.00 | 0.00 |
| September | 0.269437E+09 | 0.207116E+09 | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.00 | 0.00 |
| October | 99366725.33 | 0.450669E+09 | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.00 | 0.00 |
| November | 39907619.93 | 0.512193E+09 | 0.128516E+09 | 0.00 | 0.128516E+09 | 0.00 | 0.00 |
| December | 20941367.93 | 0.677172E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.248496E+10 | 0.433915E+10 | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.00 | 0.00 |
| Minimum of Months | 20941367.93 | 0.109142E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.506033E+09 | 0.677172E+09 | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.131934E+10 | 0.540303E+09 | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.00 | 0.00 |
| February | 0.112504E+10 | 0.504614E+09 | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.00 | 0.00 |
| March | 0.933132E+09 | 0.441825E+09 | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.00 | 0.00 |
| April | 0.574362E+09 | 0.376531E+09 | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.00 | 0.00 |
| May | 0.568372E+09 | 0.237737E+09 | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.00 | 0.00 |
| June | 0.631860E+09 | 0.125888E+09 | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.00 | 0.00 |
| July | 0.677638E+09 | 0.117700E+09 | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.00 | 0.00 |
| August | 0.859113E+09 | 0.138150E+09 | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.00 | 0.00 |
| September | 0.101347E+10 | 0.212172E+09 | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.00 | 0.00 |
| October | 0.109152E+10 | 0.458067E+09 | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.00 | 0.00 |
| November | 0.125467E+10 | 0.504905E+09 | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.00 | 0.00 |
| December | 0.118752E+10 | 0.616176E+09 | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.112360E+11 | 0.427407E+10 | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.568372E+09 | 0.117700E+09 | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.131934E+10 | 0.616176E+09 | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.132014E+10 | 0.538717E+09 | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.00 | 0.00 |
| February | 0.112568E+10 | 0.502938E+09 | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.00 | 0.00 |
| March | 0.933394E+09 | 0.440993E+09 | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.00 | 0.00 |
| April | 0.574399E+09 | 0.375967E+09 | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.00 | 0.00 |
| May | 0.566714E+09 | 0.239512E+09 | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.00 | 0.00 |
| June | 0.630332E+09 | 0.127231E+09 | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.00 | 0.00 |
| July | 0.675785E+09 | 0.119347E+09 | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.00 | 0.00 |
| August | 0.857528E+09 | 0.139857E+09 | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.00 | 0.00 |
| September | 0.101217E+10 | 0.213896E+09 | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.00 | 0.00 |
| October | 0.109077E+10 | 0.459424E+09 | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.00 | 0.00 |
| November | 0.125468E+10 | 0.504755E+09 | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.00 | 0.00 |
| December | 0.118831E+10 | 0.614247E+09 | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.112299E+11 | 0.427688E+10 | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.566714E+09 | 0.119347E+09 | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.132014E+10 | 0.614247E+09 | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.151398E+10 | 0.923420E+09 | 0.141093E+10 | 0.111047E+10 | 0.300460E+09 | 0.00 | 0.00 |
| February | 0.135169E+10 | 0.863017E+09 | 0.127205E+10 | 0.960788E+09 | 0.311260E+09 | 0.00 | 0.00 |
| March | 0.127157E+10 | 0.751209E+09 | 0.117448E+10 | 0.729557E+09 | 0.444922E+09 | 0.00 | 0.00 |
| April | 0.870240E+09 | 0.653298E+09 | 0.867391E+09 | 0.367341E+09 | 0.500050E+09 | 0.00 | 0.00 |
| May | 0.102747E+10 | 0.418124E+09 | 0.911587E+09 | 0.240302E+09 | 0.671285E+09 | 0.00 | 0.00 |
| June | 0.131014E+10 | 0.214767E+09 | 0.939478E+09 | 0.324739E+09 | 0.614739E+09 | 0.00 | 0.00 |
| July | 0.125197E+10 | 0.199325E+09 | 0.888237E+09 | 0.237697E+09 | 0.650539E+09 | 0.00 | 0.00 |
| August | 0.144805E+10 | 0.229481E+09 | 0.103528E+10 | 0.466716E+09 | 0.568561E+09 | 0.00 | 0.00 |
| September | 0.149522E+10 | 0.347458E+09 | 0.112860E+10 | 0.604937E+09 | 0.523659E+09 | 0.00 | 0.00 |
| October | 0.143294E+10 | 0.749672E+09 | 0.123337E+10 | 0.827591E+09 | 0.405776E+09 | 0.00 | 0.00 |
| November | 0.148025E+10 | 0.837019E+09 | 0.133436E+10 | 0.101367E+10 | 0.320687E+09 | 0.00 | 0.00 |
| December | 0.133108E+10 | 0.103246E+10 | 0.127656E+10 | 0.984945E+09 | 0.291610E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.157846E+11 | 0.721925E+10 | 0.134723E+11 | 0.786875E+10 | 0.560355E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.870240E+09 | 0.199325E+09 | 0.867391E+09 | 0.237697E+09 | 0.291610E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.151398E+10 | 0.103246E+10 | 0.141093E+10 | 0.111047E+10 | 0.671285E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.243548E+09 | 0.951334E+09 | 0.382899E+09 | 0.166469E+09 | 0.216430E+09 | 0.00 | 0.00 |
| February | 0.275930E+09 | 0.875038E+09 | 0.424545E+09 | 0.179135E+09 | 0.245410E+09 | 0.00 | 0.00 |
| March | 0.459743E+09 | 0.747630E+09 | 0.577395E+09 | 0.205412E+09 | 0.371983E+09 | 0.00 | 0.00 |
| April | 0.464696E+09 | 0.631552E+09 | 0.587068E+09 | 0.143850E+09 | 0.443218E+09 | 0.00 | 0.00 |
| May | 0.796472E+09 | 0.392027E+09 | 0.780044E+09 | 0.162445E+09 | 0.617600E+09 | 0.00 | 0.00 |
| June | 0.118062E+10 | 0.198678E+09 | 0.879796E+09 | 0.284850E+09 | 0.594946E+09 | 0.00 | 0.00 |
| July | 0.107628E+10 | 0.187698E+09 | 0.791785E+09 | 0.179979E+09 | 0.611807E+09 | 0.00 | 0.00 |
| August | 0.973374E+09 | 0.221842E+09 | 0.737531E+09 | 0.228417E+09 | 0.509114E+09 | 0.00 | 0.00 |
| September | 0.758844E+09 | 0.341493E+09 | 0.619363E+09 | 0.184141E+09 | 0.435221E+09 | 0.00 | 0.00 |
| October | 0.452342E+09 | 0.735670E+09 | 0.505693E+09 | 0.188710E+09 | 0.316983E+09 | 0.00 | 0.00 |
| November | 0.278415E+09 | 0.829411E+09 | 0.391563E+09 | 0.159558E+09 | 0.232005E+09 | 0.00 | 0.00 |
| December | 0.182508E+09 | 0.108360E+10 | 0.332117E+09 | 0.129800E+09 | 0.202317E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.714278E+10 | 0.719597E+10 | 0.700980E+10 | 0.221276E+10 | 0.479703E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.182508E+09 | 0.187698E+09 | 0.332117E+09 | 0.129800E+09 | 0.202317E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.118062E+10 | 0.108360E+10 | 0.879796E+09 | 0.284850E+09 | 0.617600E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.148508E+10 | 0.917306E+09 | 0.139543E+10 | 0.109556E+10 | 0.299873E+09 | 0.00 | 0.00 |
| February | 0.136010E+10 | 0.861327E+09 | 0.128111E+10 | 0.969532E+09 | 0.311574E+09 | 0.00 | 0.00 |
| March | 0.130210E+10 | 0.749024E+09 | 0.119936E+10 | 0.755306E+09 | 0.444059E+09 | 0.00 | 0.00 |
| April | 0.929920E+09 | 0.642694E+09 | 0.923850E+09 | 0.417106E+09 | 0.506744E+09 | 0.00 | 0.00 |
| May | 0.106801E+10 | 0.397143E+09 | 0.960167E+09 | 0.288692E+09 | 0.671475E+09 | 0.00 | 0.00 |
| June | 0.136575E+10 | 0.197904E+09 | 0.994631E+09 | 0.375787E+09 | 0.618844E+09 | 0.00 | 0.00 |
| July | 0.137812E+10 | 0.187769E+09 | 0.989727E+09 | 0.332887E+09 | 0.656840E+09 | 0.00 | 0.00 |
| August | 0.155833E+10 | 0.221482E+09 | 0.112114E+10 | 0.538657E+09 | 0.582484E+09 | 0.00 | 0.00 |
| September | 0.154363E+10 | 0.333697E+09 | 0.117455E+10 | 0.653834E+09 | 0.520712E+09 | 0.00 | 0.00 |
| October | 0.141355E+10 | 0.745947E+09 | 0.122395E+10 | 0.815241E+09 | 0.408705E+09 | 0.00 | 0.00 |
| November | 0.144942E+10 | 0.832856E+09 | 0.131294E+10 | 0.990545E+09 | 0.322392E+09 | 0.00 | 0.00 |
| December | 0.132686E+10 | 0.103520E+10 | 0.127324E+10 | 0.980055E+09 | 0.293188E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.161809E+11 | 0.712234E+10 | 0.138501E+11 | 0.821320E+10 | 0.563689E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.929920E+09 | 0.187769E+09 | 0.923850E+09 | 0.288692E+09 | 0.293188E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.155833E+10 | 0.103520E+10 | 0.139543E+10 | 0.109556E+10 | 0.671475E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.202243E+09 | 0.931039E+09 | 0.367398E+09 | 0.151556E+09 | 0.215842E+09 | 0.00 | 0.00 |
| February | 0.278303E+09 | 0.866183E+09 | 0.433603E+09 | 0.187878E+09 | 0.245725E+09 | 0.00 | 0.00 |
| March | 0.478150E+09 | 0.733111E+09 | 0.602280E+09 | 0.231161E+09 | 0.371120E+09 | 0.00 | 0.00 |
| April | 0.523852E+09 | 0.620716E+09 | 0.643528E+09 | 0.193616E+09 | 0.449912E+09 | 0.00 | 0.00 |
| May | 0.849001E+09 | 0.383373E+09 | 0.828624E+09 | 0.210834E+09 | 0.617790E+09 | 0.00 | 0.00 |
| June | 0.124900E+10 | 0.194565E+09 | 0.934949E+09 | 0.335898E+09 | 0.599051E+09 | 0.00 | 0.00 |
| July | 0.121152E+10 | 0.185280E+09 | 0.893276E+09 | 0.275169E+09 | 0.618107E+09 | 0.00 | 0.00 |
| August | 0.108692E+10 | 0.217357E+09 | 0.823395E+09 | 0.300358E+09 | 0.523037E+09 | 0.00 | 0.00 |
| September | 0.803687E+09 | 0.325159E+09 | 0.665313E+09 | 0.233038E+09 | 0.432275E+09 | 0.00 | 0.00 |
| October | 0.425284E+09 | 0.722384E+09 | 0.496272E+09 | 0.176360E+09 | 0.319912E+09 | 0.00 | 0.00 |
| November | 0.243468E+09 | 0.820855E+09 | 0.370145E+09 | 0.136434E+09 | 0.233710E+09 | 0.00 | 0.00 |
| December | 0.165399E+09 | 0.107202E+10 | 0.328804E+09 | 0.124910E+09 | 0.203894E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.751683E+10 | 0.707204E+10 | 0.738759E+10 | 0.255721E+10 | 0.483037E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.165399E+09 | 0.185280E+09 | 0.328804E+09 | 0.124910E+09 | 0.203894E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.124900E+10 | 0.107202E+10 | 0.934949E+09 | 0.335898E+09 | 0.618107E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 22594593.04 | 0.615141E+09 | 0.120064E+09 | 0.00 | 0.120064E+09 | 0.00 | 0.00 |
| February | 26864257.64 | 0.561020E+09 | 0.136302E+09 | 0.00 | 0.136302E+09 | 0.00 | 0.00 |
| March | 95198990.27 | 0.470828E+09 | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.00 | 0.00 |
| April | 0.141654E+09 | 0.391752E+09 | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.00 | 0.00 |
| May | 0.316117E+09 | 0.236319E+09 | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.00 | 0.00 |
| June | 0.500825E+09 | 0.117066E+09 | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.00 | 0.00 |
| July | 0.500153E+09 | 0.111394E+09 | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.00 | 0.00 |
| August | 0.378757E+09 | 0.132173E+09 | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.00 | 0.00 |
| September | 0.268920E+09 | 0.208220E+09 | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.00 | 0.00 |
| October | 96632238.79 | 0.460685E+09 | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.00 | 0.00 |
| November | 36625671.02 | 0.528201E+09 | 0.128516E+09 | 0.00 | 0.128516E+09 | 0.00 | 0.00 |
| December | 18882211.36 | 0.696765E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.240322E+10 | 0.452956E+10 | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.00 | 0.00 |
| Minimum of Months | 18882211.36 | 0.111394E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.500825E+09 | 0.696765E+09 | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 22571480.57 | 0.615053E+09 | 0.120064E+09 | 0.00 | 0.120064E+09 | 0.00 | 0.00 |
| February | 26796411.88 | 0.560996E+09 | 0.136302E+09 | 0.00 | 0.136302E+09 | 0.00 | 0.00 |
| March | 95035267.34 | 0.470861E+09 | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.00 | 0.00 |
| April | 0.141431E+09 | 0.391962E+09 | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.00 | 0.00 |
| May | 0.315967E+09 | 0.236347E+09 | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.00 | 0.00 |
| June | 0.500757E+09 | 0.117044E+09 | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.00 | 0.00 |
| July | 0.500075E+09 | 0.111393E+09 | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.00 | 0.00 |
| August | 0.378671E+09 | 0.132167E+09 | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.00 | 0.00 |
| September | 0.268819E+09 | 0.208234E+09 | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.00 | 0.00 |
| October | 96576558.89 | 0.460478E+09 | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.00 | 0.00 |
| November | 36575316.93 | 0.528123E+09 | 0.128516E+09 | 0.00 | 0.128516E+09 | 0.00 | 0.00 |
| December | 18864185.78 | 0.696706E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.240214E+10 | 0.452936E+10 | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.00 | 0.00 |
| Minimum of Months | 18864185.78 | 0.111393E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.500757E+09 | 0.696706E+09 | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.129921E+10 | 0.570554E+09 | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.00 | 0.00 |
| February | 0.110548E+10 | 0.532579E+09 | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.00 | 0.00 |
| March | 0.915676E+09 | 0.468246E+09 | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.00 | 0.00 |
| April | 0.555211E+09 | 0.412370E+09 | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.00 | 0.00 |
| May | 0.548954E+09 | 0.261116E+09 | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.00 | 0.00 |
| June | 0.627156E+09 | 0.129082E+09 | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.00 | 0.00 |
| July | 0.673987E+09 | 0.119837E+09 | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.00 | 0.00 |
| August | 0.856313E+09 | 0.138740E+09 | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.00 | 0.00 |
| September | 0.101142E+10 | 0.211210E+09 | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.00 | 0.00 |
| October | 0.108717E+10 | 0.461903E+09 | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.00 | 0.00 |
| November | 0.124426E+10 | 0.517420E+09 | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.00 | 0.00 |
| December | 0.117434E+10 | 0.635478E+09 | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.110992E+11 | 0.445854E+10 | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.548954E+09 | 0.119837E+09 | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.129921E+10 | 0.635478E+09 | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.129915E+10 | 0.570480E+09 | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.00 | 0.00 |
| February | 0.110539E+10 | 0.532516E+09 | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.00 | 0.00 |
| March | 0.915518E+09 | 0.468276E+09 | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.00 | 0.00 |
| April | 0.555043E+09 | 0.412512E+09 | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.00 | 0.00 |
| May | 0.548826E+09 | 0.261143E+09 | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.00 | 0.00 |
| June | 0.627090E+09 | 0.129059E+09 | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.00 | 0.00 |
| July | 0.673914E+09 | 0.119835E+09 | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.00 | 0.00 |
| August | 0.856238E+09 | 0.138733E+09 | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.00 | 0.00 |
| September | 0.101137E+10 | 0.211198E+09 | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.00 | 0.00 |
| October | 0.108713E+10 | 0.461882E+09 | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.00 | 0.00 |
| November | 0.124423E+10 | 0.517285E+09 | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.00 | 0.00 |
| December | 0.117428E+10 | 0.635430E+09 | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.110982E+11 | 0.445835E+10 | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.548826E+09 | 0.119835E+09 | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.129915E+10 | 0.635430E+09 | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.151676E+10 | 0.872245E+09 | 0.141093E+10 | 0.111047E+10 | 0.300460E+09 | 0.00 | 0.00 |
| February | 0.134943E+10 | 0.822548E+09 | 0.127205E+10 | 0.960788E+09 | 0.311260E+09 | 0.00 | 0.00 |
| March | 0.126733E+10 | 0.709664E+09 | 0.117448E+10 | 0.729557E+09 | 0.444922E+09 | 0.00 | 0.00 |
| April | 0.867384E+09 | 0.612553E+09 | 0.867391E+09 | 0.367341E+09 | 0.500050E+09 | 0.00 | 0.00 |
| May | 0.103154E+10 | 0.381650E+09 | 0.911587E+09 | 0.240302E+09 | 0.671285E+09 | 0.00 | 0.00 |
| June | 0.129445E+10 | 0.205024E+09 | 0.939478E+09 | 0.324739E+09 | 0.614739E+09 | 0.00 | 0.00 |
| July | 0.123659E+10 | 0.190457E+09 | 0.888237E+09 | 0.237697E+09 | 0.650539E+09 | 0.00 | 0.00 |
| August | 0.143244E+10 | 0.218931E+09 | 0.103528E+10 | 0.466716E+09 | 0.568561E+09 | 0.00 | 0.00 |
| September | 0.148784E+10 | 0.322183E+09 | 0.112860E+10 | 0.604937E+09 | 0.523659E+09 | 0.00 | 0.00 |
| October | 0.143556E+10 | 0.694691E+09 | 0.123337E+10 | 0.827591E+09 | 0.405776E+09 | 0.00 | 0.00 |
| November | 0.147878E+10 | 0.787399E+09 | 0.133436E+10 | 0.101367E+10 | 0.320687E+09 | 0.00 | 0.00 |
| December | 0.133009E+10 | 0.988225E+09 | 0.127656E+10 | 0.984945E+09 | 0.291610E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.157282E+11 | 0.680557E+10 | 0.134723E+11 | 0.786875E+10 | 0.560355E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.867384E+09 | 0.190457E+09 | 0.867391E+09 | 0.237697E+09 | 0.291610E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.151676E+10 | 0.988225E+09 | 0.141093E+10 | 0.111047E+10 | 0.671285E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.245287E+09 | 0.916150E+09 | 0.382899E+09 | 0.166469E+09 | 0.216430E+09 | 0.00 | 0.00 |
| February | 0.275388E+09 | 0.845611E+09 | 0.424545E+09 | 0.179135E+09 | 0.245410E+09 | 0.00 | 0.00 |
| March | 0.458242E+09 | 0.713050E+09 | 0.577395E+09 | 0.205412E+09 | 0.371983E+09 | 0.00 | 0.00 |
| April | 0.461554E+09 | 0.601823E+09 | 0.587068E+09 | 0.143850E+09 | 0.443218E+09 | 0.00 | 0.00 |
| May | 0.805624E+09 | 0.359470E+09 | 0.780044E+09 | 0.162445E+09 | 0.617600E+09 | 0.00 | 0.00 |
| June | 0.116723E+10 | 0.191641E+09 | 0.879796E+09 | 0.284850E+09 | 0.594946E+09 | 0.00 | 0.00 |
| July | 0.106312E+10 | 0.180895E+09 | 0.791785E+09 | 0.179979E+09 | 0.611807E+09 | 0.00 | 0.00 |
| August | 0.962160E+09 | 0.212433E+09 | 0.737531E+09 | 0.228417E+09 | 0.509114E+09 | 0.00 | 0.00 |
| September | 0.757641E+09 | 0.315955E+09 | 0.619363E+09 | 0.184141E+09 | 0.435221E+09 | 0.00 | 0.00 |
| October | 0.458136E+09 | 0.689863E+09 | 0.505693E+09 | 0.188710E+09 | 0.316983E+09 | 0.00 | 0.00 |
| November | 0.279018E+09 | 0.795793E+09 | 0.391563E+09 | 0.159558E+09 | 0.232005E+09 | 0.00 | 0.00 |
| December | 0.183401E+09 | 0.104788E+10 | 0.332117E+09 | 0.129800E+09 | 0.202317E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.711680E+10 | 0.687056E+10 | 0.700980E+10 | 0.221276E+10 | 0.479703E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.183401E+09 | 0.180895E+09 | 0.332117E+09 | 0.129800E+09 | 0.202317E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.116723E+10 | 0.104788E+10 | 0.879796E+09 | 0.284850E+09 | 0.617600E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.148731E+10 | 0.865175E+09 | 0.139543E+10 | 0.109556E+10 | 0.299873E+09 | 0.00 | 0.00 |
| February | 0.135669E+10 | 0.820131E+09 | 0.128111E+10 | 0.969532E+09 | 0.311574E+09 | 0.00 | 0.00 |
| March | 0.129806E+10 | 0.707948E+09 | 0.119936E+10 | 0.755306E+09 | 0.444059E+09 | 0.00 | 0.00 |
| April | 0.927821E+09 | 0.603084E+09 | 0.923850E+09 | 0.417106E+09 | 0.506744E+09 | 0.00 | 0.00 |
| May | 0.107344E+10 | 0.364986E+09 | 0.960167E+09 | 0.288692E+09 | 0.671475E+09 | 0.00 | 0.00 |
| June | 0.134960E+10 | 0.189726E+09 | 0.994631E+09 | 0.375787E+09 | 0.618844E+09 | 0.00 | 0.00 |
| July | 0.136199E+10 | 0.179988E+09 | 0.989727E+09 | 0.332887E+09 | 0.656840E+09 | 0.00 | 0.00 |
| August | 0.154151E+10 | 0.211403E+09 | 0.112114E+10 | 0.538657E+09 | 0.582484E+09 | 0.00 | 0.00 |
| September | 0.153601E+10 | 0.310314E+09 | 0.117455E+10 | 0.653834E+09 | 0.520712E+09 | 0.00 | 0.00 |
| October | 0.141456E+10 | 0.690814E+09 | 0.122395E+10 | 0.815241E+09 | 0.408705E+09 | 0.00 | 0.00 |
| November | 0.144677E+10 | 0.783142E+09 | 0.131294E+10 | 0.990545E+09 | 0.322392E+09 | 0.00 | 0.00 |
| December | 0.132509E+10 | 0.990509E+09 | 0.127324E+10 | 0.980055E+09 | 0.293188E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.161188E+11 | 0.671722E+10 | 0.138501E+11 | 0.821320E+10 | 0.563689E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.927821E+09 | 0.179988E+09 | 0.923850E+09 | 0.288692E+09 | 0.293188E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.154151E+10 | 0.990509E+09 | 0.139543E+10 | 0.109556E+10 | 0.671475E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.206746E+09 | 0.897908E+09 | 0.367398E+09 | 0.151556E+09 | 0.215842E+09 | 0.00 | 0.00 |
| February | 0.279626E+09 | 0.838312E+09 | 0.433603E+09 | 0.187878E+09 | 0.245725E+09 | 0.00 | 0.00 |
| March | 0.477719E+09 | 0.700615E+09 | 0.602280E+09 | 0.231161E+09 | 0.371120E+09 | 0.00 | 0.00 |
| April | 0.521374E+09 | 0.591017E+09 | 0.643528E+09 | 0.193616E+09 | 0.449912E+09 | 0.00 | 0.00 |
| May | 0.856410E+09 | 0.352611E+09 | 0.828624E+09 | 0.210834E+09 | 0.617790E+09 | 0.00 | 0.00 |
| June | 0.123360E+10 | 0.187066E+09 | 0.934949E+09 | 0.335898E+09 | 0.599051E+09 | 0.00 | 0.00 |
| July | 0.119636E+10 | 0.178093E+09 | 0.893276E+09 | 0.275169E+09 | 0.618107E+09 | 0.00 | 0.00 |
| August | 0.107371E+10 | 0.207781E+09 | 0.823395E+09 | 0.300358E+09 | 0.523037E+09 | 0.00 | 0.00 |
| September | 0.802448E+09 | 0.302224E+09 | 0.665313E+09 | 0.233038E+09 | 0.432275E+09 | 0.00 | 0.00 |
| October | 0.431242E+09 | 0.678410E+09 | 0.496272E+09 | 0.176360E+09 | 0.319912E+09 | 0.00 | 0.00 |
| November | 0.246000E+09 | 0.788872E+09 | 0.370145E+09 | 0.136434E+09 | 0.233710E+09 | 0.00 | 0.00 |
| December | 0.168423E+09 | 0.103790E+10 | 0.328804E+09 | 0.124910E+09 | 0.203894E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.749367E+10 | 0.676080E+10 | 0.738759E+10 | 0.255721E+10 | 0.483037E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.168423E+09 | 0.178093E+09 | 0.328804E+09 | 0.124910E+09 | 0.203894E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.123360E+10 | 0.103790E+10 | 0.934949E+09 | 0.335898E+09 | 0.618107E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 24059107.28 | 0.592955E+09 | 0.120064E+09 | 0.00 | 0.120064E+09 | 0.00 | 0.00 |
| February | 27380372.03 | 0.543581E+09 | 0.136302E+09 | 0.00 | 0.136302E+09 | 0.00 | 0.00 |
| March | 96320108.44 | 0.450342E+09 | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.00 | 0.00 |
| April | 0.141527E+09 | 0.373587E+09 | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.00 | 0.00 |
| May | 0.323110E+09 | 0.219969E+09 | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.00 | 0.00 |
| June | 0.493592E+09 | 0.114619E+09 | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.00 | 0.00 |
| July | 0.492926E+09 | 0.109071E+09 | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.00 | 0.00 |
| August | 0.372679E+09 | 0.128722E+09 | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.00 | 0.00 |
| September | 0.269175E+09 | 0.194902E+09 | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.00 | 0.00 |
| October | 0.102883E+09 | 0.429369E+09 | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.00 | 0.00 |
| November | 38069579.28 | 0.506682E+09 | 0.128516E+09 | 0.00 | 0.128516E+09 | 0.00 | 0.00 |
| December | 19686168.12 | 0.675120E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.240141E+10 | 0.433892E+10 | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.00 | 0.00 |
| Minimum of Months | 19686168.12 | 0.109071E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.493592E+09 | 0.675120E+09 | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 23978564.15 | 0.592794E+09 | 0.120064E+09 | 0.00 | 0.120064E+09 | 0.00 | 0.00 |
| February | 27217732.78 | 0.543471E+09 | 0.136302E+09 | 0.00 | 0.136302E+09 | 0.00 | 0.00 |
| March | 95876645.85 | 0.450199E+09 | 0.205412E+09 | 22430.65 | 0.205389E+09 | 0.00 | 0.00 |
| April | 0.141088E+09 | 0.373489E+09 | 0.249673E+09 | 1541450.82 | 0.248132E+09 | 0.00 | 0.00 |
| May | 0.322629E+09 | 0.219880E+09 | 0.352622E+09 | 11831884.31 | 0.340790E+09 | 0.00 | 0.00 |
| June | 0.493420E+09 | 0.114531E+09 | 0.373277E+09 | 40898591.91 | 0.332379E+09 | 0.00 | 0.00 |
| July | 0.492757E+09 | 0.109019E+09 | 0.366063E+09 | 24267214.94 | 0.341796E+09 | 0.00 | 0.00 |
| August | 0.372464E+09 | 0.128654E+09 | 0.291998E+09 | 7981500.09 | 0.284017E+09 | 0.00 | 0.00 |
| September | 0.268858E+09 | 0.194821E+09 | 0.236570E+09 | 155681.14 | 0.236414E+09 | 0.00 | 0.00 |
| October | 0.102519E+09 | 0.429098E+09 | 0.174937E+09 | 0.00 | 0.174937E+09 | 0.00 | 0.00 |
| November | 37908180.84 | 0.506512E+09 | 0.128516E+09 | 0.00 | 0.128516E+09 | 0.00 | 0.00 |
| December | 19632764.37 | 0.674993E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.239835E+10 | 0.433746E+10 | 0.274777E+10 | 86698753.86 | 0.266107E+10 | 0.00 | 0.00 |
| Minimum of Months | 19632764.37 | 0.109019E+09 | 0.112335E+09 | 0.00 | 0.112335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.493420E+09 | 0.674993E+09 | 0.373277E+09 | 40898591.91 | 0.341796E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.130436E+10 | 0.533838E+09 | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.00 | 0.00 |
| February | 0.110625E+10 | 0.505766E+09 | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.00 | 0.00 |
| March | 0.914984E+09 | 0.443070E+09 | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.00 | 0.00 |
| April | 0.555391E+09 | 0.385806E+09 | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.00 | 0.00 |
| May | 0.552028E+09 | 0.241677E+09 | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.00 | 0.00 |
| June | 0.618737E+09 | 0.125329E+09 | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.00 | 0.00 |
| July | 0.665562E+09 | 0.116490E+09 | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.00 | 0.00 |
| August | 0.847478E+09 | 0.134617E+09 | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.00 | 0.00 |
| September | 0.100726E+10 | 0.198953E+09 | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.00 | 0.00 |
| October | 0.109028E+10 | 0.427873E+09 | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.00 | 0.00 |
| November | 0.124569E+10 | 0.483702E+09 | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.00 | 0.00 |
| December | 0.117557E+10 | 0.605664E+09 | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.110836E+11 | 0.420278E+10 | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.552028E+09 | 0.116490E+09 | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.130436E+10 | 0.605664E+09 | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.130417E+10 | 0.533614E+09 | 0.114810E+10 | 0.944002E+09 | 0.204095E+09 | 0.00 | 0.00 |
| February | 0.110601E+10 | 0.505575E+09 | 0.983806E+09 | 0.781654E+09 | 0.202152E+09 | 0.00 | 0.00 |
| March | 0.914656E+09 | 0.442871E+09 | 0.802496E+09 | 0.524168E+09 | 0.278328E+09 | 0.00 | 0.00 |
| April | 0.555012E+09 | 0.385713E+09 | 0.529996E+09 | 0.225032E+09 | 0.304964E+09 | 0.00 | 0.00 |
| May | 0.551637E+09 | 0.241552E+09 | 0.484165E+09 | 89689424.32 | 0.394476E+09 | 0.00 | 0.00 |
| June | 0.618541E+09 | 0.125233E+09 | 0.432959E+09 | 80787839.96 | 0.352171E+09 | 0.00 | 0.00 |
| July | 0.665386E+09 | 0.116434E+09 | 0.462514E+09 | 81985796.69 | 0.380528E+09 | 0.00 | 0.00 |
| August | 0.847290E+09 | 0.134544E+09 | 0.589745E+09 | 0.246281E+09 | 0.343464E+09 | 0.00 | 0.00 |
| September | 0.100706E+10 | 0.198847E+09 | 0.745804E+09 | 0.420952E+09 | 0.324852E+09 | 0.00 | 0.00 |
| October | 0.109008E+10 | 0.427700E+09 | 0.902611E+09 | 0.638881E+09 | 0.263730E+09 | 0.00 | 0.00 |
| November | 0.124553E+10 | 0.483494E+09 | 0.107131E+10 | 0.854111E+09 | 0.217197E+09 | 0.00 | 0.00 |
| December | 0.117542E+10 | 0.605538E+09 | 0.105677E+10 | 0.855145E+09 | 0.201628E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.110808E+11 | 0.420111E+10 | 0.921027E+10 | 0.574269E+10 | 0.346759E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.551637E+09 | 0.116434E+09 | 0.432959E+09 | 80787839.96 | 0.201628E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.130417E+10 | 0.605538E+09 | 0.114810E+10 | 0.944002E+09 | 0.394476E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 52453189.24 | 91314518.91 | 59348719.90 | 36366366.74 | 22982353.17 | 0.00 | 0.00 |
| February | 66946200.82 | 84989683.58 | 71338535.78 | 45082196.02 | 26256339.76 | 0.00 | 0.00 |
| March | 96038791.73 | 71476840.04 | 95230271.16 | 55462573.69 | 39767697.47 | 0.00 | 0.00 |
| April | 93425318.82 | 60922335.28 | 94507050.30 | 46088990.59 | 48418059.71 | 0.00 | 0.00 |
| May | 0.127819E+09 | 38563291.43 | 0.114219E+09 | 47751451.41 | 66467062.71 | 0.00 | 0.00 |
| June | 0.176109E+09 | 21288390.74 | 0.134775E+09 | 70786311.31 | 63989066.19 | 0.00 | 0.00 |
| July | 0.166855E+09 | 20575971.21 | 0.126507E+09 | 60204798.53 | 66302118.88 | 0.00 | 0.00 |
| August | 0.166899E+09 | 23852593.08 | 0.127511E+09 | 70156926.03 | 57353841.99 | 0.00 | 0.00 |
| September | 0.128560E+09 | 33201490.07 | 0.102879E+09 | 55881089.37 | 46997565.57 | 0.00 | 0.00 |
| October | 81075532.24 | 70603105.44 | 77105581.28 | 42318311.41 | 34787269.86 | 0.00 | 0.00 |
| November | 54094903.11 | 81234454.63 | 57979866.92 | 32737958.28 | 25241908.63 | 0.00 | 0.00 |
| December | 43590485.30 | 0.103631E+09 | 51942696.69 | 29972691.87 | 21970004.82 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125387E+10 | 0.701653E+09 | 0.111334E+10 | 0.592810E+09 | 0.520533E+09 | 0.00 | 0.00 |
| Minimum of Months | 43590485.30 | 20575971.21 | 51942696.69 | 29972691.87 | 21970004.82 | 0.00 | 0.00 |
| Maximum of Months | 0.176109E+09 | 0.103631E+09 | 0.134775E+09 | 70786311.31 | 66467062.71 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.163279E+09 | 0.249119E+09 | 0.176755E+09 | 0.108308E+09 | 68447167.19 | 0.00 | 0.00 |
| February | 0.208271E+09 | 0.227979E+09 | 0.212464E+09 | 0.134266E+09 | 78197914.04 | 0.00 | 0.00 |
| March | 0.298016E+09 | 0.194016E+09 | 0.283619E+09 | 0.165181E+09 | 0.118438E+09 | 0.00 | 0.00 |
| April | 0.291638E+09 | 0.163769E+09 | 0.281466E+09 | 0.137264E+09 | 0.144201E+09 | 0.00 | 0.00 |
| May | 0.391820E+09 | 0.106567E+09 | 0.340171E+09 | 0.142216E+09 | 0.197955E+09 | 0.00 | 0.00 |
| June | 0.526050E+09 | 64241391.16 | 0.401395E+09 | 0.210819E+09 | 0.190575E+09 | 0.00 | 0.00 |
| July | 0.497042E+09 | 63264016.89 | 0.376769E+09 | 0.179305E+09 | 0.197464E+09 | 0.00 | 0.00 |
| August | 0.497524E+09 | 73987431.79 | 0.379759E+09 | 0.208945E+09 | 0.170814E+09 | 0.00 | 0.00 |
| September | 0.380547E+09 | 0.104415E+09 | 0.306398E+09 | 0.166428E+09 | 0.139970E+09 | 0.00 | 0.00 |
| October | 0.241476E+09 | 0.210283E+09 | 0.229640E+09 | 0.126034E+09 | 0.103605E+09 | 0.00 | 0.00 |
| November | 0.165777E+09 | 0.229590E+09 | 0.172678E+09 | 97501787.05 | 75176685.69 | 0.00 | 0.00 |
| December | 0.136156E+09 | 0.285267E+09 | 0.154698E+09 | 89266135.50 | 65432141.87 | 0.00 | 0.00 |
| Annual Sum or Average | 0.379760E+10 | 0.197250E+10 | 0.331581E+10 | 0.176553E+10 | 0.155028E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.136156E+09 | 63264016.89 | 0.154698E+09 | 89266135.50 | 65432141.87 | 0.00 | 0.00 |
| Maximum of Months | 0.526050E+09 | 0.285267E+09 | 0.401395E+09 | 0.210819E+09 | 0.197955E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 50316902.32 | 98876913.63 | 59348719.90 | 36366366.74 | 22982353.17 | 0.00 | 0.00 |
| February | 65309989.06 | 91272143.32 | 71338535.78 | 45082196.02 | 26256339.76 | 0.00 | 0.00 |
| March | 94166076.11 | 77329708.90 | 95230271.16 | 55462573.69 | 39767697.47 | 0.00 | 0.00 |
| April | 91803285.01 | 66274481.45 | 94507050.30 | 46088990.59 | 48418059.71 | 0.00 | 0.00 |
| May | 0.124982E+09 | 41444023.58 | 0.114219E+09 | 47751451.41 | 66467062.71 | 0.00 | 0.00 |
| June | 0.176481E+09 | 21870024.63 | 0.134775E+09 | 70786311.31 | 63989066.19 | 0.00 | 0.00 |
| July | 0.167406E+09 | 21135979.84 | 0.126507E+09 | 60204798.53 | 66302118.88 | 0.00 | 0.00 |
| August | 0.167226E+09 | 24657291.86 | 0.127511E+09 | 70156926.03 | 57353841.99 | 0.00 | 0.00 |
| September | 0.127385E+09 | 35456912.44 | 0.102879E+09 | 55881089.37 | 46997565.57 | 0.00 | 0.00 |
| October | 78727028.21 | 77645201.16 | 77105581.28 | 42318311.41 | 34787269.86 | 0.00 | 0.00 |
| November | 52323302.29 | 87928860.82 | 57979866.92 | 32737958.28 | 25241908.63 | 0.00 | 0.00 |
| December | 42038606.11 | 0.111628E+09 | 51942696.69 | 29972691.87 | 21970004.82 | 0.00 | 0.00 |
| Annual Sum or Average | 0.123817E+10 | 0.755519E+09 | 0.111334E+10 | 0.592810E+09 | 0.520533E+09 | 0.00 | 0.00 |
| Minimum of Months | 42038606.11 | 21135979.84 | 51942696.69 | 29972691.87 | 21970004.82 | 0.00 | 0.00 |
| Maximum of Months | 0.176481E+09 | 0.111628E+09 | 0.134775E+09 | 70786311.31 | 66467062.71 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 0.85 | -1.5 | -4.5 | 2.30 | -12.1 | 27.63 | 226.20 | 0.01 |
| February | -0.2 | -2.7 | -6.1 | 3.74 | -13.6 | 32.55 | 253.27 | 0.01 |
| March | 4.82 | 0.36 | -5.5 | 4.48 | -7.8 | 54.65 | 233.06 | 0.03 |
| April | 6.08 | 2.29 | -2.0 | 5.23 | -4.9 | 81.86 | 179.11 | 0.05 |
| May | 13.74 | 7.52 | 1.82 | 4.10 | 2.75 | 117.64 | 180.87 | 0.01 |
| June | 22.16 | 12.46 | 5.10 | 4.19 | 9.76 | 95.26 | 290.95 | 0.00 |
| July | 22.71 | 13.25 | 6.43 | 4.25 | 12.01 | 110.54 | 215.12 | 0.03 |
| August | 21.74 | 12.79 | 6.20 | 3.81 | 10.76 | 77.72 | 272.61 | 0.02 |
| September | 18.54 | 9.35 | 1.35 | 4.13 | 5.52 | 70.51 | 233.03 | 0.01 |
| October | 7.12 | 2.51 | -2.7 | 3.54 | -5.8 | 44.60 | 216.74 | 0.01 |
| November | 3.03 | 0.31 | -2.9 | 2.79 | -8.8 | 30.71 | 220.86 | 0.01 |
| December | -1.0 | -4.5 | -9.5 | 4.43 | -15.4 | 27.45 | 194.75 | 0.01 |
| Annual Sum or Average | 10.02 | 4.37 | -1.0 | 3.91 | -2.2 | 64.46 | 226.11 | 0.02 |
| Minimum of Months | -1.0 | -4.5 | -9.5 | 2.30 | -15.4 | 27.45 | 179.11 | 0.00 |
| Maximum of Months | 22.71 | 13.25 | 6.43 | 5.23 | 12.01 | 117.64 | 290.95 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 21.00 | 20-JAN-12:00 | 6.97 | -11.0 | 0.50 | 6.55 | 41.00 | 961.00 |
| February | 20.00 | 18-FEB-12:00 | 7.74 | -5.0 | 3.60 | 6.35 | 56.00 | 998.00 |
| March | 24.00 | 14-MAR-12:00 | 7.90 | -12.0 | 3.10 | 11.65 | 160.00 | 837.50 |
| April | 22.00 | 19-APR-13:09 | 8.49 | -5.7 | 5.52 | 11.55 | 235.67 | 789.67 |
| May | 29.00 | 17-MAY-12:00 | 11.92 | -3.0 | 5.10 | 18.99 | 432.50 | 162.00 |
| June | 39.40 | 26-JUN-14:00 | 15.63 | -2.8 | 4.60 | 21.96 | 136.50 | 752.00 |
| July | 37.00 | 16-JUL-12:00 | 14.90 | -3.0 | 3.10 | 26.65 | 319.50 | 109.50 |
| August | 37.00 | 16-AUG-13:00 | 16.36 | 3.00 | 3.60 | 28.27 | 90.00 | 895.00 |
| September | 32.70 | 09-SEP-12:00 | 13.05 | -3.9 | 3.00 | 16.30 | 270.50 | 562.00 |
| October | 27.00 | 11-OCT-13:00 | 9.73 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
| November | 22.00 | 06-NOV-13:09 | 7.10 | -13.0 | 2.60 | 4.92 | 88.67 | 883.33 |
| December | 22.00 | 01-DEC-13:00 | 7.94 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 20.00 | 6.97 | -13.0 | 0.50 | 4.92 | 41.00 | 109.50 | |
