Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Simulation Timestamp: 2023-10-16 09:14:37
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1854.32 | 591.56 | 656.63 |
| Net Site Energy | 1854.32 | 591.56 | 656.63 |
| Total Source Energy | 4651.62 | 1483.95 | 1647.19 |
| Net Source Energy | 4651.62 | 1483.95 | 1647.19 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 586.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 68.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 49.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 96.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 495.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1268.14 | 586.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 586.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 68.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 49.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 96.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 495.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 586.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 68.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 49.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 96.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 495.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 233.83 | 207.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 449.06 | 207.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 210.65 | 187.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 404.56 | 187.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1268.144 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1268.144 | 100.00 |
| Total On-Site and Utility Electric Sources | 1268.144 | 100.00 |
| Total Electricity End Uses | 1268.144 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 50.38 |
| Air to Air Heat Recovery for Heating | 0.00 | 49.62 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8668.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
| Latitude [deg] | 47.47 |
| Longitude [deg] | -111.4 |
| Elevation [m] | 1117.00 |
| Time Zone | -7.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 17-JUL-17:40 | 10-JAN-23:10 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 141409.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 25204.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 5231.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22609.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 8899.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 25525.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 87470.23 | 141409.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 141409.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 25204.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4887.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 344.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18441.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 8899.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 25525.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 635.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 215.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 305.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1569.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 4016.21 | 635.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 225.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 76.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 56.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 108.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 555.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1422.18 | 225.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 202.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 68.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 97.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 500.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1281.25 | 202.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.404120 |
| SPLIT GNW SUPPLY FAN | 0.369910 |
| SPLIT OFFICE SUPPLY FAN | 0.424091 |
| SPLIT GNE SUPPLY FAN | 0.326065 |
| SPLIT GN1 SUPPLY FAN | 0.293913 |
| SPLIT GN2 SUPPLY FAN | 0.293200 |
| SPLIT GS1 SUPPLY FAN | 0.331294 |
| SPLIT GS2 SUPPLY FAN | 0.333420 |
| SPLIT MSW SUPPLY FAN | 1.02 |
| SPLIT MNW SUPPLY FAN | 0.964007 |
| SPLIT MSE SUPPLY FAN | 0.882071 |
| SPLIT MNE SUPPLY FAN | 0.825695 |
| SPLIT MN1 SUPPLY FAN | 0.733713 |
| SPLIT MN2 SUPPLY FAN | 0.731660 |
| SPLIT MS1 SUPPLY FAN | 0.799246 |
| SPLIT MS2 SUPPLY FAN | 0.797004 |
| SPLIT TSW SUPPLY FAN | 0.569150 |
| SPLIT TNW SUPPLY FAN | 0.549891 |
| SPLIT TSE SUPPLY FAN | 0.467250 |
| SPLIT TNE SUPPLY FAN | 0.448191 |
| SPLIT TN1 SUPPLY FAN | 0.416419 |
| SPLIT TN2 SUPPLY FAN | 0.413543 |
| SPLIT TS1 SUPPLY FAN | 0.437858 |
| SPLIT TS2 SUPPLY FAN | 0.434981 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.404120 |
| G NW APARTMENT DIRECT AIR | 0.369910 |
| OFFICE DIRECT AIR | 0.424091 |
| G NE APARTMENT DIRECT AIR | 0.326065 |
| G N1 APARTMENT DIRECT AIR | 0.293913 |
| G N2 APARTMENT DIRECT AIR | 0.293200 |
| G S1 APARTMENT DIRECT AIR | 0.331294 |
| G S2 APARTMENT DIRECT AIR | 0.333420 |
| M SW APARTMENT DIRECT AIR | 1.02 |
| M NW APARTMENT DIRECT AIR | 0.964007 |
| M SE APARTMENT DIRECT AIR | 0.882071 |
| M NE APARTMENT DIRECT AIR | 0.825695 |
| M N1 APARTMENT DIRECT AIR | 0.733713 |
| M N2 APARTMENT DIRECT AIR | 0.731660 |
| M S1 APARTMENT DIRECT AIR | 0.799246 |
| M S2 APARTMENT DIRECT AIR | 0.797004 |
| T SW APARTMENT DIRECT AIR | 0.569150 |
| T NW APARTMENT DIRECT AIR | 0.549891 |
| T SE APARTMENT DIRECT AIR | 0.467250 |
| T NE APARTMENT DIRECT AIR | 0.448191 |
| T N1 APARTMENT DIRECT AIR | 0.416419 |
| T N2 APARTMENT DIRECT AIR | 0.413543 |
| T S1 APARTMENT DIRECT AIR | 0.437858 |
| T S2 APARTMENT DIRECT AIR | 0.434981 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.404120 | 0.404120 | 0.404120 | 0.404120 | 0.404120 | 0.404120 | 1.00 | 1.00 | 0.404120 |
| SPLIT GNW | 0.369910 | 0.369910 | 0.369910 | 0.369910 | 0.369910 | 0.369910 | 1.00 | 1.00 | 0.369910 |
| SPLIT OFFICE | 0.424091 | 0.424091 | 0.424091 | 0.424091 | 0.424091 | 0.424091 | 1.00 | 1.00 | 0.424091 |
| SPLIT GNE | 0.326065 | 0.326065 | 0.326065 | 0.326065 | 0.326065 | 0.326065 | 1.00 | 1.00 | 0.326065 |
| SPLIT GN1 | 0.293913 | 0.293913 | 0.293913 | 0.293913 | 0.293913 | 0.293913 | 1.00 | 1.00 | 0.293913 |
| SPLIT GN2 | 0.293200 | 0.293200 | 0.293200 | 0.293200 | 0.293200 | 0.293200 | 1.00 | 1.00 | 0.293200 |
| SPLIT GS1 | 0.331294 | 0.331294 | 0.331294 | 0.331294 | 0.331294 | 0.331294 | 1.00 | 1.00 | 0.331294 |
| SPLIT GS2 | 0.333420 | 0.333420 | 0.333420 | 0.333420 | 0.333420 | 0.333420 | 1.00 | 1.000000 | 0.333420 |
| SPLIT MSW | 1.02 | 1.02 | 1.02 | 1.02 | 1.02 | 1.02 | 1.00 | 1.00 | 1.02 |
| SPLIT MNW | 0.964007 | 0.964007 | 0.964007 | 0.964007 | 0.964007 | 0.964007 | 1.00 | 1.000000 | 0.964007 |
| SPLIT MSE | 0.882071 | 0.882071 | 0.882071 | 0.882071 | 0.882071 | 0.882071 | 1.00 | 1.00 | 0.882071 |
| SPLIT MNE | 0.825695 | 0.825695 | 0.825695 | 0.825695 | 0.825695 | 0.825695 | 1.00 | 1.00 | 0.825695 |
| SPLIT MN1 | 0.733713 | 0.733713 | 0.733713 | 0.733713 | 0.733713 | 0.733713 | 1.00 | 1.00 | 0.733713 |
| SPLIT MN2 | 0.731660 | 0.731660 | 0.731660 | 0.731660 | 0.731660 | 0.731660 | 1.00 | 1.00 | 0.731660 |
| SPLIT MS1 | 0.799246 | 0.799246 | 0.799246 | 0.799246 | 0.799246 | 0.799246 | 1.00 | 1.00 | 0.799246 |
| SPLIT MS2 | 0.797004 | 0.797004 | 0.797004 | 0.797004 | 0.797004 | 0.797004 | 1.00 | 1.00 | 0.797004 |
| SPLIT TSW | 0.569150 | 0.569150 | 0.569150 | 0.569150 | 0.569150 | 0.569150 | 1.00 | 1.00 | 0.569150 |
| SPLIT TNW | 0.549891 | 0.549891 | 0.549891 | 0.549891 | 0.549891 | 0.549891 | 1.00 | 1.00 | 0.549891 |
| SPLIT TSE | 0.467250 | 0.467250 | 0.467250 | 0.467250 | 0.467250 | 0.467250 | 1.00 | 1.00 | 0.467250 |
| SPLIT TNE | 0.448191 | 0.448191 | 0.448191 | 0.448191 | 0.448191 | 0.448191 | 1.00 | 1.00 | 0.448191 |
| SPLIT TN1 | 0.416419 | 0.416419 | 0.416419 | 0.416419 | 0.416419 | 0.416419 | 1.00 | 1.00 | 0.416419 |
| SPLIT TN2 | 0.413543 | 0.413543 | 0.413543 | 0.413543 | 0.413543 | 0.413543 | 1.00 | 1.00 | 0.413543 |
| SPLIT TS1 | 0.437858 | 0.437858 | 0.437858 | 0.437858 | 0.437858 | 0.437858 | 1.00 | 1.00 | 0.437858 |
| SPLIT TS2 | 0.434981 | 0.434981 | 0.434981 | 0.434981 | 0.434981 | 0.434981 | 1.00 | 1.00 | 0.434981 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.404120 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.369910 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.424091 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.326065 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.293913 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.293200 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.331294 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.333420 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 1.02 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.964007 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.882071 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.825695 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.733713 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.731660 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.799246 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.797004 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.569150 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.549891 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.467250 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.448191 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.416419 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.413543 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.437858 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.434981 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.404120 | 0.404120 | 0.404120 | 0.404120 | 6689.62 | 9420.64 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.369910 | 0.369910 | 0.369910 | 0.369910 | 6123.32 | 8736.33 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.424091 | 0.424091 | 0.424091 | 0.424091 | 7020.21 | 10446.33 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.326065 | 0.326065 | 0.326065 | 0.326065 | 5397.54 | 7859.38 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.293913 | 0.293913 | 0.293913 | 0.293913 | 4865.30 | 7216.23 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.293200 | 0.293200 | 0.293200 | 0.293200 | 4853.49 | 7201.97 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.331294 | 0.331294 | 0.331294 | 0.331294 | 5484.09 | 7963.94 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.333420 | 0.333420 | 0.333420 | 0.333420 | 5519.28 | 8006.46 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 1.02 | 1.02 | 1.02 | 1.02 | 16925.86 | 23127.52 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.964007 | 0.964007 | 0.964007 | 0.964007 | 15957.73 | 21957.37 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.882071 | 0.882071 | 0.882071 | 0.882071 | 14601.40 | 20318.77 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.825695 | 0.825695 | 0.825695 | 0.825695 | 13668.19 | 19190.85 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.733713 | 0.733713 | 0.733713 | 0.733713 | 12145.56 | 17350.65 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.731660 | 0.731660 | 0.731660 | 0.731660 | 12111.57 | 17309.59 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.799246 | 0.799246 | 0.799246 | 0.799246 | 13230.35 | 18661.68 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.797004 | 0.797004 | 0.797004 | 0.797004 | 13193.24 | 18616.84 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.569150 | 0.569150 | 0.569150 | 0.569150 | 9421.46 | 12722.27 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.549891 | 0.549891 | 0.549891 | 0.549891 | 9102.64 | 12336.83 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.467250 | 0.467250 | 0.467250 | 0.467250 | 7734.65 | 10683.96 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.448191 | 0.448191 | 0.448191 | 0.448191 | 7419.16 | 10302.58 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.416419 | 0.416419 | 0.416419 | 0.416419 | 6893.21 | 9666.76 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.413543 | 0.413543 | 0.413543 | 0.413543 | 6845.60 | 9609.24 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.437858 | 0.437858 | 0.437858 | 0.437858 | 7248.10 | 10095.73 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.434981 | 0.434981 | 0.434981 | 0.434981 | 7200.48 | 10038.19 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.404120 | 6689.62 | 0.800655 |
| SPLIT GNW COOLING COIL | 0.369910 | 6123.32 | 0.800655 |
| SPLIT OFFICE COOLING COIL | 0.424091 | 7020.21 | 0.800655 |
| SPLIT GNE COOLING COIL | 0.326065 | 5397.54 | 0.800655 |
| SPLIT GN1 COOLING COIL | 0.293913 | 4865.30 | 0.800655 |
| SPLIT GN2 COOLING COIL | 0.293200 | 4853.49 | 0.800655 |
| SPLIT GS1 COOLING COIL | 0.331294 | 5484.09 | 0.800655 |
| SPLIT GS2 COOLING COIL | 0.333420 | 5519.28 | 0.800655 |
| SPLIT MSW COOLING COIL | 1.02 | 16925.86 | 0.800655 |
| SPLIT MNW COOLING COIL | 0.964007 | 15957.73 | 0.800655 |
| SPLIT MSE COOLING COIL | 0.882071 | 14601.40 | 0.800655 |
| SPLIT MNE COOLING COIL | 0.825695 | 13668.19 | 0.800655 |
| SPLIT MN1 COOLING COIL | 0.733713 | 12145.56 | 0.800655 |
| SPLIT MN2 COOLING COIL | 0.731660 | 12111.57 | 0.800655 |
| SPLIT MS1 COOLING COIL | 0.799246 | 13230.35 | 0.800655 |
| SPLIT MS2 COOLING COIL | 0.797004 | 13193.24 | 0.800655 |
| SPLIT TSW COOLING COIL | 0.569150 | 9421.46 | 0.800655 |
| SPLIT TNW COOLING COIL | 0.549891 | 9102.64 | 0.800655 |
| SPLIT TSE COOLING COIL | 0.467250 | 7734.65 | 0.800655 |
| SPLIT TNE COOLING COIL | 0.448191 | 7419.16 | 0.800655 |
| SPLIT TN1 COOLING COIL | 0.416419 | 6893.21 | 0.800655 |
| SPLIT TN2 COOLING COIL | 0.413543 | 6845.60 | 0.800655 |
| SPLIT TS1 COOLING COIL | 0.437858 | 7248.10 | 0.800655 |
| SPLIT TS2 COOLING COIL | 0.434981 | 7200.48 | 0.800655 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 9420.64 |
| SPLIT GNW HEATING COIL | 8736.33 |
| SPLIT OFFICE HEATING COIL | 10446.33 |
| SPLIT GNE HEATING COIL | 7859.38 |
| SPLIT GN1 HEATING COIL | 7216.23 |
| SPLIT GN2 HEATING COIL | 7201.97 |
| SPLIT GS1 HEATING COIL | 7963.94 |
| SPLIT GS2 HEATING COIL | 8006.46 |
| SPLIT MSW HEATING COIL | 23127.52 |
| SPLIT MNW HEATING COIL | 21957.37 |
| SPLIT MSE HEATING COIL | 20318.77 |
| SPLIT MNE HEATING COIL | 19190.85 |
| SPLIT MN1 HEATING COIL | 17350.65 |
| SPLIT MN2 HEATING COIL | 17309.59 |
| SPLIT MS1 HEATING COIL | 18661.68 |
| SPLIT MS2 HEATING COIL | 18616.84 |
| SPLIT TSW HEATING COIL | 12722.27 |
| SPLIT TNW HEATING COIL | 12336.83 |
| SPLIT TSE HEATING COIL | 10683.96 |
| SPLIT TNE HEATING COIL | 10302.58 |
| SPLIT TN1 HEATING COIL | 9666.76 |
| SPLIT TN2 HEATING COIL | 9609.24 |
| SPLIT TS1 HEATING COIL | 10095.73 |
| SPLIT TS2 HEATING COIL | 10038.19 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 8.60 | 2.80 | -4.10 | -8.80 | -2.20 | 0.30 | 6.70 | 10.10 | 16.50 | 20.60 | 19.20 | 14.70 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 | 47.47 | -111.38 | -7.00 | 1117.00 | 88606 | 1.0531 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 7.03 | 29.40 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 6.623E-005 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 4156.07527 | 4987.29033 | 0.33677 | 0.40412 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 2926.74172 | 3512.09006 | 0.14419 | 0.17303 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3812.05841 | 4574.47009 | 0.30826 | 0.36991 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 2785.76961 | 3342.92354 | 0.13725 | 0.16470 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4306.44685 | 5167.73622 | 0.35341 | 0.42409 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 24.60000 | 6.29334E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 3457.51333 | 4149.01600 | 0.17034 | 0.20441 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 3369.39261 | 4043.27114 | 0.27172 | 0.32607 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 2774.91355 | 3329.89626 | 0.13672 | 0.16406 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 3045.38769 | 3654.46523 | 0.24493 | 0.29391 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 1798.44389 | 2158.13267 | 8.86070E-002 | 0.10633 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 3038.22900 | 3645.87479 | 0.24433 | 0.29320 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 1798.14263 | 2157.77116 | 8.85922E-002 | 0.10631 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3422.87223 | 4107.44667 | 0.27608 | 0.33129 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 1941.26216 | 2329.51459 | 9.56428E-002 | 0.11477 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3444.24896 | 4133.09875 | 0.27785 | 0.33342 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 1950.95030 | 2341.14036 | 9.61201E-002 | 0.11534 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 10477.02724 | 12572.43268 | 0.85208 | 1.02249 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 4888.67017 | 5866.40421 | 0.24084 | 0.28901 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 9886.27539 | 11863.53047 | 0.80334 | 0.96401 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 4553.73608 | 5464.48329 | 0.22435 | 0.26922 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 9058.62994 | 10870.35593 | 0.73506 | 0.88207 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 4862.92226 | 5835.50671 | 0.23957 | 0.28749 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 8488.51906 | 10186.22288 | 0.68808 | 0.82570 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 4527.98402 | 5433.58082 | 0.22308 | 0.26769 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 7562.77835 | 9075.33402 | 0.61143 | 0.73371 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 2518.90747 | 3022.68896 | 0.12410 | 0.14892 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 7542.17515 | 9050.61018 | 0.60972 | 0.73166 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 2518.27507 | 3021.93009 | 0.12407 | 0.14888 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 8222.37587 | 9866.85104 | 0.66604 | 0.79925 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 2848.34126 | 3418.00951 | 0.14033 | 0.16839 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 8199.79682 | 9839.75619 | 0.66417 | 0.79700 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 2847.71608 | 3417.25930 | 0.14030 | 0.16836 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5823.29769 | 6987.95723 | 0.47429 | 0.56915 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 3992.28236 | 4790.73883 | 0.19668 | 0.23601 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 5628.75742 | 6754.50891 | 0.45824 | 0.54989 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 3807.02509 | 4568.43011 | 0.18755 | 0.22506 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4797.47716 | 5756.97259 | 0.38938 | 0.46725 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 3974.22457 | 4769.06949 | 0.19579 | 0.23495 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 4604.76010 | 5525.71212 | 0.37349 | 0.44819 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 3788.92511 | 4546.71013 | 0.18666 | 0.22399 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 4282.89358 | 5139.47229 | 0.34702 | 0.41642 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 2586.31862 | 3103.58234 | 0.12742 | 0.15290 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 4253.84143 | 5104.60972 | 0.34462 | 0.41354 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 2585.84673 | 3103.01608 | 0.12740 | 0.15288 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4500.90543 | 5401.08652 | 0.36488 | 0.43786 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 2772.22770 | 3326.67323 | 0.13658 | 0.16389 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4471.78033 | 5366.13639 | 0.36248 | 0.43498 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.16000 | 6.29721E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 2771.76131 | 3326.11358 | 0.13655 | 0.16386 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -27.60000 | 3.41898E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4896.03 | 0.40412 | 0.40412 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 4798.54 | 0.17303 | 0.17303 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4486.88 | 0.36991 | 0.36991 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 4631.84 | 0.16470 | 0.16470 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5033.74 | 0.42409 | 0.42409 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 6052.44 | 0.20441 | 0.20441 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 3961.70 | 0.32607 | 0.32607 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 4619.01 | 0.16406 | 0.16406 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3576.44 | 0.29391 | 0.29391 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 3464.32 | 0.10633 | 0.10633 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3567.90 | 0.29320 | 0.29320 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 3463.96 | 0.10631 | 0.10631 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 4024.94 | 0.33129 | 0.33129 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 3633.20 | 0.11477 | 0.11477 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 4050.29 | 0.33342 | 0.33342 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 3644.65 | 0.11534 | 0.11534 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 12357.06 | 1.02249 | 1.02249 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 8456.13 | 0.28901 | 0.28901 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 11657.31 | 0.96401 | 0.96401 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 8060.08 | 0.26922 | 0.26922 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 10676.79 | 0.88207 | 0.88207 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 8425.68 | 0.28749 | 0.28749 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 10001.37 | 0.82570 | 0.82570 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 8029.62 | 0.26769 | 0.26769 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 8901.18 | 0.73371 | 0.73371 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 5653.88 | 0.14892 | 0.14892 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 8876.66 | 0.73166 | 0.73166 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 5653.13 | 0.14888 | 0.14888 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9685.38 | 0.79925 | 0.79925 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 6043.42 | 0.16839 | 0.16839 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9658.58 | 0.79700 | 0.79700 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 6042.68 | 0.16836 | 0.16836 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6871.22 | 0.56915 | 0.56915 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 6058.53 | 0.23601 | 0.23601 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 6640.92 | 0.54989 | 0.54989 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 5839.47 | 0.22506 | 0.22506 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 5654.23 | 0.46725 | 0.46725 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 6037.18 | 0.23495 | 0.23495 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 5426.14 | 0.44819 | 0.44819 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 5818.07 | 0.22399 | 0.22399 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 5045.46 | 0.41642 | 0.41642 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 4395.98 | 0.15290 | 0.15290 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 5011.05 | 0.41354 | 0.41354 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 4395.42 | 0.15288 | 0.15288 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5302.78 | 0.43786 | 0.43786 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 4615.81 | 0.16389 | 0.16389 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5268.33 | 0.43498 | 0.43498 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 4615.26 | 0.16386 | 0.16386 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.40412 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36991 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42409 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.32607 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29391 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29320 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33129 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33342 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.02249 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.96401 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.88207 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.82570 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.73371 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.73166 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.79925 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.79700 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.56915 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.54989 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.46725 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.44819 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.41642 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.41354 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.43786 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.43498 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.40412 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.40412 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.40412 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.40412 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.40412 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.40412 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36991 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36991 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36991 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36991 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36991 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.36991 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42409 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42409 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42409 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42409 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42409 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.42409 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.32607 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.32607 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.32607 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.32607 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.32607 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.32607 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29391 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29391 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29391 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29391 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29391 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29391 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29320 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29320 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29320 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29320 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29320 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29320 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33129 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33129 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33129 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33129 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33129 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.33129 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33342 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33342 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33342 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33342 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33342 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.33342 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.02249 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.02249 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.02249 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 1.02249 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.02249 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 1.02249 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.96401 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.96401 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.96401 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.96401 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.96401 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.96401 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.88207 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.88207 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.88207 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.88207 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.88207 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.88207 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.82570 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.82570 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.82570 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.82570 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.82570 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.82570 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.73371 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.73371 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.73371 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.73371 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.73371 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.73371 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.73166 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.73166 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.73166 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.73166 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.73166 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.73166 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.79925 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.79925 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.79925 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.79925 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.79925 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.79925 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.79700 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.79700 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.79700 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.79700 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.79700 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.79700 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.56915 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.56915 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.56915 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.56915 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.56915 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.56915 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.54989 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.54989 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.54989 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.54989 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.54989 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.54989 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.46725 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.46725 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.46725 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.46725 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.46725 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.46725 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.44819 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.44819 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.44819 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.44819 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.44819 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.44819 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.41642 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.41642 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.41642 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.41642 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.41642 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.41642 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.41354 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.41354 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.41354 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.41354 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.41354 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.41354 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.43786 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.43786 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.43786 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.43786 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.43786 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.43786 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.43498 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.43498 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.43498 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.43498 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.43498 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.43498 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.40412 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.36991 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.42409 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.32607 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.29391 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.29320 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.33129 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.33342 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 1.02249 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.96401 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.88207 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.82570 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.73371 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.73166 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.79925 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.79700 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.56915 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.54989 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.46725 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.44819 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.41642 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.41354 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.43786 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.43498 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.40412 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.40412 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.40412 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.40412 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.40412 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6689.62458 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9420.63682 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.40412 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.40412 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6689.62458 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 9420.63682 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36991 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36991 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36991 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36991 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36991 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6123.31825 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8736.32875 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36991 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36991 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6123.31825 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 8736.32875 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42409 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42409 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42409 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42409 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42409 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7020.21475 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10446.33335 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42409 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42409 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7020.21475 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 10446.33335 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.32607 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.32607 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.32607 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.32607 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.32607 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5397.53951 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7859.38092 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.32607 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32607 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5397.53951 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 7859.38092 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29391 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29391 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29391 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29391 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29391 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4865.30201 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7216.23316 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29391 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29391 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4865.30201 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 7216.23316 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29320 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29320 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29320 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29320 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29320 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4853.49483 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7201.96686 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29320 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29320 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4853.49483 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 7201.96686 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33129 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33129 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33129 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33129 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33129 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5484.08753 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7963.94060 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33129 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33129 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5484.08753 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 7963.94060 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33342 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33342 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33342 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33342 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33342 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5519.27713 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8006.45953 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33342 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33342 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5519.27713 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 8006.45953 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.02249 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.02249 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.02249 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.02249 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.02249 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 16925.85762 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 23127.52301 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 1.02249 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 1.02249 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 16925.85762 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 23127.52301 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.96401 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.96401 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.96401 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.96401 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.96401 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 15957.73224 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 21957.37222 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.96401 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.96401 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 15957.73224 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 21957.37222 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.88207 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.88207 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.88207 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.88207 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.88207 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14601.40258 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20318.76915 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.88207 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.88207 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14601.40258 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 20318.76915 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.82570 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.82570 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.82570 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.82570 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.82570 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13668.18770 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 19190.85041 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.82570 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.82570 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13668.18770 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 19190.85041 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.73371 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.73371 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.73371 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.73371 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.73371 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12145.55838 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17350.64921 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.73371 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.73371 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12145.55838 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 17350.64921 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.73166 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.73166 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.73166 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.73166 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.73166 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12111.57474 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17309.58693 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.73166 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.73166 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12111.57474 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 17309.58693 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.79925 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.79925 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.79925 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.79925 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.79925 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13230.35195 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18661.67912 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.79925 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.79925 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13230.35195 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 18661.67912 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.79700 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.79700 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.79700 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.79700 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.79700 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13193.24114 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18616.83746 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.79700 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.79700 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13193.24114 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 18616.83746 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.56915 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.56915 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.56915 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.56915 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.56915 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9421.45680 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 12722.26507 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.56915 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.56915 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9421.45680 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 12722.26507 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.54989 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.54989 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.54989 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.54989 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.54989 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9102.64374 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 12336.83253 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.54989 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.54989 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9102.64374 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 12336.83253 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.46725 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.46725 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.46725 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.46725 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.46725 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7734.64848 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10683.96119 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.46725 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.46725 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7734.64848 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 10683.96119 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.44819 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.44819 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.44819 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.44819 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.44819 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7419.15781 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10302.57930 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.44819 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44819 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7419.15781 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 10302.57930 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.41642 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.41642 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.41642 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.41642 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.41642 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6893.20503 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9666.75703 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.41642 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.41642 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6893.20503 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 9666.75703 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.41354 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.41354 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.41354 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.41354 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.41354 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6845.60484 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9609.24105 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.41354 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.41354 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6845.60484 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 9609.24105 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.43786 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.43786 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.43786 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.43786 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.43786 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7248.09810 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10095.73286 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.43786 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.43786 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7248.09810 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 10095.73286 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.43498 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.43498 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.43498 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.43498 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.43498 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7200.47636 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10038.18978 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.43498 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.43498 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7200.47636 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 10038.18978 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 6372.