Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000
Simulation Timestamp: 2023-10-16 09:14:34
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1695.24 | 540.81 | 600.30 |
| Net Site Energy | 1695.24 | 540.81 | 600.30 |
| Total Source Energy | 5368.83 | 1712.75 | 1901.16 |
| Net Source Energy | 5368.83 | 1712.75 | 1901.16 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 568.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 186.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 331.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1695.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 568.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 50.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 186.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 331.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 568.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 50.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 186.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 331.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 385.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 600.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 346.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 540.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1695.240 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1695.240 | 100.00 |
| Total On-Site and Utility Electric Sources | 1695.240 | 100.00 |
| Total Electricity End Uses | 1695.240 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 30.45 |
| Air to Air Heat Recovery for Heating | 0.00 | 69.55 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 11.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8760.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
| Latitude [deg] | 10.82 |
| Longitude [deg] | 106.67 |
| Elevation [m] | 5.00 |
| Time Zone | 7.00 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 06-MAY-16:19 | - | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 34603.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 4289.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22609.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 9363.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 36279.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 107146.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 34603.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4034.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 254.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18441.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 9363.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 36279.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 1801.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 590.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1051.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 5368.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 638.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 56.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 209.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 372.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1901.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 574.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 188.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 335.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1712.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.339602 |
| SPLIT GNW SUPPLY FAN | 0.341521 |
| SPLIT OFFICE SUPPLY FAN | 0.387547 |
| SPLIT GNE SUPPLY FAN | 0.325116 |
| SPLIT GN1 SUPPLY FAN | 0.292868 |
| SPLIT GN2 SUPPLY FAN | 0.292509 |
| SPLIT GS1 SUPPLY FAN | 0.291169 |
| SPLIT GS2 SUPPLY FAN | 0.293425 |
| SPLIT MSW SUPPLY FAN | 0.756964 |
| SPLIT MNW SUPPLY FAN | 0.760913 |
| SPLIT MSE SUPPLY FAN | 0.715725 |
| SPLIT MNE SUPPLY FAN | 0.719670 |
| SPLIT MN1 SUPPLY FAN | 0.647723 |
| SPLIT MN2 SUPPLY FAN | 0.646845 |
| SPLIT MS1 SUPPLY FAN | 0.643972 |
| SPLIT MS2 SUPPLY FAN | 0.643093 |
| SPLIT TSW SUPPLY FAN | 0.413182 |
| SPLIT TNW SUPPLY FAN | 0.417877 |
| SPLIT TSE SUPPLY FAN | 0.381821 |
| SPLIT TNE SUPPLY FAN | 0.386501 |
| SPLIT TN1 SUPPLY FAN | 0.357937 |
| SPLIT TN2 SUPPLY FAN | 0.356746 |
| SPLIT TS1 SUPPLY FAN | 0.353229 |
| SPLIT TS2 SUPPLY FAN | 0.352037 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.339602 |
| G NW APARTMENT DIRECT AIR | 0.341521 |
| OFFICE DIRECT AIR | 0.387547 |
| G NE APARTMENT DIRECT AIR | 0.325116 |
| G N1 APARTMENT DIRECT AIR | 0.292868 |
| G N2 APARTMENT DIRECT AIR | 0.292509 |
| G S1 APARTMENT DIRECT AIR | 0.291169 |
| G S2 APARTMENT DIRECT AIR | 0.293425 |
| M SW APARTMENT DIRECT AIR | 0.756964 |
| M NW APARTMENT DIRECT AIR | 0.760913 |
| M SE APARTMENT DIRECT AIR | 0.715725 |
| M NE APARTMENT DIRECT AIR | 0.719670 |
| M N1 APARTMENT DIRECT AIR | 0.647723 |
| M N2 APARTMENT DIRECT AIR | 0.646845 |
| M S1 APARTMENT DIRECT AIR | 0.643972 |
| M S2 APARTMENT DIRECT AIR | 0.643093 |
| T SW APARTMENT DIRECT AIR | 0.413182 |
| T NW APARTMENT DIRECT AIR | 0.417877 |
| T SE APARTMENT DIRECT AIR | 0.381821 |
| T NE APARTMENT DIRECT AIR | 0.386501 |
| T N1 APARTMENT DIRECT AIR | 0.357937 |
| T N2 APARTMENT DIRECT AIR | 0.356746 |
| T S1 APARTMENT DIRECT AIR | 0.353229 |
| T S2 APARTMENT DIRECT AIR | 0.352037 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.339602 | 0.339602 | 0.339602 | 0.339602 | 0.339602 | 0.339602 | 1.00 | 1.00 | 0.339602 |
| SPLIT GNW | 0.341521 | 0.341521 | 0.341521 | 0.341521 | 0.341521 | 0.341521 | 1.00 | 1.00 | 0.341521 |
| SPLIT OFFICE | 0.387547 | 0.387547 | 0.387547 | 0.387547 | 0.387547 | 0.387547 | 1.00 | 1.00 | 0.387547 |
| SPLIT GNE | 0.325116 | 0.325116 | 0.325116 | 0.325116 | 0.325116 | 0.325116 | 1.00 | 1.00 | 0.325116 |
| SPLIT GN1 | 0.292868 | 0.292868 | 0.292868 | 0.292868 | 0.292868 | 0.292868 | 1.00 | 1.00 | 0.292868 |
| SPLIT GN2 | 0.292509 | 0.292509 | 0.292509 | 0.292509 | 0.292509 | 0.292509 | 1.00 | 1.00 | 0.292509 |
| SPLIT GS1 | 0.291169 | 0.291169 | 0.291169 | 0.291169 | 0.291169 | 0.291169 | 1.00 | 1.00 | 0.291169 |
| SPLIT GS2 | 0.293425 | 0.293425 | 0.293425 | 0.293425 | 0.293425 | 0.293425 | 1.00 | 1.000000 | 0.293425 |
| SPLIT MSW | 0.756964 | 0.756964 | 0.756964 | 0.756964 | 0.756964 | 0.756964 | 1.00 | 1.00 | 0.756964 |
| SPLIT MNW | 0.760913 | 0.760913 | 0.760913 | 0.760913 | 0.760913 | 0.760913 | 1.00 | 1.000000 | 0.760913 |
| SPLIT MSE | 0.715725 | 0.715725 | 0.715725 | 0.715725 | 0.715725 | 0.715725 | 1.00 | 1.00 | 0.715725 |
| SPLIT MNE | 0.719670 | 0.719670 | 0.719670 | 0.719670 | 0.719670 | 0.719670 | 1.00 | 1.00 | 0.719670 |
| SPLIT MN1 | 0.647723 | 0.647723 | 0.647723 | 0.647723 | 0.647723 | 0.647723 | 1.00 | 1.00 | 0.647723 |
| SPLIT MN2 | 0.646845 | 0.646845 | 0.646845 | 0.646845 | 0.646845 | 0.646845 | 1.00 | 1.00 | 0.646845 |
| SPLIT MS1 | 0.643972 | 0.643972 | 0.643972 | 0.643972 | 0.643972 | 0.643972 | 1.00 | 1.00 | 0.643972 |
| SPLIT MS2 | 0.643093 | 0.643093 | 0.643093 | 0.643093 | 0.643093 | 0.643093 | 1.00 | 1.00 | 0.643093 |
| SPLIT TSW | 0.413182 | 0.413182 | 0.413182 | 0.413182 | 0.413182 | 0.413182 | 1.00 | 1.00 | 0.413182 |
| SPLIT TNW | 0.417877 | 0.417877 | 0.417877 | 0.417877 | 0.417877 | 0.417877 | 1.00 | 1.00 | 0.417877 |
| SPLIT TSE | 0.381821 | 0.381821 | 0.381821 | 0.381821 | 0.381821 | 0.381821 | 1.00 | 1.00 | 0.381821 |
| SPLIT TNE | 0.386501 | 0.386501 | 0.386501 | 0.386501 | 0.386501 | 0.386501 | 1.00 | 1.00 | 0.386501 |
| SPLIT TN1 | 0.357937 | 0.357937 | 0.357937 | 0.357937 | 0.357937 | 0.357937 | 1.00 | 1.00 | 0.357937 |
| SPLIT TN2 | 0.356746 | 0.356746 | 0.356746 | 0.356746 | 0.356746 | 0.356746 | 1.00 | 1.00 | 0.356746 |
| SPLIT TS1 | 0.353229 | 0.353229 | 0.353229 | 0.353229 | 0.353229 | 0.353229 | 1.00 | 1.000000 | 0.353229 |
| SPLIT TS2 | 0.352037 | 0.352037 | 0.352037 | 0.352037 | 0.352037 | 0.352037 | 1.00 | 1.000000 | 0.352037 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.339602 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.341521 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.387547 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.325116 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.292868 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.292509 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.291169 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.293425 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.756964 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.760913 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.715725 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.719670 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.647723 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.646845 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.643972 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.643093 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.413182 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.417877 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.381821 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.386501 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.357937 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.356746 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.353229 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.352037 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.339602 | 0.339602 | 0.339602 | 0.339602 | 6587.71 | 7794.16 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.341521 | 0.341521 | 0.341521 | 0.341521 | 6588.23 | 7838.03 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.387547 | 0.387547 | 0.387547 | 0.387547 | 7393.40 | 8904.81 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.325116 | 0.325116 | 0.325116 | 0.325116 | 6350.73 | 7463.05 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.292868 | 0.292868 | 0.292868 | 0.292868 | 5721.17 | 6725.89 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.292509 | 0.292509 | 0.292509 | 0.292509 | 5715.94 | 6717.70 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.291169 | 0.291169 | 0.291169 | 0.291169 | 5742.80 | 6687.08 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.293425 | 0.293425 | 0.293425 | 0.293425 | 5778.35 | 6738.64 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.756964 | 0.756964 | 0.756964 | 0.756964 | 14669.54 | 17365.81 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.760913 | 0.760913 | 0.760913 | 0.760913 | 14683.12 | 17456.09 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.715725 | 0.715725 | 0.715725 | 0.715725 | 14077.78 | 16423.16 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.719670 | 0.719670 | 0.719670 | 0.719670 | 14082.39 | 16513.33 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.647723 | 0.647723 | 0.647723 | 0.647723 | 12611.88 | 14868.73 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.646845 | 0.646845 | 0.646845 | 0.646845 | 12599.06 | 14848.67 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.643972 | 0.643972 | 0.643972 | 0.643972 | 12635.70 | 14783.00 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.643093 | 0.643093 | 0.643093 | 0.643093 | 12623.13 | 14762.90 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.413182 | 0.413182 | 0.413182 | 0.413182 | 7998.24 | 9476.10 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.417877 | 0.417877 | 0.417877 | 0.417877 | 8054.78 | 9583.42 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.381821 | 0.381821 | 0.381821 | 0.381821 | 7519.80 | 8759.24 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.386501 | 0.386501 | 0.386501 | 0.386501 | 7573.44 | 8866.21 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.357937 | 0.357937 | 0.357937 | 0.357937 | 6882.68 | 8213.27 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.356746 | 0.356746 | 0.356746 | 0.356746 | 6864.56 | 8186.05 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.353229 | 0.353229 | 0.353229 | 0.353229 | 6833.73 | 8105.67 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.352037 | 0.352037 | 0.352037 | 0.352037 | 6815.74 | 8078.42 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.339602 | 6587.71 | 0.788738 |
| SPLIT GNW COOLING COIL | 0.341521 | 6588.23 | 0.790486 |
| SPLIT OFFICE COOLING COIL | 0.387547 | 7393.40 | 0.795015 |
| SPLIT GNE COOLING COIL | 0.325116 | 6350.73 | 0.785564 |
| SPLIT GN1 COOLING COIL | 0.292868 | 5721.17 | 0.785543 |
| SPLIT GN2 COOLING COIL | 0.292509 | 5715.94 | 0.785447 |
| SPLIT GS1 COOLING COIL | 0.291169 | 5742.80 | 0.781570 |
| SPLIT GS2 COOLING COIL | 0.293425 | 5778.35 | 0.782048 |
| SPLIT MSW COOLING COIL | 0.756964 | 14669.54 | 0.789044 |
| SPLIT MNW COOLING COIL | 0.760913 | 14683.12 | 0.790391 |
| SPLIT MSE COOLING COIL | 0.715725 | 14077.78 | 0.782417 |
| SPLIT MNE COOLING COIL | 0.719670 | 14082.39 | 0.785020 |
| SPLIT MN1 COOLING COIL | 0.647723 | 12611.88 | 0.786566 |
| SPLIT MN2 COOLING COIL | 0.646845 | 12599.06 | 0.786460 |
| SPLIT MS1 COOLING COIL | 0.643972 | 12635.70 | 0.784170 |
| SPLIT MS2 COOLING COIL | 0.643093 | 12623.13 | 0.784055 |
| SPLIT TSW COOLING COIL | 0.413182 | 7998.24 | 0.789397 |
| SPLIT TNW COOLING COIL | 0.417877 | 8054.78 | 0.790738 |
| SPLIT TSE COOLING COIL | 0.381821 | 7519.80 | 0.782020 |
| SPLIT TNE COOLING COIL | 0.386501 | 7573.44 | 0.784591 |
| SPLIT TN1 COOLING COIL | 0.357937 | 6882.68 | 0.792505 |
| SPLIT TN2 COOLING COIL | 0.356746 | 6864.56 | 0.792285 |
| SPLIT TS1 COOLING COIL | 0.353229 | 6833.73 | 0.789580 |
| SPLIT TS2 COOLING COIL | 0.352037 | 6815.74 | 0.789346 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 7794.16 |
| SPLIT GNW HEATING COIL | 7838.03 |
| SPLIT OFFICE HEATING COIL | 8904.81 |
| SPLIT GNE HEATING COIL | 7463.05 |
| SPLIT GN1 HEATING COIL | 6725.89 |
| SPLIT GN2 HEATING COIL | 6717.70 |
| SPLIT GS1 HEATING COIL | 6687.08 |
| SPLIT GS2 HEATING COIL | 6738.64 |
| SPLIT MSW HEATING COIL | 17365.81 |
| SPLIT MNW HEATING COIL | 17456.09 |
| SPLIT MSE HEATING COIL | 16423.16 |
| SPLIT MNE HEATING COIL | 16513.33 |
| SPLIT MN1 HEATING COIL | 14868.73 |
| SPLIT MN2 HEATING COIL | 14848.67 |
| SPLIT MS1 HEATING COIL | 14783.00 |
| SPLIT MS2 HEATING COIL | 14762.90 |
| SPLIT TSW HEATING COIL | 9476.10 |
| SPLIT TNW HEATING COIL | 9583.42 |
| SPLIT TSE HEATING COIL | 8759.24 |
| SPLIT TNE HEATING COIL | 8866.21 |
| SPLIT TN1 HEATING COIL | 8213.27 |
| SPLIT TN2 HEATING COIL | 8186.05 |
| SPLIT TS1 HEATING COIL | 8105.67 |
| SPLIT TS2 HEATING COIL | 8078.42 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 26.90 | 26.70 | 26.00 | 26.40 | 27.50 | 28.30 | 29.20 | 29.00 | 28.90 | 27.20 | 27.50 | 27.60 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 | 10.82 | 106.67 | 7.00 | 5.00 | 101265 | 1.2036 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 27.60 | 3.20 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.192E-004 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 4008.98962 | 4810.78754 | 0.28300 | 0.33960 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 3 | G NW APARTMENT | Cooling | 4031.03819 | 4837.24583 | 0.28460 | 0.34152 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 5 | OFFICE | Cooling | 4505.67374 | 5406.80849 | 0.32296 | 0.38755 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:00:00 | 30.52500 | 1.71492E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 0.00000 | 0.00000 | 0.00000 | 3.81060E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 | |
| 7 | G NE APARTMENT | Cooling | 3841.81980 | 4610.18376 | 0.27093 | 0.32512 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 9 | G N1 APARTMENT | Cooling | 3469.26422 | 4163.11706 | 0.24406 | 0.29287 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 11 | G N2 APARTMENT | Cooling | 3465.13210 | 4158.15852 | 0.24376 | 0.29251 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 13 | G S1 APARTMENT | Cooling | 3449.63140 | 4139.55768 | 0.24264 | 0.29117 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 15 | G S2 APARTMENT | Cooling | 3475.51526 | 4170.61831 | 0.24452 | 0.29343 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 17 | M SW APARTMENT | Cooling | 8910.70976 | 10692.85171 | 0.63080 | 0.75696 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 19 | M NW APARTMENT | Cooling | 8956.25521 | 10747.50626 | 0.63409 | 0.76091 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 21 | M SE APARTMENT | Cooling | 8436.50110 | 10123.80132 | 0.59644 | 0.71573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 23 | M NE APARTMENT | Cooling | 8481.91283 | 10178.29539 | 0.59972 | 0.71967 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 25 | M N1 APARTMENT | Cooling | 7655.62138 | 9186.74565 | 0.53977 | 0.64772 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 27 | M N2 APARTMENT | Cooling | 7645.41515 | 9174.49818 | 0.53904 | 0.64685 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 29 | M S1 APARTMENT | Cooling | 7612.03919 | 9134.44702 | 0.53664 | 0.64397 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 31 | M S2 APARTMENT | Cooling | 7601.81370 | 9122.17644 | 0.53591 | 0.64309 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 33 | T SW APARTMENT | Cooling | 4858.43858 | 5830.12630 | 0.34432 | 0.41318 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 35 | T NW APARTMENT | Cooling | 4912.78436 | 5895.34123 | 0.34823 | 0.41788 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 37 | T SE APARTMENT | Cooling | 4495.88709 | 5395.06451 | 0.31818 | 0.38182 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 39 | T NE APARTMENT | Cooling | 4549.92151 | 5459.90581 | 0.32208 | 0.38650 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 41 | T N1 APARTMENT | Cooling | 4220.95690 | 5065.14828 | 0.29828 | 0.35794 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 43 | T N2 APARTMENT | Cooling | 4207.23637 | 5048.68365 | 0.29729 | 0.35675 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 45 | T S1 APARTMENT | Cooling | 4166.71823 | 5000.06188 | 0.29436 | 0.35323 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 47 | T S2 APARTMENT | Cooling | 4152.98739 | 4983.58487 | 0.29336 | 0.35204 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4862.99 | 0.33960 | 0.33960 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4889.26 | 0.34152 | 0.34152 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5531.69 | 0.38755 | 0.38755 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 917.13 | 3.81060E-002 | 3.81060E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 4664.75 | 0.32512 | 0.32512 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 4223.33 | 0.29287 | 0.29287 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 4218.42 | 0.29251 | 0.29251 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 4200.00 | 0.29117 | 0.29117 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 4230.71 | 0.29343 | 0.29343 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 10788.05 | 0.75696 | 0.75696 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 10842.14 | 0.76091 | 0.76091 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 10224.45 | 0.71573 | 0.71573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 10278.46 | 0.71967 | 0.71967 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 9296.01 | 0.64772 | 0.64772 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 9283.96 | 0.64685 | 0.64685 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9244.45 | 0.64397 | 0.64397 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9232.37 | 0.64309 | 0.64309 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 5870.62 | 0.41318 | 0.41318 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 5934.90 | 0.41788 | 0.41788 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 5441.51 | 0.38182 | 0.38182 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 5505.53 | 0.38650 | 0.38650 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 5115.50 | 0.35794 | 0.35794 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 5099.22 | 0.35675 | 0.35675 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5051.14 | 0.35323 | 0.35323 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5034.84 | 0.35204 | 0.35204 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33960 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34152 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38755 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.32512 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29287 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29251 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29117 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29343 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.75696 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.76091 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.71573 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.71967 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64772 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64685 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64397 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64309 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.41318 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.41788 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38182 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38650 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35794 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35675 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35323 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35204 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33960 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33960 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33960 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33960 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33960 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.33960 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34152 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34152 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34152 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34152 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34152 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.34152 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38755 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38755 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38755 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38755 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38755 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.38755 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.32512 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.32512 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.32512 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.32512 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.32512 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.32512 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29287 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29287 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29287 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29287 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29287 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29287 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29251 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29251 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29251 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29251 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29251 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29251 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29117 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29117 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29117 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29117 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29117 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29117 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29343 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29343 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29343 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29343 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29343 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29343 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.75696 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.75696 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.75696 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.75696 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.75696 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.75696 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.76091 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.76091 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.76091 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.76091 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.76091 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.76091 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.71573 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.71573 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.71573 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.71573 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.71573 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.71573 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.71967 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.71967 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.71967 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.71967 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.71967 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.71967 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64772 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64772 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64772 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64772 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64772 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.64772 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64685 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64685 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64685 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64685 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64685 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.64685 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64397 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64397 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64397 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64397 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64397 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.64397 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64309 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64309 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64309 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64309 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64309 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.64309 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.41318 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.41318 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.41318 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.41318 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.41318 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.41318 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.41788 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.41788 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.41788 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.41788 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.41788 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.41788 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38182 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38182 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38182 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38182 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38182 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.38182 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38650 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38650 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38650 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38650 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38650 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.38650 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35794 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35794 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35794 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35794 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35794 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35794 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35675 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35675 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35675 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35675 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35675 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35675 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35323 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35323 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35323 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35323 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35323 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35323 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35204 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35204 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35204 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35204 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35204 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35204 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.33960 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.34152 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.38755 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.32512 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.29287 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.29251 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.29117 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.29343 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.75696 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.76091 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.71573 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.71967 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.64772 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.64685 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.64397 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.64309 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.41318 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.41788 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.38182 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.38650 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.35794 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.35675 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.35323 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.35204 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33960 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33960 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33960 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33960 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33960 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6587.71370 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7794.16162 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33960 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33960 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6587.71370 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78874 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 7794.16162 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34152 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34152 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34152 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34152 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34152 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6588.23034 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7838.03391 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34152 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34152 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6588.23034 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79049 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 7838.03391 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38755 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38755 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38755 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38755 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38755 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7393.40332 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8904.80896 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38755 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38755 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7393.40332 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79502 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 8904.80896 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.32512 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.32512 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.32512 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.32512 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.32512 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6350.73170 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7463.05393 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.32512 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32512 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6350.73170 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78556 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 7463.05393 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29287 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29287 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29287 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29287 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29287 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5721.17332 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6725.89333 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29287 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29287 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5721.17332 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78554 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 6725.89333 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29251 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29251 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29251 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29251 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29251 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5715.94205 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6717.70445 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29251 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29251 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5715.94205 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78545 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 6717.70445 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29117 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29117 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29117 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29117 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29117 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5742.79956 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6687.07819 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29117 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29117 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5742.79956 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78157 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 6687.07819 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29343 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29343 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29343 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29343 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29343 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5778.35148 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6738.64157 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29343 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29343 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5778.35148 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78205 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 6738.64157 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.75696 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.75696 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.75696 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.75696 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.75696 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14669.54004 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17365.81466 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.75696 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.75696 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14669.54004 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78904 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 17365.81466 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.76091 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.76091 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.76091 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.76091 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.76091 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14683.11675 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17456.09357 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.76091 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.76091 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14683.11675 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79039 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 17456.09357 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.71573 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.71573 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.71573 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.71573 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.71573 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14077.77780 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16423.16149 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.71573 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.71573 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14077.77780 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78242 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 16423.16149 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.71967 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.71967 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.71967 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.71967 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.71967 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14082.38762 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16513.33335 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.71967 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.71967 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14082.38762 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78502 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 16513.33335 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64772 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64772 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64772 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64772 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64772 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12611.88434 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 14868.73282 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64772 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64772 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12611.88434 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78657 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 14868.73282 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64685 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64685 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64685 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64685 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64685 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12599.05740 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 14848.67409 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64685 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64685 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12599.05740 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78646 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 14848.67409 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64397 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64397 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64397 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64397 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64397 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12635.70481 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 14783.00016 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64397 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64397 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12635.70481 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78417 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 14783.00016 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64309 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64309 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64309 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64309 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64309 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12623.13338 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 14762.89647 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64309 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64309 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12623.13338 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78405 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 14762.89647 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.41318 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.41318 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.41318 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.41318 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.41318 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7998.23786 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9476.09668 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.41318 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.41318 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7998.23786 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78940 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 9476.09668 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.41788 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.41788 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.41788 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.41788 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.41788 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8054.77572 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9583.41574 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.41788 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.41788 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8054.77572 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79074 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 9583.41574 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38182 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38182 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38182 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38182 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38182 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7519.79510 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8759.23812 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38182 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38182 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7519.79510 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78202 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 8759.23812 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38650 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38650 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38650 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38650 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38650 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7573.43889 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8866.20637 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38650 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38650 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7573.43889 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78459 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 8866.20637 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35794 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35794 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35794 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35794 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35794 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6882.67908 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8213.27307 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35794 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35794 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6882.67908 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79250 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 8213.27307 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35675 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35675 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35675 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35675 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35675 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6864.55831 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8186.05394 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35675 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35675 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6864.55831 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79228 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 8186.05394 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35323 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35323 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35323 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35323 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35323 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6833.72535 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8105.67480 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35323 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35323 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6833.72535 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78958 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 8105.67480 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35204 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35204 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35204 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35204 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35204 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6815.74070 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8078.42318 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35204 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35204 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6815.74070 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78935 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 8078.42318 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 6321.0 | 3.22 | 11.00 | 11.44 | 10.82 | 10.85 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 6320.0 | 3.22 | 10.98 | 11.43 | 10.81 | 10.83 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 7089.1 | 3.21 | 10.96 | 11.41 | 10.79 | 10.80 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 6095.3 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 5491.1 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 5486.2 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 5514.0 | 3.23 | 11.03 | 11.48 | 10.85 | 10.90 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 5547.8 | 3.23 | 11.02 | 11.47 | 10.85 | 10.89 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 14075.0 | 3.22 | 10.99 | 11.44 | 10.82 | 10.85 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 14085.5 | 3.22 | 10.98 | 11.43 | 10.81 | 10.83 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 13515.5 | 3.23 | 11.02 | 11.47 | 10.85 | 10.89 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 13517.0 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 12103.1 | 3.22 | 11.00 | 11.45 | 10.83 | 10.86 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 12090.9 | 3.22 | 11.00 | 11.45 | 10.83 | 10.86 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 12129.8 | 3.23 | 11.02 | 11.46 | 10.84 | 10.88 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 12117.9 | 3.23 | 11.02 | 11.47 | 10.85 | 10.88 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 7673.7 | 3.22 | 10.99 | 11.44 | 10.82 | 10.84 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 7726.6 | 3.22 | 10.98 | 11.43 | 10.81 | 10.83 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 7219.8 | 3.23 | 11.02 | 11.47 | 10.85 | 10.89 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 7269.8 | 3.23 | 11.01 | 11.46 | 10.84 | 10.88 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 6601.6 | 3.22 | 10.98 | 11.42 | 10.80 | 10.82 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 6584.4 | 3.22 | 10.98 | 11.42 | 10.81 | 10.83 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 6556.3 | 3.22 | 10.99 | 11.43 | 10.82 | 10.84 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 6539.2 | 3.22 | 10.99 | 11.44 | 10.82 | 10.84 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.200 | 1.017 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.200 | 1.017 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.854 | 0.757 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.854 | 0.757 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6811531810E-007 | 1.3101859983E-006 | Pass | Pass | 8.2003430601E-003 | 9.5316942965E-003 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.1804731708E-007 | 1.6867669419E-006 | Pass | Pass | 7.7819528691E-003 | 9.8308303581E-003 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 6.5876479921E-003 | 2.3633165293E-002 | Pass | Pass | 0.1550658318 | 0.4683743805 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.4150645734E-007 | 1.8903991534E-006 | Pass | Pass | 7.7178926616E-003 | 9.8400595112E-003 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7360843835E-007 | 1.4375233590E-006 | Pass | Pass | 6.4389779399E-003 | 1.0924895006E-002 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7446371270E-007 | 1.4408542086E-006 | Pass | Pass | 6.4380951448E-003 | 1.0923236881E-002 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.2727366399E-007 | 1.0873878058E-006 | Pass | Pass | 6.8336770495E-003 | 1.0425587823E-002 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4091738582E-007 | 1.2000746186E-006 | Pass | Pass | 5.9808507149E-003 | 8.9671710170E-003 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.2083883276E-007 | 1.6968049624E-006 | Pass | Pass | 9.9942493838E-003 | 1.0577166494E-002 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.5583359646E-007 | 1.9758961325E-006 | Pass | Pass | 9.4344281985E-003 | 1.0852107896E-002 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.5507501092E-007 | 1.9749314558E-006 | Pass | Pass | 9.9778855856E-003 | 1.0727501552E-002 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.9085586673E-007 | 2.2674043425E-006 | Pass | Pass | 9.3484929112E-003 | 1.0897549172E-002 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0823713685E-007 | 1.6959211480E-006 | Pass | Pass | 7.6302180453E-003 | 1.1929306392E-002 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0788489272E-007 | 1.6989062001E-006 | Pass | Pass | 7.6317066134E-003 | 1.1927239882E-002 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7190888908E-007 | 1.4066097649E-006 | Pass | Pass | 8.2397221632E-003 | 1.1533803212E-002 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7131635726E-007 | 1.4137461291E-006 | Pass | Pass | 8.2424176977E-003 | 1.1534328775E-002 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.0449435030E-007 | 2.9129981010E-006 | Pass | Pass | 1.5306964404E-002 | 1.2442015574E-002 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.2251579061E-007 | 3.0789761546E-006 | Pass | Pass | 1.4351306838E-002 | 1.2367208728E-002 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 5.6081879745E-007 | 3.4292972873E-006 | Pass | Pass | 1.5251911757E-002 | 1.2697102695E-002 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 5.7862810294E-007 | 3.5991614301E-006 | Pass | Pass | 1.4284187610E-002 | 1.2395420157E-002 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5889094065E-007 | 2.6988264756E-006 | Pass | Pass | 1.2035524411E-002 | 1.2412268634E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5852491831E-007 | 2.7095459588E-006 | Pass | Pass | 1.2033450924E-002 | 1.2419455765E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.3438774624E-007 | 2.4919894954E-006 | Pass | Pass | 1.3128667988E-002 | 1.2452880478E-002 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.3344330952E-007 | 2.5043952339E-006 | Pass | Pass | 1.3130627705E-002 | 1.2464534641E-002 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 1.0892790001E-002 | 6.7873114061E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 4.0026312556E-002 | 9.1385880784E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 2.7979425983E-003 | 1.8159249955E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1563.59 | -175.4 | 0.00 | -11.3 | 2819.47 | 4196.41 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10 | 0.00 | 20.10 | Wetbulb [C] | 1.80 | 0.00 |
| HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20 | 8.50 | 25.80 | Wetbulb [C] | 4.10 | 160.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 57.00 | 12 | |||
| Feb | 0.00 | 0 | |||
| Mar | 153.60 | 31 | |||
| Apr | 87.00 | 59 | |||
| May | 227.22 | 128 | |||
| Jun | 144.58 | 109 | |||
| Jul | 42.40 | 24 | |||
| Aug | 164.90 | 163 | |||
| Sep | 119.60 | 50 | |||
| Oct | 365.70 | 188 | |||
| Nov | 70.90 | 67 | |||
| Dec | 0.00 | 0 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.5369_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 3.053 | 0.251 | 0.251 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.5369_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 3.053 | 0.251 | 0.251 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.5369_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 3.053 | 0.251 | 0.251 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 3.053 | 0.251 | 0.251 | |||||||||||||||||
| North Total or Average | 112.97 | 3.053 | 0.251 | 0.251 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 3.053 | 0.251 | 0.251 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.83 | 83.83 | 50.10 | |
| Exterior Lighting Total | 3183.33 | 50.10 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6587.71 | 5195.98 | 1391.73 | 0.79 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6588.23 | 5207.91 | 1380.33 | 0.79 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7393.40 | 5877.87 | 1515.53 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6350.73 | 4988.91 | 1361.83 | 0.79 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5721.17 | 4494.23 | 1226.95 | 0.79 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5715.94 | 4489.57 | 1226.37 | 0.79 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5742.80 | 4488.40 | 1254.40 | 0.78 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5778.35 | 4518.95 | 1259.41 | 0.78 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14669.54 | 11574.91 | 3094.63 | 0.79 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14683.12 | 11605.40 | 3077.72 | 0.79 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14077.78 | 11014.69 | 3063.09 | 0.78 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14082.39 | 11054.96 | 3027.42 | 0.79 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12611.88 | 9920.07 | 2691.81 | 0.79 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12599.06 | 9908.65 | 2690.40 | 0.79 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12635.70 | 9908.54 | 2727.17 | 0.78 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12623.13 | 9897.23 | 2725.91 | 0.78 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7998.24 | 6313.79 | 1684.45 | 0.79 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8054.78 | 6369.22 | 1685.56 | 0.79 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7519.80 | 5880.63 | 1639.17 | 0.78 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7573.44 | 5942.05 | 1631.39 | 0.78 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6882.68 | 5454.56 | 1428.12 | 0.79 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6864.56 | 5438.68 | 1425.87 | 0.79 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6833.73 | 5395.77 | 1437.95 | 0.79 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6815.74 | 5379.98 | 1435.77 | 0.79 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 6321.0 | 3.22 | 11.00 | 11.44 | 10.82 | 10.85 | |
| SPLIT GNW COOLING COIL | 6320.0 | 3.22 | 10.98 | 11.43 | 10.81 | 10.83 | |
| SPLIT OFFICE COOLING COIL | 7089.1 | 3.21 | 10.96 | 11.41 | 10.79 | 10.80 | |
| SPLIT GNE COOLING COIL | 6095.3 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 | |
| SPLIT GN1 COOLING COIL | 5491.1 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 | |
| SPLIT GN2 COOLING COIL | 5486.2 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 | |
| SPLIT GS1 COOLING COIL | 5514.0 | 3.23 | 11.03 | 11.48 | 10.85 | 10.90 | |
| SPLIT GS2 COOLING COIL | 5547.8 | 3.23 | 11.02 | 11.47 | 10.85 | 10.89 | |
| SPLIT MSW COOLING COIL | 14075.0 | 3.22 | 10.99 | 11.44 | 10.82 | 10.85 | |
| SPLIT MNW COOLING COIL | 14085.5 | 3.22 | 10.98 | 11.43 | 10.81 | 10.83 | |
| SPLIT MSE COOLING COIL | 13515.5 | 3.23 | 11.02 | 11.47 | 10.85 | 10.89 | |
| SPLIT MNE COOLING COIL | 13517.0 | 3.23 | 11.01 | 11.46 | 10.84 | 10.87 | |
| SPLIT MN1 COOLING COIL | 12103.1 | 3.22 | 11.00 | 11.45 | 10.83 | 10.86 | |
| SPLIT MN2 COOLING COIL | 12090.9 | 3.22 | 11.00 | 11.45 | 10.83 | 10.86 | |
| SPLIT MS1 COOLING COIL | 12129.8 | 3.23 | 11.02 | 11.46 | 10.84 | 10.88 | |
| SPLIT MS2 COOLING COIL | 12117.9 | 3.23 | 11.02 | 11.47 | 10.85 | 10.88 | |
| SPLIT TSW COOLING COIL | 7673.7 | 3.22 | 10.99 | 11.44 | 10.82 | 10.84 | |
| SPLIT TNW COOLING COIL | 7726.6 | 3.22 | 10.98 | 11.43 | 10.81 | 10.83 | |
| SPLIT TSE COOLING COIL | 7219.8 | 3.23 | 11.02 | 11.47 | 10.85 | 10.89 | |
| SPLIT TNE COOLING COIL | 7269.8 | 3.23 | 11.01 | 11.46 | 10.84 | 10.88 | |
| SPLIT TN1 COOLING COIL | 6601.6 | 3.22 | 10.98 | 11.42 | 10.80 | 10.82 | |
| SPLIT TN2 COOLING COIL | 6584.4 | 3.22 | 10.98 | 11.42 | 10.81 | 10.83 | |
| SPLIT TS1 COOLING COIL | 6556.3 | 3.22 | 10.99 | 11.43 | 10.82 | 10.84 | |
| SPLIT TS2 COOLING COIL | 6539.2 | 3.22 | 10.99 | 11.44 | 10.82 | 10.84 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 7794.16 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 7838.03 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 8904.81 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 7463.05 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 6725.89 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 6717.70 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 6687.08 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 6738.64 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 17365.81 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 17456.09 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 16423.16 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 16513.33 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 14868.73 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 14848.67 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 14783.00 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 14762.90 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 9476.10 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 9583.42 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 8759.24 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 8866.21 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 8213.27 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 8186.05 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 8105.67 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 8078.42 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 380.39 | 1120.11 | 1.00 | 1.81 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 382.54 | 1120.11 | 1.00 | 1.81 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 434.09 | 1120.11 | 1.00 | 1.73 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 364.17 | 1120.11 | 1.00 | 1.84 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 328.04 | 1120.11 | 1.00 | 1.91 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 327.64 | 1120.11 | 1.00 | 1.91 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 326.14 | 1120.11 | 1.00 | 1.92 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 328.67 | 1120.11 | 1.00 | 1.91 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.76 | 847.88 | 1120.11 | 1.00 | 1.45 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.76 | 852.31 | 1120.11 | 1.00 | 1.45 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.72 | 801.69 | 1120.11 | 1.00 | 1.47 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.72 | 806.11 | 1120.11 | 1.00 | 1.47 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.65 | 725.52 | 1120.11 | 1.00 | 1.50 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.65 | 724.54 | 1120.11 | 1.00 | 1.50 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.64 | 721.32 | 1120.11 | 1.00 | 1.50 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.64 | 720.33 | 1120.11 | 1.00 | 1.50 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 462.81 | 1120.11 | 1.00 | 1.70 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 468.07 | 1120.11 | 1.00 | 1.69 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 427.68 | 1120.11 | 1.00 | 1.74 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 432.92 | 1120.11 | 1.00 | 1.74 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 400.93 | 1120.11 | 1.00 | 1.78 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 399.59 | 1120.11 | 1.00 | 1.78 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 395.66 | 1120.11 | 1.00 | 1.79 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 394.32 | 1120.11 | 1.00 | 1.79 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 4008.99 | 4810.79 | 54.51 | 0.283 | 0.340 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00860 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G NW APARTMENT | 4031.04 | 4837.25 | 54.81 | 0.285 | 0.342 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00856 | 31.89 | 0.01715 | 0.026 | 0.00 |
| OFFICE | 4505.67 | 5406.81 | 61.27 | 0.323 | 0.388 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:00:00 | 23.90 | 23.90 | 0.00835 | 30.53 | 0.01715 | 0.038 | 0.00 |
| G NE APARTMENT | 3841.82 | 4610.18 | 52.24 | 0.271 | 0.325 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00862 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G N1 APARTMENT | 3469.26 | 4163.12 | 47.17 | 0.244 | 0.293 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00851 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G N2 APARTMENT | 3465.13 | 4158.16 | 47.12 | 0.244 | 0.293 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00851 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G S1 APARTMENT | 3449.63 | 4139.56 | 46.91 | 0.243 | 0.291 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00858 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G S2 APARTMENT | 3475.52 | 4170.62 | 47.26 | 0.245 | 0.293 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00858 | 31.89 | 0.01715 | 0.026 | 0.00 |
| M SW APARTMENT | 8910.71 | 10692.85 | 121.17 | 0.631 | 0.757 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00869 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M NW APARTMENT | 8956.26 | 10747.51 | 121.79 | 0.634 | 0.761 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00866 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M SE APARTMENT | 8436.50 | 10123.80 | 114.72 | 0.596 | 0.716 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00876 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M NE APARTMENT | 8481.91 | 10178.30 | 115.34 | 0.600 | 0.720 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00873 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M N1 APARTMENT | 7655.62 | 9186.75 | 104.10 | 0.540 | 0.648 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00859 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M N2 APARTMENT | 7645.42 | 9174.50 | 103.96 | 0.539 | 0.647 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00859 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M S1 APARTMENT | 7612.04 | 9134.45 | 103.51 | 0.537 | 0.644 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00865 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M S2 APARTMENT | 7601.81 | 9122.18 | 103.37 | 0.536 | 0.643 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00865 | 31.89 | 0.01715 | 0.052 | 0.00 |
| T SW APARTMENT | 4858.44 | 5830.13 | 66.06 | 0.344 | 0.413 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00875 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T NW APARTMENT | 4912.78 | 5895.34 | 66.80 | 0.348 | 0.418 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00872 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T SE APARTMENT | 4495.89 | 5395.06 | 61.13 | 0.318 | 0.382 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00883 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T NE APARTMENT | 4549.92 | 5459.91 | 61.87 | 0.322 | 0.387 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00879 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T N1 APARTMENT | 4220.96 | 5065.15 | 57.40 | 0.298 | 0.358 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00858 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T N2 APARTMENT | 4207.24 | 5048.68 | 57.21 | 0.297 | 0.357 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00858 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T S1 APARTMENT | 4166.72 | 5000.06 | 56.66 | 0.294 | 0.353 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00862 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T S2 APARTMENT | 4152.99 | 4983.58 | 56.47 | 0.293 | 0.352 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00862 | 31.89 | 0.01715 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 24.89 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.38 | 0.01815 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.000 | 0.038 | 00:10:00 | 21.10 | 22.62 | 0.01480 | 20.10 | 0.01480 | 0.038 | 0.00 | |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.38 | 0.01815 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.99 | 0.02052 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.99 | 0.02052 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.41 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.12 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.21 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.83 | 0.01735 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.21 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.83 | 0.01735 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 26.73 | 0.01929 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 26.73 | 0.01929 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 26.07 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 26.07 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.53 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.20 | 0.01620 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.53 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.20 | 0.01620 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.84 | 0.01719 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.84 | 0.01719 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.11 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.11 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.34 | 0.34 | 0.03 | 0.03 | 0.3396 | 0.3396 | 0.3396 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.34 | 0.34 | 0.03 | 0.03 | 0.3415 | 0.3415 | 0.3415 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.39 | 0.39 | 0.04 | 0.04 | 0.3875 | 0.3875 | 0.3875 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.33 | 0.33 | 0.03 | 0.03 | 0.3251 | 0.3251 | 0.3251 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.29 | 0.29 | 0.03 | 0.03 | 0.2929 | 0.2929 | 0.2929 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.29 | 0.29 | 0.03 | 0.03 | 0.2925 | 0.2925 | 0.2925 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.29 | 0.29 | 0.03 | 0.03 | 0.2912 | 0.2912 | 0.2912 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.29 | 0.29 | 0.03 | 0.03 | 0.2934 | 0.2934 | 0.2934 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.76 | 0.76 | 0.05 | 0.05 | 0.7570 | 0.7570 | 0.7570 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.76 | 0.76 | 0.05 | 0.05 | 0.7609 | 0.7609 | 0.7609 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.72 | 0.72 | 0.05 | 0.05 | 0.7157 | 0.7157 | 0.7157 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.72 | 0.72 | 0.05 | 0.05 | 0.7197 | 0.7197 | 0.7197 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.65 | 0.65 | 0.05 | 0.05 | 0.6477 | 0.6477 | 0.6477 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.65 | 0.65 | 0.05 | 0.05 | 0.6468 | 0.6468 | 0.6468 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.64 | 0.64 | 0.05 | 0.05 | 0.6440 | 0.6440 | 0.6440 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.64 | 0.64 | 0.05 | 0.05 | 0.6431 | 0.6431 | 0.6431 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.41 | 0.41 | 0.03 | 0.03 | 0.4132 | 0.4132 | 0.4132 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.42 | 0.42 | 0.03 | 0.03 | 0.4179 | 0.4179 | 0.4179 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.38 | 0.38 | 0.03 | 0.03 | 0.3818 | 0.3818 | 0.3818 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.39 | 0.39 | 0.03 | 0.03 | 0.3865 | 0.3865 | 0.3865 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.36 | 0.36 | 0.03 | 0.03 | 0.3579 | 0.3579 | 0.3579 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.36 | 0.36 | 0.03 | 0.03 | 0.3567 | 0.3567 | 0.3567 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.35 | 0.35 | 0.03 | 0.03 | 0.3532 | 0.3532 | 0.3532 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.35 | 0.35 | 0.03 | 0.03 | 0.3520 | 0.3520 | 0.3520 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6587.714 | 5195.979 | 0.339602 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6436.52 | 5313.24 | 0.339602 | 25.55 | 17.56 | 0.00925708 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.6426 | 24.00 | 0.00860378 | 46.2896 | 4008.99 | 0.00 | 6586.59 | 5191.01 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 7794.162 | 7794.162 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 7794.16 | 7794.16 | 0.339602 | 21.02 | 15.32 | 0.00851957 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.6426 | 24.89 | 0.01479830 | 74.7367 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 6588.230 | 5207.905 | 0.341521 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6431.71 | 5338.60 | 0.341521 | 25.55 | 17.53 | 0.00921727 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.5997 | 24.00 | 0.00856467 | 46.0817 | 4031.04 | 0.00 | 6587.11 | 5201.99 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 7838.034 | 7838.034 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 7838.03 | 7838.03 | 0.341521 | 21.02 | 15.32 | 0.00851665 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.5997 | 25.38 | 0.01815189 | 88.5603 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 7393.403 | 5877.869 | 0.387547 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | 7285.71 | 6043.07 | 0.387547 | 25.51 | 17.52 | 0.00921960 | 12.80 | 11.59 | 0.00800000 | 30.53 | 0.01714924 | 24.64 | 9.8326 | 23.90 | 0.00834748 | 45.1966 | 4493.03 | 0.00 | 7392.15 | 5871.27 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 8904.809 | 8904.809 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8904.81 | 8904.81 | 0.387547 | 21.00 | 15.45 | 0.00866845 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8326 | 22.62 | 0.01479830 | 85.6823 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 6350.732 | 4988.905 | 0.325116 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6211.51 | 5098.66 | 0.325116 | 25.57 | 17.60 | 0.00929984 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.9832 | 24.00 | 0.00861862 | 46.3683 | 3841.82 | 0.00 | 6349.65 | 4982.93 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 7463.054 | 7463.054 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 7463.05 | 7463.05 | 0.325116 | 21.02 | 15.34 | 0.00854272 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.9832 | 25.38 | 0.01815189 | 88.5603 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 5721.173 | 4494.228 | 0.292868 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5596.04 | 4610.89 | 0.292868 | 25.63 | 17.60 | 0.00927748 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.8622 | 24.00 | 0.00851178 | 45.8002 | 3469.26 | 0.00 | 5720.20 | 4488.83 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 6725.893 | 6725.893 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6725.89 | 6725.89 | 0.292868 | 21.01 | 15.39 | 0.00860248 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.8622 | 25.99 | 0.02052466 | 96.2474 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 5715.942 | 4489.568 | 0.292509 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5591.18 | 4605.64 | 0.292509 | 25.63 | 17.61 | 0.00927951 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.8731 | 24.00 | 0.00851298 | 45.8066 | 3465.13 | 0.00 | 5714.97 | 4484.12 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 6717.704 | 6717.704 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6717.70 | 6717.70 | 0.292509 | 21.01 | 15.39 | 0.00860322 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.8731 | 25.99 | 0.02052466 | 96.2474 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5742.800 | 4488.401 | 0.291169 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5625.30 | 4590.44 | 0.291169 | 25.64 | 17.66 | 0.00934821 | 12.80 | 11.59 | 0.00800000 | 31.88 | 0.01715183 | 24.99 | 8.9139 | 24.00 | 0.00858453 | 46.1869 | 3449.63 | 0.00 | 5741.82 | 4483.30 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 6687.078 | 6687.078 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6687.08 | 6687.08 | 0.291169 | 21.01 | 15.40 | 0.00860599 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.9139 | 25.41 | 0.01479830 | 72.4773 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5778.351 | 4518.946 | 0.293425 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5658.79 | 4623.60 | 0.293425 | 25.63 | 17.65 | 0.00933850 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.8454 | 24.00 | 0.00858032 | 46.1646 | 3475.52 | 0.00 | 5777.37 | 4514.09 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 6738.642 | 6738.642 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6738.64 | 6738.64 | 0.293425 | 21.01 | 15.39 | 0.00860133 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.8454 | 25.12 | 0.01479830 | 73.7106 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 14669.540 | 11574.913 | 0.756964 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 14330.25 | 11798.33 | 0.756964 | 25.49 | 17.55 | 0.00927126 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.8575 | 24.00 | 0.00869106 | 46.7535 | 17821.42 | 0.00 | 14667.04 | 11564.30 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 17365.815 | 17365.815 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 17365.81 | 17365.81 | 0.756964 | 21.03 | 15.28 | 0.00846620 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.8575 | 25.21 | 0.01479830 | 73.3436 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 14683.117 | 11605.399 | 0.760913 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 14334.39 | 11851.81 | 0.760913 | 25.49 | 17.53 | 0.00924067 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.8219 | 24.00 | 0.00866146 | 46.5962 | 17912.51 | 0.00 | 14680.62 | 11592.08 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 17456.094 | 17456.094 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 17456.09 | 17456.09 | 0.760913 | 21.03 | 15.28 | 0.00846378 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.8219 | 25.83 | 0.01735426 | 82.5443 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 14077.778 | 11014.692 | 0.715725 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 13782.98 | 11196.04 | 0.715725 | 25.52 | 17.64 | 0.00937129 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.2527 | 24.00 | 0.00876287 | 47.1347 | 16873.00 | 0.00 | 14075.38 | 11003.38 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 16423.161 | 16423.161 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 16423.16 | 16423.16 | 0.715725 | 21.03 | 15.30 | 0.00849306 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.2527 | 25.21 | 0.01479830 | 73.3436 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 14082.388 | 11054.963 | 0.719670 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 13776.78 | 11248.75 | 0.719670 | 25.52 | 17.61 | 0.00933355 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.2129 | 24.00 | 0.00872578 | 46.9377 | 16963.83 | 0.00 | 14079.99 | 11045.31 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 16513.333 | 16513.333 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 16513.33 | 16513.33 | 0.719670 | 21.03 | 15.30 | 0.00849035 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.2129 | 25.83 | 0.01735426 | 82.5443 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 12611.884 | 9920.074 | 0.647723 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 12329.52 | 10156.12 | 0.647723 | 25.58 | 17.58 | 0.00927471 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.0141 | 24.00 | 0.00858843 | 46.2077 | 15311.24 | 0.00 | 12609.74 | 9909.46 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 14868.733 | 14868.733 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 14868.73 | 14868.73 | 0.647723 | 21.02 | 15.34 | 0.00854482 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.0141 | 26.73 | 0.01928694 | 86.7371 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 12599.057 | 9908.654 | 0.646845 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 12317.61 | 10143.23 | 0.646845 | 25.58 | 17.58 | 0.00927696 | 12.80 | 11.59 | 0.00800000 | 31.88 | 0.01715183 | 24.99 | 8.0250 | 24.00 | 0.00858987 | 46.2153 | 15290.83 | 0.00 | 12596.91 | 9897.92 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 14848.674 | 14848.674 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 14848.67 | 14848.67 | 0.646845 | 21.02 | 15.35 | 0.00854556 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.0250 | 26.73 | 0.01928694 | 86.7371 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 12635.705 | 9908.539 | 0.643972 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 12367.07 | 10108.64 | 0.643972 | 25.58 | 17.63 | 0.00933105 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.0608 | 24.00 | 0.00864536 | 46.5102 | 15224.08 | 0.00 | 12633.55 | 9898.77 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 14783.000 | 14783.000 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 14783.00 | 14783.00 | 0.643972 | 21.02 | 15.35 | 0.00854800 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.0608 | 26.07 | 0.01479830 | 69.7056 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 12623.133 | 9897.228 | 0.643093 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 12355.46 | 10095.75 | 0.643093 | 25.58 | 17.63 | 0.00933357 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.0718 | 24.00 | 0.00864708 | 46.5193 | 15203.63 | 0.00 | 12620.99 | 9887.32 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 14762.896 | 14762.896 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 14762.90 | 14762.90 | 0.643093 | 21.02 | 15.35 | 0.00854874 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.0718 | 26.07 | 0.01479830 | 69.7056 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 7998.238 | 6313.788 | 0.413182 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 7811.76 | 6424.01 | 0.413182 | 25.46 | 17.54 | 0.00927663 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.2816 | 24.00 | 0.00874878 | 47.0604 | 4858.44 | 0.00 | 7996.88 | 6308.29 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 9476.097 | 9476.097 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 9476.10 | 9476.10 | 0.413182 | 21.04 | 15.25 | 0.00842704 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.2816 | 22.53 | 0.01479830 | 86.1431 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 8054.776 | 6369.217 | 0.417877 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 7862.00 | 6491.57 | 0.417877 | 25.45 | 17.52 | 0.00924718 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.2111 | 24.00 | 0.00872371 | 46.9272 | 4912.78 | 0.00 | 8053.40 | 6362.18 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 9583.416 | 9583.416 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 9583.42 | 9583.42 | 0.417877 | 21.04 | 15.24 | 0.00842225 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.2111 | 23.20 | 0.01619581 | 90.3519 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 7519.795 | 5880.627 | 0.381821 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 7363.61 | 5962.78 | 0.381821 | 25.49 | 17.65 | 0.00939165 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.7976 | 24.00 | 0.00882568 | 47.4684 | 4495.89 | 0.00 | 7518.52 | 5874.29 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 8759.238 | 8759.238 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8759.24 | 8759.24 | 0.381821 | 21.03 | 15.27 | 0.00846212 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.7976 | 22.53 | 0.01479830 | 86.1431 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 7573.439 | 5942.054 | 0.386501 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 7410.46 | 6029.92 | 0.386501 | 25.49 | 17.62 | 0.00935571 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.7153 | 24.00 | 0.00879450 | 47.3029 | 4549.92 | 0.00 | 7572.15 | 5936.53 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 8866.206 | 8866.206 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8866.21 | 8866.21 | 0.386501 | 21.03 | 15.27 | 0.00845652 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.7153 | 23.20 | 0.01619581 | 90.3519 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 6882.679 | 5454.557 | 0.357937 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6715.87 | 5585.60 | 0.357937 | 25.53 | 17.51 | 0.00920137 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.2512 | 24.00 | 0.00857980 | 46.1620 | 4220.96 | 0.00 | 6881.51 | 5448.96 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 8213.273 | 8213.273 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8213.27 | 8213.27 | 0.357937 | 21.03 | 15.30 | 0.00849296 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.2512 | 23.84 | 0.01719083 | 92.0953 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 6864.558 | 5438.685 | 0.356746 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6698.89 | 5568.12 | 0.356746 | 25.53 | 17.51 | 0.00920580 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.2754 | 24.00 | 0.00858234 | 46.1755 | 4207.24 | 0.00 | 6863.39 | 5432.95 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 8186.054 | 8186.054 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8186.05 | 8186.05 | 0.356746 | 21.03 | 15.30 | 0.00849460 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.2754 | 23.84 | 0.01719083 | 92.0953 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 6833.725 | 5395.774 | 0.353229 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6674.16 | 5518.74 | 0.353229 | 25.53 | 17.54 | 0.00924353 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.3478 | 24.00 | 0.00861636 | 46.3563 | 4166.72 | 0.00 | 6832.56 | 5391.20 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 8105.675 | 8105.675 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8105.67 | 8105.67 | 0.353229 | 21.03 | 15.31 | 0.00849952 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.3478 | 23.11 | 0.01479830 | 83.1989 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 6815.741 | 5379.976 | 0.352037 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6657.34 | 5501.25 | 0.352037 | 25.54 | 17.55 | 0.00924835 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.3727 | 24.00 | 0.00861928 | 46.3717 | 4152.99 | 0.00 | 6814.58 | 5375.25 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 8078.423 | 8078.423 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 8078.42 | 8078.42 | 0.352037 | 21.03 | 15.31 | 0.00850122 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.3727 | 23.11 | 0.01479830 | 83.1989 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6587.714 | 5195.979 | 0.339602 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0485 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.339602 | 0.40874272 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6436.52 | 5313.24 | 0.9770 | 0.40874272 | 0.339602 | 25.55 | 17.56 | 0.00925708 | 49265.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 380.390 | 6056.13 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.6426 | 24.04 | 0.00860378 | 24.00 | 0.00860378 | 46.2896 | 4008.99 | 0.00 | 6586.59 | 5191.01 | 0.39260047 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.74 | 13.73 | 0.00979094 | 38545.6 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7794.162 | 7794.162 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.339602 | 0.40874272 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 7794.16 | 7794.16 | 1.0000 | 0.40874272 | 0.339602 | 21.02 | 15.32 | 0.00851957 | 42765.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7794.16 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.6426 | 21.10 | 0.00800000 | 24.89 | 0.01479830 | 74.7367 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6588.230 | 5207.905 | 0.341521 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9744 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.341521 | 0.41105278 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6431.71 | 5338.60 | 0.9762 | 0.41105278 | 0.341521 | 25.55 | 17.53 | 0.00921727 | 49160.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 382.540 | 6049.17 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.5997 | 24.04 | 0.00856467 | 24.00 | 0.00856467 | 46.0817 | 4031.04 | 0.00 | 6587.11 | 5201.99 | 0.39481930 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.79 | 13.77 | 0.00980916 | 38638.5 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7838.034 | 7838.034 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.341521 | 0.41105278 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 7838.03 | 7838.03 | 1.0000 | 0.41105278 | 0.341521 | 21.02 | 15.32 | 0.00851665 | 42758.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7838.03 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.5997 | 21.10 | 0.00800000 | 25.38 | 0.01815189 | 88.5603 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7393.403 | 5877.869 | 0.387547 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9788 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.387547 | 0.46644916 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | Sensible | 7285.71 | 6043.07 | 0.9854 | 0.46644916 | 0.387547 | 25.51 | 17.52 | 0.00921960 | 49130.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 434.094 | 6851.62 | 30.53 | 0.01714924 | 24.64 | 0.03810604 | 9.8326 | 23.96 | 0.00835489 | 23.90 | 0.00834748 | 45.1966 | 4493.03 | 0.00 | 7392.15 | 5871.27 | 0.44802794 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.86 | 13.84 | 0.00985372 | 38823.1 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8904.809 | 8904.809 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.387547 | 0.46644916 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8904.81 | 8904.81 | 1.0000 | 0.46644916 | 0.387547 | 21.00 | 15.45 | 0.00866845 | 43121.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8904.81 | 20.10 | 0.01479830 | 20.10 | 0.03810604 | 9.8326 | 21.10 | 0.00800000 | 22.62 | 0.01479830 | 85.6823 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6350.732 | 4988.905 | 0.325116 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.1279 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.325116 | 0.39130850 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6211.51 | 5098.66 | 0.9781 | 0.39130850 | 0.325116 | 25.57 | 17.60 | 0.00929984 | 49398.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 364.165 | 5847.35 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.9832 | 24.04 | 0.00861862 | 24.00 | 0.00861862 | 46.3683 | 3841.82 | 0.00 | 6349.65 | 4982.93 | 0.37585477 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.71 | 13.69 | 0.00975895 | 38428.5 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7463.054 | 7463.054 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.325116 | 0.39130850 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 7463.05 | 7463.05 | 1.0000 | 0.39130850 | 0.325116 | 21.02 | 15.34 | 0.00854272 | 42820.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7463.05 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.9832 | 21.10 | 0.00800000 | 25.38 | 0.01815189 | 88.5603 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5721.173 | 4494.228 | 0.292868 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0864 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.292868 | 0.35249387 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5596.04 | 4610.89 | 0.9781 | 0.35249387 | 0.292868 | 25.63 | 17.60 | 0.00927748 | 49402.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 328.043 | 5267.99 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.8622 | 24.03 | 0.00851178 | 24.00 | 0.00851178 | 45.8002 | 3469.26 | 0.00 | 5720.20 | 4488.83 | 0.33857303 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.71 | 13.69 | 0.00975870 | 38427.4 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6725.893 | 6725.893 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.292868 | 0.35249387 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6725.89 | 6725.89 | 1.0000 | 0.35249387 | 0.292868 | 21.01 | 15.39 | 0.00860248 | 42963.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6725.89 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.8622 | 21.10 | 0.00800000 | 25.99 | 0.02052466 | 96.2474 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5715.942 | 4489.568 | 0.292509 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0901 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.292509 | 0.35206269 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5591.18 | 4605.64 | 0.9782 | 0.35206269 | 0.292509 | 25.63 | 17.61 | 0.00927951 | 49408.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 327.642 | 5263.54 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.8731 | 24.03 | 0.00851298 | 24.00 | 0.00851298 | 45.8066 | 3465.13 | 0.00 | 5714.97 | 4484.12 | 0.33815888 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.70 | 13.69 | 0.00975756 | 38422.1 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6717.704 | 6717.704 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.292509 | 0.35206269 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6717.70 | 6717.70 | 1.0000 | 0.35206269 | 0.292509 | 21.01 | 15.39 | 0.00860322 | 42965.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6717.70 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.8731 | 21.10 | 0.00800000 | 25.99 | 0.02052466 | 96.2474 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5742.800 | 4488.401 | 0.291169 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.2178 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.291169 | 0.35045009 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5625.30 | 4590.44 | 0.9795 | 0.35045009 | 0.291169 | 25.64 | 17.66 | 0.00934821 | 49586.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 326.141 | 5299.16 | 31.88 | 0.01715183 | 24.99 | 0.02595455 | 8.9139 | 24.03 | 0.00858453 | 24.00 | 0.00858453 | 46.1869 | 3449.63 | 0.00 | 5741.82 | 4483.30 | 0.33660996 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.65 | 13.63 | 0.00971876 | 38264.6 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6687.078 | 6687.078 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.291169 | 0.35045009 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6687.08 | 6687.08 | 1.0000 | 0.35045009 | 0.291169 | 21.01 | 15.40 | 0.00860599 | 42971.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6687.08 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.9139 | 21.10 | 0.00800000 | 25.41 | 0.01479830 | 72.4773 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5778.351 | 4518.946 | 0.293425 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.1998 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.293425 | 0.35316512 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5658.79 | 4623.60 | 0.9793 | 0.35316512 | 0.293425 | 25.63 | 17.65 | 0.00933850 | 49556.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 328.668 | 5330.12 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.8454 | 24.03 | 0.00858032 | 24.00 | 0.00858032 | 46.1646 | 3475.52 | 0.00 | 5777.37 | 4514.09 | 0.33921777 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.66 | 13.64 | 0.00972453 | 38290.9 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6738.642 | 6738.642 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.293425 | 0.35316512 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6738.64 | 6738.64 | 1.0000 | 0.35316512 | 0.293425 | 21.01 | 15.39 | 0.00860133 | 42960.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6738.64 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.8454 | 21.10 | 0.00800000 | 25.12 | 0.01479830 | 73.7106 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14669.540 | 11574.913 | 0.756964 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0748 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.756964 | 0.91107787 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 14330.25 | 11798.33 | 0.9769 | 0.91107787 | 0.756964 | 25.49 | 17.55 | 0.00927126 | 49243.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 847.881 | 13482.37 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 6.8575 | 24.05 | 0.00869106 | 24.00 | 0.00869106 | 46.7535 | 17821.42 | 0.00 | 14667.04 | 11564.30 | 0.87509718 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.75 | 13.74 | 0.00979451 | 38561.9 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17365.815 | 17365.815 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.756964 | 0.91107787 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 17365.81 | 17365.81 | 1.0000 | 0.91107787 | 0.756964 | 21.03 | 15.28 | 0.00846620 | 42637.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17365.81 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 6.8575 | 21.10 | 0.00800000 | 25.21 | 0.01479830 | 73.3436 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14683.117 | 11605.399 | 0.760913 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0179 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.760913 | 0.91583143 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 14334.39 | 11851.81 | 0.9763 | 0.91583143 | 0.760913 | 25.49 | 17.53 | 0.00924067 | 49163.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 852.305 | 13482.09 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 6.8219 | 24.05 | 0.00866146 | 24.00 | 0.00866146 | 46.5962 | 17912.51 | 0.00 | 14680.62 | 11592.08 | 0.87966302 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.79 | 13.76 | 0.00980806 | 38633.5 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17456.094 | 17456.094 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.760913 | 0.91583143 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 17456.09 | 17456.09 | 1.0000 | 0.91583143 | 0.760913 | 21.03 | 15.28 | 0.00846378 | 42631.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17456.09 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 6.8219 | 21.10 | 0.00800000 | 25.83 | 0.01735426 | 82.5443 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14077.778 | 11014.692 | 0.715725 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.2608 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.715725 | 0.86144319 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 13782.98 | 11196.04 | 0.9791 | 0.86144319 | 0.715725 | 25.52 | 17.64 | 0.00937129 | 49527.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 801.689 | 12981.30 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 7.2527 | 24.04 | 0.00876287 | 24.00 | 0.00876287 | 47.1347 | 16873.00 | 0.00 | 14075.38 | 11003.38 | 0.82742270 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.67 | 13.64 | 0.00972898 | 38311.3 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16423.161 | 16423.161 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.715725 | 0.86144319 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 16423.16 | 16423.16 | 1.0000 | 0.86144319 | 0.715725 | 21.03 | 15.30 | 0.00849306 | 42701.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16423.16 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.2527 | 21.10 | 0.00800000 | 25.21 | 0.01479830 | 73.3436 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14082.388 | 11054.963 | 0.719670 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.1906 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.719670 | 0.86619112 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 13776.78 | 11248.75 | 0.9783 | 0.86619112 | 0.719670 | 25.52 | 17.61 | 0.00933355 | 49428.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 806.108 | 12970.67 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 7.2129 | 24.04 | 0.00872578 | 24.00 | 0.00872578 | 46.9377 | 16963.83 | 0.00 | 14079.99 | 11045.31 | 0.83198312 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.69 | 13.68 | 0.00975455 | 38399.0 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16513.333 | 16513.333 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.719670 | 0.86619112 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 16513.33 | 16513.33 | 1.0000 | 0.86619112 | 0.719670 | 21.03 | 15.30 | 0.00849035 | 42695.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16513.33 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.2129 | 21.10 | 0.00800000 | 25.83 | 0.01735426 | 82.5443 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12611.884 | 9920.074 | 0.647723 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0812 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.647723 | 0.77959595 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 12329.52 | 10156.12 | 0.9776 | 0.77959595 | 0.647723 | 25.58 | 17.58 | 0.00927471 | 49337.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 725.520 | 11604.01 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 8.0141 | 24.04 | 0.00858843 | 24.00 | 0.00858843 | 46.2077 | 15311.24 | 0.00 | 12609.74 | 9909.46 | 0.74880781 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.73 | 13.71 | 0.00977079 | 38482.6 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14868.733 | 14868.733 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.647723 | 0.77959595 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 14868.73 | 14868.73 | 1.0000 | 0.77959595 | 0.647723 | 21.02 | 15.34 | 0.00854482 | 42825.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14868.73 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.0141 | 21.10 | 0.00800000 | 26.73 | 0.01928694 | 86.7371 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12599.057 | 9908.654 | 0.646845 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0854 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.646845 | 0.77853978 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 12317.61 | 10143.23 | 0.9777 | 0.77853978 | 0.646845 | 25.58 | 17.58 | 0.00927696 | 49343.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 724.537 | 11593.08 | 31.88 | 0.01715183 | 24.99 | 0.05190911 | 8.0250 | 24.04 | 0.00858987 | 24.00 | 0.00858987 | 46.2153 | 15290.83 | 0.00 | 12596.91 | 9897.92 | 0.74779334 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.73 | 13.71 | 0.00976955 | 38476.9 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14848.674 | 14848.674 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.646845 | 0.77853978 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 14848.67 | 14848.67 | 1.0000 | 0.77853978 | 0.646845 | 21.02 | 15.35 | 0.00854556 | 42827.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14848.67 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.0250 | 21.10 | 0.00800000 | 26.73 | 0.01928694 | 86.7371 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12635.705 | 9908.539 | 0.643972 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.1860 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.643972 | 0.77508177 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 12367.07 | 10108.64 | 0.9787 | 0.77508177 | 0.643972 | 25.58 | 17.63 | 0.00933105 | 49483.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 721.318 | 11645.75 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 8.0608 | 24.04 | 0.00864536 | 24.00 | 0.00864536 | 46.5102 | 15224.08 | 0.00 | 12633.55 | 9898.77 | 0.74447190 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.67 | 13.66 | 0.00974438 | 38352.6 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14783.000 | 14783.000 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.643972 | 0.77508177 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 14783.00 | 14783.00 | 1.0000 | 0.77508177 | 0.643972 | 21.02 | 15.35 | 0.00854800 | 42833.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14783.00 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.0608 | 21.10 | 0.00800000 | 26.07 | 0.01479830 | 69.7056 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12623.133 | 9897.228 | 0.643093 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.1906 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.643093 | 0.77402322 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 12355.46 | 10095.75 | 0.9788 | 0.77402322 | 0.643093 | 25.58 | 17.63 | 0.00933357 | 49490.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 720.333 | 11635.13 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 8.0718 | 24.04 | 0.00864708 | 24.00 | 0.00864708 | 46.5193 | 15203.63 | 0.00 | 12620.99 | 9887.32 | 0.74345516 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.67 | 13.66 | 0.00974300 | 38346.3 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14762.896 | 14762.896 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.643093 | 0.77402322 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 14762.90 | 14762.90 | 1.0000 | 0.77402322 | 0.643093 | 21.02 | 15.35 | 0.00854874 | 42834.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14762.90 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.0718 | 21.10 | 0.00800000 | 26.07 | 0.01479830 | 69.7056 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7998.238 | 6313.788 | 0.413182 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0848 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.413182 | 0.49730371 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 7811.76 | 6424.01 | 0.9767 | 0.49730371 | 0.413182 | 25.46 | 17.54 | 0.00927663 | 49220.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 462.808 | 7348.95 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 6.2816 | 24.06 | 0.00874878 | 24.00 | 0.00874878 | 47.0604 | 4858.44 | 0.00 | 7996.88 | 6308.29 | 0.47766397 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.76 | 13.74 | 0.00979863 | 38580.7 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9476.097 | 9476.097 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.413182 | 0.49730371 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 9476.10 | 9476.10 | 1.0000 | 0.49730371 | 0.413182 | 21.04 | 15.25 | 0.00842704 | 42544.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9476.10 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.2816 | 21.10 | 0.00800000 | 22.53 | 0.01479830 | 86.1431 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8054.776 | 6369.217 | 0.417877 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0300 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.417877 | 0.50295451 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 7862.00 | 6491.57 | 0.9761 | 0.50295451 | 0.417877 | 25.45 | 17.52 | 0.00924718 | 49141.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 468.067 | 7393.93 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 6.2111 | 24.06 | 0.00872371 | 24.00 | 0.00872371 | 46.9272 | 4912.78 | 0.00 | 8053.40 | 6362.18 | 0.48309161 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.79 | 13.77 | 0.00981206 | 38651.8 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9583.416 | 9583.416 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.417877 | 0.50295451 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 9583.42 | 9583.42 | 1.0000 | 0.50295451 | 0.417877 | 21.04 | 15.24 | 0.00842225 | 42532.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9583.42 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.2111 | 21.10 | 0.00800000 | 23.20 | 0.01619581 | 90.3519 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7519.795 | 5880.627 | 0.381821 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.2986 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.381821 | 0.45955807 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 7363.61 | 5962.78 | 0.9792 | 0.45955807 | 0.381821 | 25.49 | 17.65 | 0.00939165 | 49550.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 427.681 | 6935.93 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 6.7976 | 24.05 | 0.00882568 | 24.00 | 0.00882568 | 47.4684 | 4495.89 | 0.00 | 7518.52 | 5874.29 | 0.44140900 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.66 | 13.63 | 0.00972419 | 38289.4 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8759.238 | 8759.238 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.381821 | 0.45955807 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8759.24 | 8759.24 | 1.0000 | 0.45955807 | 0.381821 | 21.03 | 15.27 | 0.00846212 | 42627.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8759.24 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.7976 | 21.10 | 0.00800000 | 22.53 | 0.01479830 | 86.1431 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7573.439 | 5942.054 | 0.386501 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.2318 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.386501 | 0.46519040 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 7410.46 | 6029.92 | 0.9785 | 0.46519040 | 0.386501 | 25.49 | 17.62 | 0.00935571 | 49452.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 432.923 | 6977.54 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 6.7153 | 24.05 | 0.00879450 | 24.00 | 0.00879450 | 47.3029 | 4549.92 | 0.00 | 7572.15 | 5936.53 | 0.44681890 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.68 | 13.67 | 0.00974942 | 38375.6 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8866.206 | 8866.206 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.386501 | 0.46519040 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8866.21 | 8866.21 | 1.0000 | 0.46519040 | 0.386501 | 21.03 | 15.27 | 0.00845652 | 42614.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8866.21 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.7153 | 21.10 | 0.00800000 | 23.20 | 0.01619581 | 90.3519 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6882.679 | 5454.557 | 0.357937 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9449 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.357937 | 0.43081071 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6715.87 | 5585.60 | 0.9758 | 0.43081071 | 0.357937 | 25.53 | 17.51 | 0.00920137 | 49099.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 400.928 | 6314.95 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.2512 | 24.05 | 0.00857980 | 24.00 | 0.00857980 | 46.1620 | 4220.96 | 0.00 | 6881.51 | 5448.96 | 0.41379694 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.80 | 13.79 | 0.00982730 | 38692.2 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8213.273 | 8213.273 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.357937 | 0.43081071 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8213.27 | 8213.27 | 1.0000 | 0.43081071 | 0.357937 | 21.03 | 15.30 | 0.00849296 | 42701.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8213.27 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.2512 | 21.10 | 0.00800000 | 23.84 | 0.01719083 | 92.0953 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6864.558 | 5438.685 | 0.356746 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9531 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.356746 | 0.42937750 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6698.89 | 5568.12 | 0.9759 | 0.42937750 | 0.356746 | 25.53 | 17.51 | 0.00920580 | 49112.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 399.594 | 6299.29 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.2754 | 24.05 | 0.00858234 | 24.00 | 0.00858234 | 46.1755 | 4207.24 | 0.00 | 6863.39 | 5432.95 | 0.41242034 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.79 | 13.78 | 0.00982478 | 38680.7 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8186.054 | 8186.054 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.356746 | 0.42937750 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8186.05 | 8186.05 | 1.0000 | 0.42937750 | 0.356746 | 21.03 | 15.30 | 0.00849460 | 42705.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8186.05 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.2754 | 21.10 | 0.00800000 | 23.84 | 0.01719083 | 92.0953 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6833.725 | 5395.774 | 0.353229 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0233 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.353229 | 0.42514520 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6674.16 | 5518.74 | 0.9766 | 0.42514520 | 0.353229 | 25.53 | 17.54 | 0.00924353 | 49214.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 395.655 | 6278.50 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.3478 | 24.05 | 0.00861636 | 24.00 | 0.00861636 | 46.3563 | 4166.72 | 0.00 | 6832.56 | 5391.20 | 0.40835518 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.76 | 13.75 | 0.00980076 | 38590.5 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8105.675 | 8105.675 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.353229 | 0.42514520 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8105.67 | 8105.67 | 1.0000 | 0.42514520 | 0.353229 | 21.03 | 15.31 | 0.00849952 | 42717.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8105.67 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.3478 | 21.10 | 0.00800000 | 23.11 | 0.01479830 | 83.1989 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6815.741 | 5379.976 | 0.352037 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0322 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.352037 | 0.42371029 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6657.34 | 5501.25 | 0.9768 | 0.42371029 | 0.352037 | 25.54 | 17.55 | 0.00924835 | 49228.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 394.320 | 6263.02 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.3727 | 24.05 | 0.00861928 | 24.00 | 0.00861928 | 46.3717 | 4152.99 | 0.00 | 6814.58 | 5375.25 | 0.40697693 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.76 | 13.74 | 0.00979803 | 38578.0 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8078.423 | 8078.423 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.352037 | 0.42371029 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 8078.42 | 8078.42 | 1.0000 | 0.42371029 | 0.352037 | 21.03 | 15.31 | 0.00850122 | 42721.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8078.42 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.3727 | 21.10 | 0.00800000 | 23.11 | 0.01479830 | 83.1989 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 6145.00 | 3491.67 | 3491.67 |