| Maximum of Months | 39.40 | 16.36 | 3.00 | 5.52 | 28.27 | 432.50 | 998.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -19.0 | 05-JAN-18:00 | -19.0 | -19.0 | 1.50 | -37.1 | 0.00 | 0.00 |
| February | -20.0 | 12-FEB-04:00 | -20.0 | -20.0 | 3.60 | -39.1 | 0.00 | 0.00 |
| March | -15.6 | 19-MAR-06:00 | -15.6 | -15.6 | 10.80 | -25.3 | 24.00 | 0.00 |
| April | -8.0 | 03-APR-02:00 | -8.0 | -8.0 | 3.10 | -22.2 | 0.00 | 0.00 |
| May | -1.0 | 03-MAY-01:00 | -2.4 | -4.0 | 4.10 | -15.7 | 0.00 | 0.00 |
| June | 6.60 | 09-JUN-03:00 | 3.45 | 0.00 | 3.60 | -6.9 | 0.00 | 0.00 |
| July | 9.00 | 02-JUL-04:00 | 3.30 | -3.0 | 3.60 | -5.3 | 20.00 | 184.50 |
| August | 11.00 | 12-AUG-22:00 | 7.22 | 4.00 | 4.10 | 5.13 | 0.00 | 0.00 |
| September | -1.7 | 22-SEP-05:10 | -2.9 | -4.3 | 3.60 | -15.8 | 0.00 | 0.00 |
| October | -10.0 | 30-OCT-03:00 | -10.0 | -10.0 | 2.60 | -18.6 | 0.00 | 0.00 |
| November | -15.0 | 29-NOV-20:00 | -15.0 | -15.0 | 3.10 | -33.5 | 0.00 | 0.00 |
| December | -23.0 | 22-DEC-02:00 | -23.0 | -23.0 | 3.60 | -42.7 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -23.0 | -23.0 | -23.0 | 1.50 | -42.7 | 0.00 | 0.00 | |
| Maximum of Months | 11.00 | 7.22 | 4.00 | 10.80 | 5.13 | 24.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 7.55 | 20-JAN-11:00 | 20.00 | -6.0 | 2.60 | 7.95 | 43.00 | 971.50 |
| February | 7.98 | 18-FEB-14:00 | 19.00 | -3.0 | 3.60 | 5.94 | 151.00 | 410.00 |
| March | 8.00 | 31-MAR-17:00 | 15.00 | 2.00 | 2.60 | 1.58 | 19.50 | 261.00 |
| April | 12.50 | 28-APR-13:00 | 18.00 | 9.00 | 9.80 | 9.72 | 335.00 | 196.50 |
| May | 14.87 | 31-MAY-13:00 | 28.00 | 7.00 | 4.60 | 14.47 | 157.50 | 830.50 |
| June | 19.65 | 18-JUN-11:00 | 29.40 | 15.50 | 6.10 | 16.85 | 272.50 | 596.00 |
| July | 19.75 | 30-JUL-13:00 | 29.00 | 16.00 | 3.60 | 18.99 | 217.50 | 412.00 |
| August | 18.80 | 05-AUG-14:09 | 25.83 | 15.33 | 6.62 | 20.54 | 196.33 | 4.00 |
| September | 14.95 | 01-SEP-11:00 | 24.40 | 9.40 | 3.00 | 10.69 | 193.50 | 684.00 |
| October | 9.73 | 11-OCT-13:00 | 27.00 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
| November | 9.33 | 09-NOV-10:00 | 20.00 | 0.00 | 1.50 | 11.07 | 112.00 | 860.50 |
| December | 7.94 | 01-DEC-13:00 | 22.00 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 7.55 | 15.00 | -9.0 | 1.50 | 1.58 | 19.50 | 4.00 | |
| Maximum of Months | 19.75 | 29.40 | 16.00 | 9.80 | 20.54 | 335.00 | 971.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 5.00 | 28-JAN-10:00 | 5.00 | 5.00 | 1.00 | -6.2 | 207.00 | 309.00 |
| February | 5.00 | 19-FEB-14:30 | 5.00 | 5.00 | 1.80 | -0.4 | 188.00 | 467.00 |
| March | 7.00 | 17-MAR-14:00 | 8.00 | 7.39 | 8.20 | 1.16 | 121.50 | 3.00 |
| April | 9.00 | 28-APR-13:00 | 18.00 | 12.50 | 9.80 | 9.72 | 335.00 | 196.50 |
| May | 11.00 | 21-MAY-21:10 | 12.83 | 11.73 | 2.68 | 6.78 | 0.00 | 0.00 |
| June | 15.50 | 18-JUN-11:00 | 29.40 | 19.65 | 6.10 | 16.85 | 272.50 | 596.00 |
| July | 17.00 | 28-JUL-16:00 | 20.00 | 17.92 | 5.70 | 15.02 | 155.00 | 32.00 |
| August | 18.00 | 04-AUG-01:00 | 18.00 | 18.00 | 2.60 | 8.74 | 0.00 | 0.00 |
| September | 12.20 | 30-SEP-14:00 | 17.20 | 13.90 | 5.10 | 9.72 | 209.00 | 82.50 |
| October | 6.00 | 01-OCT-19:00 | 9.00 | 7.28 | 3.10 | 3.69 | 0.00 | 0.00 |
| November | 7.00 | 09-NOV-23:00 | 8.00 | 7.40 | 4.10 | 3.06 | 0.00 | 0.00 |
| December | 1.00 | 30-DEC-14:00 | 7.00 | 4.06 | 9.80 | -1.2 | 101.00 | 91.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 1.00 | 5.00 | 4.06 | 1.00 | -6.2 | 0.00 | 0.00 | |
| Maximum of Months | 18.00 | 29.40 | 19.65 | 9.80 | 16.85 | 335.00 | 596.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 8.52 | 21.53 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 7.90 | 29.36 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 8.65 | 35.75 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 10.64 | 38.62 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 13.34 | 48.35 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 16.03 | 59.81 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 17.97 | 52.29 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 18.66 | 51.98 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 17.88 | 41.73 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 15.85 | 30.82 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 13.14 | 23.90 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 10.46 | 18.59 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 13.28 | 37.76 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 7.90 | 18.59 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 18.66 | 59.81 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127927E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184465644.4 | 59.44 | 0.00 | 0.00 |
| February | 0.116804E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167025072.6 | 59.44 | 0.00 | 0.00 |
| March | 0.127539E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183319301.9 | 59.44 | 0.00 | 0.00 |
| April | 0.119418E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178699687.6 | 59.44 | 0.00 | 0.00 |
| May | 0.116963E+10 | -991194030.2 | 0.00 | 0.00 | 744.00 | 0.00 | -178438068.6 | 59.44 | 0.00 | 0.00 |
| June | 0.107034E+10 | -903283075.7 | 0.00 | 0.00 | 720.00 | 0.00 | -167052103.5 | 59.44 | 0.00 | 0.00 |
| July | 0.106409E+10 | -891566240.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172519982.2 | 59.44 | 0.00 | 0.00 |
| August | 0.104939E+10 | -876887451.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172499504.0 | 59.44 | 0.00 | 0.00 |
| September | 0.103216E+10 | -864891709.7 | 0.00 | 0.00 | 720.00 | 0.00 | -167267733.9 | 59.44 | 0.00 | 0.00 |
| October | 0.111484E+10 | -937260626.8 | 0.00 | 0.00 | 744.00 | 0.00 | -177582737.4 | 59.44 | 0.00 | 0.00 |
| November | 0.113908E+10 | -963474935.3 | 0.00 | 0.00 | 720.00 | 0.00 | -175600978.9 | 59.44 | 0.00 | 0.00 |
| December | 0.123762E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184548779.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137940E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210902E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103216E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -184548779.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127927E+10 | -864891709.7 | 0.00 | 0.00 | 744.00 | 0.00 | -167025072.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128134E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186535945.7 | 59.44 | 0.00 | 0.00 |
| February | 0.116952E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168507262.6 | 59.44 | 0.00 | 0.00 |
| March | 0.127797E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185898220.2 | 59.44 | 0.00 | 0.00 |
| April | 0.119547E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179995774.3 | 59.44 | 0.00 | 0.00 |
| May | 0.117103E+10 | -991192897.2 | 0.00 | 0.00 | 744.00 | 0.00 | -179839511.3 | 59.44 | 0.00 | 0.00 |
| June | 0.107036E+10 | -903287551.0 | 0.00 | 0.00 | 720.00 | 0.00 | -167070367.6 | 59.44 | 0.00 | 0.00 |
| July | 0.106409E+10 | -891574002.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172520104.5 | 59.44 | 0.00 | 0.00 |
| August | 0.104941E+10 | -876888026.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172522409.0 | 59.44 | 0.00 | 0.00 |
| September | 0.103263E+10 | -864893315.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167737540.4 | 59.44 | 0.00 | 0.00 |
| October | 0.111856E+10 | -937259595.0 | 0.00 | 0.00 | 744.00 | 0.00 | -181302480.5 | 59.44 | 0.00 | 0.00 |
| November | 0.114333E+10 | -963473840.2 | 0.00 | 0.00 | 720.00 | 0.00 | -179855265.7 | 59.44 | 0.00 | 0.00 |
| December | 0.123954E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186471531.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138133E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212826E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103263E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186535945.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128134E+10 | -864893315.8 | 0.00 | 0.00 | 744.00 | 0.00 | -167070367.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128137E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186570176.8 | 59.44 | 0.00 | 0.00 |
| February | 0.116953E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168518248.3 | 59.44 | 0.00 | 0.00 |
| March | 0.127793E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185860393.8 | 59.44 | 0.00 | 0.00 |
| April | 0.119537E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179896778.4 | 59.44 | 0.00 | 0.00 |
| May | 0.117054E+10 | -991195953.8 | 0.00 | 0.00 | 744.00 | 0.00 | -179348714.0 | 59.44 | 0.00 | 0.00 |
| June | 0.107035E+10 | -903282595.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167065255.3 | 59.44 | 0.00 | 0.00 |
| July | 0.106409E+10 | -891566868.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172522384.6 | 59.44 | 0.00 | 0.00 |
| August | 0.104939E+10 | -876887458.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172504674.9 | 59.44 | 0.00 | 0.00 |
| September | 0.103255E+10 | -864891206.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167660164.7 | 59.44 | 0.00 | 0.00 |
| October | 0.111867E+10 | -937259855.6 | 0.00 | 0.00 | 744.00 | 0.00 | -181407751.5 | 59.44 | 0.00 | 0.00 |
| November | 0.114335E+10 | -963473733.8 | 0.00 | 0.00 | 720.00 | 0.00 | -179871376.4 | 59.44 | 0.00 | 0.00 |
| December | 0.123959E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186518224.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138127E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212774E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103255E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186570176.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128137E+10 | -864891206.6 | 0.00 | 0.00 | 744.00 | 0.00 | -167065255.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128135E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186546522.1 | 59.44 | 0.00 | 0.00 |
| February | 0.116953E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168519238.2 | 59.44 | 0.00 | 0.00 |
| March | 0.127799E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185918036.8 | 59.44 | 0.00 | 0.00 |
| April | 0.119551E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180031337.6 | 59.44 | 0.00 | 0.00 |
| May | 0.116960E+10 | -991193235.9 | 0.00 | 0.00 | 744.00 | 0.00 | -178409169.2 | 59.44 | 0.00 | 0.00 |
| June | 0.107028E+10 | -903282806.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166999403.5 | 59.44 | 0.00 | 0.00 |
| July | 0.106407E+10 | -891566341.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172499258.7 | 59.44 | 0.00 | 0.00 |
| August | 0.104938E+10 | -876887522.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172493064.1 | 59.44 | 0.00 | 0.00 |
| September | 0.103236E+10 | -864891762.7 | 0.00 | 0.00 | 720.00 | 0.00 | -167465501.4 | 59.44 | 0.00 | 0.00 |
| October | 0.111784E+10 | -937260479.9 | 0.00 | 0.00 | 744.00 | 0.00 | -180580241.0 | 59.44 | 0.00 | 0.00 |
| November | 0.114331E+10 | -963475078.6 | 0.00 | 0.00 | 720.00 | 0.00 | -179835720.5 | 59.44 | 0.00 | 0.00 |
| December | 0.123956E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186487539.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138108E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212579E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103236E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186546522.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128135E+10 | -864891762.7 | 0.00 | 0.00 | 744.00 | 0.00 | -166999403.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128135E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186547130.6 | 59.44 | 0.00 | 0.00 |
| February | 0.116953E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168518962.3 | 59.44 | 0.00 | 0.00 |
| March | 0.127798E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185908646.1 | 59.44 | 0.00 | 0.00 |
| April | 0.119550E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180020019.0 | 59.44 | 0.00 | 0.00 |
| May | 0.116954E+10 | -991194424.7 | 0.00 | 0.00 | 744.00 | 0.00 | -178341942.8 | 59.44 | 0.00 | 0.00 |
| June | 0.107028E+10 | -903282588.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166998567.4 | 59.44 | 0.00 | 0.00 |
| July | 0.106407E+10 | -891567434.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172498104.3 | 59.44 | 0.00 | 0.00 |
| August | 0.104938E+10 | -876887538.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172492751.6 | 59.44 | 0.00 | 0.00 |
| September | 0.103235E+10 | -864891782.2 | 0.00 | 0.00 | 720.00 | 0.00 | -167459445.8 | 59.44 | 0.00 | 0.00 |
| October | 0.111786E+10 | -937259966.7 | 0.00 | 0.00 | 744.00 | 0.00 | -180600848.1 | 59.44 | 0.00 | 0.00 |
| November | 0.114331E+10 | -963475069.7 | 0.00 | 0.00 | 720.00 | 0.00 | -179834791.1 | 59.44 | 0.00 | 0.00 |
| December | 0.123956E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186489610.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138107E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212571E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103235E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186547130.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128135E+10 | -864891782.2 | 0.00 | 0.00 | 744.00 | 0.00 | -166998567.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127766E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182861075.9 | 59.44 | 0.00 | 0.00 |
| February | 0.116710E+10 | -0.100102E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166088738.5 | 59.44 | 0.00 | 0.00 |
| March | 0.127466E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182588595.5 | 59.44 | 0.00 | 0.00 |
| April | 0.119379E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178314137.6 | 59.44 | 0.00 | 0.00 |
| May | 0.116798E+10 | -991194470.2 | 0.00 | 0.00 | 744.00 | 0.00 | -176788469.9 | 59.44 | 0.00 | 0.00 |
| June | 0.107025E+10 | -903286051.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166966322.7 | 59.44 | 0.00 | 0.00 |
| July | 0.106406E+10 | -891572156.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172492091.0 | 59.44 | 0.00 | 0.00 |
| August | 0.104937E+10 | -876888203.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172486623.8 | 59.44 | 0.00 | 0.00 |
| September | 0.103197E+10 | -864886489.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167088234.2 | 59.44 | 0.00 | 0.00 |
| October | 0.111383E+10 | -937262554.1 | 0.00 | 0.00 | 744.00 | 0.00 | -176565181.3 | 59.44 | 0.00 | 0.00 |
| November | 0.113729E+10 | -963473979.5 | 0.00 | 0.00 | 720.00 | 0.00 | -173814489.3 | 59.44 | 0.00 | 0.00 |
| December | 0.123652E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183449983.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137845E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209950E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103197E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -183449983.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127766E+10 | -864886489.8 | 0.00 | 0.00 | 744.00 | 0.00 | -166088738.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127779E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182983592.8 | 59.44 | 0.00 | 0.00 |
| February | 0.116716E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166148460.3 | 59.44 | 0.00 | 0.00 |
| March | 0.127467E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182594304.7 | 59.44 | 0.00 | 0.00 |
| April | 0.119377E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178289164.2 | 59.44 | 0.00 | 0.00 |
| May | 0.116764E+10 | -991193017.0 | 0.00 | 0.00 | 744.00 | 0.00 | -176444578.9 | 59.44 | 0.00 | 0.00 |
| June | 0.107024E+10 | -903289306.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166947520.5 | 59.44 | 0.00 | 0.00 |
| July | 0.106406E+10 | -891575836.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172485899.6 | 59.44 | 0.00 | 0.00 |
| August | 0.104937E+10 | -876885624.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172485077.6 | 59.44 | 0.00 | 0.00 |
| September | 0.103195E+10 | -864889426.7 | 0.00 | 0.00 | 720.00 | 0.00 | -167060346.5 | 59.44 | 0.00 | 0.00 |
| October | 0.111368E+10 | -937261095.3 | 0.00 | 0.00 | 744.00 | 0.00 | -176423763.1 | 59.44 | 0.00 | 0.00 |
| November | 0.113727E+10 | -963471912.9 | 0.00 | 0.00 | 720.00 | 0.00 | -173801592.4 | 59.44 | 0.00 | 0.00 |
| December | 0.123663E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183558006.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137842E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209922E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103195E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -183558006.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127779E+10 | -864889426.7 | 0.00 | 0.00 | 744.00 | 0.00 | -166148460.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.237068E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181065840.3 | 59.44 | 0.00 | 0.00 |
| February | 0.216631E+10 | -0.200203E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -164274211.8 | 59.44 | 0.00 | 0.00 |
| March | 0.236503E+10 | -0.218415E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180874192.4 | 59.44 | 0.00 | 0.00 |
| April | 0.220616E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175195993.0 | 59.44 | 0.00 | 0.00 |
| May | 0.215680E+10 | -0.198240E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174408746.1 | 59.44 | 0.00 | 0.00 |
| June | 0.197351E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166934180.9 | 59.44 | 0.00 | 0.00 |
| July | 0.195564E+10 | -0.178316E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172489217.3 | 59.44 | 0.00 | 0.00 |
| August | 0.192627E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172493030.8 | 59.44 | 0.00 | 0.00 |
| September | 0.189714E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167358713.3 | 59.44 | 0.00 | 0.00 |
| October | 0.205219E+10 | -0.187452E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177663960.7 | 59.44 | 0.00 | 0.00 |
| November | 0.210127E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174316305.4 | 59.44 | 0.00 | 0.00 |
| December | 0.228935E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183207913.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254603E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209028E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189714E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -183207913.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.237068E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164274211.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.237563E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186019798.0 | 59.44 | 0.00 | 0.00 |
| February | 0.217011E+10 | -0.200204E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168075508.4 | 59.44 | 0.00 | 0.00 |
| March | 0.236753E+10 | -0.218416E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183370271.9 | 59.44 | 0.00 | 0.00 |
| April | 0.220837E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177410255.5 | 59.44 | 0.00 | 0.00 |
| May | 0.215713E+10 | -0.198239E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174737230.8 | 59.44 | 0.00 | 0.00 |
| June | 0.197351E+10 | -0.180657E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166934614.5 | 59.44 | 0.00 | 0.00 |
| July | 0.195564E+10 | -0.178315E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172489646.3 | 59.44 | 0.00 | 0.00 |
| August | 0.192628E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172505147.8 | 59.44 | 0.00 | 0.00 |
| September | 0.189758E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167797330.8 | 59.44 | 0.00 | 0.00 |
| October | 0.205544E+10 | -0.187453E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180918687.5 | 59.44 | 0.00 | 0.00 |
| November | 0.210610E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179147251.6 | 59.44 | 0.00 | 0.00 |
| December | 0.229239E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186245845.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254857E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211565E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189758E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186245845.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.237563E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166934614.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.237061E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180996423.8 | 59.44 | 0.00 | 0.00 |
| February | 0.216616E+10 | -0.200203E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -164127708.7 | 59.44 | 0.00 | 0.00 |
| March | 0.236484E+10 | -0.218415E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180690024.9 | 59.44 | 0.00 | 0.00 |
| April | 0.220584E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174882196.2 | 59.44 | 0.00 | 0.00 |
| May | 0.215668E+10 | -0.198240E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174281163.6 | 59.44 | 0.00 | 0.00 |
| June | 0.197351E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166932390.5 | 59.44 | 0.00 | 0.00 |
| July | 0.195565E+10 | -0.178315E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172493201.0 | 59.44 | 0.00 | 0.00 |
| August | 0.192626E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172488532.4 | 59.44 | 0.00 | 0.00 |
| September | 0.189711E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167329251.3 | 59.44 | 0.00 | 0.00 |
| October | 0.205212E+10 | -0.187452E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177601109.0 | 59.44 | 0.00 | 0.00 |
| November | 0.210131E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174361751.7 | 59.44 | 0.00 | 0.00 |
| December | 0.228930E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183159443.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254594E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208934E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189711E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -183159443.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.237061E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164127708.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.237570E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186093213.3 | 59.44 | 0.00 | 0.00 |
| February | 0.217007E+10 | -0.200204E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168034157.5 | 59.44 | 0.00 | 0.00 |
| March | 0.236739E+10 | -0.218416E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183230279.3 | 59.44 | 0.00 | 0.00 |
| April | 0.220802E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177057325.6 | 59.44 | 0.00 | 0.00 |
| May | 0.215698E+10 | -0.198239E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174586278.2 | 59.44 | 0.00 | 0.00 |
| June | 0.197351E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166933335.0 | 59.44 | 0.00 | 0.00 |
| July | 0.195565E+10 | -0.178316E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490852.2 | 59.44 | 0.00 | 0.00 |
| August | 0.192627E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172496054.1 | 59.44 | 0.00 | 0.00 |
| September | 0.189748E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167702513.1 | 59.44 | 0.00 | 0.00 |
| October | 0.205551E+10 | -0.187452E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180981536.5 | 59.44 | 0.00 | 0.00 |
| November | 0.210613E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179179066.5 | 59.44 | 0.00 | 0.00 |
| December | 0.229246E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186311763.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254852E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211510E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189748E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186311763.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.237570E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166933335.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.237552E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185906678.8 | 59.44 | 0.00 | 0.00 |
| February | 0.217008E+10 | -0.200204E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168043976.3 | 59.44 | 0.00 | 0.00 |
| March | 0.236745E+10 | -0.218416E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183287552.4 | 59.44 | 0.00 | 0.00 |
| April | 0.220796E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177003235.5 | 59.44 | 0.00 | 0.00 |
| May | 0.215658E+10 | -0.198240E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174183856.5 | 59.44 | 0.00 | 0.00 |
| June | 0.197350E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166926921.9 | 59.44 | 0.00 | 0.00 |
| July | 0.195564E+10 | -0.178315E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172489650.6 | 59.44 | 0.00 | 0.00 |
| August | 0.192627E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490124.1 | 59.44 | 0.00 | 0.00 |
| September | 0.189722E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167437154.5 | 59.44 | 0.00 | 0.00 |
| October | 0.205441E+10 | -0.187452E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179883777.6 | 59.44 | 0.00 | 0.00 |
| November | 0.210584E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178882577.0 | 59.44 | 0.00 | 0.00 |
| December | 0.229234E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186196048.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254828E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211273E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189722E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186196048.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.237552E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166926921.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.237552E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185911847.3 | 59.44 | 0.00 | 0.00 |
| February | 0.217007E+10 | -0.200204E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168035785.5 | 59.44 | 0.00 | 0.00 |
| March | 0.236743E+10 | -0.218416E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183269306.1 | 59.44 | 0.00 | 0.00 |
| April | 0.220792E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176957555.9 | 59.44 | 0.00 | 0.00 |
| May | 0.215657E+10 | -0.198240E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174172540.8 | 59.44 | 0.00 | 0.00 |
| June | 0.197350E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166926716.0 | 59.44 | 0.00 | 0.00 |
| July | 0.195564E+10 | -0.178315E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172489619.9 | 59.44 | 0.00 | 0.00 |
| August | 0.192627E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490060.1 | 59.44 | 0.00 | 0.00 |
| September | 0.189721E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167431150.8 | 59.44 | 0.00 | 0.00 |
| October | 0.205443E+10 | -0.187452E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179905354.8 | 59.44 | 0.00 | 0.00 |
| November | 0.210584E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178880783.4 | 59.44 | 0.00 | 0.00 |
| December | 0.229234E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186200249.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254827E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211267E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189721E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186200249.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.237552E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166926716.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.236826E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178646133.6 | 59.44 | 0.00 | 0.00 |
| February | 0.216480E+10 | -0.200204E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -162766900.9 | 59.44 | 0.00 | 0.00 |
| March | 0.236409E+10 | -0.218415E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179936112.3 | 59.44 | 0.00 | 0.00 |
| April | 0.220491E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -173948595.8 | 59.44 | 0.00 | 0.00 |
| May | 0.215620E+10 | -0.198239E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173813974.8 | 59.44 | 0.00 | 0.00 |
| June | 0.197350E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166925066.3 | 59.44 | 0.00 | 0.00 |
| July | 0.195564E+10 | -0.178316E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486374.8 | 59.44 | 0.00 | 0.00 |
| August | 0.192626E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486927.0 | 59.44 | 0.00 | 0.00 |
| September | 0.189690E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167119817.7 | 59.44 | 0.00 | 0.00 |
| October | 0.205095E+10 | -0.187453E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176419595.9 | 59.44 | 0.00 | 0.00 |
| November | 0.209935E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -172405146.5 | 59.44 | 0.00 | 0.00 |
| December | 0.228770E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181553396.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254486E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.207851E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189690E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -181553396.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.236826E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162766900.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.236826E+10 | -0.218961E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178650205.7 | 59.44 | 0.00 | 0.00 |
| February | 0.216480E+10 | -0.200204E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -162764708.3 | 59.44 | 0.00 | 0.00 |
| March | 0.236407E+10 | -0.218415E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179917212.9 | 59.44 | 0.00 | 0.00 |
| April | 0.220488E+10 | -0.203096E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -173920117.4 | 59.44 | 0.00 | 0.00 |
| May | 0.215619E+10 | -0.198239E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173804223.9 | 59.44 | 0.00 | 0.00 |
| June | 0.197350E+10 | -0.180658E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166924945.5 | 59.44 | 0.00 | 0.00 |
| July | 0.195564E+10 | -0.178316E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486361.6 | 59.44 | 0.00 | 0.00 |
| August | 0.192626E+10 | -0.175378E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486919.1 | 59.44 | 0.00 | 0.00 |
| September | 0.189690E+10 | -0.172978E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167118717.6 | 59.44 | 0.00 | 0.00 |
| October | 0.205095E+10 | -0.187453E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176419689.8 | 59.44 | 0.00 | 0.00 |
| November | 0.209937E+10 | -0.192695E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -172419022.5 | 59.44 | 0.00 | 0.00 |
| December | 0.228770E+10 | -0.210614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181554098.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.254485E+11 | -0.233701E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.207847E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.189690E+10 | -0.218961E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -181554098.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.236826E+10 | -0.172978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162764708.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127794E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183139409.2 | 59.44 | 0.00 | 0.00 |
| February | 0.116671E+10 | -0.100102E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165691273.4 | 59.44 | 0.00 | 0.00 |
| March | 0.127452E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182449848.9 | 59.44 | 0.00 | 0.00 |
| April | 0.119230E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176822300.3 | 59.44 | 0.00 | 0.00 |
| May | 0.116903E+10 | -991194155.6 | 0.00 | 0.00 | 744.00 | 0.00 | -177832713.4 | 59.44 | 0.00 | 0.00 |
| June | 0.107077E+10 | -903285655.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167480168.3 | 59.44 | 0.00 | 0.00 |
| July | 0.106451E+10 | -891575234.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172935652.3 | 59.44 | 0.00 | 0.00 |
| August | 0.104992E+10 | -876886349.8 | 0.00 | 0.00 | 744.00 | 0.00 | -173034919.9 | 59.44 | 0.00 | 0.00 |
| September | 0.103404E+10 | -864882990.6 | 0.00 | 0.00 | 720.00 | 0.00 | -169161431.4 | 59.44 | 0.00 | 0.00 |
| October | 0.111822E+10 | -937259940.4 | 0.00 | 0.00 | 744.00 | 0.00 | -180958752.7 | 59.44 | 0.00 | 0.00 |
| November | 0.114001E+10 | -963473678.7 | 0.00 | 0.00 | 720.00 | 0.00 | -176533135.8 | 59.44 | 0.00 | 0.00 |
| December | 0.123732E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184250819.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137953E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211029E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103404E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -184250819.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127794E+10 | -864882990.6 | 0.00 | 0.00 | 744.00 | 0.00 | -165691273.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128088E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186083547.5 | 59.44 | 0.00 | 0.00 |
| February | 0.116907E+10 | -0.100102E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168051563.5 | 59.44 | 0.00 | 0.00 |
| March | 0.127626E+10 | -0.109208E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184181350.5 | 59.44 | 0.00 | 0.00 |
| April | 0.119336E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177884531.0 | 59.44 | 0.00 | 0.00 |
| May | 0.116938E+10 | -991194287.5 | 0.00 | 0.00 | 744.00 | 0.00 | -178185512.3 | 59.44 | 0.00 | 0.00 |
| June | 0.107069E+10 | -903284708.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167410139.7 | 59.44 | 0.00 | 0.00 |
| July | 0.106448E+10 | -891577406.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172899551.8 | 59.44 | 0.00 | 0.00 |
| August | 0.105001E+10 | -876884896.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173121489.3 | 59.44 | 0.00 | 0.00 |
| September | 0.103472E+10 | -864889362.2 | 0.00 | 0.00 | 720.00 | 0.00 | -169832784.3 | 59.44 | 0.00 | 0.00 |
| October | 0.112043E+10 | -937258766.1 | 0.00 | 0.00 | 744.00 | 0.00 | -183174858.8 | 59.44 | 0.00 | 0.00 |
| November | 0.114293E+10 | -963472775.0 | 0.00 | 0.00 | 720.00 | 0.00 | -179458237.6 | 59.44 | 0.00 | 0.00 |
| December | 0.123926E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186194804.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138115E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212648E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103472E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186194804.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128088E+10 | -864889362.2 | 0.00 | 0.00 | 744.00 | 0.00 | -167410139.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127790E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183100994.8 | 59.44 | 0.00 | 0.00 |
| February | 0.116657E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165559836.8 | 59.44 | 0.00 | 0.00 |
| March | 0.127436E+10 | -0.109208E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182285390.9 | 59.44 | 0.00 | 0.00 |
