Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1646.03 | 525.11 | 582.88 |
| Net Site Energy | 1646.03 | 525.11 | 582.88 |
| Total Source Energy | 5212.95 | 1663.03 | 1845.96 |
| Net Source Energy | 5212.95 | 1663.03 | 1845.96 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 526.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 181.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 330.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1646.02 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 526.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 50.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 181.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 330.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 526.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 50.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 181.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 330.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 367.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 582.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 331.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 525.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1646.020 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1646.020 | 100.00 |
| Total On-Site and Utility Electric Sources | 1646.020 | 100.00 |
| Total Electricity End Uses | 1646.020 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 40.54 |
| Air to Air Heat Recovery for Heating | 0.00 | 59.46 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.17 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8755.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY ARE_DUBAI_DUBAIINTL
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Dubai Intl AP - ARE IWEC2 WMO#=411940 |
| Latitude [deg] | 25.25 |
| Longitude [deg] | 55.33 |
| Elevation [m] | 5.00 |
| Time Zone | 4.00 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 30-JUL-17:10 | 20-JAN-06:00 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 524.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 45004.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 5231.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22609.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 11797.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 30030.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 114674.51 | 524.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 524.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 45004.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4887.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 344.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18441.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 11797.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 30030.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 1665.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 573.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1047.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 5212.95 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 589.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 56.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 203.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 371.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1845.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 531.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 183.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 334.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1663.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.433384 |
| SPLIT GNW SUPPLY FAN | 0.421796 |
| SPLIT OFFICE SUPPLY FAN | 0.493971 |
| SPLIT GNE SUPPLY FAN | 0.407695 |
| SPLIT GN1 SUPPLY FAN | 0.353501 |
| SPLIT GN2 SUPPLY FAN | 0.353194 |
| SPLIT GS1 SUPPLY FAN | 0.366030 |
| SPLIT GS2 SUPPLY FAN | 0.368508 |
| SPLIT MSW SUPPLY FAN | 0.923542 |
| SPLIT MNW SUPPLY FAN | 0.898399 |
| SPLIT MSE SUPPLY FAN | 0.888637 |
| SPLIT MNE SUPPLY FAN | 0.863608 |
| SPLIT MN1 SUPPLY FAN | 0.744960 |
| SPLIT MN2 SUPPLY FAN | 0.744242 |
| SPLIT MS1 SUPPLY FAN | 0.772270 |
| SPLIT MS2 SUPPLY FAN | 0.771542 |
| SPLIT TSW SUPPLY FAN | 0.523046 |
| SPLIT TNW SUPPLY FAN | 0.512488 |
| SPLIT TSE SUPPLY FAN | 0.495953 |
| SPLIT TNE SUPPLY FAN | 0.485387 |
| SPLIT TN1 SUPPLY FAN | 0.428144 |
| SPLIT TN2 SUPPLY FAN | 0.427179 |
| SPLIT TS1 SUPPLY FAN | 0.439325 |
| SPLIT TS2 SUPPLY FAN | 0.438367 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.433384 |
| G NW APARTMENT DIRECT AIR | 0.421796 |
| OFFICE DIRECT AIR | 0.493971 |
| G NE APARTMENT DIRECT AIR | 0.407695 |
| G N1 APARTMENT DIRECT AIR | 0.353501 |
| G N2 APARTMENT DIRECT AIR | 0.353194 |
| G S1 APARTMENT DIRECT AIR | 0.366030 |
| G S2 APARTMENT DIRECT AIR | 0.368508 |
| M SW APARTMENT DIRECT AIR | 0.923542 |
| M NW APARTMENT DIRECT AIR | 0.898399 |
| M SE APARTMENT DIRECT AIR | 0.888637 |
| M NE APARTMENT DIRECT AIR | 0.863608 |
| M N1 APARTMENT DIRECT AIR | 0.744960 |
| M N2 APARTMENT DIRECT AIR | 0.744242 |
| M S1 APARTMENT DIRECT AIR | 0.772270 |
| M S2 APARTMENT DIRECT AIR | 0.771542 |
| T SW APARTMENT DIRECT AIR | 0.523046 |
| T NW APARTMENT DIRECT AIR | 0.512488 |
| T SE APARTMENT DIRECT AIR | 0.495953 |
| T NE APARTMENT DIRECT AIR | 0.485387 |
| T N1 APARTMENT DIRECT AIR | 0.428144 |
| T N2 APARTMENT DIRECT AIR | 0.427179 |
| T S1 APARTMENT DIRECT AIR | 0.439325 |
| T S2 APARTMENT DIRECT AIR | 0.438367 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.433384 | 0.433384 | 0.433384 | 0.433384 | 0.433384 | 0.433384 | 1.00 | 1.00 | 0.433384 |
| SPLIT GNW | 0.421796 | 0.421796 | 0.421796 | 0.421796 | 0.421796 | 0.421796 | 1.00 | 1.00 | 0.421796 |
| SPLIT OFFICE | 0.493971 | 0.493971 | 0.493971 | 0.493971 | 0.493971 | 0.493971 | 1.00 | 1.00 | 0.493971 |
| SPLIT GNE | 0.407695 | 0.407695 | 0.407695 | 0.407695 | 0.407695 | 0.407695 | 1.00 | 1.00 | 0.407695 |
| SPLIT GN1 | 0.353501 | 0.353501 | 0.353501 | 0.353501 | 0.353501 | 0.353501 | 1.00 | 1.00 | 0.353501 |
| SPLIT GN2 | 0.353194 | 0.353194 | 0.353194 | 0.353194 | 0.353194 | 0.353194 | 1.00 | 1.00 | 0.353194 |
| SPLIT GS1 | 0.366030 | 0.366030 | 0.366030 | 0.366030 | 0.366030 | 0.366030 | 1.00 | 1.00 | 0.366030 |
| SPLIT GS2 | 0.368508 | 0.368508 | 0.368508 | 0.368508 | 0.368508 | 0.368508 | 1.00 | 1.00 | 0.368508 |
| SPLIT MSW | 0.923542 | 0.923542 | 0.923542 | 0.923542 | 0.923542 | 0.923542 | 1.00 | 1.00 | 0.923542 |
| SPLIT MNW | 0.898399 | 0.898399 | 0.898399 | 0.898399 | 0.898399 | 0.898399 | 1.00 | 1.00 | 0.898399 |
| SPLIT MSE | 0.888637 | 0.888637 | 0.888637 | 0.888637 | 0.888637 | 0.888637 | 1.00 | 1.00 | 0.888637 |
| SPLIT MNE | 0.863608 | 0.863608 | 0.863608 | 0.863608 | 0.863608 | 0.863608 | 1.00 | 1.00 | 0.863608 |
| SPLIT MN1 | 0.744960 | 0.744960 | 0.744960 | 0.744960 | 0.744960 | 0.744960 | 1.00 | 1.00 | 0.744960 |
| SPLIT MN2 | 0.744242 | 0.744242 | 0.744242 | 0.744242 | 0.744242 | 0.744242 | 1.00 | 1.00 | 0.744242 |
| SPLIT MS1 | 0.772270 | 0.772270 | 0.772270 | 0.772270 | 0.772270 | 0.772270 | 1.00 | 1.00 | 0.772270 |
| SPLIT MS2 | 0.771542 | 0.771542 | 0.771542 | 0.771542 | 0.771542 | 0.771542 | 1.00 | 1.00 | 0.771542 |
| SPLIT TSW | 0.523046 | 0.523046 | 0.523046 | 0.523046 | 0.523046 | 0.523046 | 1.00 | 1.00 | 0.523046 |
| SPLIT TNW | 0.512488 | 0.512488 | 0.512488 | 0.512488 | 0.512488 | 0.512488 | 1.00 | 1.00 | 0.512488 |
| SPLIT TSE | 0.495953 | 0.495953 | 0.495953 | 0.495953 | 0.495953 | 0.495953 | 1.00 | 1.00 | 0.495953 |
| SPLIT TNE | 0.485387 | 0.485387 | 0.485387 | 0.485387 | 0.485387 | 0.485387 | 1.00 | 1.00 | 0.485387 |
| SPLIT TN1 | 0.428144 | 0.428144 | 0.428144 | 0.428144 | 0.428144 | 0.428144 | 1.00 | 1.00 | 0.428144 |
| SPLIT TN2 | 0.427179 | 0.427179 | 0.427179 | 0.427179 | 0.427179 | 0.427179 | 1.00 | 1.00 | 0.427179 |
| SPLIT TS1 | 0.439325 | 0.439325 | 0.439325 | 0.439325 | 0.439325 | 0.439325 | 1.00 | 1.00 | 0.439325 |
| SPLIT TS2 | 0.438367 | 0.438367 | 0.438367 | 0.438367 | 0.438367 | 0.438367 | 1.00 | 1.00 | 0.438367 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.433384 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.421796 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.493971 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.407695 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.353501 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.353194 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.366030 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.368508 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.923542 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.898399 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.888637 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.863608 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.744960 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.744242 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.772270 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.771542 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.523046 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.512488 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.495953 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.485387 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.428144 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.427179 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.439325 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.438367 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.433384 | 0.433384 | 0.433384 | 0.433384 | 8052.14 | 10170.18 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.421796 | 0.421796 | 0.421796 | 0.421796 | 7845.94 | 9905.30 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.493971 | 0.493971 | 0.493971 | 0.493971 | 8997.02 | 11678.50 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.407695 | 0.407695 | 0.407695 | 0.407695 | 7611.53 | 9582.96 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.353501 | 0.353501 | 0.353501 | 0.353501 | 6661.56 | 8344.18 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.353194 | 0.353194 | 0.353194 | 0.353194 | 6656.47 | 8337.14 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.366030 | 0.366030 | 0.366030 | 0.366030 | 6888.96 | 8630.56 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.368508 | 0.368508 | 0.368508 | 0.368508 | 6930.02 | 8687.20 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.923542 | 0.923542 | 0.923542 | 0.923542 | 17164.15 | 21637.91 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.898399 | 0.898399 | 0.898399 | 0.898399 | 16720.99 | 21063.17 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.888637 | 0.888637 | 0.888637 | 0.888637 | 16582.88 | 20840.04 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.863608 | 0.863608 | 0.863608 | 0.863608 | 16140.77 | 20267.90 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.744960 | 0.744960 | 0.744960 | 0.744960 | 14028.34 | 17556.01 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.744242 | 0.744242 | 0.744242 | 0.744242 | 14016.45 | 17539.60 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.772270 | 0.772270 | 0.772270 | 0.772270 | 14516.11 | 18180.27 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.771542 | 0.771542 | 0.771542 | 0.771542 | 14504.09 | 18163.62 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.523046 | 0.523046 | 0.523046 | 0.523046 | 9666.59 | 12219.53 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.512488 | 0.512488 | 0.512488 | 0.512488 | 9479.91 | 11978.03 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.495953 | 0.495953 | 0.495953 | 0.495953 | 9213.50 | 11600.25 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.485387 | 0.485387 | 0.485387 | 0.485387 | 9026.36 | 11358.56 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.428144 | 0.428144 | 0.428144 | 0.428144 | 7976.92 | 10050.17 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.427179 | 0.427179 | 0.427179 | 0.427179 | 7960.80 | 10028.11 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.439325 | 0.439325 | 0.439325 | 0.439325 | 8176.40 | 10305.88 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.438367 | 0.438367 | 0.438367 | 0.438367 | 8160.41 | 10283.97 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.433384 | 8052.14 | 0.800562 |
| SPLIT GNW COOLING COIL | 0.421796 | 7845.94 | 0.800182 |
| SPLIT OFFICE COOLING COIL | 0.493971 | 8997.02 | 0.800145 |
| SPLIT GNE COOLING COIL | 0.407695 | 7611.53 | 0.800983 |
| SPLIT GN1 COOLING COIL | 0.353501 | 6661.56 | 0.800959 |
| SPLIT GN2 COOLING COIL | 0.353194 | 6656.47 | 0.800924 |
| SPLIT GS1 COOLING COIL | 0.366030 | 6888.96 | 0.800366 |
| SPLIT GS2 COOLING COIL | 0.368508 | 6930.02 | 0.800626 |
| SPLIT MSW COOLING COIL | 0.923542 | 17164.15 | 0.800466 |
| SPLIT MNW COOLING COIL | 0.898399 | 16720.99 | 0.800994 |
| SPLIT MSE COOLING COIL | 0.888637 | 16582.88 | 0.800134 |
| SPLIT MNE COOLING COIL | 0.863608 | 16140.77 | 0.800630 |
| SPLIT MN1 COOLING COIL | 0.744960 | 14028.34 | 0.800191 |
| SPLIT MN2 COOLING COIL | 0.744242 | 14016.45 | 0.800153 |
| SPLIT MS1 COOLING COIL | 0.772270 | 14516.11 | 0.800781 |
| SPLIT MS2 COOLING COIL | 0.771542 | 14504.09 | 0.800743 |
| SPLIT TSW COOLING COIL | 0.523046 | 9666.59 | 0.800305 |
| SPLIT TNW COOLING COIL | 0.512488 | 9479.91 | 0.800011 |
| SPLIT TSE COOLING COIL | 0.495953 | 9213.50 | 0.800603 |
| SPLIT TNE COOLING COIL | 0.485387 | 9026.36 | 0.800271 |
| SPLIT TN1 COOLING COIL | 0.428144 | 7976.92 | 0.800653 |
| SPLIT TN2 COOLING COIL | 0.427179 | 7960.80 | 0.800577 |
| SPLIT TS1 COOLING COIL | 0.439325 | 8176.40 | 0.800006 |
| SPLIT TS2 COOLING COIL | 0.438367 | 8160.41 | 0.800932 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 10170.18 |
| SPLIT GNW HEATING COIL | 9905.30 |
| SPLIT OFFICE HEATING COIL | 11678.50 |
| SPLIT GNE HEATING COIL | 9582.96 |
| SPLIT GN1 HEATING COIL | 8344.18 |
| SPLIT GN2 HEATING COIL | 8337.14 |
| SPLIT GS1 HEATING COIL | 8630.56 |
| SPLIT GS2 HEATING COIL | 8687.20 |
| SPLIT MSW HEATING COIL | 21637.91 |
| SPLIT MNW HEATING COIL | 21063.17 |
| SPLIT MSE HEATING COIL | 20840.04 |
| SPLIT MNE HEATING COIL | 20267.90 |
| SPLIT MN1 HEATING COIL | 17556.01 |
| SPLIT MN2 HEATING COIL | 17539.60 |
| SPLIT MS1 HEATING COIL | 18180.27 |
| SPLIT MS2 HEATING COIL | 18163.62 |
| SPLIT TSW HEATING COIL | 12219.53 |
| SPLIT TNW HEATING COIL | 11978.03 |
| SPLIT TSE HEATING COIL | 11600.25 |
| SPLIT TNE HEATING COIL | 11358.56 |
| SPLIT TN1 HEATING COIL | 10050.17 |
| SPLIT TN2 HEATING COIL | 10028.11 |
| SPLIT TS1 HEATING COIL | 10305.88 |
| SPLIT TS2 HEATING COIL | 10283.97 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 29.50 | 25.50 | 21.10 | 19.20 | 20.80 | 23.10 | 26.50 | 31.40 | 33.00 | 35.10 | 35.30 | 32.50 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Dubai Intl AP - ARE IWEC2 WMO#=411940 | 25.25 | 55.33 | 4.00 | 5.00 | 101265 | 1.2036 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 27.75 | 16.10 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.192E-004 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 5087.38547 | 6104.86256 | 0.36115 | 0.43338 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 3 | G NW APARTMENT | Cooling | 4953.77906 | 5944.53487 | 0.35150 | 0.42180 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 5 | OFFICE | Cooling | 5719.31415 | 6863.17697 | 0.41164 | 0.49397 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 37.46500 | 1.07727E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 383.60059 | 460.32071 | 1.65372E-002 | 3.81060E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 12.70000 | 9.15345E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 4791.15109 | 5749.38131 | 0.33975 | 0.40769 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 9 | G N1 APARTMENT | Cooling | 4168.56989 | 5002.28386 | 0.29458 | 0.35350 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 11 | G N2 APARTMENT | Cooling | 4165.04227 | 4998.05073 | 0.29433 | 0.35319 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 13 | G S1 APARTMENT | Cooling | 4312.22110 | 5174.66532 | 0.30502 | 0.36603 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 15 | G S2 APARTMENT | Cooling | 4340.61157 | 5208.73389 | 0.30709 | 0.36851 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 17 | M SW APARTMENT | Cooling | 10832.95131 | 12999.54157 | 0.76962 | 0.92354 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 469.72531 | 563.67037 | 2.02502E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 10542.07031 | 12650.48437 | 0.74867 | 0.89840 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 145.00344 | 174.00413 | 6.25121E-003 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 10428.56340 | 12514.27609 | 0.74053 | 0.88864 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 466.18346 | 559.42016 | 2.00975E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 10139.41898 | 12167.30278 | 0.71967 | 0.86361 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 140.33719 | 168.40463 | 6.05004E-003 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 8772.91280 | 10527.49536 | 0.62080 | 0.74496 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 27 | M N2 APARTMENT | Cooling | 8764.65625 | 10517.58750 | 0.62020 | 0.74424 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 29 | M S1 APARTMENT | Cooling | 9086.93089 | 10904.31707 | 0.64356 | 0.77227 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 31 | M S2 APARTMENT | Cooling | 9078.54152 | 10894.24983 | 0.64295 | 0.77154 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 33 | T SW APARTMENT | Cooling | 6124.09652 | 7348.91582 | 0.43587 | 0.52305 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 795.50821 | 954.60985 | 3.42951E-002 | 4.11541E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 6002.60323 | 7203.12387 | 0.42707 | 0.51249 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 656.67954 | 788.01545 | 2.83105E-002 | 3.39725E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 5812.22574 | 6974.67089 | 0.41329 | 0.49595 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 792.94886 | 951.53863 | 3.41848E-002 | 4.10217E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 5690.72224 | 6828.86669 | 0.40449 | 0.48539 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 654.27404 | 785.12885 | 2.82067E-002 | 3.38481E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 5031.03773 | 6037.24527 | 0.35679 | 0.42814 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 380.64860 | 456.77832 | 1.64103E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 5019.85977 | 6023.83173 | 0.35598 | 0.42718 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 380.55189 | 456.66226 | 1.64061E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 5160.56287 | 6192.67544 | 0.36610 | 0.43933 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 520.24305 | 624.29166 | 2.24280E-002 | 2.69136E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 5149.45113 | 6179.34136 | 0.36531 | 0.43837 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 39.01700 | 1.07753E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 520.14364 | 624.17237 | 2.24238E-002 | 2.69085E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12.70000 | 9.15345E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 6368.06 | 0.43338 | 0.43338 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 6209.64 | 0.42180 | 0.42180 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 7291.82 | 0.49397 | 0.49397 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 1258.18 | 3.81060E-002 | 3.81060E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 6016.71 | 0.40769 | 0.40769 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 5276.61 | 0.35350 | 0.35350 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 5272.41 | 0.35319 | 0.35319 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 5447.60 | 0.36603 | 0.36603 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 5481.32 | 0.36851 | 0.36851 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 13514.36 | 0.92354 | 0.92354 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 13170.20 | 0.89840 | 0.89840 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 13036.08 | 0.88864 | 0.88864 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 12693.65 | 0.86361 | 0.86361 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 11072.05 | 0.74496 | 0.74496 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 11062.23 | 0.74424 | 0.74424 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 11445.14 | 0.77227 | 0.77227 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 11435.18 | 0.77154 | 0.77154 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 1713.92 | 5.19091E-002 | 5.19091E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 7595.23 | 0.52305 | 0.52305 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 1204.39 | 4.11541E-002 | 4.11541E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 7451.13 | 0.51249 | 0.51249 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 1040.24 | 3.39725E-002 | 3.39725E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 7225.35 | 0.49595 | 0.49595 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 1201.37 | 4.10217E-002 | 4.10217E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 7081.17 | 0.48539 | 0.48539 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 1037.39 | 3.38481E-002 | 3.38481E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 6299.27 | 0.42814 | 0.42814 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 6286.05 | 0.42718 | 0.42718 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 856.96 | 2.59546E-002 | 2.59546E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 6452.36 | 0.43933 | 0.43933 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 878.89 | 2.69136E-002 | 2.69136E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 6439.23 | 0.43837 | 0.43837 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 878.77 | 2.69085E-002 | 2.69085E-002 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.43338 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42180 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.49397 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.40769 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35350 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35319 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36603 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36851 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.92354 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.89840 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.88864 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.86361 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.74496 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.74424 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.77227 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.77154 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.52305 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.51249 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.49595 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.48539 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42814 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42718 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.43933 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.43837 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.43338 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.43338 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.43338 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.43338 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.43338 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.43338 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42180 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42180 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42180 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42180 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42180 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.42180 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.49397 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.49397 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.49397 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.49397 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.49397 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.49397 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.40769 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.40769 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.40769 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.40769 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.40769 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.40769 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35350 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35350 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35350 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35350 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35350 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35350 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35319 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35319 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35319 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35319 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35319 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35319 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36603 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36603 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36603 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36603 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36603 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36603 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36851 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36851 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36851 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36851 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36851 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36851 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.92354 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.92354 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.92354 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.92354 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92354 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.92354 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.89840 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.89840 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.89840 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.89840 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.89840 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.89840 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.88864 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.88864 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.88864 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.88864 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.88864 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.88864 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.86361 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.86361 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.86361 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.86361 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.86361 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.86361 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.74496 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.74496 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.74496 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.74496 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.74496 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.74496 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.74424 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.74424 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.74424 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.74424 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.74424 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.74424 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.77227 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.77227 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.77227 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.77227 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.77227 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.77227 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.77154 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.77154 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.77154 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.77154 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.77154 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.77154 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.52305 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.52305 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.52305 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.52305 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.52305 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.52305 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.51249 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.51249 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.51249 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.51249 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.51249 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.51249 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.49595 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.49595 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.49595 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.49595 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.49595 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.49595 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.48539 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.48539 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.48539 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.48539 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.48539 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.48539 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42814 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42814 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42814 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42814 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42814 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.42814 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42718 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42718 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42718 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42718 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42718 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.42718 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.43933 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.43933 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.43933 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.43933 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.43933 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.43933 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.43837 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.43837 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.43837 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.43837 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.43837 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.43837 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.43338 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.42180 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.49397 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.40769 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.35350 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.35319 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.36603 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.36851 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.92354 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.89840 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.88864 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.86361 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.74496 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.74424 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.77227 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.77154 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.52305 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.51249 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.49595 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.48539 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.42814 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.42718 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.43933 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.43837 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.43338 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.43338 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.43338 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.43338 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.43338 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8052.13731 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10170.18134 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.43338 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.43338 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8052.13731 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80056 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 10170.18134 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42180 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42180 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42180 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42180 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42180 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7845.93600 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9905.29992 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42180 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42180 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7845.93600 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80018 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 9905.29992 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.49397 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.49397 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.49397 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.49397 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.49397 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8997.01961 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11678.49707 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.49397 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.49397 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8997.01961 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80014 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 11678.49707 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.40769 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.40769 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.40769 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.40769 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.40769 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7611.52595 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9582.95764 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.40769 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.40769 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7611.52595 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80098 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 9582.95764 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35350 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35350 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35350 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35350 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35350 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6661.56089 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8344.17742 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35350 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35350 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6661.56089 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80096 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 8344.17742 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35319 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35319 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35319 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35319 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35319 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6656.47325 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8337.14461 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35319 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35319 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6656.47325 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80092 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 8337.14461 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36603 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36603 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36603 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36603 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36603 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6888.95815 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8630.56318 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36603 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36603 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6888.95815 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80037 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 8630.56318 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36851 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36851 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36851 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36851 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36851 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6930.01678 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8687.19908 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36851 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36851 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6930.01678 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80063 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 8687.19908 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92354 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92354 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92354 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92354 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92354 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 17164.14626 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 21637.91136 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.92354 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.92354 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 17164.14626 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80047 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 21637.91136 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.89840 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.89840 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.89840 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.89840 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.89840 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 16720.98969 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 21063.17129 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.89840 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.89840 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 16720.98969 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80099 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 21063.17129 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.88864 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.88864 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.88864 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.88864 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.88864 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 16582.88447 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20840.04482 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.88864 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.88864 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 16582.88447 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80013 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 20840.04482 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.86361 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.86361 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.86361 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.86361 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.86361 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 16140.76566 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20267.90289 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.86361 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.86361 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 16140.76566 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80063 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 20267.90289 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.74496 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.74496 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.74496 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.74496 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.74496 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14028.34186 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17556.01142 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.74496 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.74496 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14028.34186 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80019 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 17556.01142 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.74424 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.74424 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.74424 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.74424 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.74424 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14016.45040 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17539.59848 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.74424 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.74424 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14016.45040 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80015 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 17539.59848 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.77227 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.77227 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.77227 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.77227 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.77227 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14516.10897 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18180.27047 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.77227 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77227 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14516.10897 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80078 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 18180.27047 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.77154 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.77154 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.77154 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.77154 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.77154 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14504.09488 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18163.61809 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.77154 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77154 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14504.09488 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80074 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 18163.61809 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.52305 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.52305 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.52305 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.52305 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.52305 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9666.59473 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 12219.52952 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.52305 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.52305 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9666.59473 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80030 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 12219.52952 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.51249 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.51249 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.51249 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.51249 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.51249 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9479.91442 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11978.03375 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.51249 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.51249 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9479.91442 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80001 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 11978.03375 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.49595 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.49595 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.49595 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.49595 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.49595 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9213.49522 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11600.24933 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.49595 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.49595 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9213.49522 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80060 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 11600.24933 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.48539 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.48539 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.48539 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.48539 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.48539 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9026.35959 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11358.56213 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.48539 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.48539 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9026.35959 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80027 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 11358.56213 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42814 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42814 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42814 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42814 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42814 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7976.92014 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10050.16965 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42814 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42814 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7976.92014 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80065 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 10050.16965 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42718 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42718 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42718 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42718 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42718 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7960.80197 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10028.11085 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42718 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42718 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7960.80197 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80058 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 10028.11085 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.43933 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.43933 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.43933 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.43933 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.43933 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8176.39925 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10305.88226 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.43933 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.43933 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8176.39925 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80001 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 10305.88226 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.43837 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.43837 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.43837 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.43837 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.43837 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8160.41462 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10283.97395 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.43837 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.43837 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8160.41462 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80093 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 10283.97395 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 7711.9 | 3.20 | 10.91 | 11.35 | 10.74 | 10.72 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 7514.8 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 8609.4 | 3.19 | 10.87 | 11.31 | 10.69 | 10.67 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 7291.5 | 3.20 | 10.92 | 11.36 | 10.74 | 10.74 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 6384.0 | 3.21 | 10.94 | 11.38 | 10.76 | 10.77 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 6379.2 | 3.21 | 10.94 | 11.38 | 10.76 | 10.77 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 6601.6 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 6640.7 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 16439.2 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 16015.8 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 15885.3 | 3.20 | 10.92 | 11.36 | 10.74 | 10.74 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 15462.8 | 3.20 | 10.92 | 11.36 | 10.75 | 10.74 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 13443.5 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 13432.1 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 13909.8 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 13898.4 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 9256.1 | 3.19 | 10.90 | 11.34 | 10.72 | 10.71 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 9077.7 | 3.19 | 10.90 | 11.34 | 10.73 | 10.71 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 8824.2 | 3.20 | 10.91 | 11.35 | 10.73 | 10.72 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 8645.3 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 7640.8 | 3.20 | 10.92 | 11.35 | 10.74 | 10.73 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 7625.5 | 3.20 | 10.92 | 11.36 | 10.74 | 10.73 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 7831.5 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 7816.3 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.200 | 1.017 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.200 | 1.017 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.200 | 1.017 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.854 | 0.757 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.854 | 0.757 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 6.3625905840E-003 | 1.8870489134E-002 | Pass | Pass | 3.5786209728E-002 | 5.7203221367E-002 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1512038777E-002 | 2.5067454087E-002 | Pass | Pass | 3.3169492707E-002 | 4.7707178841E-002 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 3.0743133170E-002 | 2.1388491176E-002 | Pass | Pass | 0.1154582190 | 0.2487442743 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1998967305E-002 | 2.5445334874E-002 | Pass | Pass | 3.3578335391E-002 | 5.1225253200E-002 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.4006629333E-003 | 2.0441652716E-002 | Pass | Pass | 3.1436113982E-002 | 5.6112964383E-002 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.5407011254E-003 | 2.0554907125E-002 | Pass | Pass | 3.1296724983E-002 | 5.5721582674E-002 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 7.9010724509E-004 | 5.3669329072E-003 | Pass | Pass | 3.4886241765E-002 | 0.1036271077 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7254401642E-004 | 2.0105386529E-003 | Pass | Pass | 3.4537745584E-002 | 0.1190789745 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.2573187646E-002 | 2.6381251871E-002 | Pass | Pass | 3.6699656909E-002 | 4.5539214062E-002 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6258822255E-002 | 2.6353705773E-002 | Pass | Pass | 4.2223657512E-002 | 6.3136037288E-002 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.2820346216E-002 | 2.6863169968E-002 | Pass | Pass | 3.6684270697E-002 | 4.6442753603E-002 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.7430339775E-002 | 2.7091669993E-002 | Pass | Pass | 4.2051162455E-002 | 7.0158686969E-002 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0012362280E-002 | 2.6539919380E-002 | Pass | Pass | 3.1814605115E-002 | 4.5813431806E-002 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0108572956E-002 | 2.6533030341E-002 | Pass | Pass | 3.2189081938E-002 | 4.5834316134E-002 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.5195199442E-003 | 1.3797008251E-002 | Pass | Pass | 3.7196422156E-002 | 8.4350719023E-002 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.5747015576E-003 | 1.3833523228E-002 | Pass | Pass | 3.7564558085E-002 | 8.4183264428E-002 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5873038143E-002 | 4.7612398207E-002 | Pass | Pass | 4.3949070107E-002 | 7.6313069846E-002 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.4345304783E-002 | 4.3188780079E-002 | Pass | Pass | 0.1057036203 | 0.3628964140 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5656612723E-002 | 4.6460132407E-002 | Pass | Pass | 4.2451018029E-002 | 6.6332113213E-002 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5321951468E-002 | 4.2188408807E-002 | Pass | Pass | 8.2589347451E-002 | 0.1174659576 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.1566500766E-002 | 3.8530910371E-002 | Pass | Pass | 5.1619841328E-002 | 8.5154325349E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.1794715453E-002 | 3.8467773922E-002 | Pass | Pass | 5.2583695532E-002 | 8.4071585394E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.6537853002E-002 | 4.2561389276E-002 | Pass | Pass | 4.3371297754E-002 | 6.5140410543E-002 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.6734733098E-002 | 4.2622348591E-002 | Pass | Pass | 4.4303079690E-002 | 6.9398697343E-002 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 3.3767783459E-002 | 2.1477069570E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.1150026277 | 0.3377500181 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 6.4845042380E-003 | 4.5221943681E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1000.50 | -140.0 | 0.00 | -7.5 | 2453.89 | 3306.88 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 12.70 | 0.00 | 12.70 | Wetbulb [C] | 2.00 | 170.00 |
| DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 42.80 | 9.70 | 23.80 | Wetbulb [C] | 5.00 | 80.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 2.40 | 26 | |||
| Feb | 9.60 | 38 | |||
| Mar | 3.60 | 37 | |||
| Apr | 0.00 | 0 | |||
| May | 0.00 | 0 | |||
| Jun | 0.00 | 0 | |||
| Jul | 1.20 | 13 | |||
| Aug | 0.00 | 0 | |||
| Sep | 0.00 | 0 | |||
| Oct | 0.00 | 0 | |||
| Nov | 0.00 | 0 | |||
| Dec | 18.00 | 37 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.5369_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 3.053 | 0.251 | 0.251 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.5369_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 3.053 | 0.251 | 0.251 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.5369_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 3.053 | 0.251 | 0.251 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 3.053 | 0.251 | 0.251 | |||||||||||||||||
| North Total or Average | 112.97 | 3.053 | 0.251 | 0.251 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 3.053 | 0.251 | 0.251 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.85 | 83.85 | 50.10 | |
| Exterior Lighting Total | 3183.33 | 50.10 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8052.14 | 6446.24 | 1605.90 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7845.94 | 6278.18 | 1567.76 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8997.02 | 7198.92 | 1798.10 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7611.53 | 6096.70 | 1514.82 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6661.56 | 5335.63 | 1325.93 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6656.47 | 5331.33 | 1325.14 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6888.96 | 5513.69 | 1375.27 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6930.02 | 5548.36 | 1381.66 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 17164.15 | 13739.32 | 3424.83 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 16720.99 | 13393.41 | 3327.58 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 16582.88 | 13268.53 | 3314.35 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 16140.77 | 12922.78 | 3217.99 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14028.34 | 11225.35 | 2802.99 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14016.45 | 11215.31 | 2801.15 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14516.11 | 11624.22 | 2891.89 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14504.09 | 11614.05 | 2890.04 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9666.59 | 7736.22 | 1930.37 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9479.91 | 7584.04 | 1895.87 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9213.50 | 7376.36 | 1837.14 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9026.36 | 7223.53 | 1802.83 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7976.92 | 6386.75 | 1590.17 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7960.80 | 6373.23 | 1587.57 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8176.40 | 6541.17 | 1635.23 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8160.41 | 6535.94 | 1624.48 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 7711.9 | 3.20 | 10.91 | 11.35 | 10.74 | 10.72 | |
| SPLIT GNW COOLING COIL | 7514.8 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT OFFICE COOLING COIL | 8609.4 | 3.19 | 10.87 | 11.31 | 10.69 | 10.67 | |
| SPLIT GNE COOLING COIL | 7291.5 | 3.20 | 10.92 | 11.36 | 10.74 | 10.74 | |
| SPLIT GN1 COOLING COIL | 6384.0 | 3.21 | 10.94 | 11.38 | 10.76 | 10.77 | |
| SPLIT GN2 COOLING COIL | 6379.2 | 3.21 | 10.94 | 11.38 | 10.76 | 10.77 | |
| SPLIT GS1 COOLING COIL | 6601.6 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 | |
| SPLIT GS2 COOLING COIL | 6640.7 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 | |
| SPLIT MSW COOLING COIL | 16439.2 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT MNW COOLING COIL | 16015.8 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT MSE COOLING COIL | 15885.3 | 3.20 | 10.92 | 11.36 | 10.74 | 10.74 | |
| SPLIT MNE COOLING COIL | 15462.8 | 3.20 | 10.92 | 11.36 | 10.75 | 10.74 | |
| SPLIT MN1 COOLING COIL | 13443.5 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 | |
| SPLIT MN2 COOLING COIL | 13432.1 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 | |
| SPLIT MS1 COOLING COIL | 13909.8 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 | |
| SPLIT MS2 COOLING COIL | 13898.4 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 | |
| SPLIT TSW COOLING COIL | 9256.1 | 3.19 | 10.90 | 11.34 | 10.72 | 10.71 | |
| SPLIT TNW COOLING COIL | 9077.7 | 3.19 | 10.90 | 11.34 | 10.73 | 10.71 | |
| SPLIT TSE COOLING COIL | 8824.2 | 3.20 | 10.91 | 11.35 | 10.73 | 10.72 | |
| SPLIT TNE COOLING COIL | 8645.3 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT TN1 COOLING COIL | 7640.8 | 3.20 | 10.92 | 11.35 | 10.74 | 10.73 | |
| SPLIT TN2 COOLING COIL | 7625.5 | 3.20 | 10.92 | 11.36 | 10.74 | 10.73 | |
| SPLIT TS1 COOLING COIL | 7831.5 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT TS2 COOLING COIL | 7816.3 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 10170.18 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 9905.30 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 11678.50 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 9582.96 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 8344.18 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 8337.14 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 8630.56 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 8687.20 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 21637.91 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 21063.17 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 20840.04 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 20267.90 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 17556.01 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 17539.60 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 18180.27 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 18163.62 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 12219.53 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 11978.03 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 11600.25 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 11358.56 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 10050.17 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 10028.11 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 10305.88 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 10283.97 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 485.44 | 1120.11 | 1.00 | 1.67 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 472.46 | 1120.11 | 1.00 | 1.69 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.49 | 553.30 | 1120.11 | 1.00 | 1.61 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 456.66 | 1120.11 | 1.00 | 1.71 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 395.96 | 1120.11 | 1.00 | 1.79 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 395.61 | 1120.11 | 1.00 | 1.79 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 409.99 | 1120.11 | 1.00 | 1.77 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 412.77 | 1120.11 | 1.00 | 1.76 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.92 | 1034.47 | 1120.11 | 1.00 | 1.39 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.90 | 1006.30 | 1120.11 | 1.00 | 1.40 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.89 | 995.37 | 1120.11 | 1.00 | 1.40 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.86 | 967.33 | 1120.11 | 1.00 | 1.41 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.74 | 834.44 | 1120.11 | 1.00 | 1.46 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.74 | 833.63 | 1120.11 | 1.00 | 1.46 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.77 | 865.03 | 1120.11 | 1.00 | 1.44 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.77 | 864.21 | 1120.11 | 1.00 | 1.44 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.52 | 585.87 | 1120.11 | 1.00 | 1.59 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.51 | 574.04 | 1120.11 | 1.00 | 1.59 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.50 | 555.52 | 1120.11 | 1.00 | 1.61 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.49 | 543.69 | 1120.11 | 1.00 | 1.62 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 479.57 | 1120.11 | 1.00 | 1.68 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 478.49 | 1120.11 | 1.00 | 1.68 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.44 | 492.09 | 1120.11 | 1.00 | 1.67 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.44 | 491.02 | 1120.11 | 1.00 | 1.67 | General | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 5087.39 | 6104.86 | 69.18 | 0.361 | 0.433 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00819 | 39.02 | 0.01078 | 0.026 | 0.00 |
| G NW APARTMENT | 4953.78 | 5944.53 | 67.36 | 0.351 | 0.422 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00818 | 39.02 | 0.01078 | 0.026 | 0.00 |
| OFFICE | 5719.31 | 6863.18 | 77.77 | 0.412 | 0.494 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.90 | 23.90 | 0.00811 | 37.46 | 0.01077 | 0.038 | 0.00 |
| G NE APARTMENT | 4791.15 | 5749.38 | 65.15 | 0.340 | 0.408 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00819 | 39.02 | 0.01078 | 0.026 | 0.00 |
| G N1 APARTMENT | 4168.57 | 5002.28 | 56.68 | 0.295 | 0.354 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00817 | 39.02 | 0.01078 | 0.026 | 0.00 |
| G N2 APARTMENT | 4165.04 | 4998.05 | 56.64 | 0.294 | 0.353 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00817 | 39.02 | 0.01078 | 0.026 | 0.00 |
| G S1 APARTMENT | 4312.22 | 5174.67 | 58.64 | 0.305 | 0.366 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00819 | 39.02 | 0.01078 | 0.026 | 0.00 |
| G S2 APARTMENT | 4340.61 | 5208.73 | 59.02 | 0.307 | 0.369 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00818 | 39.02 | 0.01078 | 0.026 | 0.00 |
| M SW APARTMENT | 10832.95 | 12999.54 | 147.30 | 0.770 | 0.924 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M NW APARTMENT | 10542.07 | 12650.48 | 143.35 | 0.749 | 0.898 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M SE APARTMENT | 10428.56 | 12514.28 | 141.81 | 0.741 | 0.889 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M NE APARTMENT | 10139.42 | 12167.30 | 137.87 | 0.720 | 0.864 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M N1 APARTMENT | 8772.91 | 10527.50 | 119.29 | 0.621 | 0.745 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00820 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M N2 APARTMENT | 8764.66 | 10517.59 | 119.18 | 0.620 | 0.744 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00820 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M S1 APARTMENT | 9086.93 | 10904.32 | 123.56 | 0.644 | 0.772 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 39.02 | 0.01078 | 0.052 | 0.00 |
| M S2 APARTMENT | 9078.54 | 10894.25 | 123.45 | 0.643 | 0.772 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 39.02 | 0.01078 | 0.052 | 0.00 |
| T SW APARTMENT | 6124.10 | 7348.92 | 83.27 | 0.436 | 0.523 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T NW APARTMENT | 6002.60 | 7203.12 | 81.62 | 0.427 | 0.512 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T SE APARTMENT | 5812.23 | 6974.67 | 79.03 | 0.413 | 0.496 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T NE APARTMENT | 5690.72 | 6828.87 | 77.38 | 0.404 | 0.485 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T N1 APARTMENT | 5031.04 | 6037.25 | 68.41 | 0.357 | 0.428 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00820 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T N2 APARTMENT | 5019.86 | 6023.83 | 68.26 | 0.356 | 0.427 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00820 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T S1 APARTMENT | 5160.56 | 6192.68 | 70.17 | 0.366 | 0.439 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 39.02 | 0.01078 | 0.026 | 0.00 |
| T S2 APARTMENT | 5149.45 | 6179.34 | 70.02 | 0.365 | 0.438 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 39.02 | 0.01078 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 21.40 | 0.00915 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.01 | 0.01093 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| OFFICE | 383.60 | 460.32 | 5.22 | 0.017 | 0.038 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00834 | 12.70 | 0.00915 | 0.038 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.02 | 0.01093 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.08 | 0.01260 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.08 | 0.01260 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.38 | 0.00915 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.26 | 0.00915 | 12.70 | 0.00915 | 0.026 | 0.00 | |
| M SW APARTMENT | 469.73 | 563.67 | 6.39 | 0.020 | 0.052 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00864 | 12.70 | 0.00915 | 0.052 | 0.00 |
| M NW APARTMENT | 145.00 | 174.00 | 1.97 | 0.006 | 0.052 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.01012 | 12.70 | 0.00915 | 0.052 | 0.00 |
| M SE APARTMENT | 466.18 | 559.42 | 6.34 | 0.020 | 0.052 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00864 | 12.70 | 0.00915 | 0.052 | 0.00 |
| M NE APARTMENT | 140.34 | 168.40 | 1.91 | 0.006 | 0.052 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.01014 | 12.70 | 0.00915 | 0.052 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 22.54 | 0.01138 | 12.70 | 0.00915 | 0.052 | 0.00 | |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 22.55 | 0.01138 | 12.70 | 0.00915 | 0.052 | 0.00 | |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 21.80 | 0.00915 | 12.70 | 0.00915 | 0.052 | 0.00 | |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 21.80 | 0.00915 | 12.70 | 0.00915 | 0.052 | 0.00 | |
| T SW APARTMENT | 795.51 | 954.61 | 10.82 | 0.034 | 0.041 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00831 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T NW APARTMENT | 656.68 | 788.02 | 8.93 | 0.028 | 0.034 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00870 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T SE APARTMENT | 792.95 | 951.54 | 10.78 | 0.034 | 0.041 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00831 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T NE APARTMENT | 654.27 | 785.13 | 8.90 | 0.028 | 0.034 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00871 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T N1 APARTMENT | 380.65 | 456.78 | 5.18 | 0.016 | 0.026 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00899 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T N2 APARTMENT | 380.55 | 456.66 | 5.17 | 0.016 | 0.026 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00899 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T S1 APARTMENT | 520.24 | 624.29 | 7.07 | 0.022 | 0.027 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00831 | 12.70 | 0.00915 | 0.026 | 0.00 |
| T S2 APARTMENT | 520.14 | 624.17 | 7.07 | 0.022 | 0.027 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00831 | 12.70 | 0.00915 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.43 | 0.43 | 0.03 | 0.03 | 0.4334 | 0.4334 | 0.4334 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.42 | 0.42 | 0.03 | 0.03 | 0.4218 | 0.4218 | 0.4218 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.49 | 0.49 | 0.04 | 0.04 | 0.4940 | 0.4940 | 0.4940 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.41 | 0.41 | 0.03 | 0.03 | 0.4077 | 0.4077 | 0.4077 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.35 | 0.35 | 0.03 | 0.03 | 0.3535 | 0.3535 | 0.3535 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.35 | 0.35 | 0.03 | 0.03 | 0.3532 | 0.3532 | 0.3532 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.37 | 0.37 | 0.03 | 0.03 | 0.3660 | 0.3660 | 0.3660 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.37 | 0.37 | 0.03 | 0.03 | 0.3685 | 0.3685 | 0.3685 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.92 | 0.92 | 0.05 | 0.05 | 0.9235 | 0.9235 | 0.9235 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.90 | 0.90 | 0.05 | 0.05 | 0.8984 | 0.8984 | 0.8984 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.89 | 0.89 | 0.05 | 0.05 | 0.8886 | 0.8886 | 0.8886 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.86 | 0.86 | 0.05 | 0.05 | 0.8636 | 0.8636 | 0.8636 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.74 | 0.74 | 0.05 | 0.05 | 0.7450 | 0.7450 | 0.7450 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.74 | 0.74 | 0.05 | 0.05 | 0.7442 | 0.7442 | 0.7442 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.77 | 0.77 | 0.05 | 0.05 | 0.7723 | 0.7723 | 0.7723 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.77 | 0.77 | 0.05 | 0.05 | 0.7715 | 0.7715 | 0.7715 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.52 | 0.52 | 0.04 | 0.04 | 0.5230 | 0.5230 | 0.5230 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.51 | 0.51 | 0.03 | 0.03 | 0.5125 | 0.5125 | 0.5125 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.50 | 0.50 | 0.04 | 0.04 | 0.4960 | 0.4960 | 0.4960 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.49 | 0.49 | 0.03 | 0.03 | 0.4854 | 0.4854 | 0.4854 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.43 | 0.43 | 0.03 | 0.03 | 0.4281 | 0.4281 | 0.4281 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.43 | 0.43 | 0.03 | 0.03 | 0.4272 | 0.4272 | 0.4272 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.44 | 0.44 | 0.03 | 0.03 | 0.4393 | 0.4393 | 0.4393 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.44 | 0.44 | 0.03 | 0.03 | 0.4384 | 0.4384 | 0.4384 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 8052.137 | 6446.238 | 0.433384 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7199.53 | 6813.62 | 0.433384 | 25.86 | 16.90 | 0.00834374 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.9888 | 24.00 | 0.00818884 | 44.0845 | 5087.39 | 0.00 | 8050.77 | 6439.49 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 10170.181 | 10170.181 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10170.18 | 10170.18 | 0.433384 | 20.60 | 14.76 | 0.00806908 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.9888 | 21.40 | 0.00915345 | 57.6109 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 7845.936 | 6278.181 | 0.421796 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7016.67 | 6642.37 | 0.421796 | 25.88 | 16.91 | 0.00834251 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.1533 | 24.00 | 0.00818300 | 44.0533 | 4953.78 | 0.00 | 7844.60 | 6271.39 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 9905.300 | 9905.300 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 9905.30 | 9905.30 | 0.421796 | 20.58 | 14.75 | 0.00807098 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.1533 | 22.01 | 0.01093191 | 66.0805 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 8997.020 | 7198.918 | 0.493971 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 8195.22 | 7792.67 | 0.493971 | 25.92 | 16.90 | 0.00831466 | 12.80 | 11.59 | 0.00800000 | 37.46 | 0.01077266 | 22.39 | 7.7142 | 23.90 | 0.00810920 | 43.9237 | 5719.31 | 0.00 | 8995.49 | 7191.86 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 11678.497 | 11678.497 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 11678.50 | 11678.50 | 0.493971 | 20.45 | 15.00 | 0.00839889 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 7.7142 | 21.10 | 0.00834027 | 53.5319 | 360.20 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 7611.526 | 6096.705 | 0.407695 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6811.44 | 6435.83 | 0.407695 | 25.91 | 16.93 | 0.00835543 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.3662 | 24.00 | 0.00819090 | 44.0953 | 4791.15 | 0.00 | 7610.23 | 6089.53 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 9582.958 | 9582.958 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 9582.96 | 9582.96 | 0.407695 | 20.57 | 14.75 | 0.00807343 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.3662 | 22.02 | 0.01093361 | 66.0690 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 6661.561 | 5335.635 | 0.353501 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5971.48 | 5637.28 | 0.353501 | 26.05 | 16.99 | 0.00836432 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 7.3421 | 24.00 | 0.00817328 | 44.0013 | 4168.57 | 0.00 | 6660.43 | 5330.11 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 8344.177 | 8344.177 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 8344.18 | 8344.18 | 0.353501 | 20.48 | 14.73 | 0.00808469 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 7.3421 | 23.08 | 0.01260361 | 71.2155 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 6656.473 | 5331.330 | 0.353194 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5967.04 | 5632.78 | 0.353194 | 26.05 | 16.99 | 0.00836469 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 7.3485 | 24.00 | 0.00817350 | 44.0024 | 4165.04 | 0.00 | 6655.34 | 5325.79 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 8337.145 | 8337.145 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 8337.14 | 8337.14 | 0.353194 | 20.48 | 14.73 | 0.00808476 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 7.3485 | 23.08 | 0.01260405 | 71.2143 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 6888.958 | 5513.691 | 0.366030 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6173.81 | 5822.73 | 0.366030 | 26.02 | 16.98 | 0.00836967 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 7.0908 | 24.00 | 0.00818607 | 44.0696 | 4312.22 | 0.00 | 6887.79 | 5508.13 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 8630.563 | 8630.563 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 8630.56 | 8630.56 | 0.366030 | 20.50 | 14.73 | 0.00808179 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 7.0908 | 22.38 | 0.00915345 | 54.2517 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 6930.017 | 5548.355 | 0.368508 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6209.72 | 5858.86 | 0.368508 | 26.01 | 16.98 | 0.00836698 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 7.0432 | 24.00 | 0.00818451 | 44.0613 | 4340.61 | 0.00 | 6928.84 | 5542.93 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 8687.199 | 8687.199 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 8687.20 | 8687.20 | 0.368508 | 20.51 | 14.73 | 0.00808124 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 7.0432 | 22.26 | 0.00915345 | 54.6516 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 17164.146 | 13739.317 | 0.923542 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 15346.86 | 14473.99 | 0.923542 | 25.81 | 16.90 | 0.00836481 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.6207 | 24.00 | 0.00822125 | 44.2570 | 21665.90 | 0.00 | 17161.23 | 13724.82 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 21637.911 | 21637.911 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | 21637.91 | 21637.91 | 0.923542 | 20.63 | 15.31 | 0.00866840 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.6207 | 21.10 | 0.00880021 | 56.4427 | 663.67 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 16720.990 | 13393.407 | 0.898399 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 14954.54 | 14102.57 | 0.898399 | 25.83 | 16.91 | 0.00836597 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.7780 | 24.00 | 0.00821823 | 44.2408 | 21084.14 | 0.00 | 16718.14 | 13378.82 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 21063.171 | 21063.171 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 21063.17 | 21063.17 | 0.898399 | 20.61 | 16.53 | 0.01006870 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.7780 | 21.13 | 0.01019996 | 65.1643 | 6.01 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 16582.884 | 13268.532 | 0.888637 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 14837.75 | 13962.01 | 0.888637 | 25.84 | 16.93 | 0.00838018 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.8414 | 24.00 | 0.00823159 | 44.3120 | 20857.13 | 0.00 | 16580.06 | 13252.95 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 20840.045 | 20840.045 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 20840.04 | 20840.04 | 0.888637 | 20.61 | 15.31 | 0.00867255 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.8414 | 21.10 | 0.00881047 | 56.5078 | 629.02 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 16140.766 | 12922.780 | 0.863608 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 14446.23 | 13592.28 | 0.863608 | 25.87 | 16.94 | 0.00838139 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.0107 | 24.00 | 0.00822830 | 44.2943 | 20278.84 | 0.00 | 16138.02 | 12907.10 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 20267.903 | 20267.903 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:10:00 | 20267.90 | 20267.90 | 0.863608 | 20.60 | 16.53 | 0.01007896 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.0107 | 21.14 | 0.01020616 | 65.1740 | 336.81 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 14028.342 | 11225.347 | 0.744960 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12573.06 | 11839.00 | 0.744960 | 26.00 | 16.98 | 0.00837973 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.9680 | 24.00 | 0.00820030 | 44.1451 | 17545.83 | 0.00 | 14025.95 | 11213.79 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 17556.011 | 17556.011 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 17556.01 | 17556.01 | 0.744960 | 20.51 | 14.74 | 0.00808037 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.9680 | 22.54 | 0.01138230 | 66.5663 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 14016.450 | 11215.305 | 0.744242 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12562.66 | 11828.49 | 0.744242 | 26.00 | 16.98 | 0.00838014 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.9748 | 24.00 | 0.00820056 | 44.1465 | 17529.31 | 0.00 | 14014.06 | 11203.71 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 17539.598 | 17539.598 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 17539.60 | 17539.60 | 0.744242 | 20.51 | 14.74 | 0.00808045 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.9748 | 22.55 | 0.01138279 | 66.5639 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 14516.109 | 11624.219 | 0.772270 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 13005.80 | 12242.61 | 0.772270 | 25.97 | 16.97 | 0.00838091 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.7216 | 24.00 | 0.00820837 | 44.1882 | 18173.86 | 0.00 | 14513.64 | 11613.06 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 18180.270 | 18180.270 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 18180.27 | 18180.27 | 0.772270 | 20.54 | 14.74 | 0.00807753 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.7216 | 21.80 | 0.00915345 | 56.2027 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 14504.095 | 11614.055 | 0.771542 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12995.30 | 12231.96 | 0.771542 | 25.97 | 16.97 | 0.00838135 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.7280 | 24.00 | 0.00820866 | 44.1898 | 18157.08 | 0.00 | 14501.63 | 11602.86 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 18163.618 | 18163.618 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 18163.62 | 18163.62 | 0.771542 | 20.53 | 14.74 | 0.00807760 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.7280 | 21.80 | 0.00915345 | 56.2010 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 9666.595 | 7736.223 | 0.523046 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 8634.33 | 8142.14 | 0.523046 | 25.72 | 16.87 | 0.00836346 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 4.9622 | 24.00 | 0.00823753 | 44.3439 | 6124.10 | 0.00 | 9664.95 | 7729.22 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 12219.530 | 12219.530 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12219.53 | 12219.53 | 0.523046 | 20.68 | 15.05 | 0.00835368 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 4.9622 | 21.10 | 0.00831193 | 53.3520 | 795.51 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 9479.914 | 7584.040 | 0.512488 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 8468.96 | 7986.46 | 0.512488 | 25.73 | 16.88 | 0.00836361 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.0644 | 24.00 | 0.00823495 | 44.3301 | 6002.60 | 0.00 | 9478.30 | 7576.99 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 11978.034 | 11978.034 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11978.03 | 11978.03 | 0.512488 | 20.68 | 15.38 | 0.00872758 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.0644 | 21.10 | 0.00870486 | 55.8384 | 656.68 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 9213.495 | 7376.356 | 0.495953 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 8237.07 | 7745.66 | 0.495953 | 25.76 | 16.90 | 0.00838244 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.2333 | 24.00 | 0.00825030 | 44.4118 | 5812.23 | 0.00 | 9211.93 | 7368.67 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 11600.249 | 11600.249 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11600.25 | 11600.25 | 0.495953 | 20.66 | 15.04 | 0.00835670 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.2333 | 21.10 | 0.00831270 | 53.3569 | 792.95 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 9026.360 | 7223.531 | 0.485387 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 8071.26 | 7589.84 | 0.485387 | 25.77 | 16.91 | 0.00838278 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.3472 | 24.00 | 0.00824762 | 44.3974 | 5690.72 | 0.00 | 9024.82 | 7215.78 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 11358.562 | 11358.562 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11358.56 | 11358.56 | 0.485387 | 20.65 | 15.37 | 0.00873062 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.3472 | 21.10 | 0.00870674 | 55.8503 | 654.27 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 7976.920 | 6386.746 | 0.428144 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7135.73 | 6740.71 | 0.428144 | 25.88 | 16.92 | 0.00835602 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.0621 | 24.00 | 0.00819990 | 44.1431 | 5031.04 | 0.00 | 7975.56 | 6379.58 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 10050.170 | 10050.170 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10050.17 | 10050.17 | 0.428144 | 20.59 | 15.59 | 0.00900190 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.0621 | 21.10 | 0.00910259 | 58.3535 | 295.07 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 7960.802 | 6373.233 | 0.427179 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7121.60 | 6726.56 | 0.427179 | 25.88 | 16.92 | 0.00835684 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 6.0758 | 24.00 | 0.00820039 | 44.1457 | 5019.86 | 0.00 | 7959.45 | 6366.03 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 10028.111 | 10028.111 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10028.11 | 10028.11 | 0.427179 | 20.59 | 15.59 | 0.00900210 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 6.0758 | 21.10 | 0.00910280 | 58.3548 | 294.98 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 8176.399 | 6541.170 | 0.439325 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7312.71 | 6906.21 | 0.439325 | 25.86 | 16.91 | 0.00835709 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.9078 | 24.00 | 0.00820526 | 44.1717 | 5160.56 | 0.00 | 8175.01 | 6533.99 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 10305.882 | 10305.882 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10305.88 | 10305.88 | 0.439325 | 20.60 | 15.02 | 0.00835732 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.9078 | 21.10 | 0.00830733 | 53.3232 | 520.24 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 8160.415 | 6535.937 | 0.438367 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7298.70 | 6892.15 | 0.438367 | 25.86 | 16.92 | 0.00835791 | 12.80 | 11.59 | 0.00800000 | 39.02 | 0.01077531 | 22.82 | 5.9207 | 24.00 | 0.00820577 | 44.1745 | 5149.45 | 0.00 | 8159.03 | 6528.78 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 10283.974 | 10283.974 | -999.0 | -999.0 | -999.000 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10283.97 | 10283.97 | 0.438367 | 20.60 | 15.02 | 0.00835748 | 40.00 | 21.18 | 0.00800000 | 12.70 | 0.00915345 | 12.70 | 5.9207 | 21.10 | 0.00830738 | 53.3235 | 520.14 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8052.137 | 6446.238 | 0.433384 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3506 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.433384 | 0.52161915 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7199.53 | 6813.62 | 0.8941 | 0.52161915 | 0.433384 | 25.86 | 16.90 | 0.00834374 | 47254.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 485.437 | 6714.09 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 5.9888 | 24.05 | 0.00818884 | 24.00 | 0.00818884 | 44.0845 | 5087.39 | 0.00 | 8050.77 | 6439.49 | 0.50101913 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.11 | 14.00 | 0.00992374 | 39253.6 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10170.181 | 10170.181 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.433384 | 0.52161915 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10170.18 | 10170.18 | 1.0000 | 0.52161915 | 0.433384 | 20.60 | 14.76 | 0.00806908 | 41185.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10170.18 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 5.9888 | 21.10 | 0.00800000 | 21.40 | 0.00915345 | 57.6109 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7845.936 | 6278.181 | 0.421796 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3483 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.421796 | 0.50767202 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7016.67 | 6642.37 | 0.8943 | 0.50767202 | 0.421796 | 25.88 | 16.91 | 0.00834251 | 47275.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 472.457 | 6544.21 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 6.1533 | 24.05 | 0.00818300 | 24.00 | 0.00818300 | 44.0533 | 4953.78 | 0.00 | 7844.60 | 6271.39 | 0.48762281 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00991971 | 39235.0 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9905.300 | 9905.300 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.421796 | 0.50767202 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 9905.30 | 9905.30 | 1.0000 | 0.50767202 | 0.421796 | 20.58 | 14.75 | 0.00807098 | 41176.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9905.30 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 6.1533 | 21.10 | 0.00800000 | 22.01 | 0.01093191 | 66.0805 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8997.020 | 7198.918 | 0.493971 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.2965 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.493971 | 0.59454089 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | Sensible | 8195.22 | 7792.67 | 0.9109 | 0.59454089 | 0.493971 | 25.92 | 16.90 | 0.00831466 | 47238.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 553.301 | 7641.92 | 37.46 | 0.01077266 | 22.39 | 0.03810604 | 7.7142 | 23.96 | 0.00810920 | 23.90 | 0.00810920 | 43.9237 | 5719.31 | 0.00 | 8995.49 | 7191.86 | 0.57106102 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.36 | 14.12 | 0.00994633 | 39570.1 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11678.497 | 11678.497 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.493971 | 0.59454089 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 11678.50 | 11678.50 | 1.0000 | 0.59454089 | 0.493971 | 20.45 | 15.00 | 0.00839889 | 41875.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11678.50 | 12.70 | 0.00915345 | 12.70 | 0.03810604 | 7.7142 | 21.10 | 0.00833582 | 21.10 | 0.00834027 | 53.5319 | 360.20 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7611.526 | 6096.705 | 0.407695 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3723 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.407695 | 0.49069934 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6811.44 | 6435.83 | 0.8949 | 0.49069934 | 0.407695 | 25.91 | 16.93 | 0.00835543 | 47338.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 456.662 | 6354.77 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 6.3662 | 24.05 | 0.00819090 | 24.00 | 0.00819090 | 44.0953 | 4791.15 | 0.00 | 7610.23 | 6089.53 | 0.47132042 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.04 | 13.97 | 0.00991964 | 39175.8 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9582.958 | 9582.958 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.407695 | 0.49069934 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 9582.96 | 9582.96 | 1.0000 | 0.49069934 | 0.407695 | 20.57 | 14.75 | 0.00807343 | 41164.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9582.96 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 6.3662 | 21.10 | 0.00800000 | 22.02 | 0.01093361 | 66.0690 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6661.561 | 5335.635 | 0.353501 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3889 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.353501 | 0.42547232 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5971.48 | 5637.28 | 0.8964 | 0.42547232 | 0.353501 | 26.05 | 16.99 | 0.00836432 | 47503.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 395.960 | 5575.53 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 7.3421 | 24.04 | 0.00817328 | 24.00 | 0.00817328 | 44.0013 | 4168.57 | 0.00 | 6660.43 | 5330.11 | 0.40866938 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.92 | 13.91 | 0.00990835 | 39024.5 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8344.177 | 8344.177 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.353501 | 0.42547232 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 8344.18 | 8344.18 | 1.0000 | 0.42547232 | 0.353501 | 20.48 | 14.73 | 0.00808469 | 41109.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8344.18 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 7.3421 | 21.10 | 0.00800000 | 23.08 | 0.01260361 | 71.2155 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6656.473 | 5331.330 | 0.353194 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3895 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.353194 | 0.42510201 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5967.04 | 5632.78 | 0.8964 | 0.42510201 | 0.353194 | 26.05 | 16.99 | 0.00836469 | 47505.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 395.615 | 5571.42 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 7.3485 | 24.04 | 0.00817350 | 24.00 | 0.00817350 | 44.0024 | 4165.04 | 0.00 | 6655.34 | 5325.79 | 0.40831370 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.92 | 13.91 | 0.00990797 | 39022.8 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8337.145 | 8337.145 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.353194 | 0.42510201 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 8337.14 | 8337.14 | 1.0000 | 0.42510201 | 0.353194 | 20.48 | 14.73 | 0.00808476 | 41109.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8337.14 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 7.3485 | 21.10 | 0.00800000 | 23.08 | 0.01260405 | 71.2143 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6888.958 | 5513.691 | 0.366030 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3988 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.366030 | 0.44055174 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6173.81 | 5822.73 | 0.8962 | 0.44055174 | 0.366030 | 26.02 | 16.98 | 0.00836967 | 47480.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 409.993 | 5763.82 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 7.0908 | 24.04 | 0.00818607 | 24.00 | 0.00818607 | 44.0696 | 4312.22 | 0.00 | 6887.79 | 5508.13 | 0.42315328 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.92 | 0.00990632 | 39045.1 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8630.563 | 8630.563 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.366030 | 0.44055174 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 8630.56 | 8630.56 | 1.0000 | 0.44055174 | 0.366030 | 20.50 | 14.73 | 0.00808179 | 41123.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8630.56 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 7.0908 | 21.10 | 0.00800000 | 22.38 | 0.00915345 | 54.2517 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6930.017 | 5548.355 | 0.368508 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3938 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.368508 | 0.44353386 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6209.72 | 5858.86 | 0.8961 | 0.44353386 | 0.368508 | 26.01 | 16.98 | 0.00836698 | 47466.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 412.768 | 5796.95 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 7.0432 | 24.04 | 0.00818451 | 24.00 | 0.00818451 | 44.0613 | 4340.61 | 0.00 | 6928.84 | 5542.93 | 0.42601763 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.92 | 0.00990917 | 39058.2 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8687.199 | 8687.199 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.368508 | 0.44353386 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 8687.20 | 8687.20 | 1.0000 | 0.44353386 | 0.368508 | 20.51 | 14.73 | 0.00808124 | 41126.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8687.20 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 7.0432 | 21.10 | 0.00800000 | 22.26 | 0.00915345 | 54.6516 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 17164.146 | 13739.317 | 0.923542 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3898 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.923542 | 1.11157043 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 15346.86 | 14473.99 | 0.8941 | 1.11157043 | 0.923542 | 25.81 | 16.90 | 0.00836481 | 47257.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 1034.467 | 14312.39 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 5.6207 | 24.06 | 0.00822125 | 24.00 | 0.00822125 | 44.2570 | 21665.90 | 0.00 | 17161.23 | 13724.82 | 1.06767180 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 14.00 | 0.00992272 | 39248.9 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21637.911 | 21637.911 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.923542 | 1.11157043 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | Sensible | 21637.91 | 21637.91 | 1.0000 | 1.11157043 | 0.923542 | 20.63 | 15.31 | 0.00866840 | 42739.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21637.91 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 5.6207 | 21.10 | 0.00863951 | 21.10 | 0.00880021 | 56.4427 | 663.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 16720.990 | 13393.407 | 0.898399 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3919 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.898399 | 1.08130890 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 14954.54 | 14102.57 | 0.8944 | 1.08130890 | 0.898399 | 25.83 | 16.91 | 0.00836597 | 47282.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 1006.304 | 13948.24 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 5.7780 | 24.06 | 0.00821823 | 24.00 | 0.00821823 | 44.2408 | 21084.14 | 0.00 | 16718.14 | 13378.82 | 1.03860537 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.08 | 13.99 | 0.00992405 | 39225.7 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21063.171 | 21063.171 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.898399 | 1.08130890 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 21063.17 | 21063.17 | 1.0000 | 1.08130890 | 0.898399 | 20.61 | 16.53 | 0.01006870 | 46281.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21063.17 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 5.7780 | 21.10 | 0.01012482 | 21.13 | 0.01019996 | 65.1643 | 6.01 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 16582.884 | 13268.532 | 0.888637 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4183 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.888637 | 1.06955894 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 14837.75 | 13962.01 | 0.8948 | 1.06955894 | 0.888637 | 25.84 | 16.93 | 0.00838018 | 47327.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 995.369 | 13842.38 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 5.8414 | 24.06 | 0.00823159 | 24.00 | 0.00823159 | 44.3120 | 20857.13 | 0.00 | 16580.06 | 13252.95 | 1.02731944 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.06 | 13.97 | 0.00991487 | 39183.2 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20840.045 | 20840.045 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.888637 | 1.06955894 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 20840.04 | 20840.04 | 1.0000 | 1.06955894 | 0.888637 | 20.61 | 15.31 | 0.00867255 | 42731.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20840.04 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 5.8414 | 21.10 | 0.00864272 | 21.10 | 0.00881047 | 56.5078 | 629.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 16140.766 | 12922.780 | 0.863608 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4206 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.863608 | 1.03943385 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 14446.23 | 13592.28 | 0.8950 | 1.03943385 | 0.863608 | 25.87 | 16.94 | 0.00838139 | 47354.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 967.334 | 13478.89 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 6.0107 | 24.05 | 0.00822830 | 24.00 | 0.00822830 | 44.2943 | 20278.84 | 0.00 | 16138.02 | 12907.10 | 0.99838407 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.03 | 13.96 | 0.00991584 | 39158.2 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20267.903 | 20267.903 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.863608 | 1.03943385 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:10:00 | Sensible | 20267.90 | 20267.90 | 1.0000 | 1.03943385 | 0.863608 | 20.60 | 16.53 | 0.01007896 | 46287.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20267.90 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 6.0107 | 21.10 | 0.01013815 | 21.14 | 0.01020616 | 65.1740 | 336.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14028.342 | 11225.347 | 0.744960 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4175 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.744960 | 0.89663043 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12573.06 | 11839.00 | 0.8963 | 0.89663043 | 0.744960 | 26.00 | 16.98 | 0.00837973 | 47488.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 834.436 | 11738.62 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 6.9680 | 24.05 | 0.00820030 | 24.00 | 0.00820030 | 44.1451 | 17545.83 | 0.00 | 14025.95 | 11213.79 | 0.86122030 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.94 | 13.92 | 0.00990440 | 39036.2 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17556.011 | 17556.011 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.744960 | 0.89663043 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 17556.01 | 17556.01 | 1.0000 | 0.89663043 | 0.744960 | 20.51 | 14.74 | 0.00808037 | 41130.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17556.01 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 6.9680 | 21.10 | 0.00800000 | 22.54 | 0.01138230 | 66.5663 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14016.450 | 11215.305 | 0.744242 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4183 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.744242 | 0.89576622 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12562.66 | 11828.49 | 0.8963 | 0.89576622 | 0.744242 | 26.00 | 16.98 | 0.00838014 | 47490.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 833.632 | 11729.03 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 6.9748 | 24.05 | 0.00820056 | 24.00 | 0.00820056 | 44.1465 | 17529.31 | 0.00 | 14014.06 | 11203.71 | 0.86039022 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.94 | 13.91 | 0.00990399 | 39034.4 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17539.598 | 17539.598 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.744242 | 0.89576622 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 17539.60 | 17539.60 | 1.0000 | 0.89576622 | 0.744242 | 20.51 | 14.74 | 0.00808045 | 41130.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17539.60 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 6.9748 | 21.10 | 0.00800000 | 22.55 | 0.01138279 | 66.5639 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14516.109 | 11624.219 | 0.772270 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4197 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.772270 | 0.92950030 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 13005.80 | 12242.61 | 0.8960 | 0.92950030 | 0.772270 | 25.97 | 16.97 | 0.00838091 | 47456.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 865.026 | 12140.77 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 6.7216 | 24.05 | 0.00820837 | 24.00 | 0.00820837 | 44.1882 | 18173.86 | 0.00 | 14513.64 | 11613.06 | 0.89279207 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.93 | 0.00991085 | 39065.9 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18180.270 | 18180.270 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.772270 | 0.92950030 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 18180.27 | 18180.27 | 1.0000 | 0.92950030 | 0.772270 | 20.54 | 14.74 | 0.00807753 | 41144.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18180.27 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 6.7216 | 21.10 | 0.00800000 | 21.80 | 0.00915345 | 56.2027 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14504.095 | 11614.055 | 0.771542 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4205 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.771542 | 0.92862349 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12995.30 | 12231.96 | 0.8960 | 0.92862349 | 0.771542 | 25.97 | 16.97 | 0.00838135 | 47458.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 864.210 | 12131.09 | 39.02 | 0.01077531 | 22.82 | 0.05190911 | 6.7280 | 24.05 | 0.00820866 | 24.00 | 0.00820866 | 44.1898 | 18157.08 | 0.00 | 14501.63 | 11602.86 | 0.89194988 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.93 | 0.00991044 | 39064.0 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18163.618 | 18163.618 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.771542 | 0.92862349 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 18163.62 | 18163.62 | 1.0000 | 0.92862349 | 0.771542 | 20.53 | 14.74 | 0.00807760 | 41144.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18163.62 | 12.70 | 0.00915345 | 12.70 | 0.05190911 | 6.7280 | 21.10 | 0.00800000 | 21.80 | 0.00915345 | 56.2010 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9666.595 | 7736.223 | 0.523046 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3873 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.523046 | 0.62953535 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 8634.33 | 8142.14 | 0.8932 | 0.62953535 | 0.523046 | 25.72 | 16.87 | 0.00836346 | 47159.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 585.868 | 8048.47 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 4.9622 | 24.06 | 0.00823753 | 24.00 | 0.00823753 | 44.3439 | 6124.10 | 0.00 | 9664.95 | 7729.22 | 0.60467346 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.18 | 14.03 | 0.00992951 | 39338.6 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12219.530 | 12219.530 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.523046 | 0.62953535 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12219.53 | 12219.53 | 1.0000 | 0.62953535 | 0.523046 | 20.68 | 15.05 | 0.00835368 | 41996.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12219.53 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 4.9622 | 21.10 | 0.00831193 | 21.10 | 0.00831193 | 53.3520 | 795.51 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9479.914 | 7584.040 | 0.512488 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3875 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.512488 | 0.61682761 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 8468.96 | 7986.46 | 0.8934 | 0.61682761 | 0.512488 | 25.73 | 16.88 | 0.00836361 | 47174.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 574.042 | 7894.92 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 5.0644 | 24.06 | 0.00823495 | 24.00 | 0.00823495 | 44.3301 | 6002.60 | 0.00 | 9478.30 | 7576.99 | 0.59246758 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.17 | 14.02 | 0.00992643 | 39324.4 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11978.034 | 11978.034 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.512488 | 0.61682761 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11978.03 | 11978.03 | 1.0000 | 0.61682761 | 0.512488 | 20.68 | 15.38 | 0.00872758 | 42937.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11978.03 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 5.0644 | 21.10 | 0.00870486 | 21.10 | 0.00870486 | 55.8384 | 656.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9213.495 | 7376.356 | 0.495953 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4225 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.495953 | 0.59692712 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 8237.07 | 7745.66 | 0.8940 | 0.59692712 | 0.495953 | 25.76 | 16.90 | 0.00838244 | 47247.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 555.521 | 7681.55 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 5.2333 | 24.06 | 0.00825030 | 24.00 | 0.00825030 | 44.4118 | 5812.23 | 0.00 | 9211.93 | 7368.67 | 0.57335301 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.11 | 14.00 | 0.00992418 | 39255.6 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11600.249 | 11600.249 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.495953 | 0.59692712 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11600.25 | 11600.25 | 1.0000 | 0.59692712 | 0.495953 | 20.66 | 15.04 | 0.00835670 | 41981.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11600.25 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 5.2333 | 21.10 | 0.00831270 | 21.10 | 0.00831270 | 53.3569 | 792.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9026.360 | 7223.531 | 0.485387 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.4232 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.485387 | 0.58420883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 8071.26 | 7589.84 | 0.8942 | 0.58420883 | 0.485387 | 25.77 | 16.91 | 0.00838278 | 47265.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 543.685 | 7527.57 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 5.3472 | 24.06 | 0.00824762 | 24.00 | 0.00824762 | 44.3974 | 5690.72 | 0.00 | 9024.82 | 7215.78 | 0.56113699 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00992065 | 39239.3 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11358.562 | 11358.562 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.485387 | 0.58420883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11358.56 | 11358.56 | 1.0000 | 0.58420883 | 0.485387 | 20.65 | 15.37 | 0.00873062 | 42921.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11358.56 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 5.3472 | 21.10 | 0.00870674 | 21.10 | 0.00870674 | 55.8503 | 654.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7976.920 | 6386.746 | 0.428144 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3734 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.428144 | 0.51531223 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7135.73 | 6740.71 | 0.8945 | 0.51531223 | 0.428144 | 25.88 | 16.92 | 0.00835602 | 47302.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 479.568 | 6656.16 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 6.0621 | 24.06 | 0.00819990 | 24.00 | 0.00819990 | 44.1431 | 5031.04 | 0.00 | 7975.56 | 6379.58 | 0.49496129 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.07 | 13.98 | 0.00992042 | 39208.9 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10050.170 | 10050.170 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.428144 | 0.51531223 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10050.17 | 10050.17 | 1.0000 | 0.51531223 | 0.428144 | 20.59 | 15.59 | 0.00900190 | 43548.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10050.17 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 6.0621 | 21.10 | 0.00899212 | 21.10 | 0.00910259 | 58.3535 | 295.07 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7960.802 | 6373.233 | 0.427179 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3749 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.427179 | 0.51415071 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7121.60 | 6726.56 | 0.8946 | 0.51415071 | 0.427179 | 25.88 | 16.92 | 0.00835684 | 47306.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 478.487 | 6643.11 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 6.0758 | 24.06 | 0.00820039 | 24.00 | 0.00820039 | 44.1457 | 5019.86 | 0.00 | 7959.45 | 6366.03 | 0.49384564 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.07 | 13.98 | 0.00991960 | 39205.1 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10028.111 | 10028.111 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.427179 | 0.51415071 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10028.11 | 10028.11 | 1.0000 | 0.51415071 | 0.427179 | 20.59 | 15.59 | 0.00900210 | 43548.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10028.11 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 6.0758 | 21.10 | 0.00899231 | 21.10 | 0.00910280 | 58.3548 | 294.98 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8176.399 | 6541.170 | 0.439325 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3754 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.439325 | 0.52876959 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7312.71 | 6906.21 | 0.8944 | 0.52876959 | 0.439325 | 25.86 | 16.91 | 0.00835709 | 47283.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 492.092 | 6820.61 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 5.9078 | 24.06 | 0.00820526 | 24.00 | 0.00820526 | 44.1717 | 5160.56 | 0.00 | 8175.01 | 6533.99 | 0.50788718 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.09 | 13.99 | 0.00991783 | 39226.3 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10305.882 | 10305.882 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.439325 | 0.52876959 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10305.88 | 10305.88 | 1.0000 | 0.52876959 | 0.439325 | 20.60 | 15.02 | 0.00835732 | 41924.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10305.88 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 5.9078 | 21.10 | 0.00830733 | 21.10 | 0.00830733 | 53.3232 | 520.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8160.415 | 6535.937 | 0.438367 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.3769 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.438367 | 0.52761601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | DUBAI.INTL.AP_ARE ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7298.70 | 6892.15 | 0.8944 | 0.52761601 | 0.438367 | 25.86 | 16.92 | 0.00835791 | 47286.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 491.018 | 6807.68 | 39.02 | 0.01077531 | 22.82 | 0.02595455 | 5.9207 | 24.06 | 0.00820577 | 24.00 | 0.00820577 | 44.1745 | 5149.45 | 0.00 | 8159.03 | 6528.78 | 0.50677916 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.08 | 13.99 | 0.00992339 | 39222.6 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10283.974 | 10283.974 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.438367 | 0.52761601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | DUBAI.INTL.AP_ARE ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10283.97 | 10283.97 | 1.0000 | 0.52761601 | 0.438367 | 20.60 | 15.02 | 0.00835748 | 41924.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10283.97 | 12.70 | 0.00915345 | 12.70 | 0.02595455 | 5.9207 | 21.10 | 0.00830738 | 21.10 | 0.00830738 | 53.3235 | 520.14 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 5227.50 | 1047.83 | 1027.33 |