| G NW APARTMENT | 8760.00 | 4634.83 | 4634.83 |
| OFFICE | 1750.00 | 332.83 | 332.83 |
| G NE APARTMENT | 8760.00 | 4482.00 | 4482.00 |
| G N1 APARTMENT | 8760.00 | 5212.00 | 5212.00 |
| G N2 APARTMENT | 8760.00 | 5207.67 | 5207.67 |
| G S1 APARTMENT | 6145.00 | 3706.50 | 3706.50 |
| G S2 APARTMENT | 6145.00 | 3088.50 | 3088.50 |
| M SW APARTMENT | 6145.00 | 4105.17 | 4105.17 |
| M NW APARTMENT | 8760.00 | 5605.17 | 5605.17 |
| M SE APARTMENT | 6145.00 | 4102.50 | 4102.50 |
| M NE APARTMENT | 8760.00 | 5490.33 | 5490.33 |
| M N1 APARTMENT | 8760.00 | 5938.33 | 5938.33 |
| M N2 APARTMENT | 8760.00 | 5935.17 | 5935.17 |
| M S1 APARTMENT | 6145.00 | 4247.83 | 4247.83 |
| M S2 APARTMENT | 6145.00 | 4249.33 | 4249.33 |
| T SW APARTMENT | 6144.67 | 4339.83 | 4339.83 |
| T NW APARTMENT | 8759.00 | 5458.17 | 5458.17 |
| T SE APARTMENT | 6144.83 | 4343.50 | 4343.50 |
| T NE APARTMENT | 8759.50 | 5306.00 | 5306.00 |
| T N1 APARTMENT | 8760.00 | 5569.33 | 5569.33 |
| T N2 APARTMENT | 8760.00 | 5565.17 | 5565.17 |
| T S1 APARTMENT | 6145.00 | 4334.50 | 4334.50 |
| T S2 APARTMENT | 6145.00 | 4336.83 | 4336.83 |
| T CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| G CORRIDOR | 8760.00 | 8753.50 | 8753.50 |
| M CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| Facility | 8760.00 | 8760.00 | 8760.00 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 11.00 | 0.00 | 11.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 11.00 | 0.00 | 11.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.102 | 0.000 | 0.006 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.111 | 0.000 | 0.004 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.528 | 0.127 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.111 | 0.000 | 0.004 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.067 | 0.000 | 0.004 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.067 | 0.000 | 0.004 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.061 | 0.000 | 0.006 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.061 | 0.000 | 0.006 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.146 | 0.000 | 0.006 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.159 | 0.000 | 0.005 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.146 | 0.000 | 0.006 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.159 | 0.000 | 0.005 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.096 | 0.000 | 0.005 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.096 | 0.000 | 0.005 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.088 | 0.000 | 0.006 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.088 | 0.000 | 0.006 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.194 | 0.000 | 0.007 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.211 | 0.000 | 0.006 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.194 | 0.000 | 0.007 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.211 | 0.000 | 0.006 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.127 | 0.000 | 0.006 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.127 | 0.000 | 0.006 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.117 | 0.000 | 0.007 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.117 | 0.000 | 0.007 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.518 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.19 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 9691.01 | 828193.79 | 251892.26 | 1080086.05 | 818502.78 | 0.00 | 8539.50 | 220.50 | 2615.00 |
| G NW APARTMENT | 818502.78 | 10205.80 | 828708.57 | 251892.26 | 1080600.83 | 818502.78 | 0.00 | 8539.50 | 220.50 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 251892.26 | 1453604.23 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 10205.80 | 828708.57 | 251892.26 | 1080600.83 | 818502.78 | 0.00 | 8539.50 | 220.50 | 0.00 |
| G N1 APARTMENT | 818502.78 | 10205.79 | 828708.57 | 151935.01 | 980643.59 | 818502.78 | 0.00 | 8539.50 | 220.50 | 0.00 |
| G N2 APARTMENT | 818502.78 | 10205.79 | 828708.57 | 151935.01 | 980643.59 | 818502.78 | 0.00 | 8539.50 | 220.50 | 0.00 |
| G S1 APARTMENT | 818502.78 | 9691.01 | 828193.79 | 151935.01 | 980128.80 | 818502.78 | 0.00 | 8539.50 | 220.50 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 9691.01 | 828193.79 | 151935.01 | 980128.80 | 818502.78 | 0.00 | 8539.50 | 220.50 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 11193.26 | 1648198.82 | 361987.34 | 2010186.16 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 12084.72 | 1649090.27 | 361987.34 | 2011077.61 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 0.00 |
| M SE APARTMENT | 1637005.55 | 11193.26 | 1648198.82 | 361987.34 | 2010186.16 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 12084.72 | 1649090.27 | 361987.34 | 2011077.61 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 12084.71 | 1649090.27 | 218341.57 | 1867431.84 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 12084.71 | 1649090.27 | 218341.57 | 1867431.84 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 11193.26 | 1648198.81 | 218341.57 | 1866540.39 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 11193.26 | 1648198.81 | 218341.57 | 1866540.39 | 1637005.55 | 0.00 | 8535.00 | 225.00 | 2615.00 |
| T SW APARTMENT | 818502.78 | 13176.48 | 831679.25 | 478831.60 | 1310510.86 | 818502.78 | 0.00 | 8528.67 | 231.33 | 2615.00 |
| T NW APARTMENT | 818502.78 | 14488.20 | 832990.97 | 478831.60 | 1311822.58 | 818502.78 | 0.00 | 8528.67 | 231.33 | 0.00 |
| T SE APARTMENT | 818502.78 | 13177.76 | 831680.54 | 478831.60 | 1310512.14 | 818502.78 | 0.00 | 8528.67 | 231.33 | 2615.00 |
| T NE APARTMENT | 818502.78 | 14491.02 | 832993.80 | 478831.60 | 1311825.40 | 818502.78 | 0.00 | 8528.67 | 231.33 | 0.00 |
| T N1 APARTMENT | 818502.78 | 14493.87 | 832996.65 | 288819.07 | 1121815.72 | 818502.78 | 0.00 | 8528.67 | 231.33 | 0.00 |
| T N2 APARTMENT | 818502.78 | 14493.88 | 832996.66 | 288819.07 | 1121815.72 | 818502.78 | 0.00 | 8528.67 | 231.33 | 0.00 |
| T S1 APARTMENT | 818502.78 | 13179.66 | 831682.43 | 288819.07 | 1120501.50 | 818502.78 | 0.00 | 8528.67 | 231.33 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 13179.65 | 831682.43 | 288819.07 | 1120501.50 | 818502.78 | 0.00 | 8528.67 | 231.33 | 2615.00 |
| Total Facility | 39671342.50 | 366800.54 | 40038143.04 | 9328543.08 | 49366686.12 | 39671342.50 | 0.00 | 8760.00 | 231.33 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0073 | 0.0337 | 0.0260 | 0.00 | 5942.33 | 202.67 |
| G NW APARTMENT | 0.0260 | 0.0003 | 0.0263 | 0.0080 | 0.0343 | 0.0260 | 0.00 | 8539.50 | 220.50 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0091 | 0.0472 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0003 | 0.0263 | 0.0080 | 0.0343 | 0.0260 | 0.00 | 8539.50 | 220.50 |
| G N1 APARTMENT | 0.0260 | 0.0003 | 0.0263 | 0.0048 | 0.0311 | 0.0260 | 0.00 | 8539.50 | 220.50 |
| G N2 APARTMENT | 0.0260 | 0.0003 | 0.0263 | 0.0048 | 0.0311 | 0.0260 | 0.00 | 8539.50 | 220.50 |
| G S1 APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0044 | 0.0308 | 0.0260 | 0.00 | 5942.33 | 202.67 |
| G S2 APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0044 | 0.0308 | 0.0260 | 0.00 | 5942.33 | 202.67 |
| M SW APARTMENT | 0.0519 | 0.0005 | 0.0524 | 0.0105 | 0.0629 | 0.0519 | 0.00 | 5938.33 | 206.67 |
| M NW APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0115 | 0.0638 | 0.0519 | 0.00 | 8535.00 | 225.00 |
| M SE APARTMENT | 0.0519 | 0.0005 | 0.0524 | 0.0105 | 0.0629 | 0.0519 | 0.00 | 5938.33 | 206.67 |
| M NE APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0115 | 0.0638 | 0.0519 | 0.00 | 8535.00 | 225.00 |
| M N1 APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0069 | 0.0592 | 0.0519 | 0.00 | 8535.00 | 225.00 |
| M N2 APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0069 | 0.0592 | 0.0519 | 0.00 | 8535.00 | 225.00 |
| M S1 APARTMENT | 0.0519 | 0.0005 | 0.0524 | 0.0064 | 0.0587 | 0.0519 | 0.00 | 5938.33 | 206.67 |
| M S2 APARTMENT | 0.0519 | 0.0005 | 0.0524 | 0.0064 | 0.0587 | 0.0519 | 0.00 | 5938.33 | 206.67 |
| T SW APARTMENT | 0.0260 | 0.0005 | 0.0265 | 0.0139 | 0.0404 | 0.0260 | 0.00 | 5933.00 | 212.00 |
| T NW APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0152 | 0.0416 | 0.0260 | 0.00 | 8528.67 | 231.33 |
| T SE APARTMENT | 0.0260 | 0.0005 | 0.0265 | 0.0139 | 0.0404 | 0.0260 | 0.00 | 5933.00 | 212.00 |
| T NE APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0152 | 0.0416 | 0.0260 | 0.00 | 8528.67 | 231.33 |
| T N1 APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0092 | 0.0356 | 0.0260 | 0.00 | 8528.67 | 231.33 |
| T N2 APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0092 | 0.0356 | 0.0260 | 0.00 | 8528.67 | 231.33 |
| T S1 APARTMENT | 0.0260 | 0.0005 | 0.0265 | 0.0084 | 0.0349 | 0.0260 | 0.00 | 5933.00 | 212.00 |
| T S2 APARTMENT | 0.0260 | 0.0005 | 0.0265 | 0.0084 | 0.0349 | 0.0260 | 0.00 | 5933.00 | 212.00 |
| Total Facility | 1.2580 | 0.0132 | 1.2712 | 0.2855 | 1.5567 | 1.2580 | 0.00 | 8760.00 | 231.33 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 9691.01 | 9691.01 | 818502.78 | 8759.00 | 0.17 | 0.83 | 17.83 |
| SPLIT GNW | 0.00 | 10205.80 | 10205.80 | 818502.78 | 8758.50 | 0.17 | 1.33 | 0.00 |
| SPLIT OFFICE | 1740849.09 | 0.00 | 1740849.09 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 10205.80 | 10205.80 | 818502.78 | 8758.50 | 0.17 | 1.33 | 0.00 |
| SPLIT GN1 | 0.00 | 10205.79 | 10205.79 | 818502.78 | 8758.50 | 0.17 | 1.33 | 0.00 |
| SPLIT GN2 | 0.00 | 10205.79 | 10205.79 | 818502.78 | 8758.50 | 0.17 | 1.33 | 0.00 |
| SPLIT GS1 | 0.00 | 9691.01 | 9691.01 | 818502.78 | 8759.00 | 0.17 | 0.83 | 17.83 |
| SPLIT GS2 | 0.00 | 9691.01 | 9691.01 | 818502.78 | 8759.00 | 0.17 | 0.83 | 17.83 |
| SPLIT MSW | 0.00 | 11193.26 | 11193.26 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 18.33 |
| SPLIT MNW | 0.00 | 12084.72 | 12084.72 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MSE | 0.00 | 11193.26 | 11193.26 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 18.33 |
| SPLIT MNE | 0.00 | 12084.72 | 12084.72 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MN1 | 0.00 | 12084.71 | 12084.71 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MN2 | 0.00 | 12084.71 | 12084.71 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MS1 | 0.00 | 11193.26 | 11193.26 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 18.33 |
| SPLIT MS2 | 0.00 | 11193.26 | 11193.26 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 18.33 |
| SPLIT TSW | 0.00 | 13176.48 | 13176.48 | 818502.78 | 8744.50 | 0.67 | 14.83 | 19.33 |
| SPLIT TNW | 0.00 | 14488.20 | 14488.20 | 818502.78 | 8736.50 | 0.67 | 22.83 | 0.00 |
| SPLIT TSE | 0.00 | 13177.76 | 13177.76 | 818502.78 | 8744.33 | 0.83 | 14.83 | 19.33 |
| SPLIT TNE | 0.00 | 14491.02 | 14491.02 | 818502.78 | 8736.33 | 0.83 | 22.83 | 0.00 |
| SPLIT TN1 | 0.00 | 14493.87 | 14493.87 | 818502.78 | 8736.17 | 0.75 | 23.08 | 0.00 |
| SPLIT TN2 | 0.00 | 14493.88 | 14493.88 | 818502.78 | 8736.17 | 0.75 | 23.08 | 0.00 |
| SPLIT TS1 | 0.00 | 13179.66 | 13179.66 | 818502.78 | 8744.33 | 0.50 | 15.17 | 19.33 |
| SPLIT TS2 | 0.00 | 13179.65 | 13179.65 | 818502.78 | 8744.33 | 0.50 | 15.17 | 19.33 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 6144.33 | 0.17 | 0.50 |
| SPLIT GNW | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8758.50 | 0.17 | 1.33 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0552 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8758.50 | 0.17 | 1.33 |
| SPLIT GN1 | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8758.50 | 0.17 | 1.33 |
| SPLIT GN2 | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8758.50 | 0.17 | 1.33 |
| SPLIT GS1 | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 6144.33 | 0.17 | 0.50 |
| SPLIT GS2 | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 6144.33 | 0.17 | 0.50 |
| SPLIT MSW | 0.0000 | 0.0005 | 0.0005 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MSE | 0.0000 | 0.0005 | 0.0005 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MN1 | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MN2 | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MS1 | 0.0000 | 0.0005 | 0.0005 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.0000 | 0.0005 | 0.0005 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6132.50 | 0.67 | 11.83 |
| SPLIT TNW | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 8736.50 | 0.67 | 22.83 |
| SPLIT TSE | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6132.33 | 0.83 | 11.83 |
| SPLIT TNE | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 8736.33 | 0.83 | 22.83 |
| SPLIT TN1 | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 8736.17 | 0.75 | 23.08 |
| SPLIT TN2 | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 8736.17 | 0.75 | 23.08 |
| SPLIT TS1 | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6132.33 | 0.50 | 12.17 |
| SPLIT TS2 | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6132.33 | 0.50 | 12.17 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 186.36 | 2234.27 | 21-DEC-06:10 | 9756.81 | 06-MAY-15:10 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| ElectricityPurchased:Plant | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| Cogeneration:ElectricityPurchased | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| General:Cogeneration:ElectricityPurchased | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| ElectricityNet:Plant | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| Cogeneration:ElectricityNet | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| General:Cogeneration:ElectricityNet | 1695.24 | 21406.78 | 21-DEC-05:00 | 107146.98 | 06-MAY-16:20 |
| Electricity:HVAC | 755.30 | 4428.57 | 21-DEC-06:10 | 47111.20 | 13-JUN-15:10 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 186.36 | 2234.27 | 21-DEC-06:10 | 9756.81 | 06-MAY-15:10 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 568.94 | 2194.30 | 21-DEC-06:10 | 37533.67 | 13-JUN-15:10 |
| General:Cooling:Electricity | 568.94 | 2194.30 | 21-DEC-06:10 | 37533.67 | 13-JUN-15:10 |
| ExteriorLights:Electricity | 50.10 | 0.00 | 01-JAN-06:20 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 50.10 | 0.00 | 01-JAN-06:20 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 331.96 | 1950.00 | 01-JAN-00:10 | 36755.48 | 16-JAN-07:10 |
| WaterSystems:Electricity | 331.96 | 1950.00 | 01-JAN-00:10 | 36755.48 | 16-JAN-07:10 |
| Water Heater:WaterSystems:Electricity | 331.96 | 1950.00 | 01-JAN-00:10 | 36755.48 | 16-JAN-07:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| NaturalGas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 3498.54 | 19961.52 | 21-DEC-06:10 | 211932.14 | 16-JUN-15:30 |
| EnergyTransfer:Building | 1248.01 | 11113.33 | 21-DEC-06:10 | 74405.92 | 06-MAY-15:10 |
| EnergyTransfer:Zone:G SW APARTMENT | 43.05 | 538.03 | 21-DEC-06:10 | 2528.93 | 19-MAR-15:40 |
| Heating:EnergyTransfer | 4.75 | 0.00 | 01-JAN-11:50 | 595.07 | 09-MAY-17:40 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer | 4.75 | 0.00 | 01-JAN-11:50 | 595.07 | 09-MAY-17:40 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer | 1243.27 | 11103.61 | 21-DEC-06:10 | 74405.92 | 06-MAY-15:10 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 43.05 | 538.03 | 21-DEC-06:10 | 2528.93 | 19-MAR-15:40 |
| General:Cooling:EnergyTransfer | 1243.27 | 11103.61 | 21-DEC-06:10 | 74405.92 | 06-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 43.05 | 538.03 | 21-DEC-06:10 | 2528.93 | 19-MAR-15:40 |
| EnergyTransfer:Zone:G NW APARTMENT | 41.32 | 439.35 | 21-DEC-06:10 | 2625.70 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 41.32 | 439.35 | 21-DEC-06:10 | 2625.70 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 41.32 | 439.35 | 21-DEC-06:10 | 2625.70 | 16-JUN-16:10 |
| EnergyTransfer:Zone:OFFICE | 32.69 | 0.16 | 26-FEB-22:20 | 4736.25 | 21-FEB-09:10 |
| Heating:EnergyTransfer:Zone:OFFICE | 4.75 | 0.00 | 01-JAN-11:50 | 595.07 | 09-MAY-17:40 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 4.75 | 0.00 | 01-JAN-11:50 | 595.07 | 09-MAY-17:40 |
| Cooling:EnergyTransfer:Zone:OFFICE | 27.94 | 0.00 | 01-JAN-00:10 | 4736.25 | 21-FEB-09:10 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 27.94 | 0.00 | 01-JAN-00:10 | 4736.25 | 21-FEB-09:10 |
| EnergyTransfer:Zone:G NE APARTMENT | 41.42 | 457.79 | 21-DEC-06:10 | 2382.53 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 41.42 | 457.79 | 21-DEC-06:10 | 2382.53 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 41.42 | 457.79 | 21-DEC-06:10 | 2382.53 | 16-JUN-16:10 |
| EnergyTransfer:Zone:G N1 APARTMENT | 34.24 | 463.23 | 21-DEC-06:10 | 1903.77 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 34.24 | 463.23 | 21-DEC-06:10 | 1903.77 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 34.24 | 463.23 | 21-DEC-06:10 | 1903.77 | 16-JUN-16:10 |
| EnergyTransfer:Zone:G N2 APARTMENT | 34.25 | 463.21 | 21-DEC-06:10 | 1900.57 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 34.25 | 463.21 | 21-DEC-06:10 | 1900.57 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 34.25 | 463.21 | 21-DEC-06:10 | 1900.57 | 16-JUN-16:10 |
| EnergyTransfer:Zone:G S1 APARTMENT | 36.16 | 571.58 | 21-DEC-06:10 | 1861.13 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 36.16 | 571.58 | 21-DEC-06:10 | 1861.13 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 36.16 | 571.58 | 21-DEC-06:10 | 1861.13 | 04-JAN-13:00 |
| EnergyTransfer:Zone:G S2 APARTMENT | 39.76 | 651.32 | 21-DEC-06:10 | 1966.93 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 39.76 | 651.32 | 21-DEC-06:10 | 1966.93 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 39.76 | 651.32 | 21-DEC-06:10 | 1966.93 | 04-JAN-13:00 |
| EnergyTransfer:Zone:M SW APARTMENT | 84.29 | 778.25 | 21-DEC-06:10 | 5667.34 | 19-MAR-15:30 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 84.29 | 778.25 | 21-DEC-06:10 | 5667.34 | 19-MAR-15:30 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 84.29 | 778.25 | 21-DEC-06:10 | 5667.34 | 19-MAR-15:30 |
| EnergyTransfer:Zone:M NW APARTMENT | 80.37 | 588.96 | 21-DEC-06:40 | 5651.61 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 80.37 | 588.96 | 21-DEC-06:40 | 5651.61 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 80.37 | 588.96 | 21-DEC-06:40 | 5651.61 | 16-JUN-16:10 |
| EnergyTransfer:Zone:M SE APARTMENT | 84.52 | 834.42 | 21-DEC-06:10 | 5067.78 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 84.52 | 834.42 | 21-DEC-06:10 | 5067.78 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 84.52 | 834.42 | 21-DEC-06:10 | 5067.78 | 04-JAN-13:00 |
| EnergyTransfer:Zone:M NE APARTMENT | 80.59 | 653.36 | 21-DEC-06:10 | 5016.45 | 06-MAY-15:10 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 80.59 | 653.36 | 21-DEC-06:10 | 5016.45 | 06-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 80.59 | 653.36 | 21-DEC-06:10 | 5016.45 | 06-MAY-15:10 |
| EnergyTransfer:Zone:M N1 APARTMENT | 65.85 | 736.19 | 21-DEC-06:40 | 3917.00 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 65.85 | 736.19 | 21-DEC-06:40 | 3917.00 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 65.85 | 736.19 | 21-DEC-06:40 | 3917.00 | 16-JUN-16:10 |
| EnergyTransfer:Zone:M N2 APARTMENT | 65.86 | 736.74 | 21-DEC-06:30 | 3909.45 | 16-JUN-16:10 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 65.86 | 736.74 | 21-DEC-06:30 | 3909.45 | 16-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 65.86 | 736.74 | 21-DEC-06:30 | 3909.45 | 16-JUN-16:10 |
| EnergyTransfer:Zone:M S1 APARTMENT | 69.81 | 930.16 | 21-DEC-06:10 | 4014.38 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 69.81 | 930.16 | 21-DEC-06:10 | 4014.38 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 69.81 | 930.16 | 21-DEC-06:10 | 4014.38 | 04-JAN-13:00 |
| EnergyTransfer:Zone:M S2 APARTMENT | 69.82 | 929.67 | 21-DEC-06:10 | 4022.63 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 69.82 | 929.67 | 21-DEC-06:10 | 4022.63 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 69.82 | 929.67 | 21-DEC-06:10 | 4022.63 | 04-JAN-13:00 |
| EnergyTransfer:Zone:T SW APARTMENT | 47.90 | 102.30 | 21-JAN-06:10 | 3974.30 | 19-MAR-15:30 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 47.90 | 102.30 | 21-JAN-06:10 | 3974.30 | 19-MAR-15:30 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 47.90 | 102.30 | 21-JAN-06:10 | 3974.30 | 19-MAR-15:30 |
| EnergyTransfer:Zone:T NW APARTMENT | 45.79 | 96.73 | 21-JAN-06:30 | 3911.46 | 06-MAY-15:10 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 45.79 | 96.73 | 21-JAN-06:30 | 3911.46 | 06-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 45.79 | 96.73 | 21-JAN-06:30 | 3911.46 | 06-MAY-15:10 |
| EnergyTransfer:Zone:T SE APARTMENT | 48.04 | 102.10 | 21-JAN-06:10 | 3509.99 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 48.04 | 102.10 | 21-JAN-06:10 | 3509.99 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 48.04 | 102.10 | 21-JAN-06:10 | 3509.99 | 04-JAN-13:00 |
| EnergyTransfer:Zone:T NE APARTMENT | 45.92 | 97.15 | 21-JAN-06:20 | 3494.47 | 06-MAY-15:10 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 45.92 | 97.15 | 21-JAN-06:20 | 3494.47 | 06-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 45.92 | 97.15 | 21-JAN-06:20 | 3494.47 | 06-MAY-15:10 |
| EnergyTransfer:Zone:T N1 APARTMENT | 38.02 | 117.32 | 21-DEC-07:30 | 2728.37 | 06-MAY-15:10 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 38.02 | 117.32 | 21-DEC-07:30 | 2728.37 | 06-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 38.02 | 117.32 | 21-DEC-07:30 | 2728.37 | 06-MAY-15:10 |
| EnergyTransfer:Zone:T N2 APARTMENT | 38.03 | 117.51 | 21-DEC-07:30 | 2722.75 | 06-MAY-15:10 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 38.03 | 117.51 | 21-DEC-07:30 | 2722.75 | 06-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 38.03 | 117.51 | 21-DEC-07:30 | 2722.75 | 06-MAY-15:10 |
| EnergyTransfer:Zone:T S1 APARTMENT | 40.16 | 141.01 | 23-JAN-06:20 | 2859.06 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 40.16 | 141.01 | 23-JAN-06:20 | 2859.06 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 40.16 | 141.01 | 23-JAN-06:20 | 2859.06 | 04-JAN-13:00 |
| EnergyTransfer:Zone:T S2 APARTMENT | 40.17 | 140.96 | 23-JAN-06:20 | 2866.70 | 04-JAN-13:00 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 40.17 | 140.96 | 23-JAN-06:20 | 2866.70 | 04-JAN-13:00 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 40.17 | 140.96 | 23-JAN-06:20 | 2866.70 | 04-JAN-13:00 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 2250.53 | 8848.19 | 21-DEC-06:10 | 137628.26 | 16-JUN-15:30 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 26-FEB-04:50 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 20-MAY-21:50 |
| HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| CoolingCoils:EnergyTransfer | 2250.53 | 8848.19 | 21-DEC-06:10 | 137628.26 | 16-JUN-15:30 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 4.329 | -0.068 | 0.000 | -47.308 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 10.741 | 0.000 | 1.402 | 14.204 | 0.000 | -0.487 | 0.000 | -0.042 | 0.000 |
| G NW APARTMENT | 4.330 | -0.068 | 0.000 | -45.579 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 9.411 | 0.000 | 1.402 | 13.759 | 0.000 | -0.488 | 0.000 | -0.043 | 0.000 |
| OFFICE | 0.000 | 0.000 | 4.746 | -27.940 | 0.000 | 0.000 | 1.959 | 7.396 | 9.469 | 9.586 | 0.000 | 0.728 | 0.000 | 0.000 | -1.687 | 0.000 | -0.435 | -3.821 |
| G NE APARTMENT | 4.329 | -0.068 | 0.000 | -45.682 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 9.406 | 0.000 | 1.402 | 13.849 | 0.000 | -0.469 | 0.000 | -0.043 | 0.000 |
| G N1 APARTMENT | 4.331 | -0.068 | 0.000 | -38.504 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 4.817 | 0.000 | 0.846 | 11.612 | 0.000 | -0.275 | 0.000 | -0.034 | 0.000 |
| G N2 APARTMENT | 4.331 | -0.068 | 0.000 | -38.510 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 4.817 | 0.000 | 0.846 | 11.618 | 0.000 | -0.275 | 0.000 | -0.034 | 0.000 |
| G S1 APARTMENT | 4.330 | -0.068 | 0.000 | -40.422 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 6.161 | 0.000 | 0.846 | 12.232 | 0.000 | -0.274 | 0.000 | -0.034 | 0.000 |
| G S2 APARTMENT | 4.329 | -0.068 | 0.000 | -44.016 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 6.122 | 0.000 | 0.846 | 15.886 | 0.000 | -0.293 | 0.000 | -0.034 | 0.000 |
| M SW APARTMENT | 8.662 | -0.135 | 0.000 | -92.812 | 0.000 | 0.000 | 7.122 | 2.908 | 24.426 | 21.697 | 0.000 | 4.014 | 25.071 | 0.000 | -0.843 | 0.000 | -0.109 | 0.000 |
| M NW APARTMENT | 8.663 | -0.135 | 0.000 | -88.894 | 0.000 | 0.000 | 7.216 | 2.908 | 24.426 | 19.038 | 0.000 | 4.014 | 23.726 | 0.000 | -0.849 | 0.000 | -0.112 | 0.000 |
| M SE APARTMENT | 8.661 | -0.135 | 0.000 | -93.041 | 0.000 | 0.000 | 7.122 | 2.908 | 24.426 | 21.711 | 0.000 | 4.014 | 25.270 | 0.000 | -0.826 | 0.000 | -0.109 | 0.000 |
| M NE APARTMENT | 8.662 | -0.135 | 0.000 | -89.121 | 0.000 | 0.000 | 7.216 | 2.908 | 24.426 | 19.034 | 0.000 | 4.014 | 23.923 | 0.000 | -0.814 | 0.000 | -0.112 | 0.000 |
| M N1 APARTMENT | 8.665 | -0.135 | 0.000 | -74.382 | 0.000 | 0.000 | 7.216 | 2.908 | 24.426 | 9.751 | 0.000 | 2.421 | 19.705 | 0.000 | -0.488 | 0.000 | -0.086 | 0.000 |
| M N2 APARTMENT | 8.665 | -0.135 | 0.000 | -74.394 | 0.000 | 0.000 | 7.216 | 2.908 | 24.426 | 9.750 | 0.000 | 2.421 | 19.717 | 0.000 | -0.488 | 0.000 | -0.086 | 0.000 |
| M S1 APARTMENT | 8.664 | -0.135 | 0.000 | -78.334 | 0.000 | 0.000 | 7.122 | 2.908 | 24.426 | 12.440 | 0.000 | 2.421 | 21.054 | 0.000 | -0.481 | 0.000 | -0.084 | 0.000 |
| M S2 APARTMENT | 8.664 | -0.135 | 0.000 | -78.346 | 0.000 | 0.000 | 7.122 | 2.908 | 24.426 | 12.440 | 0.000 | 2.421 | 21.066 | 0.000 | -0.481 | 0.000 | -0.084 | 0.000 |
| T SW APARTMENT | 4.330 | -0.068 | 0.000 | -52.165 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 10.571 | 0.000 | 2.633 | 17.952 | 0.000 | -0.412 | 0.000 | -0.070 | 0.000 |
| T NW APARTMENT | 4.331 | -0.068 | 0.000 | -50.054 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 9.254 | 0.000 | 2.633 | 17.118 | 0.000 | -0.417 | 0.000 | -0.072 | 0.000 |
| T SE APARTMENT | 4.330 | -0.068 | 0.000 | -52.300 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 10.575 | 0.000 | 2.633 | 18.073 | 0.000 | -0.401 | 0.000 | -0.070 | 0.000 |
| T NE APARTMENT | 4.330 | -0.068 | 0.000 | -50.187 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 9.251 | 0.000 | 2.633 | 17.236 | 0.000 | -0.398 | 0.000 | -0.072 | 0.000 |
| T N1 APARTMENT | 4.331 | -0.068 | 0.000 | -42.284 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 4.736 | 0.000 | 1.588 | 14.720 | 0.000 | -0.245 | 0.000 | -0.054 | 0.000 |
| T N2 APARTMENT | 4.331 | -0.068 | 0.000 | -42.293 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 4.736 | 0.000 | 1.588 | 14.730 | 0.000 | -0.245 | 0.000 | -0.054 | 0.000 |
| T S1 APARTMENT | 4.331 | -0.068 | 0.000 | -44.422 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 6.072 | 0.000 | 1.588 | 15.563 | 0.000 | -0.240 | 0.000 | -0.052 | 0.000 |
| T S2 APARTMENT | 4.330 | -0.068 | 0.000 | -44.431 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 6.072 | 0.000 | 1.588 | 15.572 | 0.000 | -0.239 | 0.000 | -0.052 | 0.000 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.094 | 11.688 | 0.000 | 1.026 | 0.000 | 0.219 | 0.000 | 0.000 | -0.080 | 0.000 | -0.039 | -17.908 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.736 | 11.688 | 3.530 | 2.977 | 0.000 | 4.071 | 0.000 | 0.000 | -0.319 | 0.000 | -1.531 | -25.153 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.342 | 23.376 | 0.000 | 2.098 | 0.000 | 0.393 | 0.000 | 0.000 | -0.155 | 0.000 | -0.057 | -35.998 |
| Total Facility | 134.260 | -2.099 | 4.746 | -1375.421 | 0.000 | 0.000 | 133.273 | 99.229 | 391.594 | 254.293 | 0.000 | 55.621 | 403.657 | 0.000 | -12.668 | 0.000 | -3.605 | -82.879 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 19-MAR-15:40 | 0.00 | 365.32 | 0.00 | -2894.68 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 1276.31 | 0.00 | 334.71 | 219.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 16-JUN-16:03 | 0.00 | 313.72 | 0.00 | -2939.54 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 1293.68 | 0.00 | 267.68 | 302.09 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 23-JAN-08:62 | 0.00 | 0.00 | 0.00 | -5990.00 | 0.00 | 0.00 | 233.74 | 582.92 | 588.62 | 783.80 | 0.00 | 0.00 | 3841.06 | 0.00 | -0.00 | 0.00 | -40.13 | 0.00 |
| G NE APARTMENT | 16-JUN-16:03 | 0.00 | 313.79 | 0.00 | -2696.46 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 714.93 | 0.00 | 267.68 | 637.68 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 16-JUN-16:03 | 0.00 | 313.80 | 0.00 | -2217.71 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 540.60 | 0.00 | 161.46 | 439.48 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 16-JUN-16:03 | 0.00 | 313.80 | 0.00 | -2214.51 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 540.63 | 0.00 | 161.46 | 436.24 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 04-JAN-13:00 | 0.00 | 342.66 | 0.00 | -2203.71 | 0.00 | 0.00 | 0.00 | 17.36 | 406.15 | 1103.49 | 0.00 | 113.94 | 220.11 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 04-JAN-13:00 | 0.00 | 342.62 | 0.00 | -2309.47 | 0.00 | 0.00 | 0.00 | 17.36 | 406.15 | 1101.95 | 0.00 | 113.94 | 327.44 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 19-MAR-15:30 | 0.00 | 733.93 | 0.00 | -6402.25 | 0.00 | 0.00 | 334.45 | 121.52 | 941.80 | 2778.03 | 0.00 | 925.89 | 566.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 16-JUN-16:10 | 0.00 | 627.70 | 0.00 | -6281.18 | 0.00 | 0.00 | 173.92 | 173.60 | 1177.25 | 2590.05 | 0.00 | 767.68 | 771.00 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 04-JAN-13:00 | 0.00 | 685.32 | 0.00 | -5752.97 | 0.00 | 0.00 | 0.00 | 34.72 | 812.30 | 2720.80 | 0.00 | 541.87 | 957.96 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 06-MAY-15:10 | 0.00 | 850.66 | 0.00 | -5867.48 | 0.00 | 0.00 | 100.34 | 121.52 | 941.80 | 1605.92 | 0.00 | 917.56 | 1329.70 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 16-JUN-16:10 | 0.00 | 627.89 | 0.00 | -4546.80 | 0.00 | 0.00 | 173.92 | 173.60 | 1177.25 | 1085.12 | 0.00 | 463.04 | 845.98 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 16-JUN-16:10 | 0.00 | 627.89 | 0.00 | -4539.24 | 0.00 | 0.00 | 173.92 | 173.60 | 1177.25 | 1085.19 | 0.00 | 463.04 | 838.36 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 04-JAN-13:00 | 0.00 | 685.41 | 0.00 | -4699.61 | 0.00 | 0.00 | 0.00 | 34.72 | 812.30 | 2203.58 | 0.00 | 326.84 | 636.76 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 04-JAN-13:00 | 0.00 | 685.41 | 0.00 | -4707.86 | 0.00 | 0.00 | 0.00 | 34.72 | 812.30 | 2203.48 | 0.00 | 326.84 | 645.11 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 19-MAR-15:30 | 0.00 | 366.83 | 0.00 | -4341.83 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 1356.97 | 0.00 | 610.13 | 1309.02 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 06-MAY-15:10 | 0.00 | 424.95 | 0.00 | -4336.59 | 0.00 | 0.00 | 50.16 | 60.76 | 470.90 | 1366.25 | 0.00 | 604.85 | 1358.72 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 04-JAN-13:00 | 0.00 | 342.52 | 0.00 | -3852.44 | 0.00 | 0.00 | 0.00 | 17.36 | 406.15 | 1328.79 | 0.00 | 356.98 | 1400.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 06-MAY-15:10 | 0.00 | 425.04 | 0.00 | -3919.80 | 0.00 | 0.00 | 50.16 | 60.76 | 470.90 | 777.36 | 0.00 | 604.86 | 1530.73 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 06-MAY-15:10 | 0.00 | 425.09 | 0.00 | -3153.62 | 0.00 | 0.00 | 50.17 | 60.76 | 470.90 | 523.69 | 0.00 | 364.90 | 1258.13 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 06-MAY-15:10 | 0.00 | 425.09 | 0.00 | -3148.02 | 0.00 | 0.00 | 50.17 | 60.76 | 470.90 | 523.75 | 0.00 | 364.90 | 1252.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 04-JAN-13:00 | 0.00 | 342.56 | 0.00 | -3201.51 | 0.00 | 0.00 | 0.00 | 17.36 | 406.15 | 1083.67 | 0.00 | 215.32 | 1136.45 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 04-JAN-13:00 | 0.00 | 342.56 | 0.00 | -3209.15 | 0.00 | 0.00 | 0.00 | 17.36 | 406.15 | 1083.57 | 0.00 | 215.32 | 1144.19 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 06-MAY-15:10 | 0.00 | 13183.08 | 0.00 | -87594.48 | 0.00 | 0.00 | 3562.95 | 3482.59 | 14940.40 | 24333.87 | 0.00 | 12559.92 | 15531.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 05-MAY-16:01 | 0.00 | 0.00 | 722.17 | 0.00 | 0.00 | 0.00 | 0.00 | 116.58 | 294.31 | 495.11 | 0.00 | 243.77 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1871.95 |
| G NE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 05-MAY-16:01 | -71218.65 | 82922.51 | 722.17 | -82922.51 | 0.00 | 0.00 | 1832.46 | 4289.87 | 18750.02 | 20426.80 | 0.00 | 13139.19 | 12058.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3396 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3396 | 0.0764 | 1.0000 | Not calculated | 0.0260 | 0.0764 | ||
| SPLIT GNW | 0.3415 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3415 | 0.0760 | 1.0000 | Not calculated | 0.0260 | 0.0760 | ||
| SPLIT OFFICE | 0.3875 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3875 | 0.0983 | 1.0000 | Not calculated | 0.0381 | 0.0983 | ||
| SPLIT GNE | 0.3251 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3251 | 0.0798 | 1.0000 | Not calculated | 0.0260 | 0.0798 | ||
| SPLIT GN1 | 0.2929 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2929 | 0.0886 | 1.0000 | Not calculated | 0.0260 | 0.0886 | ||
| SPLIT GN2 | 0.2925 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2925 | 0.0887 | 1.0000 | Not calculated | 0.0260 | 0.0887 | ||
| SPLIT GS1 | 0.2912 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2912 | 0.0891 | 1.0000 | Not calculated | 0.0260 | 0.0891 | ||
| SPLIT GS2 | 0.2934 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2934 | 0.0885 | 1.0000 | Not calculated | 0.0260 | 0.0885 | ||
| SPLIT MSW | 0.7570 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7570 | 0.0686 | 1.0000 | Not calculated | 0.0519 | 0.0686 | ||
| SPLIT MNW | 0.7609 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7609 | 0.0682 | 1.0000 | Not calculated | 0.0519 | 0.0682 | ||
| SPLIT MSE | 0.7157 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7157 | 0.0725 | 1.0000 | Not calculated | 0.0519 | 0.0725 | ||
| SPLIT MNE | 0.7197 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7197 | 0.0721 | 1.0000 | Not calculated | 0.0519 | 0.0721 | ||
| SPLIT MN1 | 0.6477 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6477 | 0.0801 | 1.0000 | Not calculated | 0.0519 | 0.0801 | ||
| SPLIT MN2 | 0.6468 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6468 | 0.0802 | 1.0000 | Not calculated | 0.0519 | 0.0802 | ||
| SPLIT MS1 | 0.6440 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6440 | 0.0806 | 1.0000 | Not calculated | 0.0519 | 0.0806 | ||
| SPLIT MS2 | 0.6431 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6431 | 0.0807 | 1.0000 | Not calculated | 0.0519 | 0.0807 | ||
| SPLIT TSW | 0.4132 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4132 | 0.0628 | 1.0000 | Not calculated | 0.0260 | 0.0628 | ||
| SPLIT TNW | 0.4179 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4179 | 0.0621 | 1.0000 | Not calculated | 0.0260 | 0.0621 | ||
| SPLIT TSE | 0.3818 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3818 | 0.0680 | 1.0000 | Not calculated | 0.0260 | 0.0680 | ||
| SPLIT TNE | 0.3865 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3865 | 0.0672 | 1.0000 | Not calculated | 0.0260 | 0.0672 | ||
| SPLIT TN1 | 0.3579 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3579 | 0.0725 | 1.0000 | Not calculated | 0.0260 | 0.0725 | ||
| SPLIT TN2 | 0.3567 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3567 | 0.0728 | 1.0000 | Not calculated | 0.0260 | 0.0728 | ||
| SPLIT TS1 | 0.3532 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3532 | 0.0735 | 1.0000 | Not calculated | 0.0260 | 0.0735 | ||
| SPLIT TS2 | 0.3520 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3520 | 0.0737 | 1.0000 | Not calculated | 0.0260 | 0.0737 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3396 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3396 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0764 | ||
| SPLIT GNW | 0.3415 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3415 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0760 | ||
| SPLIT OFFICE | 0.3875 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3875 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0983 | ||
| SPLIT GNE | 0.3251 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3251 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0798 | ||
| SPLIT GN1 | 0.2929 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2929 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0886 | ||
| SPLIT GN2 | 0.2925 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2925 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0887 | ||
| SPLIT GS1 | 0.2912 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2912 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0891 | ||
| SPLIT GS2 | 0.2934 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2934 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0885 | ||
| SPLIT MSW | 0.7570 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7570 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0686 | ||
| SPLIT MNW | 0.7609 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7609 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0682 | ||
| SPLIT MSE | 0.7157 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7157 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0725 | ||
| SPLIT MNE | 0.7197 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7197 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0721 | ||
| SPLIT MN1 | 0.6477 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6477 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0801 | ||
| SPLIT MN2 | 0.6468 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6468 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0802 | ||
| SPLIT MS1 | 0.6440 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6440 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0806 | ||
| SPLIT MS2 | 0.6431 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6431 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0807 | ||
| SPLIT TSW | 0.4132 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4132 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0628 | ||
| SPLIT TNW | 0.4179 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4179 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0621 | ||
| SPLIT TSE | 0.3818 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3818 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0680 | ||
| SPLIT TNE | 0.3865 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3865 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0672 | ||
| SPLIT TN1 | 0.3579 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3579 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0725 | ||
| SPLIT TN2 | 0.3567 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3567 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0728 | ||
| SPLIT TS1 | 0.3532 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3532 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0735 | ||
| SPLIT TS2 | 0.3520 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3520 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0737 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3396 | 0.3396 | 0.3396 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3415 | 0.3415 | 0.3415 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3875 | 0.3875 | 0.3875 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3251 | 0.3251 | 0.3251 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2929 | 0.2929 | 0.2929 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2925 | 0.2925 | 0.2925 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2912 | 0.2912 | 0.2912 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2934 | 0.2934 | 0.2934 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7570 | 0.7570 | 0.7570 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7609 | 0.7609 | 0.7609 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7157 | 0.7157 | 0.7157 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7197 | 0.7197 | 0.7197 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6477 | 0.6477 | 0.6477 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6468 | 0.6468 | 0.6468 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6440 | 0.6440 | 0.6440 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6431 | 0.6431 | 0.6431 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4132 | 0.4132 | 0.4132 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4179 | 0.4179 | 0.4179 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3818 | 0.3818 | 0.3818 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3865 | 0.3865 | 0.3865 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3579 | 0.3579 | 0.3579 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3567 | 0.3567 | 0.3567 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3532 | 0.3532 | 0.3532 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3520 | 0.3520 | 0.3520 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3396 | 0.3396 | 0.3396 | 0.3396 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3415 | 0.3415 | 0.3415 | 0.3415 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3875 | 0.3875 | 0.3875 | 0.3875 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3251 | 0.3251 | 0.3251 | 0.3251 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2929 | 0.2929 | 0.2929 | 0.2929 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2925 | 0.2925 | 0.2925 | 0.2925 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2912 | 0.2912 | 0.2912 | 0.2912 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2934 | 0.2934 | 0.2934 | 0.2934 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.7570 | 0.7570 | 0.7570 | 0.7570 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.7609 | 0.7609 | 0.7609 | 0.7609 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7157 | 0.7157 | 0.7157 | 0.7157 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7197 | 0.7197 | 0.7197 | 0.7197 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6477 | 0.6477 | 0.6477 | 0.6477 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6468 | 0.6468 | 0.6468 | 0.6468 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6440 | 0.6440 | 0.6440 | 0.6440 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6431 | 0.6431 | 0.6431 | 0.6431 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4132 | 0.4132 | 0.4132 | 0.4132 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4179 | 0.4179 | 0.4179 | 0.4179 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3818 | 0.3818 | 0.3818 | 0.3818 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3865 | 0.3865 | 0.3865 | 0.3865 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3579 | 0.3579 | 0.3579 | 0.3579 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3567 | 0.3567 | 0.3567 | 0.3567 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3532 | 0.3532 | 0.3532 | 0.3532 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3520 | 0.3520 | 0.3520 | 0.3520 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3396 | 0.3396 | 0.3396 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3415 | 0.3415 | 0.3415 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3875 | 0.3875 | 0.3875 | No | 0.0381 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3251 | 0.3251 | 0.3251 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2929 | 0.2929 | 0.2929 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2925 | 0.2925 | 0.2925 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2912 | 0.2912 | 0.2912 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2934 | 0.2934 | 0.2934 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7570 | 0.7570 | 0.7570 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7609 | 0.7609 | 0.7609 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7157 | 0.7157 | 0.7157 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7197 | 0.7197 | 0.7197 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6477 | 0.6477 | 0.6477 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6468 | 0.6468 | 0.6468 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6440 | 0.6440 | 0.6440 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6431 | 0.6431 | 0.6431 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4132 | 0.4132 | 0.4132 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4179 | 0.4179 | 0.4179 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3818 | 0.3818 | 0.3818 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3865 | 0.3865 | 0.3865 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3579 | 0.3579 | 0.3579 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3567 | 0.3567 | 0.3567 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3532 | 0.3532 | 0.3532 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3520 | 0.3520 | 0.3520 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3396 | 0.3396 | 0.3396 | 0.3396 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3415 | 0.3415 | 0.3415 | 0.3415 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3875 | 0.3875 | 0.3875 | 0.3875 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3251 | 0.3251 | 0.3251 | 0.3251 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2929 | 0.2929 | 0.2929 | 0.2929 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2925 | 0.2925 | 0.2925 | 0.2925 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2912 | 0.2912 | 0.2912 | 0.2912 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2934 | 0.2934 | 0.2934 | 0.2934 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.7570 | 0.7570 | 0.7570 | 0.7570 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.7609 | 0.7609 | 0.7609 | 0.7609 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7157 | 0.7157 | 0.7157 | 0.7157 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7197 | 0.7197 | 0.7197 | 0.7197 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6477 | 0.6477 | 0.6477 | 0.6477 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6468 | 0.6468 | 0.6468 | 0.6468 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6440 | 0.6440 | 0.6440 | 0.6440 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6431 | 0.6431 | 0.6431 | 0.6431 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4132 | 0.4132 | 0.4132 | 0.4132 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4179 | 0.4179 | 0.4179 | 0.4179 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3818 | 0.3818 | 0.3818 | 0.3818 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3865 | 0.3865 | 0.3865 | 0.3865 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3579 | 0.3579 | 0.3579 | 0.3579 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3567 | 0.3567 | 0.3567 | 0.3567 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3532 | 0.3532 | 0.3532 | 0.3532 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3520 | 0.3520 | 0.3520 | 0.3520 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
| Total gross floor area [m2] | 3134.61 |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 11.00 |
| Number of hours not met | 11.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 568.94 | 37533.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 50.10 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 186.36 | 9756.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 331.96 | 36755.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1695.24 |
| Natural Gas | 0.00 | 0.00 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1695.24 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 181.50 |
| Fans (All) | 59.45 |
| Service Water Heating | 105.90 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 540.81 |
| Subtotal | 540.81 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 0.00 |
| Subtotal | 0.00 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 5.85 |
| Space Heating | 0.00 |
| Space Cooling | 33.56 |
| Fans (All) | 10.99 |
| Service Water Heating | 19.58 |
| Receptacle Equipment | 27.06 |
| Miscellaneous | 2.96 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 2316.83 | 3121.67 | 3321.50 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 138.67 | 6972.50 | 1648.83 | 0.00 | 0.00 |
| G CORRIDOR | 157.50 | 5410.83 | 3191.67 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 8760.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 8760.00 | 3321.50 | 0.00 | 0.00 |
| Average | 7559.00 | 898.70 | 302.30 | 0.00 | 0.00 |
| Sum | 204093.00 | 24265.00 | 8162.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6926.00 | 74.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 501.67 | 19339.50 | 3153.83 | 0.00 | 0.00 |
| G CORRIDOR | 420.50 | 13539.50 | 9035.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 22995.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 11830.00 | 22995.00 | 9035.00 | 0.00 | 0.00 |
| Average | 9814.75 | 2072.15 | 451.44 | 0.00 | 0.00 |
| Sum | 264998.17 | 55948.00 | 12188.83 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 3807.67 | 4952.33 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 3545.50 | 5214.50 | 0.00 | 0.00 | 0.00 |
| OFFICE | 1893.50 | 5200.33 | 1666.17 | 0.00 | 0.00 |
| G NE APARTMENT | 3682.67 | 5077.33 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 3041.50 | 5718.50 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 3044.33 | 5715.67 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 3485.50 | 5274.50 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 4163.00 | 4597.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 3007.67 | 5752.33 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 2716.33 | 6043.67 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 3139.00 | 5621.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 2836.83 | 5923.17 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 2426.33 | 6333.67 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 2431.00 | 6329.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 2803.83 | 5956.17 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 2805.83 | 5954.17 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 3101.17 | 5658.83 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 2958.17 | 5801.83 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 3245.17 | 5514.83 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 3097.50 | 5662.50 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 2811.67 | 5948.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 2815.50 | 5944.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 3000.17 | 5759.83 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 3004.50 | 5755.50 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 4378.83 | 4381.17 | 0.00 | 0.00 |
| G CORRIDOR | 0.67 | 4704.17 | 4055.00 | 0.17 | 0.00 |
| M CORRIDOR | 0.00 | 6199.33 | 2560.67 | 0.00 | 0.00 |
| Min | 0.00 | 4378.83 | 0.00 | 0.00 | 0.00 |
| Max | 4163.00 | 6333.67 | 4381.17 | 0.17 | 0.00 |
| Average | 2698.70 | 5592.29 | 469.00 | 0.01 | 0.00 |
| Sum | 72865.00 | 150991.83 | 12663.00 | 0.17 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 4292.83 | 7537.17 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 3241.83 | 7343.17 | 0.00 | 0.00 | 0.00 |
| OFFICE | 5571.33 | 1428.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 3098.67 | 7486.33 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 2695.50 | 7889.50 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 2693.50 | 7891.50 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 3922.83 | 7907.17 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 4916.33 | 6913.67 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 3161.33 | 8668.67 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 2253.33 | 8331.67 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 3124.17 | 8705.83 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 2071.17 | 8513.83 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 2013.17 | 8571.83 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 2009.00 | 8576.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 2984.50 | 8845.50 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 2982.83 | 8847.17 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 2853.00 | 8977.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 2129.00 | 8456.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 2798.00 | 9032.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 1875.00 | 8710.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 1983.50 | 8601.50 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 1973.00 | 8612.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 2784.67 | 9045.33 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 2777.17 | 9052.83 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 12991.50 | 10003.50 | 0.00 | 0.00 |
| G CORRIDOR | 2.00 | 10633.50 | 12359.17 | 0.33 | 0.00 |
| M CORRIDOR | 0.00 | 17701.33 | 5293.67 | 0.00 | 0.00 |
| Min | 0.00 | 1428.67 | 0.00 | 0.00 | 0.00 |
| Max | 5571.33 | 17701.33 | 12359.17 | 0.33 | 0.00 |
| Average | 2600.28 | 8713.73 | 1024.31 | 0.01 | 0.00 |
| Sum | 70207.67 | 235270.67 | 27656.33 | 0.33 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:34
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.374367E+10 | 2398.67 | 31-JAN-16:10 | 31.92 | 22.88 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 31.92 | 22.88 |
| February | 0.350960E+10 | 2372.26 | 28-FEB-15:20 | 34.20 | 24.48 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 34.20 | 24.48 |
| March | 0.380487E+10 | 2528.93 | 19-MAR-15:40 | 34.80 | 24.95 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.80 | 24.95 |
| April | 0.361319E+10 | 2304.87 | 02-APR-16:02 | 33.25 | 27.16 | 0.123963E+09 | 70.27 | 01-APR-02:39 | 33.25 | 27.16 |
| May | 0.372476E+10 | 2408.78 | 06-MAY-15:20 | 36.30 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.368128E+10 | 2288.77 | 16-JUN-16:03 | 33.17 | 26.74 | 0.120421E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.349117E+10 | 2100.16 | 04-JUL-16:07 | 31.17 | 25.29 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 23.00 | 22.27 |
| August | 0.347041E+10 | 2158.04 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.343078E+10 | 2138.44 | 10-SEP-15:10 | 31.33 | 26.68 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.342159E+10 | 2197.99 | 28-OCT-16:10 | 29.58 | 26.02 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 29.58 | 26.02 |
| November | 0.348992E+10 | 2242.63 | 19-NOV-14:30 | 31.75 | 24.87 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.366486E+10 | 2304.26 | 07-DEC-15:30 | 31.90 | 22.76 | 0.129276E+09 | 70.30 | 07-DEC-01:10 | 31.90 | 22.76 |
| Annual Sum or Average | 0.430461E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.342159E+10 | 2100.16 | 29.58 | 22.76 | 0.115109E+09 | 70.27 | 23.00 | 20.24 | ||
| Maximum of Months | 0.380487E+10 | 2528.93 | 36.30 | 27.35 | 0.129276E+09 | 70.30 | 34.80 | 27.16 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.309709E+10 | 1882.37 | 31-JAN-16:10 | 31.92 | 22.88 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 31.92 | 22.88 |
| February | 0.302795E+10 | 2025.99 | 28-FEB-16:10 | 32.33 | 23.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 32.33 | 23.66 |
| March | 0.357908E+10 | 2297.46 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.365699E+10 | 2232.79 | 11-APR-16:10 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-03:09 | 34.33 | 26.63 |
| May | 0.394212E+10 | 2560.32 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.405973E+10 | 2625.87 | 16-JUN-16:03 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.371863E+10 | 2300.23 | 14-JUL-17:17 | 32.57 | 25.09 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.360078E+10 | 2235.67 | 01-AUG-16:40 | 32.23 | 27.12 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.338542E+10 | 2109.76 | 02-SEP-16:50 | 32.42 | 26.82 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.319165E+10 | 2034.22 | 04-OCT-16:17 | 31.17 | 25.88 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.304141E+10 | 1873.85 | 04-NOV-16:10 | 29.60 | 24.92 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.301593E+10 | 1744.31 | 07-DEC-16:10 | 30.50 | 22.94 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 30.50 | 22.94 |
| Annual Sum or Average | 0.413168E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.301593E+10 | 1744.31 | 29.60 | 22.88 | 0.116313E+09 | 70.27 | 23.38 | 21.12 | ||
| Maximum of Months | 0.405973E+10 | 2625.87 | 36.65 | 27.35 | 0.128775E+09 | 70.30 | 34.33 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.236976E+10 | 5990.77 | 23-JAN-08:62 | 21.83 | 18.43 | 70709438.00 | 217.49 | 25-JAN-08:09 | 21.42 | 18.65 |
| February | 0.230147E+10 | 5682.63 | 24-FEB-08:62 | 23.33 | 18.56 | 67173553.22 | 217.47 | 06-FEB-08:09 | 23.33 | 18.56 |
| March | 0.260152E+10 | 5256.43 | 03-MAR-08:62 | 26.17 | 20.16 | 81317796.38 | 217.47 | 10-MAR-08:09 | 27.33 | 22.87 |
| April | 0.226970E+10 | 4502.96 | 03-APR-08:62 | 28.67 | 25.83 | 70722542.29 | 217.47 | 18-APR-07:10 | 27.92 | 25.99 |
| May | 0.247810E+10 | 4427.22 | 30-MAY-08:20 | 30.33 | 27.56 | 77840823.45 | 217.47 | 26-MAY-07:10 | 30.33 | 27.56 |
| June | 0.250522E+10 | 4389.43 | 12-JUN-08:50 | 30.83 | 27.85 | 77845567.90 | 217.47 | 23-JUN-07:10 | 27.67 | 26.41 |
| July | 0.212844E+10 | 4743.68 | 17-JUL-08:62 | 25.75 | 23.75 | 70706443.08 | 217.47 | 24-JUL-07:10 | 25.25 | 24.10 |
| August | 0.241453E+10 | 4395.49 | 28-AUG-08:63 | 30.17 | 26.99 | 81338261.00 | 217.47 | 25-AUG-07:10 | 30.17 | 26.99 |
| September | 0.217085E+10 | 4433.84 | 05-SEP-08:63 | 28.33 | 26.59 | 70721086.30 | 217.47 | 01-SEP-07:10 | 28.33 | 26.59 |
| October | 0.220969E+10 | 4662.31 | 10-OCT-08:62 | 25.33 | 24.07 | 74246599.39 | 217.47 | 20-OCT-07:10 | 26.33 | 24.65 |
| November | 0.223901E+10 | 5158.08 | 24-NOV-09:02 | 26.80 | 21.69 | 70714092.57 | 217.47 | 09-NOV-08:09 | 26.80 | 21.69 |
| December | 0.225470E+10 | 5611.10 | 21-DEC-08:62 | 21.33 | 19.10 | 70706314.55 | 217.48 | 29-DEC-08:09 | 24.50 | 22.78 |
| Annual Sum or Average | 0.279430E+11 | 0.884043E+09 | ||||||||
| Minimum of Months | 0.212844E+10 | 4389.43 | 21.33 | 18.43 | 67173553.22 | 217.47 | 21.42 | 18.56 | ||
| Maximum of Months | 0.260152E+10 | 5990.77 | 30.83 | 27.85 | 81338261.00 | 217.49 | 30.33 | 27.56 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.309418E+10 | 1721.27 | 04-JAN-13:00 | 34.10 | 23.67 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.303448E+10 | 1843.57 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.356423E+10 | 2068.08 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.366295E+10 | 1997.11 | 30-APR-16:05 | 32.17 | 27.26 | 0.124621E+09 | 70.27 | 01-APR-02:49 | 32.17 | 27.26 |
| May | 0.396099E+10 | 2369.41 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.407990E+10 | 2382.70 | 16-JUN-16:03 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.372949E+10 | 2022.64 | 05-JUL-16:03 | 31.88 | 24.76 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.362250E+10 | 2038.45 | 09-AUG-16:08 | 32.50 | 27.45 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.340903E+10 | 1894.28 | 10-SEP-15:00 | 32.00 | 26.80 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.319680E+10 | 1758.46 | 29-OCT-13:00 | 31.90 | 26.18 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.304979E+10 | 1632.11 | 10-NOV-13:00 | 31.00 | 27.56 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.301643E+10 | 1621.74 | 09-DEC-14:00 | 31.00 | 25.03 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 31.00 | 25.03 |
| Annual Sum or Average | 0.414208E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.301643E+10 | 1621.74 | 31.00 | 23.67 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.407990E+10 | 2382.70 | 36.65 | 27.56 | 0.128775E+09 | 70.30 | 34.60 | 27.26 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.259558E+10 | 1311.53 | 05-JAN-17:03 | 30.73 | 23.57 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.248721E+10 | 1377.48 | 28-FEB-16:10 | 32.33 | 23.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 32.33 | 23.66 |
| March | 0.287427E+10 | 1577.89 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.294168E+10 | 1568.99 | 30-APR-16:05 | 32.17 | 27.26 | 0.124621E+09 | 70.27 | 01-APR-02:00 | 32.17 | 27.26 |
| May | 0.325535E+10 | 1800.48 | 06-MAY-16:04 | 34.58 | 27.24 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.335062E+10 | 1903.94 | 16-JUN-16:03 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.312224E+10 | 1668.62 | 14-JUL-17:17 | 32.57 | 25.09 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.298864E+10 | 1629.12 | 01-AUG-16:50 | 32.12 | 27.30 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.280181E+10 | 1471.29 | 02-SEP-17:10 | 32.08 | 26.93 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.269566E+10 | 1394.59 | 04-OCT-16:17 | 31.17 | 25.88 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.257402E+10 | 1321.44 | 04-NOV-16:10 | 29.60 | 24.92 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.255397E+10 | 1268.85 | 09-DEC-14:00 | 31.00 | 25.03 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 31.00 | 25.03 |
| Annual Sum or Average | 0.342411E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.248721E+10 | 1268.85 | 29.60 | 23.57 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.335062E+10 | 1903.94 | 34.58 | 27.30 | 0.128775E+09 | 70.30 | 34.25 | 27.26 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.259581E+10 | 1307.67 | 05-JAN-17:03 | 30.73 | 23.57 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.248764E+10 | 1376.25 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.287393E+10 | 1574.40 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.294200E+10 | 1566.32 | 30-APR-16:05 | 32.17 | 27.26 | 0.124621E+09 | 70.27 | 01-APR-03:09 | 32.17 | 27.26 |
| May | 0.325609E+10 | 1797.59 | 06-MAY-16:04 | 34.58 | 27.24 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.335142E+10 | 1900.74 | 16-JUN-16:03 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.312281E+10 | 1664.52 | 14-JUL-17:17 | 32.57 | 25.09 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.298957E+10 | 1626.69 | 01-AUG-16:50 | 32.12 | 27.30 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.280287E+10 | 1468.10 | 02-SEP-17:10 | 32.08 | 26.93 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.269587E+10 | 1390.58 | 04-OCT-16:17 | 31.17 | 25.88 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.257450E+10 | 1316.32 | 04-NOV-16:10 | 29.60 | 24.92 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.255419E+10 | 1268.94 | 09-DEC-14:00 | 31.00 | 25.03 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 31.00 | 25.03 |
| Annual Sum or Average | 0.342467E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.248764E+10 | 1268.94 | 29.60 | 23.57 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.335142E+10 | 1900.74 | 34.60 | 27.30 | 0.128775E+09 | 70.30 | 34.60 | 27.26 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.326683E+10 | 1861.13 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.298959E+10 | 1754.56 | 21-FEB-15:10 | 33.65 | 22.20 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 33.65 | 22.20 |
| March | 0.311719E+10 | 1810.89 | 19-MAR-16:10 | 34.25 | 25.05 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.291074E+10 | 1597.71 | 02-APR-16:02 | 33.25 | 27.16 | 0.123963E+09 | 70.27 | 01-APR-03:09 | 33.25 | 27.16 |
| May | 0.304857E+10 | 1655.57 | 06-MAY-16:04 | 34.58 | 27.24 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.297939E+10 | 1591.50 | 11-JUN-16:04 | 34.25 | 28.05 | 0.120421E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.290428E+10 | 1489.67 | 15-JUL-17:07 | 32.83 | 25.61 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 23.00 | 22.27 |
| August | 0.286897E+10 | 1514.41 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.286033E+10 | 1511.53 | 04-SEP-16:05 | 32.83 | 26.80 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.294287E+10 | 1679.36 | 29-OCT-13:00 | 31.90 | 26.18 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.304345E+10 | 1769.46 | 19-NOV-14:00 | 32.00 | 24.80 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.322715E+10 | 1826.80 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129276E+09 | 70.30 | 20-DEC-20:40 | 23.33 | 18.75 |
| Annual Sum or Average | 0.361594E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.286033E+10 | 1489.67 | 31.90 | 22.20 | 0.115109E+09 | 70.27 | 23.00 | 18.75 | ||
| Maximum of Months | 0.326683E+10 | 1861.13 | 34.58 | 28.05 | 0.129276E+09 | 70.30 | 34.25 | 27.16 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.358130E+10 | 1966.93 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 19-JAN-02:09 | 23.33 | 21.55 |
| February | 0.327082E+10 | 1896.08 | 20-FEB-16:10 | 32.58 | 24.26 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 32.58 | 24.26 |
| March | 0.341351E+10 | 1965.64 | 19-MAR-16:10 | 34.25 | 25.05 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.321384E+10 | 1750.81 | 02-APR-16:02 | 33.25 | 27.16 | 0.123963E+09 | 70.27 | 15-APR-05:19 | 25.50 | 24.34 |
| May | 0.336137E+10 | 1795.32 | 06-MAY-16:04 | 34.58 | 27.24 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.327912E+10 | 1748.46 | 11-JUN-16:04 | 34.25 | 28.05 | 0.120421E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.321329E+10 | 1630.12 | 30-JUL-16:07 | 30.95 | 24.98 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 30.95 | 24.98 |
| August | 0.315970E+10 | 1664.71 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.315620E+10 | 1676.27 | 04-SEP-16:05 | 32.83 | 26.80 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.324557E+10 | 1832.84 | 29-OCT-13:00 | 31.90 | 26.18 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.333916E+10 | 1924.37 | 19-NOV-14:00 | 32.00 | 24.80 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.352119E+10 | 1932.59 | 31-DEC-13:00 | 32.00 | 25.00 | 0.129276E+09 | 70.30 | 20-DEC-20:40 | 32.00 | 25.00 |
| Annual Sum or Average | 0.397551E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.315620E+10 | 1630.12 | 30.95 | 23.67 | 0.115109E+09 | 70.27 | 23.30 | 20.24 | ||
| Maximum of Months | 0.358130E+10 | 1966.93 | 34.58 | 28.05 | 0.129276E+09 | 70.30 | 34.25 | 26.18 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.372681E+10 | 2641.72 | 31-JAN-16:10 | 31.92 | 22.88 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 31.92 | 22.88 |
| February | 0.349609E+10 | 2612.14 | 28-FEB-15:20 | 34.20 | 24.48 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 34.20 | 24.48 |
| March | 0.383468E+10 | 2833.67 | 19-MAR-15:30 | 34.85 | 24.81 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.85 | 24.81 |
| April | 0.360745E+10 | 2510.82 | 02-APR-16:08 | 33.25 | 27.16 | 0.123963E+09 | 70.27 | 01-APR-02:49 | 33.25 | 27.16 |
| May | 0.365080E+10 | 2627.12 | 06-MAY-15:20 | 36.30 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.355789E+10 | 2441.42 | 16-JUN-16:10 | 33.17 | 26.74 | 0.120422E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.331216E+10 | 2239.85 | 04-JUL-16:07 | 31.17 | 25.29 | 0.129276E+09 | 70.29 | 19-JUL-18:00 | 23.00 | 22.27 |
| August | 0.330776E+10 | 2283.25 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.327188E+10 | 2282.81 | 10-SEP-15:00 | 32.00 | 26.80 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.335486E+10 | 2423.23 | 28-OCT-15:20 | 30.20 | 26.27 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 30.20 | 26.27 |
| November | 0.342207E+10 | 2425.30 | 19-NOV-14:30 | 31.75 | 24.87 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.360034E+10 | 2505.37 | 07-DEC-15:30 | 31.90 | 22.76 | 0.129276E+09 | 70.30 | 07-DEC-01:10 | 31.90 | 22.76 |
| Annual Sum or Average | 0.421428E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.327188E+10 | 2239.85 | 30.20 | 22.76 | 0.115109E+09 | 70.27 | 23.00 | 20.24 | ||
| Maximum of Months | 0.383468E+10 | 2833.67 | 36.30 | 27.35 | 0.129276E+09 | 70.30 | 34.85 | 27.16 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.303375E+10 | 2047.12 | 31-JAN-16:10 | 31.92 | 22.88 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 31.92 | 22.88 |
| February | 0.298511E+10 | 2203.24 | 28-FEB-16:10 | 32.33 | 23.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 32.33 | 23.66 |
| March | 0.359329E+10 | 2533.10 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.364128E+10 | 2448.58 | 11-APR-16:03 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-02:30 | 34.33 | 26.63 |
| May | 0.386498E+10 | 2779.97 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.393850E+10 | 2826.78 | 16-JUN-16:10 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.353380E+10 | 2453.75 | 04-JUL-16:20 | 30.83 | 25.29 | 0.128775E+09 | 70.29 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.343052E+10 | 2360.77 | 01-AUG-16:30 | 32.35 | 26.93 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.321167E+10 | 2218.39 | 02-SEP-16:30 | 32.25 | 26.67 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.310317E+10 | 2201.54 | 04-OCT-16:20 | 31.17 | 25.88 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.294099E+10 | 1980.50 | 04-NOV-16:10 | 29.60 | 24.92 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.290597E+10 | 1843.26 | 07-DEC-16:10 | 30.50 | 22.94 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 30.50 | 22.94 |
| Annual Sum or Average | 0.401830E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.290597E+10 | 1843.26 | 29.60 | 22.88 | 0.116313E+09 | 70.27 | 23.38 | 21.12 | ||
| Maximum of Months | 0.393850E+10 | 2826.78 | 36.65 | 27.35 | 0.128775E+09 | 70.30 | 34.33 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.372262E+10 | 2533.89 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.350421E+10 | 2383.42 | 28-FEB-15:00 | 35.00 | 24.83 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 35.00 | 24.83 |
| March | 0.381735E+10 | 2498.45 | 19-MAR-16:10 | 34.25 | 25.05 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.361340E+10 | 2156.97 | 01-APR-16:10 | 33.92 | 26.95 | 0.123963E+09 | 70.27 | 01-APR-02:00 | 33.92 | 26.95 |
| May | 0.367127E+10 | 2352.49 | 06-MAY-15:10 | 36.65 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.358112E+10 | 2133.73 | 16-JUN-15:10 | 32.23 | 26.77 | 0.120421E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.332464E+10 | 1914.22 | 29-JUL-16:05 | 31.58 | 23.90 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 31.58 | 23.90 |
| August | 0.333233E+10 | 1969.26 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.329732E+10 | 2031.25 | 10-SEP-15:00 | 32.00 | 26.80 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.336168E+10 | 2288.05 | 29-OCT-13:00 | 31.90 | 26.18 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.343039E+10 | 2307.11 | 18-NOV-13:00 | 34.30 | 25.34 | 0.123963E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.360119E+10 | 2361.87 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129276E+09 | 70.30 | 07-DEC-01:10 | 33.00 | 23.23 |
| Annual Sum or Average | 0.422575E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.329732E+10 | 1914.22 | 31.58 | 23.23 | 0.115109E+09 | 70.27 | 23.30 | 20.87 | ||
| Maximum of Months | 0.381735E+10 | 2533.89 | 36.65 | 27.35 | 0.129276E+09 | 70.30 | 35.00 | 26.95 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.302948E+10 | 1822.89 | 04-JAN-13:00 | 34.10 | 23.67 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.299292E+10 | 1964.05 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.357592E+10 | 2237.80 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.364719E+10 | 2086.30 | 11-APR-16:03 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-03:09 | 34.33 | 26.63 |
| May | 0.388553E+10 | 2508.23 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.396196E+10 | 2498.37 | 16-JUN-16:10 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.354632E+10 | 2121.27 | 13-JUL-16:05 | 32.08 | 24.17 | 0.128775E+09 | 70.29 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.345521E+10 | 2111.09 | 01-AUG-15:10 | 32.95 | 27.47 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.323712E+10 | 1964.87 | 10-SEP-15:00 | 32.00 | 26.80 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.310988E+10 | 1876.67 | 29-OCT-13:00 | 31.90 | 26.18 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.294914E+10 | 1715.45 | 10-NOV-13:00 | 31.00 | 27.56 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.290658E+10 | 1683.89 | 09-DEC-14:00 | 31.00 | 25.03 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 31.00 | 25.03 |
| Annual Sum or Average | 0.402973E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.290658E+10 | 1683.89 | 31.00 | 23.67 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.396196E+10 | 2508.23 | 36.65 | 27.56 | 0.128775E+09 | 70.30 | 34.60 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.251447E+10 | 1319.45 | 05-JAN-17:03 | 30.73 | 23.57 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.241517E+10 | 1420.57 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.282389E+10 | 1656.40 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.286812E+10 | 1599.20 | 30-APR-16:05 | 32.17 | 27.26 | 0.124621E+09 | 70.27 | 01-APR-02:49 | 32.17 | 27.26 |
| May | 0.314283E+10 | 1850.66 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.321025E+10 | 1959.48 | 16-JUN-16:10 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.295693E+10 | 1692.49 | 04-JUL-16:07 | 31.17 | 25.29 | 0.128775E+09 | 70.29 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.282977E+10 | 1641.53 | 01-AUG-16:30 | 32.35 | 26.93 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.264349E+10 | 1457.95 | 02-SEP-16:15 | 32.17 | 26.59 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.259927E+10 | 1417.16 | 04-OCT-16:20 | 31.17 | 25.88 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.247243E+10 | 1328.14 | 04-NOV-16:10 | 29.60 | 24.92 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.244933E+10 | 1288.02 | 09-DEC-14:00 | 31.00 | 25.03 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 31.00 | 25.03 |
| Annual Sum or Average | 0.329259E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.241517E+10 | 1288.02 | 29.60 | 23.57 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.321025E+10 | 1959.48 | 36.65 | 27.35 | 0.128775E+09 | 70.30 | 34.60 | 27.26 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.251471E+10 | 1315.72 | 03-JAN-17:03 | 31.73 | 24.07 | 0.128775E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.241569E+10 | 1419.98 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.282358E+10 | 1652.33 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.286848E+10 | 1596.06 | 30-APR-16:05 | 32.17 | 27.26 | 0.124621E+09 | 70.27 | 01-APR-02:00 | 32.17 | 27.26 |
| May | 0.314359E+10 | 1849.35 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.321111E+10 | 1955.70 | 16-JUN-16:10 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.295750E+10 | 1687.47 | 04-JUL-16:07 | 31.17 | 25.29 | 0.128775E+09 | 70.29 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.283071E+10 | 1638.86 | 01-AUG-16:30 | 32.35 | 26.93 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.264451E+10 | 1455.17 | 02-SEP-16:15 | 32.17 | 26.59 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.259956E+10 | 1412.52 | 04-OCT-16:03 | 31.33 | 25.85 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.247289E+10 | 1322.56 | 04-NOV-16:10 | 29.60 | 24.92 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.244961E+10 | 1288.21 | 09-DEC-14:00 | 31.00 | 25.03 | 0.128775E+09 | 70.30 | 07-DEC-01:10 | 31.00 | 25.03 |
| Annual Sum or Average | 0.329319E+11 | 0.151622E+10 | ||||||||
| Minimum of Months | 0.241569E+10 | 1288.21 | 29.60 | 24.07 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.321111E+10 | 1955.70 | 36.65 | 27.35 | 0.128775E+09 | 70.30 | 34.60 | 27.26 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.321253E+10 | 2007.19 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.292992E+10 | 1859.36 | 04-FEB-14:00 | 32.00 | 24.81 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 23.42 | 20.40 |
| March | 0.306710E+10 | 1916.73 | 19-MAR-16:10 | 34.25 | 25.05 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.283450E+10 | 1647.20 | 01-APR-16:10 | 33.92 | 26.95 | 0.123963E+09 | 70.27 | 01-APR-02:00 | 33.92 | 26.95 |
| May | 0.292775E+10 | 1695.27 | 06-MAY-15:10 | 36.65 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.282757E+10 | 1601.69 | 17-JUN-16:10 | 32.67 | 26.40 | 0.120421E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.273375E+10 | 1494.46 | 29-JUL-16:05 | 31.58 | 23.90 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 31.58 | 23.90 |
| August | 0.270630E+10 | 1516.72 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.270397E+10 | 1521.61 | 24-SEP-16:07 | 31.08 | 27.28 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 31.08 | 27.28 |
| October | 0.285300E+10 | 1779.09 | 29-OCT-13:00 | 31.90 | 26.18 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.295740E+10 | 1876.82 | 18-NOV-13:00 | 34.30 | 25.34 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.314915E+10 | 1946.43 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129276E+09 | 70.30 | 07-DEC-01:10 | 33.00 | 23.23 |
| Annual Sum or Average | 0.349030E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.270397E+10 | 1494.46 | 31.08 | 23.23 | 0.115109E+09 | 70.27 | 23.40 | 20.24 | ||
| Maximum of Months | 0.321253E+10 | 2007.19 | 36.65 | 27.35 | 0.129276E+09 | 70.30 | 34.25 | 27.28 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.321274E+10 | 2011.31 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.293041E+10 | 1861.96 | 04-FEB-14:00 | 32.00 | 24.81 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 23.42 | 20.40 |
| March | 0.306679E+10 | 1912.48 | 19-MAR-16:10 | 34.25 | 25.05 | 0.123963E+09 | 70.30 | 04-MAR-03:39 | 34.25 | 25.05 |
| April | 0.283487E+10 | 1643.68 | 01-APR-16:10 | 33.92 | 26.95 | 0.123963E+09 | 70.27 | 01-APR-02:00 | 33.92 | 26.95 |
| May | 0.292852E+10 | 1694.02 | 06-MAY-15:10 | 36.65 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.282844E+10 | 1599.20 | 17-JUN-16:10 | 32.67 | 26.40 | 0.120421E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.273434E+10 | 1493.37 | 29-JUL-16:05 | 31.58 | 23.90 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 31.58 | 23.90 |
| August | 0.270725E+10 | 1513.11 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.270499E+10 | 1519.55 | 24-SEP-16:07 | 31.08 | 27.28 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 31.08 | 27.28 |
| October | 0.285328E+10 | 1780.51 | 29-OCT-13:00 | 31.90 | 26.18 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.295783E+10 | 1878.78 | 18-NOV-13:00 | 34.30 | 25.34 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.314940E+10 | 1947.18 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129276E+09 | 70.30 | 07-DEC-01:10 | 33.00 | 23.23 |
| Annual Sum or Average | 0.349089E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.270499E+10 | 1493.37 | 31.08 | 23.23 | 0.115109E+09 | 70.27 | 23.40 | 20.24 | ||
| Maximum of Months | 0.321274E+10 | 2011.31 | 36.65 | 27.35 | 0.129276E+09 | 70.30 | 34.25 | 27.28 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.411714E+10 | 3612.93 | 05-JAN-15:00 | 34.00 | 23.37 | 0.129271E+09 | 70.30 | 24-JAN-06:30 | 19.50 | 17.57 |
| February | 0.392473E+10 | 3657.43 | 21-FEB-15:10 | 33.65 | 22.20 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 33.65 | 22.20 |
| March | 0.443931E+10 | 3974.30 | 19-MAR-15:30 | 34.85 | 24.81 | 0.123963E+09 | 70.30 | 04-MAR-05:40 | 34.85 | 24.81 |
| April | 0.425521E+10 | 3473.68 | 02-APR-16:02 | 33.25 | 27.16 | 0.123963E+09 | 70.27 | 01-APR-02:49 | 33.25 | 27.16 |
| May | 0.426996E+10 | 3711.95 | 06-MAY-15:20 | 36.30 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.418363E+10 | 3330.13 | 16-JUN-15:30 | 32.70 | 26.70 | 0.120422E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.377569E+10 | 3051.45 | 04-JUL-16:07 | 31.17 | 25.29 | 0.129276E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.375158E+10 | 3133.93 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.374697E+10 | 3232.06 | 10-SEP-15:00 | 32.00 | 26.80 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.372830E+10 | 3344.88 | 28-OCT-15:10 | 30.35 | 26.36 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 30.35 | 26.36 |
| November | 0.378165E+10 | 3368.09 | 19-NOV-14:10 | 31.92 | 24.82 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.392834E+10 | 3456.77 | 07-DEC-14:20 | 33.00 | 23.02 | 0.129256E+09 | 70.30 | 07-DEC-01:10 | 33.00 | 23.02 |
| Annual Sum or Average | 0.479025E+11 | 0.149639E+10 | ||||||||
| Minimum of Months | 0.372830E+10 | 3051.45 | 30.35 | 22.20 | 0.115109E+09 | 70.27 | 19.50 | 17.57 | ||
| Maximum of Months | 0.443931E+10 | 3974.30 | 36.30 | 27.35 | 0.129276E+09 | 70.30 | 34.85 | 27.16 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.336175E+10 | 2839.37 | 31-JAN-16:10 | 31.92 | 22.88 | 0.128764E+09 | 70.34 | 23-JAN-05:49 | 31.92 | 22.88 |
| February | 0.336974E+10 | 3112.21 | 28-FEB-15:20 | 34.20 | 24.48 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.20 | 24.48 |
| March | 0.417842E+10 | 3587.01 | 19-MAR-15:40 | 34.80 | 24.95 | 0.128775E+09 | 70.30 | 04-MAR-05:40 | 34.80 | 24.95 |
| April | 0.429631E+10 | 3443.50 | 11-APR-16:10 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-02:49 | 34.33 | 26.63 |
| May | 0.450900E+10 | 3911.46 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.460376E+10 | 3805.21 | 16-JUN-16:05 | 33.17 | 26.74 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.401901E+10 | 3332.75 | 04-JUL-16:07 | 31.17 | 25.29 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.388779E+10 | 3239.57 | 01-AUG-16:03 | 32.58 | 26.54 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.367984E+10 | 3147.35 | 10-SEP-15:00 | 32.00 | 26.80 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.345592E+10 | 3008.90 | 04-OCT-16:03 | 31.33 | 25.85 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.325872E+10 | 2647.98 | 04-NOV-15:20 | 30.33 | 25.36 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.317092E+10 | 2550.74 | 07-DEC-15:30 | 31.90 | 22.76 | 0.128737E+09 | 70.30 | 07-DEC-01:10 | 31.90 | 22.76 |
| Annual Sum or Average | 0.457912E+11 | 0.151617E+10 | ||||||||
| Minimum of Months | 0.317092E+10 | 2550.74 | 30.33 | 22.76 | 0.116313E+09 | 70.27 | 23.38 | 21.12 | ||
| Maximum of Months | 0.460376E+10 | 3911.46 | 36.65 | 27.35 | 0.128775E+09 | 70.34 | 34.80 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.410958E+10 | 3509.99 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129272E+09 | 70.31 | 24-JAN-06:30 | 19.50 | 17.57 |
| February | 0.393278E+10 | 3298.37 | 28-FEB-15:00 | 35.00 | 24.83 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 35.00 | 24.83 |
| March | 0.441482E+10 | 3437.50 | 19-MAR-15:30 | 34.85 | 24.81 | 0.123963E+09 | 70.30 | 04-MAR-05:40 | 34.85 | 24.81 |
| April | 0.426027E+10 | 2962.92 | 01-APR-15:30 | 34.60 | 26.82 | 0.123963E+09 | 70.27 | 01-APR-02:49 | 34.60 | 26.82 |
| May | 0.429465E+10 | 3292.71 | 06-MAY-15:10 | 36.65 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.421597E+10 | 2994.95 | 16-JUN-14:30 | 34.00 | 27.28 | 0.120422E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.379284E+10 | 2642.78 | 01-JUL-13:00 | 32.60 | 24.73 | 0.129276E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.378359E+10 | 2750.99 | 27-AUG-14:00 | 34.00 | 27.86 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 34.00 | 27.86 |
| September | 0.377797E+10 | 2849.76 | 10-SEP-15:00 | 32.00 | 26.80 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 23.30 | 23.30 |
| October | 0.373730E+10 | 3097.36 | 29-OCT-13:00 | 31.90 | 26.18 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.379059E+10 | 3225.02 | 18-NOV-13:00 | 34.30 | 25.34 | 0.123963E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.392844E+10 | 3268.74 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129261E+09 | 70.33 | 21-DEC-04:30 | 18.65 | 17.67 |
| Annual Sum or Average | 0.480388E+11 | 0.149640E+10 | ||||||||
| Minimum of Months | 0.373730E+10 | 2642.78 | 31.90 | 23.23 | 0.115109E+09 | 70.27 | 18.65 | 17.57 | ||
| Maximum of Months | 0.441482E+10 | 3509.99 | 36.65 | 27.86 | 0.129276E+09 | 70.33 | 35.00 | 27.86 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.335339E+10 | 2569.07 | 04-JAN-13:00 | 34.10 | 23.67 | 0.128767E+09 | 70.35 | 23-JAN-05:40 | 18.80 | 16.98 |
| February | 0.337700E+10 | 2763.80 | 28-FEB-15:00 | 35.00 | 24.83 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 35.00 | 24.83 |
| March | 0.415376E+10 | 3057.05 | 19-MAR-15:40 | 34.80 | 24.95 | 0.128775E+09 | 70.30 | 04-MAR-05:40 | 34.80 | 24.95 |
| April | 0.430128E+10 | 2872.29 | 11-APR-16:10 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-02:49 | 34.33 | 26.63 |