| April | 0.119199E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176509643.2 | 59.44 | 0.00 | 0.00 |
| May | 0.116866E+10 | -991194590.0 | 0.00 | 0.00 | 744.00 | 0.00 | -177462575.3 | 59.44 | 0.00 | 0.00 |
| June | 0.107067E+10 | -903284036.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167382061.2 | 59.44 | 0.00 | 0.00 |
| July | 0.106444E+10 | -891578777.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172859938.6 | 59.44 | 0.00 | 0.00 |
| August | 0.104984E+10 | -876885790.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172949579.2 | 59.44 | 0.00 | 0.00 |
| September | 0.103388E+10 | -864892070.0 | 0.00 | 0.00 | 720.00 | 0.00 | -168986309.0 | 59.44 | 0.00 | 0.00 |
| October | 0.111805E+10 | -937260317.3 | 0.00 | 0.00 | 744.00 | 0.00 | -180786251.4 | 59.44 | 0.00 | 0.00 |
| November | 0.113995E+10 | -963474516.8 | 0.00 | 0.00 | 720.00 | 0.00 | -176470495.5 | 59.44 | 0.00 | 0.00 |
| December | 0.123726E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184190086.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137936E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210854E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103388E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -184190086.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127790E+10 | -864892070.0 | 0.00 | 0.00 | 744.00 | 0.00 | -165559836.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128101E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186210860.8 | 59.44 | 0.00 | 0.00 |
| February | 0.116910E+10 | -0.100102E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168086499.6 | 59.44 | 0.00 | 0.00 |
| March | 0.127604E+10 | -0.109208E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183961311.7 | 59.44 | 0.00 | 0.00 |
| April | 0.119314E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177658093.4 | 59.44 | 0.00 | 0.00 |
| May | 0.116892E+10 | -991194810.5 | 0.00 | 0.00 | 744.00 | 0.00 | -177726685.6 | 59.44 | 0.00 | 0.00 |
| June | 0.107064E+10 | -903286264.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167355519.3 | 59.44 | 0.00 | 0.00 |
| July | 0.106443E+10 | -891579818.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172846549.8 | 59.44 | 0.00 | 0.00 |
| August | 0.104991E+10 | -876884159.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173030183.0 | 59.44 | 0.00 | 0.00 |
| September | 0.103444E+10 | -864887739.2 | 0.00 | 0.00 | 720.00 | 0.00 | -169553166.9 | 59.44 | 0.00 | 0.00 |
| October | 0.112034E+10 | -937261561.5 | 0.00 | 0.00 | 744.00 | 0.00 | -183083290.0 | 59.44 | 0.00 | 0.00 |
| November | 0.114299E+10 | -963474045.5 | 0.00 | 0.00 | 720.00 | 0.00 | -179517443.1 | 59.44 | 0.00 | 0.00 |
| December | 0.123940E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186327863.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138104E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212536E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103444E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186327863.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128101E+10 | -864887739.2 | 0.00 | 0.00 | 744.00 | 0.00 | -167355519.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128104E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186237604.5 | 59.44 | 0.00 | 0.00 |
| February | 0.116921E+10 | -0.100102E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168194419.8 | 59.44 | 0.00 | 0.00 |
| March | 0.127638E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184304163.4 | 59.44 | 0.00 | 0.00 |
| April | 0.119341E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177932600.6 | 59.44 | 0.00 | 0.00 |
| May | 0.116846E+10 | -991193562.0 | 0.00 | 0.00 | 744.00 | 0.00 | -177271334.5 | 59.44 | 0.00 | 0.00 |
| June | 0.107044E+10 | -903287512.2 | 0.00 | 0.00 | 720.00 | 0.00 | -167151224.6 | 59.44 | 0.00 | 0.00 |
| July | 0.106425E+10 | -891571794.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172682842.3 | 59.44 | 0.00 | 0.00 |
| August | 0.104968E+10 | -876886580.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172794650.9 | 59.44 | 0.00 | 0.00 |
| September | 0.103412E+10 | -864887886.0 | 0.00 | 0.00 | 720.00 | 0.00 | -169229009.4 | 59.44 | 0.00 | 0.00 |
| October | 0.112048E+10 | -937261270.8 | 0.00 | 0.00 | 744.00 | 0.00 | -183222849.9 | 59.44 | 0.00 | 0.00 |
| November | 0.114307E+10 | -963475471.7 | 0.00 | 0.00 | 720.00 | 0.00 | -179597303.8 | 59.44 | 0.00 | 0.00 |
| December | 0.123938E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186314527.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138099E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212493E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103412E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186314527.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128104E+10 | -864887886.0 | 0.00 | 0.00 | 744.00 | 0.00 | -167151224.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.128104E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186241680.3 | 59.44 | 0.00 | 0.00 |
| February | 0.116920E+10 | -0.100102E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168188034.7 | 59.44 | 0.00 | 0.00 |
| March | 0.127635E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184273496.5 | 59.44 | 0.00 | 0.00 |
| April | 0.119338E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177901514.2 | 59.44 | 0.00 | 0.00 |
| May | 0.116843E+10 | -991192384.4 | 0.00 | 0.00 | 744.00 | 0.00 | -177239172.8 | 59.44 | 0.00 | 0.00 |
| June | 0.107044E+10 | -903290492.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167147582.5 | 59.44 | 0.00 | 0.00 |
| July | 0.106426E+10 | -891573249.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172683764.3 | 59.44 | 0.00 | 0.00 |
| August | 0.104968E+10 | -876885648.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172791560.3 | 59.44 | 0.00 | 0.00 |
| September | 0.103410E+10 | -864888917.7 | 0.00 | 0.00 | 720.00 | 0.00 | -169214816.5 | 59.44 | 0.00 | 0.00 |
| October | 0.112047E+10 | -937260953.9 | 0.00 | 0.00 | 744.00 | 0.00 | -183213002.7 | 59.44 | 0.00 | 0.00 |
| November | 0.114307E+10 | -963472773.4 | 0.00 | 0.00 | 720.00 | 0.00 | -179595554.5 | 59.44 | 0.00 | 0.00 |
| December | 0.123939E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186322876.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138098E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212481E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103410E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186322876.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.128104E+10 | -864888917.7 | 0.00 | 0.00 | 744.00 | 0.00 | -167147582.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127725E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182450655.4 | 59.44 | 0.00 | 0.00 |
| February | 0.116616E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165145258.3 | 59.44 | 0.00 | 0.00 |
| March | 0.127399E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181916978.3 | 59.44 | 0.00 | 0.00 |
| April | 0.119184E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176360416.6 | 59.44 | 0.00 | 0.00 |
| May | 0.116805E+10 | -991192736.8 | 0.00 | 0.00 | 744.00 | 0.00 | -176860730.7 | 59.44 | 0.00 | 0.00 |
| June | 0.107049E+10 | -903289052.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167204873.9 | 59.44 | 0.00 | 0.00 |
| July | 0.106429E+10 | -891570699.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172715302.6 | 59.44 | 0.00 | 0.00 |
| August | 0.104961E+10 | -876886558.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172725296.2 | 59.44 | 0.00 | 0.00 |
| September | 0.103339E+10 | -864885990.7 | 0.00 | 0.00 | 720.00 | 0.00 | -168499692.5 | 59.44 | 0.00 | 0.00 |
| October | 0.111750E+10 | -937259882.8 | 0.00 | 0.00 | 744.00 | 0.00 | -180241506.6 | 59.44 | 0.00 | 0.00 |
| November | 0.113930E+10 | -963472362.4 | 0.00 | 0.00 | 720.00 | 0.00 | -175826923.1 | 59.44 | 0.00 | 0.00 |
| December | 0.123677E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183701761.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137886E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210365E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103339E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -183701761.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127725E+10 | -864885990.7 | 0.00 | 0.00 | 744.00 | 0.00 | -165145258.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.127726E+10 | -0.109480E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182455017.4 | 59.44 | 0.00 | 0.00 |
| February | 0.116616E+10 | -0.100101E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165142220.4 | 59.44 | 0.00 | 0.00 |
| March | 0.127398E+10 | -0.109207E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181909261.4 | 59.44 | 0.00 | 0.00 |
| April | 0.119182E+10 | -0.101548E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176337445.2 | 59.44 | 0.00 | 0.00 |
| May | 0.116804E+10 | -991192611.8 | 0.00 | 0.00 | 744.00 | 0.00 | -176844079.1 | 59.44 | 0.00 | 0.00 |
| June | 0.107049E+10 | -903289207.0 | 0.00 | 0.00 | 720.00 | 0.00 | -167202900.7 | 59.44 | 0.00 | 0.00 |
| July | 0.106429E+10 | -891571052.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172714543.9 | 59.44 | 0.00 | 0.00 |
| August | 0.104961E+10 | -876886514.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172723543.4 | 59.44 | 0.00 | 0.00 |
| September | 0.103338E+10 | -864886014.2 | 0.00 | 0.00 | 720.00 | 0.00 | -168498655.5 | 59.44 | 0.00 | 0.00 |
| October | 0.111750E+10 | -937259892.8 | 0.00 | 0.00 | 744.00 | 0.00 | -180244341.5 | 59.44 | 0.00 | 0.00 |
| November | 0.113931E+10 | -963472269.0 | 0.00 | 0.00 | 720.00 | 0.00 | -175833365.7 | 59.44 | 0.00 | 0.00 |
| December | 0.123677E+10 | -0.105307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183699430.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137886E+11 | -0.116850E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210360E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.103338E+10 | -0.109480E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -183699430.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.127726E+10 | -864886014.2 | 0.00 | 0.00 | 744.00 | 0.00 | -165142220.4 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 276.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 245.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 296.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 296.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 415.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 421.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 430.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 394.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 354.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 262.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 257.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 251.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 3902.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 245.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 430.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.113661E+10 | 2167.52 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.160863E+10 | 2220.45 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.138948E+10 | 2465.76 | 19-MAR-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.115634E+10 | 1787.31 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.122578E+09 | 1055.64 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.426908E+09 | 1640.75 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.594080E+09 | 1923.71 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.168998E+10 | 2793.40 | 21-DEC-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.812460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.168998E+10 | 2793.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.250777E+10 | 2376.49 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269860E+10 | 2703.95 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.201336E+10 | 2701.96 | 19-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.154344E+10 | 1842.70 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.154830E+09 | 1082.02 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.616160E+09 | 1691.71 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.144266E+10 | 2127.19 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.288738E+10 | 3056.57 | 23-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138642E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.288738E+10 | 3056.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.207762E+09 | 9764.39 | 03-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.521829E+09 | 9764.39 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.260056E+09 | 9764.39 | 02-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.168348E+09 | 9764.39 | 03-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3546560.19 | 9764.39 | 02-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.107453E+09 | 9764.39 | 30-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.136142E+09 | 9764.39 | 01-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.546645E+09 | 9764.39 | 07-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.546645E+09 | 9764.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.252387E+10 | 2375.77 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.270145E+10 | 2759.26 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.196925E+10 | 2689.02 | 19-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.148672E+10 | 1818.09 | 03-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.144825E+09 | 1120.86 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.616064E+09 | 1696.37 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.146475E+10 | 2153.80 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.288960E+10 | 3043.93 | 21-DEC-18:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.137965E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.288960E+10 | 3043.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.177318E+10 | 1740.58 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.194428E+10 | 1992.46 | 12-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.135237E+10 | 1785.51 | 19-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.986784E+09 | 1253.25 | 03-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 84948335.36 | 729.72 | 03-MAY-02:70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.385645E+09 | 1163.14 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.981829E+09 | 1503.24 | 30-NOV-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.204485E+10 | 2267.41 | 23-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.955389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.204485E+10 | 2267.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.177447E+10 | 1740.14 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.194481E+10 | 1995.14 | 12-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.135031E+10 | 1783.81 | 19-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.982977E+09 | 1254.18 | 03-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 84736084.32 | 731.56 | 03-MAY-02:70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.385779E+09 | 1162.92 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.983411E+09 | 1505.15 | 30-NOV-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.204581E+10 | 2266.95 | 23-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.955230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.204581E+10 | 2266.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.542115E+09 | 1480.64 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.942465E+09 | 1508.09 | 12-FEB-04:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.779289E+09 | 1536.43 | 19-MAR-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.620884E+09 | 1175.94 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 65551217.10 | 650.38 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.216539E+09 | 1099.65 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.293054E+09 | 1278.93 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.938724E+09 | 1953.56 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.439862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.942465E+09 | 1953.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.613984E+09 | 1569.98 | 05-JAN-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.104533E+10 | 1634.16 | 07-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.841206E+09 | 1589.86 | 19-MAR-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.660557E+09 | 1280.81 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 68168054.44 | 675.41 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.220609E+09 | 1167.25 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.312080E+09 | 1359.60 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.103146E+10 | 2062.68 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.479340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.104533E+10 | 2062.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.108205E+10 | 3668.11 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.188085E+10 | 4067.68 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.154828E+10 | 4868.70 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.109867E+10 | 3037.01 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 72213357.84 | 1409.29 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.914611E+09 | 3436.67 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107335E+10 | 4135.32 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.288991E+10 | 5657.73 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105599E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.288991E+10 | 5657.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.321959E+10 | 4048.91 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.358341E+10 | 4915.77 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.233771E+10 | 5002.31 | 19-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.146205E+10 | 3108.64 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 98027090.91 | 1487.90 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1666102.72 | 227.23 | 22-SEP-05:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.123491E+10 | 3471.65 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.250491E+10 | 4457.77 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.509375E+10 | 6007.83 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195360E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.509375E+10 | 6007.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.110063E+10 | 3661.28 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.192501E+10 | 4197.43 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.149541E+10 | 4844.59 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107054E+10 | 2960.17 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 67888925.86 | 1314.25 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.908883E+09 | 3453.68 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.109863E+10 | 4198.83 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.288839E+10 | 5715.79 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105554E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.288839E+10 | 5715.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.324919E+10 | 4095.48 | 06-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.359288E+10 | 5047.59 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.226936E+10 | 4975.48 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.141500E+10 | 3031.02 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 92444763.95 | 1612.12 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 217256.48 | 120.29 | 22-SEP-05:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.123157E+10 | 3488.85 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.255092E+10 | 4517.06 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.509658E+10 | 6061.79 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.194982E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.509658E+10 | 6061.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.199663E+10 | 2769.05 | 06-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.232421E+10 | 3407.87 | 12-FEB-04:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.136421E+10 | 3124.90 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.729254E+09 | 1971.36 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22608957.68 | 743.92 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.673677E+09 | 2225.53 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.147300E+10 | 2950.52 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.323642E+10 | 4155.97 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.118200E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.323642E+10 | 4155.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.200011E+10 | 2774.13 | 06-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.232585E+10 | 3415.56 | 12-FEB-04:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.136175E+10 | 3123.20 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.725558E+09 | 1966.20 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22494909.46 | 755.71 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.673215E+09 | 2225.55 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.147769E+10 | 2954.35 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.323878E+10 | 4159.34 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.118255E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.323878E+10 | 4159.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.390430E+09 | 2328.14 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.987150E+09 | 2588.63 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.671022E+09 | 3017.19 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.463366E+09 | 1926.81 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4938742.21 | 341.01 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.436060E+09 | 2172.71 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.458925E+09 | 2609.97 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.140469E+10 | 3777.70 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.481658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.140469E+10 | 3777.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.390957E+09 | 2325.22 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.992217E+09 | 2598.31 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.668565E+09 | 3015.48 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.460908E+09 | 1922.36 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4950039.89 | 328.80 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.434843E+09 | 2172.63 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.460665E+09 | 2613.28 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.140496E+10 | 3781.44 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.481807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.140496E+10 | 3781.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.209008E+10 | 3340.95 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.239397E+10 | 3845.09 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.199297E+10 | 4164.26 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.171806E+10 | 2722.36 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.232725E+09 | 1579.12 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 89091786.10 | 1647.67 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.144576E+10 | 2736.83 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.181727E+10 | 3518.51 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.335260E+10 | 4517.13 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.151325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.335260E+10 | 4517.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.322048E+10 | 3371.34 | 05-JAN-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.328596E+10 | 4020.89 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.240638E+10 | 4199.97 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.190282E+10 | 2718.84 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.251245E+09 | 1599.72 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.120377E+09 | 1708.62 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.175919E+10 | 2751.43 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.263486E+10 | 3579.67 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.446212E+10 | 4590.71 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.200434E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.446212E+10 | 4590.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.209193E+10 | 3353.45 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.239401E+10 | 3894.51 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194897E+10 | 4157.25 | 19-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.167597E+10 | 2704.64 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.218221E+09 | 1605.31 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 84924190.54 | 1631.82 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.144421E+10 | 2747.39 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.182691E+10 | 3535.23 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.334887E+10 | 4531.65 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.150340E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.334887E+10 | 4531.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.323384E+10 | 3383.34 | 05-JAN-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.328275E+10 | 4067.35 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.235564E+10 | 4192.15 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.185610E+10 | 2704.36 | 15-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.239423E+09 | 1698.40 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.111556E+09 | 1682.27 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.174425E+10 | 2762.91 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.265300E+10 | 3595.93 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.445773E+10 | 4602.94 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.199343E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.445773E+10 | 4602.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.241216E+10 | 2573.50 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.245322E+10 | 2990.59 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.169468E+10 | 2959.05 | 19-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.126807E+10 | 1981.42 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.123727E+09 | 1130.76 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 62602021.33 | 1146.38 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.119233E+10 | 2000.37 | 30-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.191352E+10 | 2630.44 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.327324E+10 | 3437.79 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.143935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.327324E+10 | 3437.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.241533E+10 | 2573.83 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.245455E+10 | 2993.69 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.169430E+10 | 2958.89 | 19-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.126737E+10 | 1980.18 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.124026E+09 | 1140.82 | 03-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 62358603.23 | 1142.26 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.119460E+10 | 2001.25 | 30-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.191714E+10 | 2631.04 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.327503E+10 | 3439.29 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.144047E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.327503E+10 | 3439.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.133296E+10 | 2542.47 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.158599E+10 | 2794.80 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.129810E+10 | 2922.68 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.108827E+10 | 1983.87 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.107597E+09 | 1064.77 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 41862376.99 | 1080.76 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.909306E+09 | 1981.75 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.114186E+10 | 2562.34 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.221064E+10 | 3356.11 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.221064E+10 | 3356.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.133632E+10 | 2542.77 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.158916E+10 | 2798.72 | 12-FEB-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.129817E+10 | 2922.54 | 19-MAR-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.108787E+10 | 1982.63 | 17-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.107886E+09 | 1066.47 | 02-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 41854868.79 | 1078.87 | 22-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.910502E+09 | 1982.09 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.114473E+10 | 2564.08 | 30-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.221224E+10 | 3357.67 | 22-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.972873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.221224E+10 | 3357.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 17929408.60 | 17929408.60 | 476.35 | 20-JAN-15:10 | 476.35 | 0.00 |
| February | 0.00 | 0.00 | 2806987.65 | 2806987.65 | 302.74 | 26-FEB-17:08 | 302.74 | 0.00 |
| March | 0.00 | 0.00 | 0.106968E+09 | 0.106968E+09 | 1341.78 | 13-MAR-16:07 | 1341.78 | 0.00 |
| April | 0.00 | 0.00 | 1350547.03 | 1350547.03 | 270.76 | 08-APR-17:17 | 270.76 | 0.00 |
| May | 0.00 | 0.00 | 0.168898E+09 | 0.168576E+09 | 1113.44 | 31-MAY-16:15 | 1113.44 | 0.00 |
| June | 0.00 | 0.00 | 0.220315E+10 | 0.212961E+10 | 2719.29 | 26-JUN-17:20 | 2719.29 | 0.00 |
| July | 0.00 | 0.00 | 0.247658E+10 | 0.235496E+10 | 2432.12 | 15-JUL-17:30 | 2432.12 | 0.00 |
| August | 0.00 | 0.00 | 0.278847E+10 | 0.266941E+10 | 2933.74 | 16-AUG-16:30 | 2933.74 | 0.00 |
| September | 0.00 | 0.00 | 0.243554E+10 | 0.241662E+10 | 2751.26 | 10-SEP-16:05 | 2751.26 | 0.00 |
| October | 0.00 | 0.00 | 0.797272E+09 | 0.797235E+09 | 2566.08 | 11-OCT-15:10 | 2566.08 | 0.00 |
| November | 0.00 | 0.00 | 0.165232E+09 | 0.165232E+09 | 1592.07 | 07-NOV-15:10 | 1592.07 | 0.00 |
| December | 0.00 | 0.00 | 16450927.85 | 16450927.85 | 544.05 | 02-DEC-15:00 | 544.05 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.111806E+11 | 0.108472E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1350547.03 | 1350547.03 | 270.76 | 270.76 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.278847E+10 | 0.266941E+10 | 2933.74 | 2933.74 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 74786014.99 | 74649458.20 | 953.51 | 31-MAY-17:30 | 953.51 | 0.00 |
| June | 0.00 | 0.00 | 0.203673E+10 | 0.196855E+10 | 2675.24 | 26-JUN-17:23 | 2675.24 | 0.00 |
| July | 0.00 | 0.00 | 0.224257E+10 | 0.213343E+10 | 2338.40 | 15-JUL-17:40 | 2338.40 | 0.00 |
| August | 0.00 | 0.00 | 0.215092E+10 | 0.205158E+10 | 2526.42 | 16-AUG-17:00 | 2526.42 | 0.00 |
| September | 0.00 | 0.00 | 0.148582E+10 | 0.147326E+10 | 2119.21 | 10-SEP-16:30 | 2119.21 | 0.00 |
| October | 0.00 | 0.00 | 75557631.10 | 75557631.10 | 1144.28 | 11-OCT-16:10 | 1144.28 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.806638E+10 | 0.777703E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.224257E+10 | 0.213343E+10 | 2675.24 | 2675.24 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.105329E+09 | 0.105329E+09 | 1197.70 | 24-JAN-14:00 | 1197.70 | 0.00 |
| February | 0.00 | 0.00 | 19991017.91 | 19991017.91 | 824.37 | 27-FEB-12:00 | 824.37 | 0.00 |
| March | 0.00 | 0.00 | 0.239475E+09 | 0.239410E+09 | 5120.17 | 15-MAR-08:62 | 5120.17 | 0.00 |
| April | 0.00 | 0.00 | 96619528.79 | 96560502.00 | 984.75 | 20-APR-13:00 | 984.75 | 0.00 |
| May | 0.00 | 0.00 | 0.575709E+09 | 0.567592E+09 | 6458.23 | 17-MAY-08:62 | 6458.23 | 0.00 |
| June | 0.00 | 0.00 | 0.214039E+10 | 0.208411E+10 | 7707.03 | 21-JUN-07:02 | 6039.51 | 0.00 |
| July | 0.00 | 0.00 | 0.215718E+10 | 0.207320E+10 | 7692.47 | 31-JUL-07:02 | 6103.94 | 0.00 |
| August | 0.00 | 0.00 | 0.254287E+10 | 0.246529E+10 | 7907.69 | 04-AUG-07:02 | 5702.24 | 0.00 |
| September | 0.00 | 0.00 | 0.208602E+10 | 0.207391E+10 | 7354.97 | 01-SEP-07:01 | 6897.43 | 0.00 |
| October | 0.00 | 0.00 | 0.792741E+09 | 0.792635E+09 | 6937.49 | 10-OCT-08:62 | 6937.49 | 0.00 |
| November | 0.00 | 0.00 | 0.303226E+09 | 0.303226E+09 | 6112.23 | 07-NOV-09:02 | 6112.23 | 0.00 |
| December | 0.00 | 0.00 | 40900845.92 | 40900845.92 | 1072.74 | 04-DEC-14:00 | 1072.74 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.111005E+11 | 0.108621E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 19991017.91 | 19991017.91 | 824.37 | 824.37 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.254287E+10 | 0.246529E+10 | 7907.69 | 6937.49 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 90604427.26 | 90453886.85 | 814.41 | 17-MAY-13:30 | 814.41 | 0.00 |
| June | 0.00 | 0.00 | 0.212652E+10 | 0.205148E+10 | 2218.62 | 26-JUN-17:27 | 2218.62 | 0.00 |
| July | 0.00 | 0.00 | 0.242130E+10 | 0.230335E+10 | 2145.28 | 16-JUL-15:10 | 2145.28 | 0.00 |
| August | 0.00 | 0.00 | 0.231471E+10 | 0.220242E+10 | 2047.30 | 16-AUG-17:06 | 2047.30 | 0.00 |
| September | 0.00 | 0.00 | 0.155641E+10 | 0.154256E+10 | 1800.21 | 09-SEP-15:10 | 1800.21 | 0.00 |
| October | 0.00 | 0.00 | 70954756.61 | 70954756.61 | 866.46 | 11-OCT-14:10 | 866.46 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.858050E+10 | 0.826121E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.242130E+10 | 0.230335E+10 | 2218.62 | 2218.62 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 67712445.75 | 67546526.13 | 622.58 | 17-MAY-16:05 | 622.58 | 0.00 |
| June | 0.00 | 0.00 | 0.173807E+10 | 0.166921E+10 | 1867.44 | 26-JUN-18:00 | 1867.44 | 0.00 |
| July | 0.00 | 0.00 | 0.203485E+10 | 0.191911E+10 | 1696.60 | 16-JUL-15:10 | 1696.60 | 0.00 |
| August | 0.00 | 0.00 | 0.185593E+10 | 0.175594E+10 | 1683.47 | 16-AUG-17:06 | 1683.47 | 0.00 |
| September | 0.00 | 0.00 | 0.125827E+10 | 0.124573E+10 | 1455.60 | 10-SEP-16:03 | 1455.60 | 0.00 |
| October | 0.00 | 0.00 | 49498973.70 | 49498973.70 | 697.53 | 11-OCT-15:10 | 697.53 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.700432E+10 | 0.670703E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.203485E+10 | 0.191911E+10 | 1867.44 | 1867.44 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 70564174.20 | 70392642.56 | 633.00 | 17-MAY-16:05 | 633.00 | 0.00 |