| G NW APARTMENT | 7070.67 | 1454.50 | 1357.50 |
| OFFICE | 1750.00 | 168.67 | 168.67 |
| G NE APARTMENT | 7089.50 | 1453.17 | 1369.17 |
| G N1 APARTMENT | 6866.00 | 1586.33 | 1555.83 |
| G N2 APARTMENT | 6867.00 | 1585.33 | 1555.50 |
| G S1 APARTMENT | 5217.00 | 1171.83 | 1169.17 |
| G S2 APARTMENT | 5394.50 | 992.00 | 992.00 |
| M SW APARTMENT | 4934.17 | 1414.50 | 1341.67 |
| M NW APARTMENT | 6690.50 | 2091.83 | 1850.00 |
| M SE APARTMENT | 4962.00 | 1451.33 | 1378.67 |
| M NE APARTMENT | 6701.17 | 2075.17 | 1860.00 |
| M N1 APARTMENT | 6453.00 | 2072.83 | 1971.00 |
| M N2 APARTMENT | 6453.67 | 2072.00 | 1971.00 |
| M S1 APARTMENT | 4899.17 | 1453.00 | 1438.33 |
| M S2 APARTMENT | 4901.50 | 1453.67 | 1439.00 |
| T SW APARTMENT | 4735.17 | 2275.83 | 1568.17 |
| T NW APARTMENT | 6721.50 | 3100.83 | 2063.83 |
| T SE APARTMENT | 4743.67 | 2333.67 | 1628.33 |
| T NE APARTMENT | 6745.17 | 3092.00 | 2083.83 |
| T N1 APARTMENT | 6582.50 | 2916.50 | 2030.83 |
| T N2 APARTMENT | 6584.67 | 2915.00 | 2032.33 |
| T S1 APARTMENT | 4760.50 | 2043.17 | 1511.33 |
| T S2 APARTMENT | 4761.50 | 2054.33 | 1522.00 |
| T CORRIDOR | 8756.83 | 8710.33 | 8708.00 |
| G CORRIDOR | 8543.00 | 6680.17 | 6569.17 |
| M CORRIDOR | 8760.00 | 8755.17 | 8755.17 |
| Facility | 8760.00 | 8759.00 | 8755.17 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.17 | 0.00 | 0.17 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.17 | 0.00 | 0.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.125 | 0.000 | 0.043 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.145 | 0.000 | 0.047 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.527 | 0.178 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.145 | 0.000 | 0.047 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.087 | 0.000 | 0.047 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.087 | 0.000 | 0.047 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.075 | 0.000 | 0.043 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.075 | 0.000 | 0.043 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.180 | 0.000 | 0.050 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.208 | 0.000 | 0.056 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.180 | 0.000 | 0.050 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.208 | 0.000 | 0.056 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.126 | 0.000 | 0.056 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.126 | 0.000 | 0.056 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.109 | 0.000 | 0.050 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.109 | 0.000 | 0.050 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.238 | 0.000 | 0.057 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.275 | 0.000 | 0.065 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.238 | 0.000 | 0.057 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.275 | 0.000 | 0.065 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.166 | 0.000 | 0.066 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.166 | 0.000 | 0.066 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.144 | 0.000 | 0.057 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.144 | 0.000 | 0.057 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.513 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.20 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 108569.76 | 927072.54 | 329699.75 | 1256772.29 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 2615.00 |
| G NW APARTMENT | 818502.78 | 108480.71 | 926983.49 | 329699.75 | 1256683.24 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 329699.75 | 1531411.72 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 108514.75 | 927017.52 | 329699.75 | 1256717.27 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 0.00 |
| G N1 APARTMENT | 818502.78 | 108564.69 | 927067.47 | 198866.52 | 1125933.99 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 0.00 |
| G N2 APARTMENT | 818502.78 | 108564.96 | 927067.73 | 198866.52 | 1125934.25 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 0.00 |
| G S1 APARTMENT | 818502.78 | 108603.64 | 927106.41 | 198866.52 | 1125972.93 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 108608.08 | 927110.85 | 198866.52 | 1125977.37 | 818502.78 | 0.00 | 7331.50 | 1428.50 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 129044.84 | 1766050.39 | 473802.25 | 2239852.65 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 128656.65 | 1765662.21 | 473802.25 | 2239464.46 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 0.00 |
| M SE APARTMENT | 1637005.55 | 129071.52 | 1766077.07 | 473802.25 | 2239879.33 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 128741.54 | 1765747.09 | 473802.25 | 2239549.35 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 128851.51 | 1765857.06 | 285785.49 | 2051642.55 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 128852.23 | 1765857.78 | 285785.49 | 2051643.27 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 129126.72 | 1766132.28 | 285785.49 | 2051917.77 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 129126.77 | 1766132.32 | 285785.49 | 2051917.82 | 1637005.55 | 0.00 | 7327.33 | 1432.67 | 2615.00 |
| T SW APARTMENT | 818502.78 | 151458.55 | 969961.32 | 626738.58 | 1596699.90 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 2615.00 |
| T NW APARTMENT | 818502.78 | 149939.61 | 968442.38 | 626738.58 | 1595180.96 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 0.00 |
| T SE APARTMENT | 818502.78 | 151773.68 | 970276.46 | 626738.58 | 1597015.03 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 2615.00 |
| T NE APARTMENT | 818502.78 | 150461.15 | 968963.92 | 626738.58 | 1595702.50 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 0.00 |
| T N1 APARTMENT | 818502.78 | 150976.40 | 969479.18 | 378032.80 | 1347511.98 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 0.00 |
| T N2 APARTMENT | 818502.78 | 150990.06 | 969492.83 | 378032.80 | 1347525.63 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 0.00 |
| T S1 APARTMENT | 818502.78 | 152276.40 | 970779.17 | 378032.80 | 1348811.97 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 152281.93 | 970784.70 | 378032.80 | 1348817.50 | 818502.78 | 0.00 | 7322.33 | 1437.67 | 2615.00 |
| Total Facility | 39671342.50 | 4033007.88 | 43704350.38 | 12210052.55 | 55914402.93 | 39671342.50 | 0.00 | 8760.00 | 1439.33 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0031 | 0.0291 | 0.0090 | 0.0381 | 0.0260 | 0.00 | 5248.50 | 896.50 |
| G NW APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0105 | 0.0398 | 0.0260 | 0.00 | 7331.50 | 1428.50 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0129 | 0.0510 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0105 | 0.0399 | 0.0260 | 0.00 | 7331.50 | 1428.50 |
| G N1 APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0063 | 0.0357 | 0.0260 | 0.00 | 7331.50 | 1428.50 |
| G N2 APARTMENT | 0.0260 | 0.0034 | 0.0294 | 0.0063 | 0.0357 | 0.0260 | 0.00 | 7331.50 | 1428.50 |
| G S1 APARTMENT | 0.0260 | 0.0031 | 0.0291 | 0.0054 | 0.0345 | 0.0260 | 0.00 | 5248.50 | 896.50 |
| G S2 APARTMENT | 0.0260 | 0.0031 | 0.0291 | 0.0054 | 0.0345 | 0.0260 | 0.00 | 5248.50 | 896.50 |
| M SW APARTMENT | 0.0519 | 0.0036 | 0.0555 | 0.0130 | 0.0685 | 0.0519 | 0.00 | 5246.83 | 898.17 |
| M NW APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0150 | 0.0710 | 0.0519 | 0.00 | 7327.33 | 1432.67 |
| M SE APARTMENT | 0.0519 | 0.0036 | 0.0555 | 0.0130 | 0.0685 | 0.0519 | 0.00 | 5246.83 | 898.17 |
| M NE APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0150 | 0.0710 | 0.0519 | 0.00 | 7327.33 | 1432.67 |
| M N1 APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0091 | 0.0651 | 0.0519 | 0.00 | 7327.33 | 1432.67 |
| M N2 APARTMENT | 0.0519 | 0.0041 | 0.0560 | 0.0091 | 0.0651 | 0.0519 | 0.00 | 7327.33 | 1432.67 |
| M S1 APARTMENT | 0.0519 | 0.0036 | 0.0555 | 0.0078 | 0.0634 | 0.0519 | 0.00 | 5246.83 | 898.17 |
| M S2 APARTMENT | 0.0519 | 0.0036 | 0.0555 | 0.0078 | 0.0634 | 0.0519 | 0.00 | 5246.83 | 898.17 |
| T SW APARTMENT | 0.0260 | 0.0042 | 0.0301 | 0.0172 | 0.0473 | 0.0260 | 0.00 | 5245.83 | 899.17 |
| T NW APARTMENT | 0.0260 | 0.0048 | 0.0307 | 0.0199 | 0.0506 | 0.0260 | 0.00 | 7322.33 | 1437.67 |
| T SE APARTMENT | 0.0260 | 0.0042 | 0.0301 | 0.0172 | 0.0473 | 0.0260 | 0.00 | 5245.83 | 899.17 |
| T NE APARTMENT | 0.0260 | 0.0048 | 0.0307 | 0.0199 | 0.0506 | 0.0260 | 0.00 | 7322.33 | 1437.67 |
| T N1 APARTMENT | 0.0260 | 0.0048 | 0.0307 | 0.0120 | 0.0427 | 0.0260 | 0.00 | 7322.33 | 1437.67 |
| T N2 APARTMENT | 0.0260 | 0.0048 | 0.0307 | 0.0120 | 0.0427 | 0.0260 | 0.00 | 7322.33 | 1437.67 |
| T S1 APARTMENT | 0.0260 | 0.0042 | 0.0301 | 0.0104 | 0.0405 | 0.0260 | 0.00 | 5245.83 | 899.17 |
| T S2 APARTMENT | 0.0260 | 0.0042 | 0.0301 | 0.0104 | 0.0405 | 0.0260 | 0.00 | 5245.83 | 899.17 |
| Total Facility | 1.2580 | 0.1204 | 1.3784 | 0.3647 | 1.7431 | 1.2580 | 0.00 | 8760.00 | 1439.33 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 108569.76 | 108569.76 | 818502.78 | 8414.00 | 29.67 | 316.33 | 532.00 |
| SPLIT GNW | 0.00 | 108480.71 | 108480.71 | 818502.78 | 8414.13 | 34.03 | 311.84 | 0.00 |
| SPLIT OFFICE | 1740849.09 | 0.00 | 1740849.09 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 108514.75 | 108514.75 | 818502.78 | 8413.47 | 33.53 | 313.00 | 0.00 |
| SPLIT GN1 | 0.00 | 108564.69 | 108564.69 | 818502.78 | 8413.00 | 33.17 | 313.83 | 0.00 |
| SPLIT GN2 | 0.00 | 108564.96 | 108564.96 | 818502.78 | 8413.00 | 33.17 | 313.83 | 0.00 |
| SPLIT GS1 | 0.00 | 108603.64 | 108603.64 | 818502.78 | 8413.83 | 29.33 | 316.83 | 532.00 |
| SPLIT GS2 | 0.00 | 108608.08 | 108608.08 | 818502.78 | 8413.83 | 29.33 | 316.83 | 532.00 |
| SPLIT MSW | 0.00 | 129044.84 | 129044.84 | 1637005.55 | 8750.50 | 2.00 | 7.50 | 534.50 |
| SPLIT MNW | 0.00 | 128656.65 | 128656.65 | 1637005.55 | 8752.33 | 2.33 | 5.33 | 0.00 |
| SPLIT MSE | 0.00 | 129071.52 | 129071.52 | 1637005.55 | 8750.50 | 1.83 | 7.67 | 534.50 |
| SPLIT MNE | 0.00 | 128741.54 | 128741.54 | 1637005.55 | 8752.33 | 2.33 | 5.33 | 0.00 |
| SPLIT MN1 | 0.00 | 128851.51 | 128851.51 | 1637005.55 | 8752.33 | 2.33 | 5.33 | 0.00 |
| SPLIT MN2 | 0.00 | 128852.23 | 128852.23 | 1637005.55 | 8752.33 | 2.33 | 5.33 | 0.00 |
| SPLIT MS1 | 0.00 | 129126.72 | 129126.72 | 1637005.55 | 8750.50 | 1.83 | 7.67 | 534.50 |
| SPLIT MS2 | 0.00 | 129126.77 | 129126.77 | 1637005.55 | 8750.50 | 1.83 | 7.67 | 534.50 |
| SPLIT TSW | 0.00 | 151458.55 | 151458.55 | 818502.78 | 7914.67 | 35.96 | 809.37 | 538.50 |
| SPLIT TNW | 0.00 | 149939.61 | 149939.61 | 818502.78 | 7946.54 | 35.19 | 778.27 | 0.00 |
| SPLIT TSE | 0.00 | 151773.68 | 151773.68 | 818502.78 | 7907.43 | 36.66 | 815.91 | 538.50 |
| SPLIT TNE | 0.00 | 150461.15 | 150461.15 | 818502.78 | 7938.78 | 36.69 | 784.53 | 0.00 |
| SPLIT TN1 | 0.00 | 150976.40 | 150976.40 | 818502.78 | 7922.03 | 37.18 | 800.79 | 0.00 |
| SPLIT TN2 | 0.00 | 150990.06 | 150990.06 | 818502.78 | 7921.98 | 37.27 | 800.75 | 0.00 |
| SPLIT TS1 | 0.00 | 152276.40 | 152276.40 | 818502.78 | 7898.33 | 34.21 | 827.46 | 538.50 |
| SPLIT TS2 | 0.00 | 152281.93 | 152281.93 | 818502.78 | 7898.33 | 34.05 | 827.62 | 538.50 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0031 | 0.0031 | 0.0260 | 5919.50 | 18.50 | 207.00 |
| SPLIT GNW | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 8414.13 | 34.03 | 311.84 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0552 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 8413.47 | 33.53 | 313.00 |
| SPLIT GN1 | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 8413.00 | 33.17 | 313.83 |
| SPLIT GN2 | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 8413.00 | 33.17 | 313.83 |
| SPLIT GS1 | 0.0000 | 0.0031 | 0.0031 | 0.0260 | 5919.50 | 18.50 | 207.00 |
| SPLIT GS2 | 0.0000 | 0.0031 | 0.0031 | 0.0260 | 5919.50 | 18.50 | 207.00 |
| SPLIT MSW | 0.0000 | 0.0036 | 0.0036 | 0.0519 | 6139.00 | 0.83 | 5.17 |
| SPLIT MNW | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 8752.33 | 2.33 | 5.33 |
| SPLIT MSE | 0.0000 | 0.0036 | 0.0036 | 0.0519 | 6139.00 | 0.83 | 5.17 |
| SPLIT MNE | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 8752.33 | 2.33 | 5.33 |
| SPLIT MN1 | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 8752.33 | 2.33 | 5.33 |
| SPLIT MN2 | 0.0000 | 0.0041 | 0.0041 | 0.0519 | 8752.33 | 2.33 | 5.33 |
| SPLIT MS1 | 0.0000 | 0.0036 | 0.0036 | 0.0519 | 6139.00 | 0.83 | 5.17 |
| SPLIT MS2 | 0.0000 | 0.0036 | 0.0036 | 0.0519 | 6139.00 | 0.83 | 5.17 |
| SPLIT TSW | 0.0000 | 0.0042 | 0.0042 | 0.0260 | 5639.53 | 24.81 | 480.67 |
| SPLIT TNW | 0.0000 | 0.0048 | 0.0048 | 0.0260 | 7946.54 | 35.19 | 778.27 |
| SPLIT TSE | 0.0000 | 0.0042 | 0.0042 | 0.0260 | 5637.63 | 24.96 | 482.42 |
| SPLIT TNE | 0.0000 | 0.0048 | 0.0048 | 0.0260 | 7938.78 | 36.69 | 784.53 |
| SPLIT TN1 | 0.0000 | 0.0048 | 0.0048 | 0.0260 | 7922.03 | 37.18 | 800.79 |
| SPLIT TN2 | 0.0000 | 0.0048 | 0.0048 | 0.0260 | 7921.98 | 37.27 | 800.75 |
| SPLIT TS1 | 0.0000 | 0.0042 | 0.0042 | 0.0260 | 5631.78 | 22.64 | 490.58 |
| SPLIT TS2 | 0.0000 | 0.0042 | 0.0042 | 0.0260 | 5631.78 | 22.64 | 490.58 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 181.18 | 1793.73 | 17-MAR-07:10 | 12556.76 | 10-AUG-16:10 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| ElectricityPurchased:Plant | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| Cogeneration:ElectricityPurchased | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| General:Cogeneration:ElectricityPurchased | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| ElectricityNet:Plant | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| Cogeneration:ElectricityNet | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| General:Cogeneration:ElectricityNet | 1646.02 | 17102.88 | 20-JAN-04:00 | 114674.51 | 30-JUL-17:10 |
| Electricity:HVAC | 707.22 | 1793.73 | 06-MAR-06:10 | 62762.88 | 10-AUG-16:00 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 181.18 | 1793.73 | 17-MAR-07:10 | 12556.76 | 10-AUG-16:10 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 526.04 | 0.00 | 01-JAN-09:20 | 50379.87 | 10-AUG-16:00 |
| General:Cooling:Electricity | 526.04 | 0.00 | 01-JAN-09:20 | 50379.87 | 10-AUG-16:00 |
| ExteriorLights:Electricity | 50.10 | 0.00 | 01-JAN-07:10 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 50.10 | 0.00 | 01-JAN-07:10 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 330.81 | 1950.00 | 31-JUL-16:10 | 37007.56 | 01-JAN-07:10 |
| WaterSystems:Electricity | 330.81 | 1950.00 | 31-JUL-16:10 | 37007.56 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Electricity | 330.81 | 1950.00 | 31-JUL-16:10 | 37007.56 | 01-JAN-07:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 0.01 | 0.00 | 01-JAN-00:10 | 524.31 | 20-JAN-07:00 |
| NaturalGas:HVAC | 0.01 | 0.00 | 01-JAN-00:10 | 524.31 | 20-JAN-07:00 |
| Heating:NaturalGas | 0.01 | 0.00 | 01-JAN-00:10 | 524.31 | 20-JAN-07:00 |
| General:Heating:NaturalGas | 0.01 | 0.00 | 01-JAN-00:10 | 524.31 | 20-JAN-07:00 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 3151.02 | 5341.48 | 01-JAN-10:00 | 256429.98 | 10-AUG-16:00 |
| EnergyTransfer:Building | 1223.16 | 3649.81 | 25-MAR-08:40 | 106887.08 | 21-MAY-13:00 |
| EnergyTransfer:Zone:G SW APARTMENT | 43.49 | 149.32 | 16-DEC-06:50 | 3087.05 | 21-MAY-13:00 |
| Heating:EnergyTransfer | 4.11 | 0.00 | 01-JAN-04:30 | 928.31 | 13-JUL-17:10 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer | 4.11 | 0.00 | 01-JAN-04:30 | 928.31 | 13-JUL-17:10 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer | 1219.05 | 3357.76 | 25-MAR-08:40 | 106887.08 | 21-MAY-13:00 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 43.49 | 149.32 | 16-DEC-06:50 | 3087.05 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer | 1219.05 | 3357.76 | 25-MAR-08:40 | 106887.08 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 43.49 | 149.32 | 16-DEC-06:50 | 3087.05 | 21-MAY-13:00 |
| EnergyTransfer:Zone:G NW APARTMENT | 39.57 | 76.09 | 25-MAR-08:40 | 3047.94 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 39.57 | 76.09 | 25-MAR-08:40 | 3047.94 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 39.57 | 76.09 | 25-MAR-08:40 | 3047.94 | 21-MAY-13:00 |
| EnergyTransfer:Zone:OFFICE | 32.94 | 0.07 | 31-DEC-03:30 | 5225.06 | 05-SEP-08:10 |
| Heating:EnergyTransfer:Zone:OFFICE | 4.11 | 0.00 | 01-JAN-04:30 | 928.31 | 13-JUL-17:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 4.11 | 0.00 | 01-JAN-04:30 | 928.31 | 13-JUL-17:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 28.83 | 0.00 | 01-JAN-00:10 | 5225.06 | 05-SEP-08:10 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 28.83 | 0.00 | 01-JAN-00:10 | 5225.06 | 05-SEP-08:10 |
| EnergyTransfer:Zone:G NE APARTMENT | 39.71 | 133.43 | 16-DEC-07:00 | 3145.18 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 39.71 | 133.43 | 16-DEC-07:00 | 3145.18 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 39.71 | 133.43 | 16-DEC-07:00 | 3145.18 | 21-MAY-13:00 |
| EnergyTransfer:Zone:G N1 APARTMENT | 32.70 | 161.34 | 01-JAN-10:20 | 2153.60 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 32.70 | 161.34 | 01-JAN-10:20 | 2153.60 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 32.70 | 161.34 | 01-JAN-10:20 | 2153.60 | 21-MAY-13:00 |
| EnergyTransfer:Zone:G N2 APARTMENT | 32.70 | 161.28 | 01-JAN-10:20 | 2157.24 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 32.70 | 161.28 | 01-JAN-10:20 | 2157.24 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 32.70 | 161.28 | 01-JAN-10:20 | 2157.24 | 21-MAY-13:00 |
| EnergyTransfer:Zone:G S1 APARTMENT | 36.87 | 201.36 | 16-DEC-06:20 | 2199.07 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 36.87 | 201.36 | 16-DEC-06:20 | 2199.07 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 36.87 | 201.36 | 16-DEC-06:20 | 2199.07 | 21-MAY-13:00 |
| EnergyTransfer:Zone:G S2 APARTMENT | 40.27 | 214.17 | 21-FEB-08:50 | 2364.32 | 04-SEP-17:00 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 40.27 | 214.17 | 21-FEB-08:50 | 2364.32 | 04-SEP-17:00 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 40.27 | 214.17 | 21-FEB-08:50 | 2364.32 | 04-SEP-17:00 |
| EnergyTransfer:Zone:M SW APARTMENT | 85.45 | 87.83 | 25-MAR-09:00 | 7650.70 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 85.45 | 87.83 | 25-MAR-09:00 | 7650.70 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 85.45 | 87.83 | 25-MAR-09:00 | 7650.70 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M NW APARTMENT | 77.05 | 80.72 | 25-MAR-09:00 | 7541.60 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 77.05 | 80.72 | 25-MAR-09:00 | 7541.60 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 77.05 | 80.72 | 25-MAR-09:00 | 7541.60 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M SE APARTMENT | 85.79 | 227.55 | 16-DEC-07:40 | 7884.44 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 85.79 | 227.55 | 16-DEC-07:40 | 7884.44 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 85.79 | 227.55 | 16-DEC-07:40 | 7884.44 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M NE APARTMENT | 77.37 | 151.56 | 25-MAR-08:40 | 7772.91 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 77.37 | 151.56 | 25-MAR-08:40 | 7772.91 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 77.37 | 151.56 | 25-MAR-08:40 | 7772.91 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M N1 APARTMENT | 62.84 | 118.36 | 25-MAR-08:50 | 5113.71 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 62.84 | 118.36 | 25-MAR-08:50 | 5113.71 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 62.84 | 118.36 | 25-MAR-08:50 | 5113.71 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M N2 APARTMENT | 62.85 | 118.55 | 25-MAR-08:50 | 5122.30 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 62.85 | 118.55 | 25-MAR-08:50 | 5122.30 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 62.85 | 118.55 | 25-MAR-08:50 | 5122.30 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M S1 APARTMENT | 71.42 | 248.28 | 16-DEC-07:20 | 5223.71 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 71.42 | 248.28 | 16-DEC-07:20 | 5223.71 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 71.42 | 248.28 | 16-DEC-07:20 | 5223.71 | 21-MAY-13:00 |
| EnergyTransfer:Zone:M S2 APARTMENT | 71.44 | 248.28 | 16-DEC-07:20 | 5232.32 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 71.44 | 248.28 | 16-DEC-07:20 | 5232.32 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 71.44 | 248.28 | 16-DEC-07:20 | 5232.32 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T SW APARTMENT | 47.51 | 0.72 | 05-APR-08:00 | 5260.77 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 25.06 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 25.06 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 47.51 | 0.00 | 15-FEB-08:00 | 5260.77 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 47.51 | 0.00 | 15-FEB-08:00 | 5260.77 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T NW APARTMENT | 43.12 | 0.60 | 30-DEC-10:20 | 5187.27 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 33.12 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 33.12 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 43.12 | 0.00 | 01-JAN-09:30 | 5187.27 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 43.12 | 0.00 | 01-JAN-09:30 | 5187.27 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T SE APARTMENT | 47.71 | 2.82 | 05-APR-08:00 | 5422.41 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 18.82 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 18.82 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 47.71 | 0.00 | 15-FEB-08:00 | 5422.41 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 47.71 | 0.00 | 15-FEB-08:00 | 5422.41 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T NE APARTMENT | 43.30 | 3.30 | 05-APR-08:00 | 5352.40 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 26.80 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 26.80 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 43.30 | 0.00 | 15-FEB-08:00 | 5352.40 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 43.30 | 0.00 | 15-FEB-08:00 | 5352.40 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T N1 APARTMENT | 35.00 | 4.07 | 16-JAN-10:40 | 3647.79 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 18.31 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 18.31 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 35.00 | 0.00 | 16-JAN-10:50 | 3647.79 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 35.00 | 0.00 | 16-JAN-10:50 | 3647.79 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T N2 APARTMENT | 35.02 | 4.69 | 16-JAN-10:50 | 3656.30 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 18.24 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 18.24 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 35.02 | 0.00 | 16-JAN-10:50 | 3656.30 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 35.02 | 0.00 | 16-JAN-10:50 | 3656.30 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T S1 APARTMENT | 39.51 | 9.97 | 15-FEB-08:00 | 3717.61 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 9.97 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 9.97 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 39.51 | 0.00 | 15-FEB-08:00 | 3717.61 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 39.51 | 0.00 | 15-FEB-08:00 | 3717.61 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T S2 APARTMENT | 39.52 | 9.93 | 15-FEB-08:00 | 3726.12 | 21-MAY-13:00 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 9.93 | 15-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 9.93 | 15-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 39.52 | 0.00 | 15-FEB-08:00 | 3726.12 | 21-MAY-13:00 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 39.52 | 0.00 | 15-FEB-08:00 | 3726.12 | 21-MAY-13:00 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 1927.86 | 0.00 | 06-MAR-06:10 | 170082.63 | 22-AUG-17:00 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 30-APR-21:20 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 21-JUL-16:30 |
| HeatingCoils:EnergyTransfer | 0.01 | 0.00 | 01-JAN-00:10 | 419.45 | 20-JAN-07:00 |
| CoolingCoils:EnergyTransfer | 1927.85 | 0.00 | 01-JAN-09:20 | 170082.63 | 22-AUG-17:00 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 5.560 | -1.103 | 0.000 | -47.950 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 11.883 | 0.000 | 2.471 | 14.248 | 0.000 | -1.519 | 0.000 | -0.818 | -0.000 |
| G NW APARTMENT | 5.561 | -1.100 | 0.000 | -44.033 | 0.000 | 0.000 | 3.609 | 1.454 | 12.213 | 9.230 | 0.000 | 2.471 | 12.942 | 0.000 | -1.535 | 0.000 | -0.812 | 0.000 |
| OFFICE | 0.000 | 0.000 | 4.112 | -28.828 | 0.000 | 0.000 | 1.960 | 7.396 | 9.469 | 10.403 | 0.000 | 1.640 | 0.000 | 0.000 | -2.360 | 0.000 | -0.794 | -2.996 |
| G NE APARTMENT | 5.561 | -1.101 | 0.000 | -44.168 | 0.000 | 0.000 | 3.609 | 1.454 | 12.213 | 9.119 | 0.000 | 2.471 | 13.111 | 0.000 | -1.457 | 0.000 | -0.813 | 0.000 |
| G N1 APARTMENT | 5.562 | -1.104 | 0.000 | -37.155 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 4.651 | 0.000 | 1.490 | 10.878 | 0.000 | -0.928 | 0.000 | -0.670 | 0.000 |
| G N2 APARTMENT | 5.562 | -1.104 | 0.000 | -37.162 | 0.000 | 0.000 | 3.608 | 1.454 | 12.213 | 4.650 | 0.000 | 1.490 | 10.885 | 0.000 | -0.928 | 0.000 | -0.670 | 0.000 |
| G S1 APARTMENT | 5.561 | -1.104 | 0.000 | -41.325 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 7.332 | 0.000 | 1.490 | 12.395 | 0.000 | -0.904 | 0.000 | -0.675 | 0.000 |
| G S2 APARTMENT | 5.560 | -1.104 | 0.000 | -44.722 | 0.000 | 0.000 | 3.561 | 1.454 | 12.213 | 7.294 | 0.000 | 1.490 | 15.848 | 0.000 | -0.920 | 0.000 | -0.675 | 0.000 |
| M SW APARTMENT | 11.125 | -2.200 | 0.000 | -94.380 | 0.000 | 0.000 | 7.124 | 2.908 | 24.426 | 24.034 | 0.000 | 7.085 | 24.899 | 0.000 | -2.939 | 0.000 | -2.083 | -0.000 |
| M NW APARTMENT | 11.126 | -2.185 | 0.000 | -85.994 | 0.000 | 0.000 | 7.222 | 2.908 | 24.426 | 18.758 | 0.000 | 7.085 | 21.687 | 0.000 | -2.978 | 0.000 | -2.055 | -0.000 |
| M SE APARTMENT | 11.125 | -2.201 | 0.000 | -94.717 | 0.000 | 0.000 | 7.124 | 2.908 | 24.426 | 23.883 | 0.000 | 7.085 | 25.303 | 0.000 | -2.852 | 0.000 | -2.085 | -0.000 |
| M NE APARTMENT | 11.126 | -2.188 | 0.000 | -86.310 | 0.000 | 0.000 | 7.222 | 2.908 | 24.426 | 18.542 | 0.000 | 7.085 | 22.078 | 0.000 | -2.827 | 0.000 | -2.061 | -0.000 |
| M N1 APARTMENT | 11.128 | -2.205 | 0.000 | -71.759 | 0.000 | 0.000 | 7.217 | 2.908 | 24.426 | 9.469 | 0.000 | 4.274 | 18.013 | 0.000 | -1.815 | 0.000 | -1.656 | 0.000 |
| M N2 APARTMENT | 11.128 | -2.205 | 0.000 | -71.777 | 0.000 | 0.000 | 7.217 | 2.908 | 24.426 | 9.468 | 0.000 | 4.274 | 18.032 | 0.000 | -1.815 | 0.000 | -1.656 | 0.000 |
| M S1 APARTMENT | 11.127 | -2.208 | 0.000 | -80.340 | 0.000 | 0.000 | 7.122 | 2.908 | 24.426 | 14.804 | 0.000 | 4.274 | 21.320 | 0.000 | -1.758 | 0.000 | -1.674 | 0.000 |
| M S2 APARTMENT | 11.127 | -2.208 | 0.000 | -80.356 | 0.000 | 0.000 | 7.122 | 2.908 | 24.426 | 14.804 | 0.000 | 4.274 | 21.336 | 0.000 | -1.758 | 0.000 | -1.674 | 0.000 |
| T SW APARTMENT | 5.562 | -1.003 | 0.000 | -52.075 | 0.000 | 0.000 | 3.588 | 1.454 | 12.213 | 11.795 | 0.000 | 4.664 | 16.362 | 0.000 | -1.357 | 0.000 | -1.203 | -0.000 |
| T NW APARTMENT | 5.562 | -0.975 | 0.003 | -47.712 | 0.000 | 0.000 | 3.640 | 1.454 | 12.213 | 9.186 | 0.000 | 4.664 | 14.489 | 0.000 | -1.363 | 0.000 | -1.161 | -0.000 |
| T SE APARTMENT | 5.562 | -1.007 | 0.000 | -52.270 | 0.000 | 0.000 | 3.587 | 1.454 | 12.213 | 11.725 | 0.000 | 4.664 | 16.606 | 0.000 | -1.320 | 0.000 | -1.213 | -0.000 |
| T NE APARTMENT | 5.562 | -0.982 | 0.003 | -47.884 | 0.000 | 0.000 | 3.639 | 1.454 | 12.213 | 9.089 | 0.000 | 4.664 | 14.717 | 0.000 | -1.301 | 0.000 | -1.175 | -0.000 |
| T N1 APARTMENT | 5.563 | -1.022 | 0.000 | -39.540 | 0.000 | 0.000 | 3.628 | 1.454 | 12.213 | 4.637 | 0.000 | 2.813 | 12.046 | 0.000 | -0.848 | 0.000 | -0.943 | -0.000 |
| T N2 APARTMENT | 5.563 | -1.023 | 0.000 | -39.557 | 0.000 | 0.000 | 3.628 | 1.454 | 12.213 | 4.636 | 0.000 | 2.813 | 12.064 | 0.000 | -0.848 | 0.000 | -0.944 | -0.000 |
| T S1 APARTMENT | 5.562 | -1.046 | 0.000 | -44.024 | 0.000 | 0.000 | 3.576 | 1.454 | 12.213 | 7.285 | 0.000 | 2.813 | 13.973 | 0.000 | -0.830 | 0.000 | -0.976 | -0.000 |
| T S2 APARTMENT | 5.562 | -1.046 | 0.000 | -44.041 | 0.000 | 0.000 | 3.576 | 1.454 | 12.213 | 7.284 | 0.000 | 2.813 | 13.990 | 0.000 | -0.830 | 0.000 | -0.976 | -0.000 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.191 | 11.688 | 0.000 | 1.017 | 0.000 | 0.540 | 0.000 | 0.000 | -0.159 | 0.000 | -0.172 | -18.106 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.745 | 11.688 | 3.530 | 2.864 | 0.000 | 7.620 | 0.000 | 0.000 | -0.542 | 0.000 | -4.603 | -25.303 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.367 | 23.376 | 0.000 | 2.061 | 0.000 | 0.894 | 0.000 | 0.000 | -0.341 | 0.000 | -0.293 | -36.063 |
| Total Facility | 172.438 | -33.421 | 4.117 | -1358.077 | 0.000 | 0.000 | 133.613 | 99.229 | 391.594 | 269.905 | 0.000 | 99.414 | 377.222 | 0.000 | -39.032 | 0.000 | -34.534 | -82.470 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 21-MAY-13:00 | 0.00 | 467.15 | 0.00 | -3554.63 | 0.00 | 0.00 | 83.61 | 17.36 | 388.49 | 919.21 | 0.00 | 1401.47 | 277.33 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 21-MAY-13:00 | 0.00 | 467.12 | 0.00 | -3515.52 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 865.61 | 0.00 | 1401.47 | 333.66 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 20-OCT-07:02 | 0.00 | 0.00 | 0.00 | -8254.95 | 0.00 | 0.00 | 233.74 | 582.92 | 588.62 | 255.28 | 0.00 | 0.00 | 6608.41 | 0.00 | -0.00 | 0.00 | -14.02 | 0.00 |
| G NE APARTMENT | 21-MAY-13:00 | 0.00 | 467.10 | 0.00 | -3612.77 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 750.58 | 0.00 | 1401.47 | 545.97 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 21-MAY-13:00 | 0.00 | 467.05 | 0.00 | -2620.98 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 458.47 | 0.00 | 845.33 | 402.48 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 21-MAY-13:00 | 0.00 | 467.05 | 0.00 | -2624.63 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 458.41 | 0.00 | 845.33 | 406.18 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 21-MAY-13:00 | 0.00 | 467.09 | 0.00 | -2666.46 | 0.00 | 0.00 | 83.61 | 17.36 | 388.49 | 512.19 | 0.00 | 845.33 | 352.39 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 04-SEP-17:00 | 0.00 | 531.02 | 0.00 | -2895.11 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 340.08 | 0.00 | 217.48 | 963.88 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 21-MAY-13:00 | 0.00 | 934.45 | 0.00 | -8586.18 | 0.00 | 0.00 | 167.23 | 34.72 | 776.98 | 1851.52 | 0.00 | 4022.33 | 798.95 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 21-MAY-13:00 | 0.00 | 934.42 | 0.00 | -8477.12 | 0.00 | 0.00 | 83.61 | 34.72 | 776.98 | 1743.90 | 0.00 | 4022.33 | 881.15 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 21-MAY-13:00 | 0.00 | 934.40 | 0.00 | -8819.94 | 0.00 | 0.00 | 167.23 | 34.72 | 776.98 | 1622.52 | 0.00 | 4022.33 | 1261.76 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 21-MAY-13:00 | 0.00 | 934.38 | 0.00 | -8708.46 | 0.00 | 0.00 | 83.61 | 34.72 | 776.98 | 1514.98 | 0.00 | 4022.33 | 1341.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 21-MAY-13:00 | 0.00 | 934.26 | 0.00 | -6048.79 | 0.00 | 0.00 | 83.61 | 34.72 | 776.98 | 925.37 | 0.00 | 2426.17 | 867.68 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 21-MAY-13:00 | 0.00 | 934.26 | 0.00 | -6057.37 | 0.00 | 0.00 | 83.61 | 34.72 | 776.98 | 925.26 | 0.00 | 2426.17 | 876.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 21-MAY-13:00 | 0.00 | 934.33 | 0.00 | -6158.78 | 0.00 | 0.00 | 167.23 | 34.72 | 776.98 | 1033.73 | 0.00 | 2426.17 | 785.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 21-MAY-13:00 | 0.00 | 934.33 | 0.00 | -6167.39 | 0.00 | 0.00 | 167.23 | 34.72 | 776.98 | 1033.61 | 0.00 | 2426.17 | 794.35 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 21-MAY-13:00 | 0.00 | 467.20 | 0.00 | -5728.64 | 0.00 | 0.00 | 83.61 | 17.36 | 388.49 | 899.88 | 0.00 | 2652.79 | 1219.30 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 21-MAY-13:00 | 0.00 | 467.11 | 0.00 | -5655.09 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 847.00 | 0.00 | 2652.34 | 1240.97 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 21-MAY-13:00 | 0.00 | 467.11 | 0.00 | -5890.25 | 0.00 | 0.00 | 83.60 | 17.36 | 388.49 | 785.18 | 0.00 | 2652.36 | 1496.16 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 21-MAY-13:00 | 0.00 | 467.10 | 0.00 | -5820.27 | 0.00 | 0.00 | 41.80 | 17.36 | 388.49 | 732.36 | 0.00 | 2652.38 | 1520.77 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 21-MAY-13:00 | 0.00 | 467.10 | 0.00 | -4115.44 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 449.97 | 0.00 | 1600.09 | 1150.62 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 21-MAY-13:00 | 0.00 | 467.10 | 0.00 | -4123.94 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 449.84 | 0.00 | 1600.09 | 1159.25 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 21-MAY-13:00 | 0.00 | 467.11 | 0.00 | -4185.23 | 0.00 | 0.00 | 83.61 | 17.36 | 388.49 | 503.45 | 0.00 | 1600.09 | 1125.11 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 21-MAY-13:00 | 0.00 | 467.12 | 0.00 | -4193.74 | 0.00 | 0.00 | 83.61 | 17.36 | 388.49 | 503.32 | 0.00 | 1600.09 | 1133.74 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 21-MAY-13:00 | 0.00 | 14481.39 | 0.00 | -121383.98 | 0.00 | 0.00 | 2129.88 | 2137.20 | 12305.66 | 21359.02 | 0.00 | 53042.00 | 15928.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 21-JUL-16:01 | 0.00 | 0.00 | 1116.33 | 0.00 | 0.00 | 0.00 | 0.00 | 116.58 | 294.31 | 784.28 | 0.00 | 427.55 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2739.07 |
| G NE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 15-FEB-07:53 | 29.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 179.63 | 56.42 | 382.60 | 229.14 | 0.00 | 12.47 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -889.48 |
| T NW APARTMENT | 15-FEB-07:53 | 37.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.63 | 56.42 | 382.60 | 112.79 | 0.00 | 22.86 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -766.32 |
| T SE APARTMENT | 15-FEB-07:53 | 23.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 177.99 | 56.42 | 382.60 | 489.41 | 0.00 | 2.51 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1132.36 |
| T NE APARTMENT | 15-FEB-07:53 | 31.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.24 | 56.42 | 382.60 | 373.39 | 0.00 | 13.82 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1010.62 |
| T N1 APARTMENT | 15-FEB-07:53 | 21.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.63 | 56.42 | 382.60 | 59.64 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -0.00 | -671.24 |
| T N2 APARTMENT | 15-FEB-07:53 | 21.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.62 | 56.42 | 382.60 | 59.60 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -0.06 | -671.08 |
| T S1 APARTMENT | 15-FEB-07:53 | 13.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.76 | 56.42 | 382.60 | 178.21 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -11.40 | -794.44 |
| T S2 APARTMENT | 15-FEB-07:53 | 13.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.76 | 56.42 | 382.60 | 178.17 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -11.42 | -794.37 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 21-JUL-16:01 | -86984.65 | 105527.21 | 1116.33 | -105527.21 | 0.00 | 0.00 | 1804.32 | 4289.87 | 18750.02 | 25241.33 | 0.00 | 23172.77 | 12610.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.4334 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4334 | 0.0599 | 1.0000 | Not calculated | 0.0260 | 0.0599 | ||
| SPLIT GNW | 0.4218 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4218 | 0.0615 | 1.0000 | Not calculated | 0.0260 | 0.0615 | ||
| SPLIT OFFICE | 0.4940 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4940 | 0.0771 | 1.0000 | Not calculated | 0.0381 | 0.0771 | ||
| SPLIT GNE | 0.4077 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4077 | 0.0637 | 1.0000 | Not calculated | 0.0260 | 0.0637 | ||
| SPLIT GN1 | 0.3535 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3535 | 0.0734 | 1.0000 | Not calculated | 0.0260 | 0.0734 | ||
| SPLIT GN2 | 0.3532 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3532 | 0.0735 | 1.0000 | Not calculated | 0.0260 | 0.0735 | ||
| SPLIT GS1 | 0.3660 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3660 | 0.0709 | 1.0000 | Not calculated | 0.0260 | 0.0709 | ||
| SPLIT GS2 | 0.3685 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3685 | 0.0704 | 1.0000 | Not calculated | 0.0260 | 0.0704 | ||
| SPLIT MSW | 0.9235 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9235 | 0.0562 | 1.0000 | Not calculated | 0.0519 | 0.0562 | ||
| SPLIT MNW | 0.8984 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8984 | 0.0578 | 1.0000 | Not calculated | 0.0519 | 0.0578 | ||
| SPLIT MSE | 0.8886 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8886 | 0.0584 | 1.0000 | Not calculated | 0.0519 | 0.0584 | ||
| SPLIT MNE | 0.8636 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8636 | 0.0601 | 1.0000 | Not calculated | 0.0519 | 0.0601 | ||
| SPLIT MN1 | 0.7450 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7450 | 0.0697 | 1.0000 | Not calculated | 0.0519 | 0.0697 | ||
| SPLIT MN2 | 0.7442 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7442 | 0.0697 | 1.0000 | Not calculated | 0.0519 | 0.0697 | ||
| SPLIT MS1 | 0.7723 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7723 | 0.0672 | 1.0000 | Not calculated | 0.0519 | 0.0672 | ||
| SPLIT MS2 | 0.7715 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7715 | 0.0673 | 1.0000 | Not calculated | 0.0519 | 0.0673 | ||
| SPLIT TSW | 0.5230 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5230 | 0.0496 | 1.0000 | Not calculated | 0.0260 | 0.0496 | ||
| SPLIT TNW | 0.5125 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5125 | 0.0506 | 1.0000 | Not calculated | 0.0260 | 0.0506 | ||
| SPLIT TSE | 0.4960 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4960 | 0.0523 | 1.0000 | Not calculated | 0.0260 | 0.0523 | ||
| SPLIT TNE | 0.4854 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4854 | 0.0535 | 1.0000 | Not calculated | 0.0260 | 0.0535 | ||
| SPLIT TN1 | 0.4281 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4281 | 0.0606 | 1.0000 | Not calculated | 0.0260 | 0.0606 | ||
| SPLIT TN2 | 0.4272 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4272 | 0.0608 | 1.0000 | Not calculated | 0.0260 | 0.0608 | ||
| SPLIT TS1 | 0.4393 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4393 | 0.0591 | 1.0000 | Not calculated | 0.0260 | 0.0591 | ||
| SPLIT TS2 | 0.4384 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4384 | 0.0592 | 1.0000 | Not calculated | 0.0260 | 0.0592 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.4334 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4334 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0599 | ||
| SPLIT GNW | 0.4218 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4218 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0615 | ||
| SPLIT OFFICE | 0.4940 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4940 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0771 | ||
| SPLIT GNE | 0.4077 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4077 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0637 | ||
| SPLIT GN1 | 0.3535 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3535 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0734 | ||
| SPLIT GN2 | 0.3532 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3532 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0735 | ||
| SPLIT GS1 | 0.3660 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3660 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0709 | ||
| SPLIT GS2 | 0.3685 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3685 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0704 | ||
| SPLIT MSW | 0.9235 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9235 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0562 | ||
| SPLIT MNW | 0.8984 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8984 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0578 | ||
| SPLIT MSE | 0.8886 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8886 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0584 | ||
| SPLIT MNE | 0.8636 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8636 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0601 | ||
| SPLIT MN1 | 0.7450 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7450 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0697 | ||
| SPLIT MN2 | 0.7442 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7442 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0697 | ||
| SPLIT MS1 | 0.7723 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7723 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0672 | ||
| SPLIT MS2 | 0.7715 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7715 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0673 | ||
| SPLIT TSW | 0.5230 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5230 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0496 | ||
| SPLIT TNW | 0.5125 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5125 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0506 | ||
| SPLIT TSE | 0.4960 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4960 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0523 | ||
| SPLIT TNE | 0.4854 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4854 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0535 | ||
| SPLIT TN1 | 0.4281 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4281 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0606 | ||
| SPLIT TN2 | 0.4272 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4272 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0608 | ||
| SPLIT TS1 | 0.4393 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4393 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0591 | ||
| SPLIT TS2 | 0.4384 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4384 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0592 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4334 | 0.4334 | 0.4334 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4218 | 0.4218 | 0.4218 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4940 | 0.4940 | 0.4940 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4077 | 0.4077 | 0.4077 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3535 | 0.3535 | 0.3535 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3532 | 0.3532 | 0.3532 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3660 | 0.3660 | 0.3660 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3685 | 0.3685 | 0.3685 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9235 | 0.9235 | 0.9235 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8984 | 0.8984 | 0.8984 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8886 | 0.8886 | 0.8886 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8636 | 0.8636 | 0.8636 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7450 | 0.7450 | 0.7450 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7442 | 0.7442 | 0.7442 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7723 | 0.7723 | 0.7723 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7715 | 0.7715 | 0.7715 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5230 | 0.5230 | 0.5230 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5125 | 0.5125 | 0.5125 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4960 | 0.4960 | 0.4960 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4854 | 0.4854 | 0.4854 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4281 | 0.4281 | 0.4281 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4272 | 0.4272 | 0.4272 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4393 | 0.4393 | 0.4393 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4384 | 0.4384 | 0.4384 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.4334 | 0.4334 | 0.4334 | 0.4334 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.4218 | 0.4218 | 0.4218 | 0.4218 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4940 | 0.4940 | 0.4940 | 0.4940 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.4077 | 0.4077 | 0.4077 | 0.4077 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.3535 | 0.3535 | 0.3535 | 0.3535 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.3532 | 0.3532 | 0.3532 | 0.3532 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3660 | 0.3660 | 0.3660 | 0.3660 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3685 | 0.3685 | 0.3685 | 0.3685 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.9235 | 0.9235 | 0.9235 | 0.9235 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8984 | 0.8984 | 0.8984 | 0.8984 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.8886 | 0.8886 | 0.8886 | 0.8886 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.8636 | 0.8636 | 0.8636 | 0.8636 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.7450 | 0.7450 | 0.7450 | 0.7450 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.7442 | 0.7442 | 0.7442 | 0.7442 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7723 | 0.7723 | 0.7723 | 0.7723 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.7715 | 0.7715 | 0.7715 | 0.7715 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5230 | 0.5230 | 0.5230 | 0.5230 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.5125 | 0.5125 | 0.5125 | 0.5125 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4960 | 0.4960 | 0.4960 | 0.4960 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4854 | 0.4854 | 0.4854 | 0.4854 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.4281 | 0.4281 | 0.4281 | 0.4281 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.4272 | 0.4272 | 0.4272 | 0.4272 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.4393 | 0.4393 | 0.4393 | 0.4393 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.4384 | 0.4384 | 0.4384 | 0.4384 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4334 | 0.4334 | 0.4334 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4218 | 0.4218 | 0.4218 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4940 | 0.4940 | 0.4940 | No | 0.0381 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4077 | 0.4077 | 0.4077 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3535 | 0.3535 | 0.3535 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3532 | 0.3532 | 0.3532 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3660 | 0.3660 | 0.3660 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3685 | 0.3685 | 0.3685 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9235 | 0.9235 | 0.9235 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8984 | 0.8984 | 0.8984 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8886 | 0.8886 | 0.8886 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8636 | 0.8636 | 0.8636 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7450 | 0.7450 | 0.7450 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7442 | 0.7442 | 0.7442 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7723 | 0.7723 | 0.7723 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7715 | 0.7715 | 0.7715 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5230 | 0.5230 | 0.5230 | No | 0.0260 | 0.6307 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5125 | 0.5125 | 0.5125 | No | 0.0260 | 0.7640 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4960 | 0.4960 | 0.4960 | No | 0.0260 | 0.6327 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4854 | 0.4854 | 0.4854 | No | 0.0260 | 0.7668 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4281 | 0.4281 | 0.4281 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4272 | 0.4272 | 0.4272 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4393 | 0.4393 | 0.4393 | No | 0.0260 | 0.9644 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4384 | 0.4384 | 0.4384 | No | 0.0260 | 0.9645 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.4334 | 0.4334 | 0.4334 | 0.4334 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.4218 | 0.4218 | 0.4218 | 0.4218 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4940 | 0.4940 | 0.4940 | 0.4940 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.4077 | 0.4077 | 0.4077 | 0.4077 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.3535 | 0.3535 | 0.3535 | 0.3535 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.3532 | 0.3532 | 0.3532 | 0.3532 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3660 | 0.3660 | 0.3660 | 0.3660 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3685 | 0.3685 | 0.3685 | 0.3685 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.9235 | 0.9235 | 0.9235 | 0.9235 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8984 | 0.8984 | 0.8984 | 0.8984 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.8886 | 0.8886 | 0.8886 | 0.8886 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.8636 | 0.8636 | 0.8636 | 0.8636 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.7450 | 0.7450 | 0.7450 | 0.7450 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.7442 | 0.7442 | 0.7442 | 0.7442 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7723 | 0.7723 | 0.7723 | 0.7723 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.7715 | 0.7715 | 0.7715 | 0.7715 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5230 | 0.5230 | 0.5230 | 0.5230 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.5125 | 0.5125 | 0.5125 | 0.5125 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4960 | 0.4960 | 0.4960 | 0.4960 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4854 | 0.4854 | 0.4854 | 0.4854 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.4281 | 0.4281 | 0.4281 | 0.4281 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.4272 | 0.4272 | 0.4272 | 0.4272 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.4393 | 0.4393 | 0.4393 | 0.4393 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.4384 | 0.4384 | 0.4384 | 0.4384 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Dubai Intl AP - ARE IWEC2 WMO#=411940 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.17 |
| Number of hours not met | 0.17 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 0.01 | 524.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 526.04 | 50379.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 50.10 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 181.18 | 12556.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 330.81 | 37007.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1646.02 |
| Natural Gas | 0.00 | 0.01 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1646.03 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 167.82 |
| Fans (All) | 57.80 |
| Service Water Heating | 105.54 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 525.11 |
| Subtotal | 525.11 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 0.00 |
| Subtotal | 0.00 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 6.03 |
| Space Heating | 0.00 |
| Space Cooling | 31.96 |
| Fans (All) | 11.01 |
| Service Water Heating | 20.10 |
| Receptacle Equipment | 27.86 |
| Miscellaneous | 3.04 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 2972.50 | 4747.33 | 1040.17 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 2991.00 | 4169.17 | 1599.83 | 0.00 | 0.00 |
| G CORRIDOR | 2807.67 | 3564.50 | 2314.67 | 73.17 | 0.00 |
| M CORRIDOR | 1147.50 | 7519.17 | 93.33 | 0.00 | 0.00 |
| Min | 1147.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 7519.17 | 2314.67 | 73.17 | 0.00 |
| Average | 7829.58 | 740.75 | 186.96 | 2.71 | 0.00 |
| Sum | 211398.67 | 20000.17 | 5048.00 | 73.17 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6990.67 | 9.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 8146.17 | 10770.50 | 4078.33 | 0.00 | 0.00 |
| G CORRIDOR | 7055.50 | 8858.33 | 6899.50 | 181.67 | 0.00 |
| M CORRIDOR | 3007.33 | 19745.17 | 242.50 | 0.00 | 0.00 |
| Min | 3007.33 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 11830.00 | 19745.17 | 6899.50 | 181.67 | 0.00 |
| Average | 10457.40 | 1458.64 | 415.57 | 6.73 | 0.00 |
| Sum | 282349.67 | 39383.33 | 11220.33 | 181.67 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 7396.50 | 1363.50 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 7299.33 | 1460.67 | 0.00 | 0.00 | 0.00 |
| OFFICE | 2694.67 | 5618.33 | 447.00 | 0.00 | 0.00 |
| G NE APARTMENT | 7276.33 | 1483.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 7067.33 | 1692.67 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 7067.50 | 1692.50 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 7227.00 | 1533.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 7445.17 | 1314.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 6936.00 | 1824.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 6771.67 | 1988.33 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 6924.67 | 1835.33 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 6755.00 | 2005.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 6669.67 | 2090.33 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 6669.83 | 2090.17 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 6822.17 | 1937.83 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 6822.00 | 1938.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 6687.83 | 2072.17 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 6574.50 | 2185.50 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 6675.33 | 2084.67 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 6554.83 | 2205.17 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 6592.00 | 2168.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 6591.50 | 2168.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 6753.83 | 2006.17 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 6738.33 | 2021.67 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 28.33 | 5950.83 | 2780.83 | 0.00 | 0.00 |
| G CORRIDOR | 1424.17 | 5198.33 | 2036.00 | 101.33 | 0.17 |
| M CORRIDOR | 0.00 | 6163.67 | 2596.33 | 0.00 | 0.00 |
| Min | 0.00 | 1314.83 | 0.00 | 0.00 | 0.00 |
| Max | 7445.17 | 6163.67 | 2780.83 | 101.33 | 0.17 |
| Average | 6017.24 | 2447.88 | 291.12 | 3.75 | 0.01 |
| Sum | 162465.50 | 66092.83 | 7860.17 | 101.33 | 0.17 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 9698.00 | 2132.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8454.67 | 2130.33 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6168.67 | 831.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8356.67 | 2228.33 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8108.33 | 2476.67 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8107.17 | 2477.83 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 9419.17 | 2410.83 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 9759.83 | 2070.17 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 9000.67 | 2829.33 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 7707.00 | 2878.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8909.33 | 2920.67 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 7593.17 | 2991.83 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 7562.50 | 3022.50 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 7559.83 | 3025.17 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8803.17 | 3026.83 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8801.67 | 3028.33 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8502.67 | 3327.33 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 7280.17 | 3304.83 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8396.17 | 3433.83 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 7137.50 | 3447.50 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 7306.67 | 3278.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 7301.33 | 3283.67 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8599.83 | 3230.17 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8572.17 | 3257.83 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 60.67 | 15302.00 | 7632.33 | 0.00 | 0.00 |
| G CORRIDOR | 2603.50 | 13685.00 | 6449.00 | 257.17 | 0.33 |
| M CORRIDOR | 0.00 | 15673.17 | 7321.83 | 0.00 | 0.00 |
| Min | 0.00 | 831.33 | 0.00 | 0.00 | 0.00 |
| Max | 9759.83 | 15673.17 | 7632.33 | 257.17 | 0.33 |
| Average | 7398.91 | 4137.18 | 792.71 | 9.52 | 0.01 |
| Sum | 199770.50 | 111703.83 | 21403.17 | 257.17 | 0.33 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:22
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0B
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY ARE_DUBAI_DUBAIINTL
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 19.235 |
| February | 20.749 |
| March | 23.120 |
| April | 26.486 |
| May | 31.365 |
| June | 32.970 |
| July | 35.085 |
| August | 35.314 |
| September | 32.488 |
| October | 29.531 |
| November | 25.532 |
| December | 21.128 |
| Annual Sum or Average | 27.790 |
| Minimum of Months | 19.235 |
| Maximum of Months | 35.314 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.205089E+10 | 1597.67 | 28-JAN-14:40 | 26.67 | 16.87 | 0.129203E+09 | 70.37 | 01-JAN-03:49 | 26.67 | 16.87 |
| February | 0.193013E+10 | 1982.51 | 05-FEB-15:10 | 32.00 | 19.31 | 0.115024E+09 | 70.36 | 22-FEB-04:40 | 14.13 | 12.91 |
| March | 0.233318E+10 | 2161.86 | 01-MAR-15:30 | 36.05 | 18.62 | 0.123866E+09 | 70.37 | 07-MAR-05:10 | 14.83 | 12.07 |
| April | 0.274225E+10 | 2207.97 | 28-APR-15:10 | 34.88 | 22.93 | 0.123958E+09 | 70.31 | 27-APR-04:30 | 34.88 | 22.93 |
| May | 0.385040E+10 | 3087.05 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.420444E+10 | 2749.46 | 09-JUN-16:40 | 41.03 | 25.07 | 0.120422E+09 | 70.27 | 03-JUN-09:09 | 41.03 | 25.07 |
| July | 0.496064E+10 | 2906.38 | 21-JUL-17:04 | 42.00 | 23.59 | 0.129276E+09 | 70.27 | 04-JUL-08:39 | 42.00 | 23.59 |
| August | 0.542771E+10 | 2992.95 | 10-AUG-16:02 | 41.33 | 30.18 | 0.123963E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.491584E+10 | 2993.02 | 04-SEP-16:40 | 40.23 | 23.29 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.467847E+10 | 2868.84 | 09-OCT-16:01 | 36.67 | 19.14 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.375298E+10 | 2467.08 | 05-NOV-15:20 | 31.80 | 21.10 | 0.123963E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.264586E+10 | 1907.34 | 03-DEC-14:30 | 27.00 | 20.88 | 0.129271E+09 | 70.31 | 09-DEC-21:30 | 23.30 | 16.80 |
| Annual Sum or Average | 0.434928E+11 | 0.149615E+10 | ||||||||
| Minimum of Months | 0.193013E+10 | 1597.67 | 26.67 | 16.87 | 0.115024E+09 | 70.27 | 14.13 | 12.07 | ||
| Maximum of Months | 0.542771E+10 | 3087.05 | 42.00 | 30.18 | 0.129276E+09 | 70.37 | 42.00 | 25.07 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141742E+10 | 1188.94 | 29-JAN-17:10 | 24.83 | 20.08 | 0.128317E+09 | 70.36 | 07-JAN-04:10 | 24.83 | 20.08 |
| February | 0.143613E+10 | 1495.67 | 06-FEB-15:30 | 31.95 | 17.43 | 0.116007E+09 | 70.37 | 12-FEB-03:20 | 14.83 | 12.03 |
| March | 0.196188E+10 | 1933.07 | 27-MAR-16:01 | 34.83 | 18.74 | 0.128578E+09 | 70.38 | 08-MAR-03:09 | 34.83 | 18.74 |
| April | 0.254989E+10 | 2117.99 | 28-APR-16:07 | 34.25 | 21.30 | 0.124613E+09 | 70.31 | 27-APR-04:30 | 34.25 | 21.30 |
| May | 0.386009E+10 | 3047.94 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.430912E+10 | 2834.81 | 09-JUN-17:00 | 41.00 | 24.84 | 0.124621E+09 | 70.27 | 27-JUN-04:30 | 28.40 | 26.45 |
| July | 0.499827E+10 | 2945.10 | 21-JUL-17:00 | 42.00 | 23.53 | 0.128775E+09 | 70.27 | 21-JUL-22:30 | 37.90 | 20.91 |
| August | 0.532720E+10 | 2937.64 | 10-AUG-16:02 | 41.33 | 30.18 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.456902E+10 | 2795.45 | 04-SEP-17:00 | 40.00 | 22.93 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.408283E+10 | 2456.64 | 19-OCT-16:06 | 34.92 | 17.28 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.306302E+10 | 1968.41 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124621E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.199768E+10 | 1373.08 | 01-DEC-16:10 | 26.75 | 18.64 | 0.128745E+09 | 70.31 | 24-DEC-06:40 | 16.33 | 16.33 |
| Annual Sum or Average | 0.395725E+11 | 0.151522E+10 | ||||||||
| Minimum of Months | 0.141742E+10 | 1188.94 | 24.83 | 17.28 | 0.116007E+09 | 70.27 | 14.83 | 12.03 | ||
| Maximum of Months | 0.532720E+10 | 3047.94 | 42.00 | 30.18 | 0.128775E+09 | 70.38 | 38.00 | 26.45 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.136329E+10 | 7556.64 | 17-JAN-09:02 | 20.47 | 14.85 | 70310905.60 | 217.47 | 30-JAN-08:09 | 20.33 | 17.75 |
| February | 0.135003E+10 | 7145.56 | 27-FEB-08:62 | 18.50 | 16.35 | 66852849.18 | 217.47 | 09-FEB-08:09 | 18.50 | 16.35 |
| March | 0.172576E+10 | 8028.46 | 14-MAR-07:02 | 23.83 | 16.52 | 81058318.89 | 224.04 | 02-MAR-08:09 | 23.83 | 16.52 |
| April | 0.180040E+10 | 8147.97 | 24-APR-07:02 | 22.75 | 14.78 | 70635079.55 | 217.47 | 03-APR-07:10 | 22.75 | 14.78 |
| May | 0.263692E+10 | 7955.64 | 08-MAY-07:02 | 27.75 | 16.25 | 77770745.65 | 217.47 | 30-MAY-07:10 | 27.83 | 25.31 |
| June | 0.285038E+10 | 7754.95 | 02-JUN-07:02 | 29.67 | 18.04 | 77775499.74 | 217.47 | 09-JUN-07:10 | 33.42 | 27.70 |
| July | 0.306710E+10 | 7797.98 | 03-JUL-07:02 | 29.67 | 17.12 | 70716039.29 | 217.54 | 18-JUL-07:10 | 30.33 | 27.88 |
| August | 0.369935E+10 | 6606.61 | 07-AUG-07:02 | 32.83 | 22.82 | 81328144.06 | 217.47 | 22-AUG-07:10 | 31.58 | 28.58 |
| September | 0.313915E+10 | 7239.45 | 26-SEP-07:02 | 27.00 | 17.98 | 70710656.28 | 217.47 | 05-SEP-07:10 | 27.00 | 17.98 |
| October | 0.307740E+10 | 8254.81 | 20-OCT-07:02 | 23.25 | 15.43 | 74240481.92 | 217.47 | 18-OCT-07:10 | 23.25 | 15.43 |
| November | 0.243668E+10 | 7961.95 | 22-NOV-08:62 | 18.33 | 15.12 | 70700049.47 | 217.47 | 28-NOV-08:09 | 19.57 | 16.18 |
| December | 0.168269E+10 | 8129.06 | 27-DEC-08:62 | 21.00 | 15.40 | 70530561.37 | 217.47 | 12-DEC-08:09 | 21.00 | 15.40 |
| Annual Sum or Average | 0.288291E+11 | 0.882629E+09 | ||||||||
| Minimum of Months | 0.135003E+10 | 6606.61 | 18.33 | 14.78 | 66852849.18 | 217.47 | 18.50 | 14.78 | ||
| Maximum of Months | 0.369935E+10 | 8254.81 | 32.83 | 22.82 | 81328144.06 | 224.04 | 33.42 | 28.58 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.143009E+10 | 1114.37 | 29-JAN-12:00 | 27.00 | 18.66 | 0.128322E+09 | 70.38 | 21-JAN-02:39 | 27.00 | 18.66 |
| February | 0.143506E+10 | 1385.64 | 06-FEB-15:10 | 32.32 | 17.34 | 0.116022E+09 | 70.36 | 12-FEB-02:39 | 14.93 | 12.08 |
| March | 0.193902E+10 | 1795.97 | 27-MAR-13:00 | 36.00 | 19.77 | 0.128566E+09 | 70.37 | 08-MAR-02:09 | 36.00 | 19.77 |
| April | 0.257775E+10 | 2147.61 | 28-APR-13:00 | 36.70 | 22.98 | 0.124612E+09 | 70.31 | 27-APR-04:30 | 36.70 | 22.98 |
| May | 0.390191E+10 | 3145.18 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.431911E+10 | 2615.02 | 09-JUN-17:00 | 41.00 | 24.84 | 0.124621E+09 | 70.27 | 27-JUN-03:00 | 28.80 | 27.13 |
| July | 0.501390E+10 | 2795.13 | 21-JUL-17:00 | 42.00 | 23.53 | 0.128775E+09 | 70.27 | 21-JUL-22:30 | 37.90 | 20.91 |
| August | 0.534646E+10 | 2886.38 | 05-AUG-11:00 | 43.00 | 25.25 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.458181E+10 | 2621.87 | 04-SEP-17:00 | 40.00 | 22.93 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.410357E+10 | 2283.60 | 09-OCT-16:01 | 36.67 | 19.14 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.306924E+10 | 1838.59 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124621E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.198951E+10 | 1305.13 | 10-DEC-13:00 | 29.80 | 19.30 | 0.128750E+09 | 70.31 | 09-DEC-21:30 | 29.80 | 19.30 |
| Annual Sum or Average | 0.397074E+11 | 0.151524E+10 | ||||||||
| Minimum of Months | 0.143009E+10 | 1114.37 | 27.00 | 17.34 | 0.116022E+09 | 70.27 | 14.93 | 12.08 | ||
| Maximum of Months | 0.534646E+10 | 3145.18 | 43.00 | 25.74 | 0.128775E+09 | 70.38 | 38.00 | 27.13 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.140850E+10 | 937.41 | 29-JAN-17:10 | 24.83 | 20.08 | 0.128714E+09 | 70.38 | 03-JAN-05:19 | 24.83 | 20.08 |
| February | 0.138673E+10 | 1104.73 | 06-FEB-16:10 | 30.50 | 18.50 | 0.116268E+09 | 70.37 | 13-FEB-02:30 | 13.90 | 11.19 |
| March | 0.179177E+10 | 1383.26 | 27-MAR-16:04 | 34.83 | 18.74 | 0.128713E+09 | 70.31 | 13-MAR-05:00 | 34.83 | 18.74 |
| April | 0.220876E+10 | 1547.89 | 28-APR-18:00 | 34.30 | 21.50 | 0.124621E+09 | 70.31 | 27-APR-04:30 | 34.30 | 21.50 |
| May | 0.313935E+10 | 2153.60 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.343212E+10 | 1998.47 | 09-JUN-17:03 | 40.83 | 24.93 | 0.124621E+09 | 70.27 | 27-JUN-03:49 | 28.90 | 27.25 |
| July | 0.392137E+10 | 2117.67 | 21-JUL-17:06 | 42.00 | 23.59 | 0.128775E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.412198E+10 | 2087.39 | 05-AUG-17:14 | 40.67 | 26.29 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.358759E+10 | 1997.23 | 04-SEP-17:03 | 39.67 | 23.33 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.328412E+10 | 1747.91 | 09-OCT-16:40 | 36.27 | 20.22 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.257274E+10 | 1452.41 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124621E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.184067E+10 | 1079.63 | 10-DEC-17:10 | 26.88 | 21.40 | 0.128770E+09 | 70.32 | 21-DEC-06:49 | 16.00 | 14.14 |
| Annual Sum or Average | 0.326957E+11 | 0.151605E+10 | ||||||||
| Minimum of Months | 0.138673E+10 | 937.41 | 24.83 | 18.50 | 0.116268E+09 | 70.27 | 13.90 | 11.19 | ||
| Maximum of Months | 0.412198E+10 | 2153.60 | 42.00 | 26.29 | 0.128775E+09 | 70.38 | 38.00 | 27.25 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.140947E+10 | 936.45 | 29-JAN-17:10 | 24.83 | 20.08 | 0.128714E+09 | 70.38 | 01-JAN-03:09 | 24.83 | 20.08 |
| February | 0.138710E+10 | 1103.14 | 05-FEB-17:05 | 31.00 | 18.53 | 0.116268E+09 | 70.37 | 13-FEB-02:30 | 13.90 | 11.19 |
| March | 0.179089E+10 | 1381.57 | 27-MAR-16:04 | 34.83 | 18.74 | 0.128713E+09 | 70.30 | 13-MAR-05:00 | 34.83 | 18.74 |
| April | 0.221002E+10 | 1546.18 | 28-APR-18:00 | 34.30 | 21.50 | 0.124621E+09 | 70.31 | 27-APR-04:30 | 34.30 | 21.50 |
| May | 0.314118E+10 | 2157.24 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.343256E+10 | 1994.82 | 09-JUN-17:03 | 40.83 | 24.93 | 0.124621E+09 | 70.27 | 27-JUN-03:00 | 28.80 | 27.13 |
| July | 0.392196E+10 | 2115.02 | 21-JUL-17:06 | 42.00 | 23.59 | 0.128775E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.412274E+10 | 2085.41 | 05-AUG-17:14 | 40.67 | 26.29 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.358814E+10 | 1994.60 | 04-SEP-17:03 | 39.67 | 23.33 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.328506E+10 | 1745.66 | 09-OCT-16:40 | 36.27 | 20.22 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.257315E+10 | 1450.68 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124621E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.184055E+10 | 1079.19 | 10-DEC-17:10 | 26.88 | 21.40 | 0.128770E+09 | 70.31 | 21-DEC-06:49 | 16.00 | 14.14 |
| Annual Sum or Average | 0.327028E+11 | 0.151605E+10 | ||||||||
| Minimum of Months | 0.138710E+10 | 936.45 | 24.83 | 18.53 | 0.116268E+09 | 70.27 | 13.90 | 11.19 | ||
| Maximum of Months | 0.412274E+10 | 2157.24 | 42.00 | 26.29 | 0.128775E+09 | 70.38 | 38.00 | 27.13 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.207842E+10 | 1394.84 | 28-JAN-13:50 | 27.88 | 13.04 | 0.129275E+09 | 70.35 | 05-JAN-07:10 | 27.88 | 13.04 |
| February | 0.190787E+10 | 1633.99 | 05-FEB-14:00 | 31.60 | 19.33 | 0.115107E+09 | 70.31 | 19-FEB-09:00 | 24.00 | 17.55 |
| March | 0.218507E+10 | 1612.73 | 27-MAR-16:01 | 34.83 | 18.74 | 0.123941E+09 | 70.36 | 11-MAR-07:40 | 34.83 | 18.74 |
| April | 0.241698E+10 | 1648.92 | 28-APR-13:00 | 36.70 | 22.98 | 0.123963E+09 | 70.31 | 27-APR-04:30 | 36.70 | 22.98 |
| May | 0.314378E+10 | 2199.07 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.333934E+10 | 1916.63 | 09-JUN-17:03 | 40.83 | 24.93 | 0.120422E+09 | 70.27 | 03-JUN-09:20 | 40.83 | 24.93 |
| July | 0.389720E+10 | 2087.40 | 21-JUL-17:06 | 42.00 | 23.59 | 0.129276E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.423723E+10 | 2117.99 | 10-AUG-16:02 | 41.33 | 30.18 | 0.123963E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.395247E+10 | 2182.85 | 04-SEP-17:00 | 40.00 | 22.93 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.390317E+10 | 2175.54 | 09-OCT-16:03 | 36.67 | 19.14 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.328924E+10 | 1952.50 | 05-NOV-15:10 | 31.90 | 20.93 | 0.123963E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.251616E+10 | 1632.73 | 03-DEC-13:50 | 27.47 | 20.47 | 0.129276E+09 | 70.31 | 09-DEC-21:30 | 23.30 | 16.80 |
| Annual Sum or Average | 0.368669E+11 | 0.149639E+10 | ||||||||
| Minimum of Months | 0.190787E+10 | 1394.84 | 27.47 | 13.04 | 0.115107E+09 | 70.27 | 23.23 | 13.04 | ||
| Maximum of Months | 0.423723E+10 | 2199.07 | 42.00 | 30.18 | 0.129276E+09 | 70.36 | 40.83 | 24.93 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.226290E+10 | 1480.80 | 28-JAN-13:50 | 27.88 | 13.04 | 0.129276E+09 | 70.34 | 01-JAN-09:39 | 27.88 | 13.04 |
| February | 0.208011E+10 | 1759.72 | 05-FEB-14:00 | 31.60 | 19.33 | 0.115109E+09 | 70.31 | 19-FEB-09:00 | 24.00 | 17.55 |
| March | 0.239276E+10 | 1703.81 | 27-MAR-16:01 | 34.83 | 18.74 | 0.123953E+09 | 70.33 | 11-MAR-06:30 | 34.83 | 18.74 |
| April | 0.267657E+10 | 1737.05 | 28-APR-13:00 | 36.70 | 22.98 | 0.123963E+09 | 70.31 | 27-APR-04:30 | 36.70 | 22.98 |
| May | 0.346992E+10 | 2359.28 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.365724E+10 | 2004.22 | 09-JUN-17:03 | 40.83 | 24.93 | 0.120422E+09 | 70.27 | 15-JUN-18:49 | 35.17 | 21.79 |
| July | 0.424795E+10 | 2180.65 | 30-JUL-15:10 | 40.45 | 27.73 | 0.129276E+09 | 70.27 | 04-JUL-08:39 | 40.45 | 27.73 |
| August | 0.458204E+10 | 2268.51 | 13-AUG-16:02 | 38.67 | 26.10 | 0.123963E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.429129E+10 | 2364.32 | 04-SEP-17:00 | 40.00 | 22.93 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.425341E+10 | 2357.91 | 09-OCT-16:03 | 36.67 | 19.14 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.360077E+10 | 2121.45 | 05-NOV-15:10 | 31.90 | 20.93 | 0.123963E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.275067E+10 | 1775.99 | 03-DEC-13:50 | 27.47 | 20.47 | 0.129276E+09 | 70.31 | 09-DEC-21:30 | 23.30 | 16.80 |
| Annual Sum or Average | 0.402656E+11 | 0.149640E+10 | ||||||||
| Minimum of Months | 0.208011E+10 | 1480.80 | 27.47 | 13.04 | 0.115109E+09 | 70.27 | 23.23 | 13.04 | ||
| Maximum of Months | 0.458204E+10 | 2364.32 | 40.83 | 27.73 | 0.129276E+09 | 70.34 | 40.45 | 27.73 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.188750E+10 | 1746.42 | 28-JAN-14:40 | 26.67 | 16.87 | 0.128614E+09 | 70.31 | 13-JAN-04:00 | 26.67 | 16.87 |
| February | 0.196939E+10 | 2294.66 | 05-FEB-15:10 | 32.00 | 19.31 | 0.114829E+09 | 70.31 | 15-FEB-04:10 | 15.17 | 11.65 |
| March | 0.265612E+10 | 2603.67 | 01-MAR-15:30 | 36.05 | 18.62 | 0.123871E+09 | 70.31 | 13-MAR-06:40 | 16.60 | 13.59 |
| April | 0.317254E+10 | 2640.65 | 28-APR-15:10 | 34.88 | 22.93 | 0.123955E+09 | 70.31 | 27-APR-04:30 | 34.88 | 22.93 |
| May | 0.420428E+10 | 3825.35 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 15-MAY-06:40 | 38.00 | 22.80 |
| June | 0.442707E+10 | 3142.39 | 09-JUN-16:03 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-09:20 | 41.08 | 25.41 |
| July | 0.499694E+10 | 3135.38 | 21-JUL-16:30 | 42.05 | 24.24 | 0.129276E+09 | 70.27 | 21-JUL-22:30 | 37.90 | 20.91 |
| August | 0.516781E+10 | 3132.61 | 10-AUG-16:02 | 41.33 | 30.18 | 0.123963E+09 | 70.27 | 09-AUG-03:00 | 41.33 | 30.18 |
| September | 0.455428E+10 | 3048.66 | 04-SEP-16:30 | 40.35 | 23.48 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.416533E+10 | 2974.23 | 19-OCT-15:10 | 35.85 | 17.88 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.324080E+10 | 2492.36 | 05-NOV-15:20 | 31.80 | 21.10 | 0.123957E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.228505E+10 | 1961.89 | 03-DEC-14:30 | 27.00 | 20.88 | 0.129099E+09 | 70.32 | 28-DEC-06:00 | 14.70 | 12.29 |
| Annual Sum or Average | 0.427271E+11 | 0.149519E+10 | ||||||||
| Minimum of Months | 0.188750E+10 | 1746.42 | 26.67 | 16.87 | 0.114829E+09 | 70.27 | 14.70 | 11.65 | ||
| Maximum of Months | 0.516781E+10 | 3825.35 | 42.05 | 30.18 | 0.129276E+09 | 70.32 | 41.33 | 30.18 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.123201E+10 | 1215.53 | 29-JAN-17:10 | 24.83 | 20.08 | 0.127078E+09 | 70.32 | 16-JAN-00:10 | 24.83 | 20.08 |
| February | 0.144566E+10 | 1691.96 | 06-FEB-15:30 | 31.95 | 17.43 | 0.115677E+09 | 70.31 | 22-FEB-01:39 | 15.40 | 13.92 |
| March | 0.225720E+10 | 2295.31 | 27-MAR-16:04 | 34.83 | 18.74 | 0.128635E+09 | 70.32 | 07-MAR-03:09 | 34.83 | 18.74 |
| April | 0.296108E+10 | 2526.21 | 28-APR-15:10 | 34.88 | 22.93 | 0.124613E+09 | 70.31 | 27-APR-04:30 | 34.88 | 22.93 |
| May | 0.420309E+10 | 3770.80 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.452205E+10 | 3224.95 | 09-JUN-16:30 | 41.05 | 25.18 | 0.124621E+09 | 70.27 | 27-JUN-04:30 | 28.40 | 26.45 |
| July | 0.502011E+10 | 3165.97 | 21-JUL-16:30 | 42.05 | 24.24 | 0.128775E+09 | 70.27 | 21-JUL-22:19 | 37.87 | 20.37 |
| August | 0.504905E+10 | 3071.53 | 10-AUG-16:10 | 41.33 | 30.18 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.418156E+10 | 2815.11 | 04-SEP-16:40 | 40.23 | 23.29 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.353392E+10 | 2515.49 | 19-OCT-16:04 | 34.92 | 17.28 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.251608E+10 | 1893.90 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124608E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.160448E+10 | 1277.49 | 01-DEC-16:10 | 26.75 | 18.64 | 0.128331E+09 | 70.31 | 22-DEC-05:30 | 16.00 | 14.14 |
| Annual Sum or Average | 0.385263E+11 | 0.151329E+10 | ||||||||
| Minimum of Months | 0.123201E+10 | 1215.53 | 24.83 | 17.28 | 0.115677E+09 | 70.27 | 15.40 | 13.92 | ||
| Maximum of Months | 0.504905E+10 | 3770.80 | 42.05 | 30.18 | 0.128775E+09 | 70.32 | 38.00 | 26.45 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.190539E+10 | 1726.93 | 28-JAN-13:50 | 27.88 | 13.04 | 0.128616E+09 | 70.32 | 07-JAN-03:39 | 27.88 | 13.04 |
| February | 0.196988E+10 | 2240.00 | 05-FEB-14:00 | 31.60 | 19.33 | 0.114835E+09 | 70.30 | 19-FEB-09:00 | 24.00 | 17.55 |
| March | 0.263344E+10 | 2487.56 | 27-MAR-13:00 | 36.00 | 19.77 | 0.123875E+09 | 70.31 | 25-MAR-05:40 | 36.00 | 19.77 |
| April | 0.320582E+10 | 2724.27 | 28-APR-13:00 | 36.70 | 22.98 | 0.123954E+09 | 70.31 | 27-APR-04:30 | 36.70 | 22.98 |
| May | 0.425060E+10 | 3942.22 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.443979E+10 | 2874.62 | 09-JUN-16:03 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 15-JUN-18:40 | 35.33 | 21.61 |
| July | 0.501542E+10 | 2950.57 | 30-JUL-15:10 | 40.45 | 27.73 | 0.129276E+09 | 70.27 | 21-JUL-22:30 | 40.45 | 27.73 |
| August | 0.518965E+10 | 3095.39 | 16-AUG-12:00 | 46.00 | 25.38 | 0.123963E+09 | 70.27 | 08-AUG-21:40 | 46.00 | 25.38 |
| September | 0.456991E+10 | 2817.55 | 04-SEP-14:00 | 41.00 | 25.17 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.418924E+10 | 2773.30 | 19-OCT-15:10 | 35.85 | 17.88 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.324922E+10 | 2351.22 | 05-NOV-13:30 | 33.20 | 21.19 | 0.123957E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.227793E+10 | 1907.03 | 03-DEC-13:40 | 27.93 | 20.01 | 0.129103E+09 | 70.32 | 30-DEC-05:49 | 13.33 | 10.96 |
| Annual Sum or Average | 0.428963E+11 | 0.149520E+10 | ||||||||
| Minimum of Months | 0.190539E+10 | 1726.93 | 27.88 | 13.04 | 0.114835E+09 | 70.27 | 13.33 | 10.96 | ||
| Maximum of Months | 0.518965E+10 | 3942.22 | 46.00 | 27.73 | 0.129276E+09 | 70.32 | 46.00 | 27.73 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.124462E+10 | 1143.58 | 29-JAN-12:00 | 27.00 | 18.66 | 0.127135E+09 | 70.32 | 01-JAN-23:00 | 27.00 | 18.66 |
| February | 0.144470E+10 | 1543.42 | 06-FEB-15:10 | 32.32 | 17.34 | 0.115700E+09 | 70.30 | 20-FEB-21:10 | 17.02 | 15.74 |
| March | 0.223434E+10 | 2145.04 | 27-MAR-13:00 | 36.00 | 19.77 | 0.128632E+09 | 70.32 | 08-MAR-06:49 | 36.00 | 19.77 |
| April | 0.299417E+10 | 2574.53 | 28-APR-13:00 | 36.70 | 22.98 | 0.124612E+09 | 70.31 | 27-APR-04:30 | 36.70 | 22.98 |
| May | 0.424949E+10 | 3886.46 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.453488E+10 | 2944.65 | 09-JUN-16:15 | 41.07 | 25.29 | 0.124621E+09 | 70.27 | 27-JUN-04:19 | 28.53 | 26.68 |
| July | 0.503864E+10 | 2966.29 | 21-JUL-17:00 | 42.00 | 23.53 | 0.128775E+09 | 70.27 | 21-JUL-22:19 | 37.87 | 20.37 |
| August | 0.507093E+10 | 3009.62 | 05-AUG-11:00 | 43.00 | 25.25 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.419707E+10 | 2574.94 | 04-SEP-16:50 | 40.12 | 23.11 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.355748E+10 | 2278.93 | 19-OCT-16:04 | 34.92 | 17.28 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.252401E+10 | 1731.14 | 01-NOV-15:10 | 32.00 | 26.07 | 0.124610E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.159585E+10 | 1248.68 | 10-DEC-13:00 | 29.80 | 19.30 | 0.128347E+09 | 70.32 | 29-DEC-04:19 | 16.20 | 13.71 |
| Annual Sum or Average | 0.386862E+11 | 0.151338E+10 | ||||||||
| Minimum of Months | 0.124462E+10 | 1143.58 | 27.00 | 17.28 | 0.115700E+09 | 70.27 | 16.20 | 13.71 | ||
| Maximum of Months | 0.507093E+10 | 3886.46 | 43.00 | 26.07 | 0.128775E+09 | 70.32 | 38.00 | 26.68 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.130770E+10 | 941.92 | 29-JAN-17:10 | 24.83 | 20.08 | 0.128505E+09 | 70.32 | 04-JAN-06:49 | 24.83 | 20.08 |
| February | 0.141105E+10 | 1202.69 | 05-FEB-17:05 | 31.00 | 18.53 | 0.116234E+09 | 70.32 | 01-FEB-05:49 | 31.00 | 18.53 |
| March | 0.199584E+10 | 1560.95 | 27-MAR-16:04 | 34.83 | 18.74 | 0.128737E+09 | 70.30 | 23-MAR-02:39 | 34.83 | 18.74 |
| April | 0.245381E+10 | 1743.03 | 28-APR-13:30 | 35.85 | 23.12 | 0.124621E+09 | 70.31 | 27-APR-04:30 | 35.85 | 23.12 |
| May | 0.328178E+10 | 2556.86 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.347230E+10 | 2135.66 | 09-JUN-16:30 | 41.05 | 25.18 | 0.124621E+09 | 70.27 | 27-JUN-03:00 | 28.80 | 27.13 |
| July | 0.381504E+10 | 2151.43 | 21-JUL-17:04 | 42.00 | 23.59 | 0.128775E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.381444E+10 | 2056.13 | 10-AUG-16:02 | 41.33 | 30.18 | 0.128775E+09 | 70.27 | 08-AUG-21:30 | 41.33 | 30.18 |
| September | 0.323812E+10 | 1897.92 | 04-SEP-17:00 | 40.00 | 22.93 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.285419E+10 | 1697.35 | 19-OCT-16:04 | 34.92 | 17.28 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.218382E+10 | 1356.86 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124620E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.158959E+10 | 1017.49 | 10-DEC-17:10 | 26.88 | 21.40 | 0.128698E+09 | 70.31 | 09-DEC-21:30 | 26.88 | 21.40 |
| Annual Sum or Average | 0.314177E+11 | 0.151576E+10 | ||||||||
| Minimum of Months | 0.130770E+10 | 941.92 | 24.83 | 17.28 | 0.116234E+09 | 70.27 | 23.23 | 16.65 | ||
| Maximum of Months | 0.381504E+10 | 2556.86 | 42.00 | 30.18 | 0.128775E+09 | 70.32 | 41.33 | 30.18 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.130943E+10 | 940.76 | 29-JAN-17:10 | 24.83 | 20.08 | 0.128504E+09 | 70.32 | 27-JAN-06:49 | 24.83 | 20.08 |
| February | 0.141164E+10 | 1201.40 | 05-FEB-17:05 | 31.00 | 18.53 | 0.116234E+09 | 70.31 | 01-FEB-05:49 | 31.00 | 18.53 |
| March | 0.199523E+10 | 1558.97 | 27-MAR-16:04 | 34.83 | 18.74 | 0.128737E+09 | 70.30 | 23-MAR-02:39 | 34.83 | 18.74 |
| April | 0.245510E+10 | 1747.14 | 28-APR-13:30 | 35.85 | 23.12 | 0.124621E+09 | 70.31 | 27-APR-04:30 | 35.85 | 23.12 |
| May | 0.328352E+10 | 2561.15 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.347282E+10 | 2132.17 | 09-JUN-16:30 | 41.05 | 25.18 | 0.124621E+09 | 70.27 | 27-JUN-04:19 | 28.53 | 26.68 |
| July | 0.381569E+10 | 2148.72 | 21-JUL-17:04 | 42.00 | 23.59 | 0.128775E+09 | 70.27 | 21-JUL-22:30 | 37.90 | 20.91 |
| August | 0.381522E+10 | 2053.79 | 10-AUG-16:02 | 41.33 | 30.18 | 0.128775E+09 | 70.27 | 09-AUG-05:10 | 41.33 | 30.18 |
| September | 0.323875E+10 | 1894.87 | 04-SEP-17:00 | 40.00 | 22.93 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.285521E+10 | 1694.75 | 19-OCT-16:04 | 34.92 | 17.28 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.218435E+10 | 1354.94 | 01-NOV-16:03 | 32.00 | 25.74 | 0.124620E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.158976E+10 | 1017.12 | 10-DEC-17:10 | 26.88 | 21.40 | 0.128698E+09 | 70.32 | 31-DEC-06:49 | 13.17 | 10.14 |
| Annual Sum or Average | 0.314267E+11 | 0.151576E+10 | ||||||||
| Minimum of Months | 0.130943E+10 | 940.76 | 24.83 | 17.28 | 0.116234E+09 | 70.27 | 13.17 | 10.14 | ||
| Maximum of Months | 0.381569E+10 | 2561.15 | 42.00 | 30.18 | 0.128775E+09 | 70.32 | 41.33 | 30.18 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.199970E+10 | 1541.08 | 28-JAN-13:50 | 27.88 | 13.04 | 0.129235E+09 | 70.32 | 20-JAN-02:30 | 27.88 | 13.04 |
| February | 0.195047E+10 | 1850.71 | 05-FEB-14:00 | 31.60 | 19.33 | 0.115100E+09 | 70.31 | 12-FEB-09:09 | 16.57 | 13.29 |
| March | 0.240071E+10 | 1865.23 | 01-MAR-15:10 | 36.02 | 18.60 | 0.123939E+09 | 70.31 | 08-MAR-18:40 | 23.40 | 15.94 |
| April | 0.266683E+10 | 1886.56 | 28-APR-13:20 | 36.13 | 23.08 | 0.123963E+09 | 70.31 | 27-APR-04:30 | 36.13 | 23.08 |
| May | 0.328311E+10 | 2611.86 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.337687E+10 | 2057.82 | 09-JUN-16:07 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-09:09 | 41.08 | 25.41 |
| July | 0.379153E+10 | 2116.59 | 21-JUL-17:04 | 42.00 | 23.59 | 0.129276E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.393334E+10 | 2116.73 | 10-AUG-16:02 | 41.33 | 30.18 | 0.123963E+09 | 70.27 | 08-AUG-06:00 | 41.33 | 30.18 |
| September | 0.361248E+10 | 2119.71 | 04-SEP-16:13 | 40.47 | 23.66 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.349007E+10 | 2152.25 | 09-OCT-15:10 | 36.97 | 20.38 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.291671E+10 | 1935.48 | 05-NOV-15:10 | 31.90 | 20.93 | 0.123963E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.228844E+10 | 1678.11 | 03-DEC-13:40 | 27.93 | 20.01 | 0.129258E+09 | 70.31 | 23-DEC-06:40 | 16.33 | 15.51 |
| Annual Sum or Average | 0.357102E+11 | 0.149632E+10 | ||||||||
| Minimum of Months | 0.195047E+10 | 1541.08 | 27.88 | 13.04 | 0.115100E+09 | 70.27 | 16.33 | 13.04 | ||
| Maximum of Months | 0.393334E+10 | 2611.86 | 42.00 | 30.18 | 0.129276E+09 | 70.32 | 41.33 | 30.18 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.200081E+10 | 1544.39 | 28-JAN-13:50 | 27.88 | 13.04 | 0.129234E+09 | 70.32 | 01-JAN-07:49 | 27.88 | 13.04 |
| February | 0.195088E+10 | 1853.48 | 05-FEB-14:00 | 31.60 | 19.33 | 0.115100E+09 | 70.31 | 04-FEB-07:40 | 31.60 | 19.33 |
| March | 0.240010E+10 | 1863.11 | 01-MAR-15:10 | 36.02 | 18.60 | 0.123939E+09 | 70.31 | 08-MAR-18:40 | 23.40 | 15.94 |
| April | 0.266811E+10 | 1890.96 | 28-APR-13:20 | 36.13 | 23.08 | 0.123963E+09 | 70.31 | 27-APR-04:30 | 36.13 | 23.08 |
| May | 0.328485E+10 | 2616.16 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.337740E+10 | 2054.86 | 09-JUN-16:07 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-09:09 | 41.08 | 25.41 |
| July | 0.379219E+10 | 2113.90 | 21-JUL-17:04 | 42.00 | 23.59 | 0.129276E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.393412E+10 | 2114.39 | 10-AUG-16:02 | 41.33 | 30.18 | 0.123963E+09 | 70.27 | 09-AUG-05:19 | 41.33 | 30.18 |
| September | 0.361311E+10 | 2117.17 | 04-SEP-16:13 | 40.47 | 23.66 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.349105E+10 | 2151.43 | 09-OCT-15:10 | 36.97 | 20.38 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.291718E+10 | 1934.70 | 05-NOV-15:10 | 31.90 | 20.93 | 0.123963E+09 | 70.31 | 18-NOV-00:49 | 23.42 | 17.53 |
| December | 0.228845E+10 | 1679.81 | 03-DEC-13:40 | 27.93 | 20.01 | 0.129258E+09 | 70.31 | 23-DEC-06:40 | 16.33 | 15.51 |
| Annual Sum or Average | 0.357183E+11 | 0.149632E+10 | ||||||||
| Minimum of Months | 0.195088E+10 | 1544.39 | 27.88 | 13.04 | 0.115100E+09 | 70.27 | 16.33 | 13.04 | ||
| Maximum of Months | 0.393412E+10 | 2616.16 | 42.00 | 30.18 | 0.129276E+09 | 70.32 | 41.33 | 30.18 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.150330E+10 | 2172.50 | 22-JAN-15:30 | 26.00 | 16.72 | 0.118127E+09 | 70.37 | 22-JAN-00:30 | 26.00 | 16.72 |
| February | 0.174861E+10 | 3026.95 | 05-FEB-15:00 | 32.00 | 19.39 | 0.108830E+09 | 70.37 | 12-FEB-22:40 | 16.53 | 12.89 |
| March | 0.262128E+10 | 3624.86 | 01-MAR-15:30 | 36.05 | 18.62 | 0.121245E+09 | 70.36 | 04-MAR-01:39 | 18.07 | 14.53 |
| April | 0.344566E+10 | 3681.30 | 28-APR-13:50 | 35.28 | 23.19 | 0.123596E+09 | 70.32 | 13-APR-03:39 | 35.28 | 23.19 |
| May | 0.498322E+10 | 5260.77 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 15-MAY-06:40 | 38.00 | 22.80 |
| June | 0.534650E+10 | 4373.65 | 09-JUN-16:02 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-09:20 | 41.08 | 25.41 |
| July | 0.618441E+10 | 4366.83 | 21-JUL-16:20 | 42.07 | 24.48 | 0.129276E+09 | 70.27 | 21-JUL-22:49 | 37.97 | 21.95 |
| August | 0.636528E+10 | 4378.22 | 10-AUG-16:01 | 41.33 | 30.18 | 0.123963E+09 | 70.27 | 15-AUG-17:49 | 39.00 | 23.49 |
| September | 0.538287E+10 | 4179.22 | 04-SEP-16:10 | 40.58 | 23.84 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.465038E+10 | 4001.35 | 19-OCT-15:10 | 35.85 | 17.88 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.328681E+10 | 3281.62 | 05-NOV-15:10 | 31.90 | 20.93 | 0.123498E+09 | 70.34 | 28-NOV-04:49 | 19.12 | 16.07 |
| December | 0.199659E+10 | 2538.30 | 03-DEC-14:20 | 27.00 | 20.88 | 0.123609E+09 | 70.37 | 30-DEC-23:49 | 17.17 | 12.22 |
| Annual Sum or Average | 0.475149E+11 | 0.146977E+10 | ||||||||
| Minimum of Months | 0.150330E+10 | 2172.50 | 26.00 | 16.72 | 0.108830E+09 | 70.27 | 16.53 | 12.22 | ||
| Maximum of Months | 0.636528E+10 | 5260.77 | 42.07 | 30.18 | 0.129276E+09 | 70.37 | 41.08 | 25.41 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.870905E+09 | 1474.40 | 29-JAN-16:10 | 25.83 | 20.06 | 0.115304E+09 | 70.36 | 05-JAN-21:00 | 25.83 | 20.06 |
| February | 0.121846E+10 | 2296.31 | 06-FEB-15:30 | 31.95 | 17.43 | 0.108970E+09 | 70.35 | 28-FEB-02:30 | 20.00 | 17.43 |
| March | 0.219763E+10 | 3137.66 | 27-MAR-16:01 | 34.83 | 18.74 | 0.125862E+09 | 70.37 | 07-MAR-23:00 | 34.83 | 18.74 |
| April | 0.321294E+10 | 3483.09 | 28-APR-14:10 | 35.00 | 23.22 | 0.124276E+09 | 70.34 | 16-APR-03:00 | 35.00 | 23.22 |
| May | 0.498077E+10 | 5187.27 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.544901E+10 | 4457.22 | 09-JUN-16:15 | 41.07 | 25.29 | 0.124621E+09 | 70.27 | 27-JUN-03:39 | 29.00 | 27.37 |
| July | 0.620594E+10 | 4396.40 | 21-JUL-16:30 | 42.05 | 24.24 | 0.128775E+09 | 70.27 | 21-JUL-22:49 | 37.97 | 21.95 |
| August | 0.622781E+10 | 4283.45 | 10-AUG-16:01 | 41.33 | 30.18 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.497200E+10 | 3874.18 | 04-SEP-16:30 | 40.35 | 23.48 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.396405E+10 | 3367.74 | 19-OCT-15:20 | 35.70 | 17.74 | 0.128775E+09 | 70.30 | 21-OCT-02:39 | 23.33 | 16.05 |
| November | 0.251505E+10 | 2491.69 | 01-NOV-15:10 | 32.00 | 26.07 | 0.124030E+09 | 70.36 | 23-NOV-02:20 | 19.67 | 15.55 |
| December | 0.130643E+10 | 1627.65 | 10-DEC-13:50 | 29.13 | 19.95 | 0.121935E+09 | 70.35 | 14-DEC-00:20 | 18.87 | 16.38 |
| Annual Sum or Average | 0.431210E+11 | 0.148472E+10 | ||||||||
| Minimum of Months | 0.870905E+09 | 1474.40 | 25.83 | 17.43 | 0.108970E+09 | 70.27 | 18.87 | 15.55 | ||
| Maximum of Months | 0.622781E+10 | 5187.27 | 42.05 | 30.18 | 0.128775E+09 | 70.37 | 38.00 | 27.37 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.151080E+10 | 2098.31 | 28-JAN-14:20 | 27.33 | 15.13 | 0.118255E+09 | 70.35 | 31-JAN-02:09 | 20.00 | 15.15 |
| February | 0.174351E+10 | 2947.83 | 05-FEB-14:00 | 31.60 | 19.33 | 0.108817E+09 | 70.36 | 10-FEB-19:30 | 19.10 | 12.85 |
| March | 0.259701E+10 | 3466.35 | 27-MAR-13:00 | 36.00 | 19.77 | 0.121237E+09 | 70.36 | 05-MAR-21:49 | 36.00 | 19.77 |
| April | 0.348720E+10 | 3859.82 | 28-APR-13:00 | 36.70 | 22.98 | 0.123597E+09 | 70.35 | 14-APR-05:10 | 36.70 | 22.98 |
| May | 0.503898E+10 | 5422.41 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.536675E+10 | 3968.09 | 09-JUN-16:02 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-08:00 | 41.08 | 25.41 |