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 5833.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 6687.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 5142.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 4635.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 4623.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 5224.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 5258.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 16124.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 15202.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 13910.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 13021.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 11570.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 11538.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 12604.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 12568.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 8975.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 8671.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 7368.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 7067.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 6566.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 6521.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 6905.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 6859.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.202 | 0.193 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.202 | 0.193 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.202 | 0.193 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.202 | 0.193 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.120 | 0.117 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.120 | 0.117 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.120 | 0.117 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.703 | 0.636 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.120 | 0.117 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.712 | 0.643 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.045 | 0.903 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 3.909E-002 | 3.873E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3772_SHGC_0.4 | N/A | 2.143 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 8.9501578966E-003 | 2.2248920577E-002 | Pass | Pass | 0.1795548329 | 0.5821655163 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1773503372E-007 | 7.0900868998E-007 | Pass | Pass | 2.4456428542E-002 | 3.0273579954E-002 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 4.2465522081E-002 | 3.4450365871E-002 | Pass | Pass | 4.8166094038E-002 | 4.2666049157E-002 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0784976401E-007 | 6.4311856435E-007 | Pass | Pass | 2.3448893332E-002 | 3.1305658198E-002 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.8086700572E-008 | 3.4188722147E-007 | Pass | Pass | 0.1542730490 | 0.7356298646 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.7817795624E-008 | 3.4051332869E-007 | Pass | Pass | 0.1607786436 | 0.7860179554 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.8923341699E-002 | 2.5558990178E-002 | Pass | Pass | 5.3823484970E-002 | 7.9785619895E-002 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6298999580E-002 | 2.5064773051E-002 | Pass | Pass | 0.2103536296 | 0.5756193818 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.9093829091E-002 | 3.4778606147E-002 | Pass | Pass | 0.2015421124 | 0.8171984708 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.8637935396E-008 | 3.9287855382E-007 | Pass | Pass | 0.2559589082 | 0.7540487302 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.9346681259E-002 | 3.4677857296E-002 | Pass | Pass | 0.1477713906 | 0.5460069789 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 4.7858119393E-008 | 3.1829235018E-007 | Pass | Pass | 0.2165451408 | 0.8433689535 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0500705393E-008 | 1.7618870328E-007 | Pass | Pass | 0.6699916197 | 6.4367051081 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0427693673E-008 | 1.7658729135E-007 | Pass | Pass | 0.3251034677 | 1.9221337833 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0059727671E-002 | 3.3135643497E-002 | Pass | Pass | 9.1538139039E-003 | 9.5972776105E-003 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0347403459E-002 | 3.3204814665E-002 | Pass | Pass | 9.0131222884E-003 | 9.0630801879E-003 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.3427588322E-002 | 5.8319992857E-002 | Pass | Pass | 0.1379887821 | 0.3603124345 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6005390948E-007 | 9.6789312029E-007 | Pass | Pass | 3.1962617776E-002 | 3.1481992513E-002 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.2776325747E-002 | 5.5677636773E-002 | Pass | Pass | 0.1399137287 | 0.3871090571 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.4766392390E-007 | 8.7537357232E-007 | Pass | Pass | 2.7690939390E-002 | 2.7121196504E-002 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 9.4567008866E-008 | 6.4419301900E-007 | Pass | Pass | 5.0110610104E-002 | 7.5543331292E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 9.4410048470E-008 | 6.4290862814E-007 | Pass | Pass | 5.0111092425E-002 | 7.4843933012E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0345287133E-002 | 5.9817185914E-002 | Pass | Pass | 0.1280666345 | 0.6621759474 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.0277971524E-002 | 6.0182833897E-002 | Pass | Pass | 0.1065952122 | 0.4146530671 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 2.8546929911E-002 | 2.0012202430E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.2058192745 | 0.6690822431 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 9.9659091069E-003 | 8.0127244786E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1945.22 | 201.42 | 0.00 | 19.35 | 441.98 | 2607.98 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | -27.60 | 0.00 | -27.60 | Wetbulb [C] | 2.70 | 230.00 |
| GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 33.40 | 16.00 | 16.30 | Wetbulb [C] | 4.90 | 240.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 0.00 | 0 | |||
| Feb | 0.00 | 0 | |||
| Mar | 0.00 | 0 | |||
| Apr | 11.00 | 18 | |||
| May | 24.00 | 14 | |||
| Jun | 29.00 | 21 | |||
| Jul | 6.00 | 9 | |||
| Aug | 0.00 | 0 | |||
| Sep | 0.00 | 0 | |||
| Oct | 0.00 | 0 | |||
| Nov | 0.00 | 0 | |||
| Dec | 0.00 | 0 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.196 | 0.202 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.196 | 0.202 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.196 | 0.202 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.196 | 0.202 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.118 | 0.120 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.118 | 0.120 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.118 | 0.120 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.636 | 0.703 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.118 | 0.120 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.643 | 0.712 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.903 | 1.045 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.30 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.30 | 0.182 | 0.186 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.039 | 0.039 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.143 | 0.401 | 0.402 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.143 | 0.401 | 0.402 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.143 | 0.401 | 0.402 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.143 | 0.401 | 0.402 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.143 | 0.401 | 0.402 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.3772_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.143 | 0.401 | 0.402 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.3772_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.143 | 0.401 | 0.402 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.3772_SHGC_0.4 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.143 | 0.401 | 0.402 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.3772_SHGC_0.4 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.143 | 0.401 | 0.402 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.3772_SHGC_0.4 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.143 | 0.401 | 0.402 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 2.143 | 0.401 | 0.402 | |||||||||||||||||
| North Total or Average | 112.97 | 2.143 | 0.401 | 0.402 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 2.143 | 0.401 | 0.402 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.57 | 83.57 | 49.94 | |
| Exterior Lighting Total | 3183.33 | 49.94 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6689.62 | 5356.08 | 1333.54 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6123.32 | 4902.67 | 1220.65 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7020.21 | 5620.77 | 1399.44 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5397.54 | 4321.57 | 1075.97 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4865.30 | 3895.43 | 969.87 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4853.49 | 3885.98 | 967.52 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5484.09 | 4390.86 | 1093.22 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5519.28 | 4419.04 | 1100.24 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 16925.86 | 13551.78 | 3374.08 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 15957.73 | 12776.64 | 3181.09 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14601.40 | 11690.69 | 2910.71 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13668.19 | 10943.51 | 2724.68 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12145.56 | 9724.41 | 2421.15 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12111.57 | 9697.20 | 2414.38 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13230.35 | 10592.95 | 2637.40 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13193.24 | 10563.24 | 2630.00 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9421.46 | 7543.34 | 1878.12 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9102.64 | 7288.08 | 1814.56 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7734.65 | 6192.79 | 1541.86 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7419.16 | 5940.19 | 1478.97 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6893.21 | 5519.08 | 1374.12 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6845.60 | 5480.97 | 1364.64 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7248.10 | 5803.23 | 1444.87 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7200.48 | 5765.10 | 1435.38 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 6372.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNW COOLING COIL | 5833.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT OFFICE COOLING COIL | 6687.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNE COOLING COIL | 5142.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN1 COOLING COIL | 4635.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN2 COOLING COIL | 4623.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS1 COOLING COIL | 5224.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS2 COOLING COIL | 5258.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSW COOLING COIL | 16124.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNW COOLING COIL | 15202.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSE COOLING COIL | 13910.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNE COOLING COIL | 13021.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN1 COOLING COIL | 11570.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN2 COOLING COIL | 11538.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS1 COOLING COIL | 12604.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS2 COOLING COIL | 12568.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSW COOLING COIL | 8975.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNW COOLING COIL | 8671.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSE COOLING COIL | 7368.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNE COOLING COIL | 7067.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN1 COOLING COIL | 6566.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN2 COOLING COIL | 6521.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS1 COOLING COIL | 6905.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS2 COOLING COIL | 6859.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 9420.64 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 8736.33 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 10446.33 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 7859.38 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 7216.23 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 7201.97 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 7963.94 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 8006.46 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 23127.52 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 21957.37 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 20318.77 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 19190.85 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 17350.65 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 17309.59 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 18661.68 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 18616.84 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 12722.27 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 12336.83 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 10683.96 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 10302.58 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 9666.76 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 9609.24 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 10095.73 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 10038.19 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 452.66 | 1120.11 | 1.00 | 1.71 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 414.34 | 1120.11 | 1.00 | 1.76 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 475.03 | 1120.11 | 1.00 | 1.69 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 12:00:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 365.23 | 1120.11 | 1.00 | 1.84 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 329.21 | 1120.11 | 1.00 | 1.91 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 328.42 | 1120.11 | 1.00 | 1.91 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 371.08 | 1120.11 | 1.00 | 1.83 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 373.47 | 1120.11 | 1.00 | 1.82 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 1.02 | 1145.30 | 1120.11 | 1.00 | 1.37 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.96 | 1079.79 | 1120.11 | 1.00 | 1.38 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.88 | 988.01 | 1120.11 | 1.00 | 1.41 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.83 | 924.87 | 1120.11 | 1.00 | 1.42 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.73 | 821.84 | 1120.11 | 1.00 | 1.46 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.73 | 819.54 | 1120.11 | 1.00 | 1.46 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.80 | 895.24 | 1120.11 | 1.00 | 1.43 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.80 | 892.73 | 1120.11 | 1.00 | 1.43 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.57 | 637.51 | 1120.11 | 1.00 | 1.55 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.55 | 615.94 | 1120.11 | 1.00 | 1.56 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.47 | 523.37 | 1120.11 | 1.00 | 1.64 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 502.02 | 1120.11 | 1.00 | 1.66 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 466.43 | 1120.11 | 1.00 | 1.69 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 463.21 | 1120.11 | 1.00 | 1.70 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.44 | 490.45 | 1120.11 | 1.00 | 1.67 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 487.23 | 1120.11 | 1.00 | 1.67 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 4156.08 | 4987.29 | 56.51 | 0.337 | 0.404 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00804 | 27.16 | 0.00630 | 0.026 | 0.00 |
| G NW APARTMENT | 3812.06 | 4574.47 | 51.84 | 0.308 | 0.370 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 27.16 | 0.00630 | 0.026 | 0.00 |
| OFFICE | 4306.45 | 5167.74 | 58.56 | 0.353 | 0.424 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.90 | 23.90 | 0.00795 | 24.60 | 0.00629 | 0.038 | 0.00 |
| G NE APARTMENT | 3369.39 | 4043.27 | 45.82 | 0.272 | 0.326 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 27.16 | 0.00630 | 0.026 | 0.00 |
| G N1 APARTMENT | 3045.39 | 3654.47 | 41.41 | 0.245 | 0.294 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00807 | 27.16 | 0.00630 | 0.026 | 0.00 |
| G N2 APARTMENT | 3038.23 | 3645.87 | 41.31 | 0.244 | 0.293 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00807 | 27.16 | 0.00630 | 0.026 | 0.00 |
| G S1 APARTMENT | 3422.87 | 4107.45 | 46.54 | 0.276 | 0.331 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 27.16 | 0.00630 | 0.026 | 0.00 |
| G S2 APARTMENT | 3444.25 | 4133.10 | 46.83 | 0.278 | 0.333 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00809 | 27.16 | 0.00630 | 0.026 | 0.00 |
| M SW APARTMENT | 10477.03 | 12572.43 | 142.46 | 0.852 | 1.022 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00801 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M NW APARTMENT | 9886.28 | 11863.53 | 134.43 | 0.803 | 0.964 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M SE APARTMENT | 9058.63 | 10870.36 | 123.18 | 0.735 | 0.882 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00802 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M NE APARTMENT | 8488.52 | 10186.22 | 115.43 | 0.688 | 0.826 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M N1 APARTMENT | 7562.78 | 9075.33 | 102.84 | 0.611 | 0.734 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00804 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M N2 APARTMENT | 7542.18 | 9050.61 | 102.56 | 0.610 | 0.732 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00804 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M S1 APARTMENT | 8222.38 | 9866.85 | 111.81 | 0.666 | 0.799 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00805 | 27.16 | 0.00630 | 0.052 | 0.00 |
| M S2 APARTMENT | 8199.80 | 9839.76 | 111.50 | 0.664 | 0.797 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00805 | 27.16 | 0.00630 | 0.052 | 0.00 |
| T SW APARTMENT | 5823.30 | 6987.96 | 79.18 | 0.474 | 0.569 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T NW APARTMENT | 5628.76 | 6754.51 | 76.54 | 0.458 | 0.550 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00799 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T SE APARTMENT | 4797.48 | 5756.97 | 65.24 | 0.389 | 0.467 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00800 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T NE APARTMENT | 4604.76 | 5525.71 | 62.61 | 0.373 | 0.448 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00799 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T N1 APARTMENT | 4282.89 | 5139.47 | 58.24 | 0.347 | 0.416 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00802 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T N2 APARTMENT | 4253.84 | 5104.61 | 57.84 | 0.345 | 0.414 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00802 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T S1 APARTMENT | 4500.91 | 5401.09 | 61.20 | 0.365 | 0.438 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 27.16 | 0.00630 | 0.026 | 0.00 |
| T S2 APARTMENT | 4471.78 | 5366.14 | 60.81 | 0.362 | 0.435 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00803 | 27.16 | 0.00630 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 2926.74 | 3512.09 | 39.80 | 0.144 | 0.173 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00770 | -27.60 | 0.00034 | 0.026 | 0.00 |
| G NW APARTMENT | 2785.77 | 3342.92 | 37.88 | 0.137 | 0.165 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00775 | -27.60 | 0.00034 | 0.026 | 0.00 |
| OFFICE | 3457.51 | 4149.02 | 47.01 | 0.170 | 0.204 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00775 | -27.60 | 0.00034 | 0.038 | 0.00 |
| G NE APARTMENT | 2774.91 | 3329.90 | 37.73 | 0.137 | 0.164 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00775 | -27.60 | 0.00034 | 0.026 | 0.00 |
| G N1 APARTMENT | 1798.44 | 2158.13 | 24.45 | 0.089 | 0.106 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00782 | -27.60 | 0.00034 | 0.026 | 0.00 |
| G N2 APARTMENT | 1798.14 | 2157.77 | 24.45 | 0.089 | 0.106 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00782 | -27.60 | 0.00034 | 0.026 | 0.00 |
| G S1 APARTMENT | 1941.26 | 2329.51 | 26.40 | 0.096 | 0.115 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00772 | -27.60 | 0.00034 | 0.026 | 0.00 |
| G S2 APARTMENT | 1950.95 | 2341.14 | 26.53 | 0.096 | 0.115 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00772 | -27.60 | 0.00034 | 0.026 | 0.00 |
| M SW APARTMENT | 4888.67 | 5866.40 | 66.48 | 0.241 | 0.289 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00750 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M NW APARTMENT | 4553.74 | 5464.48 | 61.92 | 0.224 | 0.269 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00760 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M SE APARTMENT | 4862.92 | 5835.51 | 66.13 | 0.240 | 0.287 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00750 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M NE APARTMENT | 4527.98 | 5433.58 | 61.57 | 0.223 | 0.268 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00760 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M N1 APARTMENT | 2518.91 | 3022.69 | 34.25 | 0.124 | 0.149 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00766 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M N2 APARTMENT | 2518.28 | 3021.93 | 34.24 | 0.124 | 0.149 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00766 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M S1 APARTMENT | 2848.34 | 3418.01 | 38.73 | 0.140 | 0.168 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00749 | -27.60 | 0.00034 | 0.052 | 0.00 |
| M S2 APARTMENT | 2847.72 | 3417.26 | 38.72 | 0.140 | 0.168 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00749 | -27.60 | 0.00034 | 0.052 | 0.00 |
| T SW APARTMENT | 3992.28 | 4790.74 | 54.29 | 0.197 | 0.236 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00759 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T NW APARTMENT | 3807.03 | 4568.43 | 51.77 | 0.188 | 0.225 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00765 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T SE APARTMENT | 3974.22 | 4769.07 | 54.04 | 0.196 | 0.235 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00759 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T NE APARTMENT | 3788.93 | 4546.71 | 51.52 | 0.187 | 0.224 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00765 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T N1 APARTMENT | 2586.32 | 3103.58 | 35.17 | 0.127 | 0.153 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T N2 APARTMENT | 2585.85 | 3103.02 | 35.16 | 0.127 | 0.153 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T S1 APARTMENT | 2772.23 | 3326.67 | 37.70 | 0.137 | 0.164 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00764 | -27.60 | 0.00034 | 0.026 | 0.00 |
| T S2 APARTMENT | 2771.76 | 3326.11 | 37.69 | 0.137 | 0.164 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00764 | -27.60 | 0.00034 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.40 | 0.40 | 0.17 | 0.17 | 0.4041 | 0.4041 | 0.4041 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.37 | 0.37 | 0.16 | 0.16 | 0.3699 | 0.3699 | 0.3699 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.42 | 0.42 | 0.20 | 0.20 | 0.4241 | 0.4241 | 0.4241 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.33 | 0.33 | 0.16 | 0.16 | 0.3261 | 0.3261 | 0.3261 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.29 | 0.29 | 0.11 | 0.11 | 0.2939 | 0.2939 | 0.2939 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.29 | 0.29 | 0.11 | 0.11 | 0.2932 | 0.2932 | 0.2932 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.33 | 0.33 | 0.11 | 0.11 | 0.3313 | 0.3313 | 0.3313 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.33 | 0.33 | 0.12 | 0.12 | 0.3334 | 0.3334 | 0.3334 | 1.0000 | 1.0000 |
| SPLIT MSW | 1.02 | 1.02 | 0.29 | 0.29 | 1.0225 | 1.0225 | 1.0225 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.96 | 0.96 | 0.27 | 0.27 | 0.9640 | 0.9640 | 0.9640 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.88 | 0.88 | 0.29 | 0.29 | 0.8821 | 0.8821 | 0.8821 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.83 | 0.83 | 0.27 | 0.27 | 0.8257 | 0.8257 | 0.8257 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.73 | 0.73 | 0.15 | 0.15 | 0.7337 | 0.7337 | 0.7337 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.73 | 0.73 | 0.15 | 0.15 | 0.7317 | 0.7317 | 0.7317 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.80 | 0.80 | 0.17 | 0.17 | 0.7992 | 0.7992 | 0.7992 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.80 | 0.80 | 0.17 | 0.17 | 0.7970 | 0.7970 | 0.7970 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.57 | 0.57 | 0.24 | 0.24 | 0.5692 | 0.5692 | 0.5692 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.55 | 0.55 | 0.23 | 0.23 | 0.5499 | 0.5499 | 0.5499 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.47 | 0.47 | 0.23 | 0.23 | 0.4673 | 0.4673 | 0.4673 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.45 | 0.45 | 0.22 | 0.22 | 0.4482 | 0.4482 | 0.4482 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.42 | 0.42 | 0.15 | 0.15 | 0.4164 | 0.4164 | 0.4164 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.41 | 0.41 | 0.15 | 0.15 | 0.4135 | 0.4135 | 0.4135 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.44 | 0.44 | 0.16 | 0.16 | 0.4379 | 0.4379 | 0.4379 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.43 | 0.43 | 0.16 | 0.16 | 0.4350 | 0.4350 | 0.4350 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6689.625 | 5356.083 | 0.404120 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6351.01 | 6351.01 | 0.404120 | 25.29 | 14.99 | 0.00793142 | 12.80 | 10.34 | 0.00793142 | 27.16 | 0.00629721 | 14.25 | 6.4225 | 24.00 | 0.00804358 | 37.8967 | 4156.08 | 0.00 | 6688.49 | 5000.61 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 9420.637 | 9420.637 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 9420.64 | 9420.64 | 0.404120 | 17.97 | 11.71 | 0.00722705 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 6.4225 | 21.10 | 0.00769960 | 43.2882 | 2926.74 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 6123.318 | 4902.667 | 0.369910 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5811.13 | 5811.13 | 0.369910 | 25.31 | 14.97 | 0.00790583 | 12.80 | 10.31 | 0.00790583 | 27.16 | 0.00629721 | 14.25 | 7.0165 | 24.00 | 0.00802722 | 37.8202 | 3812.06 | 0.00 | 6122.28 | 4577.29 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 8736.329 | 8736.329 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8736.33 | 8736.33 | 0.369910 | 17.68 | 11.60 | 0.00723031 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 7.0165 | 21.10 | 0.00775011 | 43.5684 | 2785.77 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 7020.215 | 5620.772 | 0.424091 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 12:00:00 | 6732.33 | 6732.33 | 0.424091 | 25.06 | 14.80 | 0.00779732 | 12.80 | 10.21 | 0.00779732 | 24.60 | 0.00629334 | 13.33 | 8.9853 | 23.90 | 0.00796086 | 37.7370 | 4215.76 | 0.00 | 7019.02 | 5247.73 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 10446.333 | 10446.333 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 10446.33 | 10446.33 | 0.424091 | 16.72 | 11.08 | 0.00708032 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 8.9853 | 21.10 | 0.00774556 | 43.5435 | 3457.51 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 5397.540 | 4321.568 | 0.326065 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5121.80 | 5121.80 | 0.326065 | 25.32 | 14.97 | 0.00789226 | 12.80 | 10.30 | 0.00789226 | 27.16 | 0.00629721 | 14.25 | 7.9599 | 24.00 | 0.00803020 | 37.8341 | 3369.39 | 0.00 | 5396.62 | 4034.75 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 7859.381 | 7859.381 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7859.38 | 7859.38 | 0.326065 | 17.22 | 11.35 | 0.00715960 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 7.9599 | 21.10 | 0.00774922 | 43.5634 | 2774.91 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 4865.302 | 3895.430 | 0.293913 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4618.86 | 4618.86 | 0.293913 | 25.34 | 14.99 | 0.00790894 | 12.80 | 10.32 | 0.00790894 | 27.16 | 0.00629721 | 14.25 | 8.8307 | 24.00 | 0.00806505 | 37.9965 | 3045.39 | 0.00 | 4864.47 | 3636.90 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 7216.233 | 7216.233 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7216.23 | 7216.23 | 0.293913 | 16.80 | 11.19 | 0.00715870 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 8.8307 | 21.10 | 0.00781898 | 43.9500 | 1798.44 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 4853.495 | 3885.976 | 0.293200 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4607.65 | 4607.65 | 0.293200 | 25.34 | 14.99 | 0.00790872 | 12.80 | 10.32 | 0.00790872 | 27.16 | 0.00629721 | 14.25 | 8.8522 | 24.00 | 0.00806523 | 37.9973 | 3038.23 | 0.00 | 4852.67 | 3628.07 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 7201.967 | 7201.967 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7201.97 | 7201.97 | 0.293200 | 16.79 | 11.18 | 0.00715707 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 8.8522 | 21.10 | 0.00781895 | 43.9498 | 1798.14 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5484.088 | 4390.864 | 0.331294 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5210.13 | 5210.13 | 0.331294 | 25.32 | 15.02 | 0.00795457 | 12.80 | 10.36 | 0.00795457 | 27.16 | 0.00629721 | 14.25 | 7.8343 | 24.00 | 0.00809545 | 38.1384 | 3422.87 | 0.00 | 5483.15 | 4099.45 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 7963.941 | 7963.941 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7963.94 | 7963.94 | 0.331294 | 17.28 | 11.36 | 0.00714163 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 7.8343 | 21.10 | 0.00771962 | 43.3988 | 1941.26 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5519.277 | 4419.038 | 0.333420 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5243.53 | 5243.53 | 0.333420 | 25.32 | 15.02 | 0.00795481 | 12.80 | 10.36 | 0.00795481 | 27.16 | 0.00629721 | 14.25 | 7.7844 | 24.00 | 0.00809474 | 38.1350 | 3444.25 | 0.00 | 5518.34 | 4125.75 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 8006.460 | 8006.460 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8006.46 | 8006.46 | 0.333420 | 17.31 | 11.37 | 0.00714662 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 7.7844 | 21.10 | 0.00772104 | 43.4067 | 1950.95 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 16925.858 | 13551.777 | 1.022491 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 16063.97 | 16063.97 | 1.022491 | 25.26 | 14.97 | 0.00792648 | 12.80 | 10.34 | 0.00792648 | 27.16 | 0.00629721 | 14.25 | 5.0767 | 24.00 | 0.00801362 | 37.7569 | 20954.05 | 0.00 | 16922.98 | 12652.37 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 23127.523 | 23127.523 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 23127.52 | 23127.52 | 1.022491 | 18.63 | 11.88 | 0.00714052 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.0767 | 21.10 | 0.00750413 | 42.2042 | 9777.34 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 15957.732 | 12776.642 | 0.964007 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 15141.91 | 15141.91 | 0.964007 | 25.27 | 14.96 | 0.00791258 | 12.80 | 10.32 | 0.00791258 | 27.16 | 0.00629721 | 14.25 | 5.3847 | 24.00 | 0.00800451 | 37.7144 | 19772.55 | 0.00 | 15955.02 | 11928.68 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 21957.372 | 21957.372 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21957.37 | 21957.37 | 0.964007 | 18.48 | 11.89 | 0.00721123 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.3847 | 21.10 | 0.00760218 | 42.7481 | 9107.47 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 14601.403 | 11690.690 | 0.882071 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 13857.42 | 13857.42 | 0.882071 | 25.28 | 14.97 | 0.00791740 | 12.80 | 10.33 | 0.00791740 | 27.16 | 0.00629721 | 14.25 | 5.8849 | 24.00 | 0.00801870 | 37.7807 | 18117.26 | 0.00 | 14598.92 | 10914.80 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 20318.769 | 20318.769 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 20318.77 | 20318.77 | 0.882071 | 18.23 | 11.67 | 0.00708032 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.8849 | 21.10 | 0.00750167 | 42.1905 | 9725.84 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 13668.188 | 10943.506 | 0.825695 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12967.48 | 12967.48 | 0.825695 | 25.29 | 14.96 | 0.00789702 | 12.80 | 10.31 | 0.00789702 | 27.16 | 0.00629721 | 14.25 | 6.2867 | 24.00 | 0.00800434 | 37.7136 | 16977.04 | 0.00 | 13665.86 | 10217.21 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 19190.850 | 19190.850 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 19190.85 | 19190.85 | 0.825695 | 18.04 | 11.65 | 0.00714377 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 6.2867 | 21.10 | 0.00760007 | 42.7364 | 9055.97 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 12145.558 | 9724.405 | 0.733713 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11527.90 | 11527.90 | 0.733713 | 25.31 | 14.98 | 0.00791211 | 12.80 | 10.32 | 0.00791211 | 27.16 | 0.00629721 | 14.25 | 7.0748 | 24.00 | 0.00803506 | 37.8568 | 15125.56 | 0.00 | 12143.49 | 9079.01 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 17350.649 | 17350.649 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17350.65 | 17350.65 | 0.733713 | 17.65 | 11.51 | 0.00714404 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 7.0748 | 21.10 | 0.00766192 | 43.0786 | 5037.81 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 12111.575 | 9697.196 | 0.731660 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11495.64 | 11495.64 | 0.731660 | 25.31 | 14.98 | 0.00791186 | 12.80 | 10.32 | 0.00791186 | 27.16 | 0.00629721 | 14.25 | 7.0947 | 24.00 | 0.00803517 | 37.8573 | 15084.35 | 0.00 | 12109.51 | 9053.61 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 17309.587 | 17309.587 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17309.59 | 17309.59 | 0.731660 | 17.64 | 11.50 | 0.00714251 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 7.0947 | 21.10 | 0.00766184 | 43.0782 | 5036.55 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 13230.352 | 10592.951 | 0.799246 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12562.79 | 12562.79 | 0.799246 | 25.29 | 14.99 | 0.00793915 | 12.80 | 10.35 | 0.00793915 | 27.16 | 0.00629721 | 14.25 | 6.4948 | 24.00 | 0.00805320 | 37.9415 | 16444.75 | 0.00 | 13228.10 | 9889.92 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 18661.679 | 18661.679 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18661.68 | 18661.68 | 0.799246 | 17.94 | 11.50 | 0.00702243 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 6.4948 | 21.10 | 0.00748645 | 42.1047 | 5696.68 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 13193.241 | 10563.238 | 0.797004 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12527.58 | 12527.58 | 0.797004 | 25.29 | 14.99 | 0.00793909 | 12.80 | 10.35 | 0.00793909 | 27.16 | 0.00629721 | 14.25 | 6.5130 | 24.00 | 0.00805348 | 37.9428 | 16399.59 | 0.00 | 13191.00 | 9862.17 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 18616.837 | 18616.837 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18616.84 | 18616.84 | 0.797004 | 17.93 | 11.49 | 0.00702102 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 6.5130 | 21.10 | 0.00748634 | 42.1041 | 5695.43 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 9421.457 | 7543.339 | 0.569150 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 8939.61 | 8939.61 | 0.569150 | 25.25 | 14.96 | 0.00791917 | 12.80 | 10.33 | 0.00791917 | 27.16 | 0.00629721 | 14.25 | 4.5602 | 24.00 | 0.00799667 | 37.6779 | 5823.30 | 0.00 | 9419.85 | 7042.70 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 12722.265 | 12722.265 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12722.27 | 12722.27 | 0.569150 | 18.88 | 12.09 | 0.00726288 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 4.5602 | 21.10 | 0.00759358 | 42.7024 | 3992.28 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 9102.644 | 7288.080 | 0.549891 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 8635.69 | 8635.69 | 0.549891 | 25.26 | 14.96 | 0.00790913 | 12.80 | 10.32 | 0.00790913 | 27.16 | 0.00629721 | 14.25 | 4.7199 | 24.00 | 0.00798898 | 37.6420 | 5628.76 | 0.00 | 9101.09 | 6804.38 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 12336.833 | 12336.833 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12336.83 | 12336.83 | 0.549891 | 18.80 | 12.10 | 0.00730974 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 4.7199 | 21.10 | 0.00765491 | 43.0423 | 3807.03 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 7734.648 | 6192.787 | 0.467250 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7338.38 | 7338.38 | 0.467250 | 25.28 | 14.96 | 0.00790327 | 12.80 | 10.31 | 0.00790327 | 27.16 | 0.00629721 | 14.25 | 5.5547 | 24.00 | 0.00799773 | 37.6829 | 4797.48 | 0.00 | 7733.33 | 5781.78 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 10683.961 | 10683.961 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10683.96 | 10683.96 | 0.467250 | 18.39 | 11.83 | 0.00718911 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.5547 | 21.10 | 0.00759183 | 42.6927 | 3974.22 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 7419.158 | 5940.188 | 0.448191 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7037.29 | 7037.29 | 0.448191 | 25.28 | 14.95 | 0.00788813 | 12.80 | 10.30 | 0.00788813 | 27.16 | 0.00629721 | 14.25 | 5.7910 | 24.00 | 0.00798592 | 37.6278 | 4604.76 | 0.00 | 7417.90 | 5545.95 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 10302.579 | 10302.579 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10302.58 | 10302.58 | 0.448191 | 18.28 | 11.83 | 0.00722995 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.7910 | 21.10 | 0.00765336 | 43.0336 | 3788.93 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 6893.205 | 5519.081 | 0.416419 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6541.78 | 6541.78 | 0.416419 | 25.29 | 14.97 | 0.00791111 | 12.80 | 10.32 | 0.00791111 | 27.16 | 0.00629721 | 14.25 | 6.2328 | 24.00 | 0.00801839 | 37.7791 | 4282.89 | 0.00 | 6892.03 | 5152.79 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 9666.757 | 9666.757 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9666.76 | 9666.76 | 0.416419 | 18.06 | 11.79 | 0.00727764 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 6.2328 | 21.10 | 0.00773867 | 43.5056 | 2586.32 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 6845.605 | 5480.970 | 0.413543 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6496.58 | 6496.57 | 0.413543 | 25.29 | 14.97 | 0.00791048 | 12.80 | 10.32 | 0.00791048 | 27.16 | 0.00629721 | 14.25 | 6.2761 | 24.00 | 0.00801851 | 37.7797 | 4253.84 | 0.00 | 6844.44 | 5117.21 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 9609.241 | 9609.241 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9609.24 | 9609.24 | 0.413543 | 18.04 | 11.78 | 0.00727439 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 6.2761 | 21.10 | 0.00773862 | 43.5053 | 2585.85 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 7248.098 | 5803.228 | 0.437858 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6880.59 | 6880.59 | 0.437858 | 25.29 | 14.98 | 0.00792846 | 12.80 | 10.34 | 0.00792846 | 27.16 | 0.00629721 | 14.25 | 5.9276 | 24.00 | 0.00803125 | 37.8391 | 4500.91 | 0.00 | 7246.86 | 5418.08 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 10095.733 | 10095.733 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10095.73 | 10095.73 | 0.437858 | 18.21 | 11.78 | 0.00721152 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.9276 | 21.10 | 0.00764439 | 42.9829 | 2772.23 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 7200.476 | 5765.099 | 0.434981 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6835.38 | 6835.38 | 0.434981 | 25.29 | 14.98 | 0.00792810 | 12.80 | 10.34 | 0.00792810 | 27.16 | 0.00629721 | 14.25 | 5.9668 | 24.00 | 0.00803159 | 37.8407 | 4471.78 | 0.00 | 7199.25 | 5382.48 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 10038.190 | 10038.190 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10038.19 | 10038.19 | 0.434981 | 18.19 | 11.77 | 0.00720861 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 5.9668 | 21.10 | 0.00764433 | 42.9826 | 2771.76 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6689.625 | 5356.083 | 0.404120 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5841 | 1004.8586 | 1.0531 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.404120 | 0.42559512 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6351.01 | 6351.01 | 0.9494 | 0.42559512 | 0.404120 | 25.29 | 14.99 | 0.00793142 | 45622.8 | 12.80 | 10.34 | 0.00793142 | 32886.7 | -999.0 | -999.00 | -999.00 | -999.00 | 452.658 | 5898.35 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 6.4225 | 24.05 | 0.00804358 | 24.00 | 0.00804358 | 37.8967 | 4156.08 | 0.00 | 6688.49 | 5000.61 | 0.40878733 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9420.637 | 9420.637 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.404120 | 0.42559512 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 9420.64 | 9420.64 | 1.0000 | 0.42559512 | 0.404120 | 17.97 | 11.71 | 0.00722705 | 36374.7 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9420.64 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 6.4225 | 21.10 | 0.00769960 | 21.10 | 0.00769960 | 43.2882 | 2926.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6123.318 | 4902.667 | 0.369910 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5365 | 1004.8586 | 1.0531 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.369910 | 0.38956661 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5811.13 | 5811.13 | 0.9490 | 0.38956661 | 0.369910 | 25.31 | 14.97 | 0.00790583 | 45571.5 | 12.80 | 10.31 | 0.00790583 | 32822.1 | -999.0 | -999.00 | -999.00 | -999.00 | 414.339 | 5396.79 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 7.0165 | 24.04 | 0.00802722 | 24.00 | 0.00802722 | 37.8202 | 3812.06 | 0.00 | 6122.28 | 4577.29 | 0.37418167 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8736.329 | 8736.329 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.369910 | 0.38956661 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8736.33 | 8736.33 | 1.0000 | 0.38956661 | 0.369910 | 17.68 | 11.60 | 0.00723031 | 36088.5 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8736.33 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 7.0165 | 21.10 | 0.00775011 | 21.10 | 0.00775011 | 43.5684 | 2785.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7020.215 | 5620.772 | 0.424091 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.3348 | 1004.8586 | 1.0531 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.424091 | 0.44662733 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 12:00:00 | Sensible | 6732.33 | 6732.33 | 0.9590 | 0.44662733 | 0.424091 | 25.06 | 14.80 | 0.00779732 | 45044.6 | 12.80 | 10.21 | 0.00779732 | 32548.1 | -999.0 | -999.00 | -999.00 | -999.00 | 475.028 | 6257.30 | 24.60 | 0.00629334 | 13.33 | 0.03810604 | 8.9853 | 23.96 | 0.00794580 | 23.90 | 0.00796086 | 37.7370 | 4215.76 | 0.00 | 7019.02 | 5247.73 | 0.42898892 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10446.333 | 10446.333 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.424091 | 0.44662733 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 10446.33 | 10446.33 | 1.0000 | 0.44662733 | 0.424091 | 16.72 | 11.08 | 0.00708032 | 34732.2 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10446.33 | -27.60 | 0.00034190 | -27.60 | 0.03810604 | 8.9853 | 21.10 | 0.00774556 | 21.10 | 0.00774556 | 43.5435 | 3457.51 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5397.540 | 4321.568 | 0.326065 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5113 | 1004.8586 | 1.0531 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.326065 | 0.34339244 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5121.80 | 5121.80 | 0.9489 | 0.34339244 | 0.326065 | 25.32 | 14.97 | 0.00789226 | 45556.6 | 12.80 | 10.30 | 0.00789226 | 32787.8 | -999.0 | -999.00 | -999.00 | -999.00 | 365.228 | 4756.57 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 7.9599 | 24.03 | 0.00803020 | 24.00 | 0.00803020 | 37.8341 | 3369.39 | 0.00 | 5396.62 | 4034.75 | 0.32983103 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7859.381 | 7859.381 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.326065 | 0.34339244 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7859.38 | 7859.38 | 1.0000 | 0.34339244 | 0.326065 | 17.22 | 11.35 | 0.00715960 | 35441.5 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7859.38 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 7.9599 | 21.10 | 0.00774922 | 21.10 | 0.00774922 | 43.5634 | 2774.