| June | 0.00 | 0.00 | 0.174361E+10 | 0.167447E+10 | 1858.86 | 26-JUN-18:00 | 1858.86 | 0.00 |
| July | 0.00 | 0.00 | 0.204404E+10 | 0.192781E+10 | 1698.77 | 16-JUL-15:10 | 1698.77 | 0.00 |
| August | 0.00 | 0.00 | 0.186490E+10 | 0.176433E+10 | 1673.09 | 16-AUG-17:06 | 1673.09 | 0.00 |
| September | 0.00 | 0.00 | 0.126329E+10 | 0.125070E+10 | 1451.34 | 10-SEP-16:03 | 1451.34 | 0.00 |
| October | 0.00 | 0.00 | 50043925.55 | 50043041.02 | 695.73 | 11-OCT-15:10 | 695.73 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.703645E+10 | 0.673775E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.204404E+10 | 0.192781E+10 | 1858.86 | 1858.86 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 37914866.68 | 37914866.68 | 564.13 | 20-JAN-14:00 | 564.13 | 0.00 |
| February | 0.00 | 0.00 | 9701793.28 | 9701793.28 | 361.70 | 18-FEB-14:00 | 361.70 | 0.00 |
| March | 0.00 | 0.00 | 0.129208E+09 | 0.129208E+09 | 1203.55 | 14-MAR-13:10 | 1203.55 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.176156E+09 | 0.175622E+09 | 839.57 | 17-MAY-13:30 | 839.57 | 0.00 |
| June | 0.00 | 0.00 | 0.191983E+10 | 0.184428E+10 | 1905.78 | 26-JUN-17:03 | 1905.78 | 0.00 |
| July | 0.00 | 0.00 | 0.228700E+10 | 0.215797E+10 | 1814.26 | 16-JUL-15:10 | 1814.26 | 0.00 |
| August | 0.00 | 0.00 | 0.251908E+10 | 0.239782E+10 | 2135.86 | 16-AUG-14:10 | 2135.86 | 0.00 |
| September | 0.00 | 0.00 | 0.225676E+10 | 0.223743E+10 | 2195.12 | 28-SEP-14:10 | 2195.12 | 0.00 |
| October | 0.00 | 0.00 | 0.844015E+09 | 0.843903E+09 | 2130.47 | 11-OCT-14:10 | 2130.47 | 0.00 |
| November | 0.00 | 0.00 | 0.221588E+09 | 0.221588E+09 | 1432.22 | 07-NOV-14:00 | 1432.22 | 0.00 |
| December | 0.00 | 0.00 | 28592932.00 | 28592932.00 | 494.69 | 17-DEC-14:30 | 494.69 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.104298E+11 | 0.100840E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.251908E+10 | 0.239782E+10 | 2195.12 | 2195.12 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 38967454.89 | 38967454.89 | 561.10 | 25-JAN-14:00 | 561.10 | 0.00 |
| February | 0.00 | 0.00 | 9975550.57 | 9975550.57 | 343.08 | 18-FEB-14:00 | 343.08 | 0.00 |
| March | 0.00 | 0.00 | 0.140631E+09 | 0.140631E+09 | 1258.92 | 14-MAR-13:10 | 1258.92 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.210819E+09 | 0.210117E+09 | 900.16 | 17-MAY-13:40 | 900.16 | 0.00 |
| June | 0.00 | 0.00 | 0.212599E+10 | 0.204201E+10 | 2001.47 | 26-JUN-17:17 | 2001.47 | 0.00 |
| July | 0.00 | 0.00 | 0.255855E+10 | 0.241671E+10 | 1971.08 | 23-JUL-14:00 | 1971.08 | 0.00 |
| August | 0.00 | 0.00 | 0.278676E+10 | 0.265280E+10 | 2215.94 | 16-AUG-14:00 | 2215.94 | 0.00 |
| September | 0.00 | 0.00 | 0.248591E+10 | 0.246469E+10 | 2290.43 | 10-SEP-14:10 | 2290.43 | 0.00 |
| October | 0.00 | 0.00 | 0.926299E+09 | 0.926164E+09 | 2201.16 | 11-OCT-14:10 | 2201.16 | 0.00 |
| November | 0.00 | 0.00 | 0.229405E+09 | 0.229405E+09 | 1446.26 | 07-NOV-14:00 | 1446.26 | 0.00 |
| December | 0.00 | 0.00 | 26575245.70 | 26575245.70 | 485.59 | 17-DEC-14:30 | 485.59 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.115399E+11 | 0.111580E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.278676E+10 | 0.265280E+10 | 2290.43 | 2290.43 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.477083E+09 | 0.477083E+09 | 4036.10 | 20-JAN-15:10 | 4036.10 | 0.00 |
| February | 0.00 | 0.00 | 0.352255E+09 | 0.352255E+09 | 3527.94 | 18-FEB-14:30 | 3527.94 | 0.00 |
| March | 0.00 | 0.00 | 0.111507E+10 | 0.111507E+10 | 5672.95 | 13-MAR-16:07 | 5672.95 | 0.00 |
| April | 0.00 | 0.00 | 0.400077E+09 | 0.400064E+09 | 3433.09 | 08-APR-17:13 | 3433.09 | 0.00 |
| May | 0.00 | 0.00 | 0.218790E+10 | 0.217065E+10 | 4908.42 | 31-MAY-16:25 | 4908.42 | 0.00 |
| June | 0.00 | 0.00 | 0.663232E+10 | 0.639766E+10 | 6966.87 | 26-JUN-17:03 | 6966.87 | 0.00 |
| July | 0.00 | 0.00 | 0.696868E+10 | 0.662138E+10 | 6376.67 | 15-JUL-17:30 | 6376.67 | 0.00 |
| August | 0.00 | 0.00 | 0.695224E+10 | 0.666843E+10 | 7192.11 | 16-AUG-16:30 | 7192.11 | 0.00 |
| September | 0.00 | 0.00 | 0.535407E+10 | 0.531616E+10 | 6668.34 | 28-SEP-15:30 | 6668.34 | 0.00 |
| October | 0.00 | 0.00 | 0.207981E+10 | 0.207976E+10 | 6452.15 | 11-OCT-15:10 | 6452.15 | 0.00 |
| November | 0.00 | 0.00 | 0.817544E+09 | 0.817544E+09 | 5001.01 | 07-NOV-15:00 | 5001.01 | 0.00 |
| December | 0.00 | 0.00 | 0.265542E+09 | 0.265542E+09 | 3204.34 | 02-DEC-15:00 | 3204.34 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.336026E+11 | 0.326816E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.265542E+09 | 0.265542E+09 | 3204.34 | 3204.34 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.696868E+10 | 0.666843E+10 | 7192.11 | 7192.11 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.142501E+09 | 0.142501E+09 | 2308.54 | 13-MAR-16:30 | 2308.54 | 0.00 |
| April | 0.00 | 0.00 | 32386429.39 | 32386429.39 | 1309.27 | 20-APR-17:15 | 1309.27 | 0.00 |
| May | 0.00 | 0.00 | 0.165070E+10 | 0.163594E+10 | 4642.02 | 31-MAY-17:30 | 4642.02 | 0.00 |
| June | 0.00 | 0.00 | 0.627949E+10 | 0.605141E+10 | 6908.73 | 26-JUN-17:27 | 6908.73 | 0.00 |
| July | 0.00 | 0.00 | 0.644713E+10 | 0.611858E+10 | 6182.53 | 15-JUL-17:40 | 6182.53 | 0.00 |
| August | 0.00 | 0.00 | 0.557572E+10 | 0.532361E+10 | 6269.91 | 16-AUG-16:30 | 6269.91 | 0.00 |
| September | 0.00 | 0.00 | 0.333165E+10 | 0.330466E+10 | 5041.54 | 10-SEP-16:30 | 5041.54 | 0.00 |
| October | 0.00 | 0.00 | 0.260453E+09 | 0.260453E+09 | 3195.20 | 11-OCT-15:30 | 3195.20 | 0.00 |
| November | 0.00 | 0.00 | 1475354.91 | 1475354.91 | 325.68 | 07-NOV-15:40 | 325.68 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.237215E+11 | 0.228710E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.644713E+10 | 0.611858E+10 | 6908.73 | 6908.73 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.438315E+09 | 0.438315E+09 | 3721.26 | 20-JAN-14:00 | 3721.26 | 0.00 |
| February | 0.00 | 0.00 | 0.363748E+09 | 0.363748E+09 | 3422.59 | 18-FEB-13:30 | 3422.59 | 0.00 |
| March | 0.00 | 0.00 | 0.112596E+10 | 0.112596E+10 | 5096.21 | 14-MAR-13:00 | 5096.21 | 0.00 |
| April | 0.00 | 0.00 | 0.468956E+09 | 0.468947E+09 | 2869.36 | 21-APR-12:40 | 2869.36 | 0.00 |
| May | 0.00 | 0.00 | 0.233590E+10 | 0.231809E+10 | 4184.17 | 16-MAY-13:30 | 4184.17 | 0.00 |
| June | 0.00 | 0.00 | 0.683763E+10 | 0.658771E+10 | 5730.56 | 30-JUN-14:00 | 5730.56 | 0.00 |
| July | 0.00 | 0.00 | 0.735711E+10 | 0.699589E+10 | 5747.87 | 18-JUL-13:00 | 5747.87 | 0.00 |
| August | 0.00 | 0.00 | 0.730706E+10 | 0.699802E+10 | 6293.75 | 16-AUG-13:20 | 6293.75 | 0.00 |
| September | 0.00 | 0.00 | 0.552478E+10 | 0.548424E+10 | 6118.10 | 28-SEP-13:40 | 6118.10 | 0.00 |
| October | 0.00 | 0.00 | 0.201451E+10 | 0.201443E+10 | 5693.95 | 11-OCT-13:50 | 5693.95 | 0.00 |
| November | 0.00 | 0.00 | 0.791972E+09 | 0.791972E+09 | 4403.72 | 07-NOV-14:00 | 4403.72 | 0.00 |
| December | 0.00 | 0.00 | 0.231722E+09 | 0.231722E+09 | 2465.26 | 02-DEC-14:30 | 2465.26 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.347977E+11 | 0.338190E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.231722E+09 | 0.231722E+09 | 2465.26 | 2465.26 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.735711E+10 | 0.699802E+10 | 6293.75 | 6293.75 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.145067E+09 | 0.145067E+09 | 1662.84 | 14-MAR-16:07 | 1662.84 | 0.00 |
| April | 0.00 | 0.00 | 62345955.45 | 62345955.45 | 1179.34 | 20-APR-13:00 | 1179.34 | 0.00 |
| May | 0.00 | 0.00 | 0.178500E+10 | 0.176968E+10 | 3540.68 | 17-MAY-13:30 | 3540.68 | 0.00 |
| June | 0.00 | 0.00 | 0.648568E+10 | 0.624261E+10 | 5453.60 | 26-JUN-17:30 | 5453.60 | 0.00 |
| July | 0.00 | 0.00 | 0.683648E+10 | 0.649315E+10 | 5373.63 | 16-JUL-14:30 | 5373.63 | 0.00 |
| August | 0.00 | 0.00 | 0.592959E+10 | 0.564991E+10 | 4826.23 | 16-AUG-16:30 | 4826.23 | 0.00 |
| September | 0.00 | 0.00 | 0.347695E+10 | 0.344689E+10 | 4027.74 | 09-SEP-15:00 | 4027.74 | 0.00 |
| October | 0.00 | 0.00 | 0.232939E+09 | 0.232939E+09 | 2274.75 | 11-OCT-14:10 | 2274.75 | 0.00 |
| November | 0.00 | 0.00 | 539895.96 | 539895.96 | 110.04 | 09-NOV-14:00 | 110.04 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.249546E+11 | 0.240431E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.683648E+10 | 0.649315E+10 | 5453.60 | 5453.60 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 85617171.77 | 85617171.77 | 1180.29 | 14-MAR-16:07 | 1180.29 | 0.00 |
| April | 0.00 | 0.00 | 10432162.01 | 10432162.01 | 538.00 | 20-APR-20:00 | 538.00 | 0.00 |
| May | 0.00 | 0.00 | 0.142446E+10 | 0.140639E+10 | 2786.46 | 31-MAY-18:00 | 2784.09 | 0.00 |
| June | 0.00 | 0.00 | 0.495180E+10 | 0.474348E+10 | 4427.88 | 26-JUN-18:00 | 4427.88 | 0.00 |
| July | 0.00 | 0.00 | 0.533531E+10 | 0.502869E+10 | 4018.38 | 16-JUL-15:10 | 4018.38 | 0.00 |
| August | 0.00 | 0.00 | 0.453404E+10 | 0.429421E+10 | 3804.57 | 16-AUG-17:04 | 3804.57 | 0.00 |
| September | 0.00 | 0.00 | 0.276194E+10 | 0.273469E+10 | 3082.86 | 10-SEP-16:05 | 3082.86 | 0.00 |
| October | 0.00 | 0.00 | 0.171638E+09 | 0.171638E+09 | 1854.38 | 11-OCT-15:10 | 1854.38 | 0.00 |
| November | 0.00 | 0.00 | 501537.86 | 501537.86 | 106.83 | 09-NOV-14:00 | 106.83 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.192757E+11 | 0.184757E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.533531E+10 | 0.502869E+10 | 4427.88 | 4427.88 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 88491627.33 | 88491627.33 | 1200.53 | 14-MAR-16:07 | 1200.53 | 0.00 |
| April | 0.00 | 0.00 | 12740481.97 | 12740481.97 | 535.22 | 20-APR-20:00 | 535.22 | 0.00 |
| May | 0.00 | 0.00 | 0.143731E+10 | 0.141922E+10 | 2761.78 | 31-MAY-18:00 | 2759.42 | 0.00 |
| June | 0.00 | 0.00 | 0.496067E+10 | 0.475194E+10 | 4404.11 | 26-JUN-18:00 | 4404.11 | 0.00 |
| July | 0.00 | 0.00 | 0.535040E+10 | 0.504321E+10 | 4024.02 | 16-JUL-15:10 | 4024.02 | 0.00 |
| August | 0.00 | 0.00 | 0.454924E+10 | 0.430856E+10 | 3780.35 | 16-AUG-17:04 | 3780.35 | 0.00 |
| September | 0.00 | 0.00 | 0.277182E+10 | 0.274451E+10 | 3066.05 | 10-SEP-16:05 | 3066.05 | 0.00 |
| October | 0.00 | 0.00 | 0.173126E+09 | 0.173125E+09 | 1849.64 | 11-OCT-15:10 | 1849.64 | 0.00 |
| November | 0.00 | 0.00 | 541173.81 | 541173.81 | 110.06 | 09-NOV-14:00 | 110.06 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.193443E+11 | 0.185423E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.535040E+10 | 0.504321E+10 | 4404.11 | 4404.11 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.724715E+09 | 0.724715E+09 | 3923.47 | 20-JAN-14:00 | 3923.47 | 0.00 |
| February | 0.00 | 0.00 | 0.512622E+09 | 0.512622E+09 | 3423.16 | 18-FEB-13:30 | 3423.16 | 0.00 |
| March | 0.00 | 0.00 | 0.105668E+10 | 0.105668E+10 | 4479.85 | 14-MAR-13:00 | 4479.85 | 0.00 |
| April | 0.00 | 0.00 | 0.350894E+09 | 0.350829E+09 | 2265.00 | 21-APR-13:25 | 2265.00 | 0.00 |
| May | 0.00 | 0.00 | 0.198407E+10 | 0.196300E+10 | 3244.20 | 16-MAY-13:30 | 3244.20 | 0.00 |
| June | 0.00 | 0.00 | 0.530634E+10 | 0.508993E+10 | 4469.91 | 26-JUN-15:10 | 4469.91 | 0.00 |
| July | 0.00 | 0.00 | 0.586044E+10 | 0.553340E+10 | 4417.03 | 23-JUL-13:50 | 4417.03 | 0.00 |
| August | 0.00 | 0.00 | 0.592038E+10 | 0.564690E+10 | 5013.76 | 16-AUG-14:00 | 5013.76 | 0.00 |
| September | 0.00 | 0.00 | 0.484869E+10 | 0.480982E+10 | 5255.53 | 28-SEP-14:00 | 5255.53 | 0.00 |
| October | 0.00 | 0.00 | 0.214052E+10 | 0.214033E+10 | 5155.59 | 11-OCT-14:10 | 5155.59 | 0.00 |
| November | 0.00 | 0.00 | 0.104444E+10 | 0.104444E+10 | 4369.50 | 07-NOV-14:00 | 4369.50 | 0.00 |
| December | 0.00 | 0.00 | 0.409922E+09 | 0.409922E+09 | 2769.63 | 02-DEC-14:30 | 2769.63 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.301597E+11 | 0.292826E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.350894E+09 | 0.350829E+09 | 2265.00 | 2265.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.592038E+10 | 0.564690E+10 | 5255.53 | 5255.53 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.728327E+09 | 0.728327E+09 | 3930.50 | 20-JAN-14:00 | 3930.50 | 0.00 |
| February | 0.00 | 0.00 | 0.520445E+09 | 0.520445E+09 | 3442.61 | 18-FEB-13:30 | 3442.61 | 0.00 |
| March | 0.00 | 0.00 | 0.106073E+10 | 0.106073E+10 | 4497.11 | 14-MAR-13:00 | 4497.11 | 0.00 |
| April | 0.00 | 0.00 | 0.359624E+09 | 0.359554E+09 | 2297.93 | 21-APR-13:25 | 2297.93 | 0.00 |
| May | 0.00 | 0.00 | 0.199677E+10 | 0.197570E+10 | 3263.14 | 16-MAY-13:30 | 3263.14 | 0.00 |
| June | 0.00 | 0.00 | 0.531544E+10 | 0.509862E+10 | 4467.42 | 26-JUN-15:10 | 4467.42 | 0.00 |
| July | 0.00 | 0.00 | 0.587549E+10 | 0.554794E+10 | 4432.33 | 23-JUL-13:50 | 4432.33 | 0.00 |
| August | 0.00 | 0.00 | 0.593490E+10 | 0.566069E+10 | 5019.09 | 16-AUG-14:00 | 5019.09 | 0.00 |
| September | 0.00 | 0.00 | 0.485680E+10 | 0.481789E+10 | 5267.34 | 28-SEP-13:50 | 5267.34 | 0.00 |
| October | 0.00 | 0.00 | 0.214118E+10 | 0.214099E+10 | 5156.46 | 11-OCT-14:10 | 5156.46 | 0.00 |
| November | 0.00 | 0.00 | 0.104636E+10 | 0.104636E+10 | 4373.74 | 07-NOV-14:00 | 4373.74 | 0.00 |
| December | 0.00 | 0.00 | 0.411510E+09 | 0.411510E+09 | 2764.36 | 02-DEC-14:30 | 2764.36 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.302476E+11 | 0.293687E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.359624E+09 | 0.359554E+09 | 2297.93 | 2297.93 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.593490E+10 | 0.566069E+10 | 5267.34 | 5267.34 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.328123E+09 | 0.328123E+09 | 2875.26 | 20-JAN-15:10 | 2875.26 | 0.00 |
| February | 0.00 | 0.00 | 0.304030E+09 | 0.304030E+09 | 2596.89 | 18-FEB-14:30 | 2596.89 | 0.00 |
| March | 0.00 | 0.00 | 0.666092E+09 | 0.666092E+09 | 3489.67 | 13-MAR-15:30 | 3489.67 | 0.00 |
| April | 0.00 | 0.00 | 0.380593E+09 | 0.380577E+09 | 2410.19 | 07-APR-15:30 | 2410.19 | 0.00 |
| May | 0.00 | 0.00 | 0.108845E+10 | 0.108478E+10 | 3365.36 | 31-MAY-16:07 | 3365.36 | 0.00 |
| June | 0.00 | 0.00 | 0.360129E+10 | 0.350330E+10 | 4725.97 | 26-JUN-17:03 | 4725.97 | 0.00 |
| July | 0.00 | 0.00 | 0.372885E+10 | 0.357984E+10 | 4380.78 | 15-JUL-15:30 | 4380.78 | 0.00 |
| August | 0.00 | 0.00 | 0.366475E+10 | 0.356010E+10 | 4949.37 | 16-AUG-16:04 | 4949.37 | 0.00 |
| September | 0.00 | 0.00 | 0.265101E+10 | 0.263922E+10 | 4330.23 | 10-SEP-15:20 | 4330.23 | 0.00 |
| October | 0.00 | 0.00 | 0.103842E+10 | 0.103842E+10 | 4019.03 | 11-OCT-15:10 | 4019.03 | 0.00 |
| November | 0.00 | 0.00 | 0.518086E+09 | 0.518086E+09 | 3167.58 | 05-NOV-15:10 | 3167.58 | 0.00 |
| December | 0.00 | 0.00 | 0.251775E+09 | 0.251775E+09 | 2492.36 | 01-DEC-14:50 | 2492.36 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.182215E+11 | 0.178543E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.251775E+09 | 0.251775E+09 | 2410.19 | 2410.19 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.372885E+10 | 0.357984E+10 | 4949.37 | 4949.37 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 1067560.36 | 1067560.36 | 209.03 | 20-JAN-16:30 | 209.03 | 0.00 |
| February | 0.00 | 0.00 | 795429.87 | 795429.87 | 132.85 | 18-FEB-17:35 | 132.85 | 0.00 |
| March | 0.00 | 0.00 | 0.114577E+09 | 0.114577E+09 | 1721.42 | 13-MAR-16:30 | 1721.42 | 0.00 |
| April | 0.00 | 0.00 | 0.101842E+09 | 0.101842E+09 | 1341.30 | 20-APR-17:20 | 1341.30 | 0.00 |
| May | 0.00 | 0.00 | 0.815275E+09 | 0.812143E+09 | 3112.59 | 31-MAY-17:05 | 3112.59 | 0.00 |
| June | 0.00 | 0.00 | 0.339727E+10 | 0.330140E+10 | 4672.91 | 26-JUN-17:15 | 4672.91 | 0.00 |
| July | 0.00 | 0.00 | 0.343995E+10 | 0.329859E+10 | 4082.45 | 15-JUL-17:30 | 4082.45 | 0.00 |
| August | 0.00 | 0.00 | 0.293674E+10 | 0.284361E+10 | 4391.67 | 16-AUG-16:30 | 4391.67 | 0.00 |
| September | 0.00 | 0.00 | 0.165677E+10 | 0.164853E+10 | 3369.06 | 10-SEP-16:30 | 3369.06 | 0.00 |
| October | 0.00 | 0.00 | 0.162404E+09 | 0.162404E+09 | 2012.14 | 11-OCT-15:30 | 2012.14 | 0.00 |
| November | 0.00 | 0.00 | 17201250.45 | 17201250.45 | 689.80 | 07-NOV-15:30 | 689.80 | 0.00 |
| December | 0.00 | 0.00 | 657353.21 | 657353.21 | 158.60 | 02-DEC-15:00 | 158.60 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.126445E+11 | 0.123028E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 657353.21 | 657353.21 | 132.85 | 132.85 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.343995E+10 | 0.330140E+10 | 4672.91 | 4672.91 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.293110E+09 | 0.293110E+09 | 2673.71 | 20-JAN-14:00 | 2673.71 | 0.00 |
| February | 0.00 | 0.00 | 0.286666E+09 | 0.286666E+09 | 2444.47 | 18-FEB-13:40 | 2444.47 | 0.00 |
| March | 0.00 | 0.00 | 0.646339E+09 | 0.646339E+09 | 3127.39 | 14-MAR-13:00 | 3127.39 | 0.00 |
| April | 0.00 | 0.00 | 0.381122E+09 | 0.381118E+09 | 2207.20 | 19-APR-13:30 | 2207.20 | 0.00 |
| May | 0.00 | 0.00 | 0.110536E+10 | 0.110191E+10 | 2847.51 | 16-MAY-13:30 | 2847.51 | 0.00 |
| June | 0.00 | 0.00 | 0.368857E+10 | 0.358165E+10 | 3981.60 | 30-JUN-14:00 | 3981.60 | 0.00 |
| July | 0.00 | 0.00 | 0.391810E+10 | 0.376269E+10 | 3974.52 | 23-JUL-13:30 | 3974.52 | 0.00 |
| August | 0.00 | 0.00 | 0.383504E+10 | 0.371699E+10 | 4460.38 | 16-AUG-13:20 | 4460.38 | 0.00 |
| September | 0.00 | 0.00 | 0.271087E+10 | 0.269756E+10 | 4101.95 | 09-SEP-12:50 | 4101.95 | 0.00 |
| October | 0.00 | 0.00 | 0.984505E+09 | 0.984505E+09 | 3526.09 | 11-OCT-14:00 | 3526.09 | 0.00 |
| November | 0.00 | 0.00 | 0.484778E+09 | 0.484778E+09 | 2806.86 | 05-NOV-13:30 | 2806.86 | 0.00 |
| December | 0.00 | 0.00 | 0.224571E+09 | 0.224571E+09 | 2099.19 | 01-DEC-14:00 | 2099.19 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.185590E+11 | 0.181619E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.224571E+09 | 0.224571E+09 | 2099.19 | 2099.19 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.391810E+10 | 0.376269E+10 | 4460.38 | 4460.38 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 92659.89 | 92659.89 | 34.32 | 18-FEB-14:30 | 34.32 | 0.00 |
| March | 0.00 | 0.00 | 77831833.78 | 77831833.78 | 1073.46 | 14-MAR-13:40 | 1073.46 | 0.00 |
| April | 0.00 | 0.00 | 0.102730E+09 | 0.102730E+09 | 1223.73 | 20-APR-13:00 | 1223.73 | 0.00 |
| May | 0.00 | 0.00 | 0.821897E+09 | 0.819060E+09 | 2266.80 | 17-MAY-13:40 | 2266.80 | 0.00 |
| June | 0.00 | 0.00 | 0.349395E+10 | 0.338851E+10 | 3616.09 | 26-JUN-17:03 | 3616.09 | 0.00 |
| July | 0.00 | 0.00 | 0.363393E+10 | 0.348557E+10 | 3584.54 | 16-JUL-14:40 | 3584.54 | 0.00 |
| August | 0.00 | 0.00 | 0.310540E+10 | 0.299761E+10 | 3372.96 | 16-AUG-14:00 | 3372.96 | 0.00 |
| September | 0.00 | 0.00 | 0.168759E+10 | 0.167778E+10 | 2763.39 | 09-SEP-13:30 | 2763.39 | 0.00 |
| October | 0.00 | 0.00 | 0.106305E+09 | 0.106305E+09 | 1383.75 | 11-OCT-14:10 | 1383.75 | 0.00 |
| November | 0.00 | 0.00 | 8229329.41 | 8229329.41 | 302.97 | 06-NOV-14:00 | 302.97 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.130380E+11 | 0.126637E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.363393E+10 | 0.348557E+10 | 3616.09 | 3616.09 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 35567215.83 | 35567215.83 | 685.21 | 14-MAR-16:07 | 685.21 | 0.00 |
| April | 0.00 | 0.00 | 40583745.06 | 40583745.06 | 690.96 | 20-APR-13:20 | 690.96 | 0.00 |
| May | 0.00 | 0.00 | 0.576150E+09 | 0.573497E+09 | 1835.10 | 31-MAY-16:07 | 1835.10 | 0.00 |
| June | 0.00 | 0.00 | 0.269925E+10 | 0.260911E+10 | 3024.65 | 26-JUN-17:23 | 3024.65 | 0.00 |
| July | 0.00 | 0.00 | 0.286529E+10 | 0.272940E+10 | 2768.03 | 16-JUL-15:10 | 2768.03 | 0.00 |
| August | 0.00 | 0.00 | 0.237944E+10 | 0.228764E+10 | 2773.21 | 16-AUG-16:17 | 2773.21 | 0.00 |
| September | 0.00 | 0.00 | 0.128968E+10 | 0.128162E+10 | 2105.16 | 09-SEP-14:10 | 2105.16 | 0.00 |
| October | 0.00 | 0.00 | 60574538.35 | 60574538.35 | 1082.08 | 11-OCT-15:10 | 1082.08 | 0.00 |
| November | 0.00 | 0.00 | 1020203.24 | 1020203.24 | 94.73 | 07-NOV-15:10 | 94.73 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.994756E+10 | 0.961902E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.286529E+10 | 0.272940E+10 | 3024.65 | 3024.65 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 36794472.75 | 36794472.75 | 696.66 | 14-MAR-16:07 | 696.66 | 0.00 |
| April | 0.00 | 0.00 | 43145800.88 | 43145800.88 | 726.03 | 20-APR-13:20 | 726.03 | 0.00 |
| May | 0.00 | 0.00 | 0.584377E+09 | 0.581702E+09 | 1818.26 | 31-MAY-16:07 | 1818.26 | 0.00 |
| June | 0.00 | 0.00 | 0.270629E+10 | 0.261581E+10 | 2998.55 | 26-JUN-17:15 | 2998.55 | 0.00 |
| July | 0.00 | 0.00 | 0.287563E+10 | 0.273944E+10 | 2770.91 | 16-JUL-15:10 | 2770.91 | 0.00 |
| August | 0.00 | 0.00 | 0.238982E+10 | 0.229751E+10 | 2752.71 | 16-AUG-16:17 | 2752.71 | 0.00 |
| September | 0.00 | 0.00 | 0.129707E+10 | 0.128896E+10 | 2113.88 | 09-SEP-13:30 | 2113.88 | 0.00 |
| October | 0.00 | 0.00 | 61512407.36 | 61512407.36 | 1077.53 | 11-OCT-15:10 | 1077.53 | 0.00 |
| November | 0.00 | 0.00 | 1275830.97 | 1275830.97 | 103.53 | 07-NOV-15:10 | 103.53 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.999592E+10 | 0.966615E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.287563E+10 | 0.273944E+10 | 2998.55 | 2998.55 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.333782E+09 | 0.333782E+09 | 2555.50 | 20-JAN-14:00 | 2555.50 | 0.00 |
| February | 0.00 | 0.00 | 0.287800E+09 | 0.287800E+09 | 2241.42 | 18-FEB-14:00 | 2241.42 | 0.00 |
| March | 0.00 | 0.00 | 0.548414E+09 | 0.548414E+09 | 2712.51 | 15-MAR-13:50 | 2712.51 | 0.00 |
| April | 0.00 | 0.00 | 0.275394E+09 | 0.275379E+09 | 1681.65 | 20-APR-13:00 | 1681.65 | 0.00 |
| May | 0.00 | 0.00 | 0.849694E+09 | 0.846271E+09 | 2258.49 | 16-MAY-13:50 | 2258.49 | 0.00 |
| June | 0.00 | 0.00 | 0.289988E+10 | 0.280742E+10 | 3258.32 | 26-JUN-15:10 | 3258.32 | 0.00 |
| July | 0.00 | 0.00 | 0.315533E+10 | 0.301107E+10 | 3242.98 | 23-JUL-13:40 | 3242.98 | 0.00 |
| August | 0.00 | 0.00 | 0.311801E+10 | 0.301356E+10 | 3691.38 | 16-AUG-14:00 | 3691.38 | 0.00 |
| September | 0.00 | 0.00 | 0.230946E+10 | 0.229718E+10 | 3516.99 | 28-SEP-13:40 | 3516.99 | 0.00 |
| October | 0.00 | 0.00 | 0.907903E+09 | 0.907903E+09 | 3239.84 | 11-OCT-14:10 | 3239.84 | 0.00 |
| November | 0.00 | 0.00 | 0.497693E+09 | 0.497693E+09 | 2626.55 | 05-NOV-13:50 | 2626.55 | 0.00 |
| December | 0.00 | 0.00 | 0.258349E+09 | 0.258349E+09 | 2023.53 | 01-DEC-14:00 | 2023.53 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.154417E+11 | 0.150848E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.258349E+09 | 0.258349E+09 | 1681.65 | 1681.65 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.315533E+10 | 0.301356E+10 | 3691.38 | 3691.38 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.337744E+09 | 0.337744E+09 | 2565.80 | 20-JAN-14:00 | 2565.80 | 0.00 |
| February | 0.00 | 0.00 | 0.293345E+09 | 0.293345E+09 | 2257.02 | 18-FEB-13:40 | 2257.02 | 0.00 |
| March | 0.00 | 0.00 | 0.553458E+09 | 0.553458E+09 | 2728.45 | 15-MAR-13:50 | 2728.45 | 0.00 |
| April | 0.00 | 0.00 | 0.281505E+09 | 0.281489E+09 | 1712.51 | 20-APR-13:00 | 1712.51 | 0.00 |
| May | 0.00 | 0.00 | 0.858774E+09 | 0.855336E+09 | 2274.60 | 16-MAY-13:50 | 2274.60 | 0.00 |
| June | 0.00 | 0.00 | 0.290746E+10 | 0.281467E+10 | 3252.15 | 26-JUN-15:10 | 3252.15 | 0.00 |
| July | 0.00 | 0.00 | 0.316581E+10 | 0.302129E+10 | 3253.82 | 23-JUL-13:40 | 3253.82 | 0.00 |
| August | 0.00 | 0.00 | 0.312806E+10 | 0.302318E+10 | 3697.35 | 16-AUG-14:00 | 3697.35 | 0.00 |
| September | 0.00 | 0.00 | 0.231690E+10 | 0.230457E+10 | 3530.51 | 28-SEP-13:40 | 3530.51 | 0.00 |
| October | 0.00 | 0.00 | 0.912368E+09 | 0.912368E+09 | 3240.77 | 11-OCT-14:10 | 3240.77 | 0.00 |
| November | 0.00 | 0.00 | 0.501643E+09 | 0.501643E+09 | 2633.52 | 05-NOV-13:50 | 2633.52 | 0.00 |
| December | 0.00 | 0.00 | 0.260560E+09 | 0.260560E+09 | 2029.02 | 01-DEC-14:00 | 2029.02 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.155176E+11 | 0.151596E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.260560E+09 | 0.260560E+09 | 1712.51 | 1712.51 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.316581E+10 | 0.302318E+10 | 3697.35 | 3697.35 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62162806.75 | 0.73 | 115.64 | 05-JAN-08:30 | 1.14 |
| February | 86059920.53 | 0.80 | 118.46 | 12-FEB-05:40 | 1.14 |
| March | 83111932.52 | 0.79 | 131.55 | 19-MAR-07:07 | 1.14 |
| April | 61805969.16 | 0.75 | 95.35 | 17-APR-05:00 | 1.13 |
| May | 20776994.85 | 0.33 | 92.52 | 31-MAY-16:03 | 1.28 |
| June | 0.183469E+09 | 1.16 | 244.42 | 26-JUN-17:20 | 1.22 |
| July | 0.203834E+09 | 1.23 | 211.46 | 15-JUL-17:20 | 1.24 |
| August | 0.228115E+09 | 1.26 | 258.42 | 16-AUG-16:01 | 1.22 |
| September | 0.200513E+09 | 1.17 | 232.80 | 10-SEP-16:05 | 1.23 |
| October | 88854492.49 | 0.73 | 207.41 | 11-OCT-15:10 | 1.25 |
| November | 45548248.59 | 0.55 | 130.68 | 07-NOV-15:10 | 1.28 |
| December | 91559793.17 | 0.79 | 149.03 | 21-DEC-08:05 | 1.14 |
| Annual Sum or Average | 0.135581E+10 | 0.86 | |||
| Minimum of Months | 20776994.85 | 0.33 | 92.52 | 1.13 | |
| Maximum of Months | 0.228115E+09 | 1.26 | 258.42 | 1.28 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.133012E+09 | 1.08 | 126.05 | 05-JAN-08:30 | 1.14 |
| February | 0.143134E+09 | 1.10 | 143.42 | 12-FEB-05:40 | 1.14 |
| March | 0.106789E+09 | 0.92 | 143.31 | 19-MAR-07:01 | 1.14 |
| April | 81864322.03 | 0.90 | 97.74 | 17-APR-05:00 | 1.13 |
| May | 14533771.22 | 0.25 | 78.53 | 31-MAY-17:30 | 1.29 |
| June | 0.169707E+09 | 1.16 | 239.30 | 26-JUN-17:30 | 1.22 |
| July | 0.184906E+09 | 1.22 | 202.93 | 15-JUL-17:30 | 1.24 |
| August | 0.176930E+09 | 1.24 | 222.27 | 16-AUG-16:40 | 1.23 |
| September | 0.123585E+09 | 1.02 | 181.02 | 10-SEP-16:30 | 1.25 |
| October | 39067746.52 | 0.44 | 94.92 | 11-OCT-16:10 | 1.29 |
| November | 76518632.69 | 0.90 | 112.83 | 30-NOV-06:00 | 1.14 |
| December | 0.153147E+09 | 1.07 | 162.12 | 23-DEC-08:00 | 1.14 |
| Annual Sum or Average | 0.140319E+10 | 0.94 | |||
| Minimum of Months | 14533771.22 | 0.25 | 78.53 | 1.13 | |
| Maximum of Months | 0.184906E+09 | 1.24 | 239.30 | 1.29 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.134213E+10 | 1.13 | 501.09 | 01-JAN-00:10 | 1.13 |
| February | 0.121225E+10 | 1.13 | 501.09 | 01-FEB-00:10 | 1.13 |
| March | 0.134213E+10 | 1.13 | 501.09 | 01-MAR-00:10 | 1.13 |
| April | 0.129884E+10 | 1.13 | 501.09 | 01-APR-00:10 | 1.13 |
| May | 0.134213E+10 | 1.13 | 501.09 | 01-MAY-00:10 | 1.13 |
| June | 0.129884E+10 | 1.13 | 501.09 | 01-JUN-00:10 | 1.12 |
| July | 0.134213E+10 | 1.12 | 501.09 | 01-JUL-00:10 | 1.13 |
| August | 0.134213E+10 | 1.12 | 501.09 | 01-AUG-00:10 | 1.11 |
| September | 0.129884E+10 | 1.13 | 501.09 | 01-SEP-00:10 | 1.13 |
| October | 0.134213E+10 | 1.13 | 501.09 | 01-OCT-00:10 | 1.12 |
| November | 0.129884E+10 | 1.13 | 501.09 | 01-NOV-00:10 | 1.13 |
| December | 0.134213E+10 | 1.14 | 501.09 | 01-DEC-00:10 | 1.13 |
| Annual Sum or Average | 0.158025E+11 | 1.13 | |||
| Minimum of Months | 0.121225E+10 | 1.12 | 501.09 | 1.11 | |
| Maximum of Months | 0.134213E+10 | 1.14 | 501.09 | 1.13 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.131781E+09 | 1.09 | 124.05 | 05-JAN-08:30 | 1.14 |
| February | 0.141054E+09 | 1.10 | 144.07 | 12-FEB-05:40 | 1.14 |
| March | 0.102822E+09 | 0.92 | 140.40 | 19-MAR-07:02 | 1.14 |
| April | 77627304.57 | 0.88 | 94.93 | 03-APR-04:00 | 1.13 |
| May | 15210460.81 | 0.27 | 70.51 | 17-MAY-13:30 | 1.29 |
| June | 0.176137E+09 | 1.18 | 199.46 | 26-JUN-17:27 | 1.23 |
| July | 0.198256E+09 | 1.22 | 190.14 | 16-JUL-15:10 | 1.23 |
| August | 0.189002E+09 | 1.25 | 181.33 | 16-AUG-16:13 | 1.24 |
| September | 0.128909E+09 | 1.04 | 154.41 | 09-SEP-13:00 | 1.25 |
| October | 38160536.15 | 0.45 | 88.57 | 31-OCT-24:00 | 1.13 |
| November | 76480578.71 | 0.91 | 112.46 | 30-NOV-06:00 | 1.14 |
| December | 0.150877E+09 | 1.08 | 158.94 | 21-DEC-18:20 | 1.14 |
| Annual Sum or Average | 0.142632E+10 | 0.95 | |||
| Minimum of Months | 15210460.81 | 0.27 | 70.51 | 1.13 | |
| Maximum of Months | 0.198256E+09 | 1.25 | 199.46 | 1.29 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 91450892.41 | 1.07 | 89.77 | 05-JAN-08:30 | 1.14 |
| February | 0.100276E+09 | 1.09 | 102.76 | 12-FEB-05:00 | 1.14 |
| March | 69748126.95 | 0.90 | 92.09 | 19-MAR-07:02 | 1.14 |
| April | 50892996.97 | 0.88 | 64.64 | 03-APR-04:00 | 1.13 |
| May | 10098570.94 | 0.24 | 53.07 | 17-MAY-14:10 | 1.30 |
| June | 0.144447E+09 | 1.21 | 168.88 | 26-JUN-18:00 | 1.23 |
| July | 0.166892E+09 | 1.27 | 151.78 | 16-JUL-15:10 | 1.25 |
| August | 0.152135E+09 | 1.27 | 149.24 | 16-AUG-16:50 | 1.24 |
| September | 0.104607E+09 | 1.07 | 126.25 | 10-SEP-16:03 | 1.26 |
| October | 24082367.34 | 0.39 | 59.99 | 31-OCT-24:00 | 1.13 |
| November | 50637410.29 | 0.86 | 77.53 | 30-NOV-03:10 | 1.14 |
| December | 0.105462E+09 | 1.06 | 116.94 | 23-DEC-08:00 | 1.14 |
| Annual Sum or Average | 0.107073E+10 | 0.94 | |||
| Minimum of Months | 10098570.94 | 0.24 | 53.07 | 1.13 | |
| Maximum of Months | 0.166892E+09 | 1.27 | 168.88 | 1.30 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 91477833.10 | 1.07 | 89.71 | 05-JAN-08:30 | 1.14 |
| February | 0.100259E+09 | 1.09 | 102.85 | 12-FEB-05:00 | 1.14 |
| March | 69611696.08 | 0.90 | 91.96 | 19-MAR-07:02 | 1.14 |
| April | 50674680.96 | 0.87 | 64.66 | 03-APR-04:00 | 1.13 |
| May | 10325169.41 | 0.24 | 54.14 | 17-MAY-13:50 | 1.30 |
| June | 0.144880E+09 | 1.21 | 168.12 | 26-JUN-18:00 | 1.23 |
| July | 0.167605E+09 | 1.27 | 151.93 | 16-JUL-15:10 | 1.24 |
| August | 0.152831E+09 | 1.27 | 148.40 | 16-AUG-16:50 | 1.25 |
| September | 0.105010E+09 | 1.07 | 125.88 | 10-SEP-16:03 | 1.26 |
| October | 24126449.47 | 0.39 | 59.95 | 31-OCT-24:00 | 1.13 |
| November | 50697069.25 | 0.86 | 77.59 | 30-NOV-03:10 | 1.14 |
| December | 0.105466E+09 | 1.06 | 116.87 | 23-DEC-08:00 | 1.14 |
| Annual Sum or Average | 0.107296E+10 | 0.94 | |||
| Minimum of Months | 10325169.41 | 0.24 | 54.14 | 1.13 | |
| Maximum of Months | 0.167605E+09 | 1.27 | 168.12 | 1.30 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 31431489.44 | 0.53 | 77.08 | 05-JAN-08:30 | 1.14 |
| February | 49889578.14 | 0.66 | 78.51 | 12-FEB-04:55 | 1.14 |
| March | 51393044.04 | 0.75 | 99.14 | 14-MAR-13:10 | 1.28 |
| April | 32322640.21 | 0.62 | 61.22 | 17-APR-05:00 | 1.13 |
| May | 18228339.97 | 0.37 | 72.59 | 17-MAY-13:30 | 1.29 |
| June | 0.159434E+09 | 1.22 | 173.81 | 26-JUN-15:10 | 1.24 |
| July | 0.187249E+09 | 1.27 | 161.96 | 16-JUL-15:10 | 1.24 |
| August | 0.205296E+09 | 1.28 | 192.98 | 16-AUG-14:00 | 1.23 |
| September | 0.185382E+09 | 1.20 | 183.55 | 28-SEP-14:00 | 1.24 |
| October | 81101133.30 | 0.76 | 173.45 | 11-OCT-14:10 | 1.24 |
| November | 33779977.95 | 0.46 | 117.10 | 07-NOV-14:00 | 1.27 |
| December | 51295190.01 | 0.64 | 101.70 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.108680E+10 | 0.81 | |||
| Minimum of Months | 18228339.97 | 0.37 | 61.22 | 1.13 | |
| Maximum of Months | 0.205296E+09 | 1.28 | 192.98 | 1.29 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 35290218.76 | 0.56 | 81.80 | 05-JAN-08:30 | 1.14 |
| February | 55316154.98 | 0.68 | 85.15 | 07-FEB-03:00 | 1.14 |
| March | 55602923.95 | 0.76 | 103.54 | 14-MAR-13:10 | 1.28 |
| April | 34418310.70 | 0.62 | 66.74 | 17-APR-05:00 | 1.13 |
| May | 21254443.98 | 0.41 | 77.68 | 17-MAY-13:40 | 1.29 |
| June | 0.175990E+09 | 1.24 | 182.04 | 26-JUN-15:10 | 1.23 |
| July | 0.208813E+09 | 1.28 | 174.89 | 16-JUL-15:10 | 1.24 |
| August | 0.226378E+09 | 1.28 | 199.79 | 16-AUG-14:00 | 1.23 |
| September | 0.203643E+09 | 1.21 | 193.19 | 10-SEP-14:10 | 1.23 |
| October | 88025358.28 | 0.79 | 178.88 | 11-OCT-14:10 | 1.24 |
| November | 35434650.14 | 0.48 | 118.23 | 07-NOV-14:00 | 1.27 |
| December | 55999816.35 | 0.66 | 107.48 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.119617E+10 | 0.83 | |||
| Minimum of Months | 21254443.98 | 0.41 | 66.74 | 1.13 | |
| Maximum of Months | 0.226378E+09 | 1.28 | 199.79 | 1.29 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 99160959.81 | 0.53 | 331.33 | 20-JAN-15:10 | 1.28 |
| February | 0.132491E+09 | 0.64 | 291.18 | 18-FEB-14:30 | 1.28 |
| March | 0.177378E+09 | 0.77 | 457.78 | 13-MAR-16:07 | 1.26 |
| April | 93797842.26 | 0.57 | 283.64 | 08-APR-17:13 | 1.29 |
| May | 0.185385E+09 | 0.79 | 398.70 | 31-MAY-16:15 | 1.26 |
| June | 0.549007E+09 | 1.27 | 625.82 | 26-JUN-17:03 | 1.22 |
| July | 0.571802E+09 | 1.28 | 552.83 | 15-JUL-17:30 | 1.24 |
| August | 0.569483E+09 | 1.27 | 637.14 | 16-AUG-16:01 | 1.22 |
| September | 0.442452E+09 | 1.14 | 554.76 | 28-SEP-15:30 | 1.24 |
| October | 0.222244E+09 | 0.70 | 521.87 | 11-OCT-15:10 | 1.25 |
| November | 0.126913E+09 | 0.56 | 406.40 | 07-NOV-15:00 | 1.27 |
| December | 0.180423E+09 | 0.73 | 309.46 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.335054E+10 | 0.86 | |||
| Minimum of Months | 93797842.26 | 0.53 | 283.64 | 1.14 | |
| Maximum of Months | 0.571802E+09 | 1.28 | 637.14 | 1.29 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.77 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.175619E+09 | 0.93 | 220.86 | 05-JAN-06:00 | 1.14 |
| February | 0.195464E+09 | 0.94 | 268.14 | 12-FEB-05:40 | 1.14 |
| March | 0.139564E+09 | 0.75 | 272.86 | 19-MAR-07:00 | 1.14 |
| April | 82504741.26 | 0.57 | 169.57 | 17-APR-05:00 | 1.13 |
| May | 0.142504E+09 | 0.73 | 374.07 | 31-MAY-17:20 | 1.26 |
| June | 0.520100E+09 | 1.27 | 618.41 | 26-JUN-17:30 | 1.22 |
| July | 0.529850E+09 | 1.28 | 535.79 | 15-JUL-17:30 | 1.24 |
| August | 0.458995E+09 | 1.26 | 557.28 | 16-AUG-16:30 | 1.23 |
| September | 0.278373E+09 | 1.01 | 432.86 | 10-SEP-16:30 | 1.26 |
| October | 89354264.40 | 0.47 | 266.12 | 11-OCT-15:30 | 1.29 |
| November | 0.136761E+09 | 0.79 | 243.16 | 30-NOV-06:00 | 1.14 |
| December | 0.277848E+09 | 1.01 | 327.71 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.302694E+10 | 0.92 | |||
| Minimum of Months | 82504741.26 | 0.47 | 169.57 | 1.13 | |
| Maximum of Months | 0.529850E+09 | 1.28 | 618.41 | 1.29 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 96135075.15 | 0.52 | 304.81 | 20-JAN-14:00 | 1.28 |
| February | 0.134435E+09 | 0.67 | 281.36 | 18-FEB-13:30 | 1.28 |
| March | 0.174023E+09 | 0.76 | 410.88 | 14-MAR-13:00 | 1.26 |
| April | 97206484.94 | 0.59 | 237.47 | 21-APR-12:40 | 1.28 |
| May | 0.196960E+09 | 0.84 | 347.44 | 16-MAY-13:30 | 1.26 |
| June | 0.562443E+09 | 1.27 | 523.97 | 26-JUN-15:10 | 1.23 |
| July | 0.599529E+09 | 1.27 | 499.19 | 16-JUL-14:30 | 1.23 |
| August | 0.593930E+09 | 1.27 | 563.54 | 16-AUG-14:00 | 1.22 |
| September | 0.454054E+09 | 1.14 | 510.94 | 28-SEP-13:40 | 1.23 |
| October | 0.215597E+09 | 0.72 | 464.39 | 11-OCT-14:00 | 1.24 |
| November | 0.125243E+09 | 0.58 | 357.77 | 07-NOV-14:00 | 1.27 |
| December | 0.175462E+09 | 0.74 | 308.57 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.342502E+10 | 0.86 | |||
| Minimum of Months | 96135075.15 | 0.52 | 237.47 | 1.14 | |
| Maximum of Months | 0.599529E+09 | 1.27 | 563.54 | 1.28 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.77 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.174809E+09 | 0.94 | 220.34 | 06-JAN-00:10 | 1.14 |
| February | 0.193300E+09 | 0.94 | 271.56 | 12-FEB-05:40 | 1.14 |
| March | 0.134362E+09 | 0.76 | 267.68 | 19-MAR-06:55 | 1.14 |
| April | 81413898.81 | 0.56 | 163.07 | 17-APR-05:00 | 1.13 |
| May | 0.153106E+09 | 0.81 | 300.80 | 17-MAY-13:30 | 1.27 |