| May | 0.453380E+10 | 3494.47 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.463652E+10 | 3426.28 | 16-JUN-14:30 | 34.00 | 27.28 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.403633E+10 | 2831.40 | 04-JUL-15:10 | 31.92 | 24.89 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.392004E+10 | 2936.96 | 01-AUG-15:10 | 32.95 | 27.47 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.371081E+10 | 2767.11 | 10-SEP-15:00 | 32.00 | 26.80 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.346470E+10 | 2589.64 | 29-OCT-13:00 | 31.90 | 26.18 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 31.90 | 26.18 |
| November | 0.326714E+10 | 2356.45 | 18-NOV-13:00 | 34.30 | 25.34 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.316996E+10 | 2285.12 | 07-DEC-14:00 | 33.00 | 23.23 | 0.128747E+09 | 70.32 | 21-DEC-04:10 | 19.08 | 17.86 |
| Annual Sum or Average | 0.459247E+11 | 0.151619E+10 | ||||||||
| Minimum of Months | 0.316996E+10 | 2285.12 | 31.90 | 23.23 | 0.116313E+09 | 70.27 | 18.80 | 16.98 | ||
| Maximum of Months | 0.463652E+10 | 3494.47 | 36.65 | 27.47 | 0.128775E+09 | 70.35 | 35.00 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.280366E+10 | 1923.64 | 03-JAN-14:00 | 33.00 | 24.07 | 0.128774E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.275654E+10 | 2109.61 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.334324E+10 | 2372.33 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-05:40 | 34.25 | 25.05 |
| April | 0.346086E+10 | 2304.14 | 11-APR-16:10 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-02:49 | 34.33 | 26.63 |
| May | 0.373071E+10 | 2728.37 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.382411E+10 | 2724.16 | 16-JUN-15:10 | 32.23 | 26.77 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.340459E+10 | 2354.75 | 04-JUL-16:07 | 31.17 | 25.29 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.324883E+10 | 2331.34 | 01-AUG-15:10 | 32.95 | 27.47 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.307585E+10 | 2130.30 | 10-SEP-15:00 | 32.00 | 26.80 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.292564E+10 | 2021.60 | 04-OCT-15:10 | 32.33 | 26.11 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.276270E+10 | 1823.55 | 18-NOV-13:00 | 34.30 | 25.34 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.268378E+10 | 1793.81 | 30-DEC-14:00 | 32.00 | 25.37 | 0.128765E+09 | 70.30 | 07-DEC-01:10 | 32.00 | 25.37 |
| Annual Sum or Average | 0.380205E+11 | 0.151621E+10 | ||||||||
| Minimum of Months | 0.268378E+10 | 1793.81 | 31.17 | 24.07 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.382411E+10 | 2728.37 | 36.65 | 27.47 | 0.128775E+09 | 70.30 | 34.60 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.280410E+10 | 1926.09 | 03-JAN-14:00 | 33.00 | 24.07 | 0.128774E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.275742E+10 | 2106.07 | 28-FEB-15:10 | 34.60 | 24.66 | 0.116313E+09 | 70.30 | 09-FEB-05:10 | 34.60 | 24.66 |
| March | 0.334290E+10 | 2361.11 | 19-MAR-16:10 | 34.25 | 25.05 | 0.128775E+09 | 70.30 | 04-MAR-05:40 | 34.25 | 25.05 |
| April | 0.346143E+10 | 2292.66 | 11-APR-16:10 | 34.33 | 26.63 | 0.124621E+09 | 70.27 | 01-APR-02:49 | 34.33 | 26.63 |
| May | 0.373181E+10 | 2722.75 | 06-MAY-15:10 | 36.65 | 27.35 | 0.128775E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.382550E+10 | 2719.50 | 16-JUN-15:10 | 32.23 | 26.77 | 0.124621E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.340550E+10 | 2343.92 | 04-JUL-16:07 | 31.17 | 25.29 | 0.128775E+09 | 70.30 | 19-JUL-22:00 | 23.50 | 22.52 |
| August | 0.325023E+10 | 2328.76 | 01-AUG-15:10 | 32.95 | 27.47 | 0.128775E+09 | 70.28 | 24-AUG-02:30 | 23.50 | 23.50 |
| September | 0.307724E+10 | 2125.19 | 10-SEP-15:00 | 32.00 | 26.80 | 0.124621E+09 | 70.29 | 19-SEP-04:40 | 23.63 | 23.59 |
| October | 0.292622E+10 | 2015.47 | 04-OCT-15:10 | 32.33 | 26.11 | 0.128775E+09 | 70.29 | 24-OCT-01:19 | 23.53 | 23.41 |
| November | 0.276334E+10 | 1827.52 | 18-NOV-13:00 | 34.30 | 25.34 | 0.124621E+09 | 70.30 | 24-NOV-21:10 | 23.38 | 21.12 |
| December | 0.268439E+10 | 1794.90 | 30-DEC-14:00 | 32.00 | 25.37 | 0.128765E+09 | 70.30 | 07-DEC-01:10 | 32.00 | 25.37 |
| Annual Sum or Average | 0.380301E+11 | 0.151621E+10 | ||||||||
| Minimum of Months | 0.268439E+10 | 1794.90 | 31.17 | 24.07 | 0.116313E+09 | 70.27 | 23.38 | 20.87 | ||
| Maximum of Months | 0.382550E+10 | 2722.75 | 36.65 | 27.47 | 0.128775E+09 | 70.30 | 34.60 | 26.63 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.356764E+10 | 2859.06 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.331753E+10 | 2682.49 | 21-FEB-14:50 | 34.17 | 21.81 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 34.17 | 21.81 |
| March | 0.360692E+10 | 2735.63 | 19-MAR-15:30 | 34.85 | 24.81 | 0.123963E+09 | 70.30 | 04-MAR-05:40 | 34.85 | 24.81 |
| April | 0.341991E+10 | 2381.15 | 01-APR-16:04 | 33.92 | 26.95 | 0.123963E+09 | 70.27 | 01-APR-02:00 | 33.92 | 26.95 |
| May | 0.348969E+10 | 2524.46 | 06-MAY-15:10 | 36.65 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.340023E+10 | 2270.89 | 16-JUN-14:30 | 34.00 | 27.28 | 0.120422E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.315876E+10 | 2079.56 | 04-JUL-16:07 | 31.17 | 25.29 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 23.00 | 22.27 |
| August | 0.311143E+10 | 2151.85 | 27-AUG-16:05 | 32.83 | 25.70 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 32.83 | 25.70 |
| September | 0.314373E+10 | 2267.39 | 30-SEP-14:00 | 33.00 | 27.70 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 33.00 | 27.70 |
| October | 0.320117E+10 | 2547.69 | 28-OCT-13:30 | 31.95 | 26.58 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.95 | 26.58 |
| November | 0.329171E+10 | 2693.89 | 18-NOV-13:00 | 34.30 | 25.34 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.345045E+10 | 2773.51 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129273E+09 | 70.30 | 07-DEC-01:10 | 33.00 | 23.23 |
| Annual Sum or Average | 0.401592E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.311143E+10 | 2079.56 | 31.17 | 21.81 | 0.115109E+09 | 70.27 | 23.00 | 20.24 | ||
| Maximum of Months | 0.360692E+10 | 2859.06 | 36.65 | 27.70 | 0.129276E+09 | 70.30 | 34.85 | 27.70 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.356802E+10 | 2866.70 | 04-JAN-13:00 | 34.10 | 23.67 | 0.129276E+09 | 70.30 | 17-JAN-02:00 | 23.40 | 20.87 |
| February | 0.331837E+10 | 2679.93 | 21-FEB-14:50 | 34.17 | 21.81 | 0.115109E+09 | 70.30 | 09-FEB-05:10 | 34.17 | 21.81 |
| March | 0.360658E+10 | 2726.87 | 19-MAR-15:20 | 34.90 | 24.67 | 0.123963E+09 | 70.30 | 04-MAR-05:40 | 34.90 | 24.67 |
| April | 0.342049E+10 | 2371.10 | 01-APR-16:04 | 33.92 | 26.95 | 0.123963E+09 | 70.27 | 01-APR-02:00 | 33.92 | 26.95 |
| May | 0.349081E+10 | 2518.96 | 06-MAY-15:10 | 36.65 | 27.35 | 0.125734E+09 | 70.29 | 10-MAY-21:30 | 23.60 | 23.60 |
| June | 0.340164E+10 | 2270.28 | 16-JUN-14:30 | 34.00 | 27.28 | 0.120422E+09 | 70.28 | 21-JUN-02:30 | 23.50 | 23.50 |
| July | 0.315968E+10 | 2068.85 | 04-JUL-16:07 | 31.17 | 25.29 | 0.129276E+09 | 70.30 | 19-JUL-18:00 | 23.00 | 22.27 |
| August | 0.311284E+10 | 2143.69 | 13-AUG-15:20 | 32.77 | 28.01 | 0.123963E+09 | 70.29 | 19-AUG-18:40 | 23.60 | 23.11 |
| September | 0.314512E+10 | 2265.36 | 30-SEP-13:50 | 32.97 | 27.61 | 0.123963E+09 | 70.29 | 15-SEP-19:00 | 32.97 | 27.61 |
| October | 0.320174E+10 | 2549.52 | 28-OCT-13:30 | 31.95 | 26.58 | 0.127505E+09 | 70.29 | 24-OCT-01:19 | 31.95 | 26.58 |
| November | 0.329232E+10 | 2697.61 | 18-NOV-13:00 | 34.30 | 25.34 | 0.123963E+09 | 70.30 | 25-NOV-09:09 | 23.67 | 20.24 |
| December | 0.345097E+10 | 2774.24 | 07-DEC-14:00 | 33.00 | 23.23 | 0.129273E+09 | 70.30 | 07-DEC-01:10 | 33.00 | 23.23 |
| Annual Sum or Average | 0.401686E+11 | 0.149641E+10 | ||||||||
| Minimum of Months | 0.311284E+10 | 2068.85 | 31.17 | 21.81 | 0.115109E+09 | 70.27 | 23.00 | 20.24 | ||
| Maximum of Months | 0.360658E+10 | 2866.70 | 36.65 | 28.01 | 0.129276E+09 | 70.30 | 34.90 | 27.61 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.289340E+09 | 167.77 | 03-JAN-21:10 | 27.58 | 23.54 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.264445E+09 | 169.45 | 26-FEB-21:10 | 28.33 | 21.91 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.297369E+09 | 174.47 | 20-MAR-20:10 | 28.00 | 23.05 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.292113E+09 | 176.75 | 30-APR-20:10 | 29.53 | 26.24 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 | 0.301995E+09 | 181.68 | 06-MAY-20:10 | 30.83 | 25.83 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.294064E+09 | 180.38 | 12-JUN-20:10 | 29.97 | 26.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.296200E+09 | 177.65 | 15-JUL-20:10 | 28.92 | 25.01 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.294239E+09 | 175.01 | 01-AUG-20:10 | 29.00 | 27.47 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 | 0.286111E+09 | 174.02 | 13-SEP-20:10 | 29.92 | 26.86 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.291675E+09 | 171.09 | 04-OCT-20:10 | 27.92 | 25.10 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.280433E+09 | 169.23 | 03-NOV-20:10 | 25.50 | 24.73 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.286185E+09 | 168.27 | 08-DEC-21:10 | 28.02 | 24.22 |
| Annual Sum or Average | 0.00 | 0.347417E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.264445E+09 | 167.77 | 25.50 | 21.91 | ||
| Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.301995E+09 | 181.68 | 30.83 | 27.47 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.317064E+09 | 188.24 | 03-JAN-18:10 | 30.17 | 24.16 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.293626E+09 | 201.44 | 06-FEB-18:10 | 31.22 | 24.53 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.330143E+09 | 207.54 | 19-MAR-17:10 | 31.67 | 23.98 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.325834E+09 | 213.23 | 11-APR-17:10 | 32.67 | 26.58 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 | 0.337207E+09 | 224.49 | 29-MAY-17:10 | 33.83 | 26.60 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.327545E+09 | 225.34 | 12-JUN-17:10 | 33.67 | 27.22 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.324659E+09 | 212.90 | 15-JUL-17:10 | 32.83 | 25.61 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.323820E+09 | 205.09 | 27-AUG-17:10 | 31.67 | 26.84 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 | 0.314071E+09 | 207.65 | 02-SEP-17:10 | 32.08 | 26.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.317787E+09 | 188.92 | 04-OCT-17:10 | 30.33 | 25.99 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.307043E+09 | 185.60 | 19-NOV-21:10 | 27.93 | 25.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.313013E+09 | 183.61 | 08-DEC-21:10 | 28.02 | 24.22 |
| Annual Sum or Average | 0.00 | 0.383181E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.293626E+09 | 183.61 | 27.93 | 23.98 | ||
| Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.337207E+09 | 225.34 | 33.83 | 27.22 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.286956E+09 | 160.77 | 05-JAN-21:10 | 26.92 | 23.35 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.261265E+09 | 161.25 | 22-FEB-21:10 | 27.43 | 22.28 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.290292E+09 | 163.42 | 20-MAR-20:10 | 28.00 | 23.05 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.281969E+09 | 163.57 | 30-APR-20:10 | 29.53 | 26.24 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 | 0.291199E+09 | 166.64 | 06-MAY-20:10 | 30.83 | 25.83 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.283087E+09 | 165.89 | 12-JUN-20:10 | 29.97 | 26.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.288283E+09 | 163.10 | 15-JUL-20:10 | 28.92 | 25.01 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.287192E+09 | 162.30 | 01-AUG-20:10 | 29.00 | 27.47 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 | 0.278201E+09 | 161.85 | 13-SEP-20:10 | 29.92 | 26.86 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.285996E+09 | 160.92 | 04-OCT-20:10 | 27.92 | 25.10 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.276997E+09 | 160.37 | 04-NOV-20:10 | 26.95 | 25.04 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.285455E+09 | 159.97 | 08-DEC-21:10 | 28.02 | 24.22 |
| Annual Sum or Average | 0.00 | 0.339689E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.261265E+09 | 159.97 | 26.92 | 22.28 | ||
| Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.291199E+09 | 166.64 | 30.83 | 27.47 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.320838E+09 | 565.81 | 03-JAN-17:13 | 31.47 |
| February | 0.335532E+09 | 629.26 | 24-FEB-17:13 | 32.33 |
| March | 0.435269E+09 | 666.72 | 29-MAR-16:13 | 33.27 |
| April | 0.457865E+09 | 697.99 | 11-APR-16:13 | 34.07 |
| May | 0.403780E+09 | 722.08 | 05-MAY-16:01 | 35.17 |
| June | 0.415275E+09 | 716.47 | 13-JUN-16:01 | 35.08 |
| July | 0.409830E+09 | 674.18 | 20-JUL-16:13 | 32.63 |
| August | 0.457385E+09 | 637.70 | 01-AUG-16:13 | 32.47 |
| September | 0.416179E+09 | 642.83 | 13-SEP-16:13 | 32.33 |
| October | 0.412804E+09 | 590.11 | 04-OCT-16:13 | 31.17 |
| November | 0.357022E+09 | 563.49 | 03-NOV-16:13 | 30.47 |
| December | 0.323432E+09 | 553.54 | 13-DEC-17:13 | 30.33 |
| Annual Sum or Average | 0.474521E+10 | |||
| Minimum of Months | 0.320838E+09 | 553.54 | 30.33 | |
| Maximum of Months | 0.457865E+09 | 722.08 | 35.17 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76139806.18 | 7339945.98 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101114E+09 | 669775.22 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.174507E+09 | 543020.19 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161974E+09 | 11041.98 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181745E+09 | 97955.84 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169454E+09 | 409192.47 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106201E+09 | 230406.57 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134838E+09 | 599699.77 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95794409.82 | 307802.97 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79238598.74 | 443121.53 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63039324.26 | 1969404.83 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58216232.49 | 9592318.71 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140226E+10 | 22213686.06 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58216232.49 | 11041.98 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181745E+09 | 9592318.71 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76139790.35 | 7339946.33 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101114E+09 | 669775.00 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.174507E+09 | 543020.33 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161974E+09 | 11041.99 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181745E+09 | 97955.87 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169454E+09 | 409192.70 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106201E+09 | 230406.31 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134838E+09 | 599699.95 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95794403.23 | 307802.73 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79238587.05 | 443121.79 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63039311.72 | 1969404.76 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58216219.06 | 9592317.61 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140226E+10 | 22213685.36 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58216219.06 | 11041.99 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181745E+09 | 9592317.61 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 39845813.29 | 53473662.09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 54887785.30 | 29706775.98 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 90880923.67 | 51290655.85 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 74590888.94 | 23024046.51 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 97701247.85 | 26727865.77 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 89604005.81 | 28796838.24 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 51292056.87 | 26119150.21 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 73507831.43 | 44708243.54 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 50482745.96 | 27023162.90 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 40331356.38 | 34856995.78 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 33856859.39 | 36883652.75 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30669009.49 | 51937387.12 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.727651E+09 | 0.434548E+09 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30669009.49 | 23024046.51 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 97701247.85 | 53473662.09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76139799.24 | 7339945.49 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101114E+09 | 669774.66 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.174507E+09 | 543019.73 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161974E+09 | 11041.96 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181745E+09 | 97955.47 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169454E+09 | 409192.10 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106201E+09 | 230406.15 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134838E+09 | 599699.15 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95794417.15 | 307802.40 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79238599.19 | 443120.97 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63039321.01 | 1969403.72 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58216225.43 | 9592315.78 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140226E+10 | 22213677.57 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58216225.43 | 11041.96 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181745E+09 | 9592315.78 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45925600.28 | 4427267.43 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60989448.52 | 403990.57 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105258E+09 | 327534.86 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 97698907.67 | 6660.20 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 59084.02 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102211E+09 | 246813.58 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64057500.82 | 138975.13 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81331085.78 | 361722.10 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57780763.61 | 185658.18 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47794716.57 | 267278.43 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38023723.26 | 1187893.20 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35114554.84 | 5785838.86 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.845809E+09 | 13398716.55 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35114554.84 | 6660.20 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 5785838.86 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45925600.42 | 4427267.41 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60989448.69 | 403990.56 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105258E+09 | 327534.85 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 97698907.94 | 6660.20 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 59084.01 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102211E+09 | 246813.57 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64057501.05 | 138975.13 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81331086.14 | 361722.08 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57780763.85 | 185658.18 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47794716.77 | 267278.42 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38023723.41 | 1187893.18 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35114554.95 | 5785838.82 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.845809E+09 | 13398716.41 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35114554.95 | 6660.20 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 5785838.82 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45925608.81 | 4427267.12 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60989457.32 | 403990.77 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105258E+09 | 327534.84 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 97698908.85 | 6660.20 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 59084.05 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102211E+09 | 246813.51 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64057498.29 | 138975.39 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81331084.44 | 361722.10 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57780766.59 | 185658.34 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47794722.65 | 267278.35 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38023730.13 | 1187893.31 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35114562.21 | 5785839.64 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.845809E+09 | 13398717.62 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35114562.21 | 6660.20 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 5785839.64 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45925610.81 | 4427266.97 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60989459.65 | 403991.09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105258E+09 | 327535.08 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 97698913.06 | 6660.20 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 59083.92 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102211E+09 | 246813.62 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64057501.11 | 138975.18 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81331088.98 | 361722.42 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57780769.57 | 185658.40 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47794725.32 | 267278.44 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38023732.14 | 1187893.66 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35114563.83 | 5785840.22 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.845809E+09 | 13398719.20 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35114563.83 | 6660.20 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109624E+09 | 5785840.22 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108880E+09 | 10667822.23 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144713E+09 | 988711.64 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249757E+09 | 823894.39 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231936E+09 | 17759.40 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 162917.96 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242682E+09 | 619247.04 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151969E+09 | 354652.16 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192885E+09 | 909413.50 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137065E+09 | 469212.91 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113285E+09 | 686487.12 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90111475.76 | 2898398.02 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83241787.39 | 13951178.45 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200681E+10 | 32549694.83 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83241787.39 | 17759.40 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 13951178.45 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108880E+09 | 10667821.64 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144713E+09 | 988711.18 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249757E+09 | 823894.46 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231936E+09 | 17759.42 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 162918.04 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242682E+09 | 619247.43 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151969E+09 | 354651.76 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192885E+09 | 909413.64 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137065E+09 | 469212.44 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113285E+09 | 686487.38 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90111459.13 | 2898397.69 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83241770.33 | 13951175.38 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200681E+10 | 32549690.46 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83241770.33 | 17759.42 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 13951175.38 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108880E+09 | 10667821.66 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144713E+09 | 988711.28 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249757E+09 | 823893.69 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231936E+09 | 17759.36 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 162917.52 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242682E+09 | 619246.33 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151969E+09 | 354652.22 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192885E+09 | 909412.60 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137065E+09 | 469212.60 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113285E+09 | 686486.16 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90111488.68 | 2898396.79 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83241795.89 | 13951176.47 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200681E+10 | 32549686.70 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83241795.89 | 17759.36 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 13951176.47 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108880E+09 | 10667820.71 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144713E+09 | 988710.78 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249757E+09 | 823893.44 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231936E+09 | 17759.36 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 162917.39 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242682E+09 | 619246.43 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151969E+09 | 354651.55 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192885E+09 | 909412.31 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137065E+09 | 469211.96 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113285E+09 | 686486.03 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90111474.43 | 2898396.02 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83241780.70 | 13951172.82 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200681E+10 | 32549678.82 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83241780.70 | 17759.36 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260280E+09 | 13951172.82 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65673748.23 | 6434557.45 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 87287166.56 | 596364.64 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150647E+09 | 496950.62 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139898E+09 | 10711.96 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 98267.36 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146379E+09 | 373512.83 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91664011.22 | 213916.84 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116343E+09 | 548532.89 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82674328.53 | 283016.22 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68330493.03 | 414069.93 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54352960.43 | 1748237.79 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50209336.76 | 8414990.86 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121045E+10 | 19633129.37 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 50209336.76 | 10711.96 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 8414990.86 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65673748.46 | 6434557.42 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 87287166.83 | 596364.63 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150647E+09 | 496950.61 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139898E+09 | 10711.96 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 98267.35 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146379E+09 | 373512.81 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91664011.56 | 213916.84 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116343E+09 | 548532.87 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82674328.90 | 283016.21 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68330493.34 | 414069.91 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54352960.67 | 1748237.76 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50209336.94 | 8414990.80 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121045E+10 | 19633129.18 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 50209336.94 | 10711.96 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 8414990.80 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65673760.50 | 6434557.12 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 87287179.58 | 596364.88 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150647E+09 | 496950.52 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139898E+09 | 10711.95 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 98267.31 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146379E+09 | 373512.56 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91664010.16 | 213917.19 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116343E+09 | 548532.77 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82674334.51 | 283016.43 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68330503.13 | 414069.69 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54352970.73 | 1748237.79 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50209347.05 | 8414992.13 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121045E+10 | 19633130.33 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 50209347.05 | 10711.95 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 8414992.13 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65673760.75 | 6434557.10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 87287179.88 | 596364.86 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150647E+09 | 496950.50 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139898E+09 | 10711.95 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 98267.30 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146379E+09 | 373512.54 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91664010.57 | 213917.19 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116343E+09 | 548532.75 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82674334.90 | 283016.42 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68330503.46 | 414069.67 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54352971.00 | 1748237.76 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50209347.24 | 8414992.06 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121045E+10 | 19633130.11 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 50209347.24 | 10711.95 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156994E+09 | 8414992.06 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142603E+09 | 14423283.01 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189851E+09 | 1378942.95 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327675E+09 | 1207637.43 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304600E+09 | 29422.06 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 276898.58 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318805E+09 | 904217.18 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199309E+09 | 533740.66 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252798E+09 | 1330577.24 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179727E+09 | 692994.20 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148301E+09 | 1041770.97 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117929E+09 | 4016721.82 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 18856078.01 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263251E+10 | 44692284.10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 29422.06 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 18856078.01 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142603E+09 | 14413039.50 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189851E+09 | 1378942.36 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327675E+09 | 1207637.70 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304600E+09 | 29422.09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 276898.89 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318805E+09 | 904217.78 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199309E+09 | 533740.33 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252798E+09 | 1330577.56 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179727E+09 | 692993.37 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148301E+09 | 1041771.49 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117929E+09 | 4016721.71 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 18819484.18 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263251E+10 | 44645446.95 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 29422.09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 18819484.18 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142603E+09 | 14424508.60 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189851E+09 | 1378942.69 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327675E+09 | 1207636.10 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304600E+09 | 29421.96 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 276897.59 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318806E+09 | 904215.79 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199309E+09 | 533740.46 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252798E+09 | 1330575.36 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179727E+09 | 692993.65 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148301E+09 | 1041769.20 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117929E+09 | 4016719.89 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 18868031.56 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263252E+10 | 44705452.85 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 29421.96 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 18868031.56 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142603E+09 | 14417529.26 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189851E+09 | 1378942.22 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327675E+09 | 1207635.92 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304600E+09 | 29421.97 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 276897.57 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318806E+09 | 904215.96 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199309E+09 | 533739.72 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252798E+09 | 1330575.02 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179727E+09 | 692992.63 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148301E+09 | 1041769.14 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117929E+09 | 4016719.11 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 18840323.37 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263252E+10 | 44670761.88 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109003E+09 | 29421.97 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341914E+09 | 18840323.37 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 86014574.97 | 8702893.01 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114513E+09 | 831742.50 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197645E+09 | 728414.86 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183727E+09 | 17746.55 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 167017.25 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192295E+09 | 545399.24 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120218E+09 | 321938.28 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152481E+09 | 802567.53 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108407E+09 | 417995.08 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89451515.76 | 628367.86 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71131811.63 | 2422782.62 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65747812.85 | 11384600.10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158787E+10 | 26971464.88 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 65747812.85 | 17746.55 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 11384600.10 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 86014575.83 | 8702846.60 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114513E+09 | 831742.47 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197645E+09 | 728414.82 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183727E+09 | 17746.55 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 167017.22 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192295E+09 | 545399.19 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120218E+09 | 321938.27 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152481E+09 | 802567.46 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108407E+09 | 417995.06 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89451516.91 | 628367.79 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71131812.48 | 2422782.53 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65747813.48 | 11384729.26 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158787E+10 | 26971547.20 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 65747813.48 | 17746.55 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 11384729.26 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 86014596.96 | 8703810.70 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114513E+09 | 831742.85 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197645E+09 | 728414.85 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183727E+09 | 17746.54 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 167017.21 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192295E+09 | 545399.05 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120218E+09 | 321938.75 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152481E+09 | 802567.61 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108407E+09 | 417995.66 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89451531.41 | 628367.73 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71131828.92 | 2422782.80 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65747830.84 | 11393936.23 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158787E+10 | 26981719.98 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 65747830.84 | 17746.54 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 11393936.23 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 86014597.90 | 8703797.67 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114513E+09 | 831742.82 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197645E+09 | 728414.81 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183727E+09 | 17746.54 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 167017.17 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192295E+09 | 545399.00 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120218E+09 | 321938.74 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152481E+09 | 802567.54 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108407E+09 | 417995.62 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89451532.57 | 628367.66 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71131829.86 | 2422782.71 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65747831.56 | 11393960.51 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158787E+10 | 26981730.80 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 65747831.56 | 17746.54 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206234E+09 | 11393960.51 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10497634.87 | 6732325.54 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15736171.50 | 2057498.88 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27223316.70 | 2661929.69 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27031487.73 | 441751.67 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32007670.84 | 1878091.42 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28884768.25 | 1813851.62 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16108890.09 | 2333541.42 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20319986.15 | 3597576.39 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14625059.93 | 2343994.37 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10834697.57 | 3425814.83 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8392574.49 | 3860215.60 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7795310.49 | 7909382.59 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219458E+09 | 39055974.01 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7795310.49 | 441751.67 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32007670.84 | 7909382.59 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266280E+09 | 0.232564E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336769E+09 | 0.150760E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.444918E+09 | 81447766.17 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.491177E+09 | 36103808.28 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.530777E+09 | 57055266.38 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.494642E+09 | 63298009.58 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291769E+09 | 0.151037E+09 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.301559E+09 | 0.115153E+09 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.296539E+09 | 0.116860E+09 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215998E+09 | 0.148848E+09 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200657E+09 | 0.158121E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200024E+09 | 0.219498E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407111E+10 | 0.153074E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200024E+09 | 36103808.28 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.530777E+09 | 0.232564E+09 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9690254.02 | 5186112.21 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14193603.25 | 1575553.10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24232847.51 | 2039978.44 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23953114.72 | 327917.25 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28001325.31 | 1227611.59 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25514574.64 | 1177331.23 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14715142.45 | 1459214.10 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18065099.95 | 2400503.95 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13267431.41 | 1477632.58 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10014475.66 | 2377447.69 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7770522.33 | 2914521.88 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7229440.62 | 6108833.23 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196648E+09 | 28272657.24 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7229440.62 | 327917.25 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28001325.31 | 6108833.23 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.90 | 04-JAN-13:00 | 133.30 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.45 | 28-FEB-15:00 | 34.03 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 358.29 | 19-MAR-16:00 | 23.39 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.52 | 04-APR-14:00 | 12.80 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 336.27 | 06-MAY-15:00 | 18.62 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.65 | 16-JUN-15:00 | 19.42 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 225.97 | 01-JUL-13:00 | 21.74 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.10 | 06-AUG-13:00 | 38.93 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 271.02 | 10-SEP-15:00 | 34.85 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 237.82 | 29-OCT-13:10 | 16.31 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 10-NOV-13:00 | 31.36 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.12 | 09-DEC-14:00 | 71.31 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 12.80 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 358.29 | 133.30 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.90 | 04-JAN-13:00 | 133.30 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.45 | 28-FEB-15:00 | 34.03 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 358.29 | 19-MAR-16:00 | 23.39 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.52 | 04-APR-14:00 | 12.80 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 336.27 | 06-MAY-15:00 | 18.62 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.65 | 16-JUN-15:00 | 19.42 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 225.97 | 01-JUL-13:00 | 21.74 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.10 | 06-AUG-13:00 | 38.93 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 271.02 | 10-SEP-15:00 | 34.85 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 237.82 | 29-OCT-13:10 | 16.31 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 10-NOV-13:00 | 31.36 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.12 | 09-DEC-14:00 | 71.31 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 12.80 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 358.29 | 133.30 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 188.89 | 04-JAN-13:00 | 381.78 | 07-JAN-05:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 254.43 | 28-FEB-15:00 | 86.75 | 01-FEB-07:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 260.76 | 17-MAR-15:00 | 93.83 | 14-MAR-22:00 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.49 | 04-APR-14:00 | 77.52 | 09-APR-16:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 275.60 | 04-MAY-13:00 | 169.82 | 08-MAY-22:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.59 | 16-JUN-15:00 | 182.62 | 20-JUN-23:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 201.38 | 05-JUL-14:00 | 101.40 | 19-JUL-19:00 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 211.90 | 24-AUG-13:00 | 146.19 | 23-AUG-20:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 189.36 | 14-SEP-13:00 | 128.93 | 15-SEP-17:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.60 | 04-OCT-15:00 | 80.26 | 29-OCT-17:30 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 10-NOV-13:00 | 80.40 | 26-NOV-10:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 132.24 | 19-DEC-14:00 | 106.11 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 132.24 | 77.52 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 299.59 | 381.78 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.90 | 04-JAN-13:00 | 133.30 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.45 | 28-FEB-15:00 | 34.03 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 358.29 | 19-MAR-16:00 | 23.39 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.52 | 04-APR-14:00 | 12.80 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 336.27 | 06-MAY-15:00 | 18.62 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.65 | 16-JUN-15:00 | 19.42 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 225.97 | 01-JUL-13:00 | 21.74 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.10 | 06-AUG-13:00 | 38.93 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 271.02 | 10-SEP-15:00 | 34.85 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 237.82 | 29-OCT-13:10 | 16.31 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 10-NOV-13:00 | 31.36 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.12 | 09-DEC-14:00 | 71.31 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 12.80 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 358.29 | 133.30 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.94 | 04-JAN-13:00 | 80.41 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.48 | 28-FEB-15:00 | 20.53 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 19-MAR-16:00 | 14.11 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.97 | 04-APR-14:00 | 7.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.83 | 06-MAY-15:00 | 11.23 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.74 | 16-JUN-15:00 | 11.72 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 136.30 | 01-JUL-13:00 | 13.11 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.04 | 06-AUG-13:00 | 23.48 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.47 | 10-SEP-15:00 | 21.02 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.44 | 29-OCT-13:10 | 9.84 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 10-NOV-13:00 | 18.91 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.66 | 09-DEC-14:00 | 43.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 7.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 80.41 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.94 | 04-JAN-13:00 | 80.41 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.48 | 28-FEB-15:00 | 20.53 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 19-MAR-16:00 | 14.11 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.97 | 04-APR-14:00 | 7.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.83 | 06-MAY-15:00 | 11.23 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.74 | 16-JUN-15:00 | 11.72 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 136.30 | 01-JUL-13:00 | 13.11 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.04 | 06-AUG-13:00 | 23.48 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.47 | 10-SEP-15:00 | 21.02 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.44 | 29-OCT-13:10 | 9.84 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 10-NOV-13:00 | 18.91 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.66 | 09-DEC-14:00 | 43.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 7.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 80.41 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.94 | 04-JAN-13:00 | 80.41 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.48 | 28-FEB-15:00 | 20.53 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 19-MAR-16:00 | 14.11 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.97 | 04-APR-14:00 | 7.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.83 | 06-MAY-15:00 | 11.23 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.74 | 16-JUN-15:00 | 11.72 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 136.30 | 01-JUL-13:00 | 13.11 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.04 | 06-AUG-13:00 | 23.48 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.47 | 10-SEP-15:00 | 21.02 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.44 | 29-OCT-13:10 | 9.84 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 10-NOV-13:00 | 18.91 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.66 | 09-DEC-14:00 | 43.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 7.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 80.41 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.94 | 04-JAN-13:00 | 80.41 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.48 | 28-FEB-15:00 | 20.53 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 19-MAR-16:00 | 14.11 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.97 | 04-APR-14:00 | 7.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.83 | 06-MAY-15:00 | 11.23 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.74 | 16-JUN-15:00 | 11.72 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 136.30 | 01-JUL-13:00 | 13.11 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.04 | 06-AUG-13:00 | 23.48 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.47 | 10-SEP-15:00 | 21.02 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.44 | 29-OCT-13:10 | 9.84 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 10-NOV-13:00 | 18.91 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.66 | 09-DEC-14:00 | 43.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.81 | 7.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 216.11 | 80.41 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.93 | 04-JAN-13:00 | 193.57 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 365.01 | 28-FEB-15:00 | 49.24 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 19-MAR-16:00 | 33.94 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.77 | 04-APR-14:00 | 18.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 482.51 | 06-MAY-15:00 | 27.63 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 429.55 | 16-JUN-15:00 | 28.47 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.98 | 01-JUL-13:00 | 32.01 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 354.13 | 06-AUG-13:00 | 56.50 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 10-SEP-15:00 | 51.08 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 340.88 | 29-OCT-13:10 | 23.75 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 10-NOV-13:00 | 45.29 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 265.28 | 09-DEC-14:00 | 102.81 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 193.57 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.93 | 04-JAN-13:00 | 193.56 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 365.01 | 28-FEB-15:00 | 49.24 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 19-MAR-16:00 | 33.94 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.77 | 04-APR-14:00 | 18.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 482.51 | 06-MAY-15:00 | 27.63 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 429.55 | 16-JUN-15:00 | 28.47 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.98 | 01-JUL-13:00 | 32.01 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 354.13 | 06-AUG-13:00 | 56.50 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 10-SEP-15:00 | 51.08 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 340.88 | 29-OCT-13:10 | 23.75 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 10-NOV-13:00 | 45.29 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 265.28 | 09-DEC-14:00 | 102.81 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 193.56 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.93 | 04-JAN-13:00 | 193.57 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 365.01 | 28-FEB-15:00 | 49.24 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 19-MAR-16:00 | 33.94 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.77 | 04-APR-14:00 | 18.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 482.51 | 06-MAY-15:00 | 27.63 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 429.55 | 16-JUN-15:00 | 28.47 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.98 | 01-JUL-13:00 | 32.01 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 354.13 | 06-AUG-13:00 | 56.50 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 10-SEP-15:00 | 51.08 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 340.88 | 29-OCT-13:10 | 23.75 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 10-NOV-13:00 | 45.29 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 265.28 | 09-DEC-14:00 | 102.81 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 193.57 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.93 | 04-JAN-13:00 | 193.56 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 365.01 | 28-FEB-15:00 | 49.24 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 19-MAR-16:00 | 33.94 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.77 | 04-APR-14:00 | 18.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 482.51 | 06-MAY-15:00 | 27.63 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 429.55 | 16-JUN-15:00 | 28.47 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.98 | 01-JUL-13:00 | 32.01 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 354.13 | 06-AUG-13:00 | 56.50 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 10-SEP-15:00 | 51.08 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 340.88 | 29-OCT-13:10 | 23.75 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 10-NOV-13:00 | 45.29 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 265.28 | 09-DEC-14:00 | 102.81 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 513.94 | 193.56 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.42 | 04-JAN-13:00 | 116.75 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.16 | 28-FEB-15:00 | 29.70 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 19-MAR-16:00 | 20.47 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.80 | 04-APR-14:00 | 11.29 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.04 | 06-MAY-15:00 | 16.67 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 259.10 | 16-JUN-15:00 | 17.17 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 195.42 | 01-JUL-13:00 | 19.31 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 213.60 | 06-AUG-13:00 | 34.08 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.34 | 10-SEP-15:00 | 30.81 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.61 | 29-OCT-13:10 | 14.32 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 10-NOV-13:00 | 27.32 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 160.01 | 09-DEC-14:00 | 62.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 11.29 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 116.75 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.42 | 04-JAN-13:00 | 116.75 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.16 | 28-FEB-15:00 | 29.70 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 19-MAR-16:00 | 20.47 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.80 | 04-APR-14:00 | 11.29 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.04 | 06-MAY-15:00 | 16.67 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 259.10 | 16-JUN-15:00 | 17.17 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 195.42 | 01-JUL-13:00 | 19.31 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 213.60 | 06-AUG-13:00 | 34.08 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.34 | 10-SEP-15:00 | 30.81 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.61 | 29-OCT-13:10 | 14.32 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 10-NOV-13:00 | 27.32 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 160.01 | 09-DEC-14:00 | 62.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 11.29 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 116.75 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.42 | 04-JAN-13:00 | 116.75 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.16 | 28-FEB-15:00 | 29.70 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 19-MAR-16:00 | 20.47 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.80 | 04-APR-14:00 | 11.29 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.04 | 06-MAY-15:00 | 16.67 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 259.10 | 16-JUN-15:00 | 17.17 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 195.42 | 01-JUL-13:00 | 19.31 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 213.60 | 06-AUG-13:00 | 34.08 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.34 | 10-SEP-15:00 | 30.81 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.61 | 29-OCT-13:10 | 14.32 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 10-NOV-13:00 | 27.32 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 160.01 | 09-DEC-14:00 | 62.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 11.29 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 116.75 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.42 | 04-JAN-13:00 | 116.75 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.16 | 28-FEB-15:00 | 29.70 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 19-MAR-16:00 | 20.47 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.80 | 04-APR-14:00 | 11.29 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.04 | 06-MAY-15:00 | 16.67 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 259.10 | 16-JUN-15:00 | 17.17 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 195.42 | 01-JUL-13:00 | 19.31 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 213.60 | 06-AUG-13:00 | 34.08 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.34 | 10-SEP-15:00 | 30.81 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.61 | 29-OCT-13:10 | 14.32 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 10-NOV-13:00 | 27.32 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 160.01 | 09-DEC-14:00 | 62.01 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 137.29 | 11.29 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 310.00 | 116.75 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 356.98 | 04-JAN-13:00 | 261.33 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 481.09 | 28-FEB-15:00 | 66.02 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 19-MAR-16:00 | 45.78 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.36 | 04-APR-14:00 | 25.64 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 636.31 | 06-MAY-15:00 | 38.89 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 565.38 | 16-JUN-15:00 | 39.12 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 426.58 | 01-JUL-13:00 | 44.39 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.89 | 06-AUG-13:00 | 76.20 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 10-SEP-15:00 | 70.19 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 448.57 | 29-OCT-13:10 | 32.23 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 10-NOV-13:00 | 60.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 348.92 | 09-DEC-14:00 | 134.41 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 25.64 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 261.33 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 356.98 | 04-JAN-13:00 | 261.33 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 481.09 | 28-FEB-15:00 | 66.02 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 19-MAR-16:00 | 45.78 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.36 | 04-APR-14:00 | 25.64 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 636.20 | 06-MAY-15:00 | 38.89 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 565.38 | 16-JUN-15:00 | 39.12 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 426.58 | 01-JUL-13:00 | 44.39 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.89 | 06-AUG-13:00 | 76.20 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 10-SEP-15:00 | 70.19 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 448.57 | 29-OCT-13:10 | 32.23 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 10-NOV-13:00 | 60.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 348.92 | 09-DEC-14:00 | 132.59 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 25.64 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 261.33 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 356.98 | 04-JAN-13:00 | 261.33 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 481.09 | 28-FEB-15:00 | 66.02 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 19-MAR-16:00 | 45.78 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.36 | 04-APR-14:00 | 25.64 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 636.31 | 06-MAY-15:00 | 38.89 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 565.38 | 16-JUN-15:00 | 39.12 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 426.58 | 01-JUL-13:00 | 44.39 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.89 | 06-AUG-13:00 | 76.20 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 10-SEP-15:00 | 70.19 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 448.57 | 29-OCT-13:10 | 32.23 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 10-NOV-13:00 | 60.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 348.92 | 09-DEC-14:00 | 134.05 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 25.64 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 261.33 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 356.98 | 04-JAN-13:00 | 261.33 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 481.09 | 28-FEB-15:00 | 66.02 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 19-MAR-16:00 | 45.78 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.36 | 04-APR-14:00 | 25.64 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 636.22 | 06-MAY-15:00 | 38.89 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 565.38 | 16-JUN-15:00 | 39.12 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 426.58 | 01-JUL-13:00 | 44.39 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.89 | 06-AUG-13:00 | 76.20 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 10-SEP-15:00 | 70.19 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 448.57 | 29-OCT-13:10 | 32.23 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 10-NOV-13:00 | 60.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 348.92 | 09-DEC-14:00 | 132.20 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 299.38 | 25.64 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 677.31 | 261.33 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 215.32 | 04-JAN-13:00 | 157.63 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 290.18 | 28-FEB-15:00 | 39.82 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 19-MAR-16:00 | 27.61 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.25 | 04-APR-14:00 | 15.47 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 383.80 | 06-MAY-15:00 | 23.46 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 341.03 | 16-JUN-15:00 | 23.60 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 257.30 | 01-JUL-13:00 | 26.77 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 281.01 | 06-AUG-13:00 | 45.96 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 308.45 | 10-SEP-15:00 | 42.33 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.57 | 29-OCT-13:10 | 19.44 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 10-NOV-13:00 | 36.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.46 | 09-DEC-14:00 | 82.57 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 15.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 157.63 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 215.32 | 04-JAN-13:00 | 157.63 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 290.18 | 28-FEB-15:00 | 39.82 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 19-MAR-16:00 | 27.61 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.25 | 04-APR-14:00 | 15.47 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 383.80 | 06-MAY-15:00 | 23.46 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 341.03 | 16-JUN-15:00 | 23.60 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 257.30 | 01-JUL-13:00 | 26.77 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 281.01 | 06-AUG-13:00 | 45.96 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 308.45 | 10-SEP-15:00 | 42.33 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.57 | 29-OCT-13:10 | 19.44 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 10-NOV-13:00 | 36.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.46 | 09-DEC-14:00 | 82.57 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 15.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 157.63 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 215.32 | 04-JAN-13:00 | 157.63 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 290.18 | 28-FEB-15:00 | 39.82 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 19-MAR-16:00 | 27.61 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.25 | 04-APR-14:00 | 15.47 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 383.80 | 06-MAY-15:00 | 23.46 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 341.03 | 16-JUN-15:00 | 23.60 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 257.30 | 01-JUL-13:00 | 26.77 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 281.01 | 06-AUG-13:00 | 45.96 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 308.45 | 10-SEP-15:00 | 42.33 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.57 | 29-OCT-13:10 | 19.44 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 10-NOV-13:00 | 36.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.46 | 09-DEC-14:00 | 82.57 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 15.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 157.63 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 215.32 | 04-JAN-13:00 | 157.63 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 290.18 | 28-FEB-15:00 | 39.82 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 19-MAR-16:00 | 27.61 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.25 | 04-APR-14:00 | 15.47 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 383.80 | 06-MAY-15:00 | 23.46 | 08-MAY-22:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 341.03 | 16-JUN-15:00 | 23.60 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 257.30 | 01-JUL-13:00 | 26.77 | 03-JUL-13:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 281.01 | 06-AUG-13:00 | 45.96 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 308.45 | 10-SEP-15:00 | 42.33 | 15-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.57 | 29-OCT-13:10 | 19.44 | 23-OCT-05:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 10-NOV-13:00 | 36.49 | 25-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.46 | 09-DEC-14:00 | 82.57 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 180.58 | 15.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 408.53 | 157.63 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.53 | 04-JAN-13:00 | 77.37 | 07-JAN-05:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.61 | 28-FEB-15:00 | 18.10 | 01-FEB-07:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.60 | 19-MAR-16:00 | 17.75 | 14-MAR-22:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.40 | 04-APR-14:00 | 13.01 | 14-APR-16:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.83 | 06-MAY-15:00 | 32.64 | 08-MAY-22:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.24 | 16-JUN-14:30 | 32.77 | 20-JUN-23:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.53 | 01-JUL-13:00 | 32.14 | 03-JUL-13:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.25 | 06-AUG-13:00 | 34.13 | 23-AUG-20:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.53 | 10-SEP-15:00 | 42.78 | 15-SEP-16:53 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.43 | 29-OCT-13:00 | 15.31 | 30-OCT-16:25 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.08 | 10-NOV-12:00 | 14.57 | 25-NOV-05:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.55 | 09-DEC-14:00 | 28.11 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.08 | 13.01 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.83 | 77.37 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2098.39 | 03-JAN-17:01 | 3540.97 | 24-JAN-07:02 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2500.85 | 24-FEB-17:02 | 2741.45 | 02-FEB-07:02 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3048.32 | 19-MAR-16:02 | 1673.66 | 15-MAR-06:03 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3274.14 | 11-APR-16:01 | 1402.25 | 14-APR-16:03 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3564.11 | 05-MAY-16:01 | 1468.03 | 09-MAY-06:03 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3534.98 | 12-JUN-16:01 | 1681.14 | 21-JUN-06:03 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2631.75 | 15-JUL-16:02 | 1380.06 | 22-JUL-06:03 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2449.37 | 01-AUG-16:02 | 1614.24 | 20-AUG-06:03 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2435.92 | 04-SEP-16:03 | 1615.79 | 14-SEP-16:02 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1889.62 | 04-OCT-16:02 | 1644.66 | 23-OCT-06:03 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1580.78 | 03-NOV-16:02 | 2725.55 | 25-NOV-07:02 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1596.16 | 13-DEC-17:02 | 3800.14 | 21-DEC-07:02 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 1580.78 | 1380.06 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 3564.11 | 3800.14 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.85 | 04-JAN-13:00 | 65.72 | 07-JAN-05:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.06 | 28-FEB-15:00 | 14.56 | 01-FEB-07:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.34 | 19-MAR-16:00 | 12.44 | 14-MAR-22:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.90 | 04-APR-14:00 | 9.20 | 14-APR-16:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.61 | 06-MAY-15:00 | 22.00 | 08-MAY-22:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.16 | 16-JUN-14:40 | 21.32 | 20-JUN-23:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.20 | 01-JUL-13:00 | 20.27 | 03-JUL-13:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.74 | 12-AUG-12:00 | 22.19 | 23-AUG-20:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.03 | 10-SEP-15:00 | 27.26 | 15-SEP-16:53 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.05 | 29-OCT-13:00 | 11.38 | 30-OCT-16:50 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 10-NOV-12:20 | 11.70 | 25-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.78 | 09-DEC-14:00 | 23.09 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 9.20 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.34 | 65.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2398.67 | 31-JAN-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 139.04 | 0.00 |
| February | 2372.26 | 28-FEB-15:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 246.72 | 0.00 |
| March | 2528.93 | 19-MAR-15:40 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 334.71 | 0.00 |
| April | 2304.87 | 02-APR-16:02 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 175.61 | 0.00 |
| May | 2408.78 | 06-MAY-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 303.62 | 0.00 |
| June | 2288.77 | 16-JUN-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 267.68 | 0.00 |
| July | 2100.16 | 04-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 167.63 | 0.00 |
| August | 2158.04 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 154.51 | 0.00 |
| September | 2138.44 | 10-SEP-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 221.32 | 0.00 |
| October | 2197.99 | 28-OCT-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 40.49 | 0.00 |
| November | 2242.63 | 19-NOV-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 87.44 | 0.00 |
| December | 2304.26 | 07-DEC-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 59.43 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2100.16 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 40.49 | 0.00 | |
| Maximum of Months | 2528.93 | 1187.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 334.71 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1882.37 | 31-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 139.04 | 0.00 |
| February | 2025.99 | 28-FEB-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 209.57 | 0.00 |
| March | 2297.46 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 337.35 | 0.00 |
| April | 2232.79 | 11-APR-16:10 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 185.97 | 0.00 |
| May | 2560.32 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 319.75 | 0.00 |
| June | 2625.87 | 16-JUN-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 267.68 | 0.00 |
| July | 2300.23 | 14-JUL-17:17 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 46.06 | 0.00 |
| August | 2235.67 | 01-AUG-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 144.01 | 0.00 |
| September | 2109.76 | 02-SEP-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 113.26 | 0.00 |
| October | 2034.22 | 04-OCT-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 139.72 | 0.00 |
| November | 1873.85 | 04-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 100.79 | 0.00 |
| December | 1744.31 | 07-DEC-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 73.73 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1744.31 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 46.06 | 0.00 | |
| Maximum of Months | 2625.87 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 337.35 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5990.77 | 23-JAN-08:62 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.13 |
| February | 5682.63 | 24-FEB-08:62 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.82 |
| March | 5256.43 | 03-MAR-08:62 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.28 |
| April | 4502.96 | 03-APR-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 47.96 | 0.00 |
| May | 4427.22 | 30-MAY-08:20 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 7.94 | 0.00 |
| June | 4389.43 | 12-JUN-08:50 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 124.38 | 0.00 |
| July | 4743.68 | 17-JUL-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 3.13 | 0.00 |
| August | 4395.49 | 28-AUG-08:63 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 22.19 | 0.00 |
| September | 4433.84 | 05-SEP-08:63 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 24.23 | 0.00 |
| October | 4662.31 | 10-OCT-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2.09 | 0.00 |
| November | 5158.08 | 24-NOV-09:02 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 29.02 | 0.00 |
| December | 5611.10 | 21-DEC-08:62 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.22 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4389.43 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5990.77 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 124.38 | 61.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1721.27 | 04-JAN-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 188.90 | 0.00 |
| February | 1843.57 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 250.79 | 0.00 |
| March | 2068.08 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 337.35 | 0.00 |
| April | 1997.11 | 30-APR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 175.85 | 0.00 |
| May | 2369.41 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 319.75 | 0.00 |
| June | 2382.70 | 16-JUN-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 267.68 | 0.00 |
| July | 2022.64 | 05-JUL-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 174.52 | 0.00 |
| August | 2038.45 | 09-AUG-16:08 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 190.95 | 0.00 |
| September | 1894.28 | 10-SEP-15:00 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 271.02 | 0.00 |
| October | 1758.46 | 29-OCT-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 237.45 | 0.00 |
| November | 1632.11 | 10-NOV-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 0.00 |
| December | 1621.74 | 09-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 185.12 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1621.74 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 0.00 | |
| Maximum of Months | 2382.70 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 337.35 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1311.53 | 05-JAN-17:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 62.17 | 0.00 |
| February | 1377.48 | 28-FEB-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 126.41 | 0.00 |
| March | 1577.89 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
| April | 1568.99 | 30-APR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 106.07 | 0.00 |
| May | 1800.48 | 06-MAY-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 134.61 | 0.00 |
| June | 1903.94 | 16-JUN-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 161.46 | 0.00 |
| July | 1668.62 | 14-JUL-17:17 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 27.78 | 0.00 |
| August | 1629.12 | 01-AUG-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.72 | 0.00 |
| September | 1471.29 | 02-SEP-17:10 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 62.63 | 0.00 |
| October | 1394.59 | 04-OCT-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 84.28 | 0.00 |
| November | 1321.44 | 04-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 60.79 | 0.00 |
| December | 1268.85 | 09-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 111.66 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1268.85 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 27.78 | 0.00 | |
| Maximum of Months | 1903.94 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1307.67 | 05-JAN-17:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 62.17 | 0.00 |
| February | 1376.25 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 151.27 | 0.00 |
| March | 1574.40 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
| April | 1566.32 | 30-APR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 106.07 | 0.00 |
| May | 1797.59 | 06-MAY-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 134.61 | 0.00 |
| June | 1900.74 | 16-JUN-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 161.46 | 0.00 |
| July | 1664.52 | 14-JUL-17:17 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 27.78 | 0.00 |
| August | 1626.69 | 01-AUG-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.72 | 0.00 |
| September | 1468.10 | 02-SEP-17:10 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 62.63 | 0.00 |
| October | 1390.58 | 04-OCT-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 84.28 | 0.00 |
| November | 1316.32 | 04-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 60.79 | 0.00 |
| December | 1268.94 | 09-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 111.66 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1268.94 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 27.78 | 0.00 | |
| Maximum of Months | 1900.74 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1861.13 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 113.94 | 0.00 |
| February | 1754.56 | 21-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 114.53 | 0.00 |
| March | 1810.89 | 19-MAR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
| April | 1597.71 | 02-APR-16:02 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 105.93 | 0.00 |
| May | 1655.57 | 06-MAY-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 134.61 | 0.00 |
| June | 1591.50 | 11-JUN-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 92.15 | 0.00 |
| July | 1489.67 | 15-JUL-17:07 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 41.90 | 0.00 |
| August | 1514.41 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 93.20 | 0.00 |
| September | 1511.53 | 04-SEP-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.00 | 0.00 |
| October | 1679.36 | 29-OCT-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 143.22 | 0.00 |
| November | 1769.46 | 19-NOV-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 63.46 | 0.00 |
| December | 1826.80 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 61.01 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1489.67 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 41.90 | 0.00 | |
| Maximum of Months | 1861.13 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1966.93 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 113.94 | 0.00 |
| February | 1896.08 | 20-FEB-16:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 113.69 | 0.00 |
| March | 1965.64 | 19-MAR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
| April | 1750.81 | 02-APR-16:02 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 105.93 | 0.00 |
| May | 1795.32 | 06-MAY-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 134.61 | 0.00 |
| June | 1748.46 | 11-JUN-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 92.15 | 0.00 |
| July | 1630.12 | 30-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 79.23 | 0.00 |
| August | 1664.71 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 93.20 | 0.00 |
| September | 1676.27 | 04-SEP-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.00 | 0.00 |
| October | 1832.84 | 29-OCT-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 143.22 | 0.00 |
| November | 1924.37 | 19-NOV-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 63.46 | 0.00 |
| December | 1932.59 | 31-DEC-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 54.67 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1630.12 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 54.67 | 0.00 | |
| Maximum of Months | 1966.93 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 203.48 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2641.72 | 31-JAN-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 199.31 | 0.00 |
| February | 2612.14 | 28-FEB-15:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 353.87 | 0.00 |
| March | 2833.67 | 19-MAR-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 462.94 | 0.00 |
| April | 2510.82 | 02-APR-16:08 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 251.83 | 0.00 |
| May | 2627.12 | 06-MAY-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 435.62 | 0.00 |
| June | 2441.42 | 16-JUN-16:10 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 383.84 | 0.00 |
| July | 2239.85 | 04-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 240.23 | 0.00 |
| August | 2283.25 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 221.55 | 0.00 |
| September | 2282.81 | 10-SEP-15:00 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 0.00 |
| October | 2423.23 | 28-OCT-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 111.84 | 0.00 |
| November | 2425.30 | 19-NOV-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 125.34 | 0.00 |
| December | 2505.37 | 07-DEC-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 85.20 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2239.85 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 85.20 | 0.00 | |
| Maximum of Months | 2833.67 | 1187.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 462.94 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2047.12 | 31-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 199.31 | 0.00 |
| February | 2203.24 | 28-FEB-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 300.45 | 0.00 |
| March | 2533.10 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 483.86 | 0.00 |
| April | 2448.58 | 11-APR-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 266.74 | 0.00 |
| May | 2779.97 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 458.78 | 0.00 |
| June | 2826.78 | 16-JUN-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 383.84 | 0.00 |
| July | 2453.75 | 04-JUL-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 229.28 | 0.00 |
| August | 2360.77 | 01-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 201.85 | 0.00 |
| September | 2218.39 | 02-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 166.64 | 0.00 |
| October | 2201.54 | 04-OCT-16:20 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 200.24 | 0.00 |
| November | 1980.50 | 04-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 144.33 | 0.00 |
| December | 1843.26 | 07-DEC-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 105.63 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1843.26 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 105.63 | 0.00 | |
| Maximum of Months | 2826.78 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 483.86 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2533.89 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 270.93 | 0.00 |
| February | 2383.42 | 28-FEB-15:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 365.01 | 0.00 |
| March | 2498.45 | 19-MAR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 483.86 | 0.00 |
| April | 2156.97 | 01-APR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 264.71 | 0.00 |
| May | 2352.49 | 06-MAY-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 458.78 | 0.00 |
| June | 2133.73 | 16-JUN-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 426.96 | 0.00 |
| July | 1914.22 | 29-JUL-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 235.80 | 0.00 |
| August | 1969.26 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 221.55 | 0.00 |
| September | 2031.25 | 10-SEP-15:00 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 0.00 |
| October | 2288.05 | 29-OCT-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 340.38 | 0.00 |
| November | 2307.11 | 18-NOV-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 165.61 | 0.00 |
| December | 2361.87 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 145.05 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1914.22 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 145.05 | 0.00 | |
| Maximum of Months | 2533.89 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 483.86 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1822.89 | 04-JAN-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 270.93 | 0.00 |
| February | 1964.05 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 359.73 | 0.00 |
| March | 2237.80 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 483.86 | 0.00 |
| April | 2086.30 | 11-APR-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 266.74 | 0.00 |
| May | 2508.23 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 458.78 | 0.00 |
| June | 2498.37 | 16-JUN-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 383.84 | 0.00 |
| July | 2121.27 | 13-JUL-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 262.31 | 0.00 |
| August | 2111.09 | 01-AUG-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 272.14 | 0.00 |
| September | 1964.87 | 10-SEP-15:00 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 388.52 | 0.00 |
| October | 1876.67 | 29-OCT-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 340.38 | 0.00 |
| November | 1715.45 | 10-NOV-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 0.00 |
| December | 1683.89 | 09-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 265.28 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1683.89 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 227.61 | 0.00 | |
| Maximum of Months | 2508.23 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 483.86 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1319.45 | 05-JAN-17:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 89.07 | 0.00 |
| February | 1420.57 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 216.98 | 0.00 |
| March | 1656.40 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
| April | 1599.20 | 30-APR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 152.06 | 0.00 |
| May | 1850.66 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 276.72 | 0.00 |
| June | 1959.48 | 16-JUN-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 231.52 | 0.00 |
| July | 1692.49 | 04-JUL-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 144.90 | 0.00 |
| August | 1641.53 | 01-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 121.75 | 0.00 |
| September | 1457.95 | 02-SEP-16:15 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 101.73 | 0.00 |
| October | 1417.16 | 04-OCT-16:20 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 120.78 | 0.00 |
| November | 1328.14 | 04-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 87.05 | 0.00 |
| December | 1288.02 | 09-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 160.01 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1288.02 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 87.05 | 0.00 | |
| Maximum of Months | 1959.48 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1315.72 | 03-JAN-17:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 87.41 | 0.00 |
| February | 1419.98 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 216.98 | 0.00 |
| March | 1652.33 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
| April | 1596.06 | 30-APR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 152.06 | 0.00 |
| May | 1849.35 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 276.72 | 0.00 |
| June | 1955.70 | 16-JUN-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 231.52 | 0.00 |
| July | 1687.47 | 04-JUL-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 144.90 | 0.00 |
| August | 1638.86 | 01-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 121.75 | 0.00 |
| September | 1455.17 | 02-SEP-16:15 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 101.73 | 0.00 |
| October | 1412.52 | 04-OCT-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 121.53 | 0.00 |
| November | 1322.56 | 04-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 87.05 | 0.00 |
| December | 1288.21 | 09-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 160.01 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1288.21 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 87.05 | 0.00 | |
| Maximum of Months | 1955.70 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2007.19 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 163.42 | 0.00 |
| February | 1859.36 | 04-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.89 | 0.00 |
| March | 1916.73 | 19-MAR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
| April | 1647.20 | 01-APR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 159.67 | 0.00 |
| May | 1695.27 | 06-MAY-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 276.72 | 0.00 |
| June | 1601.69 | 17-JUN-16:10 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 182.43 | 0.00 |
| July | 1494.46 | 29-JUL-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 142.23 | 0.00 |
| August | 1516.72 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 133.63 | 0.00 |
| September | 1521.61 | 24-SEP-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 111.69 | 0.00 |
| October | 1779.09 | 29-OCT-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 205.31 | 0.00 |
| November | 1876.82 | 18-NOV-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 99.89 | 0.00 |
| December | 1946.43 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 87.49 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1494.46 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.89 | 0.00 | |
| Maximum of Months | 2007.19 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2011.31 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 163.42 | 0.00 |
| February | 1861.96 | 04-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.89 | 0.00 |
| March | 1912.48 | 19-MAR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
| April | 1643.68 | 01-APR-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 159.67 | 0.00 |
| May | 1694.02 | 06-MAY-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 276.72 | 0.00 |
| June | 1599.20 | 17-JUN-16:10 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 182.43 | 0.00 |
| July | 1493.37 | 29-JUL-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 142.23 | 0.00 |
| August | 1513.11 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 133.63 | 0.00 |
| September | 1519.55 | 24-SEP-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 111.69 | 0.00 |
| October | 1780.51 | 29-OCT-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 205.31 | 0.00 |
| November | 1878.78 | 18-NOV-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 99.89 | 0.00 |
| December | 1947.18 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 87.49 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1493.37 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.89 | 0.00 | |
| Maximum of Months | 2011.31 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 291.85 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 3612.93 | 05-JAN-15:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 282.25 | 0.00 |
| February | 3657.43 | 21-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 358.74 | 0.00 |
| March | 3974.30 | 19-MAR-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 610.13 | 0.00 |
| April | 3473.68 | 02-APR-16:02 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 331.68 | 0.00 |
| May | 3711.95 | 06-MAY-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 574.37 | 0.00 |
| June | 3330.13 | 16-JUN-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 552.10 | 0.00 |
| July | 3051.45 | 04-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 316.01 | 0.00 |
| August | 3133.93 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 291.75 | 0.00 |
| September | 3232.06 | 10-SEP-15:00 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 0.00 |
| October | 3344.88 | 28-OCT-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 165.58 | 0.00 |
| November | 3368.09 | 19-NOV-14:10 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 187.13 | 0.00 |
| December | 3456.77 | 07-DEC-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 148.56 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3051.45 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 148.56 | 0.00 | |
| Maximum of Months | 3974.30 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 610.13 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2839.37 | 31-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 262.32 | 0.00 |
| February | 3112.21 | 28-FEB-15:20 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 466.27 | 0.00 |
| March | 3587.01 | 19-MAR-15:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 632.75 | 0.00 |
| April | 3443.50 | 11-APR-16:10 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 351.48 | 0.00 |
| May | 3911.46 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 604.85 | 0.00 |
| June | 3805.21 | 16-JUN-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 505.54 | 0.00 |
| July | 3332.75 | 04-JUL-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 316.01 | 0.00 |
| August | 3239.57 | 01-AUG-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 252.82 | 0.00 |
| September | 3147.35 | 10-SEP-15:00 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 0.00 |
| October | 3008.90 | 04-OCT-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 265.08 | 0.00 |
| November | 2647.98 | 04-NOV-15:20 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 210.36 | 0.00 |
| December | 2550.74 | 07-DEC-15:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 112.13 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2550.74 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 112.13 | 0.00 | |
| Maximum of Months | 3911.46 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 632.75 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 3509.99 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 356.98 | 0.00 |
| February | 3298.37 | 28-FEB-15:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 481.09 | 0.00 |
| March | 3437.50 | 19-MAR-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 610.13 | 0.00 |
| April | 2962.92 | 01-APR-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 316.35 | 0.00 |
| May | 3292.71 | 06-MAY-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 604.96 | 0.00 |
| June | 2994.95 | 16-JUN-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 527.39 | 0.00 |
| July | 2642.78 | 01-JUL-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 426.58 | 0.00 |
| August | 2750.99 | 27-AUG-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 353.07 | 0.00 |
| September | 2849.76 | 10-SEP-15:00 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 0.00 |