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4865.302 | 3895.430 | 0.293913 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5423 | 1004.8586 | 1.0531 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.293913 | 0.30953139 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4618.86 | 4618.86 | 0.9493 | 0.30953139 | 0.293913 | 25.34 | 14.99 | 0.00790894 | 45616.7 | 12.80 | 10.32 | 0.00790894 | 32829.9 | -999.0 | -999.00 | -999.00 | -999.00 | 329.214 | 4289.65 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 8.8307 | 24.02 | 0.00806505 | 24.00 | 0.00806505 | 37.9965 | 3045.39 | 0.00 | 4864.47 | 3636.90 | 0.29730724 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7216.233 | 7216.233 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.293913 | 0.30953139 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7216.23 | 7216.23 | 1.0000 | 0.30953139 | 0.293913 | 16.80 | 11.19 | 0.00715870 | 35007.7 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7216.23 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 8.8307 | 21.10 | 0.00781898 | 21.10 | 0.00781898 | 43.9500 | 1798.44 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4853.495 | 3885.976 | 0.293200 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5419 | 1004.8586 | 1.0531 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.293200 | 0.30878022 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4607.65 | 4607.65 | 0.9493 | 0.30878022 | 0.293200 | 25.34 | 14.99 | 0.00790872 | 45616.6 | 12.80 | 10.32 | 0.00790872 | 32829.4 | -999.0 | -999.00 | -999.00 | -999.00 | 328.415 | 4279.24 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 8.8522 | 24.02 | 0.00806523 | 24.00 | 0.00806523 | 37.9973 | 3038.23 | 0.00 | 4852.67 | 3628.07 | 0.29658573 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7201.967 | 7201.967 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.293200 | 0.30878022 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7201.97 | 7201.97 | 1.0000 | 0.30878022 | 0.293200 | 16.79 | 11.18 | 0.00715707 | 34992.9 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7201.97 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 8.8522 | 21.10 | 0.00781895 | 21.10 | 0.00781895 | 43.9498 | 1798.14 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5484.088 | 4390.864 | 0.331294 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.6272 | 1004.8586 | 1.0531 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.331294 | 0.34889864 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5210.13 | 5210.13 | 0.9500 | 0.34889864 | 0.331294 | 25.32 | 15.02 | 0.00795457 | 45714.4 | 12.80 | 10.36 | 0.00795457 | 32945.1 | -999.0 | -999.00 | -999.00 | -999.00 | 371.085 | 4839.04 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 7.8343 | 24.04 | 0.00809545 | 24.00 | 0.00809545 | 38.1384 | 3422.87 | 0.00 | 5483.15 | 4099.45 | 0.33511978 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7963.941 | 7963.941 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.331294 | 0.34889864 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7963.94 | 7963.94 | 1.0000 | 0.34889864 | 0.331294 | 17.28 | 11.36 | 0.00714163 | 35458.3 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7963.94 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 7.8343 | 21.10 | 0.00771962 | 21.10 | 0.00771962 | 43.3988 | 1941.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5519.277 | 4419.038 | 0.333420 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.6276 | 1004.8586 | 1.0531 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.333420 | 0.35113741 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5243.53 | 5243.53 | 0.9500 | 0.35113741 | 0.333420 | 25.32 | 15.02 | 0.00795481 | 45713.6 | 12.80 | 10.36 | 0.00795481 | 32945.7 | -999.0 | -999.00 | -999.00 | -999.00 | 373.466 | 4870.06 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 7.7844 | 24.04 | 0.00809474 | 24.00 | 0.00809474 | 38.1350 | 3444.25 | 0.00 | 5518.34 | 4125.75 | 0.33727013 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8006.460 | 8006.460 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.333420 | 0.35113741 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8006.46 | 8006.46 | 1.0000 | 0.35113741 | 0.333420 | 17.31 | 11.37 | 0.00714662 | 35495.7 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8006.46 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 7.7844 | 21.10 | 0.00772104 | 21.10 | 0.00772104 | 43.4067 | 1950.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 16925.858 | 13551.777 | 1.022491 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5749 | 1004.8586 | 1.0531 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 1.022491 | 1.07682611 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 16063.97 | 16063.97 | 0.9491 | 1.07682611 | 1.022491 | 25.26 | 14.97 | 0.00792648 | 45581.3 | 12.80 | 10.34 | 0.00792648 | 32874.2 | -999.0 | -999.00 | -999.00 | -999.00 | 1145.300 | 14918.67 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 5.0767 | 24.06 | 0.00801362 | 24.00 | 0.00801362 | 37.7569 | 20954.05 | 0.00 | 16922.98 | 12652.37 | 1.03429962 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 23127.523 | 23127.523 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 1.022491 | 1.07682611 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 23127.52 | 23127.52 | 1.0000 | 1.07682611 | 1.022491 | 18.63 | 11.88 | 0.00714052 | 36821.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23127.52 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 5.0767 | 21.10 | 0.00750413 | 21.10 | 0.00750413 | 42.2042 | 9777.34 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 15957.732 | 12776.642 | 0.964007 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5491 | 1004.8586 | 1.0531 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.964007 | 1.01523380 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 15141.91 | 15141.91 | 0.9489 | 1.01523380 | 0.964007 | 25.27 | 14.96 | 0.00791258 | 45553.0 | 12.80 | 10.32 | 0.00791258 | 32839.1 | -999.0 | -999.00 | -999.00 | -999.00 | 1079.791 | 14062.12 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 5.3847 | 24.06 | 0.00800451 | 24.00 | 0.00800451 | 37.7144 | 19772.55 | 0.00 | 15955.02 | 11928.68 | 0.97513974 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21957.372 | 21957.372 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.964007 | 1.01523380 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 21957.37 | 21957.37 | 1.0000 | 1.01523380 | 0.964007 | 18.48 | 11.89 | 0.00721123 | 36848.6 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21957.37 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 5.3847 | 21.10 | 0.00760218 | 21.10 | 0.00760218 | 42.7481 | 9107.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14601.403 | 11690.690 | 0.882071 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5580 | 1004.8586 | 1.0531 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.882071 | 0.92894386 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 13857.42 | 13857.42 | 0.9490 | 0.92894386 | 0.882071 | 25.28 | 14.97 | 0.00791740 | 45576.5 | 12.80 | 10.33 | 0.00791740 | 32851.3 | -999.0 | -999.00 | -999.00 | -999.00 | 988.014 | 12869.41 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 5.8849 | 24.06 | 0.00801870 | 24.00 | 0.00801870 | 37.7807 | 18117.26 | 0.00 | 14598.92 | 10914.80 | 0.89225760 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20318.769 | 20318.769 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.882071 | 0.92894386 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 20318.77 | 20318.77 | 1.0000 | 0.92894386 | 0.882071 | 18.23 | 11.67 | 0.00708032 | 36268.5 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20318.77 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 5.8849 | 21.10 | 0.00750167 | 21.10 | 0.00750167 | 42.1905 | 9725.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13668.188 | 10943.506 | 0.825695 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5202 | 1004.8586 | 1.0531 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.825695 | 0.86957256 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12967.48 | 12967.48 | 0.9487 | 0.86957256 | 0.825695 | 25.29 | 14.96 | 0.00789702 | 45532.7 | 12.80 | 10.31 | 0.00789702 | 32799.8 | -999.0 | -999.00 | -999.00 | -999.00 | 924.868 | 12042.62 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 6.2867 | 24.05 | 0.00800434 | 24.00 | 0.00800434 | 37.7136 | 16977.04 | 0.00 | 13665.86 | 10217.21 | 0.83523102 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 19190.850 | 19190.850 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.825695 | 0.86957256 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 19190.85 | 19190.85 | 1.0000 | 0.86957256 | 0.825695 | 18.04 | 11.65 | 0.00714377 | 36230.4 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19190.85 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 6.2867 | 21.10 | 0.00760007 | 21.10 | 0.00760007 | 42.7364 | 9055.97 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12145.558 | 9724.405 | 0.733713 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5482 | 1004.8586 | 1.0531 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.733713 | 0.77270261 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11527.90 | 11527.90 | 0.9491 | 0.77270261 | 0.733713 | 25.31 | 14.98 | 0.00791211 | 45589.5 | 12.80 | 10.32 | 0.00791211 | 32837.9 | -999.0 | -999.00 | -999.00 | -999.00 | 821.838 | 10706.06 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 7.0748 | 24.04 | 0.00803506 | 24.00 | 0.00803506 | 37.8568 | 15125.56 | 0.00 | 12143.49 | 9079.01 | 0.74218670 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17350.649 | 17350.649 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.733713 | 0.77270261 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17350.65 | 17350.65 | 1.0000 | 0.77270261 | 0.733713 | 17.65 | 11.51 | 0.00714404 | 35840.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17350.65 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 7.0748 | 21.10 | 0.00766192 | 21.10 | 0.00766192 | 43.0786 | 5037.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12111.575 | 9697.196 | 0.731660 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5478 | 1004.8586 | 1.0531 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.731660 | 0.77054057 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11495.64 | 11495.64 | 0.9491 | 0.77054057 | 0.731660 | 25.31 | 14.98 | 0.00791186 | 45589.3 | 12.80 | 10.32 | 0.00791186 | 32837.3 | -999.0 | -999.00 | -999.00 | -999.00 | 819.538 | 10676.10 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 7.0947 | 24.04 | 0.00803517 | 24.00 | 0.00803517 | 37.8573 | 15084.35 | 0.00 | 12109.51 | 9053.61 | 0.74011004 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17309.587 | 17309.587 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.731660 | 0.77054057 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17309.59 | 17309.59 | 1.0000 | 0.77054057 | 0.731660 | 17.64 | 11.50 | 0.00714251 | 35827.1 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17309.59 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 7.0947 | 21.10 | 0.00766184 | 21.10 | 0.00766184 | 43.0782 | 5036.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13230.352 | 10592.951 | 0.799246 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5985 | 1004.8586 | 1.0531 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.799246 | 0.84171737 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12562.79 | 12562.79 | 0.9495 | 0.84171737 | 0.799246 | 25.29 | 14.99 | 0.00793915 | 45645.3 | 12.80 | 10.35 | 0.00793915 | 32906.2 | -999.0 | -999.00 | -999.00 | -999.00 | 895.241 | 11667.55 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 6.4948 | 24.05 | 0.00805320 | 24.00 | 0.00805320 | 37.9415 | 16444.75 | 0.00 | 13228.10 | 9889.92 | 0.80847590 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18661.679 | 18661.679 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.799246 | 0.84171737 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18661.68 | 18661.68 | 1.0000 | 0.84171737 | 0.799246 | 17.94 | 11.50 | 0.00702243 | 35819.9 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18661.68 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 6.4948 | 21.10 | 0.00748645 | 21.10 | 0.00748645 | 42.1047 | 5696.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13193.241 | 10563.238 | 0.797004 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5984 | 1004.8586 | 1.0531 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.797004 | 0.83935638 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12527.58 | 12527.58 | 0.9495 | 0.83935638 | 0.797004 | 25.29 | 14.99 | 0.00793909 | 45645.6 | 12.80 | 10.35 | 0.00793909 | 32906.1 | -999.0 | -999.00 | -999.00 | -999.00 | 892.730 | 11634.85 | 27.16 | 0.00629721 | 14.25 | 0.05190911 | 6.5130 | 24.05 | 0.00805348 | 24.00 | 0.00805348 | 37.9428 | 16399.59 | 0.00 | 13191.00 | 9862.17 | 0.80620815 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18616.837 | 18616.837 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.797004 | 0.83935638 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18616.84 | 18616.84 | 1.0000 | 0.83935638 | 0.797004 | 17.93 | 11.49 | 0.00702102 | 35807.2 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18616.84 | -27.60 | 0.00034190 | -27.60 | 0.05190911 | 6.5130 | 21.10 | 0.00748634 | 21.10 | 0.00748634 | 42.1041 | 5695.43 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9421.457 | 7543.339 | 0.569150 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5613 | 1004.8586 | 1.0531 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.569150 | 0.59939478 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 8939.61 | 8939.61 | 0.9489 | 0.59939478 | 0.569150 | 25.25 | 14.96 | 0.00791917 | 45550.7 | 12.80 | 10.33 | 0.00791917 | 32855.7 | -999.0 | -999.00 | -999.00 | -999.00 | 637.510 | 8302.10 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 4.5602 | 24.07 | 0.00799667 | 24.00 | 0.00799667 | 37.6779 | 5823.30 | 0.00 | 9419.85 | 7042.70 | 0.57572322 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12722.265 | 12722.265 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.569150 | 0.59939478 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12722.27 | 12722.27 | 1.0000 | 0.59939478 | 0.569150 | 18.88 | 12.09 | 0.00726288 | 37387.7 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12722.27 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 4.5602 | 21.10 | 0.00759358 | 21.10 | 0.00759358 | 42.7024 | 3992.28 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9102.644 | 7288.080 | 0.549891 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5427 | 1004.8586 | 1.0531 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.549891 | 0.57911183 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 8635.69 | 8635.69 | 0.9487 | 0.57911183 | 0.549891 | 25.26 | 14.96 | 0.00790913 | 45529.0 | 12.80 | 10.32 | 0.00790913 | 32830.4 | -999.0 | -999.00 | -999.00 | -999.00 | 615.937 | 8019.75 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 4.7199 | 24.07 | 0.00798898 | 24.00 | 0.00798898 | 37.6420 | 5628.76 | 0.00 | 9101.09 | 6804.38 | 0.55624129 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12336.833 | 12336.833 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.549891 | 0.57911183 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12336.83 | 12336.83 | 1.0000 | 0.57911183 | 0.549891 | 18.80 | 12.10 | 0.00730974 | 37427.7 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12336.83 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 4.7199 | 21.10 | 0.00765491 | 21.10 | 0.00765491 | 43.0423 | 3807.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7734.648 | 6192.787 | 0.467250 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5318 | 1004.8586 | 1.0531 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.467250 | 0.49207973 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7338.38 | 7338.38 | 0.9488 | 0.49207973 | 0.467250 | 25.28 | 14.96 | 0.00790327 | 45537.4 | 12.80 | 10.31 | 0.00790327 | 32815.6 | -999.0 | -999.00 | -999.00 | -999.00 | 523.371 | 6815.01 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 5.5547 | 24.06 | 0.00799773 | 24.00 | 0.00799773 | 37.6829 | 4797.48 | 0.00 | 7733.33 | 5781.78 | 0.47264630 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10683.961 | 10683.961 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.467250 | 0.49207973 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10683.96 | 10683.96 | 1.0000 | 0.49207973 | 0.467250 | 18.39 | 11.83 | 0.00718911 | 36707.5 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10683.96 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 5.5547 | 21.10 | 0.00759183 | 21.10 | 0.00759183 | 42.6927 | 3974.22 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7419.158 | 5940.188 | 0.448191 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5036 | 1004.8586 | 1.0531 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.448191 | 0.47200816 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7037.29 | 7037.29 | 0.9485 | 0.47200816 | 0.448191 | 25.28 | 14.95 | 0.00788813 | 45504.4 | 12.80 | 10.30 | 0.00788813 | 32777.4 | -999.0 | -999.00 | -999.00 | -999.00 | 502.023 | 6535.27 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 5.7910 | 24.06 | 0.00798592 | 24.00 | 0.00798592 | 37.6278 | 4604.76 | 0.00 | 7417.90 | 5545.95 | 0.45336740 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10302.579 | 10302.579 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.448191 | 0.47200816 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10302.58 | 10302.58 | 1.0000 | 0.47200816 | 0.448191 | 18.28 | 11.83 | 0.00722995 | 36694.2 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10302.58 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 5.7910 | 21.10 | 0.00765336 | 21.10 | 0.00765336 | 43.0336 | 3788.93 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6893.205 | 5519.081 | 0.416419 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5464 | 1004.8586 | 1.0531 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.416419 | 0.43854695 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6541.78 | 6541.78 | 0.9490 | 0.43854695 | 0.416419 | 25.29 | 14.97 | 0.00791111 | 45572.1 | 12.80 | 10.32 | 0.00791111 | 32835.4 | -999.0 | -999.00 | -999.00 | -999.00 | 466.434 | 6075.34 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 6.2328 | 24.06 | 0.00801839 | 24.00 | 0.00801839 | 37.7791 | 4282.89 | 0.00 | 6892.03 | 5152.79 | 0.42122766 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9666.757 | 9666.757 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.416419 | 0.43854695 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9666.76 | 9666.76 | 1.0000 | 0.43854695 | 0.416419 | 18.06 | 11.79 | 0.00727764 | 36596.6 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9666.76 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 6.2328 | 21.10 | 0.00773867 | 21.10 | 0.00773867 | 43.5056 | 2586.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6845.605 | 5480.970 | 0.413543 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5452 | 1004.8586 | 1.0531 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.413543 | 0.43551861 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6496.58 | 6496.57 | 0.9490 | 0.43551861 | 0.413543 | 25.29 | 14.97 | 0.00791048 | 45571.5 | 12.80 | 10.32 | 0.00791048 | 32833.8 | -999.0 | -999.00 | -999.00 | -999.00 | 463.213 | 6033.36 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 6.2761 | 24.06 | 0.00801851 | 24.00 | 0.00801851 | 37.7797 | 4253.84 | 0.00 | 6844.44 | 5117.21 | 0.41831892 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9609.241 | 9609.241 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.413543 | 0.43551861 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9609.24 | 9609.24 | 1.0000 | 0.43551861 | 0.413543 | 18.04 | 11.78 | 0.00727439 | 36566.9 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9609.24 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 6.2761 | 21.10 | 0.00773862 | 21.10 | 0.00773862 | 43.5053 | 2585.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7248.098 | 5803.228 | 0.437858 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5786 | 1004.8586 | 1.0531 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.437858 | 0.46112531 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6880.59 | 6880.59 | 0.9493 | 0.46112531 | 0.437858 | 25.29 | 14.98 | 0.00792846 | 45610.9 | 12.80 | 10.34 | 0.00792846 | 32879.2 | -999.0 | -999.00 | -999.00 | -999.00 | 490.448 | 6390.14 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 5.9276 | 24.06 | 0.00803125 | 24.00 | 0.00803125 | 37.8391 | 4500.91 | 0.00 | 7246.86 | 5418.08 | 0.44291434 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10095.733 | 10095.733 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.437858 | 0.46112531 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10095.73 | 10095.73 | 1.0000 | 0.46112531 | 0.437858 | 18.21 | 11.78 | 0.00721152 | 36580.1 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10095.73 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 5.9276 | 21.10 | 0.00764439 | 21.10 | 0.00764439 | 42.9829 | 2772.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7200.476 | 5765.099 | 0.434981 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.5779 | 1004.8586 | 1.0531 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.434981 | 0.45809560 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6835.38 | 6835.38 | 0.9493 | 0.45809560 | 0.434981 | 25.29 | 14.98 | 0.00792810 | 45610.9 | 12.80 | 10.34 | 0.00792810 | 32878.3 | -999.0 | -999.00 | -999.00 | -999.00 | 487.225 | 6348.15 | 27.16 | 0.00629721 | 14.25 | 0.02595455 | 5.9668 | 24.06 | 0.00803159 | 24.00 | 0.00803159 | 37.8407 | 4471.78 | 0.00 | 7199.25 | 5382.48 | 0.44000429 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 13.89 | 0.00956578 | 38960.6 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10038.190 | 10038.190 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.434981 | 0.45809560 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10038.19 | 10038.19 | 1.0000 | 0.45809560 | 0.434981 | 18.19 | 11.77 | 0.00720861 | 36553.2 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10038.19 | -27.60 | 0.00034190 | -27.60 | 0.02595455 | 5.9668 | 21.10 | 0.00764433 | 21.10 | 0.00764433 | 42.9826 | 2771.76 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 2857.50 | 4857.67 | 2577.17 |
| G NW APARTMENT | 4651.00 | 7356.50 | 4450.50 |
| OFFICE | 1117.50 | 1166.50 | 693.33 |
| G NE APARTMENT | 4688.00 | 7270.33 | 4439.67 |
| G N1 APARTMENT | 4279.50 | 7353.67 | 4150.00 |
| G N2 APARTMENT | 4277.83 | 7346.50 | 4147.83 |
| G S1 APARTMENT | 2271.17 | 4757.33 | 2060.17 |
| G S2 APARTMENT | 2469.33 | 4682.83 | 2196.00 |
| M SW APARTMENT | 1954.33 | 4421.83 | 1548.67 |
| M NW APARTMENT | 3569.00 | 6619.50 | 3225.83 |
| M SE APARTMENT | 1953.50 | 4444.83 | 1562.17 |
| M NE APARTMENT | 3587.83 | 6571.17 | 3207.67 |
| M N1 APARTMENT | 2773.17 | 6641.17 | 2589.83 |
| M N2 APARTMENT | 2773.50 | 6637.33 | 2589.33 |
| M S1 APARTMENT | 1271.50 | 4366.83 | 1015.67 |
| M S2 APARTMENT | 1273.00 | 4365.67 | 1014.67 |
| T SW APARTMENT | 3211.17 | 4859.83 | 2683.00 |
| T NW APARTMENT | 5041.83 | 7087.17 | 4348.83 |
| T SE APARTMENT | 3187.83 | 4885.83 | 2696.50 |
| T NE APARTMENT | 5061.17 | 7020.00 | 4314.17 |
| T N1 APARTMENT | 4521.33 | 7103.33 | 4103.00 |
| T N2 APARTMENT | 4526.33 | 7095.00 | 4102.50 |
| T S1 APARTMENT | 2719.67 | 4836.00 | 2317.50 |
| T S2 APARTMENT | 2720.50 | 4835.33 | 2319.17 |
| T CORRIDOR | 6112.17 | 8500.33 | 5943.83 |
| G CORRIDOR | 6192.50 | 6920.33 | 4744.50 |
| M CORRIDOR | 5862.00 | 8690.00 | 5833.50 |
| Facility | 8701.17 | 8760.00 | 8668.33 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.351 | 0.125 | 0.000 | 0.040 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.133 | 0.000 | 0.055 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.517 | 0.149 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.133 | 0.000 | 0.055 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.080 | 0.000 | 0.055 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.080 | 0.000 | 0.055 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.076 | 0.000 | 0.040 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.076 | 0.000 | 0.040 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.180 | 0.000 | 0.050 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.191 | 0.000 | 0.071 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.180 | 0.000 | 0.050 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.191 | 0.000 | 0.071 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.115 | 0.000 | 0.071 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.115 | 0.000 | 0.071 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.109 | 0.000 | 0.050 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.109 | 0.000 | 0.050 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.351 | 0.238 | 0.000 | 0.060 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.252 | 0.000 | 0.085 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.351 | 0.238 | 0.000 | 0.060 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.252 | 0.000 | 0.086 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.152 | 0.000 | 0.085 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.152 | 0.000 | 0.085 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.143 | 0.000 | 0.060 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.143 | 0.000 | 0.060 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.498 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.21 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 128212.47 | 946715.25 | 308830.59 | 1255545.84 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 2615.00 |
| G NW APARTMENT | 818502.78 | 126670.14 | 945172.92 | 308830.59 | 1254003.51 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 308830.59 | 1510542.56 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 127017.92 | 945520.69 | 308830.59 | 1254351.28 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 0.00 |
| G N1 APARTMENT | 818502.78 | 126890.82 | 945393.59 | 186278.77 | 1131672.36 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 0.00 |
| G N2 APARTMENT | 818502.78 | 126913.46 | 945416.24 | 186278.77 | 1131695.01 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 0.00 |
| G S1 APARTMENT | 818502.78 | 128620.72 | 947123.50 | 186278.77 | 1133402.27 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 128716.37 | 947219.15 | 186278.77 | 1133497.92 | 818502.78 | 0.00 | 7630.33 | 1129.67 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 163463.72 | 1800469.28 | 443814.04 | 2244283.32 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 163716.43 | 1800721.99 | 443814.04 | 2244536.03 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 0.00 |
| M SE APARTMENT | 1637005.55 | 163567.57 | 1800573.12 | 443814.04 | 2244387.16 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 163963.40 | 1800968.95 | 443814.04 | 2244782.99 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 163711.29 | 1800716.84 | 267697.36 | 2068414.20 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 163734.87 | 1800740.42 | 267697.36 | 2068437.79 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 163555.25 | 1800560.80 | 267697.36 | 2068258.17 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 163560.19 | 1800565.75 | 267697.36 | 2068263.11 | 1637005.55 | 0.00 | 7615.17 | 1144.83 | 2615.00 |
| T SW APARTMENT | 818502.78 | 196382.11 | 1014884.89 | 587076.63 | 1601961.51 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 2615.00 |
| T NW APARTMENT | 818502.78 | 197445.52 | 1015948.29 | 587076.63 | 1603024.92 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 0.00 |
| T SE APARTMENT | 818502.78 | 196894.35 | 1015397.13 | 587076.63 | 1602473.76 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 2615.00 |
| T NE APARTMENT | 818502.78 | 198150.43 | 1016653.20 | 587076.63 | 1603729.83 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 0.00 |
| T N1 APARTMENT | 818502.78 | 197594.54 | 1016097.32 | 354109.72 | 1370207.03 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 0.00 |
| T N2 APARTMENT | 818502.78 | 197659.92 | 1016162.70 | 354109.72 | 1370272.41 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 0.00 |
| T S1 APARTMENT | 818502.78 | 196693.35 | 1015196.13 | 354109.72 | 1369305.85 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 196723.61 | 1015226.39 | 354109.72 | 1369336.10 | 818502.78 | 0.00 | 7636.17 | 1123.83 | 2615.00 |
| Total Facility | 39671342.50 | 5089131.16 | 44760473.66 | 11437274.04 | 56197747.70 | 39671342.50 | 0.00 | 8760.00 | 1148.33 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0029 | 0.0289 | 0.0092 | 0.0381 | 0.0260 | 0.00 | 5550.00 | 595.00 |
| G NW APARTMENT | 0.0260 | 0.0040 | 0.0300 | 0.0098 | 0.0398 | 0.0260 | 0.00 | 7630.33 | 1129.67 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0109 | 0.0491 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0040 | 0.0300 | 0.0098 | 0.0398 | 0.0260 | 0.00 | 7630.33 | 1129.67 |
| G N1 APARTMENT | 0.0260 | 0.0040 | 0.0300 | 0.0059 | 0.0359 | 0.0260 | 0.00 | 7630.33 | 1129.67 |
| G N2 APARTMENT | 0.0260 | 0.0040 | 0.0300 | 0.0059 | 0.0359 | 0.0260 | 0.00 | 7630.33 | 1129.67 |
| G S1 APARTMENT | 0.0260 | 0.0029 | 0.0289 | 0.0056 | 0.0344 | 0.0260 | 0.00 | 5550.00 | 595.00 |
| G S2 APARTMENT | 0.0260 | 0.0029 | 0.0289 | 0.0056 | 0.0345 | 0.0260 | 0.00 | 5550.00 | 595.00 |
| M SW APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0133 | 0.0689 | 0.0519 | 0.00 | 5541.17 | 603.83 |
| M NW APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0141 | 0.0712 | 0.0519 | 0.00 | 7615.17 | 1144.83 |
| M SE APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0133 | 0.0689 | 0.0519 | 0.00 | 5541.17 | 603.83 |
| M NE APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0141 | 0.0712 | 0.0519 | 0.00 | 7615.17 | 1144.83 |
| M N1 APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0085 | 0.0656 | 0.0519 | 0.00 | 7615.17 | 1144.83 |
| M N2 APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0085 | 0.0656 | 0.0519 | 0.00 | 7615.17 | 1144.83 |
| M S1 APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0080 | 0.0636 | 0.0519 | 0.00 | 5541.17 | 603.83 |
| M S2 APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0080 | 0.0636 | 0.0519 | 0.00 | 5541.17 | 603.83 |
| T SW APARTMENT | 0.0260 | 0.0044 | 0.0303 | 0.0176 | 0.0479 | 0.0260 | 0.00 | 5551.83 | 593.17 |
| T NW APARTMENT | 0.0260 | 0.0063 | 0.0322 | 0.0186 | 0.0508 | 0.0260 | 0.00 | 7636.17 | 1123.83 |
| T SE APARTMENT | 0.0260 | 0.0044 | 0.0303 | 0.0176 | 0.0479 | 0.0260 | 0.00 | 5551.83 | 593.17 |
| T NE APARTMENT | 0.0260 | 0.0063 | 0.0322 | 0.0186 | 0.0509 | 0.0260 | 0.00 | 7636.17 | 1123.83 |
| T N1 APARTMENT | 0.0260 | 0.0063 | 0.0322 | 0.0112 | 0.0434 | 0.0260 | 0.00 | 7636.17 | 1123.83 |
| T N2 APARTMENT | 0.0260 | 0.0063 | 0.0322 | 0.0112 | 0.0435 | 0.0260 | 0.00 | 7636.17 | 1123.83 |
| T S1 APARTMENT | 0.0260 | 0.0044 | 0.0303 | 0.0106 | 0.0409 | 0.0260 | 0.00 | 5551.83 | 593.17 |
| T S2 APARTMENT | 0.0260 | 0.0044 | 0.0303 | 0.0106 | 0.0409 | 0.0260 | 0.00 | 5551.83 | 593.17 |
| Total Facility | 1.2580 | 0.1384 | 1.3964 | 0.3541 | 1.7505 | 1.2580 | 0.00 | 8760.00 | 1148.33 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 128212.47 | 128212.47 | 818502.78 | 7989.25 | 28.97 | 741.78 | 534.67 |
| SPLIT GNW | 0.00 | 126670.14 | 126670.14 | 818502.78 | 8008.33 | 27.00 | 724.67 | 0.00 |
| SPLIT OFFICE | 1332823.08 | 0.00 | 1332823.08 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 127017.92 | 127017.92 | 818502.78 | 8003.83 | 27.33 | 728.83 | 0.00 |
| SPLIT GN1 | 0.00 | 126890.82 | 126890.82 | 818502.78 | 8007.83 | 26.83 | 725.33 | 0.00 |
| SPLIT GN2 | 0.00 | 126913.46 | 126913.46 | 818502.78 | 8007.83 | 26.50 | 725.67 | 0.00 |
| SPLIT GS1 | 0.00 | 128620.72 | 128620.72 | 818502.78 | 7988.00 | 27.67 | 744.33 | 534.67 |
| SPLIT GS2 | 0.00 | 128716.37 | 128716.37 | 818502.78 | 7986.17 | 27.67 | 746.17 | 534.67 |
| SPLIT MSW | 0.00 | 163463.72 | 163463.72 | 1637005.55 | 8512.75 | 13.92 | 233.33 | 541.00 |
| SPLIT MNW | 0.00 | 163716.43 | 163716.43 | 1637005.55 | 8515.83 | 13.67 | 230.50 | 0.00 |
| SPLIT MSE | 0.00 | 163567.57 | 163567.57 | 1637005.55 | 8512.17 | 13.83 | 234.00 | 541.00 |
| SPLIT MNE | 0.00 | 163963.40 | 163963.40 | 1637005.55 | 8513.17 | 15.50 | 231.33 | 0.00 |
| SPLIT MN1 | 0.00 | 163711.29 | 163711.29 | 1637005.55 | 8515.08 | 14.58 | 230.33 | 0.00 |
| SPLIT MN2 | 0.00 | 163734.87 | 163734.87 | 1637005.55 | 8514.92 | 14.42 | 230.67 | 0.00 |
| SPLIT MS1 | 0.00 | 163555.25 | 163555.25 | 1637005.55 | 8512.17 | 13.67 | 234.17 | 541.00 |
| SPLIT MS2 | 0.00 | 163560.19 | 163560.19 | 1637005.55 | 8512.17 | 13.50 | 234.33 | 541.00 |
| SPLIT TSW | 0.00 | 196382.11 | 196382.11 | 818502.78 | 7764.50 | 9.83 | 985.67 | 530.67 |
| SPLIT TNW | 0.00 | 197445.52 | 197445.52 | 818502.78 | 7758.67 | 9.33 | 992.00 | 0.00 |
| SPLIT TSE | 0.00 | 196894.35 | 196894.35 | 818502.78 | 7763.83 | 9.83 | 986.33 | 530.67 |
| SPLIT TNE | 0.00 | 198150.43 | 198150.43 | 818502.78 | 7757.83 | 9.83 | 992.33 | 0.00 |
| SPLIT TN1 | 0.00 | 197594.54 | 197594.54 | 818502.78 | 7758.00 | 10.33 | 991.67 | 0.00 |
| SPLIT TN2 | 0.00 | 197659.92 | 197659.92 | 818502.78 | 7758.00 | 10.00 | 992.00 | 0.00 |
| SPLIT TS1 | 0.00 | 196693.35 | 196693.35 | 818502.78 | 7763.83 | 9.83 | 986.33 | 530.67 |
| SPLIT TS2 | 0.00 | 196723.61 | 196723.61 | 818502.78 | 7763.83 | 9.83 | 986.33 | 530.67 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0029 | 0.0029 | 0.0260 | 5755.42 | 16.14 | 373.44 |
| SPLIT GNW | 0.0000 | 0.0040 | 0.0040 | 0.0260 | 8008.33 | 27.00 | 724.67 |
| SPLIT OFFICE | 0.0423 | 0.0000 | 0.0423 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0040 | 0.0040 | 0.0260 | 8003.83 | 27.33 | 728.83 |
| SPLIT GN1 | 0.0000 | 0.0040 | 0.0040 | 0.0260 | 8007.83 | 26.83 | 725.33 |
| SPLIT GN2 | 0.0000 | 0.0040 | 0.0040 | 0.0260 | 8007.83 | 26.50 | 725.67 |
| SPLIT GS1 | 0.0000 | 0.0029 | 0.0029 | 0.0260 | 5754.83 | 15.83 | 374.33 |
| SPLIT GS2 | 0.0000 | 0.0029 | 0.0029 | 0.0260 | 5753.83 | 15.83 | 375.33 |
| SPLIT MSW | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 6045.25 | 7.25 | 92.50 |
| SPLIT MNW | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 8515.83 | 13.67 | 230.50 |
| SPLIT MSE | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 6044.67 | 7.17 | 93.17 |
| SPLIT MNE | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 8513.17 | 15.50 | 231.33 |
| SPLIT MN1 | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 8515.08 | 14.58 | 230.33 |
| SPLIT MN2 | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 8514.92 | 14.42 | 230.67 |
| SPLIT MS1 | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 6044.83 | 7.00 | 93.17 |
| SPLIT MS2 | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 6044.83 | 6.83 | 93.33 |
| SPLIT TSW | 0.0000 | 0.0044 | 0.0044 | 0.0260 | 5623.33 | 5.83 | 515.83 |
| SPLIT TNW | 0.0000 | 0.0063 | 0.0063 | 0.0260 | 7758.67 | 9.33 | 992.00 |
| SPLIT TSE | 0.0000 | 0.0044 | 0.0044 | 0.0260 | 5622.83 | 5.83 | 516.33 |
| SPLIT TNE | 0.0000 | 0.0063 | 0.0063 | 0.0260 | 7757.83 | 9.83 | 992.33 |
| SPLIT TN1 | 0.0000 | 0.0063 | 0.0063 | 0.0260 | 7758.00 | 10.33 | 991.67 |
| SPLIT TN2 | 0.0000 | 0.0063 | 0.0063 | 0.0260 | 7758.00 | 10.00 | 992.00 |
| SPLIT TS1 | 0.0000 | 0.0044 | 0.0044 | 0.0260 | 5622.83 | 5.83 | 516.33 |
| SPLIT TS2 | 0.0000 | 0.0044 | 0.0044 | 0.0260 | 5622.83 | 5.83 | 516.33 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0423 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 96.57 | 1715.46 | 07-APR-10:20 | 9196.14 | 17-JUL-16:10 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| ElectricityPurchased:Plant | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| Cogeneration:ElectricityPurchased | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| General:Cogeneration:ElectricityPurchased | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| ElectricityNet:Plant | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| Cogeneration:ElectricityNet | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| General:Cogeneration:ElectricityNet | 1268.14 | 16924.24 | 29-JUN-04:50 | 87470.23 | 17-JUL-17:40 |
| Electricity:HVAC | 164.64 | 1715.46 | 07-APR-20:50 | 36107.74 | 17-JUL-16:00 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 96.57 | 1715.46 | 07-APR-10:20 | 9196.14 | 17-JUL-16:10 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 68.07 | 0.00 | 01-JAN-00:10 | 27058.21 | 17-JUL-16:00 |
| General:Cooling:Electricity | 68.07 | 0.00 | 01-JAN-00:10 | 27058.21 | 17-JUL-16:00 |
| ExteriorLights:Electricity | 49.94 | 0.00 | 01-JAN-08:20 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 49.94 | 0.00 | 01-JAN-08:20 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 495.68 | 1950.00 | 01-JAN-00:10 | 40913.84 | 11-JAN-07:30 |
| WaterSystems:Electricity | 495.68 | 1950.00 | 01-JAN-00:10 | 40913.84 | 11-JAN-07:30 |
| Water Heater:WaterSystems:Electricity | 495.68 | 1950.00 | 01-JAN-00:10 | 40913.84 | 11-JAN-07:30 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 586.17 | 0.00 | 27-FEB-14:10 | 141409.12 | 10-JAN-23:10 |
| NaturalGas:HVAC | 586.17 | 0.00 | 27-FEB-14:10 | 141409.12 | 10-JAN-23:10 |
| Heating:NaturalGas | 586.17 | 0.00 | 27-FEB-14:10 | 141409.12 | 10-JAN-23:10 |
| General:Heating:NaturalGas | 586.17 | 0.00 | 27-FEB-14:10 | 141409.12 | 10-JAN-23:10 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 1326.79 | 2981.46 | 07-APR-10:50 | 184137.05 | 10-JAN-23:10 |
| EnergyTransfer:Building | 601.19 | 2835.88 | 07-APR-10:50 | 75104.94 | 11-JAN-08:10 |
| EnergyTransfer:Zone:G SW APARTMENT | 17.92 | 0.02 | 16-JAN-14:40 | 2753.53 | 11-JAN-08:20 |
| Heating:EnergyTransfer | 232.41 | 0.00 | 27-FEB-14:00 | 75104.94 | 11-JAN-08:10 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 8.05 | 0.00 | 01-JAN-10:30 | 2753.53 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer | 232.41 | 0.00 | 27-FEB-14:00 | 75104.94 | 11-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 8.05 | 0.00 | 01-JAN-10:30 | 2753.53 | 11-JAN-08:20 |
| Cooling:EnergyTransfer | 368.77 | 0.00 | 04-JAN-08:20 | 69787.14 | 17-JUL-16:00 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 9.87 | 0.00 | 01-JAN-00:10 | 2420.56 | 02-SEP-16:10 |
| General:Cooling:EnergyTransfer | 368.77 | 0.00 | 04-JAN-08:20 | 69787.14 | 17-JUL-16:00 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 9.87 | 0.00 | 01-JAN-00:10 | 2420.56 | 02-SEP-16:10 |
| EnergyTransfer:Zone:G NW APARTMENT | 18.76 | 0.06 | 15-OCT-15:20 | 2801.48 | 11-JAN-08:20 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 12.48 | 0.00 | 20-FEB-16:10 | 2801.48 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 12.48 | 0.00 | 20-FEB-16:10 | 2801.48 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 6.28 | 0.00 | 01-JAN-00:10 | 1996.18 | 17-JUL-17:50 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 6.28 | 0.00 | 01-JAN-00:10 | 1996.18 | 17-JUL-17:50 |
| EnergyTransfer:Zone:OFFICE | 14.15 | 0.01 | 10-MAY-13:20 | 5122.73 | 09-JAN-09:10 |
| Heating:EnergyTransfer:Zone:OFFICE | 5.31 | 0.00 | 01-JAN-00:10 | 5122.73 | 09-JAN-09:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 5.31 | 0.00 | 01-JAN-00:10 | 5122.73 | 09-JAN-09:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 8.84 | 0.00 | 03-JAN-07:20 | 3941.87 | 17-JUL-08:10 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 8.84 | 0.00 | 03-JAN-07:20 | 3941.87 | 17-JUL-08:10 |
| EnergyTransfer:Zone:G NE APARTMENT | 18.79 | 0.01 | 18-MAY-15:50 | 2794.75 | 11-JAN-08:10 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 12.29 | 0.00 | 26-FEB-12:50 | 2794.75 | 11-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 12.29 | 0.00 | 26-FEB-12:50 | 2794.75 | 11-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.50 | 0.00 | 01-JAN-00:10 | 1623.52 | 17-JUL-17:20 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.50 | 0.00 | 01-JAN-00:10 | 1623.52 | 17-JUL-17:20 |
| EnergyTransfer:Zone:G N1 APARTMENT | 12.24 | 0.02 | 09-APR-00:10 | 1767.85 | 11-JAN-08:20 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 6.08 | 0.00 | 01-JAN-19:00 | 1767.85 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 6.08 | 0.00 | 01-JAN-19:00 | 1767.85 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 6.16 | 0.00 | 01-JAN-00:10 | 1268.78 | 17-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 6.16 | 0.00 | 01-JAN-00:10 | 1268.78 | 17-JUL-18:30 |
| EnergyTransfer:Zone:G N2 APARTMENT | 12.25 | 0.01 | 11-MAR-17:00 | 1767.91 | 11-JAN-08:20 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 6.07 | 0.00 | 01-JAN-19:00 | 1767.91 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 6.07 | 0.00 | 01-JAN-19:00 | 1767.91 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 6.18 | 0.00 | 01-JAN-00:10 | 1263.20 | 17-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 6.18 | 0.00 | 01-JAN-00:10 | 1263.20 | 17-JUL-18:30 |
| EnergyTransfer:Zone:G S1 APARTMENT | 13.72 | 0.01 | 23-MAR-23:10 | 1901.38 | 02-SEP-15:10 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 2.92 | 0.00 | 01-JAN-00:10 | 1719.13 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 2.92 | 0.00 | 01-JAN-00:10 | 1719.13 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 10.80 | 0.00 | 03-JAN-03:00 | 1901.38 | 02-SEP-15:10 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 10.80 | 0.00 | 03-JAN-03:00 | 1901.38 | 02-SEP-15:10 |
| EnergyTransfer:Zone:G S2 APARTMENT | 14.92 | 0.02 | 27-APR-11:50 | 2022.59 | 02-SEP-15:10 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 3.65 | 0.00 | 01-JAN-00:10 | 1857.07 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 3.65 | 0.00 | 01-JAN-00:10 | 1857.07 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 11.26 | 0.00 | 01-JAN-05:40 | 2022.59 | 02-SEP-15:10 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 11.26 | 0.00 | 01-JAN-05:40 | 2022.59 | 02-SEP-15:10 |
| EnergyTransfer:Zone:M SW APARTMENT | 41.46 | 0.05 | 13-FEB-10:40 | 6175.59 | 02-SEP-15:20 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 9.89 | 0.00 | 01-JAN-00:10 | 4664.11 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 9.89 | 0.00 | 01-JAN-00:10 | 4664.11 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 31.57 | 0.00 | 01-JAN-04:10 | 6175.59 | 02-SEP-15:20 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 31.57 | 0.00 | 01-JAN-04:10 | 6175.59 | 02-SEP-15:20 |
| EnergyTransfer:Zone:M NW APARTMENT | 37.01 | 0.00 | 09-OCT-10:10 | 5232.05 | 17-JUL-17:50 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 16.01 | 0.00 | 01-JAN-17:10 | 4749.74 | 10-JAN-23:10 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 16.01 | 0.00 | 01-JAN-17:10 | 4749.74 | 10-JAN-23:10 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 21.00 | 0.00 | 01-JAN-00:10 | 5232.05 | 17-JUL-17:50 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 21.00 | 0.00 | 01-JAN-00:10 | 5232.05 | 17-JUL-17:50 |
| EnergyTransfer:Zone:M SE APARTMENT | 42.01 | 0.10 | 29-DEC-12:50 | 5759.47 | 02-SEP-14:00 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 9.73 | 0.00 | 01-JAN-00:10 | 4651.63 | 11-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 9.73 | 0.00 | 01-JAN-00:10 | 4651.63 | 11-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 32.28 | 0.00 | 01-JAN-04:40 | 5759.47 | 02-SEP-14:00 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 32.28 | 0.00 | 01-JAN-04:40 | 5759.47 | 02-SEP-14:00 |
| EnergyTransfer:Zone:M NE APARTMENT | 37.29 | 0.04 | 04-NOV-06:40 | 4726.76 | 10-JAN-23:10 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 15.71 | 0.00 | 01-JAN-17:10 | 4726.76 | 10-JAN-23:10 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 15.71 | 0.00 | 01-JAN-17:10 | 4726.76 | 10-JAN-23:10 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 21.58 | 0.00 | 01-JAN-00:10 | 4054.12 | 17-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 21.58 | 0.00 | 01-JAN-00:10 | 4054.12 | 17-JUL-16:10 |
| EnergyTransfer:Zone:M N1 APARTMENT | 25.89 | 0.04 | 25-NOV-23:00 | 3068.84 | 17-JUL-18:30 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 5.53 | 0.00 | 01-JAN-00:10 | 2498.38 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 5.53 | 0.00 | 01-JAN-00:10 | 2498.38 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 20.36 | 0.00 | 01-JAN-00:40 | 3068.84 | 17-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 20.36 | 0.00 | 01-JAN-00:40 | 3068.84 | 17-JUL-18:30 |
| EnergyTransfer:Zone:M N2 APARTMENT | 25.93 | 0.02 | 19-MAR-04:10 | 3050.13 | 17-JUL-18:30 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 5.52 | 0.00 | 01-JAN-00:10 | 2498.33 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 5.52 | 0.00 | 01-JAN-00:10 | 2498.33 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 20.41 | 0.00 | 01-JAN-00:40 | 3050.13 | 17-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 20.41 | 0.00 | 01-JAN-00:40 | 3050.13 | 17-JUL-18:30 |
| EnergyTransfer:Zone:M S1 APARTMENT | 35.94 | 0.02 | 12-JAN-22:40 | 4654.89 | 02-SEP-14:10 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 2.59 | 0.00 | 01-JAN-00:10 | 2412.84 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 2.59 | 0.00 | 01-JAN-00:10 | 2412.84 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 33.35 | 0.00 | 04-JAN-01:50 | 4654.89 | 02-SEP-14:10 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 33.35 | 0.00 | 04-JAN-01:50 | 4654.89 | 02-SEP-14:10 |
| EnergyTransfer:Zone:M S2 APARTMENT | 36.00 | 0.01 | 29-JAN-21:00 | 4666.36 | 02-SEP-14:10 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 2.58 | 0.00 | 01-JAN-00:10 | 2412.93 | 11-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 2.58 | 0.00 | 01-JAN-00:10 | 2412.93 | 11-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 33.41 | 0.00 | 04-JAN-01:50 | 4666.36 | 02-SEP-14:10 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 33.41 | 0.00 | 04-JAN-01:50 | 4666.36 | 02-SEP-14:10 |
| EnergyTransfer:Zone:T SW APARTMENT | 29.44 | 0.23 | 25-OCT-19:10 | 4122.61 | 02-SEP-15:20 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 15.45 | 0.00 | 01-JAN-11:00 | 4101.89 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 15.45 | 0.00 | 01-JAN-11:00 | 4101.89 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 13.99 | 0.00 | 01-JAN-00:10 | 4122.61 | 02-SEP-15:20 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 13.99 | 0.00 | 01-JAN-00:10 | 4122.61 | 02-SEP-15:20 |
| EnergyTransfer:Zone:T NW APARTMENT | 29.15 | 0.05 | 18-OCT-11:00 | 4132.15 | 10-JAN-23:10 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 19.78 | 0.00 | 14-JAN-15:20 | 4132.15 | 10-JAN-23:10 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 19.78 | 0.00 | 14-JAN-15:20 | 4132.15 | 10-JAN-23:10 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 9.37 | 0.00 | 01-JAN-00:10 | 3616.13 | 17-JUL-17:30 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 9.37 | 0.00 | 01-JAN-00:10 | 3616.13 | 17-JUL-17:30 |
| EnergyTransfer:Zone:T SE APARTMENT | 29.34 | 0.01 | 18-FEB-10:30 | 4079.49 | 11-JAN-01:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 15.22 | 0.00 | 01-JAN-10:20 | 4079.49 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 15.22 | 0.00 | 01-JAN-10:20 | 4079.49 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 14.12 | 0.00 | 01-JAN-00:10 | 3836.20 | 02-SEP-14:00 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 14.12 | 0.00 | 01-JAN-00:10 | 3836.20 | 02-SEP-14:00 |
| EnergyTransfer:Zone:T NE APARTMENT | 28.94 | 0.02 | 17-AUG-10:00 | 4109.52 | 10-JAN-23:10 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 19.47 | 0.00 | 12-FEB-15:40 | 4109.52 | 10-JAN-23:10 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 19.47 | 0.00 | 12-FEB-15:40 | 4109.52 | 10-JAN-23:10 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 9.47 | 0.00 | 01-JAN-00:10 | 2804.62 | 17-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 9.47 | 0.00 | 01-JAN-00:10 | 2804.62 | 17-JUL-16:10 |