| July | 0.620924E+10 | 4207.76 | 30-JUL-14:00 | 44.00 | 24.47 | 0.129276E+09 | 70.27 | 21-JUL-22:49 | 44.00 | 24.47 |
| August | 0.639379E+10 | 4389.71 | 16-AUG-12:00 | 46.00 | 25.38 | 0.123963E+09 | 70.27 | 15-AUG-17:49 | 46.00 | 25.38 |
| September | 0.540512E+10 | 3972.35 | 04-SEP-14:00 | 41.00 | 25.17 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.468036E+10 | 3741.98 | 09-OCT-14:00 | 37.00 | 20.40 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.329809E+10 | 3158.53 | 05-NOV-13:30 | 33.20 | 21.19 | 0.123518E+09 | 70.33 | 26-NOV-02:30 | 18.50 | 15.15 |
| December | 0.198410E+10 | 2491.06 | 03-DEC-13:40 | 27.93 | 20.01 | 0.123667E+09 | 70.36 | 16-DEC-22:10 | 20.08 | 15.03 |
| Annual Sum or Average | 0.477150E+11 | 0.146996E+10 | ||||||||
| Minimum of Months | 0.151080E+10 | 2098.31 | 27.33 | 15.13 | 0.108817E+09 | 70.27 | 18.50 | 12.85 | ||
| Maximum of Months | 0.639379E+10 | 5422.41 | 46.00 | 25.41 | 0.129276E+09 | 70.36 | 46.00 | 25.41 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.869867E+09 | 1406.94 | 29-JAN-12:00 | 27.00 | 18.66 | 0.115385E+09 | 70.37 | 14-JAN-21:49 | 27.00 | 18.66 |
| February | 0.120934E+10 | 2079.22 | 06-FEB-15:10 | 32.32 | 17.34 | 0.108985E+09 | 70.35 | 28-FEB-01:39 | 19.93 | 17.17 |
| March | 0.217245E+10 | 3025.61 | 27-MAR-13:00 | 36.00 | 19.77 | 0.125840E+09 | 70.36 | 09-MAR-03:09 | 36.00 | 19.77 |
| April | 0.325423E+10 | 3645.65 | 28-APR-13:00 | 36.70 | 22.98 | 0.124272E+09 | 70.35 | 14-APR-04:00 | 36.70 | 22.98 |
| May | 0.503679E+10 | 5352.40 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.546954E+10 | 4043.66 | 09-JUN-16:02 | 41.08 | 25.41 | 0.124621E+09 | 70.27 | 27-JUN-04:10 | 28.67 | 26.90 |
| July | 0.623093E+10 | 4124.00 | 21-JUL-14:00 | 42.00 | 27.65 | 0.128775E+09 | 70.27 | 21-JUL-22:49 | 37.97 | 21.95 |
| August | 0.625644E+10 | 4201.80 | 16-AUG-12:00 | 46.00 | 25.38 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.499405E+10 | 3541.03 | 05-SEP-14:10 | 39.83 | 25.07 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.399325E+10 | 3063.22 | 19-OCT-15:10 | 35.85 | 17.88 | 0.128775E+09 | 70.30 | 21-OCT-02:39 | 23.33 | 16.05 |
| November | 0.252432E+10 | 2336.20 | 01-NOV-14:10 | 32.83 | 26.22 | 0.124053E+09 | 70.33 | 29-NOV-06:40 | 20.73 | 19.46 |
| December | 0.128896E+10 | 1643.65 | 10-DEC-13:30 | 29.40 | 19.70 | 0.121985E+09 | 70.35 | 18-DEC-23:10 | 18.83 | 14.31 |
| Annual Sum or Average | 0.433002E+11 | 0.148486E+10 | ||||||||
| Minimum of Months | 0.869867E+09 | 1406.94 | 27.00 | 17.34 | 0.108985E+09 | 70.27 | 18.83 | 14.31 | ||
| Maximum of Months | 0.625644E+10 | 5352.40 | 46.00 | 27.65 | 0.128775E+09 | 70.37 | 38.00 | 26.90 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.854465E+09 | 1095.98 | 23-JAN-14:00 | 28.00 | 16.55 | 0.119572E+09 | 70.37 | 15-JAN-21:30 | 28.00 | 16.55 |
| February | 0.111711E+10 | 1633.44 | 06-FEB-15:10 | 32.32 | 17.34 | 0.111830E+09 | 70.36 | 10-FEB-06:10 | 19.82 | 12.70 |
| March | 0.188772E+10 | 2180.80 | 27-MAR-16:01 | 34.83 | 18.74 | 0.127059E+09 | 70.36 | 10-MAR-03:30 | 34.83 | 18.74 |
| April | 0.265814E+10 | 2564.61 | 28-APR-13:00 | 36.70 | 22.98 | 0.124472E+09 | 70.35 | 05-APR-02:09 | 36.70 | 22.98 |
| May | 0.396498E+10 | 3647.79 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.428635E+10 | 3070.43 | 09-JUN-16:17 | 41.07 | 25.29 | 0.124621E+09 | 70.27 | 27-JUN-04:19 | 28.53 | 26.68 |
| July | 0.486023E+10 | 3108.42 | 21-JUL-16:30 | 42.05 | 24.24 | 0.128775E+09 | 70.27 | 21-JUL-22:40 | 37.93 | 21.43 |
| August | 0.485071E+10 | 2997.39 | 04-AUG-13:00 | 44.50 | 24.79 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.392795E+10 | 2702.16 | 04-SEP-16:17 | 40.47 | 23.66 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.322000E+10 | 2293.24 | 19-OCT-15:10 | 35.85 | 17.88 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.214864E+10 | 1783.48 | 01-NOV-15:10 | 32.00 | 26.07 | 0.124357E+09 | 70.36 | 23-NOV-03:39 | 19.07 | 15.35 |
| December | 0.122308E+10 | 1302.99 | 10-DEC-13:40 | 29.27 | 19.82 | 0.124712E+09 | 70.38 | 30-DEC-23:30 | 17.50 | 12.50 |
| Annual Sum or Average | 0.349993E+11 | 0.149634E+10 | ||||||||
| Minimum of Months | 0.854465E+09 | 1095.98 | 28.00 | 16.55 | 0.111830E+09 | 70.27 | 17.50 | 12.50 | ||
| Maximum of Months | 0.486023E+10 | 3647.79 | 44.50 | 26.07 | 0.128775E+09 | 70.38 | 38.00 | 26.68 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.857536E+09 | 1096.56 | 23-JAN-14:00 | 28.00 | 16.55 | 0.119562E+09 | 70.37 | 15-JAN-21:30 | 28.00 | 16.55 |
| February | 0.111875E+10 | 1630.76 | 06-FEB-15:10 | 32.32 | 17.34 | 0.111821E+09 | 70.37 | 10-FEB-23:19 | 19.00 | 12.97 |
| March | 0.188785E+10 | 2174.96 | 27-MAR-16:01 | 34.83 | 18.74 | 0.127051E+09 | 70.35 | 10-MAR-03:30 | 34.83 | 18.74 |
| April | 0.266021E+10 | 2574.37 | 28-APR-13:00 | 36.70 | 22.98 | 0.124471E+09 | 70.34 | 05-APR-02:09 | 36.70 | 22.98 |
| May | 0.396740E+10 | 3656.30 | 21-MAY-13:00 | 38.00 | 22.80 | 0.128775E+09 | 70.30 | 04-MAY-03:49 | 38.00 | 22.80 |
| June | 0.428732E+10 | 3061.95 | 09-JUN-16:17 | 41.07 | 25.29 | 0.124621E+09 | 70.27 | 27-JUN-04:19 | 28.53 | 26.68 |
| July | 0.486127E+10 | 3102.50 | 21-JUL-16:30 | 42.05 | 24.24 | 0.128775E+09 | 70.28 | 04-JUL-04:49 | 42.05 | 24.24 |
| August | 0.485187E+10 | 3006.34 | 04-AUG-13:00 | 44.50 | 24.79 | 0.128775E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.392902E+10 | 2694.98 | 04-SEP-16:17 | 40.47 | 23.66 | 0.124621E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.322158E+10 | 2289.33 | 19-OCT-15:10 | 35.85 | 17.88 | 0.128775E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.214985E+10 | 1781.25 | 01-NOV-15:10 | 32.00 | 26.07 | 0.124356E+09 | 70.35 | 23-NOV-03:39 | 19.07 | 15.35 |
| December | 0.122436E+10 | 1305.60 | 10-DEC-13:40 | 29.27 | 19.82 | 0.124704E+09 | 70.37 | 30-DEC-23:30 | 17.50 | 12.50 |
| Annual Sum or Average | 0.350170E+11 | 0.149631E+10 | ||||||||
| Minimum of Months | 0.857536E+09 | 1096.56 | 28.00 | 16.55 | 0.111821E+09 | 70.27 | 17.50 | 12.50 | ||
| Maximum of Months | 0.486127E+10 | 3656.30 | 44.50 | 26.07 | 0.128775E+09 | 70.37 | 42.05 | 26.68 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.152029E+10 | 1857.27 | 28-JAN-14:30 | 27.00 | 16.03 | 0.122366E+09 | 70.37 | 19-JAN-21:49 | 27.00 | 16.03 |
| February | 0.166746E+10 | 2458.21 | 05-FEB-14:00 | 31.60 | 19.33 | 0.111556E+09 | 70.37 | 11-FEB-02:30 | 19.50 | 14.26 |
| March | 0.231962E+10 | 2647.87 | 01-MAR-15:10 | 36.02 | 18.60 | 0.122419E+09 | 70.36 | 07-MAR-00:49 | 16.98 | 13.13 |
| April | 0.289314E+10 | 2776.69 | 28-APR-13:00 | 36.70 | 22.98 | 0.123803E+09 | 70.34 | 04-APR-05:49 | 36.70 | 22.98 |
| May | 0.396721E+10 | 3717.61 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 15-MAY-06:40 | 38.00 | 22.80 |
| June | 0.418285E+10 | 2989.74 | 09-JUN-16:02 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-09:30 | 41.08 | 25.41 |
| July | 0.483819E+10 | 3118.76 | 30-JUL-15:10 | 40.45 | 27.73 | 0.129276E+09 | 70.27 | 21-JUL-22:40 | 40.45 | 27.73 |
| August | 0.498887E+10 | 3135.37 | 16-AUG-12:00 | 46.00 | 25.38 | 0.123963E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.434213E+10 | 3058.10 | 04-SEP-14:00 | 41.00 | 25.17 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.391346E+10 | 3004.76 | 09-OCT-14:10 | 37.00 | 20.45 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.293326E+10 | 2622.12 | 05-NOV-13:30 | 33.20 | 21.19 | 0.123778E+09 | 70.35 | 22-NOV-03:09 | 17.98 | 15.02 |
| December | 0.194091E+10 | 2201.15 | 03-DEC-13:40 | 27.93 | 20.01 | 0.126213E+09 | 70.38 | 31-DEC-00:40 | 16.93 | 11.94 |
| Annual Sum or Average | 0.395074E+11 | 0.148100E+10 | ||||||||
| Minimum of Months | 0.152029E+10 | 1857.27 | 27.00 | 16.03 | 0.111556E+09 | 70.27 | 16.93 | 11.94 | ||
| Maximum of Months | 0.498887E+10 | 3717.61 | 46.00 | 27.73 | 0.129276E+09 | 70.38 | 41.08 | 27.73 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.152319E+10 | 1862.71 | 28-JAN-14:20 | 27.33 | 15.13 | 0.122357E+09 | 70.36 | 31-JAN-04:19 | 18.67 | 15.12 |
| February | 0.166887E+10 | 2463.42 | 05-FEB-14:00 | 31.60 | 19.33 | 0.111547E+09 | 70.36 | 23-FEB-00:00 | 17.90 | 15.93 |
| March | 0.231971E+10 | 2643.60 | 01-MAR-15:10 | 36.02 | 18.60 | 0.122413E+09 | 70.35 | 07-MAR-00:49 | 16.98 | 13.13 |
| April | 0.289521E+10 | 2786.47 | 28-APR-13:00 | 36.70 | 22.98 | 0.123802E+09 | 70.33 | 04-APR-05:49 | 36.70 | 22.98 |
| May | 0.396964E+10 | 3726.12 | 21-MAY-13:00 | 38.00 | 22.80 | 0.125734E+09 | 70.30 | 15-MAY-06:40 | 38.00 | 22.80 |
| June | 0.418383E+10 | 2981.87 | 09-JUN-16:02 | 41.08 | 25.41 | 0.120422E+09 | 70.27 | 03-JUN-09:09 | 41.08 | 25.41 |
| July | 0.483924E+10 | 3120.16 | 30-JUL-14:10 | 43.50 | 24.98 | 0.129276E+09 | 70.27 | 21-JUL-22:40 | 43.50 | 24.98 |
| August | 0.499003E+10 | 3146.29 | 16-AUG-12:00 | 46.00 | 25.38 | 0.123963E+09 | 70.27 | 19-AUG-05:30 | 33.50 | 23.83 |
| September | 0.434320E+10 | 3061.33 | 04-SEP-14:00 | 41.00 | 25.17 | 0.123963E+09 | 70.29 | 25-SEP-04:49 | 23.23 | 22.44 |
| October | 0.391498E+10 | 3006.32 | 09-OCT-14:10 | 37.00 | 20.45 | 0.127505E+09 | 70.30 | 21-OCT-01:10 | 23.58 | 16.65 |
| November | 0.293434E+10 | 2626.52 | 05-NOV-13:30 | 33.20 | 21.19 | 0.123778E+09 | 70.36 | 27-NOV-04:00 | 18.00 | 16.14 |
| December | 0.194195E+10 | 2204.74 | 03-DEC-13:40 | 27.93 | 20.01 | 0.126206E+09 | 70.37 | 01-DEC-03:39 | 27.93 | 20.01 |
| Annual Sum or Average | 0.395242E+11 | 0.148097E+10 | ||||||||
| Minimum of Months | 0.152319E+10 | 1862.71 | 27.33 | 15.13 | 0.111547E+09 | 70.27 | 16.98 | 13.13 | ||
| Maximum of Months | 0.499003E+10 | 3726.12 | 46.00 | 25.41 | 0.129276E+09 | 70.37 | 43.50 | 25.41 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 | 12.84 | 0.234006E+09 | 152.04 | 29-JAN-21:10 | 23.30 | 19.38 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 | 14.59 | 0.223763E+09 | 159.71 | 05-FEB-21:10 | 24.95 | 19.71 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 | 18.46 | 0.264964E+09 | 171.91 | 27-MAR-20:10 | 30.67 | 16.51 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 | 20.11 | 0.274628E+09 | 178.79 | 28-APR-20:10 | 32.67 | 18.30 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 | 23.56 | 0.307434E+09 | 192.04 | 31-MAY-20:10 | 39.87 | 21.29 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 | 23.24 | 0.305048E+09 | 192.75 | 09-JUN-20:10 | 36.83 | 25.99 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 | 27.02 | 0.325615E+09 | 197.06 | 21-JUL-20:10 | 40.83 | 20.42 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 | 28.28 | 0.326799E+09 | 199.15 | 16-AUG-20:10 | 37.67 | 28.77 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 | 25.04 | 0.302364E+09 | 188.16 | 04-SEP-20:10 | 35.27 | 26.62 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 | 26.77 | 0.297131E+09 | 177.39 | 05-OCT-20:10 | 32.83 | 25.03 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 | 21.17 | 0.265948E+09 | 168.08 | 01-NOV-20:10 | 30.00 | 23.04 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 | 15.63 | 0.249205E+09 | 154.07 | 10-DEC-21:10 | 24.80 | 18.57 |
| Annual Sum or Average | 0.00 | 0.337691E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 15.70 | 12.84 | 0.223763E+09 | 152.04 | 23.30 | 16.51 | ||
| Maximum of Months | 0.00 | 0.00 | 33.23 | 28.28 | 0.326799E+09 | 199.15 | 40.83 | 28.77 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 | 12.84 | 0.251948E+09 | 162.22 | 29-JAN-22:49 | 22.13 | 19.32 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 | 14.59 | 0.236470E+09 | 186.80 | 05-FEB-18:10 | 30.53 | 19.22 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 | 18.46 | 0.279060E+09 | 217.79 | 27-MAR-17:10 | 33.85 | 18.25 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 | 20.11 | 0.297488E+09 | 223.07 | 29-APR-17:10 | 33.67 | 22.47 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 | 23.56 | 0.349952E+09 | 266.29 | 30-MAY-17:10 | 38.33 | 25.85 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 | 23.24 | 0.353860E+09 | 286.83 | 09-JUN-17:10 | 40.83 | 24.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 | 27.02 | 0.384044E+09 | 300.42 | 21-JUL-17:10 | 42.00 | 23.59 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 | 28.28 | 0.390189E+09 | 295.59 | 05-AUG-17:10 | 40.83 | 26.31 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 | 25.04 | 0.357093E+09 | 286.49 | 04-SEP-17:10 | 39.67 | 23.33 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 | 26.77 | 0.347482E+09 | 246.02 | 09-OCT-17:10 | 35.67 | 21.15 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 | 21.17 | 0.303204E+09 | 202.65 | 01-NOV-17:10 | 31.83 | 24.76 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 | 15.63 | 0.271837E+09 | 168.06 | 10-DEC-22:49 | 23.13 | 18.97 |
| Annual Sum or Average | 0.00 | 0.382263E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 15.70 | 12.84 | 0.236470E+09 | 162.22 | 22.13 | 18.25 | ||
| Maximum of Months | 0.00 | 0.00 | 33.23 | 28.28 | 0.390189E+09 | 300.42 | 42.00 | 26.31 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 | 12.84 | 0.266446E+09 | 152.74 | 29-JAN-21:10 | 23.30 | 19.38 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 | 14.59 | 0.244514E+09 | 155.89 | 05-FEB-21:10 | 24.95 | 19.71 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 | 18.46 | 0.277165E+09 | 161.78 | 27-MAR-20:10 | 30.67 | 16.51 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 | 20.11 | 0.275780E+09 | 164.68 | 28-APR-20:10 | 32.67 | 18.30 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 | 23.56 | 0.295860E+09 | 169.63 | 31-MAY-20:10 | 39.87 | 21.29 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 | 23.24 | 0.290195E+09 | 171.06 | 09-JUN-20:10 | 36.83 | 25.99 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 | 27.02 | 0.303861E+09 | 172.34 | 21-JUL-20:10 | 40.83 | 20.42 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 | 28.28 | 0.304807E+09 | 174.42 | 16-AUG-20:10 | 37.67 | 28.77 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 | 25.04 | 0.289123E+09 | 169.95 | 04-SEP-20:10 | 35.27 | 26.62 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 | 26.77 | 0.292167E+09 | 165.05 | 05-OCT-20:10 | 32.83 | 25.03 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 | 21.17 | 0.273229E+09 | 160.61 | 01-NOV-20:10 | 30.00 | 23.04 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 | 15.63 | 0.271234E+09 | 153.40 | 05-DEC-21:10 | 24.67 | 21.79 |
| Annual Sum or Average | 0.00 | 0.338438E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 15.70 | 12.84 | 0.244514E+09 | 152.74 | 23.30 | 16.51 | ||
| Maximum of Months | 0.00 | 0.00 | 33.23 | 28.28 | 0.304807E+09 | 174.42 | 40.83 | 28.77 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.320456E+09 | 562.85 | 23-JAN-08:04 | 18.50 |
| February | 0.350914E+09 | 616.14 | 24-FEB-09:05 | 22.00 |
| March | 0.521826E+09 | 780.22 | 27-MAR-17:25 | 33.55 |
| April | 0.612187E+09 | 822.43 | 27-APR-16:13 | 35.13 |
| May | 0.502891E+09 | 936.72 | 23-MAY-06:05 | 29.95 |
| June | 0.378933E+09 | 1087.35 | 09-JUN-16:01 | 41.08 |
| July | 0.150629E+09 | 1116.30 | 21-JUL-16:01 | 42.08 |
| August | 86141175.36 | 1061.16 | 10-AUG-16:01 | 41.33 |
| September | 0.172249E+09 | 922.13 | 01-SEP-06:05 | 30.00 |
| October | 0.270663E+09 | 823.04 | 05-OCT-17:12 | 35.67 |
| November | 0.371775E+09 | 747.12 | 20-NOV-07:05 | 25.25 |
| December | 0.372733E+09 | 632.72 | 01-DEC-08:04 | 19.83 |
| Annual Sum or Average | 0.411140E+10 | |||
| Minimum of Months | 86141175.36 | 562.85 | 18.50 | |
| Maximum of Months | 0.612187E+09 | 1116.30 | 42.08 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 15038.82 | 29.22 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 15038.82 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 15038.82 | 29.22 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 37720.18 | 23.98 | 16-JAN-11:00 | 24.00 |
| February | 29652.38 | 37.02 | 15-FEB-07:53 | 23.20 |
| March | 10517.94 | 22.77 | 17-MAR-08:55 | 24.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 22985.14 | 19.93 | 31-DEC-11:00 | 24.00 |
| Annual Sum or Average | 100875.64 | |||
| Minimum of Months | 0.00 | 0.00 | 22.05 | |
| Maximum of Months | 37720.18 | 37.02 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 11294.19 | 23.42 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 11294.19 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 11294.19 | 23.42 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 16078.81 | 31.14 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 16078.81 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 16078.81 | 31.14 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 3391.15 | 5.65 | 16-JAN-10:50 | 23.50 |
| February | 10987.39 | 21.94 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 14378.54 | |||
| Minimum of Months | 0.00 | 0.00 | 21.12 | |
| Maximum of Months | 10987.39 | 21.94 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 2813.37 | 4.69 | 16-JAN-10:50 | 23.50 |
| February | 10946.11 | 21.90 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 13759.48 | |||
| Minimum of Months | 0.00 | 0.00 | 21.12 | |
| Maximum of Months | 10946.11 | 21.90 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 5981.50 | 13.85 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 5981.50 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 5981.50 | 13.85 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 5959.84 | 13.84 | 15-FEB-07:53 | 23.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 5959.84 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 5959.84 | 13.84 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 15.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 17.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 22.85 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 22.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 26.90 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 32.60 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 31.72 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 33.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 31.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 28.98 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 27.12 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 21.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 15.70 | |
| Maximum of Months | 0.00 | 0.00 | 33.23 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2701613.58 | 0.115994E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19449278.36 | 97733262.89 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64366523.84 | 46126016.63 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140389E+09 | 15734183.44 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295872E+09 | 816827.83 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376731E+09 | 24291.98 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450669E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464091E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.334011E+09 | 50570.43 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212724E+09 | 831946.70 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94966221.45 | 15314524.34 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15117176.05 | 71512179.87 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247109E+10 | 0.364137E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2701613.58 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464091E+09 | 0.115994E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2701619.94 | 0.115559E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19449289.13 | 97475933.36 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64366544.36 | 46054161.74 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140389E+09 | 15730880.14 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295872E+09 | 816827.68 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376731E+09 | 24291.97 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450669E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464091E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.334011E+09 | 50570.46 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212724E+09 | 831947.06 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94966221.57 | 15314520.44 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15117185.05 | 71485696.47 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247109E+10 | 0.363344E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2701619.94 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464091E+09 | 0.115559E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 976057.02 | 0.183454E+09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11917953.21 | 0.171351E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 45536257.94 | 0.112160E+09 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83359436.36 | 58409469.12 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199622E+09 | 14239068.88 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256518E+09 | 7075470.45 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.309911E+09 | 87265.23 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336234E+09 | 41393.43 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215724E+09 | 6782562.39 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124439E+09 | 26165691.93 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 48240439.14 | 71121938.17 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7193527.07 | 0.143055E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163967E+10 | 0.793942E+09 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 976057.02 | 41393.43 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336234E+09 | 0.183454E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2701620.55 | 0.115648E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19449292.07 | 97526759.50 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 64366540.17 | 46057750.42 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140389E+09 | 15729631.16 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295873E+09 | 816827.45 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376731E+09 | 24291.93 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450669E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464091E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.334012E+09 | 50570.41 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212724E+09 | 831946.67 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94966236.25 | 15314517.34 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15117189.72 | 71494592.89 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247109E+10 | 0.363495E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2701620.55 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464091E+09 | 0.115648E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1629552.47 | 69958184.98 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11731329.48 | 58985162.51 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38824305.53 | 27850371.75 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84679164.47 | 9494902.09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178463E+09 | 492689.01 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227234E+09 | 14652.19 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271832E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201467E+09 | 30502.76 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128310E+09 | 501808.85 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57281250.63 | 9237323.24 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9118315.15 | 43135775.59 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149050E+10 | 0.219701E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1629552.47 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 69958184.98 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1629552.47 | 69958658.75 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11731329.49 | 58985520.82 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38824305.63 | 27850077.59 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84679164.76 | 9494900.77 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178463E+09 | 492689.01 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227234E+09 | 14652.19 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271832E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201467E+09 | 30502.76 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128310E+09 | 501808.84 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57281250.78 | 9237323.21 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9118315.19 | 43135792.80 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149050E+10 | 0.219702E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1629552.47 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 69958658.75 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1629549.67 | 70021404.24 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11731322.33 | 59021920.21 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38824292.01 | 27871162.87 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84679156.38 | 9494893.45 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178463E+09 | 492689.18 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227234E+09 | 14652.21 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271832E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201467E+09 | 30502.73 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128310E+09 | 501808.50 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57281247.61 | 9237325.72 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9118309.53 | 43138703.30 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149050E+10 | 0.219825E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1629549.67 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 70021404.24 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1629548.96 | 70022757.21 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11731321.47 | 59026487.33 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38824287.99 | 27882017.62 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84679154.05 | 9494896.36 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178463E+09 | 492689.48 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227234E+09 | 14652.22 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271832E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201467E+09 | 30502.67 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128310E+09 | 501808.15 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57281247.75 | 9237326.96 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9118309.03 | 43138911.94 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149050E+10 | 0.219842E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1629548.96 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279928E+09 | 70022757.21 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3824873.61 | 0.166643E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27763221.92 | 0.140914E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91996857.66 | 66787563.54 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200997E+09 | 22799662.35 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424269E+09 | 1193717.12 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540313E+09 | 37106.49 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.646564E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478998E+09 | 75040.64 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304822E+09 | 1229397.98 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135819E+09 | 22190157.78 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21497478.22 | 0.103064E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354270E+10 | 0.524934E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3824873.61 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.166643E+09 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3824886.67 | 0.165113E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27763236.27 | 0.140374E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91996885.67 | 66700175.10 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200997E+09 | 22799812.63 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424269E+09 | 1193716.84 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540313E+09 | 37106.46 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.646564E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478998E+09 | 75040.70 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304822E+09 | 1229398.46 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135819E+09 | 22180372.77 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21497497.90 | 0.102695E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354270E+10 | 0.522397E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3824886.67 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.165113E+09 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3824875.19 | 0.166768E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27763227.01 | 0.140983E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91996879.93 | 66812851.21 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200997E+09 | 22797911.02 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424269E+09 | 1193716.91 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540313E+09 | 37106.45 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.646564E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478998E+09 | 75040.60 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304822E+09 | 1229397.86 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135819E+09 | 22190836.02 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21497484.39 | 0.103100E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354270E+10 | 0.525188E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3824875.19 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.166768E+09 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3824887.14 | 0.165475E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27763240.01 | 0.140502E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91996905.14 | 66754898.82 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200997E+09 | 22798026.69 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424269E+09 | 1193716.62 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540313E+09 | 37106.42 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.646564E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478998E+09 | 75040.66 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304822E+09 | 1229398.42 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135819E+09 | 22182712.59 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21497496.60 | 0.102799E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354270E+10 | 0.523047E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3824887.14 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665841E+09 | 0.165475E+09 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2307078.94 | 0.100800E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16746095.62 | 85205888.92 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55490238.01 | 40347344.89 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121236E+09 | 13761521.78 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255908E+09 | 720018.74 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325903E+09 | 22381.55 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389991E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288919E+09 | 45262.60 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183861E+09 | 741541.85 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81922881.21 | 13389984.02 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12966760.33 | 62281051.87 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213687E+10 | 0.317315E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2307078.94 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.100800E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2307078.93 | 0.100802E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16746095.64 | 85206451.61 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55490240.08 | 40347355.70 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121236E+09 | 13761506.98 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255908E+09 | 720018.73 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325903E+09 | 22381.55 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389991E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288919E+09 | 45262.60 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183861E+09 | 741541.85 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81922881.38 | 13389939.54 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12966760.36 | 62281389.11 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213687E+10 | 0.317318E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2307078.93 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.100802E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2307073.55 | 0.101078E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16746086.35 | 85288731.50 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55490225.03 | 40363198.05 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121236E+09 | 13761721.05 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255908E+09 | 720018.87 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325903E+09 | 22381.56 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389991E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288919E+09 | 45262.54 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183861E+09 | 741541.18 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81922873.96 | 13391243.90 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12966750.80 | 62339561.75 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213687E+10 | 0.317751E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2307073.55 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.101078E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2307073.58 | 0.101078E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16746086.41 | 85288969.84 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55490225.16 | 40363020.76 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121236E+09 | 13761721.02 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255908E+09 | 720018.87 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325903E+09 | 22381.56 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389991E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288919E+09 | 45262.54 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183861E+09 | 741541.18 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81922874.20 | 13391243.85 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12966750.86 | 62339587.58 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213687E+10 | 0.317752E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2307073.58 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401618E+09 | 0.101078E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4907246.07 | 0.204762E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36234602.20 | 0.176243E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120367E+09 | 85323431.23 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263884E+09 | 29961541.15 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558780E+09 | 1632351.66 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.711871E+09 | 54896.91 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.852409E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877877E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.630963E+09 | 105529.01 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.400891E+09 | 1716281.06 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177933E+09 | 29108921.38 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27839150.79 | 0.129491E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.466396E+10 | 0.658400E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4907246.07 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877877E+09 | 0.204762E+09 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4908186.85 | 0.197899E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36238030.25 | 0.173158E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120367E+09 | 84756294.95 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263884E+09 | 29968813.65 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558779E+09 | 1632351.72 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.711871E+09 | 54896.91 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.852409E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877877E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.630963E+09 | 105529.05 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.400891E+09 | 1716281.76 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177933E+09 | 28850588.66 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27839184.35 | 0.126639E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.466396E+10 | 0.644781E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4908186.85 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877877E+09 | 0.197899E+09 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4907249.83 | 0.205897E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36233362.26 | 0.176776E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120367E+09 | 85677805.67 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263884E+09 | 29969311.40 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558779E+09 | 1632351.63 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.711871E+09 | 54896.85 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.852409E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877878E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.630963E+09 | 105528.94 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.400891E+09 | 1716281.14 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177933E+09 | 29161929.18 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27839164.81 | 0.129960E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.466395E+10 | 0.660952E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4907249.83 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877878E+09 | 0.205897E+09 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4907270.83 | 0.199580E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36235271.38 | 0.173928E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120367E+09 | 85156468.77 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263884E+09 | 29972442.20 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558779E+09 | 1632351.62 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.711871E+09 | 54896.85 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.852409E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877878E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.630963E+09 | 105528.98 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.400891E+09 | 1716281.54 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177933E+09 | 28939652.03 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27839194.38 | 0.127466E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.466396E+10 | 0.648552E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4907270.83 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877878E+09 | 0.199580E+09 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2959949.46 | 0.124562E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21854944.57 | 0.108473E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72602476.69 | 52410501.36 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159168E+09 | 18318148.08 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337042E+09 | 984592.53 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.429383E+09 | 33112.29 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514152E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380581E+09 | 63652.38 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241807E+09 | 1035217.88 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107325E+09 | 17731631.20 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16791912.18 | 79414667.63 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281318E+10 | 0.403027E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2959949.46 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.124562E+09 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2959949.11 | 0.124590E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21854944.56 | 0.108474E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72602477.45 | 52410480.62 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159168E+09 | 18316950.05 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337042E+09 | 984592.52 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.429383E+09 | 33112.29 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514152E+09 | 0.00 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.00 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380581E+09 | 63652.38 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241807E+09 | 1035217.89 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107325E+09 | 17731192.62 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16791912.18 | 79421439.27 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281318E+10 | 0.403061E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2959949.11 | 0.00 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.124590E+09 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2959936.56 | 0.128172E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21854930.82 | 0.109881E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72602458.28 | 52662720.49 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159168E+09 | 18317092.36 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337042E+09 | 984592.62 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.429383E+09 | 33112.30 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514152E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380581E+09 | 63652.36 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241807E+09 | 1035217.49 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107325E+09 | 17828192.67 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16791891.80 | 80654155.31 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281318E+10 | 0.409632E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2959936.56 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.128172E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2959936.42 | 0.128183E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21854931.28 | 0.109881E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72602459.15 | 52662499.83 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159168E+09 | 18315798.31 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337042E+09 | 984592.53 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.429383E+09 | 33112.29 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514152E+09 | 0.00 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.00 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380581E+09 | 63652.35 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241807E+09 | 1035217.36 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107325E+09 | 17827868.68 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16791893.55 | 80653954.37 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281318E+10 | 0.409640E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2959936.42 | 0.00 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529514E+09 | 0.128183E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213052.78 | 46582796.19 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3070180.76 | 44080931.79 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11023465.88 | 26321177.39 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25219763.94 | 9960142.96 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65242078.75 | 978465.36 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85333321.45 | 178921.80 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106301E+09 | 0.00 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109937E+09 | 0.00 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74478957.33 | 124871.39 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43034909.21 | 1583809.31 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15006558.20 | 9309205.26 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1272293.77 | 32718854.64 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540133E+09 | 0.171839E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213052.78 | 0.00 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109937E+09 | 46582796.19 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1726259.62 | 0.122955E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 39527229.80 | 0.896112E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139913E+09 | 0.656851E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.390986E+09 | 0.297913E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.991007E+09 | 69233623.59 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116298E+10 | 19473249.13 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150943E+10 | 0.00 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151520E+10 | 0.00 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102023E+10 | 30149572.63 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.646872E+09 | 0.133179E+09 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189661E+09 | 0.352658E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12841408.59 | 0.917815E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.762038E+10 | 0.460294E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1726259.62 | 0.00 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151520E+10 | 0.122955E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 125834.73 | 41019428.78 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2444269.23 | 37215639.45 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8967109.18 | 21629945.49 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21468549.53 | 8092752.43 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54313340.48 | 862159.59 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70370269.52 | 160920.34 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87735534.33 | 0.00 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90554332.90 | 0.00 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61516086.98 | 122763.66 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35738298.58 | 1459884.12 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12502083.44 | 7987188.61 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1038419.56 | 28048004.54 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.446774E+09 | 0.146599E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 125834.73 | 0.00 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90554332.90 | 41019428.78 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 29-JAN-12:00 | 208.87 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 217.11 | 05-FEB-15:00 | 168.48 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.36 | 01-MAR-13:00 | 197.54 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 508.29 | 28-APR-13:20 | 98.36 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 21-MAY-13:00 | 30.42 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 537.14 | 09-JUN-16:00 | 17.36 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 634.31 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 563.40 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 447.86 | 14-SEP-13:00 | 8.13 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 459.94 | 19-OCT-15:00 | 32.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 231.12 | 19-NOV-14:00 | 87.89 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.10 | 10-DEC-13:00 | 221.27 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 221.27 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 29-JAN-12:00 | 203.57 | 19-JAN-09:40 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 217.11 | 05-FEB-15:00 | 164.71 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.36 | 01-MAR-13:00 | 197.54 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 508.29 | 28-APR-13:20 | 98.36 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 21-MAY-13:00 | 30.42 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 537.14 | 09-JUN-16:00 | 17.36 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 634.31 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 563.40 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 447.86 | 14-SEP-13:00 | 8.13 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 459.94 | 19-OCT-15:00 | 32.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 231.12 | 19-NOV-14:00 | 87.89 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.10 | 10-DEC-13:00 | 221.27 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 221.27 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 80.71 | 23-JAN-13:00 | 281.68 | 18-JAN-04:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 198.18 | 06-FEB-15:00 | 246.51 | 10-FEB-20:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 408.37 | 01-MAR-13:00 | 443.71 | 25-MAR-09:00 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 508.29 | 28-APR-13:20 | 149.52 | 05-APR-01:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 860.90 | 21-MAY-13:00 | 68.90 | 01-MAY-07:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 537.11 | 09-JUN-16:00 | 76.91 | 07-JUN-06:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 634.27 | 14-JUL-14:00 | 5.48 | 03-JUL-05:50 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 563.39 | 16-AUG-12:00 | 4.68 | 27-AUG-06:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 447.84 | 14-SEP-13:00 | 66.52 | 27-SEP-06:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 459.94 | 19-OCT-15:00 | 118.02 | 20-OCT-05:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.07 | 01-NOV-14:00 | 129.00 | 22-NOV-07:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 77.44 | 04-DEC-15:00 | 221.27 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 77.44 | 4.68 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 860.90 | 443.71 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 29-JAN-12:00 | 207.87 | 19-JAN-09:40 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 217.11 | 05-FEB-15:00 | 164.59 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 408.36 | 01-MAR-13:00 | 197.54 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 508.29 | 28-APR-13:20 | 98.36 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 21-MAY-13:00 | 30.42 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 537.14 | 09-JUN-16:00 | 17.36 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 634.31 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 563.40 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 447.86 | 14-SEP-13:00 | 8.13 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 459.94 | 19-OCT-15:00 | 32.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 231.12 | 19-NOV-14:00 | 87.89 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.10 | 10-DEC-13:00 | 221.27 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 221.27 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 29-JAN-12:00 | 125.99 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.95 | 05-FEB-15:00 | 102.45 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 246.32 | 01-MAR-13:00 | 119.15 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.59 | 28-APR-13:20 | 59.33 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 21-MAY-13:00 | 18.35 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.99 | 09-JUN-16:00 | 10.47 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 382.60 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 339.83 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.14 | 14-SEP-13:00 | 4.91 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 277.42 | 19-OCT-15:00 | 19.33 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.40 | 19-NOV-14:00 | 53.01 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.57 | 10-DEC-13:00 | 133.46 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 133.46 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 29-JAN-12:00 | 125.99 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.95 | 05-FEB-15:00 | 102.45 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 246.32 | 01-MAR-13:00 | 119.15 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.59 | 28-APR-13:20 | 59.33 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 21-MAY-13:00 | 18.35 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.99 | 09-JUN-16:00 | 10.47 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 382.60 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 339.83 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.14 | 14-SEP-13:00 | 4.91 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 277.42 | 19-OCT-15:00 | 19.33 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.40 | 19-NOV-14:00 | 53.01 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.57 | 10-DEC-13:00 | 133.46 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 133.46 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 29-JAN-12:00 | 125.99 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.95 | 05-FEB-15:00 | 103.53 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 246.32 | 01-MAR-13:00 | 119.15 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.59 | 28-APR-13:20 | 59.33 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 21-MAY-13:00 | 18.35 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.99 | 09-JUN-16:00 | 10.47 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 382.60 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 339.83 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.14 | 14-SEP-13:00 | 4.91 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 277.42 | 19-OCT-15:00 | 19.33 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.40 | 19-NOV-14:00 | 53.01 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.57 | 10-DEC-13:00 | 133.46 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 133.46 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 29-JAN-12:00 | 125.99 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.95 | 05-FEB-15:00 | 103.53 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 246.32 | 01-MAR-13:00 | 119.15 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 306.59 | 28-APR-13:20 | 59.33 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 21-MAY-13:00 | 18.35 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 323.99 | 09-JUN-16:00 | 10.47 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 382.60 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 339.83 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.14 | 14-SEP-13:00 | 4.91 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 277.42 | 19-OCT-15:00 | 19.33 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.40 | 19-NOV-14:00 | 53.01 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.57 | 10-DEC-13:00 | 133.46 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 49.99 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 133.46 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 29-JAN-12:00 | 292.89 | 19-JAN-09:40 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 311.23 | 05-FEB-15:00 | 237.12 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 585.81 | 01-MAR-13:00 | 277.83 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 729.25 | 28-APR-13:20 | 141.76 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 21-MAY-13:00 | 43.99 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 771.02 | 09-JUN-16:00 | 25.11 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 910.55 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 808.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 642.76 | 14-SEP-13:00 | 11.92 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 659.87 | 19-OCT-15:00 | 46.51 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.19 | 19-NOV-14:00 | 124.72 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.06 | 10-DEC-13:00 | 306.54 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 306.54 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 29-JAN-12:00 | 279.78 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 311.23 | 05-FEB-15:00 | 234.15 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 585.81 | 01-MAR-13:00 | 267.34 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 729.25 | 28-APR-13:20 | 141.76 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 21-MAY-13:00 | 43.99 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 771.02 | 09-JUN-16:00 | 25.11 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 910.55 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 808.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 642.76 | 14-SEP-13:00 | 11.92 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 659.87 | 19-OCT-15:00 | 46.51 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.19 | 19-NOV-14:00 | 124.72 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.06 | 10-DEC-13:00 | 304.18 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 304.18 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 29-JAN-12:00 | 299.80 | 19-JAN-09:40 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 311.23 | 05-FEB-15:00 | 236.92 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 585.81 | 01-MAR-13:00 | 286.13 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 729.25 | 28-APR-13:20 | 141.76 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 21-MAY-13:00 | 43.99 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 771.02 | 09-JUN-16:00 | 25.11 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 910.55 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 808.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 642.76 | 14-SEP-13:00 | 11.92 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 659.87 | 19-OCT-15:00 | 46.51 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.19 | 19-NOV-14:00 | 124.72 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.06 | 10-DEC-13:00 | 307.00 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 307.00 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 29-JAN-12:00 | 287.18 | 19-JAN-09:40 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 311.23 | 05-FEB-15:00 | 234.15 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 585.81 | 01-MAR-13:00 | 286.11 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 729.25 | 28-APR-13:20 | 141.76 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 21-MAY-13:00 | 43.99 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 771.02 | 09-JUN-16:00 | 25.11 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 910.55 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 808.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 642.76 | 14-SEP-13:00 | 11.92 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 659.87 | 19-OCT-15:00 | 46.51 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.19 | 19-NOV-14:00 | 124.72 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.06 | 10-DEC-13:00 | 304.67 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 304.67 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 29-JAN-12:00 | 178.57 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 187.72 | 05-FEB-15:00 | 146.04 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 353.35 | 01-MAR-13:00 | 170.64 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 28-APR-13:20 | 85.51 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 21-MAY-13:00 | 26.53 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.06 | 09-JUN-16:00 | 15.14 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 549.22 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 487.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 387.69 | 14-SEP-13:00 | 7.19 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 398.02 | 19-OCT-15:00 | 28.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.77 | 19-NOV-14:00 | 75.93 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.88 | 10-DEC-13:00 | 189.32 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 189.32 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 29-JAN-12:00 | 178.67 | 19-JAN-09:40 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 187.72 | 05-FEB-15:00 | 146.04 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 353.35 | 01-MAR-13:00 | 170.85 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 28-APR-13:20 | 85.51 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 21-MAY-13:00 | 26.53 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.06 | 09-JUN-16:00 | 15.14 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 549.22 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 487.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 387.69 | 14-SEP-13:00 | 7.19 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 398.02 | 19-OCT-15:00 | 28.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.77 | 19-NOV-14:00 | 75.92 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.88 | 10-DEC-13:00 | 189.33 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 189.33 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 29-JAN-12:00 | 181.42 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 187.72 | 05-FEB-15:00 | 148.65 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 353.35 | 01-MAR-13:00 | 172.59 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 28-APR-13:20 | 85.51 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 21-MAY-13:00 | 26.53 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.06 | 09-JUN-16:00 | 15.14 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 549.22 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 487.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 387.69 | 14-SEP-13:00 | 7.19 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 398.02 | 19-OCT-15:00 | 28.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.77 | 19-NOV-14:00 | 76.40 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.88 | 10-DEC-13:00 | 190.55 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 190.55 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 29-JAN-12:00 | 181.42 | 19-JAN-09:30 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 187.72 | 05-FEB-15:00 | 148.64 | 13-FEB-04:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 353.35 | 01-MAR-13:00 | 172.59 | 25-MAR-08:50 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 28-APR-13:20 | 85.51 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 21-MAY-13:00 | 26.53 | 01-MAY-06:50 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.06 | 09-JUN-16:00 | 15.14 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 549.22 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 487.91 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 387.69 | 14-SEP-13:00 | 7.19 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 398.02 | 19-OCT-15:00 | 28.05 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.77 | 19-NOV-14:00 | 76.40 | 22-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.88 | 10-DEC-13:00 | 190.56 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 190.56 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 29-JAN-12:00 | 315.48 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 409.64 | 05-FEB-15:00 | 310.98 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 772.15 | 01-MAR-13:00 | 256.47 | 02-MAR-14:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 961.48 | 28-APR-13:20 | 177.74 | 05-APR-01:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.79 | 21-MAY-13:00 | 58.93 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1017.52 | 09-JUN-16:00 | 33.65 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1201.80 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1068.08 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 847.96 | 14-SEP-13:00 | 16.38 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 869.98 | 19-OCT-15:00 | 62.73 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 435.61 | 19-NOV-14:00 | 145.49 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.68 | 10-DEC-13:00 | 365.77 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.79 | 365.77 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 29-JAN-12:00 | 303.59 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 409.64 | 05-FEB-15:00 | 297.13 | 10-FEB-19:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 772.15 | 01-MAR-13:00 | 256.47 | 02-MAR-14:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 961.48 | 28-APR-13:20 | 177.47 | 05-APR-01:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.34 | 21-MAY-13:00 | 58.93 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1017.52 | 09-JUN-16:00 | 33.65 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1201.80 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1068.08 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 847.96 | 14-SEP-13:00 | 16.38 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 869.98 | 19-OCT-15:00 | 62.73 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 435.61 | 19-NOV-14:00 | 142.96 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.68 | 10-DEC-13:00 | 364.39 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.34 | 364.39 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 29-JAN-12:00 | 320.60 | 19-JAN-09:50 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 409.64 | 05-FEB-15:00 | 305.74 | 10-FEB-19:40 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 772.15 | 01-MAR-13:00 | 291.45 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 961.48 | 28-APR-13:20 | 177.58 | 05-APR-01:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.36 | 21-MAY-13:00 | 58.93 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1017.52 | 09-JUN-16:00 | 33.65 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1201.80 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1067.97 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 847.96 | 14-SEP-13:00 | 16.38 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 869.98 | 19-OCT-15:00 | 62.73 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 435.61 | 19-NOV-14:00 | 144.92 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.68 | 10-DEC-13:00 | 366.53 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.36 | 366.53 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 29-JAN-12:00 | 302.78 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 409.64 | 05-FEB-15:00 | 287.41 | 10-FEB-19:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 772.15 | 01-MAR-13:00 | 274.67 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 961.48 | 28-APR-13:20 | 176.99 | 05-APR-01:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.38 | 21-MAY-13:00 | 58.93 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1017.52 | 09-JUN-16:00 | 33.65 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1201.63 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1068.08 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 847.96 | 14-SEP-13:00 | 16.38 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 869.98 | 19-OCT-15:00 | 62.73 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 435.61 | 19-NOV-14:00 | 142.34 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.68 | 10-DEC-13:00 | 365.20 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.38 | 365.20 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 29-JAN-12:00 | 204.06 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.08 | 05-FEB-15:00 | 182.54 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.74 | 01-MAR-13:00 | 165.82 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 579.94 | 28-APR-13:20 | 108.76 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 21-MAY-13:00 | 35.55 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 613.74 | 09-JUN-16:00 | 20.30 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 724.89 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 644.24 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.47 | 14-SEP-13:00 | 9.88 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 524.75 | 19-OCT-15:00 | 37.84 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.75 | 19-NOV-14:00 | 92.87 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.19 | 10-DEC-13:00 | 232.25 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 232.25 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 29-JAN-12:00 | 204.04 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.08 | 05-FEB-15:00 | 182.24 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.74 | 01-MAR-13:00 | 166.45 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 579.94 | 28-APR-13:20 | 108.70 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 21-MAY-13:00 | 35.55 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 613.74 | 09-JUN-16:00 | 20.30 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 724.89 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 644.24 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.47 | 14-SEP-13:00 | 9.88 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 524.75 | 19-OCT-15:00 | 37.84 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.75 | 19-NOV-14:00 | 92.83 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.19 | 10-DEC-13:00 | 232.27 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 232.27 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 29-JAN-12:00 | 211.56 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.08 | 05-FEB-15:00 | 188.30 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.74 | 01-MAR-13:00 | 176.51 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 579.94 | 28-APR-13:20 | 109.57 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 21-MAY-13:00 | 35.55 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 613.74 | 09-JUN-16:00 | 20.30 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 724.89 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 644.24 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.47 | 14-SEP-13:00 | 9.88 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 524.75 | 19-OCT-15:00 | 37.84 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.75 | 19-NOV-14:00 | 94.48 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.19 | 10-DEC-13:00 | 233.11 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 233.11 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 29-JAN-12:00 | 211.52 | 18-JAN-04:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.08 | 05-FEB-15:00 | 188.30 | 10-FEB-20:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 465.74 | 01-MAR-13:00 | 177.15 | 25-MAR-08:40 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 579.94 | 28-APR-13:20 | 109.51 | 05-APR-04:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 21-MAY-13:00 | 35.55 | 01-MAY-07:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 613.74 | 09-JUN-16:00 | 20.30 | 22-JUN-08:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 724.89 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 644.24 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.47 | 14-SEP-13:00 | 9.88 | 25-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 524.75 | 19-OCT-15:00 | 37.84 | 21-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.75 | 19-NOV-14:00 | 94.43 | 22-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.19 | 10-DEC-13:00 | 233.13 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 93.14 | 0.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 233.13 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.06 | 23-JAN-13:00 | 70.46 | 18-JAN-04:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.14 | 05-FEB-15:00 | 67.31 | 10-FEB-20:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.49 | 27-MAR-11:00 | 74.39 | 25-MAR-08:50 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.45 | 28-APR-13:00 | 38.15 | 05-APR-01:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 329.05 | 21-MAY-13:00 | 15.15 | 01-MAY-07:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.55 | 09-JUN-15:00 | 9.92 | 22-JUN-08:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.73 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.94 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.69 | 14-SEP-13:00 | 7.62 | 25-SEP-05:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.99 | 19-OCT-15:00 | 17.53 | 21-OCT-07:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.66 | 19-NOV-14:00 | 30.57 | 22-NOV-06:05 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.38 | 10-DEC-12:00 | 83.46 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.06 | 0.00 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 329.05 | 83.46 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.18 | 28-JAN-14:00 | 7262.60 | 19-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1935.58 | 05-FEB-17:03 | 6651.72 | 01-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3677.46 | 27-MAR-16:01 | 5683.28 | 07-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3832.15 | 27-APR-16:02 | 4613.52 | 05-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5234.28 | 30-MAY-16:01 | 3151.31 | 01-MAY-06:02 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6395.69 | 09-JUN-16:01 | 1408.11 | 07-JUN-06:03 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6660.50 | 03-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6270.73 | 10-AUG-16:01 | 0.00 | 01-AUG-00:10 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5858.65 | 04-SEP-16:01 | 1975.26 | 25-SEP-06:03 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4128.12 | 09-OCT-16:01 | 3155.89 | 29-OCT-06:02 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2207.84 | 01-NOV-16:01 | 4842.66 | 22-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 265.57 | 10-DEC-12:00 | 6738.22 | 31-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 153.18 | 0.00 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 6660.50 | 7262.60 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.78 | 23-JAN-13:20 | 60.68 | 18-JAN-04:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.41 | 05-FEB-15:00 | 54.19 | 10-FEB-20:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.94 | 27-MAR-11:00 | 81.79 | 25-MAR-09:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.68 | 28-APR-13:00 | 31.29 | 05-APR-01:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 275.96 | 21-MAY-13:00 | 12.64 | 01-MAY-07:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.88 | 09-JUN-15:10 | 8.29 | 07-JUN-06:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 133.19 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.37 | 16-AUG-12:00 | 0.00 | 01-AUG-00:10 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.58 | 14-SEP-13:00 | 6.30 | 25-SEP-05:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.96 | 19-OCT-15:00 | 15.79 | 21-OCT-07:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.24 | 19-NOV-14:00 | 26.94 | 22-NOV-07:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.03 | 10-DEC-13:00 | 68.18 | 15-DEC-12:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.78 | 0.00 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 275.96 | 81.79 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1597.67 | 28-JAN-14:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 47.73 | 0.00 |
| February | 1982.51 | 05-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 214.59 | 0.00 |
| March | 2161.86 | 01-MAR-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 365.88 | 0.00 |
| April | 2207.97 | 28-APR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 427.42 | 0.00 |
| May | 3087.05 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 0.00 |
| June | 2749.46 | 09-JUN-16:40 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 514.57 | 0.00 |
| July | 2906.38 | 21-JUL-17:04 | 1662.50 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 447.78 | 0.00 |
| August | 2992.95 | 10-AUG-16:02 | 0.00 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 435.56 | 0.00 |
| September | 2993.02 | 04-SEP-16:40 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 343.96 | 0.00 |
| October | 2868.84 | 09-OCT-16:01 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 313.40 | 0.00 |
| November | 2467.08 | 05-NOV-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 197.61 | 0.00 |
| December | 1907.34 | 03-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 65.85 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1597.67 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 47.73 | 0.00 | |
| Maximum of Months | 3087.05 | 1662.50 | 820.27 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1188.94 | 29-JAN-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 8.65 | 0.00 |
| February | 1495.67 | 06-FEB-15:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 185.71 | 0.00 |
| March | 1933.07 | 27-MAR-16:01 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 272.83 | 0.00 |
| April | 2117.99 | 28-APR-16:07 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 338.85 | 0.00 |
| May | 3047.94 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 0.00 |
| June | 2834.81 | 09-JUN-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 503.34 | 0.00 |
| July | 2945.10 | 21-JUL-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 463.88 | 0.00 |
| August | 2937.64 | 10-AUG-16:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 435.56 | 0.00 |
| September | 2795.45 | 04-SEP-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 360.55 | 0.00 |
| October | 2456.64 | 19-OCT-16:06 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 436.47 | 0.00 |
| November | 1968.41 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 169.23 | 0.00 |
| December | 1373.08 | 01-DEC-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 50.66 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1188.94 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 8.65 | 0.00 | |
| Maximum of Months | 3047.94 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 7556.64 | 17-JAN-09:02 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.68 |
| February | 7145.56 | 27-FEB-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.13 |
| March | 8028.46 | 14-MAR-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.31 |
| April | 8147.97 | 24-APR-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.50 |
| May | 7955.64 | 08-MAY-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.85 | 0.00 |
| June | 7754.95 | 02-JUN-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 15.30 | 0.00 |
| July | 7797.98 | 03-JUL-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 28.38 | 0.00 |
| August | 6606.61 | 07-AUG-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 23.41 | 0.00 |
| September | 7239.45 | 26-SEP-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.29 | 0.00 |
| October | 8254.81 | 20-OCT-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.02 |
| November | 7961.95 | 22-NOV-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.30 |
| December | 8129.06 | 27-DEC-08:62 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.13 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 6606.61 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 8254.81 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 28.38 | 127.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1114.37 | 29-JAN-12:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 0.00 |
| February | 1385.64 | 06-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 194.03 | 0.00 |
| March | 1795.97 | 27-MAR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 387.16 | 0.00 |
| April | 2147.61 | 28-APR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 507.51 | 0.00 |
| May | 3145.18 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 0.00 |
| June | 2615.02 | 09-JUN-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 503.34 | 0.00 |
| July | 2795.13 | 21-JUL-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 463.88 | 0.00 |
| August | 2886.38 | 05-AUG-11:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 560.10 | 0.00 |
| September | 2621.87 | 04-SEP-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 360.55 | 0.00 |
| October | 2283.60 | 09-OCT-16:01 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 313.40 | 0.00 |
| November | 1838.59 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 169.23 | 0.00 |
| December | 1305.13 | 10-DEC-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 97.10 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1114.37 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 82.87 | 0.00 | |
| Maximum of Months | 3145.18 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 1401.47 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 937.41 | 29-JAN-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 5.22 | 0.00 |
| February | 1104.73 | 06-FEB-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 90.83 | 0.00 |
| March | 1383.26 | 27-MAR-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 164.56 | 0.00 |
| April | 1547.89 | 28-APR-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 215.40 | 0.00 |
| May | 2153.60 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
| June | 1998.47 | 09-JUN-17:03 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 291.02 | 0.00 |
| July | 2117.67 | 21-JUL-17:06 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 270.09 | 0.00 |
| August | 2087.39 | 05-AUG-17:14 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 185.43 | 0.00 |
| September | 1997.23 | 04-SEP-17:03 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 210.34 | 0.00 |
| October | 1747.91 | 09-OCT-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 183.46 | 0.00 |
| November | 1452.41 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 102.08 | 0.00 |
| December | 1079.63 | 10-DEC-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.18 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 937.41 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 5.22 | 0.00 | |
| Maximum of Months | 2153.60 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 936.45 | 29-JAN-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 5.22 | 0.00 |
| February | 1103.14 | 05-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 84.09 | 0.00 |
| March | 1381.57 | 27-MAR-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 164.56 | 0.00 |
| April | 1546.18 | 28-APR-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 215.40 | 0.00 |
| May | 2157.24 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
| June | 1994.82 | 09-JUN-17:03 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 291.02 | 0.00 |
| July | 2115.02 | 21-JUL-17:06 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 270.09 | 0.00 |
| August | 2085.41 | 05-AUG-17:14 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 185.43 | 0.00 |
| September | 1994.60 | 04-SEP-17:03 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 210.34 | 0.00 |
| October | 1745.66 | 09-OCT-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 183.46 | 0.00 |
| November | 1450.68 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 102.08 | 0.00 |
| December | 1079.19 | 10-DEC-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.18 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 936.45 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 5.22 | 0.00 | |
| Maximum of Months | 2157.24 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1394.84 | 28-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 24.73 | 0.00 |
| February | 1633.99 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 121.23 | 0.00 |
| March | 1612.73 | 27-MAR-16:01 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 164.56 | 0.00 |
| April | 1648.92 | 28-APR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 306.12 | 0.00 |
| May | 2199.07 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
| June | 1916.63 | 09-JUN-17:03 | 1662.50 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 291.02 | 0.00 |
| July | 2087.40 | 21-JUL-17:06 | 1662.50 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 270.09 | 0.00 |
| August | 2117.99 | 10-AUG-16:02 | 0.00 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 262.72 | 0.00 |
| September | 2182.85 | 04-SEP-17:00 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 217.48 | 0.00 |
| October | 2175.54 | 09-OCT-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 189.04 | 0.00 |
| November | 1952.50 | 05-NOV-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 120.67 | 0.00 |
| December | 1632.73 | 03-DEC-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 39.53 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1394.84 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 24.73 | 0.00 | |
| Maximum of Months | 2199.07 | 1662.50 | 820.27 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1480.80 | 28-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 24.73 | 0.00 |
| February | 1759.72 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 121.23 | 0.00 |
| March | 1703.81 | 27-MAR-16:01 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 164.56 | 0.00 |
| April | 1737.05 | 28-APR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 306.12 | 0.00 |
| May | 2359.28 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
| June | 2004.22 | 09-JUN-17:03 | 1662.50 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 291.02 | 0.00 |
| July | 2180.65 | 30-JUL-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 293.77 | 0.00 |
| August | 2268.51 | 13-AUG-16:02 | 1900.00 | 694.39 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 232.11 | 0.00 |
| September | 2364.32 | 04-SEP-17:00 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 217.48 | 0.00 |
| October | 2357.91 | 09-OCT-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 189.04 | 0.00 |
| November | 2121.45 | 05-NOV-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 120.67 | 0.00 |
| December | 1775.99 | 03-DEC-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 39.53 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1480.80 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 24.73 | 0.00 | |
| Maximum of Months | 2364.32 | 1900.00 | 820.27 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 845.33 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1746.42 | 28-JAN-14:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 68.08 | 0.00 |
| February | 2294.66 | 05-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 307.62 | 0.00 |
| March | 2603.67 | 01-MAR-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 524.94 | 0.00 |
| April | 2640.65 | 28-APR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 613.11 | 0.00 |
| May | 3825.35 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
| June | 3142.39 | 09-JUN-16:03 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 762.89 | 0.00 |
| July | 3135.38 | 21-JUL-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 644.62 | 0.00 |
| August | 3132.61 | 10-AUG-16:02 | 0.00 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 625.21 | 0.00 |
| September | 3048.66 | 04-SEP-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 481.46 | 0.00 |
| October | 2974.23 | 19-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 657.07 | 0.00 |
| November | 2492.36 | 05-NOV-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 283.25 | 0.00 |
| December | 1961.89 | 03-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 94.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1746.42 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 68.08 | 0.00 | |
| Maximum of Months | 3825.35 | 237.50 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1215.53 | 29-JAN-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 12.13 | 0.00 |
| February | 1691.96 | 06-FEB-15:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 266.21 | 0.00 |
| March | 2295.31 | 27-MAR-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 391.36 | 0.00 |
| April | 2526.21 | 28-APR-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 613.11 | 0.00 |
| May | 3770.80 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
| June | 3224.95 | 09-JUN-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 746.69 | 0.00 |
| July | 3165.97 | 21-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 644.62 | 0.00 |
| August | 3071.53 | 10-AUG-16:10 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 625.21 | 0.00 |
| September | 2815.11 | 04-SEP-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 493.69 | 0.00 |
| October | 2515.49 | 19-OCT-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 626.10 | 0.00 |
| November | 1893.90 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 242.60 | 0.00 |
| December | 1277.49 | 01-DEC-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 72.28 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1215.53 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 12.13 | 0.00 | |
| Maximum of Months | 3770.80 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1726.93 | 28-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 58.62 | 0.00 |
| February | 2240.00 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 288.08 | 0.00 |
| March | 2487.56 | 27-MAR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 555.46 | 0.00 |
| April | 2724.27 | 28-APR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 728.19 | 0.00 |
| May | 3942.22 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
| June | 2874.62 | 09-JUN-16:03 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 762.89 | 0.00 |
| July | 2950.57 | 30-JUL-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 699.08 | 0.00 |
| August | 3095.39 | 16-AUG-12:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 808.91 | 0.00 |
| September | 2817.55 | 04-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 504.79 | 0.00 |
| October | 2773.30 | 19-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 657.07 | 0.00 |
| November | 2351.22 | 05-NOV-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 241.04 | 0.00 |
| December | 1907.03 | 03-DEC-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 89.23 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1726.93 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 58.62 | 0.00 | |
| Maximum of Months | 3942.22 | 237.50 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1143.58 | 29-JAN-12:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 |
| February | 1543.42 | 06-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 278.17 | 0.00 |
| March | 2145.04 | 27-MAR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 555.46 | 0.00 |
| April | 2574.53 | 28-APR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 728.19 | 0.00 |
| May | 3886.46 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
| June | 2944.65 | 09-JUN-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 754.79 | 0.00 |
| July | 2966.29 | 21-JUL-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 665.89 | 0.00 |
| August | 3009.62 | 05-AUG-11:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 804.06 | 0.00 |
| September | 2574.94 | 04-SEP-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 505.70 | 0.00 |
| October | 2278.93 | 19-OCT-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 626.10 | 0.00 |
| November | 1731.14 | 01-NOV-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 283.06 | 0.00 |
| December | 1248.68 | 10-DEC-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 139.06 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1143.58 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 | |
| Maximum of Months | 3886.46 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.16 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 941.92 | 29-JAN-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.32 | 0.00 |
| February | 1202.69 | 05-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 120.50 | 0.00 |
| March | 1560.95 | 27-MAR-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 236.06 | 0.00 |
| April | 1743.03 | 28-APR-13:30 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 439.50 | 0.00 |
| May | 2556.86 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
| June | 2135.66 | 09-JUN-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 450.39 | 0.00 |
| July | 2151.43 | 21-JUL-17:04 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 387.71 | 0.00 |
| August | 2056.13 | 10-AUG-16:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 377.11 | 0.00 |
| September | 1897.92 | 04-SEP-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 312.14 | 0.00 |
| October | 1697.35 | 19-OCT-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 377.65 | 0.00 |
| November | 1356.86 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 146.33 | 0.00 |
| December | 1017.49 | 10-DEC-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 43.07 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 941.92 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 7.32 | 0.00 | |
| Maximum of Months | 2556.86 | 1446.38 | 820.27 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 940.76 | 29-JAN-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.32 | 0.00 |
| February | 1201.40 | 05-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 120.50 | 0.00 |
| March | 1558.97 | 27-MAR-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 236.06 | 0.00 |
| April | 1747.14 | 28-APR-13:30 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 439.50 | 0.00 |
| May | 2561.15 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
| June | 2132.17 | 09-JUN-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 450.39 | 0.00 |
| July | 2148.72 | 21-JUL-17:04 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 387.71 | 0.00 |
| August | 2053.79 | 10-AUG-16:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 377.11 | 0.00 |
| September | 1894.87 | 04-SEP-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 312.14 | 0.00 |
| October | 1694.75 | 19-OCT-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 377.65 | 0.00 |
| November | 1354.94 | 01-NOV-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 146.33 | 0.00 |
| December | 1017.12 | 10-DEC-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 43.07 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 940.76 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 7.32 | 0.00 | |
| Maximum of Months | 2561.15 | 1446.38 | 820.27 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1541.08 | 28-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 35.36 | 0.00 |
| February | 1850.71 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 173.76 | 0.00 |
| March | 1865.23 | 01-MAR-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 328.62 | 0.00 |
| April | 1886.56 | 28-APR-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 0.00 |
| May | 2611.86 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
| June | 2057.82 | 09-JUN-16:07 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 460.16 | 0.00 |
| July | 2116.59 | 21-JUL-17:04 | 1662.50 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 387.71 | 0.00 |
| August | 2116.73 | 10-AUG-16:02 | 0.00 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 377.11 | 0.00 |
| September | 2119.71 | 04-SEP-16:13 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 282.90 | 0.00 |
| October | 2152.25 | 09-OCT-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 277.68 | 0.00 |
| November | 1935.48 | 05-NOV-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 172.98 | 0.00 |
| December | 1678.11 | 03-DEC-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 53.82 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1541.08 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.36 | 0.00 | |
| Maximum of Months | 2611.86 | 1662.50 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1544.39 | 28-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 35.36 | 0.00 |
| February | 1853.48 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 173.76 | 0.00 |
| March | 1863.11 | 01-MAR-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 328.62 | 0.00 |
| April | 1890.96 | 28-APR-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 0.00 |
| May | 2616.16 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
| June | 2054.86 | 09-JUN-16:07 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 460.16 | 0.00 |
| July | 2113.90 | 21-JUL-17:04 | 1662.50 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 387.71 | 0.00 |
| August | 2114.39 | 10-AUG-16:02 | 0.00 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 377.11 | 0.00 |
| September | 2117.17 | 04-SEP-16:13 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 282.90 | 0.00 |
| October | 2151.43 | 09-OCT-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 277.68 | 0.00 |
| November | 1934.70 | 05-NOV-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 172.98 | 0.00 |
| December | 1679.81 | 03-DEC-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 53.82 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1544.39 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.36 | 0.00 | |
| Maximum of Months | 2616.16 | 1662.50 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.08 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2172.50 | 22-JAN-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 44.15 | 0.00 |
| February | 3026.95 | 05-FEB-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 409.64 | 0.00 |
| March | 3624.86 | 01-MAR-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 692.09 | 0.00 |
| April | 3681.30 | 28-APR-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 955.86 | 0.00 |
| May | 5260.77 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.79 | 0.00 |
| June | 4373.65 | 09-JUN-16:02 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1006.80 | 0.00 |
| July | 4366.83 | 21-JUL-16:20 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 841.42 | 0.00 |
| August | 4378.22 | 10-AUG-16:01 | 0.00 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 825.10 | 0.00 |
| September | 4179.22 | 04-SEP-16:10 | 2137.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 602.22 | 0.00 |
| October | 4001.35 | 19-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 866.26 | 0.00 |
| November | 3281.62 | 05-NOV-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 377.44 | 0.00 |
| December | 2538.30 | 03-DEC-14:20 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 122.69 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2172.50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 44.15 | 0.00 | |
| Maximum of Months | 5260.77 | 2137.50 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.79 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1474.40 | 29-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 28.35 | 0.00 |
| February | 2296.31 | 06-FEB-15:30 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 350.38 | 0.00 |
| March | 3137.66 | 27-MAR-16:01 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 515.78 | 0.00 |
| April | 3483.09 | 28-APR-14:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 932.62 | 0.00 |
| May | 5187.27 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.34 | 0.00 |
| June | 4457.22 | 09-JUN-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 996.10 | 0.00 |
| July | 4396.40 | 21-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 850.81 | 0.00 |
| August | 4283.45 | 10-AUG-16:01 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 825.10 | 0.00 |
| September | 3874.18 | 04-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 635.32 | 0.00 |
| October | 3367.74 | 19-OCT-15:20 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 862.35 | 0.00 |
| November | 2491.69 | 01-NOV-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 372.57 | 0.00 |
| December | 1627.65 | 10-DEC-13:50 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 173.99 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1474.40 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 28.35 | 0.00 | |
| Maximum of Months | 5187.27 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.34 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2098.31 | 28-JAN-14:20 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 86.48 | 0.00 |
| February | 2947.83 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 379.08 | 0.00 |
| March | 3466.35 | 27-MAR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 732.33 | 0.00 |
| April | 3859.82 | 28-APR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 960.22 | 0.00 |
| May | 5422.41 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.36 | 0.00 |
| June | 3968.09 | 09-JUN-16:02 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1006.80 | 0.00 |
| July | 4207.76 | 30-JUL-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 905.24 | 0.00 |
| August | 4389.71 | 16-AUG-12:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 1067.97 | 0.00 |
| September | 3972.35 | 04-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 666.17 | 0.00 |
| October | 3741.98 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 517.85 | 0.00 |
| November | 3158.53 | 05-NOV-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 317.47 | 0.00 |
| December | 2491.06 | 03-DEC-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 116.84 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2098.31 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 86.48 | 0.00 | |
| Maximum of Months | 5422.41 | 118.75 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.36 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1406.94 | 29-JAN-12:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 0.00 |
| February | 2079.22 | 06-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 366.20 | 0.00 |
| March | 3025.61 | 27-MAR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 732.33 | 0.00 |
| April | 3645.65 | 28-APR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 960.22 | 0.00 |
| May | 5352.40 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.38 | 0.00 |
| June | 4043.66 | 09-JUN-16:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1006.80 | 0.00 |
| July | 4124.00 | 21-JUL-14:00 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 942.38 | 0.00 |
| August | 4201.80 | 16-AUG-12:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 1068.08 | 0.00 |
| September | 3541.03 | 05-SEP-14:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 686.38 | 0.00 |
| October | 3063.22 | 19-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 866.25 | 0.00 |