| June | 0.533802E+09 | 1.27 | 492.09 | 26-JUN-17:30 | 1.23 |
| July | 0.558057E+09 | 1.27 | 475.67 | 16-JUL-14:40 | 1.23 |
| August | 0.484601E+09 | 1.26 | 433.41 | 16-AUG-16:13 | 1.24 |
| September | 0.289324E+09 | 1.04 | 345.56 | 09-SEP-13:30 | 1.26 |
| October | 85926569.80 | 0.46 | 193.09 | 11-OCT-14:10 | 1.30 |
| November | 0.137288E+09 | 0.81 | 243.02 | 30-NOV-06:00 | 1.14 |
| December | 0.274200E+09 | 1.01 | 326.13 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.310019E+10 | 0.93 | |||
| Minimum of Months | 81413898.81 | 0.46 | 163.07 | 1.13 | |
| Maximum of Months | 0.558057E+09 | 1.27 | 492.09 | 1.30 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.106110E+09 | 0.85 | 147.16 | 06-JAN-00:10 | 1.14 |
| February | 0.123519E+09 | 0.88 | 181.11 | 12-FEB-04:55 | 1.14 |
| March | 79770744.39 | 0.71 | 166.07 | 19-MAR-06:55 | 1.14 |
| April | 39646598.79 | 0.41 | 104.77 | 17-APR-05:00 | 1.13 |
| May | 0.119555E+09 | 0.84 | 225.70 | 31-MAY-18:00 | 1.27 |
| June | 0.409711E+09 | 1.28 | 402.15 | 26-JUN-18:00 | 1.24 |
| July | 0.437098E+09 | 1.28 | 360.98 | 16-JUL-15:10 | 1.25 |
| August | 0.372227E+09 | 1.28 | 342.55 | 16-AUG-16:17 | 1.25 |
| September | 0.230593E+09 | 1.08 | 269.65 | 10-SEP-16:05 | 1.27 |
| October | 50331529.19 | 0.39 | 156.55 | 11-OCT-15:10 | 1.30 |
| November | 78324879.89 | 0.69 | 156.80 | 30-NOV-06:00 | 1.14 |
| December | 0.171998E+09 | 0.97 | 220.87 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.221888E+10 | 0.89 | |||
| Minimum of Months | 39646598.79 | 0.39 | 104.77 | 1.13 | |
| Maximum of Months | 0.437098E+09 | 1.28 | 402.15 | 1.30 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.77 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.106255E+09 | 0.85 | 147.37 | 06-JAN-00:10 | 1.14 |
| February | 0.123560E+09 | 0.88 | 181.45 | 12-FEB-04:55 | 1.14 |
| March | 79855489.47 | 0.72 | 165.92 | 19-MAR-06:55 | 1.14 |
| April | 39632097.71 | 0.41 | 104.45 | 17-APR-05:00 | 1.13 |
| May | 0.120614E+09 | 0.85 | 224.33 | 17-MAY-13:30 | 1.28 |
| June | 0.410380E+09 | 1.28 | 400.05 | 26-JUN-18:00 | 1.24 |
| July | 0.438255E+09 | 1.28 | 361.38 | 16-JUL-15:10 | 1.25 |
| August | 0.373399E+09 | 1.28 | 340.91 | 16-AUG-16:17 | 1.25 |
| September | 0.231394E+09 | 1.08 | 268.21 | 10-SEP-16:05 | 1.27 |
| October | 50417815.72 | 0.39 | 156.14 | 11-OCT-15:10 | 1.30 |
| November | 78547688.18 | 0.69 | 156.95 | 30-NOV-06:00 | 1.14 |
| December | 0.172058E+09 | 0.97 | 220.96 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.222437E+10 | 0.89 | |||
| Minimum of Months | 39632097.71 | 0.39 | 104.45 | 1.13 | |
| Maximum of Months | 0.438255E+09 | 1.28 | 400.05 | 1.30 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.77 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 81385148.01 | 0.45 | 319.07 | 20-JAN-14:00 | 1.27 |
| February | 95662122.82 | 0.60 | 280.23 | 18-FEB-13:30 | 1.27 |
| March | 0.123582E+09 | 0.69 | 361.88 | 14-MAR-13:00 | 1.26 |
| April | 54333952.50 | 0.49 | 188.31 | 21-APR-13:25 | 1.29 |
| May | 0.164767E+09 | 0.91 | 271.69 | 16-MAY-13:50 | 1.27 |
| June | 0.438832E+09 | 1.28 | 413.70 | 26-JUN-15:10 | 1.24 |
| July | 0.479369E+09 | 1.28 | 383.98 | 16-JUL-15:10 | 1.25 |
| August | 0.483517E+09 | 1.28 | 454.66 | 16-AUG-14:00 | 1.23 |
| September | 0.399837E+09 | 1.20 | 440.70 | 28-SEP-14:00 | 1.24 |
| October | 0.200205E+09 | 0.75 | 420.29 | 11-OCT-14:00 | 1.24 |
| November | 0.111313E+09 | 0.55 | 353.27 | 07-NOV-14:00 | 1.26 |
| December | 0.109395E+09 | 0.59 | 228.71 | 02-DEC-14:30 | 1.29 |
| Annual Sum or Average | 0.274220E+10 | 0.84 | |||
| Minimum of Months | 54333952.50 | 0.45 | 188.31 | 1.23 | |
| Maximum of Months | 0.483517E+09 | 1.28 | 454.66 | 1.29 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.77 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 81702384.47 | 0.45 | 319.56 | 20-JAN-14:00 | 1.27 |
| February | 96558961.64 | 0.60 | 281.71 | 18-FEB-13:30 | 1.27 |
| March | 0.123759E+09 | 0.69 | 363.13 | 14-MAR-13:00 | 1.26 |
| April | 54922087.16 | 0.49 | 190.95 | 21-APR-13:25 | 1.29 |
| May | 0.165807E+09 | 0.91 | 272.94 | 16-MAY-13:40 | 1.27 |
| June | 0.439510E+09 | 1.28 | 413.40 | 26-JUN-15:10 | 1.24 |
| July | 0.480508E+09 | 1.28 | 384.37 | 16-JUL-15:10 | 1.25 |
| August | 0.484592E+09 | 1.28 | 455.00 | 16-AUG-14:00 | 1.23 |
| September | 0.400433E+09 | 1.20 | 441.52 | 28-SEP-13:50 | 1.24 |
| October | 0.200165E+09 | 0.75 | 420.40 | 11-OCT-14:00 | 1.24 |
| November | 0.111544E+09 | 0.55 | 353.53 | 07-NOV-14:00 | 1.26 |
| December | 0.109512E+09 | 0.59 | 228.27 | 02-DEC-14:30 | 1.29 |
| Annual Sum or Average | 0.274901E+10 | 0.84 | |||
| Minimum of Months | 54922087.16 | 0.45 | 190.95 | 1.23 | |
| Maximum of Months | 0.484592E+09 | 1.28 | 455.00 | 1.29 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.78 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.78 | 40.01 | 01-JAN-00:10 | 0.78 |
| February | 96801429.15 | 0.78 | 40.01 | 01-FEB-00:10 | 0.78 |
| March | 0.107173E+09 | 0.78 | 40.01 | 01-MAR-00:10 | 0.78 |
| April | 0.103716E+09 | 0.78 | 40.01 | 01-APR-00:10 | 0.78 |
| May | 0.107173E+09 | 0.78 | 40.01 | 01-MAY-00:10 | 0.77 |
| June | 0.103716E+09 | 0.77 | 40.01 | 01-JUN-00:10 | 0.77 |
| July | 0.107173E+09 | 0.77 | 40.01 | 01-JUL-00:10 | 0.78 |
| August | 0.107173E+09 | 0.77 | 40.01 | 01-AUG-00:10 | 0.77 |
| September | 0.103716E+09 | 0.78 | 40.01 | 01-SEP-00:10 | 0.78 |
| October | 0.107173E+09 | 0.78 | 40.01 | 01-OCT-00:10 | 0.77 |
| November | 0.103716E+09 | 0.78 | 40.01 | 01-NOV-00:10 | 0.78 |
| December | 0.107173E+09 | 0.78 | 40.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.126188E+10 | 0.78 | |||
| Minimum of Months | 96801429.15 | 0.77 | 40.01 | 0.77 | |
| Maximum of Months | 0.107173E+09 | 0.78 | 40.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.142773E+09 | 0.90 | 233.23 | 20-JAN-15:10 | 1.26 |
| February | 0.157591E+09 | 0.93 | 212.30 | 12-FEB-05:40 | 1.14 |
| March | 0.165135E+09 | 0.92 | 279.83 | 13-MAR-15:30 | 1.25 |
| April | 0.126686E+09 | 0.90 | 197.23 | 07-APR-15:30 | 1.27 |
| May | 0.102838E+09 | 0.70 | 270.68 | 31-MAY-16:03 | 1.24 |
| June | 0.297526E+09 | 1.01 | 417.35 | 26-JUN-16:40 | 1.20 |
| July | 0.305730E+09 | 1.07 | 377.83 | 15-JUL-15:20 | 1.22 |
| August | 0.299732E+09 | 1.02 | 431.56 | 16-AUG-16:01 | 1.20 |
| September | 0.223126E+09 | 0.87 | 362.95 | 10-SEP-15:20 | 1.22 |
| October | 0.165417E+09 | 0.89 | 322.45 | 11-OCT-15:10 | 1.24 |
| November | 0.143343E+09 | 0.89 | 255.53 | 05-NOV-15:10 | 1.26 |
| December | 0.206124E+09 | 0.97 | 249.40 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.233602E+10 | 0.92 | |||
| Minimum of Months | 0.102838E+09 | 0.70 | 197.23 | 1.14 | |
| Maximum of Months | 0.305730E+09 | 1.07 | 431.56 | 1.27 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.177783E+09 | 1.02 | 186.02 | 05-JAN-03:00 | 1.14 |
| February | 0.181373E+09 | 1.02 | 221.85 | 12-FEB-05:40 | 1.14 |
| March | 0.142425E+09 | 0.89 | 231.74 | 19-MAR-06:55 | 1.14 |
| April | 0.113593E+09 | 0.87 | 150.01 | 17-APR-05:00 | 1.14 |
| May | 81510416.10 | 0.65 | 249.96 | 31-MAY-16:25 | 1.25 |
| June | 0.281341E+09 | 1.02 | 411.75 | 26-JUN-17:20 | 1.20 |
| July | 0.283028E+09 | 1.08 | 349.90 | 15-JUL-17:30 | 1.22 |
| August | 0.242211E+09 | 1.00 | 383.87 | 16-AUG-16:30 | 1.21 |
| September | 0.145024E+09 | 0.81 | 286.83 | 10-SEP-16:20 | 1.24 |
| October | 0.110755E+09 | 0.81 | 166.94 | 11-OCT-15:30 | 1.28 |
| November | 0.146843E+09 | 0.96 | 197.51 | 30-NOV-06:00 | 1.14 |
| December | 0.246256E+09 | 1.05 | 253.29 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.215214E+10 | 0.93 | |||
| Minimum of Months | 81510416.10 | 0.65 | 150.01 | 1.14 | |
| Maximum of Months | 0.283028E+09 | 1.08 | 411.75 | 1.28 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.138042E+09 | 0.88 | 215.58 | 20-JAN-14:00 | 1.26 |
| February | 0.153925E+09 | 0.93 | 211.53 | 12-FEB-05:40 | 1.14 |
| March | 0.159130E+09 | 0.90 | 249.78 | 14-MAR-13:00 | 1.24 |
| April | 0.122776E+09 | 0.88 | 179.84 | 19-APR-13:30 | 1.27 |
| May | 0.102920E+09 | 0.72 | 233.28 | 16-MAY-13:40 | 1.24 |
| June | 0.301929E+09 | 1.03 | 355.33 | 26-JUN-15:00 | 1.20 |
| July | 0.317945E+09 | 1.09 | 334.97 | 15-JUL-14:00 | 1.21 |
| August | 0.310091E+09 | 1.04 | 387.83 | 16-AUG-14:00 | 1.19 |
| September | 0.225873E+09 | 0.88 | 341.23 | 09-SEP-12:50 | 1.20 |
| October | 0.159345E+09 | 0.90 | 284.40 | 11-OCT-14:00 | 1.23 |
| November | 0.139371E+09 | 0.90 | 225.65 | 05-NOV-13:30 | 1.25 |
| December | 0.200632E+09 | 0.97 | 246.14 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.233198E+10 | 0.93 | |||
| Minimum of Months | 0.102920E+09 | 0.72 | 179.84 | 1.14 | |
| Maximum of Months | 0.317945E+09 | 1.09 | 387.83 | 1.27 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.175469E+09 | 1.03 | 183.58 | 05-JAN-03:00 | 1.14 |
| February | 0.178130E+09 | 1.02 | 220.70 | 12-FEB-05:40 | 1.14 |
| March | 0.134385E+09 | 0.88 | 227.47 | 19-MAR-06:55 | 1.14 |
| April | 0.109377E+09 | 0.83 | 146.74 | 15-APR-05:00 | 1.13 |
| May | 81058903.94 | 0.67 | 191.01 | 17-MAY-13:40 | 1.26 |
| June | 0.286831E+09 | 1.05 | 323.90 | 26-JUN-15:10 | 1.21 |
| July | 0.296123E+09 | 1.09 | 312.71 | 16-JUL-14:40 | 1.21 |
| August | 0.253615E+09 | 1.03 | 302.23 | 16-AUG-14:00 | 1.22 |
| September | 0.146306E+09 | 0.83 | 236.57 | 09-SEP-13:20 | 1.24 |
| October | 0.103613E+09 | 0.75 | 149.92 | 31-OCT-24:00 | 1.13 |
| November | 0.144654E+09 | 0.97 | 195.12 | 30-NOV-06:00 | 1.14 |
| December | 0.241877E+09 | 1.05 | 249.76 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.215144E+10 | 0.93 | |||
| Minimum of Months | 81058903.94 | 0.67 | 146.74 | 1.13 | |
| Maximum of Months | 0.296123E+09 | 1.09 | 323.90 | 1.26 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.130036E+09 | 1.02 | 138.73 | 05-JAN-06:00 | 1.14 |
| February | 0.132250E+09 | 1.03 | 161.22 | 12-FEB-05:40 | 1.14 |
| March | 94373482.71 | 0.83 | 159.52 | 19-MAR-07:00 | 1.14 |
| April | 71801729.09 | 0.78 | 106.82 | 17-APR-05:00 | 1.13 |
| May | 54608207.67 | 0.59 | 150.07 | 31-MAY-16:07 | 1.26 |
| June | 0.223550E+09 | 1.11 | 270.83 | 26-JUN-17:30 | 1.22 |
| July | 0.235157E+09 | 1.15 | 245.56 | 16-JUL-15:10 | 1.23 |
| August | 0.195957E+09 | 1.07 | 247.27 | 16-AUG-16:06 | 1.23 |
| September | 0.111220E+09 | 0.84 | 182.09 | 09-SEP-13:30 | 1.26 |
| October | 69410753.09 | 0.69 | 107.84 | 30-OCT-04:00 | 1.13 |
| November | 0.103243E+09 | 0.93 | 141.80 | 30-NOV-06:00 | 1.14 |
| December | 0.176456E+09 | 1.05 | 185.33 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.159806E+10 | 0.92 | |||
| Minimum of Months | 54608207.67 | 0.59 | 106.82 | 1.13 | |
| Maximum of Months | 0.235157E+09 | 1.15 | 270.83 | 1.26 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.130110E+09 | 1.02 | 138.65 | 05-JAN-06:00 | 1.14 |
| February | 0.132223E+09 | 1.03 | 161.27 | 12-FEB-05:40 | 1.14 |
| March | 94387759.44 | 0.83 | 159.39 | 19-MAR-07:00 | 1.14 |
| April | 71929152.43 | 0.78 | 106.67 | 17-APR-05:00 | 1.13 |
| May | 55297112.88 | 0.60 | 148.70 | 31-MAY-16:07 | 1.26 |
| June | 0.224048E+09 | 1.11 | 268.47 | 26-JUN-17:20 | 1.22 |
| July | 0.235914E+09 | 1.15 | 245.67 | 16-JUL-15:10 | 1.23 |
| August | 0.196729E+09 | 1.07 | 245.52 | 16-AUG-16:07 | 1.23 |
| September | 0.111794E+09 | 0.84 | 183.05 | 09-SEP-13:30 | 1.26 |
| October | 69563088.49 | 0.69 | 107.80 | 30-OCT-04:00 | 1.13 |
| November | 0.103383E+09 | 0.94 | 141.73 | 30-NOV-06:00 | 1.14 |
| December | 0.176421E+09 | 1.05 | 185.27 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.160180E+10 | 0.92 | |||
| Minimum of Months | 55297112.88 | 0.60 | 106.67 | 1.13 | |
| Maximum of Months | 0.235914E+09 | 1.15 | 268.47 | 1.26 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 99764713.08 | 0.84 | 205.88 | 20-JAN-14:00 | 1.25 |
| February | 0.109638E+09 | 0.87 | 181.93 | 18-FEB-14:00 | 1.26 |
| March | 0.115446E+09 | 0.85 | 217.72 | 15-MAR-13:50 | 1.25 |
| April | 81817246.25 | 0.81 | 138.34 | 20-APR-13:00 | 1.28 |
| May | 76170777.18 | 0.66 | 187.38 | 16-MAY-14:00 | 1.26 |
| June | 0.239445E+09 | 1.09 | 294.92 | 26-JUN-15:10 | 1.21 |
| July | 0.257882E+09 | 1.13 | 274.98 | 15-JUL-14:00 | 1.22 |
| August | 0.254195E+09 | 1.09 | 326.64 | 16-AUG-14:00 | 1.20 |
| September | 0.191886E+09 | 0.91 | 290.46 | 28-SEP-13:40 | 1.22 |
| October | 0.123857E+09 | 0.84 | 261.66 | 11-OCT-14:00 | 1.23 |
| November | 0.102878E+09 | 0.83 | 211.25 | 05-NOV-13:50 | 1.25 |
| December | 0.140876E+09 | 0.92 | 181.19 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.179386E+10 | 0.90 | |||
| Minimum of Months | 76170777.18 | 0.66 | 138.34 | 1.14 | |
| Maximum of Months | 0.257882E+09 | 1.13 | 326.64 | 1.28 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.100216E+09 | 0.84 | 206.57 | 20-JAN-14:00 | 1.25 |
| February | 0.110199E+09 | 0.87 | 183.06 | 18-FEB-13:40 | 1.26 |
| March | 0.115795E+09 | 0.85 | 218.82 | 15-MAR-13:50 | 1.25 |
| April | 82253374.48 | 0.82 | 140.74 | 20-APR-13:00 | 1.28 |
| May | 76914745.21 | 0.66 | 188.55 | 16-MAY-13:50 | 1.26 |
| June | 0.239967E+09 | 1.09 | 294.23 | 26-JUN-15:10 | 1.21 |
| July | 0.258626E+09 | 1.13 | 275.33 | 15-JUL-14:00 | 1.22 |
| August | 0.254881E+09 | 1.09 | 326.90 | 16-AUG-14:00 | 1.20 |
| September | 0.192406E+09 | 0.91 | 291.30 | 28-SEP-13:40 | 1.22 |
| October | 0.124225E+09 | 0.84 | 261.75 | 11-OCT-14:00 | 1.23 |
| November | 0.103300E+09 | 0.84 | 211.68 | 05-NOV-13:50 | 1.25 |
| December | 0.141054E+09 | 0.92 | 181.14 | 22-DEC-04:00 | 1.14 |
| Annual Sum or Average | 0.179984E+10 | 0.90 | |||
| Minimum of Months | 76914745.21 | 0.66 | 140.74 | 1.14 | |
| Maximum of Months | 0.258626E+09 | 1.13 | 326.90 | 1.28 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.78 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.78 | 20.01 | 01-JAN-00:10 | 0.78 |
| February | 48400714.57 | 0.78 | 20.01 | 01-FEB-00:10 | 0.78 |
| March | 53586505.42 | 0.78 | 20.01 | 01-MAR-00:10 | 0.78 |
| April | 51857908.47 | 0.78 | 20.01 | 01-APR-00:10 | 0.78 |
| May | 53586505.42 | 0.78 | 20.01 | 01-MAY-00:10 | 0.77 |
| June | 51857908.47 | 0.77 | 20.01 | 01-JUN-00:10 | 0.77 |
| July | 53586505.42 | 0.77 | 20.01 | 01-JUL-00:10 | 0.78 |
| August | 53586505.42 | 0.77 | 20.01 | 01-AUG-00:10 | 0.77 |
| September | 51857908.47 | 0.78 | 20.01 | 01-SEP-00:10 | 0.78 |
| October | 53586505.42 | 0.78 | 20.01 | 01-OCT-00:10 | 0.77 |
| November | 51857908.47 | 0.78 | 20.01 | 01-NOV-00:10 | 0.78 |
| December | 53586505.42 | 0.78 | 20.01 | 01-DEC-00:10 | 0.78 |
| Annual Sum or Average | 0.630938E+09 | 0.78 | |||
| Minimum of Months | 48400714.57 | 0.77 | 20.01 | 0.77 | |
| Maximum of Months | 53586505.42 | 0.78 | 20.01 | 0.78 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 66971460.03 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 86815503.26 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.111443E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 62169577.65 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 66378042.28 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.785073E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.875192E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.975182E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.846039E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.297634E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 89247572.77 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 95972153.25 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.435812E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 62169577.65 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.975182E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.133012E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.143134E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.106789E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 81864322.03 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 34886955.96 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.726205E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.793767E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.756856E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.522379E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 59297939.73 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 76518632.69 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.153147E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.358786E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 34886955.96 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.793767E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.137003E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.121758E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.140441E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.132453E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.149348E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.186760E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.190802E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.200437E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.183374E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.154532E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.137761E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.135302E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.186997E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.121758E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.200437E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.131781E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.141054E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.102822E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 77627304.57 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 39803493.01 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.753410E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.850979E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.808452E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.544812E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 57152503.22 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 76480578.71 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.150877E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.373525E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 39803493.01 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.850979E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 91450892.41 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.100276E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 69748126.95 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 50892996.97 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 28501741.70 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.617788E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.716091E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.650670E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.442051E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 37372689.91 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 50637410.29 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.105462E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.296094E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 28501741.70 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.716091E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 91477833.10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.100259E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 69611696.08 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 50674680.96 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 29493743.98 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.619638E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.719151E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.653645E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.443753E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 37561802.03 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 50697069.25 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.105466E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.297143E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 29493743.98 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.719151E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 41554015.67 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 52493850.03 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 85530318.11 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 32322640.21 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 65650156.50 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.681906E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.803610E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.877387E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.781799E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.301762E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 92228091.35 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 58946869.05 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.387519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 32322640.21 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.877387E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 45693597.96 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 57993917.98 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 92729715.33 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 34418310.70 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 77878853.85 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.752271E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.895498E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.966960E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.858601E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.329886E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 95935432.06 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 63113950.62 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.427098E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 34418310.70 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.966960E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.225266E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.225894E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.469713E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.200132E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.764125E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.234593E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.245219E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.243384E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.186726E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.766305E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.342105E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.250918E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.123437E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.200132E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.245219E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.175619E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.195464E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.177564E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 91193732.10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.580538E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.222210E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.227155E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.196208E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.117627E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.158960E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.137159E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.277848E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.942634E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 91193732.10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.227155E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.211952E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.230666E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.468250E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.221581E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.813292E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.240219E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.257072E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.253789E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.191584E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.741805E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.333263E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.237051E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.126845E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.211952E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.257072E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.174809E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.193300E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.173056E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 98096253.43 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.625930E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.227945E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.239214E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.207118E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.122253E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.148203E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.137433E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.274200E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.979033E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 98096253.43 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.239214E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.106110E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.123519E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.102701E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 42456885.24 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.497739E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.174981E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.187342E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.159084E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.974217E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 96335796.71 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 78460366.22 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.171998E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.740762E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 42456885.24 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.187342E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.106255E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.123560E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.103551E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 43062537.33 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.502178E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.175268E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.187841E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.159587E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.977593E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 96816487.53 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 78693879.37 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.172058E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.743072E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 43062537.33 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.187841E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.272357E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.231079E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.400293E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.147699E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.689652E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.187467E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.205547E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.206602E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.168640E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.759174E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.385262E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.217761E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.107858E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.147699E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.206602E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.273610E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.234012E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.401483E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.150588E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.693988E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.187757E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.206037E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.207063E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.168891E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.759242E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.385959E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.218284E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.108147E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.150588E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.207063E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.229119E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.237738E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.338902E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.227104E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.389689E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.127454E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.131478E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.128406E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.927680E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.435791E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.279031E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.272407E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.721084E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.227104E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.131478E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.178071E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.181587E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.172864E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.140739E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.297423E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.120506E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.121676E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.103787E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.592781E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.154069E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.151458E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.246433E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.557511E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.140739E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.121676E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.215070E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.229286E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.327140E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.222937E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.393120E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.129256E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.136694E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.132804E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.940126E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.414960E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.266014E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.259731E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.725593E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.215070E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.136694E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.175469E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.178155E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.155099E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.136713E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.298224E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.122765E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.127267E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.108642E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.600136E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.132022E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.146870E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.241877E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.565130E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.132022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.127267E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.130036E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.132250E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.103884E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 82661920.44 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.207712E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.957232E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.101072E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.839626E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.460282E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 85685750.53 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.103518E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.176456E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.429006E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 82661920.44 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.101072E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.130110E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.132223E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.104223E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 83471377.08 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.210552E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.959357E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.101398E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.842940E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.462759E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 86086652.71 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.103727E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.176421E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.430585E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 83471377.08 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.101398E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.187463E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.185371E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.258515E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.154586E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.300509E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.102557E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.110889E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.108888E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.803997E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.360054E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.232972E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.208770E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.591558E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.154586E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.110889E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.188927E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.187358E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.260116E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.156602E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.303577E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.102779E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.111209E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.109182E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.806192E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.361493E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.234381E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.209508E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.593987E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.156602E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.111209E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 62162806.75 | 17929408.60 | 0.113661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 86059920.53 | 2806987.65 | 0.160863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 83111932.52 | 0.106968E+09 | 0.138948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 61805969.16 | 1350547.03 | 0.115634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20776994.85 | 0.168898E+09 | 0.122578E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.183469E+09 | 0.220315E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.203834E+09 | 0.247658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.228115E+09 | 0.278847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.200513E+09 | 0.243554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88854492.49 | 0.797272E+09 | 0.426908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 45548248.59 | 0.165232E+09 | 0.594080E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 91559793.17 | 16450927.85 | 0.168998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.135581E+10 | 0.111806E+11 | 0.812460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20776994.85 | 1350547.