| EnergyTransfer:Zone:T N1 APARTMENT | 19.13 | 0.01 | 01-APR-23:20 | 2728.97 | 11-JAN-01:00 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 11.26 | 0.00 | 14-JAN-13:40 | 2728.97 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 11.26 | 0.00 | 14-JAN-13:40 | 2728.97 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.87 | 0.00 | 01-JAN-00:10 | 2186.99 | 17-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.87 | 0.00 | 01-JAN-00:10 | 2186.99 | 17-JUL-16:10 |
| EnergyTransfer:Zone:T N2 APARTMENT | 19.16 | 0.02 | 23-NOV-23:20 | 2728.52 | 11-JAN-01:00 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 11.26 | 0.00 | 14-JAN-13:40 | 2728.52 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 11.26 | 0.00 | 14-JAN-13:40 | 2728.52 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.90 | 0.00 | 01-JAN-00:10 | 2177.12 | 17-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.90 | 0.00 | 01-JAN-00:10 | 2177.12 | 17-JUL-16:10 |
| EnergyTransfer:Zone:T S1 APARTMENT | 20.85 | 0.05 | 05-MAY-06:50 | 3194.60 | 02-SEP-14:00 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 7.78 | 0.00 | 01-JAN-09:50 | 2714.13 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 7.78 | 0.00 | 01-JAN-09:50 | 2714.13 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 13.08 | 0.00 | 01-JAN-00:10 | 3194.60 | 02-SEP-14:00 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 13.08 | 0.00 | 01-JAN-00:10 | 3194.60 | 02-SEP-14:00 |
| EnergyTransfer:Zone:T S2 APARTMENT | 20.91 | 0.00 | 12-MAR-22:10 | 3205.62 | 02-SEP-14:00 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 7.78 | 0.00 | 01-JAN-09:50 | 2713.68 | 11-JAN-01:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 7.78 | 0.00 | 01-JAN-09:50 | 2713.68 | 11-JAN-01:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 13.13 | 0.00 | 01-JAN-00:10 | 3205.62 | 02-SEP-14:00 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 13.13 | 0.00 | 01-JAN-00:10 | 3205.62 | 02-SEP-14:00 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 725.61 | 0.00 | 07-APR-20:50 | 113127.29 | 10-JAN-23:10 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 19-MAY-16:50 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 20-MAY-12:50 |
| HeatingCoils:EnergyTransfer | 468.94 | 0.00 | 27-FEB-14:10 | 113127.29 | 10-JAN-23:10 |
| CoolingCoils:EnergyTransfer | 256.67 | 0.00 | 01-JAN-00:10 | 90125.68 | 17-JUL-16:00 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 0.295 | -12.862 | 16.956 | -6.206 | 0.000 | 0.000 | 3.935 | 1.454 | 12.213 | 13.515 | 0.000 | 0.080 | 0.000 | 0.000 | -7.400 | 0.000 | -5.496 | -16.486 |
| G NW APARTMENT | 0.297 | -12.662 | 22.608 | -4.042 | 0.000 | 0.000 | 4.029 | 1.454 | 12.213 | 6.132 | 0.000 | 0.081 | 0.000 | 0.000 | -7.639 | 0.000 | -5.345 | -17.126 |
| OFFICE | 0.000 | 0.000 | 5.315 | -8.839 | 0.000 | 0.000 | 2.166 | 7.396 | 9.469 | 13.668 | 0.000 | 0.047 | 0.001 | 0.000 | -7.009 | 0.000 | -4.674 | -17.539 |
| G NE APARTMENT | 0.296 | -12.669 | 22.412 | -4.253 | 0.000 | 0.000 | 4.030 | 1.454 | 12.213 | 6.247 | 0.000 | 0.080 | 0.000 | 0.000 | -7.436 | 0.000 | -5.358 | -17.016 |
| G N1 APARTMENT | 0.297 | -12.716 | 15.706 | -3.367 | 0.000 | 0.000 | 4.016 | 1.454 | 12.213 | 2.047 | 0.000 | 0.049 | 0.000 | 0.000 | -4.812 | 0.000 | -3.466 | -11.421 |
| G N2 APARTMENT | 0.297 | -12.717 | 15.700 | -3.385 | 0.000 | 0.000 | 4.016 | 1.454 | 12.213 | 2.046 | 0.000 | 0.049 | 0.000 | 0.000 | -4.812 | 0.000 | -3.467 | -11.394 |
| G S1 APARTMENT | 0.295 | -12.984 | 10.568 | -5.763 | 0.000 | 0.000 | 3.908 | 1.454 | 12.213 | 9.512 | 0.000 | 0.048 | 0.000 | 0.000 | -4.544 | 0.000 | -3.609 | -11.097 |
| G S2 APARTMENT | 0.295 | -12.994 | 11.498 | -6.408 | 0.000 | 0.000 | 3.906 | 1.454 | 12.213 | 9.509 | 0.000 | 0.048 | 0.000 | 0.000 | -4.540 | 0.000 | -3.614 | -11.367 |
| M SW APARTMENT | 0.591 | -26.219 | 24.165 | -20.215 | 0.000 | 0.000 | 7.760 | 2.908 | 24.426 | 26.495 | 0.000 | 0.229 | 0.000 | 0.000 | -15.470 | 0.000 | -15.934 | -8.735 |
| M NW APARTMENT | 0.591 | -25.712 | 34.068 | -13.932 | 0.000 | 0.000 | 7.963 | 2.908 | 24.426 | 11.848 | 0.000 | 0.229 | 0.000 | 0.000 | -15.997 | 0.000 | -15.503 | -10.889 |
| M SE APARTMENT | 0.591 | -26.250 | 23.914 | -20.806 | 0.000 | 0.000 | 7.762 | 2.908 | 24.426 | 26.816 | 0.000 | 0.229 | 0.001 | 0.000 | -15.137 | 0.000 | -15.970 | -8.483 |
| M NE APARTMENT | 0.591 | -25.736 | 33.701 | -14.428 | 0.000 | 0.000 | 7.965 | 2.908 | 24.426 | 12.065 | 0.000 | 0.229 | 0.000 | 0.000 | -15.559 | 0.000 | -15.546 | -10.617 |
| M N1 APARTMENT | 0.591 | -25.834 | 21.330 | -10.922 | 0.000 | 0.000 | 7.935 | 2.908 | 24.426 | 3.902 | 0.000 | 0.138 | 0.000 | 0.000 | -10.045 | 0.000 | -10.008 | -4.421 |
| M N2 APARTMENT | 0.591 | -25.837 | 21.323 | -10.959 | 0.000 | 0.000 | 7.934 | 2.908 | 24.426 | 3.900 | 0.000 | 0.138 | 0.000 | 0.000 | -10.046 | 0.000 | -10.011 | -4.368 |
| M S1 APARTMENT | 0.591 | -26.549 | 12.885 | -17.691 | 0.000 | 0.000 | 7.687 | 2.908 | 24.426 | 18.724 | 0.000 | 0.138 | 0.002 | 0.000 | -9.484 | 0.000 | -10.408 | -3.227 |
| M S2 APARTMENT | 0.591 | -26.552 | 12.881 | -17.750 | 0.000 | 0.000 | 7.687 | 2.908 | 24.426 | 18.722 | 0.000 | 0.138 | 0.002 | 0.000 | -9.484 | 0.000 | -10.409 | -3.158 |
| T SW APARTMENT | 0.295 | -12.855 | 24.816 | -10.791 | 0.000 | 0.000 | 3.946 | 1.454 | 12.213 | 13.229 | 0.000 | 0.150 | 0.000 | 0.000 | -7.377 | 0.000 | -10.225 | -14.856 |
| T NW APARTMENT | 0.295 | -12.680 | 30.122 | -7.319 | 0.000 | 0.000 | 4.026 | 1.454 | 12.213 | 5.940 | 0.000 | 0.150 | 0.000 | 0.000 | -7.688 | 0.000 | -10.008 | -16.505 |
| T SE APARTMENT | 0.295 | -12.883 | 24.536 | -10.848 | 0.000 | 0.000 | 3.948 | 1.454 | 12.213 | 13.391 | 0.000 | 0.150 | 0.000 | 0.000 | -7.222 | 0.000 | -10.283 | -14.751 |
| T NE APARTMENT | 0.295 | -12.700 | 29.775 | -7.368 | 0.000 | 0.000 | 4.028 | 1.454 | 12.213 | 6.048 | 0.000 | 0.150 | 0.000 | 0.000 | -7.476 | 0.000 | -10.065 | -16.355 |
| T N1 APARTMENT | 0.295 | -12.718 | 21.257 | -5.449 | 0.000 | 0.000 | 4.016 | 1.454 | 12.213 | 1.971 | 0.000 | 0.090 | 0.000 | 0.000 | -4.840 | 0.000 | -6.397 | -11.892 |
| T N2 APARTMENT | 0.295 | -12.720 | 21.254 | -5.478 | 0.000 | 0.000 | 4.016 | 1.454 | 12.213 | 1.968 | 0.000 | 0.090 | 0.000 | 0.000 | -4.839 | 0.000 | -6.401 | -11.853 |
| T S1 APARTMENT | 0.295 | -12.960 | 16.227 | -8.864 | 0.000 | 0.000 | 3.923 | 1.454 | 12.213 | 9.365 | 0.000 | 0.090 | 0.000 | 0.000 | -4.527 | 0.000 | -6.608 | -10.609 |
| T S2 APARTMENT | 0.295 | -12.961 | 16.229 | -8.914 | 0.000 | 0.000 | 3.923 | 1.454 | 12.213 | 9.362 | 0.000 | 0.090 | 0.000 | 0.000 | -4.526 | 0.000 | -6.611 | -10.554 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.543 | 11.688 | 0.000 | 1.014 | 0.000 | 0.012 | 0.000 | 0.000 | -0.751 | 0.000 | -1.619 | -16.887 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.896 | 11.688 | 3.530 | 3.104 | 0.000 | 0.449 | 10.462 | 0.000 | -2.051 | 0.000 | -34.077 | -0.001 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 12.301 | 23.376 | 0.000 | 1.995 | 0.000 | 0.021 | 0.000 | 0.000 | -1.605 | 0.000 | -2.639 | -33.450 |
| Total Facility | 9.164 | -400.768 | 489.244 | -233.997 | 0.000 | 0.000 | 150.265 | 99.229 | 391.594 | 252.536 | 0.000 | 3.393 | 10.468 | 0.000 | -202.318 | 0.000 | -243.751 | -325.054 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 02-SEP-16:05 | 0.00 | 297.53 | 0.00 | -2718.26 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 1976.31 | 0.00 | 77.92 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -476.16 |
| G NW APARTMENT | 17-JUL-17:50 | 0.00 | 356.30 | 0.00 | -2352.47 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1816.70 | 0.00 | 51.86 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -723.68 |
| OFFICE | 01-AUG-07:01 | 0.00 | 0.00 | 0.00 | -6497.05 | 0.00 | 0.00 | 254.69 | 582.92 | 588.62 | 1178.65 | 0.00 | 0.00 | 3974.35 | 0.00 | -0.00 | 0.00 | -82.18 | 0.00 |
| G NE APARTMENT | 17-JUL-17:14 | 0.00 | 356.30 | 0.00 | -1980.08 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 603.71 | 0.00 | 68.42 | 100.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 17-JUL-18:30 | 0.00 | 332.69 | 0.00 | -1601.46 | 0.00 | 0.00 | 145.49 | 138.88 | 547.42 | 545.52 | 0.00 | 22.33 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -130.86 |
| G N2 APARTMENT | 17-JUL-18:30 | 0.00 | 332.69 | 0.00 | -1595.89 | 0.00 | 0.00 | 145.49 | 138.88 | 547.42 | 545.57 | 0.00 | 22.33 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -136.49 |
| G S1 APARTMENT | 02-SEP-15:10 | 0.00 | 306.82 | 0.00 | -2208.15 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 1360.39 | 0.00 | 80.42 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -238.36 |
| G S2 APARTMENT | 02-SEP-15:10 | 0.00 | 306.82 | 0.00 | -2329.37 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 1359.19 | 0.00 | 80.42 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -115.95 |
| M SW APARTMENT | 02-SEP-15:20 | 0.00 | 608.85 | 0.00 | -6784.47 | 0.00 | 0.00 | 334.45 | 121.52 | 941.80 | 5115.70 | 0.00 | 347.41 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -685.25 |
| M NW APARTMENT | 17-JUL-17:50 | 0.00 | 712.57 | 0.00 | -5944.58 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 3622.36 | 0.00 | 148.81 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -241.74 |
| M SE APARTMENT | 02-SEP-14:00 | 0.00 | 590.73 | 0.00 | -6349.60 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 4078.85 | 0.00 | 424.88 | 287.99 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 17-JUL-16:03 | 0.00 | 763.54 | 0.00 | -4818.39 | 0.00 | 0.00 | 173.91 | 173.60 | 1177.25 | 1379.95 | 0.00 | 301.45 | 848.69 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 17-JUL-18:30 | 0.00 | 665.35 | 0.00 | -3734.19 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1087.70 | 0.00 | 64.06 | 253.51 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 17-JUL-18:30 | 0.00 | 665.35 | 0.00 | -3715.48 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1087.84 | 0.00 | 64.06 | 234.66 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 02-SEP-14:10 | 0.00 | 595.39 | 0.00 | -5249.74 | 0.00 | 0.00 | 0.00 | 60.77 | 800.53 | 3488.07 | 0.00 | 255.70 | 49.29 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 02-SEP-14:10 | 0.00 | 595.39 | 0.00 | -5261.21 | 0.00 | 0.00 | 0.00 | 60.77 | 800.53 | 3487.97 | 0.00 | 255.70 | 60.86 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 02-SEP-15:20 | 0.00 | 304.41 | 0.00 | -4427.02 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 2531.18 | 0.00 | 228.88 | 663.67 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 17-JUL-17:30 | 0.00 | 356.28 | 0.00 | -3972.40 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1825.01 | 0.00 | 118.98 | 820.85 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 02-SEP-14:00 | 0.00 | 295.35 | 0.00 | -4131.13 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 2014.80 | 0.00 | 279.89 | 1057.52 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 17-JUL-16:07 | 0.00 | 381.77 | 0.00 | -3187.16 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 673.74 | 0.00 | 198.77 | 1170.50 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 17-JUL-16:04 | 0.00 | 381.80 | 0.00 | -2568.97 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 411.63 | 0.00 | 119.89 | 893.27 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 17-JUL-16:04 | 0.00 | 381.80 | 0.00 | -2559.10 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 411.72 | 0.00 | 119.89 | 883.32 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 02-SEP-14:00 | 0.00 | 295.40 | 0.00 | -3489.69 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1777.65 | 0.00 | 168.82 | 764.24 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 02-SEP-14:00 | 0.00 | 295.40 | 0.00 | -3500.71 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1777.55 | 0.00 | 168.82 | 775.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 17-JUL-16:07 | 0.00 | 11833.43 | 0.00 | -81961.26 | 0.00 | 0.00 | 1837.96 | 4289.87 | 18750.02 | 30209.01 | 0.00 | 6933.32 | 8107.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 11-JAN-08:13 | -993.01 | 0.00 | 3747.63 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -720.45 | 0.00 | -575.52 | -1873.19 |
| G NW APARTMENT | 11-JAN-08:13 | -993.01 | 0.00 | 3795.68 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -723.18 | 0.00 | -575.52 | -1994.55 |
| OFFICE | 12-JAN-07:01 | 0.00 | 0.00 | 10005.14 | 0.00 | 0.00 | 0.00 | 0.00 | 116.58 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -236.65 | 0.00 | -295.87 | -9883.51 |
| G NE APARTMENT | 11-JAN-08:10 | -1036.55 | 0.00 | 3831.78 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -775.38 | 0.00 | -560.71 | -1949.72 |
| G N1 APARTMENT | 11-JAN-08:13 | -993.06 | 0.00 | 2762.07 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -437.79 | 0.00 | -347.14 | -1474.66 |
| G N2 APARTMENT | 11-JAN-08:13 | -993.06 | 0.00 | 2762.13 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -437.79 | 0.00 | -347.14 | -1474.72 |
| G S1 APARTMENT | 11-JAN-08:15 | -993.05 | 0.00 | 2713.01 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -434.39 | 0.00 | -347.14 | -1352.97 |
| G S2 APARTMENT | 11-JAN-08:15 | -993.05 | 0.00 | 2851.05 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -432.93 | 0.00 | -347.14 | -1492.46 |
| M SW APARTMENT | 11-JAN-08:12 | -1985.93 | 0.00 | 6651.85 | 0.00 | 0.00 | 0.00 | 0.00 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1491.70 | 0.00 | -1655.02 | -2348.27 |
| M NW APARTMENT | 10-JAN-23:10 | -2964.17 | 0.00 | 7713.89 | 0.00 | 0.00 | 0.00 | 389.98 | 43.40 | 682.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2285.53 | 0.00 | -1470.31 | -2110.06 |
| M SE APARTMENT | 11-JAN-08:02 | -2073.02 | 0.00 | 6726.37 | 0.00 | 0.00 | 0.00 | 0.00 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1633.53 | 0.00 | -1612.41 | -2236.48 |
| M NE APARTMENT | 10-JAN-23:10 | -2964.17 | 0.00 | 7690.91 | 0.00 | 0.00 | 0.00 | 389.98 | 43.40 | 682.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2257.00 | 0.00 | -1470.31 | -2115.62 |
| M N1 APARTMENT | 11-JAN-01:00 | -2830.64 | 0.00 | 5329.03 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 529.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1314.72 | 0.00 | -751.69 | -1369.08 |
| M N2 APARTMENT | 11-JAN-01:00 | -2830.64 | 0.00 | 5328.98 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 529.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1314.72 | 0.00 | -751.69 | -1369.03 |
| M S1 APARTMENT | 11-JAN-08:15 | -1986.06 | 0.00 | 4400.66 | 0.00 | 0.00 | 0.00 | 0.00 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -897.44 | 0.00 | -998.27 | -1347.96 |
| M S2 APARTMENT | 11-JAN-08:15 | -1986.06 | 0.00 | 4400.74 | 0.00 | 0.00 | 0.00 | 0.00 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -897.44 | 0.00 | -998.27 | -1348.04 |
| T SW APARTMENT | 11-JAN-01:00 | -1415.10 | 0.00 | 5516.99 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1091.70 | 0.00 | -824.90 | -2653.85 |
| T NW APARTMENT | 10-JAN-23:10 | -1482.01 | 0.00 | 5614.13 | 0.00 | 0.00 | 0.00 | 194.99 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1122.62 | 0.00 | -973.19 | -2594.41 |
| T SE APARTMENT | 11-JAN-01:00 | -1415.10 | 0.00 | 5494.60 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1078.01 | 0.00 | -824.90 | -2645.14 |
| T NE APARTMENT | 10-JAN-23:10 | -1482.01 | 0.00 | 5591.50 | 0.00 | 0.00 | 0.00 | 194.99 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1107.47 | 0.00 | -973.19 | -2586.93 |
| T N1 APARTMENT | 11-JAN-01:00 | -1415.25 | 0.00 | 4144.23 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -645.86 | 0.00 | -497.56 | -2054.11 |
| T N2 APARTMENT | 11-JAN-01:00 | -1415.25 | 0.00 | 4143.77 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -645.86 | 0.00 | -497.56 | -2053.66 |
| T S1 APARTMENT | 11-JAN-01:00 | -1415.24 | 0.00 | 4129.37 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -666.93 | 0.00 | -497.56 | -2018.21 |
| T S2 APARTMENT | 11-JAN-01:00 | -1415.24 | 0.00 | 4128.92 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -666.93 | 0.00 | -497.56 | -2017.75 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 11-JAN-08:61 | -32132.39 | 0.00 | 111790.26 | 0.00 | 0.00 | 0.00 | 2204.12 | 2872.71 | 12840.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -20985.24 | 0.00 | -23108.46 | -53481.25 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.4041 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4041 | 0.0642 | 1.0000 | Not calculated | 0.0260 | 0.0642 | ||
| SPLIT GNW | 0.3699 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3699 | 0.0702 | 1.0000 | Not calculated | 0.0260 | 0.0702 | ||
| SPLIT OFFICE | 0.4241 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4241 | 0.0899 | 1.0000 | Not calculated | 0.0381 | 0.0899 | ||
| SPLIT GNE | 0.3261 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3261 | 0.0796 | 1.0000 | Not calculated | 0.0260 | 0.0796 | ||
| SPLIT GN1 | 0.2939 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2939 | 0.0883 | 1.0000 | Not calculated | 0.0260 | 0.0883 | ||
| SPLIT GN2 | 0.2932 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2932 | 0.0885 | 1.0000 | Not calculated | 0.0260 | 0.0885 | ||
| SPLIT GS1 | 0.3313 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3313 | 0.0783 | 1.0000 | Not calculated | 0.0260 | 0.0783 | ||
| SPLIT GS2 | 0.3334 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3334 | 0.0778 | 1.0000 | Not calculated | 0.0260 | 0.0778 | ||
| SPLIT MSW | 1.0225 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 1.0225 | 0.0508 | 1.0000 | Not calculated | 0.0519 | 0.0508 | ||
| SPLIT MNW | 0.9640 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9640 | 0.0538 | 1.0000 | Not calculated | 0.0519 | 0.0538 | ||
| SPLIT MSE | 0.8821 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8821 | 0.0588 | 1.0000 | Not calculated | 0.0519 | 0.0588 | ||
| SPLIT MNE | 0.8257 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8257 | 0.0629 | 1.0000 | Not calculated | 0.0519 | 0.0629 | ||
| SPLIT MN1 | 0.7337 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7337 | 0.0707 | 1.0000 | Not calculated | 0.0519 | 0.0707 | ||
| SPLIT MN2 | 0.7317 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7317 | 0.0709 | 1.0000 | Not calculated | 0.0519 | 0.0709 | ||
| SPLIT MS1 | 0.7992 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7992 | 0.0649 | 1.0000 | Not calculated | 0.0519 | 0.0649 | ||
| SPLIT MS2 | 0.7970 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7970 | 0.0651 | 1.0000 | Not calculated | 0.0519 | 0.0651 | ||
| SPLIT TSW | 0.5692 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5692 | 0.0456 | 1.0000 | Not calculated | 0.0260 | 0.0456 | ||
| SPLIT TNW | 0.5499 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5499 | 0.0472 | 1.0000 | Not calculated | 0.0260 | 0.0472 | ||
| SPLIT TSE | 0.4673 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4673 | 0.0555 | 1.0000 | Not calculated | 0.0260 | 0.0555 | ||
| SPLIT TNE | 0.4482 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4482 | 0.0579 | 1.0000 | Not calculated | 0.0260 | 0.0579 | ||
| SPLIT TN1 | 0.4164 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4164 | 0.0623 | 1.0000 | Not calculated | 0.0260 | 0.0623 | ||
| SPLIT TN2 | 0.4135 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4135 | 0.0628 | 1.0000 | Not calculated | 0.0260 | 0.0628 | ||
| SPLIT TS1 | 0.4379 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4379 | 0.0593 | 1.0000 | Not calculated | 0.0260 | 0.0593 | ||
| SPLIT TS2 | 0.4350 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4350 | 0.0597 | 1.0000 | Not calculated | 0.0260 | 0.0597 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.4041 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4041 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0642 | ||
| SPLIT GNW | 0.3699 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3699 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0702 | ||
| SPLIT OFFICE | 0.4241 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4241 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0899 | ||
| SPLIT GNE | 0.3261 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3261 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0796 | ||
| SPLIT GN1 | 0.2939 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2939 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0883 | ||
| SPLIT GN2 | 0.2932 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2932 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0885 | ||
| SPLIT GS1 | 0.3313 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3313 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0783 | ||
| SPLIT GS2 | 0.3334 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3334 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0778 | ||
| SPLIT MSW | 1.0225 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 1.0225 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0508 | ||
| SPLIT MNW | 0.9640 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9640 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0538 | ||
| SPLIT MSE | 0.8821 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8821 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0588 | ||
| SPLIT MNE | 0.8257 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8257 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0629 | ||
| SPLIT MN1 | 0.7337 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7337 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0707 | ||
| SPLIT MN2 | 0.7317 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7317 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0709 | ||
| SPLIT MS1 | 0.7992 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7992 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0649 | ||
| SPLIT MS2 | 0.7970 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7970 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0651 | ||
| SPLIT TSW | 0.5692 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5692 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0456 | ||
| SPLIT TNW | 0.5499 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5499 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0472 | ||
| SPLIT TSE | 0.4673 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4673 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0555 | ||
| SPLIT TNE | 0.4482 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4482 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0579 | ||
| SPLIT TN1 | 0.4164 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4164 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0623 | ||
| SPLIT TN2 | 0.4135 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4135 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0628 | ||
| SPLIT TS1 | 0.4379 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4379 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0593 | ||
| SPLIT TS2 | 0.4350 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4350 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0597 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4041 | 0.4041 | 0.4041 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3699 | 0.3699 | 0.3699 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4241 | 0.4241 | 0.4241 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3261 | 0.3261 | 0.3261 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2939 | 0.2939 | 0.2939 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2932 | 0.2932 | 0.2932 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3313 | 0.3313 | 0.3313 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3334 | 0.3334 | 0.3334 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0225 | 1.0225 | 1.0225 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9640 | 0.9640 | 0.9640 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8821 | 0.8821 | 0.8821 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8257 | 0.8257 | 0.8257 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7337 | 0.7337 | 0.7337 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7317 | 0.7317 | 0.7317 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7992 | 0.7992 | 0.7992 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7970 | 0.7970 | 0.7970 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5692 | 0.5692 | 0.5692 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5499 | 0.5499 | 0.5499 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4673 | 0.4673 | 0.4673 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4482 | 0.4482 | 0.4482 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4164 | 0.4164 | 0.4164 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4135 | 0.4135 | 0.4135 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4379 | 0.4379 | 0.4379 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4350 | 0.4350 | 0.4350 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.4041 | 0.4041 | 0.4041 | 0.4041 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3699 | 0.3699 | 0.3699 | 0.3699 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4241 | 0.4241 | 0.4241 | 0.4241 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3261 | 0.3261 | 0.3261 | 0.3261 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2939 | 0.2939 | 0.2939 | 0.2939 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2932 | 0.2932 | 0.2932 | 0.2932 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3313 | 0.3313 | 0.3313 | 0.3313 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3334 | 0.3334 | 0.3334 | 0.3334 | 0.0260 | 1.0000 |
| SPLIT MSW | 1.0225 | 1.0225 | 1.0225 | 1.0225 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.9640 | 0.9640 | 0.9640 | 0.9640 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.8821 | 0.8821 | 0.8821 | 0.8821 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.8257 | 0.8257 | 0.8257 | 0.8257 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.7337 | 0.7337 | 0.7337 | 0.7337 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.7317 | 0.7317 | 0.7317 | 0.7317 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7992 | 0.7992 | 0.7992 | 0.7992 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.7970 | 0.7970 | 0.7970 | 0.7970 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5692 | 0.5692 | 0.5692 | 0.5692 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.5499 | 0.5499 | 0.5499 | 0.5499 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4673 | 0.4673 | 0.4673 | 0.4673 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4482 | 0.4482 | 0.4482 | 0.4482 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.4164 | 0.4164 | 0.4164 | 0.4164 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.4135 | 0.4135 | 0.4135 | 0.4135 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.4379 | 0.4379 | 0.4379 | 0.4379 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.4350 | 0.4350 | 0.4350 | 0.4350 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4041 | 0.4041 | 0.4041 | No | 0.0260 | 0.1500 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3699 | 0.3699 | 0.3699 | No | 0.0260 | 0.1576 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4241 | 0.4241 | 0.4241 | No | 0.0381 | 0.1864 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3261 | 0.3261 | 0.3261 | No | 0.0260 | 0.1582 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2939 | 0.2939 | 0.2939 | No | 0.0260 | 0.2441 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2932 | 0.2932 | 0.2932 | No | 0.0260 | 0.2441 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3313 | 0.3313 | 0.3313 | No | 0.0260 | 0.2261 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3334 | 0.3334 | 0.3334 | No | 0.0260 | 0.2250 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0225 | 1.0225 | 1.0225 | No | 0.0519 | 0.1796 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9640 | 0.9640 | 0.9640 | No | 0.0519 | 0.1928 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8821 | 0.8821 | 0.8821 | No | 0.0519 | 0.1806 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8257 | 0.8257 | 0.8257 | No | 0.0519 | 0.1939 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7337 | 0.7337 | 0.7337 | No | 0.0519 | 0.3486 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7317 | 0.7317 | 0.7317 | No | 0.0519 | 0.3487 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7992 | 0.7992 | 0.7992 | No | 0.0519 | 0.3083 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7970 | 0.7970 | 0.7970 | No | 0.0519 | 0.3083 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5692 | 0.5692 | 0.5692 | No | 0.0260 | 0.1100 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5499 | 0.5499 | 0.5499 | No | 0.0260 | 0.1153 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4673 | 0.4673 | 0.4673 | No | 0.0260 | 0.1105 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4482 | 0.4482 | 0.4482 | No | 0.0260 | 0.1159 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4164 | 0.4164 | 0.4164 | No | 0.0260 | 0.1697 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4135 | 0.4135 | 0.4135 | No | 0.0260 | 0.1698 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4379 | 0.4379 | 0.4379 | No | 0.0260 | 0.1584 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4350 | 0.4350 | 0.4350 | No | 0.0260 | 0.1584 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.4041 | 0.4041 | 0.4041 | 0.4041 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3699 | 0.3699 | 0.3699 | 0.3699 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4241 | 0.4241 | 0.4241 | 0.4241 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3261 | 0.3261 | 0.3261 | 0.3261 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2939 | 0.2939 | 0.2939 | 0.2939 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2932 | 0.2932 | 0.2932 | 0.2932 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3313 | 0.3313 | 0.3313 | 0.3313 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3334 | 0.3334 | 0.3334 | 0.3334 | 0.0260 | 1.0000 |
| SPLIT MSW | 1.0225 | 1.0225 | 1.0225 | 1.0225 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.9640 | 0.9640 | 0.9640 | 0.9640 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.8821 | 0.8821 | 0.8821 | 0.8821 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.8257 | 0.8257 | 0.8257 | 0.8257 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.7337 | 0.7337 | 0.7337 | 0.7337 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.7317 | 0.7317 | 0.7317 | 0.7317 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7992 | 0.7992 | 0.7992 | 0.7992 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.7970 | 0.7970 | 0.7970 | 0.7970 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5692 | 0.5692 | 0.5692 | 0.5692 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.5499 | 0.5499 | 0.5499 | 0.5499 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4673 | 0.4673 | 0.4673 | 0.4673 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4482 | 0.4482 | 0.4482 | 0.4482 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.4164 | 0.4164 | 0.4164 | 0.4164 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.4135 | 0.4135 | 0.4135 | 0.4135 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.4379 | 0.4379 | 0.4379 | 0.4379 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.4350 | 0.4350 | 0.4350 | 0.4350 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 586.17 | 141409.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 68.07 | 27058.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 49.94 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 96.57 | 9196.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 495.68 | 40913.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1268.14 |
| Natural Gas | 0.00 | 586.17 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1854.32 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 21.72 |
| Fans (All) | 30.81 |
| Service Water Heating | 158.13 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 404.56 |
| Subtotal | 404.56 |
| Natural Gas [MJ/m2] | |
| Space Heating | 187.00 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 187.00 |
| Subtotal | 187.00 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 5.35 |
| Space Heating | 31.61 |
| Space Cooling | 3.67 |
| Fans (All) | 5.21 |
| Service Water Heating | 26.73 |
| Receptacle Equipment | 24.73 |
| Miscellaneous | 2.69 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 8206.67 | 553.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 7725.83 | 1022.50 | 11.67 | 0.00 | 0.00 |
| G CORRIDOR | 8597.83 | 162.17 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 6757.67 | 2002.33 | 0.00 | 0.00 | 0.00 |
| Min | 6757.67 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 2002.33 | 11.67 | 0.00 | 0.00 |
| Average | 8621.04 | 138.53 | 0.43 | 0.00 | 0.00 |
| Sum | 232768.00 | 3740.33 | 11.67 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 20524.33 | 2431.33 | 39.33 | 0.00 | 0.00 |
| G CORRIDOR | 22555.33 | 439.67 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 17777.17 | 5217.83 | 0.00 | 0.00 | 0.00 |
| Min | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 22555.33 | 5217.83 | 39.33 | 0.00 | 0.00 |
| Average | 12037.29 | 299.59 | 1.46 | 0.00 | 0.00 |
| Sum | 325006.83 | 8088.83 | 39.33 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 8575.50 | 184.50 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 5838.50 | 2889.83 | 31.67 | 0.00 | 0.00 |
| G CORRIDOR | 8346.50 | 413.50 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 4100.33 | 4591.67 | 68.00 | 0.00 | 0.00 |
| Min | 4100.33 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 4591.67 | 68.00 | 0.00 | 0.00 |
| Average | 8457.07 | 299.24 | 3.69 | 0.00 | 0.00 |
| Sum | 228340.83 | 8079.50 | 99.67 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6998.67 | 1.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 15241.50 | 7642.17 | 111.33 | 0.00 | 0.00 |
| G CORRIDOR | 21471.33 | 1523.67 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 10718.33 | 12057.50 | 219.17 | 0.00 | 0.00 |
| Min | 6998.67 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 21471.33 | 12057.50 | 219.17 | 0.00 | 0.00 |
| Average | 11539.99 | 786.10 | 12.24 | 0.00 | 0.00 |
| Sum | 311579.83 | 21224.67 | 330.50 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:37
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -8.80 |
| February | -2.17 |
| March | 0.301 |
| April | 6.668 |
| May | 10.099 |
| June | 16.456 |
| July | 20.571 |
| August | 19.174 |
| September | 14.689 |
| October | 8.635 |
| November | 2.839 |
| December | -4.07 |
| Annual Sum or Average | 7.074 |
| Minimum of Months | -8.80 |
| Maximum of Months | 20.571 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 33718677.51 | 439.53 | 15-JAN-15:40 | 4.47 | -0.8 | 78222879.45 | 43.34 | 14-JAN-16:10 | 4.47 | -0.8 |
| February | 0.114103E+09 | 570.94 | 28-FEB-22:25 | -0.2 | -1.8 | 70654237.76 | 67.55 | 26-FEB-17:19 | -0.2 | -1.8 |
| March | 0.140102E+09 | 557.11 | 01-MAR-20:00 | 0.60 | -1.0 | 75334293.20 | 55.35 | 01-MAR-18:10 | 0.60 | -1.0 |
| April | 0.216825E+09 | 445.94 | 25-APR-24:00 | 4.40 | 2.16 | 78358841.89 | 70.34 | 06-APR-17:49 | 4.40 | 2.16 |
| May | 0.465470E+09 | 933.59 | 19-MAY-16:07 | 27.52 | 14.54 | 90467154.58 | 70.40 | 19-MAY-22:19 | 18.53 | 11.58 |
| June | 0.122853E+10 | 1682.35 | 24-JUN-16:20 | 28.13 | 12.84 | 0.109393E+09 | 70.40 | 06-JUN-00:30 | 28.13 | 12.84 |
| July | 0.227327E+10 | 2268.83 | 17-JUL-17:16 | 36.10 | 16.88 | 0.127863E+09 | 70.38 | 29-JUL-08:09 | 15.87 | 10.14 |
| August | 0.219364E+10 | 2310.16 | 10-AUG-17:07 | 32.02 | 13.58 | 0.121643E+09 | 70.37 | 16-AUG-03:30 | 12.80 | 10.28 |
| September | 0.167936E+10 | 2420.71 | 02-SEP-16:05 | 33.98 | 16.34 | 0.112145E+09 | 70.37 | 28-SEP-19:49 | 11.10 | 7.14 |
| October | 0.102757E+10 | 1720.16 | 18-OCT-16:10 | 23.95 | 10.92 | 0.101085E+09 | 70.36 | 15-OCT-23:10 | 23.95 | 10.92 |
| November | 0.459630E+09 | 672.43 | 11-NOV-11:50 | -4.0 | -5.7 | 78863302.11 | 68.29 | 03-NOV-17:10 | -4.0 | -5.7 |
| December | 38019657.20 | 388.34 | 07-DEC-16:10 | 6.32 | 2.06 | 78198344.16 | 42.51 | 28-DEC-18:00 | -22.8 | -23.1 |
| Annual Sum or Average | 0.987024E+10 | 0.112223E+10 | ||||||||
| Minimum of Months | 33718677.51 | 388.34 | -4.0 | -5.7 | 70654237.76 | 42.51 | -22.8 | -23.1 | ||
| Maximum of Months | 0.227327E+10 | 2420.71 | 36.10 | 16.88 | 0.127863E+09 | 70.40 | 28.13 | 12.84 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.3 | 77895344.68 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 5335899.80 | 268.88 | 26-FEB-18:02 | 10.63 | 3.80 | 70365181.84 | 42.51 | 10-FEB-22:49 | 10.63 | 3.80 |
| March | 6207336.26 | 247.28 | 29-MAR-17:04 | 11.42 | 3.32 | 77894473.31 | 42.51 | 05-MAR-06:49 | 11.42 | 3.32 |
| April | 58786908.13 | 310.99 | 10-APR-18:30 | 9.15 | 2.26 | 76172571.28 | 49.67 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.296272E+09 | 696.34 | 31-MAY-18:00 | 23.90 | 10.10 | 87641304.37 | 70.38 | 31-MAY-20:49 | 17.67 | 8.10 |
| June | 0.999873E+09 | 1512.32 | 30-JUN-18:30 | 28.30 | 14.04 | 0.110650E+09 | 70.38 | 26-JUN-03:49 | 28.30 | 14.04 |
| July | 0.182193E+10 | 1996.18 | 17-JUL-17:50 | 36.10 | 16.71 | 0.126874E+09 | 70.38 | 29-JUL-02:39 | 12.43 | 8.03 |
| August | 0.152616E+10 | 1847.13 | 10-AUG-17:27 | 31.65 | 13.18 | 0.124541E+09 | 70.39 | 20-AUG-20:19 | 17.37 | 12.37 |
| September | 0.999138E+09 | 1737.54 | 04-SEP-17:07 | 32.62 | 16.70 | 0.104234E+09 | 70.36 | 25-SEP-22:49 | 16.88 | 10.84 |
| October | 0.487772E+09 | 548.91 | 21-OCT-00:40 | 0.57 | -0.7 | 85643602.90 | 62.80 | 19-OCT-20:10 | 0.57 | -0.7 |
| November | 76375643.75 | 341.63 | 05-NOV-20:10 | 8.05 | 3.46 | 75597595.01 | 47.25 | 04-NOV-20:10 | 8.05 | 3.46 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 77895344.65 | 42.51 | 03-DEC-22:49 | 0.92 | -2.7 |
| Annual Sum or Average | 0.627785E+10 | 0.109540E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -2.1 | -4.2 | 70365181.84 | 42.51 | -1.3 | -3.5 | ||
| Maximum of Months | 0.182193E+10 | 1996.18 | 36.10 | 16.71 | 0.126874E+09 | 70.39 | 28.30 | 14.04 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.314016E+09 | 1465.40 | 11-JAN-07:03 | -27.2 | -27.6 | 38868389.40 | 80.76 | 03-JAN-13:39 | -27.2 | -27.6 |
| February | 0.327148E+09 | 1429.49 | 01-FEB-08:03 | -24.3 | -24.6 | 38775960.62 | 133.51 | 27-FEB-16:49 | 13.32 | 5.75 |
| March | 0.421532E+09 | 1160.61 | 06-MAR-07:03 | -19.7 | -20.3 | 46922625.48 | 129.69 | 01-MAR-16:19 | -19.7 | -20.3 |
| April | 0.276251E+09 | 586.97 | 04-APR-07:02 | 0.47 | -0.4 | 47516435.04 | 133.57 | 25-APR-12:09 | 15.28 | 6.55 |
| May | 0.307325E+09 | 2309.10 | 19-MAY-08:63 | 16.38 | 10.89 | 57482708.01 | 151.50 | 19-MAY-08:09 | 16.38 | 10.89 |
| June | 0.992971E+09 | 6334.80 | 26-JUN-07:02 | 17.67 | 12.36 | 75455338.21 | 198.61 | 23-JUN-07:10 | 17.67 | 12.36 |
| July | 0.160254E+10 | 6459.07 | 27-JUL-07:01 | 13.98 | 10.41 | 70354909.30 | 217.47 | 18-JUL-07:10 | 13.98 | 10.41 |
| August | 0.172290E+10 | 6496.88 | 01-AUG-07:01 | 14.78 | 11.37 | 80533815.53 | 218.01 | 08-AUG-07:10 | 19.60 | 12.40 |
| September | 0.106700E+10 | 6408.55 | 05-SEP-07:02 | 18.98 | 12.62 | 67014644.17 | 217.47 | 05-SEP-07:10 | 18.98 | 12.62 |
| October | 0.773972E+09 | 5615.89 | 19-OCT-08:62 | 14.37 | 6.93 | 64934049.79 | 166.74 | 19-OCT-08:09 | 14.37 | 6.93 |
| November | 0.575893E+09 | 964.34 | 27-NOV-08:03 | -12.7 | -13.6 | 49289144.10 | 133.51 | 01-NOV-15:00 | -12.7 | -13.6 |
| December | 0.457738E+09 | 1422.19 | 29-DEC-07:03 | -26.0 | -26.3 | 39109518.88 | 93.61 | 07-DEC-13:00 | -26.0 | -26.3 |
| Annual Sum or Average | 0.883929E+10 | 0.676258E+09 | ||||||||
| Minimum of Months | 0.276251E+09 | 586.97 | -27.2 | -27.6 | 38775960.62 | 80.76 | -27.2 | -27.6 | ||
| Maximum of Months | 0.172290E+10 | 6496.88 | 18.98 | 12.62 | 80533815.53 | 218.01 | 19.60 | 12.62 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.3 | 77895344.69 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 1979902.55 | 164.40 | 27-FEB-16:40 | 14.43 | 6.12 | 70359375.16 | 42.51 | 10-FEB-22:49 | 14.43 | 6.12 |
| March | 602096.26 | 247.28 | 29-MAR-17:04 | 11.42 | 3.32 | 77894222.55 | 42.51 | 05-MAR-06:49 | 11.42 | 3.32 |
| April | 68066547.81 | 303.18 | 25-APR-09:00 | 9.40 | 4.65 | 75884712.53 | 46.55 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.278346E+09 | 490.52 | 20-MAY-16:10 | 29.82 | 15.10 | 86769827.48 | 70.27 | 20-MAY-20:10 | 19.63 | 12.03 |
| June | 0.105746E+10 | 1231.24 | 29-JUN-16:02 | 30.63 | 14.01 | 0.110676E+09 | 70.38 | 05-JUN-22:19 | 30.63 | 14.01 |
| July | 0.193013E+10 | 1623.78 | 17-JUL-17:14 | 36.10 | 16.88 | 0.126899E+09 | 70.38 | 10-JUL-01:30 | 36.10 | 16.88 |
| August | 0.160948E+10 | 1574.90 | 06-AUG-17:30 | 34.15 | 15.38 | 0.125070E+09 | 70.39 | 22-AUG-00:49 | 16.28 | 10.89 |
| September | 0.997500E+09 | 1462.83 | 03-SEP-16:15 | 32.93 | 15.91 | 0.104331E+09 | 70.39 | 25-SEP-22:40 | 17.07 | 10.92 |
| October | 0.486505E+09 | 556.59 | 21-OCT-00:50 | 0.28 | -0.9 | 85335944.13 | 63.15 | 19-OCT-20:10 | 0.28 | -0.9 |
| November | 71897140.29 | 334.05 | 05-NOV-20:00 | 8.30 | 3.64 | 75517192.72 | 46.27 | 04-NOV-20:10 | 8.30 | 3.64 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 77895344.66 | 42.51 | 03-DEC-22:49 | 0.92 | -2.7 |
| Annual Sum or Average | 0.650196E+10 | 0.109453E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -2.1 | -4.2 | 70359375.16 | 42.51 | -1.3 | -3.5 | ||
| Maximum of Months | 0.193013E+10 | 1623.78 | 36.10 | 16.88 | 0.126899E+09 | 70.39 | 36.10 | 16.88 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1870.83 | 3.12 | 01-JAN-19:00 | 2.80 | -0.3 | 77895344.68 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 9435879.32 | 251.73 | 27-FEB-17:12 | 11.27 | 4.96 | 70361302.71 | 42.51 | 10-FEB-22:49 | 11.27 | 4.96 |
| March | 11789032.13 | 247.29 | 29-MAR-17:04 | 11.42 | 3.32 | 77894749.22 | 42.51 | 05-MAR-06:49 | 11.42 | 3.32 |
| April | 0.109703E+09 | 325.61 | 08-APR-19:30 | 8.60 | 2.11 | 75995818.93 | 47.63 | 07-APR-21:49 | 8.60 | 2.11 |
| May | 0.359423E+09 | 497.32 | 22-MAY-01:30 | 2.50 | 1.85 | 88076805.50 | 70.29 | 31-MAY-21:49 | 16.70 | 8.85 |
| June | 0.923616E+09 | 979.20 | 29-JUN-18:00 | 28.30 | 12.43 | 0.114254E+09 | 70.40 | 10-JUN-21:00 | 28.30 | 12.43 |
| July | 0.155911E+10 | 1268.78 | 17-JUL-18:30 | 35.25 | 16.50 | 0.127760E+09 | 70.38 | 24-JUL-04:49 | 12.88 | 9.71 |
| August | 0.134015E+10 | 1219.78 | 06-AUG-17:30 | 34.15 | 15.38 | 0.126555E+09 | 70.39 | 27-AUG-02:49 | 13.22 | 10.04 |
| September | 0.978672E+09 | 1147.62 | 04-SEP-17:20 | 32.43 | 16.63 | 0.107031E+09 | 70.39 | 27-SEP-22:40 | 14.97 | 8.45 |
| October | 0.675068E+09 | 600.74 | 21-OCT-04:00 | -1.1 | -2.0 | 88671077.17 | 65.30 | 19-OCT-20:10 | -1.1 | -2.0 |
| November | 0.188055E+09 | 408.03 | 05-NOV-21:50 | 5.63 | 1.83 | 75893287.12 | 49.50 | 04-NOV-20:10 | 5.63 | 1.83 |
| December | 2811451.28 | 104.84 | 06-DEC-17:02 | 6.52 | 2.26 | 77895344.66 | 42.51 | 29-DEC-22:00 | -22.2 | -22.6 |
| Annual Sum or Average | 0.615783E+10 | 0.110828E+10 | ||||||||
| Minimum of Months | 1870.83 | 3.12 | -1.1 | -2.0 | 70361302.71 | 42.51 | -22.2 | -22.6 | ||
| Maximum of Months | 0.155911E+10 | 1268.78 | 35.25 | 16.63 | 0.127760E+09 | 70.40 | 28.30 | 12.43 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 2471.69 | 4.12 | 01-JAN-19:00 | 2.80 | -0.3 | 77895344.68 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 9386816.98 | 251.66 | 27-FEB-17:12 | 11.27 | 4.96 | 70361314.18 | 42.51 | 10-FEB-22:49 | 11.27 | 4.96 |
| March | 11663144.74 | 247.29 | 29-MAR-17:04 | 11.42 | 3.32 | 77894709.28 | 42.51 | 05-MAR-06:49 | 11.42 | 3.32 |
| April | 0.110586E+09 | 325.97 | 08-APR-19:30 | 8.60 | 2.11 | 75994359.85 | 47.66 | 07-APR-21:49 | 8.60 | 2.11 |
| May | 0.358267E+09 | 497.25 | 22-MAY-01:30 | 2.50 | 1.85 | 88035168.80 | 70.27 | 31-MAY-20:10 | 19.53 | 8.95 |
| June | 0.928823E+09 | 974.79 | 29-JUN-18:00 | 28.30 | 12.43 | 0.114282E+09 | 70.38 | 21-JUN-04:00 | 28.30 | 12.43 |
| July | 0.156579E+10 | 1263.20 | 17-JUL-18:30 | 35.25 | 16.50 | 0.127760E+09 | 70.39 | 10-JUL-01:49 | 35.25 | 16.50 |
| August | 0.134739E+10 | 1215.63 | 06-AUG-17:30 | 34.15 | 15.38 | 0.126611E+09 | 70.39 | 27-AUG-02:00 | 13.30 | 10.11 |
| September | 0.980208E+09 | 1142.06 | 04-SEP-17:15 | 32.43 | 16.63 | 0.107082E+09 | 70.38 | 25-SEP-22:00 | 16.70 | 10.75 |
| October | 0.675238E+09 | 600.83 | 21-OCT-04:00 | -1.1 | -2.0 | 88688073.14 | 65.28 | 19-OCT-20:10 | -1.1 | -2.0 |
| November | 0.187872E+09 | 407.90 | 05-NOV-21:50 | 5.63 | 1.83 | 75889193.70 | 49.46 | 04-NOV-20:10 | 5.63 | 1.83 |
| December | 2779890.70 | 102.82 | 06-DEC-17:02 | 6.52 | 2.26 | 77895344.66 | 42.51 | 29-DEC-22:00 | -22.2 | -22.6 |
| Annual Sum or Average | 0.617801E+10 | 0.110839E+10 | ||||||||
| Minimum of Months | 2471.69 | 4.12 | -1.1 | -2.0 | 70361314.18 | 42.51 | -22.2 | -22.6 | ||
| Maximum of Months | 0.156579E+10 | 1263.20 | 35.25 | 16.63 | 0.127760E+09 | 70.39 | 35.25 | 16.50 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.131196E+09 | 538.98 | 15-JAN-17:25 | 0.85 | -2.8 | 78451125.49 | 49.26 | 01-JAN-16:10 | 0.85 | -2.8 |
| February | 0.236704E+09 | 647.90 | 28-FEB-24:00 | -2.7 | -3.8 | 71499786.18 | 66.97 | 26-FEB-17:19 | -2.7 | -3.8 |
| March | 0.319988E+09 | 705.29 | 01-MAR-01:30 | -5.2 | -6.1 | 75730377.85 | 57.78 | 01-MAR-18:10 | 4.53 | 1.66 |
| April | 0.393512E+09 | 476.28 | 08-APR-24:00 | 3.30 | -0.7 | 79528241.56 | 68.80 | 06-APR-17:10 | 3.30 | -0.7 |
| May | 0.565563E+09 | 731.20 | 20-MAY-16:05 | 29.82 | 15.10 | 92237739.94 | 70.38 | 13-MAY-18:00 | 29.82 | 15.10 |
| June | 0.117223E+10 | 1238.17 | 24-JUN-16:10 | 28.22 | 12.89 | 0.113229E+09 | 70.40 | 10-JUN-22:49 | 28.22 | 12.89 |
| July | 0.203399E+10 | 1587.44 | 17-JUL-16:04 | 37.02 | 17.24 | 0.128617E+09 | 70.37 | 30-JUL-05:00 | 16.70 | 10.21 |
| August | 0.205203E+10 | 1736.62 | 10-AUG-15:10 | 33.53 | 14.51 | 0.123071E+09 | 70.37 | 18-AUG-19:00 | 16.10 | 8.79 |
| September | 0.169101E+10 | 1901.38 | 02-SEP-15:10 | 34.32 | 16.28 | 0.116388E+09 | 70.36 | 11-SEP-06:00 | 10.00 | 9.01 |
| October | 0.124192E+10 | 1511.85 | 18-OCT-15:10 | 24.90 | 11.51 | 0.108290E+09 | 70.38 | 02-OCT-20:40 | 24.90 | 11.51 |
| November | 0.755173E+09 | 763.30 | 11-NOV-09:40 | -7.3 | -8.3 | 83826638.38 | 70.39 | 04-NOV-19:30 | -7.3 | -8.3 |
| December | 0.206420E+09 | 638.20 | 12-DEC-13:00 | -2.8 | -5.6 | 78239106.24 | 44.14 | 10-DEC-16:10 | -2.8 | -5.6 |
| Annual Sum or Average | 0.107997E+11 | 0.114911E+10 | ||||||||
| Minimum of Months | 0.131196E+09 | 476.28 | -7.3 | -8.3 | 71499786.18 | 44.14 | -7.3 | -8.3 | ||
| Maximum of Months | 0.205203E+10 | 1901.38 | 37.02 | 17.24 | 0.128617E+09 | 70.40 | 29.82 | 15.10 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 96778711.51 | 516.68 | 01-JAN-20:00 | 1.70 | -1.0 | 78361778.81 | 47.58 | 01-JAN-16:10 | 1.70 | -1.0 |
| February | 0.204702E+09 | 646.15 | 28-FEB-24:00 | -2.7 | -3.8 | 71227661.54 | 65.66 | 26-FEB-17:19 | -2.7 | -3.8 |
| March | 0.283975E+09 | 689.90 | 01-MAR-01:10 | -4.6 | -5.5 | 75595759.92 | 57.52 | 01-MAR-18:10 | 4.53 | 1.66 |
| April | 0.375319E+09 | 477.74 | 08-APR-24:00 | 3.30 | -0.7 | 79377565.06 | 68.75 | 06-APR-17:10 | 3.30 | -0.7 |
| May | 0.570687E+09 | 786.53 | 20-MAY-16:10 | 29.82 | 15.10 | 92661773.53 | 70.36 | 31-MAY-23:40 | 15.70 | 10.35 |
| June | 0.126499E+10 | 1340.17 | 24-JUN-16:10 | 28.22 | 12.89 | 0.114059E+09 | 70.38 | 06-JUN-05:49 | 28.22 | 12.89 |
| July | 0.223748E+10 | 1683.85 | 17-JUL-16:04 | 37.02 | 17.24 | 0.128774E+09 | 70.38 | 12-JUL-01:00 | 37.02 | 17.24 |
| August | 0.223900E+10 | 1817.10 | 10-AUG-15:10 | 33.53 | 14.51 | 0.123314E+09 | 70.37 | 24-AUG-05:40 | 9.43 | 6.50 |
| September | 0.182267E+10 | 2022.59 | 02-SEP-15:10 | 34.32 | 16.28 | 0.117158E+09 | 70.38 | 22-SEP-21:10 | 12.43 | 7.04 |
| October | 0.126997E+10 | 1550.90 | 18-OCT-15:10 | 24.90 | 11.51 | 0.108869E+09 | 70.38 | 22-OCT-22:30 | 9.15 | 4.08 |
| November | 0.735679E+09 | 768.51 | 11-NOV-09:30 | -7.5 | -8.5 | 84098861.31 | 70.34 | 05-NOV-17:10 | -7.5 | -8.5 |
| December | 0.161681E+09 | 628.07 | 12-DEC-14:40 | -2.4 | -5.4 | 78211021.08 | 42.92 | 10-DEC-16:10 | -2.4 | -5.4 |
| Annual Sum or Average | 0.112629E+11 | 0.115171E+10 | ||||||||
| Minimum of Months | 96778711.51 | 477.74 | -7.5 | -8.5 | 71227661.54 | 42.92 | -7.5 | -8.5 | ||
| Maximum of Months | 0.223900E+10 | 2022.59 | 37.02 | 17.24 | 0.128774E+09 | 70.38 | 37.02 | 17.24 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.170758E+09 | 879.91 | 28-JAN-15:00 | -19.4 | -20.2 | 78952897.18 | 55.64 | 14-JAN-16:10 | -19.4 | -20.2 |
| February | 0.368954E+09 | 1297.23 | 26-FEB-17:03 | 14.85 | 5.64 | 73760580.61 | 70.27 | 26-FEB-16:19 | 14.85 | 5.64 |
| March | 0.599473E+09 | 1088.75 | 01-MAR-16:20 | 8.87 | 3.63 | 79506259.31 | 70.27 | 28-MAR-17:10 | 10.32 | 2.85 |
| April | 0.960553E+09 | 1723.97 | 06-APR-16:20 | 21.83 | 10.83 | 93107764.62 | 70.30 | 23-APR-18:19 | 16.13 | 9.01 |