| November | 2336.20 | 01-NOV-14:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 394.83 | 0.00 |
| December | 1643.65 | 10-DEC-13:30 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 177.86 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1406.94 | 59.38 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 154.41 | 0.00 | |
| Maximum of Months | 5352.40 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 2652.38 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1095.98 | 23-JAN-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 79.42 | 0.00 |
| February | 1633.44 | 06-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 220.88 | 0.00 |
| March | 2180.80 | 27-MAR-16:01 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 311.11 | 0.00 |
| April | 2564.61 | 28-APR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 579.18 | 0.00 |
| May | 3647.79 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
| June | 3070.43 | 09-JUN-16:17 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 600.82 | 0.00 |
| July | 3108.42 | 21-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 513.19 | 0.00 |
| August | 2997.39 | 04-AUG-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 601.18 | 0.00 |
| September | 2702.16 | 04-SEP-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 373.31 | 0.00 |
| October | 2293.24 | 19-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 522.50 | 0.00 |
| November | 1783.48 | 01-NOV-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 224.73 | 0.00 |
| December | 1302.99 | 10-DEC-13:40 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 106.15 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1095.98 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 79.42 | 0.00 | |
| Maximum of Months | 3647.79 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1096.56 | 23-JAN-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 79.42 | 0.00 |
| February | 1630.76 | 06-FEB-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 220.88 | 0.00 |
| March | 2174.96 | 27-MAR-16:01 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 311.11 | 0.00 |
| April | 2574.37 | 28-APR-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 579.18 | 0.00 |
| May | 3656.30 | 21-MAY-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
| June | 3061.95 | 09-JUN-16:17 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 600.82 | 0.00 |
| July | 3102.50 | 21-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 513.19 | 0.00 |
| August | 3006.34 | 04-AUG-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 601.18 | 0.00 |
| September | 2694.98 | 04-SEP-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 373.31 | 0.00 |
| October | 2289.33 | 19-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 522.50 | 0.00 |
| November | 1781.25 | 01-NOV-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 224.73 | 0.00 |
| December | 1305.60 | 10-DEC-13:40 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 106.15 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1096.56 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 79.42 | 0.00 | |
| Maximum of Months | 3656.30 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1857.27 | 28-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 53.59 | 0.00 |
| February | 2458.21 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 228.65 | 0.00 |
| March | 2647.87 | 01-MAR-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 433.26 | 0.00 |
| April | 2776.69 | 28-APR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 579.18 | 0.00 |
| May | 3717.61 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
| June | 2989.74 | 09-JUN-16:02 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 607.27 | 0.00 |
| July | 3118.76 | 30-JUL-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 556.42 | 0.00 |
| August | 3135.37 | 16-AUG-12:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 644.24 | 0.00 |
| September | 3058.10 | 04-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 401.82 | 0.00 |
| October | 3004.76 | 09-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 321.49 | 0.00 |
| November | 2622.12 | 05-NOV-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 191.49 | 0.00 |
| December | 2201.15 | 03-DEC-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 70.47 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1857.27 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 53.59 | 0.00 | |
| Maximum of Months | 3717.61 | 237.50 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1862.71 | 28-JAN-14:20 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 52.17 | 0.00 |
| February | 2463.42 | 05-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 228.65 | 0.00 |
| March | 2643.60 | 01-MAR-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 433.26 | 0.00 |
| April | 2786.47 | 28-APR-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 579.18 | 0.00 |
| May | 3726.12 | 21-MAY-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
| June | 2981.87 | 09-JUN-16:02 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 607.27 | 0.00 |
| July | 3120.16 | 30-JUL-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 553.20 | 0.00 |
| August | 3146.29 | 16-AUG-12:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 644.24 | 0.00 |
| September | 3061.33 | 04-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 401.82 | 0.00 |
| October | 3006.32 | 09-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 321.49 | 0.00 |
| November | 2626.52 | 05-NOV-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 191.49 | 0.00 |
| December | 2204.74 | 03-DEC-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 70.47 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1862.71 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 52.17 | 0.00 | |
| Maximum of Months | 3726.12 | 118.75 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 1600.09 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.41 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.70 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.80 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.73 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 | 0.00 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.49 | 0.00 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.07 | 0.00 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.59 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.61 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.20 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.10 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.59 | 18.70 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.68 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.14 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.89 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.21 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 | 0.00 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 4.31 | 0.00 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 4.64 | 0.00 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 12.75 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 2.02 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.52 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 12.75 | 11.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.12 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.47 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.25 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.59 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.36 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.48 | 0.00 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.56 | 0.00 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.37 | 0.00 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.91 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.35 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.51 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.18 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.91 | 15.47 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.103965E+12 | 76300.15 | 07-JAN-18:30 | 6928710.41 | 524.31 | 20-JAN-06:00 |
| February | 0.981278E+11 | 83418.40 | 07-FEB-17:30 | 33176.21 | 55.29 | 13-FEB-08:00 |
| March | 0.114794E+12 | 84925.41 | 27-MAR-16:19 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 0.122589E+12 | 95768.30 | 28-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 0.147504E+12 | 103164.16 | 31-MAY-16:30 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 0.156680E+12 | 106210.59 | 09-JUN-16:00 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 0.175744E+12 | 114674.51 | 30-JUL-17:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 0.180869E+12 | 113253.31 | 22-AUG-17:40 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 0.160887E+12 | 106333.28 | 07-SEP-16:19 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 0.148092E+12 | 98557.47 | 01-OCT-17:30 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 0.125303E+12 | 92497.40 | 01-NOV-17:49 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 0.111467E+12 | 86051.48 | 05-DEC-17:40 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.164602E+13 | 6961886.63 | ||||
| Minimum of Months | 0.981278E+11 | 76300.15 | 0.00 | 0.00 | ||
| Maximum of Months | 0.180869E+12 | 114674.51 | 6928710.41 | 524.31 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.474635E+10 | 0.389380E+11 | 0.00 | 0.785136E+10 | 0.00 | 0.00 | 0.117911E+11 | 0.00 | 0.00 | 0.00 | 0.322288E+11 | 0.00 |
| February | 0.760941E+10 | 0.411796E+10 | 0.351823E+11 | 0.00 | 0.808599E+10 | 0.00 | 0.00 | 0.146060E+11 | 0.00 | 0.00 | 0.00 | 0.285262E+11 | 0.00 |
| March | 0.845392E+10 | 0.431278E+10 | 0.389781E+11 | 0.00 | 0.105400E+11 | 0.00 | 0.00 | 0.224786E+11 | 0.00 | 0.00 | 0.00 | 0.300303E+11 | 0.00 |
| April | 0.814762E+10 | 0.391168E+10 | 0.376905E+11 | 0.00 | 0.128731E+11 | 0.00 | 0.00 | 0.329275E+11 | 0.00 | 0.00 | 0.00 | 0.270386E+11 | 0.00 |
| May | 0.843904E+10 | 0.383146E+10 | 0.389647E+11 | 0.00 | 0.174278E+11 | 0.00 | 0.00 | 0.529467E+11 | 0.00 | 0.00 | 0.00 | 0.258941E+11 | 0.00 |
| June | 0.817737E+10 | 0.360990E+10 | 0.377173E+11 | 0.00 | 0.195101E+11 | 0.00 | 0.00 | 0.640250E+11 | 0.00 | 0.00 | 0.00 | 0.236402E+11 | 0.00 |
| July | 0.840929E+10 | 0.376652E+10 | 0.389380E+11 | 0.00 | 0.225281E+11 | 0.00 | 0.00 | 0.781342E+11 | 0.00 | 0.00 | 0.00 | 0.239675E+11 | 0.00 |
| August | 0.845392E+10 | 0.394797E+10 | 0.389781E+11 | 0.00 | 0.231961E+11 | 0.00 | 0.00 | 0.816687E+11 | 0.00 | 0.00 | 0.00 | 0.246243E+11 | 0.00 |
| September | 0.814762E+10 | 0.405875E+10 | 0.376905E+11 | 0.00 | 0.198704E+11 | 0.00 | 0.00 | 0.657443E+11 | 0.00 | 0.00 | 0.00 | 0.253753E+11 | 0.00 |
| October | 0.842417E+10 | 0.445412E+10 | 0.389514E+11 | 0.00 | 0.170395E+11 | 0.00 | 0.00 | 0.509129E+11 | 0.00 | 0.00 | 0.00 | 0.283099E+11 | 0.00 |
| November | 0.814762E+10 | 0.453434E+10 | 0.376905E+11 | 0.00 | 0.128102E+11 | 0.00 | 0.00 | 0.327385E+11 | 0.00 | 0.00 | 0.00 | 0.293815E+11 | 0.00 |
| December | 0.840929E+10 | 0.481319E+10 | 0.389380E+11 | 0.00 | 0.944626E+10 | 0.00 | 0.00 | 0.180637E+11 | 0.00 | 0.00 | 0.00 | 0.317964E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.501050E+11 | 0.458657E+12 | 0.00 | 0.181179E+12 | 0.00 | 0.00 | 0.526037E+12 | 0.00 | 0.00 | 0.00 | 0.330813E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.360990E+10 | 0.351823E+11 | 0.00 | 0.785136E+10 | 0.00 | 0.00 | 0.117911E+11 | 0.00 | 0.00 | 0.00 | 0.236402E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.481319E+10 | 0.389781E+11 | 0.00 | 0.231961E+11 | 0.00 | 0.00 | 0.816687E+11 | 0.00 | 0.00 | 0.00 | 0.322288E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 6928710.41 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 33176.21 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 6961886.63 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 6928710.41 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 5499.52 | 29-JAN-16:10 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 6837.54 | 05-FEB-15:09 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 7964.16 | 01-MAR-15:20 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 9026.81 | 28-APR-15:09 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 11711.50 | 21-MAY-12:00 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 11178.49 | 09-JUN-14:20 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 11930.09 | 30-JUL-16:30 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 12556.76 | 10-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 11047.31 | 09-SEP-16:10 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 9797.72 | 07-OCT-16:10 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 8801.11 | 01-NOV-14:09 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 6204.71 | 05-DEC-16:10 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 5499.52 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 12556.76 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 14192.86 | 29-JAN-16:10 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 37007.56 | 01-JAN-07:10 | 0.00 |
| February | 20808.84 | 07-FEB-16:10 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 32479.02 | 03-FEB-07:19 | 0.00 |
| March | 26283.31 | 27-MAR-12:50 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 32273.32 | 30-MAR-06:10 | 0.00 |
| April | 31925.26 | 28-APR-15:09 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 36546.07 | 28-APR-06:00 | 0.00 |
| May | 42935.25 | 21-MAY-12:00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 32208.20 | 11-MAY-06:00 | 0.00 |
| June | 43917.40 | 09-JUN-14:20 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 31919.69 | 09-JUN-06:49 | 0.00 |
| July | 47561.57 | 14-JUL-13:00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 32733.23 | 29-JUL-07:19 | 0.00 |
| August | 50379.87 | 10-AUG-15:00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 31144.37 | 01-AUG-07:40 | 0.00 |
| September | 41853.59 | 08-SEP-15:09 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 33871.68 | 29-SEP-05:49 | 0.00 |
| October | 34933.49 | 07-OCT-14:09 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 35896.12 | 28-OCT-05:40 | 0.00 |
| November | 31163.48 | 01-NOV-14:09 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 36642.41 | 29-NOV-07:19 | 0.00 |
| December | 18257.22 | 05-DEC-16:10 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 35492.12 | 11-DEC-07:10 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 14192.86 | 0.00 | 0.00 | 0.00 | 31144.37 | 0.00 | |||
| Maximum of Months | 50379.87 | 0.00 | 0.00 | 0.00 | 37007.56 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 76300.15 | 07-JAN-18:30 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 3943.57 | 0.00 | 0.00 | 8028.89 | 0.00 |
| February | 83418.40 | 07-FEB-17:30 | 4289.87 | 22709.69 | 0.00 | 0.00 | 6328.26 | 0.00 | 0.00 | 18073.52 | 0.00 |
| March | 84925.41 | 27-MAR-16:19 | 4289.87 | 22709.69 | 0.00 | 0.00 | 7692.87 | 0.00 | 0.00 | 24259.05 | 0.00 |
| April | 95768.30 | 28-APR-16:10 | 4289.87 | 22709.69 | 0.00 | 0.00 | 8569.90 | 0.00 | 0.00 | 28437.34 | 0.00 |
| May | 103164.16 | 31-MAY-16:30 | 4289.87 | 22709.69 | 0.00 | 0.00 | 9949.23 | 0.00 | 0.00 | 36292.91 | 0.00 |
| June | 106210.59 | 09-JUN-16:00 | 4289.87 | 22709.69 | 0.00 | 0.00 | 10960.76 | 0.00 | 0.00 | 41141.40 | 0.00 |
| July | 114674.51 | 30-JUL-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 11797.74 | 0.00 | 0.00 | 45004.43 | 0.00 |
| August | 113253.31 | 22-AUG-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 11808.23 | 0.00 | 0.00 | 44749.80 | 0.00 |
| September | 106333.28 | 07-SEP-16:19 | 4289.87 | 22709.69 | 0.00 | 0.00 | 10505.06 | 0.00 | 0.00 | 38677.31 | 0.00 |
| October | 98557.47 | 01-OCT-17:30 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8763.01 | 0.00 | 0.00 | 29987.41 | 0.00 |
| November | 92497.40 | 01-NOV-17:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 7764.01 | 0.00 | 0.00 | 24678.87 | 0.00 |
| December | 86051.48 | 05-DEC-17:40 | 4289.87 | 22709.69 | 3183.33 | 0.00 | 5748.08 | 0.00 | 0.00 | 15451.09 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 76300.15 | 4289.87 | 22609.62 | 0.00 | 0.00 | 3943.57 | 0.00 | 0.00 | 8028.89 | 0.00 | |
| Maximum of Months | 114674.51 | 5231.74 | 22709.69 | 3183.33 | 0.00 | 11808.23 | 0.00 | 0.00 | 45004.43 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 524.31 | 20-JAN-06:00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 55.29 | 13-FEB-08:00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 524.31 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.16 | 0.17 | 26.16 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.17 | 26.16 | 0.17 | 26.16 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.16 | 0.17 | 26.16 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 13.33 | 23.90 | 223.50 | 23.99 | 0.00 | 23.99 |
| February | 2.50 | 23.81 | 310.83 | 24.00 | 0.00 | 24.00 |
| March | 6.67 | 23.84 | 272.17 | 24.00 | 2.00 | 24.00 |
| April | 23.50 | 24.00 | 437.83 | 24.00 | 23.50 | 24.00 |
| May | 66.33 | 24.00 | 501.83 | 24.00 | 66.33 | 24.00 |
| June | 186.33 | 24.00 | 492.00 | 24.00 | 186.33 | 24.00 |
| July | 271.50 | 24.00 | 533.00 | 24.00 | 271.50 | 24.00 |
| August | 222.33 | 24.00 | 506.00 | 24.00 | 222.33 | 24.00 |
| September | 169.33 | 24.00 | 510.00 | 24.00 | 169.33 | 24.00 |
| October | 82.67 | 24.00 | 521.00 | 24.00 | 82.67 | 24.00 |
| November | 1.33 | 24.00 | 510.00 | 24.00 | 1.33 | 24.00 |
| December | 2.00 | 24.00 | 409.33 | 24.00 | 2.00 | 24.00 |
| Annual Sum or Average | 1047.83 | 24.00 | 5227.50 | 24.00 | 1027.33 | 24.00 |
| Minimum of Months | 1.33 | 23.81 | 223.50 | 23.99 | 0.00 | 23.99 |
| Maximum of Months | 271.50 | 24.00 | 533.00 | 24.00 | 271.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 64.33 | 23.80 | 233.50 | 23.96 | 0.67 | 23.96 |
| February | 16.17 | 23.75 | 360.17 | 23.99 | 2.67 | 23.99 |
| March | 27.33 | 23.89 | 330.33 | 23.99 | 7.67 | 23.99 |
| April | 29.00 | 24.00 | 574.50 | 24.00 | 29.00 | 24.00 |
| May | 72.50 | 24.00 | 714.33 | 24.00 | 72.50 | 24.00 |
| June | 218.33 | 24.00 | 720.00 | 24.00 | 218.33 | 24.00 |
| July | 358.67 | 24.00 | 744.00 | 24.00 | 358.67 | 24.00 |
| August | 309.50 | 24.00 | 744.00 | 24.00 | 309.50 | 24.00 |
| September | 235.67 | 24.00 | 720.00 | 24.00 | 235.67 | 24.00 |
| October | 110.17 | 24.00 | 732.17 | 24.00 | 110.17 | 24.00 |
| November | 3.17 | 24.00 | 709.67 | 24.00 | 3.17 | 24.00 |
| December | 9.67 | 24.00 | 488.00 | 24.00 | 9.50 | 24.00 |
| Annual Sum or Average | 1454.50 | 23.99 | 7070.67 | 24.00 | 1357.50 | 24.00 |
| Minimum of Months | 3.17 | 23.75 | 233.50 | 23.96 | 0.67 | 23.96 |
| Maximum of Months | 358.67 | 24.00 | 744.00 | 24.00 | 358.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 140.00 | 24.23 | 0.00 | 24.23 |
| February | 1.33 | 25.70 | 133.00 | 24.24 | 1.33 | 24.26 |
| March | 2.50 | 25.62 | 161.00 | 24.25 | 2.50 | 24.27 |
| April | 4.67 | 25.65 | 140.00 | 24.28 | 4.67 | 24.32 |
| May | 13.00 | 25.58 | 154.00 | 24.34 | 13.00 | 24.43 |
| June | 24.50 | 25.39 | 154.00 | 24.40 | 24.50 | 24.52 |
| July | 30.83 | 25.12 | 140.00 | 24.41 | 30.83 | 24.52 |
| August | 31.33 | 25.28 | 161.00 | 24.42 | 31.33 | 24.54 |
| September | 22.33 | 25.51 | 140.00 | 24.42 | 22.33 | 24.55 |
| October | 21.50 | 25.55 | 147.00 | 24.41 | 21.50 | 24.54 |
| November | 14.67 | 25.65 | 140.00 | 24.37 | 14.67 | 24.48 |
| December | 2.00 | 25.66 | 140.00 | 24.25 | 2.00 | 24.27 |
| Annual Sum or Average | 168.67 | 25.41 | 1750.00 | 24.34 | 168.67 | 24.43 |
| Minimum of Months | 0.00 | 0.00 | 133.00 | 24.23 | 0.00 | 24.23 |
| Maximum of Months | 31.33 | 25.70 | 161.00 | 24.42 | 31.33 | 24.55 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 55.67 | 23.79 | 238.17 | 23.96 | 0.67 | 23.96 |
| February | 14.00 | 23.77 | 349.33 | 23.99 | 3.17 | 23.99 |
| March | 26.50 | 23.88 | 322.00 | 23.99 | 8.33 | 23.99 |
| April | 30.50 | 24.00 | 582.50 | 24.00 | 30.50 | 24.00 |
| May | 73.67 | 24.00 | 732.00 | 24.00 | 73.67 | 24.00 |
| June | 218.00 | 24.00 | 720.00 | 24.00 | 218.00 | 24.00 |
| July | 359.17 | 24.00 | 744.00 | 24.00 | 359.17 | 24.00 |
| August | 314.67 | 24.00 | 744.00 | 24.00 | 314.67 | 24.00 |
| September | 240.50 | 24.00 | 720.00 | 24.00 | 240.50 | 24.00 |
| October | 108.83 | 24.00 | 730.83 | 24.00 | 108.83 | 24.00 |
| November | 2.67 | 24.00 | 710.83 | 24.00 | 2.67 | 24.00 |
| December | 9.00 | 24.00 | 495.83 | 24.00 | 9.00 | 24.00 |
| Annual Sum or Average | 1453.17 | 23.99 | 7089.50 | 24.00 | 1369.17 | 24.00 |
| Minimum of Months | 2.67 | 23.77 | 238.17 | 23.96 | 0.67 | 23.96 |
| Maximum of Months | 359.17 | 24.00 | 744.00 | 24.00 | 359.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 23.67 | 23.95 | 209.50 | 23.99 | 0.83 | 23.99 |
| February | 0.50 | 23.71 | 338.67 | 24.00 | 0.00 | 24.00 |
| March | 13.67 | 23.98 | 292.33 | 24.00 | 6.50 | 24.00 |
| April | 27.50 | 24.00 | 542.83 | 24.00 | 27.50 | 24.00 |
| May | 83.50 | 24.00 | 686.00 | 24.00 | 83.50 | 24.00 |
| June | 246.83 | 24.00 | 717.17 | 24.00 | 246.83 | 24.00 |
| July | 395.67 | 24.00 | 744.00 | 24.00 | 395.67 | 24.00 |
| August | 361.50 | 24.00 | 744.00 | 24.00 | 361.50 | 24.00 |
| September | 290.67 | 24.00 | 720.00 | 24.00 | 290.67 | 24.00 |
| October | 125.83 | 24.00 | 717.67 | 24.00 | 125.83 | 24.00 |
| November | 8.00 | 24.00 | 694.50 | 24.00 | 8.00 | 24.00 |
| December | 9.00 | 24.00 | 459.33 | 24.00 | 9.00 | 24.00 |
| Annual Sum or Average | 1586.33 | 24.00 | 6866.00 | 24.00 | 1555.83 | 24.00 |
| Minimum of Months | 0.50 | 23.71 | 209.50 | 23.99 | 0.00 | 23.99 |
| Maximum of Months | 395.67 | 24.00 | 744.00 | 24.00 | 395.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 23.17 | 23.94 | 210.17 | 23.99 | 0.83 | 23.99 |
| February | 0.50 | 23.71 | 338.83 | 24.00 | 0.00 | 24.00 |
| March | 13.33 | 23.98 | 291.83 | 24.00 | 6.33 | 24.00 |
| April | 27.50 | 24.00 | 543.00 | 24.00 | 27.50 | 24.00 |
| May | 83.33 | 24.00 | 686.33 | 24.00 | 83.33 | 24.00 |
| June | 246.83 | 24.00 | 717.17 | 24.00 | 246.83 | 24.00 |
| July | 395.33 | 24.00 | 744.00 | 24.00 | 395.33 | 24.00 |
| August | 361.50 | 24.00 | 744.00 | 24.00 | 361.50 | 24.00 |
| September | 290.67 | 24.00 | 720.00 | 24.00 | 290.67 | 24.00 |
| October | 125.83 | 24.00 | 717.83 | 24.00 | 125.83 | 24.00 |
| November | 8.00 | 24.00 | 694.33 | 24.00 | 8.00 | 24.00 |
| December | 9.33 | 24.00 | 459.50 | 24.00 | 9.33 | 24.00 |
| Annual Sum or Average | 1585.33 | 24.00 | 6867.00 | 24.00 | 1555.50 | 24.00 |
| Minimum of Months | 0.50 | 23.71 | 210.17 | 23.99 | 0.00 | 23.99 |
| Maximum of Months | 395.33 | 24.00 | 744.00 | 24.00 | 395.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 1.50 | 24.00 | 242.33 | 24.00 | 0.00 | 24.00 |
| February | 0.00 | 0.00 | 318.00 | 24.00 | 0.00 | 24.00 |
| March | 2.17 | 24.00 | 271.17 | 24.00 | 1.00 | 24.00 |
| April | 19.00 | 24.00 | 423.00 | 24.00 | 19.00 | 24.00 |
| May | 74.67 | 24.00 | 485.67 | 24.00 | 74.67 | 24.00 |
| June | 211.83 | 24.00 | 492.00 | 24.00 | 211.83 | 24.00 |
| July | 295.67 | 24.00 | 533.00 | 24.00 | 295.67 | 24.00 |
| August | 257.00 | 24.00 | 506.00 | 24.00 | 257.00 | 24.00 |
| September | 213.83 | 24.00 | 510.00 | 24.00 | 213.83 | 24.00 |
| October | 93.67 | 24.00 | 516.17 | 24.00 | 93.67 | 24.00 |
| November | 1.33 | 24.00 | 508.00 | 24.00 | 1.33 | 24.00 |
| December | 1.17 | 24.00 | 411.67 | 24.00 | 1.17 | 24.00 |
| Annual Sum or Average | 1171.83 | 24.00 | 5217.00 | 24.00 | 1169.17 | 24.00 |
| Minimum of Months | 0.00 | 0.00 | 242.33 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 295.67 | 24.00 | 533.00 | 24.00 | 295.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 280.67 | 24.00 | 0.00 | 24.00 |
| February | 0.00 | 0.00 | 342.67 | 24.00 | 0.00 | 24.00 |
| March | 0.00 | 0.00 | 316.17 | 24.00 | 0.00 | 24.00 |
| April | 9.17 | 24.00 | 444.67 | 24.00 | 9.17 | 24.00 |
| May | 53.50 | 24.00 | 502.67 | 24.00 | 53.50 | 24.00 |
| June | 182.33 | 24.00 | 492.00 | 24.00 | 182.33 | 24.00 |
| July | 271.67 | 24.00 | 533.00 | 24.00 | 271.67 | 24.00 |
| August | 228.67 | 24.00 | 506.00 | 24.00 | 228.67 | 24.00 |
| September | 166.17 | 24.00 | 510.00 | 24.00 | 166.17 | 24.00 |
| October | 79.33 | 24.00 | 520.50 | 24.00 | 79.33 | 24.00 |
| November | 1.17 | 24.00 | 508.83 | 24.00 | 1.17 | 24.00 |
| December | 0.00 | 0.00 | 437.33 | 24.00 | 0.00 | 24.00 |
| Annual Sum or Average | 992.00 | 24.00 | 5394.50 | 24.00 | 992.00 | 24.00 |
| Minimum of Months | 0.00 | 0.00 | 280.67 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 271.67 | 24.00 | 533.00 | 24.00 | 271.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 52.83 | 23.73 | 168.67 | 23.94 | 0.00 | 23.94 |
| February | 13.00 | 23.76 | 275.33 | 23.99 | 3.33 | 23.99 |
| March | 8.83 | 23.87 | 259.17 | 24.00 | 2.83 | 24.00 |
| April | 22.33 | 24.00 | 424.00 | 24.00 | 22.33 | 24.00 |
| May | 71.17 | 24.00 | 482.33 | 24.00 | 71.17 | 24.00 |
| June | 205.83 | 24.00 | 492.00 | 24.00 | 205.83 | 24.00 |
| July | 314.00 | 24.00 | 526.17 | 24.00 | 314.00 | 24.00 |
| August | 275.50 | 24.00 | 506.00 | 24.00 | 275.50 | 24.00 |
| September | 280.17 | 24.00 | 510.00 | 24.00 | 280.17 | 24.00 |
| October | 135.17 | 24.00 | 503.67 | 24.00 | 135.17 | 24.00 |
| November | 23.33 | 24.00 | 466.33 | 24.00 | 23.33 | 24.00 |
| December | 12.33 | 23.94 | 320.50 | 23.99 | 8.00 | 24.00 |
| Annual Sum or Average | 1414.50 | 23.99 | 4934.17 | 24.00 | 1341.67 | 24.00 |
| Minimum of Months | 8.83 | 23.73 | 168.67 | 23.94 | 0.00 | 23.94 |
| Maximum of Months | 314.00 | 24.00 | 526.17 | 24.00 | 314.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 162.83 | 23.70 | 157.50 | 23.85 | 1.83 | 23.85 |
| February | 41.33 | 23.71 | 313.50 | 23.96 | 7.17 | 23.97 |
| March | 26.33 | 23.93 | 329.33 | 23.99 | 9.33 | 23.99 |
| April | 28.50 | 24.00 | 563.17 | 24.00 | 28.50 | 24.00 |
| May | 80.00 | 24.00 | 686.00 | 24.00 | 80.00 | 24.00 |
| June | 247.33 | 24.00 | 718.00 | 24.00 | 247.33 | 24.00 |
| July | 415.83 | 24.00 | 736.33 | 24.00 | 415.83 | 24.00 |
| August | 393.83 | 24.00 | 744.00 | 24.00 | 393.83 | 24.00 |
| September | 371.33 | 24.00 | 720.00 | 24.00 | 371.33 | 24.00 |
| October | 202.00 | 24.00 | 696.50 | 24.00 | 202.00 | 24.00 |
| November | 59.50 | 24.00 | 626.00 | 24.00 | 59.50 | 24.00 |
| December | 63.00 | 23.89 | 400.17 | 23.98 | 33.33 | 23.98 |
| Annual Sum or Average | 2091.83 | 23.97 | 6690.50 | 23.99 | 1850.00 | 23.99 |
| Minimum of Months | 26.33 | 23.70 | 157.50 | 23.85 | 1.83 | 23.85 |
| Maximum of Months | 415.83 | 24.00 | 744.00 | 24.00 | 415.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 52.17 | 23.73 | 171.00 | 23.94 | 0.00 | 23.94 |
| February | 14.33 | 23.77 | 274.83 | 23.99 | 3.67 | 23.99 |
| March | 8.67 | 23.88 | 263.00 | 24.00 | 3.00 | 24.00 |
| April | 24.83 | 24.00 | 433.17 | 24.00 | 24.83 | 24.00 |
| May | 72.00 | 24.00 | 491.17 | 24.00 | 72.00 | 24.00 |
| June | 213.83 | 24.00 | 492.00 | 24.00 | 213.83 | 24.00 |
| July | 317.67 | 24.00 | 526.17 | 24.00 | 317.67 | 24.00 |
| August | 284.17 | 24.00 | 506.00 | 24.00 | 284.17 | 24.00 |
| September | 292.33 | 24.00 | 510.00 | 24.00 | 292.33 | 24.00 |
| October | 136.33 | 24.00 | 504.67 | 24.00 | 136.33 | 24.00 |
| November | 23.67 | 24.00 | 471.33 | 24.00 | 23.67 | 24.00 |
| December | 11.33 | 23.93 | 318.67 | 23.99 | 7.17 | 24.00 |
| Annual Sum or Average | 1451.33 | 23.99 | 4962.00 | 24.00 | 1378.67 | 24.00 |
| Minimum of Months | 8.67 | 23.73 | 171.00 | 23.94 | 0.00 | 23.94 |
| Maximum of Months | 317.67 | 24.00 | 526.17 | 24.00 | 317.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 152.00 | 23.73 | 158.50 | 23.87 | 1.67 | 23.87 |
| February | 34.00 | 23.70 | 310.00 | 23.97 | 7.17 | 23.97 |
| March | 24.67 | 23.93 | 317.00 | 24.00 | 9.00 | 24.00 |
| April | 30.17 | 24.00 | 570.50 | 24.00 | 30.17 | 24.00 |
| May | 79.17 | 24.00 | 701.83 | 24.00 | 79.17 | 24.00 |
| June | 247.83 | 24.00 | 718.67 | 24.00 | 247.83 | 24.00 |
| July | 418.17 | 24.00 | 737.00 | 24.00 | 418.17 | 24.00 |
| August | 396.83 | 24.00 | 744.00 | 24.00 | 396.83 | 24.00 |
| September | 377.50 | 24.00 | 720.00 | 24.00 | 377.50 | 24.00 |
| October | 197.33 | 24.00 | 705.00 | 24.00 | 197.33 | 24.00 |
| November | 57.50 | 24.00 | 623.83 | 24.00 | 57.50 | 24.00 |
| December | 60.00 | 23.91 | 394.83 | 23.98 | 37.67 | 23.98 |
| Annual Sum or Average | 2075.17 | 23.97 | 6701.17 | 23.99 | 1860.00 | 23.99 |
| Minimum of Months | 24.67 | 23.70 | 158.50 | 23.87 | 1.67 | 23.87 |
| Maximum of Months | 418.17 | 24.00 | 744.00 | 24.00 | 418.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 85.67 | 23.91 | 146.67 | 23.97 | 1.67 | 23.97 |
| February | 9.67 | 23.89 | 293.83 | 24.00 | 4.50 | 24.00 |
| March | 18.00 | 23.98 | 274.67 | 24.00 | 6.83 | 24.00 |
| April | 26.50 | 24.00 | 520.00 | 24.00 | 26.50 | 24.00 |
| May | 89.33 | 24.00 | 657.00 | 24.00 | 89.33 | 24.00 |
| June | 277.83 | 24.00 | 701.17 | 24.00 | 277.83 | 24.00 |
| July | 433.83 | 24.00 | 731.67 | 24.00 | 433.83 | 24.00 |
| August | 430.83 | 24.00 | 744.00 | 24.00 | 430.83 | 24.00 |
| September | 411.17 | 24.00 | 718.67 | 24.00 | 411.17 | 24.00 |
| October | 209.50 | 24.00 | 681.67 | 24.00 | 209.50 | 24.00 |
| November | 51.50 | 24.00 | 606.00 | 24.00 | 51.50 | 24.00 |
| December | 29.00 | 23.99 | 377.67 | 24.00 | 27.50 | 24.00 |
| Annual Sum or Average | 2072.83 | 24.00 | 6453.00 | 24.00 | 1971.00 | 24.00 |
| Minimum of Months | 9.67 | 23.89 | 146.67 | 23.97 | 1.67 | 23.97 |
| Maximum of Months | 433.83 | 24.00 | 744.00 | 24.00 | 433.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 85.00 | 23.91 | 146.50 | 23.97 | 1.67 | 23.97 |
| February | 9.67 | 23.89 | 293.83 | 24.00 | 4.50 | 24.00 |
| March | 18.00 | 23.98 | 274.33 | 24.00 | 6.83 | 24.00 |
| April | 26.50 | 24.00 | 520.33 | 24.00 | 26.50 | 24.00 |
| May | 89.33 | 24.00 | 657.00 | 24.00 | 89.33 | 24.00 |
| June | 277.83 | 24.00 | 701.17 | 24.00 | 277.83 | 24.00 |
| July | 433.33 | 24.00 | 731.67 | 24.00 | 433.33 | 24.00 |
| August | 430.50 | 24.00 | 744.00 | 24.00 | 430.50 | 24.00 |
| September | 411.67 | 24.00 | 718.67 | 24.00 | 411.67 | 24.00 |
| October | 209.67 | 24.00 | 681.83 | 24.00 | 209.67 | 24.00 |
| November | 51.67 | 24.00 | 606.33 | 24.00 | 51.67 | 24.00 |
| December | 28.83 | 23.99 | 378.00 | 24.00 | 27.50 | 24.00 |
| Annual Sum or Average | 2072.00 | 24.00 | 6453.67 | 24.00 | 1971.00 | 24.00 |
| Minimum of Months | 9.67 | 23.89 | 146.50 | 23.97 | 1.67 | 23.97 |
| Maximum of Months | 433.33 | 24.00 | 744.00 | 24.00 | 433.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 12.17 | 23.95 | 180.33 | 24.00 | 0.00 | 24.00 |
| February | 0.00 | 0.00 | 279.00 | 24.00 | 0.00 | 24.00 |
| March | 4.33 | 23.97 | 247.17 | 24.00 | 1.83 | 24.00 |
| April | 17.83 | 24.00 | 400.00 | 24.00 | 17.83 | 24.00 |
| May | 82.00 | 24.00 | 470.17 | 24.00 | 82.00 | 24.00 |
| June | 236.83 | 24.00 | 489.33 | 24.00 | 236.83 | 24.00 |
| July | 329.00 | 24.00 | 522.33 | 24.00 | 329.00 | 24.00 |
| August | 302.17 | 24.00 | 506.00 | 24.00 | 302.17 | 24.00 |
| September | 310.50 | 24.00 | 510.00 | 24.00 | 310.50 | 24.00 |
| October | 138.50 | 24.00 | 500.50 | 24.00 | 138.50 | 24.00 |
| November | 15.17 | 24.00 | 465.67 | 24.00 | 15.17 | 24.00 |
| December | 4.50 | 24.00 | 328.67 | 24.00 | 4.50 | 24.00 |
| Annual Sum or Average | 1453.00 | 24.00 | 4899.17 | 24.00 | 1438.33 | 24.00 |
| Minimum of Months | 0.00 | 0.00 | 180.33 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 329.00 | 24.00 | 522.33 | 24.00 | 329.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 12.17 | 23.95 | 180.17 | 24.00 | 0.00 | 24.00 |
| February | 0.00 | 0.00 | 279.17 | 24.00 | 0.00 | 24.00 |
| March | 4.33 | 23.97 | 246.83 | 24.00 | 1.83 | 24.00 |
| April | 17.67 | 24.00 | 400.00 | 24.00 | 17.67 | 24.00 |
| May | 82.50 | 24.00 | 470.50 | 24.00 | 82.50 | 24.00 |
| June | 237.00 | 24.00 | 491.00 | 24.00 | 237.00 | 24.00 |
| July | 329.00 | 24.00 | 522.33 | 24.00 | 329.00 | 24.00 |
| August | 302.17 | 24.00 | 506.00 | 24.00 | 302.17 | 24.00 |
| September | 310.67 | 24.00 | 510.00 | 24.00 | 310.67 | 24.00 |
| October | 138.50 | 24.00 | 500.50 | 24.00 | 138.50 | 24.00 |
| November | 15.17 | 24.00 | 466.17 | 24.00 | 15.17 | 24.00 |
| December | 4.50 | 24.00 | 328.83 | 24.00 | 4.50 | 24.00 |
| Annual Sum or Average | 1453.67 | 24.00 | 4901.50 | 24.00 | 1439.00 | 24.00 |
| Minimum of Months | 0.00 | 0.00 | 180.17 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 329.00 | 24.00 | 522.33 | 24.00 | 329.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 258.83 | 22.79 | 126.67 | 23.19 | 0.00 | 23.19 |
| February | 188.50 | 23.09 | 211.17 | 23.57 | 27.67 | 23.59 |
| March | 129.33 | 23.42 | 247.00 | 23.80 | 24.50 | 23.81 |
| April | 80.50 | 23.90 | 414.17 | 23.98 | 65.33 | 23.98 |
| May | 87.67 | 24.00 | 491.33 | 24.00 | 87.67 | 24.00 |
| June | 211.50 | 24.00 | 492.00 | 24.00 | 211.50 | 24.00 |
| July | 300.17 | 24.00 | 527.50 | 24.00 | 300.17 | 24.00 |
| August | 264.83 | 24.00 | 506.00 | 24.00 | 264.83 | 24.00 |
| September | 301.67 | 24.00 | 510.00 | 24.00 | 301.67 | 24.00 |
| October | 169.67 | 24.00 | 509.33 | 24.00 | 169.67 | 24.00 |
| November | 78.17 | 23.85 | 430.50 | 23.98 | 60.00 | 23.98 |
| December | 205.00 | 23.25 | 269.50 | 23.65 | 55.17 | 23.66 |
| Annual Sum or Average | 2275.83 | 23.68 | 4735.17 | 23.89 | 1568.17 | 23.91 |
| Minimum of Months | 78.17 | 22.79 | 126.67 | 23.19 | 0.00 | 23.19 |
| Maximum of Months | 301.67 | 24.00 | 527.50 | 24.00 | 301.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 412.67 | 22.81 | 140.17 | 23.11 | 4.50 | 23.12 |
| February | 270.17 | 23.06 | 291.67 | 23.55 | 46.00 | 23.58 |
| March | 185.67 | 23.44 | 376.17 | 23.81 | 41.33 | 23.82 |
| April | 94.83 | 23.90 | 588.67 | 23.98 | 76.67 | 23.98 |
| May | 96.50 | 24.00 | 716.33 | 24.00 | 96.50 | 24.00 |
| June | 247.17 | 24.00 | 720.00 | 24.00 | 247.17 | 24.00 |
| July | 390.17 | 24.00 | 738.17 | 24.00 | 390.17 | 24.00 |
| August | 363.00 | 24.00 | 744.00 | 24.00 | 363.00 | 24.00 |
| September | 383.83 | 24.00 | 720.00 | 24.00 | 383.83 | 24.00 |
| October | 226.17 | 24.00 | 715.50 | 24.00 | 226.17 | 24.00 |
| November | 126.33 | 23.86 | 601.50 | 23.97 | 100.83 | 23.98 |
| December | 304.33 | 23.23 | 369.33 | 23.62 | 87.67 | 23.63 |
| Annual Sum or Average | 3100.83 | 23.64 | 6721.50 | 23.88 | 2063.83 | 23.90 |
| Minimum of Months | 94.83 | 22.81 | 140.17 | 23.11 | 4.50 | 23.12 |
| Maximum of Months | 412.67 | 24.00 | 744.00 | 24.00 | 390.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 259.83 | 22.81 | 127.33 | 23.20 | 0.00 | 23.20 |
| February | 190.50 | 23.10 | 212.00 | 23.57 | 29.50 | 23.60 |
| March | 132.33 | 23.44 | 244.67 | 23.80 | 28.00 | 23.81 |
| April | 82.83 | 23.90 | 417.50 | 23.98 | 68.67 | 23.98 |
| May | 91.33 | 24.00 | 492.67 | 24.00 | 91.33 | 24.00 |
| June | 219.67 | 24.00 | 492.00 | 24.00 | 219.67 | 24.00 |
| July | 305.50 | 24.00 | 528.00 | 24.00 | 305.50 | 24.00 |
| August | 274.00 | 24.00 | 506.00 | 24.00 | 274.00 | 24.00 |
| September | 317.50 | 24.00 | 510.00 | 24.00 | 317.50 | 24.00 |
| October | 172.50 | 24.00 | 511.50 | 24.00 | 172.50 | 24.00 |
| November | 82.83 | 23.87 | 430.83 | 23.98 | 65.67 | 23.98 |
| December | 204.83 | 23.26 | 271.17 | 23.65 | 56.00 | 23.67 |
| Annual Sum or Average | 2333.67 | 23.69 | 4743.67 | 23.89 | 1628.33 | 23.91 |
| Minimum of Months | 82.83 | 22.81 | 127.33 | 23.20 | 0.00 | 23.20 |
| Maximum of Months | 317.50 | 24.00 | 528.00 | 24.00 | 317.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 413.50 | 22.87 | 136.00 | 23.15 | 4.17 | 23.16 |
| February | 260.17 | 23.08 | 284.83 | 23.55 | 46.17 | 23.58 |
| March | 182.33 | 23.45 | 380.50 | 23.82 | 44.67 | 23.83 |
| April | 95.33 | 23.90 | 600.33 | 23.98 | 79.17 | 23.98 |
| May | 97.33 | 24.00 | 720.17 | 24.00 | 97.33 | 24.00 |
| June | 246.67 | 24.00 | 720.00 | 24.00 | 246.67 | 24.00 |
| July | 387.67 | 24.00 | 738.83 | 24.00 | 387.67 | 24.00 |
| August | 371.67 | 24.00 | 744.00 | 24.00 | 371.67 | 24.00 |
| September | 391.67 | 24.00 | 720.00 | 24.00 | 391.67 | 24.00 |
| October | 221.50 | 24.00 | 721.50 | 24.00 | 221.50 | 24.00 |
| November | 122.67 | 23.87 | 611.33 | 23.98 | 98.83 | 23.98 |
| December | 301.50 | 23.26 | 367.67 | 23.63 | 94.33 | 23.65 |
| Annual Sum or Average | 3092.00 | 23.66 | 6745.17 | 23.89 | 2083.83 | 23.91 |
| Minimum of Months | 95.33 | 22.87 | 136.00 | 23.15 | 4.17 | 23.16 |
| Maximum of Months | 413.50 | 24.00 | 744.00 | 24.00 | 391.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 395.83 | 23.15 | 111.17 | 23.34 | 3.67 | 23.34 |
| February | 212.83 | 23.28 | 267.00 | 23.68 | 29.83 | 23.70 |
| March | 146.17 | 23.58 | 341.50 | 23.87 | 30.83 | 23.88 |
| April | 74.33 | 23.96 | 567.17 | 23.99 | 64.83 | 23.99 |
| May | 100.67 | 24.00 | 710.83 | 24.00 | 100.67 | 24.00 |
| June | 248.83 | 24.00 | 720.00 | 24.00 | 248.83 | 24.00 |
| July | 393.50 | 24.00 | 736.00 | 24.00 | 393.50 | 24.00 |
| August | 377.33 | 24.00 | 744.00 | 24.00 | 377.33 | 24.00 |
| September | 391.67 | 24.00 | 720.00 | 24.00 | 391.67 | 24.00 |
| October | 224.83 | 24.00 | 708.83 | 24.00 | 224.83 | 24.00 |
| November | 103.33 | 23.93 | 597.33 | 23.99 | 90.17 | 23.99 |
| December | 247.17 | 23.44 | 358.67 | 23.75 | 74.67 | 23.76 |
| Annual Sum or Average | 2916.50 | 23.76 | 6582.50 | 23.93 | 2030.83 | 23.94 |
| Minimum of Months | 74.33 | 23.15 | 111.17 | 23.34 | 3.67 | 23.34 |
| Maximum of Months | 395.83 | 24.00 | 744.00 | 24.00 | 393.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 393.67 | 23.15 | 111.50 | 23.34 | 3.67 | 23.34 |
| February | 212.17 | 23.28 | 266.67 | 23.68 | 29.83 | 23.70 |
| March | 146.67 | 23.58 | 341.67 | 23.87 | 31.50 | 23.88 |
| April | 74.50 | 23.95 | 569.00 | 23.99 | 64.83 | 23.99 |
| May | 101.00 | 24.00 | 711.00 | 24.00 | 101.00 | 24.00 |
| June | 248.67 | 24.00 | 720.00 | 24.00 | 248.67 | 24.00 |
| July | 393.33 | 24.00 | 736.00 | 24.00 | 393.33 | 24.00 |
| August | 377.33 | 24.00 | 744.00 | 24.00 | 377.33 | 24.00 |
| September | 391.67 | 24.00 | 720.00 | 24.00 | 391.67 | 24.00 |
| October | 224.83 | 24.00 | 708.83 | 24.00 | 224.83 | 24.00 |
| November | 104.00 | 23.93 | 597.50 | 23.99 | 90.67 | 23.99 |
| December | 247.17 | 23.44 | 358.50 | 23.75 | 75.00 | 23.76 |
| Annual Sum or Average | 2915.00 | 23.76 | 6584.67 | 23.93 | 2032.33 | 23.94 |
| Minimum of Months | 74.50 | 23.15 | 111.50 | 23.34 | 3.67 | 23.34 |
| Maximum of Months | 393.67 | 24.00 | 744.00 | 24.00 | 393.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 215.17 | 23.11 | 135.00 | 23.45 | 0.00 | 23.45 |
| February | 130.67 | 23.29 | 222.17 | 23.73 | 9.33 | 23.74 |
| March | 90.67 | 23.55 | 243.33 | 23.88 | 14.17 | 23.88 |
| April | 58.33 | 23.96 | 416.83 | 24.00 | 52.50 | 24.00 |
| May | 92.33 | 24.00 | 488.17 | 24.00 | 92.33 | 24.00 |
| June | 216.50 | 24.00 | 492.00 | 24.00 | 216.50 | 24.00 |
| July | 301.50 | 24.00 | 525.67 | 24.00 | 301.50 | 24.00 |
| August | 273.67 | 24.00 | 506.00 | 24.00 | 273.67 | 24.00 |
| September | 301.50 | 24.00 | 510.00 | 24.00 | 301.50 | 24.00 |
| October | 164.67 | 24.00 | 508.50 | 24.00 | 164.67 | 24.00 |
| November | 57.33 | 23.94 | 432.33 | 23.99 | 50.67 | 23.99 |
| December | 140.83 | 23.44 | 280.50 | 23.80 | 34.50 | 23.80 |
| Annual Sum or Average | 2043.17 | 23.80 | 4760.50 | 23.94 | 1511.33 | 23.95 |
| Minimum of Months | 57.33 | 23.11 | 135.00 | 23.45 | 0.00 | 23.45 |
| Maximum of Months | 301.50 | 24.00 | 525.67 | 24.00 | 301.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 215.50 | 23.11 | 135.00 | 23.45 | 0.00 | 23.45 |
| February | 130.83 | 23.28 | 222.50 | 23.73 | 9.33 | 23.74 |
| March | 91.17 | 23.55 | 243.00 | 23.88 | 14.50 | 23.88 |
| April | 59.33 | 23.96 | 417.17 | 23.99 | 53.50 | 24.00 |
| May | 93.50 | 24.00 | 488.33 | 24.00 | 93.50 | 24.00 |
| June | 218.17 | 24.00 | 492.00 | 24.00 | 218.17 | 24.00 |
| July | 302.67 | 24.00 | 525.67 | 24.00 | 302.67 | 24.00 |
| August | 275.00 | 24.00 | 506.00 | 24.00 | 275.00 | 24.00 |
| September | 304.33 | 24.00 | 510.00 | 24.00 | 304.33 | 24.00 |
| October | 165.17 | 24.00 | 508.83 | 24.00 | 165.17 | 24.00 |
| November | 57.67 | 23.94 | 432.17 | 23.99 | 51.00 | 23.99 |
| December | 141.00 | 23.44 | 280.83 | 23.80 | 34.83 | 23.80 |
| Annual Sum or Average | 2054.33 | 23.80 | 4761.50 | 23.94 | 1522.00 | 23.95 |
| Minimum of Months | 57.67 | 23.11 | 135.00 | 23.45 | 0.00 | 23.45 |
| Maximum of Months | 304.33 | 24.00 | 525.67 | 24.00 | 304.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 718.83 | 24.56 | 740.83 | 24.57 | 716.50 | 24.57 |
| February | 649.50 | 25.01 | 672.00 | 25.01 | 649.50 | 25.01 |
| March | 743.83 | 25.50 | 744.00 | 25.50 | 743.83 | 25.50 |
| April | 720.00 | 26.07 | 720.00 | 26.07 | 720.00 | 26.07 |
| May | 744.00 | 26.74 | 744.00 | 26.74 | 744.00 | 26.74 |
| June | 720.00 | 26.95 | 720.00 | 26.95 | 720.00 | 26.95 |
| July | 744.00 | 27.22 | 744.00 | 27.22 | 744.00 | 27.22 |
| August | 744.00 | 27.25 | 744.00 | 27.25 | 744.00 | 27.25 |
| September | 720.00 | 26.87 | 720.00 | 26.87 | 720.00 | 26.87 |
| October | 744.00 | 26.44 | 744.00 | 26.44 | 744.00 | 26.44 |
| November | 720.00 | 25.85 | 720.00 | 25.85 | 720.00 | 25.85 |
| December | 742.17 | 25.06 | 744.00 | 25.06 | 742.17 | 25.06 |
| Annual Sum or Average | 8710.33 | 26.14 | 8756.83 | 26.14 | 8708.00 | 26.14 |
| Minimum of Months | 649.50 | 24.56 | 672.00 | 24.57 | 649.50 | 24.57 |
| Maximum of Months | 744.00 | 27.25 | 744.00 | 27.25 | 744.00 | 27.25 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 238.50 | 24.85 | 637.17 | 25.19 | 190.33 | 25.27 |
| February | 273.50 | 25.39 | 628.33 | 25.49 | 248.00 | 25.55 |
| March | 321.50 | 25.95 | 713.83 | 25.99 | 303.83 | 26.03 |
| April | 531.00 | 26.83 | 715.50 | 26.80 | 529.83 | 26.81 |
| May | 719.67 | 28.00 | 744.00 | 27.98 | 719.67 | 27.99 |
| June | 720.00 | 28.37 | 720.00 | 28.37 | 720.00 | 28.37 |
| July | 744.00 | 28.84 | 744.00 | 28.84 | 744.00 | 28.84 |
| August | 744.00 | 28.99 | 744.00 | 28.99 | 744.00 | 28.99 |
| September | 719.17 | 28.45 | 720.00 | 28.44 | 719.17 | 28.44 |
| October | 723.17 | 27.87 | 744.00 | 27.85 | 723.17 | 27.86 |
| November | 567.17 | 27.00 | 718.50 | 26.94 | 567.17 | 26.96 |
| December | 378.50 | 25.74 | 713.67 | 25.76 | 360.00 | 25.80 |
| Annual Sum or Average | 6680.17 | 27.65 | 8543.00 | 27.45 | 6569.17 | 27.54 |
| Minimum of Months | 238.50 | 24.85 | 628.33 | 25.19 | 190.33 | 25.27 |
| Maximum of Months | 744.00 | 28.99 | 744.00 | 28.99 | 744.00 | 28.99 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 740.83 | 25.54 | 744.00 | 25.54 | 740.83 | 25.54 |
| February | 670.33 | 25.67 | 672.00 | 25.67 | 670.33 | 25.67 |
| March | 744.00 | 25.84 | 744.00 | 25.84 | 744.00 | 25.84 |
| April | 720.00 | 26.07 | 720.00 | 26.07 | 720.00 | 26.07 |
| May | 744.00 | 26.38 | 744.00 | 26.38 | 744.00 | 26.38 |
| June | 720.00 | 26.48 | 720.00 | 26.48 | 720.00 | 26.48 |
| July | 744.00 | 26.59 | 744.00 | 26.59 | 744.00 | 26.59 |
| August | 744.00 | 26.62 | 744.00 | 26.62 | 744.00 | 26.62 |
| September | 720.00 | 26.45 | 720.00 | 26.45 | 720.00 | 26.45 |
| October | 744.00 | 26.27 | 744.00 | 26.27 | 744.00 | 26.27 |
| November | 720.00 | 26.00 | 720.00 | 26.00 | 720.00 | 26.00 |
| December | 744.00 | 25.68 | 744.00 | 25.68 | 744.00 | 25.68 |
| Annual Sum or Average | 8755.17 | 26.13 | 8760.00 | 26.13 | 8755.17 | 26.13 |
| Minimum of Months | 670.33 | 25.54 | 672.00 | 25.54 | 670.33 | 25.54 |
| Maximum of Months | 744.00 | 26.62 | 744.00 | 26.62 | 744.00 | 26.62 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.204798E+10 | 0.517441E+09 | 712.20 | 0.183570E+10 | 0.212277E+09 | 0.00 | 0.29 | 29-JAN-17:05 | 0.00 | 01-JAN-03:40 | 2137.05 | 29-JAN-17:05 | 1839.89 | 28-JAN-14:20 | 457.38 | 30-JAN-15:40 | 533.46 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.216234E+10 | 0.548897E+09 | 641.03 | 0.187151E+10 | 0.290829E+09 | 0.00 | 0.37 | 05-FEB-15:10 | 0.00 | 01-FEB-08:35 | 2701.29 | 07-FEB-16:10 | 2434.49 | 05-FEB-15:10 | 617.77 | 07-FEB-16:20 | 714.33 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.281635E+10 | 0.731561E+09 | 716.59 | 0.250201E+10 | 0.314334E+09 | 0.00 | 0.42 | 01-MAR-15:30 | 0.00 | 04-MAR-07:40 | 2769.29 | 01-MAR-15:30 | 2769.29 | 01-MAR-15:30 | 533.45 | 28-MAR-19:00 | 825.39 | 01-MAR-15:30 | 0.00 | 01-MAR-00:10 |
| April | 0.383514E+10 | 0.101821E+10 | 717.90 | 0.325585E+10 | 0.579290E+09 | 0.00 | 0.47 | 28-APR-15:10 | 0.00 | 05-APR-05:05 | 3446.42 | 30-APR-16:15 | 2797.35 | 28-APR-15:10 | 1059.66 | 30-APR-16:15 | 947.17 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.593421E+10 | 0.165227E+10 | 744.00 | 0.493169E+10 | 0.100252E+10 | 0.00 | 0.62 | 21-MAY-13:00 | 0.12 | 03-MAY-06:00 | 4304.25 | 21-MAY-13:00 | 3848.64 | 21-MAY-13:00 | 1315.05 | 29-MAY-14:00 | 1272.41 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.726017E+10 | 0.202361E+10 | 720.00 | 0.547112E+10 | 0.178905E+10 | 0.00 | 0.62 | 09-JUN-16:30 | 0.19 | 22-JUN-08:00 | 4402.97 | 12-JUN-15:10 | 3607.51 | 09-JUN-16:40 | 1501.38 | 08-JUN-14:00 | 1318.06 | 09-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.889898E+10 | 0.252671E+10 | 744.00 | 0.653952E+10 | 0.235945E+10 | 0.00 | 0.69 | 30-JUL-16:10 | 0.22 | 03-JUL-06:00 | 5237.42 | 30-JUL-16:10 | 3801.21 | 21-JUL-17:00 | 1876.21 | 30-JUL-17:02 | 1476.78 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.964659E+10 | 0.273352E+10 | 744.00 | 0.707072E+10 | 0.257587E+10 | 0.00 | 0.75 | 10-AUG-16:10 | 0.30 | 15-AUG-07:00 | 5595.35 | 22-AUG-17:10 | 3918.91 | 10-AUG-16:10 | 2131.37 | 22-AUG-17:10 | 1629.33 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.836275E+10 | 0.228833E+10 | 720.00 | 0.620411E+10 | 0.215865E+10 | 0.00 | 0.66 | 09-SEP-16:02 | 0.23 | 26-SEP-06:00 | 5111.87 | 09-SEP-16:02 | 3829.23 | 04-SEP-16:30 | 1715.09 | 08-SEP-17:20 | 1393.94 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.707102E+10 | 0.188175E+10 | 744.00 | 0.566310E+10 | 0.140791E+10 | 0.00 | 0.59 | 07-OCT-16:10 | 0.16 | 21-OCT-07:00 | 4503.49 | 07-OCT-16:10 | 3547.26 | 09-OCT-16:04 | 1696.59 | 07-OCT-10:30 | 1226.40 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.506508E+10 | 0.130430E+10 | 720.00 | 0.426223E+10 | 0.802857E+09 | 0.00 | 0.53 | 01-NOV-15:10 | 0.04 | 22-NOV-06:40 | 3997.71 | 01-NOV-15:10 | 2956.22 | 05-NOV-15:10 | 1070.73 | 01-NOV-15:10 | 1061.74 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.310910E+10 | 0.781082E+09 | 742.06 | 0.265852E+10 | 0.450582E+09 | 0.00 | 0.36 | 05-DEC-16:10 | 0.00 | 16-DEC-06:05 | 2685.33 | 05-DEC-16:10 | 2186.72 | 03-DEC-14:30 | 678.67 | 05-DEC-16:10 | 664.79 | 05-DEC-16:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.662097E+11 | 0.180077E+11 | 8665.78 | 0.522661E+11 | 0.139436E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.204798E+10 | 0.517441E+09 | 641.03 | 0.183570E+10 | 0.212277E+09 | 0.00 | 0.29 | 0.00 | 2137.05 | 1839.89 | 457.38 | 533.46 | 0.00 | |||||||
| Maximum of Months | 0.964659E+10 | 0.273352E+10 | 744.00 | 0.707072E+10 | 0.257587E+10 | 0.00 | 0.75 | 0.30 | 5595.35 | 3918.91 | 2131.37 | 1629.33 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.131538E+10 | 0.333452E+09 | 632.72 | 0.115439E+10 | 0.160984E+09 | 0.00 | 0.23 | 29-JAN-17:10 | 0.00 | 01-JAN-01:50 | 1647.66 | 29-JAN-17:10 | 1341.83 | 29-JAN-17:10 | 423.57 | 30-JAN-16:10 | 411.29 | 29-JAN-17:10 | 0.00 | 01-JAN-00:10 |
| February | 0.157935E+10 | 0.402180E+09 | 606.44 | 0.133935E+10 | 0.239995E+09 | 0.00 | 0.31 | 07-FEB-16:20 | 0.00 | 01-FEB-04:40 | 2242.88 | 07-FEB-16:20 | 1907.52 | 06-FEB-15:10 | 577.17 | 07-FEB-16:30 | 575.92 | 07-FEB-16:20 | 0.00 | 01-FEB-00:10 |
| March | 0.239039E+10 | 0.622712E+09 | 699.38 | 0.210224E+10 | 0.288144E+09 | 0.00 | 0.38 | 27-MAR-16:01 | 0.00 | 04-MAR-07:40 | 2478.03 | 27-MAR-16:01 | 2478.03 | 27-MAR-16:01 | 521.64 | 28-MAR-19:00 | 727.53 | 27-MAR-16:01 | 0.00 | 01-MAR-00:10 |
| April | 0.361029E+10 | 0.958915E+09 | 717.82 | 0.304809E+10 | 0.562198E+09 | 0.00 | 0.46 | 28-APR-15:10 | 0.00 | 05-APR-05:05 | 3262.40 | 30-APR-16:15 | 2690.14 | 28-APR-15:10 | 1016.60 | 30-APR-16:15 | 918.22 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.594871E+10 | 0.165373E+10 | 744.00 | 0.494122E+10 | 0.100749E+10 | 0.00 | 0.63 | 31-MAY-18:00 | 0.13 | 03-MAY-06:00 | 4282.32 | 31-MAY-18:00 | 3804.85 | 21-MAY-13:00 | 1294.26 | 29-MAY-14:00 | 1294.05 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.738565E+10 | 0.205380E+10 | 720.00 | 0.558242E+10 | 0.180323E+10 | 0.00 | 0.64 | 09-JUN-16:40 | 0.20 | 07-JUN-05:00 | 4466.08 | 12-JUN-15:10 | 3697.25 | 09-JUN-16:50 | 1516.61 | 08-JUN-14:00 | 1330.98 | 09-JUN-16:40 | 0.00 | 01-JUN-00:10 |
| July | 0.894261E+10 | 0.253368E+10 | 744.00 | 0.657813E+10 | 0.236448E+10 | 0.00 | 0.69 | 30-JUL-16:10 | 0.22 | 03-JUL-06:00 | 5163.41 | 30-JUL-17:10 | 3842.99 | 21-JUL-17:00 | 1851.23 | 30-JUL-17:10 | 1448.95 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.953296E+10 | 0.269750E+10 | 744.00 | 0.696101E+10 | 0.257195E+10 | 0.00 | 0.76 | 10-AUG-16:10 | 0.30 | 15-AUG-07:00 | 5552.63 | 22-AUG-17:10 | 3859.25 | 10-AUG-16:10 | 2143.68 | 22-AUG-17:10 | 1613.62 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.795712E+10 | 0.217758E+10 | 720.00 | 0.583018E+10 | 0.212694E+10 | 0.00 | 0.64 | 09-SEP-16:02 | 0.22 | 26-SEP-06:00 | 4835.37 | 09-SEP-16:02 | 3612.42 | 04-SEP-16:40 | 1715.94 | 08-SEP-17:20 | 1321.13 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.638591E+10 | 0.170201E+10 | 744.00 | 0.502237E+10 | 0.136354E+10 | 0.00 | 0.56 | 07-OCT-16:10 | 0.15 | 21-OCT-07:00 | 4099.12 | 07-OCT-16:10 | 3086.88 | 09-OCT-16:01 | 1593.05 | 07-OCT-10:30 | 1121.03 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.426858E+10 | 0.110255E+10 | 720.00 | 0.352003E+10 | 0.748541E+09 | 0.00 | 0.47 | 01-NOV-16:01 | 0.03 | 22-NOV-07:00 | 3474.80 | 01-NOV-16:01 | 2459.45 | 01-NOV-16:03 | 1034.05 | 01-NOV-15:20 | 926.21 | 01-NOV-16:01 | 0.00 | 01-NOV-00:10 |
| December | 0.234719E+10 | 0.591543E+09 | 725.88 | 0.195994E+10 | 0.387246E+09 | 0.00 | 0.29 | 05-DEC-17:02 | 0.00 | 13-DEC-07:40 | 2150.52 | 05-DEC-17:02 | 1611.37 | 01-DEC-15:10 | 633.99 | 05-DEC-17:02 | 532.36 | 05-DEC-16:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.616641E+11 | 0.168296E+11 | 8518.25 | 0.480394E+11 | 0.136247E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.131538E+10 | 0.333452E+09 | 606.44 | 0.115439E+10 | 0.160984E+09 | 0.00 | 0.23 | 0.00 | 1647.66 | 1341.83 | 423.57 | 411.29 | 0.00 | |||||||
| Maximum of Months | 0.953296E+10 | 0.269750E+10 | 744.00 | 0.696101E+10 | 0.257195E+10 | 0.00 | 0.76 | 0.30 | 5552.63 | 3859.25 | 2143.68 | 1613.62 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.178295E+10 | 0.437613E+09 | 189.48 | 0.163666E+10 | 0.146295E+09 | 0.00 | 1.00 | 10-JAN-09:02 | 0.00 | 01-JAN-00:10 | 9730.69 | 30-JAN-08:62 | 8724.50 | 17-JAN-09:02 | 2112.08 | 30-JAN-09:02 | 2024.70 | 30-JAN-08:62 | 0.00 | 01-JAN-00:10 |
| February | 0.189113E+10 | 0.468365E+09 | 195.31 | 0.169683E+10 | 0.194308E+09 | 0.00 | 1.00 | 02-FEB-09:02 | 0.00 | 01-FEB-00:10 | 9892.54 | 09-FEB-08:62 | 8317.55 | 10-FEB-09:02 | 2484.82 | 09-FEB-08:62 | 2038.51 | 07-FEB-09:02 | 0.00 | 01-FEB-00:10 |
| March | 0.245077E+10 | 0.626026E+09 | 241.84 | 0.224448E+10 | 0.206289E+09 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:10 | 9983.61 | 29-MAR-07:02 | 9169.94 | 14-MAR-07:02 | 3052.10 | 29-MAR-07:02 | 2135.84 | 01-MAR-09:02 | 0.00 | 01-MAR-00:10 |
| April | 0.279834E+10 | 0.735823E+09 | 316.61 | 0.251030E+10 | 0.288042E+09 | 0.00 | 1.00 | 03-APR-07:02 | 0.00 | 01-APR-00:10 | 10029.45 | 12-APR-07:02 | 9240.73 | 06-APR-07:02 | 3176.04 | 12-APR-07:02 | 2187.30 | 28-APR-08:62 | 0.00 | 01-APR-00:10 |
| May | 0.463649E+10 | 0.127809E+10 | 594.06 | 0.406018E+10 | 0.576311E+09 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-02:40 | 10367.95 | 24-MAY-06:03 | 9214.90 | 05-MAY-07:02 | 4898.36 | 24-MAY-06:03 | 2353.05 | 22-MAY-08:62 | 0.00 | 01-MAY-00:10 |
| June | 0.575045E+10 | 0.157841E+10 | 683.33 | 0.453406E+10 | 0.121640E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-06:05 | 10383.45 | 08-JUN-07:02 | 9094.78 | 02-JUN-07:02 | 5494.21 | 08-JUN-07:04 | 2384.90 | 05-JUN-07:02 | 0.00 | 01-JUN-00:10 |
| July | 0.713330E+10 | 0.197573E+10 | 732.60 | 0.529700E+10 | 0.183630E+10 | 0.00 | 1.00 | 03-JUL-07:02 | 0.00 | 02-JUL-03:25 | 10308.55 | 06-JUL-06:03 | 9077.03 | 03-JUL-07:02 | 5710.38 | 27-JUL-06:03 | 2418.74 | 19-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.817887E+10 | 0.225873E+10 | 729.49 | 0.604980E+10 | 0.212907E+10 | 0.00 | 1.00 | 01-AUG-06:03 | 0.00 | 01-AUG-02:25 | 10307.64 | 31-AUG-06:03 | 7865.05 | 07-AUG-07:02 | 5670.89 | 08-AUG-06:03 | 2407.03 | 02-AUG-08:62 | 0.00 | 01-AUG-00:10 |
| September | 0.651794E+10 | 0.174781E+10 | 705.63 | 0.495359E+10 | 0.156435E+10 | 0.00 | 1.00 | 01-SEP-06:03 | 0.00 | 01-SEP-06:05 | 10375.13 | 25-SEP-06:03 | 8362.10 | 26-SEP-07:02 | 5344.94 | 28-SEP-06:03 | 2290.12 | 12-SEP-08:15 | 0.00 | 01-SEP-00:10 |
| October | 0.546904E+10 | 0.142141E+10 | 684.06 | 0.448539E+10 | 0.983646E+09 | 0.00 | 1.00 | 02-OCT-06:03 | 0.00 | 01-OCT-04:00 | 10381.48 | 17-OCT-06:03 | 9337.39 | 20-OCT-07:02 | 4809.55 | 18-OCT-06:03 | 2282.75 | 06-OCT-08:62 | 0.00 | 01-OCT-00:10 |
| November | 0.374823E+10 | 0.941509E+09 | 421.49 | 0.322727E+10 | 0.520961E+09 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-01:20 | 10175.28 | 03-NOV-07:02 | 8979.00 | 22-NOV-08:62 | 3907.83 | 03-NOV-07:03 | 2130.68 | 09-NOV-09:02 | 0.00 | 01-NOV-00:10 |
| December | 0.232597E+10 | 0.567213E+09 | 230.17 | 0.206495E+10 | 0.261026E+09 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 9912.41 | 06-DEC-08:62 | 9185.08 | 01-DEC-08:62 | 2777.15 | 15-DEC-09:02 | 2025.12 | 12-DEC-09:02 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.526835E+11 | 0.140367E+11 | 5724.07 | 0.427605E+11 | 0.992300E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.178295E+10 | 0.437613E+09 | 189.48 | 0.163666E+10 | 0.146295E+09 | 0.00 | 1.00 | 0.00 | 9730.69 | 7865.05 | 2112.08 | 2024.70 | 0.00 | |||||||
| Maximum of Months | 0.817887E+10 | 0.225873E+10 | 732.60 | 0.604980E+10 | 0.212907E+10 | 0.00 | 1.00 | 0.00 | 10383.45 | 9337.39 | 5710.38 | 2418.74 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.132826E+10 | 0.336619E+09 | 639.92 | 0.116733E+10 | 0.160933E+09 | 0.00 | 0.23 | 29-JAN-12:00 | 0.00 | 01-JAN-01:20 | 1572.03 | 29-JAN-12:00 | 1333.33 | 29-JAN-12:00 | 423.53 | 30-JAN-15:40 | 408.52 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.157558E+10 | 0.401105E+09 | 610.60 | 0.133744E+10 | 0.238140E+09 | 0.00 | 0.29 | 07-FEB-16:20 | 0.00 | 01-FEB-04:40 | 2066.73 | 07-FEB-16:20 | 1799.51 | 06-FEB-15:10 | 547.60 | 07-FEB-16:30 | 533.36 | 07-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.236105E+10 | 0.615089E+09 | 697.50 | 0.207675E+10 | 0.284300E+09 | 0.00 | 0.40 | 27-MAR-11:00 | 0.00 | 04-MAR-05:00 | 2416.24 | 27-MAR-11:00 | 2416.24 | 27-MAR-11:00 | 519.00 | 28-MAR-19:00 | 746.66 | 27-MAR-11:00 | 0.00 | 01-MAR-00:10 |
| April | 0.363786E+10 | 0.965723E+09 | 717.66 | 0.307676E+10 | 0.561094E+09 | 0.00 | 0.47 | 28-APR-12:20 | 0.00 | 01-APR-06:00 | 3143.25 | 28-APR-15:10 | 2781.04 | 28-APR-12:50 | 985.28 | 30-APR-16:15 | 895.20 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.598919E+10 | 0.166273E+10 | 744.00 | 0.498378E+10 | 0.100541E+10 | 0.00 | 0.65 | 21-MAY-13:00 | 0.13 | 03-MAY-05:40 | 4341.40 | 21-MAY-13:00 | 3906.57 | 21-MAY-13:00 | 1278.72 | 29-MAY-13:50 | 1270.39 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.739056E+10 | 0.205168E+10 | 720.00 | 0.559008E+10 | 0.180049E+10 | 0.00 | 0.64 | 09-JUN-13:00 | 0.21 | 07-JUN-05:00 | 4372.21 | 09-JUN-11:00 | 3459.45 | 09-JUN-16:50 | 1482.56 | 08-JUN-13:50 | 1301.85 | 09-JUN-13:00 | 0.00 | 01-JUN-00:10 |
| July | 0.895241E+10 | 0.253136E+10 | 744.00 | 0.659101E+10 | 0.236140E+10 | 0.00 | 0.70 | 30-JUL-16:10 | 0.23 | 03-JUL-06:00 | 5065.51 | 30-JUL-17:10 | 3679.80 | 21-JUL-17:00 | 1839.73 | 30-JUL-17:10 | 1426.19 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.954699E+10 | 0.269561E+10 | 744.00 | 0.697747E+10 | 0.256951E+10 | 0.00 | 0.75 | 10-AUG-16:10 | 0.32 | 15-AUG-06:40 | 5360.25 | 22-AUG-17:10 | 3868.86 | 16-AUG-12:00 | 2117.71 | 22-AUG-17:10 | 1551.10 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.796410E+10 | 0.217559E+10 | 720.00 | 0.584059E+10 | 0.212351E+10 | 0.00 | 0.63 | 09-SEP-16:02 | 0.23 | 26-SEP-06:00 | 4610.74 | 09-SEP-16:02 | 3416.31 | 04-SEP-17:00 | 1692.82 | 08-SEP-17:20 | 1260.48 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.640672E+10 | 0.170452E+10 | 744.00 | 0.504215E+10 | 0.136458E+10 | 0.00 | 0.55 | 07-OCT-16:10 | 0.16 | 21-OCT-06:00 | 3965.25 | 07-OCT-10:40 | 2918.08 | 09-OCT-16:01 | 1632.54 | 07-OCT-10:30 | 1073.39 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.427344E+10 | 0.110238E+10 | 720.00 | 0.352516E+10 | 0.748284E+09 | 0.00 | 0.46 | 01-NOV-14:10 | 0.03 | 22-NOV-06:40 | 3310.14 | 01-NOV-15:10 | 2325.27 | 01-NOV-14:10 | 1002.56 | 01-NOV-15:20 | 890.24 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.233481E+10 | 0.588132E+09 | 728.26 | 0.195025E+10 | 0.384557E+09 | 0.00 | 0.28 | 05-DEC-17:02 | 0.00 | 13-DEC-07:40 | 1992.68 | 05-DEC-17:02 | 1630.92 | 10-DEC-13:00 | 608.68 | 05-DEC-17:02 | 491.57 | 05-DEC-16:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.617610E+11 | 0.168305E+11 | 8529.94 | 0.481588E+11 | 0.136022E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.132826E+10 | 0.336619E+09 | 610.60 | 0.116733E+10 | 0.160933E+09 | 0.00 | 0.23 | 0.00 | 1572.03 | 1333.33 | 423.53 | 408.52 | 0.00 | |||||||
| Maximum of Months | 0.954699E+10 | 0.269561E+10 | 744.00 | 0.697747E+10 | 0.256951E+10 | 0.00 | 0.75 | 0.32 | 5360.25 | 3906.57 | 2117.71 | 1551.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.129760E+10 | 0.328759E+09 | 700.99 | 0.114150E+10 | 0.156105E+09 | 0.00 | 0.22 | 29-JAN-17:10 | 0.00 | 01-JAN-03:10 | 1328.66 | 29-JAN-17:10 | 1076.69 | 23-JAN-14:00 | 380.24 | 30-JAN-16:10 | 331.57 | 29-JAN-17:10 | 0.00 | 01-JAN-00:10 |
| February | 0.151391E+10 | 0.384600E+09 | 649.30 | 0.128314E+10 | 0.230771E+09 | 0.00 | 0.29 | 07-FEB-17:02 | 0.00 | 01-FEB-08:35 | 1780.08 | 07-FEB-17:02 | 1489.73 | 06-FEB-15:10 | 449.71 | 07-FEB-16:30 | 457.90 | 07-FEB-17:02 | 0.00 | 01-FEB-00:10 |
| March | 0.218213E+10 | 0.566511E+09 | 722.76 | 0.191526E+10 | 0.266870E+09 | 0.00 | 0.35 | 27-MAR-11:00 | 0.00 | 04-MAR-07:40 | 1883.91 | 27-MAR-16:04 | 1883.91 | 27-MAR-16:04 | 461.58 | 28-MAR-19:00 | 568.79 | 27-MAR-11:00 | 0.00 | 01-MAR-00:10 |
| April | 0.318011E+10 | 0.841404E+09 | 719.75 | 0.267487E+10 | 0.505233E+09 | 0.00 | 0.42 | 28-APR-12:00 | 0.00 | 05-APR-05:05 | 2563.27 | 30-APR-16:15 | 2107.29 | 28-APR-12:50 | 802.51 | 30-APR-16:15 | 696.72 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.504237E+10 | 0.139832E+10 | 744.00 | 0.415457E+10 | 0.887805E+09 | 0.00 | 0.58 | 31-MAY-18:00 | 0.15 | 03-MAY-06:00 | 3327.22 | 31-MAY-18:00 | 2834.73 | 21-MAY-13:00 | 997.89 | 29-MAY-14:00 | 1012.34 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.618672E+10 | 0.171774E+10 | 720.00 | 0.462158E+10 | 0.156514E+10 | 0.00 | 0.58 | 09-JUN-16:50 | 0.22 | 02-JUN-05:00 | 3406.34 | 12-JUN-15:10 | 2781.10 | 09-JUN-17:03 | 1198.21 | 08-JUN-14:00 | 1030.14 | 09-JUN-14:20 | 0.00 | 01-JUN-00:10 |
| July | 0.745332E+10 | 0.210981E+10 | 744.00 | 0.539766E+10 | 0.205566E+10 | 0.00 | 0.64 | 30-JUL-17:10 | 0.23 | 03-JUL-06:00 | 4060.17 | 30-JUL-17:10 | 2943.79 | 21-JUL-17:04 | 1480.98 | 30-JUL-17:10 | 1127.09 | 30-JUL-17:10 | 0.00 | 01-JUL-00:10 |
| August | 0.786578E+10 | 0.222570E+10 | 744.00 | 0.564128E+10 | 0.222450E+10 | 0.00 | 0.69 | 10-AUG-16:10 | 0.31 | 15-AUG-07:00 | 4281.36 | 22-AUG-17:10 | 2933.24 | 16-AUG-12:00 | 1692.78 | 22-AUG-17:10 | 1247.42 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.660422E+10 | 0.180515E+10 | 720.00 | 0.475609E+10 | 0.184813E+10 | 0.00 | 0.59 | 09-SEP-16:02 | 0.23 | 26-SEP-06:00 | 3735.91 | 09-SEP-16:02 | 2733.42 | 04-SEP-17:00 | 1414.38 | 08-SEP-17:20 | 1027.43 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.535215E+10 | 0.142325E+10 | 744.00 | 0.415106E+10 | 0.120109E+10 | 0.00 | 0.52 | 07-OCT-16:10 | 0.16 | 21-OCT-07:00 | 3222.26 | 07-OCT-16:10 | 2335.79 | 09-OCT-16:01 | 1352.23 | 07-OCT-10:30 | 884.75 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.364728E+10 | 0.939886E+09 | 720.00 | 0.298544E+10 | 0.661844E+09 | 0.00 | 0.44 | 01-NOV-16:01 | 0.04 | 22-NOV-07:00 | 2729.48 | 01-NOV-16:01 | 1895.22 | 01-NOV-16:03 | 834.39 | 01-NOV-16:01 | 729.93 | 01-NOV-16:01 | 0.00 | 01-NOV-00:10 |
| December | 0.214453E+10 | 0.539528E+09 | 736.19 | 0.178740E+10 | 0.357131E+09 | 0.00 | 0.28 | 05-DEC-17:02 | 0.00 | 16-DEC-06:05 | 1747.20 | 05-DEC-17:02 | 1347.97 | 10-DEC-13:00 | 536.40 | 05-DEC-17:02 | 430.11 | 05-DEC-17:02 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.524701E+11 | 0.142807E+11 | 8664.99 | 0.405099E+11 | 0.119603E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.129760E+10 | 0.328759E+09 | 649.30 | 0.114150E+10 | 0.156105E+09 | 0.00 | 0.22 | 0.00 | 1328.66 | 1076.69 | 380.24 | 331.57 | 0.00 | |||||||
| Maximum of Months | 0.786578E+10 | 0.222570E+10 | 744.00 | 0.564128E+10 | 0.222450E+10 | 0.00 | 0.69 | 0.31 | 4281.36 | 2943.79 | 1692.78 | 1247.42 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.129875E+10 | 0.329045E+09 | 700.76 | 0.114253E+10 | 0.156216E+09 | 0.00 | 0.22 | 29-JAN-17:10 | 0.00 | 01-JAN-03:00 | 1327.33 | 29-JAN-17:10 | 1077.01 | 23-JAN-14:00 | 380.36 | 30-JAN-16:10 | 331.24 | 29-JAN-17:10 | 0.00 | 01-JAN-00:10 |
| February | 0.151434E+10 | 0.384707E+09 | 649.43 | 0.128352E+10 | 0.230816E+09 | 0.00 | 0.29 | 07-FEB-17:02 | 0.00 | 01-FEB-08:35 | 1777.00 | 07-FEB-17:02 | 1489.05 | 06-FEB-15:10 | 449.17 | 07-FEB-16:30 | 457.11 | 07-FEB-17:02 | 0.00 | 01-FEB-00:10 |
| March | 0.218108E+10 | 0.566248E+09 | 722.73 | 0.191429E+10 | 0.266793E+09 | 0.00 | 0.35 | 27-MAR-11:00 | 0.00 | 04-MAR-07:40 | 1882.07 | 27-MAR-16:04 | 1882.07 | 27-MAR-16:04 | 461.54 | 28-MAR-19:00 | 570.14 | 27-MAR-11:00 | 0.00 | 01-MAR-00:10 |
| April | 0.318155E+10 | 0.841780E+09 | 719.75 | 0.267621E+10 | 0.505343E+09 | 0.00 | 0.42 | 28-APR-12:00 | 0.00 | 05-APR-05:05 | 2562.31 | 30-APR-16:15 | 2111.72 | 28-APR-12:50 | 802.18 | 30-APR-16:15 | 696.94 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.504441E+10 | 0.139885E+10 | 744.00 | 0.415649E+10 | 0.887924E+09 | 0.00 | 0.58 | 31-MAY-18:00 | 0.15 | 03-MAY-06:00 | 3323.56 | 31-MAY-18:00 | 2838.61 | 21-MAY-13:00 | 998.08 | 29-MAY-14:00 | 1011.25 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.618719E+10 | 0.171782E+10 | 720.00 | 0.462200E+10 | 0.156520E+10 | 0.00 | 0.58 | 09-JUN-16:50 | 0.22 | 02-JUN-05:00 | 3405.67 | 12-JUN-15:10 | 2777.15 | 09-JUN-17:03 | 1197.92 | 08-JUN-14:00 | 1030.21 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.745397E+10 | 0.210990E+10 | 744.00 | 0.539823E+10 | 0.205574E+10 | 0.00 | 0.64 | 30-JUL-17:10 | 0.23 | 03-JUL-06:00 | 4059.12 | 30-JUL-17:10 | 2940.90 | 21-JUL-17:04 | 1480.83 | 30-JUL-17:10 | 1126.94 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.786662E+10 | 0.222583E+10 | 744.00 | 0.564202E+10 | 0.222460E+10 | 0.00 | 0.69 | 10-AUG-16:10 | 0.31 | 15-AUG-07:00 | 4278.07 | 22-AUG-17:10 | 2937.66 | 16-AUG-12:00 | 1692.20 | 22-AUG-17:10 | 1246.58 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.660481E+10 | 0.180525E+10 | 720.00 | 0.475662E+10 | 0.184819E+10 | 0.00 | 0.59 | 09-SEP-16:02 | 0.23 | 26-SEP-06:00 | 3732.55 | 09-SEP-16:02 | 2730.59 | 04-SEP-17:00 | 1413.76 | 08-SEP-17:20 | 1026.51 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.535328E+10 | 0.142350E+10 | 744.00 | 0.415203E+10 | 0.120125E+10 | 0.00 | 0.52 | 07-OCT-16:10 | 0.16 | 21-OCT-07:00 | 3219.71 | 07-OCT-16:10 | 2333.71 | 09-OCT-16:01 | 1353.30 | 07-OCT-10:30 | 884.04 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.364781E+10 | 0.940001E+09 | 720.00 | 0.298585E+10 | 0.661955E+09 | 0.00 | 0.44 | 01-NOV-16:01 | 0.04 | 22-NOV-07:00 | 2727.06 | 01-NOV-16:01 | 1893.32 | 01-NOV-16:03 | 833.87 | 01-NOV-16:01 | 729.28 | 01-NOV-16:01 | 0.00 | 01-NOV-00:10 |
| December | 0.214438E+10 | 0.539486E+09 | 736.17 | 0.178725E+10 | 0.357133E+09 | 0.00 | 0.28 | 05-DEC-17:02 | 0.00 | 16-DEC-06:05 | 1744.15 | 05-DEC-17:02 | 1349.31 | 10-DEC-13:00 | 535.79 | 05-DEC-17:02 | 429.36 | 05-DEC-17:02 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.524782E+11 | 0.142824E+11 | 8664.84 | 0.405170E+11 | 0.119612E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.129875E+10 | 0.329045E+09 | 649.43 | 0.114253E+10 | 0.156216E+09 | 0.00 | 0.22 | 0.00 | 1327.33 | 1077.01 | 380.36 | 331.24 | 0.00 | |||||||
| Maximum of Months | 0.786662E+10 | 0.222583E+10 | 744.00 | 0.564202E+10 | 0.222460E+10 | 0.00 | 0.69 | 0.31 | 4278.07 | 2940.90 | 1692.20 | 1246.58 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.207188E+10 | 0.522800E+09 | 742.50 | 0.186265E+10 | 0.209232E+09 | 0.00 | 0.29 | 29-JAN-17:05 | 0.00 | 01-JAN-09:20 | 1822.53 | 29-JAN-17:05 | 1655.39 | 28-JAN-14:00 | 409.90 | 30-JAN-15:40 | 458.38 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.212861E+10 | 0.538991E+09 | 667.39 | 0.184462E+10 | 0.283992E+09 | 0.00 | 0.36 | 05-FEB-14:00 | 0.00 | 02-FEB-08:12 | 2206.44 | 07-FEB-16:10 | 2044.40 | 05-FEB-14:40 | 492.98 | 07-FEB-16:30 | 601.25 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.263500E+10 | 0.682095E+09 | 735.52 | 0.233867E+10 | 0.296330E+09 | 0.00 | 0.39 | 27-MAR-12:00 | 0.00 | 04-MAR-07:40 | 2172.94 | 01-MAR-15:10 | 2172.94 | 01-MAR-15:10 | 474.58 | 28-MAR-19:00 | 650.70 | 27-MAR-12:00 | 0.00 | 01-MAR-00:10 |
| April | 0.342578E+10 | 0.906156E+09 | 720.00 | 0.289966E+10 | 0.526117E+09 | 0.00 | 0.43 | 28-APR-12:00 | 0.01 | 05-APR-06:00 | 2754.82 | 30-APR-16:15 | 2253.49 | 28-APR-12:40 | 848.05 | 30-APR-16:15 | 730.11 | 30-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.504721E+10 | 0.140226E+10 | 744.00 | 0.416045E+10 | 0.886764E+09 | 0.00 | 0.55 | 31-MAY-18:00 | 0.14 | 03-MAY-06:00 | 3244.54 | 31-MAY-18:00 | 2885.47 | 21-MAY-13:00 | 1021.73 | 29-MAY-14:00 | 991.89 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.607792E+10 | 0.169214E+10 | 720.00 | 0.452336E+10 | 0.155457E+10 | 0.00 | 0.55 | 09-JUN-14:20 | 0.20 | 22-JUN-08:00 | 3404.82 | 04-JUN-17:10 | 2693.19 | 09-JUN-17:03 | 1184.87 | 08-JUN-14:00 | 1022.21 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.742867E+10 | 0.210827E+10 | 744.00 | 0.537376E+10 | 0.205491E+10 | 0.00 | 0.63 | 30-JUL-17:10 | 0.22 | 03-JUL-06:00 | 4141.32 | 30-JUL-17:10 | 2911.44 | 21-JUL-17:06 | 1508.81 | 30-JUL-17:10 | 1151.24 | 30-JUL-17:10 | 0.00 | 01-JUL-00:10 |
| August | 0.800130E+10 | 0.226813E+10 | 744.00 | 0.576701E+10 | 0.223428E+10 | 0.00 | 0.67 | 10-AUG-16:10 | 0.31 | 15-AUG-07:10 | 4327.78 | 22-AUG-17:10 | 3064.14 | 16-AUG-12:00 | 1679.85 | 22-AUG-17:10 | 1264.59 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.703752E+10 | 0.192394E+10 | 720.00 | 0.514949E+10 | 0.188803E+10 | 0.00 | 0.61 | 09-SEP-16:02 | 0.24 | 26-SEP-06:00 | 4015.85 | 09-SEP-16:02 | 2946.87 | 04-SEP-16:40 | 1418.52 | 10-SEP-17:10 | 1102.24 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.607127E+10 | 0.161227E+10 | 744.00 | 0.481675E+10 | 0.125452E+10 | 0.00 | 0.56 | 07-OCT-16:10 | 0.18 | 21-OCT-06:00 | 3630.52 | 07-OCT-16:10 | 2798.52 | 09-OCT-16:03 | 1462.96 | 07-OCT-10:30 | 997.94 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.447954E+10 | 0.115063E+10 | 720.00 | 0.375570E+10 | 0.723838E+09 | 0.00 | 0.50 | 01-NOV-14:10 | 0.06 | 22-NOV-06:40 | 3235.43 | 01-NOV-14:10 | 2421.30 | 05-NOV-13:30 | 872.15 | 01-NOV-15:10 | 873.94 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.294022E+10 | 0.737028E+09 | 743.67 | 0.251480E+10 | 0.425418E+09 | 0.00 | 0.35 | 04-DEC-13:00 | 0.00 | 16-DEC-06:05 | 2243.97 | 05-DEC-16:10 | 1951.37 | 03-DEC-13:00 | 615.86 | 25-DEC-11:30 | 568.05 | 04-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.573449E+11 | 0.155447E+11 | 8745.08 | 0.450069E+11 | 0.123380E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.207188E+10 | 0.522800E+09 | 667.39 | 0.184462E+10 | 0.209232E+09 | 0.00 | 0.29 | 0.00 | 1822.53 | 1655.39 | 409.90 | 458.38 | 0.00 | |||||||
| Maximum of Months | 0.800130E+10 | 0.226813E+10 | 744.00 | 0.576701E+10 | 0.223428E+10 | 0.00 | 0.67 | 0.31 | 4327.78 | 3064.14 | 1679.85 | 1264.59 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.228426E+10 | 0.575797E+09 | 743.50 | 0.206132E+10 | 0.222936E+09 | 0.00 | 0.31 | 29-JAN-17:05 | 0.00 | 01-JAN-09:20 | 1957.75 | 29-JAN-17:05 | 1748.36 | 28-JAN-14:00 | 432.51 | 30-JAN-15:40 | 489.09 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.233342E+10 | 0.589976E+09 | 670.62 | 0.203034E+10 | 0.303080E+09 | 0.00 | 0.38 | 05-FEB-14:00 | 0.00 | 13-FEB-08:50 | 2305.15 | 05-FEB-14:00 | 2179.55 | 05-FEB-14:40 | 503.08 | 07-FEB-16:30 | 637.47 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.287665E+10 | 0.743011E+09 | 739.85 | 0.256238E+10 | 0.314271E+09 | 0.00 | 0.41 | 27-MAR-12:00 | 0.00 | 06-MAR-06:03 | 2266.71 | 27-MAR-13:00 | 2266.71 | 27-MAR-13:00 | 492.53 | 28-MAR-19:00 | 683.39 | 27-MAR-12:00 | 0.00 | 01-MAR-00:10 |
| April | 0.373262E+10 | 0.984406E+09 | 720.00 | 0.317937E+10 | 0.553247E+09 | 0.00 | 0.45 | 30-APR-16:15 | 0.03 | 05-APR-06:00 | 2944.68 | 30-APR-16:15 | 2348.93 | 28-APR-12:40 | 874.06 | 30-APR-16:15 | 778.49 | 30-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.542724E+10 | 0.150298E+10 | 744.00 | 0.451147E+10 | 0.915777E+09 | 0.00 | 0.57 | 21-MAY-13:00 | 0.16 | 03-MAY-06:00 | 3381.60 | 21-MAY-13:00 | 3057.47 | 21-MAY-13:00 | 1055.81 | 29-MAY-14:00 | 1026.28 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.645837E+10 | 0.179330E+10 | 720.00 | 0.486557E+10 | 0.159280E+10 | 0.00 | 0.56 | 09-JUN-14:20 | 0.22 | 22-JUN-08:00 | 3595.41 | 04-JUN-17:10 | 2787.56 | 09-JUN-17:03 | 1195.80 | 08-JUN-14:00 | 1050.88 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.784494E+10 | 0.222085E+10 | 744.00 | 0.575108E+10 | 0.209386E+10 | 0.00 | 0.66 | 30-JUL-17:10 | 0.25 | 03-JUL-06:00 | 4349.03 | 30-JUL-17:10 | 3034.11 | 30-JUL-14:00 | 1536.76 | 30-JUL-17:10 | 1205.39 | 30-JUL-17:10 | 0.00 | 01-JUL-00:10 |
| August | 0.840928E+10 | 0.237790E+10 | 744.00 | 0.613773E+10 | 0.227155E+10 | 0.00 | 0.69 | 10-AUG-16:10 | 0.33 | 15-AUG-07:10 | 4453.45 | 22-AUG-17:10 | 3172.66 | 16-AUG-12:00 | 1698.34 | 22-AUG-17:10 | 1292.52 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.743996E+10 | 0.202879E+10 | 720.00 | 0.551363E+10 | 0.192633E+10 | 0.00 | 0.63 | 09-SEP-16:02 | 0.26 | 26-SEP-06:00 | 4192.43 | 09-SEP-16:02 | 3142.30 | 04-SEP-16:40 | 1442.98 | 10-SEP-17:10 | 1148.07 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.647997E+10 | 0.171596E+10 | 744.00 | 0.519297E+10 | 0.128700E+10 | 0.00 | 0.58 | 07-OCT-16:10 | 0.19 | 21-OCT-06:00 | 3806.88 | 07-OCT-16:10 | 2996.30 | 09-OCT-15:10 | 1482.33 | 07-OCT-10:30 | 1043.75 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.484073E+10 | 0.124004E+10 | 720.00 | 0.409047E+10 | 0.750255E+09 | 0.00 | 0.52 | 01-NOV-14:10 | 0.08 | 22-NOV-06:40 | 3340.83 | 01-NOV-14:10 | 2603.01 | 05-NOV-13:30 | 881.27 | 01-NOV-15:10 | 901.33 | 01-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.321675E+10 | 0.805140E+09 | 744.00 | 0.276736E+10 | 0.449384E+09 | 0.00 | 0.37 | 03-DEC-14:50 | 0.01 | 16-DEC-06:05 | 2341.58 | 05-DEC-16:10 | 2103.71 | 03-DEC-13:00 | 637.53 | 25-DEC-11:30 | 600.59 | 03-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.613442E+11 | 0.165781E+11 | 8753.98 | 0.486637E+11 | 0.126805E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.228426E+10 | 0.575797E+09 | 670.62 | 0.203034E+10 | 0.222936E+09 | 0.00 | 0.31 | 0.00 | 1957.75 | 1748.36 | 432.51 | 489.09 | 0.00 | |||||||
| Maximum of Months | 0.840928E+10 | 0.237790E+10 | 744.00 | 0.613773E+10 | 0.227155E+10 | 0.00 | 0.69 | 0.33 | 4453.45 | 3172.66 | 1698.34 | 1292.52 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.372756E+10 | 0.941525E+09 | 627.99 | 0.332359E+10 | 0.403973E+09 | 0.00 | 0.29 | 29-JAN-16:10 | 0.00 | 01-JAN-02:00 | 4497.29 | 29-JAN-17:05 | 3999.85 | 28-JAN-14:30 | 934.49 | 30-JAN-15:40 | 1133.31 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.443045E+10 | 0.112460E+10 | 616.71 | 0.382960E+10 | 0.600853E+09 | 0.00 | 0.39 | 05-FEB-15:10 | 0.00 | 01-FEB-04:00 | 6043.36 | 07-FEB-16:10 | 5540.44 | 05-FEB-15:10 | 1453.40 | 07-FEB-16:20 | 1619.23 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.640263E+10 | 0.166000E+10 | 721.31 | 0.570112E+10 | 0.701505E+09 | 0.00 | 0.46 | 01-MAR-15:30 | 0.00 | 04-MAR-07:40 | 6489.67 | 01-MAR-15:30 | 6489.67 | 01-MAR-15:30 | 1207.78 | 31-MAR-18:00 | 1922.49 | 01-MAR-15:30 | 0.00 | 01-MAR-00:10 |
| April | 0.875387E+10 | 0.231849E+10 | 717.86 | 0.744318E+10 | 0.131070E+10 | 0.00 | 0.51 | 28-APR-15:10 | 0.00 | 05-APR-05:05 | 7956.78 | 30-APR-16:15 | 6534.99 | 28-APR-15:10 | 2532.79 | 30-APR-15:40 | 2221.46 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.128293E+11 | 0.357081E+10 | 744.00 | 0.106339E+11 | 0.219539E+10 | 0.00 | 0.69 | 21-MAY-13:00 | 0.12 | 03-MAY-06:00 | 10488.84 | 21-MAY-13:00 | 9290.90 | 21-MAY-13:00 | 3173.06 | 29-MAY-13:50 | 3046.03 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.153668E+11 | 0.428297E+10 | 720.00 | 0.114395E+11 | 0.392736E+10 | 0.00 | 0.65 | 09-JUN-16:10 | 0.17 | 22-JUN-08:00 | 9964.65 | 12-JUN-15:10 | 8075.14 | 09-JUN-16:03 | 3558.57 | 08-JUN-14:00 | 2961.44 | 09-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.183171E+11 | 0.520629E+10 | 744.00 | 0.131819E+11 | 0.513520E+10 | 0.00 | 0.71 | 30-JUL-16:10 | 0.19 | 03-JUL-06:00 | 11643.18 | 30-JUL-16:10 | 8113.01 | 21-JUL-16:30 | 4361.77 | 30-JUL-17:02 | 3261.18 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.191631E+11 | 0.544671E+10 | 744.00 | 0.136102E+11 | 0.555288E+10 | 0.00 | 0.75 | 10-AUG-16:10 | 0.24 | 15-AUG-07:10 | 12117.29 | 22-AUG-17:10 | 8162.37 | 10-AUG-16:10 | 5002.63 | 22-AUG-17:10 | 3493.81 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.162230E+11 | 0.445740E+10 | 720.00 | 0.116512E+11 | 0.457185E+10 | 0.00 | 0.66 | 09-SEP-16:02 | 0.18 | 26-SEP-06:00 | 10855.26 | 09-SEP-16:02 | 7798.50 | 04-SEP-16:13 | 3890.30 | 09-SEP-16:02 | 2952.87 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.131090E+11 | 0.351037E+10 | 744.00 | 0.102335E+11 | 0.287553E+10 | 0.00 | 0.57 | 07-OCT-16:10 | 0.10 | 21-OCT-07:00 | 9248.37 | 07-OCT-16:10 | 7275.09 | 19-OCT-15:10 | 3753.94 | 07-OCT-10:30 | 2519.99 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.899681E+10 | 0.233143E+10 | 718.50 | 0.742623E+10 | 0.157058E+10 | 0.00 | 0.51 | 01-NOV-15:10 | 0.00 | 22-NOV-06:05 | 8302.76 | 01-NOV-15:10 | 5970.27 | 05-NOV-15:10 | 2422.76 | 01-NOV-15:10 | 2203.56 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.537068E+10 | 0.135173E+10 | 699.26 | 0.454023E+10 | 0.830448E+09 | 0.00 | 0.34 | 05-DEC-15:30 | 0.00 | 01-DEC-06:05 | 5524.64 | 05-DEC-15:30 | 4494.96 | 03-DEC-14:30 | 1491.64 | 05-DEC-15:30 | 1363.94 | 05-DEC-15:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.132690E+12 | 0.362023E+11 | 8517.64 | 0.103014E+12 | 0.296762E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.372756E+10 | 0.941525E+09 | 616.71 | 0.332359E+10 | 0.403973E+09 | 0.00 | 0.29 | 0.00 | 4497.29 | 3999.85 | 934.49 | 1133.31 | 0.00 | |||||||
| Maximum of Months | 0.191631E+11 | 0.544671E+10 | 744.00 | 0.136102E+11 | 0.555288E+10 | 0.00 | 0.75 | 0.24 | 12117.29 | 9290.90 | 5002.63 | 3493.81 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.220778E+10 | 0.559748E+09 | 530.85 | 0.191902E+10 | 0.288759E+09 | 0.00 | 0.22 | 29-JAN-17:10 | 0.00 | 01-JAN-00:10 | 3390.74 | 29-JAN-17:10 | 2742.68 | 29-JAN-17:10 | 862.91 | 30-JAN-16:10 | 849.24 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.319555E+10 | 0.813952E+09 | 565.90 | 0.270231E+10 | 0.493232E+09 | 0.00 | 0.32 | 07-FEB-16:20 | 0.00 | 01-FEB-03:10 | 4987.93 | 07-FEB-16:20 | 4239.79 | 06-FEB-15:10 | 1345.46 | 07-FEB-16:20 | 1275.41 | 07-FEB-16:20 | 0.00 | 01-FEB-00:10 |
| March | 0.548754E+10 | 0.142693E+10 | 706.85 | 0.484175E+10 | 0.645790E+09 | 0.00 | 0.41 | 27-MAR-16:04 | 0.00 | 04-MAR-07:40 | 5734.85 | 27-MAR-16:04 | 5734.85 | 27-MAR-16:04 | 1168.01 | 28-MAR-19:00 | 1676.74 | 01-MAR-15:30 | 0.00 | 01-MAR-00:10 |
| April | 0.825764E+10 | 0.218769E+10 | 717.90 | 0.698616E+10 | 0.127147E+10 | 0.00 | 0.51 | 28-APR-15:10 | 0.00 | 05-APR-05:05 | 7617.68 | 28-APR-15:10 | 6288.44 | 28-APR-15:10 | 2425.91 | 30-APR-15:40 | 2152.43 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.128271E+11 | 0.356466E+10 | 744.00 | 0.106287E+11 | 0.219848E+10 | 0.00 | 0.70 | 21-MAY-13:00 | 0.12 | 03-MAY-05:40 | 10321.58 | 21-MAY-13:00 | 9169.28 | 21-MAY-13:00 | 3119.46 | 29-MAY-13:50 | 2994.58 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.155894E+11 | 0.433520E+10 | 720.00 | 0.116403E+11 | 0.394910E+10 | 0.00 | 0.68 | 09-JUN-16:12 | 0.18 | 07-JUN-05:00 | 10092.18 | 12-JUN-15:10 | 8248.10 | 09-JUN-16:30 | 3584.02 | 08-JUN-14:00 | 2981.26 | 09-JUN-16:12 | 0.00 | 01-JUN-00:10 |
| July | 0.183641E+11 | 0.520907E+10 | 744.00 | 0.132271E+11 | 0.513705E+10 | 0.00 | 0.71 | 30-JUL-16:10 | 0.19 | 03-JUL-06:00 | 11368.73 | 30-JUL-16:10 | 8177.67 | 21-JUL-16:30 | 4302.65 | 30-JUL-17:02 | 3195.19 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.188815E+11 | 0.535959E+10 | 744.00 | 0.133505E+11 | 0.553098E+10 | 0.00 | 0.76 | 10-AUG-16:10 | 0.25 | 15-AUG-07:00 | 12010.67 | 22-AUG-17:10 | 8031.32 | 10-AUG-16:10 | 5015.03 | 22-AUG-17:10 | 3457.63 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.153282E+11 | 0.421160E+10 | 720.00 | 0.108459E+11 | 0.448228E+10 | 0.00 | 0.63 | 09-SEP-16:02 | 0.17 | 26-SEP-06:00 | 10201.89 | 09-SEP-16:02 | 7281.78 | 04-SEP-16:30 | 3848.28 | 08-SEP-17:20 | 2780.89 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.116238E+11 | 0.311640E+10 | 744.00 | 0.887253E+10 | 0.275122E+10 | 0.00 | 0.53 | 07-OCT-16:10 | 0.10 | 21-OCT-07:00 | 8314.68 | 07-OCT-16:10 | 6220.78 | 19-OCT-16:04 | 3484.57 | 07-OCT-10:30 | 2275.37 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.728609E+10 | 0.189368E+10 | 717.10 | 0.586428E+10 | 0.142181E+10 | 0.00 | 0.45 | 01-NOV-16:01 | 0.00 | 22-NOV-06:05 | 7018.94 | 01-NOV-15:20 | 4771.35 | 01-NOV-16:03 | 2303.21 | 01-NOV-15:20 | 1868.77 | 01-NOV-16:01 | 0.00 | 01-NOV-00:10 |
| December | 0.374597E+10 | 0.946008E+09 | 651.54 | 0.307373E+10 | 0.672231E+09 | 0.00 | 0.27 | 05-DEC-16:10 | 0.00 | 01-DEC-06:05 | 4248.52 | 05-DEC-16:10 | 3066.68 | 10-DEC-13:30 | 1355.67 | 05-DEC-16:10 | 1052.44 | 05-DEC-16:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.122795E+12 | 0.336245E+11 | 8306.14 | 0.939522E+11 | 0.288424E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.220778E+10 | 0.559748E+09 | 530.85 | 0.191902E+10 | 0.288759E+09 | 0.00 | 0.22 | 0.00 | 3390.74 | 2742.68 | 862.91 | 849.24 | 0.00 | |||||||
| Maximum of Months | 0.188815E+11 | 0.535959E+10 | 744.00 | 0.133505E+11 | 0.553098E+10 | 0.00 | 0.76 | 0.25 | 12010.67 | 9169.28 | 5015.03 | 3457.63 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.376725E+10 | 0.951081E+09 | 636.78 | 0.336050E+10 | 0.406749E+09 | 0.00 | 0.30 | 29-JAN-11:50 | 0.00 | 01-JAN-01:40 | 4440.36 | 29-JAN-11:50 | 4025.87 | 28-JAN-13:50 | 991.35 | 29-JAN-09:50 | 1139.79 | 29-JAN-11:50 | 0.00 | 01-JAN-00:10 |
| February | 0.442936E+10 | 0.112368E+10 | 619.74 | 0.382881E+10 | 0.600544E+09 | 0.00 | 0.40 | 05-FEB-14:00 | 0.00 | 01-FEB-03:50 | 5724.03 | 05-FEB-14:00 | 5394.46 | 05-FEB-14:00 | 1388.02 | 07-FEB-16:20 | 1579.43 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.634882E+10 | 0.164562E+10 | 722.79 | 0.565006E+10 | 0.698760E+09 | 0.00 | 0.46 | 27-MAR-11:30 | 0.00 | 04-MAR-07:40 | 6233.67 | 27-MAR-13:00 | 6233.67 | 27-MAR-13:00 | 1188.72 | 28-MAR-19:00 | 1872.91 | 27-MAR-11:20 | 0.00 | 01-MAR-00:10 |
| April | 0.882458E+10 | 0.233547E+10 | 717.90 | 0.751160E+10 | 0.131298E+10 | 0.00 | 0.52 | 28-APR-14:30 | 0.00 | 05-APR-05:05 | 7657.47 | 30-APR-15:40 | 6793.42 | 28-APR-13:00 | 2472.77 | 30-APR-15:40 | 2166.77 | 28-APR-14:30 | 0.00 | 01-APR-00:10 |
| May | 0.129253E+11 | 0.359242E+10 | 744.00 | 0.107285E+11 | 0.219680E+10 | 0.00 | 0.73 | 21-MAY-13:00 | 0.12 | 03-MAY-05:40 | 10739.12 | 21-MAY-13:00 | 9534.59 | 21-MAY-13:00 | 3140.74 | 29-MAY-13:50 | 3099.88 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.153897E+11 | 0.428168E+10 | 720.00 | 0.114605E+11 | 0.392918E+10 | 0.00 | 0.65 | 09-JUN-12:50 | 0.18 | 07-JUN-05:00 | 9788.18 | 09-JUN-11:00 | 7494.67 | 09-JUN-16:03 | 3475.14 | 08-JUN-13:50 | 2914.87 | 09-JUN-12:50 | 0.00 | 01-JUN-00:10 |
| July | 0.183497E+11 | 0.520485E+10 | 744.00 | 0.132136E+11 | 0.513609E+10 | 0.00 | 0.71 | 30-JUL-16:10 | 0.19 | 03-JUL-06:00 | 11323.64 | 30-JUL-16:10 | 7804.85 | 30-JUL-14:00 | 4331.14 | 30-JUL-17:02 | 3167.87 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.192051E+11 | 0.544660E+10 | 744.00 | 0.136488E+11 | 0.555635E+10 | 0.00 | 0.73 | 10-AUG-16:10 | 0.26 | 15-AUG-06:40 | 11614.11 | 22-AUG-17:10 | 8320.58 | 16-AUG-12:00 | 4928.65 | 22-AUG-17:10 | 3329.77 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.162497E+11 | 0.445646E+10 | 720.00 | 0.116781E+11 | 0.457164E+10 | 0.00 | 0.64 | 09-SEP-16:02 | 0.18 | 26-SEP-06:00 | 10259.86 | 09-SEP-16:02 | 7354.77 | 04-SEP-14:00 | 3803.86 | 08-SEP-17:20 | 2793.17 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.131666E+11 | 0.351885E+10 | 744.00 | 0.102799E+11 | 0.288671E+10 | 0.00 | 0.57 | 07-OCT-13:30 | 0.11 | 21-OCT-06:00 | 8900.59 | 07-OCT-13:10 | 6860.33 | 09-OCT-15:10 | 3847.67 | 07-OCT-10:30 | 2444.27 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.901899E+10 | 0.233364E+10 | 718.72 | 0.744120E+10 | 0.157780E+10 | 0.00 | 0.51 | 01-NOV-14:10 | 0.00 | 22-NOV-06:05 | 8001.75 | 01-NOV-14:10 | 5742.18 | 05-NOV-13:30 | 2349.88 | 01-NOV-15:10 | 2152.38 | 01-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.535311E+10 | 0.134652E+10 | 703.32 | 0.452301E+10 | 0.830105E+09 | 0.00 | 0.34 | 04-DEC-13:20 | 0.00 | 01-DEC-06:05 | 5209.51 | 05-DEC-14:00 | 4468.72 | 03-DEC-13:20 | 1416.28 | 05-DEC-15:30 | 1321.05 | 04-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.133028E+12 | 0.362369E+11 | 8535.25 | 0.103324E+12 | 0.297037E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.376725E+10 | 0.951081E+09 | 619.74 | 0.336050E+10 | 0.406749E+09 | 0.00 | 0.30 | 0.00 | 4440.36 | 4025.87 | 991.35 | 1139.79 | 0.00 | |||||||
| Maximum of Months | 0.192051E+11 | 0.544660E+10 | 744.00 | 0.136488E+11 | 0.555635E+10 | 0.00 | 0.73 | 0.26 | 11614.11 | 9534.59 | 4928.65 | 3329.77 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.223464E+10 | 0.566472E+09 | 544.03 | 0.194375E+10 | 0.290897E+09 | 0.00 | 0.22 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 | 3239.39 | 29-JAN-12:00 | 2730.97 | 29-JAN-12:00 | 862.82 | 30-JAN-16:10 | 842.06 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.319058E+10 | 0.812511E+09 | 571.49 | 0.269851E+10 | 0.492067E+09 | 0.00 | 0.30 | 07-FEB-16:20 | 0.00 | 01-FEB-03:10 | 4526.72 | 07-FEB-16:20 | 3938.67 | 06-FEB-15:10 | 1265.30 | 07-FEB-16:20 | 1167.43 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.543274E+10 | 0.141260E+10 | 708.49 | 0.479056E+10 | 0.642178E+09 | 0.00 | 0.44 | 27-MAR-11:00 | 0.00 | 04-MAR-05:00 | 5586.68 | 27-MAR-11:00 | 5586.68 | 27-MAR-11:00 | 1164.43 | 28-MAR-19:00 | 1717.15 | 27-MAR-11:00 | 0.00 | 01-MAR-00:10 |
| April | 0.832809E+10 | 0.220492E+10 | 717.90 | 0.705435E+10 | 0.127374E+10 | 0.00 | 0.51 | 28-APR-14:30 | 0.00 | 05-APR-05:05 | 7388.67 | 28-APR-15:10 | 6469.48 | 28-APR-13:00 | 2362.25 | 30-APR-15:40 | 2088.66 | 28-APR-14:30 | 0.00 | 01-APR-00:10 |
| May | 0.129229E+11 | 0.358586E+10 | 744.00 | 0.107231E+11 | 0.219977E+10 | 0.00 | 0.74 | 21-MAY-13:00 | 0.12 | 03-MAY-05:40 | 10569.76 | 21-MAY-13:00 | 9410.28 | 21-MAY-13:00 | 3088.91 | 29-MAY-13:50 | 3047.52 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.156120E+11 | 0.433313E+10 | 720.00 | 0.116612E+11 | 0.395078E+10 | 0.00 | 0.67 | 09-JUN-11:00 | 0.19 | 07-JUN-05:00 | 9942.49 | 09-JUN-11:00 | 7643.07 | 09-JUN-16:02 | 3502.05 | 08-JUN-13:50 | 2922.70 | 09-JUN-12:50 | 0.00 | 01-JUN-00:10 |
| July | 0.183964E+11 | 0.520688E+10 | 744.00 | 0.132586E+11 | 0.513783E+10 | 0.00 | 0.72 | 14-JUL-14:00 | 0.20 | 03-JUL-06:00 | 11050.70 | 30-JUL-16:10 | 7763.34 | 15-JUL-11:00 | 4271.99 | 30-JUL-17:02 | 3135.25 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.189235E+11 | 0.535925E+10 | 744.00 | 0.133890E+11 | 0.553447E+10 | 0.00 | 0.75 | 10-AUG-16:10 | 0.26 | 15-AUG-06:40 | 11508.93 | 22-AUG-17:10 | 8017.67 | 16-AUG-12:00 | 4940.70 | 22-AUG-17:10 | 3293.65 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.153550E+11 | 0.421146E+10 | 720.00 | 0.108729E+11 | 0.448215E+10 | 0.00 | 0.62 | 09-SEP-16:02 | 0.18 | 26-SEP-06:00 | 9608.15 | 09-SEP-16:02 | 6756.92 | 04-SEP-16:30 | 3783.03 | 08-SEP-17:20 | 2621.25 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.116832E+11 | 0.312667E+10 | 744.00 | 0.891895E+10 | 0.276426E+10 | 0.00 | 0.52 | 07-OCT-16:10 | 0.10 | 21-OCT-06:00 | 7923.48 | 07-OCT-10:30 | 5771.61 | 19-OCT-15:10 | 3599.65 | 07-OCT-10:30 | 2151.24 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.730923E+10 | 0.189723E+10 | 717.50 | 0.587899E+10 | 0.143024E+10 | 0.00 | 0.44 | 01-NOV-14:10 | 0.00 | 22-NOV-06:05 | 6633.72 | 01-NOV-15:10 | 4467.06 | 01-NOV-14:10 | 2214.04 | 01-NOV-15:10 | 1785.19 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.372374E+10 | 0.940106E+09 | 657.01 | 0.305341E+10 | 0.670330E+09 | 0.00 | 0.25 | 05-DEC-16:10 | 0.00 | 01-DEC-06:05 | 3811.46 | 05-DEC-16:10 | 3141.64 | 10-DEC-13:00 | 1267.48 | 05-DEC-17:02 | 944.75 | 05-DEC-16:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.123112E+12 | 0.336571E+11 | 8332.42 | 0.942434E+11 | 0.288687E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.223464E+10 | 0.566472E+09 | 544.03 | 0.194375E+10 | 0.290897E+09 | 0.00 | 0.22 | 0.00 | 3239.39 | 2730.97 | 862.82 | 842.06 | 0.00 | |||||||
| Maximum of Months | 0.189235E+11 | 0.535925E+10 | 744.00 | 0.133890E+11 | 0.553447E+10 | 0.00 | 0.75 | 0.26 | 11508.93 | 9410.28 | 4940.70 | 3293.65 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.236863E+10 | 0.600209E+09 | 655.90 | 0.206801E+10 | 0.300619E+09 | 0.00 | 0.21 | 29-JAN-17:10 | 0.00 | 01-JAN-02:30 | 2688.89 | 29-JAN-17:10 | 2203.90 | 23-JAN-14:00 | 788.34 | 30-JAN-16:10 | 671.38 | 29-JAN-17:10 | 0.00 | 01-JAN-00:10 |
| February | 0.310324E+10 | 0.788411E+09 | 638.48 | 0.262009E+10 | 0.483148E+09 | 0.00 | 0.29 | 07-FEB-17:02 | 0.00 | 01-FEB-04:50 | 3773.92 | 07-FEB-17:02 | 3183.08 | 06-FEB-15:10 | 1004.80 | 07-FEB-16:30 | 969.29 | 07-FEB-17:02 | 0.00 | 01-FEB-00:10 |
| March | 0.485841E+10 | 0.125982E+10 | 729.17 | 0.427140E+10 | 0.587010E+09 | 0.00 | 0.37 | 27-MAR-11:00 | 0.00 | 04-MAR-07:40 | 4150.55 | 27-MAR-16:04 | 4150.55 | 27-MAR-16:04 | 1004.27 | 28-MAR-19:00 | 1251.09 | 27-MAR-11:00 | 0.00 | 01-MAR-00:10 |
| April | 0.698808E+10 | 0.184634E+10 | 719.50 | 0.588089E+10 | 0.110718E+10 | 0.00 | 0.44 | 28-APR-15:10 | 0.00 | 05-APR-05:05 | 5626.28 | 30-APR-16:15 | 4666.11 | 28-APR-12:50 | 1824.28 | 30-APR-16:15 | 1564.91 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.105042E+11 | 0.291546E+10 | 744.00 | 0.862200E+10 | 0.188216E+10 | 0.00 | 0.60 | 21-MAY-13:00 | 0.14 | 03-MAY-05:40 | 7289.14 | 21-MAY-13:00 | 6541.55 | 21-MAY-13:00 | 2288.77 | 29-MAY-14:00 | 2196.53 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.126629E+11 | 0.352044E+10 | 720.00 | 0.934186E+10 | 0.332103E+10 | 0.00 | 0.59 | 09-JUN-14:20 | 0.20 | 02-JUN-05:00 | 7353.64 | 12-JUN-15:10 | 5882.89 | 09-JUN-16:30 | 2707.32 | 08-JUN-14:00 | 2222.91 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.149137E+11 | 0.423135E+10 | 744.00 | 0.105833E+11 | 0.433042E+10 | 0.00 | 0.63 | 30-JUL-17:10 | 0.20 | 03-JUL-06:00 | 8502.95 | 30-JUL-17:10 | 5964.94 | 21-JUL-17:04 | 3302.11 | 30-JUL-17:10 | 2397.24 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.152842E+11 | 0.434145E+10 | 744.00 | 0.106398E+11 | 0.464444E+10 | 0.00 | 0.67 | 10-AUG-16:10 | 0.26 | 15-AUG-07:00 | 8896.10 | 22-AUG-17:10 | 5880.00 | 16-AUG-12:00 | 3783.09 | 22-AUG-17:10 | 2578.58 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.125734E+11 | 0.345110E+10 | 720.00 | 0.877406E+10 | 0.379929E+10 | 0.00 | 0.57 | 09-SEP-16:02 | 0.19 | 26-SEP-06:00 | 7598.16 | 09-SEP-16:02 | 5279.56 | 04-SEP-16:40 | 3046.07 | 08-SEP-17:20 | 2089.04 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.977810E+10 | 0.261379E+10 | 744.00 | 0.738457E+10 | 0.239353E+10 | 0.00 | 0.48 | 07-OCT-16:10 | 0.12 | 21-OCT-07:00 | 6348.35 | 07-OCT-16:10 | 4497.01 | 09-OCT-16:09 | 2868.99 | 07-OCT-10:30 | 1746.22 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.640725E+10 | 0.165944E+10 | 718.84 | 0.513658E+10 | 0.127067E+10 | 0.00 | 0.41 | 01-NOV-16:01 | 0.00 | 22-NOV-06:05 | 5371.94 | 01-NOV-16:01 | 3593.31 | 01-NOV-16:03 | 1779.25 | 01-NOV-16:01 | 1437.76 | 01-NOV-16:01 | 0.00 | 01-NOV-00:10 |
| December | 0.369411E+10 | 0.930987E+09 | 712.67 | 0.303456E+10 | 0.659551E+09 | 0.00 | 0.26 | 05-DEC-17:04 | 0.00 | 08-DEC-06:05 | 3382.85 | 05-DEC-17:04 | 2591.87 | 10-DEC-13:00 | 1108.50 | 05-DEC-17:02 | 832.36 | 05-DEC-17:04 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.103136E+12 | 0.281588E+11 | 8590.56 | 0.783571E+11 | 0.247791E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.236863E+10 | 0.600209E+09 | 638.48 | 0.206801E+10 | 0.300619E+09 | 0.00 | 0.21 | 0.00 | 2688.89 | 2203.90 | 788.34 | 671.38 | 0.00 | |||||||
| Maximum of Months | 0.152842E+11 | 0.434145E+10 | 744.00 | 0.106398E+11 | 0.464444E+10 | 0.00 | 0.67 | 0.26 | 8896.10 | 6541.55 | 3783.09 | 2578.58 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.237267E+10 | 0.601224E+09 | 655.90 | 0.207172E+10 | 0.300949E+09 | 0.00 | 0.21 | 29-JAN-17:10 | 0.00 | 01-JAN-02:20 | 2685.65 | 29-JAN-17:10 | 2204.30 | 23-JAN-14:00 | 788.59 | 30-JAN-16:10 | 672.60 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.310459E+10 | 0.788752E+09 | 639.19 | 0.262133E+10 | 0.483265E+09 | 0.00 | 0.29 | 07-FEB-17:02 | 0.00 | 01-FEB-04:50 | 3766.33 | 07-FEB-17:02 | 3181.11 | 06-FEB-15:10 | 1003.40 | 07-FEB-16:30 | 967.36 | 07-FEB-17:02 | 0.00 | 01-FEB-00:10 |
| March | 0.485694E+10 | 0.125945E+10 | 729.01 | 0.427004E+10 | 0.586900E+09 | 0.00 | 0.37 | 27-MAR-11:00 | 0.00 | 04-MAR-07:40 | 4146.24 | 27-MAR-16:04 | 4146.24 | 27-MAR-16:04 | 1004.18 | 28-MAR-19:00 | 1254.39 | 27-MAR-11:00 | 0.00 | 01-MAR-00:10 |
| April | 0.699098E+10 | 0.184711E+10 | 719.50 | 0.588361E+10 | 0.110737E+10 | 0.00 | 0.44 | 28-APR-15:10 | 0.00 | 05-APR-05:05 | 5623.86 | 30-APR-16:15 | 4676.97 | 28-APR-12:50 | 1823.43 | 30-APR-16:15 | 1565.48 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.105080E+11 | 0.291646E+10 | 744.00 | 0.862563E+10 | 0.188236E+10 | 0.00 | 0.60 | 21-MAY-13:00 | 0.14 | 03-MAY-05:40 | 7298.85 | 21-MAY-13:00 | 6550.64 | 21-MAY-13:00 | 2289.36 | 29-MAY-14:00 | 2193.91 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.126640E+11 | 0.352064E+10 | 720.00 | 0.934285E+10 | 0.332116E+10 | 0.00 | 0.59 | 09-JUN-14:20 | 0.20 | 02-JUN-05:00 | 7352.40 | 12-JUN-15:10 | 5875.29 | 09-JUN-16:30 | 2706.77 | 08-JUN-14:00 | 2223.36 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.149151E+11 | 0.423156E+10 | 744.00 | 0.105845E+11 | 0.433058E+10 | 0.00 | 0.63 | 30-JUL-17:10 | 0.20 | 03-JUL-06:00 | 8500.50 | 30-JUL-17:10 | 5959.04 | 21-JUL-17:04 | 3301.69 | 30-JUL-17:10 | 2397.15 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.152859E+11 | 0.434175E+10 | 744.00 | 0.106413E+11 | 0.464465E+10 | 0.00 | 0.67 | 10-AUG-16:10 | 0.27 | 15-AUG-07:00 | 8888.14 | 22-AUG-17:10 | 5890.66 | 16-AUG-12:00 | 3781.50 | 22-AUG-17:10 | 2576.64 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.125747E+11 | 0.345136E+10 | 720.00 | 0.877529E+10 | 0.379939E+10 | 0.00 | 0.57 | 09-SEP-16:02 | 0.19 | 26-SEP-06:00 | 7590.44 | 09-SEP-16:02 | 5273.40 | 04-SEP-16:40 | 3044.35 | 08-SEP-17:20 | 2086.91 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.978057E+10 | 0.261439E+10 | 744.00 | 0.738667E+10 | 0.239391E+10 | 0.00 | 0.48 | 07-OCT-16:10 | 0.12 | 21-OCT-07:00 | 6342.30 | 07-OCT-16:10 | 4492.30 | 09-OCT-16:09 | 2871.98 | 07-OCT-10:30 | 1744.55 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.640860E+10 | 0.165977E+10 | 718.84 | 0.513767E+10 | 0.127093E+10 | 0.00 | 0.41 | 01-NOV-16:01 | 0.00 | 22-NOV-06:05 | 5366.34 | 01-NOV-16:01 | 3589.09 | 01-NOV-16:03 | 1777.87 | 01-NOV-16:01 | 1436.27 | 01-NOV-16:01 | 0.00 | 01-NOV-00:10 |
| December | 0.369450E+10 | 0.931079E+09 | 712.59 | 0.303491E+10 | 0.659592E+09 | 0.00 | 0.26 | 05-DEC-17:04 | 0.00 | 08-DEC-06:05 | 3375.52 | 05-DEC-17:04 | 2595.45 | 10-DEC-13:00 | 1106.84 | 05-DEC-17:02 | 830.57 | 05-DEC-17:04 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.103157E+12 | 0.281635E+11 | 8591.02 | 0.783755E+11 | 0.247811E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.237267E+10 | 0.601224E+09 | 639.19 | 0.207172E+10 | 0.300949E+09 | 0.00 | 0.21 | 0.00 | 2685.65 | 2204.30 | 788.59 | 672.60 | 0.00 | |||||||
| Maximum of Months | 0.152859E+11 | 0.434175E+10 | 744.00 | 0.106413E+11 | 0.464465E+10 | 0.00 | 0.67 | 0.27 | 8888.14 | 6550.64 | 3781.50 | 2576.64 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.396978E+10 | 0.100148E+10 | 722.55 | 0.355666E+10 | 0.413116E+09 | 0.00 | 0.29 | 28-JAN-14:00 | 0.00 | 01-JAN-04:40 | 3771.89 | 29-JAN-17:05 | 3622.86 | 28-JAN-13:50 | 840.87 | 30-JAN-15:40 | 973.06 | 28-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.436783E+10 | 0.110596E+10 | 660.02 | 0.378195E+10 | 0.585883E+09 | 0.00 | 0.38 | 05-FEB-14:00 | 0.00 | 01-FEB-08:35 | 4827.15 | 05-FEB-14:00 | 4553.06 | 05-FEB-14:00 | 1107.31 | 07-FEB-16:20 | 1334.71 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.578233E+10 | 0.149509E+10 | 736.62 | 0.514296E+10 | 0.639372E+09 | 0.00 | 0.41 | 01-MAR-15:10 | 0.00 | 04-MAR-07:40 | 4891.22 | 01-MAR-15:10 | 4891.22 | 01-MAR-15:10 | 1024.88 | 28-MAR-19:00 | 1458.61 | 01-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.748282E+10 | 0.197700E+10 | 720.00 | 0.634064E+10 | 0.114218E+10 | 0.00 | 0.45 | 28-APR-15:10 | 0.00 | 05-APR-06:00 | 6061.57 | 30-APR-16:15 | 4985.34 | 28-APR-12:50 | 1921.30 | 30-APR-16:15 | 1631.68 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.105000E+11 | 0.291977E+10 | 744.00 | 0.862708E+10 | 0.187288E+10 | 0.00 | 0.59 | 21-MAY-13:00 | 0.13 | 03-MAY-06:00 | 7454.21 | 21-MAY-13:00 | 6663.49 | 21-MAY-13:00 | 2339.31 | 29-MAY-14:00 | 2201.95 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.124310E+11 | 0.346502E+10 | 720.00 | 0.913959E+10 | 0.329142E+10 | 0.00 | 0.56 | 09-JUN-14:20 | 0.18 | 22-JUN-08:00 | 7242.64 | 09-JUN-12:50 | 5718.84 | 09-JUN-16:07 | 2678.03 | 08-JUN-14:00 | 2205.93 | 09-JUN-13:00 | 0.00 | 01-JUN-00:10 |
| July | 0.148580E+11 | 0.422591E+10 | 744.00 | 0.105367E+11 | 0.432126E+10 | 0.00 | 0.63 | 30-JUL-16:10 | 0.20 | 03-JUL-06:00 | 8678.99 | 30-JUL-17:10 | 5890.31 | 21-JUL-17:04 | 3355.07 | 30-JUL-17:10 | 2437.78 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.155608E+11 | 0.442764E+10 | 744.00 | 0.108992E+11 | 0.466162E+10 | 0.00 | 0.66 | 10-AUG-16:10 | 0.26 | 15-AUG-07:08 | 8993.75 | 22-AUG-17:10 | 6177.30 | 16-AUG-12:00 | 3762.01 | 22-AUG-17:10 | 2613.94 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.134700E+11 | 0.369866E+10 | 720.00 | 0.958219E+10 | 0.388784E+10 | 0.00 | 0.59 | 09-SEP-16:02 | 0.19 | 26-SEP-06:00 | 8234.53 | 09-SEP-16:02 | 5795.06 | 04-SEP-16:02 | 3060.57 | 08-SEP-18:00 | 2259.34 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.112707E+11 | 0.301030E+10 | 744.00 | 0.875389E+10 | 0.251681E+10 | 0.00 | 0.53 | 07-OCT-13:30 | 0.13 | 21-OCT-07:00 | 7282.44 | 07-OCT-13:10 | 5572.11 | 09-OCT-15:10 | 3144.47 | 07-OCT-10:30 | 2010.01 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.812774E+10 | 0.209909E+10 | 720.00 | 0.671416E+10 | 0.141358E+10 | 0.00 | 0.49 | 01-NOV-14:10 | 0.00 | 22-NOV-06:40 | 6590.30 | 01-NOV-14:10 | 4827.14 | 05-NOV-13:30 | 1896.03 | 01-NOV-15:10 | 1780.79 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.534963E+10 | 0.134321E+10 | 735.35 | 0.454009E+10 | 0.809538E+09 | 0.00 | 0.34 | 04-DEC-13:20 | 0.00 | 13-DEC-07:40 | 4561.92 | 05-DEC-14:00 | 3994.41 | 03-DEC-13:00 | 1291.75 | 25-DEC-11:30 | 1162.96 | 04-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.113171E+12 | 0.307691E+11 | 8710.55 | 0.876151E+11 | 0.255555E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.396978E+10 | 0.100148E+10 | 660.02 | 0.355666E+10 | 0.413116E+09 | 0.00 | 0.29 | 0.00 | 3771.89 | 3622.86 | 840.87 | 973.06 | 0.00 | |||||||
| Maximum of Months | 0.155608E+11 | 0.442764E+10 | 744.00 | 0.108992E+11 | 0.466162E+10 | 0.00 | 0.66 | 0.26 | 8993.75 | 6663.49 | 3762.01 | 2613.94 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.397234E+10 | 0.100210E+10 | 722.67 | 0.355903E+10 | 0.413310E+09 | 0.00 | 0.29 | 28-JAN-14:00 | 0.00 | 01-JAN-04:40 | 3767.81 | 29-JAN-17:05 | 3629.91 | 28-JAN-13:50 | 841.09 | 30-JAN-15:40 | 974.68 | 28-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.436874E+10 | 0.110617E+10 | 660.02 | 0.378279E+10 | 0.585955E+09 | 0.00 | 0.38 | 05-FEB-14:00 | 0.00 | 01-FEB-08:35 | 4833.12 | 05-FEB-14:00 | 4558.93 | 05-FEB-14:00 | 1106.22 | 07-FEB-16:20 | 1336.22 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.578088E+10 | 0.149471E+10 | 736.62 | 0.514159E+10 | 0.639287E+09 | 0.00 | 0.41 | 01-MAR-15:10 | 0.00 | 04-MAR-07:40 | 4886.87 | 01-MAR-15:10 | 4886.87 | 01-MAR-15:10 | 1024.79 | 28-MAR-19:00 | 1457.40 | 01-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.748566E+10 | 0.197773E+10 | 720.00 | 0.634332E+10 | 0.114235E+10 | 0.00 | 0.45 | 28-APR-15:10 | 0.00 | 05-APR-06:00 | 6059.02 | 30-APR-16:15 | 4996.29 | 28-APR-12:50 | 1920.47 | 30-APR-16:15 | 1632.24 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.105038E+11 | 0.292078E+10 | 744.00 | 0.863074E+10 | 0.187307E+10 | 0.00 | 0.59 | 21-MAY-13:00 | 0.13 | 03-MAY-06:00 | 7463.93 | 21-MAY-13:00 | 6672.62 | 21-MAY-13:00 | 2339.85 | 29-MAY-14:00 | 2204.41 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.124321E+11 | 0.346524E+10 | 720.00 | 0.914059E+10 | 0.329154E+10 | 0.00 | 0.56 | 09-JUN-14:20 | 0.18 | 22-JUN-08:00 | 7250.62 | 09-JUN-12:50 | 5712.37 | 09-JUN-16:07 | 2677.48 | 08-JUN-14:00 | 2207.89 | 09-JUN-13:00 | 0.00 | 01-JUN-00:10 |
| July | 0.148594E+11 | 0.422614E+10 | 744.00 | 0.105380E+11 | 0.432143E+10 | 0.00 | 0.63 | 30-JUL-16:10 | 0.20 | 03-JUL-06:00 | 8676.52 | 30-JUL-17:10 | 5884.43 | 21-JUL-17:04 | 3354.66 | 30-JUL-17:10 | 2437.13 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.155625E+11 | 0.442793E+10 | 744.00 | 0.109007E+11 | 0.466183E+10 | 0.00 | 0.66 | 10-AUG-16:10 | 0.26 | 15-AUG-07:08 | 8985.78 | 22-AUG-17:10 | 6188.05 | 16-AUG-12:00 | 3760.45 | 22-AUG-17:10 | 2612.00 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.134713E+11 | 0.369889E+10 | 720.00 | 0.958338E+10 | 0.388793E+10 | 0.00 | 0.59 | 09-SEP-16:02 | 0.19 | 26-SEP-06:00 | 8226.77 | 09-SEP-16:02 | 5790.02 | 04-SEP-16:02 | 3059.28 | 08-SEP-18:00 | 2257.21 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.112730E+11 | 0.301080E+10 | 744.00 | 0.875588E+10 | 0.251713E+10 | 0.00 | 0.53 | 07-OCT-13:30 | 0.13 | 21-OCT-06:00 | 7288.40 | 07-OCT-13:10 | 5570.29 | 09-OCT-15:10 | 3146.90 | 07-OCT-10:30 | 2011.10 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.812891E+10 | 0.209933E+10 | 720.00 | 0.671511E+10 | 0.141380E+10 | 0.00 | 0.49 | 01-NOV-14:10 | 0.00 | 22-NOV-06:40 | 6591.87 | 01-NOV-14:10 | 4832.04 | 05-NOV-13:30 | 1895.11 | 01-NOV-15:10 | 1781.11 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.534967E+10 | 0.134320E+10 | 735.43 | 0.454008E+10 | 0.809587E+09 | 0.00 | 0.34 | 04-DEC-13:20 | 0.00 | 13-DEC-07:40 | 4564.03 | 05-DEC-14:00 | 4000.08 | 03-DEC-13:00 | 1293.11 | 25-DEC-11:30 | 1164.40 | 04-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.113188E+12 | 0.307730E+11 | 8710.76 | 0.876312E+11 | 0.255572E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.397234E+10 | 0.100210E+10 | 660.02 | 0.355903E+10 | 0.413310E+09 | 0.00 | 0.29 | 0.00 | 3767.81 | 3629.91 | 841.09 | 974.68 | 0.00 | |||||||
| Maximum of Months | 0.155625E+11 | 0.442793E+10 | 744.00 | 0.109007E+11 | 0.466183E+10 | 0.00 | 0.66 | 0.26 | 8985.78 | 6672.62 | 3760.45 | 2612.00 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.145348E+10 | 0.366980E+09 | 420.71 | 0.129118E+10 | 0.162298E+09 | 0.00 | 0.31 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 | 2718.93 | 29-JAN-16:10 | 2424.91 | 22-JAN-15:30 | 524.06 | 24-JAN-13:50 | 685.90 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.195119E+10 | 0.497194E+09 | 440.21 | 0.170036E+10 | 0.250830E+09 | 0.00 | 0.44 | 05-FEB-15:00 | 0.00 | 01-FEB-00:10 | 3855.90 | 07-FEB-15:40 | 3558.52 | 05-FEB-15:00 | 887.35 | 07-FEB-16:20 | 1028.95 | 05-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.315008E+10 | 0.820689E+09 | 613.49 | 0.282405E+10 | 0.326029E+09 | 0.00 | 0.54 | 01-MAR-15:30 | 0.00 | 03-MAR-06:05 | 4344.62 | 01-MAR-15:30 | 4344.62 | 01-MAR-15:30 | 714.98 | 28-MAR-11:50 | 1270.60 | 01-MAR-15:30 | 0.00 | 01-MAR-00:10 |
| April | 0.468435E+10 | 0.124811E+10 | 689.34 | 0.401862E+10 | 0.665731E+09 | 0.00 | 0.59 | 28-APR-15:10 | 0.00 | 01-APR-03:20 | 5178.97 | 28-APR-15:10 | 4400.59 | 28-APR-13:00 | 1585.16 | 30-APR-15:40 | 1445.51 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.736249E+10 | 0.205499E+10 | 744.00 | 0.616252E+10 | 0.119998E+10 | 0.00 | 0.80 | 21-MAY-13:00 | 0.05 | 01-MAY-06:00 | 6982.39 | 21-MAY-13:00 | 6192.01 | 21-MAY-13:00 | 1982.85 | 29-MAY-13:50 | 1990.33 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.892300E+10 | 0.248955E+10 | 720.00 | 0.672284E+10 | 0.220016E+10 | 0.00 | 0.75 | 09-JUN-16:10 | 0.13 | 07-JUN-05:00 | 6481.87 | 12-JUN-15:10 | 5369.06 | 09-JUN-16:01 | 2180.73 | 08-JUN-13:50 | 1919.58 | 09-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.107849E+11 | 0.306269E+10 | 744.00 | 0.788715E+10 | 0.289777E+10 | 0.00 | 0.81 | 30-JUL-16:10 | 0.15 | 03-JUL-06:00 | 7572.54 | 30-JUL-16:10 | 5387.74 | 21-JUL-16:12 | 2620.71 | 30-JUL-17:00 | 2089.49 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.112498E+11 | 0.319329E+10 | 744.00 | 0.811321E+10 | 0.313660E+10 | 0.00 | 0.85 | 10-AUG-16:01 | 0.21 | 15-AUG-07:10 | 7635.64 | 22-AUG-17:10 | 5435.72 | 10-AUG-16:01 | 3042.52 | 22-AUG-17:10 | 2222.81 | 10-AUG-16:01 | 0.00 | 01-AUG-00:10 |
| September | 0.926641E+10 | 0.254934E+10 | 720.00 | 0.673112E+10 | 0.253528E+10 | 0.00 | 0.73 | 09-SEP-16:02 | 0.12 | 25-SEP-06:00 | 6837.33 | 09-SEP-16:02 | 5125.26 | 04-SEP-16:10 | 2302.99 | 09-SEP-16:02 | 1842.94 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.717910E+10 | 0.193069E+10 | 744.00 | 0.564570E+10 | 0.153340E+10 | 0.00 | 0.63 | 07-OCT-15:20 | 0.04 | 21-OCT-07:00 | 5798.00 | 07-OCT-16:10 | 4744.05 | 19-OCT-15:10 | 2225.33 | 07-OCT-10:30 | 1573.69 | 07-OCT-15:20 | 0.00 | 01-OCT-00:10 |
| November | 0.454344E+10 | 0.118416E+10 | 685.93 | 0.376542E+10 | 0.778026E+09 | 0.00 | 0.57 | 01-NOV-14:20 | 0.00 | 16-NOV-06:05 | 5240.71 | 01-NOV-15:10 | 3836.19 | 05-NOV-15:10 | 1451.97 | 01-NOV-15:10 | 1391.23 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.233652E+10 | 0.589322E+09 | 511.75 | 0.197974E+10 | 0.356775E+09 | 0.00 | 0.38 | 03-DEC-14:40 | 0.00 | 01-DEC-02:40 | 3398.13 | 05-DEC-15:10 | 2870.17 | 03-DEC-14:30 | 878.90 | 05-DEC-15:30 | 850.69 | 03-DEC-14:50 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.728848E+11 | 0.199870E+11 | 7777.43 | 0.568419E+11 | 0.160429E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.145348E+10 | 0.366980E+09 | 420.71 | 0.129118E+10 | 0.162298E+09 | 0.00 | 0.31 | 0.00 | 2718.93 | 2424.91 | 524.06 | 685.90 | 0.00 | |||||||