| October | 3097.36 | 29-OCT-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 447.98 | 0.00 |
| November | 3225.02 | 18-NOV-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 218.23 | 0.00 |
| December | 3268.74 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 191.02 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2642.78 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 191.02 | 0.00 | |
| Maximum of Months | 3509.99 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 610.13 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2569.07 | 04-JAN-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 356.98 | 0.00 |
| February | 2763.80 | 28-FEB-15:00 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 481.09 | 0.00 |
| March | 3057.05 | 19-MAR-15:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 632.75 | 0.00 |
| April | 2872.29 | 11-APR-16:10 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 351.48 | 0.00 |
| May | 3494.47 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 604.86 | 0.00 |
| June | 3426.28 | 16-JUN-14:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 527.39 | 0.00 |
| July | 2831.40 | 04-JUL-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 372.14 | 0.00 |
| August | 2936.96 | 01-AUG-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 358.38 | 0.00 |
| September | 2767.11 | 10-SEP-15:00 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 511.37 | 0.00 |
| October | 2589.64 | 29-OCT-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 447.98 | 0.00 |
| November | 2356.45 | 18-NOV-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 218.23 | 0.00 |
| December | 2285.12 | 07-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 191.02 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2285.12 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 191.02 | 0.00 | |
| Maximum of Months | 3494.47 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 632.75 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1923.64 | 03-JAN-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 211.92 | 0.00 |
| February | 2109.61 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 285.95 | 0.00 |
| March | 2372.33 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 384.56 | 0.00 |
| April | 2304.14 | 11-APR-16:10 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 212.00 | 0.00 |
| May | 2728.37 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 364.90 | 0.00 |
| June | 2724.16 | 16-JUN-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 339.02 | 0.00 |
| July | 2354.75 | 04-JUL-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 190.61 | 0.00 |
| August | 2331.34 | 01-AUG-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 216.16 | 0.00 |
| September | 2130.30 | 10-SEP-15:00 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 308.45 | 0.00 |
| October | 2021.60 | 04-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 193.16 | 0.00 |
| November | 1823.55 | 18-NOV-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 131.63 | 0.00 |
| December | 1793.81 | 30-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 103.06 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1793.81 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 103.06 | 0.00 | |
| Maximum of Months | 2728.37 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 384.56 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1926.09 | 03-JAN-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 211.92 | 0.00 |
| February | 2106.07 | 28-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 285.95 | 0.00 |
| March | 2361.11 | 19-MAR-16:10 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 384.56 | 0.00 |
| April | 2292.66 | 11-APR-16:10 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 212.00 | 0.00 |
| May | 2722.75 | 06-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 364.90 | 0.00 |
| June | 2719.50 | 16-JUN-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 339.02 | 0.00 |
| July | 2343.92 | 04-JUL-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 190.61 | 0.00 |
| August | 2328.76 | 01-AUG-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 216.16 | 0.00 |
| September | 2125.19 | 10-SEP-15:00 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 308.45 | 0.00 |
| October | 2015.47 | 04-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 193.16 | 0.00 |
| November | 1827.52 | 18-NOV-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 131.63 | 0.00 |
| December | 1794.90 | 30-DEC-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 103.06 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1794.90 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 103.06 | 0.00 | |
| Maximum of Months | 2722.75 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 384.56 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2859.06 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 215.32 | 0.00 |
| February | 2682.49 | 21-FEB-14:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 199.47 | 0.00 |
| March | 2735.63 | 19-MAR-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 368.02 | 0.00 |
| April | 2381.15 | 01-APR-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 210.36 | 0.00 |
| May | 2524.46 | 06-MAY-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 364.90 | 0.00 |
| June | 2270.89 | 16-JUN-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 318.11 | 0.00 |
| July | 2079.56 | 04-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 190.61 | 0.00 |
| August | 2151.85 | 27-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 175.97 | 0.00 |
| September | 2267.39 | 30-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 115.64 | 0.00 |
| October | 2547.69 | 28-OCT-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 76.52 | 0.00 |
| November | 2693.89 | 18-NOV-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 131.63 | 0.00 |
| December | 2773.51 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 115.22 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2079.56 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 76.52 | 0.00 | |
| Maximum of Months | 2859.06 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 368.02 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2866.70 | 04-JAN-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 215.32 | 0.00 |
| February | 2679.93 | 21-FEB-14:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 199.47 | 0.00 |
| March | 2726.87 | 19-MAR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 354.24 | 0.00 |
| April | 2371.10 | 01-APR-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 210.36 | 0.00 |
| May | 2518.96 | 06-MAY-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 364.90 | 0.00 |
| June | 2270.28 | 16-JUN-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 318.11 | 0.00 |
| July | 2068.85 | 04-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 190.61 | 0.00 |
| August | 2143.69 | 13-AUG-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 174.49 | 0.00 |
| September | 2265.36 | 30-SEP-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 115.24 | 0.00 |
| October | 2549.52 | 28-OCT-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 76.52 | 0.00 |
| November | 2697.61 | 18-NOV-13:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 131.63 | 0.00 |
| December | 2774.24 | 07-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 115.22 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2068.85 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 76.52 | 0.00 | |
| Maximum of Months | 2866.70 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 364.90 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.45 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.24 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.49 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.80 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.58 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.49 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.93 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.96 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.06 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.80 | 5.58 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.03 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.92 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.30 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 1.76 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 3.60 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.05 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.96 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.80 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.05 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.28 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 3.60 | 4.05 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.60 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.79 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.35 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.24 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.07 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.19 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.38 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.10 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.80 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.24 | 4.07 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.136456E+12 | 96315.44 | 03-JAN-17:40 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 0.127096E+12 | 98514.08 | 06-FEB-17:00 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 0.144911E+12 | 104759.52 | 19-MAR-16:10 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 0.145265E+12 | 103665.13 | 02-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 0.154325E+12 | 107146.98 | 06-MAY-16:19 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 0.150230E+12 | 106864.01 | 14-JUN-16:19 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 0.140601E+12 | 98685.13 | 26-JUL-16:19 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 0.145983E+12 | 103262.54 | 09-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 0.139455E+12 | 98204.85 | 04-SEP-17:40 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 0.140727E+12 | 98874.04 | 04-OCT-17:00 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 0.134719E+12 | 95929.26 | 19-NOV-18:19 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 0.135472E+12 | 97139.06 | 10-DEC-18:19 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.169524E+13 | 0.00 | ||||
| Minimum of Months | 0.127096E+12 | 95929.26 | 0.00 | 0.00 | ||
| Maximum of Months | 0.154325E+12 | 107146.98 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.446176E+10 | 0.389380E+11 | 0.00 | 0.143293E+11 | 0.00 | 0.00 | 0.413152E+11 | 0.00 | 0.00 | 0.00 | 0.290026E+11 | 0.00 |
| February | 0.760941E+10 | 0.396707E+10 | 0.351823E+11 | 0.00 | 0.136319E+11 | 0.00 | 0.00 | 0.406235E+11 | 0.00 | 0.00 | 0.00 | 0.260819E+11 | 0.00 |
| March | 0.845392E+10 | 0.425739E+10 | 0.389781E+11 | 0.00 | 0.158759E+11 | 0.00 | 0.00 | 0.487571E+11 | 0.00 | 0.00 | 0.00 | 0.285884E+11 | 0.00 |
| April | 0.814762E+10 | 0.402246E+10 | 0.376905E+11 | 0.00 | 0.163246E+11 | 0.00 | 0.00 | 0.518205E+11 | 0.00 | 0.00 | 0.00 | 0.272597E+11 | 0.00 |
| May | 0.843904E+10 | 0.408549E+10 | 0.389647E+11 | 0.00 | 0.177012E+11 | 0.00 | 0.00 | 0.573717E+11 | 0.00 | 0.00 | 0.00 | 0.277631E+11 | 0.00 |
| June | 0.817737E+10 | 0.390786E+10 | 0.377173E+11 | 0.00 | 0.173618E+11 | 0.00 | 0.00 | 0.564800E+11 | 0.00 | 0.00 | 0.00 | 0.265854E+11 | 0.00 |
| July | 0.840929E+10 | 0.407021E+10 | 0.389380E+11 | 0.00 | 0.154725E+11 | 0.00 | 0.00 | 0.463444E+11 | 0.00 | 0.00 | 0.00 | 0.273665E+11 | 0.00 |
| August | 0.845392E+10 | 0.412178E+10 | 0.389781E+11 | 0.00 | 0.163398E+11 | 0.00 | 0.00 | 0.505786E+11 | 0.00 | 0.00 | 0.00 | 0.275112E+11 | 0.00 |
| September | 0.814762E+10 | 0.409122E+10 | 0.376905E+11 | 0.00 | 0.154261E+11 | 0.00 | 0.00 | 0.471796E+11 | 0.00 | 0.00 | 0.00 | 0.269197E+11 | 0.00 |
| October | 0.842417E+10 | 0.433761E+10 | 0.389514E+11 | 0.00 | 0.152804E+11 | 0.00 | 0.00 | 0.454915E+11 | 0.00 | 0.00 | 0.00 | 0.282415E+11 | 0.00 |
| November | 0.814762E+10 | 0.428222E+10 | 0.376905E+11 | 0.00 | 0.144385E+11 | 0.00 | 0.00 | 0.424473E+11 | 0.00 | 0.00 | 0.00 | 0.277130E+11 | 0.00 |
| December | 0.840929E+10 | 0.449041E+10 | 0.389380E+11 | 0.00 | 0.141797E+11 | 0.00 | 0.00 | 0.405298E+11 | 0.00 | 0.00 | 0.00 | 0.289248E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.500954E+11 | 0.458657E+12 | 0.00 | 0.186362E+12 | 0.00 | 0.00 | 0.568939E+12 | 0.00 | 0.00 | 0.00 | 0.331958E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.390786E+10 | 0.351823E+11 | 0.00 | 0.136319E+11 | 0.00 | 0.00 | 0.405298E+11 | 0.00 | 0.00 | 0.00 | 0.260819E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.449041E+10 | 0.389781E+11 | 0.00 | 0.177012E+11 | 0.00 | 0.00 | 0.573717E+11 | 0.00 | 0.00 | 0.00 | 0.290026E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 7970.03 | 04-JAN-12:00 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 8391.06 | 28-FEB-14:00 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 8971.66 | 19-MAR-16:10 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 8775.99 | 02-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 9756.81 | 06-MAY-15:09 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 9577.52 | 13-JUN-15:09 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 8203.71 | 04-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 8801.81 | 13-AUG-15:09 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 8403.57 | 04-SEP-16:10 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 8464.25 | 29-OCT-12:00 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 7986.99 | 18-NOV-12:00 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 7641.42 | 30-DEC-13:00 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 7641.42 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 9756.81 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 29031.62 | 04-JAN-12:00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 36755.48 | 16-JAN-07:10 | 0.00 |
| February | 31241.17 | 28-FEB-14:00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 36750.45 | 01-FEB-07:19 | 0.00 |
| March | 32573.66 | 19-MAR-16:10 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 36733.79 | 01-MAR-07:00 | 0.00 |
| April | 31685.81 | 02-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 36701.22 | 02-APR-06:19 | 0.00 |
| May | 37152.74 | 06-MAY-15:09 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 36668.74 | 01-MAY-06:49 | 0.00 |
| June | 37533.67 | 13-JUN-15:09 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 36639.84 | 02-JUN-06:30 | 0.00 |
| July | 28669.43 | 28-JUL-12:00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 36629.38 | 31-JUL-06:10 | 0.00 |
| August | 32744.85 | 01-AUG-15:09 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 36645.40 | 29-AUG-06:10 | 0.00 |
| September | 30854.47 | 25-SEP-13:00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 36673.07 | 30-SEP-06:30 | 0.00 |
| October | 29985.38 | 29-OCT-12:00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 36706.26 | 30-OCT-06:19 | 0.00 |
| November | 28604.81 | 10-NOV-13:30 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 36734.89 | 28-NOV-07:10 | 0.00 |
| December | 26332.30 | 07-DEC-13:00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 36753.08 | 30-DEC-07:10 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 26332.30 | 0.00 | 0.00 | 0.00 | 36629.38 | 0.00 | |||
| Maximum of Months | 37533.67 | 0.00 | 0.00 | 0.00 | 36755.48 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 96315.44 | 03-JAN-17:40 | 4289.87 | 22709.69 | 3183.33 | 0.00 | 6926.40 | 0.00 | 0.00 | 22865.19 | 0.00 |
| February | 98514.08 | 06-FEB-17:00 | 4289.87 | 22709.69 | 3183.33 | 0.00 | 7261.48 | 0.00 | 0.00 | 24734.02 | 0.00 |
| March | 104759.52 | 19-MAR-16:10 | 4289.87 | 22609.62 | 0.00 | 0.00 | 8971.66 | 0.00 | 0.00 | 32573.66 | 0.00 |
| April | 103665.13 | 02-APR-16:10 | 4289.87 | 22609.62 | 0.00 | 0.00 | 8775.99 | 0.00 | 0.00 | 31685.81 | 0.00 |
| May | 107146.98 | 06-MAY-16:19 | 4289.87 | 22609.62 | 0.00 | 0.00 | 9363.85 | 0.00 | 0.00 | 34603.79 | 0.00 |
| June | 106864.01 | 14-JUN-16:19 | 4289.87 | 22709.69 | 0.00 | 0.00 | 9302.27 | 0.00 | 0.00 | 34308.93 | 0.00 |
| July | 98685.13 | 26-JUL-16:19 | 4289.87 | 22709.69 | 0.00 | 0.00 | 7918.29 | 0.00 | 0.00 | 27518.04 | 0.00 |
| August | 103262.54 | 09-AUG-16:10 | 4289.87 | 22709.69 | 0.00 | 0.00 | 8744.54 | 0.00 | 0.00 | 31262.64 | 0.00 |
| September | 98204.85 | 04-SEP-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7712.32 | 0.00 | 0.00 | 26202.09 | 0.00 |
| October | 98874.04 | 04-OCT-17:00 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 7351.83 | 0.00 | 0.00 | 24023.67 | 0.00 |
| November | 95929.26 | 19-NOV-18:19 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 6780.80 | 0.00 | 0.00 | 21608.81 | 0.00 |
| December | 97139.06 | 10-DEC-18:19 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 7008.22 | 0.00 | 0.00 | 22575.82 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 95929.26 | 4289.87 | 22609.62 | 0.00 | 0.00 | 6780.80 | 0.00 | 0.00 | 21608.81 | 0.00 | |
| Maximum of Months | 107146.98 | 5231.74 | 22709.69 | 3183.33 | 0.00 | 9363.85 | 0.00 | 0.00 | 34603.79 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.60 | 0.17 | 24.60 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 25.50 | 3.83 | 25.50 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 25.48 | 4.50 | 25.48 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 25.15 | 1.50 | 25.15 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 25.03 | 0.67 | 25.03 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.60 | 0.17 | 24.60 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.63 | 0.17 | 24.63 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 11.00 | 25.37 | 11.00 | 25.37 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 25.50 | 4.50 | 25.50 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 72.33 | 24.00 | 533.00 | 24.00 | 72.33 | 24.00 |
| February | 29.67 | 24.00 | 473.00 | 24.00 | 29.67 | 24.00 |
| March | 169.83 | 24.00 | 506.00 | 24.00 | 169.83 | 24.00 |
| April | 362.50 | 24.00 | 510.00 | 24.00 | 362.50 | 24.00 |
| May | 443.50 | 24.00 | 515.00 | 24.00 | 443.50 | 24.00 |
| June | 452.83 | 24.00 | 492.00 | 24.00 | 452.83 | 24.00 |
| July | 253.00 | 24.00 | 533.00 | 24.00 | 253.00 | 24.00 |
| August | 478.00 | 24.00 | 506.00 | 24.00 | 478.00 | 24.00 |
| September | 427.50 | 24.00 | 510.00 | 24.00 | 427.50 | 24.00 |
| October | 402.33 | 24.00 | 524.00 | 24.00 | 402.33 | 24.00 |
| November | 243.50 | 24.00 | 510.00 | 24.00 | 243.50 | 24.00 |
| December | 156.67 | 24.00 | 533.00 | 24.00 | 156.67 | 24.00 |
| Annual Sum or Average | 3491.67 | 24.00 | 6145.00 | 24.00 | 3491.67 | 24.00 |
| Minimum of Months | 29.67 | 24.00 | 473.00 | 24.00 | 29.67 | 24.00 |
| Maximum of Months | 478.00 | 24.00 | 533.00 | 24.00 | 478.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 124.33 | 24.00 | 744.00 | 24.00 | 124.33 | 24.00 |
| February | 66.83 | 24.00 | 672.00 | 24.00 | 66.83 | 24.00 |
| March | 206.67 | 24.00 | 744.00 | 24.00 | 206.67 | 24.00 |
| April | 408.17 | 24.00 | 720.00 | 24.00 | 408.17 | 24.00 |
| May | 584.83 | 24.00 | 744.00 | 24.00 | 584.83 | 24.00 |
| June | 534.83 | 24.00 | 720.00 | 24.00 | 534.83 | 24.00 |
| July | 221.83 | 24.00 | 744.00 | 24.00 | 221.83 | 24.00 |
| August | 674.17 | 24.00 | 744.00 | 24.00 | 674.17 | 24.00 |
| September | 584.00 | 24.00 | 720.00 | 24.00 | 584.00 | 24.00 |
| October | 602.67 | 24.00 | 744.00 | 24.00 | 602.67 | 24.00 |
| November | 373.67 | 24.00 | 720.00 | 24.00 | 373.67 | 24.00 |
| December | 252.83 | 24.00 | 744.00 | 24.00 | 252.83 | 24.00 |
| Annual Sum or Average | 4634.83 | 24.00 | 8760.00 | 24.00 | 4634.83 | 24.00 |
| Minimum of Months | 66.83 | 24.00 | 672.00 | 24.00 | 66.83 | 24.00 |
| Maximum of Months | 674.17 | 24.00 | 744.00 | 24.00 | 674.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 20.50 | 25.54 | 140.00 | 24.41 | 20.50 | 24.54 |
| February | 20.00 | 25.57 | 133.00 | 24.42 | 20.00 | 24.55 |
| March | 27.50 | 25.41 | 161.00 | 24.42 | 27.50 | 24.55 |
| April | 27.50 | 25.30 | 140.00 | 24.43 | 27.50 | 24.55 |
| May | 35.00 | 25.16 | 154.00 | 24.43 | 35.00 | 24.54 |
| June | 33.17 | 25.23 | 154.00 | 24.44 | 33.17 | 24.55 |
| July | 26.33 | 25.32 | 140.00 | 24.42 | 26.33 | 24.54 |
| August | 37.00 | 25.13 | 161.00 | 24.42 | 37.00 | 24.53 |
| September | 29.50 | 25.21 | 140.00 | 24.42 | 29.50 | 24.54 |
| October | 30.33 | 25.23 | 147.00 | 24.42 | 30.33 | 24.54 |
| November | 25.33 | 25.37 | 140.00 | 24.42 | 25.33 | 24.55 |
| December | 20.67 | 25.52 | 140.00 | 24.41 | 20.67 | 24.54 |
| Annual Sum or Average | 332.83 | 25.31 | 1750.00 | 24.42 | 332.83 | 24.54 |
| Minimum of Months | 20.00 | 25.13 | 133.00 | 24.41 | 20.00 | 24.53 |
| Maximum of Months | 37.00 | 25.57 | 161.00 | 24.44 | 37.00 | 24.55 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 113.67 | 24.00 | 744.00 | 24.00 | 113.67 | 24.00 |
| February | 59.50 | 24.00 | 672.00 | 24.00 | 59.50 | 24.00 |
| March | 198.67 | 24.00 | 744.00 | 24.00 | 198.67 | 24.00 |
| April | 388.50 | 24.00 | 720.00 | 24.00 | 388.50 | 24.00 |
| May | 574.83 | 24.00 | 744.00 | 24.00 | 574.83 | 24.00 |
| June | 507.67 | 24.00 | 720.00 | 24.00 | 507.67 | 24.00 |
| July | 195.17 | 24.00 | 744.00 | 24.00 | 195.17 | 24.00 |
| August | 673.17 | 24.00 | 744.00 | 24.00 | 673.17 | 24.00 |
| September | 555.67 | 24.00 | 720.00 | 24.00 | 555.67 | 24.00 |
| October | 599.83 | 24.00 | 744.00 | 24.00 | 599.83 | 24.00 |
| November | 366.67 | 24.00 | 720.00 | 24.00 | 366.67 | 24.00 |
| December | 248.67 | 24.00 | 744.00 | 24.00 | 248.67 | 24.00 |
| Annual Sum or Average | 4482.00 | 24.00 | 8760.00 | 24.00 | 4482.00 | 24.00 |
| Minimum of Months | 59.50 | 24.00 | 672.00 | 24.00 | 59.50 | 24.00 |
| Maximum of Months | 673.17 | 24.00 | 744.00 | 24.00 | 673.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 137.33 | 24.00 | 744.00 | 24.00 | 137.33 | 24.00 |
| February | 83.33 | 24.00 | 672.00 | 24.00 | 83.33 | 24.00 |
| March | 214.50 | 24.00 | 744.00 | 24.00 | 214.50 | 24.00 |
| April | 459.83 | 24.00 | 720.00 | 24.00 | 459.83 | 24.00 |
| May | 616.17 | 24.00 | 744.00 | 24.00 | 616.17 | 24.00 |
| June | 602.50 | 24.00 | 720.00 | 24.00 | 602.50 | 24.00 |
| July | 289.83 | 24.00 | 744.00 | 24.00 | 289.83 | 24.00 |
| August | 731.33 | 24.00 | 744.00 | 24.00 | 731.33 | 24.00 |
| September | 655.17 | 24.00 | 720.00 | 24.00 | 655.17 | 24.00 |
| October | 693.83 | 24.00 | 744.00 | 24.00 | 693.83 | 24.00 |
| November | 440.67 | 24.00 | 720.00 | 24.00 | 440.67 | 24.00 |
| December | 287.50 | 24.00 | 744.00 | 24.00 | 287.50 | 24.00 |
| Annual Sum or Average | 5212.00 | 24.00 | 8760.00 | 24.00 | 5212.00 | 24.00 |
| Minimum of Months | 83.33 | 24.00 | 672.00 | 24.00 | 83.33 | 24.00 |
| Maximum of Months | 731.33 | 24.00 | 744.00 | 24.00 | 731.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 137.33 | 24.00 | 744.00 | 24.00 | 137.33 | 24.00 |
| February | 82.83 | 24.00 | 672.00 | 24.00 | 82.83 | 24.00 |
| March | 214.83 | 24.00 | 744.00 | 24.00 | 214.83 | 24.00 |
| April | 460.00 | 24.00 | 720.00 | 24.00 | 460.00 | 24.00 |
| May | 616.00 | 24.00 | 744.00 | 24.00 | 616.00 | 24.00 |
| June | 600.33 | 24.00 | 720.00 | 24.00 | 600.33 | 24.00 |
| July | 289.33 | 24.00 | 744.00 | 24.00 | 289.33 | 24.00 |
| August | 730.67 | 24.00 | 744.00 | 24.00 | 730.67 | 24.00 |
| September | 655.00 | 24.00 | 720.00 | 24.00 | 655.00 | 24.00 |
| October | 693.33 | 24.00 | 744.00 | 24.00 | 693.33 | 24.00 |
| November | 441.17 | 24.00 | 720.00 | 24.00 | 441.17 | 24.00 |
| December | 286.83 | 24.00 | 744.00 | 24.00 | 286.83 | 24.00 |
| Annual Sum or Average | 5207.67 | 24.00 | 8760.00 | 24.00 | 5207.67 | 24.00 |
| Minimum of Months | 82.83 | 24.00 | 672.00 | 24.00 | 82.83 | 24.00 |
| Maximum of Months | 730.67 | 24.00 | 744.00 | 24.00 | 730.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 65.50 | 24.00 | 533.00 | 24.00 | 65.50 | 24.00 |
| February | 28.50 | 24.00 | 473.00 | 24.00 | 28.50 | 24.00 |
| March | 168.50 | 24.00 | 506.00 | 24.00 | 168.50 | 24.00 |
| April | 394.33 | 24.00 | 510.00 | 24.00 | 394.33 | 24.00 |
| May | 461.33 | 24.00 | 515.00 | 24.00 | 461.33 | 24.00 |
| June | 479.83 | 24.00 | 492.00 | 24.00 | 479.83 | 24.00 |
| July | 300.17 | 24.00 | 533.00 | 24.00 | 300.17 | 24.00 |
| August | 502.67 | 24.00 | 506.00 | 24.00 | 502.67 | 24.00 |
| September | 465.00 | 24.00 | 510.00 | 24.00 | 465.00 | 24.00 |
| October | 440.50 | 24.00 | 524.00 | 24.00 | 440.50 | 24.00 |
| November | 244.00 | 24.00 | 510.00 | 24.00 | 244.00 | 24.00 |
| December | 156.17 | 24.00 | 533.00 | 24.00 | 156.17 | 24.00 |
| Annual Sum or Average | 3706.50 | 24.00 | 6145.00 | 24.00 | 3706.50 | 24.00 |
| Minimum of Months | 28.50 | 24.00 | 473.00 | 24.00 | 28.50 | 24.00 |
| Maximum of Months | 502.67 | 24.00 | 533.00 | 24.00 | 502.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 31.00 | 24.00 | 533.00 | 24.00 | 31.00 | 24.00 |
| February | 4.17 | 24.00 | 473.00 | 24.00 | 4.17 | 24.00 |
| March | 103.83 | 24.00 | 506.00 | 24.00 | 103.83 | 24.00 |
| April | 339.50 | 24.00 | 510.00 | 24.00 | 339.50 | 24.00 |
| May | 441.17 | 24.00 | 515.00 | 24.00 | 441.17 | 24.00 |
| June | 459.50 | 24.00 | 492.00 | 24.00 | 459.50 | 24.00 |
| July | 181.17 | 24.00 | 533.00 | 24.00 | 181.17 | 24.00 |
| August | 490.67 | 24.00 | 506.00 | 24.00 | 490.67 | 24.00 |
| September | 423.50 | 24.00 | 510.00 | 24.00 | 423.50 | 24.00 |
| October | 353.33 | 24.00 | 524.00 | 24.00 | 353.33 | 24.00 |
| November | 174.83 | 24.00 | 510.00 | 24.00 | 174.83 | 24.00 |
| December | 85.83 | 24.00 | 533.00 | 24.00 | 85.83 | 24.00 |
| Annual Sum or Average | 3088.50 | 24.00 | 6145.00 | 24.00 | 3088.50 | 24.00 |
| Minimum of Months | 4.17 | 24.00 | 473.00 | 24.00 | 4.17 | 24.00 |
| Maximum of Months | 490.67 | 24.00 | 533.00 | 24.00 | 490.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 131.83 | 24.00 | 533.00 | 24.00 | 131.83 | 24.00 |
| February | 81.50 | 24.00 | 473.00 | 24.00 | 81.50 | 24.00 |
| March | 238.00 | 24.00 | 506.00 | 24.00 | 238.00 | 24.00 |
| April | 408.17 | 24.00 | 510.00 | 24.00 | 408.17 | 24.00 |
| May | 463.50 | 24.00 | 515.00 | 24.00 | 463.50 | 24.00 |
| June | 474.33 | 24.00 | 492.00 | 24.00 | 474.33 | 24.00 |
| July | 344.33 | 24.00 | 533.00 | 24.00 | 344.33 | 24.00 |
| August | 495.00 | 24.00 | 506.00 | 24.00 | 495.00 | 24.00 |
| September | 462.00 | 24.00 | 510.00 | 24.00 | 462.00 | 24.00 |
| October | 450.00 | 24.00 | 524.00 | 24.00 | 450.00 | 24.00 |
| November | 324.83 | 24.00 | 510.00 | 24.00 | 324.83 | 24.00 |
| December | 231.67 | 24.00 | 533.00 | 24.00 | 231.67 | 24.00 |
| Annual Sum or Average | 4105.17 | 24.00 | 6145.00 | 24.00 | 4105.17 | 24.00 |
| Minimum of Months | 81.50 | 24.00 | 473.00 | 24.00 | 81.50 | 24.00 |
| Maximum of Months | 495.00 | 24.00 | 533.00 | 24.00 | 495.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 216.67 | 24.00 | 744.00 | 24.00 | 216.67 | 24.00 |
| February | 142.67 | 24.00 | 672.00 | 24.00 | 142.67 | 24.00 |
| March | 295.17 | 24.00 | 744.00 | 24.00 | 295.17 | 24.00 |
| April | 481.50 | 24.00 | 720.00 | 24.00 | 481.50 | 24.00 |
| May | 628.33 | 24.00 | 744.00 | 24.00 | 628.33 | 24.00 |
| June | 618.67 | 24.00 | 720.00 | 24.00 | 618.67 | 24.00 |
| July | 389.67 | 24.00 | 744.00 | 24.00 | 389.67 | 24.00 |
| August | 719.00 | 24.00 | 744.00 | 24.00 | 719.00 | 24.00 |
| September | 642.83 | 24.00 | 720.00 | 24.00 | 642.83 | 24.00 |
| October | 673.33 | 24.00 | 744.00 | 24.00 | 673.33 | 24.00 |
| November | 463.17 | 24.00 | 720.00 | 24.00 | 463.17 | 24.00 |
| December | 334.17 | 24.00 | 744.00 | 24.00 | 334.17 | 24.00 |
| Annual Sum or Average | 5605.17 | 24.00 | 8760.00 | 24.00 | 5605.17 | 24.00 |
| Minimum of Months | 142.67 | 24.00 | 672.00 | 24.00 | 142.67 | 24.00 |
| Maximum of Months | 719.00 | 24.00 | 744.00 | 24.00 | 719.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 123.50 | 24.00 | 533.00 | 24.00 | 123.50 | 24.00 |
| February | 70.33 | 24.00 | 473.00 | 24.00 | 70.33 | 24.00 |
| March | 238.83 | 24.00 | 506.00 | 24.00 | 238.83 | 24.00 |
| April | 413.33 | 24.00 | 510.00 | 24.00 | 413.33 | 24.00 |
| May | 457.83 | 24.00 | 515.00 | 24.00 | 457.83 | 24.00 |
| June | 481.50 | 24.00 | 492.00 | 24.00 | 481.50 | 24.00 |
| July | 342.17 | 24.00 | 533.00 | 24.00 | 342.17 | 24.00 |
| August | 503.00 | 24.00 | 506.00 | 24.00 | 503.00 | 24.00 |
| September | 473.33 | 24.00 | 510.00 | 24.00 | 473.33 | 24.00 |
| October | 453.83 | 24.00 | 524.00 | 24.00 | 453.83 | 24.00 |
| November | 319.17 | 24.00 | 510.00 | 24.00 | 319.17 | 24.00 |
| December | 225.67 | 24.00 | 533.00 | 24.00 | 225.67 | 24.00 |
| Annual Sum or Average | 4102.50 | 24.00 | 6145.00 | 24.00 | 4102.50 | 24.00 |
| Minimum of Months | 70.33 | 24.00 | 473.00 | 24.00 | 70.33 | 24.00 |
| Maximum of Months | 503.00 | 24.00 | 533.00 | 24.00 | 503.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 202.50 | 24.00 | 744.00 | 24.00 | 202.50 | 24.00 |
| February | 135.83 | 24.00 | 672.00 | 24.00 | 135.83 | 24.00 |
| March | 284.00 | 24.00 | 744.00 | 24.00 | 284.00 | 24.00 |
| April | 462.33 | 24.00 | 720.00 | 24.00 | 462.33 | 24.00 |
| May | 618.83 | 24.00 | 744.00 | 24.00 | 618.83 | 24.00 |
| June | 596.00 | 24.00 | 720.00 | 24.00 | 596.00 | 24.00 |
| July | 363.67 | 24.00 | 744.00 | 24.00 | 363.67 | 24.00 |
| August | 727.67 | 24.00 | 744.00 | 24.00 | 727.67 | 24.00 |
| September | 640.50 | 24.00 | 720.00 | 24.00 | 640.50 | 24.00 |
| October | 681.50 | 24.00 | 744.00 | 24.00 | 681.50 | 24.00 |
| November | 454.00 | 24.00 | 720.00 | 24.00 | 454.00 | 24.00 |
| December | 323.50 | 24.00 | 744.00 | 24.00 | 323.50 | 24.00 |
| Annual Sum or Average | 5490.33 | 24.00 | 8760.00 | 24.00 | 5490.33 | 24.00 |
| Minimum of Months | 135.83 | 24.00 | 672.00 | 24.00 | 135.83 | 24.00 |
| Maximum of Months | 727.67 | 24.00 | 744.00 | 24.00 | 727.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 216.67 | 24.00 | 744.00 | 24.00 | 216.67 | 24.00 |
| February | 152.50 | 24.00 | 672.00 | 24.00 | 152.50 | 24.00 |
| March | 292.50 | 24.00 | 744.00 | 24.00 | 292.50 | 24.00 |
| April | 522.00 | 24.00 | 720.00 | 24.00 | 522.00 | 24.00 |
| May | 649.33 | 24.00 | 744.00 | 24.00 | 649.33 | 24.00 |
| June | 676.33 | 24.00 | 720.00 | 24.00 | 676.33 | 24.00 |
| July | 414.17 | 24.00 | 744.00 | 24.00 | 414.17 | 24.00 |
| August | 741.33 | 24.00 | 744.00 | 24.00 | 741.33 | 24.00 |
| September | 695.00 | 24.00 | 720.00 | 24.00 | 695.00 | 24.00 |
| October | 721.67 | 24.00 | 744.00 | 24.00 | 721.67 | 24.00 |
| November | 518.83 | 24.00 | 720.00 | 24.00 | 518.83 | 24.00 |
| December | 338.00 | 24.00 | 744.00 | 24.00 | 338.00 | 24.00 |
| Annual Sum or Average | 5938.33 | 24.00 | 8760.00 | 24.00 | 5938.33 | 24.00 |
| Minimum of Months | 152.50 | 24.00 | 672.00 | 24.00 | 152.50 | 24.00 |
| Maximum of Months | 741.33 | 24.00 | 744.00 | 24.00 | 741.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 217.17 | 24.00 | 744.00 | 24.00 | 217.17 | 24.00 |
| February | 152.67 | 24.00 | 672.00 | 24.00 | 152.67 | 24.00 |
| March | 292.50 | 24.00 | 744.00 | 24.00 | 292.50 | 24.00 |
| April | 521.50 | 24.00 | 720.00 | 24.00 | 521.50 | 24.00 |
| May | 649.00 | 24.00 | 744.00 | 24.00 | 649.00 | 24.00 |
| June | 675.83 | 24.00 | 720.00 | 24.00 | 675.83 | 24.00 |
| July | 413.50 | 24.00 | 744.00 | 24.00 | 413.50 | 24.00 |
| August | 741.33 | 24.00 | 744.00 | 24.00 | 741.33 | 24.00 |
| September | 694.33 | 24.00 | 720.00 | 24.00 | 694.33 | 24.00 |
| October | 721.17 | 24.00 | 744.00 | 24.00 | 721.17 | 24.00 |
| November | 518.17 | 24.00 | 720.00 | 24.00 | 518.17 | 24.00 |
| December | 338.00 | 24.00 | 744.00 | 24.00 | 338.00 | 24.00 |
| Annual Sum or Average | 5935.17 | 24.00 | 8760.00 | 24.00 | 5935.17 | 24.00 |
| Minimum of Months | 152.67 | 24.00 | 672.00 | 24.00 | 152.67 | 24.00 |
| Maximum of Months | 741.33 | 24.00 | 744.00 | 24.00 | 741.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 113.50 | 24.00 | 533.00 | 24.00 | 113.50 | 24.00 |
| February | 77.00 | 24.00 | 473.00 | 24.00 | 77.00 | 24.00 |
| March | 231.17 | 24.00 | 506.00 | 24.00 | 231.17 | 24.00 |
| April | 433.50 | 24.00 | 510.00 | 24.00 | 433.50 | 24.00 |
| May | 481.67 | 24.00 | 515.00 | 24.00 | 481.67 | 24.00 |
| June | 490.00 | 24.00 | 492.00 | 24.00 | 490.00 | 24.00 |
| July | 381.00 | 24.00 | 533.00 | 24.00 | 381.00 | 24.00 |
| August | 504.33 | 24.00 | 506.00 | 24.00 | 504.33 | 24.00 |
| September | 494.33 | 24.00 | 510.00 | 24.00 | 494.33 | 24.00 |
| October | 484.00 | 24.00 | 524.00 | 24.00 | 484.00 | 24.00 |
| November | 332.17 | 24.00 | 510.00 | 24.00 | 332.17 | 24.00 |
| December | 225.17 | 24.00 | 533.00 | 24.00 | 225.17 | 24.00 |
| Annual Sum or Average | 4247.83 | 24.00 | 6145.00 | 24.00 | 4247.83 | 24.00 |
| Minimum of Months | 77.00 | 24.00 | 473.00 | 24.00 | 77.00 | 24.00 |
| Maximum of Months | 504.33 | 24.00 | 533.00 | 24.00 | 504.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 113.83 | 24.00 | 533.00 | 24.00 | 113.83 | 24.00 |
| February | 77.00 | 24.00 | 473.00 | 24.00 | 77.00 | 24.00 |
| March | 232.00 | 24.00 | 506.00 | 24.00 | 232.00 | 24.00 |
| April | 433.67 | 24.00 | 510.00 | 24.00 | 433.67 | 24.00 |
| May | 481.33 | 24.00 | 515.00 | 24.00 | 481.33 | 24.00 |
| June | 490.00 | 24.00 | 492.00 | 24.00 | 490.00 | 24.00 |
| July | 380.67 | 24.00 | 533.00 | 24.00 | 380.67 | 24.00 |
| August | 504.33 | 24.00 | 506.00 | 24.00 | 504.33 | 24.00 |
| September | 494.67 | 24.00 | 510.00 | 24.00 | 494.67 | 24.00 |
| October | 483.83 | 24.00 | 524.00 | 24.00 | 483.83 | 24.00 |
| November | 332.83 | 24.00 | 510.00 | 24.00 | 332.83 | 24.00 |
| December | 225.17 | 24.00 | 533.00 | 24.00 | 225.17 | 24.00 |
| Annual Sum or Average | 4249.33 | 24.00 | 6145.00 | 24.00 | 4249.33 | 24.00 |
| Minimum of Months | 77.00 | 24.00 | 473.00 | 24.00 | 77.00 | 24.00 |
| Maximum of Months | 504.33 | 24.00 | 533.00 | 24.00 | 504.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 239.17 | 24.00 | 532.67 | 24.00 | 239.17 | 24.00 |
| February | 192.67 | 24.00 | 473.00 | 24.00 | 192.67 | 24.00 |
| March | 288.50 | 24.00 | 506.00 | 24.00 | 288.50 | 24.00 |
| April | 384.33 | 24.00 | 510.00 | 24.00 | 384.33 | 24.00 |
| May | 443.50 | 24.00 | 515.00 | 24.00 | 443.50 | 24.00 |
| June | 447.00 | 24.00 | 492.00 | 24.00 | 447.00 | 24.00 |
| July | 353.50 | 24.00 | 533.00 | 24.00 | 353.50 | 24.00 |
| August | 476.17 | 24.00 | 506.00 | 24.00 | 476.17 | 24.00 |
| September | 429.50 | 24.00 | 510.00 | 24.00 | 429.50 | 24.00 |
| October | 420.67 | 24.00 | 524.00 | 24.00 | 420.67 | 24.00 |
| November | 352.83 | 24.00 | 510.00 | 24.00 | 352.83 | 24.00 |
| December | 312.00 | 24.00 | 533.00 | 24.00 | 312.00 | 24.00 |
| Annual Sum or Average | 4339.83 | 24.00 | 6144.67 | 24.00 | 4339.83 | 24.00 |
| Minimum of Months | 192.67 | 24.00 | 473.00 | 24.00 | 192.67 | 24.00 |
| Maximum of Months | 476.17 | 24.00 | 533.00 | 24.00 | 476.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 293.83 | 24.00 | 743.00 | 24.00 | 293.83 | 24.00 |
| February | 232.83 | 24.00 | 672.00 | 24.00 | 232.83 | 24.00 |
| March | 336.83 | 24.00 | 744.00 | 24.00 | 336.83 | 24.00 |
| April | 440.00 | 24.00 | 720.00 | 24.00 | 440.00 | 24.00 |
| May | 579.67 | 24.00 | 744.00 | 24.00 | 579.67 | 24.00 |
| June | 536.00 | 24.00 | 720.00 | 24.00 | 536.00 | 24.00 |
| July | 398.00 | 24.00 | 744.00 | 24.00 | 398.00 | 24.00 |
| August | 656.00 | 24.00 | 744.00 | 24.00 | 656.00 | 24.00 |
| September | 579.17 | 24.00 | 720.00 | 24.00 | 579.17 | 24.00 |
| October | 582.83 | 24.00 | 744.00 | 24.00 | 582.83 | 24.00 |
| November | 448.17 | 24.00 | 720.00 | 24.00 | 448.17 | 24.00 |
| December | 374.83 | 24.00 | 744.00 | 24.00 | 374.83 | 24.00 |
| Annual Sum or Average | 5458.17 | 24.00 | 8759.00 | 24.00 | 5458.17 | 24.00 |
| Minimum of Months | 232.83 | 24.00 | 672.00 | 24.00 | 232.83 | 24.00 |
| Maximum of Months | 656.00 | 24.00 | 744.00 | 24.00 | 656.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 236.00 | 24.00 | 532.83 | 24.00 | 236.00 | 24.00 |
| February | 183.00 | 24.00 | 473.00 | 24.00 | 183.00 | 24.00 |
| March | 292.33 | 24.00 | 506.00 | 24.00 | 292.33 | 24.00 |
| April | 394.50 | 24.00 | 510.00 | 24.00 | 394.50 | 24.00 |
| May | 443.17 | 24.00 | 515.00 | 24.00 | 443.17 | 24.00 |
| June | 448.50 | 24.00 | 492.00 | 24.00 | 448.50 | 24.00 |
| July | 341.83 | 24.00 | 533.00 | 24.00 | 341.83 | 24.00 |
| August | 485.33 | 24.00 | 506.00 | 24.00 | 485.33 | 24.00 |
| September | 431.17 | 24.00 | 510.00 | 24.00 | 431.17 | 24.00 |
| October | 424.50 | 24.00 | 524.00 | 24.00 | 424.50 | 24.00 |
| November | 352.67 | 24.00 | 510.00 | 24.00 | 352.67 | 24.00 |
| December | 310.50 | 24.00 | 533.00 | 24.00 | 310.50 | 24.00 |
| Annual Sum or Average | 4343.50 | 24.00 | 6144.83 | 24.00 | 4343.50 | 24.00 |
| Minimum of Months | 183.00 | 24.00 | 473.00 | 24.00 | 183.00 | 24.00 |
| Maximum of Months | 485.33 | 24.00 | 533.00 | 24.00 | 485.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 280.33 | 24.00 | 743.50 | 24.00 | 280.33 | 24.00 |
| February | 213.67 | 24.00 | 672.00 | 24.00 | 213.67 | 24.00 |
| March | 326.33 | 24.00 | 744.00 | 24.00 | 326.33 | 24.00 |
| April | 431.33 | 24.00 | 720.00 | 24.00 | 431.33 | 24.00 |
| May | 571.00 | 24.00 | 744.00 | 24.00 | 571.00 | 24.00 |
| June | 517.50 | 24.00 | 720.00 | 24.00 | 517.50 | 24.00 |
| July | 370.33 | 24.00 | 744.00 | 24.00 | 370.33 | 24.00 |
| August | 654.67 | 24.00 | 744.00 | 24.00 | 654.67 | 24.00 |
| September | 559.67 | 24.00 | 720.00 | 24.00 | 559.67 | 24.00 |
| October | 579.33 | 24.00 | 744.00 | 24.00 | 579.33 | 24.00 |
| November | 436.83 | 24.00 | 720.00 | 24.00 | 436.83 | 24.00 |
| December | 365.00 | 24.00 | 744.00 | 24.00 | 365.00 | 24.00 |
| Annual Sum or Average | 5306.00 | 24.00 | 8759.50 | 24.00 | 5306.00 | 24.00 |
| Minimum of Months | 213.67 | 24.00 | 672.00 | 24.00 | 213.67 | 24.00 |
| Maximum of Months | 654.67 | 24.00 | 744.00 | 24.00 | 654.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 283.50 | 24.00 | 744.00 | 24.00 | 283.50 | 24.00 |
| February | 222.83 | 24.00 | 672.00 | 24.00 | 222.83 | 24.00 |
| March | 325.33 | 24.00 | 744.00 | 24.00 | 325.33 | 24.00 |
| April | 453.17 | 24.00 | 720.00 | 24.00 | 453.17 | 24.00 |
| May | 591.67 | 24.00 | 744.00 | 24.00 | 591.67 | 24.00 |
| June | 542.00 | 24.00 | 720.00 | 24.00 | 542.00 | 24.00 |
| July | 389.67 | 24.00 | 744.00 | 24.00 | 389.67 | 24.00 |
| August | 691.33 | 24.00 | 744.00 | 24.00 | 691.33 | 24.00 |
| September | 611.67 | 24.00 | 720.00 | 24.00 | 611.67 | 24.00 |
| October | 621.00 | 24.00 | 744.00 | 24.00 | 621.00 | 24.00 |
| November | 467.17 | 24.00 | 720.00 | 24.00 | 467.17 | 24.00 |
| December | 370.00 | 24.00 | 744.00 | 24.00 | 370.00 | 24.00 |
| Annual Sum or Average | 5569.33 | 24.00 | 8760.00 | 24.00 | 5569.33 | 24.00 |
| Minimum of Months | 222.83 | 24.00 | 672.00 | 24.00 | 222.83 | 24.00 |
| Maximum of Months | 691.33 | 24.00 | 744.00 | 24.00 | 691.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 283.50 | 24.00 | 744.00 | 24.00 | 283.50 | 24.00 |
| February | 222.17 | 24.00 | 672.00 | 24.00 | 222.17 | 24.00 |
| March | 324.33 | 24.00 | 744.00 | 24.00 | 324.33 | 24.00 |
| April | 453.17 | 24.00 | 720.00 | 24.00 | 453.17 | 24.00 |
| May | 591.33 | 24.00 | 744.00 | 24.00 | 591.33 | 24.00 |
| June | 541.50 | 24.00 | 720.00 | 24.00 | 541.50 | 24.00 |
| July | 388.33 | 24.00 | 744.00 | 24.00 | 388.33 | 24.00 |
| August | 691.33 | 24.00 | 744.00 | 24.00 | 691.33 | 24.00 |
| September | 611.33 | 24.00 | 720.00 | 24.00 | 611.33 | 24.00 |
| October | 621.33 | 24.00 | 744.00 | 24.00 | 621.33 | 24.00 |
| November | 466.83 | 24.00 | 720.00 | 24.00 | 466.83 | 24.00 |
| December | 370.00 | 24.00 | 744.00 | 24.00 | 370.00 | 24.00 |
| Annual Sum or Average | 5565.17 | 24.00 | 8760.00 | 24.00 | 5565.17 | 24.00 |
| Minimum of Months | 222.17 | 24.00 | 672.00 | 24.00 | 222.17 | 24.00 |
| Maximum of Months | 691.33 | 24.00 | 744.00 | 24.00 | 691.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 217.33 | 24.00 | 533.00 | 24.00 | 217.33 | 24.00 |
| February | 168.83 | 24.00 | 473.00 | 24.00 | 168.83 | 24.00 |
| March | 272.33 | 24.00 | 506.00 | 24.00 | 272.33 | 24.00 |
| April | 397.17 | 24.00 | 510.00 | 24.00 | 397.17 | 24.00 |
| May | 452.00 | 24.00 | 515.00 | 24.00 | 452.00 | 24.00 |
| June | 462.17 | 24.00 | 492.00 | 24.00 | 462.17 | 24.00 |
| July | 351.33 | 24.00 | 533.00 | 24.00 | 351.33 | 24.00 |
| August | 492.00 | 24.00 | 506.00 | 24.00 | 492.00 | 24.00 |
| September | 452.17 | 24.00 | 510.00 | 24.00 | 452.17 | 24.00 |
| October | 429.83 | 24.00 | 524.00 | 24.00 | 429.83 | 24.00 |
| November | 351.67 | 24.00 | 510.00 | 24.00 | 351.67 | 24.00 |
| December | 287.67 | 24.00 | 533.00 | 24.00 | 287.67 | 24.00 |
| Annual Sum or Average | 4334.50 | 24.00 | 6145.00 | 24.00 | 4334.50 | 24.00 |
| Minimum of Months | 168.83 | 24.00 | 473.00 | 24.00 | 168.83 | 24.00 |
| Maximum of Months | 492.00 | 24.00 | 533.00 | 24.00 | 492.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 217.50 | 24.00 | 533.00 | 24.00 | 217.50 | 24.00 |
| February | 169.33 | 24.00 | 473.00 | 24.00 | 169.33 | 24.00 |
| March | 273.17 | 24.00 | 506.00 | 24.00 | 273.17 | 24.00 |
| April | 397.33 | 24.00 | 510.00 | 24.00 | 397.33 | 24.00 |
| May | 451.50 | 24.00 | 515.00 | 24.00 | 451.50 | 24.00 |
| June | 462.33 | 24.00 | 492.00 | 24.00 | 462.33 | 24.00 |
| July | 351.17 | 24.00 | 533.00 | 24.00 | 351.17 | 24.00 |
| August | 492.33 | 24.00 | 506.00 | 24.00 | 492.33 | 24.00 |
| September | 452.17 | 24.00 | 510.00 | 24.00 | 452.17 | 24.00 |
| October | 430.50 | 24.00 | 524.00 | 24.00 | 430.50 | 24.00 |
| November | 351.67 | 24.00 | 510.00 | 24.00 | 351.67 | 24.00 |
| December | 287.83 | 24.00 | 533.00 | 24.00 | 287.83 | 24.00 |
| Annual Sum or Average | 4336.83 | 24.00 | 6145.00 | 24.00 | 4336.83 | 24.00 |
| Minimum of Months | 169.33 | 24.00 | 473.00 | 24.00 | 169.33 | 24.00 |
| Maximum of Months | 492.33 | 24.00 | 533.00 | 24.00 | 492.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 26.30 | 744.00 | 26.30 | 744.00 | 26.30 |
| February | 672.00 | 26.40 | 672.00 | 26.40 | 672.00 | 26.40 |
| March | 744.00 | 26.51 | 744.00 | 26.51 | 744.00 | 26.51 |
| April | 720.00 | 26.61 | 720.00 | 26.61 | 720.00 | 26.61 |
| May | 744.00 | 26.62 | 744.00 | 26.62 | 744.00 | 26.62 |
| June | 720.00 | 26.67 | 720.00 | 26.67 | 720.00 | 26.67 |
| July | 744.00 | 26.43 | 744.00 | 26.43 | 744.00 | 26.43 |
| August | 744.00 | 26.39 | 744.00 | 26.39 | 744.00 | 26.39 |
| September | 720.00 | 26.43 | 720.00 | 26.43 | 720.00 | 26.43 |
| October | 744.00 | 26.32 | 744.00 | 26.32 | 744.00 | 26.32 |
| November | 720.00 | 26.31 | 720.00 | 26.31 | 720.00 | 26.31 |
| December | 744.00 | 26.23 | 744.00 | 26.23 | 744.00 | 26.23 |
| Annual Sum or Average | 8760.00 | 26.44 | 8760.00 | 26.44 | 8760.00 | 26.44 |
| Minimum of Months | 672.00 | 26.23 | 672.00 | 26.23 | 672.00 | 26.23 |
| Maximum of Months | 744.00 | 26.67 | 744.00 | 26.67 | 744.00 | 26.67 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 740.33 | 27.05 | 744.00 | 27.05 | 740.33 | 27.05 |
| February | 670.17 | 27.28 | 672.00 | 27.28 | 670.17 | 27.28 |
| March | 744.00 | 27.44 | 744.00 | 27.44 | 744.00 | 27.44 |
| April | 720.00 | 27.59 | 720.00 | 27.59 | 720.00 | 27.59 |
| May | 744.00 | 27.61 | 744.00 | 27.61 | 744.00 | 27.61 |
| June | 720.00 | 27.65 | 720.00 | 27.65 | 720.00 | 27.65 |
| July | 744.00 | 27.21 | 744.00 | 27.21 | 744.00 | 27.21 |
| August | 744.00 | 27.22 | 744.00 | 27.22 | 744.00 | 27.22 |
| September | 720.00 | 27.24 | 720.00 | 27.24 | 720.00 | 27.24 |
| October | 744.00 | 27.05 | 744.00 | 27.05 | 744.00 | 27.05 |
| November | 720.00 | 27.05 | 720.00 | 27.05 | 720.00 | 27.05 |
| December | 743.00 | 26.95 | 744.00 | 26.95 | 743.00 | 26.95 |
| Annual Sum or Average | 8753.50 | 27.28 | 8760.00 | 27.28 | 8753.50 | 27.28 |
| Minimum of Months | 670.17 | 26.95 | 672.00 | 26.95 | 670.17 | 26.95 |
| Maximum of Months | 744.00 | 27.65 | 744.00 | 27.65 | 744.00 | 27.65 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 26.14 | 744.00 | 26.14 | 744.00 | 26.14 |
| February | 672.00 | 26.21 | 672.00 | 26.21 | 672.00 | 26.21 |
| March | 744.00 | 26.23 | 744.00 | 26.23 | 744.00 | 26.23 |
| April | 720.00 | 26.25 | 720.00 | 26.25 | 720.00 | 26.25 |
| May | 744.00 | 26.25 | 744.00 | 26.25 | 744.00 | 26.25 |
| June | 720.00 | 26.29 | 720.00 | 26.29 | 720.00 | 26.29 |
| July | 744.00 | 26.16 | 744.00 | 26.16 | 744.00 | 26.16 |
| August | 744.00 | 26.14 | 744.00 | 26.14 | 744.00 | 26.14 |
| September | 720.00 | 26.14 | 720.00 | 26.14 | 720.00 | 26.14 |
| October | 744.00 | 26.10 | 744.00 | 26.10 | 744.00 | 26.10 |
| November | 720.00 | 26.12 | 720.00 | 26.12 | 720.00 | 26.12 |
| December | 744.00 | 26.10 | 744.00 | 26.10 | 744.00 | 26.10 |
| Annual Sum or Average | 8760.00 | 26.18 | 8760.00 | 26.18 | 8760.00 | 26.18 |
| Minimum of Months | 672.00 | 26.10 | 672.00 | 26.10 | 672.00 | 26.10 |
| Maximum of Months | 744.00 | 26.29 | 744.00 | 26.29 | 744.00 | 26.29 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.574906E+10 | 0.145447E+10 | 744.00 | 0.434863E+10 | 0.140044E+10 | 0.00 | 0.58 | 05-JAN-15:00 | 0.11 | 23-JAN-06:05 | 3414.27 | 05-JAN-15:00 | 2932.36 | 05-JAN-15:00 | 867.11 | 11-JAN-19:40 | 944.87 | 05-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.550104E+10 | 0.140642E+10 | 672.00 | 0.415865E+10 | 0.134239E+10 | 0.00 | 0.61 | 28-FEB-15:10 | 0.20 | 24-FEB-07:00 | 3673.29 | 28-FEB-15:10 | 2955.42 | 28-FEB-15:10 | 937.98 | 14-FEB-19:40 | 1017.74 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.633116E+10 | 0.162656E+10 | 744.00 | 0.460634E+10 | 0.172482E+10 | 0.00 | 0.65 | 19-MAR-16:10 | 0.19 | 04-MAR-05:00 | 4009.66 | 19-MAR-16:10 | 3132.35 | 19-MAR-15:40 | 974.83 | 28-MAR-19:40 | 1090.35 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.655857E+10 | 0.168607E+10 | 720.00 | 0.447647E+10 | 0.208210E+10 | 0.00 | 0.64 | 02-APR-16:10 | 0.24 | 23-APR-04:00 | 4004.16 | 02-APR-16:10 | 2854.19 | 02-APR-16:02 | 1243.02 | 29-APR-16:15 | 1064.50 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.722474E+10 | 0.183639E+10 | 744.00 | 0.462456E+10 | 0.260018E+10 | 0.00 | 0.68 | 06-MAY-15:10 | 0.23 | 26-MAY-04:00 | 4206.90 | 06-MAY-16:02 | 3082.44 | 06-MAY-15:10 | 1475.94 | 23-MAY-14:10 | 1175.39 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.707379E+10 | 0.179427E+10 | 720.00 | 0.454340E+10 | 0.253040E+10 | 0.00 | 0.66 | 13-JUN-16:01 | 0.25 | 27-JUN-05:00 | 4124.34 | 13-JUN-16:01 | 2876.54 | 13-JUN-16:10 | 1483.93 | 15-JUN-10:30 | 1128.47 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.602076E+10 | 0.151314E+10 | 744.00 | 0.417647E+10 | 0.184428E+10 | 0.00 | 0.56 | 04-JUL-16:10 | 0.22 | 13-JUL-05:00 | 3517.37 | 04-JUL-16:10 | 2555.21 | 04-JUL-16:10 | 987.39 | 29-JUL-12:20 | 914.92 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.665594E+10 | 0.165495E+10 | 744.00 | 0.420971E+10 | 0.244623E+10 | 0.00 | 0.62 | 12-AUG-16:40 | 0.22 | 20-AUG-04:00 | 3956.51 | 12-AUG-16:03 | 2677.58 | 27-AUG-16:05 | 1412.75 | 12-AUG-15:20 | 1034.81 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.629234E+10 | 0.157382E+10 | 720.00 | 0.414313E+10 | 0.214921E+10 | 0.00 | 0.61 | 04-SEP-16:03 | 0.23 | 16-SEP-03:00 | 3811.89 | 04-SEP-16:03 | 2646.70 | 04-SEP-16:05 | 1304.25 | 25-SEP-14:00 | 1008.40 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.616021E+10 | 0.152736E+10 | 744.00 | 0.407979E+10 | 0.208043E+10 | 0.00 | 0.60 | 29-OCT-13:00 | 0.21 | 23-OCT-05:00 | 3778.73 | 29-OCT-13:30 | 2615.06 | 28-OCT-15:10 | 1260.64 | 29-OCT-15:30 | 983.48 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.586750E+10 | 0.146359E+10 | 720.00 | 0.410801E+10 | 0.175949E+10 | 0.00 | 0.58 | 04-NOV-15:20 | 0.17 | 25-NOV-05:00 | 3629.87 | 04-NOV-15:20 | 2719.08 | 19-NOV-14:20 | 1192.80 | 10-NOV-13:30 | 955.73 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.574316E+10 | 0.143887E+10 | 744.00 | 0.422879E+10 | 0.151437E+10 | 0.00 | 0.55 | 30-DEC-14:20 | 0.09 | 21-DEC-06:05 | 3416.46 | 30-DEC-16:10 | 2799.22 | 08-DEC-14:30 | 983.04 | 10-DEC-18:30 | 897.11 | 30-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.751783E+11 | 0.189759E+11 | 8760.00 | 0.517039E+11 | 0.234743E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.550104E+10 | 0.140642E+10 | 672.00 | 0.407979E+10 | 0.134239E+10 | 0.00 | 0.55 | 0.09 | 3414.27 | 2555.21 | 867.11 | 897.11 | 0.00 | |||||||
| Maximum of Months | 0.722474E+10 | 0.183639E+10 | 744.00 | 0.462456E+10 | 0.260018E+10 | 0.00 | 0.68 | 0.25 | 4206.90 | 3132.35 | 1483.93 | 1175.39 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.497449E+10 | 0.126302E+10 | 744.00 | 0.365756E+10 | 0.131693E+10 | 0.00 | 0.48 | 05-JAN-15:00 | 0.09 | 23-JAN-06:05 | 2856.94 | 04-JAN-16:10 | 2329.57 | 31-JAN-16:10 | 842.35 | 11-JAN-19:30 | 784.23 | 05-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.492817E+10 | 0.126379E+10 | 672.00 | 0.364460E+10 | 0.128357E+10 | 0.00 | 0.54 | 28-FEB-15:10 | 0.17 | 24-FEB-07:00 | 3270.57 | 28-FEB-15:10 | 2566.39 | 28-FEB-15:10 | 915.26 | 14-FEB-19:40 | 912.21 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.606237E+10 | 0.155908E+10 | 744.00 | 0.436671E+10 | 0.169566E+10 | 0.00 | 0.61 | 19-MAR-16:10 | 0.18 | 04-MAR-05:00 | 3714.11 | 19-MAR-16:10 | 2871.08 | 19-MAR-16:10 | 965.34 | 28-MAR-19:40 | 1016.76 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.661254E+10 | 0.169929E+10 | 720.00 | 0.452568E+10 | 0.208686E+10 | 0.00 | 0.62 | 02-APR-16:10 | 0.24 | 23-APR-04:00 | 3909.45 | 29-APR-16:15 | 2809.31 | 11-APR-16:10 | 1221.41 | 29-APR-16:15 | 1032.32 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.749630E+10 | 0.190317E+10 | 744.00 | 0.485998E+10 | 0.263632E+10 | 0.00 | 0.71 | 06-MAY-15:10 | 0.24 | 26-MAY-04:00 | 4379.28 | 06-MAY-15:10 | 3248.87 | 06-MAY-15:10 | 1521.91 | 23-MAY-14:10 | 1223.22 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.754347E+10 | 0.190936E+10 | 720.00 | 0.495110E+10 | 0.259237E+10 | 0.00 | 0.72 | 13-JUN-16:01 | 0.26 | 27-JUN-05:00 | 4535.91 | 16-JUN-15:30 | 3231.88 | 13-JUN-16:10 | 1544.93 | 15-JUN-10:30 | 1225.80 | 13-JUN-16:01 | 0.00 | 01-JUN-00:10 |
| July | 0.629752E+10 | 0.158072E+10 | 744.00 | 0.442228E+10 | 0.187524E+10 | 0.00 | 0.59 | 04-JUL-16:10 | 0.23 | 13-JUL-05:00 | 3717.48 | 04-JUL-16:10 | 2812.58 | 14-JUL-17:07 | 1028.94 | 05-JUL-11:10 | 964.06 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.682422E+10 | 0.169555E+10 | 744.00 | 0.435192E+10 | 0.247230E+10 | 0.00 | 0.63 | 09-AUG-16:10 | 0.22 | 20-AUG-04:00 | 4011.29 | 12-AUG-15:20 | 2749.52 | 01-AUG-16:03 | 1422.91 | 12-AUG-15:10 | 1057.26 | 13-AUG-15:00 | 0.00 | 01-AUG-00:10 |
| September | 0.623667E+10 | 0.155999E+10 | 720.00 | 0.409672E+10 | 0.213995E+10 | 0.00 | 0.59 | 04-SEP-16:03 | 0.23 | 16-SEP-03:00 | 3730.70 | 04-SEP-16:03 | 2615.29 | 02-SEP-17:00 | 1299.64 | 25-SEP-14:00 | 989.02 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.587446E+10 | 0.145742E+10 | 744.00 | 0.383536E+10 | 0.203910E+10 | 0.00 | 0.56 | 04-OCT-16:03 | 0.21 | 23-OCT-05:00 | 3489.52 | 04-OCT-16:03 | 2491.60 | 04-OCT-16:03 | 1192.40 | 29-OCT-15:20 | 913.96 | 04-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.532004E+10 | 0.132942E+10 | 720.00 | 0.362927E+10 | 0.169077E+10 | 0.00 | 0.51 | 04-NOV-15:10 | 0.15 | 25-NOV-06:05 | 3179.96 | 10-NOV-13:30 | 2263.89 | 03-NOV-16:03 | 1165.96 | 10-NOV-13:30 | 825.05 | 10-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.495903E+10 | 0.124602E+10 | 744.00 | 0.353504E+10 | 0.142399E+10 | 0.00 | 0.47 | 30-DEC-16:10 | 0.07 | 21-DEC-06:05 | 2906.63 | 30-DEC-16:10 | 2143.01 | 07-DEC-15:20 | 932.99 | 10-DEC-18:40 | 760.04 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.731293E+11 | 0.184668E+11 | 8760.00 | 0.498762E+11 | 0.232531E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.492817E+10 | 0.124602E+10 | 672.00 | 0.353504E+10 | 0.128357E+10 | 0.00 | 0.47 | 0.07 | 2856.94 | 2143.01 | 842.35 | 760.04 | 0.00 | |||||||
| Maximum of Months | 0.754347E+10 | 0.190936E+10 | 744.00 | 0.495110E+10 | 0.263632E+10 | 0.00 | 0.72 | 0.26 | 4535.91 | 3248.87 | 1544.93 | 1225.80 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.385692E+10 | 0.955859E+09 | 380.36 | 0.304760E+10 | 0.809320E+09 | 0.00 | 1.00 | 03-JAN-07:03 | 0.00 | 01-JAN-03:10 | 8534.86 | 09-JAN-07:03 | 6529.39 | 23-JAN-08:62 | 3970.19 | 10-JAN-08:03 | 1818.19 | 11-JAN-08:03 | 0.00 | 01-JAN-00:10 |
| February | 0.379584E+10 | 0.949984E+09 | 366.87 | 0.299038E+10 | 0.805462E+09 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:10 | 8534.86 | 06-FEB-07:03 | 6281.40 | 24-FEB-08:62 | 4105.60 | 16-FEB-08:03 | 1781.46 | 28-FEB-09:15 | 0.00 | 01-FEB-00:10 |
| March | 0.448673E+10 | 0.113199E+10 | 395.31 | 0.342601E+10 | 0.106071E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:10 | 8534.00 | 15-MAR-07:02 | 5977.71 | 03-MAR-09:02 | 4325.60 | 28-MAR-07:05 | 1829.45 | 09-MAR-09:02 | 0.00 | 01-MAR-00:10 |
| April | 0.436150E+10 | 0.109161E+10 | 425.36 | 0.309743E+10 | 0.126407E+10 | 0.00 | 1.00 | 03-APR-06:03 | 0.00 | 01-APR-00:10 | 8531.38 | 24-APR-06:03 | 5257.03 | 03-APR-08:62 | 4584.18 | 19-APR-06:03 | 1827.82 | 11-APR-08:15 | 0.00 | 01-APR-00:10 |
| May | 0.516977E+10 | 0.127561E+10 | 463.39 | 0.340278E+10 | 0.176699E+10 | 0.00 | 1.00 | 01-MAY-06:03 | 0.00 | 01-MAY-16:01 | 8534.00 | 17-MAY-07:02 | 5249.37 | 01-MAY-08:40 | 5451.08 | 19-MAY-06:03 | 1893.44 | 05-MAY-08:63 | 0.00 | 01-MAY-00:10 |
| June | 0.506951E+10 | 0.125496E+10 | 419.01 | 0.336003E+10 | 0.170948E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 8533.78 | 26-JUN-06:03 | 5211.70 | 19-JUN-10:00 | 5176.93 | 29-JUN-06:03 | 1864.51 | 14-JUN-08:63 | 0.00 | 01-JUN-00:10 |
| July | 0.394771E+10 | 0.957540E+09 | 422.88 | 0.281303E+10 | 0.113468E+10 | 0.00 | 1.00 | 03-JUL-06:03 | 0.00 | 01-JUL-00:10 | 8534.00 | 12-JUL-07:02 | 5404.29 | 17-JUL-08:62 | 4207.66 | 11-JUL-07:03 | 1778.60 | 03-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.477639E+10 | 0.115344E+10 | 359.78 | 0.312532E+10 | 0.165106E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 8530.09 | 29-AUG-06:03 | 5248.38 | 28-AUG-08:63 | 5152.84 | 11-AUG-06:03 | 1834.84 | 28-AUG-08:63 | 0.00 | 01-AUG-00:10 |
| September | 0.425551E+10 | 0.103043E+10 | 389.77 | 0.286003E+10 | 0.139548E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 8535.05 | 18-SEP-07:02 | 5191.01 | 05-SEP-08:63 | 4703.71 | 07-SEP-06:03 | 1814.29 | 01-SEP-08:15 | 0.00 | 01-SEP-00:10 |
| October | 0.421105E+10 | 0.101035E+10 | 382.40 | 0.286275E+10 | 0.134831E+10 | 0.00 | 1.00 | 02-OCT-06:03 | 0.00 | 01-OCT-03:00 | 8535.05 | 23-OCT-07:02 | 5301.06 | 02-OCT-08:62 | 4767.24 | 26-OCT-07:05 | 1813.01 | 05-OCT-08:15 | 0.00 | 01-OCT-00:10 |
| November | 0.399038E+10 | 0.968686E+09 | 363.24 | 0.288490E+10 | 0.110547E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 8535.00 | 06-NOV-07:03 | 5848.08 | 24-NOV-09:02 | 4443.17 | 03-NOV-07:05 | 1795.60 | 14-NOV-09:15 | 0.00 | 01-NOV-00:10 |
| December | 0.372214E+10 | 0.916409E+09 | 357.56 | 0.288733E+10 | 0.834814E+09 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 8535.05 | 26-DEC-07:03 | 6142.29 | 21-DEC-08:62 | 4080.88 | 12-DEC-08:05 | 1801.31 | 08-DEC-09:02 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.516434E+11 | 0.126969E+11 | 4725.93 | 0.367576E+11 | 0.148859E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.372214E+10 | 0.916409E+09 | 357.56 | 0.281303E+10 | 0.805462E+09 | 0.00 | 1.00 | 0.00 | 8530.09 | 5191.01 | 3970.19 | 1778.60 | 0.00 | |||||||
| Maximum of Months | 0.516977E+10 | 0.127561E+10 | 463.39 | 0.342601E+10 | 0.176699E+10 | 0.00 | 1.00 | 0.00 | 8535.05 | 6529.39 | 5451.08 | 1893.44 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.498134E+10 | 0.126243E+10 | 744.00 | 0.365057E+10 | 0.133077E+10 | 0.00 | 0.49 | 04-JAN-13:00 | 0.09 | 23-JAN-06:05 | 2787.79 | 04-JAN-13:00 | 2236.66 | 04-JAN-13:00 | 842.55 | 11-JAN-19:30 | 779.24 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.494424E+10 | 0.126517E+10 | 672.00 | 0.364764E+10 | 0.129661E+10 | 0.00 | 0.53 | 28-FEB-15:00 | 0.19 | 03-FEB-06:05 | 3066.55 | 28-FEB-15:10 | 2398.82 | 28-FEB-15:00 | 918.39 | 14-FEB-19:40 | 861.88 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.605191E+10 | 0.155403E+10 | 744.00 | 0.434582E+10 | 0.170609E+10 | 0.00 | 0.59 | 19-MAR-16:10 | 0.18 | 04-MAR-05:00 | 3444.85 | 19-MAR-16:10 | 2622.70 | 19-MAR-16:10 | 958.64 | 28-MAR-19:40 | 945.65 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.662551E+10 | 0.169934E+10 | 720.00 | 0.452643E+10 | 0.209908E+10 | 0.00 | 0.59 | 30-APR-16:20 | 0.25 | 23-APR-04:00 | 3618.37 | 30-APR-16:20 | 2530.85 | 11-APR-16:10 | 1196.65 | 10-APR-18:00 | 945.96 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.752371E+10 | 0.190584E+10 | 744.00 | 0.487355E+10 | 0.265016E+10 | 0.00 | 0.70 | 06-MAY-15:10 | 0.25 | 26-MAY-04:00 | 4135.69 | 06-MAY-15:10 | 3040.23 | 06-MAY-15:10 | 1512.19 | 22-MAY-10:00 | 1157.45 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.757272E+10 | 0.191221E+10 | 720.00 | 0.496601E+10 | 0.260671E+10 | 0.00 | 0.71 | 13-JUN-15:10 | 0.27 | 27-JUN-05:00 | 4317.05 | 15-JUN-10:30 | 2994.04 | 13-JUN-15:10 | 1577.97 | 15-JUN-10:20 | 1167.74 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.631746E+10 | 0.158258E+10 | 744.00 | 0.442859E+10 | 0.188887E+10 | 0.00 | 0.57 | 28-JUL-13:00 | 0.24 | 13-JUL-05:00 | 3390.82 | 28-JUL-13:00 | 2502.48 | 15-JUL-16:02 | 1053.23 | 05-JUL-10:50 | 908.28 | 28-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.685693E+10 | 0.170038E+10 | 744.00 | 0.436934E+10 | 0.248759E+10 | 0.00 | 0.62 | 01-AUG-15:10 | 0.23 | 20-AUG-04:00 | 3810.12 | 01-AUG-15:10 | 2557.49 | 01-AUG-15:10 | 1408.96 | 07-AUG-12:10 | 1004.94 | 13-AUG-15:00 | 0.00 | 01-AUG-00:10 |
| September | 0.627053E+10 | 0.156553E+10 | 720.00 | 0.411668E+10 | 0.215385E+10 | 0.00 | 0.58 | 02-SEP-14:10 | 0.24 | 16-SEP-03:00 | 3514.59 | 02-SEP-14:10 | 2401.84 | 02-SEP-14:10 | 1297.08 | 25-SEP-12:00 | 935.12 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.588610E+10 | 0.145801E+10 | 744.00 | 0.383597E+10 | 0.205013E+10 | 0.00 | 0.55 | 29-OCT-13:00 | 0.22 | 23-OCT-05:00 | 3310.11 | 29-OCT-13:00 | 2229.50 | 04-OCT-15:10 | 1146.75 | 29-OCT-15:20 | 867.59 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.533714E+10 | 0.133135E+10 | 720.00 | 0.363390E+10 | 0.170324E+10 | 0.00 | 0.52 | 10-NOV-13:30 | 0.16 | 25-NOV-05:00 | 3193.33 | 10-NOV-13:30 | 2126.05 | 18-NOV-13:00 | 1156.54 | 10-NOV-13:30 | 825.78 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.496883E+10 | 0.124635E+10 | 744.00 | 0.353167E+10 | 0.143715E+10 | 0.00 | 0.48 | 09-DEC-14:00 | 0.08 | 21-DEC-06:05 | 2860.36 | 09-DEC-14:00 | 2033.24 | 09-DEC-14:00 | 934.01 | 10-DEC-18:40 | 750.44 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.733364E+11 | 0.184832E+11 | 8760.00 | 0.499262E+11 | 0.234102E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.494424E+10 | 0.124635E+10 | 672.00 | 0.353167E+10 | 0.129661E+10 | 0.00 | 0.48 | 0.08 | 2787.79 | 2033.24 | 842.55 | 750.44 | 0.00 | |||||||
| Maximum of Months | 0.757272E+10 | 0.191221E+10 | 744.00 | 0.496601E+10 | 0.265016E+10 | 0.00 | 0.71 | 0.27 | 4317.05 | 3040.23 | 1577.97 | 1167.74 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.430857E+10 | 0.109131E+10 | 744.00 | 0.311165E+10 | 0.119692E+10 | 0.00 | 0.44 | 04-JAN-13:00 | 0.10 | 23-JAN-06:05 | 2325.44 | 11-JAN-17:10 | 1758.25 | 04-JAN-13:00 | 720.98 | 11-JAN-19:40 | 628.45 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.421362E+10 | 0.107832E+10 | 672.00 | 0.305670E+10 | 0.115692E+10 | 0.00 | 0.47 | 28-FEB-15:00 | 0.18 | 24-FEB-07:00 | 2461.98 | 13-FEB-16:10 | 1889.36 | 28-FEB-15:00 | 787.30 | 14-FEB-19:50 | 693.03 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.508436E+10 | 0.130737E+10 | 744.00 | 0.359910E+10 | 0.148526E+10 | 0.00 | 0.53 | 19-MAR-16:10 | 0.19 | 04-MAR-04:00 | 2747.62 | 19-MAR-16:10 | 2092.40 | 19-MAR-16:10 | 819.80 | 28-MAR-19:50 | 761.92 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.559424E+10 | 0.143668E+10 | 720.00 | 0.374546E+10 | 0.184878E+10 | 0.00 | 0.55 | 30-APR-16:20 | 0.26 | 23-APR-04:00 | 2984.02 | 29-APR-16:15 | 2053.12 | 11-APR-16:10 | 1036.06 | 10-APR-18:00 | 784.18 | 30-APR-16:20 | 0.00 | 01-APR-00:10 |
| May | 0.644842E+10 | 0.163506E+10 | 744.00 | 0.410697E+10 | 0.234145E+10 | 0.00 | 0.63 | 06-MAY-15:10 | 0.26 | 26-MAY-04:00 | 3324.74 | 06-MAY-15:10 | 2420.65 | 06-MAY-15:10 | 1225.89 | 23-MAY-14:10 | 940.50 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.647706E+10 | 0.163785E+10 | 720.00 | 0.417484E+10 | 0.230222E+10 | 0.00 | 0.66 | 13-JUN-16:01 | 0.28 | 27-JUN-05:00 | 3568.40 | 13-JUN-16:01 | 2470.72 | 13-JUN-16:10 | 1316.23 | 15-JUN-10:30 | 975.10 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.546983E+10 | 0.137008E+10 | 744.00 | 0.377187E+10 | 0.169795E+10 | 0.00 | 0.53 | 26-JUL-17:00 | 0.25 | 13-JUL-05:00 | 2848.13 | 04-JUL-16:10 | 2129.59 | 14-JUL-17:07 | 862.44 | 24-JUL-17:20 | 763.18 | 26-JUL-17:00 | 0.00 | 01-JUL-00:10 |
| August | 0.586998E+10 | 0.145677E+10 | 744.00 | 0.367989E+10 | 0.219009E+10 | 0.00 | 0.57 | 13-AUG-15:10 | 0.24 | 20-AUG-04:00 | 3137.25 | 12-AUG-17:00 | 2089.46 | 01-AUG-16:03 | 1169.93 | 12-AUG-12:00 | 834.86 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.539067E+10 | 0.134514E+10 | 720.00 | 0.345879E+10 | 0.193188E+10 | 0.00 | 0.53 | 04-SEP-16:03 | 0.24 | 16-SEP-03:00 | 2886.39 | 04-SEP-16:03 | 1932.27 | 04-SEP-16:05 | 1072.71 | 25-SEP-11:50 | 770.30 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.514299E+10 | 0.127245E+10 | 744.00 | 0.329188E+10 | 0.185111E+10 | 0.00 | 0.49 | 29-OCT-13:00 | 0.23 | 23-OCT-04:00 | 2635.09 | 29-OCT-13:00 | 1800.19 | 04-OCT-16:03 | 938.99 | 16-OCT-13:00 | 696.55 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.466481E+10 | 0.116212E+10 | 720.00 | 0.311860E+10 | 0.154621E+10 | 0.00 | 0.47 | 10-NOV-13:40 | 0.17 | 25-NOV-06:05 | 2584.09 | 10-NOV-13:30 | 1720.77 | 18-NOV-13:00 | 958.76 | 10-NOV-13:40 | 673.57 | 10-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.433724E+10 | 0.108640E+10 | 744.00 | 0.303151E+10 | 0.130573E+10 | 0.00 | 0.44 | 09-DEC-14:00 | 0.08 | 21-DEC-06:05 | 2364.15 | 10-DEC-18:30 | 1650.75 | 09-DEC-14:00 | 832.89 | 10-DEC-18:50 | 620.77 | 29-DEC-19:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.630018E+11 | 0.158796E+11 | 8760.00 | 0.421473E+11 | 0.208545E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.421362E+10 | 0.107832E+10 | 672.00 | 0.303151E+10 | 0.115692E+10 | 0.00 | 0.44 | 0.08 | 2325.44 | 1650.75 | 720.98 | 620.77 | 0.00 | |||||||
| Maximum of Months | 0.647706E+10 | 0.163785E+10 | 744.00 | 0.417484E+10 | 0.234145E+10 | 0.00 | 0.66 | 0.28 | 3568.40 | 2470.72 | 1316.23 | 975.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.430898E+10 | 0.109138E+10 | 744.00 | 0.311181E+10 | 0.119716E+10 | 0.00 | 0.44 | 04-JAN-13:00 | 0.10 | 23-JAN-06:05 | 2323.50 | 11-JAN-17:10 | 1761.81 | 04-JAN-13:00 | 720.88 | 11-JAN-19:40 | 629.41 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.421423E+10 | 0.107843E+10 | 672.00 | 0.305708E+10 | 0.115716E+10 | 0.00 | 0.48 | 28-FEB-15:00 | 0.18 | 24-FEB-07:00 | 2459.55 | 13-FEB-16:10 | 1888.92 | 28-FEB-15:00 | 787.37 | 14-FEB-19:50 | 692.78 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.508397E+10 | 0.130725E+10 | 744.00 | 0.359863E+10 | 0.148534E+10 | 0.00 | 0.52 | 19-MAR-16:10 | 0.19 | 04-MAR-04:00 | 2743.21 | 19-MAR-16:10 | 2088.59 | 19-MAR-16:10 | 819.41 | 28-MAR-19:50 | 760.73 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.559467E+10 | 0.143673E+10 | 720.00 | 0.374569E+10 | 0.184898E+10 | 0.00 | 0.55 | 30-APR-16:20 | 0.26 | 23-APR-04:00 | 2979.34 | 29-APR-16:15 | 2050.87 | 11-APR-16:10 | 1036.29 | 10-APR-18:00 | 783.16 | 30-APR-16:20 | 0.00 | 01-APR-00:10 |
| May | 0.644934E+10 | 0.163521E+10 | 744.00 | 0.410762E+10 | 0.234173E+10 | 0.00 | 0.63 | 06-MAY-15:10 | 0.26 | 26-MAY-04:00 | 3323.17 | 06-MAY-15:10 | 2419.57 | 06-MAY-15:10 | 1225.54 | 23-MAY-14:10 | 940.02 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.647807E+10 | 0.163802E+10 | 720.00 | 0.417555E+10 | 0.230252E+10 | 0.00 | 0.66 | 13-JUN-16:10 | 0.28 | 27-JUN-05:00 | 3564.15 | 13-JUN-16:01 | 2467.21 | 13-JUN-16:10 | 1317.16 | 15-JUN-10:30 | 974.43 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.547060E+10 | 0.137021E+10 | 744.00 | 0.377236E+10 | 0.169824E+10 | 0.00 | 0.53 | 26-JUL-17:00 | 0.25 | 13-JUL-05:00 | 2842.75 | 04-JUL-16:10 | 2125.30 | 14-JUL-17:07 | 861.63 | 24-JUL-17:20 | 762.51 | 26-JUL-17:00 | 0.00 | 01-JUL-00:10 |
| August | 0.587120E+10 | 0.145701E+10 | 744.00 | 0.368075E+10 | 0.219045E+10 | 0.00 | 0.57 | 13-AUG-15:10 | 0.24 | 20-AUG-04:00 | 3130.93 | 12-AUG-17:00 | 2087.54 | 01-AUG-16:03 | 1170.19 | 12-AUG-12:00 | 834.11 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.539205E+10 | 0.134543E+10 | 720.00 | 0.345981E+10 | 0.193223E+10 | 0.00 | 0.53 | 04-SEP-16:03 | 0.24 | 16-SEP-03:00 | 2883.78 | 04-SEP-16:03 | 1930.43 | 04-SEP-16:05 | 1073.06 | 25-SEP-11:50 | 769.61 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.514330E+10 | 0.127248E+10 | 744.00 | 0.329200E+10 | 0.185130E+10 | 0.00 | 0.49 | 29-OCT-13:00 | 0.23 | 23-OCT-04:00 | 2635.83 | 29-OCT-13:00 | 1796.27 | 04-OCT-15:10 | 938.85 | 16-OCT-13:00 | 696.71 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.466549E+10 | 0.116224E+10 | 720.00 | 0.311902E+10 | 0.154648E+10 | 0.00 | 0.47 | 10-NOV-13:40 | 0.17 | 25-NOV-06:05 | 2587.13 | 10-NOV-13:30 | 1722.38 | 18-NOV-13:00 | 958.99 | 10-NOV-13:40 | 674.23 | 10-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.433761E+10 | 0.108646E+10 | 744.00 | 0.303166E+10 | 0.130595E+10 | 0.00 | 0.44 | 09-DEC-14:00 | 0.08 | 21-DEC-06:05 | 2362.20 | 10-DEC-18:30 | 1650.79 | 09-DEC-14:00 | 832.83 | 10-DEC-18:50 | 620.56 | 29-DEC-19:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.630095E+11 | 0.158809E+11 | 8760.00 | 0.421520E+11 | 0.208575E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.421423E+10 | 0.107843E+10 | 672.00 | 0.303166E+10 | 0.115716E+10 | 0.00 | 0.44 | 0.08 | 2323.50 | 1650.79 | 720.88 | 620.56 | 0.00 | |||||||
| Maximum of Months | 0.647807E+10 | 0.163802E+10 | 744.00 | 0.417555E+10 | 0.234173E+10 | 0.00 | 0.66 | 0.28 | 3564.15 | 2467.21 | 1317.16 | 974.43 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.512408E+10 | 0.129347E+10 | 744.00 | 0.382820E+10 | 0.129588E+10 | 0.00 | 0.56 | 04-JAN-13:00 | 0.14 | 23-JAN-06:05 | 2888.86 | 04-JAN-13:00 | 2380.56 | 04-JAN-13:00 | 746.66 | 11-JAN-19:40 | 800.85 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.482114E+10 | 0.123031E+10 | 672.00 | 0.359220E+10 | 0.122894E+10 | 0.00 | 0.55 | 28-FEB-15:00 | 0.21 | 24-FEB-07:00 | 2861.97 | 28-FEB-15:00 | 2284.42 | 28-FEB-15:00 | 812.03 | 14-FEB-19:50 | 803.76 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.538122E+10 | 0.138271E+10 | 744.00 | 0.385643E+10 | 0.152479E+10 | 0.00 | 0.58 | 19-MAR-16:10 | 0.20 | 04-MAR-04:00 | 3048.04 | 19-MAR-16:10 | 2340.74 | 19-MAR-16:10 | 832.07 | 28-MAR-19:50 | 839.14 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.555933E+10 | 0.142867E+10 | 720.00 | 0.370934E+10 | 0.184999E+10 | 0.00 | 0.56 | 02-APR-16:10 | 0.26 | 23-APR-04:00 | 3035.64 | 02-APR-16:10 | 2099.33 | 01-APR-16:10 | 1036.40 | 10-APR-18:30 | 815.33 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.619075E+10 | 0.157201E+10 | 744.00 | 0.388210E+10 | 0.230865E+10 | 0.00 | 0.60 | 06-MAY-15:10 | 0.25 | 26-MAY-04:00 | 3165.55 | 06-MAY-16:10 | 2260.70 | 06-MAY-15:10 | 1206.80 | 21-MAY-09:00 | 893.62 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.601427E+10 | 0.152444E+10 | 720.00 | 0.377412E+10 | 0.224015E+10 | 0.00 | 0.59 | 11-JUN-16:02 | 0.26 | 27-JUN-05:00 | 3197.78 | 11-JUN-16:02 | 2124.96 | 13-JUN-16:10 | 1254.41 | 15-JUN-10:30 | 877.51 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.520528E+10 | 0.130579E+10 | 744.00 | 0.353561E+10 | 0.166967E+10 | 0.00 | 0.50 | 15-JUL-16:15 | 0.24 | 13-JUL-05:00 | 2662.30 | 15-JUL-16:15 | 1951.67 | 15-JUL-16:40 | 840.10 | 01-JUL-18:00 | 724.77 | 15-JUL-16:15 | 0.00 | 01-JUL-00:10 |
| August | 0.571715E+10 | 0.142028E+10 | 744.00 | 0.354841E+10 | 0.216874E+10 | 0.00 | 0.56 | 12-AUG-17:00 | 0.24 | 20-AUG-04:00 | 3084.28 | 12-AUG-17:00 | 1981.34 | 27-AUG-16:05 | 1179.27 | 12-AUG-12:00 | 815.30 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.546725E+10 | 0.136465E+10 | 720.00 | 0.351857E+10 | 0.194868E+10 | 0.00 | 0.54 | 04-SEP-16:03 | 0.24 | 16-SEP-03:00 | 2985.57 | 24-SEP-16:03 | 1984.36 | 04-SEP-16:05 | 1126.63 | 30-SEP-11:30 | 792.18 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.545763E+10 | 0.134999E+10 | 744.00 | 0.355400E+10 | 0.190363E+10 | 0.00 | 0.56 | 29-OCT-13:00 | 0.24 | 23-OCT-04:00 | 3085.67 | 29-OCT-13:00 | 2128.43 | 29-OCT-13:00 | 996.47 | 29-OCT-15:30 | 809.07 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.524794E+10 | 0.130549E+10 | 720.00 | 0.361885E+10 | 0.162910E+10 | 0.00 | 0.57 | 18-NOV-13:00 | 0.19 | 25-NOV-05:00 | 2984.89 | 18-NOV-13:00 | 2287.74 | 18-NOV-13:00 | 989.46 | 10-NOV-13:40 | 823.57 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.516260E+10 | 0.128979E+10 | 744.00 | 0.375023E+10 | 0.141237E+10 | 0.00 | 0.54 | 31-DEC-13:00 | 0.11 | 21-DEC-06:05 | 2895.67 | 31-DEC-13:00 | 2301.44 | 07-DEC-14:00 | 884.12 | 10-DEC-18:40 | 771.26 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.653486E+11 | 0.164676E+11 | 8760.00 | 0.441681E+11 | 0.211806E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.482114E+10 | 0.123031E+10 | 672.00 | 0.351857E+10 | 0.122894E+10 | 0.00 | 0.50 | 0.11 | 2662.30 | 1951.67 | 746.66 | 724.77 | 0.00 | |||||||
| Maximum of Months | 0.619075E+10 | 0.157201E+10 | 744.00 | 0.388210E+10 | 0.230865E+10 | 0.00 | 0.60 | 0.26 | 3197.78 | 2380.56 | 1254.41 | 893.62 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.550412E+10 | 0.138575E+10 | 744.00 | 0.416540E+10 | 0.133872E+10 | 0.00 | 0.57 | 04-JAN-13:00 | 0.17 | 23-JAN-06:05 | 3004.75 | 04-JAN-13:00 | 2493.58 | 04-JAN-13:00 | 767.47 | 11-JAN-19:40 | 831.03 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.515913E+10 | 0.131305E+10 | 672.00 | 0.389367E+10 | 0.126546E+10 | 0.00 | 0.57 | 28-FEB-15:00 | 0.24 | 24-FEB-07:00 | 2982.13 | 04-FEB-15:10 | 2414.83 | 26-FEB-15:00 | 834.13 | 14-FEB-19:50 | 831.48 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.574473E+10 | 0.147257E+10 | 744.00 | 0.417442E+10 | 0.157030E+10 | 0.00 | 0.61 | 19-MAR-16:10 | 0.22 | 04-MAR-04:00 | 3230.44 | 19-MAR-16:10 | 2506.28 | 19-MAR-16:10 | 855.28 | 28-MAR-19:50 | 885.91 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.593707E+10 | 0.152266E+10 | 720.00 | 0.403467E+10 | 0.190240E+10 | 0.00 | 0.59 | 02-APR-16:10 | 0.28 | 22-APR-02:30 | 3219.50 | 02-APR-16:10 | 2252.38 | 02-APR-16:02 | 1065.34 | 10-APR-18:30 | 861.98 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.658693E+10 | 0.166973E+10 | 744.00 | 0.421789E+10 | 0.236904E+10 | 0.00 | 0.62 | 06-MAY-15:10 | 0.28 | 26-MAY-04:00 | 3337.91 | 07-MAY-16:10 | 2412.48 | 06-MAY-15:10 | 1231.24 | 21-MAY-09:00 | 938.11 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.639363E+10 | 0.161768E+10 | 720.00 | 0.409585E+10 | 0.229779E+10 | 0.00 | 0.62 | 11-JUN-16:02 | 0.29 | 27-JUN-05:00 | 3384.60 | 11-JUN-16:02 | 2290.84 | 11-JUN-16:04 | 1269.36 | 15-JUN-10:30 | 914.90 | 11-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.558925E+10 | 0.139957E+10 | 744.00 | 0.386728E+10 | 0.172197E+10 | 0.00 | 0.53 | 15-JUL-16:15 | 0.26 | 20-JUL-04:00 | 2844.50 | 30-JUL-16:03 | 2093.45 | 15-JUL-16:40 | 862.14 | 01-JUL-18:20 | 764.56 | 15-JUL-16:15 | 0.00 | 01-JUL-00:10 |
| August | 0.609021E+10 | 0.151099E+10 | 744.00 | 0.386079E+10 | 0.222942E+10 | 0.00 | 0.59 | 13-AUG-15:10 | 0.26 | 20-AUG-04:00 | 3241.32 | 12-AUG-17:00 | 2142.02 | 27-AUG-16:05 | 1199.77 | 12-AUG-12:00 | 863.03 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.583960E+10 | 0.145538E+10 | 720.00 | 0.383617E+10 | 0.200343E+10 | 0.00 | 0.58 | 04-SEP-16:03 | 0.27 | 16-SEP-03:00 | 3167.54 | 04-SEP-16:03 | 2160.36 | 04-SEP-16:05 | 1145.55 | 30-SEP-11:30 | 841.21 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.583863E+10 | 0.144211E+10 | 744.00 | 0.387897E+10 | 0.195966E+10 | 0.00 | 0.59 | 29-OCT-13:00 | 0.27 | 27-OCT-04:00 | 3269.32 | 29-OCT-13:00 | 2292.50 | 29-OCT-13:00 | 1022.46 | 29-OCT-15:30 | 854.64 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.561259E+10 | 0.139359E+10 | 720.00 | 0.393606E+10 | 0.167652E+10 | 0.00 | 0.59 | 18-NOV-13:00 | 0.22 | 25-NOV-05:00 | 3130.75 | 18-NOV-13:00 | 2427.96 | 18-NOV-13:00 | 1001.87 | 10-NOV-13:40 | 861.44 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.552170E+10 | 0.137644E+10 | 744.00 | 0.406565E+10 | 0.145606E+10 | 0.00 | 0.57 | 31-DEC-13:00 | 0.13 | 21-DEC-06:05 | 3075.80 | 31-DEC-13:00 | 2389.79 | 31-DEC-13:00 | 909.48 | 10-DEC-18:40 | 816.44 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.698176E+11 | 0.175595E+11 | 8760.00 | 0.480268E+11 | 0.217908E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.515913E+10 | 0.131305E+10 | 672.00 | 0.383617E+10 | 0.126546E+10 | 0.00 | 0.53 | 0.13 | 2844.50 | 2093.45 | 767.47 | 764.56 | 0.00 | |||||||
| Maximum of Months | 0.658693E+10 | 0.166973E+10 | 744.00 | 0.421789E+10 | 0.236904E+10 | 0.00 | 0.62 | 0.29 | 3384.60 | 2506.28 | 1269.36 | 938.11 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.115873E+11 | 0.294494E+10 | 744.00 | 0.867084E+10 | 0.291642E+10 | 0.00 | 0.57 | 05-JAN-15:00 | 0.07 | 23-JAN-06:05 | 7457.65 | 05-JAN-15:00 | 6380.68 | 05-JAN-15:00 | 1933.53 | 11-JAN-19:30 | 2066.62 | 05-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.111131E+11 | 0.285509E+10 | 672.00 | 0.829878E+10 | 0.281435E+10 | 0.00 | 0.60 | 28-FEB-15:10 | 0.16 | 24-FEB-07:00 | 8086.69 | 28-FEB-15:10 | 6435.06 | 28-FEB-15:10 | 2089.12 | 14-FEB-19:40 | 2240.44 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.129927E+11 | 0.334909E+10 | 744.00 | 0.929303E+10 | 0.369970E+10 | 0.00 | 0.65 | 19-MAR-16:10 | 0.15 | 04-MAR-05:00 | 8925.55 | 19-MAR-16:10 | 6930.15 | 19-MAR-15:30 | 2170.98 | 28-MAR-19:40 | 2424.41 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.134018E+11 | 0.345639E+10 | 720.00 | 0.895938E+10 | 0.444244E+10 | 0.00 | 0.63 | 02-APR-16:10 | 0.20 | 23-APR-04:00 | 8769.72 | 02-APR-16:10 | 6164.77 | 02-APR-16:08 | 2818.78 | 29-APR-16:15 | 2332.41 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.146659E+11 | 0.373953E+10 | 744.00 | 0.911462E+10 | 0.555126E+10 | 0.00 | 0.67 | 06-MAY-15:10 | 0.19 | 26-MAY-04:00 | 9252.35 | 06-MAY-15:20 | 6644.76 | 06-MAY-15:10 | 3438.67 | 23-MAY-14:10 | 2586.04 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.142277E+11 | 0.362168E+10 | 720.00 | 0.884556E+10 | 0.538212E+10 | 0.00 | 0.64 | 16-JUN-15:30 | 0.20 | 27-JUN-05:00 | 9080.22 | 16-JUN-15:30 | 6024.40 | 16-JUN-16:10 | 3323.15 | 15-JUN-10:30 | 2419.19 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.118033E+11 | 0.297939E+10 | 744.00 | 0.798228E+10 | 0.382103E+10 | 0.00 | 0.55 | 04-JUL-16:10 | 0.17 | 13-JUL-05:00 | 7614.13 | 04-JUL-16:10 | 5423.10 | 04-JUL-16:07 | 2214.44 | 05-JUL-11:10 | 1981.46 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.132672E+11 | 0.330743E+10 | 744.00 | 0.809185E+10 | 0.517532E+10 | 0.00 | 0.59 | 12-AUG-16:15 | 0.17 | 20-AUG-04:00 | 8512.40 | 12-AUG-15:20 | 5635.96 | 27-AUG-16:05 | 3230.06 | 12-AUG-15:20 | 2206.14 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.124378E+11 | 0.312286E+10 | 720.00 | 0.796126E+10 | 0.447650E+10 | 0.00 | 0.58 | 04-SEP-16:03 | 0.18 | 16-SEP-03:00 | 8149.13 | 04-SEP-16:03 | 5584.71 | 10-SEP-15:00 | 2982.18 | 25-SEP-14:00 | 2160.42 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.123871E+11 | 0.308130E+10 | 744.00 | 0.803124E+10 | 0.435586E+10 | 0.00 | 0.59 | 29-OCT-13:00 | 0.17 | 23-OCT-05:00 | 8357.62 | 29-OCT-13:30 | 5752.96 | 28-OCT-15:10 | 2966.47 | 29-OCT-15:30 | 2167.58 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.117367E+11 | 0.293987E+10 | 720.00 | 0.808225E+10 | 0.365445E+10 | 0.00 | 0.57 | 04-NOV-15:20 | 0.12 | 25-NOV-05:00 | 7921.77 | 04-NOV-15:20 | 5839.88 | 19-NOV-14:20 | 2729.88 | 10-NOV-13:30 | 2063.30 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.114505E+11 | 0.288261E+10 | 744.00 | 0.832848E+10 | 0.312204E+10 | 0.00 | 0.53 | 07-DEC-14:20 | 0.05 | 21-DEC-06:05 | 7367.94 | 30-DEC-16:10 | 6036.24 | 07-DEC-14:30 | 2119.17 | 10-DEC-18:30 | 1934.89 | 07-DEC-14:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.151071E+12 | 0.382802E+11 | 8760.00 | 0.101660E+12 | 0.494115E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.111131E+11 | 0.285509E+10 | 672.00 | 0.796126E+10 | 0.281435E+10 | 0.00 | 0.53 | 0.05 | 7367.94 | 5423.10 | 1933.53 | 1934.89 | 0.00 | |||||||
| Maximum of Months | 0.146659E+11 | 0.373953E+10 | 744.00 | 0.929303E+10 | 0.555126E+10 | 0.00 | 0.67 | 0.20 | 9252.35 | 6930.15 | 3438.67 | 2586.04 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.991395E+10 | 0.252763E+10 | 744.00 | 0.718695E+10 | 0.272700E+10 | 0.00 | 0.46 | 05-JAN-15:00 | 0.05 | 23-JAN-06:05 | 6127.80 | 30-JAN-16:20 | 5017.59 | 31-JAN-16:10 | 1874.96 | 11-JAN-19:30 | 1684.35 | 05-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.988768E+10 | 0.254709E+10 | 672.00 | 0.720607E+10 | 0.268161E+10 | 0.00 | 0.53 | 28-FEB-15:10 | 0.14 | 24-FEB-07:00 | 7150.02 | 28-FEB-15:10 | 5537.80 | 28-FEB-15:10 | 2038.35 | 14-FEB-19:40 | 1994.34 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.124116E+11 | 0.320220E+10 | 744.00 | 0.877897E+10 | 0.363264E+10 | 0.00 | 0.60 | 19-MAR-16:10 | 0.15 | 04-MAR-05:00 | 8245.43 | 19-MAR-16:10 | 6287.21 | 19-MAR-15:40 | 2150.52 | 28-MAR-19:40 | 2255.11 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.134869E+11 | 0.347762E+10 | 720.00 | 0.903563E+10 | 0.445127E+10 | 0.00 | 0.61 | 02-APR-16:10 | 0.20 | 23-APR-04:00 | 8520.25 | 29-APR-16:15 | 6091.46 | 11-APR-16:10 | 2776.34 | 29-APR-16:15 | 2255.01 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.152111E+11 | 0.387536E+10 | 744.00 | 0.957831E+10 | 0.563280E+10 | 0.00 | 0.70 | 06-MAY-15:10 | 0.19 | 26-MAY-04:00 | 9609.36 | 06-MAY-15:10 | 6986.14 | 06-MAY-15:10 | 3551.23 | 23-MAY-14:10 | 2685.24 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.151916E+11 | 0.386112E+10 | 720.00 | 0.966590E+10 | 0.552565E+10 | 0.00 | 0.70 | 16-JUN-15:30 | 0.21 | 27-JUN-05:00 | 10056.04 | 16-JUN-15:30 | 6850.73 | 16-JUN-16:10 | 3471.88 | 15-JUN-10:30 | 2640.87 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.123538E+11 | 0.311563E+10 | 744.00 | 0.846124E+10 | 0.389256E+10 | 0.00 | 0.58 | 04-JUL-16:10 | 0.18 | 13-JUL-05:00 | 8082.59 | 04-JUL-16:10 | 5880.79 | 14-JUL-17:07 | 2326.28 | 05-JUL-11:00 | 2096.93 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.135930E+11 | 0.338712E+10 | 744.00 | 0.835948E+10 | 0.523347E+10 | 0.00 | 0.61 | 01-AUG-15:10 | 0.17 | 20-AUG-04:00 | 8659.43 | 01-AUG-15:10 | 5788.20 | 01-AUG-16:03 | 3243.37 | 12-AUG-15:10 | 2281.66 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.122872E+11 | 0.308545E+10 | 720.00 | 0.783544E+10 | 0.445171E+10 | 0.00 | 0.57 | 04-SEP-16:03 | 0.18 | 16-SEP-03:00 | 7946.93 | 04-SEP-16:03 | 5464.20 | 02-SEP-16:40 | 2964.12 | 25-SEP-14:00 | 2111.65 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.117530E+11 | 0.292490E+10 | 744.00 | 0.749420E+10 | 0.425884E+10 | 0.00 | 0.55 | 04-OCT-16:03 | 0.17 | 23-OCT-05:00 | 7617.88 | 04-OCT-16:03 | 5357.31 | 04-OCT-16:03 | 2789.65 | 29-OCT-15:20 | 1996.80 | 04-OCT-15:20 | 0.00 | 01-OCT-00:10 |
| November | 0.105492E+11 | 0.264612E+10 | 720.00 | 0.705288E+10 | 0.349635E+10 | 0.00 | 0.49 | 04-NOV-15:10 | 0.11 | 25-NOV-06:05 | 6866.08 | 10-NOV-13:30 | 4780.48 | 03-NOV-16:03 | 2650.46 | 10-NOV-13:30 | 1777.73 | 10-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.975786E+10 | 0.246221E+10 | 744.00 | 0.684122E+10 | 0.291665E+10 | 0.00 | 0.45 | 30-DEC-16:10 | 0.03 | 21-DEC-06:05 | 6176.11 | 30-DEC-16:10 | 4495.18 | 07-DEC-15:30 | 2006.02 | 10-DEC-18:30 | 1619.96 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.146397E+12 | 0.371124E+11 | 8760.00 | 0.974963E+11 | 0.489006E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.975786E+10 | 0.246221E+10 | 672.00 | 0.684122E+10 | 0.268161E+10 | 0.00 | 0.45 | 0.03 | 6127.80 | 4495.18 | 1874.96 | 1619.96 | 0.00 | |||||||
| Maximum of Months | 0.152111E+11 | 0.387536E+10 | 744.00 | 0.966590E+10 | 0.563280E+10 | 0.00 | 0.70 | 0.21 | 10056.04 | 6986.14 | 3551.23 | 2685.24 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.116090E+11 | 0.294409E+10 | 744.00 | 0.865154E+10 | 0.295749E+10 | 0.00 | 0.59 | 04-JAN-13:00 | 0.07 | 23-JAN-06:05 | 7525.61 | 04-JAN-13:00 | 6212.61 | 04-JAN-13:00 | 1935.48 | 11-JAN-19:30 | 2075.56 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.111581E+11 | 0.285939E+10 | 672.00 | 0.830599E+10 | 0.285207E+10 | 0.00 | 0.59 | 28-FEB-15:00 | 0.16 | 03-FEB-06:05 | 7532.56 | 28-FEB-15:00 | 5967.21 | 28-FEB-15:00 | 2094.33 | 14-FEB-19:40 | 2101.47 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.129771E+11 | 0.333961E+10 | 744.00 | 0.924395E+10 | 0.373315E+10 | 0.00 | 0.63 | 19-MAR-16:10 | 0.16 | 04-MAR-05:00 | 8226.83 | 19-MAR-16:10 | 6177.92 | 19-MAR-16:10 | 2199.18 | 25-MAR-08:40 | 2241.54 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.134377E+11 | 0.345917E+10 | 720.00 | 0.895944E+10 | 0.447829E+10 | 0.00 | 0.58 | 02-APR-16:10 | 0.21 | 23-APR-04:00 | 7805.55 | 02-APR-16:10 | 5437.42 | 01-APR-16:10 | 2696.31 | 29-APR-16:15 | 2091.57 | 01-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.147351E+11 | 0.374924E+10 | 744.00 | 0.914411E+10 | 0.559095E+10 | 0.00 | 0.65 | 06-MAY-15:10 | 0.20 | 26-MAY-04:00 | 8527.65 | 06-MAY-15:10 | 6058.02 | 06-MAY-15:10 | 3377.32 | 22-MAY-10:00 | 2399.53 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.143049E+11 | 0.363345E+10 | 720.00 | 0.888144E+10 | 0.542346E+10 | 0.00 | 0.62 | 11-JUN-10:00 | 0.21 | 27-JUN-05:00 | 8521.73 | 11-JUN-10:00 | 5445.72 | 13-JUN-15:10 | 3433.80 | 15-JUN-10:20 | 2262.85 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.118586E+11 | 0.298779E+10 | 744.00 | 0.799812E+10 | 0.386051E+10 | 0.00 | 0.52 | 01-JUL-13:00 | 0.18 | 13-JUL-05:00 | 6809.81 | 01-JUL-13:00 | 4791.12 | 01-JUL-13:00 | 2305.13 | 05-JUL-10:50 | 1828.35 | 28-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.133510E+11 | 0.332244E+10 | 744.00 | 0.813191E+10 | 0.521907E+10 | 0.00 | 0.58 | 12-AUG-12:00 | 0.18 | 20-AUG-04:00 | 8029.48 | 12-AUG-12:00 | 4985.69 | 13-AUG-15:10 | 3217.12 | 12-AUG-12:00 | 2107.24 | 12-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 0.125194E+11 | 0.313783E+10 | 720.00 | 0.800393E+10 | 0.451548E+10 | 0.00 | 0.56 | 02-SEP-14:00 | 0.19 | 16-SEP-03:00 | 7692.51 | 25-SEP-12:00 | 5044.44 | 02-SEP-14:00 | 2961.81 | 25-SEP-12:00 | 2018.38 | 02-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.124231E+11 | 0.308525E+10 | 744.00 | 0.803419E+10 | 0.438895E+10 | 0.00 | 0.61 | 29-OCT-13:00 | 0.18 | 23-OCT-05:00 | 8278.96 | 29-OCT-13:00 | 5589.67 | 29-OCT-13:00 | 2837.84 | 29-OCT-15:20 | 2149.38 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.117793E+11 | 0.294476E+10 | 720.00 | 0.808913E+10 | 0.369017E+10 | 0.00 | 0.57 | 18-NOV-13:00 | 0.13 | 25-NOV-05:00 | 7484.73 | 10-NOV-13:20 | 5758.09 | 18-NOV-13:00 | 2707.28 | 10-NOV-13:30 | 2043.04 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.114810E+11 | 0.288446E+10 | 744.00 | 0.831995E+10 | 0.316106E+10 | 0.00 | 0.55 | 31-DEC-13:00 | 0.06 | 21-DEC-06:05 | 7231.40 | 31-DEC-13:00 | 5755.72 | 07-DEC-14:00 | 2116.45 | 10-DEC-18:30 | 1924.34 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.151634E+12 | 0.383475E+11 | 8760.00 | 0.101764E+12 | 0.498707E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.111581E+11 | 0.285939E+10 | 672.00 | 0.799812E+10 | 0.285207E+10 | 0.00 | 0.52 | 0.06 | 6809.81 | 4791.12 | 1935.48 | 1828.35 | 0.00 | |||||||
| Maximum of Months | 0.147351E+11 | 0.374924E+10 | 744.00 | 0.924395E+10 | 0.559095E+10 | 0.00 | 0.65 | 0.21 | 8527.65 | 6212.61 | 3433.80 | 2399.53 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.992875E+10 | 0.252609E+10 | 744.00 | 0.716933E+10 | 0.275942E+10 | 0.00 | 0.47 | 04-JAN-13:00 | 0.05 | 23-JAN-06:05 | 5922.67 | 04-JAN-13:00 | 4697.36 | 04-JAN-13:00 | 1872.02 | 11-JAN-19:30 | 1659.11 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.992588E+10 | 0.255063E+10 | 672.00 | 0.721406E+10 | 0.271182E+10 | 0.00 | 0.52 | 28-FEB-15:00 | 0.15 | 03-FEB-06:05 | 6583.19 | 28-FEB-15:00 | 5071.38 | 28-FEB-15:00 | 2039.51 | 14-FEB-19:40 | 1852.97 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.123860E+11 | 0.319040E+10 | 744.00 | 0.873043E+10 | 0.365558E+10 | 0.00 | 0.58 | 19-MAR-16:10 | 0.15 | 04-MAR-05:00 | 7547.79 | 19-MAR-16:10 | 5621.44 | 19-MAR-16:10 | 2125.49 | 28-MAR-19:40 | 2070.76 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.135136E+11 | 0.347749E+10 | 720.00 | 0.903556E+10 | 0.447800E+10 | 0.00 | 0.57 | 30-APR-16:10 | 0.20 | 23-APR-04:00 | 7728.87 | 30-APR-16:10 | 5308.08 | 11-APR-16:10 | 2655.10 | 29-APR-16:15 | 2024.62 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.152709E+11 | 0.388144E+10 | 744.00 | 0.960743E+10 | 0.566348E+10 | 0.00 | 0.68 | 06-MAY-15:10 | 0.20 | 26-MAY-04:00 | 8910.68 | 06-MAY-15:10 | 6393.59 | 06-MAY-15:10 | 3484.89 | 22-MAY-10:00 | 2497.52 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.152595E+11 | 0.386873E+10 | 720.00 | 0.970125E+10 | 0.555824E+10 | 0.00 | 0.68 | 13-JUN-15:10 | 0.22 | 27-JUN-05:00 | 9272.15 | 16-JUN-15:30 | 6197.45 | 13-JUN-15:10 | 3565.71 | 15-JUN-10:20 | 2484.27 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.124000E+11 | 0.312075E+10 | 744.00 | 0.847656E+10 | 0.392342E+10 | 0.00 | 0.54 | 28-JUL-13:00 | 0.19 | 13-JUL-05:00 | 7170.67 | 04-JUL-16:10 | 5211.81 | 13-JUL-16:05 | 2407.52 | 05-JUL-10:50 | 1912.11 | 28-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.136682E+11 | 0.339914E+10 | 744.00 | 0.839952E+10 | 0.526872E+10 | 0.00 | 0.60 | 01-AUG-15:10 | 0.18 | 20-AUG-04:00 | 8135.60 | 01-AUG-15:10 | 5297.60 | 01-AUG-15:10 | 3229.62 | 07-AUG-12:10 | 2146.47 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.123610E+11 | 0.309818E+10 | 720.00 | 0.787841E+10 | 0.448254E+10 | 0.00 | 0.56 | 02-SEP-14:00 | 0.19 | 16-SEP-03:00 | 7488.82 | 25-SEP-12:00 | 4960.88 | 02-SEP-14:00 | 2943.59 | 25-SEP-12:00 | 1987.21 | 02-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.117812E+11 | 0.292716E+10 | 744.00 | 0.749771E+10 | 0.428351E+10 | 0.00 | 0.53 | 29-OCT-13:00 | 0.17 | 23-OCT-05:00 | 7224.86 | 29-OCT-13:00 | 4711.56 | 29-OCT-13:00 | 2647.88 | 29-OCT-15:20 | 1891.08 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.105850E+11 | 0.265009E+10 | 720.00 | 0.706085E+10 | 0.352419E+10 | 0.00 | 0.50 | 10-NOV-13:30 | 0.12 | 25-NOV-05:00 | 6865.45 | 10-NOV-13:30 | 4375.02 | 18-NOV-13:00 | 2620.57 | 10-NOV-13:30 | 1774.18 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.978192E+10 | 0.246357E+10 | 744.00 | 0.683411E+10 | 0.294781E+10 | 0.00 | 0.46 | 09-DEC-14:00 | 0.04 | 21-DEC-06:05 | 6071.95 | 09-DEC-14:00 | 4209.80 | 09-DEC-14:00 | 2002.59 | 10-DEC-18:40 | 1594.01 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.146862E+12 | 0.371537E+11 | 8760.00 | 0.976052E+11 | 0.492567E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.978192E+10 | 0.246357E+10 | 672.00 | 0.683411E+10 | 0.271182E+10 | 0.00 | 0.46 | 0.04 | 5922.67 | 4209.80 | 1872.02 | 1594.01 | 0.00 | |||||||
| Maximum of Months | 0.152709E+11 | 0.388144E+10 | 744.00 | 0.970125E+10 | 0.566348E+10 | 0.00 | 0.68 | 0.22 | 9272.15 | 6393.59 | 3565.71 | 2497.52 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.848841E+10 | 0.215850E+10 | 744.00 | 0.605621E+10 | 0.243220E+10 | 0.00 | 0.41 | 04-JAN-13:00 | 0.07 | 23-JAN-06:05 | 4784.23 | 11-JAN-17:10 | 3582.24 | 04-JAN-13:00 | 1553.36 | 11-JAN-19:40 | 1298.29 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.832906E+10 | 0.214081E+10 | 672.00 | 0.596632E+10 | 0.236274E+10 | 0.00 | 0.45 | 28-FEB-15:00 | 0.15 | 24-FEB-07:00 | 5095.44 | 28-FEB-15:10 | 3883.01 | 28-FEB-15:00 | 1692.96 | 14-FEB-19:40 | 1447.12 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.101925E+11 | 0.263018E+10 | 744.00 | 0.710181E+10 | 0.309070E+10 | 0.00 | 0.51 | 19-MAR-16:10 | 0.16 | 04-MAR-04:00 | 5831.50 | 19-MAR-16:10 | 4362.87 | 19-MAR-16:10 | 1762.45 | 28-MAR-19:50 | 1619.43 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.111803E+11 | 0.288243E+10 | 720.00 | 0.734687E+10 | 0.383339E+10 | 0.00 | 0.52 | 30-APR-16:15 | 0.22 | 23-APR-04:00 | 6217.58 | 29-APR-16:15 | 4217.05 | 11-APR-16:04 | 2212.80 | 10-APR-18:00 | 1635.93 | 30-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.128583E+11 | 0.327393E+10 | 744.00 | 0.799068E+10 | 0.486765E+10 | 0.00 | 0.60 | 06-MAY-15:10 | 0.22 | 26-MAY-04:00 | 6963.77 | 06-MAY-15:10 | 4970.56 | 06-MAY-15:10 | 2726.29 | 23-MAY-14:10 | 1976.47 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.128439E+11 | 0.326318E+10 | 720.00 | 0.806676E+10 | 0.477715E+10 | 0.00 | 0.62 | 13-JUN-16:03 | 0.23 | 27-JUN-05:00 | 7373.37 | 13-JUN-16:03 | 5008.12 | 13-JUN-16:03 | 2855.37 | 15-JUN-10:30 | 2028.49 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.106545E+11 | 0.268161E+10 | 744.00 | 0.720014E+10 | 0.345434E+10 | 0.00 | 0.50 | 04-JUL-16:10 | 0.20 | 13-JUL-05:00 | 5926.48 | 04-JUL-16:10 | 4279.91 | 14-JUL-17:03 | 1856.60 | 05-JUL-11:20 | 1555.04 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.115590E+11 | 0.287850E+10 | 744.00 | 0.703483E+10 | 0.452421E+10 | 0.00 | 0.54 | 01-AUG-15:10 | 0.20 | 20-AUG-04:00 | 6493.56 | 09-AUG-16:10 | 4225.47 | 01-AUG-16:03 | 2559.78 | 12-AUG-12:00 | 1726.70 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.105257E+11 | 0.263720E+10 | 720.00 | 0.658968E+10 | 0.393601E+10 | 0.00 | 0.49 | 04-SEP-16:03 | 0.20 | 16-SEP-03:00 | 5866.79 | 04-SEP-16:03 | 3840.28 | 04-SEP-16:03 | 2338.98 | 25-SEP-12:00 | 1572.10 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.101745E+11 | 0.252590E+10 | 744.00 | 0.638772E+10 | 0.378683E+10 | 0.00 | 0.46 | 29-OCT-13:00 | 0.19 | 23-OCT-04:00 | 5570.85 | 29-OCT-13:00 | 3664.28 | 04-OCT-15:10 | 2052.90 | 29-OCT-15:20 | 1473.41 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.916773E+10 | 0.229258E+10 | 720.00 | 0.602763E+10 | 0.314010E+10 | 0.00 | 0.45 | 10-NOV-13:30 | 0.13 | 25-NOV-06:05 | 5399.23 | 10-NOV-13:30 | 3463.33 | 18-NOV-13:00 | 2085.36 | 10-NOV-13:30 | 1407.04 | 10-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.848068E+10 | 0.213260E+10 | 744.00 | 0.584511E+10 | 0.263557E+10 | 0.00 | 0.41 | 09-DEC-14:00 | 0.05 | 21-DEC-06:05 | 4848.78 | 09-DEC-14:00 | 3350.29 | 09-DEC-14:00 | 1740.14 | 10-DEC-18:50 | 1281.75 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.124455E+12 | 0.314974E+11 | 8760.00 | 0.816138E+11 | 0.428409E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.832906E+10 | 0.213260E+10 | 672.00 | 0.584511E+10 | 0.236274E+10 | 0.00 | 0.41 | 0.05 | 4784.23 | 3350.29 | 1553.36 | 1281.75 | 0.00 | |||||||
| Maximum of Months | 0.128583E+11 | 0.327393E+10 | 744.00 | 0.806676E+10 | 0.486765E+10 | 0.00 | 0.62 | 0.23 | 7373.37 | 5008.12 | 2855.37 | 2028.49 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.848924E+10 | 0.215865E+10 | 744.00 | 0.605654E+10 | 0.243270E+10 | 0.00 | 0.41 | 04-JAN-13:00 | 0.07 | 23-JAN-06:05 | 4779.99 | 11-JAN-17:10 | 3590.94 | 04-JAN-13:00 | 1553.11 | 11-JAN-19:40 | 1300.68 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.833052E+10 | 0.214111E+10 | 672.00 | 0.596723E+10 | 0.236329E+10 | 0.00 | 0.45 | 28-FEB-15:00 | 0.15 | 24-FEB-07:00 | 5093.04 | 28-FEB-15:10 | 3882.53 | 28-FEB-15:00 | 1692.93 | 14-FEB-19:40 | 1446.70 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.101918E+11 | 0.262995E+10 | 744.00 | 0.710092E+10 | 0.309084E+10 | 0.00 | 0.50 | 19-MAR-16:10 | 0.16 | 04-MAR-04:00 | 5821.09 | 19-MAR-16:10 | 4353.96 | 19-MAR-16:10 | 1761.36 | 28-MAR-19:50 | 1616.62 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.111812E+11 | 0.288258E+10 | 720.00 | 0.734740E+10 | 0.383380E+10 | 0.00 | 0.52 | 30-APR-16:15 | 0.22 | 23-APR-04:00 | 6206.25 | 29-APR-16:15 | 4210.10 | 11-APR-16:04 | 2213.22 | 10-APR-18:00 | 1633.44 | 30-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.128602E+11 | 0.327426E+10 | 744.00 | 0.799199E+10 | 0.486822E+10 | 0.00 | 0.60 | 06-MAY-15:10 | 0.22 | 26-MAY-04:00 | 6959.40 | 06-MAY-15:10 | 4967.52 | 06-MAY-15:10 | 2725.29 | 23-MAY-14:10 | 1975.18 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.128460E+11 | 0.326356E+10 | 720.00 | 0.806827E+10 | 0.477777E+10 | 0.00 | 0.62 | 13-JUN-16:03 | 0.23 | 27-JUN-05:00 | 7363.77 | 13-JUN-16:03 | 5000.35 | 13-JUN-16:03 | 2857.89 | 15-JUN-10:30 | 2027.10 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.106561E+11 | 0.268190E+10 | 744.00 | 0.720112E+10 | 0.345497E+10 | 0.00 | 0.50 | 04-JUL-16:10 | 0.20 | 13-JUL-05:00 | 5913.34 | 04-JUL-16:10 | 4268.69 | 14-JUL-17:03 | 1858.21 | 05-JUL-11:20 | 1552.56 | 26-JUL-17:00 | 0.00 | 01-JUL-00:10 |
| August | 0.115616E+11 | 0.287901E+10 | 744.00 | 0.703658E+10 | 0.452501E+10 | 0.00 | 0.54 | 01-AUG-15:10 | 0.20 | 20-AUG-04:00 | 6487.87 | 09-AUG-16:10 | 4220.69 | 01-AUG-16:03 | 2560.47 | 12-AUG-12:00 | 1726.25 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.105284E+11 | 0.263778E+10 | 720.00 | 0.659163E+10 | 0.393677E+10 | 0.00 | 0.49 | 04-SEP-16:03 | 0.20 | 16-SEP-03:00 | 5859.44 | 04-SEP-16:03 | 3835.05 | 04-SEP-16:03 | 2339.94 | 25-SEP-12:00 | 1570.16 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.101754E+11 | 0.252603E+10 | 744.00 | 0.638811E+10 | 0.378728E+10 | 0.00 | 0.47 | 29-OCT-13:00 | 0.19 | 23-OCT-04:00 | 5573.73 | 29-OCT-13:00 | 3660.18 | 04-OCT-15:10 | 2051.56 | 29-OCT-15:20 | 1474.07 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.916904E+10 | 0.229282E+10 | 720.00 | 0.602839E+10 | 0.314065E+10 | 0.00 | 0.45 | 10-NOV-13:30 | 0.13 | 25-NOV-06:05 | 5405.91 | 10-NOV-13:30 | 3467.44 | 18-NOV-13:00 | 2086.09 | 10-NOV-13:30 | 1408.53 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.848158E+10 | 0.213277E+10 | 744.00 | 0.584553E+10 | 0.263605E+10 | 0.00 | 0.41 | 09-DEC-14:00 | 0.05 | 21-DEC-06:05 | 4848.95 | 09-DEC-14:00 | 3350.57 | 09-DEC-14:00 | 1739.84 | 10-DEC-18:50 | 1281.73 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.124471E+12 | 0.315004E+11 | 8760.00 | 0.816237E+11 | 0.428473E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.833052E+10 | 0.213277E+10 | 672.00 | 0.584553E+10 | 0.236329E+10 | 0.00 | 0.41 | 0.05 | 4779.99 | 3350.57 | 1553.11 | 1281.73 | 0.00 | |||||||
| Maximum of Months | 0.128602E+11 | 0.327426E+10 | 744.00 | 0.806827E+10 | 0.486822E+10 | 0.00 | 0.62 | 0.23 | 7363.77 | 5000.35 | 2857.89 | 2027.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.101873E+11 | 0.258361E+10 | 744.00 | 0.754902E+10 | 0.263825E+10 | 0.00 | 0.54 | 04-JAN-13:00 | 0.09 | 23-JAN-06:05 | 6182.23 | 04-JAN-13:00 | 5080.35 | 04-JAN-13:00 | 1606.78 | 11-JAN-19:40 | 1716.95 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.957623E+10 | 0.245595E+10 | 672.00 | 0.706574E+10 | 0.251049E+10 | 0.00 | 0.53 | 28-FEB-15:00 | 0.17 | 24-FEB-07:00 | 6033.86 | 28-FEB-15:00 | 4772.98 | 28-FEB-15:00 | 1739.25 | 14-FEB-19:40 | 1698.90 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.107856E+11 | 0.278178E+10 | 744.00 | 0.761846E+10 | 0.316710E+10 | 0.00 | 0.56 | 19-MAR-16:10 | 0.17 | 04-MAR-05:00 | 6499.59 | 19-MAR-16:10 | 4918.74 | 19-MAR-16:10 | 1784.26 | 28-MAR-19:50 | 1791.70 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.110965E+11 | 0.286200E+10 | 720.00 | 0.726956E+10 | 0.382697E+10 | 0.00 | 0.53 | 02-APR-16:10 | 0.22 | 23-APR-04:00 | 6322.07 | 02-APR-16:10 | 4334.00 | 01-APR-16:10 | 2211.17 | 29-APR-16:15 | 1702.81 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.123073E+11 | 0.313647E+10 | 744.00 | 0.752327E+10 | 0.478401E+10 | 0.00 | 0.57 | 06-MAY-15:10 | 0.21 | 26-MAY-04:00 | 6576.81 | 06-MAY-15:10 | 4634.34 | 06-MAY-15:10 | 2608.47 | 23-MAY-14:10 | 1874.95 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.118667E+11 | 0.301947E+10 | 720.00 | 0.724017E+10 | 0.462656E+10 | 0.00 | 0.55 | 11-JUN-16:02 | 0.22 | 27-JUN-05:00 | 6531.65 | 11-JUN-16:02 | 4241.42 | 11-JUN-16:10 | 2704.65 | 15-JUN-10:30 | 1802.04 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.100970E+11 | 0.254369E+10 | 744.00 | 0.671640E+10 | 0.338055E+10 | 0.00 | 0.46 | 15-JUL-16:02 | 0.20 | 20-JUL-04:00 | 5455.91 | 04-JUL-16:10 | 3881.08 | 15-JUL-16:20 | 1783.48 | 29-JUL-12:20 | 1467.70 | 15-JUL-16:02 | 0.00 | 01-JUL-00:10 |
| August | 0.112308E+11 | 0.279833E+10 | 744.00 | 0.676408E+10 | 0.446668E+10 | 0.00 | 0.52 | 12-AUG-12:00 | 0.20 | 20-AUG-04:00 | 6332.49 | 12-AUG-12:00 | 3976.89 | 27-AUG-16:05 | 2574.09 | 12-AUG-12:00 | 1677.83 | 12-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 0.106806E+11 | 0.267642E+10 | 720.00 | 0.671456E+10 | 0.396600E+10 | 0.00 | 0.51 | 24-SEP-16:03 | 0.20 | 16-SEP-03:00 | 6183.42 | 24-SEP-16:03 | 3982.54 | 30-SEP-14:00 | 2355.16 | 25-SEP-12:00 | 1621.10 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.108216E+11 | 0.268648E+10 | 744.00 | 0.692748E+10 | 0.389416E+10 | 0.00 | 0.55 | 29-OCT-13:00 | 0.20 | 23-OCT-04:00 | 6612.91 | 29-OCT-13:00 | 4482.86 | 29-OCT-13:00 | 2235.12 | 29-OCT-15:30 | 1734.46 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.103770E+11 | 0.259261E+10 | 720.00 | 0.706353E+10 | 0.331345E+10 | 0.00 | 0.54 | 18-NOV-13:00 | 0.15 | 25-NOV-05:00 | 6302.30 | 18-NOV-13:00 | 4832.40 | 18-NOV-13:00 | 2167.41 | 10-NOV-13:30 | 1744.43 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.102003E+11 | 0.256059E+10 | 744.00 | 0.734208E+10 | 0.285823E+10 | 0.00 | 0.52 | 31-DEC-13:00 | 0.08 | 21-DEC-06:05 | 6071.71 | 31-DEC-13:00 | 4863.83 | 07-DEC-14:00 | 1845.13 | 10-DEC-18:40 | 1622.37 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.129227E+12 | 0.326974E+11 | 8760.00 | 0.857944E+11 | 0.434325E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.957623E+10 | 0.245595E+10 | 672.00 | 0.671456E+10 | 0.251049E+10 | 0.00 | 0.46 | 0.08 | 5455.91 | 3881.08 | 1606.78 | 1467.70 | 0.00 | |||||||
| Maximum of Months | 0.123073E+11 | 0.313647E+10 | 744.00 | 0.761846E+10 | 0.478401E+10 | 0.00 | 0.57 | 0.22 | 6612.91 | 5080.35 | 2704.65 | 1874.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.101880E+11 | 0.258368E+10 | 744.00 | 0.754921E+10 | 0.263876E+10 | 0.00 | 0.54 | 04-JAN-13:00 | 0.09 | 23-JAN-06:05 | 6191.09 | 04-JAN-13:00 | 5088.96 | 04-JAN-13:00 | 1606.58 | 11-JAN-19:40 | 1719.13 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.957753E+10 | 0.245616E+10 | 672.00 | 0.706653E+10 | 0.251100E+10 | 0.00 | 0.53 | 28-FEB-15:00 | 0.17 | 24-FEB-07:00 | 6032.30 | 28-FEB-15:00 | 4772.11 | 28-FEB-15:00 | 1739.24 | 14-FEB-19:40 | 1698.39 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.107848E+11 | 0.278153E+10 | 744.00 | 0.761752E+10 | 0.316728E+10 | 0.00 | 0.56 | 19-MAR-16:10 | 0.17 | 04-MAR-05:00 | 6488.96 | 19-MAR-16:10 | 4909.46 | 19-MAR-16:10 | 1783.20 | 28-MAR-19:50 | 1788.85 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.110975E+11 | 0.286216E+10 | 720.00 | 0.727007E+10 | 0.382741E+10 | 0.00 | 0.53 | 02-APR-16:10 | 0.22 | 23-APR-04:00 | 6309.12 | 02-APR-16:10 | 4326.25 | 01-APR-16:10 | 2208.35 | 29-APR-16:15 | 1699.43 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.123092E+11 | 0.313685E+10 | 744.00 | 0.752459E+10 | 0.478464E+10 | 0.00 | 0.57 | 06-MAY-15:10 | 0.21 | 26-MAY-04:00 | 6572.52 | 06-MAY-15:10 | 4631.43 | 06-MAY-15:10 | 2607.47 | 23-MAY-14:10 | 1873.70 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.118690E+11 | 0.301991E+10 | 720.00 | 0.724172E+10 | 0.462725E+10 | 0.00 | 0.55 | 11-JUN-16:02 | 0.22 | 27-JUN-05:00 | 6521.85 | 11-JUN-16:02 | 4233.80 | 11-JUN-16:10 | 2707.60 | 15-JUN-10:30 | 1800.69 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.100986E+11 | 0.254402E+10 | 744.00 | 0.671740E+10 | 0.338122E+10 | 0.00 | 0.46 | 15-JUL-16:02 | 0.20 | 20-JUL-04:00 | 5442.59 | 04-JUL-16:10 | 3877.18 | 15-JUL-16:20 | 1784.50 | 29-JUL-12:20 | 1466.49 | 15-JUL-16:02 | 0.00 | 01-JUL-00:10 |