| May | 0.131225E+10 | 2411.40 | 19-MAY-17:30 | 25.85 | 14.38 | 0.105534E+09 | 70.33 | 17-MAY-22:00 | 25.85 | 14.38 |
| June | 0.225562E+10 | 2519.74 | 28-JUN-17:40 | 30.20 | 13.56 | 0.116992E+09 | 70.32 | 11-JUN-00:40 | 30.20 | 13.56 |
| July | 0.313388E+10 | 2916.29 | 17-JUL-16:17 | 36.83 | 17.19 | 0.128749E+09 | 70.32 | 08-JUL-23:30 | 36.83 | 17.19 |
| August | 0.291062E+10 | 2944.42 | 10-AUG-16:30 | 31.95 | 13.64 | 0.122686E+09 | 70.32 | 14-AUG-06:10 | 11.88 | 9.87 |
| September | 0.204546E+10 | 3087.79 | 02-SEP-15:20 | 34.23 | 16.29 | 0.113971E+09 | 70.32 | 15-SEP-20:49 | 8.48 | 5.64 |
| October | 0.125208E+10 | 2435.30 | 18-OCT-15:30 | 24.70 | 11.32 | 0.103817E+09 | 70.33 | 28-OCT-22:19 | 11.50 | 6.31 |
| November | 0.603807E+09 | 852.65 | 03-NOV-15:30 | 14.45 | 7.69 | 82033981.85 | 70.30 | 04-NOV-19:30 | 13.70 | 6.57 |
| December | 0.170417E+09 | 695.34 | 12-DEC-16:10 | -4.8 | -6.5 | 78284742.11 | 48.50 | 10-DEC-16:10 | -4.8 | -6.5 |
| Annual Sum or Average | 0.157839E+11 | 0.117740E+10 | ||||||||
| Minimum of Months | 0.170417E+09 | 695.34 | -19.4 | -20.2 | 73760580.61 | 48.50 | -19.4 | -20.2 | ||
| Maximum of Months | 0.313388E+10 | 3087.79 | 36.83 | 17.19 | 0.128749E+09 | 70.33 | 36.83 | 17.19 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 2831632.90 | 211.95 | 14-JAN-16:10 | 9.82 | 4.49 | 77895344.66 | 42.51 | 11-JAN-22:49 | 9.82 | 4.49 |
| February | 60233405.99 | 472.45 | 27-FEB-21:00 | 3.30 | 0.43 | 70645579.09 | 45.60 | 26-FEB-18:10 | 3.30 | 0.43 |
| March | 0.159983E+09 | 503.02 | 01-MAR-19:00 | 2.20 | 0.36 | 78437853.17 | 46.57 | 22-MAR-17:19 | 10.73 | 4.15 |
| April | 0.551740E+09 | 710.40 | 25-APR-18:40 | 15.33 | 7.27 | 84898764.03 | 70.27 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.997452E+09 | 2010.02 | 19-MAY-17:40 | 25.77 | 14.35 | 0.103189E+09 | 70.30 | 21-MAY-03:20 | 12.03 | 9.57 |
| June | 0.194366E+10 | 2392.41 | 28-JUN-18:00 | 30.00 | 13.45 | 0.120880E+09 | 70.32 | 26-JUN-22:19 | 30.00 | 13.45 |
| July | 0.263290E+10 | 2616.03 | 17-JUL-17:50 | 36.10 | 16.71 | 0.128195E+09 | 70.31 | 12-JUL-02:49 | 36.10 | 16.71 |
| August | 0.215345E+10 | 2420.54 | 10-AUG-17:30 | 31.65 | 13.18 | 0.126774E+09 | 70.32 | 15-AUG-04:40 | 14.47 | 9.08 |
| September | 0.125584E+10 | 2154.47 | 04-SEP-16:40 | 32.80 | 16.68 | 0.107623E+09 | 70.32 | 09-SEP-00:30 | 12.25 | 7.65 |
| October | 0.592248E+09 | 747.24 | 18-OCT-16:08 | 23.95 | 10.92 | 90303491.54 | 69.55 | 19-OCT-20:10 | 12.12 | 5.88 |
| November | 0.147391E+09 | 421.89 | 05-NOV-22:10 | 5.15 | 1.49 | 76026306.05 | 50.73 | 04-NOV-20:10 | 5.15 | 1.49 |
| December | 832031.49 | 90.89 | 06-DEC-17:02 | 6.52 | 2.26 | 77895344.65 | 42.51 | 03-DEC-22:49 | 6.52 | 2.26 |
| Annual Sum or Average | 0.104986E+11 | 0.114276E+10 | ||||||||
| Minimum of Months | 832031.49 | 90.89 | 2.20 | 0.36 | 70645579.09 | 42.51 | 3.30 | 0.43 | ||
| Maximum of Months | 0.263290E+10 | 2616.03 | 36.10 | 16.71 | 0.128195E+09 | 70.32 | 36.10 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.175020E+09 | 685.03 | 28-JAN-14:30 | -19.4 | -20.3 | 79035545.84 | 54.89 | 15-JAN-16:10 | -19.4 | -20.3 |
| February | 0.374025E+09 | 1090.33 | 26-FEB-13:50 | 15.50 | 5.72 | 73800154.33 | 70.27 | 26-FEB-16:19 | 15.93 | 6.13 |
| March | 0.626049E+09 | 835.25 | 01-MAR-04:10 | -9.9 | -10.6 | 79167291.98 | 68.19 | 01-MAR-18:10 | 4.53 | 1.66 |
| April | 0.979900E+09 | 1463.09 | 25-APR-12:20 | 15.57 | 6.75 | 93244067.22 | 70.30 | 12-APR-19:30 | 15.57 | 6.75 |
| May | 0.126929E+10 | 2042.47 | 19-MAY-14:10 | 27.38 | 15.01 | 0.104628E+09 | 70.32 | 11-MAY-18:30 | 27.38 | 15.01 |
| June | 0.235081E+10 | 2254.60 | 29-JUN-14:30 | 31.95 | 14.68 | 0.117045E+09 | 70.32 | 17-JUN-23:40 | 31.95 | 14.68 |
| July | 0.325819E+10 | 2646.36 | 25-JUL-13:00 | 33.90 | 15.43 | 0.128700E+09 | 70.31 | 16-JUL-23:49 | 33.90 | 15.43 |
| August | 0.302490E+10 | 2732.67 | 10-AUG-13:00 | 32.20 | 13.79 | 0.122756E+09 | 70.32 | 03-AUG-02:30 | 32.20 | 13.79 |
| September | 0.205506E+10 | 2879.74 | 02-SEP-14:00 | 33.90 | 16.00 | 0.114190E+09 | 70.33 | 14-SEP-20:40 | 12.03 | 9.07 |
| October | 0.125265E+10 | 2153.41 | 18-OCT-14:10 | 25.00 | 11.44 | 0.103714E+09 | 70.33 | 01-OCT-16:40 | 25.00 | 11.44 |
| November | 0.601672E+09 | 779.75 | 11-NOV-09:10 | -7.9 | -8.8 | 81744439.42 | 70.28 | 04-NOV-18:40 | -7.9 | -8.8 |
| December | 0.171795E+09 | 689.17 | 12-DEC-11:10 | -4.6 | -6.9 | 78262619.31 | 45.16 | 10-DEC-16:10 | -4.6 | -6.9 |
| Annual Sum or Average | 0.161394E+11 | 0.117629E+10 | ||||||||
| Minimum of Months | 0.171795E+09 | 685.03 | -19.4 | -20.3 | 73800154.33 | 45.16 | -19.4 | -20.3 | ||
| Maximum of Months | 0.325819E+10 | 2879.74 | 33.90 | 16.00 | 0.128700E+09 | 70.33 | 33.90 | 15.43 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 2111677.01 | 122.38 | 14-JAN-16:10 | 9.82 | 4.49 | 77895344.67 | 42.51 | 11-JAN-22:49 | 9.82 | 4.49 |
| February | 62110385.60 | 472.07 | 27-FEB-21:00 | 3.30 | 0.43 | 70535865.07 | 42.51 | 10-FEB-22:49 | 3.30 | 0.43 |
| March | 0.172019E+09 | 482.34 | 23-MAR-19:20 | 2.93 | -0.7 | 78201829.47 | 42.98 | 27-MAR-20:10 | 4.50 | -0.4 |
| April | 0.563999E+09 | 575.77 | 13-APR-00:50 | -0.4 | -1.7 | 85049820.53 | 70.27 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.955982E+09 | 1498.85 | 20-MAY-16:05 | 29.82 | 15.10 | 0.102587E+09 | 70.31 | 30-MAY-23:19 | 12.77 | 8.08 |
| June | 0.203465E+10 | 1857.68 | 23-JUN-09:30 | 26.70 | 15.51 | 0.120950E+09 | 70.32 | 04-JUN-23:40 | 26.70 | 15.51 |
| July | 0.275660E+10 | 2027.43 | 17-JUL-16:03 | 37.02 | 17.24 | 0.128087E+09 | 70.31 | 16-JUL-23:49 | 37.02 | 17.24 |
| August | 0.226048E+10 | 1959.06 | 06-AUG-17:30 | 34.15 | 15.38 | 0.126971E+09 | 70.31 | 31-AUG-05:40 | 16.30 | 10.50 |
| September | 0.125115E+10 | 1749.41 | 03-SEP-16:20 | 32.93 | 15.91 | 0.107807E+09 | 70.32 | 23-SEP-20:19 | 14.63 | 9.20 |
| October | 0.589417E+09 | 595.56 | 21-OCT-08:00 | -1.1 | -2.0 | 89761217.86 | 70.15 | 19-OCT-20:10 | -1.1 | -2.0 |
| November | 0.141050E+09 | 414.55 | 05-NOV-22:00 | 5.40 | 1.67 | 75833397.38 | 49.16 | 04-NOV-20:10 | 5.40 | 1.67 |
| December | 380510.96 | 76.58 | 09-DEC-21:00 | 11.70 | 4.42 | 77895344.65 | 42.51 | 03-DEC-22:49 | 11.70 | 4.42 |
| Annual Sum or Average | 0.107900E+11 | 0.114158E+10 | ||||||||
| Minimum of Months | 380510.96 | 76.58 | -1.1 | -2.0 | 70535865.07 | 42.51 | -1.1 | -2.0 | ||
| Maximum of Months | 0.275660E+10 | 2027.43 | 37.02 | 17.24 | 0.128087E+09 | 70.32 | 37.02 | 17.24 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 41236369.12 | 342.28 | 01-JAN-19:00 | 2.80 | -0.3 | 77895332.19 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 0.130438E+09 | 542.29 | 27-FEB-22:35 | 0.77 | -0.9 | 70666435.74 | 45.15 | 27-FEB-21:10 | 0.77 | -0.9 |
| March | 0.355852E+09 | 534.51 | 14-MAR-21:00 | 1.10 | -0.1 | 78405732.49 | 45.95 | 29-MAR-20:10 | 6.52 | 1.11 |
| April | 0.772605E+09 | 618.63 | 27-APR-06:10 | -1.7 | -3.3 | 85892236.54 | 68.57 | 25-APR-20:10 | -1.7 | -3.3 |
| May | 0.100449E+10 | 1201.70 | 20-MAY-17:30 | 26.65 | 14.38 | 0.103939E+09 | 70.32 | 28-MAY-00:20 | 11.13 | 7.81 |
| June | 0.163241E+10 | 1391.54 | 23-JUN-19:00 | 27.20 | 14.36 | 0.122613E+09 | 70.32 | 05-JUN-01:39 | 27.20 | 14.36 |
| July | 0.209859E+10 | 1534.42 | 17-JUL-18:30 | 35.25 | 16.50 | 0.128508E+09 | 70.32 | 10-JUL-03:39 | 35.25 | 16.50 |
| August | 0.178165E+10 | 1465.70 | 06-AUG-18:00 | 33.30 | 15.06 | 0.127936E+09 | 70.32 | 29-AUG-04:00 | 9.40 | 6.61 |
| September | 0.118043E+10 | 1327.45 | 03-SEP-16:30 | 32.20 | 15.70 | 0.110705E+09 | 70.33 | 09-SEP-01:39 | 11.70 | 7.40 |
| October | 0.793698E+09 | 632.66 | 26-OCT-24:00 | -2.2 | -3.9 | 95464333.57 | 70.27 | 19-OCT-20:10 | -2.2 | -3.9 |
| November | 0.339603E+09 | 521.51 | 06-NOV-00:50 | 1.52 | -1.2 | 77007059.80 | 52.76 | 04-NOV-20:10 | 1.52 | -1.2 |
| December | 50677851.88 | 287.14 | 05-DEC-19:00 | 8.90 | 3.89 | 77898851.94 | 43.54 | 09-DEC-21:10 | 11.52 | 4.33 |
| Annual Sum or Average | 0.101817E+11 | 0.115693E+10 | ||||||||
| Minimum of Months | 41236369.12 | 287.14 | -2.2 | -3.9 | 70666435.74 | 42.51 | -2.2 | -3.9 | ||
| Maximum of Months | 0.209859E+10 | 1534.42 | 35.25 | 16.50 | 0.128508E+09 | 70.33 | 35.25 | 16.50 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 41558506.83 | 343.83 | 01-JAN-19:00 | 2.80 | -0.3 | 77895330.25 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 0.130643E+09 | 542.36 | 27-FEB-22:35 | 0.77 | -0.9 | 70663663.85 | 45.17 | 27-FEB-21:10 | 0.77 | -0.9 |
| March | 0.357274E+09 | 534.51 | 14-MAR-21:00 | 1.10 | -0.1 | 78404098.92 | 45.93 | 29-MAR-20:10 | 6.52 | 1.11 |
| April | 0.774686E+09 | 619.36 | 27-APR-06:10 | -1.7 | -3.3 | 86026486.04 | 68.78 | 25-APR-20:10 | -1.7 | -3.3 |
| May | 0.100344E+10 | 1199.38 | 20-MAY-17:30 | 26.65 | 14.38 | 0.103945E+09 | 70.32 | 28-MAY-00:20 | 11.13 | 7.81 |
| June | 0.163835E+10 | 1387.42 | 23-JUN-19:00 | 27.20 | 14.36 | 0.122607E+09 | 70.32 | 09-JUN-22:49 | 27.20 | 14.36 |
| July | 0.210382E+10 | 1525.06 | 17-JUL-18:30 | 35.25 | 16.50 | 0.128500E+09 | 70.32 | 11-JUL-04:49 | 35.25 | 16.50 |
| August | 0.178789E+10 | 1461.97 | 06-AUG-18:00 | 33.30 | 15.06 | 0.127952E+09 | 70.32 | 20-AUG-01:39 | 11.67 | 8.98 |
| September | 0.118259E+10 | 1325.16 | 03-SEP-16:20 | 32.93 | 15.91 | 0.110769E+09 | 70.32 | 29-SEP-20:30 | 10.85 | 6.58 |
| October | 0.793546E+09 | 633.26 | 26-OCT-24:00 | -2.2 | -3.9 | 95473339.81 | 70.30 | 18-OCT-20:49 | -2.2 | -3.9 |
| November | 0.338850E+09 | 516.02 | 06-NOV-00:40 | 1.73 | -1.1 | 76988997.39 | 52.66 | 04-NOV-20:10 | 1.73 | -1.1 |
| December | 50563176.88 | 287.03 | 05-DEC-19:00 | 8.90 | 3.89 | 77898793.56 | 43.53 | 09-DEC-21:10 | 11.52 | 4.33 |
| Annual Sum or Average | 0.102032E+11 | 0.115712E+10 | ||||||||
| Minimum of Months | 41558506.83 | 287.03 | -2.2 | -3.9 | 70663663.85 | 42.51 | -2.2 | -3.9 | ||
| Maximum of Months | 0.210382E+10 | 1525.06 | 35.25 | 16.50 | 0.128500E+09 | 70.32 | 35.25 | 16.50 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.457007E+09 | 1097.45 | 28-JAN-15:10 | -19.5 | -20.3 | 80649416.15 | 62.71 | 01-JAN-16:10 | -19.5 | -20.3 |
| February | 0.680877E+09 | 1261.73 | 28-FEB-14:40 | 10.40 | 4.69 | 76244219.15 | 70.28 | 26-FEB-20:49 | 10.40 | 4.69 |
| March | 0.994395E+09 | 1074.40 | 01-MAR-14:30 | 7.50 | 3.12 | 82980100.42 | 70.27 | 01-MAR-18:10 | 4.53 | 1.66 |
| April | 0.114212E+10 | 1264.36 | 06-APR-16:10 | 22.02 | 10.93 | 98292396.14 | 70.32 | 23-APR-18:10 | 16.42 | 9.07 |
| May | 0.132000E+10 | 1650.89 | 19-MAY-15:10 | 28.22 | 14.82 | 0.107043E+09 | 70.31 | 13-MAY-16:00 | 28.22 | 14.82 |
| June | 0.194966E+10 | 1691.28 | 29-JUN-14:30 | 31.95 | 14.68 | 0.118617E+09 | 70.32 | 07-JUN-02:39 | 31.95 | 14.68 |
| July | 0.260185E+10 | 1989.35 | 25-JUL-15:10 | 34.32 | 15.66 | 0.129052E+09 | 70.31 | 16-JUL-23:49 | 34.32 | 15.66 |
| August | 0.255193E+10 | 2098.94 | 10-AUG-15:10 | 33.53 | 14.51 | 0.123492E+09 | 70.32 | 02-AUG-04:10 | 33.53 | 14.51 |
| September | 0.199056E+10 | 2327.44 | 02-SEP-14:10 | 33.98 | 16.04 | 0.117853E+09 | 70.32 | 30-SEP-01:10 | 9.08 | 5.52 |
| October | 0.150619E+10 | 2082.38 | 18-OCT-14:10 | 25.00 | 11.44 | 0.111540E+09 | 70.32 | 17-OCT-23:40 | 25.00 | 11.44 |
| November | 0.957194E+09 | 1127.76 | 06-NOV-13:40 | 7.87 | 3.05 | 89127158.78 | 70.32 | 05-NOV-19:40 | 7.87 | 3.05 |
| December | 0.523279E+09 | 782.77 | 12-DEC-17:45 | -8.0 | -8.7 | 79092035.26 | 53.18 | 10-DEC-16:10 | -8.0 | -8.7 |
| Annual Sum or Average | 0.166751E+11 | 0.121398E+10 | ||||||||
| Minimum of Months | 0.457007E+09 | 782.77 | -19.5 | -20.3 | 76244219.15 | 53.18 | -19.5 | -20.3 | ||
| Maximum of Months | 0.260185E+10 | 2327.44 | 34.32 | 16.04 | 0.129052E+09 | 70.32 | 34.32 | 15.66 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.458236E+09 | 1097.48 | 28-JAN-15:10 | -19.5 | -20.3 | 80671906.52 | 62.84 | 01-JAN-16:10 | -19.5 | -20.3 |
| February | 0.682143E+09 | 1274.83 | 28-FEB-14:30 | 10.30 | 4.65 | 76252191.78 | 70.28 | 26-FEB-20:49 | 10.30 | 4.65 |
| March | 0.996593E+09 | 1085.41 | 01-MAR-14:30 | 7.50 | 3.12 | 83025912.47 | 70.27 | 01-MAR-18:10 | 4.53 | 1.66 |
| April | 0.114703E+10 | 1274.68 | 06-APR-16:10 | 22.02 | 10.93 | 98352179.82 | 70.32 | 23-APR-17:49 | 16.78 | 9.14 |
| May | 0.132030E+10 | 1652.75 | 19-MAY-15:10 | 28.22 | 14.82 | 0.106996E+09 | 70.32 | 19-MAY-02:30 | 28.22 | 14.82 |
| June | 0.195529E+10 | 1696.36 | 24-JUN-14:00 | 29.40 | 13.85 | 0.118607E+09 | 70.32 | 03-JUN-04:30 | 29.40 | 13.85 |
| July | 0.260704E+10 | 1991.93 | 25-JUL-15:10 | 34.32 | 15.66 | 0.129046E+09 | 70.31 | 16-JUL-23:49 | 34.32 | 15.66 |
| August | 0.255767E+10 | 2104.07 | 10-AUG-14:30 | 33.35 | 14.41 | 0.123496E+09 | 70.32 | 19-AUG-04:10 | 12.80 | 7.43 |
| September | 0.199392E+10 | 2333.18 | 02-SEP-14:10 | 33.98 | 16.04 | 0.117876E+09 | 70.32 | 30-SEP-01:10 | 9.08 | 5.52 |
| October | 0.150877E+10 | 2085.90 | 18-OCT-14:10 | 25.00 | 11.44 | 0.111537E+09 | 70.33 | 25-OCT-04:40 | 14.43 | 8.08 |
| November | 0.956938E+09 | 1137.74 | 06-NOV-13:40 | 7.87 | 3.05 | 89111376.91 | 70.31 | 05-NOV-19:40 | 7.87 | 3.05 |
| December | 0.523356E+09 | 776.99 | 12-DEC-17:35 | -7.8 | -8.6 | 79090078.93 | 53.09 | 10-DEC-16:10 | -7.8 | -8.6 |
| Annual Sum or Average | 0.167073E+11 | 0.121406E+10 | ||||||||
| Minimum of Months | 0.458236E+09 | 776.99 | -19.5 | -20.3 | 76252191.78 | 53.09 | -19.5 | -20.3 | ||
| Maximum of Months | 0.260704E+10 | 2333.18 | 34.32 | 16.04 | 0.129046E+09 | 70.33 | 34.32 | 15.66 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 80698637.09 | 838.25 | 28-JAN-15:00 | -19.4 | -20.2 | 78672218.55 | 60.86 | 14-JAN-16:10 | -19.4 | -20.2 |
| February | 0.250830E+09 | 1933.13 | 26-FEB-17:00 | 15.60 | 5.90 | 72476521.05 | 70.28 | 26-FEB-17:10 | 14.85 | 5.64 |
| March | 0.357556E+09 | 1500.05 | 01-MAR-16:20 | 8.87 | 3.63 | 78623009.72 | 70.29 | 26-MAR-16:40 | 9.23 | 1.62 |
| April | 0.700758E+09 | 2569.63 | 06-APR-16:10 | 22.02 | 10.93 | 86727220.09 | 70.35 | 08-APR-16:49 | 12.80 | 4.62 |
| May | 0.120686E+10 | 3243.51 | 19-MAY-16:07 | 27.52 | 14.54 | 97821198.07 | 70.38 | 28-MAY-22:19 | 13.13 | 7.50 |
| June | 0.220608E+10 | 3336.15 | 30-JUN-17:15 | 29.80 | 14.53 | 0.106795E+09 | 70.37 | 19-JUN-01:30 | 29.80 | 14.53 |
| July | 0.327785E+10 | 4091.77 | 17-JUL-16:04 | 37.02 | 17.24 | 0.123099E+09 | 70.38 | 27-JUL-02:49 | 14.50 | 9.82 |
| August | 0.292123E+10 | 3927.21 | 10-AUG-16:17 | 31.87 | 13.60 | 0.116174E+09 | 70.36 | 01-AUG-03:20 | 31.87 | 13.60 |
| September | 0.182010E+10 | 4122.61 | 02-SEP-15:20 | 34.23 | 16.29 | 0.104821E+09 | 70.37 | 01-SEP-02:00 | 34.23 | 16.29 |
| October | 0.794342E+09 | 2962.93 | 18-OCT-15:20 | 24.80 | 11.42 | 89777916.65 | 70.37 | 18-OCT-22:30 | 15.30 | 7.08 |
| November | 0.296837E+09 | 1506.82 | 03-NOV-15:20 | 14.50 | 7.68 | 77838822.88 | 70.35 | 04-NOV-18:10 | 14.68 | 6.96 |
| December | 75380770.36 | 675.98 | 12-DEC-15:50 | -4.1 | -6.1 | 78236965.09 | 47.86 | 10-DEC-16:10 | -4.1 | -6.1 |
| Annual Sum or Average | 0.139885E+11 | 0.111106E+10 | ||||||||
| Minimum of Months | 75380770.36 | 675.98 | -19.4 | -20.2 | 72476521.05 | 47.86 | -19.4 | -20.2 | ||
| Maximum of Months | 0.327785E+10 | 4122.61 | 37.02 | 17.24 | 0.123099E+09 | 70.38 | 34.23 | 16.29 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 233678.86 | 73.16 | 14-JAN-16:10 | 9.82 | 4.49 | 77895344.64 | 42.51 | 11-JAN-22:49 | 9.82 | 4.49 |
| February | 32075677.19 | 386.49 | 28-FEB-18:25 | 6.65 | 2.69 | 70642955.57 | 50.63 | 26-FEB-18:10 | 6.65 | 2.69 |
| March | 85412504.41 | 471.62 | 02-MAR-18:12 | 3.33 | 0.75 | 78599012.27 | 55.33 | 22-MAR-17:19 | 10.73 | 4.15 |
| April | 0.315642E+09 | 1160.55 | 06-APR-17:30 | 20.55 | 10.15 | 82913931.68 | 70.27 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.885068E+09 | 2747.51 | 19-MAY-17:30 | 25.85 | 14.38 | 97650976.13 | 70.38 | 26-MAY-21:49 | 12.38 | 8.31 |
| June | 0.187689E+10 | 3149.25 | 28-JUN-18:00 | 30.00 | 13.45 | 0.110561E+09 | 70.35 | 26-JUN-02:39 | 30.00 | 13.45 |
| July | 0.274035E+10 | 3616.13 | 17-JUL-17:30 | 36.10 | 16.83 | 0.122810E+09 | 70.38 | 11-JUL-23:49 | 36.10 | 16.83 |
| August | 0.213110E+10 | 3273.53 | 06-AUG-16:30 | 35.30 | 16.02 | 0.119441E+09 | 70.37 | 12-AUG-03:39 | 15.00 | 7.62 |
| September | 0.103612E+10 | 2909.05 | 04-SEP-16:40 | 32.80 | 16.68 | 0.100730E+09 | 70.38 | 01-SEP-01:00 | 32.80 | 16.68 |
| October | 0.224766E+09 | 1110.10 | 18-OCT-16:05 | 23.95 | 10.92 | 83862895.82 | 65.76 | 18-OCT-20:00 | 14.40 | 6.96 |
| November | 37361147.12 | 299.71 | 01-NOV-17:40 | 9.63 | 3.95 | 75586181.49 | 47.47 | 04-NOV-20:10 | 13.27 | 6.37 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 77895344.63 | 42.51 | 03-DEC-22:49 | 0.92 | -2.7 |
| Annual Sum or Average | 0.936501E+10 | 0.109859E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -2.1 | -4.2 | 70642955.57 | 42.51 | 0.92 | -2.7 | ||
| Maximum of Months | 0.274035E+10 | 3616.13 | 36.10 | 16.83 | 0.122810E+09 | 70.38 | 36.10 | 16.83 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 73939087.28 | 599.65 | 31-JAN-12:50 | -1.4 | -4.9 | 78706054.75 | 58.28 | 14-JAN-16:10 | -1.4 | -4.9 |
| February | 0.241951E+09 | 1732.86 | 26-FEB-14:00 | 15.60 | 5.76 | 72360442.40 | 70.34 | 20-FEB-16:00 | 15.60 | 5.76 |
| March | 0.352505E+09 | 1319.93 | 20-MAR-14:30 | 10.00 | 3.25 | 78113539.90 | 70.37 | 14-MAR-17:10 | 10.00 | 3.25 |
| April | 0.701477E+09 | 1981.72 | 06-APR-15:10 | 21.28 | 10.55 | 86453087.05 | 70.37 | 06-APR-21:49 | 14.90 | 7.55 |
| May | 0.114082E+10 | 2759.39 | 19-MAY-14:10 | 27.38 | 15.01 | 96973032.61 | 70.38 | 13-MAY-23:40 | 27.38 | 15.01 |
| June | 0.227287E+10 | 3045.17 | 23-JUN-13:30 | 31.40 | 15.21 | 0.107209E+09 | 70.38 | 01-JUN-00:20 | 31.40 | 15.21 |
| July | 0.338457E+10 | 3643.69 | 25-JUL-13:00 | 33.90 | 15.43 | 0.123529E+09 | 70.38 | 27-JUL-02:09 | 14.90 | 10.24 |
| August | 0.301373E+10 | 3679.28 | 10-AUG-13:00 | 32.20 | 13.79 | 0.116251E+09 | 70.39 | 13-AUG-22:40 | 15.00 | 10.58 |
| September | 0.180605E+10 | 3836.20 | 02-SEP-14:00 | 33.90 | 16.00 | 0.104895E+09 | 70.37 | 05-SEP-23:40 | 14.80 | 12.58 |
| October | 0.773047E+09 | 2579.65 | 18-OCT-14:10 | 25.00 | 11.44 | 89579339.79 | 70.37 | 23-OCT-20:10 | 13.03 | 6.25 |
| November | 0.287248E+09 | 1287.94 | 03-NOV-13:50 | 14.78 | 7.82 | 77368488.58 | 70.27 | 03-NOV-17:10 | 13.68 | 7.40 |
| December | 72146419.43 | 647.12 | 12-DEC-13:00 | -2.8 | -5.6 | 78224019.62 | 42.53 | 10-DEC-16:10 | -2.8 | -5.6 |
| Annual Sum or Average | 0.141204E+11 | 0.110966E+10 | ||||||||
| Minimum of Months | 72146419.43 | 599.65 | -2.8 | -5.6 | 72360442.40 | 42.53 | -2.8 | -5.6 | ||
| Maximum of Months | 0.338457E+10 | 3836.20 | 33.90 | 16.00 | 0.123529E+09 | 70.39 | 31.40 | 15.21 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.3 | 77895344.65 | 42.51 | 11-JAN-22:49 | -1.3 | -3.5 |
| February | 21904833.08 | 343.89 | 27-FEB-18:40 | 7.93 | 3.28 | 70468369.53 | 42.51 | 10-FEB-22:49 | 7.93 | 3.28 |
| March | 83223557.10 | 380.34 | 14-MAR-18:00 | 6.70 | 3.17 | 78161870.13 | 44.18 | 14-MAR-17:10 | 6.70 | 3.17 |
| April | 0.303094E+09 | 714.06 | 24-APR-18:50 | 15.47 | 6.66 | 82567526.56 | 70.27 | 25-APR-20:40 | 11.87 | 5.15 |
| May | 0.824717E+09 | 1957.30 | 19-MAY-16:07 | 27.52 | 14.54 | 96858739.62 | 70.37 | 29-MAY-23:30 | 15.55 | 10.31 |
| June | 0.193601E+10 | 2417.74 | 29-JUN-15:10 | 32.02 | 14.63 | 0.110978E+09 | 70.37 | 06-JUN-21:49 | 32.02 | 14.63 |
| July | 0.284849E+10 | 2805.40 | 17-JUL-16:07 | 37.02 | 17.24 | 0.122970E+09 | 70.37 | 29-JUL-00:00 | 16.10 | 9.74 |
| August | 0.220805E+10 | 2647.63 | 06-AUG-16:05 | 35.50 | 16.24 | 0.119788E+09 | 70.38 | 23-AUG-22:00 | 15.60 | 9.85 |
| September | 0.100541E+10 | 2290.91 | 03-SEP-16:04 | 33.67 | 16.10 | 0.100390E+09 | 70.38 | 25-SEP-23:40 | 16.70 | 10.58 |
| October | 0.212238E+09 | 579.66 | 18-OCT-16:10 | 23.95 | 10.92 | 82770091.45 | 63.62 | 19-OCT-20:10 | 12.12 | 5.88 |
| November | 24668618.62 | 275.50 | 01-NOV-17:17 | 10.37 | 4.35 | 75443324.46 | 45.02 | 04-NOV-20:10 | 13.27 | 6.37 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 77895344.64 | 42.51 | 03-DEC-22:49 | 0.92 | -2.7 |
| Annual Sum or Average | 0.946780E+10 | 0.109619E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -2.1 | -4.2 | 70468369.53 | 42.51 | -1.3 | -3.5 | ||
| Maximum of Months | 0.284849E+10 | 2805.40 | 37.02 | 17.24 | 0.122970E+09 | 70.38 | 32.02 | 14.63 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 668998.03 | 100.20 | 14-JAN-16:10 | 9.82 | 4.49 | 77895344.66 | 42.51 | 11-JAN-22:49 | 9.82 | 4.49 |
| February | 34446839.95 | 394.83 | 27-FEB-19:30 | 6.10 | 2.19 | 70489953.65 | 43.44 | 26-FEB-18:10 | 6.10 | 2.19 |
| March | 0.102730E+09 | 419.54 | 14-MAR-18:25 | 5.30 | 2.59 | 78239847.12 | 46.24 | 14-MAR-17:10 | 5.30 | 2.59 |
| April | 0.326675E+09 | 515.41 | 25-APR-18:50 | 14.87 | 7.13 | 82646301.97 | 70.27 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.749796E+09 | 1558.77 | 20-MAY-16:05 | 29.82 | 15.10 | 98628760.20 | 70.35 | 20-MAY-01:00 | 29.82 | 15.10 |
| June | 0.153077E+10 | 1856.47 | 29-JUN-16:04 | 30.63 | 14.01 | 0.113509E+09 | 70.40 | 17-JUN-21:00 | 30.63 | 14.01 |
| July | 0.216667E+10 | 2187.19 | 17-JUL-16:04 | 37.02 | 17.24 | 0.124821E+09 | 70.38 | 27-JUL-05:49 | 13.40 | 10.02 |
| August | 0.171746E+10 | 2053.46 | 06-AUG-16:17 | 35.40 | 16.13 | 0.122030E+09 | 70.38 | 29-AUG-01:30 | 15.00 | 9.93 |
| September | 0.894297E+09 | 1812.27 | 03-SEP-16:20 | 32.93 | 15.91 | 0.102284E+09 | 70.38 | 26-SEP-21:49 | 12.88 | 9.47 |
| October | 0.288432E+09 | 462.26 | 20-OCT-20:20 | 3.70 | 1.45 | 84335646.91 | 66.59 | 19-OCT-20:10 | 3.70 | 1.45 |
| November | 61691991.94 | 348.33 | 05-NOV-20:20 | 7.80 | 3.29 | 75675203.59 | 49.73 | 04-NOV-20:10 | 7.80 | 3.29 |
| December | 13037.44 | 16.64 | 09-DEC-21:00 | 11.70 | 4.42 | 77895344.65 | 42.51 | 03-DEC-22:49 | 11.70 | 4.42 |
| Annual Sum or Average | 0.787365E+10 | 0.110845E+10 | ||||||||
| Minimum of Months | 13037.44 | 16.64 | 3.70 | 1.45 | 70489953.65 | 42.51 | 3.70 | 1.45 | ||
| Maximum of Months | 0.216667E+10 | 2187.19 | 37.02 | 17.24 | 0.124821E+09 | 70.40 | 30.63 | 15.10 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 682071.07 | 98.42 | 14-JAN-16:10 | 9.82 | 4.49 | 77895344.66 | 42.51 | 11-JAN-22:49 | 9.82 | 4.49 |
| February | 33860375.84 | 394.34 | 27-FEB-19:30 | 6.10 | 2.19 | 70483467.44 | 42.92 | 26-FEB-18:10 | 6.10 | 2.19 |
| March | 0.102681E+09 | 419.25 | 14-MAR-18:25 | 5.30 | 2.59 | 78226953.33 | 46.12 | 14-MAR-17:10 | 5.30 | 2.59 |
| April | 0.328878E+09 | 514.49 | 25-APR-18:50 | 14.87 | 7.13 | 82685830.13 | 70.27 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.750817E+09 | 1556.23 | 20-MAY-16:05 | 29.82 | 15.10 | 98595800.86 | 70.36 | 25-MAY-20:30 | 13.05 | 8.84 |
| June | 0.153974E+10 | 1850.43 | 29-JUN-16:04 | 30.63 | 14.01 | 0.113530E+09 | 70.37 | 25-JUN-00:30 | 30.63 | 14.01 |
| July | 0.217549E+10 | 2177.32 | 17-JUL-16:04 | 37.02 | 17.24 | 0.124799E+09 | 70.39 | 31-JUL-03:39 | 15.60 | 9.80 |
| August | 0.172692E+10 | 2045.23 | 06-AUG-16:17 | 35.40 | 16.13 | 0.122040E+09 | 70.38 | 05-AUG-03:00 | 35.40 | 16.13 |
| September | 0.896362E+09 | 1803.46 | 03-SEP-16:20 | 32.93 | 15.91 | 0.102286E+09 | 70.39 | 24-SEP-22:30 | 15.85 | 9.94 |
| October | 0.287876E+09 | 461.96 | 20-OCT-20:20 | 3.70 | 1.45 | 84252321.03 | 66.79 | 19-OCT-20:10 | 3.70 | 1.45 |
| November | 61029217.86 | 347.97 | 05-NOV-20:20 | 7.80 | 3.29 | 75662390.06 | 49.47 | 04-NOV-20:10 | 7.80 | 3.29 |
| December | 12344.69 | 16.33 | 09-DEC-21:00 | 11.70 | 4.42 | 77895344.65 | 42.51 | 03-DEC-22:49 | 11.70 | 4.42 |
| Annual Sum or Average | 0.790435E+10 | 0.110835E+10 | ||||||||
| Minimum of Months | 12344.69 | 16.33 | 3.70 | 1.45 | 70483467.44 | 42.51 | 3.70 | 1.45 | ||
| Maximum of Months | 0.217549E+10 | 2177.32 | 37.02 | 17.24 | 0.124799E+09 | 70.39 | 35.40 | 16.13 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.166121E+09 | 1093.59 | 28-JAN-14:50 | -19.4 | -20.3 | 79248054.07 | 64.21 | 15-JAN-16:10 | -19.4 | -20.3 |
| February | 0.357536E+09 | 1695.46 | 26-FEB-14:00 | 15.60 | 5.76 | 73544017.31 | 70.36 | 25-FEB-18:49 | 15.60 | 5.76 |
| March | 0.459531E+09 | 1250.37 | 20-MAR-15:10 | 10.00 | 3.20 | 79568656.22 | 70.36 | 26-MAR-17:10 | 9.32 | 1.63 |
| April | 0.715180E+09 | 1710.11 | 06-APR-16:10 | 22.02 | 10.93 | 88600188.37 | 70.37 | 13-APR-18:49 | 10.47 | 5.48 |
| May | 0.106021E+10 | 2256.18 | 19-MAY-15:10 | 28.22 | 14.82 | 0.100064E+09 | 70.36 | 09-MAY-17:00 | 28.22 | 14.82 |
| June | 0.186275E+10 | 2369.10 | 24-JUN-14:00 | 29.40 | 13.85 | 0.109702E+09 | 70.36 | 17-JUN-20:40 | 29.40 | 13.85 |
| July | 0.270784E+10 | 2860.96 | 25-JUL-14:30 | 34.15 | 15.57 | 0.125210E+09 | 70.38 | 13-JUL-01:30 | 34.15 | 15.57 |
| August | 0.252140E+10 | 2958.24 | 09-AUG-13:40 | 33.70 | 16.29 | 0.118715E+09 | 70.38 | 30-AUG-02:00 | 13.90 | 8.81 |
| September | 0.169659E+10 | 3194.60 | 02-SEP-14:00 | 33.90 | 16.00 | 0.107843E+09 | 70.38 | 26-SEP-03:30 | 14.15 | 9.56 |
| October | 0.931834E+09 | 2370.86 | 18-OCT-14:20 | 25.00 | 11.47 | 93520486.32 | 70.38 | 28-OCT-21:49 | 12.62 | 6.88 |
| November | 0.432946E+09 | 1372.03 | 03-NOV-14:10 | 14.93 | 7.82 | 79738008.70 | 70.33 | 13-NOV-16:30 | 3.15 | -2.5 |
| December | 0.165344E+09 | 709.45 | 12-DEC-16:20 | -5.2 | -6.8 | 78407471.07 | 52.43 | 10-DEC-16:10 | -5.2 | -6.8 |
| Annual Sum or Average | 0.130773E+11 | 0.113416E+10 | ||||||||
| Minimum of Months | 0.165344E+09 | 709.45 | -19.4 | -20.3 | 73544017.31 | 52.43 | -19.4 | -20.3 | ||
| Maximum of Months | 0.270784E+10 | 3194.60 | 34.15 | 16.29 | 0.125210E+09 | 70.38 | 34.15 | 15.57 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.166764E+09 | 1093.59 | 28-JAN-14:50 | -19.4 | -20.3 | 79252894.14 | 64.35 | 15-JAN-16:10 | -19.4 | -20.3 |
| February | 0.359505E+09 | 1717.39 | 26-FEB-14:00 | 15.60 | 5.76 | 73530640.53 | 70.32 | 25-FEB-18:49 | 15.60 | 5.76 |
| March | 0.463042E+09 | 1262.64 | 20-MAR-15:10 | 10.00 | 3.20 | 79543926.93 | 70.37 | 26-MAR-17:10 | 9.32 | 1.63 |
| April | 0.721438E+09 | 1710.93 | 06-APR-15:20 | 21.47 | 10.64 | 88587258.94 | 70.39 | 23-APR-21:10 | 12.02 | 7.93 |
| May | 0.106269E+10 | 2262.56 | 19-MAY-15:10 | 28.22 | 14.82 | 99981350.72 | 70.39 | 20-MAY-02:30 | 14.70 | 10.01 |
| June | 0.187249E+10 | 2382.46 | 24-JUN-14:00 | 29.40 | 13.85 | 0.109692E+09 | 70.39 | 01-JUN-01:00 | 29.40 | 13.85 |
| July | 0.271708E+10 | 2868.80 | 25-JUL-14:20 | 34.07 | 15.53 | 0.125198E+09 | 70.39 | 30-JUL-03:49 | 15.60 | 9.71 |
| August | 0.253084E+10 | 2971.37 | 09-AUG-13:40 | 33.70 | 16.29 | 0.118700E+09 | 70.38 | 30-AUG-03:09 | 13.43 | 8.58 |
| September | 0.170128E+10 | 3205.62 | 02-SEP-14:00 | 33.90 | 16.00 | 0.107836E+09 | 70.37 | 26-SEP-03:39 | 14.07 | 9.58 |
| October | 0.934939E+09 | 2379.74 | 18-OCT-14:10 | 25.00 | 11.44 | 93502355.46 | 70.38 | 28-OCT-21:49 | 12.62 | 6.88 |
| November | 0.433119E+09 | 1385.99 | 03-NOV-14:10 | 14.93 | 7.82 | 79690947.48 | 70.27 | 03-NOV-17:10 | 13.68 | 7.40 |
| December | 0.165483E+09 | 708.93 | 12-DEC-16:20 | -5.2 | -6.8 | 78406921.07 | 52.21 | 10-DEC-16:10 | -5.2 | -6.8 |
| Annual Sum or Average | 0.131287E+11 | 0.113392E+10 | ||||||||
| Minimum of Months | 0.165483E+09 | 708.93 | -19.4 | -20.3 | 73530640.53 | 52.21 | -19.4 | -20.3 | ||
| Maximum of Months | 0.271708E+10 | 3205.62 | 34.07 | 16.29 | 0.125198E+09 | 70.39 | 29.40 | 13.85 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.3 | 86421222.47 | 78.47 | 14-JAN-21:10 | 8.80 | 3.43 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -12.4 | -13.9 | 98884855.36 | 102.56 | 26-FEB-21:10 | 6.60 | 1.70 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 | -4.1 | 0.123813E+09 | 103.83 | 28-MAR-20:10 | 4.13 | -0.8 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 | 0.55 | 0.155859E+09 | 142.51 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 | -3.0 | 0.194431E+09 | 166.66 | 19-MAY-20:10 | 21.93 | 12.97 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 | 10.36 | 0.240382E+09 | 175.95 | 30-JUN-20:10 | 24.03 | 12.64 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 | 13.32 | 0.273616E+09 | 187.14 | 17-JUL-20:10 | 28.53 | 15.13 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 | 11.96 | 0.262362E+09 | 180.29 | 05-AUG-20:10 | 25.55 | 14.02 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 | 11.59 | 0.212111E+09 | 173.67 | 02-SEP-20:10 | 26.52 | 13.06 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 | 6.94 | 0.163079E+09 | 134.90 | 18-OCT-20:10 | 15.82 | 7.55 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 | 1.54 | 0.118076E+09 | 105.69 | 04-NOV-20:10 | 13.27 | 6.37 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 95529276.68 | 71.70 | 10-DEC-03:00 | 12.20 | 4.79 |
| Annual Sum or Average | 0.00 | 0.202456E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -12.4 | -13.9 | 86421222.47 | 71.70 | 4.13 | -0.8 | ||
| Maximum of Months | 0.00 | 0.00 | 19.45 | 13.32 | 0.273616E+09 | 187.14 | 28.53 | 15.13 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.3 | 43760352.60 | 63.57 | 02-JAN-05:40 | -0.7 | -3.0 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -12.4 | -13.9 | 54475745.21 | 78.17 | 28-FEB-00:30 | 0.55 | -1.1 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 | -4.1 | 71612867.47 | 73.94 | 01-MAR-00:49 | -4.0 | -5.0 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 | 0.55 | 98577269.42 | 95.98 | 07-APR-21:49 | 15.18 | 6.20 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 | -3.0 | 0.137445E+09 | 150.41 | 20-MAY-17:10 | 28.15 | 14.50 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 | 10.36 | 0.218643E+09 | 175.67 | 28-JUN-17:10 | 30.50 | 13.74 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 | 13.32 | 0.276725E+09 | 232.59 | 17-JUL-17:10 | 36.10 | 16.94 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 | 11.96 | 0.262649E+09 | 222.00 | 06-AUG-17:10 | 34.72 | 15.59 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 | 11.59 | 0.208328E+09 | 214.00 | 02-SEP-17:10 | 34.03 | 16.47 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 | 6.94 | 0.151189E+09 | 131.34 | 01-OCT-00:10 | 11.57 | 6.94 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 | 1.54 | 92386268.14 | 99.07 | 05-NOV-05:10 | 7.27 | 2.86 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 56055759.55 | 67.16 | 07-DEC-05:49 | -1.2 | -2.6 |
| Annual Sum or Average | 0.00 | 0.167185E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -12.4 | -13.9 | 43760352.60 | 63.57 | -4.0 | -5.0 | ||
| Maximum of Months | 0.00 | 0.00 | 19.45 | 13.32 | 0.276725E+09 | 232.59 | 36.10 | 16.94 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 | -1.3 | 0.132950E+09 | 95.31 | 01-JAN-21:10 | 2.12 | -0.6 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -12.4 | -13.9 | 0.135762E+09 | 113.80 | 27-FEB-21:10 | 2.93 | 0.23 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 | -4.1 | 0.163158E+09 | 107.83 | 01-MAR-21:10 | 1.97 | -0.3 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 | 0.55 | 0.190079E+09 | 141.34 | 25-APR-20:10 | 12.12 | 5.45 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 | -3.0 | 0.220828E+09 | 157.02 | 20-MAY-20:10 | 19.63 | 12.03 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 | 10.36 | 0.263231E+09 | 164.11 | 23-JUN-20:10 | 23.53 | 14.25 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 | 13.32 | 0.283714E+09 | 168.67 | 17-JUL-20:10 | 28.53 | 15.13 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 | 11.96 | 0.278265E+09 | 166.03 | 07-AUG-20:10 | 25.73 | 13.51 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 | 11.59 | 0.239958E+09 | 163.23 | 02-SEP-20:10 | 26.52 | 13.06 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 | 6.94 | 0.209759E+09 | 141.90 | 19-OCT-20:10 | 12.12 | 5.88 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 | 1.54 | 0.160032E+09 | 114.68 | 05-NOV-20:10 | 8.05 | 3.46 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 | -4.2 | 0.139327E+09 | 88.10 | 06-DEC-21:10 | -0.7 | -2.6 |
| Annual Sum or Average | 0.00 | 0.241706E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -12.4 | -13.9 | 0.132950E+09 | 88.10 | -0.7 | -2.6 | ||
| Maximum of Months | 0.00 | 0.00 | 19.45 | 13.32 | 0.283714E+09 | 168.67 | 28.53 | 15.13 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.262794E+10 | 2754.62 | 11-JAN-08:13 | -15.7 |
| February | 0.141814E+10 | 1974.51 | 04-FEB-08:10 | -20.0 |
| March | 0.113721E+10 | 1922.11 | 06-MAR-04:00 | -18.3 |
| April | 0.506639E+09 | 1152.98 | 29-APR-05:00 | -7.8 |
| May | 0.256823E+09 | 1007.32 | 08-MAY-08:00 | -1.7 |
| June | 3465.57 | 5.78 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 8327.56 | 12.79 | 20-SEP-06:00 | 3.30 |
| October | 24142202.27 | 464.68 | 10-OCT-06:50 | -6.1 |
| November | 0.480793E+09 | 1316.27 | 27-NOV-05:00 | -15.6 |
| December | 0.160202E+10 | 2306.73 | 31-DEC-08:20 | -27.4 |
| Annual Sum or Average | 0.805372E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.262794E+10 | 2754.62 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.354327E+10 | 2802.66 | 11-JAN-08:13 | -15.7 |
| February | 0.226265E+10 | 2144.16 | 04-FEB-08:13 | -20.0 |
| March | 0.190691E+10 | 2095.46 | 06-MAR-04:00 | -18.3 |
| April | 0.875911E+09 | 1222.39 | 29-APR-05:00 | -7.8 |
| May | 0.356363E+09 | 1056.78 | 08-MAY-08:00 | -1.7 |
| June | 259374.83 | 64.24 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 14342197.32 | 276.85 | 20-SEP-04:00 | 3.30 |
| October | 0.103761E+09 | 641.16 | 10-OCT-07:20 | -5.4 |
| November | 0.968072E+09 | 1537.42 | 27-NOV-05:00 | -15.6 |
| December | 0.244777E+10 | 2432.10 | 31-DEC-08:14 | -27.4 |
| Annual Sum or Average | 0.124793E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.354327E+10 | 2802.66 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.163808E+10 | 10005.12 | 12-JAN-07:01 | 5.68 |
| February | 0.769261E+09 | 9865.84 | 13-FEB-07:01 | 2.80 |
| March | 0.498316E+09 | 9870.79 | 09-MAR-07:01 | 2.80 |
| April | 0.182235E+09 | 9789.77 | 20-APR-07:01 | 2.38 |
| May | 0.276774E+09 | 9786.08 | 01-MAY-06:01 | 0.10 |
| June | 0.215526E+09 | 631.30 | 28-JUN-16:12 | 30.93 |
| July | 0.288499E+09 | 750.26 | 17-JUL-16:13 | 36.83 |
| August | 0.208054E+09 | 637.15 | 04-AUG-16:12 | 31.10 |
| September | 0.114662E+09 | 494.43 | 01-SEP-16:13 | 28.13 |
| October | 43371411.28 | 9472.74 | 10-OCT-07:01 | -5.7 |
| November | 0.289363E+09 | 9765.57 | 30-NOV-08:61 | 1.10 |
| December | 0.790734E+09 | 9830.22 | 05-DEC-08:61 | 6.28 |
| Annual Sum or Average | 0.531488E+10 | |||
| Minimum of Months | 43371411.28 | 494.43 | -5.7 | |
| Maximum of Months | 0.163808E+10 | 10005.12 | 36.83 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.349778E+10 | 2795.22 | 11-JAN-08:10 | -17.3 |
| February | 0.223965E+10 | 2132.10 | 04-FEB-08:13 | -20.0 |
| March | 0.185153E+10 | 2091.27 | 06-MAR-04:00 | -18.3 |
| April | 0.839038E+09 | 1259.26 | 29-APR-05:00 | -7.8 |
| May | 0.354482E+09 | 1046.39 | 08-MAY-08:00 | -1.7 |
| June | 429637.30 | 90.37 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 12049416.54 | 282.50 | 20-SEP-04:00 | 3.30 |
| October | 92089815.12 | 583.22 | 10-OCT-06:50 | -6.1 |
| November | 0.967822E+09 | 1530.70 | 27-NOV-05:00 | -15.6 |
| December | 0.243292E+10 | 2420.95 | 31-DEC-08:20 | -27.4 |
| Annual Sum or Average | 0.122878E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.349778E+10 | 2795.22 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.197186E+10 | 1769.00 | 11-JAN-08:13 | -15.7 |
| February | 0.119632E+10 | 1316.06 | 04-FEB-08:13 | -20.0 |
| March | 0.893002E+09 | 1255.40 | 06-MAR-08:18 | -15.5 |
| April | 0.300967E+09 | 623.63 | 29-APR-05:00 | -7.8 |
| May | 0.115249E+09 | 502.26 | 08-MAY-08:00 | -1.7 |
| June | 237741.45 | 45.04 | 18-JUN-15:50 | 24.90 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 320126.71 | 150.64 | 21-SEP-10:05 | 15.78 |
| October | 13427272.17 | 234.45 | 12-OCT-09:40 | 15.93 |
| November | 0.365077E+09 | 812.15 | 27-NOV-05:00 | -15.6 |
| December | 0.122168E+10 | 1518.68 | 31-DEC-08:20 | -27.4 |
| Annual Sum or Average | 0.607814E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.197186E+10 | 1769.00 | 24.90 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.196998E+10 | 1769.07 | 11-JAN-08:13 | -15.7 |
| February | 0.119559E+10 | 1316.19 | 04-FEB-08:13 | -20.0 |
| March | 0.890836E+09 | 1250.82 | 06-MAR-08:18 | -15.5 |
| April | 0.300325E+09 | 625.27 | 29-APR-05:00 | -7.8 |
| May | 0.115683E+09 | 501.80 | 08-MAY-08:00 | -1.7 |
| June | 223610.35 | 42.34 | 18-JUN-15:40 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 289017.78 | 178.75 | 21-SEP-10:05 | 15.78 |
| October | 13264644.65 | 236.87 | 12-OCT-09:40 | 15.93 |
| November | 0.365517E+09 | 811.91 | 27-NOV-05:00 | -15.6 |
| December | 0.122132E+10 | 1518.46 | 31-DEC-08:20 | -27.4 |
| Annual Sum or Average | 0.607302E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.196998E+10 | 1769.07 | 24.80 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.118144E+10 | 1719.96 | 11-JAN-08:15 | -15.7 |
| February | 0.517533E+09 | 1129.56 | 04-FEB-08:16 | -20.0 |
| March | 0.330975E+09 | 1048.45 | 06-MAR-04:00 | -18.3 |
| April | 0.102210E+09 | 535.11 | 29-APR-05:00 | -7.8 |
| May | 67757668.52 | 460.42 | 09-MAY-05:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 137391.10 | 43.21 | 10-OCT-06:50 | -6.1 |
| November | 0.139312E+09 | 607.61 | 28-NOV-08:20 | -4.3 |
| December | 0.576581E+09 | 1394.76 | 31-DEC-08:20 | -27.4 |
| Annual Sum or Average | 0.291594E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.118144E+10 | 1719.96 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.139903E+10 | 1857.99 | 11-JAN-08:15 | -15.7 |
| February | 0.663546E+09 | 1277.12 | 05-FEB-07:50 | -20.0 |
| March | 0.435237E+09 | 1226.14 | 06-MAR-04:00 | -18.3 |
| April | 0.131484E+09 | 600.35 | 29-APR-05:00 | -7.8 |
| May | 95339121.56 | 562.80 | 09-MAY-05:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 626591.64 | 83.59 | 10-OCT-06:50 | -6.1 |
| November | 0.179144E+09 | 731.39 | 28-NOV-08:20 | -4.3 |
| December | 0.749638E+09 | 1571.13 | 31-DEC-08:20 | -27.4 |
| Annual Sum or Average | 0.365404E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -27.4 | |
| Maximum of Months | 0.139903E+10 | 1857.99 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.194231E+10 | 2332.96 | 11-JAN-08:12 | -15.7 |
| February | 0.787066E+09 | 1624.00 | 04-FEB-03:00 | -21.7 |
| March | 0.417577E+09 | 1532.65 | 06-MAR-04:00 | -18.3 |
| April | 59268748.50 | 727.59 | 29-APR-05:00 | -7.8 |
| May | 63467937.95 | 666.64 | 08-MAY-05:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 47226.59 | 38.87 | 20-SEP-06:00 | 3.30 |
| October | 23307449.19 | 505.82 | 10-OCT-06:00 | -6.1 |
| November | 0.432412E+09 | 1435.94 | 27-NOV-05:00 | -15.6 |
| December | 0.121900E+10 | 2019.67 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.494446E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -24.4 | |
| Maximum of Months | 0.194231E+10 | 2332.96 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.272649E+10 | 2374.87 | 10-JAN-23:10 | -33.5 |
| February | 0.140147E+10 | 1726.59 | 04-FEB-03:00 | -21.7 |
| March | 0.806671E+09 | 1692.26 | 06-MAR-04:00 | -18.3 |
| April | 0.109321E+09 | 752.61 | 29-APR-05:00 | -7.8 |
| May | 80056137.71 | 714.05 | 08-MAY-05:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 11861919.73 | 276.81 | 20-SEP-04:00 | 3.30 |
| October | 96502219.23 | 590.28 | 10-OCT-09:00 | -2.8 |
| November | 0.830788E+09 | 1638.47 | 27-NOV-05:00 | -15.6 |
| December | 0.194282E+10 | 2148.78 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.800598E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -33.5 | |
| Maximum of Months | 0.272649E+10 | 2374.87 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.189873E+10 | 2326.68 | 11-JAN-08:02 | -17.3 |
| February | 0.777950E+09 | 1621.27 | 04-FEB-03:00 | -21.7 |
| March | 0.402614E+09 | 1527.08 | 06-MAR-04:00 | -18.3 |
| April | 60262870.65 | 753.58 | 29-APR-05:00 | -7.8 |
| May | 63646044.69 | 663.68 | 09-MAY-05:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 121279.61 | 52.69 | 20-SEP-06:00 | 3.30 |
| October | 23234832.57 | 497.50 | 10-OCT-06:00 | -6.1 |
| November | 0.435066E+09 | 1427.98 | 27-NOV-05:00 | -15.6 |
| December | 0.120202E+10 | 2018.24 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.486364E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -24.4 | |
| Maximum of Months | 0.189873E+10 | 2326.68 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.267775E+10 | 2363.38 | 10-JAN-23:10 | -33.5 |
| February | 0.137899E+10 | 1722.70 | 04-FEB-03:00 | -21.7 |
| March | 0.762710E+09 | 1687.28 | 06-MAR-04:00 | -18.3 |
| April | 0.107393E+09 | 779.03 | 29-APR-05:00 | -7.8 |
| May | 85076384.05 | 703.01 | 08-MAY-05:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 10476462.23 | 304.26 | 20-SEP-04:00 | 3.30 |
| October | 81077564.64 | 577.67 | 10-OCT-06:00 | -6.1 |
| November | 0.826356E+09 | 1633.86 | 27-NOV-05:00 | -15.6 |
| December | 0.192453E+10 | 2149.62 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.785436E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -33.5 | |
| Maximum of Months | 0.267775E+10 | 2363.38 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.116207E+10 | 1249.19 | 11-JAN-01:00 | -31.1 |
| February | 0.484112E+09 | 865.66 | 04-FEB-03:00 | -21.7 |
| March | 0.190887E+09 | 838.52 | 06-MAR-04:00 | -18.3 |
| April | 7028525.49 | 258.82 | 29-APR-05:00 | -7.8 |
| May | 9259270.97 | 228.41 | 08-MAY-04:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 7551309.49 | 157.92 | 11-OCT-04:00 | 0.00 |
| November | 0.221808E+09 | 772.65 | 27-NOV-05:00 | -15.6 |
| December | 0.681573E+09 | 1137.57 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.276429E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.116207E+10 | 1249.19 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.116042E+10 | 1249.16 | 11-JAN-01:00 | -31.1 |
| February | 0.483831E+09 | 865.98 | 04-FEB-03:00 | -21.7 |
| March | 0.191019E+09 | 838.59 | 06-MAR-04:00 | -18.3 |
| April | 7089232.53 | 259.68 | 29-APR-05:00 | -7.8 |
| May | 9344000.27 | 227.34 | 08-MAY-04:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 7366736.57 | 158.59 | 11-OCT-04:00 | 0.00 |
| November | 0.222039E+09 | 772.84 | 27-NOV-05:00 | -15.6 |
| December | 0.681092E+09 | 1137.91 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.276220E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.116042E+10 | 1249.16 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.658382E+09 | 1207.30 | 11-JAN-08:15 | -15.7 |
| February | 0.167064E+09 | 734.87 | 04-FEB-03:00 | -21.7 |
| March | 63961861.66 | 668.15 | 06-MAR-04:00 | -18.3 |
| April | 3480354.53 | 219.80 | 29-APR-05:00 | -7.8 |
| May | 6413438.66 | 189.80 | 09-MAY-05:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 |
| November | 96207920.12 | 591.48 | 27-NOV-05:00 | -15.6 |
| December | 0.297458E+09 | 999.19 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.129297E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -24.4 | |
| Maximum of Months | 0.658382E+09 | 1207.30 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.657677E+09 | 1207.34 | 11-JAN-08:15 | -15.7 |
| February | 0.167309E+09 | 735.34 | 04-FEB-03:00 | -21.7 |
| March | 63979878.32 | 668.10 | 06-MAR-04:00 | -18.3 |
| April | 3486492.01 | 221.27 | 29-APR-05:00 | -7.8 |
| May | 6500301.50 | 193.98 | 09-MAY-05:00 | -2.2 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 |
| November | 96191679.19 | 590.69 | 27-NOV-05:00 | -15.6 |
| December | 0.297270E+09 | 999.50 | 31-DEC-03:00 | -24.4 |
| Annual Sum or Average | 0.129241E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -24.4 | |
| Maximum of Months | 0.657677E+09 | 1207.34 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.436105E+10 | 4101.89 | 11-JAN-01:00 | -31.1 |
| February | 0.231769E+10 | 3151.38 | 04-FEB-03:00 | -21.7 |
| March | 0.181620E+10 | 3140.46 | 05-MAR-01:10 | -22.2 |
| April | 0.734890E+09 | 1951.42 | 29-APR-05:00 | -7.8 |
| May | 0.520773E+09 | 1995.75 | 22-MAY-05:00 | -0.6 |
| June | 33824253.61 | 871.17 | 17-JUN-04:00 | 2.20 |
| July | 57883.53 | 166.94 | 08-JUL-06:05 | 9.78 |
| August | 25185868.53 | 695.93 | 18-AUG-05:00 | 7.20 |
| September | 0.217216E+09 | 1103.32 | 19-SEP-03:00 | 2.20 |
| October | 0.513558E+09 | 1608.83 | 10-OCT-06:00 | -6.1 |
| November | 0.165284E+10 | 2982.10 | 27-NOV-05:00 | -15.6 |
| December | 0.326080E+10 | 3618.67 | 31-DEC-08:00 | -27.8 |
| Annual Sum or Average | 0.154541E+11 | |||
| Minimum of Months | 57883.53 | 166.94 | -31.1 | |
| Maximum of Months | 0.436105E+10 | 4101.89 | 9.78 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.527176E+10 | 4132.15 | 10-JAN-23:10 | -33.5 |
| February | 0.309703E+10 | 3176.84 | 04-FEB-03:00 | -21.7 |
| March | 0.234235E+10 | 3167.35 | 04-MAR-02:00 | -18.3 |
| April | 0.896123E+09 | 1955.96 | 29-APR-05:00 | -7.8 |
| May | 0.563270E+09 | 2026.65 | 22-MAY-05:00 | -0.6 |
| June | 30564697.91 | 859.68 | 17-JUN-04:00 | 2.20 |
| July | 7844.49 | 13.07 | 09-JUL-03:40 | 6.10 |
| August | 26115096.43 | 698.73 | 18-AUG-05:00 | 7.20 |
| September | 0.294353E+09 | 1149.24 | 19-SEP-03:00 | 2.20 |
| October | 0.829755E+09 | 1647.80 | 10-OCT-07:18 | -5.4 |
| November | 0.230544E+10 | 3057.81 | 27-NOV-05:00 | -15.6 |
| December | 0.412691E+10 | 3653.52 | 31-DEC-08:02 | -27.6 |
| Annual Sum or Average | 0.197837E+11 | |||
| Minimum of Months | 7844.49 | 13.07 | -33.5 | |
| Maximum of Months | 0.527176E+10 | 4132.15 | 7.20 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.429863E+10 | 4079.49 | 11-JAN-01:00 | -31.1 |
| February | 0.228968E+10 | 3138.43 | 04-FEB-03:00 | -21.7 |
| March | 0.176233E+10 | 3126.32 | 05-MAR-01:10 | -22.2 |
| April | 0.721658E+09 | 1986.95 | 29-APR-05:00 | -7.8 |
| May | 0.516226E+09 | 1991.55 | 22-MAY-05:00 | -0.6 |
| June | 32849534.00 | 884.75 | 17-JUN-04:00 | 2.20 |
| July | 175669.07 | 100.79 | 08-JUL-03:30 | 5.85 |
| August | 21486781.95 | 695.70 | 18-AUG-05:00 | 7.20 |
| September | 0.205084E+09 | 1096.03 | 19-SEP-03:00 | 2.20 |
| October | 0.498386E+09 | 1600.98 | 10-OCT-06:00 | -6.1 |
| November | 0.164235E+10 | 2973.12 | 27-NOV-05:00 | -15.6 |
| December | 0.323089E+10 | 3600.53 | 31-DEC-08:00 | -27.8 |
| Annual Sum or Average | 0.152197E+11 | |||
| Minimum of Months | 175669.07 | 100.79 | -31.1 | |
| Maximum of Months | 0.429863E+10 | 4079.49 | 7.20 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.521314E+10 | 4109.52 | 10-JAN-23:10 | -33.5 |
| February | 0.305412E+10 | 3163.73 | 04-FEB-03:00 | -21.7 |
| March | 0.226559E+10 | 3165.06 | 04-MAR-02:00 | -18.3 |
| April | 0.871606E+09 | 1990.46 | 29-APR-05:00 | -7.8 |
| May | 0.565396E+09 | 2022.33 | 22-MAY-05:00 | -0.6 |
| June | 31485807.07 | 872.69 | 17-JUN-04:00 | 2.20 |
| July | 256534.16 | 128.86 | 08-JUL-03:30 | 5.85 |
| August | 22077457.84 | 697.86 | 18-AUG-05:00 | 7.20 |
| September | 0.268953E+09 | 1143.30 | 19-SEP-03:00 | 2.20 |
| October | 0.784710E+09 | 1627.20 | 10-OCT-06:35 | -6.1 |
| November | 0.229238E+10 | 3046.51 | 27-NOV-05:00 | -15.6 |
| December | 0.410046E+10 | 3636.35 | 31-DEC-08:07 | -27.6 |
| Annual Sum or Average | 0.194702E+11 | |||
| Minimum of Months | 256534.16 | 128.86 | -33.5 | |
| Maximum of Months | 0.521314E+10 | 4109.52 | 7.20 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.327869E+10 | 2728.97 | 11-JAN-01:00 | -31.1 |
| February | 0.183243E+10 | 2084.86 | 04-FEB-03:00 | -21.7 |
| March | 0.127286E+10 | 2067.34 | 05-MAR-01:10 | -22.2 |
| April | 0.403403E+09 | 1214.75 | 29-APR-05:00 | -7.8 |
| May | 0.251422E+09 | 1030.81 | 08-MAY-04:00 | -2.2 |
| June | 5215149.48 | 409.86 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 5582199.27 | 283.46 | 18-AUG-05:00 | 7.20 |
| September | 0.100192E+09 | 618.85 | 19-SEP-03:00 | 2.20 |
| October | 0.346223E+09 | 965.24 | 10-OCT-07:16 | -5.4 |
| November | 0.127689E+10 | 1976.02 | 27-NOV-05:00 | -15.6 |
| December | 0.248576E+10 | 2374.45 | 31-DEC-08:03 | -27.6 |
| Annual Sum or Average | 0.112587E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.327869E+10 | 2728.97 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.327660E+10 | 2728.52 | 11-JAN-01:00 | -31.1 |
| February | 0.183173E+10 | 2084.73 | 04-FEB-03:00 | -21.7 |
| March | 0.127162E+10 | 2067.19 | 05-MAR-01:10 | -22.2 |
| April | 0.403652E+09 | 1217.92 | 29-APR-05:00 | -7.8 |
| May | 0.253171E+09 | 1030.33 | 08-MAY-04:00 | -2.2 |
| June | 5249107.71 | 411.33 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 5464834.71 | 283.06 | 18-AUG-05:00 | 7.20 |
| September | 99902124.73 | 618.59 | 19-SEP-03:00 | 2.20 |
| October | 0.346316E+09 | 962.33 | 10-OCT-07:17 | -5.4 |
| November | 0.127744E+10 | 1975.72 | 27-NOV-05:00 | -15.6 |
| December | 0.248517E+10 | 2374.24 | 31-DEC-08:04 | -27.6 |
| Annual Sum or Average | 0.112563E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.327660E+10 | 2728.52 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.247106E+10 | 2714.13 | 11-JAN-01:00 | -31.1 |
| February | 0.118570E+10 | 2055.46 | 04-FEB-03:00 | -21.7 |
| March | 0.859037E+09 | 2036.14 | 05-MAR-01:10 | -22.2 |
| April | 0.288777E+09 | 1208.14 | 29-APR-05:00 | -7.8 |