| Maximum of Months | 0.112498E+11 | 0.319329E+10 | 744.00 | 0.811321E+10 | 0.313660E+10 | 0.00 | 0.85 | 0.21 | 7635.64 | 6192.01 | 3042.52 | 2222.81 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.731376E+09 | 0.185423E+09 | 351.50 | 0.626487E+09 | 0.104889E+09 | 0.00 | 0.24 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 | 2050.40 | 29-JAN-16:10 | 1686.76 | 29-JAN-16:10 | 468.65 | 30-JAN-15:30 | 520.33 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.133626E+10 | 0.342431E+09 | 407.33 | 0.113440E+10 | 0.201859E+09 | 0.00 | 0.36 | 07-FEB-16:10 | 0.00 | 01-FEB-00:10 | 3143.98 | 07-FEB-16:10 | 2768.57 | 06-FEB-15:20 | 826.33 | 07-FEB-16:20 | 800.96 | 07-FEB-16:10 | 0.00 | 01-FEB-00:10 |
| March | 0.266976E+10 | 0.698793E+09 | 598.64 | 0.236934E+10 | 0.300423E+09 | 0.00 | 0.49 | 01-MAR-15:30 | 0.00 | 03-MAR-06:05 | 3797.13 | 01-MAR-15:30 | 3797.13 | 01-MAR-15:30 | 704.44 | 28-MAR-11:50 | 1120.21 | 01-MAR-15:30 | 0.00 | 01-MAR-00:10 |
| April | 0.441662E+10 | 0.117795E+10 | 688.80 | 0.376777E+10 | 0.648843E+09 | 0.00 | 0.58 | 28-APR-15:10 | 0.00 | 01-APR-03:00 | 5006.34 | 28-APR-15:10 | 4177.62 | 28-APR-14:10 | 1523.43 | 30-APR-15:40 | 1398.47 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.736417E+10 | 0.205293E+10 | 744.00 | 0.615907E+10 | 0.120511E+10 | 0.00 | 0.81 | 21-MAY-13:00 | 0.06 | 01-MAY-06:00 | 6880.52 | 21-MAY-13:00 | 6110.06 | 21-MAY-13:00 | 1953.77 | 29-MAY-13:50 | 1960.29 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.904583E+10 | 0.251889E+10 | 720.00 | 0.683182E+10 | 0.221401E+10 | 0.00 | 0.77 | 09-JUN-16:12 | 0.13 | 07-JUN-05:00 | 6551.68 | 12-JUN-15:10 | 5457.50 | 09-JUN-16:15 | 2192.50 | 08-JUN-13:50 | 1922.91 | 09-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.108100E+11 | 0.306492E+10 | 744.00 | 0.790859E+10 | 0.290145E+10 | 0.00 | 0.81 | 30-JUL-16:10 | 0.15 | 03-JUL-06:00 | 7393.59 | 30-JUL-16:10 | 5418.11 | 21-JUL-16:30 | 2592.35 | 30-JUL-17:02 | 2060.38 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.110937E+11 | 0.314667E+10 | 744.00 | 0.796412E+10 | 0.312959E+10 | 0.00 | 0.85 | 10-AUG-16:01 | 0.21 | 15-AUG-07:00 | 7563.52 | 22-AUG-17:10 | 5333.77 | 10-AUG-16:01 | 3046.26 | 22-AUG-17:10 | 2195.36 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.878447E+10 | 0.241868E+10 | 720.00 | 0.628853E+10 | 0.249594E+10 | 0.00 | 0.70 | 09-SEP-16:02 | 0.12 | 25-SEP-06:00 | 6419.62 | 09-SEP-16:02 | 4789.74 | 04-SEP-16:17 | 2271.74 | 08-SEP-17:10 | 1736.17 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.638283E+10 | 0.172040E+10 | 744.00 | 0.490699E+10 | 0.147583E+10 | 0.00 | 0.58 | 07-OCT-16:10 | 0.04 | 21-OCT-07:00 | 5212.44 | 07-OCT-16:10 | 4058.06 | 19-OCT-15:20 | 2078.46 | 07-OCT-10:30 | 1418.05 | 07-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.363923E+10 | 0.952801E+09 | 678.53 | 0.293482E+10 | 0.704413E+09 | 0.00 | 0.49 | 01-NOV-15:10 | 0.00 | 16-NOV-06:05 | 4424.53 | 01-NOV-15:10 | 3040.27 | 01-NOV-15:10 | 1384.26 | 01-NOV-15:10 | 1171.78 | 01-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.152206E+10 | 0.385904E+09 | 468.63 | 0.124200E+10 | 0.280058E+09 | 0.00 | 0.28 | 05-DEC-16:10 | 0.00 | 01-DEC-02:70 | 2518.86 | 05-DEC-16:10 | 1959.79 | 10-DEC-13:40 | 782.91 | 05-DEC-16:10 | 623.91 | 05-DEC-16:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.677964E+11 | 0.186658E+11 | 7609.42 | 0.521339E+11 | 0.156624E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.731376E+09 | 0.185423E+09 | 351.50 | 0.626487E+09 | 0.104889E+09 | 0.00 | 0.24 | 0.00 | 2050.40 | 1686.76 | 468.65 | 520.33 | 0.00 | |||||||
| Maximum of Months | 0.110937E+11 | 0.314667E+10 | 744.00 | 0.796412E+10 | 0.312959E+10 | 0.00 | 0.85 | 0.21 | 7563.52 | 6110.06 | 3046.26 | 2195.36 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.145788E+10 | 0.367826E+09 | 427.84 | 0.129648E+10 | 0.161406E+09 | 0.00 | 0.32 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 | 2672.54 | 29-JAN-12:00 | 2407.65 | 28-JAN-14:00 | 543.09 | 29-JAN-10:10 | 686.43 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.194147E+10 | 0.494351E+09 | 443.92 | 0.169288E+10 | 0.248588E+09 | 0.00 | 0.45 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 | 3656.48 | 05-FEB-14:00 | 3458.41 | 05-FEB-14:00 | 841.65 | 07-FEB-16:20 | 1000.36 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.311896E+10 | 0.812235E+09 | 616.77 | 0.279601E+10 | 0.322951E+09 | 0.00 | 0.55 | 27-MAR-12:40 | 0.00 | 03-MAR-06:05 | 4169.76 | 27-MAR-13:00 | 4169.76 | 27-MAR-13:00 | 729.95 | 28-MAR-11:50 | 1219.59 | 27-MAR-12:40 | 0.00 | 01-MAR-00:10 |
| April | 0.472669E+10 | 0.125769E+10 | 690.75 | 0.406091E+10 | 0.665782E+09 | 0.00 | 0.62 | 28-APR-12:30 | 0.00 | 01-APR-03:00 | 5098.09 | 28-APR-14:20 | 4617.61 | 28-APR-13:00 | 1543.68 | 30-APR-15:40 | 1423.20 | 28-APR-14:20 | 0.00 | 01-APR-00:10 |
| May | 0.741738E+10 | 0.206557E+10 | 744.00 | 0.621837E+10 | 0.119901E+10 | 0.00 | 0.86 | 21-MAY-13:00 | 0.06 | 01-MAY-05:40 | 7148.65 | 21-MAY-13:00 | 6358.26 | 21-MAY-13:00 | 1964.48 | 29-MAY-13:40 | 2019.86 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.893952E+10 | 0.248711E+10 | 720.00 | 0.673946E+10 | 0.220006E+10 | 0.00 | 0.76 | 09-JUN-13:00 | 0.13 | 07-JUN-05:00 | 6383.50 | 09-JUN-12:30 | 4943.19 | 09-JUN-15:10 | 2129.72 | 08-JUN-13:50 | 1880.53 | 09-JUN-13:00 | 0.00 | 01-JUN-00:10 |
| July | 0.108031E+11 | 0.305795E+10 | 744.00 | 0.790717E+10 | 0.289588E+10 | 0.00 | 0.82 | 30-JUL-16:10 | 0.15 | 03-JUL-06:00 | 7307.77 | 30-JUL-16:10 | 5275.78 | 30-JUL-14:00 | 2594.45 | 30-JUL-17:00 | 2013.28 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.112733E+11 | 0.318896E+10 | 744.00 | 0.813686E+10 | 0.313646E+10 | 0.00 | 0.84 | 10-AUG-16:01 | 0.22 | 15-AUG-06:40 | 7252.65 | 22-AUG-17:10 | 5558.02 | 16-AUG-12:00 | 2988.20 | 22-AUG-17:10 | 2098.91 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.928322E+10 | 0.254670E+10 | 720.00 | 0.674969E+10 | 0.253353E+10 | 0.00 | 0.72 | 09-SEP-16:02 | 0.12 | 25-SEP-06:00 | 6404.22 | 09-SEP-16:02 | 4924.12 | 04-SEP-14:00 | 2240.27 | 09-SEP-16:02 | 1726.98 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.721383E+10 | 0.193447E+10 | 744.00 | 0.567415E+10 | 0.153968E+10 | 0.00 | 0.65 | 07-OCT-13:30 | 0.05 | 21-OCT-06:15 | 5682.17 | 07-OCT-13:20 | 4501.29 | 09-OCT-13:50 | 2283.95 | 07-OCT-10:20 | 1546.16 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.455760E+10 | 0.118519E+10 | 687.44 | 0.377528E+10 | 0.782317E+09 | 0.00 | 0.58 | 01-NOV-14:00 | 0.00 | 16-NOV-06:05 | 5079.87 | 01-NOV-14:10 | 3739.16 | 05-NOV-13:30 | 1404.02 | 01-NOV-15:10 | 1355.86 | 01-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.231921E+10 | 0.584481E+09 | 517.07 | 0.196434E+10 | 0.354877E+09 | 0.00 | 0.38 | 04-DEC-13:20 | 0.00 | 01-DEC-02:30 | 3253.56 | 05-DEC-13:50 | 2854.07 | 03-DEC-13:20 | 830.04 | 05-DEC-15:20 | 820.04 | 04-DEC-13:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.730522E+11 | 0.199825E+11 | 7799.79 | 0.570116E+11 | 0.160405E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.145788E+10 | 0.367826E+09 | 427.84 | 0.129648E+10 | 0.161406E+09 | 0.00 | 0.32 | 0.00 | 2672.54 | 2407.65 | 543.09 | 686.43 | 0.00 | |||||||
| Maximum of Months | 0.112733E+11 | 0.318896E+10 | 744.00 | 0.813686E+10 | 0.313646E+10 | 0.00 | 0.86 | 0.22 | 7307.77 | 6358.26 | 2988.20 | 2098.91 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.724741E+09 | 0.183722E+09 | 358.67 | 0.621367E+09 | 0.103374E+09 | 0.00 | 0.24 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 | 1952.50 | 29-JAN-12:00 | 1651.11 | 29-JAN-12:00 | 471.39 | 30-JAN-15:30 | 506.46 | 29-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.132141E+10 | 0.338633E+09 | 410.67 | 0.112240E+10 | 0.199012E+09 | 0.00 | 0.34 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 | 2805.16 | 07-FEB-16:10 | 2547.79 | 06-FEB-15:00 | 770.03 | 07-FEB-16:20 | 739.56 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.263761E+10 | 0.690360E+09 | 602.92 | 0.234046E+10 | 0.297146E+09 | 0.00 | 0.50 | 27-MAR-11:40 | 0.00 | 03-MAR-06:05 | 3696.22 | 27-MAR-13:00 | 3696.22 | 27-MAR-13:00 | 720.70 | 28-MAR-11:50 | 1091.19 | 27-MAR-12:40 | 0.00 | 01-MAR-00:10 |
| April | 0.445896E+10 | 0.118785E+10 | 690.00 | 0.380995E+10 | 0.649009E+09 | 0.00 | 0.60 | 28-APR-14:20 | 0.00 | 01-APR-02:50 | 4896.83 | 28-APR-14:20 | 4386.82 | 28-APR-13:00 | 1480.23 | 30-APR-15:40 | 1368.84 | 28-APR-14:20 | 0.00 | 01-APR-00:10 |
| May | 0.741908E+10 | 0.206326E+10 | 744.00 | 0.621506E+10 | 0.120402E+10 | 0.00 | 0.86 | 21-MAY-13:00 | 0.06 | 01-MAY-05:40 | 7052.99 | 21-MAY-13:00 | 6281.33 | 21-MAY-13:00 | 1934.28 | 29-MAY-13:40 | 1991.16 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.906222E+10 | 0.251586E+10 | 720.00 | 0.684847E+10 | 0.221375E+10 | 0.00 | 0.78 | 09-JUN-12:50 | 0.13 | 07-JUN-05:00 | 6402.86 | 09-JUN-12:30 | 5009.99 | 09-JUN-16:08 | 2140.21 | 08-JUN-13:50 | 1879.33 | 09-JUN-13:00 | 0.00 | 01-JUN-00:10 |
| July | 0.108281E+11 | 0.305968E+10 | 744.00 | 0.792857E+10 | 0.289952E+10 | 0.00 | 0.83 | 14-JUL-14:00 | 0.16 | 03-JUL-06:00 | 7129.67 | 30-JUL-16:10 | 5148.17 | 21-JUL-14:10 | 2567.32 | 30-JUL-17:02 | 2013.34 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.111173E+11 | 0.314229E+10 | 744.00 | 0.798783E+10 | 0.312949E+10 | 0.00 | 0.84 | 10-AUG-16:10 | 0.23 | 15-AUG-06:40 | 7181.35 | 22-AUG-17:10 | 5356.54 | 16-AUG-12:00 | 2991.53 | 22-AUG-17:10 | 2071.94 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.880155E+10 | 0.241683E+10 | 720.00 | 0.630718E+10 | 0.249437E+10 | 0.00 | 0.68 | 09-SEP-16:02 | 0.12 | 25-SEP-06:00 | 5988.15 | 09-SEP-16:02 | 4447.17 | 04-SEP-14:10 | 2219.99 | 08-SEP-17:20 | 1627.98 | 08-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.641883E+10 | 0.172566E+10 | 744.00 | 0.493524E+10 | 0.148360E+10 | 0.00 | 0.57 | 07-OCT-13:30 | 0.04 | 21-OCT-06:15 | 4907.79 | 07-OCT-13:30 | 3734.06 | 19-OCT-15:10 | 2150.78 | 07-OCT-10:20 | 1346.72 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.365305E+10 | 0.954705E+09 | 680.50 | 0.294308E+10 | 0.709970E+09 | 0.00 | 0.49 | 01-NOV-14:10 | 0.00 | 16-NOV-06:05 | 4175.61 | 01-NOV-14:10 | 2896.72 | 01-NOV-14:10 | 1326.12 | 01-NOV-15:10 | 1123.48 | 01-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.149806E+10 | 0.379729E+09 | 476.81 | 0.122100E+10 | 0.277065E+09 | 0.00 | 0.28 | 10-DEC-13:00 | 0.00 | 01-DEC-02:70 | 2224.05 | 05-DEC-13:50 | 1991.68 | 10-DEC-13:00 | 716.59 | 05-DEC-16:10 | 592.00 | 10-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.679409E+11 | 0.186586E+11 | 7635.56 | 0.522806E+11 | 0.156603E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.724741E+09 | 0.183722E+09 | 358.67 | 0.621367E+09 | 0.103374E+09 | 0.00 | 0.24 | 0.00 | 1952.50 | 1651.11 | 471.39 | 506.46 | 0.00 | |||||||
| Maximum of Months | 0.111173E+11 | 0.314229E+10 | 744.00 | 0.798783E+10 | 0.312949E+10 | 0.00 | 0.86 | 0.23 | 7181.35 | 6281.33 | 2991.53 | 2071.94 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.686753E+09 | 0.174012E+09 | 399.86 | 0.585671E+09 | 0.101082E+09 | 0.00 | 0.22 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 | 1558.80 | 29-JAN-16:10 | 1337.97 | 23-JAN-14:00 | 414.63 | 30-JAN-16:10 | 396.33 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.120011E+10 | 0.306940E+09 | 454.58 | 0.101179E+10 | 0.188319E+09 | 0.00 | 0.31 | 07-FEB-16:10 | 0.00 | 01-FEB-00:10 | 2300.63 | 07-FEB-16:20 | 2066.24 | 06-FEB-15:10 | 597.48 | 07-FEB-16:20 | 590.36 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.229505E+10 | 0.599899E+09 | 630.94 | 0.202788E+10 | 0.267167E+09 | 0.00 | 0.42 | 27-MAR-13:00 | 0.00 | 03-MAR-06:05 | 2757.27 | 27-MAR-13:00 | 2757.27 | 27-MAR-13:00 | 535.22 | 28-MAR-19:00 | 821.00 | 27-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.372126E+10 | 0.991247E+09 | 702.69 | 0.316384E+10 | 0.557422E+09 | 0.00 | 0.51 | 28-APR-15:10 | 0.00 | 01-APR-05:00 | 3653.23 | 28-APR-15:10 | 3224.93 | 28-APR-13:00 | 1087.10 | 30-APR-15:40 | 1032.98 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.606972E+10 | 0.169209E+10 | 744.00 | 0.505362E+10 | 0.101610E+10 | 0.00 | 0.70 | 21-MAY-13:00 | 0.08 | 01-MAY-06:00 | 4947.64 | 21-MAY-13:00 | 4448.10 | 21-MAY-13:00 | 1419.15 | 29-MAY-13:50 | 1435.51 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.738841E+10 | 0.205990E+10 | 720.00 | 0.555893E+10 | 0.182949E+10 | 0.00 | 0.68 | 09-JUN-14:20 | 0.15 | 07-JUN-05:00 | 4839.80 | 09-JUN-13:00 | 3954.28 | 09-JUN-16:17 | 1625.22 | 08-JUN-13:50 | 1456.36 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.883270E+10 | 0.250862E+10 | 744.00 | 0.643194E+10 | 0.240076E+10 | 0.00 | 0.73 | 14-JUL-14:00 | 0.16 | 03-JUL-06:00 | 5460.44 | 30-JUL-16:10 | 4023.44 | 21-JUL-16:30 | 1953.39 | 30-JUL-17:10 | 1568.13 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.902993E+10 | 0.256699E+10 | 744.00 | 0.645158E+10 | 0.257835E+10 | 0.00 | 0.76 | 10-AUG-16:10 | 0.23 | 15-AUG-07:00 | 5582.54 | 22-AUG-17:10 | 3999.16 | 16-AUG-12:00 | 2239.29 | 22-AUG-17:10 | 1649.10 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.721964E+10 | 0.198921E+10 | 720.00 | 0.514189E+10 | 0.207775E+10 | 0.00 | 0.62 | 09-SEP-16:02 | 0.14 | 30-SEP-05:00 | 4762.49 | 09-SEP-16:02 | 3524.06 | 04-SEP-16:17 | 1746.95 | 08-SEP-17:20 | 1302.94 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.535845E+10 | 0.144200E+10 | 744.00 | 0.409331E+10 | 0.126514E+10 | 0.00 | 0.53 | 07-OCT-16:10 | 0.05 | 21-OCT-07:00 | 3950.17 | 07-OCT-16:10 | 2917.72 | 09-OCT-15:10 | 1686.31 | 07-OCT-10:30 | 1083.42 | 07-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.315521E+10 | 0.824020E+09 | 692.28 | 0.253373E+10 | 0.621473E+09 | 0.00 | 0.44 | 01-NOV-14:10 | 0.00 | 22-NOV-02:20 | 3302.02 | 01-NOV-15:10 | 2282.38 | 01-NOV-14:10 | 1038.98 | 01-NOV-15:10 | 891.98 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.140105E+10 | 0.354660E+09 | 523.17 | 0.113888E+10 | 0.262173E+09 | 0.00 | 0.25 | 10-DEC-13:00 | 0.00 | 01-DEC-03:00 | 1880.28 | 05-DEC-16:10 | 1612.16 | 10-DEC-13:30 | 597.70 | 05-DEC-16:10 | 483.83 | 10-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.563583E+11 | 0.155096E+11 | 7819.53 | 0.431931E+11 | 0.131652E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.686753E+09 | 0.174012E+09 | 399.86 | 0.585671E+09 | 0.101082E+09 | 0.00 | 0.22 | 0.00 | 1558.80 | 1337.97 | 414.63 | 396.33 | 0.00 | |||||||
| Maximum of Months | 0.902993E+10 | 0.256699E+10 | 744.00 | 0.645158E+10 | 0.257835E+10 | 0.00 | 0.76 | 0.23 | 5582.54 | 4448.10 | 2239.29 | 1649.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.690273E+09 | 0.174906E+09 | 400.42 | 0.588910E+09 | 0.101363E+09 | 0.00 | 0.22 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 | 1555.81 | 29-JAN-16:10 | 1338.57 | 23-JAN-14:00 | 414.81 | 30-JAN-16:10 | 395.58 | 29-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.120194E+10 | 0.307407E+09 | 454.64 | 0.101352E+10 | 0.188424E+09 | 0.00 | 0.31 | 07-FEB-16:10 | 0.00 | 01-FEB-00:10 | 2292.49 | 07-FEB-16:20 | 2063.32 | 06-FEB-15:10 | 596.00 | 07-FEB-16:20 | 590.59 | 05-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.229515E+10 | 0.599923E+09 | 631.00 | 0.202800E+10 | 0.267152E+09 | 0.00 | 0.43 | 27-MAR-13:00 | 0.00 | 03-MAR-06:05 | 2766.20 | 27-MAR-13:00 | 2766.20 | 27-MAR-13:00 | 535.08 | 28-MAR-19:00 | 823.38 | 27-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.372353E+10 | 0.991821E+09 | 702.69 | 0.316600E+10 | 0.557530E+09 | 0.00 | 0.51 | 28-APR-15:10 | 0.00 | 01-APR-05:00 | 3653.43 | 28-APR-15:10 | 3235.31 | 28-APR-13:00 | 1086.45 | 30-APR-15:40 | 1032.88 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.607232E+10 | 0.169268E+10 | 744.00 | 0.505609E+10 | 0.101623E+10 | 0.00 | 0.71 | 21-MAY-13:00 | 0.08 | 01-MAY-06:00 | 4957.14 | 21-MAY-13:00 | 4457.04 | 21-MAY-13:00 | 1419.53 | 29-MAY-13:50 | 1437.68 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.738943E+10 | 0.205997E+10 | 720.00 | 0.555980E+10 | 0.182963E+10 | 0.00 | 0.68 | 09-JUN-14:20 | 0.15 | 07-JUN-05:00 | 4847.29 | 09-JUN-13:00 | 3945.04 | 09-JUN-16:17 | 1624.75 | 08-JUN-13:50 | 1456.62 | 09-JUN-13:30 | 0.00 | 01-JUN-00:10 |
| July | 0.883375E+10 | 0.250860E+10 | 744.00 | 0.643284E+10 | 0.240091E+10 | 0.00 | 0.73 | 14-JUL-14:00 | 0.16 | 03-JUL-06:00 | 5455.60 | 30-JUL-16:10 | 4016.94 | 21-JUL-16:30 | 1952.71 | 30-JUL-17:10 | 1567.82 | 14-JUL-14:00 | 0.00 | 01-JUL-00:10 |
| August | 0.903115E+10 | 0.256700E+10 | 744.00 | 0.645260E+10 | 0.257854E+10 | 0.00 | 0.76 | 10-AUG-16:10 | 0.23 | 15-AUG-07:00 | 5572.33 | 22-AUG-17:10 | 4010.67 | 16-AUG-12:00 | 2237.62 | 22-AUG-17:10 | 1646.41 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.722073E+10 | 0.198932E+10 | 720.00 | 0.514289E+10 | 0.207784E+10 | 0.00 | 0.62 | 09-SEP-16:02 | 0.14 | 30-SEP-05:00 | 4753.15 | 09-SEP-16:02 | 3516.23 | 04-SEP-16:17 | 1745.24 | 08-SEP-17:20 | 1300.98 | 08-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.536039E+10 | 0.144240E+10 | 744.00 | 0.409490E+10 | 0.126549E+10 | 0.00 | 0.53 | 07-OCT-16:10 | 0.05 | 21-OCT-07:00 | 3942.29 | 07-OCT-16:10 | 2914.66 | 09-OCT-15:10 | 1689.17 | 07-OCT-10:30 | 1083.51 | 07-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.315677E+10 | 0.824387E+09 | 692.32 | 0.253499E+10 | 0.621781E+09 | 0.00 | 0.44 | 01-NOV-14:10 | 0.00 | 22-NOV-02:20 | 3298.24 | 01-NOV-15:10 | 2284.22 | 01-NOV-14:10 | 1037.72 | 01-NOV-15:10 | 892.22 | 01-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.140255E+10 | 0.355037E+09 | 523.83 | 0.114024E+10 | 0.262315E+09 | 0.00 | 0.26 | 10-DEC-13:00 | 0.00 | 01-DEC-03:00 | 1873.37 | 05-DEC-16:10 | 1615.84 | 10-DEC-13:00 | 595.89 | 05-DEC-16:10 | 484.91 | 10-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.563780E+11 | 0.155135E+11 | 7820.90 | 0.432108E+11 | 0.131672E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.690273E+09 | 0.174906E+09 | 400.42 | 0.588910E+09 | 0.101363E+09 | 0.00 | 0.22 | 0.00 | 1555.81 | 1338.57 | 414.81 | 395.58 | 0.00 | |||||||
| Maximum of Months | 0.903115E+10 | 0.256700E+10 | 744.00 | 0.645260E+10 | 0.257854E+10 | 0.00 | 0.76 | 0.23 | 5572.33 | 4457.04 | 2237.62 | 1646.41 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.145187E+10 | 0.366174E+09 | 468.08 | 0.129054E+10 | 0.161335E+09 | 0.00 | 0.31 | 28-JAN-14:00 | 0.00 | 01-JAN-00:10 | 2248.90 | 29-JAN-15:10 | 2141.47 | 28-JAN-14:00 | 453.66 | 30-JAN-15:30 | 575.00 | 28-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.184068E+10 | 0.468098E+09 | 489.92 | 0.160039E+10 | 0.240297E+09 | 0.00 | 0.43 | 05-FEB-14:00 | 0.00 | 01-FEB-01:00 | 3096.61 | 05-FEB-14:00 | 2931.12 | 05-FEB-14:00 | 662.55 | 07-FEB-16:20 | 849.90 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.278664E+10 | 0.724878E+09 | 641.08 | 0.249172E+10 | 0.294918E+09 | 0.00 | 0.49 | 01-MAR-15:10 | 0.00 | 03-MAR-06:05 | 3289.53 | 01-MAR-15:10 | 3289.53 | 01-MAR-15:10 | 545.49 | 28-MAR-19:00 | 969.49 | 01-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.399343E+10 | 0.106290E+10 | 702.14 | 0.341723E+10 | 0.576201E+09 | 0.00 | 0.53 | 28-APR-12:30 | 0.00 | 01-APR-05:05 | 3880.45 | 30-APR-15:40 | 3453.70 | 28-APR-13:00 | 1148.15 | 30-APR-15:40 | 1080.59 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.607080E+10 | 0.169502E+10 | 744.00 | 0.505707E+10 | 0.101373E+10 | 0.00 | 0.70 | 21-MAY-13:00 | 0.07 | 01-MAY-06:00 | 5049.49 | 21-MAY-13:00 | 4525.03 | 21-MAY-13:00 | 1450.38 | 29-MAY-13:50 | 1465.58 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.726754E+10 | 0.203087E+10 | 720.00 | 0.544912E+10 | 0.181842E+10 | 0.00 | 0.66 | 09-JUN-14:20 | 0.14 | 07-JUN-05:00 | 4827.41 | 09-JUN-13:00 | 3868.75 | 09-JUN-16:03 | 1616.71 | 08-JUN-13:50 | 1453.67 | 09-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.881035E+10 | 0.250719E+10 | 744.00 | 0.641022E+10 | 0.240013E+10 | 0.00 | 0.73 | 30-JUL-16:10 | 0.16 | 03-JUL-06:00 | 5640.11 | 30-JUL-16:10 | 4087.82 | 30-JUL-14:00 | 1979.27 | 30-JUL-17:10 | 1580.45 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.919056E+10 | 0.261538E+10 | 744.00 | 0.660171E+10 | 0.258885E+10 | 0.00 | 0.75 | 10-AUG-16:10 | 0.22 | 15-AUG-07:10 | 5649.97 | 22-AUG-17:10 | 4203.19 | 16-AUG-12:00 | 2231.81 | 22-AUG-17:10 | 1676.63 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.770875E+10 | 0.212288E+10 | 720.00 | 0.558828E+10 | 0.212047E+10 | 0.00 | 0.66 | 09-SEP-16:02 | 0.14 | 30-SEP-05:00 | 5178.28 | 09-SEP-16:02 | 3934.32 | 04-SEP-14:00 | 1759.43 | 09-SEP-16:02 | 1411.38 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.616516E+10 | 0.165583E+10 | 744.00 | 0.483962E+10 | 0.132554E+10 | 0.00 | 0.61 | 07-OCT-13:30 | 0.06 | 21-OCT-07:00 | 4675.85 | 07-OCT-13:30 | 3704.34 | 09-OCT-14:10 | 1835.94 | 07-OCT-10:30 | 1281.60 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.407457E+10 | 0.105940E+10 | 702.17 | 0.337807E+10 | 0.696490E+09 | 0.00 | 0.55 | 01-NOV-14:10 | 0.00 | 22-NOV-03:00 | 4191.42 | 01-NOV-14:10 | 3161.60 | 05-NOV-13:30 | 1108.45 | 01-NOV-15:10 | 1125.55 | 01-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.224975E+10 | 0.566370E+09 | 564.39 | 0.190746E+10 | 0.342293E+09 | 0.00 | 0.37 | 04-DEC-13:20 | 0.00 | 01-DEC-03:40 | 2829.22 | 05-DEC-13:50 | 2540.47 | 03-DEC-13:20 | 750.32 | 24-DEC-12:50 | 718.85 | 04-DEC-13:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.616101E+11 | 0.168750E+11 | 7983.78 | 0.480314E+11 | 0.135787E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.145187E+10 | 0.366174E+09 | 468.08 | 0.129054E+10 | 0.161335E+09 | 0.00 | 0.31 | 0.00 | 2248.90 | 2141.47 | 453.66 | 575.00 | 0.00 | |||||||
| Maximum of Months | 0.919056E+10 | 0.261538E+10 | 744.00 | 0.660171E+10 | 0.258885E+10 | 0.00 | 0.75 | 0.22 | 5649.97 | 4525.03 | 2231.81 | 1676.63 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.145395E+10 | 0.366656E+09 | 467.83 | 0.129354E+10 | 0.160404E+09 | 0.00 | 0.31 | 28-JAN-14:00 | 0.00 | 01-JAN-00:10 | 2248.53 | 29-JAN-15:10 | 2149.21 | 28-JAN-14:00 | 452.85 | 30-JAN-15:30 | 576.89 | 28-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.184070E+10 | 0.468055E+09 | 490.42 | 0.160177E+10 | 0.238931E+09 | 0.00 | 0.43 | 05-FEB-14:00 | 0.00 | 01-FEB-01:00 | 3100.22 | 05-FEB-14:00 | 2936.47 | 05-FEB-14:00 | 660.09 | 07-FEB-16:20 | 850.67 | 05-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 0.278483E+10 | 0.724358E+09 | 641.25 | 0.249165E+10 | 0.293184E+09 | 0.00 | 0.49 | 01-MAR-15:10 | 0.00 | 03-MAR-06:05 | 3284.81 | 01-MAR-15:10 | 3284.81 | 01-MAR-15:10 | 544.38 | 28-MAR-19:00 | 968.03 | 01-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.399340E+10 | 0.106279E+10 | 702.10 | 0.341921E+10 | 0.574187E+09 | 0.00 | 0.53 | 28-APR-12:30 | 0.00 | 01-APR-05:05 | 3876.84 | 30-APR-15:40 | 3464.04 | 28-APR-13:00 | 1146.27 | 30-APR-15:40 | 1079.80 | 28-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.607042E+10 | 0.169472E+10 | 744.00 | 0.505932E+10 | 0.101109E+10 | 0.00 | 0.70 | 21-MAY-13:00 | 0.07 | 01-MAY-06:00 | 5055.62 | 21-MAY-13:00 | 4533.73 | 21-MAY-13:00 | 1449.56 | 29-MAY-13:50 | 1466.83 | 21-MAY-13:00 | 0.00 | 01-MAY-00:10 |
| June | 0.726539E+10 | 0.202999E+10 | 720.00 | 0.544976E+10 | 0.181564E+10 | 0.00 | 0.67 | 09-JUN-14:20 | 0.14 | 07-JUN-05:00 | 4832.92 | 09-JUN-13:00 | 3859.97 | 09-JUN-16:03 | 1614.77 | 08-JUN-13:50 | 1454.04 | 09-JUN-13:30 | 0.00 | 01-JUN-00:10 |
| July | 0.880798E+10 | 0.250612E+10 | 744.00 | 0.641084E+10 | 0.239714E+10 | 0.00 | 0.73 | 30-JUL-16:10 | 0.16 | 03-JUL-06:00 | 5633.99 | 30-JUL-16:10 | 4092.62 | 30-JUL-14:00 | 1977.28 | 30-JUL-17:10 | 1578.48 | 30-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.918826E+10 | 0.261429E+10 | 744.00 | 0.660245E+10 | 0.258581E+10 | 0.00 | 0.75 | 10-AUG-16:10 | 0.22 | 15-AUG-07:10 | 5638.41 | 22-AUG-17:10 | 4214.53 | 16-AUG-12:00 | 2228.91 | 22-AUG-17:10 | 1673.44 | 10-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.770662E+10 | 0.212197E+10 | 720.00 | 0.558899E+10 | 0.211763E+10 | 0.00 | 0.66 | 09-SEP-16:02 | 0.14 | 30-SEP-05:00 | 5167.41 | 09-SEP-16:02 | 3937.46 | 04-SEP-14:00 | 1756.28 | 09-SEP-16:02 | 1408.31 | 09-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 0.616404E+10 | 0.165527E+10 | 744.00 | 0.484090E+10 | 0.132314E+10 | 0.00 | 0.61 | 07-OCT-13:30 | 0.06 | 21-OCT-07:00 | 4678.51 | 07-OCT-13:30 | 3706.63 | 09-OCT-13:50 | 1836.97 | 07-OCT-10:30 | 1282.00 | 07-OCT-13:30 | 0.00 | 01-OCT-00:10 |
| November | 0.407333E+10 | 0.105893E+10 | 701.83 | 0.337897E+10 | 0.694360E+09 | 0.00 | 0.55 | 01-NOV-14:10 | 0.00 | 22-NOV-03:00 | 4190.78 | 01-NOV-14:10 | 3166.06 | 05-NOV-13:30 | 1106.02 | 01-NOV-15:10 | 1125.37 | 01-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.224918E+10 | 0.566163E+09 | 564.06 | 0.190842E+10 | 0.340761E+09 | 0.00 | 0.38 | 04-DEC-13:20 | 0.00 | 01-DEC-03:30 | 2830.62 | 05-DEC-13:50 | 2545.50 | 03-DEC-13:20 | 749.21 | 24-DEC-12:50 | 719.68 | 04-DEC-13:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.615981E+11 | 0.168693E+11 | 7983.49 | 0.480458E+11 | 0.135523E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.145395E+10 | 0.366656E+09 | 467.83 | 0.129354E+10 | 0.160404E+09 | 0.00 | 0.31 | 0.00 | 2248.53 | 2149.21 | 452.85 | 576.89 | 0.00 | |||||||
| Maximum of Months | 0.918826E+10 | 0.261429E+10 | 744.00 | 0.660245E+10 | 0.258581E+10 | 0.00 | 0.75 | 0.22 | 5638.41 | 4533.73 | 2228.91 | 1673.44 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 204.32 | 82.44 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 205.23 | 68.27 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 184.50 | 50.38 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 179.10 | 28.06 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 200.87 | 4.80 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 212.90 | 0.53 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 251.33 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 276.67 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 278.10 | 1.77 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 284.74 | 9.72 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 266.58 | 34.78 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.32 | 67.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 230.13 | 28.84 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 179.10 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 284.74 | 82.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 49.54 | 14.26 | 35.28 | 65.87 | 57.98 | 0.00 | 0.00 | 0.00 |
| February | 56.50 | 16.17 | 40.33 | 83.69 | 46.41 | 0.00 | 0.00 | 0.00 |
| March | 66.86 | 19.84 | 47.02 | 113.08 | 33.23 | 0.00 | 0.00 | 0.00 |
| April | 72.89 | 20.42 | 52.47 | 143.48 | 18.44 | 0.00 | 0.00 | 0.00 |
| May | 79.31 | 23.68 | 55.63 | 191.63 | 3.26 | 0.00 | 0.00 | 0.00 |
| June | 82.09 | 25.92 | 56.17 | 210.68 | 0.40 | 0.00 | 0.00 | 0.00 |
| July | 75.33 | 21.56 | 53.76 | 223.57 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.39 | 53.74 | 226.86 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 73.47 | 23.10 | 50.38 | 187.27 | 1.24 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 21.10 | 44.21 | 143.45 | 7.05 | 0.00 | 0.00 | 0.00 |
| November | 56.21 | 18.41 | 37.80 | 102.93 | 24.28 | 0.00 | 0.00 | 0.00 |
| December | 47.03 | 14.25 | 32.78 | 69.34 | 46.93 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.84 | 20.19 | 46.65 | 147.18 | 19.82 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.03 | 14.25 | 32.78 | 65.87 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.09 | 25.92 | 56.17 | 226.86 | 57.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 49.54 | 14.26 | 35.28 | 67.42 | 56.52 | 0.00 | 0.00 | 0.00 |
| February | 56.50 | 16.17 | 40.33 | 85.08 | 45.30 | 0.00 | 0.00 | 0.00 |
| March | 66.86 | 19.84 | 47.02 | 114.08 | 32.56 | 0.00 | 0.00 | 0.00 |
| April | 72.89 | 20.42 | 52.47 | 144.02 | 18.19 | 0.00 | 0.00 | 0.00 |
| May | 79.31 | 23.68 | 55.63 | 191.60 | 3.26 | 0.00 | 0.00 | 0.00 |
| June | 82.09 | 25.92 | 56.17 | 210.33 | 0.41 | 0.00 | 0.00 | 0.00 |
| July | 75.33 | 21.56 | 53.76 | 223.43 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.39 | 53.74 | 227.21 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 73.47 | 23.10 | 50.38 | 188.39 | 1.18 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 21.10 | 44.21 | 145.10 | 6.65 | 0.00 | 0.00 | 0.00 |
| November | 56.21 | 18.41 | 37.80 | 104.60 | 23.31 | 0.00 | 0.00 | 0.00 |
| December | 47.03 | 14.25 | 32.78 | 70.74 | 45.67 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.84 | 20.19 | 46.65 | 148.03 | 19.30 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.03 | 14.25 | 32.78 | 67.42 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.09 | 25.92 | 56.17 | 227.21 | 56.52 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 44.71 | 87.46 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 62.89 | 70.07 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 91.09 | 49.98 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 132.30 | 27.40 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 201.61 | 4.75 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 231.46 | 0.65 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 258.85 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 251.21 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 190.45 | 1.78 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 134.63 | 10.04 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 84.48 | 35.69 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 49.75 | 70.35 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 144.96 | 29.66 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 44.71 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 258.85 | 87.46 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 194.89 | 103.27 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 196.18 | 89.93 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 174.29 | 72.65 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 162.03 | 52.56 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 167.77 | 20.29 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 172.45 | 9.41 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 198.93 | 1.43 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 226.06 | 1.01 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 237.80 | 13.19 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 258.84 | 34.71 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 249.46 | 65.48 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 203.80 | 92.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 203.58 | 46.17 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 162.03 | 1.01 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 258.84 | 103.27 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.35 | 15.24 | 35.11 | 58.61 | 68.45 | 0.00 | 0.00 | 0.00 |
| February | 54.78 | 14.79 | 39.99 | 72.52 | 58.12 | 0.00 | 0.00 | 0.00 |
| March | 60.60 | 14.89 | 45.71 | 93.54 | 45.46 | 0.00 | 0.00 | 0.00 |
| April | 74.00 | 21.64 | 52.36 | 132.93 | 32.23 | 0.00 | 0.00 | 0.00 |
| May | 82.34 | 26.18 | 56.15 | 173.88 | 12.13 | 0.00 | 0.00 | 0.00 |
| June | 80.76 | 24.71 | 56.05 | 180.94 | 5.90 | 0.00 | 0.00 | 0.00 |
| July | 75.43 | 21.78 | 53.65 | 189.56 | 0.89 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.63 | 53.50 | 194.53 | 0.61 | 0.00 | 0.00 | 0.00 |
| September | 72.45 | 22.34 | 50.11 | 158.27 | 7.95 | 0.00 | 0.00 | 0.00 |
| October | 65.71 | 21.41 | 44.30 | 126.06 | 22.09 | 0.00 | 0.00 | 0.00 |
| November | 55.16 | 17.45 | 37.71 | 87.88 | 42.62 | 0.00 | 0.00 | 0.00 |
| December | 44.58 | 12.21 | 32.37 | 55.30 | 61.58 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.15 | 19.71 | 46.44 | 127.31 | 29.69 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44.58 | 12.21 | 32.37 | 55.30 | 0.61 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.34 | 26.18 | 56.15 | 194.53 | 68.45 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.35 | 15.24 | 35.11 | 65.51 | 52.80 | 0.00 | 0.00 | 0.00 |
| February | 54.78 | 14.79 | 39.99 | 79.74 | 42.80 | 0.00 | 0.00 | 0.00 |
| March | 60.60 | 14.89 | 45.71 | 101.65 | 30.59 | 0.00 | 0.00 | 0.00 |
| April | 74.00 | 21.64 | 52.36 | 145.63 | 16.90 | 0.00 | 0.00 | 0.00 |
| May | 82.34 | 26.18 | 56.15 | 196.42 | 2.87 | 0.00 | 0.00 | 0.00 |
| June | 80.76 | 24.71 | 56.05 | 207.14 | 0.34 | 0.00 | 0.00 | 0.00 |
| July | 75.43 | 21.78 | 53.65 | 223.91 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.63 | 53.50 | 228.24 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 72.45 | 22.34 | 50.11 | 186.80 | 0.99 | 0.00 | 0.00 | 0.00 |
| October | 65.71 | 21.41 | 44.30 | 145.36 | 5.76 | 0.00 | 0.00 | 0.00 |
| November | 55.16 | 17.45 | 37.71 | 100.75 | 21.61 | 0.00 | 0.00 | 0.00 |
| December | 44.58 | 12.21 | 32.37 | 63.59 | 43.10 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.15 | 19.71 | 46.44 | 145.77 | 18.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44.58 | 12.21 | 32.37 | 63.59 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.34 | 26.18 | 56.15 | 228.24 | 52.80 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 44.41 | 87.33 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 62.65 | 69.89 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 90.98 | 49.72 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 132.02 | 27.28 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 201.36 | 4.72 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 231.40 | 0.64 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 258.78 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 251.13 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 190.38 | 1.77 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 134.49 | 10.00 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 84.32 | 35.56 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 49.59 | 70.16 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 144.80 | 29.57 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 44.41 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 258.78 | 87.33 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 44.91 | 87.74 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.26 | 70.22 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 91.81 | 49.93 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 133.66 | 27.06 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 204.67 | 4.48 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 235.44 | 0.55 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 263.62 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 256.59 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 195.03 | 1.57 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 137.87 | 9.21 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 86.23 | 34.59 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 50.35 | 69.88 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 147.47 | 29.42 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 263.62 | 87.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 44.90 | 87.74 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.25 | 70.21 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 91.80 | 49.92 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 133.65 | 27.06 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 204.65 | 4.48 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 235.43 | 0.55 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 263.62 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 256.58 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 195.02 | 1.57 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 137.86 | 9.20 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 86.22 | 34.59 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 50.34 | 69.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 147.46 | 29.41 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 44.90 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 263.62 | 87.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 204.45 | 82.74 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 205.51 | 68.49 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 185.09 | 50.40 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 180.32 | 27.78 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 203.85 | 4.54 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 216.89 | 0.45 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 256.01 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 281.88 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 282.36 | 1.58 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 287.65 | 8.98 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 268.07 | 33.83 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.81 | 67.28 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 232.49 | 28.65 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 180.32 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 287.65 | 82.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 203.96 | 83.45 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 205.00 | 69.24 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 184.49 | 51.19 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 179.43 | 28.61 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 202.24 | 4.90 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 215.03 | 0.53 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 254.05 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 280.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 280.60 | 1.73 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 286.32 | 9.60 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 267.17 | 34.82 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.23 | 68.16 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 231.29 | 29.17 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 179.43 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 286.32 | 83.45 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 204.08 | 81.07 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 204.53 | 67.60 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 183.67 | 50.36 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 178.73 | 27.86 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 202.98 | 4.38 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 217.00 | 0.39 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 256.96 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 283.98 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 284.40 | 1.25 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 289.11 | 7.50 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 268.63 | 31.39 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.84 | 65.13 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 232.67 | 27.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 178.73 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 289.11 | 81.07 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 49.54 | 14.26 | 35.28 | 65.93 | 57.04 | 0.00 | 0.00 | 0.00 |
| February | 56.50 | 16.17 | 40.33 | 83.45 | 45.98 | 0.00 | 0.00 | 0.00 |
| March | 66.86 | 19.84 | 47.02 | 112.53 | 33.25 | 0.00 | 0.00 | 0.00 |
| April | 72.89 | 20.42 | 52.47 | 143.13 | 18.34 | 0.00 | 0.00 | 0.00 |
| May | 79.31 | 23.68 | 55.63 | 192.75 | 3.01 | 0.00 | 0.00 | 0.00 |
| June | 82.09 | 25.92 | 56.17 | 213.03 | 0.31 | 0.00 | 0.00 | 0.00 |
| July | 75.33 | 21.56 | 53.76 | 227.06 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.39 | 53.74 | 231.45 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 73.47 | 23.10 | 50.38 | 191.51 | 0.90 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 21.10 | 44.21 | 146.57 | 5.56 | 0.00 | 0.00 | 0.00 |
| November | 56.21 | 18.41 | 37.80 | 104.61 | 22.00 | 0.00 | 0.00 | 0.00 |
| December | 47.03 | 14.25 | 32.78 | 69.87 | 45.26 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.84 | 20.19 | 46.65 | 148.87 | 19.18 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.03 | 14.25 | 32.78 | 65.93 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.09 | 25.92 | 56.17 | 231.45 | 57.04 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 49.54 | 14.26 | 35.28 | 67.53 | 55.62 | 0.00 | 0.00 | 0.00 |
| February | 56.50 | 16.17 | 40.33 | 84.78 | 45.06 | 0.00 | 0.00 | 0.00 |
| March | 66.86 | 19.84 | 47.02 | 113.43 | 32.76 | 0.00 | 0.00 | 0.00 |
| April | 72.89 | 20.42 | 52.47 | 143.63 | 18.15 | 0.00 | 0.00 | 0.00 |
| May | 79.31 | 23.68 | 55.63 | 192.76 | 3.01 | 0.00 | 0.00 | 0.00 |
| June | 82.09 | 25.92 | 56.17 | 212.77 | 0.31 | 0.00 | 0.00 | 0.00 |
| July | 75.33 | 21.56 | 53.76 | 226.99 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.39 | 53.74 | 231.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 73.47 | 23.10 | 50.38 | 192.55 | 0.86 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 21.10 | 44.21 | 148.16 | 5.29 | 0.00 | 0.00 | 0.00 |
| November | 56.21 | 18.41 | 37.80 | 106.26 | 21.24 | 0.00 | 0.00 | 0.00 |
| December | 47.03 | 14.25 | 32.78 | 71.29 | 44.14 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.84 | 20.19 | 46.65 | 149.70 | 18.75 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.03 | 14.25 | 32.78 | 67.53 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.09 | 25.92 | 56.17 | 231.79 | 55.62 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 45.30 | 85.87 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 62.93 | 69.58 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 90.69 | 50.22 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 132.29 | 27.32 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 203.81 | 4.38 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 235.36 | 0.49 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 264.70 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 258.80 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 197.43 | 1.28 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 139.94 | 7.93 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 87.52 | 32.46 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 50.96 | 67.81 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 148.00 | 28.76 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 45.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 264.70 | 85.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 203.76 | 80.91 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 204.29 | 67.41 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 183.52 | 50.12 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 178.45 | 27.73 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 202.74 | 4.36 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 216.93 | 0.38 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 256.89 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 283.89 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 284.33 | 1.25 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 288.97 | 7.45 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 268.44 | 31.25 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.66 | 64.95 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 232.50 | 27.80 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 178.45 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 288.97 | 80.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.35 | 15.24 | 35.11 | 64.20 | 53.37 | 0.00 | 0.00 | 0.00 |
| February | 54.78 | 14.79 | 39.99 | 78.26 | 43.51 | 0.00 | 0.00 | 0.00 |
| March | 60.60 | 14.89 | 45.71 | 100.27 | 31.27 | 0.00 | 0.00 | 0.00 |
| April | 74.00 | 21.64 | 52.36 | 144.82 | 17.02 | 0.00 | 0.00 | 0.00 |
| May | 82.34 | 26.18 | 56.15 | 197.55 | 2.63 | 0.00 | 0.00 | 0.00 |
| June | 80.76 | 24.71 | 56.05 | 209.67 | 0.24 | 0.00 | 0.00 | 0.00 |
| July | 75.43 | 21.78 | 53.65 | 227.52 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.63 | 53.50 | 232.57 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 72.45 | 22.34 | 50.11 | 189.99 | 0.74 | 0.00 | 0.00 | 0.00 |
| October | 65.71 | 21.41 | 44.30 | 146.94 | 4.72 | 0.00 | 0.00 | 0.00 |
| November | 55.16 | 17.45 | 37.71 | 100.85 | 20.37 | 0.00 | 0.00 | 0.00 |
| December | 44.58 | 12.21 | 32.37 | 62.88 | 42.78 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.15 | 19.71 | 46.44 | 146.69 | 17.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44.58 | 12.21 | 32.37 | 62.88 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.34 | 26.18 | 56.15 | 232.57 | 53.37 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.35 | 15.24 | 35.11 | 65.74 | 51.98 | 0.00 | 0.00 | 0.00 |
| February | 54.78 | 14.79 | 39.99 | 79.55 | 42.57 | 0.00 | 0.00 | 0.00 |
| March | 60.60 | 14.89 | 45.71 | 101.15 | 30.77 | 0.00 | 0.00 | 0.00 |
| April | 74.00 | 21.64 | 52.36 | 145.31 | 16.83 | 0.00 | 0.00 | 0.00 |
| May | 82.34 | 26.18 | 56.15 | 197.56 | 2.62 | 0.00 | 0.00 | 0.00 |
| June | 80.76 | 24.71 | 56.05 | 209.42 | 0.24 | 0.00 | 0.00 | 0.00 |
| July | 75.43 | 21.78 | 53.65 | 227.45 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.63 | 53.50 | 232.90 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 72.45 | 22.34 | 50.11 | 191.02 | 0.70 | 0.00 | 0.00 | 0.00 |
| October | 65.71 | 21.41 | 44.30 | 148.55 | 4.47 | 0.00 | 0.00 | 0.00 |
| November | 55.16 | 17.45 | 37.71 | 102.50 | 19.64 | 0.00 | 0.00 | 0.00 |
| December | 44.58 | 12.21 | 32.37 | 64.29 | 41.66 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.15 | 19.71 | 46.44 | 147.51 | 17.51 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44.58 | 12.21 | 32.37 | 64.29 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.34 | 26.18 | 56.15 | 232.90 | 51.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 44.92 | 85.76 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 62.67 | 69.41 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 90.55 | 49.97 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 132.01 | 27.19 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 203.58 | 4.35 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 235.31 | 0.49 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 264.64 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 258.73 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 197.37 | 1.27 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 139.79 | 7.90 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 87.36 | 32.34 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 50.76 | 67.63 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 147.83 | 28.67 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 44.92 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 264.64 | 85.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 45.14 | 87.06 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.23 | 70.01 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 91.60 | 50.01 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 133.94 | 26.82 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 206.98 | 4.13 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 239.17 | 0.43 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 268.89 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 263.09 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 200.92 | 1.19 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 142.29 | 7.60 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 88.68 | 32.15 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 51.18 | 68.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 150.13 | 28.78 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 45.14 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 268.89 | 87.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 45.12 | 87.06 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.22 | 70.00 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 91.60 | 50.00 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 133.93 | 26.82 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 206.97 | 4.13 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 239.16 | 0.43 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 268.89 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 263.09 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 200.92 | 1.19 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 142.29 | 7.60 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 88.68 | 32.15 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 51.17 | 68.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 150.12 | 28.78 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 45.12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 268.89 | 87.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 203.93 | 81.85 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 204.80 | 67.94 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 184.49 | 50.18 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 180.29 | 27.37 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 206.14 | 4.14 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 220.86 | 0.33 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 261.12 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 288.19 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 287.69 | 1.17 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 291.25 | 7.21 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 269.59 | 31.12 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.98 | 65.44 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 234.72 | 27.88 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 180.29 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 291.25 | 81.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 203.92 | 81.85 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 204.79 | 67.94 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 184.49 | 50.17 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 180.28 | 27.37 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 206.13 | 4.14 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 220.86 | 0.33 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 261.12 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 288.18 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 287.68 | 1.17 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 291.25 | 7.21 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 269.58 | 31.11 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.97 | 65.44 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 234.71 | 27.88 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 180.28 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 291.25 | 81.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 205.45 | 73.61 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 203.81 | 62.24 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 181.27 | 47.25 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 174.63 | 26.50 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 197.02 | 4.06 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 210.60 | 0.33 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 249.35 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 276.32 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 278.12 | 1.12 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 284.01 | 6.79 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 265.27 | 29.68 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.41 | 60.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 228.60 | 25.84 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 174.63 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 284.01 | 73.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 49.54 | 14.26 | 35.28 | 65.79 | 51.10 | 0.00 | 0.00 | 0.00 |
| February | 56.50 | 16.17 | 40.33 | 82.52 | 42.00 | 0.00 | 0.00 | 0.00 |
| March | 66.86 | 19.84 | 47.02 | 110.66 | 31.04 | 0.00 | 0.00 | 0.00 |
| April | 72.89 | 20.42 | 52.47 | 140.19 | 17.43 | 0.00 | 0.00 | 0.00 |
| May | 79.31 | 23.68 | 55.63 | 188.57 | 2.80 | 0.00 | 0.00 | 0.00 |
| June | 82.09 | 25.92 | 56.17 | 208.58 | 0.28 | 0.00 | 0.00 | 0.00 |
| July | 75.33 | 21.56 | 53.76 | 221.83 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.39 | 53.74 | 226.13 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 73.47 | 23.10 | 50.38 | 187.17 | 0.81 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 21.10 | 44.21 | 143.11 | 5.09 | 0.00 | 0.00 | 0.00 |
| November | 56.21 | 18.41 | 37.80 | 102.22 | 20.67 | 0.00 | 0.00 | 0.00 |
| December | 47.03 | 14.25 | 32.78 | 68.94 | 41.63 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.84 | 20.19 | 46.65 | 145.84 | 17.62 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.03 | 14.25 | 32.78 | 65.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.09 | 25.92 | 56.17 | 226.13 | 51.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 49.54 | 14.26 | 35.28 | 68.72 | 49.20 | 0.00 | 0.00 | 0.00 |
| February | 56.50 | 16.17 | 40.33 | 84.75 | 40.90 | 0.00 | 0.00 | 0.00 |
| March | 66.86 | 19.84 | 47.02 | 112.02 | 30.53 | 0.00 | 0.00 | 0.00 |
| April | 72.89 | 20.42 | 52.47 | 140.89 | 17.28 | 0.00 | 0.00 | 0.00 |
| May | 79.31 | 23.68 | 55.63 | 188.58 | 2.80 | 0.00 | 0.00 | 0.00 |
| June | 82.09 | 25.92 | 56.17 | 208.26 | 0.28 | 0.00 | 0.00 | 0.00 |
| July | 75.33 | 21.56 | 53.76 | 221.75 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.39 | 53.74 | 226.56 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 73.47 | 23.10 | 50.38 | 188.50 | 0.79 | 0.00 | 0.00 | 0.00 |
| October | 65.31 | 21.10 | 44.21 | 145.25 | 4.91 | 0.00 | 0.00 | 0.00 |
| November | 56.21 | 18.41 | 37.80 | 104.64 | 20.01 | 0.00 | 0.00 | 0.00 |
| December | 47.03 | 14.25 | 32.78 | 71.41 | 40.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.84 | 20.19 | 46.65 | 147.14 | 17.14 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.03 | 14.25 | 32.78 | 68.72 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.09 | 25.92 | 56.17 | 226.56 | 49.20 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 47.41 | 76.33 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.24 | 63.46 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 88.99 | 47.00 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 128.58 | 26.09 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 197.82 | 4.12 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 228.74 | 0.45 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 257.06 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 251.25 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 191.63 | 1.17 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 135.79 | 7.36 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 85.37 | 30.66 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 51.45 | 62.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 144.45 | 26.38 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 47.41 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 257.06 | 76.33 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 204.57 | 73.27 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 203.19 | 61.87 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 180.90 | 46.86 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 174.16 | 26.28 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 196.69 | 4.02 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 210.48 | 0.33 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 249.23 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 276.18 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 277.99 | 1.11 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 283.80 | 6.75 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 264.92 | 29.45 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 214.91 | 60.21 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 228.25 | 25.68 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 174.16 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 283.80 | 73.27 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.35 | 15.24 | 35.11 | 65.27 | 48.71 | 0.00 | 0.00 | 0.00 |
| February | 54.78 | 14.79 | 39.99 | 78.13 | 40.28 | 0.00 | 0.00 | 0.00 |
| March | 60.60 | 14.89 | 45.71 | 98.95 | 29.44 | 0.00 | 0.00 | 0.00 |
| April | 74.00 | 21.64 | 52.36 | 142.13 | 16.21 | 0.00 | 0.00 | 0.00 |
| May | 82.34 | 26.18 | 56.15 | 193.44 | 2.43 | 0.00 | 0.00 | 0.00 |
| June | 80.76 | 24.71 | 56.05 | 205.22 | 0.21 | 0.00 | 0.00 | 0.00 |
| July | 75.43 | 21.78 | 53.65 | 222.34 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.63 | 53.50 | 227.34 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 72.45 | 22.34 | 50.11 | 185.74 | 0.65 | 0.00 | 0.00 | 0.00 |
| October | 65.71 | 21.41 | 44.30 | 143.56 | 4.25 | 0.00 | 0.00 | 0.00 |
| November | 55.16 | 17.45 | 37.71 | 98.72 | 19.24 | 0.00 | 0.00 | 0.00 |
| December | 44.58 | 12.21 | 32.37 | 62.72 | 39.84 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.15 | 19.71 | 46.44 | 144.01 | 16.66 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44.58 | 12.21 | 32.37 | 62.72 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.34 | 26.18 | 56.15 | 227.34 | 48.71 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.35 | 15.24 | 35.11 | 68.02 | 46.75 | 0.00 | 0.00 | 0.00 |
| February | 54.78 | 14.79 | 39.99 | 80.22 | 39.11 | 0.00 | 0.00 | 0.00 |
| March | 60.60 | 14.89 | 45.71 | 100.25 | 28.90 | 0.00 | 0.00 | 0.00 |
| April | 74.00 | 21.64 | 52.36 | 142.81 | 16.06 | 0.00 | 0.00 | 0.00 |
| May | 82.34 | 26.18 | 56.15 | 193.45 | 2.42 | 0.00 | 0.00 | 0.00 |
| June | 80.76 | 24.71 | 56.05 | 204.90 | 0.21 | 0.00 | 0.00 | 0.00 |
| July | 75.43 | 21.78 | 53.65 | 222.26 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 77.12 | 23.63 | 53.50 | 227.78 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 72.45 | 22.34 | 50.11 | 187.05 | 0.63 | 0.00 | 0.00 | 0.00 |
| October | 65.71 | 21.41 | 44.30 | 145.68 | 4.09 | 0.00 | 0.00 | 0.00 |
| November | 55.16 | 17.45 | 37.71 | 101.09 | 18.58 | 0.00 | 0.00 | 0.00 |
| December | 44.58 | 12.21 | 32.37 | 65.10 | 38.42 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.15 | 19.71 | 46.44 | 145.26 | 16.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44.58 | 12.21 | 32.37 | 65.10 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 82.34 | 26.18 | 56.15 | 227.78 | 46.75 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 46.38 | 75.97 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 62.52 | 63.06 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 88.61 | 46.59 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 128.12 | 25.87 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 197.50 | 4.08 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 228.64 | 0.44 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 256.96 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 251.13 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 191.53 | 1.16 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 135.59 | 7.32 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 85.05 | 30.47 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 50.87 | 61.67 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 144.08 | 26.22 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 46.38 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 256.96 | 75.97 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 47.04 | 78.99 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.46 | 65.25 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 90.15 | 47.55 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 130.79 | 25.95 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 201.76 | 3.97 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 233.33 | 0.41 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 262.13 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 256.43 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 195.87 | 1.12 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 138.83 | 7.21 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 86.97 | 30.76 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 51.56 | 63.68 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 147.04 | 26.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 47.04 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 262.13 | 78.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 42.30 | 0.00 | 42.30 | 46.97 | 78.97 | 0.00 | 0.00 | 0.00 |
| February | 48.48 | 0.00 | 48.48 | 63.41 | 65.23 | 0.00 | 0.00 | 0.00 |
| March | 55.70 | 0.00 | 55.70 | 90.13 | 47.53 | 0.00 | 0.00 | 0.00 |
| April | 62.85 | 0.18 | 62.67 | 130.76 | 25.94 | 0.00 | 0.00 | 0.00 |
| May | 70.80 | 2.24 | 68.57 | 201.74 | 3.97 | 0.00 | 0.00 | 0.00 |
| June | 75.48 | 4.09 | 71.39 | 233.32 | 0.41 | 0.00 | 0.00 | 0.00 |
| July | 69.38 | 1.98 | 67.41 | 262.12 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 64.78 | 0.70 | 64.08 | 256.43 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58.85 | 0.01 | 58.83 | 195.87 | 1.12 | 0.00 | 0.00 | 0.00 |
| October | 52.16 | 0.00 | 52.16 | 138.82 | 7.20 | 0.00 | 0.00 | 0.00 |
| November | 44.78 | 0.00 | 44.78 | 86.95 | 30.75 | 0.00 | 0.00 | 0.00 |
| December | 39.48 | 0.00 | 39.48 | 51.53 | 63.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 57.12 | 0.77 | 56.35 | 147.02 | 26.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.48 | 0.00 | 39.48 | 46.97 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 75.48 | 4.09 | 71.39 | 262.12 | 78.97 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 204.62 | 76.07 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 203.79 | 63.96 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 182.27 | 47.83 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 176.71 | 26.39 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 200.94 | 3.93 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 215.25 | 0.30 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 254.36 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 281.39 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 282.11 | 1.08 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 286.74 | 6.67 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 266.52 | 29.74 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.20 | 62.02 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 231.00 | 26.32 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 176.71 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 286.74 | 76.07 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 136.69 | 64.21 | 72.49 | 204.57 | 76.05 | 0.00 | 0.00 | 0.00 |
| February | 128.91 | 53.05 | 75.86 | 203.76 | 63.94 | 0.00 | 0.00 | 0.00 |
| March | 103.79 | 26.83 | 76.96 | 182.25 | 47.81 | 0.00 | 0.00 | 0.00 |
| April | 84.82 | 10.55 | 74.27 | 176.69 | 26.37 | 0.00 | 0.00 | 0.00 |
| May | 70.47 | 1.18 | 69.28 | 200.92 | 3.92 | 0.00 | 0.00 | 0.00 |
| June | 66.29 | 0.12 | 66.17 | 215.24 | 0.30 | 0.00 | 0.00 | 0.00 |
| July | 66.27 | 0.55 | 65.72 | 254.36 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76.77 | 5.34 | 71.43 | 281.38 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 102.39 | 24.27 | 78.12 | 282.10 | 1.08 | 0.00 | 0.00 | 0.00 |
| October | 132.13 | 52.22 | 79.91 | 286.73 | 6.67 | 0.00 | 0.00 | 0.00 |
| November | 146.94 | 71.12 | 75.82 | 266.51 | 29.73 | 0.00 | 0.00 | 0.00 |
| December | 135.47 | 66.76 | 68.72 | 215.17 | 62.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 104.09 | 31.22 | 72.86 | 230.98 | 26.32 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 66.27 | 0.12 | 65.72 | 176.69 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.94 | 71.12 | 79.91 | 286.73 | 76.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 12.08 | 3.66 | 8.42 | 15.20 | 13.56 | 242.00 | 0.00 | 0.00 |
| February | 13.14 | 3.55 | 9.60 | 18.01 | 11.58 | 204.17 | 0.00 | 0.00 |
| March | 14.54 | 3.57 | 10.97 | 22.62 | 8.81 | 201.17 | 0.00 | 0.00 |
| April | 17.76 | 5.19 | 12.56 | 32.38 | 5.41 | 217.00 | 0.00 | 0.00 |
| May | 19.76 | 6.28 | 13.47 | 43.17 | 1.18 | 110.50 | 0.00 | 0.00 |
| June | 19.38 | 5.93 | 13.45 | 45.37 | 0.24 | 30.83 | 0.00 | 0.00 |
| July | 18.10 | 5.23 | 12.87 | 48.99 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 18.51 | 5.67 | 12.84 | 50.20 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 17.38 | 5.36 | 12.02 | 41.01 | 0.39 | 45.00 | 0.00 | 0.00 |
| October | 15.77 | 5.14 | 10.63 | 32.14 | 1.92 | 169.83 | 0.00 | 0.00 |
| November | 13.24 | 4.19 | 9.05 | 22.54 | 6.19 | 225.00 | 0.00 | 0.00 |
| December | 10.70 | 2.93 | 7.77 | 14.44 | 11.45 | 289.67 | 0.00 | 0.00 |
| Annual Sum or Average | 15.87 | 4.73 | 11.14 | 32.25 | 5.03 | 1735.17 | 0.00 | 0.00 |
| Minimum of Months | 10.70 | 2.93 | 7.77 | 14.44 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 19.76 | 6.28 | 13.47 | 50.20 | 13.56 | 289.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 35.98 | 10.89 | 25.09 | 43.37 | 43.57 | 12.17 | 0.00 | 0.00 |
| February | 39.15 | 10.57 | 28.58 | 52.37 | 36.81 | 20.33 | 0.00 | 0.00 |
| March | 43.31 | 10.64 | 32.67 | 66.20 | 28.14 | 19.00 | 0.00 | 0.00 |
| April | 52.88 | 15.47 | 37.42 | 94.32 | 18.38 | 50.67 | 0.00 | 0.00 |
| May | 58.84 | 18.71 | 40.13 | 122.75 | 5.33 | 51.33 | 0.00 | 0.00 |
| June | 57.72 | 17.66 | 40.06 | 127.20 | 1.93 | 55.83 | 0.00 | 0.00 |
| July | 53.90 | 15.56 | 38.34 | 135.36 | 0.10 | 2.00 | 0.00 | 0.00 |
| August | 55.12 | 16.89 | 38.23 | 137.88 | 0.06 | 3.83 | 0.00 | 0.00 |
| September | 51.78 | 15.97 | 35.81 | 112.94 | 2.64 | 81.67 | 0.00 | 0.00 |
| October | 46.96 | 15.30 | 31.66 | 89.92 | 9.67 | 85.83 | 0.00 | 0.00 |
| November | 39.42 | 12.47 | 26.95 | 63.99 | 23.10 | 42.67 | 0.00 | 0.00 |
| December | 31.86 | 8.72 | 23.13 | 41.06 | 37.67 | 37.67 | 0.00 | 0.00 |
| Annual Sum or Average | 47.27 | 14.09 | 33.19 | 90.83 | 17.18 | 463.00 | 0.00 | 0.00 |
| Minimum of Months | 31.86 | 8.72 | 23.13 | 41.06 | 0.06 | 2.00 | 0.00 | 0.00 |
| Maximum of Months | 58.84 | 18.71 | 40.13 | 137.88 | 43.57 | 85.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 12.08 | 3.66 | 8.42 | 14.16 | 14.93 | 373.83 | 0.00 | 0.00 |
| February | 13.14 | 3.55 | 9.60 | 17.36 | 12.52 | 296.83 | 0.00 | 0.00 |
| March | 14.54 | 3.57 | 10.97 | 22.39 | 9.36 | 284.67 | 0.00 | 0.00 |
| April | 17.76 | 5.19 | 12.56 | 32.66 | 5.62 | 261.00 | 0.00 | 0.00 |
| May | 19.76 | 6.28 | 13.47 | 44.18 | 1.22 | 119.83 | 0.00 | 0.00 |
| June | 19.38 | 5.93 | 13.45 | 46.60 | 0.26 | 32.83 | 0.00 | 0.00 |
| July | 18.10 | 5.23 | 12.87 | 50.64 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 18.51 | 5.67 | 12.84 | 51.87 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 17.38 | 5.36 | 12.02 | 42.12 | 0.42 | 45.67 | 0.00 | 0.00 |
| October | 15.77 | 5.14 | 10.63 | 32.73 | 2.05 | 178.33 | 0.00 | 0.00 |
| November | 13.24 | 4.19 | 9.05 | 22.53 | 6.53 | 276.67 | 0.00 | 0.00 |
| December | 10.70 | 2.93 | 7.77 | 13.82 | 12.35 | 388.17 | 0.00 | 0.00 |
| Annual Sum or Average | 15.87 | 4.73 | 11.14 | 32.68 | 5.41 | 2257.83 | 0.00 | 0.00 |
| Minimum of Months | 10.70 | 2.93 | 7.77 | 13.82 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 19.76 | 6.28 | 13.47 | 51.87 | 14.93 | 388.17 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.547253E+09 | 0.220815E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.496490E+09 | 0.165163E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.494156E+09 | 0.134926E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.464219E+09 | 72718983.47 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.538009E+09 | 12849032.78 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.551849E+09 | 1374570.72 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.673173E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.741028E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.720829E+09 | 4595644.10 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.762650E+09 | 26036601.88 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.690981E+09 | 90143120.81 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.576717E+09 | 0.180926E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.725735E+10 | 0.909548E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.464219E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.762650E+09 | 0.220815E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.132696E+09 | 38193560.46 | 94502828.87 | 0.176431E+09 | 0.155302E+09 |
| February | 0.136675E+09 | 39106376.58 | 97568187.71 | 0.202471E+09 | 0.112284E+09 |
| March | 0.179077E+09 | 53150039.18 | 0.125927E+09 | 0.302878E+09 | 89004371.70 |
| April | 0.188929E+09 | 52925804.61 | 0.136003E+09 | 0.371899E+09 | 47785699.65 |
| May | 0.212417E+09 | 63420750.76 | 0.148996E+09 | 0.513253E+09 | 8741417.08 |
| June | 0.212783E+09 | 67197248.11 | 0.145586E+09 | 0.546084E+09 | 1029254.64 |
| July | 0.201752E+09 | 57759237.83 | 0.143993E+09 | 0.598810E+09 | 160.31 |
| August | 0.206565E+09 | 62636670.48 | 0.143928E+09 | 0.607626E+09 | 0.00 |
| September | 0.190446E+09 | 59872492.85 | 0.130574E+09 | 0.485410E+09 | 3214782.66 |
| October | 0.174918E+09 | 56505650.12 | 0.118412E+09 | 0.384204E+09 | 18885499.53 |
| November | 0.145694E+09 | 47707055.92 | 97987090.47 | 0.266795E+09 | 62938359.83 |
| December | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.185721E+09 | 0.125710E+09 |
| Annual Sum or Average | 0.210791E+10 | 0.636629E+09 | 0.147128E+10 | 0.464158E+10 | 0.624895E+09 |
| Minimum of Months | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.176431E+09 | 0.00 |
| Maximum of Months | 0.212783E+09 | 67197248.11 | 0.148996E+09 | 0.607626E+09 | 0.155302E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.132696E+09 | 38193560.46 | 94502828.87 | 0.180573E+09 | 0.151379E+09 |
| February | 0.136675E+09 | 39106376.58 | 97568187.71 | 0.205830E+09 | 0.109579E+09 |
| March | 0.179077E+09 | 53150039.18 | 0.125927E+09 | 0.305556E+09 | 87214807.90 |
| April | 0.188929E+09 | 52925804.61 | 0.136003E+09 | 0.373303E+09 | 47140533.46 |
| May | 0.212417E+09 | 63420750.76 | 0.148996E+09 | 0.513187E+09 | 8735939.48 |
| June | 0.212783E+09 | 67197248.11 | 0.145586E+09 | 0.545186E+09 | 1054689.70 |
| July | 0.201752E+09 | 57759237.83 | 0.143993E+09 | 0.598448E+09 | 170.21 |
| August | 0.206565E+09 | 62636670.48 | 0.143928E+09 | 0.608547E+09 | 0.00 |
| September | 0.190446E+09 | 59872492.85 | 0.130574E+09 | 0.488314E+09 | 3050470.58 |
| October | 0.174918E+09 | 56505650.12 | 0.118412E+09 | 0.388626E+09 | 17809557.37 |
| November | 0.145694E+09 | 47707055.92 | 97987090.47 | 0.271120E+09 | 60424743.24 |
| December | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.189466E+09 | 0.122331E+09 |
| Annual Sum or Average | 0.210791E+10 | 0.636629E+09 | 0.147128E+10 | 0.466816E+10 | 0.608720E+09 |
| Minimum of Months | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.180573E+09 | 0.00 |
| Maximum of Months | 0.212783E+09 | 67197248.11 | 0.148996E+09 | 0.608547E+09 | 0.151379E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.119757E+09 | 0.234256E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.152133E+09 | 0.169512E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.243983E+09 | 0.133869E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.342933E+09 | 71008058.20 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.539982E+09 | 12727445.26 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.599935E+09 | 1678951.85 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.693312E+09 | 450.14 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.672837E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.493645E+09 | 4616791.94 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.360595E+09 | 26900446.68 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.218970E+09 | 92504531.38 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.133256E+09 | 0.188414E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.457134E+10 | 0.935488E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.119757E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.693312E+09 | 0.234256E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.521982E+09 | 0.276609E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.474593E+09 | 0.217547E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.466816E+09 | 0.194587E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.419974E+09 | 0.136242E+09 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.449346E+09 | 54344296.91 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.446985E+09 | 24387691.02 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.532827E+09 | 3821643.62 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.605476E+09 | 2706295.52 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.616370E+09 | 34185012.30 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.693266E+09 | 92956805.14 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.646595E+09 | 0.169737E+09 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.545862E+09 | 0.249040E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.642009E+10 | 0.145616E+10 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.419974E+09 | 2706295.52 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.693266E+09 | 0.276609E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.134858E+09 | 40820540.90 | 94037220.12 | 0.156984E+09 | 0.183334E+09 |
| February | 0.132522E+09 | 35776585.37 | 96745480.31 | 0.175444E+09 | 0.140601E+09 |
| March | 0.162321E+09 | 39893576.46 | 0.122427E+09 | 0.250527E+09 | 0.121773E+09 |
| April | 0.191808E+09 | 56098634.93 | 0.135710E+09 | 0.344561E+09 | 83547011.41 |
| May | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.465721E+09 | 32489073.11 |
| June | 0.209343E+09 | 64048954.93 | 0.145294E+09 | 0.469001E+09 | 15284723.56 |
| July | 0.202021E+09 | 58324813.24 | 0.143697E+09 | 0.507707E+09 | 2379367.64 |
| August | 0.206571E+09 | 63288657.42 | 0.143282E+09 | 0.521042E+09 | 1634915.67 |
| September | 0.187789E+09 | 57907467.61 | 0.129881E+09 | 0.410239E+09 | 20610663.06 |
| October | 0.176007E+09 | 57352389.30 | 0.118655E+09 | 0.337652E+09 | 59169340.24 |
| November | 0.142978E+09 | 45236885.89 | 97740614.33 | 0.227785E+09 | 0.110479E+09 |
| December | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.148124E+09 | 0.164939E+09 |
| Annual Sum or Average | 0.208614E+10 | 0.621577E+09 | 0.146456E+10 | 0.401479E+10 | 0.936240E+09 |
| Minimum of Months | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.148124E+09 | 1634915.67 |
| Maximum of Months | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.521042E+09 | 0.183334E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.134858E+09 | 40820540.90 | 94037220.12 | 0.175454E+09 | 0.141429E+09 |
| February | 0.132522E+09 | 35776585.37 | 96745480.31 | 0.192905E+09 | 0.103542E+09 |
| March | 0.162321E+09 | 39893576.46 | 0.122427E+09 | 0.272264E+09 | 81937666.55 |
| April | 0.191808E+09 | 56098634.93 | 0.135710E+09 | 0.377481E+09 | 43800252.72 |
| May | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.526103E+09 | 7699743.57 |
| June | 0.209343E+09 | 64048954.93 | 0.145294E+09 | 0.536895E+09 | 887182.84 |
| July | 0.202021E+09 | 58324813.24 | 0.143697E+09 | 0.599715E+09 | 0.00 |
| August | 0.206571E+09 | 63288657.42 | 0.143282E+09 | 0.611314E+09 | 0.00 |
| September | 0.187789E+09 | 57907467.61 | 0.129881E+09 | 0.484176E+09 | 2566721.17 |
| October | 0.176007E+09 | 57352389.30 | 0.118655E+09 | 0.389333E+09 | 15430661.50 |
| November | 0.142978E+09 | 45236885.89 | 97740614.33 | 0.261133E+09 | 56018932.91 |
| December | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.170315E+09 | 0.115451E+09 |
| Annual Sum or Average | 0.208614E+10 | 0.621577E+09 | 0.146456E+10 | 0.459709E+10 | 0.568763E+09 |
| Minimum of Months | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.170315E+09 | 0.00 |
| Maximum of Months | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.611314E+09 | 0.141429E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.118948E+09 | 0.233901E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.151571E+09 | 0.169077E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.243675E+09 | 0.133158E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.342207E+09 | 70707723.47 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.539314E+09 | 12650368.63 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.599801E+09 | 1650134.82 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.693129E+09 | 346.28 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.672616E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.493477E+09 | 4587524.61 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.360215E+09 | 26790843.43 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.218563E+09 | 92183549.60 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.132809E+09 | 0.187903E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.456632E+10 | 0.932611E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.118948E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.693129E+09 | 0.233901E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.120291E+09 | 0.235001E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.153034E+09 | 0.169875E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.245894E+09 | 0.133733E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.346448E+09 | 70139889.21 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.548176E+09 | 12001066.70 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.610252E+09 | 1435146.64 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.706091E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.687244E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.505505E+09 | 4058141.42 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.369258E+09 | 24655419.22 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.223496E+09 | 89657659.55 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.134849E+09 | 0.187156E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.465054E+10 | 0.927713E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.120291E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.706091E+09 | 0.235001E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.120262E+09 | 0.234993E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.153013E+09 | 0.169864E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.245886E+09 | 0.133704E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.346420E+09 | 70133424.94 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.548146E+09 | 11999832.23 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.610246E+09 | 1434333.49 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.706082E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.687233E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.505497E+09 | 4057226.62 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.369241E+09 | 24652250.11 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.223480E+09 | 89647710.02 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.134834E+09 | 0.187139E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.465034E+10 | 0.927625E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.120262E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.706082E+09 | 0.234993E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.547603E+09 | 0.221603E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.497168E+09 | 0.165685E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.495745E+09 | 0.134979E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.467401E+09 | 72011251.09 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.545978E+09 | 12172415.81 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.562181E+09 | 1179043.76 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.685690E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.754982E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.731881E+09 | 4083125.58 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.770444E+09 | 24039582.67 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.694827E+09 | 87689700.37 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.578022E+09 | 0.180203E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.733192E+10 | 0.903646E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.467401E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.770444E+09 | 0.221603E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.546286E+09 | 0.223503E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.495927E+09 | 0.167501E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.494138E+09 | 0.137097E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.465077E+09 | 74168227.22 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.541679E+09 | 13136285.84 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.557357E+09 | 1366328.86 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.680441E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.749950E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.727315E+09 | 4483598.46 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.766866E+09 | 25708732.15 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.692513E+09 | 90252440.39 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.576475E+09 | 0.182564E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.729402E+10 | 0.919781E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.465077E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.766866E+09 | 0.223503E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.546595E+09 | 0.217132E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.494797E+09 | 0.163530E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.491930E+09 | 0.134888E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.463269E+09 | 72205697.72 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.543654E+09 | 11744736.87 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.562455E+09 | 1003805.96 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.688251E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.760621E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.737164E+09 | 3252542.61 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.774353E+09 | 20083064.10 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.696281E+09 | 81357313.87 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.578112E+09 | 0.174456E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.733748E+10 | 0.879653E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.463269E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.774353E+09 | 0.217132E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.132696E+09 | 38193560.46 | 94502828.87 | 0.176581E+09 | 0.152771E+09 |
| February | 0.136675E+09 | 39106376.58 | 97568187.71 | 0.201893E+09 | 0.111236E+09 |
| March | 0.179077E+09 | 53150039.18 | 0.125927E+09 | 0.301406E+09 | 89057602.78 |
| April | 0.188929E+09 | 52925804.61 | 0.136003E+09 | 0.371001E+09 | 47548806.59 |
| May | 0.212417E+09 | 63420750.76 | 0.148996E+09 | 0.516270E+09 | 8066913.20 |
| June | 0.212783E+09 | 67197248.11 | 0.145586E+09 | 0.552174E+09 | 793777.76 |
| July | 0.201752E+09 | 57759237.83 | 0.143993E+09 | 0.608154E+09 | 0.00 |
| August | 0.206565E+09 | 62636670.48 | 0.143928E+09 | 0.619918E+09 | 0.00 |
| September | 0.190446E+09 | 59872492.85 | 0.130574E+09 | 0.496404E+09 | 2330758.86 |
| October | 0.174918E+09 | 56505650.12 | 0.118412E+09 | 0.392560E+09 | 14894514.63 |
| November | 0.145694E+09 | 47707055.92 | 97987090.47 | 0.271139E+09 | 57028345.39 |
| December | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.187129E+09 | 0.121224E+09 |
| Annual Sum or Average | 0.210791E+10 | 0.636629E+09 | 0.147128E+10 | 0.469463E+10 | 0.604951E+09 |
| Minimum of Months | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.176581E+09 | 0.00 |
| Maximum of Months | 0.212783E+09 | 67197248.11 | 0.148996E+09 | 0.619918E+09 | 0.152771E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.132696E+09 | 38193560.46 | 94502828.87 | 0.180872E+09 | 0.148970E+09 |
| February | 0.136675E+09 | 39106376.58 | 97568187.71 | 0.205103E+09 | 0.109001E+09 |
| March | 0.179077E+09 | 53150039.18 | 0.125927E+09 | 0.303799E+09 | 87731490.88 |
| April | 0.188929E+09 | 52925804.61 | 0.136003E+09 | 0.372280E+09 | 47056635.66 |
| May | 0.212417E+09 | 63420750.76 | 0.148996E+09 | 0.516289E+09 | 8048720.79 |
| June | 0.212783E+09 | 67197248.11 | 0.145586E+09 | 0.551502E+09 | 803959.86 |
| July | 0.201752E+09 | 57759237.83 | 0.143993E+09 | 0.607966E+09 | 0.00 |
| August | 0.206565E+09 | 62636670.48 | 0.143928E+09 | 0.620826E+09 | 0.00 |
| September | 0.190446E+09 | 59872492.85 | 0.130574E+09 | 0.499102E+09 | 2224132.82 |
| October | 0.174918E+09 | 56505650.12 | 0.118412E+09 | 0.396839E+09 | 14162685.63 |
| November | 0.145694E+09 | 47707055.92 | 97987090.47 | 0.275418E+09 | 55066128.30 |
| December | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.190941E+09 | 0.118226E+09 |
| Annual Sum or Average | 0.210791E+10 | 0.636629E+09 | 0.147128E+10 | 0.472094E+10 | 0.591290E+09 |
| Minimum of Months | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.180872E+09 | 0.00 |
| Maximum of Months | 0.212783E+09 | 67197248.11 | 0.148996E+09 | 0.620826E+09 | 0.148970E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.121331E+09 | 0.229985E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.152246E+09 | 0.168337E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.242906E+09 | 0.134498E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.342891E+09 | 70813218.52 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.545874E+09 | 11733853.63 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.610053E+09 | 1278445.91 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.708981E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.693180E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.511749E+09 | 3326833.24 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.374806E+09 | 21251914.76 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.226855E+09 | 84130965.08 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.136499E+09 | 0.181622E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.466737E+10 | 0.906977E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.121331E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.708981E+09 | 0.229985E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.545754E+09 | 0.216715E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.494226E+09 | 0.163088E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.491553E+09 | 0.134250E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.462541E+09 | 71872643.19 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.543023E+09 | 11667506.07 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.562281E+09 | 985093.02 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.688042E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.760376E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.736985E+09 | 3229589.14 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.773972E+09 | 19965559.48 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.695799E+09 | 80990113.31 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.577620E+09 | 0.173955E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.733217E+10 | 0.876719E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.462541E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.773972E+09 | 0.216715E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.134858E+09 | 40820540.90 | 94037220.12 | 0.171955E+09 | 0.142936E+09 |
| February | 0.132522E+09 | 35776585.37 | 96745480.31 | 0.189337E+09 | 0.105252E+09 |
| March | 0.162321E+09 | 39893576.46 | 0.122427E+09 | 0.268563E+09 | 83750536.64 |
| April | 0.191808E+09 | 56098634.93 | 0.135710E+09 | 0.375383E+09 | 44113874.40 |
| May | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.529124E+09 | 7033634.75 |
| June | 0.209343E+09 | 64048954.93 | 0.145294E+09 | 0.543469E+09 | 625700.78 |
| July | 0.202021E+09 | 58324813.24 | 0.143697E+09 | 0.609386E+09 | 0.00 |
| August | 0.206571E+09 | 63288657.42 | 0.143282E+09 | 0.622903E+09 | 0.00 |
| September | 0.187789E+09 | 57907467.61 | 0.129881E+09 | 0.492442E+09 | 1905602.90 |
| October | 0.176007E+09 | 57352389.30 | 0.118655E+09 | 0.393572E+09 | 12635987.24 |
| November | 0.142978E+09 | 45236885.89 | 97740614.33 | 0.261405E+09 | 52806961.97 |
| December | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.168424E+09 | 0.114576E+09 |
| Annual Sum or Average | 0.208614E+10 | 0.621577E+09 | 0.146456E+10 | 0.462596E+10 | 0.565636E+09 |
| Minimum of Months | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.168424E+09 | 0.00 |
| Maximum of Months | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.622903E+09 | 0.142936E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.134858E+09 | 40820540.90 | 94037220.12 | 0.176088E+09 | 0.139237E+09 |
| February | 0.132522E+09 | 35776585.37 | 96745480.31 | 0.192437E+09 | 0.102989E+09 |
| March | 0.162321E+09 | 39893576.46 | 0.122427E+09 | 0.270907E+09 | 82407295.63 |
| April | 0.191808E+09 | 56098634.93 | 0.135710E+09 | 0.376640E+09 | 43626352.65 |
| May | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.529147E+09 | 7012671.82 |
| June | 0.209343E+09 | 64048954.93 | 0.145294E+09 | 0.542814E+09 | 634709.81 |
| July | 0.202021E+09 | 58324813.24 | 0.143697E+09 | 0.609201E+09 | 0.00 |
| August | 0.206571E+09 | 63288657.42 | 0.143282E+09 | 0.623809E+09 | 0.00 |
| September | 0.187789E+09 | 57907467.61 | 0.129881E+09 | 0.495131E+09 | 1813769.01 |
| October | 0.176007E+09 | 57352389.30 | 0.118655E+09 | 0.397884E+09 | 11975294.51 |
| November | 0.142978E+09 | 45236885.89 | 97740614.33 | 0.265683E+09 | 50898855.38 |
| December | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.172187E+09 | 0.111575E+09 |
| Annual Sum or Average | 0.208614E+10 | 0.621577E+09 | 0.146456E+10 | 0.465193E+10 | 0.552170E+09 |
| Minimum of Months | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.172187E+09 | 0.00 |
| Maximum of Months | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.623809E+09 | 0.139237E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.120320E+09 | 0.229708E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.151607E+09 | 0.167908E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.242535E+09 | 0.133842E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.342166E+09 | 70480267.16 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.545261E+09 | 11645475.60 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.609917E+09 | 1257221.73 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.708802E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.692969E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.511575E+09 | 3302326.37 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.374423E+09 | 21147972.48 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.226436E+09 | 83826594.40 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.135963E+09 | 0.181148E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.466197E+10 | 0.904266E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.120320E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.708802E+09 | 0.229708E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.120897E+09 | 0.233178E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.152976E+09 | 0.169363E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.245342E+09 | 0.133938E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.347172E+09 | 69515483.10 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.554385E+09 | 11051794.21 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.619916E+09 | 1118986.45 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.720194E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.704670E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.520784E+09 | 3074768.11 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.381122E+09 | 20357558.05 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.229866E+09 | 83344941.69 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.137075E+09 | 0.182645E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.473440E+10 | 0.907589E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.120897E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.720194E+09 | 0.233178E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.120858E+09 | 0.233173E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.152952E+09 | 0.169351E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.245329E+09 | 0.133914E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.347146E+09 | 69506068.13 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.554361E+09 | 11049265.09 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.619909E+09 | 1118175.82 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.720187E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.704660E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.520776E+09 | 3073773.38 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.381105E+09 | 20353421.09 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.229848E+09 | 83334000.18 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.137055E+09 | 0.182629E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.473419E+10 | 0.907502E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.120858E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.720187E+09 | 0.233173E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.546212E+09 | 0.219234E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.495444E+09 | 0.164367E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.494137E+09 | 0.134409E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.467316E+09 | 70951532.49 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.552135E+09 | 11082452.10 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.572478E+09 | 859702.93 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.699396E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.771881E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.745684E+09 | 3029649.10 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.780087E+09 | 19310231.87 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.698773E+09 | 80656667.32 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.578480E+09 | 0.175286E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.740202E+10 | 0.879186E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.467316E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.780087E+09 | 0.219234E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.546186E+09 | 0.219224E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.495425E+09 | 0.164354E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.494125E+09 | 0.134386E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.467291E+09 | 70941822.59 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.552110E+09 | 11079931.10 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.572471E+09 | 858997.38 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.699388E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.771872E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.745677E+09 | 3028721.60 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.780073E+09 | 19306135.07 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.698758E+09 | 80645402.56 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.578465E+09 | 0.175271E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.740184E+10 | 0.879095E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.467291E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.780073E+09 | 0.219224E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.550268E+09 | 0.197166E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.493053E+09 | 0.150583E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.485521E+09 | 0.126560E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.452644E+09 | 68691062.62 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.527706E+09 | 10861047.99 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.545884E+09 | 868232.63 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.667868E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.740106E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.720878E+09 | 2896596.19 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.760694E+09 | 18199611.64 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.687584E+09 | 76930896.90 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.576950E+09 | 0.162183E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.720916E+10 | 0.814939E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.452644E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.760694E+09 | 0.197166E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.132696E+09 | 38193560.46 | 94502828.87 | 0.176204E+09 | 0.136866E+09 |
| February | 0.136675E+09 | 39106376.58 | 97568187.71 | 0.199633E+09 | 0.101606E+09 |
| March | 0.179077E+09 | 53150039.18 | 0.125927E+09 | 0.296379E+09 | 83126879.68 |
| April | 0.188929E+09 | 52925804.61 | 0.136003E+09 | 0.363366E+09 | 45182397.95 |
| May | 0.212417E+09 | 63420750.76 | 0.148996E+09 | 0.505078E+09 | 7509720.52 |
| June | 0.212783E+09 | 67197248.11 | 0.145586E+09 | 0.540641E+09 | 713840.07 |
| July | 0.201752E+09 | 57759237.83 | 0.143993E+09 | 0.594152E+09 | 0.00 |
| August | 0.206565E+09 | 62636670.48 | 0.143928E+09 | 0.605657E+09 | 0.00 |
| September | 0.190446E+09 | 59872492.85 | 0.130574E+09 | 0.485156E+09 | 2097256.64 |
| October | 0.174918E+09 | 56505650.12 | 0.118412E+09 | 0.383296E+09 | 13630888.45 |
| November | 0.145694E+09 | 47707055.92 | 97987090.47 | 0.264948E+09 | 53587344.79 |
| December | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.184651E+09 | 0.111494E+09 |
| Annual Sum or Average | 0.210791E+10 | 0.636629E+09 | 0.147128E+10 | 0.459916E+10 | 0.555814E+09 |
| Minimum of Months | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.176204E+09 | 0.00 |
| Maximum of Months | 0.212783E+09 | 67197248.11 | 0.148996E+09 | 0.605657E+09 | 0.136866E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.132696E+09 | 38193560.46 | 94502828.87 | 0.184073E+09 | 0.131786E+09 |
| February | 0.136675E+09 | 39106376.58 | 97568187.71 | 0.205021E+09 | 98943057.74 |
| March | 0.179077E+09 | 53150039.18 | 0.125927E+09 | 0.300047E+09 | 81765906.66 |
| April | 0.188929E+09 | 52925804.61 | 0.136003E+09 | 0.365190E+09 | 44789694.75 |
| May | 0.212417E+09 | 63420750.76 | 0.148996E+09 | 0.505092E+09 | 7497391.36 |
| June | 0.212783E+09 | 67197248.11 | 0.145586E+09 | 0.539802E+09 | 714332.51 |
| July | 0.201752E+09 | 57759237.83 | 0.143993E+09 | 0.593944E+09 | 0.00 |
| August | 0.206565E+09 | 62636670.48 | 0.143928E+09 | 0.606831E+09 | 0.00 |
| September | 0.190446E+09 | 59872492.85 | 0.130574E+09 | 0.488580E+09 | 2036393.24 |
| October | 0.174918E+09 | 56505650.12 | 0.118412E+09 | 0.389029E+09 | 13158011.98 |
| November | 0.145694E+09 | 47707055.92 | 97987090.47 | 0.271236E+09 | 51877544.37 |
| December | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.191274E+09 | 0.107810E+09 |
| Annual Sum or Average | 0.210791E+10 | 0.636629E+09 | 0.147128E+10 | 0.464012E+10 | 0.540378E+09 |
| Minimum of Months | 0.125960E+09 | 38154565.76 | 87805776.70 | 0.184073E+09 | 0.00 |
| Maximum of Months | 0.212783E+09 | 67197248.11 | 0.148996E+09 | 0.606831E+09 | 0.131786E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.126974E+09 | 0.204447E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.152990E+09 | 0.153513E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.238343E+09 | 0.125894E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.333271E+09 | 67633599.42 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.529836E+09 | 11028377.13 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.592891E+09 | 1162365.29 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.688520E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.672942E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.496714E+09 | 3036671.00 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.363706E+09 | 19701208.20 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.221272E+09 | 79459378.20 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.137809E+09 | 0.166136E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.455527E+10 | 0.832012E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.126974E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.688520E+09 | 0.204447E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.547915E+09 | 0.196237E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.491553E+09 | 0.149679E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.484515E+09 | 0.125503E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.451427E+09 | 68127042.82 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.526805E+09 | 10765997.31 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.545553E+09 | 849600.22 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.667529E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.739715E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.720559E+09 | 2877561.96 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.760120E+09 | 18069835.00 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.686668E+09 | 76327309.25 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.575607E+09 | 0.161257E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.719797E+10 | 0.809693E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.451427E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.760120E+09 | 0.196237E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.134858E+09 | 40820540.90 | 94037220.12 | 0.174810E+09 | 0.130477E+09 |
| February | 0.132522E+09 | 35776585.37 | 96745480.31 | 0.189017E+09 | 97438432.98 |
| March | 0.162321E+09 | 39893576.46 | 0.122427E+09 | 0.265022E+09 | 78851359.28 |
| April | 0.191808E+09 | 56098634.93 | 0.135710E+09 | 0.368394E+09 | 42025159.16 |
| May | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.518120E+09 | 6510340.04 |
| June | 0.209343E+09 | 64048954.93 | 0.145294E+09 | 0.531920E+09 | 545594.16 |
| July | 0.202021E+09 | 58324813.24 | 0.143697E+09 | 0.595503E+09 | 0.00 |
| August | 0.206571E+09 | 63288657.42 | 0.143282E+09 | 0.608910E+09 | 0.00 |
| September | 0.187789E+09 | 57907467.61 | 0.129881E+09 | 0.481447E+09 | 1685218.28 |
| October | 0.176007E+09 | 57352389.30 | 0.118655E+09 | 0.384502E+09 | 11379619.86 |
| November | 0.142978E+09 | 45236885.89 | 97740614.33 | 0.255883E+09 | 49867917.81 |
| December | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.167998E+09 | 0.106705E+09 |
| Annual Sum or Average | 0.208614E+10 | 0.621577E+09 | 0.146456E+10 | 0.454153E+10 | 0.525485E+09 |
| Minimum of Months | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.167998E+09 | 0.00 |
| Maximum of Months | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.608910E+09 | 0.130477E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.134858E+09 | 40820540.90 | 94037220.12 | 0.182184E+09 | 0.125207E+09 |
| February | 0.132522E+09 | 35776585.37 | 96745480.31 | 0.194071E+09 | 94624106.88 |