| August | 0.112334E+11 | 0.279888E+10 | 744.00 | 0.676584E+10 | 0.446752E+10 | 0.00 | 0.52 | 12-AUG-12:00 | 0.20 | 20-AUG-04:00 | 6336.17 | 12-AUG-12:00 | 3968.95 | 27-AUG-16:05 | 2574.81 | 12-AUG-12:00 | 1678.65 | 12-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 0.106833E+11 | 0.267700E+10 | 720.00 | 0.671648E+10 | 0.396678E+10 | 0.00 | 0.51 | 24-SEP-16:03 | 0.20 | 16-SEP-03:00 | 6176.84 | 24-SEP-16:03 | 3979.57 | 30-SEP-14:00 | 2356.08 | 25-SEP-12:00 | 1619.13 | 04-SEP-16:03 | 0.00 | 01-SEP-00:10 |
| October | 0.108225E+11 | 0.268658E+10 | 744.00 | 0.692782E+10 | 0.389463E+10 | 0.00 | 0.55 | 29-OCT-13:00 | 0.20 | 23-OCT-04:00 | 6615.72 | 29-OCT-13:00 | 4485.69 | 29-OCT-13:00 | 2233.73 | 29-OCT-15:30 | 1735.05 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.103782E+11 | 0.259280E+10 | 720.00 | 0.706419E+10 | 0.331398E+10 | 0.00 | 0.55 | 18-NOV-13:00 | 0.15 | 25-NOV-05:00 | 6306.03 | 18-NOV-13:00 | 4836.37 | 18-NOV-13:00 | 2168.03 | 10-NOV-13:30 | 1745.29 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.102011E+11 | 0.256068E+10 | 744.00 | 0.734236E+10 | 0.285871E+10 | 0.00 | 0.52 | 31-DEC-13:00 | 0.08 | 21-DEC-06:05 | 6079.23 | 31-DEC-13:00 | 4865.26 | 07-DEC-14:00 | 1844.90 | 10-DEC-18:40 | 1624.17 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.129243E+12 | 0.327002E+11 | 8760.00 | 0.858037E+11 | 0.434392E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.957753E+10 | 0.245616E+10 | 672.00 | 0.671648E+10 | 0.251100E+10 | 0.00 | 0.46 | 0.08 | 5442.59 | 3877.18 | 1606.58 | 1466.49 | 0.00 | |||||||
| Maximum of Months | 0.123092E+11 | 0.313685E+10 | 744.00 | 0.761752E+10 | 0.478464E+10 | 0.00 | 0.57 | 0.22 | 6615.72 | 5088.96 | 2707.60 | 1873.70 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.627364E+10 | 0.159723E+10 | 742.47 | 0.475460E+10 | 0.151904E+10 | 0.00 | 0.67 | 05-JAN-15:00 | 0.00 | 21-JAN-06:05 | 4884.29 | 05-JAN-15:00 | 4256.29 | 05-JAN-15:00 | 1107.55 | 11-JAN-11:00 | 1332.46 | 05-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.610456E+10 | 0.157038E+10 | 672.00 | 0.461074E+10 | 0.149382E+10 | 0.00 | 0.72 | 28-FEB-15:10 | 0.08 | 03-FEB-06:05 | 5317.46 | 28-FEB-15:10 | 4321.08 | 28-FEB-15:10 | 1181.71 | 18-FEB-11:10 | 1448.57 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.731888E+10 | 0.188657E+10 | 744.00 | 0.529971E+10 | 0.201917E+10 | 0.00 | 0.77 | 19-MAR-15:50 | 0.09 | 04-MAR-05:00 | 5840.82 | 19-MAR-16:10 | 4687.47 | 19-MAR-15:30 | 1296.17 | 19-MAR-16:10 | 1566.35 | 19-MAR-15:50 | 0.00 | 01-MAR-00:10 |
| April | 0.762653E+10 | 0.196580E+10 | 720.00 | 0.518156E+10 | 0.244496E+10 | 0.00 | 0.73 | 02-APR-16:10 | 0.15 | 23-APR-04:00 | 5656.72 | 02-APR-16:10 | 4128.40 | 01-APR-16:10 | 1662.65 | 29-APR-16:15 | 1483.03 | 02-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.829475E+10 | 0.211458E+10 | 744.00 | 0.523158E+10 | 0.306316E+10 | 0.00 | 0.80 | 06-MAY-15:20 | 0.13 | 26-MAY-04:00 | 6075.66 | 06-MAY-15:20 | 4489.42 | 06-MAY-15:10 | 2110.68 | 23-MAY-14:20 | 1665.64 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.808187E+10 | 0.205629E+10 | 720.00 | 0.510372E+10 | 0.297815E+10 | 0.00 | 0.75 | 16-JUN-15:30 | 0.15 | 27-JUN-05:00 | 5904.89 | 16-JUN-15:30 | 3983.24 | 13-JUN-15:10 | 2007.09 | 15-JUN-10:20 | 1540.62 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.656471E+10 | 0.165813E+10 | 744.00 | 0.449355E+10 | 0.207116E+10 | 0.00 | 0.64 | 04-JUL-16:10 | 0.12 | 13-JUL-05:00 | 4904.85 | 04-JUL-16:10 | 3585.05 | 04-JUL-16:10 | 1367.46 | 05-JUL-10:50 | 1260.76 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.737184E+10 | 0.183713E+10 | 744.00 | 0.453132E+10 | 0.284052E+10 | 0.00 | 0.69 | 12-AUG-15:20 | 0.12 | 20-AUG-04:00 | 5449.56 | 12-AUG-15:20 | 3731.53 | 27-AUG-16:05 | 1958.39 | 12-AUG-12:10 | 1401.50 | 13-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.692396E+10 | 0.173915E+10 | 720.00 | 0.449644E+10 | 0.242753E+10 | 0.00 | 0.69 | 10-SEP-15:10 | 0.14 | 16-SEP-03:00 | 5389.17 | 10-SEP-15:10 | 3813.92 | 10-SEP-15:00 | 1801.03 | 25-SEP-14:00 | 1372.86 | 10-SEP-15:00 | 0.00 | 01-SEP-00:10 |
| October | 0.675340E+10 | 0.168092E+10 | 744.00 | 0.442136E+10 | 0.233204E+10 | 0.00 | 0.69 | 29-OCT-13:20 | 0.12 | 12-OCT-04:00 | 5373.73 | 29-OCT-13:30 | 3867.50 | 28-OCT-15:10 | 1793.00 | 29-OCT-15:20 | 1371.60 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.635919E+10 | 0.159485E+10 | 720.00 | 0.442967E+10 | 0.192952E+10 | 0.00 | 0.65 | 18-NOV-13:00 | 0.06 | 25-NOV-06:05 | 5030.51 | 04-NOV-15:20 | 3933.08 | 19-NOV-14:10 | 1653.57 | 10-NOV-13:30 | 1318.19 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.612410E+10 | 0.154524E+10 | 740.75 | 0.451624E+10 | 0.160786E+10 | 0.00 | 0.64 | 07-DEC-14:20 | 0.00 | 21-DEC-04:30 | 4714.04 | 30-DEC-14:30 | 4052.86 | 07-DEC-14:20 | 1275.09 | 09-DEC-15:10 | 1254.23 | 07-DEC-14:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.837974E+11 | 0.212463E+11 | 8755.22 | 0.570705E+11 | 0.267269E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.610456E+10 | 0.154524E+10 | 672.00 | 0.442136E+10 | 0.149382E+10 | 0.00 | 0.64 | 0.00 | 4714.04 | 3585.05 | 1107.55 | 1254.23 | 0.00 | |||||||
| Maximum of Months | 0.829475E+10 | 0.211458E+10 | 744.00 | 0.529971E+10 | 0.306316E+10 | 0.00 | 0.80 | 0.15 | 6075.66 | 4687.47 | 2110.68 | 1665.64 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.537332E+10 | 0.137500E+10 | 740.67 | 0.394716E+10 | 0.142616E+10 | 0.00 | 0.55 | 05-JAN-15:00 | 0.00 | 21-JAN-06:05 | 3968.51 | 03-JAN-14:20 | 3358.35 | 31-JAN-16:10 | 1082.76 | 11-JAN-17:10 | 1099.05 | 05-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.544854E+10 | 0.140763E+10 | 672.00 | 0.401838E+10 | 0.143016E+10 | 0.00 | 0.64 | 28-FEB-15:10 | 0.07 | 24-FEB-07:00 | 4733.23 | 28-FEB-15:20 | 3754.56 | 28-FEB-15:10 | 1153.03 | 14-FEB-19:30 | 1300.12 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.701075E+10 | 0.181027E+10 | 744.00 | 0.502269E+10 | 0.198806E+10 | 0.00 | 0.72 | 19-MAR-16:10 | 0.09 | 04-MAR-05:00 | 5430.02 | 19-MAR-16:10 | 4276.36 | 19-MAR-15:40 | 1281.59 | 28-MAR-17:10 | 1460.40 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.767774E+10 | 0.197921E+10 | 720.00 | 0.522785E+10 | 0.244990E+10 | 0.00 | 0.71 | 11-APR-16:10 | 0.15 | 23-APR-04:00 | 5468.68 | 02-APR-16:10 | 4114.96 | 11-APR-16:10 | 1641.01 | 29-APR-16:15 | 1449.09 | 11-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.859329E+10 | 0.218894E+10 | 744.00 | 0.549005E+10 | 0.310324E+10 | 0.00 | 0.82 | 06-MAY-15:10 | 0.13 | 26-MAY-04:00 | 6294.74 | 06-MAY-15:10 | 4709.13 | 06-MAY-15:10 | 2174.59 | 23-MAY-14:20 | 1726.72 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.860407E+10 | 0.218523E+10 | 720.00 | 0.555587E+10 | 0.304820E+10 | 0.00 | 0.81 | 16-JUN-15:30 | 0.15 | 27-JUN-05:00 | 6500.44 | 16-JUN-15:30 | 4479.05 | 16-JUN-16:03 | 2086.13 | 15-JUN-10:20 | 1673.07 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.686312E+10 | 0.173185E+10 | 744.00 | 0.475624E+10 | 0.210687E+10 | 0.00 | 0.67 | 04-JUL-16:10 | 0.12 | 13-JUL-05:00 | 5213.81 | 04-JUL-16:10 | 3885.40 | 04-JUL-16:10 | 1433.54 | 05-JUL-10:50 | 1335.27 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.754982E+10 | 0.188092E+10 | 744.00 | 0.467970E+10 | 0.287012E+10 | 0.00 | 0.72 | 01-AUG-15:10 | 0.12 | 20-AUG-04:00 | 5629.75 | 01-AUG-15:10 | 3856.99 | 01-AUG-15:10 | 1972.28 | 05-AUG-15:10 | 1463.37 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.684228E+10 | 0.171974E+10 | 720.00 | 0.442661E+10 | 0.241567E+10 | 0.00 | 0.67 | 10-SEP-15:00 | 0.14 | 16-SEP-03:00 | 5258.58 | 10-SEP-15:10 | 3725.83 | 10-SEP-15:00 | 1790.81 | 25-SEP-14:00 | 1352.90 | 10-SEP-15:00 | 0.00 | 01-SEP-00:10 |
| October | 0.641721E+10 | 0.159932E+10 | 744.00 | 0.413144E+10 | 0.228576E+10 | 0.00 | 0.64 | 04-OCT-15:20 | 0.12 | 12-OCT-04:00 | 4920.93 | 04-OCT-15:20 | 3564.91 | 04-OCT-15:20 | 1702.49 | 29-OCT-15:20 | 1285.77 | 04-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.572450E+10 | 0.143965E+10 | 720.00 | 0.387120E+10 | 0.185330E+10 | 0.00 | 0.56 | 04-NOV-15:10 | 0.05 | 25-NOV-06:05 | 4406.29 | 10-NOV-13:30 | 3124.50 | 04-NOV-15:20 | 1612.90 | 10-NOV-13:30 | 1130.50 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.521321E+10 | 0.132110E+10 | 739.17 | 0.370631E+10 | 0.150689E+10 | 0.00 | 0.51 | 30-DEC-16:10 | 0.00 | 15-DEC-06:05 | 3912.63 | 30-DEC-16:10 | 3046.47 | 07-DEC-15:20 | 1212.87 | 09-DEC-15:20 | 1017.54 | 30-DEC-14:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.813178E+11 | 0.206389E+11 | 8751.83 | 0.548335E+11 | 0.264843E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.521321E+10 | 0.132110E+10 | 672.00 | 0.370631E+10 | 0.142616E+10 | 0.00 | 0.51 | 0.00 | 3912.63 | 3046.47 | 1082.76 | 1017.54 | 0.00 | |||||||
| Maximum of Months | 0.860407E+10 | 0.218894E+10 | 744.00 | 0.555587E+10 | 0.310324E+10 | 0.00 | 0.82 | 0.15 | 6500.44 | 4709.13 | 2174.59 | 1726.72 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.628549E+10 | 0.159450E+10 | 742.67 | 0.473972E+10 | 0.154577E+10 | 0.00 | 0.71 | 04-JAN-13:00 | 0.00 | 21-JAN-06:05 | 4930.58 | 04-JAN-13:00 | 4149.10 | 04-JAN-13:00 | 1128.63 | 11-JAN-11:00 | 1335.03 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.613077E+10 | 0.157073E+10 | 672.00 | 0.461254E+10 | 0.151823E+10 | 0.00 | 0.71 | 28-FEB-15:00 | 0.09 | 03-FEB-06:05 | 4903.95 | 28-FEB-15:00 | 3963.17 | 28-FEB-15:00 | 1205.05 | 18-FEB-11:10 | 1344.13 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.730680E+10 | 0.187791E+10 | 744.00 | 0.526529E+10 | 0.204151E+10 | 0.00 | 0.74 | 19-MAR-16:10 | 0.10 | 04-MAR-05:00 | 5285.42 | 19-MAR-16:10 | 4125.33 | 19-MAR-14:00 | 1321.10 | 25-MAR-08:50 | 1414.72 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.764557E+10 | 0.196427E+10 | 720.00 | 0.517810E+10 | 0.246747E+10 | 0.00 | 0.69 | 01-APR-16:10 | 0.16 | 23-APR-04:00 | 4964.01 | 02-APR-16:10 | 3602.93 | 01-APR-15:30 | 1583.61 | 29-APR-16:15 | 1315.98 | 01-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.833605E+10 | 0.211719E+10 | 744.00 | 0.524794E+10 | 0.308811E+10 | 0.00 | 0.78 | 06-MAY-15:10 | 0.14 | 26-MAY-04:00 | 5535.91 | 06-MAY-15:10 | 4038.97 | 06-MAY-15:10 | 2068.60 | 22-MAY-10:10 | 1528.20 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.813344E+10 | 0.206150E+10 | 720.00 | 0.512855E+10 | 0.300489E+10 | 0.00 | 0.74 | 16-JUN-13:20 | 0.16 | 27-JUN-05:00 | 5371.38 | 16-JUN-15:20 | 3643.84 | 16-JUN-14:10 | 2074.09 | 15-JUN-10:20 | 1445.46 | 16-JUN-13:20 | 0.00 | 01-JUN-00:10 |
| July | 0.660121E+10 | 0.166199E+10 | 744.00 | 0.450448E+10 | 0.209672E+10 | 0.00 | 0.62 | 01-JUL-13:00 | 0.12 | 13-JUL-05:00 | 4418.05 | 01-JUL-13:00 | 3192.42 | 01-JUL-13:00 | 1436.88 | 05-JUL-10:40 | 1167.28 | 01-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.742534E+10 | 0.184450E+10 | 744.00 | 0.455696E+10 | 0.286838E+10 | 0.00 | 0.70 | 12-AUG-12:00 | 0.13 | 20-AUG-04:00 | 5162.71 | 12-AUG-12:00 | 3366.09 | 27-AUG-14:00 | 1973.06 | 05-AUG-09:20 | 1334.90 | 12-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 0.697278E+10 | 0.174587E+10 | 720.00 | 0.452149E+10 | 0.245129E+10 | 0.00 | 0.67 | 02-SEP-14:00 | 0.15 | 16-SEP-03:00 | 4935.60 | 25-SEP-14:00 | 3398.36 | 10-SEP-15:00 | 1786.23 | 25-SEP-12:00 | 1278.54 | 02-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.677617E+10 | 0.168172E+10 | 744.00 | 0.442322E+10 | 0.235295E+10 | 0.00 | 0.72 | 29-OCT-13:00 | 0.13 | 12-OCT-04:00 | 5306.42 | 29-OCT-13:00 | 3665.56 | 29-OCT-13:00 | 1716.63 | 29-OCT-15:20 | 1355.81 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.638392E+10 | 0.159570E+10 | 720.00 | 0.443200E+10 | 0.195192E+10 | 0.00 | 0.69 | 18-NOV-13:00 | 0.06 | 25-NOV-05:50 | 4793.08 | 18-NOV-13:00 | 3859.73 | 18-NOV-13:00 | 1635.52 | 10-NOV-13:30 | 1302.07 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.614291E+10 | 0.154464E+10 | 740.92 | 0.450961E+10 | 0.163330E+10 | 0.00 | 0.66 | 31-DEC-13:00 | 0.00 | 21-DEC-04:20 | 4656.05 | 31-DEC-13:00 | 3845.75 | 07-DEC-14:00 | 1257.36 | 09-DEC-15:10 | 1221.39 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.841404E+11 | 0.212605E+11 | 8755.58 | 0.571199E+11 | 0.270206E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.613077E+10 | 0.154464E+10 | 672.00 | 0.442322E+10 | 0.151823E+10 | 0.00 | 0.62 | 0.00 | 4418.05 | 3192.42 | 1128.63 | 1167.28 | 0.00 | |||||||
| Maximum of Months | 0.833605E+10 | 0.211719E+10 | 744.00 | 0.526529E+10 | 0.308811E+10 | 0.00 | 0.78 | 0.16 | 5535.91 | 4149.10 | 2074.09 | 1528.20 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.538232E+10 | 0.137288E+10 | 741.33 | 0.393276E+10 | 0.144956E+10 | 0.00 | 0.56 | 04-JAN-13:00 | 0.00 | 21-JAN-06:05 | 3884.35 | 04-JAN-13:00 | 3149.32 | 04-JAN-13:00 | 1072.34 | 11-JAN-17:10 | 1073.50 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.547176E+10 | 0.140840E+10 | 672.00 | 0.402040E+10 | 0.145137E+10 | 0.00 | 0.62 | 28-FEB-15:00 | 0.08 | 03-FEB-06:05 | 4308.71 | 28-FEB-15:00 | 3395.94 | 28-FEB-15:00 | 1150.45 | 14-FEB-19:30 | 1194.78 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.699337E+10 | 0.180080E+10 | 744.00 | 0.498852E+10 | 0.200485E+10 | 0.00 | 0.68 | 19-MAR-16:10 | 0.09 | 04-MAR-05:00 | 4874.38 | 19-MAR-16:10 | 3704.18 | 19-MAR-15:40 | 1267.65 | 27-MAR-08:40 | 1315.91 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.769161E+10 | 0.197615E+10 | 720.00 | 0.522424E+10 | 0.246738E+10 | 0.00 | 0.67 | 30-APR-16:10 | 0.16 | 23-APR-04:00 | 4884.98 | 30-APR-16:10 | 3498.96 | 11-APR-16:10 | 1562.77 | 29-APR-16:15 | 1274.33 | 11-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.862919E+10 | 0.218936E+10 | 744.00 | 0.550612E+10 | 0.312307E+10 | 0.00 | 0.81 | 06-MAY-15:10 | 0.14 | 26-MAY-04:00 | 5777.39 | 06-MAY-15:10 | 4257.55 | 06-MAY-15:00 | 2136.14 | 22-MAY-10:10 | 1589.53 | 06-MAY-15:00 | 0.00 | 01-MAY-00:10 |
| June | 0.865014E+10 | 0.218769E+10 | 720.00 | 0.558037E+10 | 0.306978E+10 | 0.00 | 0.80 | 16-JUN-13:20 | 0.16 | 27-JUN-05:00 | 5960.93 | 16-JUN-15:20 | 4102.93 | 13-JUN-15:10 | 2142.78 | 15-JUN-10:20 | 1567.80 | 16-JUN-13:20 | 0.00 | 01-JUN-00:10 |
| July | 0.689442E+10 | 0.173375E+10 | 744.00 | 0.476690E+10 | 0.212752E+10 | 0.00 | 0.64 | 01-JUL-13:00 | 0.13 | 13-JUL-05:00 | 4593.12 | 04-JUL-16:10 | 3368.79 | 04-JUL-15:10 | 1495.21 | 05-JUL-10:40 | 1208.31 | 01-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.759856E+10 | 0.188660E+10 | 744.00 | 0.470536E+10 | 0.289320E+10 | 0.00 | 0.71 | 01-AUG-15:10 | 0.13 | 20-AUG-04:00 | 5263.68 | 07-AUG-12:00 | 3537.59 | 01-AUG-15:10 | 1986.26 | 07-AUG-12:10 | 1362.59 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.688685E+10 | 0.172545E+10 | 720.00 | 0.445179E+10 | 0.243506E+10 | 0.00 | 0.66 | 02-SEP-14:00 | 0.14 | 16-SEP-03:00 | 4797.49 | 02-SEP-14:10 | 3312.28 | 10-SEP-15:00 | 1776.75 | 25-SEP-12:00 | 1261.17 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.643603E+10 | 0.159967E+10 | 744.00 | 0.413361E+10 | 0.230241E+10 | 0.00 | 0.64 | 29-OCT-13:00 | 0.13 | 12-OCT-04:00 | 4673.09 | 29-OCT-13:00 | 3125.76 | 29-OCT-13:00 | 1615.07 | 29-OCT-15:10 | 1206.54 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.574617E+10 | 0.144076E+10 | 720.00 | 0.387396E+10 | 0.187221E+10 | 0.00 | 0.59 | 10-NOV-13:20 | 0.06 | 25-NOV-05:50 | 4377.13 | 10-NOV-13:20 | 2935.71 | 18-NOV-13:00 | 1589.74 | 10-NOV-13:30 | 1118.02 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.522944E+10 | 0.132124E+10 | 739.67 | 0.369994E+10 | 0.152950E+10 | 0.00 | 0.53 | 09-DEC-14:00 | 0.00 | 15-DEC-06:05 | 3824.67 | 09-DEC-14:00 | 2799.84 | 07-DEC-14:00 | 1188.63 | 09-DEC-15:20 | 994.48 | 09-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.816099E+11 | 0.206427E+11 | 8753.00 | 0.548840E+11 | 0.267259E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.522944E+10 | 0.132124E+10 | 672.00 | 0.369994E+10 | 0.144956E+10 | 0.00 | 0.53 | 0.00 | 3824.67 | 2799.84 | 1072.34 | 994.48 | 0.00 | |||||||
| Maximum of Months | 0.865014E+10 | 0.218936E+10 | 744.00 | 0.558037E+10 | 0.312307E+10 | 0.00 | 0.81 | 0.16 | 5960.93 | 4257.55 | 2142.78 | 1589.53 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.459788E+10 | 0.117427E+10 | 743.17 | 0.334252E+10 | 0.125535E+10 | 0.00 | 0.49 | 04-JAN-13:00 | 0.00 | 23-JAN-06:05 | 3052.86 | 03-JAN-14:00 | 2449.88 | 04-JAN-13:00 | 863.96 | 11-JAN-11:00 | 850.36 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.459323E+10 | 0.118522E+10 | 672.00 | 0.335414E+10 | 0.123909E+10 | 0.00 | 0.54 | 28-FEB-15:00 | 0.09 | 24-FEB-07:00 | 3403.05 | 28-FEB-15:10 | 2688.22 | 28-FEB-15:00 | 928.55 | 14-FEB-19:40 | 954.29 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.577867E+10 | 0.149433E+10 | 744.00 | 0.411551E+10 | 0.166316E+10 | 0.00 | 0.60 | 19-MAR-16:10 | 0.11 | 04-MAR-05:00 | 3840.09 | 19-MAR-16:10 | 2954.23 | 19-MAR-16:10 | 969.04 | 28-MAR-19:40 | 1051.66 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.639268E+10 | 0.164972E+10 | 720.00 | 0.431826E+10 | 0.207442E+10 | 0.00 | 0.60 | 11-APR-16:10 | 0.17 | 23-APR-04:00 | 3967.95 | 30-APR-16:10 | 2887.94 | 11-APR-16:10 | 1249.46 | 29-APR-16:15 | 1054.17 | 11-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.726803E+10 | 0.185256E+10 | 744.00 | 0.463703E+10 | 0.263100E+10 | 0.00 | 0.72 | 06-MAY-15:10 | 0.16 | 26-MAY-04:00 | 4607.19 | 06-MAY-15:10 | 3431.51 | 06-MAY-15:10 | 1626.42 | 23-MAY-14:10 | 1286.01 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.728774E+10 | 0.185230E+10 | 720.00 | 0.470224E+10 | 0.258550E+10 | 0.00 | 0.72 | 13-JUN-15:10 | 0.18 | 27-JUN-05:00 | 4751.72 | 16-JUN-15:30 | 3385.67 | 13-JUN-15:10 | 1680.48 | 15-JUN-10:30 | 1294.54 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.592310E+10 | 0.149292E+10 | 744.00 | 0.408728E+10 | 0.183582E+10 | 0.00 | 0.59 | 04-JUL-16:10 | 0.14 | 13-JUL-05:00 | 3825.18 | 04-JUL-16:10 | 2849.78 | 14-JUL-16:30 | 1119.29 | 05-JUL-11:10 | 992.85 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.641286E+10 | 0.159884E+10 | 744.00 | 0.397728E+10 | 0.243558E+10 | 0.00 | 0.64 | 01-AUG-15:10 | 0.14 | 20-AUG-04:00 | 4225.70 | 01-AUG-15:10 | 2883.28 | 01-AUG-15:10 | 1535.39 | 12-AUG-12:00 | 1112.29 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.586916E+10 | 0.147351E+10 | 720.00 | 0.376689E+10 | 0.210227E+10 | 0.00 | 0.57 | 02-SEP-14:10 | 0.16 | 16-SEP-03:00 | 3788.21 | 25-SEP-14:00 | 2624.88 | 10-SEP-15:00 | 1378.07 | 25-SEP-12:00 | 1000.77 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.555288E+10 | 0.138196E+10 | 744.00 | 0.355162E+10 | 0.200126E+10 | 0.00 | 0.55 | 29-OCT-13:00 | 0.15 | 12-OCT-04:00 | 3627.98 | 29-OCT-13:00 | 2517.82 | 04-OCT-15:10 | 1223.85 | 29-OCT-15:20 | 949.76 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.497267E+10 | 0.124768E+10 | 720.00 | 0.333110E+10 | 0.164157E+10 | 0.00 | 0.52 | 10-NOV-13:30 | 0.07 | 25-NOV-06:05 | 3449.17 | 10-NOV-13:30 | 2365.54 | 18-NOV-13:00 | 1239.10 | 10-NOV-13:30 | 891.92 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.452534E+10 | 0.114351E+10 | 742.50 | 0.317799E+10 | 0.134736E+10 | 0.00 | 0.47 | 09-DEC-14:00 | 0.00 | 21-DEC-06:05 | 3056.23 | 09-DEC-14:00 | 2263.85 | 07-DEC-14:00 | 935.13 | 10-DEC-18:40 | 804.56 | 30-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.691742E+11 | 0.175468E+11 | 8757.67 | 0.463618E+11 | 0.228124E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.452534E+10 | 0.114351E+10 | 672.00 | 0.317799E+10 | 0.123909E+10 | 0.00 | 0.47 | 0.00 | 3052.86 | 2263.85 | 863.96 | 804.56 | 0.00 | |||||||
| Maximum of Months | 0.728774E+10 | 0.185256E+10 | 744.00 | 0.470224E+10 | 0.263100E+10 | 0.00 | 0.72 | 0.18 | 4751.72 | 3431.51 | 1680.48 | 1294.54 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.459868E+10 | 0.117435E+10 | 743.17 | 0.334278E+10 | 0.125591E+10 | 0.00 | 0.49 | 04-JAN-13:00 | 0.00 | 23-JAN-06:05 | 3054.98 | 03-JAN-14:00 | 2458.22 | 04-JAN-13:00 | 864.96 | 11-JAN-11:00 | 852.44 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.459450E+10 | 0.118540E+10 | 672.00 | 0.335486E+10 | 0.123964E+10 | 0.00 | 0.55 | 28-FEB-15:00 | 0.09 | 24-FEB-07:00 | 3397.98 | 28-FEB-15:10 | 2685.30 | 28-FEB-15:00 | 928.34 | 14-FEB-19:40 | 953.11 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.577825E+10 | 0.149408E+10 | 744.00 | 0.411484E+10 | 0.166341E+10 | 0.00 | 0.60 | 19-MAR-16:10 | 0.11 | 04-MAR-05:00 | 3826.33 | 19-MAR-16:10 | 2941.99 | 19-MAR-16:10 | 968.12 | 28-MAR-19:40 | 1047.96 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.639332E+10 | 0.164968E+10 | 720.00 | 0.431853E+10 | 0.207479E+10 | 0.00 | 0.60 | 30-APR-16:10 | 0.17 | 23-APR-04:00 | 3956.21 | 30-APR-16:10 | 2875.41 | 11-APR-16:10 | 1246.85 | 29-APR-16:15 | 1050.34 | 11-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.726933E+10 | 0.185260E+10 | 744.00 | 0.463782E+10 | 0.263150E+10 | 0.00 | 0.72 | 06-MAY-15:10 | 0.16 | 26-MAY-04:00 | 4599.53 | 06-MAY-15:10 | 3425.20 | 06-MAY-15:10 | 1625.33 | 23-MAY-14:10 | 1283.75 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.728937E+10 | 0.185241E+10 | 720.00 | 0.470333E+10 | 0.258604E+10 | 0.00 | 0.72 | 13-JUN-15:10 | 0.18 | 27-JUN-05:00 | 4742.63 | 16-JUN-15:30 | 3380.73 | 13-JUN-15:10 | 1682.60 | 15-JUN-10:30 | 1292.65 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.592436E+10 | 0.149303E+10 | 744.00 | 0.408794E+10 | 0.183641E+10 | 0.00 | 0.58 | 04-JUL-16:10 | 0.14 | 13-JUL-05:00 | 3811.52 | 04-JUL-16:10 | 2837.12 | 14-JUL-16:30 | 1121.18 | 05-JUL-11:10 | 989.36 | 04-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.641469E+10 | 0.159908E+10 | 744.00 | 0.397845E+10 | 0.243624E+10 | 0.00 | 0.64 | 01-AUG-15:10 | 0.14 | 20-AUG-04:00 | 4221.09 | 01-AUG-15:10 | 2880.21 | 01-AUG-15:10 | 1536.05 | 12-AUG-12:00 | 1110.94 | 01-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.587093E+10 | 0.147377E+10 | 720.00 | 0.376807E+10 | 0.210285E+10 | 0.00 | 0.58 | 02-SEP-14:10 | 0.16 | 16-SEP-03:00 | 3786.93 | 25-SEP-14:00 | 2624.15 | 06-SEP-14:10 | 1378.93 | 25-SEP-12:00 | 1001.55 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.555368E+10 | 0.138201E+10 | 744.00 | 0.355196E+10 | 0.200172E+10 | 0.00 | 0.55 | 29-OCT-13:00 | 0.15 | 12-OCT-04:00 | 3631.41 | 29-OCT-13:00 | 2511.01 | 04-OCT-15:10 | 1222.54 | 29-OCT-15:20 | 950.44 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.497361E+10 | 0.124778E+10 | 720.00 | 0.333154E+10 | 0.164208E+10 | 0.00 | 0.52 | 10-NOV-13:30 | 0.07 | 25-NOV-06:05 | 3452.94 | 10-NOV-13:30 | 2369.56 | 18-NOV-13:00 | 1239.17 | 10-NOV-13:30 | 892.71 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.452631E+10 | 0.114364E+10 | 742.50 | 0.317842E+10 | 0.134789E+10 | 0.00 | 0.47 | 09-DEC-14:00 | 0.00 | 21-DEC-06:05 | 3055.80 | 09-DEC-14:00 | 2265.04 | 07-DEC-14:00 | 934.59 | 10-DEC-18:40 | 804.55 | 30-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.691870E+11 | 0.175478E+11 | 8757.67 | 0.463685E+11 | 0.228185E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.452631E+10 | 0.114364E+10 | 672.00 | 0.317842E+10 | 0.123964E+10 | 0.00 | 0.47 | 0.00 | 3054.98 | 2265.04 | 864.96 | 804.55 | 0.00 | |||||||
| Maximum of Months | 0.728937E+10 | 0.185260E+10 | 744.00 | 0.470333E+10 | 0.263150E+10 | 0.00 | 0.72 | 0.18 | 4742.63 | 3425.20 | 1682.60 | 1292.65 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.551309E+10 | 0.140106E+10 | 743.67 | 0.415930E+10 | 0.135379E+10 | 0.00 | 0.65 | 04-JAN-13:00 | 0.00 | 23-JAN-06:05 | 4089.16 | 04-JAN-13:00 | 3454.38 | 04-JAN-13:00 | 925.42 | 11-JAN-11:00 | 1117.11 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.526138E+10 | 0.135198E+10 | 672.00 | 0.395309E+10 | 0.130829E+10 | 0.00 | 0.64 | 28-FEB-15:00 | 0.11 | 03-FEB-06:05 | 3998.64 | 28-FEB-15:00 | 3261.76 | 28-FEB-15:00 | 985.09 | 18-FEB-11:10 | 1107.95 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.609457E+10 | 0.157355E+10 | 744.00 | 0.439563E+10 | 0.169894E+10 | 0.00 | 0.67 | 19-MAR-16:10 | 0.11 | 04-MAR-05:00 | 4251.49 | 19-MAR-16:10 | 3355.62 | 19-MAR-15:30 | 997.32 | 25-MAR-09:00 | 1153.51 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.634490E+10 | 0.163740E+10 | 720.00 | 0.427198E+10 | 0.207292E+10 | 0.00 | 0.63 | 02-APR-16:10 | 0.17 | 23-APR-04:00 | 4085.76 | 02-APR-16:10 | 2957.41 | 01-APR-16:10 | 1270.15 | 29-APR-16:15 | 1089.64 | 01-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.697006E+10 | 0.177813E+10 | 744.00 | 0.437609E+10 | 0.259397E+10 | 0.00 | 0.69 | 06-MAY-15:10 | 0.16 | 26-MAY-04:00 | 4363.57 | 06-MAY-15:20 | 3211.83 | 06-MAY-15:10 | 1563.16 | 23-MAY-14:10 | 1223.05 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.676351E+10 | 0.172223E+10 | 720.00 | 0.424563E+10 | 0.251788E+10 | 0.00 | 0.65 | 13-JUN-15:10 | 0.18 | 27-JUN-05:00 | 4182.14 | 13-JUN-15:10 | 2910.29 | 13-JUN-15:10 | 1606.40 | 15-JUN-10:30 | 1159.17 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.562443E+10 | 0.141909E+10 | 744.00 | 0.382161E+10 | 0.180282E+10 | 0.00 | 0.54 | 04-JUL-16:10 | 0.14 | 13-JUL-05:00 | 3517.45 | 04-JUL-16:10 | 2586.70 | 15-JUL-16:02 | 1064.18 | 29-JUL-12:20 | 924.35 | 15-JUL-16:02 | 0.00 | 01-JUL-00:10 |
| August | 0.623682E+10 | 0.155551E+10 | 744.00 | 0.382738E+10 | 0.240943E+10 | 0.00 | 0.61 | 13-AUG-15:10 | 0.15 | 20-AUG-04:00 | 4071.20 | 12-AUG-12:00 | 2693.34 | 13-AUG-15:10 | 1542.56 | 12-AUG-12:00 | 1068.98 | 13-AUG-14:10 | 0.00 | 01-AUG-00:10 |
| September | 0.595520E+10 | 0.149439E+10 | 720.00 | 0.383738E+10 | 0.211782E+10 | 0.00 | 0.60 | 30-SEP-14:00 | 0.16 | 16-SEP-03:00 | 3939.34 | 25-SEP-14:00 | 2804.84 | 30-SEP-14:00 | 1385.75 | 25-SEP-12:00 | 1039.28 | 30-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.589703E+10 | 0.146606E+10 | 744.00 | 0.384482E+10 | 0.205221E+10 | 0.00 | 0.65 | 29-OCT-13:00 | 0.15 | 12-OCT-04:00 | 4258.06 | 29-OCT-13:00 | 3075.11 | 28-OCT-13:00 | 1316.29 | 29-OCT-15:30 | 1102.57 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.561950E+10 | 0.140638E+10 | 720.00 | 0.389606E+10 | 0.172344E+10 | 0.00 | 0.65 | 18-NOV-13:00 | 0.08 | 25-NOV-06:05 | 4108.71 | 18-NOV-13:00 | 3293.17 | 18-NOV-13:00 | 1279.22 | 10-NOV-13:30 | 1121.57 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.545187E+10 | 0.137208E+10 | 742.97 | 0.399786E+10 | 0.145402E+10 | 0.00 | 0.61 | 31-DEC-13:20 | 0.00 | 21-DEC-06:05 | 3922.19 | 31-DEC-13:00 | 3318.32 | 07-DEC-14:00 | 1027.44 | 10-DEC-09:20 | 1035.22 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.717324E+11 | 0.181778E+11 | 8758.64 | 0.486268E+11 | 0.231055E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.526138E+10 | 0.135198E+10 | 672.00 | 0.382161E+10 | 0.130829E+10 | 0.00 | 0.54 | 0.00 | 3517.45 | 2586.70 | 925.42 | 924.35 | 0.00 | |||||||
| Maximum of Months | 0.697006E+10 | 0.177813E+10 | 744.00 | 0.439563E+10 | 0.259397E+10 | 0.00 | 0.69 | 0.18 | 4363.57 | 3454.38 | 1606.40 | 1223.05 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.551373E+10 | 0.140101E+10 | 743.67 | 0.415940E+10 | 0.135433E+10 | 0.00 | 0.66 | 04-JAN-13:00 | 0.00 | 23-JAN-06:05 | 4097.13 | 04-JAN-13:00 | 3462.24 | 04-JAN-13:00 | 926.30 | 11-JAN-11:00 | 1118.83 | 04-JAN-13:00 | 0.00 | 01-JAN-00:10 |
| February | 0.526252E+10 | 0.135205E+10 | 672.00 | 0.395370E+10 | 0.130882E+10 | 0.00 | 0.64 | 28-FEB-15:00 | 0.11 | 03-FEB-06:05 | 3994.55 | 28-FEB-15:00 | 3258.38 | 28-FEB-15:00 | 986.14 | 18-FEB-11:10 | 1106.66 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.609416E+10 | 0.157327E+10 | 744.00 | 0.439493E+10 | 0.169923E+10 | 0.00 | 0.67 | 19-MAR-16:10 | 0.11 | 04-MAR-05:00 | 4237.64 | 19-MAR-16:10 | 3346.37 | 19-MAR-15:20 | 1001.10 | 25-MAR-09:00 | 1149.80 | 19-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.634558E+10 | 0.163737E+10 | 720.00 | 0.427225E+10 | 0.207334E+10 | 0.00 | 0.63 | 02-APR-16:10 | 0.17 | 23-APR-04:00 | 4070.68 | 02-APR-16:10 | 2946.40 | 01-APR-16:10 | 1267.42 | 29-APR-16:15 | 1086.25 | 01-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.697144E+10 | 0.177822E+10 | 744.00 | 0.437690E+10 | 0.259454E+10 | 0.00 | 0.69 | 06-MAY-15:10 | 0.16 | 26-MAY-04:00 | 4354.72 | 06-MAY-15:20 | 3205.65 | 06-MAY-15:10 | 1562.01 | 23-MAY-14:10 | 1220.82 | 06-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.676525E+10 | 0.172242E+10 | 720.00 | 0.424676E+10 | 0.251849E+10 | 0.00 | 0.65 | 13-JUN-15:10 | 0.18 | 27-JUN-05:00 | 4175.93 | 13-JUN-15:10 | 2905.61 | 13-JUN-15:10 | 1608.96 | 15-JUN-10:30 | 1157.33 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.562576E+10 | 0.141924E+10 | 744.00 | 0.382230E+10 | 0.180346E+10 | 0.00 | 0.54 | 04-JUL-16:10 | 0.14 | 13-JUL-05:00 | 3503.63 | 04-JUL-16:10 | 2582.23 | 15-JUL-16:02 | 1066.19 | 05-JUL-11:10 | 922.88 | 15-JUL-16:02 | 0.00 | 01-JUL-00:10 |
| August | 0.623870E+10 | 0.155578E+10 | 744.00 | 0.382856E+10 | 0.241015E+10 | 0.00 | 0.61 | 13-AUG-15:10 | 0.15 | 20-AUG-04:00 | 4075.60 | 12-AUG-12:00 | 2688.89 | 13-AUG-15:10 | 1543.26 | 12-AUG-12:00 | 1068.85 | 13-AUG-14:10 | 0.00 | 01-AUG-00:10 |
| September | 0.595698E+10 | 0.149464E+10 | 720.00 | 0.383854E+10 | 0.211844E+10 | 0.00 | 0.60 | 30-SEP-14:00 | 0.16 | 16-SEP-03:00 | 3938.08 | 25-SEP-14:00 | 2801.78 | 30-SEP-14:00 | 1386.59 | 25-SEP-12:00 | 1038.07 | 30-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.589782E+10 | 0.146607E+10 | 744.00 | 0.384512E+10 | 0.205270E+10 | 0.00 | 0.65 | 29-OCT-13:00 | 0.15 | 12-OCT-04:00 | 4261.26 | 29-OCT-13:00 | 3079.55 | 28-OCT-13:00 | 1314.97 | 29-OCT-15:30 | 1103.09 | 29-OCT-13:00 | 0.00 | 01-OCT-00:10 |
| November | 0.562034E+10 | 0.140639E+10 | 720.00 | 0.389640E+10 | 0.172394E+10 | 0.00 | 0.65 | 18-NOV-13:00 | 0.08 | 25-NOV-06:05 | 4112.09 | 18-NOV-13:00 | 3296.85 | 18-NOV-13:00 | 1279.31 | 10-NOV-13:30 | 1122.16 | 18-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.545266E+10 | 0.137208E+10 | 742.97 | 0.399813E+10 | 0.145453E+10 | 0.00 | 0.62 | 31-DEC-13:00 | 0.00 | 21-DEC-06:05 | 3929.70 | 31-DEC-13:00 | 3318.84 | 07-DEC-14:00 | 1029.79 | 10-DEC-09:20 | 1036.84 | 31-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.717449E+11 | 0.181785E+11 | 8758.64 | 0.486330E+11 | 0.231120E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.526252E+10 | 0.135205E+10 | 672.00 | 0.382230E+10 | 0.130882E+10 | 0.00 | 0.54 | 0.00 | 3503.63 | 2582.23 | 926.30 | 922.88 | 0.00 | |||||||
| Maximum of Months | 0.697144E+10 | 0.177822E+10 | 744.00 | 0.439493E+10 | 0.259454E+10 | 0.00 | 0.69 | 0.18 | 4354.72 | 3462.24 | 1608.96 | 1220.82 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 279.50 | 18.87 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 258.19 | 13.35 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 192.29 | 7.37 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 155.60 | 1.89 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 157.75 | 3.38 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 155.28 | 3.57 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 139.15 | 8.04 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 134.43 | 5.68 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 152.36 | 5.94 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 183.30 | 8.54 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 235.06 | 12.25 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 276.19 | 22.54 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 192.93 | 9.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 134.43 | 1.89 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 279.50 | 22.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.93 | 24.34 | 44.59 | 135.84 | 13.22 | 0.00 | 0.00 | 0.00 |
| February | 75.52 | 26.73 | 48.79 | 152.63 | 9.37 | 0.00 | 0.00 | 0.00 |
| March | 84.70 | 33.48 | 51.21 | 174.58 | 5.36 | 0.00 | 0.00 | 0.00 |
| April | 84.95 | 32.47 | 52.48 | 180.41 | 1.28 | 0.00 | 0.00 | 0.00 |
| May | 72.37 | 21.44 | 50.93 | 160.93 | 2.19 | 0.00 | 0.00 | 0.00 |
| June | 78.39 | 26.99 | 51.39 | 170.70 | 2.32 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 15.79 | 51.11 | 137.98 | 5.23 | 0.00 | 0.00 | 0.00 |
| August | 72.77 | 21.58 | 51.19 | 146.10 | 3.68 | 0.00 | 0.00 | 0.00 |
| September | 68.03 | 18.82 | 49.21 | 140.84 | 3.84 | 0.00 | 0.00 | 0.00 |
| October | 63.95 | 16.48 | 47.47 | 126.33 | 5.55 | 0.00 | 0.00 | 0.00 |
| November | 62.28 | 16.92 | 45.35 | 123.29 | 8.10 | 0.00 | 0.00 | 0.00 |
| December | 63.86 | 20.91 | 42.95 | 125.37 | 15.40 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.84 | 22.96 | 48.88 | 147.81 | 6.30 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.28 | 15.79 | 42.95 | 123.29 | 1.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.95 | 33.48 | 52.48 | 180.41 | 15.40 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.93 | 24.34 | 44.59 | 137.39 | 12.46 | 0.00 | 0.00 | 0.00 |
| February | 75.52 | 26.73 | 48.79 | 153.97 | 8.81 | 0.00 | 0.00 | 0.00 |
| March | 84.70 | 33.48 | 51.21 | 175.20 | 5.15 | 0.00 | 0.00 | 0.00 |
| April | 84.95 | 32.47 | 52.48 | 180.26 | 1.29 | 0.00 | 0.00 | 0.00 |
| May | 72.37 | 21.44 | 50.93 | 160.27 | 2.29 | 0.00 | 0.00 | 0.00 |
| June | 78.39 | 26.99 | 51.39 | 169.49 | 2.47 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 15.79 | 51.11 | 137.37 | 5.45 | 0.00 | 0.00 | 0.00 |
| August | 72.77 | 21.58 | 51.19 | 145.74 | 3.78 | 0.00 | 0.00 | 0.00 |
| September | 68.03 | 18.82 | 49.21 | 140.99 | 3.82 | 0.00 | 0.00 | 0.00 |
| October | 63.95 | 16.48 | 47.47 | 126.96 | 5.33 | 0.00 | 0.00 | 0.00 |
| November | 62.28 | 16.92 | 45.35 | 124.50 | 7.64 | 0.00 | 0.00 | 0.00 |
| December | 63.86 | 20.91 | 42.95 | 126.93 | 14.63 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.84 | 22.96 | 48.88 | 148.15 | 6.10 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.28 | 15.79 | 42.95 | 124.50 | 1.29 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.95 | 33.48 | 52.48 | 180.26 | 14.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 113.86 | 19.06 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 127.38 | 13.61 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 137.76 | 7.91 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 158.99 | 1.99 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 201.42 | 3.61 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 236.11 | 3.85 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 186.54 | 8.48 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 155.51 | 6.13 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 136.89 | 5.93 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 122.57 | 8.13 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 116.66 | 11.64 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 109.25 | 22.29 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 150.30 | 9.39 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 109.25 | 1.99 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 236.11 | 22.29 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 259.70 | 45.25 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 238.28 | 39.11 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 173.29 | 32.21 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 128.18 | 21.68 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 129.47 | 22.20 | 0.33 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 129.17 | 23.39 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 117.31 | 31.85 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 114.81 | 29.25 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 130.82 | 29.51 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 163.55 | 34.21 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 215.36 | 37.06 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 258.04 | 47.91 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 171.18 | 32.81 | 0.33 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 114.81 | 21.68 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 259.70 | 47.91 | 0.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.01 | 23.03 | 44.99 | 120.02 | 29.64 | 0.00 | 0.00 | 0.00 |
| February | 76.73 | 28.00 | 48.73 | 140.65 | 25.38 | 0.00 | 0.00 | 0.00 |
| March | 83.94 | 32.81 | 51.13 | 159.57 | 20.57 | 0.00 | 0.00 | 0.00 |
| April | 84.79 | 32.41 | 52.39 | 163.00 | 13.90 | 0.00 | 0.00 | 0.00 |
| May | 72.85 | 22.03 | 50.82 | 143.91 | 14.25 | 0.33 | 0.00 | 0.00 |
| June | 77.64 | 25.59 | 52.06 | 153.03 | 15.09 | 0.00 | 0.00 | 0.00 |
| July | 66.34 | 14.90 | 51.45 | 122.18 | 20.21 | 0.00 | 0.00 | 0.00 |
| August | 72.93 | 21.41 | 51.52 | 134.15 | 18.72 | 0.00 | 0.00 | 0.00 |
| September | 68.57 | 18.71 | 49.85 | 128.03 | 18.80 | 0.00 | 0.00 | 0.00 |
| October | 64.32 | 16.51 | 47.81 | 114.25 | 22.25 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 17.27 | 45.03 | 110.57 | 24.35 | 0.00 | 0.00 | 0.00 |
| December | 63.64 | 20.44 | 43.20 | 111.94 | 31.47 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.78 | 22.71 | 49.08 | 133.32 | 21.22 | 0.33 | 0.00 | 0.00 |
| Minimum of Months | 62.31 | 14.90 | 43.20 | 110.57 | 13.90 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.79 | 32.81 | 52.39 | 163.00 | 31.47 | 0.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.01 | 23.03 | 44.99 | 134.70 | 11.51 | 0.00 | 0.00 | 0.00 |
| February | 76.73 | 28.00 | 48.73 | 155.55 | 8.02 | 0.00 | 0.00 | 0.00 |
| March | 83.94 | 32.81 | 51.13 | 173.64 | 4.43 | 0.00 | 0.00 | 0.00 |
| April | 84.79 | 32.41 | 52.39 | 181.67 | 1.20 | 0.00 | 0.00 | 0.00 |
| May | 72.85 | 22.03 | 50.82 | 162.31 | 2.33 | 0.00 | 0.00 | 0.00 |
| June | 77.64 | 25.59 | 52.06 | 169.07 | 2.49 | 0.00 | 0.00 | 0.00 |
| July | 66.34 | 14.90 | 51.45 | 136.60 | 5.48 | 0.00 | 0.00 | 0.00 |
| August | 72.93 | 21.41 | 51.52 | 146.99 | 3.93 | 0.00 | 0.00 | 0.00 |
| September | 68.57 | 18.71 | 49.85 | 142.93 | 3.81 | 0.00 | 0.00 | 0.00 |
| October | 64.32 | 16.51 | 47.81 | 128.18 | 5.25 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 17.27 | 45.03 | 124.71 | 7.45 | 0.00 | 0.00 | 0.00 |
| December | 63.64 | 20.44 | 43.20 | 125.36 | 13.83 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.78 | 22.71 | 49.08 | 148.35 | 5.82 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.31 | 14.90 | 43.20 | 124.71 | 1.20 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.79 | 32.81 | 52.39 | 181.67 | 13.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 113.70 | 18.89 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 127.19 | 13.47 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 137.68 | 7.74 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 158.93 | 1.94 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 201.30 | 3.57 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 235.98 | 3.81 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 186.39 | 8.40 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 155.33 | 6.06 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 136.72 | 5.88 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 122.47 | 8.05 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 116.54 | 11.57 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 109.10 | 22.15 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 150.17 | 9.30 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 109.10 | 1.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 235.98 | 22.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 115.72 | 18.19 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 129.59 | 12.67 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 140.51 | 7.07 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 162.46 | 1.71 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 204.43 | 3.21 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 239.24 | 3.43 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 188.79 | 7.68 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 158.04 | 5.48 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 139.40 | 5.24 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 124.58 | 7.38 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 118.58 | 10.90 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 110.99 | 21.47 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 152.75 | 8.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 110.99 | 1.71 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 239.24 | 21.47 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 115.72 | 18.19 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 129.59 | 12.66 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 140.51 | 7.07 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 162.46 | 1.71 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 204.42 | 3.21 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 239.23 | 3.43 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 188.79 | 7.68 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 158.03 | 5.48 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 139.40 | 5.24 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 124.58 | 7.38 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 118.58 | 10.89 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 110.98 | 21.47 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 152.75 | 8.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 110.98 | 1.71 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 239.23 | 21.47 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 281.17 | 18.14 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 260.27 | 12.55 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 195.05 | 6.65 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 159.15 | 1.66 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 160.86 | 3.00 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 158.65 | 3.17 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 141.46 | 7.25 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 137.05 | 5.06 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 154.84 | 5.29 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 185.20 | 7.86 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 236.81 | 11.61 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 277.72 | 21.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 195.36 | 8.68 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 137.05 | 1.66 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 281.17 | 21.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 280.17 | 18.97 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 259.21 | 13.33 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 193.85 | 7.26 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 157.46 | 1.88 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 159.28 | 3.34 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 157.12 | 3.52 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 140.28 | 7.94 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 135.77 | 5.61 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 153.58 | 5.87 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 184.10 | 8.64 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 235.78 | 12.38 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 276.82 | 22.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 194.12 | 9.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 135.77 | 1.88 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 280.17 | 22.65 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 280.43 | 17.20 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 259.54 | 11.64 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 194.38 | 6.05 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 158.99 | 1.48 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 161.07 | 2.66 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 158.93 | 2.85 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 141.43 | 6.56 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 137.22 | 4.42 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 154.78 | 4.69 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 184.74 | 7.13 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 236.30 | 10.73 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 277.10 | 20.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 195.08 | 8.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 137.22 | 1.48 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 280.43 | 20.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.93 | 24.34 | 44.59 | 136.58 | 12.10 | 0.00 | 0.00 | 0.00 |
| February | 75.52 | 26.73 | 48.79 | 153.50 | 8.22 | 0.00 | 0.00 | 0.00 |
| March | 84.70 | 33.48 | 51.21 | 175.60 | 4.51 | 0.00 | 0.00 | 0.00 |
| April | 84.95 | 32.47 | 52.48 | 182.07 | 1.00 | 0.00 | 0.00 | 0.00 |
| May | 72.37 | 21.44 | 50.93 | 162.75 | 1.72 | 0.00 | 0.00 | 0.00 |
| June | 78.39 | 26.99 | 51.39 | 172.69 | 1.86 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 15.79 | 51.11 | 139.20 | 4.27 | 0.00 | 0.00 | 0.00 |
| August | 72.77 | 21.58 | 51.19 | 147.60 | 2.88 | 0.00 | 0.00 | 0.00 |
| September | 68.03 | 18.82 | 49.21 | 142.24 | 3.04 | 0.00 | 0.00 | 0.00 |
| October | 63.95 | 16.48 | 47.47 | 127.26 | 4.61 | 0.00 | 0.00 | 0.00 |
| November | 62.28 | 16.92 | 45.35 | 124.20 | 7.07 | 0.00 | 0.00 | 0.00 |
| December | 63.86 | 20.91 | 42.95 | 126.13 | 14.24 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.84 | 22.96 | 48.88 | 149.05 | 5.46 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.28 | 15.79 | 42.95 | 124.20 | 1.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.95 | 33.48 | 52.48 | 182.07 | 14.24 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.93 | 24.34 | 44.59 | 138.06 | 11.55 | 0.00 | 0.00 | 0.00 |
| February | 75.52 | 26.73 | 48.79 | 154.77 | 7.83 | 0.00 | 0.00 | 0.00 |
| March | 84.70 | 33.48 | 51.21 | 176.18 | 4.36 | 0.00 | 0.00 | 0.00 |
| April | 84.95 | 32.47 | 52.48 | 181.98 | 1.00 | 0.00 | 0.00 | 0.00 |
| May | 72.37 | 21.44 | 50.93 | 162.19 | 1.78 | 0.00 | 0.00 | 0.00 |
| June | 78.39 | 26.99 | 51.39 | 171.65 | 1.95 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 15.79 | 51.11 | 138.68 | 4.42 | 0.00 | 0.00 | 0.00 |
| August | 72.77 | 21.58 | 51.19 | 147.30 | 2.93 | 0.00 | 0.00 | 0.00 |
| September | 68.03 | 18.82 | 49.21 | 142.41 | 3.01 | 0.00 | 0.00 | 0.00 |
| October | 63.95 | 16.48 | 47.47 | 127.86 | 4.44 | 0.00 | 0.00 | 0.00 |
| November | 62.28 | 16.92 | 45.35 | 125.35 | 6.72 | 0.00 | 0.00 | 0.00 |
| December | 63.86 | 20.91 | 42.95 | 127.61 | 13.67 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.84 | 22.96 | 48.88 | 149.39 | 5.31 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.28 | 15.79 | 42.95 | 125.35 | 1.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.95 | 33.48 | 52.48 | 181.98 | 13.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 115.27 | 17.61 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 129.04 | 12.08 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 139.82 | 6.68 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 162.02 | 1.53 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 204.33 | 2.84 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 239.13 | 3.04 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 188.54 | 6.94 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 158.06 | 4.87 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 139.36 | 4.67 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 124.28 | 6.74 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 118.27 | 10.19 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 110.67 | 20.76 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 152.46 | 8.17 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 110.67 | 1.53 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 239.13 | 20.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 280.28 | 17.03 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 259.38 | 11.50 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 194.34 | 5.91 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 158.96 | 1.46 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 160.96 | 2.62 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 158.81 | 2.82 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 141.30 | 6.48 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 137.04 | 4.36 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 154.63 | 4.63 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 184.63 | 7.04 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 236.19 | 10.65 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 276.95 | 20.70 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 194.96 | 7.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 137.04 | 1.46 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 280.28 | 20.70 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.01 | 23.03 | 44.99 | 133.93 | 11.12 | 0.00 | 0.00 | 0.00 |
| February | 76.73 | 28.00 | 48.73 | 155.21 | 7.42 | 0.00 | 0.00 | 0.00 |
| March | 83.94 | 32.81 | 51.13 | 174.19 | 3.78 | 0.00 | 0.00 | 0.00 |
| April | 84.79 | 32.41 | 52.39 | 183.67 | 0.94 | 0.00 | 0.00 | 0.00 |
| May | 72.85 | 22.03 | 50.82 | 164.82 | 1.77 | 0.00 | 0.00 | 0.00 |
| June | 77.64 | 25.59 | 52.06 | 172.16 | 1.87 | 0.00 | 0.00 | 0.00 |
| July | 66.34 | 14.90 | 51.45 | 138.47 | 4.34 | 0.00 | 0.00 | 0.00 |
| August | 72.93 | 21.41 | 51.52 | 148.85 | 3.06 | 0.00 | 0.00 | 0.00 |
| September | 68.57 | 18.71 | 49.85 | 144.24 | 3.02 | 0.00 | 0.00 | 0.00 |
| October | 64.32 | 16.51 | 47.81 | 128.52 | 4.55 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 17.27 | 45.03 | 124.43 | 6.89 | 0.00 | 0.00 | 0.00 |
| December | 63.64 | 20.44 | 43.20 | 124.58 | 13.44 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.78 | 22.71 | 49.08 | 149.30 | 5.19 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.31 | 14.90 | 43.20 | 124.43 | 0.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.79 | 32.81 | 52.39 | 183.67 | 13.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.01 | 23.03 | 44.99 | 135.49 | 10.61 | 0.00 | 0.00 | 0.00 |
| February | 76.73 | 28.00 | 48.73 | 156.54 | 7.07 | 0.00 | 0.00 | 0.00 |
| March | 83.94 | 32.81 | 51.13 | 174.80 | 3.64 | 0.00 | 0.00 | 0.00 |
| April | 84.79 | 32.41 | 52.39 | 183.57 | 0.94 | 0.00 | 0.00 | 0.00 |
| May | 72.85 | 22.03 | 50.82 | 164.26 | 1.84 | 0.00 | 0.00 | 0.00 |
| June | 77.64 | 25.59 | 52.06 | 171.15 | 1.97 | 0.00 | 0.00 | 0.00 |
| July | 66.34 | 14.90 | 51.45 | 137.96 | 4.48 | 0.00 | 0.00 | 0.00 |
| August | 72.93 | 21.41 | 51.52 | 148.56 | 3.11 | 0.00 | 0.00 | 0.00 |
| September | 68.57 | 18.71 | 49.85 | 144.40 | 3.00 | 0.00 | 0.00 | 0.00 |
| October | 64.32 | 16.51 | 47.81 | 129.14 | 4.38 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 17.27 | 45.03 | 125.59 | 6.55 | 0.00 | 0.00 | 0.00 |
| December | 63.64 | 20.44 | 43.20 | 126.12 | 12.90 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.78 | 22.71 | 49.08 | 149.67 | 5.05 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.31 | 14.90 | 43.20 | 125.59 | 0.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.79 | 32.81 | 52.39 | 183.57 | 12.90 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 115.11 | 17.45 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 128.86 | 11.95 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 139.76 | 6.54 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 161.98 | 1.49 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 204.23 | 2.80 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 239.01 | 3.01 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 188.40 | 6.85 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 157.88 | 4.80 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 139.20 | 4.61 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 124.17 | 6.66 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 118.15 | 10.11 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 110.52 | 20.62 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 152.33 | 8.08 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 110.52 | 1.49 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 239.01 | 20.62 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 116.96 | 17.03 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 131.09 | 11.46 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 142.38 | 6.12 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 165.11 | 1.37 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 206.91 | 2.59 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 241.76 | 2.79 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 190.42 | 6.46 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 160.17 | 4.50 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 141.48 | 4.28 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 126.06 | 6.27 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 119.96 | 9.73 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 112.20 | 20.26 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 154.60 | 7.74 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 112.20 | 1.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 241.76 | 20.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 116.96 | 17.03 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 131.08 | 11.46 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 142.38 | 6.11 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 165.10 | 1.37 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 206.91 | 2.59 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 241.76 | 2.79 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 190.41 | 6.46 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 160.16 | 4.50 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 141.47 | 4.28 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 126.05 | 6.26 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 119.95 | 9.72 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 112.19 | 20.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 154.59 | 7.74 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 112.19 | 1.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 241.76 | 20.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 281.99 | 16.69 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 261.51 | 11.10 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 196.96 | 5.52 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 162.20 | 1.35 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 163.80 | 2.42 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 161.82 | 2.60 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 143.40 | 6.07 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 139.45 | 4.06 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 156.91 | 4.31 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 186.45 | 6.67 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 237.87 | 10.31 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 278.48 | 20.40 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 197.24 | 7.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 139.45 | 1.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 281.99 | 20.40 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 281.99 | 16.69 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 261.50 | 11.10 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 196.96 | 5.52 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 162.19 | 1.35 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 163.80 | 2.42 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 161.82 | 2.60 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 143.39 | 6.07 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 139.44 | 4.06 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 156.90 | 4.30 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 186.45 | 6.67 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 237.87 | 10.31 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 278.47 | 20.39 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 197.24 | 7.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 139.44 | 1.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 281.99 | 20.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 275.31 | 16.71 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 254.04 | 11.06 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 188.65 | 5.75 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 153.06 | 1.41 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 155.44 | 2.68 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 153.10 | 2.90 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 136.54 | 6.57 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 132.39 | 4.35 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 149.65 | 4.73 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 180.01 | 7.12 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 231.38 | 10.44 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 272.31 | 20.31 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 189.83 | 7.84 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 132.39 | 1.41 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 275.31 | 20.31 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.93 | 24.34 | 44.59 | 133.17 | 11.73 | 0.00 | 0.00 | 0.00 |
| February | 75.52 | 26.73 | 48.79 | 149.82 | 7.82 | 0.00 | 0.00 | 0.00 |
| March | 84.70 | 33.48 | 51.21 | 171.81 | 4.36 | 0.00 | 0.00 | 0.00 |
| April | 84.95 | 32.47 | 52.48 | 178.03 | 0.95 | 0.00 | 0.00 | 0.00 |
| May | 72.37 | 21.44 | 50.93 | 158.85 | 1.73 | 0.00 | 0.00 | 0.00 |
| June | 78.39 | 26.99 | 51.39 | 168.63 | 1.88 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 15.79 | 51.11 | 135.77 | 4.26 | 0.00 | 0.00 | 0.00 |
| August | 72.77 | 21.58 | 51.19 | 144.19 | 2.81 | 0.00 | 0.00 | 0.00 |
| September | 68.03 | 18.82 | 49.21 | 138.69 | 3.04 | 0.00 | 0.00 | 0.00 |
| October | 63.95 | 16.48 | 47.47 | 124.11 | 4.58 | 0.00 | 0.00 | 0.00 |
| November | 62.28 | 16.92 | 45.35 | 120.91 | 6.82 | 0.00 | 0.00 | 0.00 |
| December | 63.86 | 20.91 | 42.95 | 122.90 | 13.80 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.84 | 22.96 | 48.88 | 145.47 | 5.32 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.28 | 15.79 | 42.95 | 120.91 | 0.95 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.95 | 33.48 | 52.48 | 178.03 | 13.80 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.93 | 24.34 | 44.59 | 135.24 | 11.27 | 0.00 | 0.00 | 0.00 |
| February | 75.52 | 26.73 | 48.79 | 151.56 | 7.53 | 0.00 | 0.00 | 0.00 |
| March | 84.70 | 33.48 | 51.21 | 172.57 | 4.25 | 0.00 | 0.00 | 0.00 |
| April | 84.95 | 32.47 | 52.48 | 177.89 | 0.95 | 0.00 | 0.00 | 0.00 |
| May | 72.37 | 21.44 | 50.93 | 158.12 | 1.77 | 0.00 | 0.00 | 0.00 |
| June | 78.39 | 26.99 | 51.39 | 167.29 | 1.95 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 15.79 | 51.11 | 135.06 | 4.38 | 0.00 | 0.00 | 0.00 |
| August | 72.77 | 21.58 | 51.19 | 143.78 | 2.86 | 0.00 | 0.00 | 0.00 |
| September | 68.03 | 18.82 | 49.21 | 138.90 | 3.02 | 0.00 | 0.00 | 0.00 |
| October | 63.95 | 16.48 | 47.47 | 124.92 | 4.45 | 0.00 | 0.00 | 0.00 |
| November | 62.28 | 16.92 | 45.35 | 122.49 | 6.57 | 0.00 | 0.00 | 0.00 |
| December | 63.86 | 20.91 | 42.95 | 124.98 | 13.31 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.84 | 22.96 | 48.88 | 145.96 | 5.20 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.28 | 15.79 | 42.95 | 122.49 | 0.95 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.95 | 33.48 | 52.48 | 177.89 | 13.31 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 111.15 | 17.23 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 124.41 | 11.70 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 134.57 | 6.54 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 156.03 | 1.46 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 198.40 | 2.84 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 232.88 | 3.07 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 183.29 | 6.93 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 153.17 | 4.82 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 134.40 | 4.72 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 120.04 | 6.77 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 114.09 | 9.99 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 106.84 | 20.26 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 147.50 | 8.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 106.84 | 1.46 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 232.88 | 20.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 275.06 | 16.43 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 253.80 | 10.87 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 188.61 | 5.56 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 153.06 | 1.38 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 155.30 | 2.63 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 152.91 | 2.84 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 136.33 | 6.44 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 132.11 | 4.24 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 149.42 | 4.63 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 179.84 | 6.99 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 231.22 | 10.31 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 272.05 | 20.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 189.65 | 7.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 132.11 | 1.38 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 275.06 | 20.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.01 | 23.03 | 44.99 | 130.45 | 10.72 | 0.00 | 0.00 | 0.00 |
| February | 76.73 | 28.00 | 48.73 | 151.45 | 6.99 | 0.00 | 0.00 | 0.00 |
| March | 83.94 | 32.81 | 51.13 | 170.17 | 3.55 | 0.00 | 0.00 | 0.00 |
| April | 84.79 | 32.41 | 52.39 | 179.52 | 0.88 | 0.00 | 0.00 | 0.00 |
| May | 72.85 | 22.03 | 50.82 | 160.93 | 1.78 | 0.00 | 0.00 | 0.00 |
| June | 77.64 | 25.59 | 52.06 | 168.17 | 1.89 | 0.00 | 0.00 | 0.00 |
| July | 66.34 | 14.90 | 51.45 | 135.17 | 4.33 | 0.00 | 0.00 | 0.00 |
| August | 72.93 | 21.41 | 51.52 | 145.57 | 3.00 | 0.00 | 0.00 | 0.00 |
| September | 68.57 | 18.71 | 49.85 | 140.78 | 3.02 | 0.00 | 0.00 | 0.00 |
| October | 64.32 | 16.51 | 47.81 | 125.35 | 4.49 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 17.27 | 45.03 | 121.12 | 6.66 | 0.00 | 0.00 | 0.00 |
| December | 63.64 | 20.44 | 43.20 | 121.33 | 13.01 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.78 | 22.71 | 49.08 | 145.72 | 5.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.31 | 14.90 | 43.20 | 121.12 | 0.88 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.79 | 32.81 | 52.39 | 179.52 | 13.01 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 68.01 | 23.03 | 44.99 | 132.60 | 10.31 | 0.00 | 0.00 | 0.00 |
| February | 76.73 | 28.00 | 48.73 | 153.26 | 6.73 | 0.00 | 0.00 | 0.00 |
| March | 83.94 | 32.81 | 51.13 | 170.98 | 3.44 | 0.00 | 0.00 | 0.00 |
| April | 84.79 | 32.41 | 52.39 | 179.38 | 0.88 | 0.00 | 0.00 | 0.00 |
| May | 72.85 | 22.03 | 50.82 | 160.20 | 1.83 | 0.00 | 0.00 | 0.00 |
| June | 77.64 | 25.59 | 52.06 | 166.87 | 1.97 | 0.00 | 0.00 | 0.00 |
| July | 66.34 | 14.90 | 51.45 | 134.47 | 4.44 | 0.00 | 0.00 | 0.00 |
| August | 72.93 | 21.41 | 51.52 | 145.18 | 3.05 | 0.00 | 0.00 | 0.00 |
| September | 68.57 | 18.71 | 49.85 | 140.99 | 3.01 | 0.00 | 0.00 | 0.00 |
| October | 64.32 | 16.51 | 47.81 | 126.16 | 4.37 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 17.27 | 45.03 | 122.71 | 6.41 | 0.00 | 0.00 | 0.00 |
| December | 63.64 | 20.44 | 43.20 | 123.46 | 12.57 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 71.78 | 22.71 | 49.08 | 146.23 | 4.92 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62.31 | 14.90 | 43.20 | 122.71 | 0.88 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.79 | 32.81 | 52.39 | 179.38 | 12.57 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 110.88 | 16.97 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 124.13 | 11.50 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 134.47 | 6.32 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 156.00 | 1.42 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 198.25 | 2.79 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 232.67 | 3.01 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 183.06 | 6.80 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 152.91 | 4.70 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 134.17 | 4.63 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 119.86 | 6.64 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 113.90 | 9.86 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 106.57 | 20.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 147.30 | 7.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 106.57 | 1.42 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 232.67 | 20.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 113.41 | 16.87 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 127.08 | 11.29 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 137.79 | 6.13 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 159.74 | 1.37 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 201.54 | 2.70 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 236.06 | 2.91 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 185.70 | 6.62 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 155.78 | 4.58 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 137.03 | 4.47 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 122.29 | 6.49 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 116.31 | 9.74 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 108.89 | 20.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 150.19 | 7.77 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 108.89 | 1.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 236.06 | 20.00 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.49 | 0.00 | 53.49 | 113.39 | 16.86 | 0.00 | 0.00 | 0.00 |
| February | 57.06 | 0.00 | 57.06 | 127.06 | 11.28 | 0.00 | 0.00 | 0.00 |
| March | 58.61 | 0.01 | 58.59 | 137.78 | 6.12 | 0.00 | 0.00 | 0.00 |
| April | 64.55 | 1.22 | 63.33 | 159.73 | 1.37 | 0.00 | 0.00 | 0.00 |
| May | 81.93 | 8.94 | 72.99 | 201.53 | 2.70 | 0.00 | 0.00 | 0.00 |
| June | 99.49 | 19.87 | 79.62 | 236.05 | 2.91 | 0.00 | 0.00 | 0.00 |
| July | 85.52 | 8.71 | 76.82 | 185.69 | 6.61 | 0.00 | 0.00 | 0.00 |
| August | 71.18 | 3.50 | 67.69 | 155.76 | 4.57 | 0.00 | 0.00 | 0.00 |
| September | 60.25 | 0.08 | 60.17 | 137.02 | 4.47 | 0.00 | 0.00 | 0.00 |
| October | 57.96 | 0.00 | 57.96 | 122.28 | 6.48 | 0.00 | 0.00 | 0.00 |
| November | 54.84 | 0.00 | 54.84 | 116.30 | 9.73 | 0.00 | 0.00 | 0.00 |
| December | 51.96 | 0.00 | 51.96 | 108.87 | 19.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.44 | 3.54 | 62.91 | 150.18 | 7.76 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51.96 | 0.00 | 51.96 | 108.87 | 1.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 99.49 | 19.87 | 79.62 | 236.05 | 19.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 277.37 | 16.38 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 256.62 | 10.73 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 191.94 | 5.40 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 156.92 | 1.34 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 158.76 | 2.55 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 156.59 | 2.75 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 139.06 | 6.25 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 135.14 | 4.12 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 152.30 | 4.48 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 182.21 | 6.84 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 233.46 | 10.21 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 274.14 | 20.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 192.55 | 7.60 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 135.14 | 1.34 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 277.37 | 20.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 140.36 | 57.82 | 82.54 | 277.36 | 16.36 | 0.00 | 0.00 | 0.00 |
| February | 121.34 | 40.29 | 81.04 | 256.61 | 10.72 | 0.00 | 0.00 | 0.00 |
| March | 82.36 | 11.35 | 71.01 | 191.94 | 5.39 | 0.00 | 0.00 | 0.00 |
| April | 61.97 | 0.66 | 61.31 | 156.92 | 1.34 | 0.00 | 0.00 | 0.00 |
| May | 61.23 | 0.00 | 61.23 | 158.75 | 2.55 | 0.00 | 0.00 | 0.00 |
| June | 61.01 | 0.00 | 61.01 | 156.58 | 2.74 | 0.00 | 0.00 | 0.00 |
| July | 62.84 | 0.00 | 62.84 | 139.05 | 6.24 | 0.00 | 0.00 | 0.00 |
| August | 61.12 | 0.04 | 61.09 | 135.13 | 4.12 | 0.00 | 0.00 | 0.00 |
| September | 67.41 | 1.86 | 65.56 | 152.29 | 4.48 | 0.00 | 0.00 | 0.00 |
| October | 88.05 | 13.56 | 74.49 | 182.20 | 6.83 | 0.00 | 0.00 | 0.00 |
| November | 116.40 | 36.30 | 80.10 | 233.45 | 10.21 | 0.00 | 0.00 | 0.00 |
| December | 141.11 | 59.79 | 81.33 | 274.12 | 20.05 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 88.63 | 18.39 | 70.24 | 192.54 | 7.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.01 | 0.00 | 61.01 | 135.13 | 1.34 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 141.11 | 59.79 | 82.54 | 277.36 | 20.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 16.32 | 5.53 | 10.79 | 29.61 | 4.20 | 309.67 | 0.00 | 0.00 |
| February | 18.41 | 6.72 | 11.69 | 34.44 | 3.19 | 267.83 | 0.00 | 0.00 |
| March | 20.14 | 7.87 | 12.27 | 38.38 | 2.23 | 249.83 | 0.00 | 0.00 |
| April | 20.35 | 7.78 | 12.57 | 39.67 | 0.89 | 102.50 | 0.00 | 0.00 |
| May | 17.48 | 5.29 | 12.19 | 35.26 | 1.30 | 158.00 | 0.00 | 0.00 |
| June | 18.63 | 6.14 | 12.49 | 37.08 | 1.41 | 168.50 | 0.00 | 0.00 |
| July | 15.92 | 3.57 | 12.34 | 29.98 | 2.46 | 294.83 | 0.00 | 0.00 |
| August | 17.50 | 5.14 | 12.36 | 32.45 | 2.13 | 306.83 | 0.00 | 0.00 |
| September | 16.45 | 4.49 | 11.96 | 31.31 | 2.07 | 269.00 | 0.00 | 0.00 |
| October | 15.44 | 3.96 | 11.47 | 27.93 | 2.68 | 331.17 | 0.00 | 0.00 |
| November | 14.95 | 4.14 | 10.81 | 27.16 | 3.15 | 318.00 | 0.00 | 0.00 |
| December | 15.27 | 4.90 | 10.37 | 27.57 | 4.83 | 334.17 | 0.00 | 0.00 |
| Annual Sum or Average | 17.22 | 5.45 | 11.78 | 32.54 | 2.55 | 3110.33 | 0.00 | 0.00 |
| Minimum of Months | 14.95 | 3.57 | 10.37 | 27.16 | 0.89 | 102.50 | 0.00 | 0.00 |
| Maximum of Months | 20.35 | 7.87 | 12.57 | 39.67 | 4.83 | 334.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 48.61 | 16.46 | 32.15 | 86.35 | 15.24 | 121.67 | 0.00 | 0.00 |
| February | 54.84 | 20.01 | 34.82 | 100.19 | 12.60 | 93.00 | 0.00 | 0.00 |
| March | 59.98 | 23.45 | 36.54 | 111.74 | 9.72 | 101.50 | 0.00 | 0.00 |
| April | 60.60 | 23.16 | 37.44 | 114.87 | 5.19 | 163.50 | 0.00 | 0.00 |
| May | 52.06 | 15.74 | 36.32 | 101.20 | 5.91 | 189.17 | 0.00 | 0.00 |
| June | 55.49 | 18.29 | 37.20 | 107.07 | 6.49 | 205.33 | 0.00 | 0.00 |
| July | 47.41 | 10.65 | 36.77 | 86.96 | 9.60 | 158.83 | 0.00 | 0.00 |
| August | 52.12 | 15.30 | 36.82 | 94.06 | 8.80 | 233.67 | 0.00 | 0.00 |
| September | 49.00 | 13.37 | 35.63 | 90.83 | 8.46 | 207.67 | 0.00 | 0.00 |
| October | 45.97 | 11.80 | 34.17 | 81.20 | 10.37 | 207.00 | 0.00 | 0.00 |
| November | 44.53 | 12.34 | 32.18 | 79.10 | 11.88 | 170.00 | 0.00 | 0.00 |
| December | 45.48 | 14.61 | 30.87 | 80.40 | 17.02 | 145.50 | 0.00 | 0.00 |
| Annual Sum or Average | 51.30 | 16.23 | 35.07 | 94.42 | 10.11 | 1996.83 | 0.00 | 0.00 |
| Minimum of Months | 44.53 | 10.65 | 30.87 | 79.10 | 5.19 | 93.00 | 0.00 | 0.00 |
| Maximum of Months | 60.60 | 23.45 | 37.44 | 114.87 | 17.02 | 233.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 16.32 | 5.53 | 10.79 | 30.11 | 4.16 | 319.33 | 0.00 | 0.00 |
| February | 18.41 | 6.72 | 11.69 | 35.05 | 3.17 | 277.83 | 0.00 | 0.00 |
| March | 20.14 | 7.87 | 12.27 | 39.17 | 2.15 | 241.17 | 0.00 | 0.00 |
| April | 20.35 | 7.78 | 12.57 | 40.72 | 0.86 | 93.33 | 0.00 | 0.00 |
| May | 17.48 | 5.29 | 12.19 | 36.29 | 1.21 | 143.83 | 0.00 | 0.00 |
| June | 18.63 | 6.14 | 12.49 | 38.09 | 1.29 | 147.67 | 0.00 | 0.00 |
| July | 15.92 | 3.57 | 12.34 | 30.70 | 2.34 | 278.17 | 0.00 | 0.00 |
| August | 17.50 | 5.14 | 12.36 | 33.13 | 2.00 | 267.67 | 0.00 | 0.00 |
| September | 16.45 | 4.49 | 11.96 | 32.06 | 1.93 | 241.67 | 0.00 | 0.00 |
| October | 15.44 | 3.96 | 11.47 | 28.54 | 2.56 | 311.17 | 0.00 | 0.00 |
| November | 14.95 | 4.14 | 10.81 | 27.72 | 3.07 | 303.50 | 0.00 | 0.00 |
| December | 15.27 | 4.90 | 10.37 | 28.00 | 4.81 | 340.17 | 0.00 | 0.00 |
| Annual Sum or Average | 17.22 | 5.45 | 11.78 | 33.27 | 2.46 | 2965.50 | 0.00 | 0.00 |
| Minimum of Months | 14.95 | 3.57 | 10.37 | 27.72 | 0.86 | 93.33 | 0.00 | 0.00 |
| Maximum of Months | 20.35 | 7.87 | 12.57 | 40.72 | 4.81 | 340.17 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.748613E+09 | 50536175.09 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.624608E+09 | 32306002.64 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.515037E+09 | 19751219.12 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.403305E+09 | 4889986.41 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.422515E+09 | 9062829.41 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.402487E+09 | 9257832.41 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.372699E+09 | 21532375.98 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.360047E+09 | 15205565.28 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.394914E+09 | 15392130.03 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.490946E+09 | 22879315.45 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.609279E+09 | 31758966.16 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.739757E+09 | 60375291.34 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.608421E+10 | 0.292948E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.360047E+09 | 4889986.41 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.748613E+09 | 60375291.34 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.184634E+09 | 65202191.82 | 0.119432E+09 | 0.363823E+09 | 35401853.59 |
| February | 0.182691E+09 | 64659888.95 | 0.118031E+09 | 0.369236E+09 | 22674016.64 |
| March | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.467597E+09 | 14352705.77 |
| April | 0.220199E+09 | 84168001.63 | 0.136031E+09 | 0.467619E+09 | 3308679.83 |
| May | 0.193837E+09 | 57412683.88 | 0.136424E+09 | 0.431032E+09 | 5858838.84 |
| June | 0.203177E+09 | 69965590.50 | 0.133212E+09 | 0.442450E+09 | 6009353.11 |
| July | 0.179183E+09 | 42298116.40 | 0.136885E+09 | 0.369557E+09 | 14000616.61 |
| August | 0.194913E+09 | 57792889.10 | 0.137120E+09 | 0.391304E+09 | 9861890.06 |
| September | 0.176338E+09 | 48792682.50 | 0.127546E+09 | 0.365060E+09 | 9952272.97 |
| October | 0.171292E+09 | 44135038.74 | 0.127157E+09 | 0.338350E+09 | 14857855.20 |
| November | 0.161424E+09 | 43864372.98 | 0.117559E+09 | 0.319561E+09 | 21003424.30 |
| December | 0.171043E+09 | 56014806.47 | 0.115028E+09 | 0.335791E+09 | 41255434.21 |
| Annual Sum or Average | 0.226558E+10 | 0.723992E+09 | 0.154159E+10 | 0.466138E+10 | 0.198537E+09 |
| Minimum of Months | 0.161424E+09 | 42298116.40 | 0.115028E+09 | 0.319561E+09 | 3308679.83 |
| Maximum of Months | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.467619E+09 | 41255434.21 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.184634E+09 | 65202191.82 | 0.119432E+09 | 0.367993E+09 | 33380008.04 |
| February | 0.182691E+09 | 64659888.95 | 0.118031E+09 | 0.372482E+09 | 21314220.52 |
| March | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.469246E+09 | 13782643.35 |
| April | 0.220199E+09 | 84168001.63 | 0.136031E+09 | 0.467245E+09 | 3342604.10 |
| May | 0.193837E+09 | 57412683.88 | 0.136424E+09 | 0.429269E+09 | 6127212.77 |
| June | 0.203177E+09 | 69965590.50 | 0.133212E+09 | 0.439322E+09 | 6401490.46 |
| July | 0.179183E+09 | 42298116.40 | 0.136885E+09 | 0.367940E+09 | 14589345.06 |
| August | 0.194913E+09 | 57792889.10 | 0.137120E+09 | 0.390337E+09 | 10124259.88 |
| September | 0.176338E+09 | 48792682.50 | 0.127546E+09 | 0.365434E+09 | 9905300.43 |
| October | 0.171292E+09 | 44135038.74 | 0.127157E+09 | 0.340044E+09 | 14262599.50 |
| November | 0.161424E+09 | 43864372.98 | 0.117559E+09 | 0.322709E+09 | 19801856.19 |
| December | 0.171043E+09 | 56014806.47 | 0.115028E+09 | 0.339961E+09 | 39186357.15 |
| Annual Sum or Average | 0.226558E+10 | 0.723992E+09 | 0.154159E+10 | 0.467198E+10 | 0.192218E+09 |
| Minimum of Months | 0.161424E+09 | 42298116.40 | 0.115028E+09 | 0.322709E+09 | 3342604.10 |
| Maximum of Months | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.469246E+09 | 39186357.15 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.304958E+09 | 51039792.56 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.308149E+09 | 32934382.51 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.368971E+09 | 21191632.10 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.412100E+09 | 5147002.56 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.539473E+09 | 9668800.29 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.612008E+09 | 9977033.98 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.499617E+09 | 22709016.98 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.416521E+09 | 16415811.77 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.354814E+09 | 15378190.62 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.328291E+09 | 21778019.20 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.302387E+09 | 30174677.93 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.292612E+09 | 59712050.58 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.473990E+10 | 0.296126E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.292612E+09 | 5147002.56 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.612008E+09 | 59712050.58 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.695581E+09 | 0.121208E+09 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.576457E+09 | 94604845.45 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.464142E+09 | 86263395.45 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.332245E+09 | 56190895.47 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.346781E+09 | 59472896.02 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.334814E+09 | 60639679.85 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.314193E+09 | 85319322.07 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.307496E+09 | 78353368.56 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.339086E+09 | 76492642.72 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.438051E+09 | 91624976.96 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.558223E+09 | 96048355.17 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.691142E+09 | 0.128331E+09 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.539821E+10 | 0.103455E+10 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.307496E+09 | 56190895.47 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.695581E+09 | 0.128331E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.182168E+09 | 61675549.49 | 0.120493E+09 | 0.321455E+09 | 79395355.10 |
| February | 0.185635E+09 | 67745811.95 | 0.117889E+09 | 0.340254E+09 | 61392245.92 |
| March | 0.224817E+09 | 87874007.30 | 0.136943E+09 | 0.427390E+09 | 55097171.90 |
| April | 0.219778E+09 | 83994199.05 | 0.135784E+09 | 0.422484E+09 | 36030924.41 |
| May | 0.195118E+09 | 59006733.03 | 0.136111E+09 | 0.385437E+09 | 38164413.78 |
| June | 0.201254E+09 | 66322556.51 | 0.134932E+09 | 0.396662E+09 | 39101096.58 |
| July | 0.177696E+09 | 39900904.34 | 0.137795E+09 | 0.327245E+09 | 54124475.78 |
| August | 0.195337E+09 | 57353203.69 | 0.137983E+09 | 0.359307E+09 | 50126324.01 |
| September | 0.177722E+09 | 48504115.16 | 0.129218E+09 | 0.331856E+09 | 48718157.38 |
| October | 0.172288E+09 | 44232434.88 | 0.128055E+09 | 0.306007E+09 | 59596152.10 |
| November | 0.161498E+09 | 44772595.62 | 0.116725E+09 | 0.286597E+09 | 63111954.01 |
| December | 0.170452E+09 | 54746880.90 | 0.115705E+09 | 0.299815E+09 | 84286502.41 |
| Annual Sum or Average | 0.226376E+10 | 0.716129E+09 | 0.154763E+10 | 0.420451E+10 | 0.669145E+09 |
| Minimum of Months | 0.161498E+09 | 39900904.34 | 0.115705E+09 | 0.286597E+09 | 36030924.41 |
| Maximum of Months | 0.224817E+09 | 87874007.30 | 0.137983E+09 | 0.427390E+09 | 84286502.41 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.182168E+09 | 61675549.49 | 0.120493E+09 | 0.360776E+09 | 30824085.57 |
| February | 0.185635E+09 | 67745811.95 | 0.117889E+09 | 0.376301E+09 | 19402939.71 |
| March | 0.224817E+09 | 87874007.30 | 0.136943E+09 | 0.465075E+09 | 11875706.28 |
| April | 0.219778E+09 | 83994199.05 | 0.135784E+09 | 0.470880E+09 | 3106791.13 |
| May | 0.195118E+09 | 59006733.03 | 0.136111E+09 | 0.434730E+09 | 6240150.72 |
| June | 0.201254E+09 | 66322556.51 | 0.134932E+09 | 0.438230E+09 | 6460659.32 |
| July | 0.177696E+09 | 39900904.34 | 0.137795E+09 | 0.365869E+09 | 14689661.87 |
| August | 0.195337E+09 | 57353203.69 | 0.137983E+09 | 0.393711E+09 | 10532630.75 |
| September | 0.177722E+09 | 48504115.16 | 0.129218E+09 | 0.370479E+09 | 9872324.78 |
| October | 0.172288E+09 | 44232434.88 | 0.128055E+09 | 0.343311E+09 | 14062780.42 |
| November | 0.161498E+09 | 44772595.62 | 0.116725E+09 | 0.323240E+09 | 19300060.42 |
| December | 0.170452E+09 | 54746880.90 | 0.115705E+09 | 0.335768E+09 | 37041140.04 |
| Annual Sum or Average | 0.226376E+10 | 0.716129E+09 | 0.154763E+10 | 0.467837E+10 | 0.183409E+09 |
| Minimum of Months | 0.161498E+09 | 39900904.34 | 0.115705E+09 | 0.323240E+09 | 3106791.13 |
| Maximum of Months | 0.224817E+09 | 87874007.30 | 0.137983E+09 | 0.470880E+09 | 37041140.04 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.304539E+09 | 50604471.70 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.307710E+09 | 32594716.16 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.368760E+09 | 20742761.56 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.411951E+09 | 5027099.81 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.539164E+09 | 9556684.81 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.611669E+09 | 9885518.66 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.499232E+09 | 22486438.89 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.416041E+09 | 16228350.14 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.354379E+09 | 15240354.68 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.328012E+09 | 21563003.61 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.302079E+09 | 29984557.50 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.292219E+09 | 59327857.59 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.473575E+10 | 0.293242E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.292219E+09 | 5027099.81 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.611669E+09 | 59327857.59 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.309958E+09 | 48731569.71 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.313512E+09 | 30645754.00 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.376354E+09 | 18948366.43 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.421100E+09 | 4433815.86 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.547535E+09 | 8607900.87 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.620097E+09 | 8884200.03 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.505664E+09 | 20578249.44 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.423291E+09 | 14672571.86 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.361330E+09 | 13594062.63 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.333675E+09 | 19776996.85 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.307369E+09 | 28241014.90 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.297270E+09 | 57516475.53 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.481716E+10 | 0.274631E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.297270E+09 | 4433815.86 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.620097E+09 | 57516475.53 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.309942E+09 | 48717985.25 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.313496E+09 | 30635017.44 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.376349E+09 | 18935277.01 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.421093E+09 | 4430255.54 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.547522E+09 | 8604020.65 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.620085E+09 | 8883629.95 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.505649E+09 | 20572447.18 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.423273E+09 | 14668818.22 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.361312E+09 | 13591915.96 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.333666E+09 | 19770588.93 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.307358E+09 | 28236506.65 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.297256E+09 | 57503942.95 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.481700E+10 | 0.274550E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.297256E+09 | 4430255.54 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.620085E+09 | 57503942.95 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.753099E+09 | 48584808.05 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.629637E+09 | 30369967.09 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.522415E+09 | 17824193.68 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.412505E+09 | 4301239.21 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.430852E+09 | 8037160.95 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.411222E+09 | 8224658.65 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.378896E+09 | 19427983.13 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.367071E+09 | 13549086.87 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.401338E+09 | 13705475.74 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.496036E+09 | 21050666.67 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.613817E+09 | 30093079.07 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.743845E+09 | 58510985.65 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.616073E+10 | 0.273679E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.367071E+09 | 4301239.21 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.753099E+09 | 58510985.65 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.750399E+09 | 50822318.82 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.627089E+09 | 32251239.74 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.519199E+09 | 19434723.67 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.408124E+09 | 4860656.29 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.426607E+09 | 8953335.36 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.407247E+09 | 9129410.66 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.375733E+09 | 21256185.68 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.363640E+09 | 15017819.60 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.398078E+09 | 15216265.90 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.493094E+09 | 23135605.60 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.611132E+09 | 32078766.25 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.741426E+09 | 60668950.01 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.612177E+10 | 0.292825E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.363640E+09 | 4860656.29 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.750399E+09 | 60668950.01 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.751099E+09 | 46072670.61 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.627885E+09 | 28163079.27 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.520632E+09 | 16203015.10 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.412097E+09 | 3848840.84 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.431405E+09 | 7129145.28 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.411942E+09 | 7387134.07 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.378796E+09 | 17574236.17 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.367538E+09 | 11850363.64 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.401196E+09 | 12152839.25 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.494797E+09 | 19091333.41 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.612479E+09 | 27822066.89 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.742195E+09 | 55854203.52 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.615206E+10 | 0.253149E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.367538E+09 | 3848840.84 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.751099E+09 | 55854203.52 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.184634E+09 | 65202191.82 | 0.119432E+09 | 0.365809E+09 | 32417943.92 |
| February | 0.182691E+09 | 64659888.95 | 0.118031E+09 | 0.371350E+09 | 19885143.60 |
| March | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.470339E+09 | 12083386.80 |
| April | 0.220199E+09 | 84168001.63 | 0.136031E+09 | 0.471936E+09 | 2585810.75 |
| May | 0.193837E+09 | 57412683.88 | 0.136424E+09 | 0.435901E+09 | 4604267.90 |
| June | 0.203177E+09 | 69965590.50 | 0.133212E+09 | 0.447611E+09 | 4809727.33 |
| July | 0.179183E+09 | 42298116.40 | 0.136885E+09 | 0.372844E+09 | 11439733.83 |
| August | 0.194913E+09 | 57792889.10 | 0.137120E+09 | 0.395340E+09 | 7703295.79 |
| September | 0.176338E+09 | 48792682.50 | 0.127546E+09 | 0.368695E+09 | 7872785.05 |
| October | 0.171292E+09 | 44135038.74 | 0.127157E+09 | 0.340844E+09 | 12346698.79 |
| November | 0.161424E+09 | 43864372.98 | 0.117559E+09 | 0.321935E+09 | 18317952.43 |
| December | 0.171043E+09 | 56014806.47 | 0.115028E+09 | 0.337818E+09 | 38134763.25 |
| Annual Sum or Average | 0.226558E+10 | 0.723992E+09 | 0.154159E+10 | 0.470042E+10 | 0.172202E+09 |
| Minimum of Months | 0.161424E+09 | 42298116.40 | 0.115028E+09 | 0.321935E+09 | 2585810.75 |
| Maximum of Months | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.471936E+09 | 38134763.25 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.184634E+09 | 65202191.82 | 0.119432E+09 | 0.369773E+09 | 30925209.36 |
| February | 0.182691E+09 | 64659888.95 | 0.118031E+09 | 0.374419E+09 | 18936965.39 |
| March | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.471882E+09 | 11679660.62 |
| April | 0.220199E+09 | 84168001.63 | 0.136031E+09 | 0.471685E+09 | 2587644.09 |
| May | 0.193837E+09 | 57412683.88 | 0.136424E+09 | 0.434410E+09 | 4774321.09 |
| June | 0.203177E+09 | 69965590.50 | 0.133212E+09 | 0.444907E+09 | 5060530.44 |
| July | 0.179183E+09 | 42298116.40 | 0.136885E+09 | 0.371435E+09 | 11835487.08 |
| August | 0.194913E+09 | 57792889.10 | 0.137120E+09 | 0.394518E+09 | 7850197.15 |
| September | 0.176338E+09 | 48792682.50 | 0.127546E+09 | 0.369117E+09 | 7812242.49 |
| October | 0.171292E+09 | 44135038.74 | 0.127157E+09 | 0.342464E+09 | 11883276.76 |
| November | 0.161424E+09 | 43864372.98 | 0.117559E+09 | 0.324903E+09 | 17423645.93 |
| December | 0.171043E+09 | 56014806.47 | 0.115028E+09 | 0.341800E+09 | 36607576.96 |
| Annual Sum or Average | 0.226558E+10 | 0.723992E+09 | 0.154159E+10 | 0.471131E+10 | 0.167377E+09 |
| Minimum of Months | 0.161424E+09 | 42298116.40 | 0.115028E+09 | 0.324903E+09 | 2587644.09 |
| Maximum of Months | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.471882E+09 | 36607576.96 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.308739E+09 | 47158843.54 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.312173E+09 | 29230745.61 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.374505E+09 | 17895114.37 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.419945E+09 | 3956660.46 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.547281E+09 | 7606756.59 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.619829E+09 | 7885306.29 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.504987E+09 | 18586127.34 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.423335E+09 | 13032185.30 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.361225E+09 | 12099763.86 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.332881E+09 | 18048531.33 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.306556E+09 | 26421217.44 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.296429E+09 | 55610799.93 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.480789E+10 | 0.257532E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.296429E+09 | 3956660.46 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.619829E+09 | 55610799.93 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.750691E+09 | 45612211.87 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.627487E+09 | 27832641.33 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.520531E+09 | 15831604.23 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.412030E+09 | 3776551.02 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.431124E+09 | 7027251.99 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.411626E+09 | 7298995.01 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.378450E+09 | 17348532.53 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.367058E+09 | 11666105.02 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.400797E+09 | 12011627.25 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.494509E+09 | 18866845.71 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.612192E+09 | 27602970.02 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.741778E+09 | 55443744.31 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.614827E+10 | 0.250319E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.367058E+09 | 3776551.02 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.750691E+09 | 55443744.31 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.182168E+09 | 61675549.49 | 0.120493E+09 | 0.358706E+09 | 29793431.36 |
| February | 0.185635E+09 | 67745811.95 | 0.117889E+09 | 0.375474E+09 | 17954734.01 |
| March | 0.224817E+09 | 87874007.30 | 0.136943E+09 | 0.466539E+09 | 10120358.43 |
| April | 0.219778E+09 | 83994199.05 | 0.135784E+09 | 0.476063E+09 | 2424593.58 |
| May | 0.195118E+09 | 59006733.03 | 0.136111E+09 | 0.441447E+09 | 4752662.31 |
| June | 0.201254E+09 | 66322556.51 | 0.134932E+09 | 0.446244E+09 | 4848029.85 |
| July | 0.177696E+09 | 39900904.34 | 0.137795E+09 | 0.370881E+09 | 11614147.72 |
| August | 0.195337E+09 | 57353203.69 | 0.137983E+09 | 0.398680E+09 | 8192037.51 |
| September | 0.177722E+09 | 48504115.16 | 0.129218E+09 | 0.373861E+09 | 7834460.71 |
| October | 0.172288E+09 | 44232434.88 | 0.128055E+09 | 0.344240E+09 | 12179926.78 |
| November | 0.161498E+09 | 44772595.62 | 0.116725E+09 | 0.322525E+09 | 17857669.57 |
| December | 0.170452E+09 | 54746880.90 | 0.115705E+09 | 0.333683E+09 | 36000565.56 |
| Annual Sum or Average | 0.226376E+10 | 0.716129E+09 | 0.154763E+10 | 0.470834E+10 | 0.163573E+09 |
| Minimum of Months | 0.161498E+09 | 39900904.34 | 0.115705E+09 | 0.322525E+09 | 2424593.58 |
| Maximum of Months | 0.224817E+09 | 87874007.30 | 0.137983E+09 | 0.476063E+09 | 36000565.56 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.182168E+09 | 61675549.49 | 0.120493E+09 | 0.362884E+09 | 28412954.11 |
| February | 0.185635E+09 | 67745811.95 | 0.117889E+09 | 0.378710E+09 | 17100706.26 |
| March | 0.224817E+09 | 87874007.30 | 0.136943E+09 | 0.468181E+09 | 9738811.76 |
| April | 0.219778E+09 | 83994199.05 | 0.135784E+09 | 0.475801E+09 | 2426056.13 |
| May | 0.195118E+09 | 59006733.03 | 0.136111E+09 | 0.439958E+09 | 4923227.93 |
| June | 0.201254E+09 | 66322556.51 | 0.134932E+09 | 0.443611E+09 | 5105113.14 |
| July | 0.177696E+09 | 39900904.34 | 0.137795E+09 | 0.369502E+09 | 12006990.57 |
| August | 0.195337E+09 | 57353203.69 | 0.137983E+09 | 0.397890E+09 | 8339513.47 |
| September | 0.177722E+09 | 48504115.16 | 0.129218E+09 | 0.374281E+09 | 7776801.13 |
| October | 0.172288E+09 | 44232434.88 | 0.128055E+09 | 0.345879E+09 | 11725222.36 |
| November | 0.161498E+09 | 44772595.62 | 0.116725E+09 | 0.325533E+09 | 16983774.35 |
| December | 0.170452E+09 | 54746880.90 | 0.115705E+09 | 0.337797E+09 | 34564725.58 |
| Annual Sum or Average | 0.226376E+10 | 0.716129E+09 | 0.154763E+10 | 0.472003E+10 | 0.159104E+09 |
| Minimum of Months | 0.161498E+09 | 39900904.34 | 0.115705E+09 | 0.325533E+09 | 2426056.13 |
| Maximum of Months | 0.224817E+09 | 87874007.30 | 0.137983E+09 | 0.475801E+09 | 34564725.58 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.308317E+09 | 46724900.53 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.311747E+09 | 28911510.38 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.374341E+09 | 17509933.51 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.419844E+09 | 3873268.41 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.546999E+09 | 7500605.10 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.619506E+09 | 7793574.08 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.504599E+09 | 18358077.62 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.422871E+09 | 12845287.69 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.360818E+09 | 11958736.49 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.332589E+09 | 17833045.83 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.306254E+09 | 26209916.02 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.296023E+09 | 55228246.54 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.480391E+10 | 0.254747E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.296023E+09 | 3873268.41 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.619506E+09 | 55228246.54 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.313278E+09 | 45616463.23 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.317124E+09 | 27734970.79 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.381362E+09 | 16379931.66 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.427953E+09 | 3560540.18 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.554196E+09 | 6941833.97 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.626640E+09 | 7237892.92 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.510010E+09 | 17306860.57 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.428986E+09 | 12062024.02 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.366708E+09 | 11100717.35 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.337627E+09 | 16785949.39 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.310934E+09 | 25212506.74 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.300515E+09 | 54252495.90 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.487533E+10 | 0.244192E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.300515E+09 | 3560540.18 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.626640E+09 | 54252495.90 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.313261E+09 | 45601195.74 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.317108E+09 | 27722514.44 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.381354E+09 | 16366075.35 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.427947E+09 | 3557434.24 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.554185E+09 | 6937971.18 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.626629E+09 | 7235834.12 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.509996E+09 | 17299806.30 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.428968E+09 | 12056990.59 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.366693E+09 | 11097365.70 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.337617E+09 | 16779107.62 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.310922E+09 | 25205896.73 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.300499E+09 | 54239033.11 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.487518E+10 | 0.244099E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.300499E+09 | 3557434.24 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.626629E+09 | 54239033.11 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.755295E+09 | 44709973.46 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.632646E+09 | 26859000.42 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.527542E+09 | 14792033.17 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.420412E+09 | 3495674.70 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.438730E+09 | 6475848.96 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.419440E+09 | 6734099.54 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.384073E+09 | 16266020.05 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.373507E+09 | 10885182.43 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.406705E+09 | 11160227.90 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.499389E+09 | 17866518.13 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.616559E+09 | 26718497.65 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.745878E+09 | 54637654.90 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.622018E+10 | 0.240601E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.373507E+09 | 3495674.70 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.755295E+09 | 54637654.90 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.755281E+09 | 44695583.51 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.632632E+09 | 26848094.65 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.527537E+09 | 14778725.33 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.420407E+09 | 3492938.11 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.438719E+09 | 6472304.58 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.419427E+09 | 6732234.94 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.384059E+09 | 16259243.36 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.373489E+09 | 10879841.11 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.406689E+09 | 11156828.06 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.499380E+09 | 17859541.24 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.616549E+09 | 26711889.55 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.745864E+09 | 54624599.36 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.622003E+10 | 0.240512E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.373489E+09 | 3492938.11 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.755281E+09 | 54624599.36 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.737399E+09 | 44755851.25 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.614586E+09 | 26766658.60 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.505280E+09 | 15388871.67 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.396741E+09 | 3665835.77 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.416319E+09 | 7190060.28 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.396846E+09 | 7527880.59 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.365717E+09 | 17600308.31 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.354582E+09 | 11643480.99 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.387885E+09 | 12252228.86 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.482149E+09 | 19072609.88 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.599742E+09 | 27065555.29 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.729368E+09 | 54407728.29 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.598661E+10 | 0.247337E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.354582E+09 | 3665835.77 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.737399E+09 | 54407728.29 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.184634E+09 | 65202191.82 | 0.119432E+09 | 0.356692E+09 | 31404545.48 |