| May | 0.219397E+09 | 994.27 | 08-MAY-04:00 | -2.2 |
| June | 6319802.31 | 420.51 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 5748403.12 | 279.96 | 18-AUG-05:00 | 7.20 |
| September | 62004431.51 | 567.90 | 19-SEP-03:00 | 2.20 |
| October | 0.167878E+09 | 919.77 | 10-OCT-06:00 | -6.1 |
| November | 0.776842E+09 | 1892.07 | 27-NOV-05:00 | -15.6 |
| December | 0.173361E+10 | 2331.80 | 31-DEC-08:04 | -27.6 |
| Annual Sum or Average | 0.777637E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.247106E+10 | 2714.13 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.246950E+10 | 2713.68 | 11-JAN-01:00 | -31.1 |
| February | 0.118617E+10 | 2055.35 | 04-FEB-03:00 | -21.7 |
| March | 0.858711E+09 | 2036.06 | 05-MAR-01:10 | -22.2 |
| April | 0.289469E+09 | 1211.30 | 29-APR-05:00 | -7.8 |
| May | 0.220426E+09 | 993.64 | 08-MAY-04:00 | -2.2 |
| June | 6343513.45 | 422.03 | 17-JUN-04:00 | 2.20 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 5694485.17 | 280.90 | 18-AUG-05:00 | 7.20 |
| September | 61950367.10 | 567.41 | 19-SEP-03:00 | 2.20 |
| October | 0.167936E+09 | 919.28 | 10-OCT-06:00 | -6.1 |
| November | 0.778054E+09 | 1891.79 | 27-NOV-05:00 | -15.6 |
| December | 0.173347E+10 | 2331.70 | 31-DEC-08:06 | -27.6 |
| Annual Sum or Average | 0.777773E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.246950E+10 | 2713.68 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -12.4 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -12.4 | |
| Maximum of Months | 0.00 | 0.00 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -12.4 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -12.4 | |
| Maximum of Months | 0.00 | 0.00 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.38 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -12.4 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -12.4 | |
| Maximum of Months | 0.00 | 0.00 | 19.45 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.824507E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.612012E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.559618E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.351957E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2231275.45 | 0.328176E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11458429.21 | 0.168552E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30099924.14 | 91338222.31 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24803980.36 | 0.125538E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11300453.35 | 0.257502E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 130631.23 | 0.361404E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.518120E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665817E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 80024693.74 | 0.486454E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91338222.31 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30099924.14 | 0.824507E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.824417E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.608350E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557639E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61230.64 | 0.345903E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2460838.58 | 0.320905E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11459567.71 | 0.164518E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30099959.28 | 90769642.69 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24804008.77 | 0.123262E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11306231.67 | 0.242324E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 167100.14 | 0.330884E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508502E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665722E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 80358936.79 | 0.478320E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90769642.69 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30099959.28 | 0.824417E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.731446E+09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.536405E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.506591E+09 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331062E+09 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1073092.06 | 0.326545E+09 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7150165.75 | 0.196877E+09 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18601003.96 | 0.133557E+09 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15786040.86 | 0.161144E+09 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4262877.44 | 0.296284E+09 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 130643.72 | 0.378320E+09 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.494537E+09 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.580899E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47003823.80 | 0.467367E+10 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133557E+09 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18601003.96 | 0.731446E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.824417E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.608331E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557638E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56744.26 | 0.345705E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2342375.98 | 0.320288E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11459090.01 | 0.165680E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30099985.60 | 90986384.01 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24804033.18 | 0.124477E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11300476.74 | 0.243870E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 150846.39 | 0.331496E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508292E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665722E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 80213552.15 | 0.478690E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90986384.01 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30099985.60 | 0.824417E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.497267E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366934E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336354E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37612.88 | 0.208557E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1529882.88 | 0.194104E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6913007.18 | 0.102129E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155562.92 | 55291973.53 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14961174.52 | 76086957.18 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6819839.91 | 0.149424E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 110407.53 | 0.202672E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307197E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401546E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 48527487.82 | 0.289756E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55291973.53 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155562.92 | 0.497267E+09 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.497267E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366935E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336354E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37240.16 | 0.208563E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1523318.82 | 0.194087E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6912788.65 | 0.102190E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155564.31 | 55293956.20 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14961174.64 | 76141507.98 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6818792.00 | 0.149499E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 110329.05 | 0.202727E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307194E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401546E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 48519207.63 | 0.289780E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55293956.20 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155564.31 | 0.497267E+09 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.497658E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370700E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338785E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214165E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1345816.77 | 0.199787E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6911447.76 | 0.104634E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155542.38 | 55553439.08 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14961157.78 | 77053663.48 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6816161.04 | 0.160344E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 78794.69 | 0.225153E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318761E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.402064E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 48268920.43 | 0.296466E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55553439.08 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155542.38 | 0.497658E+09 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.497547E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370252E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338491E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214044E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1345850.33 | 0.200131E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6911446.66 | 0.105247E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155541.90 | 55657850.30 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14961154.99 | 77275635.90 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6816158.49 | 0.161288E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 78794.69 | 0.225676E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318945E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401922E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 48268947.07 | 0.296648E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55657850.30 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18155541.90 | 0.497547E+09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118823E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.891969E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.822331E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.541200E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3176316.61 | 0.503314E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16369352.09 | 0.254812E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043012.01 | 0.132955E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35499588.28 | 0.182430E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16163761.94 | 0.374732E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182515.92 | 0.526566E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.754610E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.960064E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114435E+09 | 0.713322E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132955E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043012.01 | 0.118823E+10 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118566E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.876430E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.804312E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.518194E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3176325.84 | 0.493823E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16369368.41 | 0.254334E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043041.04 | 0.132783E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35499619.17 | 0.181180E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16163776.33 | 0.356087E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182544.09 | 0.486326E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733166E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.957576E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114435E+09 | 0.697987E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132783E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043041.04 | 0.118566E+10 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118832E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.892855E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.824289E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.543507E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3176329.14 | 0.503968E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16369385.06 | 0.255422E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043088.93 | 0.132978E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35499662.74 | 0.183042E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16163800.64 | 0.377020E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182518.76 | 0.528735E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.754691E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.959832E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114435E+09 | 0.714466E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132978E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043088.93 | 0.118832E+10 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118566E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.876166E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.803813E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.520812E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3176336.66 | 0.494567E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16369392.96 | 0.255180E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043105.37 | 0.132819E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35499668.18 | 0.182223E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16163795.78 | 0.359281E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 182527.91 | 0.487554E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.732544E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.957576E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114435E+09 | 0.698820E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132819E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43043105.37 | 0.118566E+10 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.715162E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528730E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.485145E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314103E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1915893.97 | 0.299314E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9873615.89 | 0.155147E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962536.99 | 80388232.38 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21412519.96 | 0.110997E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9749604.85 | 0.220044E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 110096.83 | 0.300788E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.444245E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577589E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 69024268.48 | 0.423165E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80388232.38 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962536.99 | 0.715162E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.715162E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528739E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.485158E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314349E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1915893.90 | 0.299361E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9873616.03 | 0.155155E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962537.24 | 80383803.10 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21412520.27 | 0.111033E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9749603.61 | 0.220207E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 110096.85 | 0.300889E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.444226E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577589E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 69024267.90 | 0.423225E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80383803.10 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962537.24 | 0.715162E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.719625E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.543422E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.502419E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.333547E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1915885.55 | 0.306505E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9873605.91 | 0.155302E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962513.73 | 80465584.57 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21412502.07 | 0.111454E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9749599.90 | 0.232878E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 110091.71 | 0.328479E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467053E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.582623E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 69024198.86 | 0.436377E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80465584.57 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962513.73 | 0.719625E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.719658E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.543472E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.502573E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.333662E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1915885.67 | 0.306474E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9873606.19 | 0.155302E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962511.62 | 80462033.57 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21412500.24 | 0.111470E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9749600.30 | 0.232941E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 110091.75 | 0.328531E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467058E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.582626E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 69024195.77 | 0.436423E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80462033.57 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25962511.62 | 0.719658E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157338E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117937E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108952E+10 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.701388E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4122123.62 | 0.649612E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21397096.59 | 0.314538E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375598.97 | 0.167158E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46574270.39 | 0.226868E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21181762.36 | 0.468469E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 228103.25 | 0.656126E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.986536E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127162E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149879E+09 | 0.928458E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167158E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375598.97 | 0.157338E+10 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157080E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116161E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106678E+10 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.681566E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4122127.82 | 0.639572E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21397101.11 | 0.313005E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375614.93 | 0.166765E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46574275.61 | 0.223943E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21181770.00 | 0.450730E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 230256.93 | 0.625070E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.970070E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126901E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149881E+09 | 0.913892E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166765E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375614.93 | 0.157080E+10 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157345E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118062E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109206E+10 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.705154E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4122151.91 | 0.652393E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21397170.56 | 0.318209E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375776.94 | 0.168818E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46574434.72 | 0.229244E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21181845.53 | 0.473320E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 228108.99 | 0.660009E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.985670E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127126E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149879E+09 | 0.931022E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168818E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375776.94 | 0.157345E+10 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157080E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116082E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106520E+10 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.684584E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4122150.55 | 0.641974E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21397155.41 | 0.317653E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375749.07 | 0.168410E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46574386.96 | 0.227230E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21181811.60 | 0.455026E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 228116.90 | 0.624509E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.969437E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126901E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149879E+09 | 0.915466E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168410E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56375749.07 | 0.157080E+10 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.947468E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.700128E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.642615E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.410670E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2486383.35 | 0.387886E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12906232.15 | 0.193418E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004436.91 | 0.102721E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28092500.03 | 0.138134E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12776344.51 | 0.274236E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 138274.00 | 0.377900E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.585333E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.765436E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 90404170.95 | 0.552594E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102721E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004436.91 | 0.947468E+09 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.947468E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.700124E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.642608E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.410942E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2486383.57 | 0.388027E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12906233.12 | 0.193624E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004436.05 | 0.102753E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28092501.46 | 0.138251E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12776344.92 | 0.274478E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 137602.24 | 0.377908E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.585311E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.765436E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 90403501.37 | 0.552693E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102753E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004436.05 | 0.947468E+09 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.950722E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.715309E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.661068E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.426679E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2486379.07 | 0.395978E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12906228.24 | 0.194086E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004426.64 | 0.102926E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28092503.60 | 0.139861E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12776348.91 | 0.288360E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 137590.09 | 0.404433E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.600201E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.769710E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 90403476.54 | 0.564934E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102926E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004426.64 | 0.950722E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.950741E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.715379E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.661210E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.426835E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2486379.69 | 0.396069E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12906229.68 | 0.194189E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004434.64 | 0.102949E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28092506.82 | 0.139918E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12776348.03 | 0.288506E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 137590.23 | 0.404607E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.600189E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.769735E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 90403489.08 | 0.565033E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102949E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34004434.64 | 0.950741E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258270E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197415E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184636E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123626E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 157898.95 | 0.119343E+09 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1426918.08 | 65531687.88 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4446708.57 | 38768758.30 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4149836.80 | 48750840.51 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1792370.40 | 88816749.78 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.24 | 0.116753E+09 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166436E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210488E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11973766.05 | 0.161883E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38768758.30 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4446708.57 | 0.258270E+09 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577851E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.394738E+10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380057E+10 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83893.23 | 0.251166E+10 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14952492.07 | 0.209891E+10 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 56472197.31 | 0.130626E+10 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182351E+09 | 0.884763E+09 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141362E+09 | 0.115950E+10 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 53605218.29 | 0.169334E+10 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 150731.10 | 0.262242E+10 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344219E+10 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.483172E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.448977E+09 | 0.340772E+11 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.884763E+09 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182351E+09 | 0.577851E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208425E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159252E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148950E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100949E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176127.34 | 96821897.12 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1317429.40 | 53650140.34 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3970384.22 | 30968573.30 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3613709.40 | 40041906.99 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1546053.46 | 74313347.23 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98687633.08 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136814E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170556E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10623703.81 | 0.131943E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30968573.30 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3970384.22 | 0.208425E+09 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1005.83 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 625.01 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 569.78 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 408.61 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.81 | 19-MAY-16:00 | 768.07 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.24 | 29-JUN-15:00 | 297.62 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 25-JUL-15:00 | 187.90 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.65 | 11-AUG-14:00 | 380.09 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.46 | 03-SEP-13:00 | 416.14 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.46 | 18-OCT-14:00 | 409.33 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 496.27 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 724.92 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.90 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 1005.83 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1005.83 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 625.01 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 569.78 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.80 | 07-APR-14:00 | 408.61 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.81 | 19-MAY-16:00 | 768.07 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.24 | 29-JUN-15:00 | 291.78 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 25-JUL-15:00 | 187.90 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.65 | 11-AUG-14:00 | 373.73 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.46 | 03-SEP-13:00 | 411.89 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.25 | 18-OCT-14:00 | 398.40 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 496.27 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 724.92 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.90 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 1005.83 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1005.83 | 05-JAN-16:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 625.01 | 01-FEB-15:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 525.64 | 30-MAR-08:07 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 408.61 | 27-APR-11:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.81 | 19-MAY-16:00 | 741.70 | 22-MAY-04:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.24 | 29-JUN-15:00 | 320.76 | 14-JUN-02:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 25-JUL-15:00 | 233.72 | 08-JUL-10:00 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.65 | 11-AUG-14:00 | 418.81 | 17-AUG-12:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.06 | 02-SEP-15:00 | 450.69 | 18-SEP-16:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.46 | 18-OCT-14:00 | 452.12 | 31-OCT-10:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 491.71 | 28-NOV-09:10 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 723.72 | 27-DEC-14:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 233.72 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 1005.83 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1005.83 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 625.01 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 569.78 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.04 | 07-APR-14:00 | 408.61 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.81 | 19-MAY-16:00 | 768.07 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.24 | 29-JUN-15:00 | 292.51 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 25-JUL-15:00 | 187.00 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.65 | 11-AUG-14:00 | 376.75 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.46 | 03-SEP-13:00 | 411.84 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.10 | 18-OCT-14:00 | 398.40 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 496.27 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 724.92 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.00 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 156.55 | 1005.83 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 606.69 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 376.99 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 343.68 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.78 | 07-APR-14:00 | 246.46 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 57.19 | 19-MAY-16:00 | 463.28 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.03 | 29-JUN-15:00 | 184.65 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 25-JUL-15:00 | 114.44 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.68 | 11-AUG-14:00 | 236.90 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.15 | 03-SEP-13:00 | 261.39 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.39 | 18-OCT-14:00 | 240.31 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 299.33 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 437.25 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.44 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 606.69 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 606.69 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 376.99 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 343.68 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.73 | 07-APR-14:00 | 246.46 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 57.19 | 19-MAY-16:00 | 463.28 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.03 | 29-JUN-15:00 | 184.83 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 25-JUL-15:00 | 114.37 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.68 | 11-AUG-14:00 | 237.09 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.15 | 03-SEP-13:00 | 261.37 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.40 | 18-OCT-14:00 | 240.31 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 299.33 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 437.25 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.37 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 606.69 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 606.69 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 376.99 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 343.68 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 246.46 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 57.19 | 19-MAY-16:00 | 463.28 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.03 | 29-JUN-15:00 | 188.45 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 25-JUL-15:00 | 114.69 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.68 | 11-AUG-14:00 | 240.71 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.15 | 03-SEP-13:00 | 264.32 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.72 | 18-OCT-14:00 | 264.80 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 299.33 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 437.25 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.69 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 606.69 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 606.69 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 376.99 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 343.68 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 246.46 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 57.19 | 19-MAY-16:00 | 463.54 | 22-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.03 | 29-JUN-15:00 | 189.78 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 25-JUL-15:00 | 115.46 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.68 | 11-AUG-14:00 | 242.78 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.15 | 03-SEP-13:00 | 266.50 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.72 | 18-OCT-14:00 | 266.32 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 299.33 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 437.25 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.46 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 94.43 | 606.69 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1446.17 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 898.80 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 819.40 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 587.69 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.53 | 19-MAY-16:00 | 1104.79 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.12 | 29-JUN-15:00 | 452.06 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 25-JUL-15:00 | 273.31 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.28 | 11-AUG-14:00 | 549.96 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.33 | 03-SEP-13:00 | 595.30 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 | 18-OCT-14:00 | 594.33 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 713.73 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1042.80 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 273.31 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 1446.17 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1446.17 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 898.80 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 819.40 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 587.69 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.53 | 19-MAY-16:00 | 1104.79 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.12 | 29-JUN-15:00 | 451.11 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 25-JUL-15:00 | 275.46 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.27 | 11-AUG-14:00 | 545.36 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.33 | 03-SEP-13:00 | 584.88 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 | 18-OCT-14:00 | 573.27 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 713.73 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1042.80 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 275.46 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 1446.17 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1446.17 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 898.80 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 819.40 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 587.69 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.53 | 19-MAY-16:00 | 1104.79 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.12 | 29-JUN-15:00 | 450.35 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 25-JUL-15:00 | 280.85 | 08-JUL-10:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.28 | 11-AUG-14:00 | 552.13 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.33 | 03-SEP-13:00 | 597.24 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 | 18-OCT-14:00 | 614.86 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 713.73 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1042.80 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 280.85 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 1446.17 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1446.17 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 898.80 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 819.40 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 587.69 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.53 | 19-MAY-16:00 | 1104.79 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.12 | 29-JUN-15:00 | 449.57 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 25-JUL-15:00 | 279.50 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.28 | 11-AUG-14:00 | 547.89 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.33 | 03-SEP-13:00 | 585.64 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 | 18-OCT-14:00 | 573.27 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 713.73 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1042.80 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 279.50 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 224.55 | 1446.17 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 872.29 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 542.13 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 494.24 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 354.48 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.75 | 19-MAY-16:00 | 682.34 | 22-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.37 | 29-JUN-15:00 | 280.79 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 25-JUL-15:00 | 171.11 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 132.86 | 11-AUG-14:00 | 345.42 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.28 | 03-SEP-13:00 | 375.48 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.29 | 18-OCT-14:00 | 345.78 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 430.50 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 628.99 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 171.11 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 872.29 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 872.29 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 542.13 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 494.24 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 354.48 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.75 | 19-MAY-16:00 | 682.28 | 22-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.37 | 29-JUN-15:00 | 280.75 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 25-JUL-15:00 | 170.99 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 132.86 | 11-AUG-14:00 | 345.58 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.28 | 03-SEP-13:00 | 375.54 | 12-SEP-03:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.29 | 18-OCT-14:00 | 345.78 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 430.50 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 628.99 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.99 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 872.29 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 872.29 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 544.86 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 505.25 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 361.30 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.75 | 19-MAY-16:00 | 685.28 | 22-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.37 | 29-JUN-15:00 | 281.39 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 25-JUL-15:00 | 169.75 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 132.86 | 11-AUG-14:00 | 348.28 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.28 | 03-SEP-13:00 | 379.46 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.29 | 18-OCT-14:00 | 387.04 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 430.50 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 628.99 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.75 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 872.29 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 872.29 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 544.97 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 504.96 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 361.41 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.75 | 19-MAY-16:00 | 685.28 | 22-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.37 | 29-JUN-15:00 | 281.33 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 25-JUL-15:00 | 169.65 | 08-JUL-07:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 132.86 | 11-AUG-14:00 | 348.40 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.28 | 03-SEP-13:00 | 379.63 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.29 | 18-OCT-14:00 | 387.38 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 430.50 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 628.99 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.65 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 135.44 | 872.29 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1914.89 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1190.57 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1085.46 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 778.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.40 | 19-MAY-16:00 | 1464.08 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.07 | 29-JUN-15:00 | 515.28 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 25-JUL-15:00 | 359.56 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 289.96 | 11-AUG-14:00 | 652.10 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.30 | 03-SEP-13:00 | 767.09 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.85 | 18-OCT-14:00 | 760.25 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 945.59 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1382.15 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 359.56 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 1914.89 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1914.89 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1190.57 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1085.46 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 778.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.40 | 19-MAY-16:00 | 1464.08 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.07 | 29-JUN-15:00 | 515.31 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 25-JUL-15:00 | 359.56 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 289.96 | 11-AUG-14:00 | 652.10 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.30 | 03-SEP-13:00 | 767.09 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.86 | 18-OCT-14:00 | 760.25 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 945.59 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1382.15 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 359.56 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 1914.89 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1914.89 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1190.57 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1085.46 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 778.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.40 | 19-MAY-16:00 | 1464.08 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.07 | 29-JUN-15:00 | 515.16 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 25-JUL-15:00 | 359.41 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 289.97 | 11-AUG-14:00 | 652.10 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.30 | 03-SEP-13:00 | 767.09 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.86 | 18-OCT-14:00 | 760.25 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 945.59 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1382.15 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 359.41 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 1914.89 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1914.89 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1190.57 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1085.46 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 778.