| March | 0.162321E+09 | 39893576.46 | 0.122427E+09 | 0.268515E+09 | 77406478.82 |
| April | 0.191808E+09 | 56098634.93 | 0.135710E+09 | 0.370158E+09 | 41622946.17 |
| May | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.518144E+09 | 6493792.23 |
| June | 0.209343E+09 | 64048954.93 | 0.145294E+09 | 0.531113E+09 | 545937.46 |
| July | 0.202021E+09 | 58324813.24 | 0.143697E+09 | 0.595301E+09 | 0.00 |
| August | 0.206571E+09 | 63288657.42 | 0.143282E+09 | 0.610075E+09 | 0.00 |
| September | 0.187789E+09 | 57907467.61 | 0.129881E+09 | 0.484827E+09 | 1636877.09 |
| October | 0.176007E+09 | 57352389.30 | 0.118655E+09 | 0.390201E+09 | 10959563.81 |
| November | 0.142978E+09 | 45236885.89 | 97740614.33 | 0.262019E+09 | 48165335.55 |
| December | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.174352E+09 | 0.102891E+09 |
| Annual Sum or Average | 0.208614E+10 | 0.621577E+09 | 0.146456E+10 | 0.458096E+10 | 0.509552E+09 |
| Minimum of Months | 0.119393E+09 | 32698437.17 | 86694076.79 | 0.174352E+09 | 0.00 |
| Maximum of Months | 0.220529E+09 | 70130223.31 | 0.150399E+09 | 0.610075E+09 | 0.125207E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.124215E+09 | 0.203479E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.151258E+09 | 0.152551E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.237321E+09 | 0.124797E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.332080E+09 | 67063954.69 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.528988E+09 | 10915551.65 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.592645E+09 | 1140408.57 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.688249E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.672636E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.496437E+09 | 3016183.23 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.363167E+09 | 19593632.00 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.220460E+09 | 78977770.57 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.136247E+09 | 0.165188E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.454370E+10 | 0.826723E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.124215E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.688249E+09 | 0.203479E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.125986E+09 | 0.211579E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.153518E+09 | 0.157849E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.241469E+09 | 0.127363E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.338996E+09 | 67274900.97 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.540381E+09 | 10640415.60 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.604782E+09 | 1064922.41 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.702077E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.686827E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.507706E+09 | 2905204.62 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.371835E+09 | 19298718.84 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.225420E+09 | 79730165.91 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.138108E+09 | 0.170548E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.463711E+10 | 0.848253E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.125986E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.702077E+09 | 0.211579E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.125804E+09 | 0.211524E+09 |
| February | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.153409E+09 | 0.157793E+09 |
| March | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.241408E+09 | 0.127295E+09 |
| April | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.338936E+09 | 67242543.95 |
| May | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.540342E+09 | 10633239.05 |
| June | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.604771E+09 | 1063484.22 |
| July | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.702066E+09 | 0.00 |
| August | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.686814E+09 | 0.00 |
| September | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.507692E+09 | 2903375.13 |
| October | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.371804E+09 | 19288945.10 |
| November | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.225369E+09 | 79698554.06 |
| December | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.138008E+09 | 0.170490E+09 |
| Annual Sum or Average | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.463642E+10 | 0.847932E+09 |
| Minimum of Months | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.125804E+09 | 0.00 |
| Maximum of Months | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.702066E+09 | 0.211524E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.548042E+09 | 0.203756E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.493014E+09 | 0.154741E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.488193E+09 | 0.128106E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.458025E+09 | 68390491.43 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.538188E+09 | 10518630.33 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.557918E+09 | 787030.02 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.681285E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.753664E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.731223E+09 | 2790559.89 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.768015E+09 | 17874367.26 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.690831E+09 | 77093266.68 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.576381E+09 | 0.166126E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.728478E+10 | 0.830182E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.458025E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.768015E+09 | 0.203756E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.547921E+09 | 0.203702E+09 |
| February | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.492938E+09 | 0.154688E+09 |
| March | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.488140E+09 | 0.128043E+09 |
| April | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.457968E+09 | 68357913.35 |
| May | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.538148E+09 | 10511731.83 |
| June | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.557905E+09 | 785778.92 |
| July | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.681272E+09 | 0.00 |
| August | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.753650E+09 | 0.00 |
| September | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.731211E+09 | 2789005.96 |
| October | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.767988E+09 | 17865238.74 |
| November | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.690789E+09 | 77061657.61 |
| December | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.576316E+09 | 0.166074E+09 |
| Annual Sum or Average | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.728424E+10 | 0.829878E+09 |
| Minimum of Months | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.457968E+09 | 0.00 |
| Maximum of Months | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.767988E+09 | 0.203702E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 32359668.68 | 9795054.94 | 22564613.74 | 40717049.59 | 36311584.02 |
| February | 31799209.08 | 8584737.28 | 23214471.79 | 43558030.57 | 28004683.86 |
| March | 38949495.85 | 9572626.05 | 29376869.79 | 60573276.68 | 23600511.18 |
| April | 46025197.84 | 13461095.80 | 32564102.05 | 83928430.55 | 14025358.50 |
| May | 52916859.73 | 16828032.54 | 36088827.19 | 0.115630E+09 | 3156452.78 |
| June | 50232589.73 | 15368807.44 | 34863782.29 | 0.117596E+09 | 625990.51 |
| July | 48475879.46 | 13995276.34 | 34480603.12 | 0.131204E+09 | 3780.19 |
| August | 49567553.04 | 15186370.96 | 34381182.08 | 0.134459E+09 | 0.00 |
| September | 45060655.36 | 13895132.56 | 31165522.80 | 0.106299E+09 | 1002462.47 |
| October | 42233706.50 | 13761939.26 | 28471767.24 | 86088116.67 | 5149147.66 |
| November | 34308033.15 | 10854774.90 | 23453258.25 | 58425995.73 | 16036038.42 |
| December | 28648719.70 | 7846123.10 | 20802596.60 | 38666191.62 | 30657257.28 |
| Annual Sum or Average | 0.500578E+09 | 0.149150E+09 | 0.351428E+09 | 0.101715E+10 | 0.158573E+09 |
| Minimum of Months | 28648719.70 | 7846123.10 | 20802596.60 | 38666191.62 | 0.00 |
| Maximum of Months | 52916859.73 | 16828032.54 | 36088827.19 | 0.134459E+09 | 36311584.02 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 96375146.46 | 29172111.25 | 67203035.21 | 0.116169E+09 | 0.116705E+09 |
| February | 94705958.29 | 25567484.06 | 69138474.23 | 0.126700E+09 | 89041892.69 |
| March | 0.116001E+09 | 28509662.66 | 87491629.07 | 0.177320E+09 | 75369069.86 |
| April | 0.137074E+09 | 40090493.25 | 96983999.91 | 0.244485E+09 | 47644083.70 |
| May | 0.157600E+09 | 50118068.79 | 0.107482E+09 | 0.328776E+09 | 14271266.68 |
| June | 0.149605E+09 | 45772133.29 | 0.103833E+09 | 0.329715E+09 | 4991888.85 |
| July | 0.144373E+09 | 41681415.86 | 0.102692E+09 | 0.362560E+09 | 276412.70 |
| August | 0.147625E+09 | 45228792.04 | 0.102396E+09 | 0.369289E+09 | 149722.58 |
| September | 0.134202E+09 | 41383162.75 | 92818682.85 | 0.292751E+09 | 6835786.69 |
| October | 0.125782E+09 | 40986479.96 | 84796008.42 | 0.240851E+09 | 25888682.20 |
| November | 0.102178E+09 | 32328221.01 | 69849639.73 | 0.165851E+09 | 59867838.48 |
| December | 85323016.88 | 23367707.19 | 61955309.69 | 0.109964E+09 | 0.100891E+09 |
| Annual Sum or Average | 0.149084E+10 | 0.444206E+09 | 0.104664E+10 | 0.286443E+10 | 0.541933E+09 |
| Minimum of Months | 85323016.88 | 23367707.19 | 61955309.69 | 0.109964E+09 | 149722.58 |
| Maximum of Months | 0.157600E+09 | 50118068.79 | 0.107482E+09 | 0.369289E+09 | 0.116705E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 32359668.68 | 9795054.94 | 22564613.74 | 37915250.89 | 40000530.83 |
| February | 31799209.08 | 8584737.28 | 23214471.79 | 41998049.68 | 30280770.27 |
| March | 38949495.85 | 9572626.05 | 29376869.79 | 59975856.27 | 25081654.22 |
| April | 46025197.84 | 13461095.80 | 32564102.05 | 84642120.37 | 14559253.49 |
| May | 52916859.73 | 16828032.54 | 36088827.19 | 0.118342E+09 | 3278708.57 |
| June | 50232589.73 | 15368807.44 | 34863782.29 | 0.120778E+09 | 665647.72 |
| July | 48475879.46 | 13995276.34 | 34480603.12 | 0.135626E+09 | 5054.67 |
| August | 49567553.04 | 15186370.96 | 34381182.08 | 0.138922E+09 | 0.00 |
| September | 45060655.36 | 13895132.56 | 31165522.80 | 0.109184E+09 | 1082453.50 |
| October | 42233706.50 | 13761939.26 | 28471767.24 | 87668392.40 | 5503646.48 |
| November | 34308033.15 | 10854774.90 | 23453258.25 | 58400324.69 | 16934679.60 |
| December | 28648719.70 | 7846123.10 | 20802596.60 | 37018589.29 | 33085120.34 |
| Annual Sum or Average | 0.500578E+09 | 0.149150E+09 | 0.351428E+09 | 0.103047E+10 | 0.170478E+09 |
| Minimum of Months | 28648719.70 | 7846123.10 | 20802596.60 | 37018589.29 | 0.00 |
| Maximum of Months | 52916859.73 | 16828032.54 | 36088827.19 | 0.138922E+09 | 40000530.83 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 268.14 | 138.38 | 186.23 | 78.47 | 107.77 | 0.00 | 0.00 |
| February | 288.05 | 113.81 | 185.40 | 69.21 | 116.19 | 0.00 | 0.00 |
| March | 297.24 | 83.26 | 170.65 | 46.67 | 123.97 | 0.00 | 0.00 |
| April | 322.54 | 46.45 | 157.70 | 30.96 | 126.74 | 0.00 | 0.00 |
| May | 392.49 | 8.06 | 149.78 | 24.86 | 124.91 | 0.00 | 0.00 |
| June | 423.58 | 0.92 | 148.38 | 26.04 | 122.34 | 0.00 | 0.00 |
| July | 474.90 | 0.00 | 141.60 | 22.11 | 119.49 | 0.00 | 0.00 |
| August | 503.53 | 0.00 | 153.89 | 28.73 | 125.16 | 0.00 | 0.00 |
| September | 465.37 | 3.01 | 175.87 | 47.37 | 128.50 | 0.00 | 0.00 |
| October | 428.02 | 16.60 | 197.44 | 73.32 | 124.12 | 0.00 | 0.00 |
| November | 368.67 | 58.21 | 203.15 | 89.52 | 113.62 | 0.00 | 0.00 |
| December | 283.08 | 112.91 | 182.50 | 81.00 | 101.50 | 0.00 | 0.00 |
| Annual Sum or Average | 376.82 | 48.16 | 170.93 | 51.41 | 119.52 | 0.00 | 0.00 |
| Minimum of Months | 268.14 | 0.00 | 141.60 | 22.11 | 101.50 | 0.00 | 0.00 |
| Maximum of Months | 503.53 | 138.38 | 203.15 | 89.52 | 128.50 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 110.64 | 142.49 | 91.84 | 14.26 | 77.58 | 0.00 | 0.00 |
| February | 146.93 | 114.33 | 104.98 | 16.17 | 88.81 | 0.00 | 0.00 |
| March | 204.83 | 82.19 | 122.56 | 19.85 | 102.71 | 0.00 | 0.00 |
| April | 276.28 | 45.54 | 135.74 | 20.60 | 115.14 | 0.00 | 0.00 |
| May | 393.11 | 7.92 | 150.11 | 25.91 | 124.20 | 0.00 | 0.00 |
| June | 441.77 | 1.03 | 157.57 | 30.01 | 127.56 | 0.00 | 0.00 |
| July | 482.29 | 0.00 | 144.71 | 23.54 | 121.17 | 0.00 | 0.00 |
| August | 478.41 | 0.00 | 141.90 | 24.09 | 117.81 | 0.00 | 0.00 |
| September | 378.84 | 2.96 | 132.32 | 23.11 | 109.21 | 0.00 | 0.00 |
| October | 279.72 | 16.68 | 117.46 | 21.10 | 96.37 | 0.00 | 0.00 |
| November | 189.04 | 58.97 | 100.99 | 18.41 | 82.58 | 0.00 | 0.00 |
| December | 119.90 | 115.43 | 86.51 | 14.25 | 72.26 | 0.00 | 0.00 |
| Annual Sum or Average | 292.68 | 48.66 | 123.96 | 20.96 | 103.00 | 0.00 | 0.00 |
| Minimum of Months | 110.64 | 0.00 | 86.51 | 14.25 | 72.26 | 0.00 | 0.00 |
| Maximum of Months | 482.29 | 142.49 | 157.57 | 30.01 | 127.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 251.71 | 169.94 | 187.04 | 79.45 | 107.60 | 0.00 | 0.00 |
| February | 267.26 | 146.60 | 183.69 | 67.83 | 115.85 | 0.00 | 0.00 |
| March | 266.17 | 116.46 | 164.39 | 41.73 | 122.67 | 0.00 | 0.00 |
| April | 293.22 | 83.06 | 158.82 | 32.19 | 126.63 | 0.00 | 0.00 |
| May | 340.19 | 30.96 | 152.80 | 27.37 | 125.44 | 0.00 | 0.00 |
| June | 352.80 | 14.72 | 147.06 | 24.83 | 122.23 | 0.00 | 0.00 |
| July | 388.42 | 2.25 | 141.70 | 22.33 | 119.37 | 0.00 | 0.00 |
| August | 420.56 | 1.59 | 153.89 | 28.97 | 124.92 | 0.00 | 0.00 |
| September | 395.52 | 20.59 | 174.84 | 46.61 | 128.23 | 0.00 | 0.00 |
| October | 384.11 | 56.00 | 197.85 | 73.64 | 124.21 | 0.00 | 0.00 |
| November | 336.45 | 107.22 | 202.10 | 88.57 | 113.53 | 0.00 | 0.00 |
| December | 257.89 | 153.35 | 180.05 | 78.96 | 101.09 | 0.00 | 0.00 |
| Annual Sum or Average | 329.87 | 74.85 | 170.24 | 50.93 | 119.31 | 0.00 | 0.00 |
| Minimum of Months | 251.71 | 1.59 | 141.70 | 22.33 | 101.09 | 0.00 | 0.00 |
| Maximum of Months | 420.56 | 169.94 | 202.10 | 88.57 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 104.98 | 135.20 | 92.65 | 15.24 | 77.41 | 0.00 | 0.00 |
| February | 139.41 | 109.71 | 103.26 | 14.79 | 88.47 | 0.00 | 0.00 |
| March | 190.83 | 78.50 | 116.30 | 14.90 | 101.41 | 0.00 | 0.00 |
| April | 276.91 | 43.43 | 136.85 | 21.82 | 115.02 | 0.00 | 0.00 |
| May | 397.72 | 7.54 | 153.14 | 28.42 | 124.72 | 0.00 | 0.00 |
| June | 438.53 | 0.97 | 156.24 | 28.80 | 127.44 | 0.00 | 0.00 |
| July | 482.69 | 0.00 | 144.81 | 23.75 | 121.06 | 0.00 | 0.00 |
| August | 479.36 | 0.00 | 141.90 | 24.33 | 117.57 | 0.00 | 0.00 |
| September | 377.07 | 2.65 | 131.30 | 22.36 | 108.94 | 0.00 | 0.00 |
| October | 279.26 | 15.18 | 117.87 | 21.41 | 96.46 | 0.00 | 0.00 |
| November | 182.81 | 54.92 | 99.94 | 17.45 | 82.48 | 0.00 | 0.00 |
| December | 109.78 | 109.87 | 84.05 | 12.21 | 71.85 | 0.00 | 0.00 |
| Annual Sum or Average | 289.17 | 46.21 | 123.27 | 20.48 | 102.79 | 0.00 | 0.00 |
| Minimum of Months | 104.98 | 0.00 | 84.05 | 12.21 | 71.85 | 0.00 | 0.00 |
| Maximum of Months | 482.69 | 135.20 | 156.24 | 28.80 | 127.44 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 44.91 | 87.74 | 42.30 | 0.00 | 42.30 | 0.00 | 0.00 |
| February | 63.26 | 70.22 | 48.48 | 0.00 | 48.48 | 0.00 | 0.00 |
| March | 91.81 | 49.93 | 55.70 | 0.00 | 55.70 | 0.00 | 0.00 |
| April | 133.66 | 27.06 | 62.85 | 0.18 | 62.67 | 0.00 | 0.00 |
| May | 204.67 | 4.48 | 70.80 | 2.24 | 68.57 | 0.00 | 0.00 |
| June | 235.44 | 0.55 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
| July | 263.62 | 0.00 | 69.38 | 1.98 | 67.41 | 0.00 | 0.00 |
| August | 256.59 | 0.00 | 64.78 | 0.70 | 64.08 | 0.00 | 0.00 |
| September | 195.03 | 1.57 | 58.85 | 0.01 | 58.83 | 0.00 | 0.00 |
| October | 137.87 | 9.21 | 52.16 | 0.00 | 52.16 | 0.00 | 0.00 |
| November | 86.23 | 34.59 | 44.78 | 0.00 | 44.78 | 0.00 | 0.00 |
| December | 50.35 | 69.88 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Annual Sum or Average | 147.47 | 29.42 | 57.12 | 0.77 | 56.35 | 0.00 | 0.00 |
| Minimum of Months | 44.91 | 0.00 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Maximum of Months | 263.62 | 87.74 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 44.90 | 87.74 | 42.30 | 0.00 | 42.30 | 0.00 | 0.00 |
| February | 63.25 | 70.21 | 48.48 | 0.00 | 48.48 | 0.00 | 0.00 |
| March | 91.80 | 49.92 | 55.70 | 0.00 | 55.70 | 0.00 | 0.00 |
| April | 133.65 | 27.06 | 62.85 | 0.18 | 62.67 | 0.00 | 0.00 |
| May | 204.65 | 4.48 | 70.80 | 2.24 | 68.57 | 0.00 | 0.00 |
| June | 235.43 | 0.55 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
| July | 263.62 | 0.00 | 69.38 | 1.98 | 67.41 | 0.00 | 0.00 |
| August | 256.58 | 0.00 | 64.78 | 0.70 | 64.08 | 0.00 | 0.00 |
| September | 195.02 | 1.57 | 58.85 | 0.01 | 58.83 | 0.00 | 0.00 |
| October | 137.86 | 9.20 | 52.16 | 0.00 | 52.16 | 0.00 | 0.00 |
| November | 86.22 | 34.59 | 44.78 | 0.00 | 44.78 | 0.00 | 0.00 |
| December | 50.34 | 69.87 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Annual Sum or Average | 147.46 | 29.41 | 57.12 | 0.77 | 56.35 | 0.00 | 0.00 |
| Minimum of Months | 44.90 | 0.00 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Maximum of Months | 263.62 | 87.74 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 204.45 | 82.74 | 136.69 | 64.21 | 72.49 | 0.00 | 0.00 |
| February | 205.51 | 68.49 | 128.91 | 53.05 | 75.86 | 0.00 | 0.00 |
| March | 185.09 | 50.40 | 103.79 | 26.83 | 76.96 | 0.00 | 0.00 |
| April | 180.32 | 27.78 | 84.82 | 10.55 | 74.27 | 0.00 | 0.00 |
| May | 203.85 | 4.54 | 70.47 | 1.18 | 69.28 | 0.00 | 0.00 |
| June | 216.89 | 0.45 | 66.29 | 0.12 | 66.17 | 0.00 | 0.00 |
| July | 256.01 | 0.00 | 66.27 | 0.55 | 65.72 | 0.00 | 0.00 |
| August | 281.88 | 0.00 | 76.77 | 5.34 | 71.43 | 0.00 | 0.00 |
| September | 282.36 | 1.58 | 102.39 | 24.27 | 78.12 | 0.00 | 0.00 |
| October | 287.65 | 8.98 | 132.13 | 52.22 | 79.91 | 0.00 | 0.00 |
| November | 268.07 | 33.83 | 146.94 | 71.12 | 75.82 | 0.00 | 0.00 |
| December | 215.81 | 67.28 | 135.47 | 66.76 | 68.72 | 0.00 | 0.00 |
| Annual Sum or Average | 232.49 | 28.65 | 104.09 | 31.22 | 72.86 | 0.00 | 0.00 |
| Minimum of Months | 180.32 | 0.00 | 66.27 | 0.12 | 65.72 | 0.00 | 0.00 |
| Maximum of Months | 287.65 | 82.74 | 146.94 | 71.12 | 79.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 203.96 | 83.45 | 136.69 | 64.21 | 72.49 | 0.00 | 0.00 |
| February | 205.00 | 69.24 | 128.91 | 53.05 | 75.86 | 0.00 | 0.00 |
| March | 184.49 | 51.19 | 103.79 | 26.83 | 76.96 | 0.00 | 0.00 |
| April | 179.43 | 28.61 | 84.82 | 10.55 | 74.27 | 0.00 | 0.00 |
| May | 202.24 | 4.90 | 70.47 | 1.18 | 69.28 | 0.00 | 0.00 |
| June | 215.03 | 0.53 | 66.29 | 0.12 | 66.17 | 0.00 | 0.00 |
| July | 254.05 | 0.00 | 66.27 | 0.55 | 65.72 | 0.00 | 0.00 |
| August | 280.00 | 0.00 | 76.77 | 5.34 | 71.43 | 0.00 | 0.00 |
| September | 280.60 | 1.73 | 102.39 | 24.27 | 78.12 | 0.00 | 0.00 |
| October | 286.32 | 9.60 | 132.13 | 52.22 | 79.91 | 0.00 | 0.00 |
| November | 267.17 | 34.82 | 146.94 | 71.12 | 75.82 | 0.00 | 0.00 |
| December | 215.23 | 68.16 | 135.47 | 66.76 | 68.72 | 0.00 | 0.00 |
| Annual Sum or Average | 231.29 | 29.17 | 104.09 | 31.22 | 72.86 | 0.00 | 0.00 |
| Minimum of Months | 179.43 | 0.00 | 66.27 | 0.12 | 65.72 | 0.00 | 0.00 |
| Maximum of Months | 286.32 | 83.45 | 146.94 | 71.12 | 79.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 267.98 | 136.08 | 186.23 | 78.47 | 107.77 | 0.00 | 0.00 |
| February | 287.12 | 112.71 | 185.40 | 69.21 | 116.19 | 0.00 | 0.00 |
| March | 295.85 | 83.26 | 170.65 | 46.67 | 123.97 | 0.00 | 0.00 |
| April | 321.82 | 46.16 | 157.70 | 30.96 | 126.74 | 0.00 | 0.00 |
| May | 395.73 | 7.39 | 149.78 | 24.86 | 124.91 | 0.00 | 0.00 |
| June | 430.02 | 0.69 | 148.38 | 26.04 | 122.34 | 0.00 | 0.00 |
| July | 484.02 | 0.00 | 141.60 | 22.11 | 119.49 | 0.00 | 0.00 |
| August | 515.43 | 0.00 | 153.89 | 28.73 | 125.16 | 0.00 | 0.00 |
| September | 475.91 | 2.15 | 175.87 | 47.37 | 128.50 | 0.00 | 0.00 |
| October | 435.53 | 12.92 | 197.44 | 73.32 | 124.12 | 0.00 | 0.00 |
| November | 372.45 | 52.60 | 203.15 | 89.52 | 113.62 | 0.00 | 0.00 |
| December | 284.18 | 108.87 | 182.50 | 81.00 | 101.50 | 0.00 | 0.00 |
| Annual Sum or Average | 381.06 | 46.60 | 170.93 | 51.41 | 119.52 | 0.00 | 0.00 |
| Minimum of Months | 267.98 | 0.00 | 141.60 | 22.11 | 101.50 | 0.00 | 0.00 |
| Maximum of Months | 515.43 | 136.08 | 203.15 | 89.52 | 128.50 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 111.40 | 140.06 | 91.84 | 14.26 | 77.58 | 0.00 | 0.00 |
| February | 146.68 | 113.61 | 104.98 | 16.17 | 88.81 | 0.00 | 0.00 |
| March | 203.75 | 82.61 | 122.56 | 19.85 | 102.71 | 0.00 | 0.00 |
| April | 275.87 | 45.43 | 135.74 | 20.60 | 115.14 | 0.00 | 0.00 |
| May | 396.48 | 7.30 | 150.11 | 25.91 | 124.20 | 0.00 | 0.00 |
| June | 448.12 | 0.79 | 157.57 | 30.01 | 127.56 | 0.00 | 0.00 |
| July | 491.69 | 0.00 | 144.71 | 23.54 | 121.17 | 0.00 | 0.00 |
| August | 490.59 | 0.00 | 141.90 | 24.09 | 117.81 | 0.00 | 0.00 |
| September | 389.98 | 2.14 | 132.32 | 23.11 | 109.21 | 0.00 | 0.00 |
| October | 288.10 | 13.22 | 117.46 | 21.10 | 96.37 | 0.00 | 0.00 |
| November | 193.76 | 53.68 | 100.99 | 18.41 | 82.58 | 0.00 | 0.00 |
| December | 121.74 | 111.44 | 86.51 | 14.25 | 72.26 | 0.00 | 0.00 |
| Annual Sum or Average | 297.41 | 47.22 | 123.96 | 20.96 | 103.00 | 0.00 | 0.00 |
| Minimum of Months | 111.40 | 0.00 | 86.51 | 14.25 | 72.26 | 0.00 | 0.00 |
| Maximum of Months | 491.69 | 140.06 | 157.57 | 30.01 | 127.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 266.61 | 132.93 | 187.04 | 79.45 | 107.60 | 0.00 | 0.00 |
| February | 281.36 | 109.72 | 183.69 | 67.83 | 115.85 | 0.00 | 0.00 |
| March | 282.41 | 80.01 | 164.39 | 41.73 | 122.67 | 0.00 | 0.00 |
| April | 322.20 | 43.67 | 158.82 | 32.19 | 126.63 | 0.00 | 0.00 |
| May | 399.97 | 6.66 | 152.80 | 27.37 | 125.44 | 0.00 | 0.00 |
| June | 426.58 | 0.60 | 147.06 | 24.83 | 122.23 | 0.00 | 0.00 |
| July | 484.40 | 0.00 | 141.70 | 22.33 | 119.37 | 0.00 | 0.00 |
| August | 516.46 | 0.00 | 153.89 | 28.97 | 124.92 | 0.00 | 0.00 |
| September | 474.26 | 1.93 | 174.84 | 46.61 | 128.23 | 0.00 | 0.00 |
| October | 435.84 | 12.10 | 197.85 | 73.64 | 124.21 | 0.00 | 0.00 |
| November | 369.07 | 51.40 | 202.10 | 88.57 | 113.53 | 0.00 | 0.00 |
| December | 277.93 | 107.12 | 180.05 | 78.96 | 101.09 | 0.00 | 0.00 |
| Annual Sum or Average | 378.67 | 45.22 | 170.24 | 50.93 | 119.31 | 0.00 | 0.00 |
| Minimum of Months | 266.61 | 0.00 | 141.70 | 22.33 | 101.09 | 0.00 | 0.00 |
| Maximum of Months | 516.46 | 132.93 | 202.10 | 88.57 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 105.81 | 132.89 | 92.65 | 15.24 | 77.41 | 0.00 | 0.00 |
| February | 139.25 | 109.01 | 103.26 | 14.79 | 88.47 | 0.00 | 0.00 |
| March | 189.88 | 78.92 | 116.30 | 14.90 | 101.41 | 0.00 | 0.00 |
| April | 276.57 | 43.27 | 136.85 | 21.82 | 115.02 | 0.00 | 0.00 |
| May | 401.08 | 6.91 | 153.14 | 28.42 | 124.72 | 0.00 | 0.00 |
| June | 444.72 | 0.72 | 156.24 | 28.80 | 127.44 | 0.00 | 0.00 |
| July | 492.09 | 0.00 | 144.81 | 23.75 | 121.06 | 0.00 | 0.00 |
| August | 491.63 | 0.00 | 141.90 | 24.33 | 117.57 | 0.00 | 0.00 |
| September | 388.32 | 1.90 | 131.30 | 22.36 | 108.94 | 0.00 | 0.00 |
| October | 287.88 | 11.90 | 117.87 | 21.41 | 96.46 | 0.00 | 0.00 |
| November | 187.79 | 49.91 | 99.94 | 17.45 | 82.48 | 0.00 | 0.00 |
| December | 111.78 | 106.02 | 84.05 | 12.21 | 71.85 | 0.00 | 0.00 |
| Annual Sum or Average | 293.99 | 44.83 | 123.27 | 20.48 | 102.79 | 0.00 | 0.00 |
| Minimum of Months | 105.81 | 0.00 | 84.05 | 12.21 | 71.85 | 0.00 | 0.00 |
| Maximum of Months | 492.09 | 132.89 | 156.24 | 28.80 | 127.44 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 45.14 | 87.06 | 42.30 | 0.00 | 42.30 | 0.00 | 0.00 |
| February | 63.23 | 70.01 | 48.48 | 0.00 | 48.48 | 0.00 | 0.00 |
| March | 91.60 | 50.01 | 55.70 | 0.00 | 55.70 | 0.00 | 0.00 |
| April | 133.94 | 26.82 | 62.85 | 0.18 | 62.67 | 0.00 | 0.00 |
| May | 206.98 | 4.13 | 70.80 | 2.24 | 68.57 | 0.00 | 0.00 |
| June | 239.17 | 0.43 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
| July | 268.89 | 0.00 | 69.38 | 1.98 | 67.41 | 0.00 | 0.00 |
| August | 263.09 | 0.00 | 64.78 | 0.70 | 64.08 | 0.00 | 0.00 |
| September | 200.92 | 1.19 | 58.85 | 0.01 | 58.83 | 0.00 | 0.00 |
| October | 142.29 | 7.60 | 52.16 | 0.00 | 52.16 | 0.00 | 0.00 |
| November | 88.68 | 32.15 | 44.78 | 0.00 | 44.78 | 0.00 | 0.00 |
| December | 51.18 | 68.19 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Annual Sum or Average | 150.13 | 28.78 | 57.12 | 0.77 | 56.35 | 0.00 | 0.00 |
| Minimum of Months | 45.14 | 0.00 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Maximum of Months | 268.89 | 87.06 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 45.12 | 87.06 | 42.30 | 0.00 | 42.30 | 0.00 | 0.00 |
| February | 63.22 | 70.00 | 48.48 | 0.00 | 48.48 | 0.00 | 0.00 |
| March | 91.60 | 50.00 | 55.70 | 0.00 | 55.70 | 0.00 | 0.00 |
| April | 133.93 | 26.82 | 62.85 | 0.18 | 62.67 | 0.00 | 0.00 |
| May | 206.97 | 4.13 | 70.80 | 2.24 | 68.57 | 0.00 | 0.00 |
| June | 239.16 | 0.43 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
| July | 268.89 | 0.00 | 69.38 | 1.98 | 67.41 | 0.00 | 0.00 |
| August | 263.09 | 0.00 | 64.78 | 0.70 | 64.08 | 0.00 | 0.00 |
| September | 200.92 | 1.19 | 58.85 | 0.01 | 58.83 | 0.00 | 0.00 |
| October | 142.29 | 7.60 | 52.16 | 0.00 | 52.16 | 0.00 | 0.00 |
| November | 88.68 | 32.15 | 44.78 | 0.00 | 44.78 | 0.00 | 0.00 |
| December | 51.17 | 68.19 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Annual Sum or Average | 150.12 | 28.78 | 57.12 | 0.77 | 56.35 | 0.00 | 0.00 |
| Minimum of Months | 45.12 | 0.00 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Maximum of Months | 268.89 | 87.06 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 203.93 | 81.85 | 136.69 | 64.21 | 72.49 | 0.00 | 0.00 |
| February | 204.80 | 67.94 | 128.91 | 53.05 | 75.86 | 0.00 | 0.00 |
| March | 184.49 | 50.18 | 103.79 | 26.83 | 76.96 | 0.00 | 0.00 |
| April | 180.29 | 27.37 | 84.82 | 10.55 | 74.27 | 0.00 | 0.00 |
| May | 206.14 | 4.14 | 70.47 | 1.18 | 69.28 | 0.00 | 0.00 |
| June | 220.86 | 0.33 | 66.29 | 0.12 | 66.17 | 0.00 | 0.00 |
| July | 261.12 | 0.00 | 66.27 | 0.55 | 65.72 | 0.00 | 0.00 |
| August | 288.19 | 0.00 | 76.77 | 5.34 | 71.43 | 0.00 | 0.00 |
| September | 287.69 | 1.17 | 102.39 | 24.27 | 78.12 | 0.00 | 0.00 |
| October | 291.25 | 7.21 | 132.13 | 52.22 | 79.91 | 0.00 | 0.00 |
| November | 269.59 | 31.12 | 146.94 | 71.12 | 75.82 | 0.00 | 0.00 |
| December | 215.98 | 65.44 | 135.47 | 66.76 | 68.72 | 0.00 | 0.00 |
| Annual Sum or Average | 234.72 | 27.88 | 104.09 | 31.22 | 72.86 | 0.00 | 0.00 |
| Minimum of Months | 180.29 | 0.00 | 66.27 | 0.12 | 65.72 | 0.00 | 0.00 |
| Maximum of Months | 291.25 | 81.85 | 146.94 | 71.12 | 79.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 203.92 | 81.85 | 136.69 | 64.21 | 72.49 | 0.00 | 0.00 |
| February | 204.79 | 67.94 | 128.91 | 53.05 | 75.86 | 0.00 | 0.00 |
| March | 184.49 | 50.17 | 103.79 | 26.83 | 76.96 | 0.00 | 0.00 |
| April | 180.28 | 27.37 | 84.82 | 10.55 | 74.27 | 0.00 | 0.00 |
| May | 206.13 | 4.14 | 70.47 | 1.18 | 69.28 | 0.00 | 0.00 |
| June | 220.86 | 0.33 | 66.29 | 0.12 | 66.17 | 0.00 | 0.00 |
| July | 261.12 | 0.00 | 66.27 | 0.55 | 65.72 | 0.00 | 0.00 |
| August | 288.18 | 0.00 | 76.77 | 5.34 | 71.43 | 0.00 | 0.00 |
| September | 287.68 | 1.17 | 102.39 | 24.27 | 78.12 | 0.00 | 0.00 |
| October | 291.25 | 7.21 | 132.13 | 52.22 | 79.91 | 0.00 | 0.00 |
| November | 269.58 | 31.11 | 146.94 | 71.12 | 75.82 | 0.00 | 0.00 |
| December | 215.97 | 65.44 | 135.47 | 66.76 | 68.72 | 0.00 | 0.00 |
| Annual Sum or Average | 234.71 | 27.88 | 104.09 | 31.22 | 72.86 | 0.00 | 0.00 |
| Minimum of Months | 180.28 | 0.00 | 66.27 | 0.12 | 65.72 | 0.00 | 0.00 |
| Maximum of Months | 291.25 | 81.85 | 146.94 | 71.12 | 79.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 269.56 | 123.04 | 186.23 | 78.47 | 107.77 | 0.00 | 0.00 |
| February | 285.55 | 103.47 | 185.40 | 69.21 | 116.19 | 0.00 | 0.00 |
| March | 291.54 | 77.90 | 170.65 | 46.67 | 123.97 | 0.00 | 0.00 |
| April | 314.76 | 43.87 | 157.70 | 30.96 | 126.74 | 0.00 | 0.00 |
| May | 385.59 | 6.85 | 149.78 | 24.86 | 124.91 | 0.00 | 0.00 |
| June | 419.18 | 0.61 | 148.38 | 26.04 | 122.34 | 0.00 | 0.00 |
| July | 471.18 | 0.00 | 141.60 | 22.11 | 119.49 | 0.00 | 0.00 |
| August | 502.45 | 0.00 | 153.89 | 28.73 | 125.16 | 0.00 | 0.00 |
| September | 465.28 | 1.92 | 175.87 | 47.37 | 128.50 | 0.00 | 0.00 |
| October | 426.98 | 11.75 | 197.44 | 73.32 | 124.12 | 0.00 | 0.00 |
| November | 366.76 | 49.63 | 203.15 | 89.52 | 113.62 | 0.00 | 0.00 |
| December | 283.07 | 100.90 | 182.50 | 81.00 | 101.50 | 0.00 | 0.00 |
| Annual Sum or Average | 374.02 | 43.04 | 170.93 | 51.41 | 119.52 | 0.00 | 0.00 |
| Minimum of Months | 269.56 | 0.00 | 141.60 | 22.11 | 101.50 | 0.00 | 0.00 |
| Maximum of Months | 502.45 | 123.04 | 203.15 | 89.52 | 128.50 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 114.68 | 124.08 | 91.84 | 14.26 | 77.58 | 0.00 | 0.00 |
| February | 146.89 | 103.25 | 104.98 | 16.17 | 88.81 | 0.00 | 0.00 |
| March | 200.58 | 77.10 | 122.56 | 19.85 | 102.71 | 0.00 | 0.00 |
| April | 269.41 | 43.32 | 135.74 | 20.60 | 115.14 | 0.00 | 0.00 |
| May | 386.31 | 6.83 | 150.11 | 25.91 | 124.20 | 0.00 | 0.00 |
| June | 436.98 | 0.71 | 157.57 | 30.01 | 127.56 | 0.00 | 0.00 |
| July | 478.82 | 0.00 | 144.71 | 23.54 | 121.17 | 0.00 | 0.00 |
| August | 477.81 | 0.00 | 141.90 | 24.09 | 117.81 | 0.00 | 0.00 |
| September | 380.12 | 1.95 | 132.32 | 23.11 | 109.21 | 0.00 | 0.00 |
| October | 281.03 | 12.26 | 117.46 | 21.10 | 96.37 | 0.00 | 0.00 |
| November | 189.98 | 50.64 | 100.99 | 18.41 | 82.58 | 0.00 | 0.00 |
| December | 122.31 | 101.73 | 86.51 | 14.25 | 72.26 | 0.00 | 0.00 |
| Annual Sum or Average | 291.28 | 43.21 | 123.96 | 20.96 | 103.00 | 0.00 | 0.00 |
| Minimum of Months | 114.68 | 0.00 | 86.51 | 14.25 | 72.26 | 0.00 | 0.00 |
| Maximum of Months | 478.82 | 124.08 | 157.57 | 30.01 | 127.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 268.59 | 120.73 | 187.04 | 79.45 | 107.60 | 0.00 | 0.00 |
| February | 280.27 | 101.10 | 183.69 | 67.83 | 115.85 | 0.00 | 0.00 |
| March | 278.59 | 75.04 | 164.39 | 41.73 | 122.67 | 0.00 | 0.00 |
| April | 315.31 | 41.52 | 158.82 | 32.19 | 126.63 | 0.00 | 0.00 |
| May | 389.85 | 6.17 | 152.80 | 27.37 | 125.44 | 0.00 | 0.00 |
| June | 415.67 | 0.52 | 147.06 | 24.83 | 122.23 | 0.00 | 0.00 |
| July | 471.56 | 0.00 | 141.70 | 22.33 | 119.37 | 0.00 | 0.00 |
| August | 503.52 | 0.00 | 153.89 | 28.97 | 124.92 | 0.00 | 0.00 |
| September | 463.69 | 1.72 | 174.84 | 46.61 | 128.23 | 0.00 | 0.00 |
| October | 427.30 | 10.95 | 197.85 | 73.64 | 124.21 | 0.00 | 0.00 |
| November | 363.47 | 48.52 | 202.10 | 88.57 | 113.53 | 0.00 | 0.00 |
| December | 277.03 | 99.45 | 180.05 | 78.96 | 101.09 | 0.00 | 0.00 |
| Annual Sum or Average | 371.79 | 41.87 | 170.24 | 50.93 | 119.31 | 0.00 | 0.00 |
| Minimum of Months | 268.59 | 0.00 | 141.70 | 22.33 | 101.09 | 0.00 | 0.00 |
| Maximum of Months | 503.52 | 120.73 | 202.10 | 88.57 | 128.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 110.53 | 118.85 | 92.65 | 15.24 | 77.41 | 0.00 | 0.00 |
| February | 140.28 | 99.71 | 103.26 | 14.79 | 88.47 | 0.00 | 0.00 |
| March | 187.25 | 73.88 | 116.30 | 14.90 | 101.41 | 0.00 | 0.00 |
| April | 270.27 | 41.27 | 136.85 | 21.82 | 115.02 | 0.00 | 0.00 |
| May | 390.90 | 6.44 | 153.14 | 28.42 | 124.72 | 0.00 | 0.00 |
| June | 433.54 | 0.64 | 156.24 | 28.80 | 127.44 | 0.00 | 0.00 |
| July | 479.22 | 0.00 | 144.81 | 23.75 | 121.06 | 0.00 | 0.00 |
| August | 478.91 | 0.00 | 141.90 | 24.33 | 117.57 | 0.00 | 0.00 |
| September | 378.51 | 1.73 | 131.30 | 22.36 | 108.94 | 0.00 | 0.00 |
| October | 280.86 | 10.99 | 117.87 | 21.41 | 96.46 | 0.00 | 0.00 |
| November | 184.31 | 47.22 | 99.94 | 17.45 | 82.48 | 0.00 | 0.00 |
| December | 113.28 | 97.40 | 84.05 | 12.21 | 71.85 | 0.00 | 0.00 |
| Annual Sum or Average | 288.21 | 41.24 | 123.27 | 20.48 | 102.79 | 0.00 | 0.00 |
| Minimum of Months | 110.53 | 0.00 | 84.05 | 12.21 | 71.85 | 0.00 | 0.00 |
| Maximum of Months | 479.22 | 118.85 | 156.24 | 28.80 | 127.44 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 47.04 | 78.99 | 42.30 | 0.00 | 42.30 | 0.00 | 0.00 |
| February | 63.46 | 65.25 | 48.48 | 0.00 | 48.48 | 0.00 | 0.00 |
| March | 90.15 | 47.55 | 55.70 | 0.00 | 55.70 | 0.00 | 0.00 |
| April | 130.79 | 25.95 | 62.85 | 0.18 | 62.67 | 0.00 | 0.00 |
| May | 201.76 | 3.97 | 70.80 | 2.24 | 68.57 | 0.00 | 0.00 |
| June | 233.33 | 0.41 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
| July | 262.13 | 0.00 | 69.38 | 1.98 | 67.41 | 0.00 | 0.00 |
| August | 256.43 | 0.00 | 64.78 | 0.70 | 64.08 | 0.00 | 0.00 |
| September | 195.87 | 1.12 | 58.85 | 0.01 | 58.83 | 0.00 | 0.00 |
| October | 138.83 | 7.21 | 52.16 | 0.00 | 52.16 | 0.00 | 0.00 |
| November | 86.97 | 30.76 | 44.78 | 0.00 | 44.78 | 0.00 | 0.00 |
| December | 51.56 | 63.68 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Annual Sum or Average | 147.04 | 26.90 | 57.12 | 0.77 | 56.35 | 0.00 | 0.00 |
| Minimum of Months | 47.04 | 0.00 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Maximum of Months | 262.13 | 78.99 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 46.97 | 78.97 | 42.30 | 0.00 | 42.30 | 0.00 | 0.00 |
| February | 63.41 | 65.23 | 48.48 | 0.00 | 48.48 | 0.00 | 0.00 |
| March | 90.13 | 47.53 | 55.70 | 0.00 | 55.70 | 0.00 | 0.00 |
| April | 130.76 | 25.94 | 62.85 | 0.18 | 62.67 | 0.00 | 0.00 |
| May | 201.74 | 3.97 | 70.80 | 2.24 | 68.57 | 0.00 | 0.00 |
| June | 233.32 | 0.41 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
| July | 262.12 | 0.00 | 69.38 | 1.98 | 67.41 | 0.00 | 0.00 |
| August | 256.43 | 0.00 | 64.78 | 0.70 | 64.08 | 0.00 | 0.00 |
| September | 195.87 | 1.12 | 58.85 | 0.01 | 58.83 | 0.00 | 0.00 |
| October | 138.82 | 7.20 | 52.16 | 0.00 | 52.16 | 0.00 | 0.00 |
| November | 86.95 | 30.75 | 44.78 | 0.00 | 44.78 | 0.00 | 0.00 |
| December | 51.53 | 63.65 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Annual Sum or Average | 147.02 | 26.89 | 57.12 | 0.77 | 56.35 | 0.00 | 0.00 |
| Minimum of Months | 46.97 | 0.00 | 39.48 | 0.00 | 39.48 | 0.00 | 0.00 |
| Maximum of Months | 262.12 | 78.97 | 75.48 | 4.09 | 71.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 204.62 | 76.07 | 136.69 | 64.21 | 72.49 | 0.00 | 0.00 |
| February | 203.79 | 63.96 | 128.91 | 53.05 | 75.86 | 0.00 | 0.00 |
| March | 182.27 | 47.83 | 103.79 | 26.83 | 76.96 | 0.00 | 0.00 |
| April | 176.71 | 26.39 | 84.82 | 10.55 | 74.27 | 0.00 | 0.00 |
| May | 200.94 | 3.93 | 70.47 | 1.18 | 69.28 | 0.00 | 0.00 |
| June | 215.25 | 0.30 | 66.29 | 0.12 | 66.17 | 0.00 | 0.00 |
| July | 254.36 | 0.00 | 66.27 | 0.55 | 65.72 | 0.00 | 0.00 |
| August | 281.39 | 0.00 | 76.77 | 5.34 | 71.43 | 0.00 | 0.00 |
| September | 282.11 | 1.08 | 102.39 | 24.27 | 78.12 | 0.00 | 0.00 |
| October | 286.74 | 6.67 | 132.13 | 52.22 | 79.91 | 0.00 | 0.00 |
| November | 266.52 | 29.74 | 146.94 | 71.12 | 75.82 | 0.00 | 0.00 |
| December | 215.20 | 62.02 | 135.47 | 66.76 | 68.72 | 0.00 | 0.00 |
| Annual Sum or Average | 231.00 | 26.32 | 104.09 | 31.22 | 72.86 | 0.00 | 0.00 |
| Minimum of Months | 176.71 | 0.00 | 66.27 | 0.12 | 65.72 | 0.00 | 0.00 |
| Maximum of Months | 286.74 | 76.07 | 146.94 | 71.12 | 79.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 204.57 | 76.05 | 136.69 | 64.21 | 72.49 | 0.00 | 0.00 |
| February | 203.76 | 63.94 | 128.91 | 53.05 | 75.86 | 0.00 | 0.00 |
| March | 182.25 | 47.81 | 103.79 | 26.83 | 76.96 | 0.00 | 0.00 |
| April | 176.69 | 26.37 | 84.82 | 10.55 | 74.27 | 0.00 | 0.00 |
| May | 200.92 | 3.92 | 70.47 | 1.18 | 69.28 | 0.00 | 0.00 |
| June | 215.24 | 0.30 | 66.29 | 0.12 | 66.17 | 0.00 | 0.00 |
| July | 254.36 | 0.00 | 66.27 | 0.55 | 65.72 | 0.00 | 0.00 |
| August | 281.38 | 0.00 | 76.77 | 5.34 | 71.43 | 0.00 | 0.00 |
| September | 282.10 | 1.08 | 102.39 | 24.27 | 78.12 | 0.00 | 0.00 |
| October | 286.73 | 6.67 | 132.13 | 52.22 | 79.91 | 0.00 | 0.00 |
| November | 266.51 | 29.73 | 146.94 | 71.12 | 75.82 | 0.00 | 0.00 |
| December | 215.17 | 62.00 | 135.47 | 66.76 | 68.72 | 0.00 | 0.00 |
| Annual Sum or Average | 230.98 | 26.32 | 104.09 | 31.22 | 72.86 | 0.00 | 0.00 |
| Minimum of Months | 176.69 | 0.00 | 66.27 | 0.12 | 65.72 | 0.00 | 0.00 |
| Maximum of Months | 286.73 | 76.05 | 146.94 | 71.12 | 79.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.20 | 13.56 | 12.08 | 3.66 | 8.42 | 0.00 | 0.00 |
| February | 18.01 | 11.58 | 13.14 | 3.55 | 9.60 | 0.00 | 0.00 |
| March | 22.62 | 8.81 | 14.54 | 3.57 | 10.97 | 0.00 | 0.00 |
| April | 32.38 | 5.41 | 17.76 | 5.19 | 12.56 | 0.00 | 0.00 |
| May | 43.17 | 1.18 | 19.76 | 6.28 | 13.47 | 0.00 | 0.00 |
| June | 45.37 | 0.24 | 19.38 | 5.93 | 13.45 | 0.00 | 0.00 |
| July | 48.99 | 0.00 | 18.10 | 5.23 | 12.87 | 0.00 | 0.00 |
| August | 50.20 | 0.00 | 18.51 | 5.67 | 12.84 | 0.00 | 0.00 |
| September | 41.01 | 0.39 | 17.38 | 5.36 | 12.02 | 0.00 | 0.00 |
| October | 32.14 | 1.92 | 15.77 | 5.14 | 10.63 | 0.00 | 0.00 |
| November | 22.54 | 6.19 | 13.24 | 4.19 | 9.05 | 0.00 | 0.00 |
| December | 14.44 | 11.45 | 10.70 | 2.93 | 7.77 | 0.00 | 0.00 |
| Annual Sum or Average | 32.25 | 5.03 | 15.87 | 4.73 | 11.14 | 0.00 | 0.00 |
| Minimum of Months | 14.44 | 0.00 | 10.70 | 2.93 | 7.77 | 0.00 | 0.00 |
| Maximum of Months | 50.20 | 13.56 | 19.76 | 6.28 | 13.47 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 43.37 | 43.57 | 35.98 | 10.89 | 25.09 | 0.00 | 0.00 |
| February | 52.37 | 36.81 | 39.15 | 10.57 | 28.58 | 0.00 | 0.00 |
| March | 66.20 | 28.14 | 43.31 | 10.64 | 32.67 | 0.00 | 0.00 |
| April | 94.32 | 18.38 | 52.88 | 15.47 | 37.42 | 0.00 | 0.00 |
| May | 122.75 | 5.33 | 58.84 | 18.71 | 40.13 | 0.00 | 0.00 |
| June | 127.20 | 1.93 | 57.72 | 17.66 | 40.06 | 0.00 | 0.00 |
| July | 135.36 | 0.10 | 53.90 | 15.56 | 38.34 | 0.00 | 0.00 |
| August | 137.88 | 0.06 | 55.12 | 16.89 | 38.23 | 0.00 | 0.00 |
| September | 112.94 | 2.64 | 51.78 | 15.97 | 35.81 | 0.00 | 0.00 |
| October | 89.92 | 9.67 | 46.96 | 15.30 | 31.66 | 0.00 | 0.00 |
| November | 63.99 | 23.10 | 39.42 | 12.47 | 26.95 | 0.00 | 0.00 |
| December | 41.06 | 37.67 | 31.86 | 8.72 | 23.13 | 0.00 | 0.00 |
| Annual Sum or Average | 90.83 | 17.18 | 47.27 | 14.09 | 33.19 | 0.00 | 0.00 |
| Minimum of Months | 41.06 | 0.06 | 31.86 | 8.72 | 23.13 | 0.00 | 0.00 |
| Maximum of Months | 137.88 | 43.57 | 58.84 | 18.71 | 40.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 14.16 | 14.93 | 12.08 | 3.66 | 8.42 | 0.00 | 0.00 |
| February | 17.36 | 12.52 | 13.14 | 3.55 | 9.60 | 0.00 | 0.00 |
| March | 22.39 | 9.36 | 14.54 | 3.57 | 10.97 | 0.00 | 0.00 |
| April | 32.66 | 5.62 | 17.76 | 5.19 | 12.56 | 0.00 | 0.00 |
| May | 44.18 | 1.22 | 19.76 | 6.28 | 13.47 | 0.00 | 0.00 |
| June | 46.60 | 0.26 | 19.38 | 5.93 | 13.45 | 0.00 | 0.00 |
| July | 50.64 | 0.00 | 18.10 | 5.23 | 12.87 | 0.00 | 0.00 |
| August | 51.87 | 0.00 | 18.51 | 5.67 | 12.84 | 0.00 | 0.00 |
| September | 42.12 | 0.42 | 17.38 | 5.36 | 12.02 | 0.00 | 0.00 |
| October | 32.73 | 2.05 | 15.77 | 5.14 | 10.63 | 0.00 | 0.00 |
| November | 22.53 | 6.53 | 13.24 | 4.19 | 9.05 | 0.00 | 0.00 |
| December | 13.82 | 12.35 | 10.70 | 2.93 | 7.77 | 0.00 | 0.00 |
| Annual Sum or Average | 32.68 | 5.41 | 15.87 | 4.73 | 11.14 | 0.00 | 0.00 |
| Minimum of Months | 13.82 | 0.00 | 10.70 | 2.93 | 7.77 | 0.00 | 0.00 |
| Maximum of Months | 51.87 | 14.93 | 19.76 | 6.28 | 13.47 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.718196E+09 | 0.370629E+09 | 0.498811E+09 | 0.210162E+09 | 0.288649E+09 | 0.00 | 0.00 |
| February | 0.696850E+09 | 0.275335E+09 | 0.448527E+09 | 0.167433E+09 | 0.281094E+09 | 0.00 | 0.00 |
| March | 0.796115E+09 | 0.223011E+09 | 0.457065E+09 | 0.125013E+09 | 0.332052E+09 | 0.00 | 0.00 |
| April | 0.836018E+09 | 0.120406E+09 | 0.408771E+09 | 80259925.74 | 0.328511E+09 | 0.00 | 0.00 |
| May | 0.105125E+10 | 21580649.67 | 0.401160E+09 | 66590909.35 | 0.334569E+09 | 0.00 | 0.00 |
| June | 0.109793E+10 | 2396245.51 | 0.384610E+09 | 67499209.79 | 0.317111E+09 | 0.00 | 0.00 |
| July | 0.127198E+10 | 0.00 | 0.379261E+09 | 59231911.06 | 0.320029E+09 | 0.00 | 0.00 |
| August | 0.134865E+10 | 0.00 | 0.412180E+09 | 76944871.39 | 0.335235E+09 | 0.00 | 0.00 |
| September | 0.120623E+10 | 7800397.19 | 0.455842E+09 | 0.122774E+09 | 0.333068E+09 | 0.00 | 0.00 |
| October | 0.114641E+10 | 44474629.32 | 0.528826E+09 | 0.196384E+09 | 0.332442E+09 | 0.00 | 0.00 |
| November | 0.955587E+09 | 0.150892E+09 | 0.526552E+09 | 0.232043E+09 | 0.294509E+09 | 0.00 | 0.00 |
| December | 0.758208E+09 | 0.302406E+09 | 0.488813E+09 | 0.216953E+09 | 0.271860E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.118834E+11 | 0.151893E+10 | 0.539042E+10 | 0.162129E+10 | 0.376913E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.696850E+09 | 0.00 | 0.379261E+09 | 59231911.06 | 0.271860E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.134865E+10 | 0.370629E+09 | 0.528826E+09 | 0.232043E+09 | 0.335235E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.296330E+09 | 0.381635E+09 | 0.245981E+09 | 38193560.46 | 0.207788E+09 | 0.00 | 0.00 |
| February | 0.355450E+09 | 0.276577E+09 | 0.253965E+09 | 39106376.58 | 0.214858E+09 | 0.00 | 0.00 |
| March | 0.548603E+09 | 0.220148E+09 | 0.328264E+09 | 53156512.56 | 0.275108E+09 | 0.00 | 0.00 |
| April | 0.716114E+09 | 0.118027E+09 | 0.351832E+09 | 53395757.12 | 0.298436E+09 | 0.00 | 0.00 |
| May | 0.105291E+10 | 21206474.73 | 0.402059E+09 | 69409672.45 | 0.332649E+09 | 0.00 | 0.00 |
| June | 0.114507E+10 | 2678850.02 | 0.408421E+09 | 77792724.31 | 0.330629E+09 | 0.00 | 0.00 |
| July | 0.129176E+10 | 620.35 | 0.387587E+09 | 63052300.38 | 0.324535E+09 | 0.00 | 0.00 |
| August | 0.128138E+10 | 0.00 | 0.380064E+09 | 64509394.95 | 0.315555E+09 | 0.00 | 0.00 |
| September | 0.981952E+09 | 7659948.94 | 0.342985E+09 | 59910463.48 | 0.283074E+09 | 0.00 | 0.00 |
| October | 0.749198E+09 | 44687105.46 | 0.314617E+09 | 56505650.12 | 0.258111E+09 | 0.00 | 0.00 |
| November | 0.489999E+09 | 0.152838E+09 | 0.261754E+09 | 47707055.92 | 0.214047E+09 | 0.00 | 0.00 |
| December | 0.321153E+09 | 0.309176E+09 | 0.231697E+09 | 38154565.76 | 0.193543E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.922992E+10 | 0.153463E+10 | 0.390923E+10 | 0.660894E+09 | 0.324833E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.296330E+09 | 0.00 | 0.231697E+09 | 38154565.76 | 0.193543E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.129176E+10 | 0.381635E+09 | 0.408421E+09 | 77792724.31 | 0.332649E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.674186E+09 | 0.455163E+09 | 0.500973E+09 | 0.212789E+09 | 0.288184E+09 | 0.00 | 0.00 |
| February | 0.646549E+09 | 0.354659E+09 | 0.444374E+09 | 0.164103E+09 | 0.280271E+09 | 0.00 | 0.00 |
| March | 0.712921E+09 | 0.311937E+09 | 0.440309E+09 | 0.111757E+09 | 0.328552E+09 | 0.00 | 0.00 |
| April | 0.760030E+09 | 0.215284E+09 | 0.411650E+09 | 83432756.07 | 0.328218E+09 | 0.00 | 0.00 |
| May | 0.911166E+09 | 82932588.74 | 0.409272E+09 | 73300381.90 | 0.335972E+09 | 0.00 | 0.00 |
| June | 0.914464E+09 | 38149797.04 | 0.381169E+09 | 64350916.61 | 0.316819E+09 | 0.00 | 0.00 |
| July | 0.104035E+10 | 6019479.90 | 0.379530E+09 | 59797486.46 | 0.319732E+09 | 0.00 | 0.00 |
| August | 0.112643E+10 | 4253638.38 | 0.412187E+09 | 77596858.33 | 0.334590E+09 | 0.00 | 0.00 |
| September | 0.102519E+10 | 53374349.13 | 0.453184E+09 | 0.120809E+09 | 0.332376E+09 | 0.00 | 0.00 |
| October | 0.102879E+10 | 0.149998E+09 | 0.529915E+09 | 0.197231E+09 | 0.332684E+09 | 0.00 | 0.00 |
| November | 0.872088E+09 | 0.277924E+09 | 0.523836E+09 | 0.229573E+09 | 0.294263E+09 | 0.00 | 0.00 |
| December | 0.690744E+09 | 0.410736E+09 | 0.482245E+09 | 0.211497E+09 | 0.270748E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.104029E+11 | 0.236043E+10 | 0.536864E+10 | 0.160624E+10 | 0.376241E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.646549E+09 | 4253638.38 | 0.379530E+09 | 59797486.46 | 0.270748E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.112643E+10 | 0.455163E+09 | 0.529915E+09 | 0.229573E+09 | 0.335972E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.281179E+09 | 0.362107E+09 | 0.248143E+09 | 40820540.90 | 0.207322E+09 | 0.00 | 0.00 |
| February | 0.337259E+09 | 0.265402E+09 | 0.249812E+09 | 35776585.37 | 0.214036E+09 | 0.00 | 0.00 |
| March | 0.511110E+09 | 0.210267E+09 | 0.311508E+09 | 39900049.84 | 0.271608E+09 | 0.00 | 0.00 |
| April | 0.717747E+09 | 0.112567E+09 | 0.354711E+09 | 56568587.44 | 0.298142E+09 | 0.00 | 0.00 |
| May | 0.106525E+10 | 20183722.73 | 0.410171E+09 | 76119145.00 | 0.334052E+09 | 0.00 | 0.00 |
| June | 0.113668E+10 | 2518604.35 | 0.404981E+09 | 74644431.13 | 0.330337E+09 | 0.00 | 0.00 |
| July | 0.129284E+10 | 0.00 | 0.387856E+09 | 63617875.78 | 0.324239E+09 | 0.00 | 0.00 |
| August | 0.128393E+10 | 0.00 | 0.380071E+09 | 65161381.89 | 0.314909E+09 | 0.00 | 0.00 |
| September | 0.977368E+09 | 6869115.37 | 0.340327E+09 | 57945438.24 | 0.282382E+09 | 0.00 | 0.00 |
| October | 0.747975E+09 | 40648231.16 | 0.315707E+09 | 57352389.30 | 0.258354E+09 | 0.00 | 0.00 |
| November | 0.473849E+09 | 0.142355E+09 | 0.259038E+09 | 45236885.89 | 0.213801E+09 | 0.00 | 0.00 |
| December | 0.294035E+09 | 0.294265E+09 | 0.225129E+09 | 32698437.17 | 0.192431E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.911922E+10 | 0.145718E+10 | 0.388745E+10 | 0.645842E+09 | 0.324161E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.281179E+09 | 0.00 | 0.225129E+09 | 32698437.17 | 0.192431E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.129284E+10 | 0.362107E+09 | 0.410171E+09 | 76119145.00 | 0.334052E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.120291E+09 | 0.235001E+09 | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.00 | 0.00 |
| February | 0.153034E+09 | 0.169875E+09 | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.00 | 0.00 |
| March | 0.245894E+09 | 0.133733E+09 | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.00 | 0.00 |
| April | 0.346448E+09 | 70139889.21 | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.00 | 0.00 |
| May | 0.548176E+09 | 12001066.70 | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.00 | 0.00 |
| June | 0.610252E+09 | 1435146.64 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
| July | 0.706091E+09 | 0.00 | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.00 | 0.00 |
| August | 0.687244E+09 | 0.00 | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.00 | 0.00 |
| September | 0.505505E+09 | 4058141.42 | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.00 | 0.00 |
| October | 0.369258E+09 | 24655419.22 | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.00 | 0.00 |
| November | 0.223496E+09 | 89657659.55 | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.00 | 0.00 |
| December | 0.134849E+09 | 0.187156E+09 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.465054E+10 | 0.927713E+09 | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.120291E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.706091E+09 | 0.235001E+09 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.120262E+09 | 0.234993E+09 | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.00 | 0.00 |
| February | 0.153013E+09 | 0.169864E+09 | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.00 | 0.00 |
| March | 0.245886E+09 | 0.133704E+09 | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.00 | 0.00 |
| April | 0.346420E+09 | 70133424.94 | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.00 | 0.00 |
| May | 0.548146E+09 | 11999832.23 | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.00 | 0.00 |
| June | 0.610246E+09 | 1434333.49 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
| July | 0.706082E+09 | 0.00 | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.00 | 0.00 |
| August | 0.687233E+09 | 0.00 | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.00 | 0.00 |
| September | 0.505497E+09 | 4057226.62 | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.00 | 0.00 |
| October | 0.369241E+09 | 24652250.11 | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.00 | 0.00 |
| November | 0.223480E+09 | 89647710.02 | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.00 | 0.00 |
| December | 0.134834E+09 | 0.187139E+09 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.465034E+10 | 0.927625E+09 | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.120262E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.706082E+09 | 0.234993E+09 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.547603E+09 | 0.221603E+09 | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.00 | 0.00 |
| February | 0.497168E+09 | 0.165685E+09 | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.00 | 0.00 |
| March | 0.495745E+09 | 0.134979E+09 | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.00 | 0.00 |
| April | 0.467401E+09 | 72011251.09 | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.00 | 0.00 |
| May | 0.545978E+09 | 12172415.81 | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.00 | 0.00 |
| June | 0.562181E+09 | 1179043.76 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| July | 0.685690E+09 | 0.00 | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.00 | 0.00 |
| August | 0.754982E+09 | 0.00 | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.00 | 0.00 |
| September | 0.731881E+09 | 4083125.58 | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.00 | 0.00 |
| October | 0.770444E+09 | 24039582.67 | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.00 | 0.00 |
| November | 0.694827E+09 | 87689700.37 | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.00 | 0.00 |
| December | 0.578022E+09 | 0.180203E+09 | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.733192E+10 | 0.903646E+09 | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.467401E+09 | 0.00 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.770444E+09 | 0.221603E+09 | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.546286E+09 | 0.223503E+09 | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.00 | 0.00 |
| February | 0.495927E+09 | 0.167501E+09 | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.00 | 0.00 |
| March | 0.494138E+09 | 0.137097E+09 | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.00 | 0.00 |
| April | 0.465077E+09 | 74168227.22 | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.00 | 0.00 |
| May | 0.541679E+09 | 13136285.84 | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.00 | 0.00 |
| June | 0.557357E+09 | 1366328.86 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| July | 0.680441E+09 | 0.00 | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.00 | 0.00 |
| August | 0.749950E+09 | 0.00 | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.00 | 0.00 |
| September | 0.727315E+09 | 4483598.46 | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.00 | 0.00 |
| October | 0.766866E+09 | 25708732.15 | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.00 | 0.00 |
| November | 0.692513E+09 | 90252440.39 | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.00 | 0.00 |
| December | 0.576475E+09 | 0.182564E+09 | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.729402E+10 | 0.919781E+09 | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.465077E+09 | 0.00 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.766866E+09 | 0.223503E+09 | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.717757E+09 | 0.364484E+09 | 0.498811E+09 | 0.210162E+09 | 0.288649E+09 | 0.00 | 0.00 |
| February | 0.694602E+09 | 0.272677E+09 | 0.448527E+09 | 0.167433E+09 | 0.281094E+09 | 0.00 | 0.00 |
| March | 0.792395E+09 | 0.223005E+09 | 0.457065E+09 | 0.125013E+09 | 0.332052E+09 | 0.00 | 0.00 |
| April | 0.834167E+09 | 0.119651E+09 | 0.408771E+09 | 80259925.74 | 0.328511E+09 | 0.00 | 0.00 |
| May | 0.105991E+10 | 19799075.06 | 0.401160E+09 | 66590909.35 | 0.334569E+09 | 0.00 | 0.00 |
| June | 0.111462E+10 | 1792765.26 | 0.384610E+09 | 67499209.79 | 0.317111E+09 | 0.00 | 0.00 |
| July | 0.129641E+10 | 0.00 | 0.379261E+09 | 59231911.06 | 0.320029E+09 | 0.00 | 0.00 |
| August | 0.138054E+10 | 0.00 | 0.412180E+09 | 76944871.39 | 0.335235E+09 | 0.00 | 0.00 |
| September | 0.123355E+10 | 5568369.48 | 0.455842E+09 | 0.122774E+09 | 0.333068E+09 | 0.00 | 0.00 |
| October | 0.116653E+10 | 34591778.13 | 0.528826E+09 | 0.196384E+09 | 0.332442E+09 | 0.00 | 0.00 |
| November | 0.965379E+09 | 0.136345E+09 | 0.526552E+09 | 0.232043E+09 | 0.294509E+09 | 0.00 | 0.00 |
| December | 0.761160E+09 | 0.291598E+09 | 0.488813E+09 | 0.216953E+09 | 0.271860E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120170E+11 | 0.146951E+10 | 0.539042E+10 | 0.162129E+10 | 0.376913E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.694602E+09 | 0.00 | 0.379261E+09 | 59231911.06 | 0.271860E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.138054E+10 | 0.364484E+09 | 0.528826E+09 | 0.232043E+09 | 0.335235E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.298375E+09 | 0.375127E+09 | 0.245981E+09 | 38193560.46 | 0.207788E+09 | 0.00 | 0.00 |
| February | 0.354853E+09 | 0.274842E+09 | 0.253965E+09 | 39106376.58 | 0.214858E+09 | 0.00 | 0.00 |
| March | 0.545736E+09 | 0.221260E+09 | 0.328264E+09 | 53156512.56 | 0.275108E+09 | 0.00 | 0.00 |
| April | 0.715044E+09 | 0.117743E+09 | 0.351832E+09 | 53395757.12 | 0.298436E+09 | 0.00 | 0.00 |
| May | 0.106192E+10 | 19541122.55 | 0.402059E+09 | 69409672.45 | 0.332649E+09 | 0.00 | 0.00 |
| June | 0.116152E+10 | 2045438.92 | 0.408421E+09 | 77792724.31 | 0.330629E+09 | 0.00 | 0.00 |
| July | 0.131695E+10 | 0.00 | 0.387587E+09 | 63052300.38 | 0.324535E+09 | 0.00 | 0.00 |
| August | 0.131401E+10 | 0.00 | 0.380064E+09 | 64509394.95 | 0.315555E+09 | 0.00 | 0.00 |
| September | 0.101084E+10 | 5539741.73 | 0.342985E+09 | 59910463.48 | 0.283074E+09 | 0.00 | 0.00 |
| October | 0.771634E+09 | 35404307.22 | 0.314617E+09 | 56505650.12 | 0.258111E+09 | 0.00 | 0.00 |
| November | 0.502218E+09 | 0.139142E+09 | 0.261754E+09 | 47707055.92 | 0.214047E+09 | 0.00 | 0.00 |
| December | 0.326068E+09 | 0.298475E+09 | 0.231697E+09 | 38154565.76 | 0.193543E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.937916E+10 | 0.148912E+10 | 0.390923E+10 | 0.660894E+09 | 0.324833E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.298375E+09 | 0.00 | 0.231697E+09 | 38154565.76 | 0.193543E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.131695E+10 | 0.375127E+09 | 0.408421E+09 | 77792724.31 | 0.332649E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.714099E+09 | 0.356041E+09 | 0.500973E+09 | 0.212789E+09 | 0.288184E+09 | 0.00 | 0.00 |
| February | 0.680660E+09 | 0.265437E+09 | 0.444374E+09 | 0.164103E+09 | 0.280271E+09 | 0.00 | 0.00 |
| March | 0.756406E+09 | 0.214291E+09 | 0.440309E+09 | 0.111757E+09 | 0.328552E+09 | 0.00 | 0.00 |
| April | 0.835136E+09 | 0.113198E+09 | 0.411650E+09 | 83432756.07 | 0.328218E+09 | 0.00 | 0.00 |
| May | 0.107128E+10 | 17837481.34 | 0.409272E+09 | 73300381.90 | 0.335972E+09 | 0.00 | 0.00 |
| June | 0.110570E+10 | 1556464.42 | 0.381169E+09 | 64350916.61 | 0.316819E+09 | 0.00 | 0.00 |
| July | 0.129743E+10 | 0.00 | 0.379530E+09 | 59797486.46 | 0.319732E+09 | 0.00 | 0.00 |
| August | 0.138328E+10 | 0.00 | 0.412187E+09 | 77596858.33 | 0.334590E+09 | 0.00 | 0.00 |
| September | 0.122929E+10 | 4995707.38 | 0.453184E+09 | 0.120809E+09 | 0.332376E+09 | 0.00 | 0.00 |
| October | 0.116736E+10 | 32418560.19 | 0.529915E+09 | 0.197231E+09 | 0.332684E+09 | 0.00 | 0.00 |
| November | 0.956636E+09 | 0.133229E+09 | 0.523836E+09 | 0.229573E+09 | 0.294263E+09 | 0.00 | 0.00 |
| December | 0.744420E+09 | 0.286906E+09 | 0.482245E+09 | 0.211497E+09 | 0.270748E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119417E+11 | 0.142591E+10 | 0.536864E+10 | 0.160624E+10 | 0.376241E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.680660E+09 | 0.00 | 0.379530E+09 | 59797486.46 | 0.270748E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.138328E+10 | 0.356041E+09 | 0.529915E+09 | 0.229573E+09 | 0.335972E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.283389E+09 | 0.355926E+09 | 0.248143E+09 | 40820540.90 | 0.207322E+09 | 0.00 | 0.00 |
| February | 0.336866E+09 | 0.263719E+09 | 0.249812E+09 | 35776585.37 | 0.214036E+09 | 0.00 | 0.00 |
| March | 0.508584E+09 | 0.211391E+09 | 0.311508E+09 | 39900049.84 | 0.271608E+09 | 0.00 | 0.00 |
| April | 0.716857E+09 | 0.112157E+09 | 0.354711E+09 | 56568587.44 | 0.298142E+09 | 0.00 | 0.00 |
| May | 0.107425E+10 | 18495171.92 | 0.410171E+09 | 76119145.00 | 0.334052E+09 | 0.00 | 0.00 |
| June | 0.115271E+10 | 1876170.97 | 0.404981E+09 | 74644431.13 | 0.330337E+09 | 0.00 | 0.00 |
| July | 0.131800E+10 | 0.00 | 0.387856E+09 | 63617875.78 | 0.324239E+09 | 0.00 | 0.00 |
| August | 0.131678E+10 | 0.00 | 0.380071E+09 | 65161381.89 | 0.314909E+09 | 0.00 | 0.00 |
| September | 0.100651E+10 | 4923141.36 | 0.340327E+09 | 57945438.24 | 0.282382E+09 | 0.00 | 0.00 |
| October | 0.771062E+09 | 31878395.10 | 0.315707E+09 | 57352389.30 | 0.258354E+09 | 0.00 | 0.00 |
| November | 0.486754E+09 | 0.129360E+09 | 0.259038E+09 | 45236885.89 | 0.213801E+09 | 0.00 | 0.00 |
| December | 0.299389E+09 | 0.283962E+09 | 0.225129E+09 | 32698437.17 | 0.192431E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.927116E+10 | 0.141369E+10 | 0.388745E+10 | 0.645842E+09 | 0.324161E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.283389E+09 | 0.00 | 0.225129E+09 | 32698437.17 | 0.192431E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.131800E+10 | 0.355926E+09 | 0.410171E+09 | 76119145.00 | 0.334052E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.120897E+09 | 0.233178E+09 | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.00 | 0.00 |
| February | 0.152976E+09 | 0.169363E+09 | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.00 | 0.00 |
| March | 0.245342E+09 | 0.133938E+09 | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.00 | 0.00 |
| April | 0.347172E+09 | 69515483.10 | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.00 | 0.00 |
| May | 0.554385E+09 | 11051794.21 | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.00 | 0.00 |
| June | 0.619916E+09 | 1118986.45 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
| July | 0.720194E+09 | 0.00 | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.00 | 0.00 |
| August | 0.704670E+09 | 0.00 | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.00 | 0.00 |
| September | 0.520784E+09 | 3074768.11 | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.00 | 0.00 |
| October | 0.381122E+09 | 20357558.05 | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.00 | 0.00 |
| November | 0.229866E+09 | 83344941.69 | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.00 | 0.00 |
| December | 0.137075E+09 | 0.182645E+09 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.473440E+10 | 0.907589E+09 | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.120897E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.720194E+09 | 0.233178E+09 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.120858E+09 | 0.233173E+09 | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.00 | 0.00 |
| February | 0.152952E+09 | 0.169351E+09 | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.00 | 0.00 |
| March | 0.245329E+09 | 0.133914E+09 | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.00 | 0.00 |
| April | 0.347146E+09 | 69506068.13 | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.00 | 0.00 |
| May | 0.554361E+09 | 11049265.09 | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.00 | 0.00 |
| June | 0.619909E+09 | 1118175.82 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
| July | 0.720187E+09 | 0.00 | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.00 | 0.00 |
| August | 0.704660E+09 | 0.00 | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.00 | 0.00 |
| September | 0.520776E+09 | 3073773.38 | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.00 | 0.00 |
| October | 0.381105E+09 | 20353421.09 | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.00 | 0.00 |
| November | 0.229848E+09 | 83334000.18 | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.00 | 0.00 |
| December | 0.137055E+09 | 0.182629E+09 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.473419E+10 | 0.907502E+09 | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.120858E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.720187E+09 | 0.233173E+09 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.546212E+09 | 0.219234E+09 | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.00 | 0.00 |
| February | 0.495444E+09 | 0.164367E+09 | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.00 | 0.00 |
| March | 0.494137E+09 | 0.134409E+09 | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.00 | 0.00 |
| April | 0.467316E+09 | 70951532.49 | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.00 | 0.00 |
| May | 0.552135E+09 | 11082452.10 | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.00 | 0.00 |
| June | 0.572478E+09 | 859702.93 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| July | 0.699396E+09 | 0.00 | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.00 | 0.00 |
| August | 0.771881E+09 | 0.00 | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.00 | 0.00 |
| September | 0.745684E+09 | 3029649.10 | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.00 | 0.00 |
| October | 0.780087E+09 | 19310231.87 | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.00 | 0.00 |
| November | 0.698773E+09 | 80656667.32 | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.00 | 0.00 |
| December | 0.578480E+09 | 0.175286E+09 | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.740202E+10 | 0.879186E+09 | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.467316E+09 | 0.00 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.780087E+09 | 0.219234E+09 | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.546186E+09 | 0.219224E+09 | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.00 | 0.00 |
| February | 0.495425E+09 | 0.164354E+09 | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.00 | 0.00 |
| March | 0.494125E+09 | 0.134386E+09 | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.00 | 0.00 |
| April | 0.467291E+09 | 70941822.59 | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.00 | 0.00 |
| May | 0.552110E+09 | 11079931.10 | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.00 | 0.00 |
| June | 0.572471E+09 | 858997.38 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| July | 0.699388E+09 | 0.00 | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.00 | 0.00 |
| August | 0.771872E+09 | 0.00 | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.00 | 0.00 |
| September | 0.745677E+09 | 3028721.60 | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.00 | 0.00 |
| October | 0.780073E+09 | 19306135.07 | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.00 | 0.00 |
| November | 0.698758E+09 | 80645402.56 | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.00 | 0.00 |
| December | 0.578465E+09 | 0.175271E+09 | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.740184E+10 | 0.879095E+09 | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.467291E+09 | 0.00 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.780073E+09 | 0.219224E+09 | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.721978E+09 | 0.329538E+09 | 0.498811E+09 | 0.210162E+09 | 0.288649E+09 | 0.00 | 0.00 |
| February | 0.690810E+09 | 0.250314E+09 | 0.448527E+09 | 0.167433E+09 | 0.281094E+09 | 0.00 | 0.00 |
| March | 0.780856E+09 | 0.208643E+09 | 0.457065E+09 | 0.125013E+09 | 0.332052E+09 | 0.00 | 0.00 |
| April | 0.815850E+09 | 0.113714E+09 | 0.408771E+09 | 80259925.74 | 0.328511E+09 | 0.00 | 0.00 |
| May | 0.103276E+10 | 18346459.30 | 0.401160E+09 | 66590909.35 | 0.334569E+09 | 0.00 | 0.00 |
| June | 0.108652E+10 | 1577072.47 | 0.384610E+09 | 67499209.79 | 0.317111E+09 | 0.00 | 0.00 |
| July | 0.126202E+10 | 0.00 | 0.379261E+09 | 59231911.06 | 0.320029E+09 | 0.00 | 0.00 |
| August | 0.134576E+10 | 0.00 | 0.412180E+09 | 76944871.39 | 0.335235E+09 | 0.00 | 0.00 |
| September | 0.120602E+10 | 4978562.71 | 0.455842E+09 | 0.122774E+09 | 0.333068E+09 | 0.00 | 0.00 |
| October | 0.114362E+10 | 31463104.47 | 0.528826E+09 | 0.196384E+09 | 0.332442E+09 | 0.00 | 0.00 |
| November | 0.950647E+09 | 0.128634E+09 | 0.526552E+09 | 0.232043E+09 | 0.294509E+09 | 0.00 | 0.00 |
| December | 0.758179E+09 | 0.270254E+09 | 0.488813E+09 | 0.216953E+09 | 0.271860E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.117950E+11 | 0.135746E+10 | 0.539042E+10 | 0.162129E+10 | 0.376913E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.690810E+09 | 0.00 | 0.379261E+09 | 59231911.06 | 0.271860E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.134576E+10 | 0.329538E+09 | 0.528826E+09 | 0.232043E+09 | 0.335235E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.307153E+09 | 0.332339E+09 | 0.245981E+09 | 38193560.46 | 0.207788E+09 | 0.00 | 0.00 |
| February | 0.355348E+09 | 0.249794E+09 | 0.253965E+09 | 39106376.58 | 0.214858E+09 | 0.00 | 0.00 |
| March | 0.537229E+09 | 0.206499E+09 | 0.328264E+09 | 53156512.56 | 0.275108E+09 | 0.00 | 0.00 |
| April | 0.698312E+09 | 0.112274E+09 | 0.351832E+09 | 53395757.12 | 0.298436E+09 | 0.00 | 0.00 |
| May | 0.103470E+10 | 18294488.42 | 0.402059E+09 | 69409672.45 | 0.332649E+09 | 0.00 | 0.00 |
| June | 0.113266E+10 | 1844280.68 | 0.408421E+09 | 77792724.31 | 0.330629E+09 | 0.00 | 0.00 |
| July | 0.128246E+10 | 0.00 | 0.387587E+09 | 63052300.38 | 0.324535E+09 | 0.00 | 0.00 |
| August | 0.127977E+10 | 0.00 | 0.380064E+09 | 64509394.95 | 0.315555E+09 | 0.00 | 0.00 |
| September | 0.985282E+09 | 5061108.63 | 0.342985E+09 | 59910463.48 | 0.283074E+09 | 0.00 | 0.00 |
| October | 0.752717E+09 | 32841476.45 | 0.314617E+09 | 56505650.12 | 0.258111E+09 | 0.00 | 0.00 |
| November | 0.492428E+09 | 0.131258E+09 | 0.261754E+09 | 47707055.92 | 0.214047E+09 | 0.00 | 0.00 |
| December | 0.327602E+09 | 0.272465E+09 | 0.231697E+09 | 38154565.76 | 0.193543E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.918567E+10 | 0.136267E+10 | 0.390923E+10 | 0.660894E+09 | 0.324833E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.307153E+09 | 0.00 | 0.231697E+09 | 38154565.76 | 0.193543E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.128246E+10 | 0.332339E+09 | 0.408421E+09 | 77792724.31 | 0.332649E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.719379E+09 | 0.323368E+09 | 0.500973E+09 | 0.212789E+09 | 0.288184E+09 | 0.00 | 0.00 |
| February | 0.678023E+09 | 0.244571E+09 | 0.444374E+09 | 0.164103E+09 | 0.280271E+09 | 0.00 | 0.00 |
| March | 0.746177E+09 | 0.200995E+09 | 0.440309E+09 | 0.111757E+09 | 0.328552E+09 | 0.00 | 0.00 |
| April | 0.817290E+09 | 0.107621E+09 | 0.411650E+09 | 83432756.07 | 0.328218E+09 | 0.00 | 0.00 |
| May | 0.104416E+10 | 16513462.83 | 0.409272E+09 | 73300381.90 | 0.335972E+09 | 0.00 | 0.00 |
| June | 0.107742E+10 | 1347279.36 | 0.381169E+09 | 64350916.61 | 0.316819E+09 | 0.00 | 0.00 |
| July | 0.126303E+10 | 0.00 | 0.379530E+09 | 59797486.46 | 0.319732E+09 | 0.00 | 0.00 |
| August | 0.134862E+10 | 0.00 | 0.412187E+09 | 77596858.33 | 0.334590E+09 | 0.00 | 0.00 |
| September | 0.120189E+10 | 4452242.72 | 0.453184E+09 | 0.120809E+09 | 0.332376E+09 | 0.00 | 0.00 |
| October | 0.114449E+10 | 29317780.19 | 0.529915E+09 | 0.197231E+09 | 0.332684E+09 | 0.00 | 0.00 |
| November | 0.942111E+09 | 0.125755E+09 | 0.523836E+09 | 0.229573E+09 | 0.294263E+09 | 0.00 | 0.00 |
| December | 0.742002E+09 | 0.266359E+09 | 0.482245E+09 | 0.211497E+09 | 0.270748E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.117246E+11 | 0.132030E+10 | 0.536864E+10 | 0.160624E+10 | 0.376241E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.678023E+09 | 0.00 | 0.379530E+09 | 59797486.46 | 0.270748E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.134862E+10 | 0.323368E+09 | 0.529915E+09 | 0.229573E+09 | 0.335972E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.296053E+09 | 0.318341E+09 | 0.248143E+09 | 40820540.90 | 0.207322E+09 | 0.00 | 0.00 |
| February | 0.339360E+09 | 0.241207E+09 | 0.249812E+09 | 35776585.37 | 0.214036E+09 | 0.00 | 0.00 |
| March | 0.501518E+09 | 0.197885E+09 | 0.311508E+09 | 39900049.84 | 0.271608E+09 | 0.00 | 0.00 |
| April | 0.700535E+09 | 0.106985E+09 | 0.354711E+09 | 56568587.44 | 0.298142E+09 | 0.00 | 0.00 |
| May | 0.104698E+10 | 17260935.01 | 0.410171E+09 | 76119145.00 | 0.334052E+09 | 0.00 | 0.00 |
| June | 0.112374E+10 | 1671530.05 | 0.404981E+09 | 74644431.13 | 0.330337E+09 | 0.00 | 0.00 |
| July | 0.128355E+10 | 0.00 | 0.387856E+09 | 63617875.78 | 0.324239E+09 | 0.00 | 0.00 |
| August | 0.128271E+10 | 0.00 | 0.380071E+09 | 65161381.89 | 0.314909E+09 | 0.00 | 0.00 |
| September | 0.981098E+09 | 4488303.02 | 0.340327E+09 | 57945438.24 | 0.282382E+09 | 0.00 | 0.00 |
| October | 0.752259E+09 | 29445341.89 | 0.315707E+09 | 57352389.30 | 0.258354E+09 | 0.00 | 0.00 |
| November | 0.477735E+09 | 0.122400E+09 | 0.259038E+09 | 45236885.89 | 0.213801E+09 | 0.00 | 0.00 |
| December | 0.303402E+09 | 0.260881E+09 | 0.225129E+09 | 32698437.17 | 0.192431E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.908895E+10 | 0.130056E+10 | 0.388745E+10 | 0.645842E+09 | 0.324161E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.296053E+09 | 0.00 | 0.225129E+09 | 32698437.17 | 0.192431E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.128355E+10 | 0.318341E+09 | 0.410171E+09 | 76119145.00 | 0.334052E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.125986E+09 | 0.211579E+09 | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.00 | 0.00 |
| February | 0.153518E+09 | 0.157849E+09 | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.00 | 0.00 |
| March | 0.241469E+09 | 0.127363E+09 | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.00 | 0.00 |
| April | 0.338996E+09 | 67274900.97 | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.00 | 0.00 |
| May | 0.540381E+09 | 10640415.60 | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.00 | 0.00 |
| June | 0.604782E+09 | 1064922.41 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
| July | 0.702077E+09 | 0.00 | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.00 | 0.00 |
| August | 0.686827E+09 | 0.00 | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.00 | 0.00 |
| September | 0.507706E+09 | 2905204.62 | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.00 | 0.00 |
| October | 0.371835E+09 | 19298718.84 | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.00 | 0.00 |
| November | 0.225420E+09 | 79730165.91 | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.00 | 0.00 |
| December | 0.138108E+09 | 0.170548E+09 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.463711E+10 | 0.848253E+09 | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.125986E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.702077E+09 | 0.211579E+09 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.125804E+09 | 0.211524E+09 | 0.113285E+09 | 0.00 | 0.113285E+09 | 0.00 | 0.00 |
| February | 0.153409E+09 | 0.157793E+09 | 0.117290E+09 | 0.00 | 0.117290E+09 | 0.00 | 0.00 |
| March | 0.241408E+09 | 0.127295E+09 | 0.149187E+09 | 6473.38 | 0.149181E+09 | 0.00 | 0.00 |
| April | 0.338936E+09 | 67242543.95 | 0.162903E+09 | 469952.51 | 0.162433E+09 | 0.00 | 0.00 |
| May | 0.540342E+09 | 10633239.05 | 0.189642E+09 | 5988921.70 | 0.183653E+09 | 0.00 | 0.00 |
| June | 0.604771E+09 | 1063484.22 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
| July | 0.702066E+09 | 0.00 | 0.185835E+09 | 5293062.55 | 0.180542E+09 | 0.00 | 0.00 |
| August | 0.686814E+09 | 0.00 | 0.173500E+09 | 1872724.47 | 0.171627E+09 | 0.00 | 0.00 |
| September | 0.507692E+09 | 2903375.13 | 0.152538E+09 | 37970.62 | 0.152500E+09 | 0.00 | 0.00 |
| October | 0.371804E+09 | 19288945.10 | 0.139699E+09 | 0.00 | 0.139699E+09 | 0.00 | 0.00 |
| November | 0.225369E+09 | 79698554.06 | 0.116060E+09 | 0.00 | 0.116060E+09 | 0.00 | 0.00 |
| December | 0.138008E+09 | 0.170490E+09 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.463642E+10 | 0.847932E+09 | 0.180131E+10 | 24264581.43 | 0.177705E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.125804E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.105737E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.702066E+09 | 0.211524E+09 | 0.195639E+09 | 10595476.20 | 0.185043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.548042E+09 | 0.203756E+09 | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.00 | 0.00 |
| February | 0.493014E+09 | 0.154741E+09 | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.00 | 0.00 |
| March | 0.488193E+09 | 0.128106E+09 | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.00 | 0.00 |
| April | 0.458025E+09 | 68390491.43 | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.00 | 0.00 |
| May | 0.538188E+09 | 10518630.33 | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.00 | 0.00 |
| June | 0.557918E+09 | 787030.02 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| July | 0.681285E+09 | 0.00 | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.00 | 0.00 |
| August | 0.753664E+09 | 0.00 | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.00 | 0.00 |
| September | 0.731223E+09 | 2790559.89 | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.00 | 0.00 |
| October | 0.768015E+09 | 17874367.26 | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.00 | 0.00 |
| November | 0.690831E+09 | 77093266.68 | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.00 | 0.00 |
| December | 0.576381E+09 | 0.166126E+09 | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.728478E+10 | 0.830182E+09 | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.458025E+09 | 0.00 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.768015E+09 | 0.203756E+09 | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.547921E+09 | 0.203702E+09 | 0.366115E+09 | 0.171968E+09 | 0.194147E+09 | 0.00 | 0.00 |
| February | 0.492938E+09 | 0.154688E+09 | 0.311852E+09 | 0.128327E+09 | 0.183525E+09 | 0.00 | 0.00 |
| March | 0.488140E+09 | 0.128043E+09 | 0.277989E+09 | 71863315.68 | 0.206125E+09 | 0.00 | 0.00 |
| April | 0.457968E+09 | 68357913.35 | 0.219842E+09 | 27334121.13 | 0.192508E+09 | 0.00 | 0.00 |
| May | 0.538148E+09 | 10511731.83 | 0.188743E+09 | 3170158.59 | 0.185573E+09 | 0.00 | 0.00 |
| June | 0.557905E+09 | 785778.92 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| July | 0.681272E+09 | 0.00 | 0.177508E+09 | 1472673.23 | 0.176036E+09 | 0.00 | 0.00 |
| August | 0.753650E+09 | 0.00 | 0.205616E+09 | 14308200.91 | 0.191307E+09 | 0.00 | 0.00 |
| September | 0.731211E+09 | 2789005.96 | 0.265396E+09 | 62901437.47 | 0.202494E+09 | 0.00 | 0.00 |
| October | 0.767988E+09 | 17865238.74 | 0.353907E+09 | 0.139878E+09 | 0.214029E+09 | 0.00 | 0.00 |
| November | 0.690789E+09 | 77061657.61 | 0.380858E+09 | 0.184336E+09 | 0.196522E+09 | 0.00 | 0.00 |
| December | 0.576316E+09 | 0.166074E+09 | 0.362852E+09 | 0.178798E+09 | 0.184054E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.728424E+10 | 0.829878E+09 | 0.328251E+10 | 0.984660E+09 | 0.229785E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.457968E+09 | 0.00 | 0.171827E+09 | 301961.68 | 0.171525E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.767988E+09 | 0.203702E+09 | 0.380858E+09 | 0.184336E+09 | 0.214029E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 40717049.59 | 36311584.02 | 32359668.68 | 9795054.94 | 22564613.74 | 0.00 | 0.00 |
| February | 43558030.57 | 28004683.86 | 31799209.08 | 8584737.28 | 23214471.79 | 0.00 | 0.00 |
| March | 60573276.68 | 23600511.18 | 38949495.85 | 9572626.05 | 29376869.79 | 0.00 | 0.00 |
| April | 83928430.55 | 14025358.50 | 46025197.84 | 13461095.80 | 32564102.05 | 0.00 | 0.00 |
| May | 0.115630E+09 | 3156452.78 | 52916859.73 | 16828032.54 | 36088827.19 | 0.00 | 0.00 |
| June | 0.117596E+09 | 625990.51 | 50232589.73 | 15368807.44 | 34863782.29 | 0.00 | 0.00 |
| July | 0.131204E+09 | 3780.19 | 48475879.46 | 13995276.34 | 34480603.12 | 0.00 | 0.00 |
| August | 0.134459E+09 | 0.00 | 49567553.04 | 15186370.96 | 34381182.08 | 0.00 | 0.00 |
| September | 0.106299E+09 | 1002462.47 | 45060655.36 | 13895132.56 | 31165522.80 | 0.00 | 0.00 |
| October | 86088116.67 | 5149147.66 | 42233706.50 | 13761939.26 | 28471767.24 | 0.00 | 0.00 |
| November | 58425995.73 | 16036038.42 | 34308033.15 | 10854774.90 | 23453258.25 | 0.00 | 0.00 |
| December | 38666191.62 | 30657257.28 | 28648719.70 | 7846123.10 | 20802596.60 | 0.00 | 0.00 |
| Annual Sum or Average | 0.101715E+10 | 0.158573E+09 | 0.500578E+09 | 0.149150E+09 | 0.351428E+09 | 0.00 | 0.00 |
| Minimum of Months | 38666191.62 | 0.00 | 28648719.70 | 7846123.10 | 20802596.60 | 0.00 | 0.00 |
| Maximum of Months | 0.134459E+09 | 36311584.02 | 52916859.73 | 16828032.54 | 36088827.19 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.116169E+09 | 0.116705E+09 | 96375146.46 | 29172111.25 | 67203035.21 | 0.00 | 0.00 |
| February | 0.126700E+09 | 89041892.69 | 94705958.29 | 25567484.06 | 69138474.23 | 0.00 | 0.00 |
| March | 0.177320E+09 | 75369069.86 | 0.116001E+09 | 28509662.66 | 87491629.07 | 0.00 | 0.00 |
| April | 0.244485E+09 | 47644083.70 | 0.137074E+09 | 40090493.25 | 96983999.91 | 0.00 | 0.00 |
| May | 0.328776E+09 | 14271266.68 | 0.157600E+09 | 50118068.79 | 0.107482E+09 | 0.00 | 0.00 |
| June | 0.329715E+09 | 4991888.85 | 0.149605E+09 | 45772133.29 | 0.103833E+09 | 0.00 | 0.00 |
| July | 0.362560E+09 | 276412.70 | 0.144373E+09 | 41681415.86 | 0.102692E+09 | 0.00 | 0.00 |
| August | 0.369289E+09 | 149722.58 | 0.147625E+09 | 45228792.04 | 0.102396E+09 | 0.00 | 0.00 |
| September | 0.292751E+09 | 6835786.69 | 0.134202E+09 | 41383162.75 | 92818682.85 | 0.00 | 0.00 |
| October | 0.240851E+09 | 25888682.20 | 0.125782E+09 | 40986479.96 | 84796008.42 | 0.00 | 0.00 |
| November | 0.165851E+09 | 59867838.48 | 0.102178E+09 | 32328221.01 | 69849639.73 | 0.00 | 0.00 |
| December | 0.109964E+09 | 0.100891E+09 | 85323016.88 | 23367707.19 | 61955309.69 | 0.00 | 0.00 |
| Annual Sum or Average | 0.286443E+10 | 0.541933E+09 | 0.149084E+10 | 0.444206E+09 | 0.104664E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.109964E+09 | 149722.58 | 85323016.88 | 23367707.19 | 61955309.69 | 0.00 | 0.00 |
| Maximum of Months | 0.369289E+09 | 0.116705E+09 | 0.157600E+09 | 50118068.79 | 0.107482E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 37915250.89 | 40000530.83 | 32359668.68 | 9795054.94 | 22564613.74 | 0.00 | 0.00 |
| February | 41998049.68 | 30280770.27 | 31799209.08 | 8584737.28 | 23214471.79 | 0.00 | 0.00 |
| March | 59975856.27 | 25081654.22 | 38949495.85 | 9572626.05 | 29376869.79 | 0.00 | 0.00 |
| April | 84642120.37 | 14559253.49 | 46025197.84 | 13461095.80 | 32564102.05 | 0.00 | 0.00 |
| May | 0.118342E+09 | 3278708.57 | 52916859.73 | 16828032.54 | 36088827.19 | 0.00 | 0.00 |
| June | 0.120778E+09 | 665647.72 | 50232589.73 | 15368807.44 | 34863782.29 | 0.00 | 0.00 |
| July | 0.135626E+09 | 5054.67 | 48475879.46 | 13995276.34 | 34480603.12 | 0.00 | 0.00 |
| August | 0.138922E+09 | 0.00 | 49567553.04 | 15186370.96 | 34381182.08 | 0.00 | 0.00 |
| September | 0.109184E+09 | 1082453.50 | 45060655.36 | 13895132.56 | 31165522.80 | 0.00 | 0.00 |
| October | 87668392.40 | 5503646.48 | 42233706.50 | 13761939.26 | 28471767.24 | 0.00 | 0.00 |
| November | 58400324.69 | 16934679.60 | 34308033.15 | 10854774.90 | 23453258.25 | 0.00 | 0.00 |
| December | 37018589.29 | 33085120.34 | 28648719.70 | 7846123.10 | 20802596.60 | 0.00 | 0.00 |
| Annual Sum or Average | 0.103047E+10 | 0.170478E+09 | 0.500578E+09 | 0.149150E+09 | 0.351428E+09 | 0.00 | 0.00 |
| Minimum of Months | 37018589.29 | 0.00 | 28648719.70 | 7846123.10 | 20802596.60 | 0.00 | 0.00 |
| Maximum of Months | 0.138922E+09 | 40000530.83 | 52916859.73 | 16828032.54 | 36088827.19 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 19.24 | 14.74 | 11.63 | 2.95 | 7.91 | 83.00 | 101.34 | 0.00 |
| February | 20.75 | 16.26 | 13.46 | 3.66 | 9.80 | 96.50 | 106.33 | 0.00 |
| March | 23.12 | 16.75 | 12.67 | 3.48 | 11.63 | 114.51 | 110.36 | 0.00 |
| April | 26.49 | 19.17 | 14.91 | 3.36 | 14.65 | 129.52 | 127.73 | 0.00 |
| May | 31.37 | 21.91 | 17.14 | 3.30 | 19.37 | 135.62 | 152.47 | 0.00 |
| June | 32.97 | 24.78 | 21.39 | 3.95 | 20.59 | 135.23 | 162.31 | 0.00 |
| July | 35.08 | 26.48 | 23.16 | 3.85 | 24.14 | 131.49 | 150.69 | 0.00 |
| August | 35.31 | 27.02 | 24.10 | 3.89 | 24.33 | 129.32 | 147.63 | 0.00 |
| September | 32.49 | 25.68 | 23.13 | 3.64 | 20.59 | 118.70 | 140.92 | 0.00 |
| October | 29.53 | 22.66 | 19.34 | 3.16 | 16.84 | 101.82 | 135.23 | 0.00 |
| November | 25.53 | 19.62 | 16.50 | 2.98 | 12.88 | 85.82 | 121.41 | 0.00 |
| December | 21.13 | 16.84 | 14.23 | 2.84 | 10.14 | 76.46 | 98.30 | 0.00 |
| Annual Sum or Average | 27.79 | 21.02 | 17.66 | 3.42 | 16.11 | 111.56 | 129.66 | 0.00 |
| Minimum of Months | 19.24 | 14.74 | 11.63 | 2.84 | 7.91 | 76.46 | 98.30 | 0.00 |
| Maximum of Months | 35.31 | 27.02 | 24.10 | 3.95 | 24.33 | 135.62 | 162.31 | 0.00 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 28.00 | 23-JAN-13:00 | 16.55 | 9.00 | 4.60 | 16.85 | 268.00 | 249.50 |
| February | 32.50 | 06-FEB-14:00 | 17.28 | 6.50 | 6.20 | 21.27 | 242.00 | 327.50 |
| March | 38.00 | 27-MAR-10:00 | 18.84 | 6.00 | 7.70 | 21.44 | 329.50 | 440.00 |
| April | 42.00 | 28-APR-11:00 | 19.18 | 2.00 | 2.60 | 24.16 | 371.50 | 432.50 |
| May | 42.10 | 31-MAY-18:00 | 20.76 | 8.00 | 5.10 | 30.18 | 0.00 | 0.00 |
| June | 43.00 | 12-JUN-11:00 | 24.56 | 17.00 | 3.60 | 28.91 | 372.00 | 427.00 |
| July | 46.00 | 21-JUL-11:00 | 22.01 | 9.00 | 3.60 | 32.99 | 306.00 | 562.50 |
| August | 46.00 | 16-AUG-11:00 | 25.38 | 17.00 | 7.20 | 31.75 | 273.00 | 629.50 |
| September | 41.20 | 26-SEP-12:00 | 22.43 | 13.00 | 4.10 | 26.15 | 325.00 | 455.00 |
| October | 38.00 | 04-OCT-11:00 | 19.81 | 9.00 | 1.00 | 22.13 | 338.00 | 421.50 |
| November | 34.00 | 05-NOV-11:00 | 17.15 | 5.00 | 2.10 | 17.39 | 294.00 | 427.50 |
| December | 30.00 | 10-DEC-11:00 | 19.04 | 13.00 | 4.10 | 21.27 | 305.00 | 214.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 28.00 | 16.55 | 2.00 | 1.00 | 16.85 | 0.00 | 0.00 | |
| Maximum of Months | 46.00 | 25.38 | 17.00 | 7.70 | 32.99 | 372.00 | 629.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 12.00 | 09-JAN-07:00 | 12.00 | 12.00 | 1.00 | -1.9 | 54.50 | 10.00 |
| February | 13.00 | 01-FEB-04:00 | 12.45 | 12.00 | 1.00 | -0.8 | 0.00 | 0.00 |
| March | 14.00 | 07-MAR-05:00 | 11.74 | 10.00 | 0.50 | 2.64 | 0.00 | 0.00 |
| April | 17.00 | 01-APR-05:00 | 15.74 | 15.00 | 0.50 | 3.69 | 0.00 | 0.00 |
| May | 20.40 | 01-MAY-05:00 | 20.40 | 20.40 | 2.10 | 9.33 | 28.50 | 50.50 |
| June | 21.00 | 22-JUN-07:00 | 19.59 | 19.00 | 1.50 | 8.35 | 206.50 | 266.00 |
| July | 28.00 | 03-JUL-05:00 | 16.06 | 8.00 | 1.00 | 12.41 | 32.50 | 30.50 |
| August | 28.80 | 31-AUG-03:00 | 25.95 | 25.00 | 1.50 | 17.03 | 0.00 | 0.00 |
| September | 23.00 | 25-SEP-04:00 | 22.27 | 22.00 | 2.10 | 10.88 | 0.00 | 0.00 |
| October | 20.60 | 29-OCT-06:00 | 17.24 | 15.40 | 0.50 | 7.15 | 49.50 | 123.00 |
| November | 16.90 | 22-NOV-06:00 | 14.44 | 12.90 | 3.10 | 3.06 | 31.00 | 106.50 |
| December | 13.00 | 18-DEC-04:00 | 10.82 | 9.00 | 1.80 | -1.4 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 12.00 | 10.82 | 8.00 | 0.50 | -1.9 | 0.00 | 0.00 | |
| Maximum of Months | 28.80 | 25.95 | 25.00 | 3.10 | 17.03 | 206.50 | 266.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 20.89 | 30-JAN-13:00 | 23.00 | 20.00 | 3.60 | 18.82 | 266.50 | 27.50 |
| February | 23.21 | 07-FEB-15:00 | 28.00 | 21.30 | 6.20 | 18.64 | 178.50 | 219.50 |
| March | 23.05 | 28-MAR-10:00 | 28.00 | 21.00 | 7.20 | 23.82 | 374.50 | 58.00 |
| April | 26.40 | 30-APR-14:00 | 31.00 | 25.00 | 8.70 | 22.98 | 350.50 | 184.00 |
| May | 29.11 | 29-MAY-12:00 | 33.40 | 27.90 | 7.70 | 22.13 | 421.00 | 303.50 |
| June | 29.09 | 04-JUN-18:00 | 33.20 | 28.00 | 4.10 | 21.96 | 16.50 | 15.50 |
| July | 30.86 | 18-JUL-20:00 | 34.00 | 30.00 | 3.60 | 26.32 | 0.00 | 0.00 |
| August | 31.14 | 22-AUG-16:00 | 36.00 | 30.00 | 9.30 | 25.16 | 159.00 | 168.50 |
| September | 30.39 | 09-SEP-13:00 | 36.00 | 29.00 | 5.70 | 28.11 | 339.50 | 377.00 |
| October | 30.18 | 07-OCT-09:00 | 30.60 | 30.10 | 4.60 | 19.87 | 295.50 | 353.00 |
| November | 26.24 | 01-NOV-13:00 | 33.00 | 24.00 | 6.20 | 20.92 | 269.00 | 349.50 |
| December | 23.18 | 05-DEC-14:00 | 26.00 | 22.00 | 4.60 | 16.85 | 185.00 | 295.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 20.89 | 23.00 | 20.00 | 3.60 | 16.85 | 0.00 | 0.00 | |
| Maximum of Months | 31.14 | 36.00 | 30.10 | 9.30 | 28.11 | 421.00 | 377.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 20.00 | 30-JAN-13:00 | 23.00 | 20.89 | 3.60 | 18.82 | 266.50 | 27.50 |
| February | 21.30 | 07-FEB-15:00 | 28.00 | 23.21 | 6.20 | 18.64 | 178.50 | 219.50 |
| March | 22.00 | 31-MAR-09:00 | 23.00 | 22.27 | 0.50 | 10.88 | 323.50 | 305.50 |
| April | 25.00 | 30-APR-14:00 | 31.00 | 26.40 | 8.70 | 22.98 | 350.50 | 184.00 |
| May | 27.90 | 29-MAY-12:00 | 33.40 | 29.11 | 7.70 | 22.13 | 421.00 | 303.50 |
| June | 28.00 | 04-JUN-18:00 | 33.20 | 29.09 | 4.10 | 21.96 | 16.50 | 15.50 |
| July | 30.00 | 19-JUL-23:19 | 34.00 | 30.86 | 0.83 | 25.33 | 0.00 | 0.00 |
| August | 30.00 | 07-AUG-23:19 | 33.00 | 30.56 | 3.43 | 22.30 | 0.00 | 0.00 |
| September | 29.00 | 08-SEP-07:00 | 31.00 | 29.41 | 1.50 | 24.33 | 179.00 | 151.00 |
| October | 30.10 | 07-OCT-09:00 | 30.60 | 30.18 | 4.60 | 19.87 | 295.50 | 353.00 |
| November | 24.00 | 01-NOV-10:00 | 32.00 | 26.10 | 3.10 | 20.05 | 300.50 | 377.00 |
| December | 23.00 | 25-DEC-10:00 | 23.00 | 23.00 | 0.80 | 14.10 | 245.00 | 376.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 20.00 | 23.00 | 20.89 | 0.50 | 10.88 | 0.00 | 0.00 | |
| Maximum of Months | 30.10 | 34.00 | 30.86 | 8.70 | 25.33 | 421.00 | 377.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 24.90 | 26.90 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 25.87 | 32.18 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 28.18 | 38.22 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 31.32 | 44.91 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 34.39 | 50.41 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 36.58 | 52.39 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 37.28 | 50.68 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 36.29 | 48.56 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 33.90 | 43.99 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 30.75 | 37.43 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 27.69 | 30.34 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 25.55 | 25.09 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 31.09 | 40.13 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 24.90 | 25.09 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 37.28 | 52.39 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915241E+09 | -742733163.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172507438.0 | 59.44 | 0.00 | 0.00 |
| February | 0.807766E+09 | -651957079.7 | 0.00 | 0.00 | 672.00 | 0.00 | -155809280.6 | 59.44 | 0.00 | 0.00 |
| March | 0.844672E+09 | -672165018.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172507066.2 | 59.44 | 0.00 | 0.00 |
| April | 0.752136E+09 | -585210792.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166925425.3 | 59.44 | 0.00 | 0.00 |
| May | 0.711115E+09 | -538633022.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172481805.0 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475721644.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166912298.9 | 59.44 | 0.00 | 0.00 |
| July | 0.648963E+09 | -476482906.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172480579.6 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799559.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172477610.7 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408779.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166923426.9 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851170.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172486278.7 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660650143.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166922271.3 | 59.44 | 0.00 | 0.00 |
| December | 0.901229E+09 | -728739258.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172489952.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920928E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203092E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742733163.5 | 0.00 | 0.00 | 672.00 | 0.00 | -172507438.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915241E+09 | -475721644.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155809280.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915336E+09 | -742732698.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172603130.5 | 59.44 | 0.00 | 0.00 |
| February | 0.807816E+09 | -651955077.7 | 0.00 | 0.00 | 672.00 | 0.00 | -155860779.9 | 59.44 | 0.00 | 0.00 |
| March | 0.844701E+09 | -672171867.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172528834.1 | 59.44 | 0.00 | 0.00 |
| April | 0.752136E+09 | -585213551.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166922919.4 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538634849.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172479096.7 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475717526.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166916790.5 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476485745.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172478406.4 | 59.44 | 0.00 | 0.00 |
| August | 0.670275E+09 | -497796321.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172478192.5 | 59.44 | 0.00 | 0.00 |
| September | 0.698333E+09 | -531409786.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166923155.9 | 59.44 | 0.00 | 0.00 |
| October | 0.789339E+09 | -616856844.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172482251.3 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660646237.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166925360.9 | 59.44 | 0.00 | 0.00 |
| December | 0.901237E+09 | -728745464.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172491406.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920946E+10 | -0.717837E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203109E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742732698.1 | 0.00 | 0.00 | 672.00 | 0.00 | -172603130.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915336E+09 | -475717526.8 | 0.00 | 0.00 | 744.00 | 0.00 | -155860779.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915321E+09 | -742732717.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172588595.7 | 59.44 | 0.00 | 0.00 |
| February | 0.807805E+09 | -651955662.5 | 0.00 | 0.00 | 672.00 | 0.00 | -155849746.8 | 59.44 | 0.00 | 0.00 |
| March | 0.844700E+09 | -672170686.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172529166.8 | 59.44 | 0.00 | 0.00 |
| April | 0.752137E+09 | -585212993.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166924139.4 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538632812.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172481173.1 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475718916.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166915327.9 | 59.44 | 0.00 | 0.00 |
| July | 0.648963E+09 | -476482206.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172480320.9 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497800336.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172476360.9 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408441.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166923850.7 | 59.44 | 0.00 | 0.00 |
| October | 0.789339E+09 | -616856177.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172482652.6 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660646990.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166924937.7 | 59.44 | 0.00 | 0.00 |
| December | 0.901234E+09 | -728744329.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172490170.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920943E+10 | -0.717836E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203107E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742732717.2 | 0.00 | 0.00 | 672.00 | 0.00 | -172588595.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915321E+09 | -475718916.6 | 0.00 | 0.00 | 744.00 | 0.00 | -155849746.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915245E+09 | -742733085.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172511726.8 | 59.44 | 0.00 | 0.00 |
| February | 0.807759E+09 | -651957237.6 | 0.00 | 0.00 | 672.00 | 0.00 | -155801793.9 | 59.44 | 0.00 | 0.00 |
| March | 0.844665E+09 | -672164945.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172500030.0 | 59.44 | 0.00 | 0.00 |
| April | 0.752135E+09 | -585210391.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166924777.0 | 59.44 | 0.00 | 0.00 |
| May | 0.711115E+09 | -538632991.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481602.4 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475721340.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166912579.3 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483277.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172480341.4 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799382.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172477691.7 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408779.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166923446.6 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851149.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486310.3 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660650210.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166922229.4 | 59.44 | 0.00 | 0.00 |
| December | 0.901230E+09 | -728739254.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172490345.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920926E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203091E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742733085.5 | 0.00 | 0.00 | 672.00 | 0.00 | -172511726.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915245E+09 | -475721340.8 | 0.00 | 0.00 | 744.00 | 0.00 | -155801793.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915245E+09 | -742733090.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172511636.4 | 59.44 | 0.00 | 0.00 |
| February | 0.807759E+09 | -651957239.3 | 0.00 | 0.00 | 672.00 | 0.00 | -155801680.2 | 59.44 | 0.00 | 0.00 |
| March | 0.844665E+09 | -672164945.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172500143.2 | 59.44 | 0.00 | 0.00 |
| April | 0.752135E+09 | -585210392.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166924777.5 | 59.44 | 0.00 | 0.00 |
| May | 0.711115E+09 | -538632991.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481602.6 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475721341.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166912580.7 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483277.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172480341.7 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799382.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172477691.7 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408779.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166923446.6 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851149.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172486310.4 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660650209.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166922229.5 | 59.44 | 0.00 | 0.00 |
| December | 0.901230E+09 | -728739254.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172490337.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920926E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203091E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742733090.2 | 0.00 | 0.00 | 672.00 | 0.00 | -172511636.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915245E+09 | -475721341.0 | 0.00 | 0.00 | 744.00 | 0.00 | -155801680.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915226E+09 | -742733309.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172492409.0 | 59.44 | 0.00 | 0.00 |
| February | 0.807747E+09 | -651957449.0 | 0.00 | 0.00 | 672.00 | 0.00 | -155789986.4 | 59.44 | 0.00 | 0.00 |
| March | 0.844655E+09 | -672164946.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172490357.4 | 59.44 | 0.00 | 0.00 |
| April | 0.752135E+09 | -585210285.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166924566.3 | 59.44 | 0.00 | 0.00 |
| May | 0.711115E+09 | -538633025.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172481478.5 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475721259.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166912655.8 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483392.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172480265.0 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799342.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172477705.5 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408778.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166923449.7 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851141.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172486317.6 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660650238.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166922202.8 | 59.44 | 0.00 | 0.00 |
| December | 0.901228E+09 | -728739211.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172489112.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920922E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203087E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742733309.2 | 0.00 | 0.00 | 672.00 | 0.00 | -172492409.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915226E+09 | -475721259.1 | 0.00 | 0.00 | 744.00 | 0.00 | -155789986.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.915226E+09 | -742733309.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172492199.5 | 59.44 | 0.00 | 0.00 |
| February | 0.807746E+09 | -651957458.3 | 0.00 | 0.00 | 672.00 | 0.00 | -155788852.7 | 59.44 | 0.00 | 0.00 |
| March | 0.844652E+09 | -672164915.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172487418.6 | 59.44 | 0.00 | 0.00 |
| April | 0.752135E+09 | -585210301.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166924542.0 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538633030.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481468.8 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475721251.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166912661.3 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483399.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172480262.5 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799340.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172477708.1 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408778.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166923451.3 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851140.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172486320.2 | 59.44 | 0.00 | 0.00 |
| November | 0.827572E+09 | -660650240.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166922200.9 | 59.44 | 0.00 | 0.00 |
| December | 0.901228E+09 | -728739209.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172489072.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.920922E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203087E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742733309.5 | 0.00 | 0.00 | 672.00 | 0.00 | -172492199.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.915226E+09 | -475721251.7 | 0.00 | 0.00 | 744.00 | 0.00 | -155788852.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165811E+10 | -0.148548E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172622805.7 | 59.44 | 0.00 | 0.00 |
| February | 0.145976E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155853563.1 | 59.44 | 0.00 | 0.00 |
| March | 0.151684E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172503436.5 | 59.44 | 0.00 | 0.00 |
| April | 0.133736E+10 | -0.117044E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166918263.2 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482061.0 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951437425.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166915689.5 | 59.44 | 0.00 | 0.00 |
| July | 0.112544E+10 | -952963279.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172479155.9 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995579934.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172480612.3 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166916570.2 | 59.44 | 0.00 | 0.00 |
| October | 0.140620E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484629.9 | 59.44 | 0.00 | 0.00 |
| November | 0.148822E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920750.1 | 59.44 | 0.00 | 0.00 |
| December | 0.163002E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172521019.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163879E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203110E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148548E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172622805.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165811E+10 | -951437425.6 | 0.00 | 0.00 | 744.00 | 0.00 | -155853563.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165836E+10 | -0.148549E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172875896.7 | 59.44 | 0.00 | 0.00 |
| February | 0.145984E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155932440.9 | 59.44 | 0.00 | 0.00 |
| March | 0.151685E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172515688.4 | 59.44 | 0.00 | 0.00 |
| April | 0.133736E+10 | -0.117044E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166921180.3 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172479959.5 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951435109.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166917900.0 | 59.44 | 0.00 | 0.00 |
| July | 0.112545E+10 | -952965863.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172480825.1 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995578794.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172479676.4 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917926.0 | 59.44 | 0.00 | 0.00 |
| October | 0.140620E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480965.8 | 59.44 | 0.00 | 0.00 |
| November | 0.148823E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166923500.6 | 59.44 | 0.00 | 0.00 |