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.228115E+09 | 0.278847E+10 | 0.168998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.133012E+09 | 0.00 | 0.250777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.143134E+09 | 0.00 | 0.269860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.106789E+09 | 0.00 | 0.201336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81864322.03 | 0.00 | 0.154344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 14533771.22 | 74786014.99 | 0.154830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.169707E+09 | 0.203673E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.184906E+09 | 0.224257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.176930E+09 | 0.215092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.123585E+09 | 0.148582E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 39067746.52 | 75557631.10 | 0.616160E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 76518632.69 | 0.00 | 0.144266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.153147E+09 | 0.00 | 0.288738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140319E+10 | 0.806638E+10 | 0.138642E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 14533771.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.184906E+09 | 0.224257E+10 | 0.288738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.134213E+10 | 0.105329E+09 | 0.207762E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.121225E+10 | 19991017.91 | 0.521829E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134213E+10 | 0.239475E+09 | 0.260056E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129884E+10 | 96619528.79 | 0.168348E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.134213E+10 | 0.575709E+09 | 3546560.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.129884E+10 | 0.214039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.134213E+10 | 0.215718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.134213E+10 | 0.254287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.129884E+10 | 0.208602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.134213E+10 | 0.792741E+09 | 0.107453E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.129884E+10 | 0.303226E+09 | 0.136142E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.134213E+10 | 40900845.92 | 0.546645E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.158025E+11 | 0.111005E+11 | 0.195178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.121225E+10 | 19991017.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134213E+10 | 0.254287E+10 | 0.546645E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.131781E+09 | 0.00 | 0.252387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.141054E+09 | 0.00 | 0.270145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.102822E+09 | 0.00 | 0.196925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 77627304.57 | 0.00 | 0.148672E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 15210460.81 | 90604427.26 | 0.144825E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.176137E+09 | 0.212652E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.198256E+09 | 0.242130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.189002E+09 | 0.231471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.128909E+09 | 0.155641E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 38160536.15 | 70954756.61 | 0.616064E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 76480578.71 | 0.00 | 0.146475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.150877E+09 | 0.00 | 0.288960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.142632E+10 | 0.858050E+10 | 0.137965E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 15210460.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.198256E+09 | 0.242130E+10 | 0.288960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 91450892.41 | 0.00 | 0.177318E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100276E+09 | 0.00 | 0.194428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69748126.95 | 0.00 | 0.135237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 50892996.97 | 0.00 | 0.986784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 10098570.94 | 67712445.75 | 84948335.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.144447E+09 | 0.173807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.166892E+09 | 0.203485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.152135E+09 | 0.185593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.104607E+09 | 0.125827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 24082367.34 | 49498973.70 | 0.385645E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50637410.29 | 0.00 | 0.981829E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105462E+09 | 0.00 | 0.204485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107073E+10 | 0.700432E+10 | 0.955389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 10098570.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.166892E+09 | 0.203485E+10 | 0.204485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 91477833.10 | 0.00 | 0.177447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100259E+09 | 0.00 | 0.194481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69611696.08 | 0.00 | 0.135031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 50674680.96 | 0.00 | 0.982977E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 10325169.41 | 70564174.20 | 84736084.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.144880E+09 | 0.174361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.167605E+09 | 0.204404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.152831E+09 | 0.186490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.105010E+09 | 0.126329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 24126449.47 | 50043925.55 | 0.385779E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50697069.25 | 0.00 | 0.983411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105466E+09 | 0.00 | 0.204581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107296E+10 | 0.703645E+10 | 0.955230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 10325169.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.167605E+09 | 0.204404E+10 | 0.204581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 31431489.44 | 37914866.68 | 0.542115E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 49889578.14 | 9701793.28 | 0.942465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51393044.04 | 0.129208E+09 | 0.779289E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 32322640.21 | 0.00 | 0.620884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 18228339.97 | 0.176156E+09 | 65551217.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.159434E+09 | 0.191983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.187249E+09 | 0.228700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.205296E+09 | 0.251908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.185382E+09 | 0.225676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 81101133.30 | 0.844015E+09 | 0.216539E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 33779977.95 | 0.221588E+09 | 0.293054E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51295190.01 | 28592932.00 | 0.938724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.108680E+10 | 0.104298E+11 | 0.439862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 18228339.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.205296E+09 | 0.251908E+10 | 0.942465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 35290218.76 | 38967454.89 | 0.613984E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 55316154.98 | 9975550.57 | 0.104533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 55602923.95 | 0.140631E+09 | 0.841206E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 34418310.70 | 0.00 | 0.660557E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 21254443.98 | 0.210819E+09 | 68168054.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.175990E+09 | 0.212599E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.208813E+09 | 0.255855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.226378E+09 | 0.278676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.203643E+09 | 0.248591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88025358.28 | 0.926299E+09 | 0.220609E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 35434650.14 | 0.229405E+09 | 0.312080E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 55999816.35 | 26575245.70 | 0.103146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119617E+10 | 0.115399E+11 | 0.479340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21254443.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.226378E+09 | 0.278676E+10 | 0.104533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 99160959.81 | 0.477083E+09 | 0.108205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132491E+09 | 0.352255E+09 | 0.188085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.177378E+09 | 0.111507E+10 | 0.154828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93797842.26 | 0.400077E+09 | 0.109867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.185385E+09 | 0.218790E+10 | 72213357.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.549007E+09 | 0.663232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.571802E+09 | 0.696868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.569483E+09 | 0.695224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.442452E+09 | 0.535407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.222244E+09 | 0.207981E+10 | 0.914611E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.126913E+09 | 0.817544E+09 | 0.107335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.180423E+09 | 0.265542E+09 | 0.288991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.335054E+10 | 0.336026E+11 | 0.105599E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 93797842.26 | 0.265542E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.571802E+09 | 0.696868E+10 | 0.288991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.175619E+09 | 0.00 | 0.321959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.195464E+09 | 0.00 | 0.358341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.139564E+09 | 0.142501E+09 | 0.233771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 82504741.26 | 32386429.39 | 0.146205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.142504E+09 | 0.165070E+10 | 98027090.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.520100E+09 | 0.627949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.529850E+09 | 0.644713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.458995E+09 | 0.557572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.278373E+09 | 0.333165E+10 | 1666102.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 89354264.40 | 0.260453E+09 | 0.123491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.136761E+09 | 1475354.91 | 0.250491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.277848E+09 | 0.00 | 0.509375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.302694E+10 | 0.237215E+11 | 0.195360E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82504741.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.529850E+09 | 0.644713E+10 | 0.509375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 96135075.15 | 0.438315E+09 | 0.110063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.134435E+09 | 0.363748E+09 | 0.192501E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.174023E+09 | 0.112596E+10 | 0.149541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 97206484.94 | 0.468956E+09 | 0.107054E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196960E+09 | 0.233590E+10 | 67888925.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.562443E+09 | 0.683763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.599529E+09 | 0.735711E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.593930E+09 | 0.730706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.454054E+09 | 0.552478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.215597E+09 | 0.201451E+10 | 0.908883E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.125243E+09 | 0.791972E+09 | 0.109863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.175462E+09 | 0.231722E+09 | 0.288839E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.342502E+10 | 0.347977E+11 | 0.105554E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 96135075.15 | 0.231722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.599529E+09 | 0.735711E+10 | 0.288839E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.174809E+09 | 0.00 | 0.324919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.193300E+09 | 0.00 | 0.359288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134362E+09 | 0.145067E+09 | 0.226936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81413898.81 | 62345955.45 | 0.141500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.153106E+09 | 0.178500E+10 | 92444763.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.533802E+09 | 0.648568E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.558057E+09 | 0.683648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.484601E+09 | 0.592959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.289324E+09 | 0.347695E+10 | 217256.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 85926569.80 | 0.232939E+09 | 0.123157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137288E+09 | 539895.96 | 0.255092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.274200E+09 | 0.00 | 0.509658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.310019E+10 | 0.249546E+11 | 0.194982E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 81413898.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.558057E+09 | 0.683648E+10 | 0.509658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.106110E+09 | 0.00 | 0.199663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.123519E+09 | 0.00 | 0.232421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 79770744.39 | 85617171.77 | 0.136421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 39646598.79 | 10432162.01 | 0.729254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.119555E+09 | 0.142446E+10 | 22608957.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.409711E+09 | 0.495180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.437098E+09 | 0.533531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.372227E+09 | 0.453404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.230593E+09 | 0.276194E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50331529.19 | 0.171638E+09 | 0.673677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 78324879.89 | 501537.86 | 0.147300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.171998E+09 | 0.00 | 0.323642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.221888E+10 | 0.192757E+11 | 0.118200E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39646598.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.437098E+09 | 0.533531E+10 | 0.323642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.106255E+09 | 0.00 | 0.200011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.123560E+09 | 0.00 | 0.232585E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 79855489.47 | 88491627.33 | 0.136175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 39632097.71 | 12740481.97 | 0.725558E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.120614E+09 | 0.143731E+10 | 22494909.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.410380E+09 | 0.496067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.438255E+09 | 0.535040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.373399E+09 | 0.454924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.231394E+09 | 0.277182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50417815.72 | 0.173126E+09 | 0.673215E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 78547688.18 | 541173.81 | 0.147769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.172058E+09 | 0.00 | 0.323878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.222437E+10 | 0.193443E+11 | 0.118255E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39632097.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.438255E+09 | 0.535040E+10 | 0.323878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 81385148.01 | 0.724715E+09 | 0.390430E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95662122.82 | 0.512622E+09 | 0.987150E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.123582E+09 | 0.105668E+10 | 0.671022E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 54333952.50 | 0.350894E+09 | 0.463366E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.164767E+09 | 0.198407E+10 | 4938742.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.438832E+09 | 0.530634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.479369E+09 | 0.586044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.483517E+09 | 0.592038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.399837E+09 | 0.484869E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.200205E+09 | 0.214052E+10 | 0.436060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111313E+09 | 0.104444E+10 | 0.458925E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109395E+09 | 0.409922E+09 | 0.140469E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.274220E+10 | 0.301597E+11 | 0.481658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54333952.50 | 0.350894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.483517E+09 | 0.592038E+10 | 0.140469E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 81702384.47 | 0.728327E+09 | 0.390957E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 96558961.64 | 0.520445E+09 | 0.992217E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.123759E+09 | 0.106073E+10 | 0.668565E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 54922087.16 | 0.359624E+09 | 0.460908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.165807E+09 | 0.199677E+10 | 4950039.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.439510E+09 | 0.531544E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.480508E+09 | 0.587549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.484592E+09 | 0.593490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.400433E+09 | 0.485680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.200165E+09 | 0.214118E+10 | 0.434843E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111544E+09 | 0.104636E+10 | 0.460665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109512E+09 | 0.411510E+09 | 0.140496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.274901E+10 | 0.302476E+11 | 0.481807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54922087.16 | 0.359624E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.484592E+09 | 0.593490E+10 | 0.140496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.142773E+09 | 0.328123E+09 | 0.209008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.157591E+09 | 0.304030E+09 | 0.239397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.165135E+09 | 0.666092E+09 | 0.199297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.126686E+09 | 0.380593E+09 | 0.171806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.102838E+09 | 0.108845E+10 | 0.232725E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.297526E+09 | 0.360129E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.305730E+09 | 0.372885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.299732E+09 | 0.366475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.223126E+09 | 0.265101E+10 | 89091786.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.165417E+09 | 0.103842E+10 | 0.144576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143343E+09 | 0.518086E+09 | 0.181727E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.206124E+09 | 0.251775E+09 | 0.335260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.233602E+10 | 0.182215E+11 | 0.151325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.102838E+09 | 0.251775E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.305730E+09 | 0.372885E+10 | 0.335260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.177783E+09 | 1067560.36 | 0.322048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.181373E+09 | 795429.87 | 0.328596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.142425E+09 | 0.114577E+09 | 0.240638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113593E+09 | 0.101842E+09 | 0.190282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81510416.10 | 0.815275E+09 | 0.251245E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.281341E+09 | 0.339727E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283028E+09 | 0.343995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.242211E+09 | 0.293674E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.145024E+09 | 0.165677E+10 | 0.120377E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.110755E+09 | 0.162404E+09 | 0.175919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.146843E+09 | 17201250.45 | 0.263486E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.246256E+09 | 657353.21 | 0.446212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.215214E+10 | 0.126445E+11 | 0.200434E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 81510416.10 | 657353.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.283028E+09 | 0.343995E+10 | 0.446212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.138042E+09 | 0.293110E+09 | 0.209193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.153925E+09 | 0.286666E+09 | 0.239401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.159130E+09 | 0.646339E+09 | 0.194897E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.122776E+09 | 0.381122E+09 | 0.167597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.102920E+09 | 0.110536E+10 | 0.218221E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.301929E+09 | 0.368857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.317945E+09 | 0.391810E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.310091E+09 | 0.383504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.225873E+09 | 0.271087E+10 | 84924190.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.159345E+09 | 0.984505E+09 | 0.144421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.139371E+09 | 0.484778E+09 | 0.182691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.200632E+09 | 0.224571E+09 | 0.334887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.233198E+10 | 0.185590E+11 | 0.150340E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.102920E+09 | 0.224571E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.317945E+09 | 0.391810E+10 | 0.334887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.175469E+09 | 0.00 | 0.323384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.178130E+09 | 92659.89 | 0.328275E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134385E+09 | 77831833.78 | 0.235564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.109377E+09 | 0.102730E+09 | 0.185610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81058903.94 | 0.821897E+09 | 0.239423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.286831E+09 | 0.349395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.296123E+09 | 0.363393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.253615E+09 | 0.310540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.146306E+09 | 0.168759E+10 | 0.111556E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.103613E+09 | 0.106305E+09 | 0.174425E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.144654E+09 | 8229329.41 | 0.265300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.241877E+09 | 0.00 | 0.445773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.215144E+10 | 0.130380E+11 | 0.199343E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 81058903.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.296123E+09 | 0.363393E+10 | 0.445773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.130036E+09 | 0.00 | 0.241216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132250E+09 | 0.00 | 0.245322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 94373482.71 | 35567215.83 | 0.169468E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 71801729.09 | 40583745.06 | 0.126807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 54608207.67 | 0.576150E+09 | 0.123727E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.223550E+09 | 0.269925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.235157E+09 | 0.286529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.195957E+09 | 0.237944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.111220E+09 | 0.128968E+10 | 62602021.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 69410753.09 | 60574538.35 | 0.119233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103243E+09 | 1020203.24 | 0.191352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.176456E+09 | 0.00 | 0.327324E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.159806E+10 | 0.994756E+10 | 0.143935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54608207.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.235157E+09 | 0.286529E+10 | 0.327324E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.130110E+09 | 0.00 | 0.241533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132223E+09 | 0.00 | 0.245455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 94387759.44 | 36794472.75 | 0.169430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 71929152.43 | 43145800.88 | 0.126737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 55297112.88 | 0.584377E+09 | 0.124026E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.224048E+09 | 0.270629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.235914E+09 | 0.287563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.196729E+09 | 0.238982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.111794E+09 | 0.129707E+10 | 62358603.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 69563088.49 | 61512407.36 | 0.119460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103383E+09 | 1275830.97 | 0.191714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.176421E+09 | 0.00 | 0.327503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.160180E+10 | 0.999592E+10 | 0.144047E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 55297112.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.235914E+09 | 0.287563E+10 | 0.327503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 99764713.08 | 0.333782E+09 | 0.133296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.109638E+09 | 0.287800E+09 | 0.158599E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.115446E+09 | 0.548414E+09 | 0.129810E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81817246.25 | 0.275394E+09 | 0.108827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76170777.18 | 0.849694E+09 | 0.107597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.239445E+09 | 0.289988E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.257882E+09 | 0.315533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.254195E+09 | 0.311801E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.191886E+09 | 0.230946E+10 | 41862376.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.123857E+09 | 0.907903E+09 | 0.909306E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.102878E+09 | 0.497693E+09 | 0.114186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.140876E+09 | 0.258349E+09 | 0.221064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.179386E+10 | 0.154417E+11 | 0.971659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76170777.18 | 0.258349E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.257882E+09 | 0.315533E+10 | 0.221064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.100216E+09 | 0.337744E+09 | 0.133632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.110199E+09 | 0.293345E+09 | 0.158916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.115795E+09 | 0.553458E+09 | 0.129817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 82253374.48 | 0.281505E+09 | 0.108787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76914745.21 | 0.858774E+09 | 0.107886E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.239967E+09 | 0.290746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.258626E+09 | 0.316581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.254881E+09 | 0.312806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.192406E+09 | 0.231690E+10 | 41854868.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.124225E+09 | 0.912368E+09 | 0.910502E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103300E+09 | 0.501643E+09 | 0.114473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.141054E+09 | 0.260560E+09 | 0.221224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.179984E+10 | 0.155176E+11 | 0.972873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76914745.21 | 0.260560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.258626E+09 | 0.316581E+10 | 0.221224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 62162806.75 | 0.00 | 0.00 | 0.00 | 4808653.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 86059920.53 | 0.00 | 0.00 | 0.00 | 755582.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 83111932.52 | 0.00 | 0.00 | 0.00 | 28331038.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 61805969.16 | 0.00 | 0.00 | 0.00 | 363608.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20776994.85 | 0.00 | 0.00 | 0.00 | 45601047.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.183469E+09 | 0.00 | 0.00 | 0.00 | 0.601605E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.203834E+09 | 0.00 | 0.00 | 0.00 | 0.671358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.228115E+09 | 0.00 | 0.00 | 0.00 | 0.747067E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.200513E+09 | 0.00 | 0.00 | 0.00 | 0.645527E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88854492.49 | 0.00 | 0.00 | 0.00 | 0.208780E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 45548248.59 | 0.00 | 0.00 | 0.00 | 43699324.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 91559793.17 | 0.00 | 0.00 | 0.00 | 4412360.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.135581E+10 | 0.00 | 0.00 | 0.00 | 0.300231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20776994.85 | 0.00 | 0.00 | 0.00 | 363608.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.228115E+09 | 0.00 | 0.00 | 0.00 | 0.747067E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.133012E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.143134E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.106789E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81864322.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 14533771.22 | 0.00 | 0.00 | 0.00 | 20353184.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.169707E+09 | 0.00 | 0.00 | 0.00 | 0.556497E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.184906E+09 | 0.00 | 0.00 | 0.00 | 0.608860E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.176930E+09 | 0.00 | 0.00 | 0.00 | 0.579927E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.123585E+09 | 0.00 | 0.00 | 0.00 | 0.398793E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 39067746.52 | 0.00 | 0.00 | 0.00 | 20230193.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 76518632.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.153147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140319E+10 | 0.00 | 0.00 | 0.00 | 0.218466E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 14533771.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.184906E+09 | 0.00 | 0.00 | 0.00 | 0.608860E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 27901647.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.121225E+10 | 0.00 | 0.00 | 0.00 | 5328481.