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.40 | 19-MAY-16:00 | 1464.08 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 291.07 | 29-JUN-15:00 | 515.22 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 25-JUL-15:00 | 359.43 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 289.97 | 11-AUG-14:00 | 652.10 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.30 | 03-SEP-13:00 | 767.09 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.86 | 18-OCT-14:00 | 760.25 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 945.59 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1382.15 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 359.43 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 295.90 | 1914.89 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1155.02 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 718.12 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 654.72 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 469.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.01 | 19-MAY-16:00 | 883.10 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.57 | 29-JUN-15:00 | 331.31 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 25-JUL-15:00 | 216.87 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 174.90 | 11-AUG-14:00 | 393.33 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.27 | 03-SEP-13:00 | 462.69 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.60 | 18-OCT-14:00 | 458.57 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 570.36 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 833.68 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 216.87 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 1155.02 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1155.02 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 718.12 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 654.72 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 469.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.01 | 19-MAY-16:00 | 883.10 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.57 | 29-JUN-15:00 | 331.07 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 25-JUL-15:00 | 216.87 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 174.90 | 11-AUG-14:00 | 393.33 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.27 | 03-SEP-13:00 | 462.69 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.60 | 18-OCT-14:00 | 458.57 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 570.36 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 833.68 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 216.87 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 1155.02 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1155.02 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 718.12 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 654.72 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 469.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.01 | 19-MAY-16:00 | 883.10 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.57 | 29-JUN-15:00 | 330.55 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 25-JUL-15:00 | 216.87 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 174.90 | 11-AUG-14:00 | 393.33 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.27 | 03-SEP-13:00 | 462.69 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.60 | 18-OCT-14:00 | 458.57 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 570.36 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 833.68 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 216.87 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 1155.02 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1155.02 | 05-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 718.12 | 01-FEB-15:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 654.72 | 02-MAR-23:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 469.68 | 27-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.01 | 19-MAY-16:00 | 883.10 | 22-MAY-05:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.57 | 29-JUN-15:00 | 330.28 | 14-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 25-JUL-15:00 | 216.84 | 07-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 174.90 | 11-AUG-14:00 | 393.33 | 17-AUG-12:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.27 | 03-SEP-13:00 | 462.69 | 18-SEP-16:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.60 | 18-OCT-14:00 | 458.57 | 31-OCT-10:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 570.36 | 28-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 833.68 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 216.84 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 178.48 | 1155.02 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 310.33 | 05-JAN-16:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 197.03 | 01-FEB-15:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 194.69 | 14-MAR-18:55 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 130.95 | 27-APR-11:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.97 | 20-MAY-16:00 | 252.52 | 22-MAY-04:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.92 | 29-JUN-15:00 | 107.15 | 14-JUN-02:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.53 | 25-JUL-15:00 | 76.09 | 07-JUL-19:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.41 | 05-AUG-14:00 | 120.33 | 17-AUG-12:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.68 | 03-SEP-13:00 | 134.89 | 18-SEP-16:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.06 | 18-OCT-14:00 | 129.11 | 31-OCT-10:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 152.01 | 28-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 223.02 | 27-DEC-14:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.09 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.53 | 310.33 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 26273.00 | 29-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 23842.67 | 01-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 21264.74 | 04-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.70 | 07-APR-14:00 | 13625.15 | 29-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1950.05 | 20-MAY-16:03 | 11603.03 | 22-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2015.51 | 28-JUN-16:02 | 10269.30 | 16-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4198.86 | 17-JUL-16:01 | 7502.50 | 05-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3637.21 | 05-AUG-16:01 | 8893.21 | 28-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2975.47 | 02-SEP-16:02 | 11045.58 | 17-SEP-06:01 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.95 | 18-OCT-14:00 | 13822.75 | 10-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 18597.09 | 26-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 25325.88 | 31-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7502.50 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 4198.86 | 26273.00 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 248.78 | 05-JAN-16:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 157.60 | 01-FEB-15:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 151.30 | 02-MAR-23:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 110.98 | 27-APR-11:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.69 | 20-MAY-16:00 | 217.23 | 22-MAY-04:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.24 | 29-JUN-15:00 | 90.34 | 14-JUN-02:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.54 | 25-JUL-15:00 | 58.66 | 08-JUL-10:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.75 | 11-AUG-14:00 | 109.33 | 17-AUG-12:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.96 | 02-SEP-14:00 | 119.06 | 12-SEP-03:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 112.18 | 31-OCT-10:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 123.27 | 28-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 181.56 | 01-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.66 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.54 | 248.78 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 439.53 | 15-JAN-15:40 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.54 |
| February | 570.94 | 28-FEB-22:25 | 475.00 | 104.17 | 835.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.07 |
| March | 557.11 | 01-MAR-20:00 | 237.50 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.02 |
| April | 445.94 | 25-APR-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.27 |
| May | 933.59 | 19-MAY-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 88.35 | 0.00 |
| June | 1682.35 | 24-JUN-16:20 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 65.86 | 0.00 |
| July | 2268.83 | 17-JUL-17:16 | 1187.50 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 68.42 | 0.00 |
| August | 2310.16 | 10-AUG-17:07 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 112.73 | 0.00 |
| September | 2420.71 | 02-SEP-16:05 | 1425.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 77.92 | 0.00 |
| October | 1720.16 | 18-OCT-16:10 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.70 |
| November | 672.43 | 11-NOV-11:50 | 118.75 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.95 |
| December | 388.34 | 07-DEC-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 281.29 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 388.34 | 0.00 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2420.71 | 1425.00 | 585.91 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 112.73 | 281.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.52 |
| February | 268.88 | 26-FEB-18:02 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.56 |
| March | 247.28 | 29-MAR-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.27 |
| April | 310.99 | 10-APR-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.02 |
| May | 696.34 | 31-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.27 |
| June | 1512.32 | 30-JUN-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 37.03 | 0.00 |
| July | 1996.18 | 17-JUL-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 51.86 | 0.00 |
| August | 1847.13 | 10-AUG-17:27 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 122.07 | 0.00 |
| September | 1737.54 | 04-SEP-17:07 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 39.65 | 0.00 |
| October | 548.91 | 21-OCT-00:40 | 237.50 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.88 |
| November | 341.63 | 05-NOV-20:10 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.98 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 427.36 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 206.62 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1996.18 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 122.07 | 427.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1465.40 | 11-JAN-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 284.91 |
| February | 1429.49 | 01-FEB-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.65 |
| March | 1160.61 | 06-MAR-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.23 |
| April | 586.97 | 04-APR-07:02 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.26 |
| May | 2309.10 | 19-MAY-08:63 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.67 |
| June | 6334.80 | 26-JUN-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.92 |
| July | 6459.07 | 27-JUL-07:01 | 3158.44 | 4080.41 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.76 |
| August | 6496.88 | 01-AUG-07:01 | 3158.44 | 4080.41 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.18 |
| September | 6408.55 | 05-SEP-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.51 |
| October | 5615.89 | 19-OCT-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 113.40 |
| November | 964.34 | 27-NOV-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 303.10 |
| December | 1422.19 | 29-DEC-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 586.97 | 0.00 | 1165.83 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6496.88 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 303.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.52 |
| February | 164.40 | 27-FEB-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.49 |
| March | 247.28 | 29-MAR-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.27 |
| April | 303.18 | 25-APR-09:00 | 59.38 | 17.36 | 394.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.54 |
| May | 490.52 | 20-MAY-16:10 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 67.76 | 0.00 |
| June | 1231.24 | 29-JUN-16:02 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 118.31 | 0.00 |
| July | 1623.78 | 17-JUL-17:14 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 68.42 | 0.00 |
| August | 1574.90 | 06-AUG-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 124.38 | 0.00 |
| September | 1462.83 | 03-SEP-16:15 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 128.90 | 0.00 |
| October | 556.59 | 21-OCT-00:50 | 237.50 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.25 |
| November | 334.05 | 05-NOV-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.19 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 427.36 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 59.38 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1623.78 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 128.90 | 427.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 3.12 | 01-JAN-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.71 |
| February | 251.73 | 27-FEB-17:12 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.82 |
| March | 247.29 | 29-MAR-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.14 |
| April | 325.61 | 08-APR-19:30 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.39 |
| May | 497.32 | 22-MAY-01:30 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 288.90 |
| June | 979.20 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 47.01 | 0.00 |
| July | 1268.78 | 17-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 22.33 | 0.00 |
| August | 1219.78 | 06-AUG-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 75.02 | 0.00 |
| September | 1147.62 | 04-SEP-17:20 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 22.64 | 0.00 |
| October | 600.74 | 21-OCT-04:00 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.70 |
| November | 408.03 | 05-NOV-21:50 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.41 |
| December | 104.84 | 06-DEC-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.42 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3.12 | 206.62 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1268.78 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 75.02 | 288.90 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4.12 | 01-JAN-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.71 |
| February | 251.66 | 27-FEB-17:12 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.79 |
| March | 247.29 | 29-MAR-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.14 |
| April | 325.97 | 08-APR-19:30 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.47 |
| May | 497.25 | 22-MAY-01:30 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 288.86 |
| June | 974.79 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 47.01 | 0.00 |
| July | 1263.20 | 17-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 22.33 | 0.00 |
| August | 1215.63 | 06-AUG-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 75.02 | 0.00 |
| September | 1142.06 | 04-SEP-17:15 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 22.64 | 0.00 |
| October | 600.83 | 21-OCT-04:00 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.72 |
| November | 407.90 | 05-NOV-21:50 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.40 |
| December | 102.82 | 06-DEC-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.42 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4.12 | 206.62 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1263.20 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 75.02 | 288.86 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 538.98 | 15-JAN-17:25 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.98 |
| February | 647.90 | 28-FEB-24:00 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.67 |
| March | 705.29 | 01-MAR-01:30 | 237.50 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.98 |
| April | 476.28 | 08-APR-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.83 |
| May | 731.20 | 20-MAY-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 40.87 | 0.00 |
| June | 1238.17 | 24-JUN-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 42.16 | 0.00 |
| July | 1587.44 | 17-JUL-16:04 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 63.36 | 0.00 |
| August | 1736.62 | 10-AUG-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 61.94 | 0.00 |
| September | 1901.38 | 02-SEP-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 80.42 | 0.00 |
| October | 1511.85 | 18-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 7.84 | 0.00 |
| November | 763.30 | 11-NOV-09:40 | 237.50 | 17.36 | 394.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.52 |
| December | 638.20 | 12-DEC-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.53 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 476.28 | 0.00 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1901.38 | 950.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 80.42 | 107.53 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 516.68 | 01-JAN-20:00 | 237.50 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.26 |
| February | 646.15 | 28-FEB-24:00 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.49 |
| March | 689.90 | 01-MAR-01:10 | 237.50 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.32 |
| April | 477.74 | 08-APR-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.06 |
| May | 786.53 | 20-MAY-16:10 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 40.87 | 0.00 |
| June | 1340.17 | 24-JUN-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 42.16 | 0.00 |
| July | 1683.85 | 17-JUL-16:04 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 63.36 | 0.00 |
| August | 1817.10 | 10-AUG-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 61.94 | 0.00 |
| September | 2022.59 | 02-SEP-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 80.42 | 0.00 |
| October | 1550.90 | 18-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 7.84 | 0.00 |
| November | 768.51 | 11-NOV-09:30 | 237.50 | 17.36 | 394.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.22 |
| December | 628.07 | 12-DEC-14:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.91 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 477.74 | 0.00 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2022.59 | 950.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 80.42 | 136.91 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 879.91 | 28-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1297.23 | 26-FEB-17:03 | 1425.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.23 |
| March | 1088.75 | 01-MAR-16:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.11 |
| April | 1723.97 | 06-APR-16:20 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.88 |
| May | 2411.40 | 19-MAY-17:30 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 70.86 | 0.00 |
| June | 2519.74 | 28-JUN-17:40 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 101.78 | 0.00 |
| July | 2916.29 | 17-JUL-16:17 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 143.07 | 0.00 |
| August | 2944.42 | 10-AUG-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 122.58 | 0.00 |
| September | 3087.79 | 02-SEP-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 173.70 | 0.00 |
| October | 2435.30 | 18-OCT-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 14.13 | 0.00 |
| November | 852.65 | 03-NOV-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.26 |
| December | 695.34 | 12-DEC-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 391.16 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 695.34 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3087.79 | 1425.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 173.70 | 391.16 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 211.95 | 14-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.06 |
| February | 472.45 | 27-FEB-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188.97 |
| March | 503.02 | 01-MAR-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.85 |
| April | 710.40 | 25-APR-18:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.36 |
| May | 2010.02 | 19-MAY-17:40 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 68.42 | 0.00 |
| June | 2392.41 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 106.50 | 0.00 |
| July | 2616.03 | 17-JUL-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 74.41 | 0.00 |
| August | 2420.54 | 10-AUG-17:30 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 174.97 | 0.00 |
| September | 2154.47 | 04-SEP-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 63.80 | 0.00 |
| October | 747.24 | 18-OCT-16:08 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.41 |
| November | 421.89 | 05-NOV-22:10 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.20 |
| December | 90.89 | 06-DEC-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 282.52 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 90.89 | 71.25 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2616.03 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 174.97 | 282.52 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 685.03 | 28-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1090.33 | 26-FEB-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.93 |
| March | 835.25 | 01-MAR-04:10 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.84 |
| April | 1463.09 | 25-APR-12:20 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.81 |
| May | 2042.47 | 19-MAY-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 86.18 | 0.00 |
| June | 2254.60 | 29-JUN-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 214.54 | 0.00 |
| July | 2646.36 | 25-JUL-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 214.31 | 0.00 |
| August | 2732.67 | 10-AUG-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 188.87 | 0.00 |
| September | 2879.74 | 02-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 212.44 | 0.00 |
| October | 2153.41 | 18-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 | 0.00 |
| November | 779.75 | 11-NOV-09:10 | 237.50 | 17.36 | 394.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.33 |
| December | 689.17 | 12-DEC-11:10 | 0.00 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 220.40 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 685.03 | 0.00 | 17.36 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2879.74 | 237.50 | 30.38 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 214.54 | 220.40 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 122.38 | 14-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.06 |
| February | 472.07 | 27-FEB-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188.82 |
| March | 482.34 | 23-MAR-19:20 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.49 |
| April | 575.77 | 13-APR-00:50 | 237.50 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126.28 |
| May | 1498.85 | 20-MAY-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 97.05 | 0.00 |
| June | 1857.68 | 23-JUN-09:30 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 41.04 | 0.00 |
| July | 2027.43 | 17-JUL-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 150.73 | 0.00 |
| August | 1959.06 | 06-AUG-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 178.39 | 0.00 |
| September | 1749.41 | 03-SEP-16:20 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 184.82 | 0.00 |
| October | 595.56 | 21-OCT-08:00 | 92.63 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 205.18 |
| November | 414.55 | 05-NOV-22:00 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.63 |
| December | 76.58 | 09-DEC-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 121.16 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 76.58 | 59.38 | 8.68 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2027.43 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 184.82 | 205.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 342.28 | 01-JAN-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.50 |
| February | 542.29 | 27-FEB-22:35 | 475.00 | 104.17 | 835.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.76 |
| March | 534.51 | 14-MAR-21:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.45 |
| April | 618.63 | 27-APR-06:10 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.12 |
| May | 1201.70 | 20-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.41 | 0.00 |
| June | 1391.54 | 23-JUN-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 10.79 | 0.00 |
| July | 1534.42 | 17-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 32.03 | 0.00 |
| August | 1465.70 | 06-AUG-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 113.60 | 0.00 |
| September | 1327.45 | 03-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 113.59 | 0.00 |
| October | 632.66 | 26-OCT-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.59 |
| November | 521.51 | 06-NOV-00:50 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.35 |
| December | 287.14 | 05-DEC-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.94 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 287.14 | 123.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1534.42 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 113.60 | 176.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 343.83 | 01-JAN-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.50 |
| February | 542.36 | 27-FEB-22:35 | 475.00 | 104.17 | 835.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.77 |
| March | 534.51 | 14-MAR-21:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.45 |
| April | 619.36 | 27-APR-06:10 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.32 |
| May | 1199.38 | 20-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.41 | 0.00 |
| June | 1387.42 | 23-JUN-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 10.79 | 0.00 |
| July | 1525.06 | 17-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 32.03 | 0.00 |
| August | 1461.97 | 06-AUG-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 113.60 | 0.00 |
| September | 1325.16 | 03-SEP-16:20 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 111.48 | 0.00 |
| October | 633.26 | 26-OCT-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.65 |
| November | 516.02 | 06-NOV-00:40 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.45 |
| December | 287.03 | 05-DEC-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.94 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 287.03 | 206.62 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1525.06 | 2018.75 | 564.16 | 3826.05 | 0.00 | 0.00 | 0.00 | 0.00 | 113.60 | 176.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1097.45 | 28-JAN-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.26 |
| February | 1261.73 | 28-FEB-14:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.45 |
| March | 1074.40 | 01-MAR-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.64 |
| April | 1264.36 | 06-APR-16:10 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.13 |
| May | 1650.89 | 19-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 76.06 | 0.00 |
| June | 1691.28 | 29-JUN-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 129.40 | 0.00 |
| July | 1989.35 | 25-JUL-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 124.56 | 0.00 |
| August | 2098.94 | 10-AUG-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 88.83 | 0.00 |
| September | 2327.44 | 02-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 127.85 | 0.00 |
| October | 2082.38 | 18-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 12.28 | 0.00 |
| November | 1127.76 | 06-NOV-13:40 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.19 |
| December | 782.77 | 12-DEC-17:45 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 219.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 782.77 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2327.44 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 129.40 | 219.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1097.48 | 28-JAN-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.26 |
| February | 1274.83 | 28-FEB-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.21 |
| March | 1085.41 | 01-MAR-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.64 |
| April | 1274.68 | 06-APR-16:10 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.13 |
| May | 1652.75 | 19-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 76.06 | 0.00 |
| June | 1696.36 | 24-JUN-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 97.24 | 0.00 |
| July | 1991.93 | 25-JUL-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 124.56 | 0.00 |
| August | 2104.07 | 10-AUG-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 83.76 | 0.00 |
| September | 2333.18 | 02-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 127.85 | 0.00 |
| October | 2085.90 | 18-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 12.28 | 0.00 |
| November | 1137.74 | 06-NOV-13:40 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.19 |
| December | 776.99 | 12-DEC-17:35 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 217.21 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 776.99 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2333.18 | 118.75 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 127.85 | 217.21 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 838.25 | 28-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1933.13 | 26-FEB-17:00 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.08 |
| March | 1500.05 | 01-MAR-16:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.36 |
| April | 2569.63 | 06-APR-16:10 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.37 |
| May | 3243.51 | 19-MAY-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 165.12 | 0.00 |
| June | 3336.15 | 30-JUN-17:15 | 475.00 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 69.10 | 0.00 |
| July | 4091.77 | 17-JUL-16:04 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 198.77 | 0.00 |
| August | 3927.21 | 10-AUG-16:17 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 147.95 | 0.00 |
| September | 4122.61 | 02-SEP-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 228.88 | 0.00 |
| October | 2962.93 | 18-OCT-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 20.35 | 0.00 |
| November | 1506.82 | 03-NOV-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.68 |
| December | 675.98 | 12-DEC-15:50 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 521.31 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 675.98 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4122.61 | 475.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 228.88 | 521.31 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 73.16 | 14-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 197.86 |
| February | 386.49 | 28-FEB-18:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 231.77 |
| March | 471.62 | 02-MAR-18:12 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 338.11 |
| April | 1160.55 | 06-APR-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.85 |
| May | 2747.51 | 19-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.71 | 0.00 |
| June | 3149.25 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 139.94 | 0.00 |
| July | 3616.13 | 17-JUL-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 118.98 | 0.00 |
| August | 3273.53 | 06-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 212.21 | 0.00 |
| September | 2909.05 | 04-SEP-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 84.01 | 0.00 |
| October | 1110.10 | 18-OCT-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.92 |
| November | 299.71 | 01-NOV-17:40 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 223.55 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 814.48 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3616.13 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 212.21 | 814.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 599.65 | 31-JAN-12:50 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 550.96 |
| February | 1732.86 | 26-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.19 |
| March | 1319.93 | 20-MAR-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.25 |
| April | 1981.72 | 06-APR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.91 |
| May | 2759.39 | 19-MAY-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 112.65 | 0.00 |
| June | 3045.17 | 23-JUN-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 66.63 | 0.00 |
| July | 3643.69 | 25-JUL-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 282.35 | 0.00 |
| August | 3679.28 | 10-AUG-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 248.62 | 0.00 |
| September | 3836.20 | 02-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 279.89 | 0.00 |
| October | 2579.65 | 18-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 25.85 | 0.00 |
| November | 1287.94 | 03-NOV-13:50 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.36 |
| December | 647.12 | 12-DEC-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 344.36 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 599.65 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3836.20 | 118.75 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 282.35 | 550.96 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.05 |
| February | 343.89 | 27-FEB-18:40 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 382.16 |
| March | 380.34 | 14-MAR-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 391.16 |
| April | 714.06 | 24-APR-18:50 | 413.25 | 277.76 | 1094.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 165.19 |
| May | 1957.30 | 19-MAY-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 165.12 | 0.00 |
| June | 2417.74 | 29-JUN-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 282.38 | 0.00 |
| July | 2805.40 | 17-JUL-16:07 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 198.77 | 0.00 |
| August | 2647.63 | 06-AUG-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 209.25 | 0.00 |
| September | 2290.91 | 03-SEP-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 234.59 | 0.00 |
| October | 579.66 | 18-OCT-16:10 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.92 |
| November | 275.50 | 01-NOV-17:17 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 208.81 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 814.48 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2805.40 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 282.38 | 814.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 100.20 | 14-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.35 |
| February | 394.83 | 27-FEB-19:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 251.82 |
| March | 419.54 | 14-MAR-18:25 | 413.25 | 277.76 | 1094.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 408.61 |
| April | 515.41 | 25-APR-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.41 |
| May | 1558.77 | 20-MAY-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 76.90 | 0.00 |
| June | 1856.47 | 29-JUN-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 134.43 | 0.00 |
| July | 2187.19 | 17-JUL-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 119.89 | 0.00 |
| August | 2053.46 | 06-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 127.12 | 0.00 |
| September | 1812.27 | 03-SEP-16:20 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 146.81 | 0.00 |
| October | 462.26 | 20-OCT-20:20 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.87 |
| November | 348.33 | 05-NOV-20:20 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.09 |
| December | 16.64 | 09-DEC-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.08 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 16.64 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2187.19 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 146.81 | 408.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 98.42 | 14-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.35 |
| February | 394.34 | 27-FEB-19:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 251.53 |
| March | 419.25 | 14-MAR-18:25 | 413.25 | 277.76 | 1094.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 408.35 |
| April | 514.49 | 25-APR-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.41 |
| May | 1556.23 | 20-MAY-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 76.90 | 0.00 |
| June | 1850.43 | 29-JUN-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 134.43 | 0.00 |
| July | 2177.32 | 17-JUL-16:04 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 119.89 | 0.00 |
| August | 2045.23 | 06-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 127.12 | 0.00 |
| September | 1803.46 | 03-SEP-16:20 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 146.81 | 0.00 |
| October | 461.96 | 20-OCT-20:20 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.81 |
| November | 347.97 | 05-NOV-20:20 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.00 |
| December | 16.33 | 09-DEC-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.08 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 16.33 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2177.32 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 146.81 | 408.35 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1093.59 | 28-JAN-14:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1695.46 | 26-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.13 |
| March | 1250.37 | 20-MAR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.85 |
| April | 1710.11 | 06-APR-16:10 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.71 |
| May | 2256.18 | 19-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 99.66 | 0.00 |
| June | 2369.10 | 24-JUN-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 127.68 | 0.00 |
| July | 2860.96 | 25-JUL-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 153.13 | 0.00 |
| August | 2958.24 | 09-AUG-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 76.87 | 0.00 |
| September | 3194.60 | 02-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 168.82 | 0.00 |
| October | 2370.86 | 18-OCT-14:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 15.59 | 0.00 |
| November | 1372.03 | 03-NOV-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.02 |
| December | 709.45 | 12-DEC-16:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 307.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 709.45 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3194.60 | 118.75 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 168.82 | 307.51 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1093.59 | 28-JAN-14:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1717.39 | 26-FEB-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.13 |
| March | 1262.64 | 20-MAR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.85 |
| April | 1710.93 | 06-APR-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.34 |
| May | 2262.56 | 19-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 99.66 | 0.00 |
| June | 2382.46 | 24-JUN-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 127.68 | 0.00 |
| July | 2868.80 | 25-JUL-14:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 144.90 | 0.00 |
| August | 2971.37 | 09-AUG-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 76.87 | 0.00 |
| September | 3205.62 | 02-SEP-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 168.82 | 0.00 |
| October | 2379.74 | 18-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 15.59 | 0.00 |
| November | 1385.99 | 03-NOV-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.02 |
| December | 708.93 | 12-DEC-16:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 307.29 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 708.93 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3205.62 | 118.75 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 168.82 | 307.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.32 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.99 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.57 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.22 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.26 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.47 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.97 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.89 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.46 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.78 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.93 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 133.01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.47 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.38 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.99 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.55 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.12 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.76 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.62 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.15 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.46 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.61 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.23 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.84 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.62 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.11 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 109.75 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.55 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.48 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.60 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.06 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.50 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.08 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.31 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.06 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.74 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.98 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.06 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 109.75 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.109136E+12 | 74615.50 | 10-JAN-18:10 | 0.165786E+12 | 141409.12 | 10-JAN-23:10 |
| February | 0.969842E+11 | 69727.78 | 02-FEB-18:49 | 0.951809E+11 | 105610.84 | 04-FEB-02:00 |
| March | 0.105116E+12 | 68318.54 | 08-MAR-18:19 | 0.740594E+11 | 104220.80 | 05-MAR-01:10 |
| April | 0.990115E+11 | 65596.82 | 06-APR-19:30 | 0.287633E+11 | 60564.03 | 29-APR-04:00 |
| May | 0.102755E+12 | 75704.21 | 19-MAY-17:10 | 0.177321E+11 | 52142.40 | 08-MAY-08:09 |
| June | 0.107918E+12 | 83513.44 | 28-JUN-17:10 | 0.751051E+09 | 13173.91 | 17-JUN-03:00 |
| July | 0.122012E+12 | 87470.23 | 17-JUL-17:40 | 28425379.70 | 2011.22 | 09-JUL-03:39 |
| August | 0.117022E+12 | 86299.42 | 06-AUG-17:00 | 0.369629E+09 | 8150.64 | 18-AUG-04:00 |
| September | 0.103977E+12 | 86863.95 | 02-SEP-17:10 | 0.463097E+10 | 23357.16 | 19-SEP-02:00 |
| October | 0.996166E+11 | 68316.88 | 18-OCT-16:10 | 0.157995E+11 | 47197.77 | 10-OCT-07:10 |
| November | 0.984109E+11 | 63064.31 | 26-NOV-18:19 | 0.595541E+11 | 91311.95 | 27-NOV-04:00 |
| December | 0.106185E+12 | 69636.27 | 28-DEC-18:00 | 0.123517E+12 | 124317.52 | 31-DEC-08:09 |
| Annual Sum or Average | 0.126814E+13 | 0.586172E+12 | ||||
| Minimum of Months | 0.969842E+11 | 63064.31 | 28425379.70 | 2011.22 | ||
| Maximum of Months | 0.122012E+12 | 87470.23 | 0.165786E+12 | 141409.12 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.541675E+10 | 0.389380E+11 | 0.00 | 0.108469E+11 | 0.00 | 0.00 | 484391.98 | 0.00 | 0.00 | 0.00 | 0.455251E+11 | 0.00 |
| February | 0.760941E+10 | 0.447513E+10 | 0.351823E+11 | 0.00 | 0.782208E+10 | 0.00 | 0.00 | 0.215358E+09 | 0.00 | 0.00 | 0.00 | 0.416800E+11 | 0.00 |
| March | 0.845392E+10 | 0.437008E+10 | 0.389781E+11 | 0.00 | 0.744043E+10 | 0.00 | 0.00 | 0.105577E+09 | 0.00 | 0.00 | 0.00 | 0.457674E+11 | 0.00 |
| April | 0.814762E+10 | 0.363855E+10 | 0.376905E+11 | 0.00 | 0.578960E+10 | 0.00 | 0.00 | 0.781283E+09 | 0.00 | 0.00 | 0.00 | 0.429639E+11 | 0.00 |
| May | 0.843904E+10 | 0.323554E+10 | 0.389647E+11 | 0.00 | 0.631671E+10 | 0.00 | 0.00 | 0.340059E+10 | 0.00 | 0.00 | 0.00 | 0.423985E+11 | 0.00 |
| June | 0.817737E+10 | 0.285736E+10 | 0.377173E+11 | 0.00 | 0.809464E+10 | 0.00 | 0.00 | 0.121166E+11 | 0.00 | 0.00 | 0.00 | 0.389545E+11 | 0.00 |
| July | 0.840929E+10 | 0.307892E+10 | 0.389380E+11 | 0.00 | 0.110497E+11 | 0.00 | 0.00 | 0.218706E+11 | 0.00 | 0.00 | 0.00 | 0.386655E+11 | 0.00 |
| August | 0.845392E+10 | 0.352395E+10 | 0.389781E+11 | 0.00 | 0.996436E+10 | 0.00 | 0.00 | 0.181038E+11 | 0.00 | 0.00 | 0.00 | 0.379981E+11 | 0.00 |
| September | 0.814762E+10 | 0.397089E+10 | 0.376905E+11 | 0.00 | 0.743479E+10 | 0.00 | 0.00 | 0.950720E+10 | 0.00 | 0.00 | 0.00 | 0.372259E+11 | 0.00 |
| October | 0.842417E+10 | 0.471006E+10 | 0.389514E+11 | 0.00 | 0.575528E+10 | 0.00 | 0.00 | 0.185055E+10 | 0.00 | 0.00 | 0.00 | 0.399252E+11 | 0.00 |
| November | 0.814762E+10 | 0.509205E+10 | 0.376905E+11 | 0.00 | 0.676377E+10 | 0.00 | 0.00 | 0.121495E+09 | 0.00 | 0.00 | 0.00 | 0.405954E+11 | 0.00 |
| December | 0.840929E+10 | 0.556764E+10 | 0.389380E+11 | 0.00 | 0.929022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.439798E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.499369E+11 | 0.458657E+12 | 0.00 | 0.965684E+11 | 0.00 | 0.00 | 0.680735E+11 | 0.00 | 0.00 | 0.00 | 0.495679E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.285736E+10 | 0.351823E+11 | 0.00 | 0.575528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372259E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.556764E+10 | 0.389781E+11 | 0.00 | 0.110497E+11 | 0.00 | 0.00 | 0.218706E+11 | 0.00 | 0.00 | 0.00 | 0.457674E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.165786E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.951809E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.740594E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.287633E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.177321E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.751051E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 28425379.70 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.369629E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.463097E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.157995E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.595541E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.123517E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.586172E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 28425379.70 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.165786E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 7050.62 | 10-JAN-23:10 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 5724.37 | 04-FEB-02:00 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 5651.19 | 05-MAR-01:10 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 4052.69 | 29-APR-04:00 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 6117.59 | 20-MAY-16:10 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 7595.45 | 29-JUN-15:09 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 9196.14 | 17-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 8913.30 | 06-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 8588.53 | 02-SEP-15:09 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 5130.27 | 18-OCT-15:09 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 5195.09 | 27-NOV-04:00 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 6386.32 | 31-DEC-08:09 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 4052.69 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 9196.14 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 96.71 | 15-JAN-13:39 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 40913.84 | 11-JAN-07:30 | 0.00 |