| December | 0.163008E+10 | -0.145749E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172591089.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163883E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203152E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148549E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172875896.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165836E+10 | -951435109.4 | 0.00 | 0.00 | 744.00 | 0.00 | -155932440.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165809E+10 | -0.148548E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172611180.5 | 59.44 | 0.00 | 0.00 |
| February | 0.145976E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155845332.5 | 59.44 | 0.00 | 0.00 |
| March | 0.151684E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172501529.6 | 59.44 | 0.00 | 0.00 |
| April | 0.133736E+10 | -0.117044E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166918306.1 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482424.2 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951437528.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166915614.1 | 59.44 | 0.00 | 0.00 |
| July | 0.112544E+10 | -952963323.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172479115.2 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995579942.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172480614.9 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166916571.7 | 59.44 | 0.00 | 0.00 |
| October | 0.140620E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484633.1 | 59.44 | 0.00 | 0.00 |
| November | 0.148822E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920686.1 | 59.44 | 0.00 | 0.00 |
| December | 0.163001E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172517410.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163878E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203107E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148548E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172611180.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165809E+10 | -951437528.5 | 0.00 | 0.00 | 744.00 | 0.00 | -155845332.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165832E+10 | -0.148549E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172828090.0 | 59.44 | 0.00 | 0.00 |
| February | 0.145983E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155914990.0 | 59.44 | 0.00 | 0.00 |
| March | 0.151685E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172513748.0 | 59.44 | 0.00 | 0.00 |
| April | 0.133736E+10 | -0.117044E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920022.6 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480087.4 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951435376.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166915779.5 | 59.44 | 0.00 | 0.00 |
| July | 0.112545E+10 | -952968767.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172480280.9 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995581200.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172478656.4 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166918497.9 | 59.44 | 0.00 | 0.00 |
| October | 0.140620E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172480681.1 | 59.44 | 0.00 | 0.00 |
| November | 0.148823E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166923141.1 | 59.44 | 0.00 | 0.00 |
| December | 0.163007E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172572782.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163882E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203143E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148549E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172828090.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165832E+10 | -951435376.0 | 0.00 | 0.00 | 744.00 | 0.00 | -155914990.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165804E+10 | -0.148548E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172555530.8 | 59.44 | 0.00 | 0.00 |
| February | 0.145972E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155812078.7 | 59.44 | 0.00 | 0.00 |
| March | 0.151683E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172493409.6 | 59.44 | 0.00 | 0.00 |
| April | 0.133735E+10 | -0.117043E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917561.8 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482863.1 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951440279.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166914218.5 | 59.44 | 0.00 | 0.00 |
| July | 0.112544E+10 | -952965936.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172476308.3 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995581039.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172481557.7 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166916494.5 | 59.44 | 0.00 | 0.00 |
| October | 0.140621E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484663.7 | 59.44 | 0.00 | 0.00 |
| November | 0.148822E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919882.5 | 59.44 | 0.00 | 0.00 |
| December | 0.163000E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172503597.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163877E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203096E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148548E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172555530.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165804E+10 | -951440279.6 | 0.00 | 0.00 | 744.00 | 0.00 | -155812078.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165804E+10 | -0.148548E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172555336.5 | 59.44 | 0.00 | 0.00 |
| February | 0.145972E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155811966.2 | 59.44 | 0.00 | 0.00 |
| March | 0.151683E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172493473.3 | 59.44 | 0.00 | 0.00 |
| April | 0.133735E+10 | -0.117043E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917566.6 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482862.8 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951440279.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166914218.6 | 59.44 | 0.00 | 0.00 |
| July | 0.112544E+10 | -952965936.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172476308.3 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995581040.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481557.8 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166916494.5 | 59.44 | 0.00 | 0.00 |
| October | 0.140621E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484663.7 | 59.44 | 0.00 | 0.00 |
| November | 0.148822E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919890.1 | 59.44 | 0.00 | 0.00 |
| December | 0.163000E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172503530.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163877E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203096E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148548E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172555336.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165804E+10 | -951440279.7 | 0.00 | 0.00 | 744.00 | 0.00 | -155811966.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165798E+10 | -0.148548E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172495522.1 | 59.44 | 0.00 | 0.00 |
| February | 0.145970E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155796600.6 | 59.44 | 0.00 | 0.00 |
| March | 0.151683E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490339.6 | 59.44 | 0.00 | 0.00 |
| April | 0.133735E+10 | -0.117043E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917752.2 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482778.8 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951440302.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166914203.3 | 59.44 | 0.00 | 0.00 |
| July | 0.112544E+10 | -952965959.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172476281.1 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995581080.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481561.0 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166916492.3 | 59.44 | 0.00 | 0.00 |
| October | 0.140621E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484664.6 | 59.44 | 0.00 | 0.00 |
| November | 0.148822E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919686.1 | 59.44 | 0.00 | 0.00 |
| December | 0.162999E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172488113.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163876E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148548E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172495522.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165798E+10 | -951440302.4 | 0.00 | 0.00 | 744.00 | 0.00 | -155796600.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.165798E+10 | -0.148548E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172495543.4 | 59.44 | 0.00 | 0.00 |
| February | 0.145970E+10 | -0.130391E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -155796560.3 | 59.44 | 0.00 | 0.00 |
| March | 0.151683E+10 | -0.134434E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490372.1 | 59.44 | 0.00 | 0.00 |
| April | 0.133735E+10 | -0.117043E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166917752.2 | 59.44 | 0.00 | 0.00 |
| May | 0.124974E+10 | -0.107726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482779.0 | 59.44 | 0.00 | 0.00 |
| June | 0.111835E+10 | -951440302.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166914203.4 | 59.44 | 0.00 | 0.00 |
| July | 0.112544E+10 | -952965959.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172476281.1 | 59.44 | 0.00 | 0.00 |
| August | 0.116806E+10 | -995581080.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172481561.1 | 59.44 | 0.00 | 0.00 |
| September | 0.122975E+10 | -0.106283E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166916492.4 | 59.44 | 0.00 | 0.00 |
| October | 0.140621E+10 | -0.123372E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484664.7 | 59.44 | 0.00 | 0.00 |
| November | 0.148822E+10 | -0.132130E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919686.2 | 59.44 | 0.00 | 0.00 |
| December | 0.162999E+10 | -0.145750E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172488116.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163876E+11 | -0.143568E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203086E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.111835E+10 | -0.148548E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -172495543.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.165798E+10 | -951440302.4 | 0.00 | 0.00 | 744.00 | 0.00 | -155796560.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.917684E+09 | -742742916.1 | 0.00 | 0.00 | 744.00 | 0.00 | -174941215.5 | 59.44 | 0.00 | 0.00 |
| February | 0.809118E+09 | -651955241.2 | 0.00 | 0.00 | 672.00 | 0.00 | -157162361.8 | 59.44 | 0.00 | 0.00 |
| March | 0.845265E+09 | -672161296.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173103970.7 | 59.44 | 0.00 | 0.00 |
| April | 0.752209E+09 | -585210706.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166998381.8 | 59.44 | 0.00 | 0.00 |
| May | 0.711115E+09 | -538633006.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172481614.1 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475721365.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166912527.4 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483232.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172480347.6 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799399.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172477656.6 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408779.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166923424.7 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851151.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172486286.6 | 59.44 | 0.00 | 0.00 |
| November | 0.827661E+09 | -660649358.5 | 0.00 | 0.00 | 720.00 | 0.00 | -167011481.3 | 59.44 | 0.00 | 0.00 |
| December | 0.902423E+09 | -728741429.8 | 0.00 | 0.00 | 744.00 | 0.00 | -173681441.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921502E+10 | -0.717836E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203666E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742742916.1 | 0.00 | 0.00 | 672.00 | 0.00 | -174941215.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.917684E+09 | -475721365.5 | 0.00 | 0.00 | 744.00 | 0.00 | -157162361.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.918464E+09 | -742743931.4 | 0.00 | 0.00 | 744.00 | 0.00 | -175720433.4 | 59.44 | 0.00 | 0.00 |
| February | 0.809427E+09 | -651952472.2 | 0.00 | 0.00 | 672.00 | 0.00 | -157474342.0 | 59.44 | 0.00 | 0.00 |
| March | 0.845342E+09 | -672166767.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173175196.2 | 59.44 | 0.00 | 0.00 |
| April | 0.752212E+09 | -585214805.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166997209.0 | 59.44 | 0.00 | 0.00 |
| May | 0.711113E+09 | -538634704.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172478647.0 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475715239.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166918760.9 | 59.44 | 0.00 | 0.00 |
| July | 0.648965E+09 | -476487129.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172477534.3 | 59.44 | 0.00 | 0.00 |
| August | 0.670274E+09 | -497794660.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172479054.6 | 59.44 | 0.00 | 0.00 |
| September | 0.698334E+09 | -531411512.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166921995.4 | 59.44 | 0.00 | 0.00 |
| October | 0.789340E+09 | -616858583.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172481095.2 | 59.44 | 0.00 | 0.00 |
| November | 0.827693E+09 | -660644743.4 | 0.00 | 0.00 | 720.00 | 0.00 | -167048057.0 | 59.44 | 0.00 | 0.00 |
| December | 0.902797E+09 | -728746287.2 | 0.00 | 0.00 | 744.00 | 0.00 | -174050225.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921659E+10 | -0.717837E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203822E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742743931.4 | 0.00 | 0.00 | 672.00 | 0.00 | -175720433.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.918464E+09 | -475715239.7 | 0.00 | 0.00 | 744.00 | 0.00 | -157474342.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.917570E+09 | -742744137.4 | 0.00 | 0.00 | 744.00 | 0.00 | -174825902.8 | 59.44 | 0.00 | 0.00 |
| February | 0.809059E+09 | -651957391.0 | 0.00 | 0.00 | 672.00 | 0.00 | -157101853.4 | 59.44 | 0.00 | 0.00 |
| March | 0.845246E+09 | -672166808.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173078832.3 | 59.44 | 0.00 | 0.00 |
| April | 0.752208E+09 | -585213656.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166994241.1 | 59.44 | 0.00 | 0.00 |
| May | 0.711113E+09 | -538634417.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172478990.0 | 59.44 | 0.00 | 0.00 |
| June | 0.642636E+09 | -475722339.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166913165.1 | 59.44 | 0.00 | 0.00 |
| July | 0.648966E+09 | -476488157.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172477826.1 | 59.44 | 0.00 | 0.00 |
| August | 0.670273E+09 | -497794613.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172478033.8 | 59.44 | 0.00 | 0.00 |
| September | 0.698334E+09 | -531416248.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166917866.9 | 59.44 | 0.00 | 0.00 |
| October | 0.789340E+09 | -616852057.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172487761.2 | 59.44 | 0.00 | 0.00 |
| November | 0.827654E+09 | -660658210.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166996072.2 | 59.44 | 0.00 | 0.00 |
| December | 0.902374E+09 | -728741824.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173632202.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921477E+10 | -0.717839E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203638E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642636E+09 | -742744137.4 | 0.00 | 0.00 | 672.00 | 0.00 | -174825902.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.917570E+09 | -475722339.2 | 0.00 | 0.00 | 744.00 | 0.00 | -157101853.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.918291E+09 | -742742840.9 | 0.00 | 0.00 | 744.00 | 0.00 | -175548403.9 | 59.44 | 0.00 | 0.00 |
| February | 0.809345E+09 | -651959013.3 | 0.00 | 0.00 | 672.00 | 0.00 | -157386288.4 | 59.44 | 0.00 | 0.00 |
| March | 0.845317E+09 | -672165747.9 | 0.00 | 0.00 | 744.00 | 0.00 | -173151545.0 | 59.44 | 0.00 | 0.00 |
| April | 0.752209E+09 | -585213555.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166995500.5 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538634710.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172478910.9 | 59.44 | 0.00 | 0.00 |
| June | 0.642635E+09 | -475722085.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166913271.1 | 59.44 | 0.00 | 0.00 |
| July | 0.648966E+09 | -476488513.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172477514.4 | 59.44 | 0.00 | 0.00 |
| August | 0.670273E+09 | -497795319.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172477639.0 | 59.44 | 0.00 | 0.00 |
| September | 0.698334E+09 | -531415664.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166918365.6 | 59.44 | 0.00 | 0.00 |
| October | 0.789340E+09 | -616852041.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172487722.4 | 59.44 | 0.00 | 0.00 |
| November | 0.827683E+09 | -660657835.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167025584.1 | 59.44 | 0.00 | 0.00 |
| December | 0.902715E+09 | -728746112.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173969357.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921622E+10 | -0.717839E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203783E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642635E+09 | -742742840.9 | 0.00 | 0.00 | 672.00 | 0.00 | -175548403.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.918291E+09 | -475722085.3 | 0.00 | 0.00 | 744.00 | 0.00 | -157386288.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.917443E+09 | -742743895.0 | 0.00 | 0.00 | 744.00 | 0.00 | -174699116.8 | 59.44 | 0.00 | 0.00 |
| February | 0.808778E+09 | -651949802.3 | 0.00 | 0.00 | 672.00 | 0.00 | -156828124.6 | 59.44 | 0.00 | 0.00 |
| March | 0.845064E+09 | -672162280.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172901403.3 | 59.44 | 0.00 | 0.00 |
| April | 0.752168E+09 | -585210972.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166956668.1 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538633312.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172480811.0 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475720893.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166913029.9 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483972.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172479827.1 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799204.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172477742.3 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408763.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166923457.3 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851108.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172486336.6 | 59.44 | 0.00 | 0.00 |
| November | 0.827627E+09 | -660649874.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166977498.2 | 59.44 | 0.00 | 0.00 |
| December | 0.902170E+09 | -728737385.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173432745.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921391E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203556E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742743895.0 | 0.00 | 0.00 | 672.00 | 0.00 | -174699116.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.917443E+09 | -475720893.0 | 0.00 | 0.00 | 744.00 | 0.00 | -156828124.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.917440E+09 | -742743868.2 | 0.00 | 0.00 | 744.00 | 0.00 | -174695634.7 | 59.44 | 0.00 | 0.00 |
| February | 0.808777E+09 | -651949688.6 | 0.00 | 0.00 | 672.00 | 0.00 | -156827487.2 | 59.44 | 0.00 | 0.00 |
| March | 0.845065E+09 | -672162277.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172902430.5 | 59.44 | 0.00 | 0.00 |
| April | 0.752168E+09 | -585210955.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166956875.2 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538633304.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172480825.0 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475720902.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166913023.4 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476483959.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172479837.0 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799207.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172477742.1 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408763.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166923457.4 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851108.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172486336.4 | 59.44 | 0.00 | 0.00 |
| November | 0.827627E+09 | -660649873.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166977573.1 | 59.44 | 0.00 | 0.00 |
| December | 0.902170E+09 | -728737383.9 | 0.00 | 0.00 | 744.00 | 0.00 | -173432467.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921390E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203555E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742743868.2 | 0.00 | 0.00 | 672.00 | 0.00 | -174695634.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.917440E+09 | -475720902.2 | 0.00 | 0.00 | 744.00 | 0.00 | -156827487.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.916735E+09 | -742742997.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173991784.0 | 59.44 | 0.00 | 0.00 |
| February | 0.808526E+09 | -651951180.4 | 0.00 | 0.00 | 672.00 | 0.00 | -156575119.2 | 59.44 | 0.00 | 0.00 |
| March | 0.845002E+09 | -672162862.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172839555.8 | 59.44 | 0.00 | 0.00 |
| April | 0.752167E+09 | -585211098.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166955851.1 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538633424.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172480605.4 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475720806.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166913094.5 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476484067.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172479755.8 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799184.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172477743.8 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408761.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166923457.7 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851106.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172486339.8 | 59.44 | 0.00 | 0.00 |
| November | 0.827608E+09 | -660650068.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166957732.0 | 59.44 | 0.00 | 0.00 |
| December | 0.901871E+09 | -728739438.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173131239.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921257E+10 | -0.717835E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203421E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742742997.0 | 0.00 | 0.00 | 672.00 | 0.00 | -173991784.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.916735E+09 | -475720806.1 | 0.00 | 0.00 | 744.00 | 0.00 | -156575119.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.916734E+09 | -742743004.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173991154.0 | 59.44 | 0.00 | 0.00 |
| February | 0.808527E+09 | -651951199.1 | 0.00 | 0.00 | 672.00 | 0.00 | -156575355.0 | 59.44 | 0.00 | 0.00 |
| March | 0.845003E+09 | -672162861.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172840505.3 | 59.44 | 0.00 | 0.00 |
| April | 0.752167E+09 | -585211099.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166956050.0 | 59.44 | 0.00 | 0.00 |
| May | 0.711114E+09 | -538633416.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172480616.4 | 59.44 | 0.00 | 0.00 |
| June | 0.642634E+09 | -475720810.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166913092.0 | 59.44 | 0.00 | 0.00 |
| July | 0.648964E+09 | -476484062.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172479759.8 | 59.44 | 0.00 | 0.00 |
| August | 0.670277E+09 | -497799185.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172477744.4 | 59.44 | 0.00 | 0.00 |
| September | 0.698332E+09 | -531408761.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166923458.5 | 59.44 | 0.00 | 0.00 |
| October | 0.789337E+09 | -616851106.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172486340.4 | 59.44 | 0.00 | 0.00 |
| November | 0.827608E+09 | -660650067.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166957770.8 | 59.44 | 0.00 | 0.00 |
| December | 0.901871E+09 | -728739429.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173131919.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.921257E+10 | -0.717836E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203421E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.642634E+09 | -742743004.4 | 0.00 | 0.00 | 672.00 | 0.00 | -173991154.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.916734E+09 | -475720810.3 | 0.00 | 0.00 | 744.00 | 0.00 | -156575355.0 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 325.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 308.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 357.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 375.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 405.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 403.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 405.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 395.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 358.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 351.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 318.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 319.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4323.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 308.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 405.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 45978.60 | 38.97 | 20-JAN-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 45978.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 45978.60 | 38.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 2927401.88 | 159.55 | 20-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26540.97 | 44.23 | 13-FEB-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 2953942.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2927401.88 | 159.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 73931.60 | 52.38 | 20-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 73931.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 73931.60 | 52.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 2495656.25 | 169.86 | 20-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 2495656.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2495656.25 | 169.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.204798E+10 | 0.183570E+10 | 2137.05 | 29-JAN-17:05 | 1780.43 | 0.00 |
| February | 0.00 | 0.00 | 0.216234E+10 | 0.187151E+10 | 2701.29 | 07-FEB-16:10 | 2092.72 | 0.00 |
| March | 0.00 | 0.00 | 0.281635E+10 | 0.250201E+10 | 2769.29 | 01-MAR-15:30 | 2769.29 | 0.00 |
| April | 0.00 | 0.00 | 0.383514E+10 | 0.325585E+10 | 3446.42 | 30-APR-16:15 | 2386.75 | 0.00 |
| May | 0.00 | 0.00 | 0.593421E+10 | 0.493169E+10 | 4304.25 | 21-MAY-13:00 | 3848.64 | 0.00 |
| June | 0.00 | 0.00 | 0.726017E+10 | 0.547112E+10 | 4402.97 | 12-JUN-15:10 | 3072.72 | 0.00 |
| July | 0.00 | 0.00 | 0.889898E+10 | 0.653952E+10 | 5237.42 | 30-JUL-16:10 | 3516.44 | 0.00 |
| August | 0.00 | 0.00 | 0.964659E+10 | 0.707072E+10 | 5595.35 | 22-AUG-17:10 | 3463.98 | 0.00 |
| September | 0.00 | 0.00 | 0.836275E+10 | 0.620411E+10 | 5111.87 | 09-SEP-16:02 | 3410.71 | 0.00 |
| October | 0.00 | 0.00 | 0.707102E+10 | 0.566310E+10 | 4503.49 | 07-OCT-16:10 | 3191.74 | 0.00 |
| November | 0.00 | 0.00 | 0.506508E+10 | 0.426223E+10 | 3997.71 | 01-NOV-15:10 | 2926.98 | 0.00 |
| December | 0.00 | 0.00 | 0.310910E+10 | 0.265852E+10 | 2685.33 | 05-DEC-16:10 | 2006.66 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.662097E+11 | 0.522661E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.204798E+10 | 0.183570E+10 | 2137.05 | 1780.43 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.964659E+10 | 0.707072E+10 | 5595.35 | 3848.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.131538E+10 | 0.115439E+10 | 1647.66 | 29-JAN-17:10 | 1341.83 | 0.00 |
| February | 0.00 | 0.00 | 0.157935E+10 | 0.133935E+10 | 2242.88 | 07-FEB-16:20 | 1667.62 | 0.00 |
| March | 0.00 | 0.00 | 0.239039E+10 | 0.210224E+10 | 2478.03 | 27-MAR-16:01 | 2478.03 | 0.00 |
| April | 0.00 | 0.00 | 0.361029E+10 | 0.304809E+10 | 3262.40 | 30-APR-16:15 | 2245.80 | 0.00 |
| May | 0.00 | 0.00 | 0.594871E+10 | 0.494122E+10 | 4282.32 | 31-MAY-18:00 | 3575.73 | 0.00 |
| June | 0.00 | 0.00 | 0.738565E+10 | 0.558242E+10 | 4466.08 | 12-JUN-15:10 | 3114.78 | 0.00 |
| July | 0.00 | 0.00 | 0.894261E+10 | 0.657813E+10 | 5163.41 | 30-JUL-17:10 | 3312.17 | 0.00 |
| August | 0.00 | 0.00 | 0.953296E+10 | 0.696101E+10 | 5552.63 | 22-AUG-17:10 | 3408.96 | 0.00 |
| September | 0.00 | 0.00 | 0.795712E+10 | 0.583018E+10 | 4835.37 | 09-SEP-16:02 | 3183.60 | 0.00 |
| October | 0.00 | 0.00 | 0.638591E+10 | 0.502237E+10 | 4099.12 | 07-OCT-16:10 | 2844.85 | 0.00 |
| November | 0.00 | 0.00 | 0.426858E+10 | 0.352003E+10 | 3474.80 | 01-NOV-16:01 | 2459.35 | 0.00 |
| December | 0.00 | 0.00 | 0.234719E+10 | 0.195994E+10 | 2150.52 | 05-DEC-17:02 | 1516.52 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.616641E+11 | 0.480394E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.131538E+10 | 0.115439E+10 | 1647.66 | 1341.83 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.953296E+10 | 0.696101E+10 | 5552.63 | 3575.73 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.178295E+10 | 0.163666E+10 | 9730.69 | 30-JAN-08:62 | 7919.58 | 0.00 |
| February | 0.00 | 0.00 | 0.189113E+10 | 0.169683E+10 | 9892.54 | 09-FEB-08:62 | 7407.73 | 0.00 |
| March | 0.00 | 0.00 | 0.245077E+10 | 0.224448E+10 | 9983.61 | 29-MAR-07:02 | 6931.52 | 0.00 |
| April | 0.00 | 0.00 | 0.279834E+10 | 0.251030E+10 | 10029.45 | 12-APR-07:02 | 6853.41 | 0.00 |
| May | 0.00 | 0.00 | 0.463649E+10 | 0.406018E+10 | 10367.95 | 24-MAY-06:03 | 5469.59 | 0.00 |
| June | 0.00 | 0.00 | 0.575045E+10 | 0.453406E+10 | 10383.45 | 08-JUN-07:02 | 5026.02 | 0.00 |
| July | 0.00 | 0.00 | 0.713330E+10 | 0.529700E+10 | 10308.55 | 06-JUL-06:03 | 4957.38 | 0.00 |
| August | 0.00 | 0.00 | 0.817887E+10 | 0.604980E+10 | 10307.64 | 31-AUG-06:03 | 6031.83 | 0.00 |
| September | 0.00 | 0.00 | 0.651794E+10 | 0.495359E+10 | 10375.13 | 25-SEP-06:03 | 6485.78 | 0.00 |
| October | 0.00 | 0.00 | 0.546904E+10 | 0.448539E+10 | 10381.48 | 17-OCT-06:03 | 5842.71 | 0.00 |
| November | 0.00 | 0.00 | 0.374823E+10 | 0.322727E+10 | 10175.28 | 03-NOV-07:02 | 6425.66 | 0.00 |
| December | 0.00 | 0.00 | 0.232597E+10 | 0.206495E+10 | 9912.41 | 06-DEC-08:62 | 7216.65 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.526835E+11 | 0.427605E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.178295E+10 | 0.163666E+10 | 9730.69 | 4957.38 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.817887E+10 | 0.604980E+10 | 10383.45 | 7919.58 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.132826E+10 | 0.116733E+10 | 1572.03 | 29-JAN-12:00 | 1333.33 | 0.00 |
| February | 0.00 | 0.00 | 0.157558E+10 | 0.133744E+10 | 2066.73 | 07-FEB-16:20 | 1522.07 | 0.00 |
| March | 0.00 | 0.00 | 0.236105E+10 | 0.207675E+10 | 2416.24 | 27-MAR-11:00 | 2416.24 | 0.00 |
| April | 0.00 | 0.00 | 0.363786E+10 | 0.307676E+10 | 3143.25 | 28-APR-15:10 | 2624.04 | 0.00 |
| May | 0.00 | 0.00 | 0.598919E+10 | 0.498378E+10 | 4341.40 | 21-MAY-13:00 | 3906.57 | 0.00 |
| June | 0.00 | 0.00 | 0.739056E+10 | 0.559008E+10 | 4372.21 | 09-JUN-11:00 | 3205.03 | 0.00 |
| July | 0.00 | 0.00 | 0.895241E+10 | 0.659101E+10 | 5065.51 | 30-JUL-17:10 | 3225.79 | 0.00 |
| August | 0.00 | 0.00 | 0.954699E+10 | 0.697747E+10 | 5360.25 | 22-AUG-17:10 | 3242.54 | 0.00 |
| September | 0.00 | 0.00 | 0.796410E+10 | 0.584059E+10 | 4610.74 | 09-SEP-16:02 | 2994.89 | 0.00 |
| October | 0.00 | 0.00 | 0.640672E+10 | 0.504215E+10 | 3965.25 | 07-OCT-10:40 | 2353.83 | 0.00 |
| November | 0.00 | 0.00 | 0.427344E+10 | 0.352516E+10 | 3310.14 | 01-NOV-15:10 | 2308.00 | 0.00 |
| December | 0.00 | 0.00 | 0.233481E+10 | 0.195025E+10 | 1992.68 | 05-DEC-17:02 | 1384.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.617610E+11 | 0.481588E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.132826E+10 | 0.116733E+10 | 1572.03 | 1333.33 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.954699E+10 | 0.697747E+10 | 5360.25 | 3906.57 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.129760E+10 | 0.114150E+10 | 1328.66 | 29-JAN-17:10 | 1068.37 | 0.00 |
| February | 0.00 | 0.00 | 0.151391E+10 | 0.128314E+10 | 1780.08 | 07-FEB-17:02 | 1345.20 | 0.00 |
| March | 0.00 | 0.00 | 0.218213E+10 | 0.191526E+10 | 1883.91 | 27-MAR-16:04 | 1883.91 | 0.00 |
| April | 0.00 | 0.00 | 0.318011E+10 | 0.267487E+10 | 2563.27 | 30-APR-16:15 | 1760.76 | 0.00 |
| May | 0.00 | 0.00 | 0.504237E+10 | 0.415457E+10 | 3327.22 | 31-MAY-18:00 | 2715.61 | 0.00 |
| June | 0.00 | 0.00 | 0.618672E+10 | 0.462158E+10 | 3406.34 | 12-JUN-15:10 | 2366.07 | 0.00 |
| July | 0.00 | 0.00 | 0.745332E+10 | 0.539766E+10 | 4060.17 | 30-JUL-17:10 | 2579.19 | 0.00 |
| August | 0.00 | 0.00 | 0.786578E+10 | 0.564128E+10 | 4281.36 | 22-AUG-17:10 | 2588.59 | 0.00 |
| September | 0.00 | 0.00 | 0.660422E+10 | 0.475609E+10 | 3735.91 | 09-SEP-16:02 | 2395.09 | 0.00 |
| October | 0.00 | 0.00 | 0.535215E+10 | 0.415106E+10 | 3222.26 | 07-OCT-16:10 | 2180.65 | 0.00 |
| November | 0.00 | 0.00 | 0.364728E+10 | 0.298544E+10 | 2729.48 | 01-NOV-16:01 | 1895.09 | 0.00 |
| December | 0.00 | 0.00 | 0.214453E+10 | 0.178740E+10 | 1747.20 | 05-DEC-17:02 | 1210.79 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.524701E+11 | 0.405099E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.129760E+10 | 0.114150E+10 | 1328.66 | 1068.37 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.786578E+10 | 0.564128E+10 | 4281.36 | 2715.61 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.129875E+10 | 0.114253E+10 | 1327.33 | 29-JAN-17:10 | 1067.31 | 0.00 |
| February | 0.00 | 0.00 | 0.151434E+10 | 0.128352E+10 | 1777.00 | 07-FEB-17:02 | 1342.56 | 0.00 |
| March | 0.00 | 0.00 | 0.218108E+10 | 0.191429E+10 | 1882.07 | 27-MAR-16:04 | 1882.07 | 0.00 |
| April | 0.00 | 0.00 | 0.318155E+10 | 0.267621E+10 | 2562.31 | 30-APR-16:15 | 1760.13 | 0.00 |
| May | 0.00 | 0.00 | 0.504441E+10 | 0.415649E+10 | 3323.56 | 31-MAY-18:00 | 2712.10 | 0.00 |
| June | 0.00 | 0.00 | 0.618719E+10 | 0.462200E+10 | 3405.67 | 12-JUN-15:10 | 2365.74 | 0.00 |
| July | 0.00 | 0.00 | 0.745397E+10 | 0.539823E+10 | 4059.12 | 30-JUL-17:10 | 2578.29 | 0.00 |
| August | 0.00 | 0.00 | 0.786662E+10 | 0.564202E+10 | 4278.07 | 22-AUG-17:10 | 2585.87 | 0.00 |
| September | 0.00 | 0.00 | 0.660481E+10 | 0.475662E+10 | 3732.55 | 09-SEP-16:02 | 2392.49 | 0.00 |
| October | 0.00 | 0.00 | 0.535328E+10 | 0.415203E+10 | 3219.71 | 07-OCT-16:10 | 2178.61 | 0.00 |
| November | 0.00 | 0.00 | 0.364781E+10 | 0.298585E+10 | 2727.06 | 01-NOV-16:01 | 1893.19 | 0.00 |
| December | 0.00 | 0.00 | 0.214438E+10 | 0.178725E+10 | 1744.15 | 05-DEC-17:02 | 1208.36 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.524782E+11 | 0.405170E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.129875E+10 | 0.114253E+10 | 1327.33 | 1067.31 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.786662E+10 | 0.564202E+10 | 4278.07 | 2712.10 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.207188E+10 | 0.186265E+10 | 1822.53 | 29-JAN-17:05 | 1507.33 | 0.00 |
| February | 0.00 | 0.00 | 0.212861E+10 | 0.184462E+10 | 2206.44 | 07-FEB-16:10 | 1725.63 | 0.00 |
| March | 0.00 | 0.00 | 0.263500E+10 | 0.233867E+10 | 2172.94 | 01-MAR-15:10 | 2172.94 | 0.00 |
| April | 0.00 | 0.00 | 0.342578E+10 | 0.289966E+10 | 2754.82 | 30-APR-16:15 | 1906.77 | 0.00 |
| May | 0.00 | 0.00 | 0.504721E+10 | 0.416045E+10 | 3244.54 | 31-MAY-18:00 | 2636.66 | 0.00 |
| June | 0.00 | 0.00 | 0.607792E+10 | 0.452336E+10 | 3404.82 | 04-JUN-17:10 | 2287.91 | 0.00 |
| July | 0.00 | 0.00 | 0.742867E+10 | 0.537376E+10 | 4141.32 | 30-JUL-17:10 | 2632.51 | 0.00 |
| August | 0.00 | 0.00 | 0.800130E+10 | 0.576701E+10 | 4327.78 | 22-AUG-17:10 | 2647.93 | 0.00 |
| September | 0.00 | 0.00 | 0.703752E+10 | 0.514949E+10 | 4015.85 | 09-SEP-16:02 | 2624.07 | 0.00 |
| October | 0.00 | 0.00 | 0.607127E+10 | 0.481675E+10 | 3630.52 | 07-OCT-16:10 | 2529.44 | 0.00 |
| November | 0.00 | 0.00 | 0.447954E+10 | 0.375570E+10 | 3235.43 | 01-NOV-14:10 | 2386.50 | 0.00 |
| December | 0.00 | 0.00 | 0.294022E+10 | 0.251480E+10 | 2243.97 | 05-DEC-16:10 | 1673.74 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.573449E+11 | 0.450069E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.207188E+10 | 0.184462E+10 | 1822.53 | 1507.33 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.800130E+10 | 0.576701E+10 | 4327.78 | 2647.93 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.228426E+10 | 0.206132E+10 | 1957.75 | 29-JAN-17:05 | 1632.86 | 0.00 |
| February | 0.00 | 0.00 | 0.233342E+10 | 0.203034E+10 | 2305.15 | 05-FEB-14:00 | 2178.22 | 0.00 |
| March | 0.00 | 0.00 | 0.287665E+10 | 0.256238E+10 | 2266.71 | 27-MAR-13:00 | 2266.71 | 0.00 |
| April | 0.00 | 0.00 | 0.373262E+10 | 0.317937E+10 | 2944.68 | 30-APR-16:15 | 2070.62 | 0.00 |
| May | 0.00 | 0.00 | 0.542724E+10 | 0.451147E+10 | 3381.60 | 21-MAY-13:00 | 3057.47 | 0.00 |
| June | 0.00 | 0.00 | 0.645837E+10 | 0.486557E+10 | 3595.41 | 04-JUN-17:10 | 2458.79 | 0.00 |
| July | 0.00 | 0.00 | 0.784494E+10 | 0.575108E+10 | 4349.03 | 30-JUL-17:10 | 2812.27 | 0.00 |
| August | 0.00 | 0.00 | 0.840928E+10 | 0.613773E+10 | 4453.45 | 22-AUG-17:10 | 2755.11 | 0.00 |
| September | 0.00 | 0.00 | 0.743996E+10 | 0.551363E+10 | 4192.43 | 09-SEP-16:02 | 2783.61 | 0.00 |
| October | 0.00 | 0.00 | 0.647997E+10 | 0.519297E+10 | 3806.88 | 07-OCT-16:10 | 2689.11 | 0.00 |
| November | 0.00 | 0.00 | 0.484073E+10 | 0.409047E+10 | 3340.83 | 01-NOV-14:10 | 2484.43 | 0.00 |
| December | 0.00 | 0.00 | 0.321675E+10 | 0.276736E+10 | 2341.58 | 05-DEC-16:10 | 1761.58 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.613442E+11 | 0.486637E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.228426E+10 | 0.203034E+10 | 1957.75 | 1632.86 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.840928E+10 | 0.613773E+10 | 4453.45 | 3057.47 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.372756E+10 | 0.332359E+10 | 4497.29 | 29-JAN-17:05 | 3733.54 | 0.00 |
| February | 0.00 | 0.00 | 0.443045E+10 | 0.382960E+10 | 6043.36 | 07-FEB-16:10 | 4605.10 | 0.00 |
| March | 0.00 | 0.00 | 0.640263E+10 | 0.570112E+10 | 6489.67 | 01-MAR-15:30 | 6489.67 | 0.00 |
| April | 0.00 | 0.00 | 0.875387E+10 | 0.744318E+10 | 7956.78 | 30-APR-16:15 | 5451.27 | 0.00 |
| May | 0.00 | 0.00 | 0.128293E+11 | 0.106339E+11 | 10488.84 | 21-MAY-13:00 | 9290.90 | 0.00 |
| June | 0.00 | 0.00 | 0.153668E+11 | 0.114395E+11 | 9964.65 | 12-JUN-15:10 | 6778.08 | 0.00 |
| July | 0.00 | 0.00 | 0.183171E+11 | 0.131819E+11 | 11643.18 | 30-JUL-16:10 | 7531.75 | 0.00 |
| August | 0.00 | 0.00 | 0.191631E+11 | 0.136102E+11 | 12117.29 | 22-AUG-17:10 | 7114.66 | 0.00 |
| September | 0.00 | 0.00 | 0.162230E+11 | 0.116512E+11 | 10855.26 | 09-SEP-16:02 | 6964.97 | 0.00 |
| October | 0.00 | 0.00 | 0.131090E+11 | 0.102335E+11 | 9248.37 | 07-OCT-16:10 | 6331.90 | 0.00 |
| November | 0.00 | 0.00 | 0.899681E+10 | 0.742623E+10 | 8302.76 | 01-NOV-15:10 | 5880.01 | 0.00 |
| December | 0.00 | 0.00 | 0.537068E+10 | 0.454023E+10 | 5524.64 | 05-DEC-15:30 | 4033.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.132690E+12 | 0.103014E+12 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.372756E+10 | 0.332359E+10 | 4497.29 | 3733.54 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.191631E+11 | 0.136102E+11 | 12117.29 | 9290.90 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.220778E+10 | 0.191902E+10 | 3390.74 | 29-JAN-17:10 | 2742.68 | 0.00 |
| February | 0.00 | 0.00 | 0.319555E+10 | 0.270231E+10 | 4987.93 | 07-FEB-16:20 | 3642.47 | 0.00 |
| March | 0.00 | 0.00 | 0.548754E+10 | 0.484175E+10 | 5734.85 | 27-MAR-16:04 | 5734.85 | 0.00 |
| April | 0.00 | 0.00 | 0.825764E+10 | 0.698616E+10 | 7617.68 | 28-APR-15:10 | 6288.44 | 0.00 |
| May | 0.00 | 0.00 | 0.128271E+11 | 0.106287E+11 | 10321.58 | 21-MAY-13:00 | 9169.28 | 0.00 |
| June | 0.00 | 0.00 | 0.155894E+11 | 0.116403E+11 | 10092.18 | 12-JUN-15:10 | 6865.89 | 0.00 |
| July | 0.00 | 0.00 | 0.183641E+11 | 0.132271E+11 | 11368.73 | 30-JUL-16:10 | 7350.14 | 0.00 |
| August | 0.00 | 0.00 | 0.188815E+11 | 0.133505E+11 | 12010.67 | 22-AUG-17:10 | 6995.64 | 0.00 |
| September | 0.00 | 0.00 | 0.153282E+11 | 0.108459E+11 | 10201.89 | 09-SEP-16:02 | 6428.47 | 0.00 |
| October | 0.00 | 0.00 | 0.116238E+11 | 0.887253E+10 | 8314.68 | 07-OCT-16:10 | 5537.41 | 0.00 |
| November | 0.00 | 0.00 | 0.728609E+10 | 0.586428E+10 | 7018.94 | 01-NOV-15:20 | 4715.73 | 0.00 |
| December | 0.00 | 0.00 | 0.374597E+10 | 0.307373E+10 | 4248.52 | 05-DEC-16:10 | 2892.85 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.122795E+12 | 0.939522E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.220778E+10 | 0.191902E+10 | 3390.74 | 2742.68 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.188815E+11 | 0.133505E+11 | 12010.67 | 9169.28 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.376725E+10 | 0.336050E+10 | 4440.36 | 29-JAN-11:50 | 3777.59 | 0.00 |
| February | 0.00 | 0.00 | 0.442936E+10 | 0.382881E+10 | 5724.03 | 05-FEB-14:00 | 5394.46 | 0.00 |
| March | 0.00 | 0.00 | 0.634882E+10 | 0.565006E+10 | 6233.67 | 27-MAR-13:00 | 6233.67 | 0.00 |
| April | 0.00 | 0.00 | 0.882458E+10 | 0.751160E+10 | 7657.47 | 30-APR-15:40 | 5184.70 | 0.00 |
| May | 0.00 | 0.00 | 0.129253E+11 | 0.107285E+11 | 10739.12 | 21-MAY-13:00 | 9534.59 | 0.00 |
| June | 0.00 | 0.00 | 0.153897E+11 | 0.114605E+11 | 9788.18 | 09-JUN-11:00 | 7043.55 | 0.00 |
| July | 0.00 | 0.00 | 0.183497E+11 | 0.132136E+11 | 11323.64 | 30-JUL-16:10 | 7264.13 | 0.00 |
| August | 0.00 | 0.00 | 0.192051E+11 | 0.136488E+11 | 11614.11 | 22-AUG-17:10 | 6685.47 | 0.00 |
| September | 0.00 | 0.00 | 0.162497E+11 | 0.116781E+11 | 10259.86 | 09-SEP-16:02 | 6464.56 | 0.00 |
| October | 0.00 | 0.00 | 0.131666E+11 | 0.102799E+11 | 8900.59 | 07-OCT-13:10 | 5967.40 | 0.00 |
| November | 0.00 | 0.00 | 0.901899E+10 | 0.744120E+10 | 8001.75 | 01-NOV-14:10 | 5730.56 | 0.00 |
| December | 0.00 | 0.00 | 0.535311E+10 | 0.452301E+10 | 5209.51 | 05-DEC-14:00 | 3876.03 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.133028E+12 | 0.103324E+12 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.376725E+10 | 0.336050E+10 | 4440.36 | 3777.59 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.192051E+11 | 0.136488E+11 | 11614.11 | 9534.59 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.223464E+10 | 0.194375E+10 | 3239.39 | 29-JAN-12:00 | 2730.97 | 0.00 |
| February | 0.00 | 0.00 | 0.319058E+10 | 0.269851E+10 | 4526.72 | 07-FEB-16:20 | 3261.42 | 0.00 |
| March | 0.00 | 0.00 | 0.543274E+10 | 0.479056E+10 | 5586.68 | 27-MAR-11:00 | 5586.68 | 0.00 |
| April | 0.00 | 0.00 | 0.832809E+10 | 0.705435E+10 | 7388.67 | 28-APR-15:10 | 6092.40 | 0.00 |
| May | 0.00 | 0.00 | 0.129229E+11 | 0.107231E+11 | 10569.76 | 21-MAY-13:00 | 9410.28 | 0.00 |
| June | 0.00 | 0.00 | 0.156120E+11 | 0.116612E+11 | 9942.49 | 09-JUN-11:00 | 7170.31 | 0.00 |
| July | 0.00 | 0.00 | 0.183964E+11 | 0.132586E+11 | 11050.70 | 30-JUL-16:10 | 7084.37 | 0.00 |
| August | 0.00 | 0.00 | 0.189235E+11 | 0.133890E+11 | 11508.93 | 22-AUG-17:10 | 6568.23 | 0.00 |
| September | 0.00 | 0.00 | 0.153550E+11 | 0.108729E+11 | 9608.15 | 09-SEP-16:02 | 5935.64 | 0.00 |
| October | 0.00 | 0.00 | 0.116832E+11 | 0.891895E+10 | 7923.48 | 07-OCT-10:30 | 4323.83 | 0.00 |
| November | 0.00 | 0.00 | 0.730923E+10 | 0.587899E+10 | 6633.72 | 01-NOV-15:10 | 4419.68 | 0.00 |
| December | 0.00 | 0.00 | 0.372374E+10 | 0.305341E+10 | 3811.46 | 05-DEC-16:10 | 2550.69 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.123112E+12 | 0.942434E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.223464E+10 | 0.194375E+10 | 3239.39 | 2550.69 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.189235E+11 | 0.133890E+11 | 11508.93 | 9410.28 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.236863E+10 | 0.206801E+10 | 2688.89 | 29-JAN-17:10 | 2147.86 | 0.00 |
| February | 0.00 | 0.00 | 0.310324E+10 | 0.262009E+10 | 3773.92 | 07-FEB-17:02 | 2818.43 | 0.00 |
| March | 0.00 | 0.00 | 0.485841E+10 | 0.427140E+10 | 4150.55 | 27-MAR-16:04 | 4150.55 | 0.00 |
| April | 0.00 | 0.00 | 0.698808E+10 | 0.588089E+10 | 5626.28 | 30-APR-16:15 | 3802.00 | 0.00 |
| May | 0.00 | 0.00 | 0.105042E+11 | 0.862200E+10 | 7289.14 | 21-MAY-13:00 | 6541.55 | 0.00 |
| June | 0.00 | 0.00 | 0.126629E+11 | 0.934186E+10 | 7353.64 | 12-JUN-15:10 | 4977.67 | 0.00 |
| July | 0.00 | 0.00 | 0.149137E+11 | 0.105833E+11 | 8502.95 | 30-JUL-17:10 | 5200.84 | 0.00 |
| August | 0.00 | 0.00 | 0.152842E+11 | 0.106398E+11 | 8896.10 | 22-AUG-17:10 | 5113.01 | 0.00 |
| September | 0.00 | 0.00 | 0.125734E+11 | 0.877406E+10 | 7598.16 | 09-SEP-16:02 | 4660.67 | 0.00 |
| October | 0.00 | 0.00 | 0.977810E+10 | 0.738457E+10 | 6348.35 | 07-OCT-16:10 | 4128.33 | 0.00 |
| November | 0.00 | 0.00 | 0.640725E+10 | 0.513658E+10 | 5371.94 | 01-NOV-16:01 | 3592.69 | 0.00 |
| December | 0.00 | 0.00 | 0.369411E+10 | 0.303456E+10 | 3382.85 | 05-DEC-17:04 | 2274.97 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.103136E+12 | 0.783571E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.236863E+10 | 0.206801E+10 | 2688.89 | 2147.86 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.152842E+11 | 0.106398E+11 | 8896.10 | 6541.55 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.237267E+10 | 0.207172E+10 | 2685.65 | 29-JAN-17:10 | 2145.30 | 0.00 |
| February | 0.00 | 0.00 | 0.310459E+10 | 0.262133E+10 | 3766.33 | 07-FEB-17:02 | 2811.98 | 0.00 |
| March | 0.00 | 0.00 | 0.485694E+10 | 0.427004E+10 | 4146.24 | 27-MAR-16:04 | 4146.24 | 0.00 |
| April | 0.00 | 0.00 | 0.699098E+10 | 0.588361E+10 | 5623.86 | 30-APR-16:15 | 3800.43 | 0.00 |
| May | 0.00 | 0.00 | 0.105080E+11 | 0.862563E+10 | 7298.85 | 21-MAY-13:00 | 6550.64 | 0.00 |
| June | 0.00 | 0.00 | 0.126640E+11 | 0.934285E+10 | 7352.40 | 12-JUN-15:10 | 4977.22 | 0.00 |
| July | 0.00 | 0.00 | 0.149151E+11 | 0.105845E+11 | 8500.50 | 30-JUL-17:10 | 5198.81 | 0.00 |
| August | 0.00 | 0.00 | 0.152859E+11 | 0.106413E+11 | 8888.14 | 22-AUG-17:10 | 5106.64 | 0.00 |
| September | 0.00 | 0.00 | 0.125747E+11 | 0.877529E+10 | 7590.44 | 09-SEP-16:02 | 4654.93 | 0.00 |
| October | 0.00 | 0.00 | 0.978057E+10 | 0.738667E+10 | 6342.30 | 07-OCT-16:10 | 4123.65 | 0.00 |
| November | 0.00 | 0.00 | 0.640860E+10 | 0.513767E+10 | 5366.34 | 01-NOV-16:01 | 3588.47 | 0.00 |
| December | 0.00 | 0.00 | 0.369450E+10 | 0.303491E+10 | 3375.52 | 05-DEC-17:04 | 2269.30 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.103157E+12 | 0.783755E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.237267E+10 | 0.207172E+10 | 2685.65 | 2145.30 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.152859E+11 | 0.106413E+11 | 8888.14 | 6550.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.396978E+10 | 0.355666E+10 | 3771.89 | 29-JAN-17:05 | 3113.69 | 0.00 |
| February | 0.00 | 0.00 | 0.436783E+10 | 0.378195E+10 | 4827.15 | 05-FEB-14:00 | 4553.06 | 0.00 |
| March | 0.00 | 0.00 | 0.578233E+10 | 0.514296E+10 | 4891.22 | 01-MAR-15:10 | 4891.22 | 0.00 |
| April | 0.00 | 0.00 | 0.748282E+10 | 0.634064E+10 | 6061.57 | 30-APR-16:15 | 4140.27 | 0.00 |
| May | 0.00 | 0.00 | 0.105000E+11 | 0.862708E+10 | 7454.21 | 21-MAY-13:00 | 6663.49 | 0.00 |
| June | 0.00 | 0.00 | 0.124310E+11 | 0.913959E+10 | 7242.64 | 09-JUN-12:50 | 5252.59 | 0.00 |
| July | 0.00 | 0.00 | 0.148580E+11 | 0.105367E+11 | 8678.99 | 30-JUL-17:10 | 5323.92 | 0.00 |
| August | 0.00 | 0.00 | 0.155608E+11 | 0.108992E+11 | 8993.75 | 22-AUG-17:10 | 5231.74 | 0.00 |
| September | 0.00 | 0.00 | 0.134700E+11 | 0.958219E+10 | 8234.53 | 09-SEP-16:02 | 5184.25 | 0.00 |
| October | 0.00 | 0.00 | 0.112707E+11 | 0.875389E+10 | 7282.44 | 07-OCT-13:10 | 4822.40 | 0.00 |
| November | 0.00 | 0.00 | 0.812774E+10 | 0.671416E+10 | 6590.30 | 01-NOV-14:10 | 4744.23 | 0.00 |
| December | 0.00 | 0.00 | 0.534963E+10 | 0.454009E+10 | 4561.92 | 05-DEC-14:00 | 3441.64 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.113171E+12 | 0.876151E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.396978E+10 | 0.355666E+10 | 3771.89 | 3113.69 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.155608E+11 | 0.108992E+11 | 8993.75 | 6663.49 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.397234E+10 | 0.355903E+10 | 3767.81 | 29-JAN-17:05 | 3110.21 | 0.00 |
| February | 0.00 | 0.00 | 0.436874E+10 | 0.378279E+10 | 4833.12 | 05-FEB-14:00 | 4558.93 | 0.00 |
| March | 0.00 | 0.00 | 0.578088E+10 | 0.514159E+10 | 4886.87 | 01-MAR-15:10 | 4886.87 | 0.00 |
| April | 0.00 | 0.00 | 0.748566E+10 | 0.634332E+10 | 6059.02 | 30-APR-16:15 | 4138.55 | 0.00 |
| May | 0.00 | 0.00 | 0.105038E+11 | 0.863074E+10 | 7463.93 | 21-MAY-13:00 | 6672.62 | 0.00 |
| June | 0.00 | 0.00 | 0.124321E+11 | 0.914059E+10 | 7250.62 | 09-JUN-12:50 | 5260.08 | 0.00 |
| July | 0.00 | 0.00 | 0.148594E+11 | 0.105380E+11 | 8676.52 | 30-JUL-17:10 | 5321.86 | 0.00 |
| August | 0.00 | 0.00 | 0.155625E+11 | 0.109007E+11 | 8985.78 | 22-AUG-17:10 | 5225.34 | 0.00 |
| September | 0.00 | 0.00 | 0.134713E+11 | 0.958338E+10 | 8226.77 | 09-SEP-16:02 | 5178.32 | 0.00 |
| October | 0.00 | 0.00 | 0.112730E+11 | 0.875588E+10 | 7288.40 | 07-OCT-13:10 | 4828.36 | 0.00 |
| November | 0.00 | 0.00 | 0.812891E+10 | 0.671511E+10 | 6591.87 | 01-NOV-14:10 | 4746.24 | 0.00 |
| December | 0.00 | 0.00 | 0.534967E+10 | 0.454008E+10 | 4564.03 | 05-DEC-14:00 | 3443.85 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.113188E+12 | 0.876312E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.397234E+10 | 0.355903E+10 | 3767.81 | 3110.21 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.155625E+11 | 0.109007E+11 | 8985.78 | 6672.62 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.145348E+10 | 0.129118E+10 | 2718.93 | 29-JAN-16:10 | 2324.27 | 0.00 |
| February | 0.00 | 0.00 | 0.195119E+10 | 0.170036E+10 | 3855.90 | 07-FEB-15:40 | 3038.97 | 0.00 |
| March | 0.00 | 0.00 | 0.315008E+10 | 0.282405E+10 | 4344.62 | 01-MAR-15:30 | 4344.62 | 0.00 |
| April | 0.00 | 0.00 | 0.468435E+10 | 0.401862E+10 | 5178.97 | 28-APR-15:10 | 4334.75 | 0.00 |
| May | 0.00 | 0.00 | 0.736249E+10 | 0.616252E+10 | 6982.39 | 21-MAY-13:00 | 6192.01 | 0.00 |
| June | 0.00 | 0.00 | 0.892300E+10 | 0.672284E+10 | 6481.87 | 12-JUN-15:10 | 4512.80 | 0.00 |
| July | 0.00 | 0.00 | 0.107849E+11 | 0.788715E+10 | 7572.54 | 30-JUL-16:10 | 5007.35 | 0.00 |
| August | 0.00 | 0.00 | 0.112498E+11 | 0.811321E+10 | 7635.64 | 22-AUG-17:10 | 4593.12 | 0.00 |
| September | 0.00 | 0.00 | 0.926641E+10 | 0.673112E+10 | 6837.33 | 09-SEP-16:02 | 4534.35 | 0.00 |
| October | 0.00 | 0.00 | 0.717910E+10 | 0.564570E+10 | 5798.00 | 07-OCT-16:10 | 4083.50 | 0.00 |
| November | 0.00 | 0.00 | 0.454344E+10 | 0.376542E+10 | 5240.71 | 01-NOV-15:10 | 3788.74 | 0.00 |
| December | 0.00 | 0.00 | 0.233652E+10 | 0.197974E+10 | 3398.13 | 05-DEC-15:10 | 2525.58 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.728848E+11 | 0.568419E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.145348E+10 | 0.129118E+10 | 2718.93 | 2324.27 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.112498E+11 | 0.811321E+10 | 7635.64 | 6192.01 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.731376E+09 | 0.626487E+09 | 2050.40 | 29-JAN-16:10 | 1686.76 | 0.00 |
| February | 0.00 | 0.00 | 0.133626E+10 | 0.113440E+10 | 3143.98 | 07-FEB-16:10 | 2324.79 | 0.00 |
| March | 0.00 | 0.00 | 0.266976E+10 | 0.236934E+10 | 3797.13 | 01-MAR-15:30 | 3797.13 | 0.00 |
| April | 0.00 | 0.00 | 0.441662E+10 | 0.376777E+10 | 5006.34 | 28-APR-15:10 | 4160.65 | 0.00 |
| May | 0.00 | 0.00 | 0.736417E+10 | 0.615907E+10 | 6880.52 | 21-MAY-13:00 | 6110.06 | 0.00 |
| June | 0.00 | 0.00 | 0.904583E+10 | 0.683182E+10 | 6551.68 | 12-JUN-15:10 | 4560.35 | 0.00 |
| July | 0.00 | 0.00 | 0.108100E+11 | 0.790859E+10 | 7393.59 | 30-JUL-16:10 | 4877.94 | 0.00 |
| August | 0.00 | 0.00 | 0.110937E+11 | 0.796412E+10 | 7563.52 | 22-AUG-17:10 | 4517.26 | 0.00 |
| September | 0.00 | 0.00 | 0.878447E+10 | 0.628853E+10 | 6419.62 | 09-SEP-16:02 | 4179.58 | 0.00 |
| October | 0.00 | 0.00 | 0.638283E+10 | 0.490699E+10 | 5212.44 | 07-OCT-16:10 | 3573.80 | 0.00 |
| November | 0.00 | 0.00 | 0.363923E+10 | 0.293482E+10 | 4424.53 | 01-NOV-15:10 | 3040.27 | 0.00 |
| December | 0.00 | 0.00 | 0.152206E+10 | 0.124200E+10 | 2518.86 | 05-DEC-16:10 | 1735.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.677964E+11 | 0.521339E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.731376E+09 | 0.626487E+09 | 2050.40 | 1686.76 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.110937E+11 | 0.796412E+10 | 7563.52 | 6110.06 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.145788E+10 | 0.129648E+10 | 2672.54 | 29-JAN-12:00 | 2306.76 | 0.00 |
| February | 0.00 | 0.00 | 0.194147E+10 | 0.169288E+10 | 3656.48 | 05-FEB-14:00 | 3458.41 | 0.00 |
| March | 0.00 | 0.00 | 0.311896E+10 | 0.279601E+10 | 4169.76 | 27-MAR-13:00 | 4169.76 | 0.00 |
| April | 0.00 | 0.00 | 0.472669E+10 | 0.406091E+10 | 5098.09 | 28-APR-14:20 | 4351.81 | 0.00 |
| May | 0.00 | 0.00 | 0.741738E+10 | 0.621837E+10 | 7148.65 | 21-MAY-13:00 | 6358.26 | 0.00 |
| June | 0.00 | 0.00 | 0.893952E+10 | 0.673946E+10 | 6383.50 | 09-JUN-12:30 | 4746.38 | 0.00 |
| July | 0.00 | 0.00 | 0.108031E+11 | 0.790717E+10 | 7307.77 | 30-JUL-16:10 | 4779.77 | 0.00 |
| August | 0.00 | 0.00 | 0.112733E+11 | 0.813686E+10 | 7252.65 | 22-AUG-17:10 | 4264.46 | 0.00 |
| September | 0.00 | 0.00 | 0.928322E+10 | 0.674969E+10 | 6404.22 | 09-SEP-16:02 | 4163.95 | 0.00 |
| October | 0.00 | 0.00 | 0.721383E+10 | 0.567415E+10 | 5682.17 | 07-OCT-13:20 | 3961.49 | 0.00 |
| November | 0.00 | 0.00 | 0.455760E+10 | 0.377528E+10 | 5079.87 | 01-NOV-14:10 | 3719.18 | 0.00 |
| December | 0.00 | 0.00 | 0.231921E+10 | 0.196434E+10 | 3253.56 | 05-DEC-13:50 | 2451.41 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.730522E+11 | 0.570116E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.145788E+10 | 0.129648E+10 | 2672.54 | 2306.76 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.112733E+11 | 0.813686E+10 | 7307.77 | 6358.26 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.724741E+09 | 0.621367E+09 | 1952.50 | 29-JAN-12:00 | 1651.11 | 0.00 |
| February | 0.00 | 0.00 | 0.132141E+10 | 0.112240E+10 | 2805.16 | 07-FEB-16:10 | 2043.13 | 0.00 |
| March | 0.00 | 0.00 | 0.263761E+10 | 0.234046E+10 | 3696.22 | 27-MAR-13:00 | 3696.22 | 0.00 |
| April | 0.00 | 0.00 | 0.445896E+10 | 0.380995E+10 | 4896.83 | 28-APR-14:20 | 4148.32 | 0.00 |
| May | 0.00 | 0.00 | 0.741908E+10 | 0.621506E+10 | 7052.99 | 21-MAY-13:00 | 6281.33 | 0.00 |
| June | 0.00 | 0.00 | 0.906222E+10 | 0.684847E+10 | 6402.86 | 09-JUN-12:30 | 4756.31 | 0.00 |
| July | 0.00 | 0.00 | 0.108281E+11 | 0.792857E+10 | 7129.67 | 30-JUL-16:10 | 4651.80 | 0.00 |
| August | 0.00 | 0.00 | 0.111173E+11 | 0.798783E+10 | 7181.35 | 22-AUG-17:10 | 4189.81 | 0.00 |
| September | 0.00 | 0.00 | 0.880155E+10 | 0.630718E+10 | 5988.15 | 09-SEP-16:02 | 3814.84 | 0.00 |
| October | 0.00 | 0.00 | 0.641883E+10 | 0.493524E+10 | 4907.79 | 07-OCT-13:30 | 3286.26 | 0.00 |
| November | 0.00 | 0.00 | 0.365305E+10 | 0.294308E+10 | 4175.61 | 01-NOV-14:10 | 2896.72 | 0.00 |
| December | 0.00 | 0.00 | 0.149806E+10 | 0.122100E+10 | 2224.05 | 05-DEC-13:50 | 1559.25 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.679409E+11 | 0.522806E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.724741E+09 | 0.621367E+09 | 1952.50 | 1559.25 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.111173E+11 | 0.798783E+10 | 7181.35 | 6281.33 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.686753E+09 | 0.585671E+09 | 1558.80 | 29-JAN-16:10 | 1268.44 | 0.00 |
| February | 0.00 | 0.00 | 0.120011E+10 | 0.101179E+10 | 2300.63 | 07-FEB-16:20 | 1703.14 | 0.00 |
| March | 0.00 | 0.00 | 0.229505E+10 | 0.202788E+10 | 2757.27 | 27-MAR-13:00 | 2757.27 | 0.00 |
| April | 0.00 | 0.00 | 0.372126E+10 | 0.316384E+10 | 3653.23 | 28-APR-15:10 | 3063.06 | 0.00 |
| May | 0.00 | 0.00 | 0.606972E+10 | 0.505362E+10 | 4947.64 | 21-MAY-13:00 | 4448.10 | 0.00 |
| June | 0.00 | 0.00 | 0.738841E+10 | 0.555893E+10 | 4839.80 | 09-JUN-13:00 | 3627.16 | 0.00 |
| July | 0.00 | 0.00 | 0.883270E+10 | 0.643194E+10 | 5460.44 | 30-JUL-16:10 | 3654.76 | 0.00 |
| August | 0.00 | 0.00 | 0.902993E+10 | 0.645158E+10 | 5582.54 | 22-AUG-17:10 | 3343.25 | 0.00 |
| September | 0.00 | 0.00 | 0.721964E+10 | 0.514189E+10 | 4762.49 | 09-SEP-16:02 | 3066.63 | 0.00 |
| October | 0.00 | 0.00 | 0.535845E+10 | 0.409331E+10 | 3950.17 | 07-OCT-16:10 | 2676.52 | 0.00 |
| November | 0.00 | 0.00 | 0.315521E+10 | 0.253373E+10 | 3302.02 | 01-NOV-15:10 | 2263.04 | 0.00 |
| December | 0.00 | 0.00 | 0.140105E+10 | 0.113888E+10 | 1880.28 | 05-DEC-16:10 | 1282.58 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.563583E+11 | 0.431931E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.686753E+09 | 0.585671E+09 | 1558.80 | 1268.44 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.902993E+10 | 0.645158E+10 | 5582.54 | 4448.10 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.690273E+09 | 0.588910E+09 | 1555.81 | 29-JAN-16:10 | 1266.18 | 0.00 |
| February | 0.00 | 0.00 | 0.120194E+10 | 0.101352E+10 | 2292.49 | 07-FEB-16:20 | 1696.49 | 0.00 |
| March | 0.00 | 0.00 | 0.229515E+10 | 0.202800E+10 | 2766.20 | 27-MAR-13:00 | 2766.20 | 0.00 |
| April | 0.00 | 0.00 | 0.372353E+10 | 0.316600E+10 | 3653.43 | 28-APR-15:10 | 3063.38 | 0.00 |
| May | 0.00 | 0.00 | 0.607232E+10 | 0.505609E+10 | 4957.14 | 21-MAY-13:00 | 4457.04 | 0.00 |
| June | 0.00 | 0.00 | 0.738943E+10 | 0.555980E+10 | 4847.29 | 09-JUN-13:00 | 3634.41 | 0.00 |
| July | 0.00 | 0.00 | 0.883375E+10 | 0.643284E+10 | 5455.60 | 30-JUL-16:10 | 3650.70 | 0.00 |
| August | 0.00 | 0.00 | 0.903115E+10 | 0.645260E+10 | 5572.33 | 22-AUG-17:10 | 3334.71 | 0.00 |
| September | 0.00 | 0.00 | 0.722073E+10 | 0.514289E+10 | 4753.15 | 09-SEP-16:02 | 3059.20 | 0.00 |
| October | 0.00 | 0.00 | 0.536039E+10 | 0.409490E+10 | 3942.29 | 07-OCT-16:10 | 2670.04 | 0.00 |
| November | 0.00 | 0.00 | 0.315677E+10 | 0.253499E+10 | 3298.24 | 01-NOV-15:10 | 2260.52 | 0.00 |
| December | 0.00 | 0.00 | 0.140255E+10 | 0.114024E+10 | 1873.37 | 05-DEC-16:10 | 1277.48 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.563780E+11 | 0.432108E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.690273E+09 | 0.588910E+09 | 1555.81 | 1266.18 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.903115E+10 | 0.645260E+10 | 5572.33 | 4457.04 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.145187E+10 | 0.129054E+10 | 2248.90 | 29-JAN-15:10 | 1866.93 | 0.00 |
| February | 0.00 | 0.00 | 0.184068E+10 | 0.160039E+10 | 3096.61 | 05-FEB-14:00 | 2931.12 | 0.00 |
| March | 0.00 | 0.00 | 0.278664E+10 | 0.249172E+10 | 3289.53 | 01-MAR-15:10 | 3289.53 | 0.00 |
| April | 0.00 | 0.00 | 0.399343E+10 | 0.341723E+10 | 3880.45 | 30-APR-15:40 | 2732.30 | 0.00 |
| May | 0.00 | 0.00 | 0.607080E+10 | 0.505707E+10 | 5049.49 | 21-MAY-13:00 | 4525.03 | 0.00 |
| June | 0.00 | 0.00 | 0.726754E+10 | 0.544912E+10 | 4827.41 | 09-JUN-13:00 | 3623.11 | 0.00 |
| July | 0.00 | 0.00 | 0.881035E+10 | 0.641022E+10 | 5640.11 | 30-JUL-16:10 | 3782.94 | 0.00 |
| August | 0.00 | 0.00 | 0.919056E+10 | 0.660171E+10 | 5649.97 | 22-AUG-17:10 | 3418.16 | 0.00 |
| September | 0.00 | 0.00 | 0.770875E+10 | 0.558828E+10 | 5178.28 | 09-SEP-16:02 | 3418.85 | 0.00 |
| October | 0.00 | 0.00 | 0.616516E+10 | 0.483962E+10 | 4675.85 | 07-OCT-13:30 | 3270.29 | 0.00 |
| November | 0.00 | 0.00 | 0.407457E+10 | 0.337807E+10 | 4191.42 | 01-NOV-14:10 | 3107.98 | 0.00 |
| December | 0.00 | 0.00 | 0.224975E+10 | 0.190746E+10 | 2829.22 | 05-DEC-13:50 | 2166.20 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.616101E+11 | 0.480314E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.145187E+10 | 0.129054E+10 | 2248.90 | 1866.93 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.919056E+10 | 0.660171E+10 | 5649.97 | 4525.03 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.145395E+10 | 0.129354E+10 | 2248.53 | 29-JAN-15:10 | 1868.03 | 0.00 |
| February | 0.00 | 0.00 | 0.184070E+10 | 0.160177E+10 | 3100.22 | 05-FEB-14:00 | 2936.47 | 0.00 |
| March | 0.00 | 0.00 | 0.278483E+10 | 0.249165E+10 | 3284.81 | 01-MAR-15:10 | 3284.81 | 0.00 |
| April | 0.00 | 0.00 | 0.399340E+10 | 0.341921E+10 | 3876.84 | 30-APR-15:40 | 2730.58 | 0.00 |
| May | 0.00 | 0.00 | 0.607042E+10 | 0.505932E+10 | 5055.62 | 21-MAY-13:00 | 4533.73 | 0.00 |
| June | 0.00 | 0.00 | 0.726539E+10 | 0.544976E+10 | 4832.92 | 09-JUN-13:00 | 3630.26 | 0.00 |
| July | 0.00 | 0.00 | 0.880798E+10 | 0.641084E+10 | 5633.99 | 30-JUL-16:10 | 3778.72 | 0.00 |
| August | 0.00 | 0.00 | 0.918826E+10 | 0.660245E+10 | 5638.41 | 22-AUG-17:10 | 3409.50 | 0.00 |
| September | 0.00 | 0.00 | 0.770662E+10 | 0.558899E+10 | 5167.41 | 09-SEP-16:02 | 3411.14 | 0.00 |
| October | 0.00 | 0.00 | 0.616404E+10 | 0.484090E+10 | 4678.51 | 07-OCT-13:30 | 3274.78 | 0.00 |
| November | 0.00 | 0.00 | 0.407333E+10 | 0.337897E+10 | 4190.78 | 01-NOV-14:10 | 3109.35 | 0.00 |
| December | 0.00 | 0.00 | 0.224918E+10 | 0.190842E+10 | 2830.62 | 05-DEC-13:50 | 2169.07 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.615981E+11 | 0.480458E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.145395E+10 | 0.129354E+10 | 2248.53 | 1868.03 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.918826E+10 | 0.660245E+10 | 5638.41 | 4533.73 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.139888E+09 | 1.01 | 141.09 | 29-JAN-17:05 | 1.02 |
| February | 0.146588E+09 | 1.00 | 178.23 | 05-FEB-15:10 | 1.01 |
| March | 0.193296E+09 | 1.01 | 204.52 | 01-MAR-15:30 | 1.01 |
| April | 0.261750E+09 | 1.03 | 226.30 | 28-APR-15:10 | 1.00 |
| May | 0.406325E+09 | 1.02 | 298.68 | 21-MAY-13:00 | 0.97 |
| June | 0.484997E+09 | 1.01 | 298.71 | 09-JUN-16:30 | 0.97 |
| July | 0.592554E+09 | 0.99 | 334.49 | 30-JUL-16:10 | 0.95 |
| August | 0.638880E+09 | 0.99 | 361.74 | 10-AUG-16:10 | 0.95 |
| September | 0.549590E+09 | 1.00 | 321.94 | 09-SEP-16:02 | 0.96 |
| October | 0.469784E+09 | 1.01 | 288.29 | 07-OCT-16:10 | 0.97 |
| November | 0.338175E+09 | 1.03 | 256.13 | 01-NOV-15:10 | 0.98 |
| December | 0.208990E+09 | 1.04 | 172.66 | 05-DEC-16:10 | 1.01 |
| Annual Sum or Average | 0.443082E+10 | 1.01 | |||
| Minimum of Months | 0.139888E+09 | 0.99 | 141.09 | 0.95 | |
| Maximum of Months | 0.638880E+09 | 1.04 | 361.74 | 1.02 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 89929783.99 | 0.90 | 109.19 | 29-JAN-17:10 | 1.03 |
| February | 0.107107E+09 | 0.95 | 145.99 | 07-FEB-16:20 | 1.02 |
| March | 0.164111E+09 | 0.99 | 180.34 | 27-MAR-16:01 | 1.01 |
| April | 0.246156E+09 | 1.03 | 218.88 | 28-APR-15:10 | 1.00 |
| May | 0.406228E+09 | 1.02 | 296.72 | 31-MAY-18:00 | 0.97 |
| June | 0.491826E+09 | 1.00 | 304.66 | 09-JUN-16:40 | 0.97 |
| July | 0.593634E+09 | 0.99 | 326.96 | 30-JUL-16:10 | 0.95 |
| August | 0.629549E+09 | 0.99 | 357.41 | 10-AUG-16:10 | 0.94 |
| September | 0.521929E+09 | 1.00 | 304.36 | 09-SEP-16:02 | 0.96 |
| October | 0.424019E+09 | 1.02 | 262.64 | 07-OCT-16:10 | 0.98 |
| November | 0.285264E+09 | 1.03 | 222.89 | 01-NOV-16:01 | 0.99 |
| December | 0.157868E+09 | 1.02 | 137.90 | 05-DEC-17:02 | 1.02 |
| Annual Sum or Average | 0.411762E+10 | 1.00 | |||
| Minimum of Months | 89929783.99 | 0.90 | 109.19 | 0.94 | |
| Maximum of Months | 0.629549E+09 | 1.03 | 357.41 | 1.03 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.148196E+10 | 0.91 | 553.30 | 01-JAN-00:10 | 0.91 |
| February | 0.133855E+10 | 0.91 | 553.30 | 01-FEB-00:10 | 0.91 |
| March | 0.148196E+10 | 0.91 | 553.30 | 01-MAR-00:10 | 0.91 |
| April | 0.143416E+10 | 0.91 | 553.30 | 01-APR-00:10 | 0.90 |
| May | 0.148196E+10 | 0.91 | 553.30 | 01-MAY-00:10 | 0.90 |
| June | 0.143416E+10 | 0.90 | 553.30 | 01-JUN-00:10 | 0.91 |
| July | 0.148196E+10 | 0.90 | 553.30 | 01-JUL-00:10 | 0.90 |
| August | 0.148196E+10 | 0.90 | 553.30 | 01-AUG-00:10 | 0.90 |
| September | 0.143416E+10 | 0.90 | 553.30 | 01-SEP-00:10 | 0.90 |
| October | 0.148196E+10 | 0.91 | 553.30 | 01-OCT-00:10 | 0.90 |
| November | 0.143416E+10 | 0.91 | 553.30 | 01-NOV-00:10 | 0.91 |
| December | 0.148196E+10 | 0.91 | 553.30 | 01-DEC-00:10 | 0.91 |
| Annual Sum or Average | 0.174489E+11 | 0.91 | |||
| Minimum of Months | 0.133855E+10 | 0.90 | 553.30 | 0.90 | |
| Maximum of Months | 0.148196E+10 | 0.91 | 553.30 | 0.91 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 90450370.90 | 0.91 | 105.42 | 29-JAN-12:00 | 1.03 |
| February | 0.106423E+09 | 0.96 | 134.09 | 07-FEB-16:20 | 1.02 |
| March | 0.161461E+09 | 0.98 | 183.82 | 27-MAR-11:00 | 1.01 |
| April | 0.246969E+09 | 1.03 | 212.93 | 28-APR-12:20 | 1.00 |
| May | 0.406973E+09 | 1.02 | 298.38 | 21-MAY-13:00 | 0.97 |
| June | 0.489520E+09 | 1.00 | 290.79 | 09-JUN-13:00 | 0.96 |
| July | 0.590910E+09 | 0.99 | 317.52 | 30-JUL-16:10 | 0.95 |
| August | 0.626791E+09 | 0.98 | 341.70 | 10-AUG-16:10 | 0.95 |
| September | 0.519569E+09 | 1.00 | 288.89 | 09-SEP-16:02 | 0.96 |
| October | 0.423121E+09 | 1.01 | 250.24 | 07-OCT-16:10 | 0.98 |
| November | 0.284195E+09 | 1.03 | 211.41 | 01-NOV-14:10 | 0.99 |
| December | 0.156382E+09 | 1.03 | 127.22 | 05-DEC-17:02 | 1.02 |
| Annual Sum or Average | 0.410276E+10 | 1.00 | |||
| Minimum of Months | 90450370.90 | 0.91 | 105.42 | 0.95 | |
| Maximum of Months | 0.626791E+09 | 1.03 | 341.70 | 1.03 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 87533752.89 | 1.00 | 86.82 | 29-JAN-17:10 | 1.03 |
| February | 0.101227E+09 | 1.02 | 114.91 | 07-FEB-17:02 | 1.02 |
| March | 0.147632E+09 | 1.02 | 138.71 | 27-MAR-11:00 | 1.02 |
| April | 0.213623E+09 | 1.04 | 165.04 | 28-APR-12:00 | 1.01 |
| May | 0.339233E+09 | 1.02 | 228.04 | 31-MAY-18:00 | 0.98 |
| June | 0.405963E+09 | 1.00 | 229.27 | 09-JUN-16:50 | 0.98 |
| July | 0.487382E+09 | 0.99 | 252.72 | 30-JUL-17:10 | 0.96 |
| August | 0.511948E+09 | 0.99 | 271.78 | 10-AUG-16:10 | 0.96 |
| September | 0.426784E+09 | 1.00 | 232.96 | 09-SEP-16:02 | 0.97 |
| October | 0.349941E+09 | 1.02 | 204.03 | 07-OCT-16:10 | 0.98 |
| November | 0.240181E+09 | 1.03 | 173.07 | 01-NOV-16:01 | 1.00 |
| December | 0.142198E+09 | 1.04 | 110.45 | 05-DEC-17:02 | 1.02 |
| Annual Sum or Average | 0.345365E+10 | 1.01 | |||
| Minimum of Months | 87533752.89 | 0.99 | 86.82 | 0.96 | |
| Maximum of Months | 0.511948E+09 | 1.04 | 271.78 | 1.03 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 87600738.47 | 1.00 | 86.73 | 29-JAN-17:10 | 1.03 |
| February | 0.101244E+09 | 1.02 | 114.70 | 07-FEB-17:02 | 1.02 |
| March | 0.147545E+09 | 1.02 | 139.03 | 27-MAR-11:00 | 1.02 |
| April | 0.213695E+09 | 1.04 | 165.42 | 28-APR-12:00 | 1.01 |
| May | 0.339326E+09 | 1.02 | 227.76 | 31-MAY-18:00 | 0.98 |
| June | 0.405938E+09 | 1.00 | 228.97 | 09-JUN-16:50 | 0.98 |
| July | 0.487353E+09 | 0.99 | 252.61 | 30-JUL-17:10 | 0.96 |
| August | 0.511926E+09 | 0.99 | 271.56 | 10-AUG-16:10 | 0.96 |
| September | 0.426763E+09 | 1.00 | 232.72 | 09-SEP-16:02 | 0.97 |
| October | 0.349966E+09 | 1.02 | 203.85 | 07-OCT-16:10 | 0.98 |
| November | 0.240184E+09 | 1.03 | 172.90 | 01-NOV-16:01 | 1.00 |
| December | 0.142171E+09 | 1.04 | 110.25 | 05-DEC-17:02 | 1.02 |
| Annual Sum or Average | 0.345371E+10 | 1.01 | |||
| Minimum of Months | 87600738.47 | 0.99 | 86.73 | 0.96 | |
| Maximum of Months | 0.511926E+09 | 1.04 | 271.56 | 1.03 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.139560E+09 | 1.05 | 118.62 | 29-JAN-17:05 | 1.02 |
| February | 0.142260E+09 | 1.04 | 148.38 | 05-FEB-14:00 | 1.01 |
| March | 0.178234E+09 | 1.03 | 159.39 | 27-MAR-12:00 | 1.01 |
| April | 0.230433E+09 | 1.04 | 176.78 | 28-APR-12:00 | 1.01 |
| May | 0.340671E+09 | 1.02 | 223.57 | 31-MAY-18:00 | 0.98 |
| June | 0.400337E+09 | 1.01 | 226.42 | 09-JUN-14:20 | 0.98 |
| July | 0.487608E+09 | 1.00 | 258.50 | 30-JUL-17:10 | 0.96 |
| August | 0.522657E+09 | 0.99 | 276.36 | 10-AUG-16:10 | 0.96 |
| September | 0.455992E+09 | 1.00 | 250.74 | 09-SEP-16:02 | 0.97 |
| October | 0.397403E+09 | 1.01 | 229.85 | 07-OCT-16:10 | 0.98 |
| November | 0.294726E+09 | 1.03 | 206.74 | 01-NOV-14:10 | 0.99 |
| December | 0.194781E+09 | 1.04 | 143.55 | 04-DEC-13:00 | 1.01 |
| Annual Sum or Average | 0.378466E+10 | 1.02 | |||
| Minimum of Months | 0.139560E+09 | 0.99 | 118.62 | 0.96 | |
| Maximum of Months | 0.522657E+09 | 1.05 | 276.36 | 1.02 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.153866E+09 | 1.05 | 127.35 | 29-JAN-17:05 | 1.02 |
| February | 0.155930E+09 | 1.04 | 157.50 | 05-FEB-14:00 | 1.01 |
| March | 0.194469E+09 | 1.04 | 167.53 | 27-MAR-12:00 | 1.01 |
| April | 0.250849E+09 | 1.03 | 186.79 | 30-APR-16:15 | 0.99 |
| May | 0.365981E+09 | 1.02 | 234.23 | 21-MAY-13:00 | 0.98 |
| June | 0.425300E+09 | 1.00 | 233.19 | 09-JUN-14:20 | 0.98 |
| July | 0.514917E+09 | 0.99 | 271.36 | 30-JUL-17:10 | 0.96 |
| August | 0.549281E+09 | 0.99 | 282.98 | 10-AUG-16:10 | 0.96 |
| September | 0.481984E+09 | 1.00 | 261.80 | 09-SEP-16:02 | 0.96 |
| October | 0.423871E+09 | 1.01 | 240.96 | 07-OCT-16:10 | 0.97 |
| November | 0.318273E+09 | 1.02 | 213.54 | 01-NOV-14:10 | 0.98 |
| December | 0.213059E+09 | 1.04 | 151.30 | 03-DEC-14:50 | 1.01 |
| Annual Sum or Average | 0.404778E+10 | 1.02 | |||
| Minimum of Months | 0.153866E+09 | 0.99 | 127.35 | 0.96 | |
| Maximum of Months | 0.549281E+09 | 1.05 | 282.98 | 1.02 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.254353E+09 | 0.89 | 297.94 | 29-JAN-16:10 | 1.02 |
| February | 0.299983E+09 | 0.96 | 403.94 | 05-FEB-15:10 | 1.01 |
| March | 0.438544E+09 | 1.01 | 476.60 | 01-MAR-15:30 | 1.00 |
| April | 0.595766E+09 | 1.03 | 529.69 | 28-APR-15:10 | 0.99 |
| May | 0.876940E+09 | 1.02 | 716.75 | 21-MAY-13:00 | 0.96 |
| June | 0.102399E+10 | 1.01 | 669.97 | 09-JUN-16:10 | 0.97 |
| July | 0.121695E+10 | 1.00 | 735.26 | 30-JUL-16:10 | 0.95 |
| August | 0.126700E+10 | 0.99 | 771.61 | 10-AUG-16:10 | 0.95 |
| September | 0.106522E+10 | 1.00 | 679.12 | 09-SEP-16:02 | 0.96 |
| October | 0.872362E+09 | 1.02 | 590.08 | 07-OCT-16:10 | 0.97 |
| November | 0.601686E+09 | 1.03 | 529.67 | 01-NOV-15:10 | 0.98 |
| December | 0.360923E+09 | 0.99 | 354.25 | 05-DEC-15:30 | 1.01 |
| Annual Sum or Average | 0.887372E+10 | 1.00 | |||
| Minimum of Months | 0.254353E+09 | 0.89 | 297.94 | 0.95 | |
| Maximum of Months | 0.126700E+10 | 1.03 | 771.61 | 1.02 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.63 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.150752E+09 | 0.76 | 224.51 | 29-JAN-17:10 | 1.03 |
| February | 0.216424E+09 | 0.89 | 322.76 | 07-FEB-16:20 | 1.02 |
| March | 0.375954E+09 | 1.00 | 414.97 | 27-MAR-16:04 | 1.01 |
| April | 0.561240E+09 | 1.03 | 511.90 | 28-APR-15:10 | 0.99 |
| May | 0.874092E+09 | 1.02 | 703.91 | 21-MAY-13:00 | 0.96 |
| June | 0.103516E+10 | 1.00 | 680.54 | 09-JUN-16:12 | 0.96 |
| July | 0.121591E+10 | 0.99 | 716.56 | 30-JUL-16:10 | 0.95 |
| August | 0.124436E+10 | 0.99 | 761.48 | 10-AUG-16:10 | 0.94 |
| September | 0.100398E+10 | 1.00 | 637.49 | 09-SEP-16:02 | 0.96 |
| October | 0.772452E+09 | 1.02 | 530.53 | 07-OCT-16:10 | 0.98 |
| November | 0.487370E+09 | 1.04 | 447.94 | 01-NOV-16:01 | 0.99 |
| December | 0.251715E+09 | 0.92 | 271.88 | 05-DEC-16:10 | 1.02 |
| Annual Sum or Average | 0.818941E+10 | 0.97 | |||
| Minimum of Months | 0.150752E+09 | 0.76 | 224.51 | 0.94 | |
| Maximum of Months | 0.124436E+10 | 1.04 | 761.48 | 1.03 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.255900E+09 | 0.90 | 294.98 | 29-JAN-11:50 | 1.02 |
| February | 0.298528E+09 | 0.97 | 393.22 | 05-FEB-14:00 | 1.01 |
| March | 0.432925E+09 | 1.02 | 462.59 | 27-MAR-11:30 | 1.00 |
| April | 0.597699E+09 | 1.03 | 515.44 | 28-APR-14:30 | 0.99 |
| May | 0.878891E+09 | 1.02 | 726.88 | 21-MAY-13:00 | 0.95 |
| June | 0.101972E+10 | 1.00 | 650.06 | 09-JUN-12:50 | 0.96 |
| July | 0.121187E+10 | 0.99 | 710.67 | 30-JUL-16:10 | 0.95 |
| August | 0.126204E+10 | 0.99 | 730.89 | 10-AUG-16:10 | 0.95 |
| September | 0.106094E+10 | 1.00 | 638.68 | 09-SEP-16:02 | 0.96 |
| October | 0.871155E+09 | 1.02 | 565.63 | 07-OCT-13:30 | 0.97 |
| November | 0.599956E+09 | 1.03 | 511.93 | 01-NOV-14:10 | 0.98 |
| December | 0.358092E+09 | 0.99 | 337.14 | 04-DEC-13:20 | 1.02 |
| Annual Sum or Average | 0.884772E+10 | 1.00 | |||
| Minimum of Months | 0.255900E+09 | 0.90 | 294.98 | 0.95 | |
| Maximum of Months | 0.126204E+10 | 1.03 | 730.89 | 1.02 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.63 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.151930E+09 | 0.77 | 216.97 | 29-JAN-12:00 | 1.03 |
| February | 0.215142E+09 | 0.90 | 291.85 | 07-FEB-16:20 | 1.02 |
| March | 0.370569E+09 | 1.00 | 422.53 | 27-MAR-11:00 | 1.01 |
| April | 0.563312E+09 | 1.03 | 495.47 | 28-APR-14:30 | 0.99 |
| May | 0.875860E+09 | 1.02 | 713.77 | 21-MAY-13:00 | 0.95 |
| June | 0.103056E+10 | 1.00 | 650.93 | 09-JUN-11:00 | 0.96 |
| July | 0.121055E+10 | 0.99 | 693.17 | 14-JUL-14:00 | 0.95 |
| August | 0.123932E+10 | 0.99 | 720.83 | 10-AUG-16:10 | 0.95 |
| September | 0.100003E+10 | 1.00 | 597.30 | 09-SEP-16:02 | 0.96 |
| October | 0.771995E+09 | 1.02 | 498.72 | 07-OCT-16:10 | 0.98 |
| November | 0.486384E+09 | 1.03 | 421.86 | 01-NOV-14:10 | 1.00 |
| December | 0.249119E+09 | 0.93 | 242.92 | 05-DEC-16:10 | 1.03 |
| Annual Sum or Average | 0.816476E+10 | 0.97 | |||
| Minimum of Months | 0.151930E+09 | 0.77 | 216.97 | 0.95 | |
| Maximum of Months | 0.123932E+10 | 1.03 | 720.83 | 1.03 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.159854E+09 | 0.93 | 175.88 | 29-JAN-17:10 | 1.04 |
| February | 0.207563E+09 | 1.00 | 243.27 | 07-FEB-17:02 | 1.02 |
| March | 0.328701E+09 | 1.03 | 305.50 | 27-MAR-11:00 | 1.02 |
| April | 0.469168E+09 | 1.03 | 368.20 | 28-APR-15:10 | 1.00 |
| May | 0.707208E+09 | 1.02 | 500.68 | 21-MAY-13:00 | 0.97 |
| June | 0.831079E+09 | 1.01 | 490.82 | 09-JUN-14:20 | 0.97 |
| July | 0.975666E+09 | 1.00 | 526.62 | 30-JUL-17:10 | 0.96 |
| August | 0.995593E+09 | 0.99 | 559.59 | 10-AUG-16:10 | 0.96 |
| September | 0.813445E+09 | 1.01 | 472.11 | 09-SEP-16:02 | 0.97 |
| October | 0.641015E+09 | 1.02 | 401.50 | 07-OCT-16:10 | 0.99 |
| November | 0.423027E+09 | 1.04 | 340.15 | 01-NOV-16:01 | 1.00 |
| December | 0.245211E+09 | 1.01 | 213.73 | 05-DEC-17:04 | 1.02 |
| Annual Sum or Average | 0.679753E+10 | 1.01 | |||
| Minimum of Months | 0.159854E+09 | 0.93 | 175.88 | 0.96 | |
| Maximum of Months | 0.995593E+09 | 1.04 | 559.59 | 1.04 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.160107E+09 | 0.93 | 175.66 | 29-JAN-17:10 | 1.04 |
| February | 0.207628E+09 | 1.00 | 242.75 | 07-FEB-17:02 | 1.02 |
| March | 0.328563E+09 | 1.03 | 306.28 | 27-MAR-11:00 | 1.02 |
| April | 0.469302E+09 | 1.03 | 368.30 | 28-APR-15:10 | 1.00 |
| May | 0.707368E+09 | 1.02 | 501.20 | 21-MAY-13:00 | 0.97 |
| June | 0.831029E+09 | 1.01 | 490.82 | 09-JUN-14:20 | 0.97 |
| July | 0.975607E+09 | 1.00 | 526.38 | 30-JUL-17:10 | 0.96 |
| August | 0.995548E+09 | 0.99 | 559.10 | 10-AUG-16:10 | 0.96 |
| September | 0.813414E+09 | 1.01 | 471.57 | 09-SEP-16:02 | 0.97 |
| October | 0.641085E+09 | 1.02 | 401.06 | 07-OCT-16:10 | 0.99 |
| November | 0.423058E+09 | 1.04 | 339.75 | 01-NOV-16:01 | 1.00 |
| December | 0.245207E+09 | 1.01 | 213.24 | 05-DEC-17:04 | 1.02 |
| Annual Sum or Average | 0.679792E+10 | 1.01 | |||
| Minimum of Months | 0.160107E+09 | 0.93 | 175.66 | 0.96 | |
| Maximum of Months | 0.995548E+09 | 1.04 | 559.10 | 1.04 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.267605E+09 | 1.02 | 254.26 | 28-JAN-14:00 | 1.03 |
| February | 0.292110E+09 | 1.03 | 329.83 | 05-FEB-14:00 | 1.01 |
| March | 0.391220E+09 | 1.03 | 356.92 | 01-MAR-15:10 | 1.01 |
| April | 0.503284E+09 | 1.03 | 385.13 | 28-APR-15:10 | 1.00 |
| May | 0.709529E+09 | 1.02 | 512.90 | 21-MAY-13:00 | 0.98 |
| June | 0.819214E+09 | 1.01 | 487.97 | 09-JUN-14:20 | 0.98 |
| July | 0.975983E+09 | 1.00 | 543.53 | 30-JUL-16:10 | 0.96 |
| August | 0.101764E+10 | 1.00 | 569.21 | 10-AUG-16:10 | 0.96 |
| September | 0.874341E+09 | 1.00 | 512.74 | 09-SEP-16:02 | 0.97 |
| October | 0.740406E+09 | 1.02 | 461.19 | 07-OCT-13:30 | 0.98 |
| November | 0.536615E+09 | 1.03 | 420.74 | 01-NOV-14:10 | 0.99 |
| December | 0.355036E+09 | 1.03 | 294.15 | 04-DEC-13:20 | 1.02 |
| Annual Sum or Average | 0.748298E+10 | 1.02 | |||
| Minimum of Months | 0.267605E+09 | 1.00 | 254.26 | 0.96 | |
| Maximum of Months | 0.101764E+10 | 1.03 | 569.21 | 1.03 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.267740E+09 | 1.02 | 254.65 | 28-JAN-14:00 | 1.03 |
| February | 0.292131E+09 | 1.03 | 330.17 | 05-FEB-14:00 | 1.01 |
| March | 0.391073E+09 | 1.03 | 356.82 | 01-MAR-15:10 | 1.01 |
| April | 0.503409E+09 | 1.03 | 385.23 | 28-APR-15:10 | 1.00 |
| May | 0.709692E+09 | 1.02 | 513.43 | 21-MAY-13:00 | 0.98 |
| June | 0.819171E+09 | 1.01 | 487.98 | 09-JUN-14:20 | 0.98 |
| July | 0.975929E+09 | 1.00 | 543.32 | 30-JUL-16:10 | 0.96 |
| August | 0.101759E+10 | 1.00 | 568.72 | 10-AUG-16:10 | 0.96 |
| September | 0.874295E+09 | 1.00 | 512.19 | 09-SEP-16:02 | 0.97 |
| October | 0.740445E+09 | 1.02 | 461.41 | 07-OCT-13:30 | 0.98 |
| November | 0.536613E+09 | 1.03 | 420.78 | 01-NOV-14:10 | 0.99 |
| December | 0.354990E+09 | 1.03 | 294.43 | 04-DEC-13:20 | 1.02 |
| Annual Sum or Average | 0.748308E+10 | 1.02 | |||
| Minimum of Months | 0.267740E+09 | 1.00 | 254.65 | 0.96 | |
| Maximum of Months | 0.101759E+10 | 1.03 | 568.72 | 1.03 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.61 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.61 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.61 |
| November | 0.103716E+09 | 0.62 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.61 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.63 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.63 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.63 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.63 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 99607596.86 | 0.60 | 181.51 | 29-JAN-16:10 | 1.02 |
| February | 0.132852E+09 | 0.69 | 258.29 | 05-FEB-15:00 | 1.00 |
| March | 0.216946E+09 | 0.86 | 316.93 | 01-MAR-15:30 | 0.99 |
| April | 0.320603E+09 | 0.99 | 347.03 | 28-APR-15:10 | 0.97 |
| May | 0.505931E+09 | 1.02 | 471.23 | 21-MAY-13:00 | 0.94 |
| June | 0.597565E+09 | 1.00 | 436.94 | 09-JUN-16:10 | 0.95 |
| July | 0.719953E+09 | 0.99 | 475.05 | 30-JUL-16:10 | 0.93 |
| August | 0.747065E+09 | 0.99 | 496.23 | 10-AUG-16:01 | 0.93 |
| September | 0.611454E+09 | 1.00 | 427.70 | 09-SEP-16:02 | 0.95 |
| October | 0.480655E+09 | 1.02 | 371.16 | 07-OCT-15:20 | 0.97 |
| November | 0.305472E+09 | 0.99 | 335.32 | 01-NOV-14:20 | 0.98 |
| December | 0.157721E+09 | 0.72 | 221.86 | 03-DEC-14:40 | 1.01 |
| Annual Sum or Average | 0.489583E+10 | 0.91 | |||
| Minimum of Months | 99607596.86 | 0.60 | 181.51 | 0.93 | |
| Maximum of Months | 0.747065E+09 | 1.02 | 496.23 | 1.02 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 50289006.63 | 0.51 | 137.22 | 29-JAN-16:10 | 1.03 |
| February | 91160256.77 | 0.64 | 204.12 | 07-FEB-16:10 | 1.01 |
| March | 0.184242E+09 | 0.84 | 278.96 | 01-MAR-15:30 | 1.00 |
| April | 0.302269E+09 | 0.99 | 335.10 | 28-APR-15:10 | 0.98 |
| May | 0.505000E+09 | 1.02 | 463.87 | 21-MAY-13:00 | 0.94 |
| June | 0.604220E+09 | 1.00 | 442.45 | 09-JUN-16:12 | 0.95 |
| July | 0.719938E+09 | 0.99 | 463.50 | 30-JUL-16:10 | 0.94 |
| August | 0.735259E+09 | 0.99 | 489.07 | 10-AUG-16:01 | 0.93 |
| September | 0.579090E+09 | 1.00 | 401.81 | 09-SEP-16:02 | 0.95 |
| October | 0.427484E+09 | 1.02 | 333.69 | 07-OCT-16:10 | 0.97 |
| November | 0.245170E+09 | 0.98 | 282.88 | 01-NOV-15:10 | 0.99 |
| December | 0.102858E+09 | 0.66 | 162.24 | 05-DEC-16:10 | 1.02 |
| Annual Sum or Average | 0.454698E+10 | 0.89 | |||
| Minimum of Months | 50289006.63 | 0.51 | 137.22 | 0.93 | |
| Maximum of Months | 0.735259E+09 | 1.02 | 489.07 | 1.03 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 99321691.71 | 0.61 | 178.30 | 29-JAN-12:00 | 1.02 |
| February | 0.131401E+09 | 0.69 | 250.31 | 05-FEB-14:00 | 1.00 |
| March | 0.213555E+09 | 0.87 | 302.77 | 27-MAR-12:40 | 0.99 |
| April | 0.321410E+09 | 0.99 | 342.51 | 28-APR-12:30 | 0.98 |
| May | 0.506054E+09 | 1.02 | 476.01 | 21-MAY-13:00 | 0.93 |
| June | 0.594021E+09 | 1.00 | 422.72 | 09-JUN-13:00 | 0.94 |
| July | 0.715234E+09 | 0.99 | 454.48 | 30-JUL-16:10 | 0.93 |
| August | 0.742307E+09 | 0.99 | 464.73 | 10-AUG-16:01 | 0.93 |
| September | 0.607837E+09 | 1.00 | 397.90 | 09-SEP-16:02 | 0.95 |
| October | 0.479272E+09 | 1.02 | 360.84 | 07-OCT-13:30 | 0.96 |
| November | 0.304262E+09 | 0.99 | 324.27 | 01-NOV-14:00 | 0.97 |
| December | 0.155619E+09 | 0.73 | 210.88 | 04-DEC-13:20 | 1.01 |
| Annual Sum or Average | 0.487029E+10 | 0.91 | |||
| Minimum of Months | 99321691.71 | 0.61 | 178.30 | 0.93 | |
| Maximum of Months | 0.742307E+09 | 1.02 | 476.01 | 1.02 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 49538520.94 | 0.52 | 131.20 | 29-JAN-12:00 | 1.03 |
| February | 89650120.24 | 0.64 | 184.30 | 05-FEB-15:10 | 1.02 |
| March | 0.181001E+09 | 0.85 | 270.36 | 27-MAR-11:40 | 1.00 |
| April | 0.303213E+09 | 0.99 | 326.84 | 28-APR-14:20 | 0.97 |
| May | 0.505009E+09 | 1.01 | 468.93 | 21-MAY-13:00 | 0.93 |
| June | 0.600431E+09 | 1.00 | 422.03 | 09-JUN-12:50 | 0.94 |
| July | 0.715018E+09 | 0.99 | 449.09 | 14-JUL-14:00 | 0.93 |
| August | 0.730465E+09 | 0.99 | 457.69 | 10-AUG-16:10 | 0.93 |
| September | 0.575764E+09 | 1.00 | 372.20 | 09-SEP-16:02 | 0.95 |
| October | 0.426683E+09 | 1.02 | 312.55 | 07-OCT-13:30 | 0.97 |
| November | 0.244448E+09 | 0.98 | 267.37 | 01-NOV-14:10 | 0.99 |
| December | 0.100666E+09 | 0.67 | 149.88 | 10-DEC-13:00 | 1.03 |
| Annual Sum or Average | 0.452189E+10 | 0.89 | |||
| Minimum of Months | 49538520.94 | 0.52 | 131.20 | 0.93 | |
| Maximum of Months | 0.730465E+09 | 1.02 | 468.93 | 1.03 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 46722997.49 | 0.57 | 103.69 | 29-JAN-16:10 | 1.04 |
| February | 81226813.76 | 0.71 | 149.41 | 07-FEB-16:10 | 1.02 |
| March | 0.157298E+09 | 0.89 | 203.02 | 27-MAR-13:00 | 1.01 |
| April | 0.253102E+09 | 1.01 | 245.99 | 28-APR-15:10 | 0.99 |
| May | 0.413743E+09 | 1.02 | 337.88 | 21-MAY-13:00 | 0.96 |
| June | 0.491026E+09 | 1.00 | 327.05 | 09-JUN-14:20 | 0.96 |
| July | 0.585221E+09 | 0.99 | 349.50 | 14-JUL-14:00 | 0.95 |
| August | 0.595676E+09 | 0.99 | 364.07 | 10-AUG-16:10 | 0.94 |
| September | 0.473331E+09 | 1.01 | 298.99 | 09-SEP-16:02 | 0.96 |
| October | 0.356212E+09 | 1.02 | 252.65 | 07-OCT-16:10 | 0.98 |
| November | 0.211006E+09 | 1.00 | 211.89 | 01-NOV-14:10 | 1.00 |
| December | 93967688.64 | 0.74 | 122.13 | 10-DEC-13:00 | 1.03 |
| Annual Sum or Average | 0.375853E+10 | 0.91 | |||
| Minimum of Months | 46722997.49 | 0.57 | 103.69 | 0.94 | |
| Maximum of Months | 0.595676E+09 | 1.02 | 364.07 | 1.04 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 46953389.07 | 0.57 | 103.47 | 29-JAN-16:10 | 1.04 |
| February | 81332185.03 | 0.71 | 148.87 | 07-FEB-16:10 | 1.02 |
| March | 0.157265E+09 | 0.89 | 203.56 | 27-MAR-13:00 | 1.01 |
| April | 0.253186E+09 | 1.01 | 245.91 | 28-APR-15:10 | 0.99 |
| May | 0.413793E+09 | 1.02 | 338.32 | 21-MAY-13:00 | 0.96 |
| June | 0.490930E+09 | 1.00 | 326.94 | 09-JUN-14:20 | 0.96 |
| July | 0.585086E+09 | 0.99 | 349.37 | 14-JUL-14:00 | 0.95 |
| August | 0.595545E+09 | 0.99 | 363.37 | 10-AUG-16:10 | 0.94 |
| September | 0.473251E+09 | 1.00 | 298.32 | 09-SEP-16:02 | 0.96 |
| October | 0.356230E+09 | 1.02 | 252.07 | 07-OCT-16:10 | 0.98 |
| November | 0.211050E+09 | 1.00 | 211.91 | 01-NOV-14:10 | 1.00 |
| December | 94046317.70 | 0.74 | 122.38 | 10-DEC-13:00 | 1.03 |
| Annual Sum or Average | 0.375867E+10 | 0.91 | |||
| Minimum of Months | 46953389.07 | 0.57 | 103.47 | 0.94 | |
| Maximum of Months | 0.595545E+09 | 1.02 | 363.37 | 1.04 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 98714986.96 | 0.66 | 151.85 | 28-JAN-14:00 | 1.03 |
| February | 0.124366E+09 | 0.76 | 212.32 | 05-FEB-14:00 | 1.00 |
| March | 0.190618E+09 | 0.90 | 239.78 | 01-MAR-15:10 | 1.00 |
| April | 0.271719E+09 | 1.01 | 261.14 | 28-APR-12:30 | 0.99 |
| May | 0.414931E+09 | 1.02 | 345.18 | 21-MAY-13:00 | 0.96 |
| June | 0.484543E+09 | 1.01 | 326.95 | 09-JUN-14:20 | 0.96 |
| July | 0.585493E+09 | 1.00 | 357.37 | 30-JUL-16:10 | 0.95 |
| August | 0.607878E+09 | 0.99 | 371.22 | 10-AUG-16:10 | 0.95 |
| September | 0.506235E+09 | 1.00 | 325.08 | 09-SEP-16:02 | 0.96 |
| October | 0.409934E+09 | 1.02 | 298.58 | 07-OCT-13:30 | 0.97 |
| November | 0.271982E+09 | 1.01 | 269.34 | 01-NOV-14:10 | 0.98 |
| December | 0.150704E+09 | 0.79 | 184.53 | 04-DEC-13:20 | 1.01 |
| Annual Sum or Average | 0.411712E+10 | 0.93 | |||
| Minimum of Months | 98714986.96 | 0.66 | 151.85 | 0.95 | |
| Maximum of Months | 0.607878E+09 | 1.02 | 371.22 | 1.03 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 98820521.97 | 0.66 | 152.30 | 28-JAN-14:00 | 1.03 |
| February | 0.124321E+09 | 0.76 | 212.44 | 05-FEB-14:00 | 1.00 |
| March | 0.190423E+09 | 0.90 | 239.33 | 01-MAR-15:10 | 1.00 |
| April | 0.271605E+09 | 1.01 | 261.86 | 28-APR-12:30 | 0.99 |
| May | 0.414715E+09 | 1.02 | 345.35 | 21-MAY-13:00 | 0.96 |
| June | 0.484172E+09 | 1.01 | 326.64 | 09-JUN-14:20 | 0.96 |
| July | 0.585044E+09 | 1.00 | 356.79 | 30-JUL-16:10 | 0.95 |
| August | 0.607418E+09 | 0.99 | 370.35 | 10-AUG-16:10 | 0.95 |
| September | 0.505855E+09 | 1.00 | 324.26 | 09-SEP-16:02 | 0.96 |
| October | 0.409666E+09 | 1.02 | 298.59 | 07-OCT-13:30 | 0.97 |
| November | 0.271779E+09 | 1.01 | 269.17 | 01-NOV-14:10 | 0.98 |
| December | 0.150610E+09 | 0.79 | 184.70 | 04-DEC-13:20 | 1.01 |
| Annual Sum or Average | 0.411443E+10 | 0.93 | |||
| Minimum of Months | 98820521.97 | 0.66 | 152.30 | 0.95 | |
| Maximum of Months | 0.607418E+09 | 1.02 | 370.35 | 1.03 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.61 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.61 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.61 |
| November | 51857908.47 | 0.62 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.61 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.63 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.63 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.63 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.63 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.657330E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.695485E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.924856E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.127996E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.205860E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.250861E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.311927E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.337240E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.283792E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.235154E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.164247E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.990072E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.224385E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.657330E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.337240E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.423381E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.509287E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.786823E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.120507E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.205995E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.254563E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.312731E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.332705E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.269951E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.212603E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.138781E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.749411E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209473E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.423381E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.332705E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.191957E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.180691E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.210799E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.216998E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.276005E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.301257E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.345769E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.374069E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.318196E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.290337E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.237566E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.204917E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.314856E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.180691E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.374069E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.427070E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.507529E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.776550E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.121269E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.206971E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.254120E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.312227E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.332240E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.269516E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.212764E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.138657E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.744514E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209333E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.427070E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.332240E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.416293E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.485828E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.714144E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.105503E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.173755E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.212371E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.259719E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.273765E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.223193E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.177319E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.118007E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.681726E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.177343E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.416293E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.273765E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.416645E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.485951E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.713793E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.105547E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.173817E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.212376E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.259726E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.273776E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.223201E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.177347E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.118018E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.681657E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.177361E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.416645E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.273776E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.662360E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.681251E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.860329E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.113659E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.174293E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.209248E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.259588E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.279078E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.237993E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.200967E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.144535E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.931810E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.193294E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.662360E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.279078E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.729664E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.745905E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.937479E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.123526E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.186896E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.221860E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.273577E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.292718E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.251078E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.213983E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.155832E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.101820E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.206259E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.729664E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.292718E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.119588E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.142458E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.209854E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.291426E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.444775E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.530696E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.642324E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.671372E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.552262E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.438273E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.293312E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.171266E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.450760E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.119588E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.671372E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.710500E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.103038E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.180288E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.274893E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.443875E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.537036E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.642498E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.660396E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.521558E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.388885E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.238105E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.119772E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.418139E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.710500E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.660396E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.120698E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.142221E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.207854E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.293317E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.447131E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.530140E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.641672E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.670864E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.551740E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.439001E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.293359E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.170462E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.450846E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.120698E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.670864E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.718402E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.102765E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.178317E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.276823E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.446172E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.536368E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.641743E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.659856E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.521149E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.389866E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.238362E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.118922E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.418219E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.718402E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.659856E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.760063E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.995974E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.158852E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.231551E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.362267E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.435152E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.520701E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.533704E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.426454E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.325481E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.208247E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.117620E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.349563E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.760063E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.533704E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.761331E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.996381E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.158801E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.231641E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.362383E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.435167E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.520717E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.533729E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.426477E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.325547E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.208283E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.117629E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.349615E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.761331E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.533729E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.126909E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.139807E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.188631E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.248028E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.362930E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.428424E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.520189E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.544528E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.457300E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.375070E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.263570E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.169825E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.382521E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.126909E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.544528E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.126984E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.139830E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.188578E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.248114E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.363047E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.428441E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.520207E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.544553E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.457318E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.375125E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.263594E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.169819E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.382561E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.126984E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.544553E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.466587E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.630047E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.103763E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.156871E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.256092E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.308712E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.378265E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.394035E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.316079E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.241134E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.148963E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.747043E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.248828E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.466587E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.394035E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.235712E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.433592E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.883035E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.148022E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.255793E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.312311E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.378486E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.388193E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.299777E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.214789E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.119797E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.488762E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.232128E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.235712E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.388193E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.467148E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.625752E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.102579E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.157910E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.257163E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.308113E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.377318E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.393126E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.315453E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.241374E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.148946E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.740100E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.248528E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.467148E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.393126E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.233260E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.428283E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.871362E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.149106E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.256827E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.311629E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.377470E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.387275E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.299260E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.215235E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.119915E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.480395E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.231805E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.233260E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.387275E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.220735E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.388166E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.757198E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.124435E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.210584E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.255093E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.309384E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.316267E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.246254E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.179821E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.103503E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.448627E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.192681E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.220735E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.316267E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.221860E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.388740E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.757188E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.124501E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.210647E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.255090E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.309369E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.316255E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.246257E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.179863E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.103544E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.449083E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.192721E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.221860E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.316255E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.464889E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.592464E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.915496E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.133461E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.210995E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.251541E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.309269E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.322326E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.262911E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.206576E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.133138E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.717074E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209921E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.464889E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.322326E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.465476E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.592376E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.914780E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.133440E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.210943E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.251416E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.309117E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.322171E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.262782E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.206494E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.133071E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.716772E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209837E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.465476E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.322171E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.139888E+09 | 0.204798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.146588E+09 | 0.216234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.193296E+09 | 0.281635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.261750E+09 | 0.383514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.406325E+09 | 0.593421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.484997E+09 | 0.726017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.592554E+09 | 0.889898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.638880E+09 | 0.964659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.549590E+09 | 0.836275E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.469784E+09 | 0.707102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.338175E+09 | 0.506508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.208990E+09 | 0.310910E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.443082E+10 | 0.662097E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.139888E+09 | 0.204798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.638880E+09 | 0.964659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 89929783.99 | 0.131538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107107E+09 | 0.157935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.164111E+09 | 0.239039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.246156E+09 | 0.361029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.406228E+09 | 0.594871E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491826E+09 | 0.738565E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.593634E+09 | 0.894261E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.629549E+09 | 0.953296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.521929E+09 | 0.795712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.424019E+09 | 0.638591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.285264E+09 | 0.426858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.157868E+09 | 0.234719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.411762E+10 | 0.616641E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 89929783.99 | 0.131538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.629549E+09 | 0.953296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.148196E+10 | 0.178295E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.133855E+10 | 0.189113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.148196E+10 | 0.245077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.143416E+10 | 0.279834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.148196E+10 | 0.463649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.143416E+10 | 0.575045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.148196E+10 | 0.713330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.148196E+10 | 0.817887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.143416E+10 | 0.651794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.148196E+10 | 0.546904E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143416E+10 | 0.374823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.148196E+10 | 0.232597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.174489E+11 | 0.526835E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.133855E+10 | 0.178295E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.148196E+10 | 0.817887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 90450370.90 | 0.132826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.106423E+09 | 0.157558E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.161461E+09 | 0.236105E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.246969E+09 | 0.363786E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.406973E+09 | 0.598919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.489520E+09 | 0.739056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.590910E+09 | 0.895241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.626791E+09 | 0.954699E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.519569E+09 | 0.796410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.423121E+09 | 0.640672E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.284195E+09 | 0.427344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156382E+09 | 0.233481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.410276E+10 | 0.617610E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 90450370.90 | 0.132826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.626791E+09 | 0.954699E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 87533752.89 | 0.129760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101227E+09 | 0.151391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.147632E+09 | 0.218213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.213623E+09 | 0.318011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.339233E+09 | 0.504237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.405963E+09 | 0.618672E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.487382E+09 | 0.745332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.511948E+09 | 0.786578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.426784E+09 | 0.660422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.349941E+09 | 0.535215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.240181E+09 | 0.364728E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.142198E+09 | 0.214453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.345365E+10 | 0.524701E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 87533752.89 | 0.129760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.511948E+09 | 0.786578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 87600738.47 | 0.129875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101244E+09 | 0.151434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.147545E+09 | 0.218108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.213695E+09 | 0.318155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.339326E+09 | 0.504441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.405938E+09 | 0.618719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.487353E+09 | 0.745397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.511926E+09 | 0.786662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.426763E+09 | 0.660481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.349966E+09 | 0.535328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.240184E+09 | 0.364781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.142171E+09 | 0.214438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.345371E+10 | 0.524782E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 87600738.47 | 0.129875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.511926E+09 | 0.786662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.139560E+09 | 0.207188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.142260E+09 | 0.212861E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.178234E+09 | 0.263500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.230433E+09 | 0.342578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.340671E+09 | 0.504721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.400337E+09 | 0.607792E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.487608E+09 | 0.742867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.522657E+09 | 0.800130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.455992E+09 | 0.703752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.397403E+09 | 0.607127E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.294726E+09 | 0.447954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.194781E+09 | 0.294022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.378466E+10 | 0.573449E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.139560E+09 | 0.207188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.522657E+09 | 0.800130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.153866E+09 | 0.228426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.155930E+09 | 0.233342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194469E+09 | 0.287665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.250849E+09 | 0.373262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.365981E+09 | 0.542724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.425300E+09 | 0.645837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.514917E+09 | 0.784494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.549281E+09 | 0.840928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.481984E+09 | 0.743996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.423871E+09 | 0.647997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.318273E+09 | 0.484073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.213059E+09 | 0.321675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.404778E+10 | 0.613442E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.153866E+09 | 0.228426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.549281E+09 | 0.840928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.254353E+09 | 0.372756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.299983E+09 | 0.443045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.438544E+09 | 0.640263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.595766E+09 | 0.875387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.876940E+09 | 0.128293E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.102399E+10 | 0.153668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121695E+10 | 0.183171E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.126700E+10 | 0.191631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.106522E+10 | 0.162230E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.872362E+09 | 0.131090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.601686E+09 | 0.899681E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.360923E+09 | 0.537068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.887372E+10 | 0.132690E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.254353E+09 | 0.372756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.126700E+10 | 0.191631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.150752E+09 | 0.220778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.216424E+09 | 0.319555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.375954E+09 | 0.548754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.561240E+09 | 0.825764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.874092E+09 | 0.128271E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103516E+10 | 0.155894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121591E+10 | 0.183641E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.124436E+10 | 0.188815E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.100398E+10 | 0.153282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.772452E+09 | 0.116238E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.487370E+09 | 0.728609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.251715E+09 | 0.374597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.818941E+10 | 0.122795E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.150752E+09 | 0.220778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.124436E+10 | 0.188815E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.255900E+09 | 0.376725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.298528E+09 | 0.442936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.432925E+09 | 0.634882E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.597699E+09 | 0.882458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.878891E+09 | 0.129253E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.101972E+10 | 0.153897E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121187E+10 | 0.183497E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.126204E+10 | 0.192051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.106094E+10 | 0.162497E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.871155E+09 | 0.131666E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.599956E+09 | 0.901899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.358092E+09 | 0.535311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.884772E+10 | 0.133028E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.255900E+09 | 0.376725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.126204E+10 | 0.192051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.151930E+09 | 0.223464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.215142E+09 | 0.319058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.370569E+09 | 0.543274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.563312E+09 | 0.832809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.875860E+09 | 0.129229E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103056E+10 | 0.156120E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121055E+10 | 0.183964E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.123932E+10 | 0.189235E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.100003E+10 | 0.153550E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.771995E+09 | 0.116832E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.486384E+09 | 0.730923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.249119E+09 | 0.372374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.816476E+10 | 0.123112E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.151930E+09 | 0.223464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.123932E+10 | 0.189235E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.159854E+09 | 0.236863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.207563E+09 | 0.310324E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.328701E+09 | 0.485841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.469168E+09 | 0.698808E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.707208E+09 | 0.105042E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.831079E+09 | 0.126629E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975666E+09 | 0.149137E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.995593E+09 | 0.152842E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.813445E+09 | 0.125734E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.641015E+09 | 0.977810E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.423027E+09 | 0.640725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.245211E+09 | 0.369411E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.679753E+10 | 0.103136E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.159854E+09 | 0.236863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.995593E+09 | 0.152842E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.160107E+09 | 0.237267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.207628E+09 | 0.310459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.328563E+09 | 0.485694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.469302E+09 | 0.699098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.707368E+09 | 0.105080E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.831029E+09 | 0.126640E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975607E+09 | 0.149151E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.995548E+09 | 0.152859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.813414E+09 | 0.125747E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.641085E+09 | 0.978057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.423058E+09 | 0.640860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.245207E+09 | 0.369450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.679792E+10 | 0.103157E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.160107E+09 | 0.237267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.995548E+09 | 0.152859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.267605E+09 | 0.396978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.292110E+09 | 0.436783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.391220E+09 | 0.578233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.503284E+09 | 0.748282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.709529E+09 | 0.105000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.819214E+09 | 0.124310E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975983E+09 | 0.148580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101764E+10 | 0.155608E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.874341E+09 | 0.134700E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.740406E+09 | 0.112707E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.536615E+09 | 0.812774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.355036E+09 | 0.534963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.748298E+10 | 0.113171E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.267605E+09 | 0.396978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101764E+10 | 0.155608E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.267740E+09 | 0.397234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.292131E+09 | 0.436874E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.391073E+09 | 0.578088E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.503409E+09 | 0.748566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.709692E+09 | 0.105038E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.819171E+09 | 0.124321E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975929E+09 | 0.148594E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101759E+10 | 0.155625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.874295E+09 | 0.134713E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.740445E+09 | 0.112730E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.536613E+09 | 0.812891E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.354990E+09 | 0.534967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.748308E+10 | 0.113188E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.267740E+09 | 0.397234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101759E+10 | 0.155625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 99607596.86 | 0.145348E+10 | 45978.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132852E+09 | 0.195119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.216946E+09 | 0.315008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.320603E+09 | 0.468435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.505931E+09 | 0.736249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.597565E+09 | 0.892300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.719953E+09 | 0.107849E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.747065E+09 | 0.112498E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.611454E+09 | 0.926641E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.480655E+09 | 0.717910E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.305472E+09 | 0.454344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.157721E+09 | 0.233652E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.489583E+10 | 0.728848E+11 | 45978.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 99607596.86 | 0.145348E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.747065E+09 | 0.112498E+11 | 45978.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 50289006.63 | 0.731376E+09 | 2927401.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 91160256.77 | 0.133626E+10 | 26540.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.184242E+09 | 0.266976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.302269E+09 | 0.441662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.505000E+09 | 0.736417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.604220E+09 | 0.904583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.719938E+09 | 0.108100E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.735259E+09 | 0.110937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.579090E+09 | 0.878447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.427484E+09 | 0.638283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.245170E+09 | 0.363923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.102858E+09 | 0.152206E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.454698E+10 | 0.677964E+11 | 2953942.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50289006.63 | 0.731376E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.735259E+09 | 0.110937E+11 | 2927401.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 99321691.71 | 0.145788E+10 | 73931.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.131401E+09 | 0.194147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.213555E+09 | 0.311896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.321410E+09 | 0.472669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.506054E+09 | 0.741738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.594021E+09 | 0.893952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.715234E+09 | 0.108031E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.742307E+09 | 0.112733E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.607837E+09 | 0.928322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.479272E+09 | 0.721383E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.304262E+09 | 0.455760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.155619E+09 | 0.231921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.487029E+10 | 0.730522E+11 | 73931.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 99321691.71 | 0.145788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.742307E+09 | 0.112733E+11 | 73931.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 49538520.94 | 0.724741E+09 | 2495656.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 89650120.24 | 0.132141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.181001E+09 | 0.263761E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.303213E+09 | 0.445896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.505009E+09 | 0.741908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.600431E+09 | 0.906222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.715018E+09 | 0.108281E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.730465E+09 | 0.111173E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.575764E+09 | 0.880155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.426683E+09 | 0.641883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.244448E+09 | 0.365305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.100666E+09 | 0.149806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.452189E+10 | 0.679409E+11 | 2495656.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 49538520.94 | 0.724741E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.730465E+09 | 0.111173E+11 | 2495656.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 46722997.49 | 0.686753E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81226813.76 | 0.120011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.157298E+09 | 0.229505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.253102E+09 | 0.372126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.413743E+09 | 0.606972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491026E+09 | 0.738841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585221E+09 | 0.883270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.595676E+09 | 0.902993E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473331E+09 | 0.721964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.356212E+09 | 0.535845E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.211006E+09 | 0.315521E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 93967688.64 | 0.140105E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.375853E+10 | 0.563583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46722997.49 | 0.686753E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.595676E+09 | 0.902993E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 46953389.07 | 0.690273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81332185.03 | 0.120194E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.157265E+09 | 0.229515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.253186E+09 | 0.372353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.413793E+09 | 0.607232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.490930E+09 | 0.738943E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585086E+09 | 0.883375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.595545E+09 | 0.903115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473251E+09 | 0.722073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.356230E+09 | 0.536039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.211050E+09 | 0.315677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 94046317.70 | 0.140255E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.375867E+10 | 0.563780E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46953389.07 | 0.690273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.595545E+09 | 0.903115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 98714986.96 | 0.145187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.124366E+09 | 0.184068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190618E+09 | 0.278664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.271719E+09 | 0.399343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.414931E+09 | 0.607080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.484543E+09 | 0.726754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585493E+09 | 0.881035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.607878E+09 | 0.919056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.506235E+09 | 0.770875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.409934E+09 | 0.616516E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.271982E+09 | 0.407457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.150704E+09 | 0.224975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.411712E+10 | 0.616101E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 98714986.96 | 0.145187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.607878E+09 | 0.919056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 98820521.97 | 0.145395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.124321E+09 | 0.184070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190423E+09 | 0.278483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.271605E+09 | 0.399340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.414715E+09 | 0.607042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.484172E+09 | 0.726539E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585044E+09 | 0.880798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.607418E+09 | 0.918826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.505855E+09 | 0.770662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.409666E+09 | 0.616404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.271779E+09 | 0.407333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.150610E+09 | 0.224918E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.411443E+10 | 0.615981E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 98820521.97 | 0.145395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.607418E+09 | 0.918826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.139888E+09 | 0.00 | 0.00 | 0.00 | 0.517441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.146588E+09 | 0.00 | 0.00 | 0.00 | 0.548897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.193296E+09 | 0.00 | 0.00 | 0.00 | 0.731561E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.261750E+09 | 0.00 | 0.00 | 0.00 | 0.101821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.406325E+09 | 0.00 | 0.00 | 0.00 | 0.165227E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.484997E+09 | 0.00 | 0.00 | 0.00 | 0.202361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.592554E+09 | 0.00 | 0.00 | 0.00 | 0.252671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.638880E+09 | 0.00 | 0.00 | 0.00 | 0.273352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.549590E+09 | 0.00 | 0.00 | 0.00 | 0.228833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.469784E+09 | 0.00 | 0.00 | 0.00 | 0.188175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.338175E+09 | 0.00 | 0.00 | 0.00 | 0.130430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.208990E+09 | 0.00 | 0.00 | 0.00 | 0.781082E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.443082E+10 | 0.00 | 0.00 | 0.00 | 0.180077E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.139888E+09 | 0.00 | 0.00 | 0.00 | 0.517441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.638880E+09 | 0.00 | 0.00 | 0.00 | 0.273352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 89929783.99 | 0.00 | 0.00 | 0.00 | 0.333452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107107E+09 | 0.00 | 0.00 | 0.00 | 0.402180E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.164111E+09 | 0.00 | 0.00 | 0.00 | 0.622712E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.246156E+09 | 0.00 | 0.00 | 0.00 | 0.958915E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.406228E+09 | 0.00 | 0.00 | 0.00 | 0.165373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491826E+09 | 0.00 | 0.00 | 0.00 | 0.205380E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.593634E+09 | 0.00 | 0.00 | 0.00 | 0.253368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.629549E+09 | 0.00 | 0.00 | 0.00 | 0.269750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.521929E+09 | 0.00 | 0.00 | 0.00 | 0.217758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.424019E+09 | 0.00 | 0.00 | 0.00 | 0.170201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.285264E+09 | 0.00 | 0.00 | 0.00 | 0.110255E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.157868E+09 | 0.00 | 0.00 | 0.00 | 0.591543E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.411762E+10 | 0.00 | 0.00 | 0.00 | 0.168296E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 89929783.99 | 0.00 | 0.00 | 0.00 | 0.333452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.629549E+09 | 0.00 | 0.00 | 0.00 | 0.269750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.437613E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.133855E+10 | 0.00 | 0.00 | 0.00 | 0.468365E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.626026E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.143416E+10 | 0.00 | 0.00 | 0.00 | 0.735823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.127809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.143416E+10 | 0.00 | 0.00 | 0.00 | 0.157841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.197573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.225873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.143416E+10 | 0.00 | 0.00 | 0.00 | 0.174781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.142141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143416E+10 | 0.00 | 0.00 | 0.00 | 0.941509E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.567213E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.174489E+11 | 0.00 | 0.00 | 0.00 | 0.140367E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.133855E+10 | 0.00 | 0.00 | 0.00 | 0.437613E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.148196E+10 | 0.00 | 0.00 | 0.00 | 0.225873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 90450370.90 | 0.00 | 0.00 | 0.00 | 0.336619E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.106423E+09 | 0.00 | 0.00 | 0.00 | 0.401105E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.161461E+09 | 0.00 | 0.00 | 0.00 | 0.615089E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.246969E+09 | 0.00 | 0.00 | 0.00 | 0.965723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.406973E+09 | 0.00 | 0.00 | 0.00 | 0.166273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.489520E+09 | 0.00 | 0.00 | 0.00 | 0.205168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.590910E+09 | 0.00 | 0.00 | 0.00 | 0.253136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.626791E+09 | 0.00 | 0.00 | 0.00 | 0.269561E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.519569E+09 | 0.00 | 0.00 | 0.00 | 0.217559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.423121E+09 | 0.00 | 0.00 | 0.00 | 0.170452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.284195E+09 | 0.00 | 0.00 | 0.00 | 0.110238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156382E+09 | 0.00 | 0.00 | 0.00 | 0.588132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.410276E+10 | 0.00 | 0.00 | 0.00 | 0.168305E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 90450370.90 | 0.00 | 0.00 | 0.00 | 0.336619E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.626791E+09 | 0.00 | 0.00 | 0.00 | 0.269561E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 87533752.89 | 0.00 | 0.00 | 0.00 | 0.328759E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101227E+09 | 0.00 | 0.00 | 0.00 | 0.384600E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.147632E+09 | 0.00 | 0.00 | 0.00 | 0.566511E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.213623E+09 | 0.00 | 0.00 | 0.00 | 0.841404E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.339233E+09 | 0.00 | 0.00 | 0.00 | 0.139832E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.405963E+09 | 0.00 | 0.00 | 0.00 | 0.171774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.487382E+09 | 0.00 | 0.00 | 0.00 | 0.210981E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.511948E+09 | 0.00 | 0.00 | 0.00 | 0.222570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.426784E+09 | 0.00 | 0.00 | 0.00 | 0.180515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.349941E+09 | 0.00 | 0.00 | 0.00 | 0.142325E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.240181E+09 | 0.00 | 0.00 | 0.00 | 0.939886E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.142198E+09 | 0.00 | 0.00 | 0.00 | 0.539528E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.345365E+10 | 0.00 | 0.00 | 0.00 | 0.142807E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 87533752.89 | 0.00 | 0.00 | 0.00 | 0.328759E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.511948E+09 | 0.00 | 0.00 | 0.00 | 0.222570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 87600738.47 | 0.00 | 0.00 | 0.00 | 0.329045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101244E+09 | 0.00 | 0.00 | 0.00 | 0.384707E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.147545E+09 | 0.00 | 0.00 | 0.00 | 0.566248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.213695E+09 | 0.00 | 0.00 | 0.00 | 0.841780E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.339326E+09 | 0.00 | 0.00 | 0.00 | 0.139885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.405938E+09 | 0.00 | 0.00 | 0.00 | 0.171782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.487353E+09 | 0.00 | 0.00 | 0.00 | 0.210990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.511926E+09 | 0.00 | 0.00 | 0.00 | 0.222583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.426763E+09 | 0.00 | 0.00 | 0.00 | 0.180525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.349966E+09 | 0.00 | 0.00 | 0.00 | 0.142350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.240184E+09 | 0.00 | 0.00 | 0.00 | 0.940001E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.142171E+09 | 0.00 | 0.00 | 0.00 | 0.539486E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.345371E+10 | 0.00 | 0.00 | 0.00 | 0.142824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 87600738.47 | 0.00 | 0.00 | 0.00 | 0.329045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.511926E+09 | 0.00 | 0.00 | 0.00 | 0.222583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.139560E+09 | 0.00 | 0.00 | 0.00 | 0.522800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.142260E+09 | 0.00 | 0.00 | 0.00 | 0.538991E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.178234E+09 | 0.00 | 0.00 | 0.00 | 0.682095E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.230433E+09 | 0.00 | 0.00 | 0.00 | 0.906156E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.340671E+09 | 0.00 | 0.00 | 0.00 | 0.140226E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.400337E+09 | 0.00 | 0.00 | 0.00 | 0.169214E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.487608E+09 | 0.00 | 0.00 | 0.00 | 0.210827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.522657E+09 | 0.00 | 0.00 | 0.00 | 0.226813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.455992E+09 | 0.00 | 0.00 | 0.00 | 0.192394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.397403E+09 | 0.00 | 0.00 | 0.00 | 0.161227E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.294726E+09 | 0.00 | 0.00 | 0.00 | 0.115063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.194781E+09 | 0.00 | 0.00 | 0.00 | 0.737028E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.378466E+10 | 0.00 | 0.00 | 0.00 | 0.155447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.139560E+09 | 0.00 | 0.00 | 0.00 | 0.522800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.522657E+09 | 0.00 | 0.00 | 0.00 | 0.226813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.153866E+09 | 0.00 | 0.00 | 0.00 | 0.575797E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.155930E+09 | 0.00 | 0.00 | 0.00 | 0.589976E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194469E+09 | 0.00 | 0.00 | 0.00 | 0.743011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.250849E+09 | 0.00 | 0.00 | 0.00 | 0.984406E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.365981E+09 | 0.00 | 0.00 | 0.00 | 0.150298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.425300E+09 | 0.00 | 0.00 | 0.00 | 0.179330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.514917E+09 | 0.00 | 0.00 | 0.00 | 0.222085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.549281E+09 | 0.00 | 0.00 | 0.00 | 0.237790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.481984E+09 | 0.00 | 0.00 | 0.00 | 0.202879E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.423871E+09 | 0.00 | 0.00 | 0.00 | 0.171596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.318273E+09 | 0.00 | 0.00 | 0.00 | 0.124004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.213059E+09 | 0.00 | 0.00 | 0.00 | 0.805140E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.404778E+10 | 0.00 | 0.00 | 0.00 | 0.165781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.153866E+09 | 0.00 | 0.00 | 0.00 | 0.575797E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.549281E+09 | 0.00 | 0.00 | 0.00 | 0.237790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.254353E+09 | 0.00 | 0.00 | 0.00 | 0.941525E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.299983E+09 | 0.00 | 0.00 | 0.00 | 0.112460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.438544E+09 | 0.00 | 0.00 | 0.00 | 0.166000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.595766E+09 | 0.00 | 0.00 | 0.00 | 0.231849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.876940E+09 | 0.00 | 0.00 | 0.00 | 0.357081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.102399E+10 | 0.00 | 0.00 | 0.00 | 0.428297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121695E+10 | 0.00 | 0.00 | 0.00 | 0.520629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.126700E+10 | 0.00 | 0.00 | 0.00 | 0.544671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.106522E+10 | 0.00 | 0.00 | 0.00 | 0.445740E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.872362E+09 | 0.00 | 0.00 | 0.00 | 0.351037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.601686E+09 | 0.00 | 0.00 | 0.00 | 0.233143E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.360923E+09 | 0.00 | 0.00 | 0.00 | 0.135173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.887372E+10 | 0.00 | 0.00 | 0.00 | 0.362023E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.254353E+09 | 0.00 | 0.00 | 0.00 | 0.941525E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.126700E+10 | 0.00 | 0.00 | 0.00 | 0.544671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.150752E+09 | 0.00 | 0.00 | 0.00 | 0.559748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.216424E+09 | 0.00 | 0.00 | 0.00 | 0.813952E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.375954E+09 | 0.00 | 0.00 | 0.00 | 0.142693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.561240E+09 | 0.00 | 0.00 | 0.00 | 0.218769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.874092E+09 | 0.00 | 0.00 | 0.00 | 0.356466E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103516E+10 | 0.00 | 0.00 | 0.00 | 0.433520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121591E+10 | 0.00 | 0.00 | 0.00 | 0.520907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.124436E+10 | 0.00 | 0.00 | 0.00 | 0.535959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.100398E+10 | 0.00 | 0.00 | 0.00 | 0.421160E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.772452E+09 | 0.00 | 0.00 | 0.00 | 0.311640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.487370E+09 | 0.00 | 0.00 | 0.00 | 0.189368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.251715E+09 | 0.00 | 0.00 | 0.00 | 0.946008E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.818941E+10 | 0.00 | 0.00 | 0.00 | 0.336245E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.150752E+09 | 0.00 | 0.00 | 0.00 | 0.559748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.124436E+10 | 0.00 | 0.00 | 0.00 | 0.535959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.255900E+09 | 0.00 | 0.00 | 0.00 | 0.951081E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.298528E+09 | 0.00 | 0.00 | 0.00 | 0.112368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.432925E+09 | 0.00 | 0.00 | 0.00 | 0.164562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.597699E+09 | 0.00 | 0.00 | 0.00 | 0.233547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.878891E+09 | 0.00 | 0.00 | 0.00 | 0.359242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.101972E+10 | 0.00 | 0.00 | 0.00 | 0.428168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121187E+10 | 0.00 | 0.00 | 0.00 | 0.520485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.126204E+10 | 0.00 | 0.00 | 0.00 | 0.544660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.106094E+10 | 0.00 | 0.00 | 0.00 | 0.445646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.871155E+09 | 0.00 | 0.00 | 0.00 | 0.351885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.599956E+09 | 0.00 | 0.00 | 0.00 | 0.233364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.358092E+09 | 0.00 | 0.00 | 0.00 | 0.134652E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.884772E+10 | 0.00 | 0.00 | 0.00 | 0.362369E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.255900E+09 | 0.00 | 0.00 | 0.00 | 0.951081E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.126204E+10 | 0.00 | 0.00 | 0.00 | 0.544660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.151930E+09 | 0.00 | 0.00 | 0.00 | 0.566472E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.215142E+09 | 0.00 | 0.00 | 0.00 | 0.812511E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.370569E+09 | 0.00 | 0.00 | 0.00 | 0.141260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.563312E+09 | 0.00 | 0.00 | 0.00 | 0.220492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.875860E+09 | 0.00 | 0.00 | 0.00 | 0.358586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103056E+10 | 0.00 | 0.00 | 0.00 | 0.433313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.121055E+10 | 0.00 | 0.00 | 0.00 | 0.520688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.123932E+10 | 0.00 | 0.00 | 0.00 | 0.535925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.100003E+10 | 0.00 | 0.00 | 0.00 | 0.421146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.771995E+09 | 0.00 | 0.00 | 0.00 | 0.312667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.486384E+09 | 0.00 | 0.00 | 0.00 | 0.189723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.249119E+09 | 0.00 | 0.00 | 0.00 | 0.940106E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.816476E+10 | 0.00 | 0.00 | 0.00 | 0.336571E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.151930E+09 | 0.00 | 0.00 | 0.00 | 0.566472E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.123932E+10 | 0.00 | 0.00 | 0.00 | 0.535925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.159854E+09 | 0.00 | 0.00 | 0.00 | 0.600209E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.207563E+09 | 0.00 | 0.00 | 0.00 | 0.788411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.328701E+09 | 0.00 | 0.00 | 0.00 | 0.125982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.469168E+09 | 0.00 | 0.00 | 0.00 | 0.184634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.707208E+09 | 0.00 | 0.00 | 0.00 | 0.291546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.831079E+09 | 0.00 | 0.00 | 0.00 | 0.352044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975666E+09 | 0.00 | 0.00 | 0.00 | 0.423135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.995593E+09 | 0.00 | 0.00 | 0.00 | 0.434145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.813445E+09 | 0.00 | 0.00 | 0.00 | 0.345110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.641015E+09 | 0.00 | 0.00 | 0.00 | 0.261379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.423027E+09 | 0.00 | 0.00 | 0.00 | 0.165944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.245211E+09 | 0.00 | 0.00 | 0.00 | 0.930987E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.679753E+10 | 0.00 | 0.00 | 0.00 | 0.281588E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.159854E+09 | 0.00 | 0.00 | 0.00 | 0.600209E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.995593E+09 | 0.00 | 0.00 | 0.00 | 0.434145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.160107E+09 | 0.00 | 0.00 | 0.00 | 0.601224E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.207628E+09 | 0.00 | 0.00 | 0.00 | 0.788752E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.328563E+09 | 0.00 | 0.00 | 0.00 | 0.125945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.469302E+09 | 0.00 | 0.00 | 0.00 | 0.184711E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.707368E+09 | 0.00 | 0.00 | 0.00 | 0.291646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.831029E+09 | 0.00 | 0.00 | 0.00 | 0.352064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975607E+09 | 0.00 | 0.00 | 0.00 | 0.423156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.995548E+09 | 0.00 | 0.00 | 0.00 | 0.434175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.813414E+09 | 0.00 | 0.00 | 0.00 | 0.345136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.641085E+09 | 0.00 | 0.00 | 0.00 | 0.261439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.423058E+09 | 0.00 | 0.00 | 0.00 | 0.165977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.245207E+09 | 0.00 | 0.00 | 0.00 | 0.931079E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.679792E+10 | 0.00 | 0.00 | 0.00 | 0.281635E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.160107E+09 | 0.00 | 0.00 | 0.00 | 0.601224E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.995548E+09 | 0.00 | 0.00 | 0.00 | 0.434175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.267605E+09 | 0.00 | 0.00 | 0.00 | 0.100148E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.292110E+09 | 0.00 | 0.00 | 0.00 | 0.110596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.391220E+09 | 0.00 | 0.00 | 0.00 | 0.149509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.503284E+09 | 0.00 | 0.00 | 0.00 | 0.197700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.709529E+09 | 0.00 | 0.00 | 0.00 | 0.291977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.819214E+09 | 0.00 | 0.00 | 0.00 | 0.346502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975983E+09 | 0.00 | 0.00 | 0.00 | 0.422591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101764E+10 | 0.00 | 0.00 | 0.00 | 0.442764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.874341E+09 | 0.00 | 0.00 | 0.00 | 0.369866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.740406E+09 | 0.00 | 0.00 | 0.00 | 0.301030E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.536615E+09 | 0.00 | 0.00 | 0.00 | 0.209909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.355036E+09 | 0.00 | 0.00 | 0.00 | 0.134321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.748298E+10 | 0.00 | 0.00 | 0.00 | 0.307691E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.267605E+09 | 0.00 | 0.00 | 0.00 | 0.100148E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101764E+10 | 0.00 | 0.00 | 0.00 | 0.442764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.267740E+09 | 0.00 | 0.00 | 0.00 | 0.100210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.292131E+09 | 0.00 | 0.00 | 0.00 | 0.110617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.391073E+09 | 0.00 | 0.00 | 0.00 | 0.149471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.503409E+09 | 0.00 | 0.00 | 0.00 | 0.197773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.709692E+09 | 0.00 | 0.00 | 0.00 | 0.292078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.819171E+09 | 0.00 | 0.00 | 0.00 | 0.346524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.975929E+09 | 0.00 | 0.00 | 0.00 | 0.422614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101759E+10 | 0.00 | 0.00 | 0.00 | 0.442793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.874295E+09 | 0.00 | 0.00 | 0.00 | 0.369889E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.740445E+09 | 0.00 | 0.00 | 0.00 | 0.301080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.536613E+09 | 0.00 | 0.00 | 0.00 | 0.209933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.354990E+09 | 0.00 | 0.00 | 0.00 | 0.134320E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.748308E+10 | 0.00 | 0.00 | 0.00 | 0.307730E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.267740E+09 | 0.00 | 0.00 | 0.00 | 0.100210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101759E+10 | 0.00 | 0.00 | 0.00 | 0.442793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 99607596.86 | 0.00 | 0.00 | 0.00 | 0.366980E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.132852E+09 | 0.00 | 0.00 | 0.00 | 0.497194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.216946E+09 | 0.00 | 0.00 | 0.00 | 0.820689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.320603E+09 | 0.00 | 0.00 | 0.00 | 0.124811E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.505931E+09 | 0.00 | 0.00 | 0.00 | 0.205499E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.597565E+09 | 0.00 | 0.00 | 0.00 | 0.248955E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.719953E+09 | 0.00 | 0.00 | 0.00 | 0.306269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.747065E+09 | 0.00 | 0.00 | 0.00 | 0.319329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.611454E+09 | 0.00 | 0.00 | 0.00 | 0.254934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.480655E+09 | 0.00 | 0.00 | 0.00 | 0.193069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.305472E+09 | 0.00 | 0.00 | 0.00 | 0.118416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.157721E+09 | 0.00 | 0.00 | 0.00 | 0.589322E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.489583E+10 | 0.00 | 0.00 | 0.00 | 0.199870E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 99607596.86 | 0.00 | 0.00 | 0.00 | 0.366980E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.747065E+09 | 0.00 | 0.00 | 0.00 | 0.319329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 50289006.63 | 0.00 | 0.00 | 0.00 | 0.185423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 91160256.77 | 0.00 | 0.00 | 0.00 | 0.342431E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.184242E+09 | 0.00 | 0.00 | 0.00 | 0.698793E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.302269E+09 | 0.00 | 0.00 | 0.00 | 0.117795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.505000E+09 | 0.00 | 0.00 | 0.00 | 0.205293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.604220E+09 | 0.00 | 0.00 | 0.00 | 0.251889E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.719938E+09 | 0.00 | 0.00 | 0.00 | 0.306492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.735259E+09 | 0.00 | 0.00 | 0.00 | 0.314667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.579090E+09 | 0.00 | 0.00 | 0.00 | 0.241868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.427484E+09 | 0.00 | 0.00 | 0.00 | 0.172040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.245170E+09 | 0.00 | 0.00 | 0.00 | 0.952801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.102858E+09 | 0.00 | 0.00 | 0.00 | 0.385904E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.454698E+10 | 0.00 | 0.00 | 0.00 | 0.186658E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50289006.63 | 0.00 | 0.00 | 0.00 | 0.185423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.735259E+09 | 0.00 | 0.00 | 0.00 | 0.314667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 99321691.71 | 0.00 | 0.00 | 0.00 | 0.367826E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.131401E+09 | 0.00 | 0.00 | 0.00 | 0.494351E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.213555E+09 | 0.00 | 0.00 | 0.00 | 0.812235E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.321410E+09 | 0.00 | 0.00 | 0.00 | 0.125769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.506054E+09 | 0.00 | 0.00 | 0.00 | 0.206557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.594021E+09 | 0.00 | 0.00 | 0.00 | 0.248711E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.715234E+09 | 0.00 | 0.00 | 0.00 | 0.305795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.742307E+09 | 0.00 | 0.00 | 0.00 | 0.318896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.607837E+09 | 0.00 | 0.00 | 0.00 | 0.254670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.479272E+09 | 0.00 | 0.00 | 0.00 | 0.193447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.304262E+09 | 0.00 | 0.00 | 0.00 | 0.118519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.155619E+09 | 0.00 | 0.00 | 0.00 | 0.584481E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.487029E+10 | 0.00 | 0.00 | 0.00 | 0.199825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 99321691.71 | 0.00 | 0.00 | 0.00 | 0.367826E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.742307E+09 | 0.00 | 0.00 | 0.00 | 0.318896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 49538520.94 | 0.00 | 0.00 | 0.00 | 0.183722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 89650120.24 | 0.00 | 0.00 | 0.00 | 0.338633E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.181001E+09 | 0.00 | 0.00 | 0.00 | 0.690360E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.303213E+09 | 0.00 | 0.00 | 0.00 | 0.118785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.505009E+09 | 0.00 | 0.00 | 0.00 | 0.206326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.600431E+09 | 0.00 | 0.00 | 0.00 | 0.251586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.715018E+09 | 0.00 | 0.00 | 0.00 | 0.305968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.730465E+09 | 0.00 | 0.00 | 0.00 | 0.314229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.575764E+09 | 0.00 | 0.00 | 0.00 | 0.241683E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.426683E+09 | 0.00 | 0.00 | 0.00 | 0.172566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.244448E+09 | 0.00 | 0.00 | 0.00 | 0.954705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.100666E+09 | 0.00 | 0.00 | 0.00 | 0.379729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.452189E+10 | 0.00 | 0.00 | 0.00 | 0.186586E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 49538520.94 | 0.00 | 0.00 | 0.00 | 0.183722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.730465E+09 | 0.00 | 0.00 | 0.00 | 0.314229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 46722997.49 | 0.00 | 0.00 | 0.00 | 0.174012E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81226813.76 | 0.00 | 0.00 | 0.00 | 0.306940E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.157298E+09 | 0.00 | 0.00 | 0.00 | 0.599899E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.253102E+09 | 0.00 | 0.00 | 0.00 | 0.991247E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.413743E+09 | 0.00 | 0.00 | 0.00 | 0.169209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491026E+09 | 0.00 | 0.00 | 0.00 | 0.205990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585221E+09 | 0.00 | 0.00 | 0.00 | 0.250862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.595676E+09 | 0.00 | 0.00 | 0.00 | 0.256699E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473331E+09 | 0.00 | 0.00 | 0.00 | 0.198921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.356212E+09 | 0.00 | 0.00 | 0.00 | 0.144200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.211006E+09 | 0.00 | 0.00 | 0.00 | 0.824020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 93967688.64 | 0.00 | 0.00 | 0.00 | 0.354660E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.375853E+10 | 0.00 | 0.00 | 0.00 | 0.155096E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46722997.49 | 0.00 | 0.00 | 0.00 | 0.174012E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.595676E+09 | 0.00 | 0.00 | 0.00 | 0.256699E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 46953389.07 | 0.00 | 0.00 | 0.00 | 0.174906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81332185.03 | 0.00 | 0.00 | 0.00 | 0.307407E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.157265E+09 | 0.00 | 0.00 | 0.00 | 0.599923E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.253186E+09 | 0.00 | 0.00 | 0.00 | 0.991821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.413793E+09 | 0.00 | 0.00 | 0.00 | 0.169268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.490930E+09 | 0.00 | 0.00 | 0.00 | 0.205997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585086E+09 | 0.00 | 0.00 | 0.00 | 0.250860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.595545E+09 | 0.00 | 0.00 | 0.00 | 0.256700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473251E+09 | 0.00 | 0.00 | 0.00 | 0.198932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.356230E+09 | 0.00 | 0.00 | 0.00 | 0.144240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.211050E+09 | 0.00 | 0.00 | 0.00 | 0.824387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 94046317.70 | 0.00 | 0.00 | 0.00 | 0.355037E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.375867E+10 | 0.00 | 0.00 | 0.00 | 0.155135E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46953389.07 | 0.00 | 0.00 | 0.00 | 0.174906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.595545E+09 | 0.00 | 0.00 | 0.00 | 0.256700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 98714986.96 | 0.00 | 0.00 | 0.00 | 0.366174E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.124366E+09 | 0.00 | 0.00 | 0.00 | 0.468098E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190618E+09 | 0.00 | 0.00 | 0.00 | 0.724878E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.271719E+09 | 0.00 | 0.00 | 0.00 | 0.106290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.414931E+09 | 0.00 | 0.00 | 0.00 | 0.169502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.484543E+09 | 0.00 | 0.00 | 0.00 | 0.203087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585493E+09 | 0.00 | 0.00 | 0.00 | 0.250719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.607878E+09 | 0.00 | 0.00 | 0.00 | 0.261538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.506235E+09 | 0.00 | 0.00 | 0.00 | 0.212288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.409934E+09 | 0.00 | 0.00 | 0.00 | 0.165583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.271982E+09 | 0.00 | 0.00 | 0.00 | 0.105940E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.150704E+09 | 0.00 | 0.00 | 0.00 | 0.566370E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.411712E+10 | 0.00 | 0.00 | 0.00 | 0.168750E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 98714986.96 | 0.00 | 0.00 | 0.00 | 0.366174E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.607878E+09 | 0.00 | 0.00 | 0.00 | 0.261538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 98820521.97 | 0.00 | 0.00 | 0.00 | 0.366656E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.124321E+09 | 0.00 | 0.00 | 0.00 | 0.468055E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190423E+09 | 0.00 | 0.00 | 0.00 | 0.724358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.271605E+09 | 0.00 | 0.00 | 0.00 | 0.106279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.414715E+09 | 0.00 | 0.00 | 0.00 | 0.169472E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.484172E+09 | 0.00 | 0.00 | 0.00 | 0.202999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.585044E+09 | 0.00 | 0.00 | 0.00 | 0.250612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.607418E+09 | 0.00 | 0.00 | 0.00 | 0.261429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.505855E+09 | 0.00 | 0.00 | 0.00 | 0.212197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.409666E+09 | 0.00 | 0.00 | 0.00 | 0.165527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.271779E+09 | 0.00 | 0.00 | 0.00 | 0.105893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.150610E+09 | 0.00 | 0.00 | 0.00 | 0.566163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.411443E+10 | 0.00 | 0.00 | 0.00 | 0.168693E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 98820521.97 | 0.00 | 0.00 | 0.00 | 0.366656E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.607418E+09 | 0.00 | 0.00 | 0.00 | 0.261429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 5362590.37 | 53406135.25 | 0.00 | 2721422.95 | 0.00 | 0.00 | 0.370273E+09 | 0.00 | 0.35 |
| February | 9205573.55 | 0.123079E+09 | 0.00 | 1701287.17 | 0.00 | 0.00 | 0.224353E+09 | 0.00 | 0.36 |
| March | 9934336.05 | 0.255466E+09 | 0.00 | 1302628.07 | 0.00 | 0.00 | 0.148760E+09 | 0.00 | 0.36 |
| April | 278748.94 | 0.607232E+09 | 0.00 | 550904.13 | 0.00 | 0.00 | 44903257.53 | 0.00 | 0.36 |
| May | 0.00 | 0.131588E+10 | 0.00 | 46843.57 | 0.00 | 0.00 | 695094.32 | 0.00 | 0.36 |
| June | 0.00 | 0.195743E+10 | 0.00 | 3474.82 | 0.00 | 0.00 | 51251.08 | 0.00 | 0.36 |
| July | 0.00 | 0.257898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.274207E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.221012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.147910E+10 | 0.00 | 129922.99 | 0.00 | 0.00 | 1719748.33 | 0.00 | 0.36 |
| November | 0.00 | 0.676174E+09 | 0.00 | 475829.33 | 0.00 | 0.00 | 19409736.08 | 0.00 | 0.36 |
| December | 508283.05 | 0.208788E+09 | 0.00 | 2134152.65 | 0.00 | 0.00 | 0.195923E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 25289531.95 | 0.142077E+11 | 0.00 | 9066465.68 | 0.00 | 0.00 | 0.100609E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 53406135.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 9934336.05 | 0.274207E+10 | 0.00 | 2721422.95 | 0.00 | 0.00 | 0.370273E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 55181126.08 | 42548585.19 | 0.00 | 1816287.11 | 0.00 | 0.00 | 0.337776E+09 | 0.00 | 0.35 |
| February | 32942873.86 | 0.108277E+09 | 0.00 | 1294892.40 | 0.00 | 0.00 | 0.216045E+09 | 0.00 | 0.36 |
| March | 20561982.56 | 0.242159E+09 | 0.00 | 1087261.16 | 0.00 | 0.00 | 0.143676E+09 | 0.00 | 0.36 |
| April | 894218.43 | 0.596924E+09 | 0.00 | 532761.02 | 0.00 | 0.00 | 45449536.84 | 0.00 | 0.36 |
| May | 0.00 | 0.131769E+10 | 0.00 | 46877.91 | 0.00 | 0.00 | 686404.29 | 0.00 | 0.36 |
| June | 0.00 | 0.196454E+10 | 0.00 | 2915.79 | 0.00 | 0.00 | 47792.11 | 0.00 | 0.36 |
| July | 0.00 | 0.258287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.273596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.218763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.144686E+10 | 0.00 | 118493.98 | 0.00 | 0.00 | 1786554.72 | 0.00 | 0.36 |
| November | 0.00 | 0.641692E+09 | 0.00 | 445236.93 | 0.00 | 0.00 | 21875526.61 | 0.00 | 0.36 |
| December | 3978661.11 | 0.184104E+09 | 0.00 | 1717837.10 | 0.00 | 0.00 | 0.207617E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.113559E+09 | 0.140513E+11 | 0.00 | 7062563.40 | 0.00 | 0.00 | 0.974960E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 42548585.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 55181126.08 | 0.273596E+10 | 0.00 | 1816287.11 | 0.00 | 0.00 | 0.337776E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.805171E+09 | 46249643.83 | 0.00 | 1494696.59 | 2458365.93 | 0.00 | 78138418.24 | 0.00 | 0.53 |
| February | 0.602097E+09 | 85354880.80 | 0.00 | 1143873.19 | 10344567.20 | 0.00 | 40750299.88 | 0.00 | 0.53 |
| March | 0.516252E+09 | 0.174220E+09 | 0.00 | 952365.15 | 28676743.72 | 0.00 | 33246625.94 | 0.00 | 0.53 |
| April | 0.354754E+09 | 0.317357E+09 | 0.00 | 595869.21 | 90881032.31 | 0.00 | 17438672.80 | 0.00 | 0.53 |
| May | 0.133645E+09 | 0.745372E+09 | 0.00 | 449636.76 | 0.219559E+09 | 0.00 | 15812544.44 | 0.00 | 0.54 |
| June | 53823411.34 | 0.113466E+10 | 0.00 | 180331.89 | 0.412377E+09 | 0.00 | 2805762.76 | 0.00 | 0.54 |
| July | 10344376.93 | 0.175935E+10 | 0.00 | 66013.02 | 0.503161E+09 | 0.00 | 9208475.54 | 0.00 | 0.54 |
| August | 1023679.27 | 0.211414E+10 | 0.00 | 28495.04 | 0.386181E+09 | 0.00 | 404457.02 | 0.00 | 0.54 |
| September | 26459696.64 | 0.140489E+10 | 0.00 | 156614.21 | 0.323372E+09 | 0.00 | 4071416.64 | 0.00 | 0.54 |
| October | 91486496.96 | 0.862510E+09 | 0.00 | 316046.01 | 0.177546E+09 | 0.00 | 25134667.85 | 0.00 | 0.53 |
| November | 0.334270E+09 | 0.408423E+09 | 0.00 | 678948.57 | 54321367.48 | 0.00 | 40915357.94 | 0.00 | 0.53 |
| December | 0.678957E+09 | 0.121189E+09 | 0.00 | 1226296.17 | 15907516.44 | 0.00 | 37239224.49 | 0.00 | 0.53 |
| Annual Sum or Average | 0.360828E+10 | 0.917372E+10 | 0.00 | 7289185.79 | 0.222479E+10 | 0.00 | 0.305166E+09 | 0.00 | 0.53 |
| Minimum of Months | 1023679.27 | 46249643.83 | 0.00 | 28495.04 | 2458365.93 | 0.00 | 404457.02 | 0.00 | 0.53 |
| Maximum of Months | 0.805171E+09 | 0.211414E+10 | 0.00 | 1494696.59 | 0.503161E+09 | 0.00 | 78138418.24 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 51429492.93 | 42899835.78 | 0.00 | 1875358.86 | 0.00 | 0.00 | 0.342295E+09 | 0.00 | 0.35 |
| February | 31310661.09 | 0.108060E+09 | 0.00 | 1330981.22 | 0.00 | 0.00 | 0.218802E+09 | 0.00 | 0.36 |
| March | 20291400.29 | 0.241103E+09 | 0.00 | 1076063.90 | 0.00 | 0.00 | 0.145503E+09 | 0.00 | 0.36 |
| April | 1027668.44 | 0.595933E+09 | 0.00 | 551106.47 | 0.00 | 0.00 | 45705359.97 | 0.00 | 0.36 |
| May | 0.00 | 0.131586E+10 | 0.00 | 50557.62 | 0.00 | 0.00 | 711204.36 | 0.00 | 0.36 |
| June | 0.00 | 0.196211E+10 | 0.00 | 3496.16 | 0.00 | 0.00 | 51127.18 | 0.00 | 0.36 |
| July | 0.00 | 0.258062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.273378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.218505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.144688E+10 | 0.00 | 122686.26 | 0.00 | 0.00 | 1794576.06 | 0.00 | 0.36 |
| November | 0.00 | 0.641138E+09 | 0.00 | 456865.02 | 0.00 | 0.00 | 22107048.23 | 0.00 | 0.36 |
| December | 2183884.17 | 0.183200E+09 | 0.00 | 1752866.85 | 0.00 | 0.00 | 0.210669E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.106243E+09 | 0.140366E+11 | 0.00 | 7219982.36 | 0.00 | 0.00 | 0.987639E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 42899835.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 51429492.93 | 0.273378E+10 | 0.00 | 1875358.86 | 0.00 | 0.00 | 0.342295E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 6661524.43 | 42072042.35 | 0.00 | 2115812.11 | 0.00 | 0.00 | 0.386707E+09 | 0.00 | 0.35 |
| February | 6408873.15 | 0.109104E+09 | 0.00 | 1487325.26 | 0.00 | 0.00 | 0.238742E+09 | 0.00 | 0.36 |
| March | 7541042.48 | 0.240319E+09 | 0.00 | 1205509.81 | 0.00 | 0.00 | 0.155968E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.593679E+09 | 0.00 | 570800.89 | 0.00 | 0.00 | 45485047.43 | 0.00 | 0.36 |
| May | 0.00 | 0.129869E+10 | 0.00 | 51754.55 | 0.00 | 0.00 | 819385.94 | 0.00 | 0.36 |
| June | 0.00 | 0.193826E+10 | 0.00 | 3025.37 | 0.00 | 0.00 | 74126.25 | 0.00 | 0.36 |
| July | 0.00 | 0.254638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.269225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.214791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.141599E+10 | 0.00 | 111036.54 | 0.00 | 0.00 | 2172492.13 | 0.00 | 0.36 |
| November | 0.00 | 0.624956E+09 | 0.00 | 444889.93 | 0.00 | 0.00 | 22990591.91 | 0.00 | 0.36 |
| December | 233412.69 | 0.179941E+09 | 0.00 | 1782104.67 | 0.00 | 0.00 | 0.211443E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 20844852.75 | 0.138296E+11 | 0.00 | 7772259.12 | 0.00 | 0.00 | 0.106440E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 42072042.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 7541042.48 | 0.269225E+10 | 0.00 | 2115812.11 | 0.00 | 0.00 | 0.386707E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 6672588.72 | 42114208.71 | 0.00 | 2116315.70 | 0.00 | 0.00 | 0.386681E+09 | 0.00 | 0.35 |
| February | 6334100.11 | 0.109135E+09 | 0.00 | 1487476.27 | 0.00 | 0.00 | 0.238825E+09 | 0.00 | 0.36 |
| March | 7715642.72 | 0.240323E+09 | 0.00 | 1203790.38 | 0.00 | 0.00 | 0.155851E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.593756E+09 | 0.00 | 570852.72 | 0.00 | 0.00 | 45488605.01 | 0.00 | 0.36 |
| May | 0.00 | 0.129878E+10 | 0.00 | 51753.60 | 0.00 | 0.00 | 819228.76 | 0.00 | 0.36 |
| June | 0.00 | 0.193829E+10 | 0.00 | 3023.45 | 0.00 | 0.00 | 74189.64 | 0.00 | 0.36 |
| July | 0.00 | 0.254644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.269233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.214795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.141610E+10 | 0.00 | 111094.08 | 0.00 | 0.00 | 2171628.86 | 0.00 | 0.36 |
| November | 0.00 | 0.625034E+09 | 0.00 | 444967.34 | 0.00 | 0.00 | 22994828.78 | 0.00 | 0.36 |
| December | 208170.37 | 0.179963E+09 | 0.00 | 1781917.98 | 0.00 | 0.00 | 0.211498E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 20930501.92 | 0.138302E+11 | 0.00 | 7771191.52 | 0.00 | 0.00 | 0.106440E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 42114208.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 7715642.72 | 0.269233E+10 | 0.00 | 2116315.70 | 0.00 | 0.00 | 0.386681E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 54305211.75 | 0.00 | 2987355.93 | 0.00 | 0.00 | 0.372627E+09 | 0.00 | 0.35 |
| February | 620780.09 | 0.126418E+09 | 0.00 | 1903356.44 | 0.00 | 0.00 | 0.226393E+09 | 0.00 | 0.36 |
| March | 1909939.74 | 0.256744E+09 | 0.00 | 1447991.52 | 0.00 | 0.00 | 0.154336E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.607958E+09 | 0.00 | 585451.18 | 0.00 | 0.00 | 43787287.60 | 0.00 | 0.36 |
| May | 0.00 | 0.130001E+10 | 0.00 | 51601.82 | 0.00 | 0.00 | 794520.51 | 0.00 | 0.36 |
| June | 0.00 | 0.193315E+10 | 0.00 | 2963.03 | 0.00 | 0.00 | 76863.04 | 0.00 | 0.36 |
| July | 0.00 | 0.254545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.270402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.218010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.145936E+10 | 0.00 | 125026.84 | 0.00 | 0.00 | 1996056.96 | 0.00 | 0.36 |
| November | 0.00 | 0.668900E+09 | 0.00 | 469098.83 | 0.00 | 0.00 | 19775189.65 | 0.00 | 0.36 |
| December | 0.00 | 0.209193E+09 | 0.00 | 2197590.74 | 0.00 | 0.00 | 0.194021E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 2530719.83 | 0.140456E+11 | 0.00 | 9770436.33 | 0.00 | 0.00 | 0.101381E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 54305211.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 1909939.74 | 0.270402E+10 | 0.00 | 2987355.93 | 0.00 | 0.00 | 0.372627E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 56814581.42 | 0.00 | 3247477.01 | 0.00 | 0.00 | 0.365853E+09 | 0.00 | 0.35 |
| February | 89330.29 | 0.131367E+09 | 0.00 | 2079248.66 | 0.00 | 0.00 | 0.219413E+09 | 0.00 | 0.36 |
| March | 1112914.93 | 0.263678E+09 | 0.00 | 1617222.01 | 0.00 | 0.00 | 0.149579E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.624918E+09 | 0.00 | 650941.81 | 0.00 | 0.00 | 40182959.01 | 0.00 | 0.36 |
| May | 0.00 | 0.132404E+10 | 0.00 | 50790.37 | 0.00 | 0.00 | 563609.52 | 0.00 | 0.36 |
| June | 0.00 | 0.196395E+10 | 0.00 | 3327.89 | 0.00 | 0.00 | 58935.32 | 0.00 | 0.36 |
| July | 0.00 | 0.257716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.273430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.221135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.148644E+10 | 0.00 | 129376.84 | 0.00 | 0.00 | 1734534.94 | 0.00 | 0.36 |
| November | 0.00 | 0.687496E+09 | 0.00 | 499584.49 | 0.00 | 0.00 | 17852491.29 | 0.00 | 0.36 |
| December | 0.00 | 0.218049E+09 | 0.00 | 2356287.12 | 0.00 | 0.00 | 0.186290E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 1202245.22 | 0.142796E+11 | 0.00 | 10634256.20 | 0.00 | 0.00 | 0.981528E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 56814581.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 1112914.93 | 0.273430E+10 | 0.00 | 3247477.01 | 0.00 | 0.00 | 0.365853E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.124762E+09 | 96910227.42 | 0.00 | 4380906.87 | 0.00 | 0.00 | 0.642451E+09 | 0.00 | 0.35 |
| February | 59818997.42 | 0.233521E+09 | 0.00 | 3179219.17 | 0.00 | 0.00 | 0.415333E+09 | 0.00 | 0.36 |
| March | 16559207.94 | 0.511051E+09 | 0.00 | 2864888.44 | 1784.60 | 0.00 | 0.292302E+09 | 0.00 | 0.36 |
| April | 1843429.57 | 0.122496E+10 | 0.00 | 1176945.38 | 0.00 | 0.00 | 82915120.35 | 0.00 | 0.36 |
| May | 0.00 | 0.261806E+10 | 0.00 | 85440.51 | 0.00 | 0.00 | 1366071.42 | 0.00 | 0.36 |
| June | 0.00 | 0.385454E+10 | 0.00 | 6861.16 | 0.00 | 0.00 | 109336.42 | 0.00 | 0.36 |
| July | 0.00 | 0.505751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.533091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.425254E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.280310E+10 | 0.00 | 222566.24 | 0.00 | 0.00 | 4779048.84 | 0.00 | 0.36 |
| November | 1927262.97 | 0.124221E+10 | 0.00 | 889432.60 | 0.00 | 0.00 | 51964132.46 | 0.00 | 0.36 |
| December | 38909557.01 | 0.377706E+09 | 0.00 | 3297366.90 | 0.00 | 0.00 | 0.399359E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.243821E+09 | 0.276030E+11 | 0.00 | 16103627.27 | 1784.60 | 0.00 | 0.189058E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 96910227.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.124762E+09 | 0.533091E+10 | 0.00 | 4380906.87 | 1784.60 | 0.00 | 0.642451E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.329245E+09 | 74263256.93 | 0.00 | 2626472.37 | 0.00 | 0.00 | 0.463001E+09 | 0.00 | 0.35 |
| February | 0.124774E+09 | 0.204658E+09 | 0.00 | 2360898.90 | 0.00 | 0.00 | 0.376040E+09 | 0.00 | 0.36 |
| March | 30802055.71 | 0.485572E+09 | 0.00 | 2463862.80 | 40207.32 | 0.00 | 0.287622E+09 | 0.00 | 0.36 |
| April | 1990765.66 | 0.120403E+10 | 0.00 | 1147637.43 | 0.00 | 0.00 | 84719711.96 | 0.00 | 0.36 |
| May | 0.00 | 0.261721E+10 | 0.00 | 88366.16 | 0.00 | 0.00 | 1384315.25 | 0.00 | 0.36 |
| June | 0.00 | 0.386294E+10 | 0.00 | 6952.94 | 0.00 | 0.00 | 106044.09 | 0.00 | 0.36 |
| July | 0.00 | 0.505921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.531164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.419697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.272343E+10 | 0.00 | 192246.71 | 0.00 | 0.00 | 5125284.89 | 0.00 | 0.36 |
| November | 2331632.37 | 0.116031E+10 | 0.00 | 806420.43 | 0.00 | 0.00 | 60092542.42 | 0.00 | 0.36 |
| December | 92302954.42 | 0.322931E+09 | 0.00 | 2298462.48 | 0.00 | 0.00 | 0.379402E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.581446E+09 | 0.272232E+11 | 0.00 | 11991320.21 | 40207.32 | 0.00 | 0.165749E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 74263256.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.329245E+09 | 0.531164E+10 | 0.00 | 2626472.37 | 40207.32 | 0.00 | 0.463001E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.113064E+09 | 97911894.81 | 0.00 | 4523143.43 | 0.00 | 0.00 | 0.654675E+09 | 0.00 | 0.35 |
| February | 50968579.57 | 0.233746E+09 | 0.00 | 3258472.57 | 0.00 | 0.00 | 0.425492E+09 | 0.00 | 0.36 |
| March | 15314849.33 | 0.510539E+09 | 0.00 | 2871460.84 | 0.00 | 0.00 | 0.295333E+09 | 0.00 | 0.36 |
| April | 2228642.61 | 0.122514E+10 | 0.00 | 1213638.60 | 0.00 | 0.00 | 82830484.68 | 0.00 | 0.36 |
| May | 0.00 | 0.261828E+10 | 0.00 | 88822.07 | 0.00 | 0.00 | 1386897.16 | 0.00 | 0.36 |
| June | 0.00 | 0.385429E+10 | 0.00 | 6727.34 | 0.00 | 0.00 | 115302.52 | 0.00 | 0.36 |
| July | 0.00 | 0.505795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.533157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.425222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.280870E+10 | 0.00 | 236697.47 | 0.00 | 0.00 | 4686217.89 | 0.00 | 0.36 |
| November | 1420384.26 | 0.124538E+10 | 0.00 | 927763.57 | 0.00 | 0.00 | 52649986.41 | 0.00 | 0.36 |
| December | 35873905.84 | 0.377696E+09 | 0.00 | 3368028.87 | 0.00 | 0.00 | 0.403918E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.218871E+09 | 0.276134E+11 | 0.00 | 16494754.76 | 0.00 | 0.00 | 0.192109E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 97911894.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.113064E+09 | 0.533157E+10 | 0.00 | 4523143.43 | 0.00 | 0.00 | 0.654675E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.313360E+09 | 75625708.13 | 0.00 | 2732130.53 | 0.00 | 0.00 | 0.481001E+09 | 0.00 | 0.35 |
| February | 0.116670E+09 | 0.205174E+09 | 0.00 | 2421468.88 | 0.00 | 0.00 | 0.386090E+09 | 0.00 | 0.36 |
| March | 30123208.59 | 0.485054E+09 | 0.00 | 2459952.73 | 0.00 | 0.00 | 0.290369E+09 | 0.00 | 0.36 |
| April | 1997224.68 | 0.120429E+10 | 0.00 | 1180333.07 | 0.00 | 0.00 | 85099634.93 | 0.00 | 0.36 |
| May | 0.00 | 0.261740E+10 | 0.00 | 91286.78 | 0.00 | 0.00 | 1406060.13 | 0.00 | 0.36 |
| June | 0.00 | 0.386269E+10 | 0.00 | 6822.95 | 0.00 | 0.00 | 111932.40 | 0.00 | 0.36 |
| July | 0.00 | 0.505962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.531236E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.419674E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.273025E+10 | 0.00 | 203759.02 | 0.00 | 0.00 | 5044147.71 | 0.00 | 0.36 |
| November | 2059361.66 | 0.116443E+10 | 0.00 | 843931.20 | 0.00 | 0.00 | 60701872.26 | 0.00 | 0.36 |
| December | 85339643.89 | 0.322700E+09 | 0.00 | 2350095.25 | 0.00 | 0.00 | 0.388635E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.549549E+09 | 0.272363E+11 | 0.00 | 12289780.41 | 0.00 | 0.00 | 0.169846E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 75625708.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.313360E+09 | 0.531236E+10 | 0.00 | 2732130.53 | 0.00 | 0.00 | 0.481001E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 63475275.31 | 76953423.41 | 0.00 | 3704271.20 | 0.00 | 0.00 | 0.730123E+09 | 0.00 | 0.35 |
| February | 20170250.02 | 0.210727E+09 | 0.00 | 2956145.10 | 0.00 | 0.00 | 0.469419E+09 | 0.00 | 0.36 |
| March | 6643101.54 | 0.483698E+09 | 0.00 | 2681565.06 | 0.00 | 0.00 | 0.309885E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.119763E+10 | 0.00 | 1179455.63 | 0.00 | 0.00 | 85751842.00 | 0.00 | 0.36 |
| May | 0.00 | 0.258332E+10 | 0.00 | 96730.28 | 0.00 | 0.00 | 1626210.18 | 0.00 | 0.36 |
| June | 0.00 | 0.382146E+10 | 0.00 | 5815.76 | 0.00 | 0.00 | 159681.30 | 0.00 | 0.36 |
| July | 0.00 | 0.500239E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.524933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.415044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.270047E+10 | 0.00 | 192224.12 | 0.00 | 0.00 | 5512530.50 | 0.00 | 0.36 |
| November | 67675.30 | 0.116096E+10 | 0.00 | 837622.73 | 0.00 | 0.00 | 58212352.54 | 0.00 | 0.36 |
| December | 21548669.12 | 0.328954E+09 | 0.00 | 2905054.98 | 0.00 | 0.00 | 0.432441E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.111905E+09 | 0.269663E+11 | 0.00 | 14558884.87 | 0.00 | 0.00 | 0.209313E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 76953423.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 63475275.31 | 0.524933E+10 | 0.00 | 3704271.20 | 0.00 | 0.00 | 0.730123E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 64033874.62 | 77060490.19 | 0.00 | 3707868.31 | 0.00 | 0.00 | 0.729517E+09 | 0.00 | 0.35 |
| February | 20062578.90 | 0.210797E+09 | 0.00 | 2956831.88 | 0.00 | 0.00 | 0.469552E+09 | 0.00 | 0.36 |
| March | 6643380.34 | 0.483723E+09 | 0.00 | 2678569.22 | 0.00 | 0.00 | 0.309986E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.119775E+10 | 0.00 | 1179308.61 | 0.00 | 0.00 | 85771288.23 | 0.00 | 0.36 |
| May | 0.00 | 0.258345E+10 | 0.00 | 96701.46 | 0.00 | 0.00 | 1627055.42 | 0.00 | 0.36 |
| June | 0.00 | 0.382151E+10 | 0.00 | 5810.88 | 0.00 | 0.00 | 159868.77 | 0.00 | 0.36 |
| July | 0.00 | 0.500249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.524945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.415049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.270070E+10 | 0.00 | 192338.48 | 0.00 | 0.00 | 5511991.67 | 0.00 | 0.36 |
| November | 67675.78 | 0.116114E+10 | 0.00 | 837665.28 | 0.00 | 0.00 | 58236308.40 | 0.00 | 0.36 |
| December | 21487681.27 | 0.329029E+09 | 0.00 | 2904829.48 | 0.00 | 0.00 | 0.432587E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.112295E+09 | 0.269676E+11 | 0.00 | 14559923.60 | 0.00 | 0.00 | 0.209295E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 77060490.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 64033874.62 | 0.524945E+10 | 0.00 | 3707868.31 | 0.00 | 0.00 | 0.729517E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 4914703.90 | 0.100929E+09 | 0.00 | 5538197.58 | 0.00 | 0.00 | 0.751839E+09 | 0.00 | 0.35 |
| February | 2638238.25 | 0.242226E+09 | 0.00 | 3761576.63 | 0.00 | 0.00 | 0.456912E+09 | 0.00 | 0.36 |
| March | 3456781.73 | 0.512053E+09 | 0.00 | 3113213.03 | 0.00 | 0.00 | 0.302707E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.122000E+10 | 0.00 | 1218268.50 | 0.00 | 0.00 | 83971440.92 | 0.00 | 0.36 |
| May | 0.00 | 0.258011E+10 | 0.00 | 96952.07 | 0.00 | 0.00 | 1634726.76 | 0.00 | 0.36 |
| June | 0.00 | 0.380614E+10 | 0.00 | 5719.30 | 0.00 | 0.00 | 167539.24 | 0.00 | 0.36 |
| July | 0.00 | 0.499528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.526901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.421541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.279186E+10 | 0.00 | 221202.86 | 0.00 | 0.00 | 5144759.19 | 0.00 | 0.36 |
| November | 0.00 | 0.125244E+10 | 0.00 | 900782.72 | 0.00 | 0.00 | 50098134.90 | 0.00 | 0.36 |
| December | 3114332.03 | 0.388817E+09 | 0.00 | 3855027.53 | 0.00 | 0.00 | 0.415733E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 14124055.91 | 0.273743E+11 | 0.00 | 18710940.24 | 0.00 | 0.00 | 0.206821E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.100929E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 4914703.90 | 0.526901E+10 | 0.00 | 5538197.58 | 0.00 | 0.00 | 0.751839E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 4914903.31 | 0.101002E+09 | 0.00 | 5540333.07 | 0.00 | 0.00 | 0.751832E+09 | 0.00 | 0.35 |
| February | 2594028.81 | 0.242274E+09 | 0.00 | 3761546.65 | 0.00 | 0.00 | 0.456989E+09 | 0.00 | 0.36 |
| March | 3456719.65 | 0.512074E+09 | 0.00 | 3110141.77 | 0.00 | 0.00 | 0.302793E+09 | 0.00 | 0.36 |
| April | 0.00 | 0.122011E+10 | 0.00 | 1217896.48 | 0.00 | 0.00 | 83988210.83 | 0.00 | 0.36 |
| May | 0.00 | 0.258024E+10 | 0.00 | 96922.94 | 0.00 | 0.00 | 1635541.64 | 0.00 | 0.36 |
| June | 0.00 | 0.380618E+10 | 0.00 | 5714.44 | 0.00 | 0.00 | 167732.25 | 0.00 | 0.36 |
| July | 0.00 | 0.499538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.526913E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.421545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.279204E+10 | 0.00 | 221357.65 | 0.00 | 0.00 | 5143668.36 | 0.00 | 0.36 |
| November | 0.00 | 0.125258E+10 | 0.00 | 900997.54 | 0.00 | 0.00 | 50113031.72 | 0.00 | 0.36 |
| December | 3114441.71 | 0.388873E+09 | 0.00 | 3854466.03 | 0.00 | 0.00 | 0.415793E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 14080093.48 | 0.273753E+11 | 0.00 | 18709376.58 | 0.00 | 0.00 | 0.206846E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.101002E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 4914903.31 | 0.526913E+10 | 0.00 | 5540333.07 | 0.00 | 0.00 | 0.751832E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.260444E+09 | 43182010.88 | 0.00 | 1193701.79 | 207714.58 | 0.00 | 0.101183E+09 | 0.00 | 0.35 |
| February | 0.165576E+09 | 0.105250E+09 | 0.00 | 910920.58 | 37096.71 | 0.00 | 75664878.14 | 0.00 | 0.36 |
| March | 86862838.61 | 0.245555E+09 | 0.00 | 799452.18 | 105079.75 | 0.00 | 77965424.13 | 0.00 | 0.36 |
| April | 16798398.75 | 0.592955E+09 | 0.00 | 338720.74 | 241924.71 | 0.00 | 39521384.19 | 0.00 | 0.36 |
| May | 0.00 | 0.130056E+10 | 0.00 | 44128.83 | 0.00 | 0.00 | 1267281.47 | 0.00 | 0.36 |
| June | 0.00 | 0.192558E+10 | 0.00 | 3106.78 | 0.00 | 0.00 | 64039.57 | 0.00 | 0.36 |
| July | 0.00 | 0.254358E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.267898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.211563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.136856E+10 | 0.00 | 82515.89 | 0.00 | 0.00 | 3486387.15 | 0.00 | 0.36 |
| November | 16857612.51 | 0.587977E+09 | 0.00 | 245407.22 | 0.00 | 0.00 | 26920205.45 | 0.00 | 0.36 |
| December | 0.160241E+09 | 0.174380E+09 | 0.00 | 825816.10 | 0.00 | 0.00 | 74471210.40 | 0.00 | 0.36 |
| Annual Sum or Average | 0.706779E+09 | 0.136822E+11 | 0.00 | 4443770.12 | 591815.75 | 0.00 | 0.400544E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 43182010.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.260444E+09 | 0.267898E+10 | 0.00 | 1193701.79 | 241924.71 | 0.00 | 0.101183E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.275848E+09 | 32220438.98 | 0.00 | 617399.33 | 817449.76 | 60534.04 | 82800395.10 | 0.00 | 0.35 |
| February | 0.178665E+09 | 92376440.84 | 0.00 | 653529.49 | 338802.74 | 0.00 | 65863464.80 | 0.00 | 0.36 |
| March | 92395146.68 | 0.234010E+09 | 0.00 | 670334.97 | 219045.36 | 0.00 | 73871215.43 | 0.00 | 0.36 |
| April | 17732548.30 | 0.585107E+09 | 0.00 | 331807.27 | 228628.10 | 0.00 | 39342640.19 | 0.00 | 0.36 |
| May | 0.00 | 0.130222E+10 | 0.00 | 44754.01 | 0.00 | 0.00 | 1263604.53 | 0.00 | 0.36 |
| June | 0.00 | 0.193078E+10 | 0.00 | 3121.09 | 0.00 | 0.00 | 62671.28 | 0.00 | 0.36 |
| July | 0.00 | 0.254584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.267277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.209453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.133653E+10 | 0.00 | 70869.51 | 0.00 | 0.00 | 3631613.94 | 0.00 | 0.36 |
| November | 20024138.95 | 0.551939E+09 | 0.00 | 203825.03 | 5294.64 | 0.00 | 26985581.63 | 0.00 | 0.36 |
| December | 0.174761E+09 | 0.146472E+09 | 0.00 | 535503.53 | 765146.00 | 0.00 | 63918708.75 | 0.00 | 0.36 |
| Annual Sum or Average | 0.759426E+09 | 0.135248E+11 | 0.00 | 3131144.23 | 2374366.60 | 60534.04 | 0.357740E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 32220438.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.275848E+09 | 0.267277E+10 | 0.00 | 670334.97 | 817449.76 | 60534.04 | 82800395.10 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.261857E+09 | 43704719.82 | 0.00 | 1198233.39 | 149826.65 | 0.00 | 0.102590E+09 | 0.00 | 0.35 |
| February | 0.168701E+09 | 0.105166E+09 | 0.00 | 918112.35 | 0.00 | 0.00 | 74403928.03 | 0.00 | 0.36 |
| March | 87745704.02 | 0.245048E+09 | 0.00 | 808191.88 | 39104.91 | 0.00 | 78515702.47 | 0.00 | 0.36 |
| April | 16729334.26 | 0.592379E+09 | 0.00 | 361483.74 | 209188.85 | 0.00 | 39974565.16 | 0.00 | 0.36 |
| May | 0.00 | 0.129970E+10 | 0.00 | 47001.90 | 0.00 | 0.00 | 1293051.05 | 0.00 | 0.36 |
| June | 0.00 | 0.192485E+10 | 0.00 | 3043.13 | 0.00 | 0.00 | 67929.29 | 0.00 | 0.36 |
| July | 0.00 | 0.254280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.267828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.211485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.137136E+10 | 0.00 | 91204.59 | 0.00 | 0.00 | 3438145.12 | 0.00 | 0.36 |
| November | 16617122.97 | 0.589795E+09 | 0.00 | 273755.45 | 0.00 | 0.00 | 27500868.03 | 0.00 | 0.36 |
| December | 0.161103E+09 | 0.174006E+09 | 0.00 | 840812.10 | 0.00 | 0.00 | 75345054.30 | 0.00 | 0.36 |
| Annual Sum or Average | 0.712752E+09 | 0.136819E+11 | 0.00 | 4541838.53 | 398120.41 | 0.00 | 0.403129E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 43704719.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.261857E+09 | 0.267828E+10 | 0.00 | 1198233.39 | 209188.85 | 0.00 | 0.102590E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.280885E+09 | 32750866.27 | 0.00 | 606719.01 | 483150.75 | 0.00 | 81538007.49 | 0.00 | 0.35 |
| February | 0.179954E+09 | 92531159.95 | 0.00 | 635953.04 | 27957.19 | 0.00 | 66872998.38 | 0.00 | 0.36 |
| March | 93737726.99 | 0.233677E+09 | 0.00 | 669920.19 | 89189.07 | 0.00 | 74165262.52 | 0.00 | 0.36 |
| April | 17845417.98 | 0.584624E+09 | 0.00 | 360786.54 | 199169.30 | 0.00 | 39653940.03 | 0.00 | 0.36 |
| May | 0.00 | 0.130132E+10 | 0.00 | 47056.10 | 0.00 | 0.00 | 1288681.48 | 0.00 | 0.36 |
| June | 0.00 | 0.193001E+10 | 0.00 | 3054.40 | 0.00 | 0.00 | 66519.51 | 0.00 | 0.36 |
| July | 0.00 | 0.254504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.267212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.209390E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.134026E+10 | 0.00 | 78740.45 | 0.00 | 0.00 | 3592674.69 | 0.00 | 0.36 |
| November | 20248472.07 | 0.554702E+09 | 0.00 | 228232.28 | 0.00 | 0.00 | 27282103.34 | 0.00 | 0.36 |
| December | 0.177470E+09 | 0.146328E+09 | 0.00 | 520339.09 | 180535.71 | 0.00 | 63519827.02 | 0.00 | 0.36 |
| Annual Sum or Average | 0.770141E+09 | 0.135273E+11 | 0.00 | 3150801.10 | 980002.03 | 0.00 | 0.357980E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 32750866.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.280885E+09 | 0.267212E+10 | 0.00 | 669920.19 | 483150.75 | 0.00 | 81538007.49 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.276904E+09 | 32744791.59 | 0.00 | 681420.87 | 486243.16 | 0.00 | 0.104420E+09 | 0.00 | 0.35 |
| February | 0.161958E+09 | 95218096.88 | 0.00 | 684772.37 | 60549.53 | 0.00 | 94240639.19 | 0.00 | 0.36 |
| March | 77296945.86 | 0.234570E+09 | 0.00 | 734119.21 | 115644.47 | 0.00 | 93647170.53 | 0.00 | 0.36 |
| April | 9086662.34 | 0.588106E+09 | 0.00 | 378122.47 | 62821.13 | 0.00 | 46200901.78 | 0.00 | 0.36 |
| May | 0.00 | 0.129660E+10 | 0.00 | 47167.06 | 0.00 | 0.00 | 1294222.00 | 0.00 | 0.36 |
| June | 0.00 | 0.192810E+10 | 0.00 | 2728.14 | 0.00 | 0.00 | 82004.87 | 0.00 | 0.36 |
| July | 0.00 | 0.253837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.266395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.209111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.133894E+10 | 0.00 | 77782.94 | 0.00 | 0.00 | 3689070.33 | 0.00 | 0.36 |
| November | 12378634.99 | 0.557648E+09 | 0.00 | 251515.94 | 0.00 | 0.00 | 31168912.13 | 0.00 | 0.36 |
| December | 0.150693E+09 | 0.149198E+09 | 0.00 | 613415.52 | 316371.38 | 0.00 | 96880864.68 | 0.00 | 0.36 |
| Annual Sum or Average | 0.688317E+09 | 0.135146E+11 | 0.00 | 3471044.52 | 1041629.67 | 0.00 | 0.471624E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 32744791.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.276904E+09 | 0.266395E+10 | 0.00 | 734119.21 | 486243.16 | 0.00 | 0.104420E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.276874E+09 | 32850444.44 | 0.00 | 684344.53 | 468473.14 | 0.00 | 0.104468E+09 | 0.00 | 0.35 |
| February | 0.162301E+09 | 95292406.87 | 0.00 | 684896.59 | 56649.32 | 0.00 | 93934018.81 | 0.00 | 0.36 |
| March | 77795319.65 | 0.234627E+09 | 0.00 | 732822.81 | 114635.27 | 0.00 | 93203065.05 | 0.00 | 0.36 |
| April | 9131334.51 | 0.588167E+09 | 0.00 | 378298.45 | 62908.59 | 0.00 | 46189559.45 | 0.00 | 0.36 |
| May | 0.00 | 0.129667E+10 | 0.00 | 47154.89 | 0.00 | 0.00 | 1295622.33 | 0.00 | 0.36 |
| June | 0.00 | 0.192815E+10 | 0.00 | 2724.56 | 0.00 | 0.00 | 82134.61 | 0.00 | 0.36 |
| July | 0.00 | 0.253846E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.266405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.209116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.133912E+10 | 0.00 | 77941.20 | 0.00 | 0.00 | 3688973.62 | 0.00 | 0.36 |
| November | 12479004.81 | 0.557842E+09 | 0.00 | 251779.11 | 0.00 | 0.00 | 31097647.81 | 0.00 | 0.36 |
| December | 0.151114E+09 | 0.149307E+09 | 0.00 | 612834.39 | 314125.69 | 0.00 | 96506439.99 | 0.00 | 0.36 |
| Annual Sum or Average | 0.689694E+09 | 0.135157E+11 | 0.00 | 3472796.52 | 1016792.01 | 0.00 | 0.470466E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 32850444.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.276874E+09 | 0.266405E+10 | 0.00 | 732822.81 | 468473.14 | 0.00 | 0.104468E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.244424E+09 | 45427442.99 | 0.00 | 1323102.28 | 71037.26 | 0.00 | 0.135847E+09 | 0.00 | 0.35 |
| February | 0.142338E+09 | 0.110714E+09 | 0.00 | 983595.04 | 0.00 | 0.00 | 0.106968E+09 | 0.00 | 0.36 |
| March | 69372185.67 | 0.249074E+09 | 0.00 | 882484.59 | 78403.09 | 0.00 | 98669712.25 | 0.00 | 0.36 |
| April | 9333196.15 | 0.599041E+09 | 0.00 | 376807.40 | 67297.73 | 0.00 | 44989233.31 | 0.00 | 0.36 |
| May | 0.00 | 0.129667E+10 | 0.00 | 45966.00 | 0.00 | 0.00 | 1278592.21 | 0.00 | 0.36 |
| June | 0.00 | 0.192369E+10 | 0.00 | 2714.85 | 0.00 | 0.00 | 82428.22 | 0.00 | 0.36 |
| July | 0.00 | 0.253775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.267406E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.211930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.137909E+10 | 0.00 | 86758.87 | 0.00 | 0.00 | 3497220.54 | 0.00 | 0.36 |
| November | 9705955.75 | 0.601361E+09 | 0.00 | 302268.07 | 0.00 | 0.00 | 29916518.57 | 0.00 | 0.36 |
| December | 0.131580E+09 | 0.181763E+09 | 0.00 | 963997.13 | 0.00 | 0.00 | 0.107702E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.606754E+09 | 0.137179E+11 | 0.00 | 4967694.22 | 216738.07 | 0.00 | 0.528949E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 45427442.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.244424E+09 | 0.267406E+10 | 0.00 | 1323102.28 | 78403.09 | 0.00 | 0.135847E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.244085E+09 | 45271188.21 | 0.00 | 1328257.59 | 70158.96 | 0.00 | 0.136468E+09 | 0.00 | 0.35 |
| February | 0.142279E+09 | 0.110343E+09 | 0.00 | 988141.06 | 0.00 | 0.00 | 0.107312E+09 | 0.00 | 0.36 |
| March | 69393969.95 | 0.248435E+09 | 0.00 | 884314.14 | 77464.27 | 0.00 | 98985050.93 | 0.00 | 0.36 |
| April | 9198459.17 | 0.597882E+09 | 0.00 | 378701.95 | 67371.34 | 0.00 | 45310872.99 | 0.00 | 0.36 |
| May | 0.00 | 0.129485E+10 | 0.00 | 46243.80 | 0.00 | 0.00 | 1297473.12 | 0.00 | 0.36 |
| June | 0.00 | 0.192181E+10 | 0.00 | 2711.25 | 0.00 | 0.00 | 83904.42 | 0.00 | 0.36 |
| July | 0.00 | 0.253576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.267202E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.211738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.137740E+10 | 0.00 | 87482.64 | 0.00 | 0.00 | 3524523.99 | 0.00 | 0.36 |
| November | 9645260.69 | 0.600062E+09 | 0.00 | 303617.22 | 0.00 | 0.00 | 30136910.33 | 0.00 | 0.36 |
| December | 0.131809E+09 | 0.181206E+09 | 0.00 | 966529.81 | 0.00 | 0.00 | 0.107793E+09 | 0.00 | 0.36 |
| Annual Sum or Average | 0.606410E+09 | 0.137024E+11 | 0.00 | 4985999.46 | 214994.57 | 0.00 | 0.530911E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 45271188.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.244085E+09 | 0.267202E+10 | 0.00 | 1328257.59 | 77464.27 | 0.00 | 0.136468E+09 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:22
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.761677E+11 | 0.762378E+10 | 0.00 | 0.835754E+09 | 0.584874E+11 |
| February | 0.817860E+11 | 0.480406E+10 | 0.00 | 0.548291E+09 | 0.721288E+11 |
| March | 0.959775E+11 | 0.762423E+09 | 0.00 | 0.347554E+09 | 0.109060E+12 |
| April | 0.967588E+11 | -0.631254E+10 | 0.00 | -35450129.8 | 0.157159E+12 |
| May | 0.961320E+11 | -0.151520E+11 | 0.00 | -815023488.0 | 0.243384E+12 |
| June | 0.900057E+11 | -0.250810E+11 | 0.00 | -0.149023E+10 | 0.294151E+12 |
| July | 0.891198E+11 | -0.315826E+11 | 0.00 | -0.224289E+10 | 0.353727E+12 |
| August | 0.889326E+11 | -0.339731E+11 | 0.00 | -0.249887E+10 | 0.369758E+12 |
| September | 0.820599E+11 | -0.253677E+11 | 0.00 | -0.169757E+10 | 0.305469E+12 |
| October | 0.739588E+11 | -0.140276E+11 | 0.00 | -923118574.6 | 0.241430E+12 |
| November | 0.636041E+11 | -0.521580E+10 | 0.00 | -86880353.7 | 0.159246E+12 |
| December | 0.659977E+11 | 0.347992E+10 | 0.00 | 0.580326E+09 | 0.898864E+11 |
| Annual Sum or Average | 0.100050E+13 | -0.140042E+12 | 0.00 | -0.747811E+10 | 0.245389E+13 |
| Minimum of Months | 0.636041E+11 | -0.339731E+11 | 0.00 | -0.249887E+10 | 0.584874E+11 |
| Maximum of Months | 0.967588E+11 | 0.762378E+10 | 0.00 | 0.835754E+09 | 0.369758E+12 |