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 62273382.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129884E+10 | 0.00 | 0.00 | 0.00 | 25687782.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 0.151348E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.129884E+10 | 0.00 | 0.00 | 0.00 | 0.568763E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 0.565892E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 0.662240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.129884E+10 | 0.00 | 0.00 | 0.00 | 0.534906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 0.203189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.129884E+10 | 0.00 | 0.00 | 0.00 | 78775373.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 10887077.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.158025E+11 | 0.00 | 0.00 | 0.00 | 0.289719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.121225E+10 | 0.00 | 0.00 | 0.00 | 5328481.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134213E+10 | 0.00 | 0.00 | 0.00 | 0.662240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.131781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.141054E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.102822E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 77627304.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 15210460.81 | 0.00 | 0.00 | 0.00 | 24593032.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.176137E+09 | 0.00 | 0.00 | 0.00 | 0.577273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.198256E+09 | 0.00 | 0.00 | 0.00 | 0.652723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.189002E+09 | 0.00 | 0.00 | 0.00 | 0.619450E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.128909E+09 | 0.00 | 0.00 | 0.00 | 0.415902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 38160536.15 | 0.00 | 0.00 | 0.00 | 18991967.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 76480578.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.150877E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.142632E+10 | 0.00 | 0.00 | 0.00 | 0.230893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 15210460.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.198256E+09 | 0.00 | 0.00 | 0.00 | 0.652723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 91450892.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100276E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69748126.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 50892996.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 10098570.94 | 0.00 | 0.00 | 0.00 | 18403170.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.144447E+09 | 0.00 | 0.00 | 0.00 | 0.473341E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.166892E+09 | 0.00 | 0.00 | 0.00 | 0.549199E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.152135E+09 | 0.00 | 0.00 | 0.00 | 0.498535E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.104607E+09 | 0.00 | 0.00 | 0.00 | 0.337445E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 24082367.34 | 0.00 | 0.00 | 0.00 | 13290322.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50637410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105462E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107073E+10 | 0.00 | 0.00 | 0.00 | 0.189021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 10098570.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.166892E+09 | 0.00 | 0.00 | 0.00 | 0.549199E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 91477833.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100259E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69611696.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 50674680.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 10325169.41 | 0.00 | 0.00 | 0.00 | 19168574.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.144880E+09 | 0.00 | 0.00 | 0.00 | 0.474757E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.167605E+09 | 0.00 | 0.00 | 0.00 | 0.551546E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.152831E+09 | 0.00 | 0.00 | 0.00 | 0.500815E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.105010E+09 | 0.00 | 0.00 | 0.00 | 0.338742E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 24126449.47 | 0.00 | 0.00 | 0.00 | 13435352.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50697069.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105466E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107296E+10 | 0.00 | 0.00 | 0.00 | 0.189846E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 10325169.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.167605E+09 | 0.00 | 0.00 | 0.00 | 0.551546E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 31431489.44 | 0.00 | 0.00 | 0.00 | 10122526.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 49889578.14 | 0.00 | 0.00 | 0.00 | 2604271.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51393044.04 | 0.00 | 0.00 | 0.00 | 34137274.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 32322640.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 18228339.97 | 0.00 | 0.00 | 0.00 | 47421816.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.159434E+09 | 0.00 | 0.00 | 0.00 | 0.522472E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.187249E+09 | 0.00 | 0.00 | 0.00 | 0.616361E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.205296E+09 | 0.00 | 0.00 | 0.00 | 0.672091E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.185382E+09 | 0.00 | 0.00 | 0.00 | 0.596417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 81101133.30 | 0.00 | 0.00 | 0.00 | 0.220661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 33779977.95 | 0.00 | 0.00 | 0.00 | 58448113.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51295190.01 | 0.00 | 0.00 | 0.00 | 7651679.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.108680E+10 | 0.00 | 0.00 | 0.00 | 0.278839E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 18228339.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.205296E+09 | 0.00 | 0.00 | 0.00 | 0.672091E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 35290218.76 | 0.00 | 0.00 | 0.00 | 10403379.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 55316154.98 | 0.00 | 0.00 | 0.00 | 2677763.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 55602923.95 | 0.00 | 0.00 | 0.00 | 37126791.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 34418310.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 21254443.98 | 0.00 | 0.00 | 0.00 | 56624409.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.175990E+09 | 0.00 | 0.00 | 0.00 | 0.576281E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.208813E+09 | 0.00 | 0.00 | 0.00 | 0.686684E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.226378E+09 | 0.00 | 0.00 | 0.00 | 0.740582E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.203643E+09 | 0.00 | 0.00 | 0.00 | 0.654958E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88025358.28 | 0.00 | 0.00 | 0.00 | 0.241861E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 35434650.14 | 0.00 | 0.00 | 0.00 | 60500781.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 55999816.35 | 0.00 | 0.00 | 0.00 | 7114134.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119617E+10 | 0.00 | 0.00 | 0.00 | 0.307481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21254443.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.226378E+09 | 0.00 | 0.00 | 0.00 | 0.740582E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 99160959.81 | 0.00 | 0.00 | 0.00 | 0.126105E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132491E+09 | 0.00 | 0.00 | 0.00 | 93403272.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.177378E+09 | 0.00 | 0.00 | 0.00 | 0.292334E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93797842.26 | 0.00 | 0.00 | 0.00 | 0.106335E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.185385E+09 | 0.00 | 0.00 | 0.00 | 0.578739E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.549007E+09 | 0.00 | 0.00 | 0.00 | 0.179693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.571802E+09 | 0.00 | 0.00 | 0.00 | 0.188038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.569483E+09 | 0.00 | 0.00 | 0.00 | 0.186436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.442452E+09 | 0.00 | 0.00 | 0.00 | 0.142481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.222244E+09 | 0.00 | 0.00 | 0.00 | 0.544061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.126913E+09 | 0.00 | 0.00 | 0.00 | 0.215192E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.180423E+09 | 0.00 | 0.00 | 0.00 | 70495441.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.335054E+10 | 0.00 | 0.00 | 0.00 | 0.899314E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 93797842.26 | 0.00 | 0.00 | 0.00 | 70495441.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.571802E+09 | 0.00 | 0.00 | 0.00 | 0.188038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.175619E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.195464E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.139564E+09 | 0.00 | 0.00 | 0.00 | 38000128.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 82504741.26 | 0.00 | 0.00 | 0.00 | 8688990.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.142504E+09 | 0.00 | 0.00 | 0.00 | 0.438034E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.520100E+09 | 0.00 | 0.00 | 0.00 | 0.170200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.529850E+09 | 0.00 | 0.00 | 0.00 | 0.174170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.458995E+09 | 0.00 | 0.00 | 0.00 | 0.150308E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.278373E+09 | 0.00 | 0.00 | 0.00 | 0.897902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 89354264.40 | 0.00 | 0.00 | 0.00 | 69605544.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.136761E+09 | 0.00 | 0.00 | 0.00 | 397880.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.277848E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.302694E+10 | 0.00 | 0.00 | 0.00 | 0.639941E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 82504741.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.529850E+09 | 0.00 | 0.00 | 0.00 | 0.174170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 96135075.15 | 0.00 | 0.00 | 0.00 | 0.115817E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.134435E+09 | 0.00 | 0.00 | 0.00 | 96231289.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.174023E+09 | 0.00 | 0.00 | 0.00 | 0.294226E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 97206484.94 | 0.00 | 0.00 | 0.00 | 0.124374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196960E+09 | 0.00 | 0.00 | 0.00 | 0.616332E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.562443E+09 | 0.00 | 0.00 | 0.00 | 0.183974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.599529E+09 | 0.00 | 0.00 | 0.00 | 0.197119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.593930E+09 | 0.00 | 0.00 | 0.00 | 0.194396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.454054E+09 | 0.00 | 0.00 | 0.00 | 0.146178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.215597E+09 | 0.00 | 0.00 | 0.00 | 0.526208E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.125243E+09 | 0.00 | 0.00 | 0.00 | 0.208020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.175462E+09 | 0.00 | 0.00 | 0.00 | 61589240.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.342502E+10 | 0.00 | 0.00 | 0.00 | 0.925947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 96135075.15 | 0.00 | 0.00 | 0.00 | 61589240.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.599529E+09 | 0.00 | 0.00 | 0.00 | 0.197119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.174809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.193300E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134362E+09 | 0.00 | 0.00 | 0.00 | 38693884.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81413898.81 | 0.00 | 0.00 | 0.00 | 16682354.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.153106E+09 | 0.00 | 0.00 | 0.00 | 0.472824E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.533802E+09 | 0.00 | 0.00 | 0.00 | 0.174564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.558057E+09 | 0.00 | 0.00 | 0.00 | 0.183408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.484601E+09 | 0.00 | 0.00 | 0.00 | 0.158658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.289324E+09 | 0.00 | 0.00 | 0.00 | 0.933206E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 85926569.80 | 0.00 | 0.00 | 0.00 | 62276581.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137288E+09 | 0.00 | 0.00 | 0.00 | 145836.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.274200E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.310019E+10 | 0.00 | 0.00 | 0.00 | 0.669014E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 81413898.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.558057E+09 | 0.00 | 0.00 | 0.00 | 0.183408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.106110E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.123519E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 79770744.39 | 0.00 | 0.00 | 0.00 | 22930327.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 39646598.79 | 0.00 | 0.00 | 0.00 | 2810286.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.119555E+09 | 0.00 | 0.00 | 0.00 | 0.378184E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.409711E+09 | 0.00 | 0.00 | 0.00 | 0.134010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.437098E+09 | 0.00 | 0.00 | 0.00 | 0.143633E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.372227E+09 | 0.00 | 0.00 | 0.00 | 0.121862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.230593E+09 | 0.00 | 0.00 | 0.00 | 0.743625E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50331529.19 | 0.00 | 0.00 | 0.00 | 46004267.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 78324879.89 | 0.00 | 0.00 | 0.00 | 135486.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.171998E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.221888E+10 | 0.00 | 0.00 | 0.00 | 0.518874E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39646598.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.437098E+09 | 0.00 | 0.00 | 0.00 | 0.143633E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.106255E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.123560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 79855489.47 | 0.00 | 0.00 | 0.00 | 23695293.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 39632097.71 | 0.00 | 0.00 | 0.00 | 3430439.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.120614E+09 | 0.00 | 0.00 | 0.00 | 0.381563E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.410380E+09 | 0.00 | 0.00 | 0.00 | 0.134230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.438255E+09 | 0.00 | 0.00 | 0.00 | 0.144015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.373399E+09 | 0.00 | 0.00 | 0.00 | 0.122247E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.231394E+09 | 0.00 | 0.00 | 0.00 | 0.746199E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50417815.72 | 0.00 | 0.00 | 0.00 | 46398671.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 78547688.18 | 0.00 | 0.00 | 0.00 | 146191.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.172058E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.222437E+10 | 0.00 | 0.00 | 0.00 | 0.520635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39632097.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.438255E+09 | 0.00 | 0.00 | 0.00 | 0.144015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 81385148.01 | 0.00 | 0.00 | 0.00 | 0.190972E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95662122.82 | 0.00 | 0.00 | 0.00 | 0.135417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.123582E+09 | 0.00 | 0.00 | 0.00 | 0.276711E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 54333952.50 | 0.00 | 0.00 | 0.00 | 93364591.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.164767E+09 | 0.00 | 0.00 | 0.00 | 0.524885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.438832E+09 | 0.00 | 0.00 | 0.00 | 0.143584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.479369E+09 | 0.00 | 0.00 | 0.00 | 0.157610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.483517E+09 | 0.00 | 0.00 | 0.00 | 0.158251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.399837E+09 | 0.00 | 0.00 | 0.00 | 0.128656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.200205E+09 | 0.00 | 0.00 | 0.00 | 0.558969E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111313E+09 | 0.00 | 0.00 | 0.00 | 0.273949E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109395E+09 | 0.00 | 0.00 | 0.00 | 0.108366E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.274220E+10 | 0.00 | 0.00 | 0.00 | 0.804364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54333952.50 | 0.00 | 0.00 | 0.00 | 93364591.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.483517E+09 | 0.00 | 0.00 | 0.00 | 0.158251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 81702384.47 | 0.00 | 0.00 | 0.00 | 0.191908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 96558961.64 | 0.00 | 0.00 | 0.00 | 0.137453E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.123759E+09 | 0.00 | 0.00 | 0.00 | 0.277724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 54922087.16 | 0.00 | 0.00 | 0.00 | 95665946.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.165807E+09 | 0.00 | 0.00 | 0.00 | 0.528181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.439510E+09 | 0.00 | 0.00 | 0.00 | 0.143806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.480508E+09 | 0.00 | 0.00 | 0.00 | 0.157987E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.484592E+09 | 0.00 | 0.00 | 0.00 | 0.158604E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.400433E+09 | 0.00 | 0.00 | 0.00 | 0.128848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.200165E+09 | 0.00 | 0.00 | 0.00 | 0.559077E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111544E+09 | 0.00 | 0.00 | 0.00 | 0.274415E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109512E+09 | 0.00 | 0.00 | 0.00 | 0.108772E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.274901E+10 | 0.00 | 0.00 | 0.00 | 0.806564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54922087.16 | 0.00 | 0.00 | 0.00 | 95665946.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.484592E+09 | 0.00 | 0.00 | 0.00 | 0.158604E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.142773E+09 | 0.00 | 0.00 | 0.00 | 86346577.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.157591E+09 | 0.00 | 0.00 | 0.00 | 80147057.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.165135E+09 | 0.00 | 0.00 | 0.00 | 0.173767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.126686E+09 | 0.00 | 0.00 | 0.00 | 0.100418E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.102838E+09 | 0.00 | 0.00 | 0.00 | 0.286851E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.297526E+09 | 0.00 | 0.00 | 0.00 | 0.977017E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.305730E+09 | 0.00 | 0.00 | 0.00 | 0.100905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.299732E+09 | 0.00 | 0.00 | 0.00 | 0.984328E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.223126E+09 | 0.00 | 0.00 | 0.00 | 0.704554E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.165417E+09 | 0.00 | 0.00 | 0.00 | 0.270374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143343E+09 | 0.00 | 0.00 | 0.00 | 0.135688E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.206124E+09 | 0.00 | 0.00 | 0.00 | 66282396.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.233602E+10 | 0.00 | 0.00 | 0.00 | 0.487482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.102838E+09 | 0.00 | 0.00 | 0.00 | 66282396.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.305730E+09 | 0.00 | 0.00 | 0.00 | 0.100905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.177783E+09 | 0.00 | 0.00 | 0.00 | 287914.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.181373E+09 | 0.00 | 0.00 | 0.00 | 214702.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.142425E+09 | 0.00 | 0.00 | 0.00 | 30439384.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113593E+09 | 0.00 | 0.00 | 0.00 | 27145984.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81510416.10 | 0.00 | 0.00 | 0.00 | 0.215912E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.281341E+09 | 0.00 | 0.00 | 0.00 | 0.923714E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283028E+09 | 0.00 | 0.00 | 0.00 | 0.933729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.242211E+09 | 0.00 | 0.00 | 0.00 | 0.795662E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.145024E+09 | 0.00 | 0.00 | 0.00 | 0.447757E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.110755E+09 | 0.00 | 0.00 | 0.00 | 43313868.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.146843E+09 | 0.00 | 0.00 | 0.00 | 4615040.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.246256E+09 | 0.00 | 0.00 | 0.00 | 177361.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.215214E+10 | 0.00 | 0.00 | 0.00 | 0.342297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 81510416.10 | 0.00 | 0.00 | 0.00 | 177361.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.283028E+09 | 0.00 | 0.00 | 0.00 | 0.933729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.138042E+09 | 0.00 | 0.00 | 0.00 | 77027232.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.153925E+09 | 0.00 | 0.00 | 0.00 | 75360926.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.159130E+09 | 0.00 | 0.00 | 0.00 | 0.168010E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.122776E+09 | 0.00 | 0.00 | 0.00 | 0.100161E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.102920E+09 | 0.00 | 0.00 | 0.00 | 0.290200E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.301929E+09 | 0.00 | 0.00 | 0.00 | 0.990635E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.317945E+09 | 0.00 | 0.00 | 0.00 | 0.104900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.310091E+09 | 0.00 | 0.00 | 0.00 | 0.101795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.225873E+09 | 0.00 | 0.00 | 0.00 | 0.714253E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.159345E+09 | 0.00 | 0.00 | 0.00 | 0.255615E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.139371E+09 | 0.00 | 0.00 | 0.00 | 0.126644E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.200632E+09 | 0.00 | 0.00 | 0.00 | 59099193.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.233198E+10 | 0.00 | 0.00 | 0.00 | 0.492395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.102920E+09 | 0.00 | 0.00 | 0.00 | 59099193.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.317945E+09 | 0.00 | 0.00 | 0.00 | 0.104900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.175469E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.178130E+09 | 0.00 | 0.00 | 0.00 | 25044.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134385E+09 | 0.00 | 0.00 | 0.00 | 20713675.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.109377E+09 | 0.00 | 0.00 | 0.00 | 27335578.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81058903.94 | 0.00 | 0.00 | 0.00 | 0.217165E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.286831E+09 | 0.00 | 0.00 | 0.00 | 0.940820E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.296123E+09 | 0.00 | 0.00 | 0.00 | 0.976547E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.253615E+09 | 0.00 | 0.00 | 0.00 | 0.832804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.146306E+09 | 0.00 | 0.00 | 0.00 | 0.453830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.103613E+09 | 0.00 | 0.00 | 0.00 | 28408806.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.144654E+09 | 0.00 | 0.00 | 0.00 | 2215173.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.241877E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.215144E+10 | 0.00 | 0.00 | 0.00 | 0.349986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 81058903.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.296123E+09 | 0.00 | 0.00 | 0.00 | 0.976547E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.130036E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132250E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 94373482.71 | 0.00 | 0.00 | 0.00 | 9510583.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 71801729.09 | 0.00 | 0.00 | 0.00 | 10860191.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 54608207.67 | 0.00 | 0.00 | 0.00 | 0.153103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.223550E+09 | 0.00 | 0.00 | 0.00 | 0.733682E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.235157E+09 | 0.00 | 0.00 | 0.00 | 0.775560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.195957E+09 | 0.00 | 0.00 | 0.00 | 0.643669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.111220E+09 | 0.00 | 0.00 | 0.00 | 0.349062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 69410753.09 | 0.00 | 0.00 | 0.00 | 16274997.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103243E+09 | 0.00 | 0.00 | 0.00 | 275491.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.176456E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.159806E+10 | 0.00 | 0.00 | 0.00 | 0.269200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54608207.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.235157E+09 | 0.00 | 0.00 | 0.00 | 0.775560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.130110E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132223E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 94387759.44 | 0.00 | 0.00 | 0.00 | 9835269.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 71929152.43 | 0.00 | 0.00 | 0.00 | 11542224.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 55297112.88 | 0.00 | 0.00 | 0.00 | 0.155255E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.224048E+09 | 0.00 | 0.00 | 0.00 | 0.735309E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.235914E+09 | 0.00 | 0.00 | 0.00 | 0.778064E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.196729E+09 | 0.00 | 0.00 | 0.00 | 0.646211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.111794E+09 | 0.00 | 0.00 | 0.00 | 0.350965E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 69563088.49 | 0.00 | 0.00 | 0.00 | 16523564.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103383E+09 | 0.00 | 0.00 | 0.00 | 344455.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.176421E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.160180E+10 | 0.00 | 0.00 | 0.00 | 0.270405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 55297112.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.235914E+09 | 0.00 | 0.00 | 0.00 | 0.778064E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 99764713.08 | 0.00 | 0.00 | 0.00 | 87697808.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.109638E+09 | 0.00 | 0.00 | 0.00 | 75733007.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.115446E+09 | 0.00 | 0.00 | 0.00 | 0.143069E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81817246.25 | 0.00 | 0.00 | 0.00 | 72769134.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76170777.18 | 0.00 | 0.00 | 0.00 | 0.224339E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.239445E+09 | 0.00 | 0.00 | 0.00 | 0.786124E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.257882E+09 | 0.00 | 0.00 | 0.00 | 0.851009E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.254195E+09 | 0.00 | 0.00 | 0.00 | 0.834689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.191886E+09 | 0.00 | 0.00 | 0.00 | 0.612110E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.123857E+09 | 0.00 | 0.00 | 0.00 | 0.236197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.102878E+09 | 0.00 | 0.00 | 0.00 | 0.130095E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.140876E+09 | 0.00 | 0.00 | 0.00 | 67893646.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.179386E+10 | 0.00 | 0.00 | 0.00 | 0.412172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76170777.18 | 0.00 | 0.00 | 0.00 | 67893646.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.257882E+09 | 0.00 | 0.00 | 0.00 | 0.851009E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.100216E+09 | 0.00 | 0.00 | 0.00 | 88711931.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.110199E+09 | 0.00 | 0.00 | 0.00 | 77159519.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.115795E+09 | 0.00 | 0.00 | 0.00 | 0.144321E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 82253374.48 | 0.00 | 0.00 | 0.00 | 74349098.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76914745.21 | 0.00 | 0.00 | 0.00 | 0.226663E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.239967E+09 | 0.00 | 0.00 | 0.00 | 0.787827E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.258626E+09 | 0.00 | 0.00 | 0.00 | 0.853468E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.254881E+09 | 0.00 | 0.00 | 0.00 | 0.836944E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.192406E+09 | 0.00 | 0.00 | 0.00 | 0.613787E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.124225E+09 | 0.00 | 0.00 | 0.00 | 0.237268E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103300E+09 | 0.00 | 0.00 | 0.00 | 0.131082E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.141054E+09 | 0.00 | 0.00 | 0.00 | 68454399.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.179984E+10 | 0.00 | 0.00 | 0.00 | 0.414003E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76914745.21 | 0.00 | 0.00 | 0.00 | 68454399.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.258626E+09 | 0.00 | 0.00 | 0.00 | 0.853468E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.746892E+09 | 0.00 | 0.00 | 69188.68 | 0.00 | 0.674288E+09 | 16895211.70 | 0.00 | 0.35 |
| February | 0.509606E+09 | 0.00 | 0.00 | 20533.48 | 0.00 | 0.830800E+09 | 12026070.46 | 0.00 | 0.35 |
| March | 0.369514E+09 | 0.00 | 0.00 | 283616.28 | 0.00 | 0.757845E+09 | 45561037.08 | 0.00 | 0.35 |
| April | 0.381702E+09 | 0.00 | 0.00 | 7669.39 | 1572.48 | 0.645566E+09 | 2924178.50 | 0.00 | 0.35 |
| May | 0.530103E+09 | 7414626.20 | 0.00 | 211682.57 | 811714.61 | 73740829.83 | 44992322.10 | 0.00 | 0.35 |
| June | 42338154.25 | 0.134961E+09 | 0.00 | 1277978.53 | 0.00 | 0.00 | 0.206051E+09 | 0.00 | 0.35 |
| July | 9119776.30 | 0.155936E+09 | 0.00 | 1436065.04 | 0.00 | 0.00 | 0.193836E+09 | 0.00 | 0.35 |
| August | 6209427.23 | 0.118051E+09 | 0.00 | 2187695.69 | 0.00 | 0.00 | 0.231168E+09 | 0.00 | 0.35 |
| September | 83620157.34 | 45659410.83 | 0.00 | 3077899.32 | 0.00 | 0.00 | 0.341872E+09 | 0.00 | 0.35 |
| October | 0.546997E+09 | 988173.93 | 0.00 | 2009038.96 | 0.00 | 0.235728E+09 | 0.335888E+09 | 0.00 | 0.35 |
| November | 0.857703E+09 | 0.00 | 0.00 | 502373.79 | 0.00 | 0.324922E+09 | 0.109117E+09 | 0.00 | 0.35 |
| December | 0.615132E+09 | 0.00 | 0.00 | 62779.83 | 0.00 | 0.916125E+09 | 19129043.04 | 0.00 | 0.35 |
| Annual Sum or Average | 0.469894E+10 | 0.463010E+09 | 0.00 | 11146521.53 | 813287.09 | 0.445902E+10 | 0.155946E+10 | 0.00 | 0.35 |
| Minimum of Months | 6209427.23 | 0.00 | 0.00 | 7669.39 | 0.00 | 0.00 | 2924178.50 | 0.00 | 0.35 |
| Maximum of Months | 0.857703E+09 | 0.155936E+09 | 0.00 | 3077899.32 | 811714.61 | 0.916125E+09 | 0.341872E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 79043996.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132612E+10 | 0.00 | 0.00 | 0.35 |
| February | 47962430.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128202E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.161409E+09 | 0.00 | 0.00 | 0.00 | 97785.69 | 0.972507E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.148770E+09 | 0.00 | 0.00 | 0.00 | 92210.70 | 0.861365E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.530345E+09 | 6018284.16 | 0.00 | 65797.57 | 2146957.05 | 83154602.49 | 14108933.63 | 0.00 | 0.35 |
| June | 45609632.92 | 0.129982E+09 | 0.00 | 1238954.54 | 0.00 | 0.00 | 0.203495E+09 | 0.00 | 0.35 |
| July | 11085845.97 | 0.152101E+09 | 0.00 | 1356323.58 | 0.00 | 0.00 | 0.195331E+09 | 0.00 | 0.35 |
| August | 15590711.68 | 0.112021E+09 | 0.00 | 1722266.84 | 0.00 | 0.00 | 0.231029E+09 | 0.00 | 0.35 |
| September | 0.149433E+09 | 44930722.81 | 0.00 | 1768306.50 | 0.00 | 0.00 | 0.272194E+09 | 0.00 | 0.35 |
| October | 0.643368E+09 | 761346.31 | 0.00 | 173315.28 | 0.00 | 0.369761E+09 | 44016419.73 | 0.00 | 0.35 |
| November | 0.374347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.847905E+09 | 0.00 | 0.00 | 0.35 |
| December | 74472195.05 | 0.00 | 0.00 | 0.00 | 81575.32 | 0.144594E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.228144E+10 | 0.445814E+09 | 0.00 | 6324964.31 | 2418528.76 | 0.718878E+10 | 0.960173E+09 | 0.00 | 0.35 |
| Minimum of Months | 11085845.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.643368E+09 | 0.152101E+09 | 0.00 | 1768306.50 | 2146957.05 | 0.144594E+10 | 0.272194E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.177891E+10 | 0.00 | 0.00 | 146572.04 | 0.00 | 0.164884E+09 | 68708743.90 | 0.00 | 0.51 |
| February | 0.146258E+10 | 0.00 | 0.00 | 28949.22 | 0.00 | 0.369045E+09 | 28244459.99 | 0.00 | 0.51 |
| March | 0.139641E+10 | 0.00 | 0.00 | 343806.55 | 0.00 | 0.180864E+09 | 80982356.63 | 0.00 | 0.51 |
| April | 0.131120E+10 | 0.00 | 0.00 | 93659.67 | 0.00 | 0.109455E+09 | 53880223.65 | 0.00 | 0.51 |
| May | 0.906262E+09 | 1885959.59 | 0.00 | 648952.90 | 141240.84 | 6239753.91 | 0.152979E+09 | 0.00 | 0.52 |
| June | 0.485463E+09 | 75639683.74 | 0.00 | 1147529.96 | 15121713.91 | 0.00 | 35190602.74 | 0.00 | 0.52 |
| July | 0.474237E+09 | 86072175.74 | 0.00 | 1055016.17 | 15432477.48 | 0.00 | 26120644.01 | 0.00 | 0.52 |
| August | 0.520234E+09 | 55769654.49 | 0.00 | 2072619.33 | 11719111.85 | 0.00 | 68578614.89 | 0.00 | 0.52 |
| September | 0.730078E+09 | 15161453.63 | 0.00 | 2388899.72 | 1169021.66 | 0.00 | 0.109867E+09 | 0.00 | 0.52 |
| October | 0.147814E+10 | 50926.98 | 0.00 | 1350576.87 | 0.00 | 78101547.51 | 0.189471E+09 | 0.00 | 0.52 |
| November | 0.165533E+10 | 0.00 | 0.00 | 491073.92 | 0.00 | 0.127535E+09 | 0.113197E+09 | 0.00 | 0.52 |
| December | 0.172212E+10 | 0.00 | 0.00 | 57745.30 | 0.00 | 0.386831E+09 | 44919847.33 | 0.00 | 0.51 |
| Annual Sum or Average | 0.139210E+11 | 0.234580E+09 | 0.00 | 9825401.66 | 43583565.74 | 0.142296E+10 | 0.972140E+09 | 0.00 | 0.52 |
| Minimum of Months | 0.474237E+09 | 0.00 | 0.00 | 28949.22 | 0.00 | 0.00 | 26120644.01 | 0.00 | 0.51 |
| Maximum of Months | 0.177891E+10 | 86072175.74 | 0.00 | 2388899.72 | 15432477.48 | 0.386831E+09 | 0.189471E+09 | 0.00 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 62094262.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134244E+10 | 0.00 | 0.00 | 0.35 |