| February | 0.182691E+09 | 64659888.95 | 0.118031E+09 | 0.362446E+09 | 18924513.21 |
| March | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.460179E+09 | 11690809.62 |
| April | 0.220199E+09 | 84168001.63 | 0.136031E+09 | 0.461443E+09 | 2459126.97 |
| May | 0.193837E+09 | 57412683.88 | 0.136424E+09 | 0.425469E+09 | 4628201.52 |
| June | 0.203177E+09 | 69965590.50 | 0.133212E+09 | 0.437091E+09 | 4875268.61 |
| July | 0.179183E+09 | 42298116.40 | 0.136885E+09 | 0.363659E+09 | 11410497.54 |
| August | 0.194913E+09 | 57792889.10 | 0.137120E+09 | 0.386205E+09 | 7535972.91 |
| September | 0.176338E+09 | 48792682.50 | 0.127546E+09 | 0.359477E+09 | 7875648.10 |
| October | 0.171292E+09 | 44135038.74 | 0.127157E+09 | 0.332417E+09 | 12258394.46 |
| November | 0.161424E+09 | 43864372.98 | 0.117559E+09 | 0.313390E+09 | 17685339.25 |
| December | 0.171043E+09 | 56014806.47 | 0.115028E+09 | 0.329181E+09 | 36951448.11 |
| Annual Sum or Average | 0.226558E+10 | 0.723992E+09 | 0.154159E+10 | 0.458765E+10 | 0.167700E+09 |
| Minimum of Months | 0.161424E+09 | 42298116.40 | 0.115028E+09 | 0.313390E+09 | 2459126.97 |
| Maximum of Months | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.461443E+09 | 36951448.11 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.184634E+09 | 65202191.82 | 0.119432E+09 | 0.362229E+09 | 30184576.21 |
| February | 0.182691E+09 | 64659888.95 | 0.118031E+09 | 0.366653E+09 | 18212860.01 |
| March | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.462217E+09 | 11377988.25 |
| April | 0.220199E+09 | 84168001.63 | 0.136031E+09 | 0.461097E+09 | 2458535.87 |
| May | 0.193837E+09 | 57412683.88 | 0.136424E+09 | 0.423513E+09 | 4747741.38 |
| June | 0.203177E+09 | 69965590.50 | 0.133212E+09 | 0.433612E+09 | 5064554.20 |
| July | 0.179183E+09 | 42298116.40 | 0.136885E+09 | 0.361733E+09 | 11725944.39 |
| August | 0.194913E+09 | 57792889.10 | 0.137120E+09 | 0.385112E+09 | 7649812.51 |
| September | 0.176338E+09 | 48792682.50 | 0.127546E+09 | 0.360037E+09 | 7832294.76 |
| October | 0.171292E+09 | 44135038.74 | 0.127157E+09 | 0.334588E+09 | 11915185.95 |
| November | 0.161424E+09 | 43864372.98 | 0.117559E+09 | 0.317485E+09 | 17032783.75 |
| December | 0.171043E+09 | 56014806.47 | 0.115028E+09 | 0.334738E+09 | 35638080.78 |
| Annual Sum or Average | 0.226558E+10 | 0.723992E+09 | 0.154159E+10 | 0.460301E+10 | 0.163840E+09 |
| Minimum of Months | 0.161424E+09 | 42298116.40 | 0.115028E+09 | 0.317485E+09 | 2458535.87 |
| Maximum of Months | 0.226850E+09 | 89685681.23 | 0.137164E+09 | 0.462217E+09 | 35638080.78 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.297716E+09 | 46146087.22 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.300969E+09 | 28296350.18 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.360421E+09 | 17515949.09 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.404440E+09 | 3776102.74 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.531399E+09 | 7619193.10 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.603627E+09 | 7952015.04 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.490920E+09 | 18557876.35 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.410259E+09 | 12904609.67 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.348368E+09 | 12233984.10 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.321512E+09 | 18144620.97 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.295709E+09 | 25891298.58 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.286169E+09 | 54255384.30 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.465151E+10 | 0.253293E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.286169E+09 | 3776102.74 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.603627E+09 | 54255384.30 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.736717E+09 | 44012393.84 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.614001E+09 | 26292947.70 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.505168E+09 | 14884442.94 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.396720E+09 | 3586211.51 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.415947E+09 | 7056764.76 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.396330E+09 | 7368069.26 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.365157E+09 | 17259457.10 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.353852E+09 | 11356130.32 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.387300E+09 | 12010908.63 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.481680E+09 | 18717041.89 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.599322E+09 | 26727330.43 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.728646E+09 | 53726903.78 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.598084E+10 | 0.242999E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.353852E+09 | 3586211.51 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.736717E+09 | 53726903.78 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.182168E+09 | 61675549.49 | 0.120493E+09 | 0.349399E+09 | 28706073.15 |
| February | 0.185635E+09 | 67745811.95 | 0.117889E+09 | 0.366390E+09 | 16902032.46 |
| March | 0.224817E+09 | 87874007.30 | 0.136943E+09 | 0.455794E+09 | 9495238.08 |
| April | 0.219778E+09 | 83994199.05 | 0.135784E+09 | 0.465325E+09 | 2290712.32 |
| May | 0.195118E+09 | 59006733.03 | 0.136111E+09 | 0.431027E+09 | 4779721.41 |
| June | 0.201254E+09 | 66322556.51 | 0.134932E+09 | 0.435906E+09 | 4906784.46 |
| July | 0.177696E+09 | 39900904.34 | 0.137795E+09 | 0.362031E+09 | 11584186.25 |
| August | 0.195337E+09 | 57353203.69 | 0.137983E+09 | 0.389899E+09 | 8044529.22 |
| September | 0.177722E+09 | 48504115.16 | 0.129218E+09 | 0.364900E+09 | 7833916.70 |
| October | 0.172288E+09 | 44232434.88 | 0.128055E+09 | 0.335725E+09 | 12038720.33 |
| November | 0.161498E+09 | 44772595.62 | 0.116725E+09 | 0.313940E+09 | 17256582.02 |
| December | 0.170452E+09 | 54746880.90 | 0.115705E+09 | 0.324959E+09 | 34857640.21 |
| Annual Sum or Average | 0.226376E+10 | 0.716129E+09 | 0.154763E+10 | 0.459529E+10 | 0.158696E+09 |
| Minimum of Months | 0.161498E+09 | 39900904.34 | 0.115705E+09 | 0.313940E+09 | 2290712.32 |
| Maximum of Months | 0.224817E+09 | 87874007.30 | 0.137983E+09 | 0.465325E+09 | 34857640.21 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.182168E+09 | 61675549.49 | 0.120493E+09 | 0.355163E+09 | 27603172.92 |
| February | 0.185635E+09 | 67745811.95 | 0.117889E+09 | 0.370776E+09 | 16286470.42 |
| March | 0.224817E+09 | 87874007.30 | 0.136943E+09 | 0.457958E+09 | 9214124.31 |
| April | 0.219778E+09 | 83994199.05 | 0.135784E+09 | 0.464963E+09 | 2288857.64 |
| May | 0.195118E+09 | 59006733.03 | 0.136111E+09 | 0.429078E+09 | 4901662.27 |
| June | 0.201254E+09 | 66322556.51 | 0.134932E+09 | 0.432529E+09 | 5103514.88 |
| July | 0.177696E+09 | 39900904.34 | 0.137795E+09 | 0.360161E+09 | 11902640.30 |
| August | 0.195337E+09 | 57353203.69 | 0.137983E+09 | 0.388854E+09 | 8160565.10 |
| September | 0.177722E+09 | 48504115.16 | 0.129218E+09 | 0.365451E+09 | 7793253.13 |
| October | 0.172288E+09 | 44232434.88 | 0.128055E+09 | 0.337917E+09 | 11706829.38 |
| November | 0.161498E+09 | 44772595.62 | 0.116725E+09 | 0.318055E+09 | 16614882.41 |
| December | 0.170452E+09 | 54746880.90 | 0.115705E+09 | 0.330663E+09 | 33666219.24 |
| Annual Sum or Average | 0.226376E+10 | 0.716129E+09 | 0.154763E+10 | 0.461157E+10 | 0.155242E+09 |
| Minimum of Months | 0.161498E+09 | 39900904.34 | 0.115705E+09 | 0.318055E+09 | 2288857.64 |
| Maximum of Months | 0.224817E+09 | 87874007.30 | 0.137983E+09 | 0.464963E+09 | 33666219.24 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.296989E+09 | 45451179.60 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.300286E+09 | 27817893.35 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.360152E+09 | 16935370.51 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.404351E+09 | 3683732.97 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.531000E+09 | 7481158.80 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.603090E+09 | 7790939.59 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.490299E+09 | 18219536.42 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.409549E+09 | 12597725.39 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.347757E+09 | 11990665.92 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.321020E+09 | 17793864.21 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.295233E+09 | 25562345.99 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.285448E+09 | 53642302.67 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.464517E+10 | 0.248967E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.285448E+09 | 3683732.97 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.603090E+09 | 53642302.67 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.303746E+09 | 45188460.09 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.307430E+09 | 27312076.18 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.369056E+09 | 16423627.11 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.414036E+09 | 3555180.94 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.539806E+09 | 7241038.45 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.611874E+09 | 7548982.91 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.497372E+09 | 17718506.04 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.417229E+09 | 12265796.39 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.355180E+09 | 11588911.84 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.327537E+09 | 17370652.27 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.301467E+09 | 25241705.85 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.291649E+09 | 53575853.00 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.473638E+10 | 0.245031E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.291649E+09 | 3555180.94 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.611874E+09 | 53575853.00 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.303704E+09 | 45148795.09 |
| February | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.307393E+09 | 27283660.06 |
| March | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.369038E+09 | 16392340.97 |
| April | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.414029E+09 | 3549337.03 |
| May | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.539788E+09 | 7233182.22 |
| June | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.611852E+09 | 7540547.54 |
| July | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.497342E+09 | 17700139.41 |
| August | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.417195E+09 | 12249886.54 |
| September | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.355152E+09 | 11576368.91 |
| October | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.327512E+09 | 17352143.17 |
| November | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.301441E+09 | 25221894.09 |
| December | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.291608E+09 | 53540804.49 |
| Annual Sum or Average | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.473606E+10 | 0.244789E+09 |
| Minimum of Months | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.291608E+09 | 3549337.03 |
| Maximum of Months | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.611852E+09 | 53540804.49 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.742920E+09 | 43865022.23 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.620822E+09 | 25949299.32 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.514098E+09 | 14458688.51 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.406736E+09 | 3477862.05 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.425218E+09 | 6823927.78 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.405887E+09 | 7120956.50 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.372469E+09 | 16741774.25 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.361962E+09 | 11045102.62 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.394762E+09 | 11618179.68 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.488023E+09 | 18320257.85 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.605124E+09 | 26471770.68 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.734244E+09 | 53727418.40 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.607227E+10 | 0.239620E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.361962E+09 | 3477862.05 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.742920E+09 | 53727418.40 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.742886E+09 | 43827488.82 |
| February | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.620793E+09 | 25923235.25 |
| March | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.514086E+09 | 14429400.77 |
| April | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.406732E+09 | 3472808.89 |
| May | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.425201E+09 | 6816663.13 |
| June | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.405864E+09 | 7112770.87 |
| July | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.372440E+09 | 16723197.40 |
| August | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.361927E+09 | 11029610.72 |
| September | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.394734E+09 | 11605351.81 |
| October | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.488000E+09 | 18301497.79 |
| November | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.605103E+09 | 26452764.40 |
| December | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.734210E+09 | 53693671.16 |
| Annual Sum or Average | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.607198E+10 | 0.239388E+09 |
| Minimum of Months | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.361927E+09 | 3472808.89 |
| Maximum of Months | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.742886E+09 | 53693671.16 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 43712024.36 | 14799299.15 | 28912725.21 | 79313066.26 | 11236909.48 |
| February | 44543766.57 | 16255883.33 | 28287883.24 | 83307081.41 | 7709394.12 |
| March | 53945710.55 | 21085725.73 | 32859984.82 | 0.102799E+09 | 5961940.71 |
| April | 52736661.19 | 20154749.95 | 32581911.24 | 0.102822E+09 | 2317766.85 |
| May | 46819388.08 | 14158905.77 | 32660482.31 | 94442413.82 | 3489917.48 |
| June | 48291756.52 | 15914367.39 | 32377389.13 | 96103235.07 | 3653292.79 |
| July | 42638762.10 | 9574384.41 | 33064377.69 | 80301342.63 | 6595196.19 |
| August | 46871789.94 | 13762134.68 | 33109655.27 | 86919904.71 | 5706611.22 |
| September | 42645162.77 | 11638759.86 | 31006402.91 | 81153132.51 | 5354258.63 |
| October | 41341127.91 | 10613752.79 | 30727375.12 | 74801716.38 | 7170678.90 |
| November | 38751984.03 | 10743366.56 | 28008617.47 | 70406162.19 | 8164325.82 |
| December | 40900727.06 | 13136736.91 | 27763990.15 | 73846974.14 | 12946801.53 |
| Annual Sum or Average | 0.543199E+09 | 0.171838E+09 | 0.371361E+09 | 0.102622E+10 | 80307093.74 |
| Minimum of Months | 38751984.03 | 9574384.41 | 27763990.15 | 70406162.19 | 2317766.85 |
| Maximum of Months | 53945710.55 | 21085725.73 | 33109655.27 | 0.102822E+09 | 12946801.53 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.130185E+09 | 44075995.86 | 86109291.01 | 0.231285E+09 | 40830469.08 |
| February | 0.132662E+09 | 48414066.05 | 84248356.10 | 0.242385E+09 | 30485792.74 |
| March | 0.160664E+09 | 62798538.70 | 97865212.43 | 0.299294E+09 | 26030281.70 |
| April | 0.157063E+09 | 60025861.14 | 97037040.12 | 0.297752E+09 | 13457835.69 |
| May | 0.139440E+09 | 42168745.02 | 97271044.32 | 0.271067E+09 | 15842060.67 |
| June | 0.143825E+09 | 47396946.60 | 96427922.36 | 0.277526E+09 | 16822278.99 |
| July | 0.126989E+09 | 28514899.48 | 98473945.26 | 0.232910E+09 | 25721491.84 |
| August | 0.139596E+09 | 40987061.95 | 98608793.17 | 0.251942E+09 | 23560459.30 |
| September | 0.127008E+09 | 34663123.33 | 92344784.22 | 0.235439E+09 | 21922790.16 |
| October | 0.123124E+09 | 31610397.19 | 91513770.02 | 0.217497E+09 | 27784414.56 |
| November | 0.115413E+09 | 31996419.25 | 83416633.15 | 0.205039E+09 | 30789656.06 |
| December | 0.121813E+09 | 39124471.78 | 82688072.10 | 0.215341E+09 | 45586171.84 |
| Annual Sum or Average | 0.161778E+10 | 0.511777E+09 | 0.110600E+10 | 0.297748E+10 | 0.318834E+09 |
| Minimum of Months | 0.115413E+09 | 28514899.48 | 82688072.10 | 0.205039E+09 | 13457835.69 |
| Maximum of Months | 0.160664E+09 | 62798538.70 | 98608793.17 | 0.299294E+09 | 45586171.84 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 43712024.36 | 14799299.15 | 28912725.21 | 80634188.63 | 11137879.70 |
| February | 44543766.57 | 16255883.33 | 28287883.24 | 84804431.35 | 7678985.58 |
| March | 53945710.55 | 21085725.73 | 32859984.82 | 0.104926E+09 | 5754950.30 |
| April | 52736661.19 | 20154749.95 | 32581911.24 | 0.105555E+09 | 2229001.52 |
| May | 46819388.08 | 14158905.77 | 32660482.31 | 97190540.77 | 3241578.70 |
| June | 48291756.52 | 15914367.39 | 32377389.13 | 98738190.87 | 3344461.44 |
| July | 42638762.10 | 9574384.41 | 33064377.69 | 82232553.10 | 6279288.36 |
| August | 46871789.94 | 13762134.68 | 33109655.27 | 88727569.49 | 5365331.14 |
| September | 42645162.77 | 11638759.86 | 31006402.91 | 83110282.18 | 5014193.56 |
| October | 41341127.91 | 10613752.79 | 30727375.12 | 76432341.99 | 6845013.48 |
| November | 38751984.03 | 10743366.56 | 28008617.47 | 71862376.72 | 7959103.58 |
| December | 40900727.06 | 13136736.91 | 27763990.15 | 74996577.65 | 12881330.49 |
| Annual Sum or Average | 0.543199E+09 | 0.171838E+09 | 0.371361E+09 | 0.104921E+10 | 77731117.85 |
| Minimum of Months | 38751984.03 | 9574384.41 | 27763990.15 | 71862376.72 | 2229001.52 |
| Maximum of Months | 53945710.55 | 21085725.73 | 33109655.27 | 0.105555E+09 | 12881330.49 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 414.84 | 31.59 | 209.30 | 82.17 | 127.13 | 0.00 | 0.00 |
| February | 410.52 | 22.43 | 196.86 | 67.02 | 129.83 | 0.00 | 0.00 |
| March | 366.83 | 12.69 | 167.06 | 44.83 | 122.22 | 0.00 | 0.00 |
| April | 335.98 | 3.14 | 146.92 | 33.13 | 113.80 | 0.00 | 0.00 |
| May | 318.68 | 5.57 | 133.60 | 21.44 | 112.16 | 0.00 | 0.00 |
| June | 325.97 | 5.88 | 139.39 | 26.99 | 112.40 | 0.00 | 0.00 |
| July | 277.13 | 13.27 | 129.74 | 15.79 | 113.95 | 0.00 | 0.00 |
| August | 280.52 | 9.36 | 133.89 | 21.61 | 112.28 | 0.00 | 0.00 |
| September | 293.18 | 9.75 | 135.45 | 20.68 | 114.76 | 0.00 | 0.00 |
| October | 309.59 | 14.06 | 152.00 | 30.04 | 121.97 | 0.00 | 0.00 |
| November | 358.20 | 20.21 | 178.68 | 53.23 | 125.45 | 0.00 | 0.00 |
| December | 401.04 | 37.42 | 204.97 | 80.70 | 124.27 | 0.00 | 0.00 |
| Annual Sum or Average | 340.61 | 15.45 | 160.47 | 41.35 | 119.13 | 0.00 | 0.00 |
| Minimum of Months | 277.13 | 3.14 | 129.74 | 15.79 | 112.16 | 0.00 | 0.00 |
| Maximum of Months | 414.84 | 37.42 | 209.30 | 82.17 | 129.83 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 251.25 | 31.52 | 122.42 | 24.34 | 98.08 | 0.00 | 0.00 |
| February | 281.34 | 22.42 | 132.57 | 26.73 | 105.85 | 0.00 | 0.00 |
| March | 312.95 | 13.06 | 143.30 | 33.50 | 109.81 | 0.00 | 0.00 |
| April | 339.24 | 3.26 | 149.50 | 33.69 | 115.81 | 0.00 | 0.00 |
| May | 361.68 | 5.89 | 154.30 | 30.38 | 123.92 | 0.00 | 0.00 |
| June | 405.55 | 6.26 | 177.87 | 46.86 | 131.01 | 0.00 | 0.00 |
| July | 323.87 | 13.88 | 152.42 | 24.50 | 127.92 | 0.00 | 0.00 |
| August | 301.21 | 9.87 | 143.96 | 25.07 | 118.88 | 0.00 | 0.00 |
| September | 277.84 | 9.72 | 128.28 | 18.91 | 109.38 | 0.00 | 0.00 |
| October | 249.52 | 13.45 | 121.91 | 16.48 | 105.43 | 0.00 | 0.00 |
| November | 241.15 | 19.27 | 117.12 | 16.92 | 100.19 | 0.00 | 0.00 |
| December | 236.18 | 36.92 | 115.82 | 20.91 | 94.91 | 0.00 | 0.00 |
| Annual Sum or Average | 298.43 | 15.47 | 138.28 | 26.49 | 111.79 | 0.00 | 0.00 |
| Minimum of Months | 236.18 | 3.26 | 115.82 | 16.48 | 94.91 | 0.00 | 0.00 |
| Maximum of Months | 405.55 | 36.92 | 177.87 | 46.86 | 131.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 379.47 | 74.64 | 208.38 | 80.85 | 127.53 | 0.00 | 0.00 |
| February | 378.57 | 64.12 | 198.07 | 68.30 | 129.77 | 0.00 | 0.00 |
| March | 332.03 | 51.94 | 166.30 | 44.15 | 122.14 | 0.00 | 0.00 |
| April | 290.68 | 35.08 | 146.76 | 33.06 | 113.70 | 0.00 | 0.00 |
| May | 272.93 | 36.01 | 134.07 | 22.03 | 112.04 | 0.00 | 0.00 |
| June | 281.46 | 37.73 | 138.65 | 25.59 | 113.06 | 0.00 | 0.00 |
| July | 238.63 | 51.21 | 129.19 | 14.90 | 114.29 | 0.00 | 0.00 |
| August | 248.17 | 47.19 | 134.05 | 21.45 | 112.60 | 0.00 | 0.00 |
| September | 258.08 | 47.54 | 135.98 | 20.57 | 115.41 | 0.00 | 0.00 |
| October | 277.35 | 56.01 | 152.38 | 30.07 | 122.30 | 0.00 | 0.00 |
| November | 325.77 | 61.24 | 178.71 | 53.58 | 125.13 | 0.00 | 0.00 |
| December | 369.87 | 79.27 | 204.75 | 80.23 | 124.53 | 0.00 | 0.00 |
| Annual Sum or Average | 303.98 | 53.50 | 160.42 | 41.10 | 119.32 | 0.00 | 0.00 |
| Minimum of Months | 238.63 | 35.08 | 129.19 | 14.90 | 112.04 | 0.00 | 0.00 |
| Maximum of Months | 379.47 | 79.27 | 208.38 | 80.85 | 129.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 247.46 | 29.46 | 121.50 | 23.03 | 98.47 | 0.00 | 0.00 |
| February | 282.14 | 20.90 | 133.79 | 28.00 | 105.79 | 0.00 | 0.00 |
| March | 311.14 | 12.00 | 142.54 | 32.82 | 109.72 | 0.00 | 0.00 |
| April | 340.58 | 3.12 | 149.34 | 33.62 | 115.72 | 0.00 | 0.00 |
| May | 363.61 | 5.89 | 154.78 | 30.97 | 123.80 | 0.00 | 0.00 |
| June | 405.05 | 6.30 | 177.13 | 45.46 | 131.68 | 0.00 | 0.00 |
| July | 322.99 | 13.87 | 151.87 | 23.60 | 128.26 | 0.00 | 0.00 |
| August | 302.32 | 9.98 | 144.11 | 24.91 | 119.20 | 0.00 | 0.00 |
| September | 279.61 | 9.65 | 128.82 | 18.80 | 110.02 | 0.00 | 0.00 |
| October | 250.58 | 13.24 | 122.28 | 16.51 | 105.77 | 0.00 | 0.00 |
| November | 241.00 | 18.76 | 117.14 | 17.27 | 99.87 | 0.00 | 0.00 |
| December | 233.59 | 35.11 | 115.60 | 20.44 | 95.16 | 0.00 | 0.00 |
| Annual Sum or Average | 298.27 | 14.87 | 138.23 | 26.24 | 111.98 | 0.00 | 0.00 |
| Minimum of Months | 233.59 | 3.12 | 115.60 | 16.51 | 95.16 | 0.00 | 0.00 |
| Maximum of Months | 405.05 | 35.11 | 177.13 | 45.46 | 131.68 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 115.72 | 18.19 | 53.49 | 0.00 | 53.49 | 0.00 | 0.00 |
| February | 129.59 | 12.67 | 57.06 | 0.00 | 57.06 | 0.00 | 0.00 |
| March | 140.51 | 7.07 | 58.61 | 0.01 | 58.59 | 0.00 | 0.00 |
| April | 162.46 | 1.71 | 64.55 | 1.22 | 63.33 | 0.00 | 0.00 |
| May | 204.43 | 3.21 | 81.93 | 8.94 | 72.99 | 0.00 | 0.00 |
| June | 239.24 | 3.43 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
| July | 188.79 | 7.68 | 85.52 | 8.71 | 76.82 | 0.00 | 0.00 |
| August | 158.04 | 5.48 | 71.18 | 3.50 | 67.69 | 0.00 | 0.00 |
| September | 139.40 | 5.24 | 60.25 | 0.08 | 60.17 | 0.00 | 0.00 |
| October | 124.58 | 7.38 | 57.96 | 0.00 | 57.96 | 0.00 | 0.00 |
| November | 118.58 | 10.90 | 54.84 | 0.00 | 54.84 | 0.00 | 0.00 |
| December | 110.99 | 21.47 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Annual Sum or Average | 152.75 | 8.71 | 66.44 | 3.54 | 62.91 | 0.00 | 0.00 |
| Minimum of Months | 110.99 | 1.71 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Maximum of Months | 239.24 | 21.47 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 115.72 | 18.19 | 53.49 | 0.00 | 53.49 | 0.00 | 0.00 |
| February | 129.59 | 12.66 | 57.06 | 0.00 | 57.06 | 0.00 | 0.00 |
| March | 140.51 | 7.07 | 58.61 | 0.01 | 58.59 | 0.00 | 0.00 |
| April | 162.46 | 1.71 | 64.55 | 1.22 | 63.33 | 0.00 | 0.00 |
| May | 204.42 | 3.21 | 81.93 | 8.94 | 72.99 | 0.00 | 0.00 |
| June | 239.23 | 3.43 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
| July | 188.79 | 7.68 | 85.52 | 8.71 | 76.82 | 0.00 | 0.00 |
| August | 158.03 | 5.48 | 71.18 | 3.50 | 67.69 | 0.00 | 0.00 |
| September | 139.40 | 5.24 | 60.25 | 0.08 | 60.17 | 0.00 | 0.00 |
| October | 124.58 | 7.38 | 57.96 | 0.00 | 57.96 | 0.00 | 0.00 |
| November | 118.58 | 10.89 | 54.84 | 0.00 | 54.84 | 0.00 | 0.00 |
| December | 110.98 | 21.47 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Annual Sum or Average | 152.75 | 8.71 | 66.44 | 3.54 | 62.91 | 0.00 | 0.00 |
| Minimum of Months | 110.98 | 1.71 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Maximum of Months | 239.23 | 21.47 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 281.17 | 18.14 | 140.36 | 57.82 | 82.54 | 0.00 | 0.00 |
| February | 260.27 | 12.55 | 121.34 | 40.29 | 81.04 | 0.00 | 0.00 |
| March | 195.05 | 6.65 | 82.36 | 11.35 | 71.01 | 0.00 | 0.00 |
| April | 159.15 | 1.66 | 61.97 | 0.66 | 61.31 | 0.00 | 0.00 |
| May | 160.86 | 3.00 | 61.23 | 0.00 | 61.23 | 0.00 | 0.00 |
| June | 158.65 | 3.17 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| July | 141.46 | 7.25 | 62.84 | 0.00 | 62.84 | 0.00 | 0.00 |
| August | 137.05 | 5.06 | 61.12 | 0.04 | 61.09 | 0.00 | 0.00 |
| September | 154.84 | 5.29 | 67.41 | 1.86 | 65.56 | 0.00 | 0.00 |
| October | 185.20 | 7.86 | 88.05 | 13.56 | 74.49 | 0.00 | 0.00 |
| November | 236.81 | 11.61 | 116.40 | 36.30 | 80.10 | 0.00 | 0.00 |
| December | 277.72 | 21.85 | 141.11 | 59.79 | 81.33 | 0.00 | 0.00 |
| Annual Sum or Average | 195.36 | 8.68 | 88.63 | 18.39 | 70.24 | 0.00 | 0.00 |
| Minimum of Months | 137.05 | 1.66 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| Maximum of Months | 281.17 | 21.85 | 141.11 | 59.79 | 82.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 280.17 | 18.97 | 140.36 | 57.82 | 82.54 | 0.00 | 0.00 |
| February | 259.21 | 13.33 | 121.34 | 40.29 | 81.04 | 0.00 | 0.00 |
| March | 193.85 | 7.26 | 82.36 | 11.35 | 71.01 | 0.00 | 0.00 |
| April | 157.46 | 1.88 | 61.97 | 0.66 | 61.31 | 0.00 | 0.00 |
| May | 159.28 | 3.34 | 61.23 | 0.00 | 61.23 | 0.00 | 0.00 |
| June | 157.12 | 3.52 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| July | 140.28 | 7.94 | 62.84 | 0.00 | 62.84 | 0.00 | 0.00 |
| August | 135.77 | 5.61 | 61.12 | 0.04 | 61.09 | 0.00 | 0.00 |
| September | 153.58 | 5.87 | 67.41 | 1.86 | 65.56 | 0.00 | 0.00 |
| October | 184.10 | 8.64 | 88.05 | 13.56 | 74.49 | 0.00 | 0.00 |
| November | 235.78 | 12.38 | 116.40 | 36.30 | 80.10 | 0.00 | 0.00 |
| December | 276.82 | 22.65 | 141.11 | 59.79 | 81.33 | 0.00 | 0.00 |
| Annual Sum or Average | 194.12 | 9.29 | 88.63 | 18.39 | 70.24 | 0.00 | 0.00 |
| Minimum of Months | 135.77 | 1.88 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| Maximum of Months | 280.17 | 22.65 | 141.11 | 59.79 | 82.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 416.54 | 28.84 | 209.30 | 82.17 | 127.13 | 0.00 | 0.00 |
| February | 412.77 | 19.59 | 196.86 | 67.02 | 129.83 | 0.00 | 0.00 |
| March | 369.97 | 10.54 | 167.06 | 44.83 | 122.22 | 0.00 | 0.00 |
| April | 341.05 | 2.47 | 146.92 | 33.13 | 113.80 | 0.00 | 0.00 |
| May | 323.81 | 4.38 | 133.60 | 21.44 | 112.16 | 0.00 | 0.00 |
| June | 331.61 | 4.70 | 139.39 | 26.99 | 112.40 | 0.00 | 0.00 |
| July | 280.63 | 10.83 | 129.74 | 15.79 | 113.95 | 0.00 | 0.00 |
| August | 284.82 | 7.30 | 133.89 | 21.61 | 112.28 | 0.00 | 0.00 |
| September | 297.01 | 7.71 | 135.45 | 20.68 | 114.76 | 0.00 | 0.00 |
| October | 311.97 | 11.71 | 152.00 | 30.04 | 121.97 | 0.00 | 0.00 |
| November | 360.38 | 17.68 | 178.68 | 53.23 | 125.45 | 0.00 | 0.00 |
| December | 402.75 | 34.61 | 204.97 | 80.70 | 124.27 | 0.00 | 0.00 |
| Annual Sum or Average | 344.01 | 13.37 | 160.47 | 41.35 | 119.13 | 0.00 | 0.00 |
| Minimum of Months | 280.63 | 2.47 | 129.74 | 15.79 | 112.16 | 0.00 | 0.00 |
| Maximum of Months | 416.54 | 34.61 | 209.30 | 82.17 | 129.83 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 253.33 | 29.15 | 122.42 | 24.34 | 98.08 | 0.00 | 0.00 |
| February | 283.80 | 19.90 | 132.57 | 26.73 | 105.85 | 0.00 | 0.00 |
| March | 316.00 | 11.04 | 143.30 | 33.50 | 109.81 | 0.00 | 0.00 |
| April | 343.98 | 2.52 | 149.50 | 33.69 | 115.81 | 0.00 | 0.00 |
| May | 366.51 | 4.61 | 154.30 | 30.38 | 123.92 | 0.00 | 0.00 |
| June | 410.74 | 4.96 | 177.87 | 46.86 | 131.01 | 0.00 | 0.00 |
| July | 327.19 | 11.33 | 152.42 | 24.50 | 127.92 | 0.00 | 0.00 |
| August | 305.33 | 7.77 | 143.96 | 25.07 | 118.88 | 0.00 | 0.00 |
| September | 281.75 | 7.66 | 128.28 | 18.91 | 109.38 | 0.00 | 0.00 |
| October | 252.14 | 11.17 | 121.91 | 16.48 | 105.43 | 0.00 | 0.00 |
| November | 243.61 | 16.90 | 117.12 | 16.92 | 100.19 | 0.00 | 0.00 |
| December | 238.29 | 34.43 | 115.82 | 20.91 | 94.91 | 0.00 | 0.00 |
| Annual Sum or Average | 301.84 | 13.46 | 138.28 | 26.49 | 111.79 | 0.00 | 0.00 |
| Minimum of Months | 238.29 | 2.52 | 115.82 | 16.48 | 94.91 | 0.00 | 0.00 |
| Maximum of Months | 410.74 | 34.43 | 177.87 | 46.86 | 131.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 414.19 | 28.15 | 208.38 | 80.85 | 127.53 | 0.00 | 0.00 |
| February | 414.56 | 18.90 | 198.07 | 68.30 | 129.77 | 0.00 | 0.00 |
| March | 368.47 | 9.63 | 166.30 | 44.15 | 122.14 | 0.00 | 0.00 |
| April | 342.62 | 2.39 | 146.76 | 33.06 | 113.70 | 0.00 | 0.00 |
| May | 325.76 | 4.38 | 134.07 | 22.03 | 112.04 | 0.00 | 0.00 |
| June | 330.92 | 4.64 | 138.65 | 25.59 | 113.06 | 0.00 | 0.00 |
| July | 279.72 | 10.77 | 129.19 | 14.90 | 114.29 | 0.00 | 0.00 |
| August | 285.84 | 7.36 | 134.05 | 21.45 | 112.60 | 0.00 | 0.00 |
| September | 298.83 | 7.62 | 135.98 | 20.57 | 115.41 | 0.00 | 0.00 |
| October | 313.15 | 11.59 | 152.38 | 30.07 | 122.30 | 0.00 | 0.00 |
| November | 360.60 | 17.53 | 178.71 | 53.58 | 125.13 | 0.00 | 0.00 |
| December | 401.51 | 34.12 | 204.75 | 80.23 | 124.53 | 0.00 | 0.00 |
| Annual Sum or Average | 344.23 | 13.10 | 160.42 | 41.10 | 119.32 | 0.00 | 0.00 |
| Minimum of Months | 279.72 | 2.39 | 129.19 | 14.90 | 112.04 | 0.00 | 0.00 |
| Maximum of Months | 414.56 | 34.12 | 208.38 | 80.85 | 129.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 249.73 | 27.19 | 121.50 | 23.03 | 98.47 | 0.00 | 0.00 |
| February | 284.87 | 18.49 | 133.79 | 28.00 | 105.79 | 0.00 | 0.00 |
| March | 314.43 | 10.05 | 142.54 | 32.82 | 109.72 | 0.00 | 0.00 |
| April | 345.53 | 2.42 | 149.34 | 33.62 | 115.72 | 0.00 | 0.00 |
| May | 368.48 | 4.63 | 154.78 | 30.97 | 123.80 | 0.00 | 0.00 |
| June | 410.15 | 4.97 | 177.13 | 45.46 | 131.68 | 0.00 | 0.00 |
| July | 326.35 | 11.34 | 151.87 | 23.60 | 128.26 | 0.00 | 0.00 |
| August | 306.43 | 7.90 | 144.11 | 24.91 | 119.20 | 0.00 | 0.00 |
| September | 283.58 | 7.59 | 128.82 | 18.80 | 110.02 | 0.00 | 0.00 |
| October | 253.27 | 10.99 | 122.28 | 16.51 | 105.77 | 0.00 | 0.00 |
| November | 243.53 | 16.45 | 117.14 | 17.27 | 99.87 | 0.00 | 0.00 |
| December | 235.83 | 32.71 | 115.60 | 20.44 | 95.16 | 0.00 | 0.00 |
| Annual Sum or Average | 301.78 | 12.90 | 138.23 | 26.24 | 111.98 | 0.00 | 0.00 |
| Minimum of Months | 235.83 | 2.42 | 115.60 | 16.51 | 95.16 | 0.00 | 0.00 |
| Maximum of Months | 410.15 | 32.71 | 177.13 | 45.46 | 131.68 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 116.96 | 17.03 | 53.49 | 0.00 | 53.49 | 0.00 | 0.00 |
| February | 131.09 | 11.46 | 57.06 | 0.00 | 57.06 | 0.00 | 0.00 |
| March | 142.38 | 6.12 | 58.61 | 0.01 | 58.59 | 0.00 | 0.00 |
| April | 165.11 | 1.37 | 64.55 | 1.22 | 63.33 | 0.00 | 0.00 |
| May | 206.91 | 2.59 | 81.93 | 8.94 | 72.99 | 0.00 | 0.00 |
| June | 241.76 | 2.79 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
| July | 190.42 | 6.46 | 85.52 | 8.71 | 76.82 | 0.00 | 0.00 |
| August | 160.17 | 4.50 | 71.18 | 3.50 | 67.69 | 0.00 | 0.00 |
| September | 141.48 | 4.28 | 60.25 | 0.08 | 60.17 | 0.00 | 0.00 |
| October | 126.06 | 6.27 | 57.96 | 0.00 | 57.96 | 0.00 | 0.00 |
| November | 119.96 | 9.73 | 54.84 | 0.00 | 54.84 | 0.00 | 0.00 |
| December | 112.20 | 20.26 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Annual Sum or Average | 154.60 | 7.74 | 66.44 | 3.54 | 62.91 | 0.00 | 0.00 |
| Minimum of Months | 112.20 | 1.37 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Maximum of Months | 241.76 | 20.26 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 116.96 | 17.03 | 53.49 | 0.00 | 53.49 | 0.00 | 0.00 |
| February | 131.08 | 11.46 | 57.06 | 0.00 | 57.06 | 0.00 | 0.00 |
| March | 142.38 | 6.11 | 58.61 | 0.01 | 58.59 | 0.00 | 0.00 |
| April | 165.10 | 1.37 | 64.55 | 1.22 | 63.33 | 0.00 | 0.00 |
| May | 206.91 | 2.59 | 81.93 | 8.94 | 72.99 | 0.00 | 0.00 |
| June | 241.76 | 2.79 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
| July | 190.41 | 6.46 | 85.52 | 8.71 | 76.82 | 0.00 | 0.00 |
| August | 160.16 | 4.50 | 71.18 | 3.50 | 67.69 | 0.00 | 0.00 |
| September | 141.47 | 4.28 | 60.25 | 0.08 | 60.17 | 0.00 | 0.00 |
| October | 126.05 | 6.26 | 57.96 | 0.00 | 57.96 | 0.00 | 0.00 |
| November | 119.95 | 9.72 | 54.84 | 0.00 | 54.84 | 0.00 | 0.00 |
| December | 112.19 | 20.25 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Annual Sum or Average | 154.59 | 7.74 | 66.44 | 3.54 | 62.91 | 0.00 | 0.00 |
| Minimum of Months | 112.19 | 1.37 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Maximum of Months | 241.76 | 20.25 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 281.99 | 16.69 | 140.36 | 57.82 | 82.54 | 0.00 | 0.00 |
| February | 261.51 | 11.10 | 121.34 | 40.29 | 81.04 | 0.00 | 0.00 |
| March | 196.96 | 5.52 | 82.36 | 11.35 | 71.01 | 0.00 | 0.00 |
| April | 162.20 | 1.35 | 61.97 | 0.66 | 61.31 | 0.00 | 0.00 |
| May | 163.80 | 2.42 | 61.23 | 0.00 | 61.23 | 0.00 | 0.00 |
| June | 161.82 | 2.60 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| July | 143.40 | 6.07 | 62.84 | 0.00 | 62.84 | 0.00 | 0.00 |
| August | 139.45 | 4.06 | 61.12 | 0.04 | 61.09 | 0.00 | 0.00 |
| September | 156.91 | 4.31 | 67.41 | 1.86 | 65.56 | 0.00 | 0.00 |
| October | 186.45 | 6.67 | 88.05 | 13.56 | 74.49 | 0.00 | 0.00 |
| November | 237.87 | 10.31 | 116.40 | 36.30 | 80.10 | 0.00 | 0.00 |
| December | 278.48 | 20.40 | 141.11 | 59.79 | 81.33 | 0.00 | 0.00 |
| Annual Sum or Average | 197.24 | 7.63 | 88.63 | 18.39 | 70.24 | 0.00 | 0.00 |
| Minimum of Months | 139.45 | 1.35 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| Maximum of Months | 281.99 | 20.40 | 141.11 | 59.79 | 82.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 281.99 | 16.69 | 140.36 | 57.82 | 82.54 | 0.00 | 0.00 |
| February | 261.50 | 11.10 | 121.34 | 40.29 | 81.04 | 0.00 | 0.00 |
| March | 196.96 | 5.52 | 82.36 | 11.35 | 71.01 | 0.00 | 0.00 |
| April | 162.19 | 1.35 | 61.97 | 0.66 | 61.31 | 0.00 | 0.00 |
| May | 163.80 | 2.42 | 61.23 | 0.00 | 61.23 | 0.00 | 0.00 |
| June | 161.82 | 2.60 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| July | 143.39 | 6.07 | 62.84 | 0.00 | 62.84 | 0.00 | 0.00 |
| August | 139.44 | 4.06 | 61.12 | 0.04 | 61.09 | 0.00 | 0.00 |
| September | 156.90 | 4.30 | 67.41 | 1.86 | 65.56 | 0.00 | 0.00 |
| October | 186.45 | 6.67 | 88.05 | 13.56 | 74.49 | 0.00 | 0.00 |
| November | 237.87 | 10.31 | 116.40 | 36.30 | 80.10 | 0.00 | 0.00 |
| December | 278.47 | 20.39 | 141.11 | 59.79 | 81.33 | 0.00 | 0.00 |
| Annual Sum or Average | 197.24 | 7.63 | 88.63 | 18.39 | 70.24 | 0.00 | 0.00 |
| Minimum of Months | 139.44 | 1.35 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| Maximum of Months | 281.99 | 20.39 | 141.11 | 59.79 | 82.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 408.07 | 28.02 | 209.30 | 82.17 | 127.13 | 0.00 | 0.00 |
| February | 403.62 | 18.64 | 196.86 | 67.02 | 129.83 | 0.00 | 0.00 |
| March | 360.42 | 10.07 | 167.06 | 44.83 | 122.22 | 0.00 | 0.00 |
| April | 331.07 | 2.34 | 146.92 | 33.13 | 113.80 | 0.00 | 0.00 |
| May | 314.29 | 4.41 | 133.60 | 21.44 | 112.16 | 0.00 | 0.00 |
| June | 321.72 | 4.77 | 139.39 | 26.99 | 112.40 | 0.00 | 0.00 |
| July | 272.31 | 10.83 | 129.74 | 15.79 | 113.95 | 0.00 | 0.00 |
| August | 276.58 | 7.16 | 133.89 | 21.61 | 112.28 | 0.00 | 0.00 |
| September | 288.30 | 7.74 | 135.45 | 20.68 | 114.76 | 0.00 | 0.00 |
| October | 304.10 | 11.67 | 152.00 | 30.04 | 121.97 | 0.00 | 0.00 |
| November | 352.18 | 17.16 | 178.68 | 53.23 | 125.45 | 0.00 | 0.00 |
| December | 394.79 | 33.69 | 204.97 | 80.70 | 124.27 | 0.00 | 0.00 |
| Annual Sum or Average | 335.20 | 13.05 | 160.47 | 41.35 | 119.13 | 0.00 | 0.00 |
| Minimum of Months | 272.31 | 2.34 | 129.74 | 15.79 | 112.16 | 0.00 | 0.00 |
| Maximum of Months | 408.07 | 33.69 | 209.30 | 82.17 | 129.83 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 246.39 | 28.50 | 122.42 | 24.34 | 98.08 | 0.00 | 0.00 |
| February | 275.96 | 19.22 | 132.57 | 26.73 | 105.85 | 0.00 | 0.00 |
| March | 307.14 | 10.79 | 143.30 | 33.50 | 109.81 | 0.00 | 0.00 |
| April | 333.91 | 2.39 | 149.50 | 33.69 | 115.81 | 0.00 | 0.00 |
| May | 356.51 | 4.61 | 154.30 | 30.38 | 123.92 | 0.00 | 0.00 |
| June | 400.14 | 4.99 | 177.87 | 46.86 | 131.01 | 0.00 | 0.00 |
| July | 318.32 | 11.28 | 152.42 | 24.50 | 127.92 | 0.00 | 0.00 |
| August | 296.93 | 7.65 | 143.96 | 25.07 | 118.88 | 0.00 | 0.00 |
| September | 273.27 | 7.71 | 128.28 | 18.91 | 109.38 | 0.00 | 0.00 |
| October | 244.95 | 11.22 | 121.91 | 16.48 | 105.43 | 0.00 | 0.00 |
| November | 236.55 | 16.54 | 117.12 | 16.92 | 100.19 | 0.00 | 0.00 |
| December | 231.82 | 33.56 | 115.82 | 20.91 | 94.91 | 0.00 | 0.00 |
| Annual Sum or Average | 293.44 | 13.21 | 138.28 | 26.49 | 111.79 | 0.00 | 0.00 |
| Minimum of Months | 231.82 | 2.39 | 115.82 | 16.48 | 94.91 | 0.00 | 0.00 |
| Maximum of Months | 400.14 | 33.56 | 177.87 | 46.86 | 131.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 405.50 | 27.14 | 208.38 | 80.85 | 127.53 | 0.00 | 0.00 |
| February | 405.24 | 17.84 | 198.07 | 68.30 | 129.77 | 0.00 | 0.00 |
| March | 358.74 | 9.06 | 166.30 | 44.15 | 122.14 | 0.00 | 0.00 |
| April | 332.57 | 2.26 | 146.76 | 33.06 | 113.70 | 0.00 | 0.00 |
| May | 316.20 | 4.40 | 134.07 | 22.03 | 112.04 | 0.00 | 0.00 |
| June | 321.03 | 4.69 | 138.65 | 25.59 | 113.06 | 0.00 | 0.00 |
| July | 271.46 | 10.73 | 129.19 | 14.90 | 114.29 | 0.00 | 0.00 |
| August | 277.64 | 7.20 | 134.05 | 21.45 | 112.60 | 0.00 | 0.00 |
| September | 290.17 | 7.62 | 135.98 | 20.57 | 115.41 | 0.00 | 0.00 |
| October | 305.18 | 11.48 | 152.38 | 30.07 | 122.30 | 0.00 | 0.00 |
| November | 352.32 | 16.95 | 178.71 | 53.58 | 125.13 | 0.00 | 0.00 |
| December | 393.35 | 33.05 | 204.75 | 80.23 | 124.53 | 0.00 | 0.00 |
| Annual Sum or Average | 335.34 | 12.71 | 160.42 | 41.10 | 119.32 | 0.00 | 0.00 |
| Minimum of Months | 271.46 | 2.26 | 129.19 | 14.90 | 112.04 | 0.00 | 0.00 |
| Maximum of Months | 405.50 | 33.05 | 208.38 | 80.85 | 129.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 242.71 | 26.50 | 121.50 | 23.03 | 98.47 | 0.00 | 0.00 |
| February | 276.91 | 17.76 | 133.79 | 28.00 | 105.79 | 0.00 | 0.00 |
| March | 305.33 | 9.65 | 142.54 | 32.82 | 109.72 | 0.00 | 0.00 |
| April | 335.37 | 2.29 | 149.34 | 33.62 | 115.72 | 0.00 | 0.00 |
| May | 358.45 | 4.62 | 154.78 | 30.97 | 123.80 | 0.00 | 0.00 |
| June | 399.53 | 4.96 | 177.13 | 45.46 | 131.68 | 0.00 | 0.00 |
| July | 317.52 | 11.24 | 151.87 | 23.60 | 128.26 | 0.00 | 0.00 |
| August | 298.08 | 7.74 | 144.11 | 24.91 | 119.20 | 0.00 | 0.00 |
| September | 275.14 | 7.61 | 128.82 | 18.80 | 110.02 | 0.00 | 0.00 |
| October | 245.99 | 10.98 | 122.28 | 16.51 | 105.77 | 0.00 | 0.00 |
| November | 236.43 | 16.09 | 117.14 | 17.27 | 99.87 | 0.00 | 0.00 |
| December | 229.31 | 31.88 | 115.60 | 20.44 | 95.16 | 0.00 | 0.00 |
| Annual Sum or Average | 293.33 | 12.62 | 138.23 | 26.24 | 111.98 | 0.00 | 0.00 |
| Minimum of Months | 229.31 | 2.29 | 115.60 | 16.51 | 95.16 | 0.00 | 0.00 |
| Maximum of Months | 399.53 | 31.88 | 177.13 | 45.46 | 131.68 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 113.41 | 16.87 | 53.49 | 0.00 | 53.49 | 0.00 | 0.00 |
| February | 127.08 | 11.29 | 57.06 | 0.00 | 57.06 | 0.00 | 0.00 |
| March | 137.79 | 6.13 | 58.61 | 0.01 | 58.59 | 0.00 | 0.00 |
| April | 159.74 | 1.37 | 64.55 | 1.22 | 63.33 | 0.00 | 0.00 |
| May | 201.54 | 2.70 | 81.93 | 8.94 | 72.99 | 0.00 | 0.00 |
| June | 236.06 | 2.91 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
| July | 185.70 | 6.62 | 85.52 | 8.71 | 76.82 | 0.00 | 0.00 |
| August | 155.78 | 4.58 | 71.18 | 3.50 | 67.69 | 0.00 | 0.00 |
| September | 137.03 | 4.47 | 60.25 | 0.08 | 60.17 | 0.00 | 0.00 |
| October | 122.29 | 6.49 | 57.96 | 0.00 | 57.96 | 0.00 | 0.00 |
| November | 116.31 | 9.74 | 54.84 | 0.00 | 54.84 | 0.00 | 0.00 |
| December | 108.89 | 20.00 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Annual Sum or Average | 150.19 | 7.77 | 66.44 | 3.54 | 62.91 | 0.00 | 0.00 |
| Minimum of Months | 108.89 | 1.37 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Maximum of Months | 236.06 | 20.00 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 113.39 | 16.86 | 53.49 | 0.00 | 53.49 | 0.00 | 0.00 |
| February | 127.06 | 11.28 | 57.06 | 0.00 | 57.06 | 0.00 | 0.00 |
| March | 137.78 | 6.12 | 58.61 | 0.01 | 58.59 | 0.00 | 0.00 |
| April | 159.73 | 1.37 | 64.55 | 1.22 | 63.33 | 0.00 | 0.00 |
| May | 201.53 | 2.70 | 81.93 | 8.94 | 72.99 | 0.00 | 0.00 |
| June | 236.05 | 2.91 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
| July | 185.69 | 6.61 | 85.52 | 8.71 | 76.82 | 0.00 | 0.00 |
| August | 155.76 | 4.57 | 71.18 | 3.50 | 67.69 | 0.00 | 0.00 |
| September | 137.02 | 4.47 | 60.25 | 0.08 | 60.17 | 0.00 | 0.00 |
| October | 122.28 | 6.48 | 57.96 | 0.00 | 57.96 | 0.00 | 0.00 |
| November | 116.30 | 9.73 | 54.84 | 0.00 | 54.84 | 0.00 | 0.00 |
| December | 108.87 | 19.99 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Annual Sum or Average | 150.18 | 7.76 | 66.44 | 3.54 | 62.91 | 0.00 | 0.00 |
| Minimum of Months | 108.87 | 1.37 | 51.96 | 0.00 | 51.96 | 0.00 | 0.00 |
| Maximum of Months | 236.05 | 19.99 | 99.49 | 19.87 | 79.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 277.37 | 16.38 | 140.36 | 57.82 | 82.54 | 0.00 | 0.00 |
| February | 256.62 | 10.73 | 121.34 | 40.29 | 81.04 | 0.00 | 0.00 |
| March | 191.94 | 5.40 | 82.36 | 11.35 | 71.01 | 0.00 | 0.00 |
| April | 156.92 | 1.34 | 61.97 | 0.66 | 61.31 | 0.00 | 0.00 |
| May | 158.76 | 2.55 | 61.23 | 0.00 | 61.23 | 0.00 | 0.00 |
| June | 156.59 | 2.75 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| July | 139.06 | 6.25 | 62.84 | 0.00 | 62.84 | 0.00 | 0.00 |
| August | 135.14 | 4.12 | 61.12 | 0.04 | 61.09 | 0.00 | 0.00 |
| September | 152.30 | 4.48 | 67.41 | 1.86 | 65.56 | 0.00 | 0.00 |
| October | 182.21 | 6.84 | 88.05 | 13.56 | 74.49 | 0.00 | 0.00 |
| November | 233.46 | 10.21 | 116.40 | 36.30 | 80.10 | 0.00 | 0.00 |
| December | 274.14 | 20.06 | 141.11 | 59.79 | 81.33 | 0.00 | 0.00 |
| Annual Sum or Average | 192.55 | 7.60 | 88.63 | 18.39 | 70.24 | 0.00 | 0.00 |
| Minimum of Months | 135.14 | 1.34 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| Maximum of Months | 277.37 | 20.06 | 141.11 | 59.79 | 82.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 277.36 | 16.36 | 140.36 | 57.82 | 82.54 | 0.00 | 0.00 |
| February | 256.61 | 10.72 | 121.34 | 40.29 | 81.04 | 0.00 | 0.00 |
| March | 191.94 | 5.39 | 82.36 | 11.35 | 71.01 | 0.00 | 0.00 |
| April | 156.92 | 1.34 | 61.97 | 0.66 | 61.31 | 0.00 | 0.00 |
| May | 158.75 | 2.55 | 61.23 | 0.00 | 61.23 | 0.00 | 0.00 |
| June | 156.58 | 2.74 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| July | 139.05 | 6.24 | 62.84 | 0.00 | 62.84 | 0.00 | 0.00 |
| August | 135.13 | 4.12 | 61.12 | 0.04 | 61.09 | 0.00 | 0.00 |
| September | 152.29 | 4.48 | 67.41 | 1.86 | 65.56 | 0.00 | 0.00 |
| October | 182.20 | 6.83 | 88.05 | 13.56 | 74.49 | 0.00 | 0.00 |
| November | 233.45 | 10.21 | 116.40 | 36.30 | 80.10 | 0.00 | 0.00 |
| December | 274.12 | 20.05 | 141.11 | 59.79 | 81.33 | 0.00 | 0.00 |
| Annual Sum or Average | 192.54 | 7.59 | 88.63 | 18.39 | 70.24 | 0.00 | 0.00 |
| Minimum of Months | 135.13 | 1.34 | 61.01 | 0.00 | 61.01 | 0.00 | 0.00 |
| Maximum of Months | 277.36 | 20.05 | 141.11 | 59.79 | 82.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 29.61 | 4.20 | 16.32 | 5.53 | 10.79 | 0.00 | 0.00 |
| February | 34.44 | 3.19 | 18.41 | 6.72 | 11.69 | 0.00 | 0.00 |
| March | 38.38 | 2.23 | 20.14 | 7.87 | 12.27 | 0.00 | 0.00 |
| April | 39.67 | 0.89 | 20.35 | 7.78 | 12.57 | 0.00 | 0.00 |
| May | 35.26 | 1.30 | 17.48 | 5.29 | 12.19 | 0.00 | 0.00 |
| June | 37.08 | 1.41 | 18.63 | 6.14 | 12.49 | 0.00 | 0.00 |
| July | 29.98 | 2.46 | 15.92 | 3.57 | 12.34 | 0.00 | 0.00 |
| August | 32.45 | 2.13 | 17.50 | 5.14 | 12.36 | 0.00 | 0.00 |
| September | 31.31 | 2.07 | 16.45 | 4.49 | 11.96 | 0.00 | 0.00 |
| October | 27.93 | 2.68 | 15.44 | 3.96 | 11.47 | 0.00 | 0.00 |
| November | 27.16 | 3.15 | 14.95 | 4.14 | 10.81 | 0.00 | 0.00 |
| December | 27.57 | 4.83 | 15.27 | 4.90 | 10.37 | 0.00 | 0.00 |
| Annual Sum or Average | 32.54 | 2.55 | 17.22 | 5.45 | 11.78 | 0.00 | 0.00 |
| Minimum of Months | 27.16 | 0.89 | 14.95 | 3.57 | 10.37 | 0.00 | 0.00 |
| Maximum of Months | 39.67 | 4.83 | 20.35 | 7.87 | 12.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 86.35 | 15.24 | 48.61 | 16.46 | 32.15 | 0.00 | 0.00 |
| February | 100.19 | 12.60 | 54.84 | 20.01 | 34.82 | 0.00 | 0.00 |
| March | 111.74 | 9.72 | 59.98 | 23.45 | 36.54 | 0.00 | 0.00 |
| April | 114.87 | 5.19 | 60.60 | 23.16 | 37.44 | 0.00 | 0.00 |
| May | 101.20 | 5.91 | 52.06 | 15.74 | 36.32 | 0.00 | 0.00 |
| June | 107.07 | 6.49 | 55.49 | 18.29 | 37.20 | 0.00 | 0.00 |
| July | 86.96 | 9.60 | 47.41 | 10.65 | 36.77 | 0.00 | 0.00 |
| August | 94.06 | 8.80 | 52.12 | 15.30 | 36.82 | 0.00 | 0.00 |
| September | 90.83 | 8.46 | 49.00 | 13.37 | 35.63 | 0.00 | 0.00 |
| October | 81.20 | 10.37 | 45.97 | 11.80 | 34.17 | 0.00 | 0.00 |
| November | 79.10 | 11.88 | 44.53 | 12.34 | 32.18 | 0.00 | 0.00 |
| December | 80.40 | 17.02 | 45.48 | 14.61 | 30.87 | 0.00 | 0.00 |
| Annual Sum or Average | 94.42 | 10.11 | 51.30 | 16.23 | 35.07 | 0.00 | 0.00 |
| Minimum of Months | 79.10 | 5.19 | 44.53 | 10.65 | 30.87 | 0.00 | 0.00 |
| Maximum of Months | 114.87 | 17.02 | 60.60 | 23.45 | 37.44 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 30.11 | 4.16 | 16.32 | 5.53 | 10.79 | 0.00 | 0.00 |
| February | 35.05 | 3.17 | 18.41 | 6.72 | 11.69 | 0.00 | 0.00 |
| March | 39.17 | 2.15 | 20.14 | 7.87 | 12.27 | 0.00 | 0.00 |
| April | 40.72 | 0.86 | 20.35 | 7.78 | 12.57 | 0.00 | 0.00 |
| May | 36.29 | 1.21 | 17.48 | 5.29 | 12.19 | 0.00 | 0.00 |
| June | 38.09 | 1.29 | 18.63 | 6.14 | 12.49 | 0.00 | 0.00 |
| July | 30.70 | 2.34 | 15.92 | 3.57 | 12.34 | 0.00 | 0.00 |
| August | 33.13 | 2.00 | 17.50 | 5.14 | 12.36 | 0.00 | 0.00 |
| September | 32.06 | 1.93 | 16.45 | 4.49 | 11.96 | 0.00 | 0.00 |
| October | 28.54 | 2.56 | 15.44 | 3.96 | 11.47 | 0.00 | 0.00 |
| November | 27.72 | 3.07 | 14.95 | 4.14 | 10.81 | 0.00 | 0.00 |
| December | 28.00 | 4.81 | 15.27 | 4.90 | 10.37 | 0.00 | 0.00 |
| Annual Sum or Average | 33.27 | 2.46 | 17.22 | 5.45 | 11.78 | 0.00 | 0.00 |
| Minimum of Months | 27.72 | 0.86 | 14.95 | 3.57 | 10.37 | 0.00 | 0.00 |
| Maximum of Months | 40.72 | 4.81 | 20.35 | 7.87 | 12.57 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.111112E+10 | 84621861.49 | 0.560585E+09 | 0.220080E+09 | 0.340504E+09 | 0.00 | 0.00 |
| February | 0.993125E+09 | 54260863.27 | 0.476232E+09 | 0.162140E+09 | 0.314092E+09 | 0.00 | 0.00 |
| March | 0.982524E+09 | 33993431.32 | 0.447440E+09 | 0.120074E+09 | 0.327366E+09 | 0.00 | 0.00 |
| April | 0.870862E+09 | 8136686.74 | 0.380824E+09 | 85867127.96 | 0.294957E+09 | 0.00 | 0.00 |
| May | 0.853546E+09 | 14920825.69 | 0.357824E+09 | 57412683.88 | 0.300411E+09 | 0.00 | 0.00 |
| June | 0.844913E+09 | 15243547.94 | 0.361303E+09 | 69965590.50 | 0.291338E+09 | 0.00 | 0.00 |
| July | 0.742252E+09 | 35529243.07 | 0.347506E+09 | 42298116.40 | 0.305208E+09 | 0.00 | 0.00 |
| August | 0.751342E+09 | 25058861.24 | 0.358624E+09 | 57893469.97 | 0.300731E+09 | 0.00 | 0.00 |
| September | 0.759910E+09 | 25280964.21 | 0.351075E+09 | 53606752.33 | 0.297468E+09 | 0.00 | 0.00 |
| October | 0.829219E+09 | 37660587.18 | 0.407128E+09 | 80454669.05 | 0.326673E+09 | 0.00 | 0.00 |
| November | 0.928462E+09 | 52384995.68 | 0.463137E+09 | 0.137965E+09 | 0.325172E+09 | 0.00 | 0.00 |
| December | 0.107414E+10 | 0.100228E+09 | 0.549003E+09 | 0.216149E+09 | 0.332854E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107414E+11 | 0.487319E+09 | 0.506068E+10 | 0.130391E+10 | 0.375678E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.742252E+09 | 8136686.74 | 0.347506E+09 | 42298116.40 | 0.291338E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.111112E+10 | 0.100228E+09 | 0.560585E+09 | 0.220080E+09 | 0.340504E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.672949E+09 | 84417542.82 | 0.327895E+09 | 65202191.82 | 0.262693E+09 | 0.00 | 0.00 |
| February | 0.680614E+09 | 54231956.63 | 0.320722E+09 | 64659888.95 | 0.256062E+09 | 0.00 | 0.00 |
| March | 0.838214E+09 | 34971088.32 | 0.383818E+09 | 89713399.09 | 0.294105E+09 | 0.00 | 0.00 |
| April | 0.879308E+09 | 8452294.07 | 0.387508E+09 | 87321178.15 | 0.300187E+09 | 0.00 | 0.00 |
| May | 0.968712E+09 | 15765874.83 | 0.413273E+09 | 81361494.92 | 0.331912E+09 | 0.00 | 0.00 |
| June | 0.105118E+10 | 16232789.28 | 0.461046E+09 | 0.121464E+09 | 0.339582E+09 | 0.00 | 0.00 |
| July | 0.867443E+09 | 37184241.87 | 0.408247E+09 | 65614104.39 | 0.342633E+09 | 0.00 | 0.00 |
| August | 0.806751E+09 | 26431876.92 | 0.385571E+09 | 67158033.69 | 0.318413E+09 | 0.00 | 0.00 |
| September | 0.720168E+09 | 25203280.75 | 0.332513E+09 | 49008147.86 | 0.283505E+09 | 0.00 | 0.00 |
| October | 0.668316E+09 | 36022442.82 | 0.326519E+09 | 44135038.74 | 0.282384E+09 | 0.00 | 0.00 |
| November | 0.625062E+09 | 49942102.20 | 0.303564E+09 | 43864372.98 | 0.259700E+09 | 0.00 | 0.00 |
| December | 0.632572E+09 | 98896395.98 | 0.310219E+09 | 56014806.47 | 0.254205E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.941129E+10 | 0.487752E+09 | 0.436089E+10 | 0.835516E+09 | 0.352538E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.625062E+09 | 8452294.07 | 0.303564E+09 | 43864372.98 | 0.254205E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.105118E+10 | 98896395.98 | 0.461046E+09 | 0.121464E+09 | 0.342633E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.101636E+10 | 0.199926E+09 | 0.558119E+09 | 0.216554E+09 | 0.341565E+09 | 0.00 | 0.00 |
| February | 0.915830E+09 | 0.155115E+09 | 0.479176E+09 | 0.165226E+09 | 0.313950E+09 | 0.00 | 0.00 |
| March | 0.889298E+09 | 0.139126E+09 | 0.445407E+09 | 0.118262E+09 | 0.327145E+09 | 0.00 | 0.00 |
| April | 0.753445E+09 | 90938136.31 | 0.380404E+09 | 85693325.38 | 0.294710E+09 | 0.00 | 0.00 |
| May | 0.731020E+09 | 96439342.45 | 0.359105E+09 | 59006733.03 | 0.300098E+09 | 0.00 | 0.00 |
| June | 0.729539E+09 | 97803400.79 | 0.359380E+09 | 66322556.51 | 0.293057E+09 | 0.00 | 0.00 |
| July | 0.639146E+09 | 0.137152E+09 | 0.346019E+09 | 39900904.34 | 0.306118E+09 | 0.00 | 0.00 |
| August | 0.664711E+09 | 0.126388E+09 | 0.359048E+09 | 57453784.56 | 0.301594E+09 | 0.00 | 0.00 |
| September | 0.668947E+09 | 0.123215E+09 | 0.352459E+09 | 53318184.99 | 0.299141E+09 | 0.00 | 0.00 |
| October | 0.742864E+09 | 0.150027E+09 | 0.408124E+09 | 80552065.18 | 0.327572E+09 | 0.00 | 0.00 |
| November | 0.844385E+09 | 0.158725E+09 | 0.463210E+09 | 0.138873E+09 | 0.324338E+09 | 0.00 | 0.00 |
| December | 0.990652E+09 | 0.212313E+09 | 0.548412E+09 | 0.214881E+09 | 0.333531E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.958619E+10 | 0.168717E+10 | 0.505886E+10 | 0.129604E+10 | 0.376282E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.639146E+09 | 90938136.31 | 0.346019E+09 | 39900904.34 | 0.293057E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.101636E+10 | 0.212313E+09 | 0.558119E+09 | 0.216554E+09 | 0.341565E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.662798E+09 | 78912470.67 | 0.325429E+09 | 61675549.49 | 0.263754E+09 | 0.00 | 0.00 |
| February | 0.682563E+09 | 50550226.30 | 0.323666E+09 | 67745811.95 | 0.255920E+09 | 0.00 | 0.00 |
| March | 0.833367E+09 | 32150825.55 | 0.381785E+09 | 87901725.16 | 0.293883E+09 | 0.00 | 0.00 |
| April | 0.882788E+09 | 8090370.36 | 0.387087E+09 | 87147375.57 | 0.299940E+09 | 0.00 | 0.00 |
| May | 0.973880E+09 | 15782474.49 | 0.414555E+09 | 82955544.07 | 0.331599E+09 | 0.00 | 0.00 |
| June | 0.104988E+10 | 16326048.73 | 0.459122E+09 | 0.117821E+09 | 0.341302E+09 | 0.00 | 0.00 |
| July | 0.865088E+09 | 37162776.35 | 0.406760E+09 | 63216892.33 | 0.343543E+09 | 0.00 | 0.00 |
| August | 0.809722E+09 | 26731599.81 | 0.385994E+09 | 66718348.27 | 0.319276E+09 | 0.00 | 0.00 |
| September | 0.724759E+09 | 25013904.22 | 0.333897E+09 | 48719580.52 | 0.285177E+09 | 0.00 | 0.00 |
| October | 0.671150E+09 | 35451745.31 | 0.327514E+09 | 44232434.88 | 0.283282E+09 | 0.00 | 0.00 |
| November | 0.624670E+09 | 48635218.44 | 0.303638E+09 | 44772595.62 | 0.258866E+09 | 0.00 | 0.00 |
| December | 0.625653E+09 | 94034867.71 | 0.309628E+09 | 54746880.90 | 0.254882E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.940632E+10 | 0.468843E+09 | 0.435908E+10 | 0.827653E+09 | 0.353142E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.624670E+09 | 8090370.36 | 0.303638E+09 | 44232434.88 | 0.254882E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.104988E+10 | 94034867.71 | 0.459122E+09 | 0.117821E+09 | 0.343543E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.309958E+09 | 48731569.71 | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.00 | 0.00 |
| February | 0.313512E+09 | 30645754.00 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| March | 0.376354E+09 | 18948366.43 | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.00 | 0.00 |
| April | 0.421100E+09 | 4433815.86 | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.00 | 0.00 |
| May | 0.547535E+09 | 8607900.87 | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.00 | 0.00 |
| June | 0.620097E+09 | 8884200.03 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
| July | 0.505664E+09 | 20578249.44 | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.00 | 0.00 |
| August | 0.423291E+09 | 14672571.86 | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.00 | 0.00 |
| September | 0.361330E+09 | 13594062.63 | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.00 | 0.00 |
| October | 0.333675E+09 | 19776996.85 | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.00 | 0.00 |
| November | 0.307369E+09 | 28241014.90 | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.00 | 0.00 |
| December | 0.297270E+09 | 57516475.53 | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.481716E+10 | 0.274631E+09 | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.297270E+09 | 4433815.86 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.620097E+09 | 57516475.53 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.309942E+09 | 48717985.25 | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.00 | 0.00 |
| February | 0.313496E+09 | 30635017.44 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| March | 0.376349E+09 | 18935277.01 | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.00 | 0.00 |
| April | 0.421093E+09 | 4430255.54 | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.00 | 0.00 |
| May | 0.547522E+09 | 8604020.65 | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.00 | 0.00 |
| June | 0.620085E+09 | 8883629.95 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
| July | 0.505649E+09 | 20572447.18 | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.00 | 0.00 |
| August | 0.423273E+09 | 14668818.22 | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.00 | 0.00 |
| September | 0.361312E+09 | 13591915.96 | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.00 | 0.00 |
| October | 0.333666E+09 | 19770588.93 | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.00 | 0.00 |
| November | 0.307358E+09 | 28236506.65 | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.00 | 0.00 |
| December | 0.297256E+09 | 57503942.95 | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.481700E+10 | 0.274550E+09 | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.297256E+09 | 4430255.54 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.620085E+09 | 57503942.95 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.753099E+09 | 48584808.05 | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.00 | 0.00 |
| February | 0.629637E+09 | 30369967.09 | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.00 | 0.00 |
| March | 0.522415E+09 | 17824193.68 | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.00 | 0.00 |
| April | 0.412505E+09 | 4301239.21 | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.00 | 0.00 |
| May | 0.430852E+09 | 8037160.95 | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.00 | 0.00 |
| June | 0.411222E+09 | 8224658.65 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| July | 0.378896E+09 | 19427983.13 | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.00 | 0.00 |
| August | 0.367071E+09 | 13549086.87 | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.00 | 0.00 |
| September | 0.401338E+09 | 13705475.74 | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.00 | 0.00 |
| October | 0.496036E+09 | 21050666.67 | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.00 | 0.00 |
| November | 0.613817E+09 | 30093079.07 | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.00 | 0.00 |
| December | 0.743845E+09 | 58510985.65 | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.616073E+10 | 0.273679E+09 | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.367071E+09 | 4301239.21 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.753099E+09 | 58510985.65 | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.750399E+09 | 50822318.82 | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.00 | 0.00 |
| February | 0.627089E+09 | 32251239.74 | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.00 | 0.00 |
| March | 0.519199E+09 | 19434723.67 | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.00 | 0.00 |
| April | 0.408124E+09 | 4860656.29 | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.00 | 0.00 |
| May | 0.426607E+09 | 8953335.36 | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.00 | 0.00 |
| June | 0.407247E+09 | 9129410.66 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| July | 0.375733E+09 | 21256185.68 | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.00 | 0.00 |
| August | 0.363640E+09 | 15017819.60 | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.00 | 0.00 |
| September | 0.398078E+09 | 15216265.90 | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.00 | 0.00 |
| October | 0.493094E+09 | 23135605.60 | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.00 | 0.00 |
| November | 0.611132E+09 | 32078766.25 | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.00 | 0.00 |
| December | 0.741426E+09 | 60668950.01 | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.612177E+10 | 0.292825E+09 | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.363640E+09 | 4860656.29 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.750399E+09 | 60668950.01 | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.111567E+10 | 77255471.49 | 0.560585E+09 | 0.220080E+09 | 0.340504E+09 | 0.00 | 0.00 |
| February | 0.998580E+09 | 47393462.61 | 0.476232E+09 | 0.162140E+09 | 0.314092E+09 | 0.00 | 0.00 |
| March | 0.990916E+09 | 28231202.89 | 0.447440E+09 | 0.120074E+09 | 0.327366E+09 | 0.00 | 0.00 |
| April | 0.883994E+09 | 6395771.50 | 0.380824E+09 | 85867127.96 | 0.294957E+09 | 0.00 | 0.00 |
| May | 0.867301E+09 | 11728705.40 | 0.357824E+09 | 57412683.88 | 0.300411E+09 | 0.00 | 0.00 |
| June | 0.859536E+09 | 12179481.72 | 0.361303E+09 | 69965590.50 | 0.291338E+09 | 0.00 | 0.00 |
| July | 0.751638E+09 | 29011422.76 | 0.347506E+09 | 42298116.40 | 0.305208E+09 | 0.00 | 0.00 |
| August | 0.762872E+09 | 19547948.46 | 0.358624E+09 | 57893469.97 | 0.300731E+09 | 0.00 | 0.00 |
| September | 0.769839E+09 | 19973228.18 | 0.351075E+09 | 53606752.33 | 0.297468E+09 | 0.00 | 0.00 |
| October | 0.835572E+09 | 31369469.13 | 0.407128E+09 | 80454669.05 | 0.326673E+09 | 0.00 | 0.00 |
| November | 0.934095E+09 | 45821225.17 | 0.463137E+09 | 0.137965E+09 | 0.325172E+09 | 0.00 | 0.00 |
| December | 0.107873E+10 | 92708219.25 | 0.549003E+09 | 0.216149E+09 | 0.332854E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.108487E+11 | 0.421616E+09 | 0.506068E+10 | 0.130391E+10 | 0.375678E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.751638E+09 | 6395771.50 | 0.347506E+09 | 42298116.40 | 0.291338E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.111567E+10 | 92708219.25 | 0.560585E+09 | 0.220080E+09 | 0.340504E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.678509E+09 | 78081626.63 | 0.327895E+09 | 65202191.82 | 0.262693E+09 | 0.00 | 0.00 |
| February | 0.686575E+09 | 48150728.47 | 0.320722E+09 | 64659888.95 | 0.256062E+09 | 0.00 | 0.00 |
| March | 0.846386E+09 | 29572898.19 | 0.383818E+09 | 89713399.09 | 0.294105E+09 | 0.00 | 0.00 |
| April | 0.891606E+09 | 6519914.79 | 0.387508E+09 | 87321178.15 | 0.300187E+09 | 0.00 | 0.00 |
| May | 0.981665E+09 | 12354797.76 | 0.413273E+09 | 81361494.92 | 0.331912E+09 | 0.00 | 0.00 |
| June | 0.106464E+10 | 12850750.09 | 0.461046E+09 | 0.121464E+09 | 0.339582E+09 | 0.00 | 0.00 |
| July | 0.876346E+09 | 30345190.69 | 0.408247E+09 | 65614104.39 | 0.342633E+09 | 0.00 | 0.00 |
| August | 0.817785E+09 | 20813952.23 | 0.385571E+09 | 67158033.69 | 0.318413E+09 | 0.00 | 0.00 |
| September | 0.730287E+09 | 19856720.40 | 0.332513E+09 | 49008147.86 | 0.283505E+09 | 0.00 | 0.00 |
| October | 0.675323E+09 | 29910303.85 | 0.326519E+09 | 44135038.74 | 0.282384E+09 | 0.00 | 0.00 |
| November | 0.631431E+09 | 43816172.06 | 0.303564E+09 | 43864372.98 | 0.259700E+09 | 0.00 | 0.00 |
| December | 0.638225E+09 | 92214156.47 | 0.310219E+09 | 56014806.47 | 0.254205E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.951878E+10 | 0.424487E+09 | 0.436089E+10 | 0.835516E+09 | 0.352538E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.631431E+09 | 6519914.79 | 0.303564E+09 | 43864372.98 | 0.254205E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.106464E+10 | 92214156.47 | 0.461046E+09 | 0.121464E+09 | 0.342633E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.110938E+10 | 75386569.38 | 0.558119E+09 | 0.216554E+09 | 0.341565E+09 | 0.00 | 0.00 |
| February | 0.100290E+10 | 45725035.94 | 0.479176E+09 | 0.165226E+09 | 0.313950E+09 | 0.00 | 0.00 |
| March | 0.986923E+09 | 25805268.70 | 0.445407E+09 | 0.118262E+09 | 0.327145E+09 | 0.00 | 0.00 |
| April | 0.888080E+09 | 6187912.96 | 0.380404E+09 | 85693325.38 | 0.294710E+09 | 0.00 | 0.00 |
| May | 0.872513E+09 | 11721663.93 | 0.359105E+09 | 59006733.03 | 0.300098E+09 | 0.00 | 0.00 |
| June | 0.857741E+09 | 12017008.50 | 0.359380E+09 | 66322556.51 | 0.293057E+09 | 0.00 | 0.00 |
| July | 0.749201E+09 | 28832979.59 | 0.346019E+09 | 39900904.34 | 0.306118E+09 | 0.00 | 0.00 |
| August | 0.765603E+09 | 19722813.17 | 0.359048E+09 | 57453784.56 | 0.301594E+09 | 0.00 | 0.00 |
| September | 0.774555E+09 | 19743111.04 | 0.352459E+09 | 53318184.99 | 0.299141E+09 | 0.00 | 0.00 |
| October | 0.838734E+09 | 31030711.99 | 0.408124E+09 | 80552065.18 | 0.327572E+09 | 0.00 | 0.00 |
| November | 0.934688E+09 | 45431476.14 | 0.463210E+09 | 0.138873E+09 | 0.324338E+09 | 0.00 | 0.00 |
| December | 0.107539E+10 | 91377183.58 | 0.548412E+09 | 0.214881E+09 | 0.333531E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.108557E+11 | 0.412982E+09 | 0.505886E+10 | 0.129604E+10 | 0.376282E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.749201E+09 | 6187912.96 | 0.346019E+09 | 39900904.34 | 0.293057E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.110938E+10 | 91377183.58 | 0.558119E+09 | 0.216554E+09 | 0.341565E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.668881E+09 | 72817683.75 | 0.325429E+09 | 61675549.49 | 0.263754E+09 | 0.00 | 0.00 |
| February | 0.689168E+09 | 44722939.49 | 0.323666E+09 | 67745811.95 | 0.255920E+09 | 0.00 | 0.00 |
| March | 0.842178E+09 | 26905459.32 | 0.381785E+09 | 87901725.16 | 0.293883E+09 | 0.00 | 0.00 |
| April | 0.895623E+09 | 6276845.59 | 0.387087E+09 | 87147375.57 | 0.299940E+09 | 0.00 | 0.00 |
| May | 0.986947E+09 | 12413987.60 | 0.414555E+09 | 82955544.07 | 0.331599E+09 | 0.00 | 0.00 |
| June | 0.106310E+10 | 12884523.61 | 0.459122E+09 | 0.117821E+09 | 0.341302E+09 | 0.00 | 0.00 |
| July | 0.874097E+09 | 30360709.14 | 0.406760E+09 | 63216892.33 | 0.343543E+09 | 0.00 | 0.00 |
| August | 0.820739E+09 | 21163325.14 | 0.385994E+09 | 66718348.27 | 0.319276E+09 | 0.00 | 0.00 |
| September | 0.735039E+09 | 19675326.31 | 0.333897E+09 | 48719580.52 | 0.285177E+09 | 0.00 | 0.00 |
| October | 0.678351E+09 | 29440447.67 | 0.327514E+09 | 44232434.88 | 0.283282E+09 | 0.00 | 0.00 |
| November | 0.631242E+09 | 42648838.52 | 0.303638E+09 | 44772595.62 | 0.258866E+09 | 0.00 | 0.00 |
| December | 0.631647E+09 | 87620317.62 | 0.309628E+09 | 54746880.90 | 0.254882E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.951701E+10 | 0.406930E+09 | 0.435908E+10 | 0.827653E+09 | 0.353142E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.631242E+09 | 6276845.59 | 0.303638E+09 | 44232434.88 | 0.254882E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.106310E+10 | 87620317.62 | 0.459122E+09 | 0.117821E+09 | 0.343543E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.313278E+09 | 45616463.23 | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.00 | 0.00 |
| February | 0.317124E+09 | 27734970.79 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| March | 0.381362E+09 | 16379931.66 | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.00 | 0.00 |
| April | 0.427953E+09 | 3560540.18 | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.00 | 0.00 |
| May | 0.554196E+09 | 6941833.97 | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.00 | 0.00 |
| June | 0.626640E+09 | 7237892.92 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
| July | 0.510010E+09 | 17306860.57 | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.00 | 0.00 |
| August | 0.428986E+09 | 12062024.02 | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.00 | 0.00 |
| September | 0.366708E+09 | 11100717.35 | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.00 | 0.00 |
| October | 0.337627E+09 | 16785949.39 | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.00 | 0.00 |
| November | 0.310934E+09 | 25212506.74 | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.00 | 0.00 |
| December | 0.300515E+09 | 54252495.90 | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.487533E+10 | 0.244192E+09 | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.300515E+09 | 3560540.18 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.626640E+09 | 54252495.90 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.313261E+09 | 45601195.74 | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.00 | 0.00 |
| February | 0.317108E+09 | 27722514.44 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| March | 0.381354E+09 | 16366075.35 | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.00 | 0.00 |
| April | 0.427947E+09 | 3557434.24 | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.00 | 0.00 |
| May | 0.554185E+09 | 6937971.18 | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.00 | 0.00 |
| June | 0.626629E+09 | 7235834.12 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
| July | 0.509996E+09 | 17299806.30 | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.00 | 0.00 |
| August | 0.428968E+09 | 12056990.59 | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.00 | 0.00 |
| September | 0.366693E+09 | 11097365.70 | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.00 | 0.00 |
| October | 0.337617E+09 | 16779107.62 | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.00 | 0.00 |
| November | 0.310922E+09 | 25205896.73 | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.00 | 0.00 |
| December | 0.300499E+09 | 54239033.11 | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.487518E+10 | 0.244099E+09 | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.300499E+09 | 3557434.24 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.626629E+09 | 54239033.11 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.755295E+09 | 44709973.46 | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.00 | 0.00 |
| February | 0.632646E+09 | 26859000.42 | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.00 | 0.00 |
| March | 0.527542E+09 | 14792033.17 | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.00 | 0.00 |
| April | 0.420412E+09 | 3495674.70 | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.00 | 0.00 |
| May | 0.438730E+09 | 6475848.96 | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.00 | 0.00 |
| June | 0.419440E+09 | 6734099.54 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| July | 0.384073E+09 | 16266020.05 | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.00 | 0.00 |
| August | 0.373507E+09 | 10885182.43 | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.00 | 0.00 |
| September | 0.406705E+09 | 11160227.90 | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.00 | 0.00 |
| October | 0.499389E+09 | 17866518.13 | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.00 | 0.00 |
| November | 0.616559E+09 | 26718497.65 | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.00 | 0.00 |
| December | 0.745878E+09 | 54637654.90 | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.622018E+10 | 0.240601E+09 | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.373507E+09 | 3495674.70 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.755295E+09 | 54637654.90 | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.755281E+09 | 44695583.51 | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.00 | 0.00 |
| February | 0.632632E+09 | 26848094.65 | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.00 | 0.00 |
| March | 0.527537E+09 | 14778725.33 | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.00 | 0.00 |
| April | 0.420407E+09 | 3492938.11 | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.00 | 0.00 |
| May | 0.438719E+09 | 6472304.58 | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.00 | 0.00 |
| June | 0.419427E+09 | 6732234.94 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| July | 0.384059E+09 | 16259243.36 | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.00 | 0.00 |
| August | 0.373489E+09 | 10879841.11 | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.00 | 0.00 |
| September | 0.406689E+09 | 11156828.06 | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.00 | 0.00 |
| October | 0.499380E+09 | 17859541.24 | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.00 | 0.00 |
| November | 0.616549E+09 | 26711889.55 | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.00 | 0.00 |
| December | 0.745864E+09 | 54624599.36 | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.622003E+10 | 0.240512E+09 | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.373489E+09 | 3492938.11 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.755281E+09 | 54624599.36 | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.109297E+10 | 75040551.43 | 0.560585E+09 | 0.220080E+09 | 0.340504E+09 | 0.00 | 0.00 |
| February | 0.976445E+09 | 45103943.95 | 0.476232E+09 | 0.162140E+09 | 0.314092E+09 | 0.00 | 0.00 |
| March | 0.965361E+09 | 26981350.76 | 0.447440E+09 | 0.120074E+09 | 0.327366E+09 | 0.00 | 0.00 |
| April | 0.858130E+09 | 6071625.38 | 0.380824E+09 | 85867127.96 | 0.294957E+09 | 0.00 | 0.00 |
| May | 0.841783E+09 | 11812765.25 | 0.357824E+09 | 57412683.88 | 0.300411E+09 | 0.00 | 0.00 |
| June | 0.833899E+09 | 12365941.14 | 0.361303E+09 | 69965590.50 | 0.291338E+09 | 0.00 | 0.00 |
| July | 0.729364E+09 | 28998685.06 | 0.347506E+09 | 42298116.40 | 0.305208E+09 | 0.00 | 0.00 |
| August | 0.740779E+09 | 19170886.03 | 0.358624E+09 | 57893469.97 | 0.300731E+09 | 0.00 | 0.00 |
| September | 0.747285E+09 | 20050593.38 | 0.351075E+09 | 53606752.33 | 0.297468E+09 | 0.00 | 0.00 |
| October | 0.814504E+09 | 31268613.41 | 0.407128E+09 | 80454669.05 | 0.326673E+09 | 0.00 | 0.00 |
| November | 0.912857E+09 | 44476280.38 | 0.463137E+09 | 0.137965E+09 | 0.325172E+09 | 0.00 | 0.00 |
| December | 0.105741E+10 | 90224825.97 | 0.549003E+09 | 0.216149E+09 | 0.332854E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105708E+11 | 0.411566E+09 | 0.506068E+10 | 0.130391E+10 | 0.375678E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.729364E+09 | 6071625.38 | 0.347506E+09 | 42298116.40 | 0.291338E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.109297E+10 | 90224825.97 | 0.560585E+09 | 0.220080E+09 | 0.340504E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.659943E+09 | 76327790.99 | 0.327895E+09 | 65202191.82 | 0.262693E+09 | 0.00 | 0.00 |
| February | 0.667600E+09 | 46486940.27 | 0.320722E+09 | 64659888.95 | 0.256062E+09 | 0.00 | 0.00 |
| March | 0.822634E+09 | 28890331.45 | 0.383818E+09 | 89713399.09 | 0.294105E+09 | 0.00 | 0.00 |
| April | 0.865506E+09 | 6203487.01 | 0.387508E+09 | 87321178.15 | 0.300187E+09 | 0.00 | 0.00 |
| May | 0.954881E+09 | 12336013.13 | 0.413273E+09 | 81361494.92 | 0.331912E+09 | 0.00 | 0.00 |
| June | 0.103715E+10 | 12930376.64 | 0.461046E+09 | 0.121464E+09 | 0.339582E+09 | 0.00 | 0.00 |
| July | 0.852590E+09 | 30221165.31 | 0.408247E+09 | 65614104.39 | 0.342633E+09 | 0.00 | 0.00 |
| August | 0.795295E+09 | 20478660.23 | 0.385571E+09 | 67158033.69 | 0.318413E+09 | 0.00 | 0.00 |
| September | 0.708327E+09 | 19989407.48 | 0.332513E+09 | 49008147.86 | 0.283505E+09 | 0.00 | 0.00 |
| October | 0.656080E+09 | 30040037.77 | 0.326519E+09 | 44135038.74 | 0.282384E+09 | 0.00 | 0.00 |
| November | 0.613141E+09 | 42871003.20 | 0.303564E+09 | 43864372.98 | 0.259700E+09 | 0.00 | 0.00 |
| December | 0.620899E+09 | 89885728.84 | 0.310219E+09 | 56014806.47 | 0.254205E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.925405E+10 | 0.416661E+09 | 0.436089E+10 | 0.835516E+09 | 0.352538E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.613141E+09 | 6203487.01 | 0.303564E+09 | 43864372.98 | 0.254205E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.103715E+10 | 89885728.84 | 0.461046E+09 | 0.121464E+09 | 0.342633E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.108610E+10 | 72704386.59 | 0.558119E+09 | 0.216554E+09 | 0.341565E+09 | 0.00 | 0.00 |
| February | 0.980346E+09 | 43149542.19 | 0.479176E+09 | 0.165226E+09 | 0.313950E+09 | 0.00 | 0.00 |
| March | 0.960847E+09 | 24264862.96 | 0.445407E+09 | 0.118262E+09 | 0.327145E+09 | 0.00 | 0.00 |
| April | 0.862032E+09 | 5864358.49 | 0.380404E+09 | 85693325.38 | 0.294710E+09 | 0.00 | 0.00 |
| May | 0.846920E+09 | 11782369.82 | 0.359105E+09 | 59006733.03 | 0.300098E+09 | 0.00 | 0.00 |
| June | 0.832117E+09 | 12156146.44 | 0.359380E+09 | 66322556.51 | 0.293057E+09 | 0.00 | 0.00 |
| July | 0.727086E+09 | 28740936.37 | 0.346019E+09 | 39900904.34 | 0.306118E+09 | 0.00 | 0.00 |
| August | 0.743632E+09 | 19282141.81 | 0.359048E+09 | 57453784.56 | 0.301594E+09 | 0.00 | 0.00 |
| September | 0.752115E+09 | 19760524.51 | 0.352459E+09 | 53318184.99 | 0.299141E+09 | 0.00 | 0.00 |
| October | 0.817393E+09 | 30743850.69 | 0.408124E+09 | 80552065.18 | 0.327572E+09 | 0.00 | 0.00 |
| November | 0.913223E+09 | 43946254.18 | 0.463210E+09 | 0.138873E+09 | 0.324338E+09 | 0.00 | 0.00 |
| December | 0.105354E+10 | 88520002.75 | 0.548412E+09 | 0.214881E+09 | 0.333531E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105754E+11 | 0.400915E+09 | 0.505886E+10 | 0.129604E+10 | 0.376282E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.727086E+09 | 5864358.49 | 0.346019E+09 | 39900904.34 | 0.293057E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.108610E+10 | 88520002.75 | 0.558119E+09 | 0.216554E+09 | 0.341565E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.650086E+09 | 70988442.01 | 0.325429E+09 | 61675549.49 | 0.263754E+09 | 0.00 | 0.00 |
| February | 0.669911E+09 | 42953461.76 | 0.323666E+09 | 67745811.95 | 0.255920E+09 | 0.00 | 0.00 |
| March | 0.817794E+09 | 25834094.68 | 0.381785E+09 | 87901725.16 | 0.293883E+09 | 0.00 | 0.00 |
| April | 0.869286E+09 | 5944897.73 | 0.387087E+09 | 87147375.57 | 0.299940E+09 | 0.00 | 0.00 |
| May | 0.960070E+09 | 12374198.97 | 0.414555E+09 | 82955544.07 | 0.331599E+09 | 0.00 | 0.00 |
| June | 0.103559E+10 | 12867958.29 | 0.459122E+09 | 0.117821E+09 | 0.341302E+09 | 0.00 | 0.00 |
| July | 0.850450E+09 | 30111916.25 | 0.406760E+09 | 63216892.33 | 0.343543E+09 | 0.00 | 0.00 |
| August | 0.798386E+09 | 20740649.43 | 0.385994E+09 | 66718348.27 | 0.319276E+09 | 0.00 | 0.00 |
| September | 0.713160E+09 | 19735827.72 | 0.333897E+09 | 48719580.52 | 0.285177E+09 | 0.00 | 0.00 |
| October | 0.658848E+09 | 29411217.57 | 0.327514E+09 | 44232434.88 | 0.283282E+09 | 0.00 | 0.00 |
| November | 0.612823E+09 | 41712716.84 | 0.303638E+09 | 44772595.62 | 0.258866E+09 | 0.00 | 0.00 |
| December | 0.614179E+09 | 85376712.69 | 0.309628E+09 | 54746880.90 | 0.254882E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.925059E+10 | 0.398052E+09 | 0.435908E+10 | 0.827653E+09 | 0.353142E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.612823E+09 | 5944897.73 | 0.303638E+09 | 44232434.88 | 0.254882E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.103559E+10 | 85376712.69 | 0.459122E+09 | 0.117821E+09 | 0.343543E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.303746E+09 | 45188460.09 | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.00 | 0.00 |
| February | 0.307430E+09 | 27312076.18 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| March | 0.369056E+09 | 16423627.11 | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.00 | 0.00 |
| April | 0.414036E+09 | 3555180.94 | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.00 | 0.00 |
| May | 0.539806E+09 | 7241038.45 | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.00 | 0.00 |
| June | 0.611874E+09 | 7548982.91 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
| July | 0.497372E+09 | 17718506.04 | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.00 | 0.00 |
| August | 0.417229E+09 | 12265796.39 | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.00 | 0.00 |
| September | 0.355180E+09 | 11588911.84 | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.00 | 0.00 |
| October | 0.327537E+09 | 17370652.27 | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.00 | 0.00 |
| November | 0.301467E+09 | 25241705.85 | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.00 | 0.00 |
| December | 0.291649E+09 | 53575853.00 | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.473638E+10 | 0.245031E+09 | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.291649E+09 | 3555180.94 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.611874E+09 | 53575853.00 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.303704E+09 | 45148795.09 | 0.143261E+09 | 0.00 | 0.143261E+09 | 0.00 | 0.00 |
| February | 0.307393E+09 | 27283660.06 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| March | 0.369038E+09 | 16392340.97 | 0.156968E+09 | 27717.86 | 0.156941E+09 | 0.00 | 0.00 |
| April | 0.414029E+09 | 3549337.03 | 0.167309E+09 | 3153176.52 | 0.164156E+09 | 0.00 | 0.00 |
| May | 0.539788E+09 | 7233182.22 | 0.219437E+09 | 23948811.03 | 0.195488E+09 | 0.00 | 0.00 |
| June | 0.611852E+09 | 7540547.54 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
| July | 0.497342E+09 | 17700139.41 | 0.229065E+09 | 23315987.99 | 0.205749E+09 | 0.00 | 0.00 |
| August | 0.417195E+09 | 12249886.54 | 0.190658E+09 | 9365144.59 | 0.181293E+09 | 0.00 | 0.00 |
| September | 0.355152E+09 | 11576368.91 | 0.156175E+09 | 215465.36 | 0.155959E+09 | 0.00 | 0.00 |
| October | 0.327512E+09 | 17352143.17 | 0.155227E+09 | 0.00 | 0.155227E+09 | 0.00 | 0.00 |
| November | 0.301441E+09 | 25221894.09 | 0.142141E+09 | 0.00 | 0.142141E+09 | 0.00 | 0.00 |
| December | 0.291608E+09 | 53540804.49 | 0.139176E+09 | 0.00 | 0.139176E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.473606E+10 | 0.244789E+09 | 0.209531E+10 | 0.111524E+09 | 0.198379E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.291608E+09 | 3549337.03 | 0.138031E+09 | 0.00 | 0.138031E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.611852E+09 | 53540804.49 | 0.257868E+09 | 51498041.14 | 0.206370E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.742920E+09 | 43865022.23 | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.00 | 0.00 |
| February | 0.620822E+09 | 25949299.32 | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.00 | 0.00 |
| March | 0.514098E+09 | 14458688.51 | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.00 | 0.00 |
| April | 0.406736E+09 | 3477862.05 | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.00 | 0.00 |
| May | 0.425218E+09 | 6823927.78 | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.00 | 0.00 |
| June | 0.405887E+09 | 7120956.50 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| July | 0.372469E+09 | 16741774.25 | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.00 | 0.00 |
| August | 0.361962E+09 | 11045102.62 | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.00 | 0.00 |
| September | 0.394762E+09 | 11618179.68 | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.00 | 0.00 |
| October | 0.488023E+09 | 18320257.85 | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.00 | 0.00 |
| November | 0.605124E+09 | 26471770.68 | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.00 | 0.00 |
| December | 0.734244E+09 | 53727418.40 | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.607227E+10 | 0.239620E+09 | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.361962E+09 | 3477862.05 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.742920E+09 | 53727418.40 | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.742886E+09 | 43827488.82 | 0.375951E+09 | 0.154878E+09 | 0.221073E+09 | 0.00 | 0.00 |
| February | 0.620793E+09 | 25923235.25 | 0.293541E+09 | 97480310.57 | 0.196061E+09 | 0.00 | 0.00 |
| March | 0.514086E+09 | 14429400.77 | 0.220591E+09 | 30388404.33 | 0.190202E+09 | 0.00 | 0.00 |
| April | 0.406732E+09 | 3472808.89 | 0.160625E+09 | 1699126.33 | 0.158926E+09 | 0.00 | 0.00 |
| May | 0.425201E+09 | 6816663.13 | 0.163987E+09 | 0.00 | 0.163987E+09 | 0.00 | 0.00 |
| June | 0.405864E+09 | 7112770.87 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| July | 0.372440E+09 | 16723197.40 | 0.168323E+09 | 0.00 | 0.168323E+09 | 0.00 | 0.00 |
| August | 0.361927E+09 | 11029610.72 | 0.163711E+09 | 100580.87 | 0.163611E+09 | 0.00 | 0.00 |
| September | 0.394734E+09 | 11605351.81 | 0.174737E+09 | 4814069.83 | 0.169923E+09 | 0.00 | 0.00 |
| October | 0.488000E+09 | 18301497.79 | 0.235836E+09 | 36319630.31 | 0.199517E+09 | 0.00 | 0.00 |
| November | 0.605103E+09 | 26452764.40 | 0.301713E+09 | 94100218.45 | 0.207613E+09 | 0.00 | 0.00 |
| December | 0.734210E+09 | 53693671.16 | 0.377960E+09 | 0.160134E+09 | 0.217826E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.607198E+10 | 0.239388E+09 | 0.279510E+10 | 0.579914E+09 | 0.221519E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.361927E+09 | 3472808.89 | 0.158126E+09 | 0.00 | 0.158126E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.742886E+09 | 53693671.16 | 0.377960E+09 | 0.160134E+09 | 0.221073E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 79313066.26 | 11236909.48 | 43712024.36 | 14799299.15 | 28912725.21 | 0.00 | 0.00 |
| February | 83307081.41 | 7709394.12 | 44543766.57 | 16255883.33 | 28287883.24 | 0.00 | 0.00 |
| March | 0.102799E+09 | 5961940.71 | 53945710.55 | 21085725.73 | 32859984.82 | 0.00 | 0.00 |
| April | 0.102822E+09 | 2317766.85 | 52736661.19 | 20154749.95 | 32581911.24 | 0.00 | 0.00 |
| May | 94442413.82 | 3489917.48 | 46819388.08 | 14158905.77 | 32660482.31 | 0.00 | 0.00 |
| June | 96103235.07 | 3653292.79 | 48291756.52 | 15914367.39 | 32377389.13 | 0.00 | 0.00 |
| July | 80301342.63 | 6595196.19 | 42638762.10 | 9574384.41 | 33064377.69 | 0.00 | 0.00 |
| August | 86919904.71 | 5706611.22 | 46871789.94 | 13762134.68 | 33109655.27 | 0.00 | 0.00 |
| September | 81153132.51 | 5354258.63 | 42645162.77 | 11638759.86 | 31006402.91 | 0.00 | 0.00 |
| October | 74801716.38 | 7170678.90 | 41341127.91 | 10613752.79 | 30727375.12 | 0.00 | 0.00 |
| November | 70406162.19 | 8164325.82 | 38751984.03 | 10743366.56 | 28008617.47 | 0.00 | 0.00 |
| December | 73846974.14 | 12946801.53 | 40900727.06 | 13136736.91 | 27763990.15 | 0.00 | 0.00 |
| Annual Sum or Average | 0.102622E+10 | 80307093.74 | 0.543199E+09 | 0.171838E+09 | 0.371361E+09 | 0.00 | 0.00 |
| Minimum of Months | 70406162.19 | 2317766.85 | 38751984.03 | 9574384.41 | 27763990.15 | 0.00 | 0.00 |
| Maximum of Months | 0.102822E+09 | 12946801.53 | 53945710.55 | 21085725.73 | 33109655.27 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.231285E+09 | 40830469.08 | 0.130185E+09 | 44075995.86 | 86109291.01 | 0.00 | 0.00 |
| February | 0.242385E+09 | 30485792.74 | 0.132662E+09 | 48414066.05 | 84248356.10 | 0.00 | 0.00 |
| March | 0.299294E+09 | 26030281.70 | 0.160664E+09 | 62798538.70 | 97865212.43 | 0.00 | 0.00 |
| April | 0.297752E+09 | 13457835.69 | 0.157063E+09 | 60025861.14 | 97037040.12 | 0.00 | 0.00 |
| May | 0.271067E+09 | 15842060.67 | 0.139440E+09 | 42168745.02 | 97271044.32 | 0.00 | 0.00 |
| June | 0.277526E+09 | 16822278.99 | 0.143825E+09 | 47396946.60 | 96427922.36 | 0.00 | 0.00 |
| July | 0.232910E+09 | 25721491.84 | 0.126989E+09 | 28514899.48 | 98473945.26 | 0.00 | 0.00 |
| August | 0.251942E+09 | 23560459.30 | 0.139596E+09 | 40987061.95 | 98608793.17 | 0.00 | 0.00 |
| September | 0.235439E+09 | 21922790.16 | 0.127008E+09 | 34663123.33 | 92344784.22 | 0.00 | 0.00 |
| October | 0.217497E+09 | 27784414.56 | 0.123124E+09 | 31610397.19 | 91513770.02 | 0.00 | 0.00 |
| November | 0.205039E+09 | 30789656.06 | 0.115413E+09 | 31996419.25 | 83416633.15 | 0.00 | 0.00 |
| December | 0.215341E+09 | 45586171.84 | 0.121813E+09 | 39124471.78 | 82688072.10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.297748E+10 | 0.318834E+09 | 0.161778E+10 | 0.511777E+09 | 0.110600E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.205039E+09 | 13457835.69 | 0.115413E+09 | 28514899.48 | 82688072.10 | 0.00 | 0.00 |
| Maximum of Months | 0.299294E+09 | 45586171.84 | 0.160664E+09 | 62798538.70 | 98608793.17 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 80634188.63 | 11137879.70 | 43712024.36 | 14799299.15 | 28912725.21 | 0.00 | 0.00 |
| February | 84804431.35 | 7678985.58 | 44543766.57 | 16255883.33 | 28287883.24 | 0.00 | 0.00 |
| March | 0.104926E+09 | 5754950.30 | 53945710.55 | 21085725.73 | 32859984.82 | 0.00 | 0.00 |
| April | 0.105555E+09 | 2229001.52 | 52736661.19 | 20154749.95 | 32581911.24 | 0.00 | 0.00 |
| May | 97190540.77 | 3241578.70 | 46819388.08 | 14158905.77 | 32660482.31 | 0.00 | 0.00 |
| June | 98738190.87 | 3344461.44 | 48291756.52 | 15914367.39 | 32377389.13 | 0.00 | 0.00 |
| July | 82232553.10 | 6279288.36 | 42638762.10 | 9574384.41 | 33064377.69 | 0.00 | 0.00 |
| August | 88727569.49 | 5365331.14 | 46871789.94 | 13762134.68 | 33109655.27 | 0.00 | 0.00 |
| September | 83110282.18 | 5014193.56 | 42645162.77 | 11638759.86 | 31006402.91 | 0.00 | 0.00 |
| October | 76432341.99 | 6845013.48 | 41341127.91 | 10613752.79 | 30727375.12 | 0.00 | 0.00 |
| November | 71862376.72 | 7959103.58 | 38751984.03 | 10743366.56 | 28008617.47 | 0.00 | 0.00 |
| December | 74996577.65 | 12881330.49 | 40900727.06 | 13136736.91 | 27763990.15 | 0.00 | 0.00 |
| Annual Sum or Average | 0.104921E+10 | 77731117.85 | 0.543199E+09 | 0.171838E+09 | 0.371361E+09 | 0.00 | 0.00 |
| Minimum of Months | 71862376.72 | 2229001.52 | 38751984.03 | 9574384.41 | 27763990.15 | 0.00 | 0.00 |
| Maximum of Months | 0.105555E+09 | 12881330.49 | 53945710.55 | 21085725.73 | 33109655.27 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 26.42 | 22.38 | 20.70 | 2.25 | 18.66 | 103.85 | 146.57 | 0.01 |
| February | 27.50 | 22.91 | 21.01 | 2.37 | 18.54 | 110.59 | 164.59 | 0.00 |
| March | 28.33 | 23.63 | 21.77 | 3.67 | 19.85 | 110.33 | 194.39 | 0.01 |
| April | 29.15 | 25.37 | 24.04 | 2.98 | 21.51 | 118.69 | 185.56 | 0.03 |
| May | 29.01 | 26.53 | 25.72 | 3.19 | 23.00 | 127.71 | 124.87 | 0.08 |
| June | 28.86 | 26.50 | 25.74 | 3.10 | 22.78 | 123.38 | 156.09 | 0.05 |
| July | 27.25 | 24.29 | 23.20 | 2.32 | 21.53 | 137.39 | 88.28 | 0.02 |
| August | 27.54 | 25.86 | 25.31 | 3.22 | 21.55 | 129.55 | 122.00 | 0.07 |
| September | 27.58 | 25.59 | 24.93 | 2.22 | 22.01 | 128.30 | 103.37 | 0.04 |
| October | 26.89 | 25.07 | 24.46 | 2.18 | 21.39 | 123.79 | 92.41 | 0.11 |
| November | 26.68 | 24.14 | 23.20 | 1.94 | 20.29 | 113.70 | 103.30 | 0.02 |
| December | 25.97 | 22.85 | 21.57 | 2.00 | 18.63 | 101.83 | 131.96 | 0.00 |
| Annual Sum or Average | 27.59 | 24.60 | 23.48 | 2.62 | 20.82 | 119.14 | 134.17 | 0.04 |
| Minimum of Months | 25.97 | 22.38 | 20.70 | 1.94 | 18.54 | 101.83 | 88.28 | 0.00 |
| Maximum of Months | 29.15 | 26.53 | 25.74 | 3.67 | 23.00 | 137.39 | 194.39 | 0.11 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 34.10 | 04-JAN-12:00 | 23.67 | 19.40 | 5.00 | 24.66 | 266.50 | 576.50 |
| February | 35.00 | 21-FEB-13:00 | 22.02 | 16.00 | 2.10 | 24.16 | 230.00 | 672.50 |
| March | 36.40 | 21-MAR-12:00 | 23.01 | 17.00 | 5.00 | 26.97 | 269.50 | 658.50 |
| April | 35.50 | 01-APR-13:00 | 26.96 | 24.00 | 2.50 | 27.14 | 295.50 | 519.50 |
| May | 37.60 | 06-MAY-12:00 | 26.43 | 22.60 | 4.00 | 29.39 | 317.00 | 525.50 |
| June | 36.00 | 12-JUN-14:00 | 27.60 | 25.00 | 4.00 | 28.43 | 235.00 | 472.00 |
| July | 33.20 | 15-JUL-15:00 | 25.63 | 23.00 | 2.00 | 27.95 | 219.00 | 181.00 |
| August | 34.00 | 10-AUG-13:00 | 27.86 | 26.00 | 5.00 | 26.65 | 344.50 | 278.50 |
| September | 34.00 | 06-SEP-13:00 | 26.51 | 24.00 | 4.00 | 25.00 | 258.00 | 581.50 |
| October | 33.00 | 04-OCT-13:00 | 26.23 | 24.00 | 4.00 | 25.16 | 303.00 | 428.50 |
| November | 34.30 | 18-NOV-12:00 | 25.34 | 22.20 | 3.00 | 25.49 | 289.50 | 511.50 |
| December | 33.00 | 07-DEC-13:00 | 23.23 | 19.00 | 3.00 | 22.98 | 215.00 | 596.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 33.00 | 22.02 | 16.00 | 2.00 | 22.98 | 215.00 | 181.00 | |
| Maximum of Months | 37.60 | 27.86 | 26.00 | 5.00 | 29.39 | 344.50 | 672.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 18.70 | 23-JAN-05:00 | 16.92 | 16.00 | 2.00 | 7.75 | 0.00 | 0.00 |
| February | 20.30 | 21-FEB-09:00 | 19.04 | 18.40 | 2.00 | 10.50 | 258.50 | 564.00 |
| March | 22.00 | 03-MAR-05:00 | 19.94 | 19.00 | 3.00 | 13.35 | 0.00 | 0.00 |
| April | 22.90 | 14-APR-15:00 | 22.90 | 22.90 | 3.00 | 14.65 | 199.50 | 264.50 |
| May | 22.00 | 10-MAY-19:00 | 22.00 | 22.00 | 2.00 | 18.28 | 0.00 | 0.00 |
| June | 23.00 | 20-JUN-23:00 | 23.00 | 23.00 | 2.00 | 19.35 | 0.00 | 0.00 |
| July | 23.00 | 13-JUL-04:00 | 22.27 | 22.00 | 0.00 | 13.91 | 0.00 | 0.00 |
| August | 22.00 | 20-AUG-10:00 | 22.00 | 22.00 | 5.00 | 18.28 | 430.50 | 41.50 |
| September | 22.90 | 19-SEP-03:00 | 22.78 | 22.78 | 0.00 | 21.27 | 0.00 | 0.00 |
| October | 22.50 | 23-OCT-04:00 | 22.50 | 22.50 | 2.80 | 18.82 | 0.00 | 0.00 |
| November | 20.00 | 25-NOV-04:00 | 18.63 | 18.00 | 2.00 | 10.69 | 0.00 | 0.00 |
| December | 18.00 | 21-DEC-04:00 | 17.36 | 17.00 | 3.00 | 9.13 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 18.00 | 16.92 | 16.00 | 0.00 | 7.75 | 0.00 | 0.00 | |
| Maximum of Months | 23.00 | 23.00 | 23.00 | 5.00 | 21.27 | 430.50 | 564.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 25.53 | 12-JAN-12:00 | 32.40 | 23.10 | 2.00 | 25.00 | 353.00 | 347.00 |
| February | 26.17 | 14-FEB-15:00 | 32.30 | 24.20 | 2.00 | 25.16 | 200.00 | 199.00 |
| March | 26.28 | 27-MAR-12:00 | 34.20 | 23.60 | 4.00 | 26.32 | 326.00 | 535.00 |
| April | 27.93 | 10-APR-16:49 | 31.52 | 26.85 | 4.08 | 27.70 | 110.67 | 57.00 |
| May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
| June | 30.11 | 15-JUN-09:00 | 33.20 | 29.20 | 5.00 | 26.48 | 320.50 | 421.00 |
| July | 26.43 | 20-JUL-14:00 | 32.80 | 24.20 | 1.00 | 26.65 | 305.00 | 253.00 |
| August | 28.81 | 14-AUG-16:00 | 32.00 | 28.00 | 1.00 | 25.16 | 107.50 | 223.00 |
| September | 30.06 | 30-SEP-10:00 | 32.80 | 29.40 | 3.00 | 25.66 | 398.00 | 359.50 |
| October | 27.36 | 16-OCT-14:00 | 31.50 | 26.00 | 3.00 | 24.16 | 239.00 | 346.50 |
| November | 27.56 | 10-NOV-12:00 | 31.00 | 26.40 | 6.00 | 28.11 | 388.00 | 95.50 |
| December | 26.86 | 03-DEC-12:00 | 31.50 | 25.30 | 1.00 | 23.49 | 301.00 | 468.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 25.53 | 29.00 | 23.10 | 1.00 | 22.47 | 0.00 | 0.00 | |
| Maximum of Months | 30.11 | 34.20 | 29.40 | 6.00 | 28.11 | 398.00 | 535.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 24.20 | 09-JAN-21:00 | 26.50 | 24.77 | 4.00 | 25.16 | 0.00 | 0.00 |
| February | 24.40 | 15-FEB-18:00 | 28.30 | 25.33 | 4.00 | 20.75 | 0.00 | 0.00 |
| March | 25.30 | 28-MAR-06:00 | 27.20 | 25.72 | 3.00 | 19.87 | 103.00 | 28.00 |
| April | 27.00 | 10-APR-17:00 | 30.50 | 27.87 | 4.50 | 25.00 | 20.00 | 20.50 |
| May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
| June | 29.20 | 15-JUN-09:00 | 33.20 | 30.11 | 5.00 | 26.48 | 320.50 | 421.00 |
| July | 26.00 | 10-JUL-14:00 | 26.50 | 26.11 | 2.30 | 23.49 | 286.00 | 36.50 |
| August | 28.00 | 02-AUG-10:00 | 31.00 | 28.65 | 4.00 | 24.16 | 419.00 | 195.50 |
| September | 29.40 | 30-SEP-10:00 | 32.80 | 30.06 | 3.00 | 25.66 | 398.00 | 359.50 |
| October | 26.50 | 16-OCT-08:00 | 29.00 | 27.04 | 2.50 | 21.78 | 300.00 | 326.00 |
| November | 26.40 | 10-NOV-12:00 | 31.00 | 27.56 | 6.00 | 28.11 | 388.00 | 95.50 |
| December | 26.00 | 10-DEC-17:00 | 29.00 | 26.74 | 3.00 | 21.78 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 24.20 | 26.50 | 24.77 | 2.30 | 19.87 | 0.00 | 0.00 | |