| February | 54438312.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127519E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.169802E+09 | 0.00 | 0.00 | 0.00 | 29895.80 | 0.964209E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.195492E+09 | 0.00 | 0.00 | 0.00 | 74313.77 | 0.815831E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.539753E+09 | 6140954.50 | 0.00 | 73165.17 | 1458417.15 | 80405190.49 | 14186265.32 | 0.00 | 0.35 |
| June | 41592802.07 | 0.131292E+09 | 0.00 | 1439495.64 | 0.00 | 0.00 | 0.206111E+09 | 0.00 | 0.35 |
| July | 9397677.40 | 0.154871E+09 | 0.00 | 1517051.09 | 0.00 | 0.00 | 0.195031E+09 | 0.00 | 0.35 |
| August | 7978247.40 | 0.114822E+09 | 0.00 | 1982639.88 | 0.00 | 0.00 | 0.235133E+09 | 0.00 | 0.35 |
| September | 0.144123E+09 | 44687051.52 | 0.00 | 1915443.27 | 0.00 | 0.00 | 0.278424E+09 | 0.00 | 0.35 |
| October | 0.652123E+09 | 749795.10 | 0.00 | 138472.18 | 0.00 | 0.364719E+09 | 37872900.45 | 0.00 | 0.35 |
| November | 0.358419E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863386E+09 | 0.00 | 0.00 | 0.35 |
| December | 63331851.91 | 0.00 | 0.00 | 0.00 | 100818.88 | 0.145632E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.229854E+10 | 0.452563E+09 | 0.00 | 7066267.24 | 1663445.60 | 0.716251E+10 | 0.966758E+09 | 0.00 | 0.35 |
| Minimum of Months | 7978247.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.652123E+09 | 0.154871E+09 | 0.00 | 1982639.88 | 1458417.15 | 0.145632E+10 | 0.278424E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.213472E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119519E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.144278E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119011E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.231817E+09 | 0.00 | 0.00 | 0.00 | 133573.93 | 0.907536E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.397285E+09 | 0.00 | 0.00 | 0.00 | 128249.23 | 0.618179E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.571005E+09 | 5462879.44 | 0.00 | 81225.12 | 2436120.72 | 60695666.78 | 26095833.71 | 0.00 | 0.35 |
| June | 20821336.88 | 0.126543E+09 | 0.00 | 1325405.70 | 0.00 | 0.00 | 0.229716E+09 | 0.00 | 0.35 |
| July | 1752487.62 | 0.150013E+09 | 0.00 | 1468482.65 | 0.00 | 0.00 | 0.200287E+09 | 0.00 | 0.35 |
| August | 3118392.10 | 0.109803E+09 | 0.00 | 1743191.62 | 0.00 | 0.00 | 0.242386E+09 | 0.00 | 0.35 |
| September | 0.136222E+09 | 43533642.10 | 0.00 | 1716745.74 | 0.00 | 0.00 | 0.294703E+09 | 0.00 | 0.35 |
| October | 0.793110E+09 | 688497.95 | 0.00 | 123923.83 | 0.00 | 0.232015E+09 | 50230292.09 | 0.00 | 0.35 |
| November | 0.678776E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.548117E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.245458E+09 | 0.00 | 0.00 | 0.00 | 95471.27 | 0.128061E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.343711E+10 | 0.436044E+09 | 0.00 | 6458974.65 | 2793415.15 | 0.603246E+10 | 0.104342E+10 | 0.00 | 0.35 |
| Minimum of Months | 1752487.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.793110E+09 | 0.150013E+09 | 0.00 | 1743191.62 | 2436120.72 | 0.128061E+10 | 0.294703E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.211468E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119719E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.145916E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118847E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.232190E+09 | 0.00 | 0.00 | 0.00 | 124843.02 | 0.907290E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.399913E+09 | 0.00 | 0.00 | 0.00 | 124823.53 | 0.615717E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.571159E+09 | 5494488.84 | 0.00 | 85078.74 | 2346332.86 | 60695205.68 | 27010081.45 | 0.00 | 0.35 |
| June | 20564657.26 | 0.126593E+09 | 0.00 | 1331123.80 | 0.00 | 0.00 | 0.229873E+09 | 0.00 | 0.35 |
| July | 1618632.22 | 0.150150E+09 | 0.00 | 1474366.70 | 0.00 | 0.00 | 0.200251E+09 | 0.00 | 0.35 |
| August | 2892988.97 | 0.109930E+09 | 0.00 | 1751374.88 | 0.00 | 0.00 | 0.242370E+09 | 0.00 | 0.35 |
| September | 0.135640E+09 | 43524020.06 | 0.00 | 1723967.16 | 0.00 | 0.00 | 0.295355E+09 | 0.00 | 0.35 |
| October | 0.791570E+09 | 688074.82 | 0.00 | 124957.13 | 0.00 | 0.233165E+09 | 50249115.74 | 0.00 | 0.35 |
| November | 0.677633E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.549263E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.243834E+09 | 0.00 | 0.00 | 0.00 | 94986.21 | 0.128221E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.343440E+10 | 0.436380E+09 | 0.00 | 6490868.40 | 2690985.62 | 0.603400E+10 | 0.104511E+10 | 0.00 | 0.35 |
| Minimum of Months | 1618632.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.791570E+09 | 0.150150E+09 | 0.00 | 1751374.88 | 2346332.86 | 0.128221E+10 | 0.295355E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.118616E+10 | 0.00 | 0.00 | 160519.37 | 0.00 | 0.231761E+09 | 51474792.46 | 0.00 | 0.35 |
| February | 0.804989E+09 | 0.00 | 0.00 | 53220.89 | 0.00 | 0.544542E+09 | 22965129.75 | 0.00 | 0.35 |
| March | 0.621869E+09 | 0.00 | 0.00 | 352831.00 | 0.00 | 0.495188E+09 | 73981593.65 | 0.00 | 0.35 |
| April | 0.667485E+09 | 0.00 | 0.00 | 160.12 | 5593.63 | 0.374832E+09 | 438759.15 | 0.00 | 0.35 |
| May | 0.545718E+09 | 7029297.59 | 0.00 | 300462.23 | 958651.97 | 41523548.34 | 95670892.88 | 0.00 | 0.35 |
| June | 10405794.59 | 0.132167E+09 | 0.00 | 1396028.64 | 0.00 | 0.00 | 0.238626E+09 | 0.00 | 0.35 |
| July | 1280687.10 | 0.154335E+09 | 0.00 | 1563378.09 | 0.00 | 0.00 | 0.196858E+09 | 0.00 | 0.35 |
| August | 535628.03 | 0.116587E+09 | 0.00 | 2246468.75 | 0.00 | 0.00 | 0.233952E+09 | 0.00 | 0.35 |
| September | 53789971.39 | 44356705.35 | 0.00 | 3149357.72 | 0.00 | 0.00 | 0.379083E+09 | 0.00 | 0.35 |
| October | 0.532889E+09 | 919794.95 | 0.00 | 2331283.54 | 0.00 | 0.135620E+09 | 0.474128E+09 | 0.00 | 0.35 |
| November | 0.962687E+09 | 0.00 | 0.00 | 809422.06 | 0.00 | 0.150582E+09 | 0.214560E+09 | 0.00 | 0.35 |
| December | 0.101001E+10 | 0.00 | 0.00 | 132347.04 | 0.00 | 0.517299E+09 | 47408113.54 | 0.00 | 0.35 |
| Annual Sum or Average | 0.639782E+10 | 0.455396E+09 | 0.00 | 12495479.45 | 964245.61 | 0.249135E+10 | 0.202915E+10 | 0.00 | 0.35 |
| Minimum of Months | 535628.03 | 0.00 | 0.00 | 160.12 | 0.00 | 0.00 | 438759.15 | 0.00 | 0.35 |
| Maximum of Months | 0.118616E+10 | 0.154335E+09 | 0.00 | 3149357.72 | 958651.97 | 0.544542E+09 | 0.474128E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.112499E+10 | 0.00 | 0.00 | 163419.49 | 0.00 | 0.290493E+09 | 51883604.52 | 0.00 | 0.35 |
| February | 0.759962E+09 | 0.00 | 0.00 | 52491.12 | 0.00 | 0.589360E+09 | 22265866.82 | 0.00 | 0.35 |
| March | 0.595461E+09 | 0.00 | 0.00 | 380422.18 | 0.00 | 0.515723E+09 | 79791310.26 | 0.00 | 0.35 |
| April | 0.651456E+09 | 0.00 | 0.00 | 204.31 | 5973.43 | 0.391082E+09 | 597690.60 | 0.00 | 0.35 |
| May | 0.513777E+09 | 7008075.36 | 0.00 | 403276.54 | 929819.51 | 46035939.43 | 0.128759E+09 | 0.00 | 0.35 |
| June | 8049108.80 | 0.133179E+09 | 0.00 | 1606935.04 | 0.00 | 0.00 | 0.236397E+09 | 0.00 | 0.35 |
| July | 200726.83 | 0.156827E+09 | 0.00 | 1784231.42 | 0.00 | 0.00 | 0.191802E+09 | 0.00 | 0.35 |
| August | 0.00 | 0.118351E+09 | 0.00 | 2534961.70 | 0.00 | 0.00 | 0.227020E+09 | 0.00 | 0.35 |
| September | 48105404.21 | 44264330.68 | 0.00 | 3504844.89 | 0.00 | 0.00 | 0.383524E+09 | 0.00 | 0.35 |
| October | 0.483317E+09 | 909408.74 | 0.00 | 2546741.94 | 0.00 | 0.139045E+09 | 0.522501E+09 | 0.00 | 0.35 |
| November | 0.951165E+09 | 0.00 | 0.00 | 838057.15 | 0.00 | 0.155614E+09 | 0.221271E+09 | 0.00 | 0.35 |
| December | 0.941753E+09 | 0.00 | 0.00 | 125723.55 | 0.00 | 0.586191E+09 | 45004642.32 | 0.00 | 0.35 |
| Annual Sum or Average | 0.607823E+10 | 0.460539E+09 | 0.00 | 13941309.32 | 935792.94 | 0.271354E+10 | 0.211082E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 204.31 | 0.00 | 0.00 | 597690.60 | 0.00 | 0.35 |
| Maximum of Months | 0.112499E+10 | 0.156827E+09 | 0.00 | 3504844.89 | 929819.51 | 0.589360E+09 | 0.522501E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.205906E+10 | 0.00 | 0.00 | 1601163.08 | 0.00 | 0.561073E+09 | 0.359599E+09 | 0.00 | 0.35 |
| February | 0.148514E+10 | 0.00 | 0.00 | 1194560.59 | 0.00 | 0.102255E+10 | 0.275328E+09 | 0.00 | 0.35 |
| March | 0.113965E+10 | 0.00 | 0.00 | 2761680.90 | 0.00 | 0.913322E+09 | 0.359525E+09 | 0.00 | 0.35 |
| April | 0.129644E+10 | 0.00 | 0.00 | 1178303.79 | 0.00 | 0.657437E+09 | 0.207650E+09 | 0.00 | 0.35 |
| May | 0.667552E+09 | 16271791.54 | 0.00 | 4159574.57 | 0.00 | 32671800.50 | 0.706162E+09 | 0.00 | 0.35 |
| June | 3821662.89 | 0.282441E+09 | 0.00 | 4247058.96 | 0.00 | 0.00 | 0.452149E+09 | 0.00 | 0.35 |
| July | 2783498.38 | 0.330264E+09 | 0.00 | 4063766.89 | 0.00 | 0.00 | 0.363399E+09 | 0.00 | 0.35 |
| August | 3542162.59 | 0.243680E+09 | 0.00 | 5223843.25 | 0.00 | 0.00 | 0.451072E+09 | 0.00 | 0.35 |
| September | 0.194060E+09 | 93716526.32 | 0.00 | 6221275.53 | 0.00 | 0.00 | 0.645191E+09 | 0.00 | 0.35 |
| October | 0.108462E+10 | 2175857.70 | 0.00 | 4823561.51 | 0.00 | 0.527153E+09 | 0.608992E+09 | 0.00 | 0.35 |
| November | 0.164097E+10 | 0.00 | 0.00 | 2360965.13 | 0.00 | 0.558596E+09 | 0.417060E+09 | 0.00 | 0.35 |
| December | 0.145032E+10 | 0.00 | 0.00 | 753729.43 | 0.00 | 0.152943E+10 | 0.151732E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.110280E+11 | 0.968549E+09 | 0.00 | 38589483.62 | 0.00 | 0.580223E+10 | 0.499786E+10 | 0.00 | 0.35 |
| Minimum of Months | 2783498.38 | 0.00 | 0.00 | 753729.43 | 0.00 | 0.00 | 0.151732E+09 | 0.00 | 0.35 |
| Maximum of Months | 0.205906E+10 | 0.330264E+09 | 0.00 | 6221275.53 | 0.00 | 0.152943E+10 | 0.706162E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.899144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192029E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.656803E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200842E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.813831E+09 | 0.00 | 0.00 | 423454.72 | 0.00 | 0.144320E+10 | 81314952.41 | 0.00 | 0.35 |
| April | 0.120639E+10 | 0.00 | 0.00 | 124657.50 | 0.00 | 0.855100E+09 | 31174086.42 | 0.00 | 0.35 |
| May | 0.718691E+09 | 14548089.91 | 0.00 | 3291515.75 | 0.00 | 54990307.54 | 0.625693E+09 | 0.00 | 0.35 |
| June | 2787025.07 | 0.273867E+09 | 0.00 | 4260992.30 | 0.00 | 0.00 | 0.453157E+09 | 0.00 | 0.35 |
| July | 1766846.68 | 0.323722E+09 | 0.00 | 3990642.92 | 0.00 | 0.00 | 0.367601E+09 | 0.00 | 0.35 |
| August | 14942064.02 | 0.233638E+09 | 0.00 | 4343506.69 | 0.00 | 0.00 | 0.451690E+09 | 0.00 | 0.35 |
| September | 0.308661E+09 | 92915449.14 | 0.00 | 3707337.94 | 0.00 | 0.00 | 0.522059E+09 | 0.00 | 0.35 |
| October | 0.127700E+10 | 1767704.71 | 0.00 | 611487.06 | 0.00 | 0.711488E+09 | 0.127005E+09 | 0.00 | 0.35 |
| November | 0.988535E+09 | 0.00 | 0.00 | 5864.59 | 0.00 | 0.146595E+10 | 4878696.90 | 0.00 | 0.35 |
| December | 0.387495E+09 | 0.00 | 0.00 | 0.00 | 9927.28 | 0.264963E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.727605E+10 | 0.940458E+09 | 0.00 | 20759459.47 | 9927.28 | 0.111091E+11 | 0.266457E+10 | 0.00 | 0.35 |
| Minimum of Months | 1766846.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.127700E+10 | 0.323722E+09 | 0.00 | 4343506.69 | 9927.28 | 0.264963E+10 | 0.625693E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.203807E+10 | 0.00 | 0.00 | 1479264.25 | 0.00 | 0.576087E+09 | 0.367636E+09 | 0.00 | 0.35 |
| February | 0.144467E+10 | 0.00 | 0.00 | 1190889.38 | 0.00 | 0.103044E+10 | 0.312070E+09 | 0.00 | 0.35 |
| March | 0.113889E+10 | 0.00 | 0.00 | 2761639.02 | 0.00 | 0.903087E+09 | 0.375859E+09 | 0.00 | 0.35 |
| April | 0.128816E+10 | 0.00 | 0.00 | 1292170.39 | 0.00 | 0.640685E+09 | 0.242024E+09 | 0.00 | 0.35 |
| May | 0.627322E+09 | 16005598.86 | 0.00 | 4616888.69 | 0.00 | 30245488.45 | 0.753090E+09 | 0.00 | 0.35 |
| June | 7276257.14 | 0.284753E+09 | 0.00 | 4845842.72 | 0.00 | 0.00 | 0.447051E+09 | 0.00 | 0.35 |
| July | 1236074.70 | 0.334698E+09 | 0.00 | 4474308.14 | 0.00 | 0.00 | 0.363696E+09 | 0.00 | 0.35 |
| August | 1995847.99 | 0.248187E+09 | 0.00 | 5937638.06 | 0.00 | 0.00 | 0.447566E+09 | 0.00 | 0.35 |
| September | 0.186187E+09 | 93038804.94 | 0.00 | 6716842.58 | 0.00 | 0.00 | 0.653714E+09 | 0.00 | 0.35 |
| October | 0.106436E+10 | 2133276.33 | 0.00 | 4637939.93 | 0.00 | 0.526701E+09 | 0.632166E+09 | 0.00 | 0.35 |
| November | 0.162671E+10 | 0.00 | 0.00 | 2290126.14 | 0.00 | 0.577819E+09 | 0.410615E+09 | 0.00 | 0.35 |
| December | 0.144486E+10 | 0.00 | 0.00 | 682966.83 | 0.00 | 0.153370E+10 | 0.154252E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.108697E+11 | 0.978815E+09 | 0.00 | 40926516.13 | 0.00 | 0.581877E+10 | 0.515974E+10 | 0.00 | 0.35 |
| Minimum of Months | 1236074.70 | 0.00 | 0.00 | 682966.83 | 0.00 | 0.00 | 0.154252E+09 | 0.00 | 0.35 |
| Maximum of Months | 0.203807E+10 | 0.334698E+09 | 0.00 | 6716842.58 | 0.00 | 0.153370E+10 | 0.753090E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.852038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196468E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.667874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199799E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.869086E+09 | 0.00 | 0.00 | 412759.45 | 0.00 | 0.138019E+10 | 92543704.27 | 0.00 | 0.35 |
| April | 0.122436E+10 | 0.00 | 0.00 | 197278.43 | 0.00 | 0.824991E+09 | 53342924.23 | 0.00 | 0.35 |
| May | 0.650192E+09 | 14332626.27 | 0.00 | 3745476.78 | 0.00 | 59616010.57 | 0.694549E+09 | 0.00 | 0.35 |
| June | 5794514.37 | 0.276545E+09 | 0.00 | 4856898.13 | 0.00 | 0.00 | 0.448719E+09 | 0.00 | 0.35 |
| July | 3343166.10 | 0.328664E+09 | 0.00 | 4393568.02 | 0.00 | 0.00 | 0.364695E+09 | 0.00 | 0.35 |
| August | 6343697.59 | 0.239018E+09 | 0.00 | 5088589.41 | 0.00 | 0.00 | 0.454914E+09 | 0.00 | 0.35 |
| September | 0.291180E+09 | 92289757.87 | 0.00 | 4120446.29 | 0.00 | 0.00 | 0.541939E+09 | 0.00 | 0.35 |
| October | 0.131339E+10 | 1733268.27 | 0.00 | 456298.58 | 0.00 | 0.702668E+09 | 96083018.70 | 0.00 | 0.35 |
| November | 0.958220E+09 | 0.00 | 0.00 | 3082.44 | 0.00 | 0.149709E+10 | 2606821.69 | 0.00 | 0.35 |
| December | 0.386254E+09 | 0.00 | 0.00 | 0.00 | 31267.24 | 0.264852E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.722807E+10 | 0.952583E+09 | 0.00 | 23274397.52 | 31267.24 | 0.110758E+11 | 0.274939E+10 | 0.00 | 0.35 |
| Minimum of Months | 3343166.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.131339E+10 | 0.328664E+09 | 0.00 | 5088589.41 | 31267.24 | 0.264852E+10 | 0.694549E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.171968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111328E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.116113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151668E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.152234E+10 | 0.00 | 0.00 | 291219.17 | 0.00 | 0.739354E+09 | 94658065.93 | 0.00 | 0.35 |
| April | 0.170609E+10 | 0.00 | 0.00 | 73478.56 | 0.00 | 0.383538E+09 | 32237284.21 | 0.00 | 0.35 |
| May | 0.546258E+09 | 13599837.73 | 0.00 | 3568603.42 | 129979.38 | 0.00 | 0.885368E+09 | 0.00 | 0.35 |
| June | 716653.77 | 0.263980E+09 | 0.00 | 4017715.89 | 0.00 | 0.00 | 0.463322E+09 | 0.00 | 0.35 |
| July | 0.00 | 0.314079E+09 | 0.00 | 3830207.02 | 0.00 | 0.00 | 0.372358E+09 | 0.00 | 0.35 |
| August | 3676881.99 | 0.226886E+09 | 0.00 | 4184756.26 | 0.00 | 0.00 | 0.465094E+09 | 0.00 | 0.35 |
| September | 0.258662E+09 | 89472817.60 | 0.00 | 3652192.80 | 0.00 | 0.00 | 0.595118E+09 | 0.00 | 0.35 |
| October | 0.158812E+10 | 1588017.70 | 0.00 | 412548.56 | 0.00 | 0.424928E+09 | 0.152382E+09 | 0.00 | 0.35 |
| November | 0.174032E+10 | 0.00 | 0.00 | 12617.52 | 0.00 | 0.732310E+09 | 6752949.14 | 0.00 | 0.35 |
| December | 0.110450E+10 | 0.00 | 0.00 | 0.00 | 36428.81 | 0.194837E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.113515E+11 | 0.909606E+09 | 0.00 | 20043339.21 | 166408.19 | 0.685846E+10 | 0.306729E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.174032E+10 | 0.314079E+09 | 0.00 | 4184756.26 | 129979.38 | 0.194837E+10 | 0.885368E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.171848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111429E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.116089E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151715E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.152285E+10 | 0.00 | 0.00 | 298549.50 | 0.00 | 0.738365E+09 | 95690898.83 | 0.00 | 0.35 |
| April | 0.171496E+10 | 0.00 | 0.00 | 81887.91 | 0.00 | 0.372691E+09 | 35662152.10 | 0.00 | 0.35 |
| May | 0.543295E+09 | 13592324.72 | 0.00 | 3595068.08 | 125047.18 | 0.00 | 0.888672E+09 | 0.00 | 0.35 |
| June | 716843.25 | 0.264081E+09 | 0.00 | 4027235.95 | 0.00 | 0.00 | 0.463300E+09 | 0.00 | 0.35 |
| July | 0.00 | 0.314285E+09 | 0.00 | 3836949.35 | 0.00 | 0.00 | 0.372268E+09 | 0.00 | 0.35 |
| August | 3225387.09 | 0.227091E+09 | 0.00 | 4199298.82 | 0.00 | 0.00 | 0.465312E+09 | 0.00 | 0.35 |
| September | 0.257381E+09 | 89448387.05 | 0.00 | 3666141.42 | 0.00 | 0.00 | 0.596580E+09 | 0.00 | 0.35 |
| October | 0.159226E+10 | 1586459.09 | 0.00 | 410708.48 | 0.00 | 0.424264E+09 | 0.148089E+09 | 0.00 | 0.35 |
| November | 0.173771E+10 | 0.00 | 0.00 | 12796.44 | 0.00 | 0.734954E+09 | 6754117.47 | 0.00 | 0.35 |
| December | 0.110268E+10 | 0.00 | 0.00 | 0.00 | 35769.73 | 0.195007E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.113544E+11 | 0.910085E+09 | 0.00 | 20128635.95 | 160816.91 | 0.685178E+10 | 0.307233E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.173771E+10 | 0.314285E+09 | 0.00 | 4199298.82 | 125047.18 | 0.195007E+10 | 0.888672E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.221753E+10 | 0.00 | 0.00 | 2712863.58 | 0.00 | 0.159352E+09 | 0.698575E+09 | 0.00 | 0.35 |
| February | 0.179419E+10 | 0.00 | 0.00 | 1822839.44 | 0.00 | 0.570203E+09 | 0.483104E+09 | 0.00 | 0.35 |
| March | 0.167529E+10 | 0.00 | 0.00 | 2834292.72 | 0.00 | 0.278884E+09 | 0.505142E+09 | 0.00 | 0.35 |
| April | 0.173217E+10 | 0.00 | 0.00 | 1146191.08 | 0.00 | 0.215624E+09 | 0.273065E+09 | 0.00 | 0.35 |
| May | 0.463420E+09 | 15567664.98 | 0.00 | 4503539.66 | 0.00 | 0.00 | 0.975970E+09 | 0.00 | 0.35 |
| June | 1380816.52 | 0.273912E+09 | 0.00 | 4035004.53 | 0.00 | 0.00 | 0.462098E+09 | 0.00 | 0.35 |
| July | 436767.89 | 0.321820E+09 | 0.00 | 3917122.73 | 0.00 | 0.00 | 0.368300E+09 | 0.00 | 0.35 |
| August | 96899.08 | 0.238549E+09 | 0.00 | 5074328.09 | 0.00 | 0.00 | 0.454485E+09 | 0.00 | 0.35 |
| September | 0.111525E+09 | 90493417.47 | 0.00 | 6402329.02 | 0.00 | 0.00 | 0.746109E+09 | 0.00 | 0.35 |
| October | 0.109524E+10 | 2024113.64 | 0.00 | 5375475.40 | 0.00 | 0.288745E+09 | 0.895790E+09 | 0.00 | 0.35 |
| November | 0.174153E+10 | 0.00 | 0.00 | 3365155.24 | 0.00 | 0.250152E+09 | 0.704703E+09 | 0.00 | 0.35 |
| December | 0.212786E+10 | 0.00 | 0.00 | 1305913.57 | 0.00 | 0.770376E+09 | 0.303999E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.129607E+11 | 0.942366E+09 | 0.00 | 42495055.07 | 0.00 | 0.253334E+10 | 0.687134E+10 | 0.00 | 0.35 |
| Minimum of Months | 96899.08 | 0.00 | 0.00 | 1146191.08 | 0.00 | 0.00 | 0.273065E+09 | 0.00 | 0.35 |
| Maximum of Months | 0.221753E+10 | 0.321820E+09 | 0.00 | 6402329.02 | 0.00 | 0.770376E+09 | 0.975970E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.221537E+10 | 0.00 | 0.00 | 2715242.71 | 0.00 | 0.160539E+09 | 0.699398E+09 | 0.00 | 0.35 |
| February | 0.178694E+10 | 0.00 | 0.00 | 1840860.12 | 0.00 | 0.573656E+09 | 0.486945E+09 | 0.00 | 0.35 |
| March | 0.167475E+10 | 0.00 | 0.00 | 2844643.77 | 0.00 | 0.277894E+09 | 0.507230E+09 | 0.00 | 0.35 |
| April | 0.173308E+10 | 0.00 | 0.00 | 1164886.69 | 0.00 | 0.212835E+09 | 0.275824E+09 | 0.00 | 0.35 |
| May | 0.461407E+09 | 15558797.01 | 0.00 | 4527095.57 | 0.00 | 0.00 | 0.978295E+09 | 0.00 | 0.35 |
| June | 1188126.99 | 0.273998E+09 | 0.00 | 4040791.83 | 0.00 | 0.00 | 0.462265E+09 | 0.00 | 0.35 |
| July | 436935.60 | 0.321996E+09 | 0.00 | 3924462.97 | 0.00 | 0.00 | 0.368227E+09 | 0.00 | 0.35 |
| August | 96936.88 | 0.238715E+09 | 0.00 | 5089421.89 | 0.00 | 0.00 | 0.454301E+09 | 0.00 | 0.35 |
| September | 0.110904E+09 | 90470146.37 | 0.00 | 6414080.20 | 0.00 | 0.00 | 0.746776E+09 | 0.00 | 0.35 |
| October | 0.109882E+10 | 2022584.63 | 0.00 | 5369402.58 | 0.00 | 0.286905E+09 | 0.894058E+09 | 0.00 | 0.35 |
| November | 0.174138E+10 | 0.00 | 0.00 | 3363277.16 | 0.00 | 0.250152E+09 | 0.704358E+09 | 0.00 | 0.35 |
| December | 0.212925E+10 | 0.00 | 0.00 | 1307481.98 | 0.00 | 0.770630E+09 | 0.302300E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.129536E+11 | 0.942761E+09 | 0.00 | 42601647.48 | 0.00 | 0.253261E+10 | 0.687998E+10 | 0.00 | 0.35 |
| Minimum of Months | 96936.88 | 0.00 | 0.00 | 1164886.69 | 0.00 | 0.00 | 0.275824E+09 | 0.00 | 0.35 |
| Maximum of Months | 0.221537E+10 | 0.321996E+09 | 0.00 | 6414080.20 | 0.00 | 0.770630E+09 | 0.978295E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.384309E+09 | 0.00 | 0.00 | 879436.45 | 0.00 | 0.915303E+09 | 0.150645E+09 | 0.00 | 0.35 |
| February | 0.313570E+09 | 0.00 | 0.00 | 856848.47 | 0.00 | 0.914699E+09 | 0.134806E+09 | 0.00 | 0.35 |
| March | 0.277716E+09 | 346.83 | 0.00 | 1572728.43 | 0.00 | 0.758826E+09 | 0.138297E+09 | 0.00 | 0.35 |
| April | 0.249618E+09 | 0.00 | 0.00 | 934582.90 | 0.00 | 0.702166E+09 | 96503255.87 | 0.00 | 0.35 |
| May | 0.368233E+09 | 8450151.30 | 0.00 | 1615869.04 | 0.00 | 0.112756E+09 | 0.162570E+09 | 0.00 | 0.35 |
| June | 0.106775E+09 | 0.143444E+09 | 0.00 | 1208726.72 | 14248.18 | 0.00 | 0.128422E+09 | 0.00 | 0.35 |
| July | 78370235.90 | 0.166136E+09 | 0.00 | 1226224.88 | 0.00 | 0.00 | 0.117123E+09 | 0.00 | 0.35 |
| August | 0.107250E+09 | 0.120762E+09 | 0.00 | 1657454.87 | 0.00 | 0.00 | 0.136646E+09 | 0.00 | 0.35 |
| September | 0.207636E+09 | 47656630.15 | 0.00 | 2114777.71 | 0.00 | 39760258.56 | 0.143684E+09 | 0.00 | 0.35 |
| October | 0.289061E+09 | 1194760.37 | 0.00 | 2182044.26 | 0.00 | 0.583373E+09 | 0.176887E+09 | 0.00 | 0.35 |
| November | 0.347466E+09 | 0.00 | 0.00 | 1267546.26 | 0.00 | 0.753612E+09 | 0.164647E+09 | 0.00 | 0.35 |
| December | 0.240571E+09 | 0.00 | 0.00 | 572957.43 | 0.00 | 0.122322E+10 | 79471030.40 | 0.00 | 0.35 |
| Annual Sum or Average | 0.297058E+10 | 0.487644E+09 | 0.00 | 16089197.44 | 14248.18 | 0.600372E+10 | 0.162970E+10 | 0.00 | 0.35 |
| Minimum of Months | 78370235.90 | 0.00 | 0.00 | 572957.43 | 0.00 | 0.00 | 79471030.40 | 0.00 | 0.35 |
| Maximum of Months | 0.384309E+09 | 0.166136E+09 | 0.00 | 2182044.26 | 14248.18 | 0.122322E+10 | 0.176887E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.133624E+09 | 0.00 | 0.00 | 4436.82 | 0.00 | 0.127023E+10 | 1631950.27 | 0.00 | 0.35 |
| February | 0.130987E+09 | 0.00 | 0.00 | 4900.06 | 0.00 | 0.119569E+10 | 2478941.40 | 0.00 | 0.35 |
| March | 0.206883E+09 | 0.00 | 0.00 | 333099.20 | 0.00 | 0.903178E+09 | 40587108.63 | 0.00 | 0.35 |
| April | 0.225817E+09 | 0.00 | 0.00 | 277658.91 | 0.00 | 0.764458E+09 | 43085789.64 | 0.00 | 0.35 |
| May | 0.387160E+09 | 7696576.40 | 0.00 | 1182998.25 | 0.00 | 0.121640E+09 | 0.130567E+09 | 0.00 | 0.35 |
| June | 0.102787E+09 | 0.139699E+09 | 0.00 | 1234287.40 | 14960.63 | 0.00 | 0.132748E+09 | 0.00 | 0.35 |
| July | 77693439.90 | 0.163458E+09 | 0.00 | 1213369.16 | 0.00 | 0.00 | 0.118997E+09 | 0.00 | 0.35 |
| August | 0.116046E+09 | 0.116940E+09 | 0.00 | 1328054.08 | 0.00 | 0.00 | 0.129284E+09 | 0.00 | 0.35 |
| September | 0.214300E+09 | 47649922.56 | 0.00 | 1188530.75 | 29993.94 | 58482050.26 | 0.108991E+09 | 0.00 | 0.35 |
| October | 0.265357E+09 | 1004242.80 | 0.00 | 349074.81 | 0.00 | 0.703631E+09 | 46073571.37 | 0.00 | 0.35 |
| November | 0.171746E+09 | 0.00 | 0.00 | 51591.47 | 0.00 | 0.103985E+10 | 9279854.58 | 0.00 | 0.35 |
| December | 62351058.22 | 0.00 | 0.00 | 1898.60 | 0.00 | 0.145173E+10 | 591263.12 | 0.00 | 0.35 |
| Annual Sum or Average | 0.209475E+10 | 0.476447E+09 | 0.00 | 7169899.53 | 44954.57 | 0.750889E+10 | 0.764316E+09 | 0.00 | 0.35 |
| Minimum of Months | 62351058.22 | 0.00 | 0.00 | 1898.60 | 0.00 | 0.00 | 591263.12 | 0.00 | 0.35 |
| Maximum of Months | 0.387160E+09 | 0.163458E+09 | 0.00 | 1328054.08 | 29993.94 | 0.145173E+10 | 0.132748E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.390996E+09 | 0.00 | 0.00 | 769557.88 | 0.00 | 0.909093E+09 | 0.150707E+09 | 0.00 | 0.35 |
| February | 0.319881E+09 | 0.00 | 0.00 | 740356.64 | 0.00 | 0.903256E+09 | 0.141805E+09 | 0.00 | 0.35 |
| March | 0.310096E+09 | 0.00 | 0.00 | 1395327.65 | 0.00 | 0.736037E+09 | 0.130980E+09 | 0.00 | 0.35 |
| April | 0.266321E+09 | 0.00 | 0.00 | 863898.33 | 0.00 | 0.684774E+09 | 0.101583E+09 | 0.00 | 0.35 |
| May | 0.372242E+09 | 8261690.73 | 0.00 | 1625393.88 | 0.00 | 0.106091E+09 | 0.171170E+09 | 0.00 | 0.35 |
| June | 98072971.46 | 0.144609E+09 | 0.00 | 1557992.39 | 19558.69 | 0.00 | 0.137740E+09 | 0.00 | 0.35 |
| July | 72727301.29 | 0.168175E+09 | 0.00 | 1436956.48 | 0.00 | 0.00 | 0.123891E+09 | 0.00 | 0.35 |
| August | 94764923.55 | 0.122710E+09 | 0.00 | 2065207.22 | 0.00 | 0.00 | 0.148531E+09 | 0.00 | 0.35 |
| September | 0.207222E+09 | 47191105.91 | 0.00 | 2228458.34 | 0.00 | 38021547.60 | 0.148235E+09 | 0.00 | 0.35 |
| October | 0.291213E+09 | 1166460.93 | 0.00 | 1951404.17 | 0.00 | 0.580151E+09 | 0.180965E+09 | 0.00 | 0.35 |
| November | 0.348657E+09 | 0.00 | 0.00 | 1131081.35 | 0.00 | 0.752314E+09 | 0.165694E+09 | 0.00 | 0.35 |
| December | 0.250264E+09 | 0.00 | 0.00 | 515863.62 | 0.00 | 0.121359E+10 | 80427780.94 | 0.00 | 0.35 |
| Annual Sum or Average | 0.302246E+10 | 0.492113E+09 | 0.00 | 16281497.94 | 19558.69 | 0.592332E+10 | 0.168173E+10 | 0.00 | 0.35 |
| Minimum of Months | 72727301.29 | 0.00 | 0.00 | 515863.62 | 0.00 | 0.00 | 80427780.94 | 0.00 | 0.35 |
| Maximum of Months | 0.390996E+09 | 0.168175E+09 | 0.00 | 2228458.34 | 19558.69 | 0.121359E+10 | 0.180965E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 96386507.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130685E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.135641E+09 | 0.00 | 0.00 | 1181.01 | 0.00 | 0.119191E+10 | 656008.07 | 0.00 | 0.35 |
| March | 0.229504E+09 | 0.00 | 0.00 | 188408.59 | 0.00 | 0.893277E+09 | 30695547.31 | 0.00 | 0.35 |
| April | 0.266959E+09 | 0.00 | 0.00 | 233533.68 | 0.00 | 0.733318E+09 | 36006925.36 | 0.00 | 0.35 |
| May | 0.380619E+09 | 7530768.20 | 0.00 | 1183786.62 | 0.00 | 0.119394E+09 | 0.146496E+09 | 0.00 | 0.35 |
| June | 93492962.83 | 0.141080E+09 | 0.00 | 1639168.47 | 20464.53 | 0.00 | 0.141683E+09 | 0.00 | 0.35 |
| July | 72861328.57 | 0.165766E+09 | 0.00 | 1440360.50 | 0.00 | 0.00 | 0.124559E+09 | 0.00 | 0.35 |
| August | 0.101892E+09 | 0.119297E+09 | 0.00 | 1730432.87 | 0.00 | 0.00 | 0.142713E+09 | 0.00 | 0.35 |
| September | 0.218423E+09 | 47173903.70 | 0.00 | 1230399.57 | 0.00 | 54224508.73 | 0.113016E+09 | 0.00 | 0.35 |
| October | 0.293239E+09 | 984067.90 | 0.00 | 158957.27 | 0.00 | 0.692371E+09 | 29986661.85 | 0.00 | 0.35 |
| November | 0.164614E+09 | 0.00 | 0.00 | 18243.49 | 0.00 | 0.105049E+10 | 4422125.46 | 0.00 | 0.35 |
| December | 51394802.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146110E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.210503E+10 | 0.481831E+09 | 0.00 | 7824472.07 | 20464.53 | 0.750293E+10 | 0.770236E+09 | 0.00 | 0.35 |
| Minimum of Months | 51394802.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.380619E+09 | 0.165766E+09 | 0.00 | 1730432.87 | 20464.53 | 0.146110E+10 | 0.146496E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.155566E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125312E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.169661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116378E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.298361E+09 | 0.00 | 0.00 | 99863.08 | 0.00 | 0.838992E+09 | 19691278.02 | 0.00 | 0.35 |
| April | 0.341969E+09 | 0.00 | 0.00 | 115694.81 | 0.00 | 0.673526E+09 | 25661072.14 | 0.00 | 0.35 |
| May | 0.439700E+09 | 7189441.53 | 0.00 | 909262.90 | 0.00 | 65495070.98 | 0.158365E+09 | 0.00 | 0.35 |
| June | 65184318.96 | 0.134869E+09 | 0.00 | 1322520.09 | 0.00 | 0.00 | 0.176969E+09 | 0.00 | 0.35 |
| July | 49242343.29 | 0.159207E+09 | 0.00 | 1280572.56 | 0.00 | 0.00 | 0.150187E+09 | 0.00 | 0.35 |
| August | 77254890.69 | 0.113870E+09 | 0.00 | 1350174.14 | 0.00 | 0.00 | 0.173329E+09 | 0.00 | 0.35 |
| September | 0.225619E+09 | 45630947.49 | 0.00 | 1015100.55 | 0.00 | 34764642.79 | 0.137635E+09 | 0.00 | 0.35 |
| October | 0.389879E+09 | 917930.55 | 0.00 | 96992.69 | 0.00 | 0.607809E+09 | 24455283.17 | 0.00 | 0.35 |
| November | 0.250474E+09 | 0.00 | 0.00 | 3965.80 | 0.00 | 0.972417E+09 | 1933842.76 | 0.00 | 0.35 |
| December | 77839218.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144285E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.254075E+10 | 0.461684E+09 | 0.00 | 6194146.63 | 0.00 | 0.705276E+10 | 0.868226E+09 | 0.00 | 0.35 |
| Minimum of Months | 49242343.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.439700E+09 | 0.159207E+09 | 0.00 | 1350174.14 | 0.00 | 0.144285E+10 | 0.176969E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.153973E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125463E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.169116E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116440E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.298355E+09 | 0.00 | 0.00 | 101801.41 | 0.00 | 0.839189E+09 | 19912256.72 | 0.00 | 0.35 |
| April | 0.342172E+09 | 0.00 | 0.00 | 121059.14 | 0.00 | 0.672820E+09 | 26576812.40 | 0.00 | 0.35 |
| May | 0.439264E+09 | 7181761.04 | 0.00 | 922011.68 | 0.00 | 65717826.38 | 0.159000E+09 | 0.00 | 0.35 |
| June | 65293392.08 | 0.134959E+09 | 0.00 | 1331225.16 | 0.00 | 0.00 | 0.176872E+09 | 0.00 | 0.35 |
| July | 49067651.46 | 0.159336E+09 | 0.00 | 1285520.38 | 0.00 | 0.00 | 0.150368E+09 | 0.00 | 0.35 |
| August | 77026876.26 | 0.113989E+09 | 0.00 | 1361064.68 | 0.00 | 0.00 | 0.173551E+09 | 0.00 | 0.35 |
| September | 0.224959E+09 | 45603845.22 | 0.00 | 1020696.74 | 0.00 | 35076382.39 | 0.138145E+09 | 0.00 | 0.35 |
| October | 0.390069E+09 | 916306.04 | 0.00 | 96915.06 | 0.00 | 0.608041E+09 | 24118174.78 | 0.00 | 0.35 |
| November | 0.249379E+09 | 0.00 | 0.00 | 4467.14 | 0.00 | 0.973425E+09 | 2062163.78 | 0.00 | 0.35 |
| December | 77214867.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144336E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.253589E+10 | 0.461986E+09 | 0.00 | 6244761.39 | 0.00 | 0.705666E+10 | 0.870606E+09 | 0.00 | 0.35 |
| Minimum of Months | 49067651.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.439264E+09 | 0.159336E+09 | 0.00 | 1361064.68 | 0.00 | 0.144336E+10 | 0.176872E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.541013E+09 | 0.00 | 0.00 | 949440.21 | 0.00 | 0.738323E+09 | 0.188548E+09 | 0.00 | 0.35 |
| February | 0.442322E+09 | 0.00 | 0.00 | 819267.37 | 0.00 | 0.774620E+09 | 0.161933E+09 | 0.00 | 0.35 |
| March | 0.396519E+09 | 0.00 | 0.00 | 1277220.30 | 0.00 | 0.650943E+09 | 0.144621E+09 | 0.00 | 0.35 |
| April | 0.373593E+09 | 0.00 | 0.00 | 700603.52 | 0.00 | 0.587642E+09 | 0.103617E+09 | 0.00 | 0.35 |
| May | 0.421592E+09 | 8042906.64 | 0.00 | 1357643.51 | 0.00 | 55027015.06 | 0.191919E+09 | 0.00 | 0.35 |
| June | 75976639.71 | 0.139262E+09 | 0.00 | 1266089.64 | 0.00 | 0.00 | 0.166192E+09 | 0.00 | 0.35 |
| July | 51069194.39 | 0.162363E+09 | 0.00 | 1294492.11 | 0.00 | 0.00 | 0.147026E+09 | 0.00 | 0.35 |
| August | 64260532.95 | 0.118414E+09 | 0.00 | 1704946.90 | 0.00 | 0.00 | 0.183695E+09 | 0.00 | 0.35 |
| September | 0.198209E+09 | 45703414.74 | 0.00 | 2023731.26 | 0.00 | 24144474.52 | 0.185721E+09 | 0.00 | 0.35 |
| October | 0.430633E+09 | 1115959.37 | 0.00 | 1920629.56 | 0.00 | 0.435570E+09 | 0.204016E+09 | 0.00 | 0.35 |
| November | 0.498218E+09 | 0.00 | 0.00 | 1272225.46 | 0.00 | 0.587163E+09 | 0.199133E+09 | 0.00 | 0.35 |
| December | 0.431883E+09 | 0.00 | 0.00 | 630243.85 | 0.00 | 0.102586E+10 | 0.102646E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.392529E+10 | 0.474901E+09 | 0.00 | 15216533.69 | 0.00 | 0.487929E+10 | 0.197907E+10 | 0.00 | 0.35 |
| Minimum of Months | 51069194.39 | 0.00 | 0.00 | 630243.85 | 0.00 | 0.00 | 0.102646E+09 | 0.00 | 0.35 |
| Maximum of Months | 0.541013E+09 | 0.162363E+09 | 0.00 | 2023731.26 | 0.00 | 0.102586E+10 | 0.204016E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.539083E+09 | 0.00 | 0.00 | 951822.24 | 0.00 | 0.741099E+09 | 0.187599E+09 | 0.00 | 0.35 |
| February | 0.441584E+09 | 0.00 | 0.00 | 824433.74 | 0.00 | 0.775668E+09 | 0.161634E+09 | 0.00 | 0.35 |
| March | 0.398361E+09 | 0.00 | 0.00 | 1280921.41 | 0.00 | 0.649749E+09 | 0.144043E+09 | 0.00 | 0.35 |
| April | 0.372780E+09 | 0.00 | 0.00 | 712343.57 | 0.00 | 0.587524E+09 | 0.104840E+09 | 0.00 | 0.35 |
| May | 0.420043E+09 | 8033266.57 | 0.00 | 1370590.51 | 0.00 | 55024049.17 | 0.193685E+09 | 0.00 | 0.35 |
| June | 75888397.97 | 0.139344E+09 | 0.00 | 1276184.23 | 0.00 | 0.00 | 0.166327E+09 | 0.00 | 0.35 |
| July | 50769232.40 | 0.162470E+09 | 0.00 | 1300012.71 | 0.00 | 0.00 | 0.147354E+09 | 0.00 | 0.35 |
| August | 63921928.49 | 0.118509E+09 | 0.00 | 1716239.28 | 0.00 | 0.00 | 0.184044E+09 | 0.00 | 0.35 |
| September | 0.198567E+09 | 45679816.45 | 0.00 | 2031089.79 | 0.00 | 24144592.51 | 0.185374E+09 | 0.00 | 0.35 |
| October | 0.429907E+09 | 1114032.22 | 0.00 | 1923789.81 | 0.00 | 0.435850E+09 | 0.204410E+09 | 0.00 | 0.35 |
| November | 0.495697E+09 | 0.00 | 0.00 | 1275317.39 | 0.00 | 0.588735E+09 | 0.199958E+09 | 0.00 | 0.35 |
| December | 0.431708E+09 | 0.00 | 0.00 | 632611.79 | 0.00 | 0.102645E+10 | 0.102245E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.391831E+10 | 0.475150E+09 | 0.00 | 15295356.47 | 0.00 | 0.488425E+10 | 0.198151E+10 | 0.00 | 0.35 |
| Minimum of Months | 50769232.40 | 0.00 | 0.00 | 632611.79 | 0.00 | 0.00 | 0.102245E+09 | 0.00 | 0.35 |
| Maximum of Months | 0.539083E+09 | 0.162470E+09 | 0.00 | 2031089.79 | 0.00 | 0.102645E+10 | 0.204410E+09 | 0.00 | 0.35 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:28
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.146298E+12 | 0.110531E+11 | 0.00 | 0.201221E+10 | 0.155387E+11 |
| February | 0.172824E+12 | 0.146843E+11 | 0.00 | 0.185990E+10 | 0.163614E+11 |
| March | 0.199354E+12 | 0.162391E+11 | 0.00 | 0.165860E+10 | 0.193315E+11 |
| April | 0.199340E+12 | 0.161007E+11 | 0.00 | 0.147463E+10 | 0.110283E+11 |
| May | 0.227673E+12 | 0.109422E+11 | 0.00 | 0.106410E+10 | 0.296390E+11 |
| June | 0.233096E+12 | 0.380970E+10 | 0.00 | 0.431040E+09 | 0.112064E+12 |
| July | 0.220967E+12 | 0.315241E+10 | 0.00 | 0.399908E+09 | 0.120625E+12 |
| August | 0.220972E+12 | 0.462064E+10 | 0.00 | 0.523397E+09 | 0.114205E+12 |
| September | 0.172488E+12 | 0.785606E+10 | 0.00 | 0.826003E+09 | 0.807798E+11 |
| October | 0.160144E+12 | 0.131581E+11 | 0.00 | 0.174701E+10 | 0.265323E+11 |
| November | 0.149772E+12 | 0.119375E+11 | 0.00 | 0.189655E+10 | 0.164864E+11 |
| December | 0.126031E+12 | 0.197485E+11 | 0.00 | 0.215392E+10 | 0.195484E+11 |
| Annual Sum or Average | 0.222896E+13 | 0.133302E+12 | 0.00 | 0.160473E+11 | 0.582140E+12 |
| Minimum of Months | 0.126031E+12 | 0.315241E+10 | 0.00 | 0.399908E+09 | 0.110283E+11 |
| Maximum of Months | 0.233096E+12 | 0.197485E+11 | 0.00 | 0.215392E+10 | 0.120625E+12 |