| Maximum of Months | 29.40 | 33.20 | 30.11 | 6.00 | 28.11 | 419.00 | 421.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 29.71 | 38.82 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 29.90 | 44.34 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 30.35 | 50.49 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 30.97 | 51.18 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 31.58 | 43.47 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 32.02 | 46.77 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 32.16 | 39.95 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 31.97 | 43.65 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 31.50 | 40.53 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 30.87 | 37.35 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 30.27 | 35.77 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 29.84 | 36.19 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 30.93 | 42.35 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 29.71 | 35.77 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 32.16 | 51.18 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486029.8 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.4 | 0.00 | 0.00 | 672.00 | 0.00 | -155790894.5 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172494350.6 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166920580.3 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172480586.7 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166919834.8 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481142.9 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481650.5 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442718.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166922731.2 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484093.7 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059295.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166912070.0 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172483068.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494350.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155790894.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486027.0 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.5 | 0.00 | 0.00 | 672.00 | 0.00 | -155790892.0 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172494348.8 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166920579.7 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172480587.0 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166919836.4 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481142.9 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481650.2 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442718.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166922729.9 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484091.5 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059296.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166912066.8 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172483066.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494348.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155790892.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486028.9 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.4 | 0.00 | 0.00 | 672.00 | 0.00 | -155790894.0 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172494351.3 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166920582.6 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172480590.7 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166919839.8 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481145.7 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704878.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481653.5 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442718.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166922732.5 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172484094.3 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059295.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166912070.0 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172483067.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494351.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.3 | 0.00 | 0.00 | 744.00 | 0.00 | -155790894.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486031.9 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.4 | 0.00 | 0.00 | 672.00 | 0.00 | -155790896.4 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172494353.3 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920584.0 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172480592.1 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166919840.8 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481148.0 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704878.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481655.3 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442719.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166922734.3 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172484097.0 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059294.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166912073.6 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172483071.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494353.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.3 | 0.00 | 0.00 | 744.00 | 0.00 | -155790896.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486032.0 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.4 | 0.00 | 0.00 | 672.00 | 0.00 | -155790896.4 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172494353.4 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166920584.1 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172480592.2 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166919840.9 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481148.0 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704878.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481655.4 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442719.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166922734.4 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172484097.1 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059294.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166912073.7 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172483071.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494353.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.3 | 0.00 | 0.00 | 744.00 | 0.00 | -155790896.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486034.5 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.3 | 0.00 | 0.00 | 672.00 | 0.00 | -155790898.5 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172494354.7 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920584.3 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172480591.3 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166919838.8 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481147.5 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704878.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481655.2 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442719.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166922735.2 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484098.9 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059294.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166912076.4 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172483073.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494354.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.3 | 0.00 | 0.00 | 744.00 | 0.00 | -155790898.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486035.0 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735156.2 | 0.00 | 0.00 | 672.00 | 0.00 | -155790898.9 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172494355.3 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166920585.3 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964999.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172480592.9 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166919840.1 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481148.2 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704878.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481656.1 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442719.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166922736.0 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484099.6 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059294.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166912077.1 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459776.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172483073.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.6 | 0.00 | 0.00 | 672.00 | 0.00 | -172494355.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.3 | 0.00 | 0.00 | 744.00 | 0.00 | -155790898.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483873.6 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791020.4 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481541.7 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919038.4 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480217.1 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919213.8 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484562.0 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482195.9 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919878.9 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483098.6 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917203.1 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483054.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484562.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791020.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483871.4 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791018.2 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481540.0 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919037.8 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480217.4 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919215.2 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484561.9 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482195.5 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919877.7 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483096.7 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917200.9 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483052.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484561.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791018.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483875.2 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791022.3 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481544.1 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919041.0 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480220.1 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919216.9 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484564.3 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482198.8 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919881.4 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483101.1 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917205.3 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483056.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484564.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791022.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483873.4 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791020.5 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481543.0 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919041.1 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480221.2 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919219.0 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484565.0 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482199.3 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919880.9 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483099.8 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917203.6 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483054.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484565.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791020.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483875.9 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791022.4 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481544.7 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919042.1 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480222.2 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919219.7 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484567.0 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482200.9 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919882.7 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483102.1 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917206.0 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483058.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484567.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791022.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483876.0 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791022.5 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481544.8 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919042.2 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480222.3 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919219.8 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484567.1 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482201.0 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919882.8 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483102.2 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917206.1 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483058.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484567.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791022.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483878.3 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791024.7 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481546.4 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919042.9 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480222.0 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919218.4 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484567.2 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482201.4 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919884.1 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483104.2 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917208.5 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483060.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484567.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791024.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.145108E+10 | -0.127859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483878.3 | 59.44 | 0.00 | 0.00 |
| February | 0.130326E+10 | -0.114747E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155791024.8 | 59.44 | 0.00 | 0.00 |
| March | 0.142332E+10 | -0.125084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481546.5 | 59.44 | 0.00 | 0.00 |
| April | 0.135158E+10 | -0.118466E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919043.0 | 59.44 | 0.00 | 0.00 |
| May | 0.137041E+10 | -0.119793E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480222.1 | 59.44 | 0.00 | 0.00 |
| June | 0.130807E+10 | -0.114115E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919218.5 | 59.44 | 0.00 | 0.00 |
| July | 0.134557E+10 | -0.117309E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484567.3 | 59.44 | 0.00 | 0.00 |
| August | 0.135389E+10 | -0.118141E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482201.5 | 59.44 | 0.00 | 0.00 |
| September | 0.132981E+10 | -0.116289E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919884.1 | 59.44 | 0.00 | 0.00 |
| October | 0.140095E+10 | -0.122846E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483104.3 | 59.44 | 0.00 | 0.00 |
| November | 0.138102E+10 | -0.121410E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917208.5 | 59.44 | 0.00 | 0.00 |
| December | 0.144540E+10 | -0.127292E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483060.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.164644E+11 | -0.144335E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203084E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.130326E+10 | -0.127859E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172484567.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.145108E+10 | -0.114115E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -155791024.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811780E+09 | -639293075.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172486937.4 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735127.9 | 0.00 | 0.00 | 672.00 | 0.00 | -155790888.6 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403106.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172494339.2 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326476.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166920572.3 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964995.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172480583.3 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575047.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166919828.5 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481136.9 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172481642.9 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442716.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166922725.4 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484087.5 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059297.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166912063.7 | 59.44 | 0.00 | 0.00 |
| December | 0.808946E+09 | -636459712.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172486710.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924760E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293075.1 | 0.00 | 0.00 | 672.00 | 0.00 | -172494339.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811780E+09 | -570575047.6 | 0.00 | 0.00 | 744.00 | 0.00 | -155790888.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811781E+09 | -639293064.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172488077.7 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735103.8 | 0.00 | 0.00 | 672.00 | 0.00 | -155790881.9 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403117.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172494329.8 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326484.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166920569.4 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964992.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172480571.3 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575046.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166919827.8 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481136.7 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172481642.3 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442716.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166922723.6 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484084.8 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059298.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166912059.8 | 59.44 | 0.00 | 0.00 |
| December | 0.808950E+09 | -636459667.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172490252.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924760E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203087E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293064.2 | 0.00 | 0.00 | 672.00 | 0.00 | -172494329.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811781E+09 | -570575046.9 | 0.00 | 0.00 | 744.00 | 0.00 | -155790881.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811780E+09 | -639293076.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172486802.0 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735131.1 | 0.00 | 0.00 | 672.00 | 0.00 | -155790891.9 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403105.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172494343.9 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326475.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920577.0 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964996.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172480588.2 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575047.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166919833.6 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481140.8 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481647.8 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442717.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166922729.0 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484091.6 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059296.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166912068.4 | 59.44 | 0.00 | 0.00 |
| December | 0.808945E+09 | -636459729.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172485681.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924760E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293076.1 | 0.00 | 0.00 | 672.00 | 0.00 | -172494343.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811780E+09 | -570575047.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155790891.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811781E+09 | -639293069.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172487579.3 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735114.4 | 0.00 | 0.00 | 672.00 | 0.00 | -155790886.8 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403112.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172494337.5 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326481.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166920575.5 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964993.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172480586.7 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575046.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166919836.2 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481141.6 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704878.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481648.1 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442718.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166922727.9 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484089.6 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059296.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166912065.2 | 59.44 | 0.00 | 0.00 |
| December | 0.808948E+09 | -636459692.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172488238.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924760E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293069.3 | 0.00 | 0.00 | 672.00 | 0.00 | -172494337.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811781E+09 | -570575046.9 | 0.00 | 0.00 | 744.00 | 0.00 | -155790886.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293074.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172486272.6 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735146.7 | 0.00 | 0.00 | 672.00 | 0.00 | -155790891.5 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403099.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172494345.9 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326471.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166920577.2 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964999.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172480585.8 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166919834.2 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481141.8 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481648.0 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442717.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166922728.5 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484090.4 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059296.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166912066.4 | 59.44 | 0.00 | 0.00 |
| December | 0.808945E+09 | -636459739.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172484984.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924760E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293074.7 | 0.00 | 0.00 | 672.00 | 0.00 | -172494345.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.2 | 0.00 | 0.00 | 744.00 | 0.00 | -155790891.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293074.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172486283.6 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735146.3 | 0.00 | 0.00 | 672.00 | 0.00 | -155790891.6 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403099.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172494346.0 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326471.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166920577.4 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598964998.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172480586.1 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166919834.5 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481142.1 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481648.3 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442717.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166922728.7 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484090.6 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059296.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166912066.6 | 59.44 | 0.00 | 0.00 |
| December | 0.808945E+09 | -636459740.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172484966.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924760E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293074.8 | 0.00 | 0.00 | 672.00 | 0.00 | -172494346.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.2 | 0.00 | 0.00 | 744.00 | 0.00 | -155790891.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172486049.9 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735155.7 | 0.00 | 0.00 | 672.00 | 0.00 | -155790895.4 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403095.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172494349.9 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920578.3 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172480583.8 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166919832.0 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481141.4 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172481648.0 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442717.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166922729.8 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484092.6 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059296.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166912069.8 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459766.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172483604.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.9 | 0.00 | 0.00 | 672.00 | 0.00 | -172494349.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155790895.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.811779E+09 | -639293071.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172486054.0 | 59.44 | 0.00 | 0.00 |
| February | 0.729526E+09 | -573735155.5 | 0.00 | 0.00 | 672.00 | 0.00 | -155790895.6 | 59.44 | 0.00 | 0.00 |
| March | 0.797897E+09 | -625403096.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172494350.0 | 59.44 | 0.00 | 0.00 |
| April | 0.759247E+09 | -592326468.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920578.6 | 59.44 | 0.00 | 0.00 |
| May | 0.771446E+09 | -598965000.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172480584.1 | 59.44 | 0.00 | 0.00 |
| June | 0.737495E+09 | -570575048.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166919832.3 | 59.44 | 0.00 | 0.00 |
| July | 0.759025E+09 | -586544266.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481141.7 | 59.44 | 0.00 | 0.00 |
| August | 0.763187E+09 | -590704879.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172481648.3 | 59.44 | 0.00 | 0.00 |
| September | 0.748365E+09 | -581442717.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166922729.9 | 59.44 | 0.00 | 0.00 |
| October | 0.786711E+09 | -614227387.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484092.9 | 59.44 | 0.00 | 0.00 |
| November | 0.773971E+09 | -607059295.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166912070.1 | 59.44 | 0.00 | 0.00 |
| December | 0.808943E+09 | -636459766.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172483604.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924759E+10 | -0.721674E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.729526E+09 | -639293071.9 | 0.00 | 0.00 | 672.00 | 0.00 | -172494350.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.811779E+09 | -570575048.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155790895.6 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 350.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 321.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 361.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 358.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 376.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 370.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 383.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 369.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 357.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 356.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 337.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 349.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4292.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 321.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 383.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.574906E+10 | 0.434863E+10 | 3414.27 | 05-JAN-15:00 | 2932.36 | 0.00 |
| February | 0.00 | 0.00 | 0.550104E+10 | 0.415865E+10 | 3673.29 | 28-FEB-15:10 | 2955.42 | 0.00 |
| March | 0.00 | 0.00 | 0.633116E+10 | 0.460634E+10 | 4009.66 | 19-MAR-16:10 | 3116.99 | 0.00 |
| April | 0.00 | 0.00 | 0.655857E+10 | 0.447647E+10 | 4004.16 | 02-APR-16:10 | 2854.09 | 0.00 |
| May | 0.00 | 0.00 | 0.722474E+10 | 0.462456E+10 | 4206.90 | 06-MAY-16:02 | 3012.88 | 0.00 |
| June | 0.00 | 0.00 | 0.707379E+10 | 0.454340E+10 | 4124.34 | 13-JUN-16:01 | 2875.72 | 0.00 |
| July | 0.00 | 0.00 | 0.602076E+10 | 0.417647E+10 | 3517.37 | 04-JUL-16:10 | 2555.21 | 0.00 |
| August | 0.00 | 0.00 | 0.665594E+10 | 0.420971E+10 | 3956.51 | 12-AUG-16:03 | 2582.31 | 0.00 |
| September | 0.00 | 0.00 | 0.629234E+10 | 0.414313E+10 | 3811.89 | 04-SEP-16:03 | 2646.58 | 0.00 |
| October | 0.00 | 0.00 | 0.616021E+10 | 0.407979E+10 | 3778.73 | 29-OCT-13:30 | 2598.43 | 0.00 |
| November | 0.00 | 0.00 | 0.586750E+10 | 0.410801E+10 | 3629.87 | 04-NOV-15:20 | 2656.16 | 0.00 |
| December | 0.00 | 0.00 | 0.574316E+10 | 0.422879E+10 | 3416.46 | 30-DEC-16:10 | 2556.09 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.751783E+11 | 0.517039E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.550104E+10 | 0.407979E+10 | 3414.27 | 2555.21 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.722474E+10 | 0.462456E+10 | 4206.90 | 3116.99 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.497449E+10 | 0.365756E+10 | 2856.94 | 04-JAN-16:10 | 2220.79 | 0.00 |
| February | 0.00 | 0.00 | 0.492817E+10 | 0.364460E+10 | 3270.57 | 28-FEB-15:10 | 2566.39 | 0.00 |
| March | 0.00 | 0.00 | 0.606237E+10 | 0.436671E+10 | 3714.11 | 19-MAR-16:10 | 2871.08 | 0.00 |
| April | 0.00 | 0.00 | 0.661254E+10 | 0.452568E+10 | 3909.45 | 29-APR-16:15 | 2688.04 | 0.00 |
| May | 0.00 | 0.00 | 0.749630E+10 | 0.485998E+10 | 4379.28 | 06-MAY-15:10 | 3248.87 | 0.00 |
| June | 0.00 | 0.00 | 0.754347E+10 | 0.495110E+10 | 4535.91 | 16-JUN-15:30 | 3131.66 | 0.00 |
| July | 0.00 | 0.00 | 0.629752E+10 | 0.442228E+10 | 3717.48 | 04-JUL-16:10 | 2756.91 | 0.00 |
| August | 0.00 | 0.00 | 0.682422E+10 | 0.435192E+10 | 4011.29 | 12-AUG-15:20 | 2590.77 | 0.00 |
| September | 0.00 | 0.00 | 0.623667E+10 | 0.409672E+10 | 3730.70 | 04-SEP-16:03 | 2600.21 | 0.00 |
| October | 0.00 | 0.00 | 0.587446E+10 | 0.383536E+10 | 3489.52 | 04-OCT-16:03 | 2491.60 | 0.00 |
| November | 0.00 | 0.00 | 0.532004E+10 | 0.362927E+10 | 3179.96 | 10-NOV-13:30 | 2014.00 | 0.00 |
| December | 0.00 | 0.00 | 0.495903E+10 | 0.353504E+10 | 2906.63 | 30-DEC-16:10 | 2087.55 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.731293E+11 | 0.498762E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.492817E+10 | 0.353504E+10 | 2856.94 | 2014.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.754347E+10 | 0.495110E+10 | 4535.91 | 3248.87 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.385692E+10 | 0.304760E+10 | 8534.86 | 09-JAN-07:03 | 4686.80 | 0.00 |
| February | 0.00 | 0.00 | 0.379584E+10 | 0.299038E+10 | 8534.86 | 06-FEB-07:03 | 5245.96 | 0.00 |
| March | 0.00 | 0.00 | 0.448673E+10 | 0.342601E+10 | 8534.00 | 15-MAR-07:02 | 4505.77 | 0.00 |
| April | 0.00 | 0.00 | 0.436150E+10 | 0.309743E+10 | 8531.38 | 24-APR-06:03 | 4507.00 | 0.00 |
| May | 0.00 | 0.00 | 0.516977E+10 | 0.340278E+10 | 8534.00 | 17-MAY-07:02 | 4062.73 | 0.00 |
| June | 0.00 | 0.00 | 0.506951E+10 | 0.336003E+10 | 8533.78 | 26-JUN-06:03 | 4374.44 | 0.00 |
| July | 0.00 | 0.00 | 0.394771E+10 | 0.281303E+10 | 8534.00 | 12-JUL-07:02 | 4555.95 | 0.00 |
| August | 0.00 | 0.00 | 0.477639E+10 | 0.312532E+10 | 8530.09 | 29-AUG-06:03 | 3757.15 | 0.00 |
| September | 0.00 | 0.00 | 0.425551E+10 | 0.286003E+10 | 8535.05 | 18-SEP-07:02 | 4243.28 | 0.00 |
| October | 0.00 | 0.00 | 0.421105E+10 | 0.286275E+10 | 8535.05 | 23-OCT-07:02 | 4510.35 | 0.00 |
| November | 0.00 | 0.00 | 0.399038E+10 | 0.288490E+10 | 8535.00 | 06-NOV-07:03 | 5139.71 | 0.00 |
| December | 0.00 | 0.00 | 0.372214E+10 | 0.288733E+10 | 8535.05 | 26-DEC-07:03 | 5172.50 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.516434E+11 | 0.367576E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.372214E+10 | 0.281303E+10 | 8530.09 | 3757.15 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.516977E+10 | 0.342601E+10 | 8535.05 | 5245.96 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.498134E+10 | 0.365057E+10 | 2787.79 | 04-JAN-13:00 | 2236.66 | 0.00 |
| February | 0.00 | 0.00 | 0.494424E+10 | 0.364764E+10 | 3066.55 | 28-FEB-15:10 | 2390.01 | 0.00 |
| March | 0.00 | 0.00 | 0.605191E+10 | 0.434582E+10 | 3444.85 | 19-MAR-16:10 | 2622.70 | 0.00 |
| April | 0.00 | 0.00 | 0.662551E+10 | 0.452643E+10 | 3618.37 | 30-APR-16:20 | 2467.10 | 0.00 |
| May | 0.00 | 0.00 | 0.752371E+10 | 0.487355E+10 | 4135.69 | 06-MAY-15:10 | 3040.23 | 0.00 |
| June | 0.00 | 0.00 | 0.757272E+10 | 0.496601E+10 | 4317.05 | 15-JUN-10:30 | 2739.46 | 0.00 |
| July | 0.00 | 0.00 | 0.631746E+10 | 0.442859E+10 | 3390.82 | 28-JUL-13:00 | 2420.81 | 0.00 |
| August | 0.00 | 0.00 | 0.685693E+10 | 0.436934E+10 | 3810.12 | 01-AUG-15:10 | 2557.49 | 0.00 |
| September | 0.00 | 0.00 | 0.627053E+10 | 0.411668E+10 | 3514.59 | 02-SEP-14:10 | 2401.84 | 0.00 |
| October | 0.00 | 0.00 | 0.588610E+10 | 0.383597E+10 | 3310.11 | 29-OCT-13:00 | 2221.56 | 0.00 |
| November | 0.00 | 0.00 | 0.533714E+10 | 0.363390E+10 | 3193.33 | 10-NOV-13:30 | 2036.78 | 0.00 |
| December | 0.00 | 0.00 | 0.496883E+10 | 0.353167E+10 | 2860.36 | 09-DEC-14:00 | 2033.24 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.733364E+11 | 0.499262E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.494424E+10 | 0.353167E+10 | 2787.79 | 2033.24 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.757272E+10 | 0.496601E+10 | 4317.05 | 3040.23 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.430857E+10 | 0.311165E+10 | 2325.44 | 11-JAN-17:10 | 1615.99 | 0.00 |
| February | 0.00 | 0.00 | 0.421362E+10 | 0.305670E+10 | 2461.98 | 13-FEB-16:10 | 1765.62 | 0.00 |
| March | 0.00 | 0.00 | 0.508436E+10 | 0.359910E+10 | 2747.62 | 19-MAR-16:10 | 2092.40 | 0.00 |
| April | 0.00 | 0.00 | 0.559424E+10 | 0.374546E+10 | 2984.02 | 29-APR-16:15 | 1982.65 | 0.00 |
| May | 0.00 | 0.00 | 0.644842E+10 | 0.410697E+10 | 3324.74 | 06-MAY-15:10 | 2420.65 | 0.00 |
| June | 0.00 | 0.00 | 0.647706E+10 | 0.417484E+10 | 3568.40 | 13-JUN-16:01 | 2469.66 | 0.00 |
| July | 0.00 | 0.00 | 0.546983E+10 | 0.377187E+10 | 2848.13 | 04-JUL-16:10 | 2073.22 | 0.00 |
| August | 0.00 | 0.00 | 0.586998E+10 | 0.367989E+10 | 3137.25 | 12-AUG-17:00 | 2019.84 | 0.00 |
| September | 0.00 | 0.00 | 0.539067E+10 | 0.345879E+10 | 2886.39 | 04-SEP-16:03 | 1932.12 | 0.00 |
| October | 0.00 | 0.00 | 0.514299E+10 | 0.329188E+10 | 2635.09 | 29-OCT-13:00 | 1749.78 | 0.00 |
| November | 0.00 | 0.00 | 0.466481E+10 | 0.311860E+10 | 2584.09 | 10-NOV-13:30 | 1626.84 | 0.00 |
| December | 0.00 | 0.00 | 0.433724E+10 | 0.303151E+10 | 2364.15 | 10-DEC-18:30 | 1535.78 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.630018E+11 | 0.421473E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.421362E+10 | 0.303151E+10 | 2325.44 | 1535.78 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.647706E+10 | 0.417484E+10 | 3568.40 | 2469.66 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.430898E+10 | 0.311181E+10 | 2323.50 | 11-JAN-17:10 | 1614.25 | 0.00 |
| February | 0.00 | 0.00 | 0.421423E+10 | 0.305708E+10 | 2459.55 | 13-FEB-16:10 | 1763.74 | 0.00 |
| March | 0.00 | 0.00 | 0.508397E+10 | 0.359863E+10 | 2743.21 | 19-MAR-16:10 | 2088.59 | 0.00 |
| April | 0.00 | 0.00 | 0.559467E+10 | 0.374569E+10 | 2979.34 | 29-APR-16:15 | 1979.01 | 0.00 |
| May | 0.00 | 0.00 | 0.644934E+10 | 0.410762E+10 | 3323.17 | 06-MAY-15:10 | 2419.57 | 0.00 |
| June | 0.00 | 0.00 | 0.647807E+10 | 0.417555E+10 | 3564.15 | 13-JUN-16:01 | 2466.14 | 0.00 |
| July | 0.00 | 0.00 | 0.547060E+10 | 0.377236E+10 | 2842.75 | 04-JUL-16:10 | 2068.68 | 0.00 |
| August | 0.00 | 0.00 | 0.587120E+10 | 0.368075E+10 | 3130.93 | 12-AUG-17:00 | 2014.56 | 0.00 |
| September | 0.00 | 0.00 | 0.539205E+10 | 0.345981E+10 | 2883.78 | 04-SEP-16:03 | 1930.28 | 0.00 |
| October | 0.00 | 0.00 | 0.514330E+10 | 0.329200E+10 | 2635.83 | 29-OCT-13:00 | 1750.62 | 0.00 |
| November | 0.00 | 0.00 | 0.466549E+10 | 0.311902E+10 | 2587.13 | 10-NOV-13:30 | 1629.58 | 0.00 |
| December | 0.00 | 0.00 | 0.433761E+10 | 0.303166E+10 | 2362.20 | 10-DEC-18:30 | 1533.94 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.630095E+11 | 0.421520E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.421423E+10 | 0.303166E+10 | 2323.50 | 1533.94 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.647807E+10 | 0.417555E+10 | 3564.15 | 2466.14 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.512408E+10 | 0.382820E+10 | 2888.86 | 04-JAN-13:00 | 2380.56 | 0.00 |
| February | 0.00 | 0.00 | 0.482114E+10 | 0.359220E+10 | 2861.97 | 28-FEB-15:00 | 2284.42 | 0.00 |
| March | 0.00 | 0.00 | 0.538122E+10 | 0.385643E+10 | 3048.04 | 19-MAR-16:10 | 2340.74 | 0.00 |
| April | 0.00 | 0.00 | 0.555933E+10 | 0.370934E+10 | 3035.64 | 02-APR-16:10 | 2088.43 | 0.00 |
| May | 0.00 | 0.00 | 0.619075E+10 | 0.388210E+10 | 3165.55 | 06-MAY-16:10 | 2198.05 | 0.00 |
| June | 0.00 | 0.00 | 0.601427E+10 | 0.377412E+10 | 3197.78 | 11-JUN-16:02 | 2122.87 | 0.00 |
| July | 0.00 | 0.00 | 0.520528E+10 | 0.353561E+10 | 2662.30 | 15-JUL-16:15 | 1948.87 | 0.00 |
| August | 0.00 | 0.00 | 0.571715E+10 | 0.354841E+10 | 3084.28 | 12-AUG-17:00 | 1949.17 | 0.00 |
| September | 0.00 | 0.00 | 0.546725E+10 | 0.351857E+10 | 2985.57 | 24-SEP-16:03 | 1918.01 | 0.00 |
| October | 0.00 | 0.00 | 0.545763E+10 | 0.355400E+10 | 3085.67 | 29-OCT-13:00 | 2128.43 | 0.00 |
| November | 0.00 | 0.00 | 0.524794E+10 | 0.361885E+10 | 2984.89 | 18-NOV-13:00 | 2287.74 | 0.00 |
| December | 0.00 | 0.00 | 0.516260E+10 | 0.375023E+10 | 2895.67 | 31-DEC-13:00 | 2220.39 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.653486E+11 | 0.441681E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.482114E+10 | 0.351857E+10 | 2662.30 | 1918.01 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.619075E+10 | 0.388210E+10 | 3197.78 | 2380.56 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.550412E+10 | 0.416540E+10 | 3004.75 | 04-JAN-13:00 | 2493.58 | 0.00 |
| February | 0.00 | 0.00 | 0.515913E+10 | 0.389367E+10 | 2982.13 | 04-FEB-15:10 | 2356.20 | 0.00 |
| March | 0.00 | 0.00 | 0.574473E+10 | 0.417442E+10 | 3230.44 | 19-MAR-16:10 | 2506.28 | 0.00 |
| April | 0.00 | 0.00 | 0.593707E+10 | 0.403467E+10 | 3219.50 | 02-APR-16:10 | 2252.22 | 0.00 |
| May | 0.00 | 0.00 | 0.658693E+10 | 0.421789E+10 | 3337.91 | 07-MAY-16:10 | 2245.74 | 0.00 |
| June | 0.00 | 0.00 | 0.639363E+10 | 0.409585E+10 | 3384.60 | 11-JUN-16:02 | 2290.68 | 0.00 |
| July | 0.00 | 0.00 | 0.558925E+10 | 0.386728E+10 | 2844.50 | 30-JUL-16:03 | 2036.80 | 0.00 |
| August | 0.00 | 0.00 | 0.609021E+10 | 0.386079E+10 | 3241.32 | 12-AUG-17:00 | 2087.44 | 0.00 |
| September | 0.00 | 0.00 | 0.583960E+10 | 0.383617E+10 | 3167.54 | 04-SEP-16:03 | 2160.22 | 0.00 |
| October | 0.00 | 0.00 | 0.583863E+10 | 0.387897E+10 | 3269.32 | 29-OCT-13:00 | 2292.50 | 0.00 |
| November | 0.00 | 0.00 | 0.561259E+10 | 0.393606E+10 | 3130.75 | 18-NOV-13:00 | 2427.96 | 0.00 |
| December | 0.00 | 0.00 | 0.552170E+10 | 0.406565E+10 | 3075.80 | 31-DEC-13:00 | 2389.79 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.698176E+11 | 0.480268E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.515913E+10 | 0.383617E+10 | 2844.50 | 2036.80 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.658693E+10 | 0.421789E+10 | 3384.60 | 2506.28 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.115873E+11 | 0.867084E+10 | 7457.65 | 05-JAN-15:00 | 6380.68 | 0.00 |
| February | 0.00 | 0.00 | 0.111131E+11 | 0.829878E+10 | 8086.69 | 28-FEB-15:10 | 6435.06 | 0.00 |
| March | 0.00 | 0.00 | 0.129927E+11 | 0.929303E+10 | 8925.55 | 19-MAR-16:10 | 6829.27 | 0.00 |
| April | 0.00 | 0.00 | 0.134018E+11 | 0.895938E+10 | 8769.72 | 02-APR-16:10 | 6164.65 | 0.00 |
| May | 0.00 | 0.00 | 0.146659E+11 | 0.911462E+10 | 9252.35 | 06-MAY-15:20 | 6632.91 | 0.00 |
| June | 0.00 | 0.00 | 0.142277E+11 | 0.884556E+10 | 9080.22 | 16-JUN-15:30 | 5922.73 | 0.00 |
| July | 0.00 | 0.00 | 0.118033E+11 | 0.798228E+10 | 7614.13 | 04-JUL-16:10 | 5422.74 | 0.00 |
| August | 0.00 | 0.00 | 0.132672E+11 | 0.809185E+10 | 8512.40 | 12-AUG-15:20 | 5282.35 | 0.00 |
| September | 0.00 | 0.00 | 0.124378E+11 | 0.796126E+10 | 8149.13 | 04-SEP-16:03 | 5563.48 | 0.00 |
| October | 0.00 | 0.00 | 0.123871E+11 | 0.803124E+10 | 8357.62 | 29-OCT-13:30 | 5608.36 | 0.00 |
| November | 0.00 | 0.00 | 0.117367E+11 | 0.808225E+10 | 7921.77 | 04-NOV-15:20 | 5728.86 | 0.00 |
| December | 0.00 | 0.00 | 0.114505E+11 | 0.832848E+10 | 7367.94 | 30-DEC-16:10 | 5452.60 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.151071E+12 | 0.101660E+12 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.111131E+11 | 0.796126E+10 | 7367.94 | 5282.35 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.146659E+11 | 0.929303E+10 | 9252.35 | 6829.27 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.991395E+10 | 0.718695E+10 | 6127.80 | 30-JAN-16:20 | 4547.25 | 0.00 |
| February | 0.00 | 0.00 | 0.988768E+10 | 0.720607E+10 | 7150.02 | 28-FEB-15:10 | 5537.80 | 0.00 |
| March | 0.00 | 0.00 | 0.124116E+11 | 0.877897E+10 | 8245.43 | 19-MAR-16:10 | 6260.80 | 0.00 |
| April | 0.00 | 0.00 | 0.134869E+11 | 0.903563E+10 | 8520.25 | 29-APR-16:15 | 5743.91 | 0.00 |
| May | 0.00 | 0.00 | 0.152111E+11 | 0.957831E+10 | 9609.36 | 06-MAY-15:10 | 6986.14 | 0.00 |
| June | 0.00 | 0.00 | 0.151916E+11 | 0.966590E+10 | 10056.04 | 16-JUN-15:30 | 6732.87 | 0.00 |
| July | 0.00 | 0.00 | 0.123538E+11 | 0.846124E+10 | 8082.59 | 04-JUL-16:10 | 5879.30 | 0.00 |
| August | 0.00 | 0.00 | 0.135930E+11 | 0.835948E+10 | 8659.43 | 01-AUG-15:10 | 5704.56 | 0.00 |
| September | 0.00 | 0.00 | 0.122872E+11 | 0.783544E+10 | 7946.93 | 04-SEP-16:03 | 5435.30 | 0.00 |
| October | 0.00 | 0.00 | 0.117530E+11 | 0.749420E+10 | 7617.88 | 04-OCT-16:03 | 5357.31 | 0.00 |
| November | 0.00 | 0.00 | 0.105492E+11 | 0.705288E+10 | 6866.08 | 10-NOV-13:30 | 4215.62 | 0.00 |
| December | 0.00 | 0.00 | 0.975786E+10 | 0.684122E+10 | 6176.11 | 30-DEC-16:10 | 4367.51 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.146397E+12 | 0.974963E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.975786E+10 | 0.684122E+10 | 6127.80 | 4215.62 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.152111E+11 | 0.966590E+10 | 10056.04 | 6986.14 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.116090E+11 | 0.865154E+10 | 7525.61 | 04-JAN-13:00 | 6212.61 | 0.00 |
| February | 0.00 | 0.00 | 0.111581E+11 | 0.830599E+10 | 7532.56 | 28-FEB-15:00 | 5967.21 | 0.00 |
| March | 0.00 | 0.00 | 0.129771E+11 | 0.924395E+10 | 8226.83 | 19-MAR-16:10 | 6177.92 | 0.00 |
| April | 0.00 | 0.00 | 0.134377E+11 | 0.895944E+10 | 7805.55 | 02-APR-16:10 | 5325.04 | 0.00 |
| May | 0.00 | 0.00 | 0.147351E+11 | 0.914411E+10 | 8527.65 | 06-MAY-15:10 | 6058.02 | 0.00 |
| June | 0.00 | 0.00 | 0.143049E+11 | 0.888144E+10 | 8521.73 | 11-JUN-10:00 | 5201.93 | 0.00 |
| July | 0.00 | 0.00 | 0.118586E+11 | 0.799812E+10 | 6809.81 | 01-JUL-13:00 | 4791.12 | 0.00 |
| August | 0.00 | 0.00 | 0.133510E+11 | 0.813191E+10 | 8029.48 | 12-AUG-12:00 | 4812.36 | 0.00 |
| September | 0.00 | 0.00 | 0.125194E+11 | 0.800393E+10 | 7692.51 | 25-SEP-12:00 | 4730.70 | 0.00 |
| October | 0.00 | 0.00 | 0.124231E+11 | 0.803419E+10 | 8278.96 | 29-OCT-13:00 | 5589.67 | 0.00 |
| November | 0.00 | 0.00 | 0.117793E+11 | 0.808913E+10 | 7484.73 | 10-NOV-13:20 | 4793.33 | 0.00 |
| December | 0.00 | 0.00 | 0.114810E+11 | 0.831995E+10 | 7231.40 | 31-DEC-13:00 | 5590.85 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.151634E+12 | 0.101764E+12 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.111581E+11 | 0.799812E+10 | 6809.81 | 4730.70 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.147351E+11 | 0.924395E+10 | 8527.65 | 6212.61 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.992875E+10 | 0.716933E+10 | 5922.67 | 04-JAN-13:00 | 4697.36 | 0.00 |
| February | 0.00 | 0.00 | 0.992588E+10 | 0.721406E+10 | 6583.19 | 28-FEB-15:00 | 5071.38 | 0.00 |
| March | 0.00 | 0.00 | 0.123860E+11 | 0.873043E+10 | 7547.79 | 19-MAR-16:10 | 5621.44 | 0.00 |
| April | 0.00 | 0.00 | 0.135136E+11 | 0.903556E+10 | 7728.87 | 30-APR-16:10 | 5170.93 | 0.00 |
| May | 0.00 | 0.00 | 0.152709E+11 | 0.960743E+10 | 8910.68 | 06-MAY-15:10 | 6393.59 | 0.00 |
| June | 0.00 | 0.00 | 0.152595E+11 | 0.970125E+10 | 9272.15 | 16-JUN-15:30 | 6096.79 | 0.00 |
| July | 0.00 | 0.00 | 0.124000E+11 | 0.847656E+10 | 7170.67 | 04-JUL-16:10 | 5090.03 | 0.00 |
| August | 0.00 | 0.00 | 0.136682E+11 | 0.839952E+10 | 8135.60 | 01-AUG-15:10 | 5297.60 | 0.00 |
| September | 0.00 | 0.00 | 0.123610E+11 | 0.787841E+10 | 7488.82 | 25-SEP-12:00 | 4545.23 | 0.00 |
| October | 0.00 | 0.00 | 0.117812E+11 | 0.749771E+10 | 7224.86 | 29-OCT-13:00 | 4711.56 | 0.00 |
| November | 0.00 | 0.00 | 0.105850E+11 | 0.706085E+10 | 6865.45 | 10-NOV-13:30 | 4244.88 | 0.00 |
| December | 0.00 | 0.00 | 0.978192E+10 | 0.683411E+10 | 6071.95 | 09-DEC-14:00 | 4209.80 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.146862E+12 | 0.976052E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.978192E+10 | 0.683411E+10 | 5922.67 | 4209.80 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.152709E+11 | 0.970125E+10 | 9272.15 | 6393.59 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.848841E+10 | 0.605621E+10 | 4784.23 | 11-JAN-17:10 | 3263.34 | 0.00 |
| February | 0.00 | 0.00 | 0.832906E+10 | 0.596632E+10 | 5095.44 | 28-FEB-15:10 | 3873.79 | 0.00 |
| March | 0.00 | 0.00 | 0.101925E+11 | 0.710181E+10 | 5831.50 | 19-MAR-16:10 | 4362.87 | 0.00 |
| April | 0.00 | 0.00 | 0.111803E+11 | 0.734687E+10 | 6217.58 | 29-APR-16:15 | 4042.28 | 0.00 |
| May | 0.00 | 0.00 | 0.128583E+11 | 0.799068E+10 | 6963.77 | 06-MAY-15:10 | 4970.56 | 0.00 |
| June | 0.00 | 0.00 | 0.128439E+11 | 0.806676E+10 | 7373.37 | 13-JUN-16:03 | 5008.12 | 0.00 |
| July | 0.00 | 0.00 | 0.106545E+11 | 0.720014E+10 | 5926.48 | 04-JUL-16:10 | 4230.84 | 0.00 |
| August | 0.00 | 0.00 | 0.115590E+11 | 0.703483E+10 | 6493.56 | 09-AUG-16:10 | 4190.38 | 0.00 |
| September | 0.00 | 0.00 | 0.105257E+11 | 0.658968E+10 | 5866.79 | 04-SEP-16:03 | 3840.28 | 0.00 |
| October | 0.00 | 0.00 | 0.101745E+11 | 0.638772E+10 | 5570.85 | 29-OCT-13:00 | 3610.51 | 0.00 |
| November | 0.00 | 0.00 | 0.916773E+10 | 0.602763E+10 | 5399.23 | 10-NOV-13:30 | 3313.87 | 0.00 |
| December | 0.00 | 0.00 | 0.848068E+10 | 0.584511E+10 | 4848.78 | 09-DEC-14:00 | 3350.29 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.124455E+12 | 0.816138E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.832906E+10 | 0.584511E+10 | 4784.23 | 3263.34 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.128583E+11 | 0.806676E+10 | 7373.37 | 5008.12 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.848924E+10 | 0.605654E+10 | 4779.99 | 11-JAN-17:10 | 3259.60 | 0.00 |
| February | 0.00 | 0.00 | 0.833052E+10 | 0.596723E+10 | 5093.04 | 28-FEB-15:10 | 3872.36 | 0.00 |
| March | 0.00 | 0.00 | 0.101918E+11 | 0.710092E+10 | 5821.09 | 19-MAR-16:10 | 4353.96 | 0.00 |
| April | 0.00 | 0.00 | 0.111812E+11 | 0.734740E+10 | 6206.25 | 29-APR-16:15 | 4033.65 | 0.00 |
| May | 0.00 | 0.00 | 0.128602E+11 | 0.799199E+10 | 6959.40 | 06-MAY-15:10 | 4967.52 | 0.00 |
| June | 0.00 | 0.00 | 0.128460E+11 | 0.806827E+10 | 7363.77 | 13-JUN-16:03 | 5000.35 | 0.00 |
| July | 0.00 | 0.00 | 0.106561E+11 | 0.720112E+10 | 5913.34 | 04-JUL-16:10 | 4219.92 | 0.00 |
| August | 0.00 | 0.00 | 0.115616E+11 | 0.703658E+10 | 6487.87 | 09-AUG-16:10 | 4185.97 | 0.00 |
| September | 0.00 | 0.00 | 0.105284E+11 | 0.659163E+10 | 5859.44 | 04-SEP-16:03 | 3835.05 | 0.00 |
| October | 0.00 | 0.00 | 0.101754E+11 | 0.638811E+10 | 5573.73 | 29-OCT-13:00 | 3613.39 | 0.00 |
| November | 0.00 | 0.00 | 0.916904E+10 | 0.602839E+10 | 5405.91 | 10-NOV-13:30 | 3319.82 | 0.00 |
| December | 0.00 | 0.00 | 0.848158E+10 | 0.584553E+10 | 4848.95 | 09-DEC-14:00 | 3350.57 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.124471E+12 | 0.816237E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.833052E+10 | 0.584553E+10 | 4779.99 | 3259.60 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.128602E+11 | 0.806827E+10 | 7363.77 | 5000.35 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.101873E+11 | 0.754902E+10 | 6182.23 | 04-JAN-13:00 | 5080.35 | 0.00 |
| February | 0.00 | 0.00 | 0.957623E+10 | 0.706574E+10 | 6033.86 | 28-FEB-15:00 | 4772.98 | 0.00 |
| March | 0.00 | 0.00 | 0.107856E+11 | 0.761846E+10 | 6499.59 | 19-MAR-16:10 | 4918.74 | 0.00 |
| April | 0.00 | 0.00 | 0.110965E+11 | 0.726956E+10 | 6322.07 | 02-APR-16:10 | 4279.56 | 0.00 |
| May | 0.00 | 0.00 | 0.123073E+11 | 0.752327E+10 | 6576.81 | 06-MAY-15:10 | 4634.34 | 0.00 |
| June | 0.00 | 0.00 | 0.118667E+11 | 0.724017E+10 | 6531.65 | 11-JUN-16:02 | 4240.39 | 0.00 |
| July | 0.00 | 0.00 | 0.100970E+11 | 0.671640E+10 | 5455.91 | 04-JUL-16:10 | 3786.90 | 0.00 |
| August | 0.00 | 0.00 | 0.112308E+11 | 0.676408E+10 | 6332.49 | 12-AUG-12:00 | 3758.40 | 0.00 |
| September | 0.00 | 0.00 | 0.106806E+11 | 0.671456E+10 | 6183.42 | 24-SEP-16:03 | 3885.04 | 0.00 |
| October | 0.00 | 0.00 | 0.108216E+11 | 0.692748E+10 | 6612.91 | 29-OCT-13:00 | 4482.86 | 0.00 |
| November | 0.00 | 0.00 | 0.103770E+11 | 0.706353E+10 | 6302.30 | 18-NOV-13:00 | 4832.40 | 0.00 |
| December | 0.00 | 0.00 | 0.102003E+11 | 0.734208E+10 | 6071.71 | 31-DEC-13:00 | 4640.12 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.129227E+12 | 0.857944E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.957623E+10 | 0.671456E+10 | 5455.91 | 3758.40 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.123073E+11 | 0.761846E+10 | 6612.91 | 5080.35 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.101880E+11 | 0.754921E+10 | 6191.09 | 04-JAN-13:00 | 5088.96 | 0.00 |
| February | 0.00 | 0.00 | 0.957753E+10 | 0.706653E+10 | 6032.30 | 28-FEB-15:00 | 4772.11 | 0.00 |
| March | 0.00 | 0.00 | 0.107848E+11 | 0.761752E+10 | 6488.96 | 19-MAR-16:10 | 4909.46 | 0.00 |
| April | 0.00 | 0.00 | 0.110975E+11 | 0.727007E+10 | 6309.12 | 02-APR-16:10 | 4269.09 | 0.00 |
| May | 0.00 | 0.00 | 0.123092E+11 | 0.752459E+10 | 6572.52 | 06-MAY-15:10 | 4631.43 | 0.00 |
| June | 0.00 | 0.00 | 0.118690E+11 | 0.724172E+10 | 6521.85 | 11-JUN-16:02 | 4232.76 | 0.00 |
| July | 0.00 | 0.00 | 0.100986E+11 | 0.671740E+10 | 5442.59 | 04-JUL-16:10 | 3776.12 | 0.00 |
| August | 0.00 | 0.00 | 0.112334E+11 | 0.676584E+10 | 6336.17 | 12-AUG-12:00 | 3761.36 | 0.00 |
| September | 0.00 | 0.00 | 0.106833E+11 | 0.671648E+10 | 6176.84 | 24-SEP-16:03 | 3880.43 | 0.00 |
| October | 0.00 | 0.00 | 0.108225E+11 | 0.692782E+10 | 6615.72 | 29-OCT-13:00 | 4485.69 | 0.00 |
| November | 0.00 | 0.00 | 0.103782E+11 | 0.706419E+10 | 6306.03 | 18-NOV-13:00 | 4836.37 | 0.00 |
| December | 0.00 | 0.00 | 0.102011E+11 | 0.734236E+10 | 6079.23 | 31-DEC-13:00 | 4647.41 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.129243E+12 | 0.858037E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.957753E+10 | 0.671648E+10 | 5442.59 | 3761.36 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.123092E+11 | 0.761752E+10 | 6615.72 | 5088.96 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.627364E+10 | 0.475460E+10 | 4884.29 | 05-JAN-15:00 | 4256.29 | 0.00 |
| February | 0.00 | 0.00 | 0.610456E+10 | 0.461074E+10 | 5317.46 | 28-FEB-15:10 | 4321.08 | 0.00 |
| March | 0.00 | 0.00 | 0.731888E+10 | 0.529971E+10 | 5840.82 | 19-MAR-16:10 | 4544.65 | 0.00 |
| April | 0.00 | 0.00 | 0.762653E+10 | 0.518156E+10 | 5656.72 | 02-APR-16:10 | 4116.34 | 0.00 |
| May | 0.00 | 0.00 | 0.829475E+10 | 0.523158E+10 | 6075.66 | 06-MAY-15:20 | 4482.97 | 0.00 |
| June | 0.00 | 0.00 | 0.808187E+10 | 0.510372E+10 | 5904.89 | 16-JUN-15:30 | 3960.40 | 0.00 |
| July | 0.00 | 0.00 | 0.656471E+10 | 0.449355E+10 | 4904.85 | 04-JUL-16:10 | 3585.05 | 0.00 |
| August | 0.00 | 0.00 | 0.737184E+10 | 0.453132E+10 | 5449.56 | 12-AUG-15:20 | 3518.17 | 0.00 |
| September | 0.00 | 0.00 | 0.692396E+10 | 0.449644E+10 | 5389.17 | 10-SEP-15:10 | 3769.25 | 0.00 |
| October | 0.00 | 0.00 | 0.675340E+10 | 0.442136E+10 | 5373.73 | 29-OCT-13:30 | 3689.62 | 0.00 |
| November | 0.00 | 0.00 | 0.635919E+10 | 0.442967E+10 | 5030.51 | 04-NOV-15:20 | 3750.24 | 0.00 |
| December | 0.00 | 0.00 | 0.612410E+10 | 0.451624E+10 | 4714.04 | 30-DEC-14:30 | 3713.23 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.837974E+11 | 0.570705E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.610456E+10 | 0.442136E+10 | 4714.04 | 3518.17 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.829475E+10 | 0.529971E+10 | 6075.66 | 4544.65 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.537332E+10 | 0.394716E+10 | 3968.51 | 03-JAN-14:20 | 3142.00 | 0.00 |
| February | 0.00 | 0.00 | 0.544854E+10 | 0.401838E+10 | 4733.23 | 28-FEB-15:20 | 3746.78 | 0.00 |
| March | 0.00 | 0.00 | 0.701075E+10 | 0.502269E+10 | 5430.02 | 19-MAR-16:10 | 4194.02 | 0.00 |
| April | 0.00 | 0.00 | 0.767774E+10 | 0.522785E+10 | 5468.68 | 02-APR-16:10 | 3972.59 | 0.00 |
| May | 0.00 | 0.00 | 0.859329E+10 | 0.549005E+10 | 6294.74 | 06-MAY-15:10 | 4709.13 | 0.00 |
| June | 0.00 | 0.00 | 0.860407E+10 | 0.555587E+10 | 6500.44 | 16-JUN-15:30 | 4466.93 | 0.00 |
| July | 0.00 | 0.00 | 0.686312E+10 | 0.475624E+10 | 5213.81 | 04-JUL-16:10 | 3885.40 | 0.00 |
| August | 0.00 | 0.00 | 0.754982E+10 | 0.467970E+10 | 5629.75 | 01-AUG-15:10 | 3856.99 | 0.00 |
| September | 0.00 | 0.00 | 0.684228E+10 | 0.442661E+10 | 5258.58 | 10-SEP-15:10 | 3652.38 | 0.00 |
| October | 0.00 | 0.00 | 0.641721E+10 | 0.413144E+10 | 4920.93 | 04-OCT-15:20 | 3564.91 | 0.00 |
| November | 0.00 | 0.00 | 0.572450E+10 | 0.387120E+10 | 4406.29 | 10-NOV-13:30 | 2793.39 | 0.00 |
| December | 0.00 | 0.00 | 0.521321E+10 | 0.370631E+10 | 3912.63 | 30-DEC-16:10 | 2856.50 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.813178E+11 | 0.548335E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.521321E+10 | 0.370631E+10 | 3912.63 | 2793.39 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.860407E+10 | 0.555587E+10 | 6500.44 | 4709.13 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.628549E+10 | 0.473972E+10 | 4930.58 | 04-JAN-13:00 | 4149.10 | 0.00 |
| February | 0.00 | 0.00 | 0.613077E+10 | 0.461254E+10 | 4903.95 | 28-FEB-15:00 | 3963.17 | 0.00 |
| March | 0.00 | 0.00 | 0.730680E+10 | 0.526529E+10 | 5285.42 | 19-MAR-16:10 | 4025.28 | 0.00 |
| April | 0.00 | 0.00 | 0.764557E+10 | 0.517810E+10 | 4964.01 | 02-APR-16:10 | 3498.07 | 0.00 |
| May | 0.00 | 0.00 | 0.833605E+10 | 0.524794E+10 | 5535.91 | 06-MAY-15:10 | 4038.97 | 0.00 |
| June | 0.00 | 0.00 | 0.813344E+10 | 0.512855E+10 | 5371.38 | 16-JUN-15:20 | 3526.38 | 0.00 |
| July | 0.00 | 0.00 | 0.660121E+10 | 0.450448E+10 | 4418.05 | 01-JUL-13:00 | 3192.42 | 0.00 |
| August | 0.00 | 0.00 | 0.742534E+10 | 0.455696E+10 | 5162.71 | 12-AUG-12:00 | 3192.64 | 0.00 |
| September | 0.00 | 0.00 | 0.697278E+10 | 0.452149E+10 | 4935.60 | 25-SEP-14:00 | 3193.03 | 0.00 |
| October | 0.00 | 0.00 | 0.677617E+10 | 0.442322E+10 | 5306.42 | 29-OCT-13:00 | 3665.56 | 0.00 |
| November | 0.00 | 0.00 | 0.638392E+10 | 0.443200E+10 | 4793.08 | 18-NOV-13:00 | 3859.73 | 0.00 |
| December | 0.00 | 0.00 | 0.614291E+10 | 0.450961E+10 | 4656.05 | 31-DEC-13:00 | 3706.25 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.841404E+11 | 0.571199E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.613077E+10 | 0.442322E+10 | 4418.05 | 3192.42 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.833605E+10 | 0.526529E+10 | 5535.91 | 4149.10 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.538232E+10 | 0.393276E+10 | 3884.35 | 04-JAN-13:00 | 3149.32 | 0.00 |
| February | 0.00 | 0.00 | 0.547176E+10 | 0.402040E+10 | 4308.71 | 28-FEB-15:00 | 3395.94 | 0.00 |
| March | 0.00 | 0.00 | 0.699337E+10 | 0.498852E+10 | 4874.38 | 19-MAR-16:10 | 3681.82 | 0.00 |
| April | 0.00 | 0.00 | 0.769161E+10 | 0.522424E+10 | 4884.98 | 30-APR-16:10 | 3355.81 | 0.00 |
| May | 0.00 | 0.00 | 0.862919E+10 | 0.550612E+10 | 5777.39 | 06-MAY-15:10 | 4255.52 | 0.00 |
| June | 0.00 | 0.00 | 0.865014E+10 | 0.558037E+10 | 5960.93 | 16-JUN-15:20 | 4018.32 | 0.00 |
| July | 0.00 | 0.00 | 0.689442E+10 | 0.476690E+10 | 4593.12 | 04-JUL-16:10 | 3336.20 | 0.00 |
| August | 0.00 | 0.00 | 0.759856E+10 | 0.470536E+10 | 5263.68 | 07-AUG-12:00 | 3284.35 | 0.00 |
| September | 0.00 | 0.00 | 0.688685E+10 | 0.445179E+10 | 4797.49 | 02-SEP-14:10 | 3291.91 | 0.00 |
| October | 0.00 | 0.00 | 0.643603E+10 | 0.413361E+10 | 4673.09 | 29-OCT-13:00 | 3125.76 | 0.00 |
| November | 0.00 | 0.00 | 0.574617E+10 | 0.387396E+10 | 4377.13 | 10-NOV-13:20 | 2792.84 | 0.00 |
| December | 0.00 | 0.00 | 0.522944E+10 | 0.369994E+10 | 3824.67 | 09-DEC-14:00 | 2706.46 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.816099E+11 | 0.548840E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.522944E+10 | 0.369994E+10 | 3824.67 | 2706.46 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.865014E+10 | 0.558037E+10 | 5960.93 | 4255.52 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.459788E+10 | 0.334252E+10 | 3052.86 | 03-JAN-14:00 | 2420.77 | 0.00 |
| February | 0.00 | 0.00 | 0.459323E+10 | 0.335414E+10 | 3403.05 | 28-FEB-15:10 | 2679.94 | 0.00 |
| March | 0.00 | 0.00 | 0.577867E+10 | 0.411551E+10 | 3840.09 | 19-MAR-16:10 | 2954.23 | 0.00 |
| April | 0.00 | 0.00 | 0.639268E+10 | 0.431826E+10 | 3967.95 | 30-APR-16:10 | 2767.90 | 0.00 |
| May | 0.00 | 0.00 | 0.726803E+10 | 0.463703E+10 | 4607.19 | 06-MAY-15:10 | 3431.51 | 0.00 |
| June | 0.00 | 0.00 | 0.728774E+10 | 0.470224E+10 | 4751.72 | 16-JUN-15:30 | 3285.18 | 0.00 |
| July | 0.00 | 0.00 | 0.592310E+10 | 0.408728E+10 | 3825.18 | 04-JUL-16:10 | 2829.96 | 0.00 |
| August | 0.00 | 0.00 | 0.641286E+10 | 0.397728E+10 | 4225.70 | 01-AUG-15:10 | 2883.28 | 0.00 |
| September | 0.00 | 0.00 | 0.586916E+10 | 0.376689E+10 | 3788.21 | 25-SEP-14:00 | 2433.35 | 0.00 |
| October | 0.00 | 0.00 | 0.555288E+10 | 0.355162E+10 | 3627.98 | 29-OCT-13:00 | 2446.30 | 0.00 |
| November | 0.00 | 0.00 | 0.497267E+10 | 0.333110E+10 | 3449.17 | 10-NOV-13:30 | 2210.06 | 0.00 |
| December | 0.00 | 0.00 | 0.452534E+10 | 0.317799E+10 | 3056.23 | 09-DEC-14:00 | 2182.39 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.691742E+11 | 0.463618E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.452534E+10 | 0.317799E+10 | 3052.86 | 2182.39 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.728774E+10 | 0.470224E+10 | 4751.72 | 3431.51 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.459868E+10 | 0.334278E+10 | 3054.98 | 03-JAN-14:00 | 2423.19 | 0.00 |
| February | 0.00 | 0.00 | 0.459450E+10 | 0.335486E+10 | 3397.98 | 28-FEB-15:10 | 2675.92 | 0.00 |
| March | 0.00 | 0.00 | 0.577825E+10 | 0.411484E+10 | 3826.33 | 19-MAR-16:10 | 2941.99 | 0.00 |
| April | 0.00 | 0.00 | 0.639332E+10 | 0.431853E+10 | 3956.21 | 30-APR-16:10 | 2758.00 | 0.00 |
| May | 0.00 | 0.00 | 0.726933E+10 | 0.463782E+10 | 4599.53 | 06-MAY-15:10 | 3425.20 | 0.00 |
| June | 0.00 | 0.00 | 0.728937E+10 | 0.470333E+10 | 4742.63 | 16-JUN-15:30 | 3277.87 | 0.00 |
| July | 0.00 | 0.00 | 0.592436E+10 | 0.408794E+10 | 3811.52 | 04-JUL-16:10 | 2818.15 | 0.00 |
| August | 0.00 | 0.00 | 0.641469E+10 | 0.397845E+10 | 4221.09 | 01-AUG-15:10 | 2880.21 | 0.00 |
| September | 0.00 | 0.00 | 0.587093E+10 | 0.376807E+10 | 3786.93 | 25-SEP-14:00 | 2433.18 | 0.00 |
| October | 0.00 | 0.00 | 0.555368E+10 | 0.355196E+10 | 3631.41 | 29-OCT-13:00 | 2449.78 | 0.00 |
| November | 0.00 | 0.00 | 0.497361E+10 | 0.333154E+10 | 3452.94 | 10-NOV-13:30 | 2213.77 | 0.00 |
| December | 0.00 | 0.00 | 0.452631E+10 | 0.317842E+10 | 3055.80 | 09-DEC-14:00 | 2182.11 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.691870E+11 | 0.463685E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.452631E+10 | 0.317842E+10 | 3054.98 | 2182.11 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.728937E+10 | 0.470333E+10 | 4742.63 | 3425.20 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.551309E+10 | 0.415930E+10 | 4089.16 | 04-JAN-13:00 | 3454.38 | 0.00 |
| February | 0.00 | 0.00 | 0.526138E+10 | 0.395309E+10 | 3998.64 | 28-FEB-15:00 | 3261.76 | 0.00 |
| March | 0.00 | 0.00 | 0.609457E+10 | 0.439563E+10 | 4251.49 | 19-MAR-16:10 | 3304.09 | 0.00 |
| April | 0.00 | 0.00 | 0.634490E+10 | 0.427198E+10 | 4085.76 | 02-APR-16:10 | 2907.97 | 0.00 |
| May | 0.00 | 0.00 | 0.697006E+10 | 0.437609E+10 | 4363.57 | 06-MAY-15:20 | 3191.68 | 0.00 |
| June | 0.00 | 0.00 | 0.676351E+10 | 0.424563E+10 | 4182.14 | 13-JUN-15:10 | 2910.29 | 0.00 |
| July | 0.00 | 0.00 | 0.562443E+10 | 0.382161E+10 | 3517.45 | 04-JUL-16:10 | 2535.44 | 0.00 |
| August | 0.00 | 0.00 | 0.623682E+10 | 0.382738E+10 | 4071.20 | 12-AUG-12:00 | 2528.63 | 0.00 |
| September | 0.00 | 0.00 | 0.595520E+10 | 0.383738E+10 | 3939.34 | 25-SEP-14:00 | 2570.72 | 0.00 |
| October | 0.00 | 0.00 | 0.589703E+10 | 0.384482E+10 | 4258.06 | 29-OCT-13:00 | 2991.00 | 0.00 |
| November | 0.00 | 0.00 | 0.561950E+10 | 0.389606E+10 | 4108.71 | 18-NOV-13:00 | 3293.17 | 0.00 |
| December | 0.00 | 0.00 | 0.545187E+10 | 0.399786E+10 | 3922.19 | 31-DEC-13:00 | 3112.37 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.717324E+11 | 0.486268E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.526138E+10 | 0.382161E+10 | 3517.45 | 2528.63 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.697006E+10 | 0.439563E+10 | 4363.57 | 3454.38 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.551373E+10 | 0.415940E+10 | 4097.13 | 04-JAN-13:00 | 3462.24 | 0.00 |
| February | 0.00 | 0.00 | 0.526252E+10 | 0.395370E+10 | 3994.55 | 28-FEB-15:00 | 3258.38 | 0.00 |
| March | 0.00 | 0.00 | 0.609416E+10 | 0.439493E+10 | 4237.64 | 19-MAR-16:10 | 3291.58 | 0.00 |
| April | 0.00 | 0.00 | 0.634558E+10 | 0.427225E+10 | 4070.68 | 02-APR-16:10 | 2895.05 | 0.00 |
| May | 0.00 | 0.00 | 0.697144E+10 | 0.437690E+10 | 4354.72 | 06-MAY-15:20 | 3184.40 | 0.00 |
| June | 0.00 | 0.00 | 0.676525E+10 | 0.424676E+10 | 4175.93 | 13-JUN-15:10 | 2905.61 | 0.00 |
| July | 0.00 | 0.00 | 0.562576E+10 | 0.382230E+10 | 3503.63 | 04-JUL-16:10 | 2523.75 | 0.00 |
| August | 0.00 | 0.00 | 0.623870E+10 | 0.382856E+10 | 4075.60 | 12-AUG-12:00 | 2532.33 | 0.00 |
| September | 0.00 | 0.00 | 0.595698E+10 | 0.383854E+10 | 3938.08 | 25-SEP-14:00 | 2570.49 | 0.00 |
| October | 0.00 | 0.00 | 0.589782E+10 | 0.384512E+10 | 4261.26 | 29-OCT-13:00 | 2994.22 | 0.00 |
| November | 0.00 | 0.00 | 0.562034E+10 | 0.389640E+10 | 4112.09 | 18-NOV-13:00 | 3296.85 | 0.00 |
| December | 0.00 | 0.00 | 0.545266E+10 | 0.399813E+10 | 3929.70 | 31-DEC-13:00 | 3119.83 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.717449E+11 | 0.486330E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.526252E+10 | 0.382230E+10 | 3503.63 | 2523.75 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.697144E+10 | 0.439493E+10 | 4354.72 | 3462.24 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.357291E+09 | 1.01 | 219.05 | 05-JAN-15:00 | 0.98 |
| February | 0.342047E+09 | 1.01 | 231.78 | 28-FEB-15:10 | 0.97 |
| March | 0.391619E+09 | 1.01 | 248.81 | 19-MAR-16:10 | 0.96 |
| April | 0.400713E+09 | 1.00 | 242.97 | 02-APR-16:10 | 0.96 |
| May | 0.435279E+09 | 1.00 | 260.48 | 06-MAY-15:10 | 0.96 |
| June | 0.425658E+09 | 1.00 | 251.34 | 13-JUN-16:01 | 0.96 |
| July | 0.368549E+09 | 1.01 | 213.98 | 04-JUL-16:10 | 0.98 |
| August | 0.399470E+09 | 1.00 | 234.96 | 12-AUG-16:40 | 0.97 |
| September | 0.380448E+09 | 1.00 | 230.50 | 04-SEP-16:03 | 0.97 |
| October | 0.372962E+09 | 1.01 | 227.12 | 29-OCT-13:00 | 0.97 |
| November | 0.358649E+09 | 1.01 | 219.66 | 04-NOV-15:20 | 0.98 |
| December | 0.354628E+09 | 1.01 | 208.98 | 30-DEC-14:20 | 0.98 |
| Annual Sum or Average | 0.458731E+10 | 1.00 | |||
| Minimum of Months | 0.342047E+09 | 1.00 | 208.98 | 0.96 | |
| Maximum of Months | 0.435279E+09 | 1.01 | 260.48 | 0.98 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.311606E+09 | 1.02 | 181.91 | 05-JAN-15:00 | 0.99 |
| February | 0.308732E+09 | 1.01 | 208.42 | 28-FEB-15:10 | 0.98 |
| March | 0.377254E+09 | 1.01 | 233.07 | 19-MAR-16:10 | 0.97 |
| April | 0.406124E+09 | 1.00 | 236.90 | 02-APR-16:10 | 0.97 |
| May | 0.453807E+09 | 0.99 | 272.87 | 06-MAY-15:10 | 0.95 |
| June | 0.455808E+09 | 0.99 | 276.05 | 13-JUN-16:01 | 0.95 |
| July | 0.387296E+09 | 1.01 | 227.13 | 04-JUL-16:10 | 0.97 |
| August | 0.411600E+09 | 1.00 | 241.62 | 09-AUG-16:10 | 0.96 |
| September | 0.379178E+09 | 1.00 | 227.37 | 04-SEP-16:03 | 0.97 |
| October | 0.357773E+09 | 1.01 | 213.07 | 04-OCT-16:03 | 0.98 |
| November | 0.327328E+09 | 1.01 | 193.79 | 04-NOV-15:10 | 0.99 |
| December | 0.308513E+09 | 1.02 | 178.91 | 30-DEC-16:10 | 0.99 |
| Annual Sum or Average | 0.448502E+10 | 1.01 | |||
| Minimum of Months | 0.308513E+09 | 0.99 | 178.91 | 0.95 | |
| Maximum of Months | 0.455808E+09 | 1.02 | 276.05 | 0.99 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.116268E+10 | 0.90 | 434.09 | 01-JAN-00:10 | 0.90 |
| February | 0.105016E+10 | 0.90 | 434.09 | 01-FEB-00:10 | 0.90 |
| March | 0.116268E+10 | 0.90 | 434.09 | 01-MAR-00:10 | 0.90 |
| April | 0.112517E+10 | 0.90 | 434.09 | 01-APR-00:10 | 0.90 |
| May | 0.116268E+10 | 0.90 | 434.09 | 01-MAY-00:10 | 0.90 |
| June | 0.112517E+10 | 0.90 | 434.09 | 01-JUN-00:10 | 0.90 |
| July | 0.116268E+10 | 0.90 | 434.09 | 01-JUL-00:10 | 0.90 |
| August | 0.116268E+10 | 0.90 | 434.09 | 01-AUG-00:10 | 0.90 |
| September | 0.112517E+10 | 0.90 | 434.09 | 01-SEP-00:10 | 0.89 |
| October | 0.116268E+10 | 0.90 | 434.09 | 01-OCT-00:10 | 0.89 |
| November | 0.112517E+10 | 0.90 | 434.09 | 01-NOV-00:10 | 0.90 |
| December | 0.116268E+10 | 0.90 | 434.09 | 01-DEC-00:10 | 0.90 |
| Annual Sum or Average | 0.136896E+11 | 0.90 | |||
| Minimum of Months | 0.105016E+10 | 0.90 | 434.09 | 0.89 | |
| Maximum of Months | 0.116268E+10 | 0.90 | 434.09 | 0.90 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.307788E+09 | 1.02 | 177.53 | 04-JAN-13:00 | 0.99 |
| February | 0.305502E+09 | 1.01 | 194.07 | 28-FEB-15:00 | 0.98 |
| March | 0.371477E+09 | 1.01 | 213.82 | 19-MAR-16:10 | 0.97 |
| April | 0.401243E+09 | 1.00 | 216.29 | 30-APR-16:20 | 0.97 |
| May | 0.448909E+09 | 0.99 | 254.86 | 06-MAY-15:10 | 0.96 |
| June | 0.450956E+09 | 0.99 | 257.45 | 13-JUN-15:10 | 0.95 |
| July | 0.383069E+09 | 1.00 | 206.43 | 28-JUL-13:00 | 0.98 |
| August | 0.407680E+09 | 1.00 | 227.14 | 01-AUG-15:10 | 0.97 |
| September | 0.375877E+09 | 1.00 | 211.63 | 02-SEP-14:10 | 0.97 |
| October | 0.353524E+09 | 1.01 | 198.56 | 29-OCT-13:00 | 0.98 |
| November | 0.323861E+09 | 1.01 | 189.71 | 10-NOV-13:30 | 0.98 |
| December | 0.304903E+09 | 1.02 | 174.33 | 09-DEC-14:00 | 0.99 |
| Annual Sum or Average | 0.443479E+10 | 1.00 | |||
| Minimum of Months | 0.304903E+09 | 0.99 | 174.33 | 0.95 | |
| Maximum of Months | 0.450956E+09 | 1.02 | 257.45 | 0.99 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.266109E+09 | 1.02 | 142.79 | 04-JAN-13:00 | 1.00 |
| February | 0.260382E+09 | 1.01 | 155.76 | 28-FEB-15:00 | 0.99 |
| March | 0.312594E+09 | 1.01 | 172.25 | 19-MAR-16:10 | 0.98 |
| April | 0.339082E+09 | 1.00 | 179.31 | 30-APR-16:20 | 0.98 |
| May | 0.385181E+09 | 0.99 | 206.78 | 06-MAY-15:10 | 0.97 |
| June | 0.386260E+09 | 0.99 | 215.88 | 13-JUN-16:01 | 0.96 |
| July | 0.331694E+09 | 1.01 | 173.96 | 26-JUL-17:00 | 0.98 |
| August | 0.349436E+09 | 1.00 | 187.32 | 13-AUG-15:10 | 0.97 |
| September | 0.322995E+09 | 1.00 | 174.31 | 04-SEP-16:03 | 0.98 |
| October | 0.308664E+09 | 1.01 | 159.25 | 29-OCT-13:00 | 0.99 |
| November | 0.282739E+09 | 1.01 | 154.42 | 10-NOV-13:40 | 0.99 |
| December | 0.265860E+09 | 1.02 | 143.50 | 09-DEC-14:00 | 1.00 |
| Annual Sum or Average | 0.381100E+10 | 1.01 | |||
| Minimum of Months | 0.260382E+09 | 0.99 | 142.79 | 0.96 | |
| Maximum of Months | 0.386260E+09 | 1.02 | 215.88 | 1.00 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.266044E+09 | 1.02 | 142.97 | 04-JAN-13:00 | 1.00 |
| February | 0.260331E+09 | 1.01 | 155.66 | 28-FEB-15:00 | 0.99 |
| March | 0.312464E+09 | 1.01 | 171.93 | 19-MAR-16:10 | 0.98 |
| April | 0.338990E+09 | 1.00 | 179.02 | 30-APR-16:20 | 0.98 |
| May | 0.385098E+09 | 0.99 | 206.61 | 06-MAY-15:10 | 0.97 |
| June | 0.386181E+09 | 0.99 | 215.56 | 13-JUN-16:10 | 0.96 |
| July | 0.331624E+09 | 1.01 | 173.75 | 26-JUL-17:00 | 0.98 |
| August | 0.349384E+09 | 1.00 | 187.09 | 13-AUG-15:10 | 0.97 |
| September | 0.322964E+09 | 1.00 | 174.10 | 04-SEP-16:03 | 0.98 |
| October | 0.308576E+09 | 1.01 | 159.24 | 29-OCT-13:00 | 0.99 |
| November | 0.282683E+09 | 1.01 | 154.53 | 10-NOV-13:40 | 0.99 |
| December | 0.265792E+09 | 1.02 | 143.45 | 09-DEC-14:00 | 1.00 |
| Annual Sum or Average | 0.381013E+10 | 1.01 | |||
| Minimum of Months | 0.260331E+09 | 0.99 | 142.97 | 0.96 | |
| Maximum of Months | 0.386181E+09 | 1.02 | 215.56 | 1.00 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.312850E+09 | 1.01 | 181.53 | 04-JAN-13:00 | 0.98 |
| February | 0.294642E+09 | 1.01 | 179.89 | 28-FEB-15:00 | 0.98 |
| March | 0.327711E+09 | 1.01 | 188.23 | 19-MAR-16:10 | 0.98 |
| April | 0.334008E+09 | 1.00 | 182.51 | 02-APR-16:10 | 0.98 |
| May | 0.366682E+09 | 1.00 | 194.38 | 06-MAY-15:10 | 0.97 |
| June | 0.355859E+09 | 1.00 | 191.32 | 11-JUN-16:02 | 0.97 |
| July | 0.313035E+09 | 1.01 | 163.46 | 15-JUL-16:15 | 0.99 |
| August | 0.337429E+09 | 1.00 | 181.20 | 12-AUG-17:00 | 0.98 |
| September | 0.324612E+09 | 1.00 | 177.56 | 04-SEP-16:03 | 0.98 |
| October | 0.324459E+09 | 1.01 | 183.88 | 29-OCT-13:00 | 0.98 |
| November | 0.314877E+09 | 1.01 | 184.52 | 18-NOV-13:00 | 0.98 |
| December | 0.312957E+09 | 1.01 | 176.80 | 31-DEC-13:00 | 0.98 |
| Annual Sum or Average | 0.391912E+10 | 1.01 | |||
| Minimum of Months | 0.294642E+09 | 1.00 | 163.46 | 0.97 | |
| Maximum of Months | 0.366682E+09 | 1.01 | 194.38 | 0.99 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.336152E+09 | 1.01 | 188.84 | 04-JAN-13:00 | 0.98 |
| February | 0.315393E+09 | 1.00 | 186.55 | 28-FEB-15:00 | 0.98 |
| March | 0.350028E+09 | 1.00 | 199.29 | 19-MAR-16:10 | 0.97 |
| April | 0.357049E+09 | 1.00 | 193.57 | 02-APR-16:10 | 0.97 |
| May | 0.390628E+09 | 0.99 | 204.73 | 06-MAY-15:10 | 0.97 |
| June | 0.378775E+09 | 0.99 | 202.59 | 11-JUN-16:02 | 0.97 |
| July | 0.336461E+09 | 1.01 | 172.96 | 15-JUL-16:15 | 0.98 |
| August | 0.359966E+09 | 1.00 | 192.39 | 13-AUG-15:10 | 0.97 |
| September | 0.347167E+09 | 1.00 | 189.22 | 04-SEP-16:03 | 0.97 |
| October | 0.347543E+09 | 1.00 | 194.82 | 29-OCT-13:00 | 0.97 |
| November | 0.337058E+09 | 1.00 | 193.60 | 18-NOV-13:00 | 0.97 |
| December | 0.334903E+09 | 1.01 | 187.71 | 31-DEC-13:00 | 0.98 |
| Annual Sum or Average | 0.419112E+10 | 1.00 | |||
| Minimum of Months | 0.315393E+09 | 0.99 | 172.96 | 0.97 | |
| Maximum of Months | 0.390628E+09 | 1.01 | 204.73 | 0.98 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.722476E+09 | 1.02 | 479.26 | 05-JAN-15:00 | 0.98 |
| February | 0.693250E+09 | 1.01 | 510.07 | 28-FEB-15:10 | 0.97 |
| March | 0.805241E+09 | 1.01 | 552.63 | 19-MAR-16:10 | 0.96 |
| April | 0.820475E+09 | 1.01 | 532.11 | 02-APR-16:10 | 0.97 |
| May | 0.884932E+09 | 1.00 | 572.05 | 06-MAY-15:10 | 0.96 |
| June | 0.857514E+09 | 1.00 | 539.60 | 16-JUN-15:30 | 0.96 |
| July | 0.724454E+09 | 1.01 | 463.05 | 04-JUL-16:10 | 0.98 |
| August | 0.797042E+09 | 1.01 | 503.34 | 12-AUG-16:15 | 0.97 |
| September | 0.753813E+09 | 1.01 | 493.51 | 04-SEP-16:03 | 0.97 |
| October | 0.751660E+09 | 1.01 | 500.03 | 29-OCT-13:00 | 0.97 |
| November | 0.719636E+09 | 1.01 | 479.63 | 04-NOV-15:20 | 0.98 |
| December | 0.709524E+09 | 1.02 | 452.67 | 07-DEC-14:20 | 0.98 |
| Annual Sum or Average | 0.924002E+10 | 1.01 | |||
| Minimum of Months | 0.693250E+09 | 1.00 | 452.67 | 0.96 | |
| Maximum of Months | 0.884932E+09 | 1.02 | 572.05 | 0.98 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.622057E+09 | 1.02 | 390.18 | 05-JAN-15:00 | 1.00 |
| February | 0.620491E+09 | 1.02 | 454.99 | 28-FEB-15:10 | 0.98 |
| March | 0.772845E+09 | 1.01 | 515.63 | 19-MAR-16:10 | 0.97 |
| April | 0.829070E+09 | 1.01 | 516.49 | 02-APR-16:10 | 0.97 |
| May | 0.921328E+09 | 1.00 | 597.17 | 06-MAY-15:10 | 0.95 |
| June | 0.918682E+09 | 1.00 | 596.71 | 16-JUN-15:30 | 0.95 |
| July | 0.761067E+09 | 1.01 | 493.01 | 04-JUL-16:10 | 0.97 |
| August | 0.819792E+09 | 1.01 | 521.25 | 01-AUG-15:10 | 0.97 |
| September | 0.747911E+09 | 1.01 | 484.46 | 04-SEP-16:03 | 0.98 |
| October | 0.716439E+09 | 1.01 | 464.54 | 04-OCT-16:03 | 0.98 |
| November | 0.650062E+09 | 1.02 | 416.09 | 04-NOV-15:10 | 0.99 |
| December | 0.608145E+09 | 1.02 | 380.22 | 30-DEC-16:10 | 1.00 |
| Annual Sum or Average | 0.898789E+10 | 1.01 | |||
| Minimum of Months | 0.608145E+09 | 1.00 | 380.22 | 0.95 | |
| Maximum of Months | 0.921328E+09 | 1.02 | 597.17 | 1.00 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.712266E+09 | 1.01 | 471.82 | 04-JAN-13:00 | 0.98 |
| February | 0.684903E+09 | 1.01 | 471.06 | 28-FEB-15:00 | 0.97 |
| March | 0.791533E+09 | 1.01 | 502.74 | 19-MAR-16:10 | 0.97 |
| April | 0.809481E+09 | 1.00 | 467.90 | 02-APR-16:10 | 0.97 |
| May | 0.874450E+09 | 1.00 | 522.51 | 06-MAY-15:10 | 0.96 |
| June | 0.847953E+09 | 1.00 | 496.39 | 11-JUN-10:00 | 0.97 |
| July | 0.716132E+09 | 1.01 | 413.16 | 01-JUL-13:00 | 0.98 |
| August | 0.788943E+09 | 1.01 | 468.67 | 12-AUG-12:00 | 0.97 |
| September | 0.746489E+09 | 1.01 | 452.65 | 02-SEP-14:00 | 0.98 |
| October | 0.741721E+09 | 1.01 | 488.93 | 29-OCT-13:00 | 0.97 |
| November | 0.710613E+09 | 1.01 | 459.81 | 18-NOV-13:00 | 0.98 |
| December | 0.700001E+09 | 1.01 | 442.69 | 31-DEC-13:00 | 0.98 |
| Annual Sum or Average | 0.912448E+10 | 1.01 | |||
| Minimum of Months | 0.684903E+09 | 1.00 | 413.16 | 0.96 | |
| Maximum of Months | 0.874450E+09 | 1.01 | 522.51 | 0.98 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.613578E+09 | 1.02 | 376.74 | 04-JAN-13:00 | 0.99 |
| February | 0.613466E+09 | 1.02 | 415.64 | 28-FEB-15:00 | 0.99 |
| March | 0.759628E+09 | 1.01 | 466.13 | 19-MAR-16:10 | 0.98 |
| April | 0.817928E+09 | 1.00 | 460.77 | 30-APR-16:10 | 0.97 |
| May | 0.910239E+09 | 1.00 | 547.17 | 06-MAY-15:10 | 0.96 |
| June | 0.908044E+09 | 1.00 | 545.11 | 13-JUN-15:10 | 0.96 |
| July | 0.752064E+09 | 1.01 | 432.69 | 28-JUL-13:00 | 0.98 |
| August | 0.811355E+09 | 1.00 | 483.30 | 01-AUG-15:10 | 0.97 |
| September | 0.740763E+09 | 1.01 | 447.84 | 02-SEP-14:00 | 0.98 |
| October | 0.707182E+09 | 1.01 | 431.06 | 29-OCT-13:00 | 0.98 |
| November | 0.642334E+09 | 1.02 | 406.07 | 10-NOV-13:30 | 0.98 |
| December | 0.600419E+09 | 1.02 | 368.89 | 09-DEC-14:00 | 0.99 |
| Annual Sum or Average | 0.887700E+10 | 1.01 | |||
| Minimum of Months | 0.600419E+09 | 1.00 | 368.89 | 0.96 | |
| Maximum of Months | 0.910239E+09 | 1.02 | 547.17 | 0.99 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.527246E+09 | 1.02 | 295.48 | 04-JAN-13:00 | 1.00 |
| February | 0.517701E+09 | 1.02 | 325.68 | 28-FEB-15:00 | 1.00 |
| March | 0.629837E+09 | 1.01 | 366.44 | 19-MAR-16:10 | 0.99 |
| April | 0.681352E+09 | 1.01 | 374.58 | 30-APR-16:15 | 0.98 |
| May | 0.772149E+09 | 1.00 | 434.72 | 06-MAY-15:10 | 0.97 |
| June | 0.770233E+09 | 1.00 | 448.62 | 13-JUN-16:03 | 0.97 |
| July | 0.650010E+09 | 1.01 | 361.84 | 04-JUL-16:10 | 0.99 |
| August | 0.691347E+09 | 1.01 | 390.38 | 01-AUG-15:10 | 0.98 |
| September | 0.634200E+09 | 1.01 | 356.17 | 04-SEP-16:03 | 0.99 |
| October | 0.613907E+09 | 1.01 | 337.31 | 29-OCT-13:00 | 0.99 |
| November | 0.558837E+09 | 1.02 | 323.42 | 10-NOV-13:30 | 0.99 |
| December | 0.522825E+09 | 1.02 | 297.97 | 09-DEC-14:00 | 1.00 |
| Annual Sum or Average | 0.756964E+10 | 1.01 | |||
| Minimum of Months | 0.517701E+09 | 1.00 | 295.48 | 0.97 | |
| Maximum of Months | 0.772149E+09 | 1.02 | 448.62 | 1.00 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.527104E+09 | 1.02 | 295.95 | 04-JAN-13:00 | 1.00 |
| February | 0.517601E+09 | 1.02 | 325.48 | 28-FEB-15:00 | 1.00 |
| March | 0.629563E+09 | 1.01 | 365.67 | 19-MAR-16:10 | 0.99 |
| April | 0.681155E+09 | 1.01 | 373.88 | 30-APR-16:15 | 0.98 |
| May | 0.771964E+09 | 1.00 | 434.30 | 06-MAY-15:10 | 0.97 |
| June | 0.770061E+09 | 1.00 | 447.88 | 13-JUN-16:03 | 0.97 |
| July | 0.649861E+09 | 1.01 | 360.93 | 04-JUL-16:10 | 0.99 |
| August | 0.691233E+09 | 1.01 | 390.16 | 01-AUG-15:10 | 0.98 |
| September | 0.634122E+09 | 1.01 | 355.61 | 04-SEP-16:03 | 0.99 |
| October | 0.613727E+09 | 1.01 | 337.35 | 29-OCT-13:00 | 0.99 |
| November | 0.558709E+09 | 1.02 | 323.70 | 10-NOV-13:30 | 0.99 |
| December | 0.522688E+09 | 1.02 | 297.87 | 09-DEC-14:00 | 1.00 |
| Annual Sum or Average | 0.756779E+10 | 1.01 | |||
| Minimum of Months | 0.517601E+09 | 1.00 | 295.95 | 0.97 | |
| Maximum of Months | 0.771964E+09 | 1.02 | 447.88 | 1.00 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.626913E+09 | 1.02 | 390.82 | 04-JAN-13:00 | 0.98 |
| February | 0.589930E+09 | 1.01 | 381.50 | 28-FEB-15:00 | 0.98 |
| March | 0.661392E+09 | 1.01 | 403.04 | 19-MAR-16:10 | 0.98 |
| April | 0.671347E+09 | 1.01 | 382.43 | 02-APR-16:10 | 0.98 |
| May | 0.733826E+09 | 1.00 | 408.65 | 06-MAY-15:10 | 0.98 |
| June | 0.706844E+09 | 1.00 | 393.49 | 11-JUN-16:02 | 0.98 |
| July | 0.611698E+09 | 1.01 | 332.05 | 15-JUL-16:02 | 0.99 |
| August | 0.666939E+09 | 1.01 | 373.73 | 12-AUG-12:00 | 0.98 |
| September | 0.638755E+09 | 1.01 | 365.46 | 24-SEP-16:03 | 0.98 |
| October | 0.648002E+09 | 1.01 | 395.53 | 29-OCT-13:00 | 0.98 |
| November | 0.627511E+09 | 1.01 | 392.70 | 18-NOV-13:00 | 0.98 |
| December | 0.623350E+09 | 1.02 | 373.54 | 31-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.780651E+10 | 1.01 | |||
| Minimum of Months | 0.589930E+09 | 1.00 | 332.05 | 0.98 | |
| Maximum of Months | 0.733826E+09 | 1.02 | 408.65 | 0.99 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.626699E+09 | 1.02 | 391.20 | 04-JAN-13:00 | 0.98 |
| February | 0.589767E+09 | 1.01 | 381.25 | 28-FEB-15:00 | 0.98 |
| March | 0.661082E+09 | 1.01 | 402.25 | 19-MAR-16:10 | 0.98 |
| April | 0.671133E+09 | 1.01 | 381.51 | 02-APR-16:10 | 0.98 |
| May | 0.733639E+09 | 1.00 | 408.23 | 06-MAY-15:10 | 0.98 |
| June | 0.706685E+09 | 1.00 | 392.75 | 11-JUN-16:02 | 0.98 |
| July | 0.611550E+09 | 1.01 | 331.65 | 15-JUL-16:02 | 0.99 |
| August | 0.666818E+09 | 1.01 | 373.79 | 12-AUG-12:00 | 0.98 |
| September | 0.638654E+09 | 1.01 | 364.94 | 24-SEP-16:03 | 0.98 |
| October | 0.647785E+09 | 1.01 | 395.53 | 29-OCT-13:00 | 0.98 |
| November | 0.627324E+09 | 1.01 | 392.77 | 18-NOV-13:00 | 0.98 |
| December | 0.623140E+09 | 1.02 | 373.83 | 31-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.780428E+10 | 1.01 | |||
| Minimum of Months | 0.589767E+09 | 1.00 | 331.65 | 0.98 | |
| Maximum of Months | 0.733639E+09 | 1.02 | 408.23 | 0.99 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.61 | 40.01 | 01-MAY-00:10 | 0.61 |
| June | 0.103716E+09 | 0.61 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.61 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.61 | 40.01 | 01-SEP-00:10 | 0.61 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.61 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.62 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.62 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.62 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.62 | 40.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.62 | 40.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.390628E+09 | 1.01 | 310.26 | 05-JAN-15:00 | 0.96 |
| February | 0.380091E+09 | 1.01 | 331.14 | 28-FEB-15:10 | 0.95 |
| March | 0.452581E+09 | 1.01 | 357.99 | 19-MAR-15:50 | 0.95 |
| April | 0.466270E+09 | 1.00 | 339.97 | 02-APR-16:10 | 0.95 |
| May | 0.499824E+09 | 1.00 | 370.41 | 06-MAY-15:20 | 0.94 |
| June | 0.486289E+09 | 1.00 | 346.63 | 16-JUN-15:30 | 0.95 |
| July | 0.402511E+09 | 1.01 | 295.65 | 04-JUL-16:10 | 0.97 |
| August | 0.441960E+09 | 1.01 | 319.62 | 12-AUG-15:20 | 0.95 |
| September | 0.419232E+09 | 1.01 | 319.64 | 10-SEP-15:10 | 0.96 |
| October | 0.409349E+09 | 1.01 | 317.78 | 29-OCT-13:20 | 0.96 |
| November | 0.389643E+09 | 1.01 | 302.41 | 18-NOV-13:00 | 0.96 |
| December | 0.379130E+09 | 1.01 | 294.67 | 07-DEC-14:20 | 0.97 |
| Annual Sum or Average | 0.511751E+10 | 1.01 | |||
| Minimum of Months | 0.379130E+09 | 1.00 | 294.67 | 0.94 | |
| Maximum of Months | 0.499824E+09 | 1.01 | 370.41 | 0.97 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.337279E+09 | 1.02 | 255.74 | 05-JAN-15:00 | 0.98 |
| February | 0.341776E+09 | 1.02 | 298.03 | 28-FEB-15:10 | 0.97 |
| March | 0.435931E+09 | 1.01 | 335.05 | 19-MAR-16:10 | 0.95 |
| April | 0.471460E+09 | 1.00 | 331.83 | 11-APR-16:10 | 0.95 |
| May | 0.519777E+09 | 1.00 | 385.99 | 06-MAY-15:10 | 0.94 |
| June | 0.519292E+09 | 1.00 | 380.79 | 16-JUN-15:30 | 0.94 |
| July | 0.422336E+09 | 1.01 | 315.00 | 04-JUL-16:10 | 0.96 |
| August | 0.454448E+09 | 1.01 | 335.88 | 01-AUG-15:10 | 0.95 |
| September | 0.416282E+09 | 1.01 | 314.84 | 10-SEP-15:00 | 0.96 |
| October | 0.391066E+09 | 1.01 | 299.03 | 04-OCT-15:20 | 0.96 |
| November | 0.352955E+09 | 1.02 | 264.38 | 04-NOV-15:10 | 0.98 |
| December | 0.325180E+09 | 1.02 | 240.04 | 30-DEC-16:10 | 0.99 |
| Annual Sum or Average | 0.498778E+10 | 1.01 | |||
| Minimum of Months | 0.325180E+09 | 1.00 | 240.04 | 0.94 | |
| Maximum of Months | 0.519777E+09 | 1.02 | 385.99 | 0.99 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.383766E+09 | 1.01 | 304.04 | 04-JAN-13:00 | 0.96 |
| February | 0.374291E+09 | 1.01 | 301.87 | 28-FEB-15:00 | 0.96 |
| March | 0.443111E+09 | 1.00 | 317.53 | 19-MAR-16:10 | 0.95 |
| April | 0.458282E+09 | 1.00 | 294.47 | 01-APR-16:10 | 0.96 |
| May | 0.492122E+09 | 1.00 | 333.64 | 06-MAY-15:10 | 0.94 |
| June | 0.479436E+09 | 0.99 | 314.98 | 16-JUN-13:20 | 0.95 |
| July | 0.396803E+09 | 1.01 | 264.72 | 01-JUL-13:00 | 0.97 |
| August | 0.436216E+09 | 1.00 | 297.25 | 12-AUG-12:00 | 0.95 |
| September | 0.413831E+09 | 1.00 | 287.32 | 02-SEP-14:00 | 0.96 |
| October | 0.402684E+09 | 1.01 | 308.67 | 29-OCT-13:00 | 0.95 |
| November | 0.383471E+09 | 1.01 | 294.15 | 18-NOV-13:00 | 0.96 |
| December | 0.372867E+09 | 1.01 | 281.61 | 31-DEC-13:00 | 0.96 |
| Annual Sum or Average | 0.503688E+10 | 1.01 | |||
| Minimum of Months | 0.372867E+09 | 0.99 | 264.72 | 0.94 | |
| Maximum of Months | 0.492122E+09 | 1.01 | 333.64 | 0.97 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.331658E+09 | 1.02 | 244.22 | 04-JAN-13:00 | 0.98 |
| February | 0.336926E+09 | 1.02 | 268.54 | 28-FEB-15:00 | 0.97 |
| March | 0.426824E+09 | 1.01 | 296.39 | 19-MAR-16:10 | 0.96 |
| April | 0.463360E+09 | 1.00 | 287.92 | 30-APR-16:10 | 0.96 |
| May | 0.511619E+09 | 0.99 | 348.92 | 06-MAY-15:10 | 0.94 |
| June | 0.511645E+09 | 0.99 | 344.30 | 16-JUN-13:20 | 0.94 |
| July | 0.416146E+09 | 1.01 | 275.73 | 01-JUL-13:00 | 0.97 |
| August | 0.448447E+09 | 1.00 | 307.41 | 01-AUG-15:10 | 0.95 |
| September | 0.410998E+09 | 1.01 | 284.70 | 02-SEP-14:00 | 0.96 |
| October | 0.384880E+09 | 1.01 | 275.23 | 29-OCT-13:00 | 0.96 |
| November | 0.347701E+09 | 1.02 | 256.22 | 10-NOV-13:20 | 0.97 |
| December | 0.320196E+09 | 1.02 | 230.24 | 09-DEC-14:00 | 0.98 |
| Annual Sum or Average | 0.491040E+10 | 1.01 | |||
| Minimum of Months | 0.320196E+09 | 0.99 | 230.24 | 0.94 | |
| Maximum of Months | 0.511645E+09 | 1.02 | 348.92 | 0.98 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.289220E+09 | 1.02 | 196.64 | 04-JAN-13:00 | 0.99 |
| February | 0.288994E+09 | 1.02 | 218.34 | 28-FEB-15:00 | 0.98 |
| March | 0.361186E+09 | 1.01 | 241.62 | 19-MAR-16:10 | 0.97 |
| April | 0.394212E+09 | 1.00 | 241.26 | 11-APR-16:10 | 0.97 |
| May | 0.441534E+09 | 1.00 | 287.85 | 06-MAY-15:10 | 0.95 |
| June | 0.441826E+09 | 1.00 | 290.28 | 13-JUN-15:10 | 0.95 |
| July | 0.365511E+09 | 1.01 | 234.55 | 04-JUL-16:10 | 0.97 |
| August | 0.387829E+09 | 1.01 | 255.74 | 01-AUG-15:10 | 0.96 |
| September | 0.358002E+09 | 1.01 | 229.99 | 02-SEP-14:10 | 0.97 |
| October | 0.339228E+09 | 1.01 | 220.75 | 29-OCT-13:00 | 0.98 |
| November | 0.307057E+09 | 1.02 | 208.11 | 10-NOV-13:30 | 0.98 |
| December | 0.282637E+09 | 1.02 | 189.28 | 09-DEC-14:00 | 0.99 |
| Annual Sum or Average | 0.425724E+10 | 1.01 | |||
| Minimum of Months | 0.282637E+09 | 1.00 | 189.28 | 0.95 | |
| Maximum of Months | 0.441826E+09 | 1.02 | 290.28 | 0.99 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.289043E+09 | 1.02 | 197.00 | 04-JAN-13:00 | 0.99 |
| February | 0.288844E+09 | 1.02 | 217.92 | 28-FEB-15:00 | 0.98 |
| March | 0.360873E+09 | 1.01 | 240.59 | 19-MAR-16:10 | 0.97 |
| April | 0.393929E+09 | 1.00 | 240.22 | 30-APR-16:10 | 0.97 |
| May | 0.441239E+09 | 1.00 | 287.15 | 06-MAY-15:10 | 0.95 |
| June | 0.441546E+09 | 1.00 | 289.66 | 13-JUN-15:10 | 0.95 |
| July | 0.365286E+09 | 1.01 | 233.56 | 04-JUL-16:10 | 0.97 |
| August | 0.387615E+09 | 1.01 | 255.26 | 01-AUG-15:10 | 0.96 |
| September | 0.357815E+09 | 1.01 | 230.03 | 02-SEP-14:10 | 0.97 |
| October | 0.339002E+09 | 1.01 | 220.77 | 29-OCT-13:00 | 0.98 |
| November | 0.306869E+09 | 1.02 | 208.17 | 10-NOV-13:30 | 0.98 |
| December | 0.282474E+09 | 1.02 | 189.10 | 09-DEC-14:00 | 0.99 |
| Annual Sum or Average | 0.425453E+10 | 1.01 | |||
| Minimum of Months | 0.282474E+09 | 1.00 | 189.10 | 0.95 | |
| Maximum of Months | 0.441546E+09 | 1.02 | 289.66 | 0.99 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.343397E+09 | 1.01 | 258.73 | 04-JAN-13:00 | 0.97 |
| February | 0.328007E+09 | 1.01 | 253.25 | 28-FEB-15:00 | 0.97 |
| March | 0.378225E+09 | 1.01 | 263.89 | 19-MAR-16:10 | 0.96 |
| April | 0.388914E+09 | 1.00 | 248.86 | 02-APR-16:10 | 0.97 |
| May | 0.421114E+09 | 1.00 | 271.77 | 06-MAY-15:10 | 0.96 |
| June | 0.408098E+09 | 1.00 | 257.43 | 13-JUN-15:10 | 0.96 |
| July | 0.345244E+09 | 1.01 | 214.86 | 04-JUL-16:10 | 0.98 |
| August | 0.375035E+09 | 1.01 | 242.63 | 13-AUG-15:10 | 0.97 |
| September | 0.360914E+09 | 1.01 | 238.48 | 30-SEP-14:00 | 0.97 |
| October | 0.357730E+09 | 1.01 | 255.69 | 29-OCT-13:00 | 0.96 |
| November | 0.344250E+09 | 1.01 | 257.40 | 18-NOV-13:00 | 0.96 |
| December | 0.337364E+09 | 1.01 | 242.64 | 31-DEC-13:20 | 0.97 |
| Annual Sum or Average | 0.438829E+10 | 1.01 | |||
| Minimum of Months | 0.328007E+09 | 1.00 | 214.86 | 0.96 | |
| Maximum of Months | 0.421114E+09 | 1.01 | 271.77 | 0.98 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.343137E+09 | 1.01 | 258.96 | 04-JAN-13:00 | 0.96 |
| February | 0.327790E+09 | 1.01 | 252.78 | 28-FEB-15:00 | 0.97 |
| March | 0.377875E+09 | 1.01 | 262.84 | 19-MAR-16:10 | 0.96 |
| April | 0.388619E+09 | 1.00 | 247.76 | 02-APR-16:10 | 0.97 |
| May | 0.420824E+09 | 1.00 | 271.08 | 06-MAY-15:10 | 0.96 |
| June | 0.407840E+09 | 1.00 | 256.84 | 13-JUN-15:10 | 0.96 |
| July | 0.345028E+09 | 1.01 | 213.86 | 04-JUL-16:10 | 0.98 |
| August | 0.374818E+09 | 1.01 | 242.06 | 13-AUG-15:10 | 0.97 |
| September | 0.360706E+09 | 1.01 | 238.03 | 30-SEP-14:00 | 0.97 |
| October | 0.357466E+09 | 1.01 | 255.63 | 29-OCT-13:00 | 0.96 |
| November | 0.344000E+09 | 1.01 | 257.36 | 18-NOV-13:00 | 0.96 |
| December | 0.337117E+09 | 1.01 | 242.83 | 31-DEC-13:00 | 0.97 |
| Annual Sum or Average | 0.438522E+10 | 1.01 | |||
| Minimum of Months | 0.327790E+09 | 1.00 | 213.86 | 0.96 | |
| Maximum of Months | 0.420824E+09 | 1.01 | 271.08 | 0.98 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.61 | 20.01 | 01-MAY-00:10 | 0.61 |
| June | 51857908.47 | 0.61 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.61 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.61 | 20.01 | 01-SEP-00:10 | 0.61 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.61 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.62 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.62 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.62 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.62 | 20.01 | 01-DEC-00:10 | 0.62 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.62 | 20.01 | 0.62 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.181176E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.174846E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.201818E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.208678E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.227167E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.221993E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.188169E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.205442E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.195426E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.190033E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.182224E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.179350E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.235632E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.174846E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.227167E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.157463E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.157253E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.193634E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.210541E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.235697E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.236517E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.196801E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.210715E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.193917E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.181519E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.165675E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.155453E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.229518E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.155453E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.236517E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.211854E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.200014E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.229467E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.221678E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.243829E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.238014E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.212022E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.231612E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.215560E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.217302E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.209386E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.207909E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.263865E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.200014E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.243829E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.157022E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.157067E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.192551E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.210059E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.235475E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.236317E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.196565E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.210806E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.194141E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.181153E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.165521E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.155126E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.229180E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.155126E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.236317E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.135742E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.133870E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.161997E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.177576E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.202024E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.202411E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.170177E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.180621E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.166814E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.158111E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.144486E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.135226E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.196905E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133870E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.202411E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.135742E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.133876E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.161971E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.177572E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.202031E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.202420E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.170183E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.180640E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.166839E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.158106E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.144493E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.135225E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.196910E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133876E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.202420E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.160632E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.152495E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.171042E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.176268E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.193869E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.188030E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.161883E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.175771E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.168926E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.167445E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.162037E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.160275E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.203867E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.152495E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.193869E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.172190E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.162844E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.182260E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.187971E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.206036E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.199645E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.173603E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.187096E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.180255E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.178965E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.173065E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.171134E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.217506E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.162844E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.206036E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.366741E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.354834E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.415433E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.427687E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.462446E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.447919E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.370384E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.410447E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.387667E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.383296E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.365950E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.359213E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.475202E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.354834E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.462446E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.314969E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.316758E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.397504E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.430669E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.479669E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.477980E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.387670E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.420691E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.383336E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.364134E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.329618E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.307035E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.461003E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.307035E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.479669E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.365636E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.354430E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.413115E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.426865E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.462369E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.448141E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.370392E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.411139E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.388432E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.382697E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.365537E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.358446E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.474720E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.354430E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.462369E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.313966E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.316410E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.395003E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.429542E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.479168E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.477677E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.387281E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.421050E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.383894E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.363434E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.329242E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.306398E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.460307E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.306398E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.479168E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.268575E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.265852E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.326001E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.356378E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.404608E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.403341E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.333162E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.356984E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.327140E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.313981E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.285141E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.265543E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.390671E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.265543E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.404608E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.268576E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.265871E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.325951E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.356373E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.404623E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.403362E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.333176E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.357025E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.327191E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.313976E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.285153E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.265546E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.390682E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.265546E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.404623E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.321053E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.304588E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.344317E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.353335E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.387030E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.372631E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.315539E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.346527E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.331518E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.333448E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.322012E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.318394E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.405039E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.304588E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.387030E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.321038E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.304593E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.344261E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.353330E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.387049E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.372660E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.315557E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.346569E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.331565E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.333437E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.322012E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.318382E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.405045E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.304593E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.387049E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.198785E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.195047E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.233915E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.243207E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.261440E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.254258E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.206064E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.227909E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.215838E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.209027E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.198450E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.192437E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.263638E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.192437E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.261440E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.171228E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.174941E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.224620E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.245067E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.270872E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.270452E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.215418E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.233537E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.213602E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.199038E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.179260E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.164628E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.256266E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.164628E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.270872E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.197826E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.194502E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.232102E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.242255E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.260931E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.254094E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.205880E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.228071E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.215970E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.208440E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.197917E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.191751E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.262974E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.191751E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.260931E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.170454E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.174532E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.222762E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.243951E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.270098E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.269933E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.214990E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.233505E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.213645E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.198455E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.178846E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.164144E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.255531E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.164144E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.270098E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.146349E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.147422E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.185551E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.204393E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.229409E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.229413E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.185843E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.198667E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.183151E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.172119E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.155474E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.142615E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.218041E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.142615E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.229413E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.146339E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.147424E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.185495E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.204361E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.229384E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.229395E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.185832E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.198670E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.183158E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.172102E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.155464E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.142612E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.218024E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.142612E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.229395E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.174445E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.167999E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.195177E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.202631E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.219924E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.213033E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.176433E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.193054E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.185530E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.182379E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.175063E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.170944E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.225661E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.167999E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.219924E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.174415E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.167984E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.195114E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.202599E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.219905E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.213026E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.176427E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.193060E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.185534E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.182354E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.175039E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.170919E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.225638E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.167984E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.219905E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.357291E+09 | 0.574906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.342047E+09 | 0.550104E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.391619E+09 | 0.633116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.400713E+09 | 0.655857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.435279E+09 | 0.722474E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.425658E+09 | 0.707379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.368549E+09 | 0.602076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.399470E+09 | 0.665594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.380448E+09 | 0.629234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.372962E+09 | 0.616021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.358649E+09 | 0.586750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.354628E+09 | 0.574316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.458731E+10 | 0.751783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.342047E+09 | 0.550104E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.435279E+09 | 0.722474E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.311606E+09 | 0.497449E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.308732E+09 | 0.492817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.377254E+09 | 0.606237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.406124E+09 | 0.661254E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.453807E+09 | 0.749630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.455808E+09 | 0.754347E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.387296E+09 | 0.629752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.411600E+09 | 0.682422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.379178E+09 | 0.623667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.357773E+09 | 0.587446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.327328E+09 | 0.532004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.308513E+09 | 0.495903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.448502E+10 | 0.731293E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.308513E+09 | 0.492817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.455808E+09 | 0.754347E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.116268E+10 | 0.385692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.105016E+10 | 0.379584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.116268E+10 | 0.448673E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.112517E+10 | 0.436150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.116268E+10 | 0.516977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.112517E+10 | 0.506951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.116268E+10 | 0.394771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.116268E+10 | 0.477639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.112517E+10 | 0.425551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.116268E+10 | 0.421105E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.112517E+10 | 0.399038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.116268E+10 | 0.372214E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.136896E+11 | 0.516434E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.105016E+10 | 0.372214E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.116268E+10 | 0.516977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.307788E+09 | 0.498134E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.305502E+09 | 0.494424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.371477E+09 | 0.605191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.401243E+09 | 0.662551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.448909E+09 | 0.752371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.450956E+09 | 0.757272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.383069E+09 | 0.631746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.407680E+09 | 0.685693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.375877E+09 | 0.627053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.353524E+09 | 0.588610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.323861E+09 | 0.533714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.304903E+09 | 0.496883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.443479E+10 | 0.733364E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.304903E+09 | 0.494424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.450956E+09 | 0.757272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.266109E+09 | 0.430857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260382E+09 | 0.421362E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.312594E+09 | 0.508436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.339082E+09 | 0.559424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.385181E+09 | 0.644842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386260E+09 | 0.647706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.331694E+09 | 0.546983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349436E+09 | 0.586998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.322995E+09 | 0.539067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.308664E+09 | 0.514299E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282739E+09 | 0.466481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.265860E+09 | 0.433724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.381100E+10 | 0.630018E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.260382E+09 | 0.421362E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.386260E+09 | 0.647706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.266044E+09 | 0.430898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260331E+09 | 0.421423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.312464E+09 | 0.508397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.338990E+09 | 0.559467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.385098E+09 | 0.644934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386181E+09 | 0.647807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.331624E+09 | 0.547060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349384E+09 | 0.587120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.322964E+09 | 0.539205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.308576E+09 | 0.514330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282683E+09 | 0.466549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.265792E+09 | 0.433761E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.381013E+10 | 0.630095E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.260331E+09 | 0.421423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.386181E+09 | 0.647807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.312850E+09 | 0.512408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.294642E+09 | 0.482114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.327711E+09 | 0.538122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.334008E+09 | 0.555933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.366682E+09 | 0.619075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.355859E+09 | 0.601427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.313035E+09 | 0.520528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.337429E+09 | 0.571715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.324612E+09 | 0.546725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.324459E+09 | 0.545763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.314877E+09 | 0.524794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.312957E+09 | 0.516260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.391912E+10 | 0.653486E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.294642E+09 | 0.482114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.366682E+09 | 0.619075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.336152E+09 | 0.550412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.315393E+09 | 0.515913E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.350028E+09 | 0.574473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.357049E+09 | 0.593707E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.390628E+09 | 0.658693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.378775E+09 | 0.639363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.336461E+09 | 0.558925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.359966E+09 | 0.609021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.347167E+09 | 0.583960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.347543E+09 | 0.583863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.337058E+09 | 0.561259E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.334903E+09 | 0.552170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.419112E+10 | 0.698176E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.315393E+09 | 0.515913E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.390628E+09 | 0.658693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.722476E+09 | 0.115873E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.693250E+09 | 0.111131E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.805241E+09 | 0.129927E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.820475E+09 | 0.134018E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.884932E+09 | 0.146659E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.857514E+09 | 0.142277E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.724454E+09 | 0.118033E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.797042E+09 | 0.132672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.753813E+09 | 0.124378E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.751660E+09 | 0.123871E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.719636E+09 | 0.117367E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.709524E+09 | 0.114505E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924002E+10 | 0.151071E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.693250E+09 | 0.111131E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.884932E+09 | 0.146659E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.622057E+09 | 0.991395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.620491E+09 | 0.988768E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.772845E+09 | 0.124116E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.829070E+09 | 0.134869E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.921328E+09 | 0.152111E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.918682E+09 | 0.151916E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.761067E+09 | 0.123538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.819792E+09 | 0.135930E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.747911E+09 | 0.122872E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.716439E+09 | 0.117530E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.650062E+09 | 0.105492E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.608145E+09 | 0.975786E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.898789E+10 | 0.146397E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.608145E+09 | 0.975786E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.921328E+09 | 0.152111E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.712266E+09 | 0.116090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.684903E+09 | 0.111581E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.791533E+09 | 0.129771E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.809481E+09 | 0.134377E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.874450E+09 | 0.147351E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.847953E+09 | 0.143049E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.716132E+09 | 0.118586E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.788943E+09 | 0.133510E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.746489E+09 | 0.125194E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.741721E+09 | 0.124231E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.710613E+09 | 0.117793E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.700001E+09 | 0.114810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.912448E+10 | 0.151634E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.684903E+09 | 0.111581E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.874450E+09 | 0.147351E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.613578E+09 | 0.992875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.613466E+09 | 0.992588E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.759628E+09 | 0.123860E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.817928E+09 | 0.135136E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.910239E+09 | 0.152709E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.908044E+09 | 0.152595E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.752064E+09 | 0.124000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.811355E+09 | 0.136682E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.740763E+09 | 0.123610E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.707182E+09 | 0.117812E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.642334E+09 | 0.105850E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.600419E+09 | 0.978192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.887700E+10 | 0.146862E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.600419E+09 | 0.978192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.910239E+09 | 0.152709E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.527246E+09 | 0.848841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.517701E+09 | 0.832906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.629837E+09 | 0.101925E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.681352E+09 | 0.111803E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.772149E+09 | 0.128583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.770233E+09 | 0.128439E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.650010E+09 | 0.106545E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.691347E+09 | 0.115590E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.634200E+09 | 0.105257E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.613907E+09 | 0.101745E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.558837E+09 | 0.916773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.522825E+09 | 0.848068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.756964E+10 | 0.124455E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.517701E+09 | 0.832906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.772149E+09 | 0.128583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.527104E+09 | 0.848924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.517601E+09 | 0.833052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.629563E+09 | 0.101918E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.681155E+09 | 0.111812E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.771964E+09 | 0.128602E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.770061E+09 | 0.128460E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649861E+09 | 0.106561E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.691233E+09 | 0.115616E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.634122E+09 | 0.105284E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.613727E+09 | 0.101754E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.558709E+09 | 0.916904E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.522688E+09 | 0.848158E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.756779E+10 | 0.124471E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.517601E+09 | 0.833052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.771964E+09 | 0.128602E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.626913E+09 | 0.101873E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.589930E+09 | 0.957623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.661392E+09 | 0.107856E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.671347E+09 | 0.110965E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.733826E+09 | 0.123073E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.706844E+09 | 0.118667E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.611698E+09 | 0.100970E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.666939E+09 | 0.112308E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.638755E+09 | 0.106806E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.648002E+09 | 0.108216E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.627511E+09 | 0.103770E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.623350E+09 | 0.102003E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.780651E+10 | 0.129227E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.589930E+09 | 0.957623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.733826E+09 | 0.123073E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.626699E+09 | 0.101880E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.589767E+09 | 0.957753E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.661082E+09 | 0.107848E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.671133E+09 | 0.110975E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.733639E+09 | 0.123092E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.706685E+09 | 0.118690E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.611550E+09 | 0.100986E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.666818E+09 | 0.112334E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.638654E+09 | 0.106833E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.647785E+09 | 0.108225E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.627324E+09 | 0.103782E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.623140E+09 | 0.102011E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.780428E+10 | 0.129243E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.589767E+09 | 0.957753E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.733639E+09 | 0.123092E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.390628E+09 | 0.627364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.380091E+09 | 0.610456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.452581E+09 | 0.731888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.466270E+09 | 0.762653E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.499824E+09 | 0.829475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.486289E+09 | 0.808187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.402511E+09 | 0.656471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.441960E+09 | 0.737184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.419232E+09 | 0.692396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.409349E+09 | 0.675340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.389643E+09 | 0.635919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.379130E+09 | 0.612410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.511751E+10 | 0.837974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.379130E+09 | 0.610456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.499824E+09 | 0.829475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.337279E+09 | 0.537332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.341776E+09 | 0.544854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.435931E+09 | 0.701075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.471460E+09 | 0.767774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.519777E+09 | 0.859329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.519292E+09 | 0.860407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.422336E+09 | 0.686312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.454448E+09 | 0.754982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.416282E+09 | 0.684228E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.391066E+09 | 0.641721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.352955E+09 | 0.572450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.325180E+09 | 0.521321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.498778E+10 | 0.813178E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.325180E+09 | 0.521321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.519777E+09 | 0.860407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.383766E+09 | 0.628549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.374291E+09 | 0.613077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.443111E+09 | 0.730680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.458282E+09 | 0.764557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.492122E+09 | 0.833605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.479436E+09 | 0.813344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.396803E+09 | 0.660121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.436216E+09 | 0.742534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.413831E+09 | 0.697278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.402684E+09 | 0.677617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.383471E+09 | 0.638392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.372867E+09 | 0.614291E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.503688E+10 | 0.841404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.372867E+09 | 0.613077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.492122E+09 | 0.833605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.331658E+09 | 0.538232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.336926E+09 | 0.547176E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.426824E+09 | 0.699337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.463360E+09 | 0.769161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.511619E+09 | 0.862919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.511645E+09 | 0.865014E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.416146E+09 | 0.689442E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.448447E+09 | 0.759856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.410998E+09 | 0.688685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.384880E+09 | 0.643603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.347701E+09 | 0.574617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.320196E+09 | 0.522944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.491040E+10 | 0.816099E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.320196E+09 | 0.522944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.511645E+09 | 0.865014E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.289220E+09 | 0.459788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288994E+09 | 0.459323E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.361186E+09 | 0.577867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.394212E+09 | 0.639268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.441534E+09 | 0.726803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.441826E+09 | 0.728774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.365511E+09 | 0.592310E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.387829E+09 | 0.641286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.358002E+09 | 0.586916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.339228E+09 | 0.555288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.307057E+09 | 0.497267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.282637E+09 | 0.452534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.425724E+10 | 0.691742E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.282637E+09 | 0.452534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.441826E+09 | 0.728774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.289043E+09 | 0.459868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288844E+09 | 0.459450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.360873E+09 | 0.577825E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.393929E+09 | 0.639332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.441239E+09 | 0.726933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.441546E+09 | 0.728937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.365286E+09 | 0.592436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.387615E+09 | 0.641469E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.357815E+09 | 0.587093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.339002E+09 | 0.555368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.306869E+09 | 0.497361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.282474E+09 | 0.452631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.425453E+10 | 0.691870E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.282474E+09 | 0.452631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.441546E+09 | 0.728937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.343397E+09 | 0.551309E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.328007E+09 | 0.526138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.378225E+09 | 0.609457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.388914E+09 | 0.634490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.421114E+09 | 0.697006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.408098E+09 | 0.676351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345244E+09 | 0.562443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.375035E+09 | 0.623682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.360914E+09 | 0.595520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.357730E+09 | 0.589703E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.344250E+09 | 0.561950E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.337364E+09 | 0.545187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.438829E+10 | 0.717324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.328007E+09 | 0.526138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.421114E+09 | 0.697006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.343137E+09 | 0.551373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.327790E+09 | 0.526252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.377875E+09 | 0.609416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.388619E+09 | 0.634558E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.420824E+09 | 0.697144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.407840E+09 | 0.676525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345028E+09 | 0.562576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.374818E+09 | 0.623870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.360706E+09 | 0.595698E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.357466E+09 | 0.589782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.344000E+09 | 0.562034E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.337117E+09 | 0.545266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.438522E+10 | 0.717449E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.327790E+09 | 0.526252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.420824E+09 | 0.697144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.357291E+09 | 0.00 | 0.00 | 0.00 | 0.145447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.342047E+09 | 0.00 | 0.00 | 0.00 | 0.140642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.391619E+09 | 0.00 | 0.00 | 0.00 | 0.162656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.400713E+09 | 0.00 | 0.00 | 0.00 | 0.168607E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.435279E+09 | 0.00 | 0.00 | 0.00 | 0.183639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.425658E+09 | 0.00 | 0.00 | 0.00 | 0.179427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.368549E+09 | 0.00 | 0.00 | 0.00 | 0.151314E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.399470E+09 | 0.00 | 0.00 | 0.00 | 0.165495E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.380448E+09 | 0.00 | 0.00 | 0.00 | 0.157382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.372962E+09 | 0.00 | 0.00 | 0.00 | 0.152736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.358649E+09 | 0.00 | 0.00 | 0.00 | 0.146359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.354628E+09 | 0.00 | 0.00 | 0.00 | 0.143887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.458731E+10 | 0.00 | 0.00 | 0.00 | 0.189759E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.342047E+09 | 0.00 | 0.00 | 0.00 | 0.140642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.435279E+09 | 0.00 | 0.00 | 0.00 | 0.183639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.311606E+09 | 0.00 | 0.00 | 0.00 | 0.126302E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.308732E+09 | 0.00 | 0.00 | 0.00 | 0.126379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.377254E+09 | 0.00 | 0.00 | 0.00 | 0.155908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.406124E+09 | 0.00 | 0.00 | 0.00 | 0.169929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.453807E+09 | 0.00 | 0.00 | 0.00 | 0.190317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.455808E+09 | 0.00 | 0.00 | 0.00 | 0.190936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.387296E+09 | 0.00 | 0.00 | 0.00 | 0.158072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.411600E+09 | 0.00 | 0.00 | 0.00 | 0.169555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.379178E+09 | 0.00 | 0.00 | 0.00 | 0.155999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.357773E+09 | 0.00 | 0.00 | 0.00 | 0.145742E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.327328E+09 | 0.00 | 0.00 | 0.00 | 0.132942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.308513E+09 | 0.00 | 0.00 | 0.00 | 0.124602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.448502E+10 | 0.00 | 0.00 | 0.00 | 0.184668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.308513E+09 | 0.00 | 0.00 | 0.00 | 0.124602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.455808E+09 | 0.00 | 0.00 | 0.00 | 0.190936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.955859E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.105016E+10 | 0.00 | 0.00 | 0.00 | 0.949984E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.113199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.112517E+10 | 0.00 | 0.00 | 0.00 | 0.109161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.127561E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.112517E+10 | 0.00 | 0.00 | 0.00 | 0.125496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.957540E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.115344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.112517E+10 | 0.00 | 0.00 | 0.00 | 0.103043E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.101035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.112517E+10 | 0.00 | 0.00 | 0.00 | 0.968686E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.916409E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.136896E+11 | 0.00 | 0.00 | 0.00 | 0.126969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.105016E+10 | 0.00 | 0.00 | 0.00 | 0.916409E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.116268E+10 | 0.00 | 0.00 | 0.00 | 0.127561E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.307788E+09 | 0.00 | 0.00 | 0.00 | 0.126243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.305502E+09 | 0.00 | 0.00 | 0.00 | 0.126517E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.371477E+09 | 0.00 | 0.00 | 0.00 | 0.155403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.401243E+09 | 0.00 | 0.00 | 0.00 | 0.169934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.448909E+09 | 0.00 | 0.00 | 0.00 | 0.190584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.450956E+09 | 0.00 | 0.00 | 0.00 | 0.191221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.383069E+09 | 0.00 | 0.00 | 0.00 | 0.158258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.407680E+09 | 0.00 | 0.00 | 0.00 | 0.170038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.375877E+09 | 0.00 | 0.00 | 0.00 | 0.156553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.353524E+09 | 0.00 | 0.00 | 0.00 | 0.145801E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.323861E+09 | 0.00 | 0.00 | 0.00 | 0.133135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.304903E+09 | 0.00 | 0.00 | 0.00 | 0.124635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.443479E+10 | 0.00 | 0.00 | 0.00 | 0.184832E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.304903E+09 | 0.00 | 0.00 | 0.00 | 0.124635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.450956E+09 | 0.00 | 0.00 | 0.00 | 0.191221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.266109E+09 | 0.00 | 0.00 | 0.00 | 0.109131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260382E+09 | 0.00 | 0.00 | 0.00 | 0.107832E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.312594E+09 | 0.00 | 0.00 | 0.00 | 0.130737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.339082E+09 | 0.00 | 0.00 | 0.00 | 0.143668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.385181E+09 | 0.00 | 0.00 | 0.00 | 0.163506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386260E+09 | 0.00 | 0.00 | 0.00 | 0.163785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.331694E+09 | 0.00 | 0.00 | 0.00 | 0.137008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349436E+09 | 0.00 | 0.00 | 0.00 | 0.145677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.322995E+09 | 0.00 | 0.00 | 0.00 | 0.134514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.308664E+09 | 0.00 | 0.00 | 0.00 | 0.127245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282739E+09 | 0.00 | 0.00 | 0.00 | 0.116212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.265860E+09 | 0.00 | 0.00 | 0.00 | 0.108640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.381100E+10 | 0.00 | 0.00 | 0.00 | 0.158796E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.260382E+09 | 0.00 | 0.00 | 0.00 | 0.107832E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.386260E+09 | 0.00 | 0.00 | 0.00 | 0.163785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.266044E+09 | 0.00 | 0.00 | 0.00 | 0.109138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260331E+09 | 0.00 | 0.00 | 0.00 | 0.107843E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.312464E+09 | 0.00 | 0.00 | 0.00 | 0.130725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.338990E+09 | 0.00 | 0.00 | 0.00 | 0.143673E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.385098E+09 | 0.00 | 0.00 | 0.00 | 0.163521E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386181E+09 | 0.00 | 0.00 | 0.00 | 0.163802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.331624E+09 | 0.00 | 0.00 | 0.00 | 0.137021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349384E+09 | 0.00 | 0.00 | 0.00 | 0.145701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.322964E+09 | 0.00 | 0.00 | 0.00 | 0.134543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.308576E+09 | 0.00 | 0.00 | 0.00 | 0.127248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282683E+09 | 0.00 | 0.00 | 0.00 | 0.116224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.265792E+09 | 0.00 | 0.00 | 0.00 | 0.108646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.381013E+10 | 0.00 | 0.00 | 0.00 | 0.158809E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.260331E+09 | 0.00 | 0.00 | 0.00 | 0.107843E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.386181E+09 | 0.00 | 0.00 | 0.00 | 0.163802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.312850E+09 | 0.00 | 0.00 | 0.00 | 0.129347E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.294642E+09 | 0.00 | 0.00 | 0.00 | 0.123031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.327711E+09 | 0.00 | 0.00 | 0.00 | 0.138271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.334008E+09 | 0.00 | 0.00 | 0.00 | 0.142867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.366682E+09 | 0.00 | 0.00 | 0.00 | 0.157201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.355859E+09 | 0.00 | 0.00 | 0.00 | 0.152444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.313035E+09 | 0.00 | 0.00 | 0.00 | 0.130579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.337429E+09 | 0.00 | 0.00 | 0.00 | 0.142028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.324612E+09 | 0.00 | 0.00 | 0.00 | 0.136465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.324459E+09 | 0.00 | 0.00 | 0.00 | 0.134999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.314877E+09 | 0.00 | 0.00 | 0.00 | 0.130549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.312957E+09 | 0.00 | 0.00 | 0.00 | 0.128979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.391912E+10 | 0.00 | 0.00 | 0.00 | 0.164676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.294642E+09 | 0.00 | 0.00 | 0.00 | 0.123031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.366682E+09 | 0.00 | 0.00 | 0.00 | 0.157201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.336152E+09 | 0.00 | 0.00 | 0.00 | 0.138575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.315393E+09 | 0.00 | 0.00 | 0.00 | 0.131305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.350028E+09 | 0.00 | 0.00 | 0.00 | 0.147257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.357049E+09 | 0.00 | 0.00 | 0.00 | 0.152266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.390628E+09 | 0.00 | 0.00 | 0.00 | 0.166973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.378775E+09 | 0.00 | 0.00 | 0.00 | 0.161768E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.336461E+09 | 0.00 | 0.00 | 0.00 | 0.139957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.359966E+09 | 0.00 | 0.00 | 0.00 | 0.151099E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.347167E+09 | 0.00 | 0.00 | 0.00 | 0.145538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.347543E+09 | 0.00 | 0.00 | 0.00 | 0.144211E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.337058E+09 | 0.00 | 0.00 | 0.00 | 0.139359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.334903E+09 | 0.00 | 0.00 | 0.00 | 0.137644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.419112E+10 | 0.00 | 0.00 | 0.00 | 0.175595E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.315393E+09 | 0.00 | 0.00 | 0.00 | 0.131305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.390628E+09 | 0.00 | 0.00 | 0.00 | 0.166973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.722476E+09 | 0.00 | 0.00 | 0.00 | 0.294494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.693250E+09 | 0.00 | 0.00 | 0.00 | 0.285509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.805241E+09 | 0.00 | 0.00 | 0.00 | 0.334909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.820475E+09 | 0.00 | 0.00 | 0.00 | 0.345639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.884932E+09 | 0.00 | 0.00 | 0.00 | 0.373953E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.857514E+09 | 0.00 | 0.00 | 0.00 | 0.362168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.724454E+09 | 0.00 | 0.00 | 0.00 | 0.297939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.797042E+09 | 0.00 | 0.00 | 0.00 | 0.330743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.753813E+09 | 0.00 | 0.00 | 0.00 | 0.312286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.751660E+09 | 0.00 | 0.00 | 0.00 | 0.308130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.719636E+09 | 0.00 | 0.00 | 0.00 | 0.293987E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.709524E+09 | 0.00 | 0.00 | 0.00 | 0.288261E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924002E+10 | 0.00 | 0.00 | 0.00 | 0.382802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.693250E+09 | 0.00 | 0.00 | 0.00 | 0.285509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.884932E+09 | 0.00 | 0.00 | 0.00 | 0.373953E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.622057E+09 | 0.00 | 0.00 | 0.00 | 0.252763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.620491E+09 | 0.00 | 0.00 | 0.00 | 0.254709E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.772845E+09 | 0.00 | 0.00 | 0.00 | 0.320220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.829070E+09 | 0.00 | 0.00 | 0.00 | 0.347762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.921328E+09 | 0.00 | 0.00 | 0.00 | 0.387536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.918682E+09 | 0.00 | 0.00 | 0.00 | 0.386112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.761067E+09 | 0.00 | 0.00 | 0.00 | 0.311563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.819792E+09 | 0.00 | 0.00 | 0.00 | 0.338712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.747911E+09 | 0.00 | 0.00 | 0.00 | 0.308545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.716439E+09 | 0.00 | 0.00 | 0.00 | 0.292490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.650062E+09 | 0.00 | 0.00 | 0.00 | 0.264612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.608145E+09 | 0.00 | 0.00 | 0.00 | 0.246221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.898789E+10 | 0.00 | 0.00 | 0.00 | 0.371124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.608145E+09 | 0.00 | 0.00 | 0.00 | 0.246221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.921328E+09 | 0.00 | 0.00 | 0.00 | 0.387536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.712266E+09 | 0.00 | 0.00 | 0.00 | 0.294409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.684903E+09 | 0.00 | 0.00 | 0.00 | 0.285939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.791533E+09 | 0.00 | 0.00 | 0.00 | 0.333961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.809481E+09 | 0.00 | 0.00 | 0.00 | 0.345917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.874450E+09 | 0.00 | 0.00 | 0.00 | 0.374924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.847953E+09 | 0.00 | 0.00 | 0.00 | 0.363345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.716132E+09 | 0.00 | 0.00 | 0.00 | 0.298779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.788943E+09 | 0.00 | 0.00 | 0.00 | 0.332244E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.746489E+09 | 0.00 | 0.00 | 0.00 | 0.313783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.741721E+09 | 0.00 | 0.00 | 0.00 | 0.308525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.710613E+09 | 0.00 | 0.00 | 0.00 | 0.294476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.700001E+09 | 0.00 | 0.00 | 0.00 | 0.288446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.912448E+10 | 0.00 | 0.00 | 0.00 | 0.383475E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.684903E+09 | 0.00 | 0.00 | 0.00 | 0.285939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.874450E+09 | 0.00 | 0.00 | 0.00 | 0.374924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.613578E+09 | 0.00 | 0.00 | 0.00 | 0.252609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.613466E+09 | 0.00 | 0.00 | 0.00 | 0.255063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.759628E+09 | 0.00 | 0.00 | 0.00 | 0.319040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.817928E+09 | 0.00 | 0.00 | 0.00 | 0.347749E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.910239E+09 | 0.00 | 0.00 | 0.00 | 0.388144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.908044E+09 | 0.00 | 0.00 | 0.00 | 0.386873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.752064E+09 | 0.00 | 0.00 | 0.00 | 0.312075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.811355E+09 | 0.00 | 0.00 | 0.00 | 0.339914E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.740763E+09 | 0.00 | 0.00 | 0.00 | 0.309818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.707182E+09 | 0.00 | 0.00 | 0.00 | 0.292716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.642334E+09 | 0.00 | 0.00 | 0.00 | 0.265009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.600419E+09 | 0.00 | 0.00 | 0.00 | 0.246357E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.887700E+10 | 0.00 | 0.00 | 0.00 | 0.371537E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.600419E+09 | 0.00 | 0.00 | 0.00 | 0.246357E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.910239E+09 | 0.00 | 0.00 | 0.00 | 0.388144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.527246E+09 | 0.00 | 0.00 | 0.00 | 0.215850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.517701E+09 | 0.00 | 0.00 | 0.00 | 0.214081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.629837E+09 | 0.00 | 0.00 | 0.00 | 0.263018E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.681352E+09 | 0.00 | 0.00 | 0.00 | 0.288243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.772149E+09 | 0.00 | 0.00 | 0.00 | 0.327393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.770233E+09 | 0.00 | 0.00 | 0.00 | 0.326318E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.650010E+09 | 0.00 | 0.00 | 0.00 | 0.268161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.691347E+09 | 0.00 | 0.00 | 0.00 | 0.287850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.634200E+09 | 0.00 | 0.00 | 0.00 | 0.263720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.613907E+09 | 0.00 | 0.00 | 0.00 | 0.252590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.558837E+09 | 0.00 | 0.00 | 0.00 | 0.229258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.522825E+09 | 0.00 | 0.00 | 0.00 | 0.213260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.756964E+10 | 0.00 | 0.00 | 0.00 | 0.314974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.517701E+09 | 0.00 | 0.00 | 0.00 | 0.213260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.772149E+09 | 0.00 | 0.00 | 0.00 | 0.327393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.527104E+09 | 0.00 | 0.00 | 0.00 | 0.215865E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.517601E+09 | 0.00 | 0.00 | 0.00 | 0.214111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.629563E+09 | 0.00 | 0.00 | 0.00 | 0.262995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.681155E+09 | 0.00 | 0.00 | 0.00 | 0.288258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.771964E+09 | 0.00 | 0.00 | 0.00 | 0.327426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.770061E+09 | 0.00 | 0.00 | 0.00 | 0.326356E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649861E+09 | 0.00 | 0.00 | 0.00 | 0.268190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.691233E+09 | 0.00 | 0.00 | 0.00 | 0.287901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.634122E+09 | 0.00 | 0.00 | 0.00 | 0.263778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.613727E+09 | 0.00 | 0.00 | 0.00 | 0.252603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.558709E+09 | 0.00 | 0.00 | 0.00 | 0.229282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.522688E+09 | 0.00 | 0.00 | 0.00 | 0.213277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.756779E+10 | 0.00 | 0.00 | 0.00 | 0.315004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.517601E+09 | 0.00 | 0.00 | 0.00 | 0.213277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.771964E+09 | 0.00 | 0.00 | 0.00 | 0.327426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.626913E+09 | 0.00 | 0.00 | 0.00 | 0.258361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.589930E+09 | 0.00 | 0.00 | 0.00 | 0.245595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.661392E+09 | 0.00 | 0.00 | 0.00 | 0.278178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.671347E+09 | 0.00 | 0.00 | 0.00 | 0.286200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.733826E+09 | 0.00 | 0.00 | 0.00 | 0.313647E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.706844E+09 | 0.00 | 0.00 | 0.00 | 0.301947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.611698E+09 | 0.00 | 0.00 | 0.00 | 0.254369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.666939E+09 | 0.00 | 0.00 | 0.00 | 0.279833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.638755E+09 | 0.00 | 0.00 | 0.00 | 0.267642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.648002E+09 | 0.00 | 0.00 | 0.00 | 0.268648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.627511E+09 | 0.00 | 0.00 | 0.00 | 0.259261E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.623350E+09 | 0.00 | 0.00 | 0.00 | 0.256059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.780651E+10 | 0.00 | 0.00 | 0.00 | 0.326974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.589930E+09 | 0.00 | 0.00 | 0.00 | 0.245595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.733826E+09 | 0.00 | 0.00 | 0.00 | 0.313647E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.626699E+09 | 0.00 | 0.00 | 0.00 | 0.258368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.589767E+09 | 0.00 | 0.00 | 0.00 | 0.245616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.661082E+09 | 0.00 | 0.00 | 0.00 | 0.278153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.671133E+09 | 0.00 | 0.00 | 0.00 | 0.286216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.733639E+09 | 0.00 | 0.00 | 0.00 | 0.313685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.706685E+09 | 0.00 | 0.00 | 0.00 | 0.301991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.611550E+09 | 0.00 | 0.00 | 0.00 | 0.254402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.666818E+09 | 0.00 | 0.00 | 0.00 | 0.279888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.638654E+09 | 0.00 | 0.00 | 0.00 | 0.267700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.647785E+09 | 0.00 | 0.00 | 0.00 | 0.268658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.627324E+09 | 0.00 | 0.00 | 0.00 | 0.259280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.623140E+09 | 0.00 | 0.00 | 0.00 | 0.256068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.780428E+10 | 0.00 | 0.00 | 0.00 | 0.327002E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.589767E+09 | 0.00 | 0.00 | 0.00 | 0.245616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.733639E+09 | 0.00 | 0.00 | 0.00 | 0.313685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.390628E+09 | 0.00 | 0.00 | 0.00 | 0.159723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.380091E+09 | 0.00 | 0.00 | 0.00 | 0.157038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.452581E+09 | 0.00 | 0.00 | 0.00 | 0.188657E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.466270E+09 | 0.00 | 0.00 | 0.00 | 0.196580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.499824E+09 | 0.00 | 0.00 | 0.00 | 0.211458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.486289E+09 | 0.00 | 0.00 | 0.00 | 0.205629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.402511E+09 | 0.00 | 0.00 | 0.00 | 0.165813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.441960E+09 | 0.00 | 0.00 | 0.00 | 0.183713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.419232E+09 | 0.00 | 0.00 | 0.00 | 0.173915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.409349E+09 | 0.00 | 0.00 | 0.00 | 0.168092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.389643E+09 | 0.00 | 0.00 | 0.00 | 0.159485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.379130E+09 | 0.00 | 0.00 | 0.00 | 0.154524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.511751E+10 | 0.00 | 0.00 | 0.00 | 0.212463E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.379130E+09 | 0.00 | 0.00 | 0.00 | 0.154524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.499824E+09 | 0.00 | 0.00 | 0.00 | 0.211458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.337279E+09 | 0.00 | 0.00 | 0.00 | 0.137500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.341776E+09 | 0.00 | 0.00 | 0.00 | 0.140763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.435931E+09 | 0.00 | 0.00 | 0.00 | 0.181027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.471460E+09 | 0.00 | 0.00 | 0.00 | 0.197921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.519777E+09 | 0.00 | 0.00 | 0.00 | 0.218894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.519292E+09 | 0.00 | 0.00 | 0.00 | 0.218523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.422336E+09 | 0.00 | 0.00 | 0.00 | 0.173185E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.454448E+09 | 0.00 | 0.00 | 0.00 | 0.188092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.416282E+09 | 0.00 | 0.00 | 0.00 | 0.171974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.391066E+09 | 0.00 | 0.00 | 0.00 | 0.159932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.352955E+09 | 0.00 | 0.00 | 0.00 | 0.143965E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.325180E+09 | 0.00 | 0.00 | 0.00 | 0.132110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.498778E+10 | 0.00 | 0.00 | 0.00 | 0.206389E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.325180E+09 | 0.00 | 0.00 | 0.00 | 0.132110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.519777E+09 | 0.00 | 0.00 | 0.00 | 0.218894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.383766E+09 | 0.00 | 0.00 | 0.00 | 0.159450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.374291E+09 | 0.00 | 0.00 | 0.00 | 0.157073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.443111E+09 | 0.00 | 0.00 | 0.00 | 0.187791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.458282E+09 | 0.00 | 0.00 | 0.00 | 0.196427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.492122E+09 | 0.00 | 0.00 | 0.00 | 0.211719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.479436E+09 | 0.00 | 0.00 | 0.00 | 0.206150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.396803E+09 | 0.00 | 0.00 | 0.00 | 0.166199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.436216E+09 | 0.00 | 0.00 | 0.00 | 0.184450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.413831E+09 | 0.00 | 0.00 | 0.00 | 0.174587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.402684E+09 | 0.00 | 0.00 | 0.00 | 0.168172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.383471E+09 | 0.00 | 0.00 | 0.00 | 0.159570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.372867E+09 | 0.00 | 0.00 | 0.00 | 0.154464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.503688E+10 | 0.00 | 0.00 | 0.00 | 0.212605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.372867E+09 | 0.00 | 0.00 | 0.00 | 0.154464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.492122E+09 | 0.00 | 0.00 | 0.00 | 0.211719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.331658E+09 | 0.00 | 0.00 | 0.00 | 0.137288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.336926E+09 | 0.00 | 0.00 | 0.00 | 0.140840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.426824E+09 | 0.00 | 0.00 | 0.00 | 0.180080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.463360E+09 | 0.00 | 0.00 | 0.00 | 0.197615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.511619E+09 | 0.00 | 0.00 | 0.00 | 0.218936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.511645E+09 | 0.00 | 0.00 | 0.00 | 0.218769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.416146E+09 | 0.00 | 0.00 | 0.00 | 0.173375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.448447E+09 | 0.00 | 0.00 | 0.00 | 0.188660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.410998E+09 | 0.00 | 0.00 | 0.00 | 0.172545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.384880E+09 | 0.00 | 0.00 | 0.00 | 0.159967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.347701E+09 | 0.00 | 0.00 | 0.00 | 0.144076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.320196E+09 | 0.00 | 0.00 | 0.00 | 0.132124E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.491040E+10 | 0.00 | 0.00 | 0.00 | 0.206427E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.320196E+09 | 0.00 | 0.00 | 0.00 | 0.132124E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.511645E+09 | 0.00 | 0.00 | 0.00 | 0.218936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.289220E+09 | 0.00 | 0.00 | 0.00 | 0.117427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288994E+09 | 0.00 | 0.00 | 0.00 | 0.118522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.361186E+09 | 0.00 | 0.00 | 0.00 | 0.149433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.394212E+09 | 0.00 | 0.00 | 0.00 | 0.164972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.441534E+09 | 0.00 | 0.00 | 0.00 | 0.185256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.441826E+09 | 0.00 | 0.00 | 0.00 | 0.185230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.365511E+09 | 0.00 | 0.00 | 0.00 | 0.149292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.387829E+09 | 0.00 | 0.00 | 0.00 | 0.159884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.358002E+09 | 0.00 | 0.00 | 0.00 | 0.147351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.339228E+09 | 0.00 | 0.00 | 0.00 | 0.138196E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.307057E+09 | 0.00 | 0.00 | 0.00 | 0.124768E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.282637E+09 | 0.00 | 0.00 | 0.00 | 0.114351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.425724E+10 | 0.00 | 0.00 | 0.00 | 0.175468E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.282637E+09 | 0.00 | 0.00 | 0.00 | 0.114351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.441826E+09 | 0.00 | 0.00 | 0.00 | 0.185256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.289043E+09 | 0.00 | 0.00 | 0.00 | 0.117435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288844E+09 | 0.00 | 0.00 | 0.00 | 0.118540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.360873E+09 | 0.00 | 0.00 | 0.00 | 0.149408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.393929E+09 | 0.00 | 0.00 | 0.00 | 0.164968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.441239E+09 | 0.00 | 0.00 | 0.00 | 0.185260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.441546E+09 | 0.00 | 0.00 | 0.00 | 0.185241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.365286E+09 | 0.00 | 0.00 | 0.00 | 0.149303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.387615E+09 | 0.00 | 0.00 | 0.00 | 0.159908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.357815E+09 | 0.00 | 0.00 | 0.00 | 0.147377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.339002E+09 | 0.00 | 0.00 | 0.00 | 0.138201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.306869E+09 | 0.00 | 0.00 | 0.00 | 0.124778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.282474E+09 | 0.00 | 0.00 | 0.00 | 0.114364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.425453E+10 | 0.00 | 0.00 | 0.00 | 0.175478E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.282474E+09 | 0.00 | 0.00 | 0.00 | 0.114364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.441546E+09 | 0.00 | 0.00 | 0.00 | 0.185260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.343397E+09 | 0.00 | 0.00 | 0.00 | 0.140106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.328007E+09 | 0.00 | 0.00 | 0.00 | 0.135198E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.378225E+09 | 0.00 | 0.00 | 0.00 | 0.157355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.388914E+09 | 0.00 | 0.00 | 0.00 | 0.163740E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.421114E+09 | 0.00 | 0.00 | 0.00 | 0.177813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.408098E+09 | 0.00 | 0.00 | 0.00 | 0.172223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345244E+09 | 0.00 | 0.00 | 0.00 | 0.141909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.375035E+09 | 0.00 | 0.00 | 0.00 | 0.155551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.360914E+09 | 0.00 | 0.00 | 0.00 | 0.149439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.357730E+09 | 0.00 | 0.00 | 0.00 | 0.146606E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.344250E+09 | 0.00 | 0.00 | 0.00 | 0.140638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.337364E+09 | 0.00 | 0.00 | 0.00 | 0.137208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.438829E+10 | 0.00 | 0.00 | 0.00 | 0.181778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.328007E+09 | 0.00 | 0.00 | 0.00 | 0.135198E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.421114E+09 | 0.00 | 0.00 | 0.00 | 0.177813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.343137E+09 | 0.00 | 0.00 | 0.00 | 0.140101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.327790E+09 | 0.00 | 0.00 | 0.00 | 0.135205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.377875E+09 | 0.00 | 0.00 | 0.00 | 0.157327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.388619E+09 | 0.00 | 0.00 | 0.00 | 0.163737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.420824E+09 | 0.00 | 0.00 | 0.00 | 0.177822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.407840E+09 | 0.00 | 0.00 | 0.00 | 0.172242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345028E+09 | 0.00 | 0.00 | 0.00 | 0.141924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.374818E+09 | 0.00 | 0.00 | 0.00 | 0.155578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.360706E+09 | 0.00 | 0.00 | 0.00 | 0.149464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.357466E+09 | 0.00 | 0.00 | 0.00 | 0.146607E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.344000E+09 | 0.00 | 0.00 | 0.00 | 0.140639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.337117E+09 | 0.00 | 0.00 | 0.00 | 0.137208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.438522E+10 | 0.00 | 0.00 | 0.00 | 0.181785E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.327790E+09 | 0.00 | 0.00 | 0.00 | 0.135205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.420824E+09 | 0.00 | 0.00 | 0.00 | 0.177822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.123873E+10 | 0.00 | 85947.69 | 0.00 | 0.00 | 1219044.53 | 0.00 | 0.36 |
| February | 0.00 | 0.126535E+10 | 0.00 | 4113.11 | 0.00 | 0.00 | 152498.39 | 0.00 | 0.36 |
| March | 0.00 | 0.154235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.193463E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.229147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.222190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.167720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.203896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.194742E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.184465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.159392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.132633E+10 | 0.00 | 26108.69 | 0.00 | 0.00 | 834120.16 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.209229E+11 | 0.00 | 116169.49 | 0.00 | 0.00 | 2205663.09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.123873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.229147E+10 | 0.00 | 85947.69 | 0.00 | 0.00 | 1219044.53 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.117672E+10 | 0.00 | 89343.80 | 0.00 | 0.00 | 2136713.26 | 0.00 | 0.36 |
| February | 0.00 | 0.121919E+10 | 0.00 | 8492.03 | 0.00 | 0.00 | 210349.81 | 0.00 | 0.36 |
| March | 0.00 | 0.151840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.193762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.231518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.226322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.170117E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.205377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.194006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.181218E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.153901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.125579E+10 | 0.00 | 25621.62 | 0.00 | 0.00 | 1175345.42 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.207323E+11 | 0.00 | 123457.45 | 0.00 | 0.00 | 3522408.49 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.117672E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.231518E+10 | 0.00 | 89343.80 | 0.00 | 0.00 | 2136713.26 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.266330E+09 | 0.638924E+09 | 0.00 | 299723.48 | 88594063.40 | 0.00 | 11872884.81 | 0.00 | 0.54 |
| February | 0.169492E+09 | 0.665591E+09 | 0.00 | 352789.75 | 95848508.82 | 0.00 | 12956897.90 | 0.00 | 0.54 |
| March | 0.117092E+09 | 0.859521E+09 | 0.00 | 120846.46 | 0.124545E+09 | 0.00 | 2887696.09 | 0.00 | 0.54 |
| April | 72382060.84 | 0.990195E+09 | 0.00 | 89311.79 | 0.209036E+09 | 0.00 | 443150.70 | 0.00 | 0.54 |
| May | 86466909.28 | 0.130625E+10 | 0.00 | 54030.02 | 0.278496E+09 | 0.00 | 955056.68 | 0.00 | 0.54 |
| June | 0.101118E+09 | 0.130384E+10 | 0.00 | 89128.87 | 0.250133E+09 | 0.00 | 751752.63 | 0.00 | 0.54 |
| July | 0.126003E+09 | 0.787780E+09 | 0.00 | 121808.64 | 0.149807E+09 | 0.00 | 3892201.11 | 0.00 | 0.54 |
| August | 0.141522E+09 | 0.116833E+10 | 0.00 | 69317.65 | 0.213415E+09 | 0.00 | 1286280.89 | 0.00 | 0.54 |
| September | 0.127287E+09 | 0.101715E+10 | 0.00 | 84265.33 | 0.187492E+09 | 0.00 | 2230397.97 | 0.00 | 0.54 |
| October | 0.158160E+09 | 0.953799E+09 | 0.00 | 88958.08 | 0.170095E+09 | 0.00 | 2348889.43 | 0.00 | 0.54 |
| November | 0.205923E+09 | 0.836252E+09 | 0.00 | 122259.48 | 0.138275E+09 | 0.00 | 3177216.27 | 0.00 | 0.54 |
| December | 0.288498E+09 | 0.644926E+09 | 0.00 | 339743.74 | 0.104689E+09 | 0.00 | 9172299.90 | 0.00 | 0.54 |
| Annual Sum or Average | 0.186028E+10 | 0.111726E+11 | 0.00 | 1832183.29 | 0.201043E+10 | 0.00 | 51974724.39 | 0.00 | 0.54 |
| Minimum of Months | 72382060.84 | 0.638924E+09 | 0.00 | 54030.02 | 88594063.40 | 0.00 | 443150.70 | 0.00 | 0.54 |
| Maximum of Months | 0.288498E+09 | 0.130625E+10 | 0.00 | 352789.75 | 0.278496E+09 | 0.00 | 12956897.90 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.118581E+10 | 0.00 | 94578.64 | 0.00 | 0.00 | 1920148.32 | 0.00 | 0.36 |
| February | 0.00 | 0.122843E+10 | 0.00 | 7982.45 | 0.00 | 0.00 | 206166.82 | 0.00 | 0.36 |
| March | 0.00 | 0.152525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.194690E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.232496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.227374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.171115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.206396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.195073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.182019E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.154785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.126461E+10 | 0.00 | 26789.51 | 0.00 | 0.00 | 1120175.10 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.208436E+11 | 0.00 | 129350.59 | 0.00 | 0.00 | 3246490.25 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.118581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.232496E+10 | 0.00 | 94578.64 | 0.00 | 0.00 | 1920148.32 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.115889E+10 | 0.00 | 86754.73 | 0.00 | 0.00 | 1973821.45 | 0.00 | 0.36 |
| February | 0.00 | 0.119768E+10 | 0.00 | 9345.62 | 0.00 | 0.00 | 237252.51 | 0.00 | 0.36 |
| March | 0.00 | 0.150012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.190804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.229372E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.223985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.167522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.203182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.190458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.178478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.151309E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.123436E+10 | 0.00 | 23567.78 | 0.00 | 0.00 | 988603.69 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.204421E+11 | 0.00 | 119668.13 | 0.00 | 0.00 | 3199677.65 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.115889E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.229372E+10 | 0.00 | 86754.73 | 0.00 | 0.00 | 1973821.45 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.115905E+10 | 0.00 | 86938.29 | 0.00 | 0.00 | 1970028.50 | 0.00 | 0.36 |
| February | 0.00 | 0.119787E+10 | 0.00 | 9343.85 | 0.00 | 0.00 | 237736.40 | 0.00 | 0.36 |
| March | 0.00 | 0.150017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.190821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.229393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.224010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.167545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.203210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.190487E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.178492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.151329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.123451E+10 | 0.00 | 23587.10 | 0.00 | 0.00 | 987559.32 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.204445E+11 | 0.00 | 119869.24 | 0.00 | 0.00 | 3195324.21 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.115905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.229393E+10 | 0.00 | 86938.29 | 0.00 | 0.00 | 1970028.50 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.123924E+10 | 0.00 | 71190.11 | 0.00 | 0.00 | 904874.70 | 0.00 | 0.36 |
| February | 0.00 | 0.125922E+10 | 0.00 | 3829.14 | 0.00 | 0.00 | 153815.19 | 0.00 | 0.36 |
| March | 0.00 | 0.153547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.190973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.227001E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.219358E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.165133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.201895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.191924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.183001E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.158488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.132442E+10 | 0.00 | 23086.87 | 0.00 | 0.00 | 616475.54 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.207361E+11 | 0.00 | 98106.12 | 0.00 | 0.00 | 1675165.43 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.123924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.227001E+10 | 0.00 | 71190.11 | 0.00 | 0.00 | 904874.70 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.127493E+10 | 0.00 | 59095.92 | 0.00 | 0.00 | 422011.41 | 0.00 | 0.36 |
| February | 0.00 | 0.129064E+10 | 0.00 | 3668.64 | 0.00 | 0.00 | 120454.33 | 0.00 | 0.36 |
| March | 0.00 | 0.157210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.195362E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.232027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.224159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.169719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.206897E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.196723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.187902E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.162646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.136178E+10 | 0.00 | 20027.40 | 0.00 | 0.00 | 459295.68 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.212538E+11 | 0.00 | 82791.97 | 0.00 | 0.00 | 1001761.42 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.127493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.232027E+10 | 0.00 | 59095.92 | 0.00 | 0.00 | 459295.68 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.239338E+10 | 0.00 | 187561.39 | 0.00 | 0.00 | 5047569.16 | 0.00 | 0.36 |
| February | 0.00 | 0.245386E+10 | 0.00 | 18348.13 | 0.00 | 0.00 | 437229.10 | 0.00 | 0.36 |
| March | 0.00 | 0.297759E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.375800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.443026E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.428414E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.321745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.389773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.375208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.357049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.308689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.255453E+10 | 0.00 | 64736.53 | 0.00 | 0.00 | 2964664.30 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.403764E+11 | 0.00 | 270646.05 | 0.00 | 0.00 | 8449462.56 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.239338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.443026E+10 | 0.00 | 187561.39 | 0.00 | 0.00 | 5047569.16 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.226505E+10 | 0.00 | 185198.14 | 0.00 | 0.00 | 7282528.31 | 0.00 | 0.36 |
| February | 0.00 | 0.235945E+10 | 0.00 | 29921.31 | 0.00 | 0.00 | 619105.83 | 0.00 | 0.36 |
| March | 0.00 | 0.292976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.376268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.447785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.436962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.326681E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.392715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.373427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.350154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.297119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.240735E+10 | 0.00 | 74203.98 | 0.00 | 0.00 | 4168567.24 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.399727E+11 | 0.00 | 289323.43 | 0.00 | 0.00 | 12070201.38 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.226505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.447785E+10 | 0.00 | 185198.14 | 0.00 | 0.00 | 7282528.31 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.241888E+10 | 0.00 | 210574.67 | 0.00 | 0.00 | 4463618.52 | 0.00 | 0.36 |
| February | 0.00 | 0.247898E+10 | 0.00 | 13665.41 | 0.00 | 0.00 | 419405.77 | 0.00 | 0.36 |
| March | 0.00 | 0.299763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.378321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.445585E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.431155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.324351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.392332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.377952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.359279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.311063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.257939E+10 | 0.00 | 66707.89 | 0.00 | 0.00 | 2836777.17 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.406753E+11 | 0.00 | 290947.97 | 0.00 | 0.00 | 7719801.47 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.241888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.445585E+10 | 0.00 | 210574.67 | 0.00 | 0.00 | 4463618.52 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.228426E+10 | 0.00 | 200965.52 | 0.00 | 0.00 | 6815844.98 | 0.00 | 0.36 |
| February | 0.00 | 0.237910E+10 | 0.00 | 30809.20 | 0.00 | 0.00 | 581263.61 | 0.00 | 0.36 |
| March | 0.00 | 0.294347E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.378186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.449753E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.439125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.328688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.394739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.375589E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.351773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.298868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.242593E+10 | 0.00 | 69872.37 | 0.00 | 0.00 | 4038260.08 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.402000E+11 | 0.00 | 301647.09 | 0.00 | 0.00 | 11435368.67 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.228426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.449753E+10 | 0.00 | 200965.52 | 0.00 | 0.00 | 6815844.98 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.224447E+10 | 0.00 | 182475.52 | 0.00 | 0.00 | 6101528.51 | 0.00 | 0.36 |
| February | 0.00 | 0.232780E+10 | 0.00 | 29802.44 | 0.00 | 0.00 | 656198.78 | 0.00 | 0.36 |
| March | 0.00 | 0.290893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.371850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.445864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.434784E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.323813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.391622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.368834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.346877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.293821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.238483E+10 | 0.00 | 71695.09 | 0.00 | 0.00 | 3115625.60 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.396407E+11 | 0.00 | 283973.05 | 0.00 | 0.00 | 9873352.89 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.224447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.445864E+10 | 0.00 | 182475.52 | 0.00 | 0.00 | 6101528.51 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.224481E+10 | 0.00 | 183031.95 | 0.00 | 0.00 | 6100714.69 | 0.00 | 0.36 |
| February | 0.00 | 0.232817E+10 | 0.00 | 29818.67 | 0.00 | 0.00 | 658116.38 | 0.00 | 0.36 |
| March | 0.00 | 0.290902E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.371883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.445905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.434831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.323857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.391675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.368891E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.346908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.293859E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.238513E+10 | 0.00 | 71600.43 | 0.00 | 0.00 | 3116574.30 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.396452E+11 | 0.00 | 284451.05 | 0.00 | 0.00 | 9875405.37 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.224481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.445905E+10 | 0.00 | 183031.95 | 0.00 | 0.00 | 6100714.69 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.240159E+10 | 0.00 | 183239.70 | 0.00 | 0.00 | 3720315.99 | 0.00 | 0.36 |
| February | 0.00 | 0.244583E+10 | 0.00 | 17131.04 | 0.00 | 0.00 | 430804.51 | 0.00 | 0.36 |
| March | 0.00 | 0.297182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.371508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.440199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.424350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.318064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.388212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.371285E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.355505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.307977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.256261E+10 | 0.00 | 51895.00 | 0.00 | 0.00 | 2051781.49 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.401528E+11 | 0.00 | 252265.75 | 0.00 | 0.00 | 6202901.98 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.240159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.440199E+10 | 0.00 | 183239.70 | 0.00 | 0.00 | 3720315.99 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.240193E+10 | 0.00 | 183697.96 | 0.00 | 0.00 | 3715434.37 | 0.00 | 0.36 |
| February | 0.00 | 0.244618E+10 | 0.00 | 17161.02 | 0.00 | 0.00 | 431577.65 | 0.00 | 0.36 |
| March | 0.00 | 0.297192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.371543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.440244E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.424402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.318112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.388268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.371344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.355537E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.308014E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.256291E+10 | 0.00 | 51924.32 | 0.00 | 0.00 | 2051171.88 | 0.00 | 0.36 |
| Annual Sum or Average | 0.00 | 0.401576E+11 | 0.00 | 252783.30 | 0.00 | 0.00 | 6198183.90 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.240193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 0.00 | 0.440244E+10 | 0.00 | 183697.96 | 0.00 | 0.00 | 3715434.37 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 299219.12 | 0.115821E+10 | 0.00 | 85853.76 | 0.00 | 0.00 | 7764462.25 | 0.00 | 0.36 |
| February | 0.00 | 0.119470E+10 | 0.00 | 23270.22 | 0.00 | 0.00 | 671525.60 | 0.00 | 0.36 |
| March | 0.00 | 0.145854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.187098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.220232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.213541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.159498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.192268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.186557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.175649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.151188E+10 | 0.00 | 9812.88 | 0.00 | 0.00 | 118541.53 | 0.00 | 0.36 |
| December | 1047479.08 | 0.122826E+10 | 0.00 | 43132.81 | 0.00 | 0.00 | 3970425.91 | 0.00 | 0.36 |
| Annual Sum or Average | 1346698.21 | 0.199000E+11 | 0.00 | 162069.66 | 0.00 | 0.00 | 12524955.29 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.115821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 1047479.08 | 0.220232E+10 | 0.00 | 85853.76 | 0.00 | 0.00 | 7764462.25 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 746702.65 | 0.110221E+10 | 0.00 | 76584.66 | 0.00 | 0.00 | 8719439.74 | 0.00 | 0.36 |
| February | 0.00 | 0.115426E+10 | 0.00 | 21215.92 | 0.00 | 0.00 | 847696.56 | 0.00 | 0.36 |
| March | 0.00 | 0.143877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.187320E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.222267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.217194E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.161663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.193562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.185790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.172714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.146186E+10 | 0.00 | 8990.27 | 0.00 | 0.00 | 195479.75 | 0.00 | 0.36 |
| December | 1994800.14 | 0.116396E+10 | 0.00 | 47870.00 | 0.00 | 0.00 | 4173559.98 | 0.00 | 0.36 |
| Annual Sum or Average | 2741502.79 | 0.197262E+11 | 0.00 | 154660.85 | 0.00 | 0.00 | 13936176.03 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.110221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 1994800.14 | 0.222267E+10 | 0.00 | 76584.66 | 0.00 | 0.00 | 8719439.74 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 221389.66 | 0.117331E+10 | 0.00 | 98928.66 | 0.00 | 0.00 | 7471708.90 | 0.00 | 0.36 |
| February | 0.00 | 0.120965E+10 | 0.00 | 27028.87 | 0.00 | 0.00 | 565938.07 | 0.00 | 0.36 |
| March | 0.00 | 0.147069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.188561E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.221696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.215136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.161026E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.193706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.188095E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.176951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.152531E+10 | 0.00 | 9527.71 | 0.00 | 0.00 | 78030.25 | 0.00 | 0.36 |
| December | 1500924.14 | 0.124291E+10 | 0.00 | 40140.39 | 0.00 | 0.00 | 3470957.82 | 0.00 | 0.36 |
| Annual Sum or Average | 1722313.80 | 0.200736E+11 | 0.00 | 175625.62 | 0.00 | 0.00 | 11586635.05 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.117331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 1500924.14 | 0.221696E+10 | 0.00 | 98928.66 | 0.00 | 0.00 | 7471708.90 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 571102.47 | 0.111502E+10 | 0.00 | 94647.83 | 0.00 | 0.00 | 8541899.91 | 0.00 | 0.36 |
| February | 0.00 | 0.116708E+10 | 0.00 | 25379.15 | 0.00 | 0.00 | 732580.66 | 0.00 | 0.36 |
| March | 0.00 | 0.144800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.188484E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.223428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.218480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.162883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.194733E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.187045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.173738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.147264E+10 | 0.00 | 10138.45 | 0.00 | 0.00 | 146994.40 | 0.00 | 0.36 |
| December | 1859412.53 | 0.117626E+10 | 0.00 | 49795.07 | 0.00 | 0.00 | 4165309.20 | 0.00 | 0.36 |
| Annual Sum or Average | 2430515.00 | 0.198669E+11 | 0.00 | 179960.51 | 0.00 | 0.00 | 13586784.17 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.111502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 1859412.53 | 0.223428E+10 | 0.00 | 94647.83 | 0.00 | 0.00 | 8541899.91 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 42126.56 | 0.110341E+10 | 0.00 | 80046.54 | 0.00 | 0.00 | 7592942.16 | 0.00 | 0.36 |
| February | 0.00 | 0.114998E+10 | 0.00 | 21881.77 | 0.00 | 0.00 | 763148.69 | 0.00 | 0.36 |
| March | 0.00 | 0.144552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.187077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.223433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.218184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.161597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.195125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.185338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.172865E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.145925E+10 | 0.00 | 5282.55 | 0.00 | 0.00 | 57936.80 | 0.00 | 0.36 |
| December | 734161.98 | 0.116578E+10 | 0.00 | 47849.70 | 0.00 | 0.00 | 3715316.73 | 0.00 | 0.36 |
| Annual Sum or Average | 776288.54 | 0.197601E+11 | 0.00 | 155060.55 | 0.00 | 0.00 | 12129344.38 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.110341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 734161.98 | 0.223433E+10 | 0.00 | 80046.54 | 0.00 | 0.00 | 7592942.16 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 42195.00 | 0.110375E+10 | 0.00 | 80412.96 | 0.00 | 0.00 | 7600875.60 | 0.00 | 0.36 |
| February | 0.00 | 0.115033E+10 | 0.00 | 21964.04 | 0.00 | 0.00 | 764088.48 | 0.00 | 0.36 |
| March | 0.00 | 0.144566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.187104E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.223465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.218220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.161634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.195162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.185378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.172895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.145956E+10 | 0.00 | 5330.72 | 0.00 | 0.00 | 57630.26 | 0.00 | 0.36 |
| December | 734862.88 | 0.116610E+10 | 0.00 | 47871.59 | 0.00 | 0.00 | 3721945.16 | 0.00 | 0.36 |
| Annual Sum or Average | 777057.88 | 0.197640E+11 | 0.00 | 155579.32 | 0.00 | 0.00 | 12144539.50 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.110375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 734862.88 | 0.223465E+10 | 0.00 | 80412.96 | 0.00 | 0.00 | 7600875.60 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.117222E+10 | 0.00 | 91574.45 | 0.00 | 0.00 | 6236058.60 | 0.00 | 0.36 |
| February | 0.00 | 0.120079E+10 | 0.00 | 23538.46 | 0.00 | 0.00 | 575315.19 | 0.00 | 0.36 |
| March | 0.00 | 0.147248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.187059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.221208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.213988E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.159281E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.193787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.186522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.176635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.152106E+10 | 0.00 | 4021.79 | 0.00 | 0.00 | 20735.22 | 0.00 | 0.36 |
| December | 114545.34 | 0.124392E+10 | 0.00 | 36976.62 | 0.00 | 0.00 | 3341566.65 | 0.00 | 0.36 |
| Annual Sum or Average | 114545.34 | 0.199953E+11 | 0.00 | 156111.32 | 0.00 | 0.00 | 10173675.66 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.117222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 114545.34 | 0.221208E+10 | 0.00 | 91574.45 | 0.00 | 0.00 | 6236058.60 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.117256E+10 | 0.00 | 91970.20 | 0.00 | 0.00 | 6241219.76 | 0.00 | 0.36 |
| February | 0.00 | 0.120113E+10 | 0.00 | 23609.18 | 0.00 | 0.00 | 576072.46 | 0.00 | 0.36 |
| March | 0.00 | 0.147264E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.187090E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.221246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.214029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.159322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.193828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.186565E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.176666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.152137E+10 | 0.00 | 3911.88 | 0.00 | 0.00 | 20634.80 | 0.00 | 0.36 |
| December | 114643.80 | 0.124423E+10 | 0.00 | 36857.35 | 0.00 | 0.00 | 3347068.70 | 0.00 | 0.36 |
| Annual Sum or Average | 114643.80 | 0.199994E+11 | 0.00 | 156348.61 | 0.00 | 0.00 | 10184995.71 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.117256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 114643.80 | 0.221246E+10 | 0.00 | 91970.20 | 0.00 | 0.00 | 6241219.76 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:34
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.120075E+12 | -0.838768E+10 | 0.00 | -449105807.1 | 0.204018E+12 |
| February | 0.113259E+12 | -0.965603E+10 | 0.00 | -578638326.1 | 0.198966E+12 |
| March | 0.138284E+12 | -0.170592E+11 | 0.00 | -863965968.3 | 0.238081E+12 |
| April | 0.134675E+12 | -0.180535E+11 | 0.00 | -0.112632E+10 | 0.253177E+12 |
| May | 0.143196E+12 | -0.232129E+11 | 0.00 | -0.149727E+10 | 0.283012E+12 |
| June | 0.149934E+12 | -0.222365E+11 | 0.00 | -0.145202E+10 | 0.279087E+12 |
| July | 0.125452E+12 | -0.125478E+11 | 0.00 | -807570153.3 | 0.230606E+12 |
| August | 0.151743E+12 | -0.206125E+11 | 0.00 | -0.123887E+10 | 0.253953E+12 |
| September | 0.119513E+12 | -0.138790E+11 | 0.00 | -0.107504E+10 | 0.235626E+12 |
| October | 0.137242E+12 | -0.126899E+11 | 0.00 | -963296109.1 | 0.228829E+12 |
| November | 0.115701E+12 | -0.944960E+10 | 0.00 | -765304343.9 | 0.212295E+12 |
| December | 0.114515E+12 | -0.759755E+10 | 0.00 | -451604458.4 | 0.201783E+12 |
| Annual Sum or Average | 0.156359E+13 | -0.175382E+12 | 0.00 | -0.112690E+11 | 0.281943E+13 |
| Minimum of Months | 0.113259E+12 | -0.232129E+11 | 0.00 | -0.149727E+10 | 0.198966E+12 |