| February | 3854.34 | 27-FEB-15:30 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 40847.86 | 11-FEB-07:30 | 0.00 |
| March | 2272.97 | 01-MAR-16:10 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 39784.73 | 13-MAR-06:40 | 0.00 |
| April | 5901.58 | 06-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 36570.36 | 07-APR-07:00 | 0.00 |
| May | 14919.13 | 20-MAY-16:10 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 34809.44 | 06-MAY-06:00 | 0.00 |
| June | 20732.72 | 29-JUN-15:09 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 32998.35 | 21-JUN-06:00 | 0.00 |
| July | 27058.21 | 17-JUL-15:00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 31350.94 | 30-JUL-05:40 | 0.00 |
| August | 25064.09 | 06-AUG-16:10 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 32784.56 | 09-AUG-06:40 | 0.00 |
| September | 24082.60 | 02-SEP-15:09 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 33883.26 | 10-SEP-07:19 | 0.00 |
| October | 11570.25 | 18-OCT-15:09 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 31611.94 | 16-OCT-06:40 | 0.00 |
| November | 3103.00 | 03-NOV-14:09 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 32874.13 | 09-NOV-07:19 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 35213.38 | 29-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 31350.94 | 0.00 | |||
| Maximum of Months | 27058.21 | 0.00 | 0.00 | 0.00 | 40913.84 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 74615.50 | 10-JAN-18:10 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 6016.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 69727.78 | 02-FEB-18:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 4053.53 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 68318.54 | 08-MAR-18:19 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2448.11 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65596.82 | 06-APR-19:30 | 5904.43 | 19801.20 | 3183.33 | 0.00 | 2365.30 | 0.00 | 0.00 | 2068.65 | 0.00 |
| May | 75704.21 | 19-MAY-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 5782.81 | 0.00 | 0.00 | 13345.32 | 0.00 |
| June | 83513.44 | 28-JUN-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7150.54 | 0.00 | 0.00 | 18137.90 | 0.00 |
| July | 87470.23 | 17-JUL-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8899.16 | 0.00 | 0.00 | 25204.16 | 0.00 |
| August | 86299.42 | 06-AUG-17:00 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8178.82 | 0.00 | 0.00 | 22274.43 | 0.00 |
| September | 86863.95 | 02-SEP-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8331.09 | 0.00 | 0.00 | 23128.29 | 0.00 |
| October | 68316.88 | 18-OCT-16:10 | 4289.87 | 22709.69 | 0.00 | 0.00 | 5029.18 | 0.00 | 0.00 | 10490.34 | 0.00 |
| November | 63064.31 | 26-NOV-18:19 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 4252.54 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 69636.27 | 28-DEC-18:00 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 5256.11 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 63064.31 | 4289.87 | 19801.20 | 0.00 | 0.00 | 2365.30 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 87470.23 | 5904.43 | 22709.69 | 3183.33 | 0.00 | 8899.16 | 0.00 | 0.00 | 25204.16 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 141409.12 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 105610.84 | 04-FEB-02:00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 104220.80 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 60564.03 | 29-APR-04:00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 52142.40 | 08-MAY-08:09 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 13173.91 | 17-JUN-03:00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 2011.22 | 09-JUL-03:39 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 8150.64 | 18-AUG-04:00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 23357.16 | 19-SEP-02:00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 47197.77 | 10-OCT-07:10 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 91311.95 | 27-NOV-04:00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 124317.52 | 31-DEC-08:09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 2011.22 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 141409.12 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 508.83 | 21.10 | 508.83 | 21.10 |
| February | 473.00 | 21.18 | 405.33 | 21.14 | 405.33 | 21.13 |
| March | 506.00 | 21.12 | 453.67 | 21.11 | 453.67 | 21.11 |
| April | 510.00 | 21.30 | 296.17 | 21.23 | 296.17 | 21.19 |
| May | 502.17 | 21.93 | 141.83 | 21.75 | 141.83 | 21.63 |
| June | 326.50 | 23.04 | 25.83 | 23.11 | 0.00 | 23.11 |
| July | 74.67 | 23.52 | 124.83 | 23.82 | 0.00 | 23.82 |
| August | 120.83 | 23.47 | 34.67 | 23.59 | 0.00 | 23.59 |
| September | 258.17 | 22.70 | 95.00 | 23.05 | 0.00 | 23.05 |
| October | 510.33 | 22.48 | 11.50 | 22.45 | 11.50 | 22.42 |
| November | 510.00 | 21.35 | 240.67 | 21.27 | 240.67 | 21.23 |
| December | 533.00 | 21.10 | 519.17 | 21.10 | 519.17 | 21.10 |
| Annual Sum or Average | 4857.67 | 21.70 | 2857.50 | 21.58 | 2577.17 | 21.46 |
| Minimum of Months | 74.67 | 21.10 | 11.50 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.52 | 519.17 | 23.82 | 519.17 | 23.82 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 671.33 | 21.10 | 671.33 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.15 | 601.17 | 21.13 | 601.17 | 21.12 |
| May | 744.00 | 21.70 | 265.00 | 21.55 | 265.00 | 21.45 |
| June | 530.50 | 23.01 | 16.83 | 23.04 | 0.00 | 23.04 |
| July | 155.17 | 23.61 | 111.33 | 23.77 | 0.00 | 23.77 |
| August | 339.17 | 23.54 | 15.67 | 23.56 | 0.00 | 23.56 |
| September | 499.67 | 22.35 | 60.00 | 22.53 | 3.33 | 22.54 |
| October | 744.00 | 21.61 | 123.00 | 21.54 | 123.00 | 21.49 |
| November | 720.00 | 21.11 | 554.67 | 21.11 | 554.67 | 21.11 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 7356.50 | 21.61 | 4651.00 | 21.46 | 4450.50 | 21.36 |
| Minimum of Months | 155.17 | 21.10 | 15.67 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.61 | 744.00 | 23.77 | 744.00 | 23.77 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 140.00 | 20.94 | 140.00 | 20.94 | 140.00 | 20.94 |
| February | 133.00 | 21.16 | 117.00 | 21.06 | 117.00 | 21.02 |
| March | 161.00 | 21.16 | 130.50 | 21.05 | 130.50 | 21.01 |
| April | 140.00 | 21.91 | 65.67 | 21.58 | 65.67 | 21.41 |
| May | 142.00 | 22.28 | 44.17 | 21.95 | 44.17 | 21.74 |
| June | 30.50 | 23.77 | 77.17 | 24.11 | 0.00 | 24.11 |
| July | 0.00 | 0.00 | 136.17 | 24.23 | 0.00 | 24.23 |
| August | 1.83 | 24.06 | 142.83 | 24.23 | 0.00 | 24.23 |
| September | 43.50 | 23.44 | 67.67 | 23.92 | 0.00 | 23.92 |
| October | 94.67 | 23.09 | 7.17 | 22.93 | 6.83 | 22.79 |
| November | 140.00 | 22.10 | 57.33 | 21.76 | 57.33 | 21.57 |
| December | 140.00 | 20.97 | 131.83 | 20.95 | 131.83 | 20.94 |
| Annual Sum or Average | 1166.50 | 21.77 | 1117.50 | 21.97 | 693.33 | 21.72 |
| Minimum of Months | 0.00 | 0.00 | 7.17 | 20.94 | 0.00 | 20.94 |
| Maximum of Months | 161.00 | 24.06 | 142.83 | 24.23 | 140.00 | 24.23 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.14 | 589.00 | 21.12 | 589.00 | 21.12 |
| May | 744.00 | 21.69 | 265.00 | 21.53 | 265.00 | 21.44 |
| June | 511.33 | 23.04 | 41.50 | 23.11 | 0.00 | 23.11 |
| July | 142.17 | 23.62 | 138.67 | 23.81 | 0.00 | 23.81 |
| August | 282.67 | 23.57 | 21.50 | 23.60 | 0.00 | 23.60 |
| September | 502.17 | 22.42 | 50.67 | 22.56 | 4.00 | 22.57 |
| October | 744.00 | 21.62 | 118.67 | 21.55 | 118.67 | 21.49 |
| November | 720.00 | 21.11 | 559.00 | 21.10 | 559.00 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 7270.33 | 21.59 | 4688.00 | 21.46 | 4439.67 | 21.36 |
| Minimum of Months | 142.17 | 21.10 | 21.50 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.62 | 744.00 | 23.81 | 744.00 | 23.81 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.14 | 527.83 | 21.13 | 527.83 | 21.12 |
| May | 744.00 | 21.74 | 221.00 | 21.59 | 221.00 | 21.50 |
| June | 540.67 | 23.29 | 7.17 | 23.30 | 0.00 | 23.30 |
| July | 126.17 | 23.77 | 70.83 | 23.85 | 0.00 | 23.85 |
| August | 339.33 | 23.77 | 0.00 | 23.77 | 0.00 | 23.77 |
| September | 515.50 | 22.63 | 55.33 | 22.76 | 3.83 | 22.77 |
| October | 744.00 | 21.79 | 46.17 | 21.75 | 46.17 | 21.71 |
| November | 720.00 | 21.13 | 457.17 | 21.12 | 457.17 | 21.12 |
| December | 744.00 | 21.10 | 734.00 | 21.10 | 734.00 | 21.10 |
| Annual Sum or Average | 7353.67 | 21.68 | 4279.50 | 21.50 | 4150.00 | 21.40 |
| Minimum of Months | 126.17 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.77 | 744.00 | 23.85 | 744.00 | 23.85 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.14 | 526.83 | 21.13 | 526.83 | 21.12 |
| May | 744.00 | 21.73 | 220.17 | 21.59 | 220.17 | 21.50 |
| June | 539.83 | 23.30 | 7.33 | 23.31 | 0.00 | 23.31 |
| July | 125.50 | 23.77 | 71.17 | 23.85 | 0.00 | 23.85 |
| August | 333.50 | 23.77 | 0.00 | 23.77 | 0.00 | 23.77 |
| September | 515.67 | 22.64 | 55.33 | 22.77 | 3.83 | 22.78 |
| October | 744.00 | 21.79 | 46.00 | 21.75 | 46.00 | 21.72 |
| November | 720.00 | 21.13 | 457.17 | 21.12 | 457.17 | 21.11 |
| December | 744.00 | 21.10 | 733.83 | 21.10 | 733.83 | 21.10 |
| Annual Sum or Average | 7346.50 | 21.68 | 4277.83 | 21.50 | 4147.83 | 21.39 |
| Minimum of Months | 125.50 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.77 | 744.00 | 23.85 | 744.00 | 23.85 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.12 | 456.83 | 21.11 | 456.83 | 21.11 |
| February | 473.00 | 21.24 | 347.50 | 21.18 | 347.50 | 21.16 |
| March | 506.00 | 21.15 | 382.67 | 21.13 | 382.67 | 21.12 |
| April | 510.00 | 21.38 | 173.17 | 21.31 | 173.17 | 21.27 |
| May | 503.67 | 22.05 | 101.00 | 21.89 | 101.00 | 21.78 |
| June | 309.33 | 23.35 | 22.33 | 23.40 | 0.00 | 23.40 |
| July | 62.83 | 23.75 | 93.50 | 23.90 | 0.00 | 23.90 |
| August | 79.67 | 23.70 | 10.33 | 23.74 | 0.00 | 23.74 |
| September | 233.17 | 23.09 | 84.83 | 23.33 | 0.00 | 23.33 |
| October | 503.67 | 22.89 | 2.00 | 22.88 | 2.00 | 22.87 |
| November | 510.00 | 21.66 | 152.33 | 21.53 | 152.33 | 21.45 |
| December | 533.00 | 21.10 | 444.67 | 21.10 | 444.67 | 21.10 |
| Annual Sum or Average | 4757.33 | 21.82 | 2271.17 | 21.68 | 2060.17 | 21.55 |
| Minimum of Months | 62.83 | 21.10 | 2.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.75 | 456.83 | 23.90 | 456.83 | 23.90 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.12 | 472.33 | 21.11 | 472.33 | 21.11 |
| February | 473.00 | 21.22 | 366.17 | 21.17 | 366.17 | 21.15 |
| March | 506.00 | 21.14 | 407.83 | 21.12 | 407.83 | 21.11 |
| April | 510.00 | 21.37 | 188.50 | 21.30 | 188.50 | 21.26 |
| May | 502.17 | 22.07 | 123.17 | 21.88 | 123.17 | 21.75 |
| June | 283.83 | 23.38 | 26.17 | 23.43 | 0.00 | 23.43 |
| July | 54.00 | 23.78 | 124.17 | 23.93 | 0.00 | 23.93 |
| August | 61.50 | 23.71 | 21.00 | 23.79 | 0.00 | 23.79 |
| September | 221.00 | 23.14 | 102.00 | 23.41 | 0.00 | 23.41 |
| October | 495.33 | 22.90 | 2.83 | 22.89 | 2.83 | 22.88 |
| November | 510.00 | 21.67 | 163.00 | 21.53 | 163.00 | 21.45 |
| December | 533.00 | 21.10 | 472.17 | 21.10 | 472.17 | 21.10 |
| Annual Sum or Average | 4682.83 | 21.80 | 2469.33 | 21.67 | 2196.00 | 21.54 |
| Minimum of Months | 54.00 | 21.10 | 2.83 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.78 | 472.33 | 23.93 | 472.33 | 23.93 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.16 | 409.83 | 21.13 | 409.83 | 21.12 |
| February | 473.00 | 21.39 | 255.17 | 21.29 | 255.17 | 21.24 |
| March | 506.00 | 21.37 | 202.33 | 21.30 | 202.33 | 21.25 |
| April | 501.83 | 22.16 | 48.17 | 22.07 | 48.17 | 21.99 |
| May | 366.67 | 22.39 | 33.67 | 22.35 | 23.33 | 22.29 |
| June | 160.67 | 23.41 | 84.50 | 23.61 | 0.00 | 23.61 |
| July | 36.83 | 23.65 | 170.83 | 23.94 | 0.00 | 23.94 |
| August | 75.17 | 23.53 | 51.33 | 23.72 | 0.00 | 23.72 |
| September | 234.83 | 22.79 | 88.67 | 23.12 | 0.00 | 23.12 |
| October | 490.83 | 22.59 | 5.67 | 22.57 | 5.67 | 22.55 |
| November | 510.00 | 21.55 | 170.67 | 21.44 | 170.67 | 21.37 |
| December | 533.00 | 21.11 | 433.50 | 21.10 | 433.50 | 21.10 |
| Annual Sum or Average | 4421.83 | 21.85 | 1954.33 | 21.81 | 1548.67 | 21.67 |
| Minimum of Months | 36.83 | 21.11 | 5.67 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.65 | 433.50 | 23.94 | 433.50 | 23.94 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 714.00 | 21.10 | 714.00 | 21.10 |
| February | 672.00 | 21.13 | 593.67 | 21.12 | 593.67 | 21.11 |
| March | 744.00 | 21.14 | 543.67 | 21.12 | 543.67 | 21.12 |
| April | 720.00 | 21.70 | 96.67 | 21.63 | 96.67 | 21.57 |
| May | 603.00 | 22.25 | 45.83 | 22.19 | 42.83 | 22.12 |
| June | 252.50 | 23.49 | 88.00 | 23.62 | 0.00 | 23.62 |
| July | 56.50 | 23.72 | 170.17 | 23.93 | 0.00 | 23.93 |
| August | 168.00 | 23.56 | 26.17 | 23.62 | 0.00 | 23.62 |
| September | 451.50 | 22.46 | 58.33 | 22.64 | 2.50 | 22.65 |
| October | 744.00 | 21.87 | 68.50 | 21.81 | 68.50 | 21.75 |
| November | 720.00 | 21.14 | 459.00 | 21.13 | 459.00 | 21.12 |
| December | 744.00 | 21.10 | 705.00 | 21.10 | 705.00 | 21.10 |
| Annual Sum or Average | 6619.50 | 21.64 | 3569.00 | 21.55 | 3225.83 | 21.44 |
| Minimum of Months | 56.50 | 21.10 | 26.17 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.72 | 714.00 | 23.93 | 714.00 | 23.93 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.17 | 406.83 | 21.14 | 406.83 | 21.13 |
| February | 473.00 | 21.40 | 258.00 | 21.30 | 258.00 | 21.25 |
| March | 506.00 | 21.36 | 203.33 | 21.29 | 203.33 | 21.25 |
| April | 500.67 | 22.18 | 54.17 | 22.08 | 54.17 | 21.99 |
| May | 377.67 | 22.37 | 34.00 | 22.31 | 27.67 | 22.24 |
| June | 170.17 | 23.45 | 90.17 | 23.64 | 0.00 | 23.64 |
| July | 39.00 | 23.63 | 162.50 | 23.93 | 0.00 | 23.93 |
| August | 75.00 | 23.56 | 48.33 | 23.73 | 0.00 | 23.73 |
| September | 233.00 | 22.81 | 84.00 | 23.13 | 0.00 | 23.13 |
| October | 494.33 | 22.59 | 6.50 | 22.57 | 6.50 | 22.55 |
| November | 510.00 | 21.54 | 171.83 | 21.43 | 171.83 | 21.36 |
| December | 533.00 | 21.11 | 433.83 | 21.10 | 433.83 | 21.10 |
| Annual Sum or Average | 4444.83 | 21.86 | 1953.50 | 21.81 | 1562.17 | 21.67 |
| Minimum of Months | 39.00 | 21.11 | 6.50 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.63 | 433.83 | 23.93 | 433.83 | 23.93 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 722.17 | 21.10 | 722.17 | 21.10 |
| February | 672.00 | 21.12 | 592.83 | 21.11 | 592.83 | 21.11 |
| March | 744.00 | 21.13 | 522.00 | 21.12 | 522.00 | 21.11 |
| April | 720.00 | 21.78 | 107.83 | 21.69 | 107.83 | 21.62 |
| May | 609.83 | 22.30 | 41.50 | 22.23 | 41.50 | 22.16 |
| June | 245.00 | 23.53 | 109.50 | 23.68 | 0.00 | 23.68 |
| July | 54.17 | 23.66 | 191.00 | 23.92 | 0.00 | 23.92 |
| August | 135.83 | 23.55 | 30.33 | 23.64 | 0.00 | 23.64 |
| September | 438.33 | 22.50 | 52.33 | 22.66 | 3.00 | 22.67 |
| October | 744.00 | 21.88 | 56.33 | 21.82 | 56.33 | 21.78 |
| November | 720.00 | 21.13 | 452.83 | 21.12 | 452.83 | 21.11 |
| December | 744.00 | 21.10 | 709.17 | 21.10 | 709.17 | 21.10 |
| Annual Sum or Average | 6571.17 | 21.64 | 3587.83 | 21.56 | 3207.67 | 21.45 |
| Minimum of Months | 54.17 | 21.10 | 30.33 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.66 | 722.17 | 23.92 | 722.17 | 23.92 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 661.50 | 21.10 | 661.50 | 21.10 |
| February | 672.00 | 21.13 | 459.50 | 21.12 | 459.50 | 21.11 |
| March | 744.00 | 21.14 | 344.50 | 21.13 | 344.50 | 21.12 |
| April | 720.00 | 21.77 | 70.50 | 21.71 | 70.50 | 21.66 |
| May | 610.50 | 22.33 | 9.17 | 22.31 | 9.17 | 22.30 |
| June | 272.33 | 23.75 | 50.33 | 23.79 | 0.00 | 23.79 |
| July | 64.00 | 23.90 | 85.50 | 23.96 | 0.00 | 23.96 |
| August | 157.50 | 23.80 | 0.00 | 23.80 | 0.00 | 23.80 |
| September | 448.83 | 22.75 | 50.83 | 22.88 | 3.33 | 22.88 |
| October | 744.00 | 22.17 | 20.00 | 22.14 | 20.00 | 22.11 |
| November | 720.00 | 21.21 | 370.17 | 21.17 | 370.17 | 21.15 |
| December | 744.00 | 21.10 | 651.17 | 21.10 | 651.17 | 21.10 |
| Annual Sum or Average | 6641.17 | 21.74 | 2773.17 | 21.61 | 2589.83 | 21.50 |
| Minimum of Months | 64.00 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.90 | 661.50 | 23.96 | 661.50 | 23.96 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 660.50 | 21.10 | 660.50 | 21.10 |
| February | 672.00 | 21.13 | 459.83 | 21.12 | 459.83 | 21.11 |
| March | 744.00 | 21.14 | 343.50 | 21.13 | 343.50 | 21.12 |
| April | 720.00 | 21.79 | 71.17 | 21.72 | 71.17 | 21.67 |
| May | 610.67 | 22.34 | 9.50 | 22.32 | 9.50 | 22.30 |
| June | 271.50 | 23.75 | 51.00 | 23.79 | 0.00 | 23.79 |
| July | 64.83 | 23.90 | 85.67 | 23.96 | 0.00 | 23.96 |
| August | 154.83 | 23.80 | 0.00 | 23.80 | 0.00 | 23.80 |
| September | 447.50 | 22.75 | 50.83 | 22.88 | 3.33 | 22.89 |
| October | 744.00 | 22.17 | 19.00 | 22.14 | 19.00 | 22.12 |
| November | 720.00 | 21.21 | 371.33 | 21.17 | 371.33 | 21.15 |
| December | 744.00 | 21.10 | 651.17 | 21.10 | 651.17 | 21.10 |
| Annual Sum or Average | 6637.33 | 21.74 | 2773.50 | 21.61 | 2589.33 | 21.50 |
| Minimum of Months | 64.83 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.90 | 660.50 | 23.96 | 660.50 | 23.96 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.27 | 334.67 | 21.21 | 334.67 | 21.18 |
| February | 473.00 | 21.56 | 169.83 | 21.44 | 169.83 | 21.37 |
| March | 506.00 | 21.59 | 86.50 | 21.52 | 86.50 | 21.47 |
| April | 505.67 | 22.50 | 20.00 | 22.45 | 20.00 | 22.40 |
| May | 368.00 | 22.52 | 8.83 | 22.51 | 6.67 | 22.48 |
| June | 164.67 | 23.70 | 53.83 | 23.77 | 0.00 | 23.77 |
| July | 35.67 | 23.85 | 111.33 | 23.96 | 0.00 | 23.96 |
| August | 55.17 | 23.76 | 10.83 | 23.80 | 0.00 | 23.80 |
| September | 212.17 | 23.19 | 77.67 | 23.41 | 0.00 | 23.41 |
| October | 471.17 | 23.02 | 0.00 | 23.02 | 0.00 | 23.02 |
| November | 509.33 | 21.99 | 94.00 | 21.85 | 94.00 | 21.75 |
| December | 533.00 | 21.17 | 304.00 | 21.14 | 304.00 | 21.13 |
| Annual Sum or Average | 4366.83 | 22.08 | 1271.50 | 21.99 | 1015.67 | 21.86 |
| Minimum of Months | 35.67 | 21.17 | 0.00 | 21.14 | 0.00 | 21.13 |
| Maximum of Months | 533.00 | 23.85 | 334.67 | 23.96 | 334.67 | 23.96 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.28 | 334.50 | 21.21 | 334.50 | 21.18 |
| February | 473.00 | 21.56 | 169.83 | 21.44 | 169.83 | 21.37 |
| March | 506.00 | 21.60 | 86.50 | 21.52 | 86.50 | 21.47 |
| April | 505.33 | 22.50 | 19.50 | 22.45 | 19.50 | 22.40 |
| May | 367.83 | 22.52 | 9.00 | 22.50 | 6.83 | 22.48 |
| June | 164.00 | 23.70 | 55.83 | 23.77 | 0.00 | 23.77 |
| July | 36.17 | 23.85 | 112.17 | 23.96 | 0.00 | 23.96 |
| August | 55.00 | 23.77 | 10.83 | 23.80 | 0.00 | 23.80 |
| September | 211.83 | 23.20 | 77.33 | 23.41 | 0.00 | 23.41 |
| October | 471.17 | 23.01 | 0.00 | 23.01 | 0.00 | 23.01 |
| November | 509.33 | 21.99 | 94.00 | 21.85 | 94.00 | 21.75 |
| December | 533.00 | 21.17 | 303.50 | 21.14 | 303.50 | 21.13 |
| Annual Sum or Average | 4365.67 | 22.08 | 1273.00 | 22.00 | 1014.67 | 21.86 |
| Minimum of Months | 36.17 | 21.17 | 0.00 | 21.14 | 0.00 | 21.13 |
| Maximum of Months | 533.00 | 23.85 | 334.50 | 23.96 | 334.50 | 23.96 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.14 | 488.83 | 21.12 | 488.83 | 21.11 |
| February | 465.67 | 21.27 | 379.33 | 21.19 | 379.33 | 21.16 |
| March | 502.17 | 21.30 | 393.83 | 21.21 | 393.83 | 21.18 |
| April | 470.83 | 21.63 | 234.33 | 21.47 | 229.83 | 21.38 |
| May | 402.83 | 21.96 | 146.00 | 21.84 | 124.67 | 21.71 |
| June | 257.17 | 22.48 | 115.17 | 22.89 | 7.00 | 22.86 |
| July | 165.17 | 22.94 | 193.50 | 23.51 | 0.00 | 23.51 |
| August | 227.83 | 23.02 | 111.83 | 23.29 | 6.67 | 23.25 |
| September | 304.83 | 22.17 | 135.50 | 22.45 | 42.83 | 22.33 |
| October | 488.67 | 21.70 | 157.17 | 21.57 | 154.33 | 21.48 |
| November | 508.67 | 21.28 | 351.50 | 21.21 | 351.50 | 21.18 |
| December | 533.00 | 21.10 | 504.17 | 21.10 | 504.17 | 21.10 |
| Annual Sum or Average | 4859.83 | 21.64 | 3211.17 | 21.61 | 2683.00 | 21.49 |
| Minimum of Months | 165.17 | 21.10 | 111.83 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.02 | 504.17 | 23.51 | 504.17 | 23.51 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 742.17 | 21.10 | 742.17 | 21.10 |
| February | 672.00 | 21.13 | 629.67 | 21.12 | 629.67 | 21.11 |
| March | 744.00 | 21.15 | 649.33 | 21.13 | 649.33 | 21.12 |
| April | 704.17 | 21.53 | 367.00 | 21.38 | 367.00 | 21.31 |
| May | 621.17 | 21.95 | 212.33 | 21.81 | 190.17 | 21.68 |
| June | 350.00 | 22.51 | 163.00 | 22.96 | 5.50 | 22.94 |
| July | 205.17 | 23.01 | 283.17 | 23.58 | 0.00 | 23.58 |
| August | 329.50 | 22.93 | 149.83 | 23.23 | 6.50 | 23.20 |
| September | 511.00 | 22.08 | 165.67 | 22.23 | 78.83 | 22.12 |
| October | 742.17 | 21.48 | 326.33 | 21.37 | 326.33 | 21.30 |
| November | 720.00 | 21.11 | 615.00 | 21.11 | 615.00 | 21.10 |
| December | 744.00 | 21.10 | 738.33 | 21.10 | 738.33 | 21.10 |
| Annual Sum or Average | 7087.17 | 21.55 | 5041.83 | 21.53 | 4348.83 | 21.42 |
| Minimum of Months | 205.17 | 21.10 | 149.83 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.01 | 742.17 | 23.58 | 742.17 | 23.58 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.15 | 488.17 | 21.13 | 488.17 | 21.12 |
| February | 464.83 | 21.27 | 380.50 | 21.19 | 380.50 | 21.16 |
| March | 504.83 | 21.29 | 398.17 | 21.21 | 398.17 | 21.18 |
| April | 477.67 | 21.67 | 231.17 | 21.48 | 231.17 | 21.39 |
| May | 419.00 | 21.99 | 152.33 | 21.86 | 131.00 | 21.72 |
| June | 257.00 | 22.53 | 104.00 | 22.90 | 6.67 | 22.87 |
| July | 162.00 | 23.01 | 188.50 | 23.54 | 0.00 | 23.54 |
| August | 227.00 | 23.04 | 97.00 | 23.28 | 5.17 | 23.24 |
| September | 304.33 | 22.19 | 130.83 | 22.46 | 41.17 | 22.34 |
| October | 493.17 | 21.72 | 160.33 | 21.58 | 157.67 | 21.49 |
| November | 510.00 | 21.27 | 354.33 | 21.20 | 354.33 | 21.17 |
| December | 533.00 | 21.10 | 502.50 | 21.10 | 502.50 | 21.10 |
| Annual Sum or Average | 4885.83 | 21.65 | 3187.83 | 21.61 | 2696.50 | 21.48 |
| Minimum of Months | 162.00 | 21.10 | 97.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.04 | 502.50 | 23.54 | 502.50 | 23.54 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.12 | 633.33 | 21.11 | 633.33 | 21.11 |
| March | 744.00 | 21.13 | 637.17 | 21.11 | 637.17 | 21.11 |
| April | 717.33 | 21.64 | 353.50 | 21.46 | 353.50 | 21.37 |
| May | 625.00 | 22.02 | 201.33 | 21.87 | 181.17 | 21.73 |
| June | 328.33 | 22.61 | 183.33 | 23.07 | 6.67 | 23.05 |
| July | 183.00 | 23.01 | 319.17 | 23.64 | 0.00 | 23.64 |
| August | 293.83 | 22.97 | 152.50 | 23.29 | 5.17 | 23.26 |
| September | 504.50 | 22.13 | 153.17 | 22.27 | 69.50 | 22.17 |
| October | 744.00 | 21.46 | 321.67 | 21.35 | 321.67 | 21.29 |
| November | 720.00 | 21.10 | 621.33 | 21.10 | 621.33 | 21.10 |
| December | 744.00 | 21.10 | 740.67 | 21.10 | 740.67 | 21.10 |
| Annual Sum or Average | 7020.00 | 21.55 | 5061.17 | 21.54 | 4314.17 | 21.43 |
| Minimum of Months | 183.00 | 21.10 | 152.50 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.01 | 744.00 | 23.64 | 744.00 | 23.64 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 742.00 | 21.10 | 742.00 | 21.10 |
| February | 672.00 | 21.11 | 637.50 | 21.11 | 637.50 | 21.11 |
| March | 744.00 | 21.13 | 652.00 | 21.11 | 652.00 | 21.11 |
| April | 720.00 | 21.57 | 312.33 | 21.43 | 312.33 | 21.35 |
| May | 644.50 | 22.09 | 170.33 | 21.93 | 156.00 | 21.80 |
| June | 360.67 | 22.87 | 105.67 | 23.12 | 1.33 | 23.12 |
| July | 183.00 | 23.28 | 186.00 | 23.64 | 0.00 | 23.64 |
| August | 319.00 | 23.20 | 51.83 | 23.31 | 0.00 | 23.31 |
| September | 508.17 | 22.19 | 107.83 | 22.31 | 46.00 | 22.24 |
| October | 744.00 | 21.51 | 249.50 | 21.41 | 249.50 | 21.34 |
| November | 720.00 | 21.12 | 575.50 | 21.11 | 575.50 | 21.11 |
| December | 744.00 | 21.10 | 730.83 | 21.10 | 730.83 | 21.10 |
| Annual Sum or Average | 7103.33 | 21.60 | 4521.33 | 21.51 | 4103.00 | 21.41 |
| Minimum of Months | 183.00 | 21.10 | 51.83 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.28 | 742.00 | 23.64 | 742.00 | 23.64 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 741.50 | 21.10 | 741.50 | 21.10 |
| February | 672.00 | 21.11 | 637.50 | 21.11 | 637.50 | 21.10 |
| March | 744.00 | 21.13 | 651.17 | 21.11 | 651.17 | 21.11 |
| April | 720.00 | 21.58 | 310.17 | 21.43 | 310.17 | 21.36 |
| May | 642.00 | 22.09 | 170.67 | 21.93 | 156.50 | 21.80 |
| June | 358.83 | 22.88 | 108.00 | 23.13 | 1.33 | 23.13 |
| July | 181.83 | 23.28 | 188.67 | 23.65 | 0.00 | 23.65 |
| August | 317.17 | 23.20 | 52.33 | 23.31 | 0.00 | 23.31 |
| September | 507.17 | 22.20 | 107.50 | 22.32 | 45.50 | 22.25 |
| October | 744.00 | 21.51 | 251.67 | 21.40 | 251.67 | 21.34 |
| November | 720.00 | 21.12 | 576.17 | 21.11 | 576.17 | 21.11 |
| December | 744.00 | 21.10 | 731.00 | 21.10 | 731.00 | 21.10 |
| Annual Sum or Average | 7095.00 | 21.60 | 4526.33 | 21.51 | 4102.50 | 21.41 |
| Minimum of Months | 181.83 | 21.10 | 52.33 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.28 | 741.50 | 23.65 | 741.50 | 23.65 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.19 | 459.67 | 21.15 | 459.67 | 21.13 |
| February | 465.50 | 21.35 | 346.00 | 21.24 | 346.00 | 21.20 |
| March | 505.33 | 21.38 | 354.00 | 21.26 | 354.00 | 21.22 |
| April | 485.83 | 21.83 | 172.17 | 21.64 | 172.17 | 21.53 |
| May | 417.50 | 22.20 | 108.17 | 22.04 | 95.83 | 21.89 |
| June | 255.50 | 22.81 | 80.00 | 23.07 | 2.33 | 23.06 |
| July | 147.67 | 23.23 | 155.33 | 23.62 | 0.00 | 23.62 |
| August | 205.67 | 23.28 | 71.33 | 23.46 | 0.00 | 23.46 |
| September | 287.17 | 22.38 | 102.00 | 22.67 | 17.17 | 22.61 |
| October | 490.67 | 21.95 | 89.83 | 21.82 | 89.17 | 21.73 |
| November | 509.17 | 21.41 | 298.67 | 21.30 | 298.67 | 21.24 |
| December | 533.00 | 21.12 | 482.50 | 21.11 | 482.50 | 21.11 |
| Annual Sum or Average | 4836.00 | 21.78 | 2719.67 | 21.69 | 2317.50 | 21.55 |
| Minimum of Months | 147.67 | 21.12 | 71.33 | 21.11 | 0.00 | 21.11 |
| Maximum of Months | 533.00 | 23.28 | 482.50 | 23.62 | 482.50 | 23.62 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.19 | 459.50 | 21.15 | 459.50 | 21.13 |
| February | 465.33 | 21.35 | 345.50 | 21.24 | 345.50 | 21.20 |
| March | 505.33 | 21.38 | 355.00 | 21.26 | 355.00 | 21.22 |
| April | 485.00 | 21.83 | 172.83 | 21.64 | 172.83 | 21.52 |
| May | 418.67 | 22.20 | 108.67 | 22.04 | 96.17 | 21.89 |
| June | 255.17 | 22.80 | 80.33 | 23.07 | 2.33 | 23.06 |
| July | 147.17 | 23.23 | 154.33 | 23.62 | 0.00 | 23.62 |
| August | 206.33 | 23.28 | 71.00 | 23.46 | 0.00 | 23.46 |
| September | 286.83 | 22.38 | 102.00 | 22.67 | 17.17 | 22.61 |
| October | 490.33 | 21.95 | 89.83 | 21.82 | 89.17 | 21.72 |
| November | 509.17 | 21.41 | 299.00 | 21.30 | 299.00 | 21.24 |
| December | 533.00 | 21.12 | 482.50 | 21.11 | 482.50 | 21.11 |
| Annual Sum or Average | 4835.33 | 21.78 | 2720.50 | 21.69 | 2319.17 | 21.55 |
| Minimum of Months | 147.17 | 21.12 | 71.00 | 21.11 | 0.00 | 21.11 |
| Maximum of Months | 533.00 | 23.28 | 482.50 | 23.62 | 482.50 | 23.62 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 19.33 | 618.67 | 19.18 | 618.67 | 19.13 |
| February | 672.00 | 20.32 | 405.67 | 20.01 | 405.67 | 19.87 |
| March | 744.00 | 20.85 | 243.33 | 20.58 | 243.33 | 20.41 |
| April | 661.00 | 21.91 | 355.33 | 22.08 | 328.50 | 22.11 |
| May | 706.67 | 23.14 | 482.00 | 23.47 | 452.17 | 23.58 |
| June | 702.50 | 24.99 | 706.17 | 25.01 | 692.33 | 25.01 |
| July | 737.67 | 25.78 | 744.00 | 25.78 | 737.67 | 25.78 |
| August | 735.50 | 25.42 | 729.83 | 25.45 | 722.17 | 25.46 |
| September | 669.33 | 23.99 | 542.50 | 24.30 | 506.33 | 24.40 |
| October | 663.67 | 21.95 | 432.83 | 22.09 | 385.17 | 22.07 |
| November | 720.00 | 20.79 | 240.17 | 20.51 | 240.17 | 20.34 |
| December | 744.00 | 19.74 | 611.67 | 19.62 | 611.67 | 19.58 |
| Annual Sum or Average | 8500.33 | 22.34 | 6112.17 | 22.52 | 5943.83 | 22.57 |
| Minimum of Months | 661.00 | 19.33 | 240.17 | 19.18 | 240.17 | 19.13 |
| Maximum of Months | 744.00 | 25.78 | 744.00 | 25.78 | 737.67 | 25.78 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 15.71 | 744.00 | 15.71 | 744.00 | 15.71 |
| February | 672.00 | 17.18 | 651.67 | 17.11 | 651.67 | 17.09 |
| March | 744.00 | 17.95 | 729.67 | 17.92 | 729.67 | 17.91 |
| April | 720.00 | 19.56 | 496.67 | 19.22 | 496.67 | 19.08 |
| May | 700.50 | 20.75 | 310.00 | 20.22 | 298.83 | 19.89 |
| June | 346.83 | 23.00 | 304.83 | 24.13 | 68.33 | 24.13 |
| July | 190.17 | 25.39 | 649.50 | 25.98 | 143.67 | 26.04 |
| August | 165.00 | 23.99 | 557.67 | 25.53 | 69.33 | 25.59 |
| September | 451.33 | 22.71 | 310.83 | 23.68 | 109.17 | 23.70 |
| October | 722.50 | 21.38 | 184.17 | 20.84 | 179.67 | 20.46 |
| November | 720.00 | 19.05 | 511.00 | 18.63 | 511.00 | 18.46 |
| December | 744.00 | 16.84 | 742.50 | 16.83 | 742.50 | 16.83 |
| Annual Sum or Average | 6920.33 | 19.35 | 6192.50 | 19.61 | 4744.50 | 19.20 |
| Minimum of Months | 165.00 | 15.71 | 184.17 | 15.71 | 68.33 | 15.71 |
| Maximum of Months | 744.00 | 25.39 | 744.00 | 25.98 | 744.00 | 26.04 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.19 | 61.67 | 21.25 | 61.67 | 21.30 |
| February | 663.00 | 21.81 | 48.83 | 21.87 | 48.83 | 21.92 |
| March | 744.00 | 22.27 | 333.00 | 22.31 | 333.00 | 22.32 |
| April | 711.17 | 23.35 | 637.50 | 23.39 | 631.33 | 23.40 |
| May | 735.17 | 24.12 | 631.00 | 24.24 | 631.00 | 24.28 |
| June | 718.00 | 25.70 | 720.00 | 25.70 | 718.00 | 25.70 |
| July | 744.00 | 26.04 | 744.00 | 26.04 | 744.00 | 26.04 |
| August | 744.00 | 25.88 | 744.00 | 25.88 | 744.00 | 25.88 |
| September | 698.83 | 24.98 | 715.83 | 24.98 | 696.83 | 24.98 |
| October | 728.17 | 23.79 | 666.17 | 23.83 | 664.83 | 23.85 |
| November | 715.67 | 22.34 | 356.17 | 22.46 | 356.17 | 22.52 |
| December | 744.00 | 21.43 | 203.83 | 21.37 | 203.83 | 21.33 |
| Annual Sum or Average | 8690.00 | 23.58 | 5862.00 | 23.95 | 5833.50 | 24.10 |
| Minimum of Months | 663.00 | 21.19 | 48.83 | 21.25 | 48.83 | 21.30 |
| Maximum of Months | 744.00 | 26.04 | 744.00 | 26.04 | 744.00 | 26.04 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 617425.41 | 165617.14 | 1.67 | 617425.41 | -0.0 | 0.00 | 0.03 | 06-APR-16:20 | 0.00 | 01-APR-00:10 | 145.23 | 06-APR-16:20 | 145.23 | 06-APR-16:20 | 0.00 | 06-APR-16:30 | 38.92 | 06-APR-16:20 | 0.00 | 01-APR-00:10 |
| May | 0.110944E+09 | 29724490.76 | 67.78 | 0.110910E+09 | 34477.17 | 0.00 | 0.21 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 | 1145.33 | 20-MAY-16:05 | 1145.33 | 20-MAY-16:05 | 5.05 | 20-MAY-11:50 | 322.34 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.882453E+09 | 0.234871E+09 | 336.94 | 0.857955E+09 | 24498859.93 | 0.00 | 0.37 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 | 2017.30 | 30-JUN-17:30 | 2017.30 | 30-JUN-17:30 | 216.19 | 20-JUN-19:00 | 571.01 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.231771E+10 | 0.620678E+09 | 634.11 | 0.226211E+10 | 55598004.15 | 0.00 | 0.54 | 17-JUL-16:10 | 0.00 | 02-JUL-06:30 | 2867.69 | 17-JUL-17:16 | 2867.69 | 17-JUL-17:16 | 247.87 | 18-JUL-21:05 | 856.06 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.207112E+10 | 0.554420E+09 | 589.80 | 0.206535E+10 | 5770779.77 | 0.00 | 0.53 | 06-AUG-16:02 | 0.00 | 01-AUG-22:40 | 2805.15 | 06-AUG-16:10 | 2805.15 | 06-AUG-16:10 | 63.75 | 01-AUG-14:30 | 822.90 | 06-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.127505E+10 | 0.335778E+09 | 384.08 | 0.123641E+10 | 38636854.22 | 0.00 | 0.54 | 02-SEP-15:20 | 0.00 | 08-SEP-08:55 | 2962.33 | 02-SEP-16:05 | 2962.33 | 02-SEP-16:05 | 565.02 | 07-SEP-15:10 | 846.17 | 02-SEP-16:50 | 0.00 | 01-SEP-00:10 |
| October | 0.229975E+09 | 60675923.29 | 131.24 | 0.229975E+09 | -0.0 | 0.00 | 0.34 | 18-OCT-15:30 | 0.00 | 01-OCT-00:10 | 1892.09 | 18-OCT-16:10 | 1892.09 | 18-OCT-16:10 | 0.00 | 18-OCT-15:10 | 489.65 | 18-OCT-15:20 | 0.00 | 01-OCT-00:10 |
| November | 103011.26 | 27668.49 | 0.83 | 103011.26 | 0.00 | 0.00 | 0.01 | 03-NOV-15:20 | 0.00 | 01-NOV-00:10 | 55.29 | 03-NOV-15:20 | 55.29 | 03-NOV-15:20 | 0.00 | 03-NOV-15:20 | 14.84 | 03-NOV-15:20 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.688797E+10 | 0.183634E+10 | 2146.44 | 0.676343E+10 | 0.124539E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.231771E+10 | 0.620678E+09 | 634.11 | 0.226211E+10 | 55598004.15 | 0.00 | 0.54 | 0.00 | 2962.33 | 2962.33 | 565.02 | 856.06 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 39553411.61 | 10699814.75 | 32.17 | 39553411.61 | -0.0 | 0.00 | 0.16 | 31-MAY-18:00 | 0.00 | 01-MAY-00:10 | 778.73 | 31-MAY-18:00 | 778.73 | 31-MAY-18:00 | 0.00 | 20-MAY-16:05 | 216.84 | 20-MAY-16:03 | 0.00 | 01-MAY-00:10 |
| June | 0.644490E+09 | 0.172194E+09 | 279.34 | 0.624712E+09 | 19778514.98 | 0.00 | 0.37 | 28-JUN-18:00 | 0.00 | 01-JUN-00:10 | 1824.20 | 28-JUN-18:00 | 1824.20 | 28-JUN-18:00 | 200.19 | 20-JUN-18:00 | 506.20 | 28-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.182092E+10 | 0.490013E+09 | 597.04 | 0.177312E+10 | 47801999.12 | 0.00 | 0.52 | 17-JUL-17:50 | 0.00 | 01-JUL-06:13 | 2569.76 | 17-JUL-17:50 | 2569.76 | 17-JUL-17:50 | 221.17 | 18-JUL-21:05 | 759.40 | 17-JUL-17:50 | 0.00 | 01-JUL-00:10 |
| August | 0.135071E+10 | 0.366020E+09 | 506.78 | 0.134682E+10 | 3882010.18 | 0.00 | 0.48 | 06-AUG-16:40 | 0.00 | 01-AUG-07:35 | 2322.48 | 06-AUG-16:40 | 2322.48 | 06-AUG-16:40 | 49.30 | 01-AUG-14:30 | 683.85 | 06-AUG-16:30 | 0.00 | 01-AUG-00:10 |
| September | 0.650739E+09 | 0.173730E+09 | 258.57 | 0.621161E+09 | 29577145.09 | 0.00 | 0.44 | 02-SEP-17:00 | 0.00 | 01-SEP-05:05 | 2176.06 | 04-SEP-17:07 | 2176.06 | 04-SEP-17:07 | 483.48 | 07-SEP-15:10 | 625.37 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 2442849.84 | 657849.41 | 3.75 | 2442849.84 | 0.00 | 0.00 | 0.07 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 362.14 | 18-OCT-16:05 | 362.14 | 18-OCT-16:05 | 0.00 | 18-OCT-15:20 | 96.66 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.450885E+10 | 0.121332E+10 | 1677.64 | 0.440781E+10 | 0.101040E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.182092E+10 | 0.490013E+09 | 597.04 | 0.177312E+10 | 47801999.12 | 0.00 | 0.52 | 0.00 | 2569.76 | 2569.76 | 483.48 | 759.40 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 4970531.76 | 1332519.78 | 6.33 | 4970531.76 | 0.00 | 0.00 | 0.08 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 462.13 | 27-FEB-15:30 | 462.13 | 27-FEB-15:30 | 0.00 | 27-FEB-13:20 | 123.44 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 27323071.40 | 7270146.51 | 17.33 | 27323071.40 | -0.0 | 0.00 | 0.14 | 07-APR-14:10 | 0.00 | 01-APR-00:10 | 790.00 | 07-APR-14:10 | 790.00 | 07-APR-14:10 | 0.00 | 25-APR-15:00 | 209.19 | 07-APR-14:10 | 0.00 | 01-APR-00:10 |
| May | 0.153474E+09 | 40236511.40 | 57.44 | 0.152735E+09 | 739116.59 | 0.00 | 0.45 | 19-MAY-08:63 | 0.00 | 01-MAY-00:10 | 2786.22 | 19-MAY-08:63 | 2786.22 | 19-MAY-08:63 | 49.70 | 30-MAY-08:65 | 691.36 | 19-MAY-08:63 | 0.00 | 01-MAY-00:10 |
| June | 0.114834E+10 | 0.296536E+09 | 182.66 | 0.111853E+10 | 29808110.92 | 0.00 | 1.00 | 21-JUN-08:62 | 0.00 | 01-JUN-00:10 | 7076.08 | 22-JUN-08:62 | 6948.32 | 26-JUN-07:02 | 770.38 | 13-JUN-08:62 | 1560.84 | 22-JUN-08:62 | 0.00 | 01-JUN-00:10 |
| July | 0.198228E+10 | 0.512747E+09 | 228.90 | 0.194713E+10 | 35158219.82 | 0.00 | 1.00 | 03-JUL-07:02 | 0.00 | 01-JUL-00:10 | 7396.86 | 19-JUL-07:02 | 7073.07 | 17-JUL-07:02 | 1398.45 | 19-JUL-08:62 | 1591.04 | 18-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.204878E+10 | 0.526327E+09 | 249.83 | 0.203647E+10 | 12300174.11 | 0.00 | 1.00 | 01-AUG-07:01 | 0.00 | 01-AUG-00:10 | 6992.29 | 09-AUG-07:02 | 6992.29 | 09-AUG-07:02 | 187.85 | 01-AUG-08:30 | 1569.99 | 09-AUG-08:62 | 0.00 | 01-AUG-00:10 |
| September | 0.111157E+10 | 0.282302E+09 | 188.52 | 0.107446E+10 | 37106295.54 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:10 | 7164.60 | 07-SEP-07:02 | 6999.47 | 05-SEP-07:02 | 1060.52 | 07-SEP-08:62 | 1566.95 | 07-SEP-07:02 | 0.00 | 01-SEP-00:10 |
| October | 0.434906E+09 | 0.112866E+09 | 114.14 | 0.434906E+09 | 0.00 | 0.00 | 0.96 | 19-OCT-08:62 | 0.00 | 01-OCT-00:10 | 6278.72 | 19-OCT-08:62 | 6278.72 | 19-OCT-08:62 | 0.00 | 25-OCT-10:20 | 1446.85 | 19-OCT-08:62 | 0.00 | 01-OCT-00:10 |
| November | 39493943.42 | 10542864.34 | 38.00 | 39493943.42 | 0.00 | 0.00 | 0.15 | 03-NOV-14:20 | 0.00 | 01-NOV-00:10 | 882.70 | 03-NOV-14:20 | 882.70 | 03-NOV-14:20 | 0.00 | 03-NOV-10:20 | 232.51 | 03-NOV-14:20 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.695113E+10 | 0.179016E+10 | 1083.16 | 0.683602E+10 | 0.115112E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.204878E+10 | 0.526327E+09 | 249.83 | 0.203647E+10 | 37106295.54 | 0.00 | 1.00 | 0.00 | 7396.86 | 7073.07 | 1398.45 | 1591.04 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 24093595.36 | 6579436.01 | 24.08 | 24093595.36 | 0.00 | 0.00 | 0.17 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 733.81 | 20-MAY-16:10 | 733.81 | 20-MAY-16:10 | 0.00 | 20-MAY-15:50 | 208.02 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.706580E+09 | 0.187681E+09 | 295.99 | 0.684171E+09 | 22409159.94 | 0.00 | 0.36 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 | 1569.73 | 29-JUN-15:10 | 1569.73 | 29-JUN-15:10 | 192.03 | 20-JUN-19:00 | 448.79 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.194161E+10 | 0.518482E+09 | 615.66 | 0.188950E+10 | 52108628.11 | 0.00 | 0.51 | 17-JUL-16:04 | 0.00 | 01-JUL-06:13 | 2181.82 | 17-JUL-16:04 | 2181.82 | 17-JUL-16:04 | 267.08 | 19-JUL-08:50 | 655.38 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.143809E+10 | 0.387202E+09 | 537.64 | 0.143356E+10 | 4532495.96 | 0.00 | 0.48 | 06-AUG-16:02 | 0.00 | 01-AUG-04:50 | 2057.58 | 06-AUG-17:08 | 2057.58 | 06-AUG-17:08 | 48.30 | 01-AUG-14:30 | 606.33 | 06-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.630948E+09 | 0.168141E+09 | 262.32 | 0.604190E+09 | 26757787.38 | 0.00 | 0.44 | 03-SEP-16:04 | 0.00 | 01-SEP-05:05 | 1909.43 | 03-SEP-16:04 | 1909.43 | 03-SEP-16:04 | 399.02 | 07-SEP-15:10 | 551.53 | 03-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 681059.87 | 184261.92 | 3.42 | 681059.87 | 0.00 | 0.00 | 0.03 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 134.13 | 18-OCT-16:05 | 134.13 | 18-OCT-16:05 | 0.00 | 18-OCT-15:50 | 36.03 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.474200E+10 | 0.126827E+10 | 1739.10 | 0.463620E+10 | 0.105808E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.194161E+10 | 0.518482E+09 | 615.66 | 0.188950E+10 | 52108628.11 | 0.00 | 0.51 | 0.00 | 2181.82 | 2181.82 | 399.02 | 655.38 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 20289190.73 | 5519535.76 | 26.21 | 20289190.73 | 0.00 | 0.00 | 0.15 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 594.95 | 20-MAY-16:10 | 594.95 | 20-MAY-16:10 | 0.00 | 20-MAY-15:20 | 169.06 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.531612E+09 | 0.141910E+09 | 297.06 | 0.513524E+09 | 18087626.54 | 0.00 | 0.32 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 1263.66 | 29-JUN-16:02 | 1263.66 | 29-JUN-16:02 | 165.00 | 20-JUN-19:00 | 356.17 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.152970E+10 | 0.410508E+09 | 637.52 | 0.148342E+10 | 46285731.84 | 0.00 | 0.46 | 17-JUL-18:00 | 0.00 | 01-JUL-06:13 | 1774.35 | 17-JUL-18:00 | 1774.35 | 17-JUL-18:00 | 206.78 | 19-JUL-08:50 | 529.77 | 17-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.113997E+10 | 0.308240E+09 | 561.08 | 0.113585E+10 | 4119687.63 | 0.00 | 0.43 | 06-AUG-17:04 | 0.00 | 01-AUG-22:50 | 1666.47 | 06-AUG-17:20 | 1666.47 | 06-AUG-17:20 | 40.06 | 22-AUG-14:10 | 490.19 | 06-AUG-17:04 | 0.00 | 01-AUG-00:10 |
| September | 0.546784E+09 | 0.145550E+09 | 264.33 | 0.518756E+09 | 28028266.43 | 0.00 | 0.40 | 03-SEP-16:02 | 0.00 | 01-SEP-05:05 | 1551.33 | 03-SEP-16:02 | 1551.33 | 03-SEP-16:02 | 379.95 | 07-SEP-15:10 | 450.98 | 03-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 192172.49 | 51861.18 | 1.17 | 192172.49 | 0.00 | 0.00 | 0.02 | 18-OCT-16:08 | 0.00 | 01-OCT-00:10 | 89.44 | 18-OCT-16:08 | 89.44 | 18-OCT-16:08 | 0.00 | 18-OCT-16:08 | 24.05 | 18-OCT-16:08 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.376855E+10 | 0.101178E+10 | 1787.37 | 0.367203E+10 | 96521312.44 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.152970E+10 | 0.410508E+09 | 637.52 | 0.148342E+10 | 46285731.84 | 0.00 | 0.46 | 0.00 | 1774.35 | 1774.35 | 379.95 | 529.77 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 19626680.53 | 5342950.25 | 25.42 | 19626680.53 | 0.00 | 0.00 | 0.15 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 593.94 | 20-MAY-16:10 | 593.94 | 20-MAY-16:10 | 0.00 | 20-MAY-17:03 | 168.77 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.537245E+09 | 0.143371E+09 | 299.74 | 0.518971E+09 | 18273796.38 | 0.00 | 0.32 | 29-JUN-16:04 | 0.00 | 01-JUN-00:10 | 1262.51 | 29-JUN-16:04 | 1262.51 | 29-JUN-16:04 | 165.28 | 20-JUN-19:00 | 355.82 | 29-JUN-16:04 | 0.00 | 01-JUN-00:10 |
| July | 0.153716E+10 | 0.412408E+09 | 638.29 | 0.149067E+10 | 46491976.98 | 0.00 | 0.46 | 17-JUL-18:00 | 0.00 | 01-JUL-06:13 | 1768.93 | 17-JUL-18:00 | 1768.93 | 17-JUL-18:00 | 207.65 | 19-JUL-08:50 | 528.17 | 17-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.114764E+10 | 0.310225E+09 | 563.81 | 0.114347E+10 | 4174256.22 | 0.00 | 0.43 | 06-AUG-17:04 | 0.00 | 01-AUG-22:50 | 1661.72 | 06-AUG-17:20 | 1661.72 | 06-AUG-17:20 | 40.55 | 22-AUG-14:10 | 488.80 | 06-AUG-17:04 | 0.00 | 01-AUG-00:10 |
| September | 0.547161E+09 | 0.145653E+09 | 265.17 | 0.519248E+09 | 27912393.44 | 0.00 | 0.40 | 03-SEP-16:04 | 0.00 | 01-SEP-05:05 | 1549.62 | 03-SEP-16:04 | 1549.62 | 03-SEP-16:04 | 378.05 | 07-SEP-15:10 | 450.45 | 03-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 150260.65 | 40520.92 | 1.00 | 150260.65 | 0.00 | 0.00 | 0.03 | 18-OCT-16:03 | 0.00 | 01-OCT-00:10 | 111.29 | 18-OCT-16:03 | 111.29 | 18-OCT-16:03 | 0.00 | 18-OCT-16:03 | 29.91 | 18-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.378898E+10 | 0.101704E+10 | 1793.43 | 0.369213E+10 | 96852423.02 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.153716E+10 | 0.412408E+09 | 638.29 | 0.149067E+10 | 46491976.98 | 0.00 | 0.46 | 0.00 | 1768.93 | 1768.93 | 378.05 | 528.17 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 24640.21 | 6659.07 | 0.33 | 24640.21 | -0.0 | 0.00 | 0.01 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 25.67 | 27-FEB-15:30 | 25.67 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 6.94 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 85931662.57 | 23037878.91 | 69.50 | 85879891.63 | 51770.94 | 0.00 | 0.22 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 | 995.57 | 20-MAY-16:05 | 995.57 | 20-MAY-16:05 | 5.43 | 20-MAY-11:50 | 279.62 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.793894E+09 | 0.210862E+09 | 379.95 | 0.769972E+09 | 23921715.47 | 0.00 | 0.36 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 | 1569.27 | 29-JUN-15:10 | 1569.27 | 29-JUN-15:10 | 188.05 | 20-JUN-20:00 | 449.16 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.205430E+10 | 0.548278E+09 | 673.44 | 0.199871E+10 | 55594143.92 | 0.00 | 0.50 | 17-JUL-16:10 | 0.00 | 04-JUL-02:00 | 2154.36 | 17-JUL-16:04 | 2154.36 | 17-JUL-16:04 | 232.92 | 18-JUL-21:05 | 648.66 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.191168E+10 | 0.509641E+09 | 647.85 | 0.190493E+10 | 6756281.68 | 0.00 | 0.50 | 10-AUG-15:10 | 0.00 | 02-AUG-01:40 | 2207.36 | 10-AUG-15:10 | 2207.36 | 10-AUG-15:10 | 58.82 | 22-AUG-13:50 | 633.97 | 06-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.123964E+10 | 0.325115E+09 | 433.05 | 0.120146E+10 | 38178133.60 | 0.00 | 0.54 | 02-SEP-15:10 | 0.00 | 08-SEP-08:55 | 2407.23 | 02-SEP-15:10 | 2407.23 | 02-SEP-15:10 | 484.06 | 07-SEP-15:10 | 690.50 | 02-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.314866E+09 | 82911676.47 | 209.55 | 0.314866E+09 | 0.00 | 0.00 | 0.37 | 18-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1694.22 | 18-OCT-15:10 | 1694.22 | 18-OCT-15:10 | 0.00 | 18-OCT-15:50 | 438.16 | 18-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 3754087.46 | 1004160.80 | 8.76 | 3754087.46 | 0.00 | 0.00 | 0.06 | 03-NOV-15:10 | 0.00 | 01-NOV-00:10 | 251.60 | 03-NOV-15:10 | 251.60 | 03-NOV-15:10 | 0.00 | 03-NOV-16:04 | 67.07 | 03-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.640410E+10 | 0.170086E+10 | 2422.45 | 0.627959E+10 | 0.124502E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.205430E+10 | 0.548278E+09 | 673.44 | 0.199871E+10 | 55594143.92 | 0.00 | 0.54 | 0.00 | 2407.23 | 2407.23 | 484.06 | 690.50 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 96400894.33 | 25800747.47 | 74.08 | 96334215.76 | 66678.57 | 0.00 | 0.23 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 1055.72 | 20-MAY-16:10 | 1055.72 | 20-MAY-16:10 | 7.00 | 20-MAY-22:00 | 295.99 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.893626E+09 | 0.236714E+09 | 410.91 | 0.867439E+09 | 26187409.77 | 0.00 | 0.37 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 | 1634.69 | 29-JUN-15:10 | 1634.69 | 29-JUN-15:10 | 196.75 | 20-JUN-20:00 | 467.00 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.228062E+10 | 0.606320E+09 | 689.80 | 0.221935E+10 | 61269867.06 | 0.00 | 0.52 | 17-JUL-16:10 | 0.00 | 04-JUL-23:10 | 2259.17 | 17-JUL-16:04 | 2259.17 | 17-JUL-16:04 | 252.05 | 18-JUL-21:05 | 678.09 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.211485E+10 | 0.561881E+09 | 670.01 | 0.210708E+10 | 7767834.01 | 0.00 | 0.52 | 06-AUG-16:03 | 0.00 | 02-AUG-04:00 | 2296.51 | 06-AUG-16:03 | 2296.51 | 06-AUG-16:03 | 60.20 | 22-AUG-13:50 | 674.05 | 06-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.138224E+10 | 0.361433E+09 | 450.96 | 0.134090E+10 | 41342007.19 | 0.00 | 0.56 | 02-SEP-15:10 | 0.00 | 08-SEP-08:55 | 2538.49 | 02-SEP-15:10 | 2538.49 | 02-SEP-15:10 | 492.56 | 07-SEP-15:10 | 725.36 | 02-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.344086E+09 | 90569486.70 | 223.71 | 0.344086E+09 | -0.0 | 0.00 | 0.38 | 18-OCT-15:10 | 0.00 | 01-OCT-00:20 | 1736.57 | 18-OCT-15:10 | 1736.57 | 18-OCT-15:10 | 0.00 | 15-OCT-14:40 | 448.66 | 18-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 6075994.30 | 1623428.88 | 11.74 | 6075994.30 | 0.00 | 0.00 | 0.10 | 04-NOV-17:10 | 0.00 | 01-NOV-00:10 | 444.70 | 04-NOV-17:10 | 444.70 | 04-NOV-17:10 | 0.00 | 03-NOV-15:00 | 118.07 | 04-NOV-17:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.711789E+10 | 0.188434E+10 | 2531.23 | 0.698126E+10 | 0.136634E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.228062E+10 | 0.606320E+09 | 689.80 | 0.221935E+10 | 61269867.06 | 0.00 | 0.56 | 0.00 | 2538.49 | 2538.49 | 492.56 | 725.36 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 93045864.31 | 24751188.80 | 22.75 | 93045864.31 | 0.00 | 0.00 | 0.17 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 2355.71 | 27-FEB-15:30 | 2355.71 | 27-FEB-15:30 | 0.00 | 26-FEB-16:10 | 620.70 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 |
| March | 21686752.83 | 5803593.78 | 11.96 | 21686752.83 | 0.00 | 0.00 | 0.11 | 01-MAR-16:20 | 0.00 | 01-MAR-00:10 | 1507.82 | 01-MAR-16:20 | 1507.82 | 01-MAR-16:20 | 0.00 | 01-MAR-15:20 | 400.71 | 01-MAR-16:20 | 0.00 | 01-MAR-00:10 |
| April | 0.390112E+09 | 0.103141E+09 | 103.08 | 0.390112E+09 | -0.0 | 0.00 | 0.26 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 3675.01 | 06-APR-16:10 | 3675.01 | 06-APR-16:10 | 0.00 | 24-APR-18:50 | 950.49 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.139901E+10 | 0.367152E+09 | 249.67 | 0.139742E+10 | 1589262.57 | 0.00 | 0.38 | 19-MAY-16:10 | 0.00 | 01-MAY-00:10 | 5492.28 | 19-MAY-16:10 | 5492.28 | 19-MAY-16:10 | 54.75 | 20-MAY-22:40 | 1455.31 | 19-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.396294E+10 | 0.104207E+10 | 539.33 | 0.387093E+10 | 92018961.81 | 0.00 | 0.43 | 28-JUN-17:40 | 0.00 | 01-JUN-21:13 | 5912.64 | 28-JUN-17:40 | 5912.64 | 28-JUN-17:40 | 595.15 | 20-JUN-19:00 | 1631.26 | 28-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.653764E+10 | 0.174375E+10 | 694.05 | 0.639226E+10 | 0.145384E+09 | 0.00 | 0.54 | 17-JUL-16:10 | 0.00 | 04-JUL-01:30 | 7206.65 | 17-JUL-16:03 | 7206.65 | 17-JUL-16:03 | 626.72 | 18-JUL-21:05 | 2156.38 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.570102E+10 | 0.152115E+10 | 651.28 | 0.568422E+10 | 16798886.60 | 0.00 | 0.52 | 06-AUG-16:03 | 0.00 | 01-AUG-23:10 | 7004.55 | 06-AUG-16:03 | 7004.55 | 06-AUG-16:03 | 177.15 | 01-AUG-14:30 | 2057.16 | 06-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.335778E+10 | 0.884807E+09 | 427.63 | 0.327155E+10 | 86227023.35 | 0.00 | 0.53 | 02-SEP-15:20 | 0.00 | 08-SEP-08:55 | 7396.84 | 02-SEP-15:20 | 7396.84 | 02-SEP-15:20 | 1359.20 | 07-SEP-15:00 | 2120.45 | 02-SEP-15:20 | 0.00 | 01-SEP-00:10 |
| October | 0.877191E+09 | 0.230626E+09 | 174.61 | 0.877191E+09 | -0.0 | 0.00 | 0.38 | 18-OCT-15:20 | 0.00 | 01-OCT-00:10 | 5390.59 | 18-OCT-15:20 | 5390.59 | 18-OCT-15:20 | 0.00 | 16-OCT-14:10 | 1390.26 | 18-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 26183019.33 | 6992928.69 | 14.86 | 26183019.33 | -0.0 | 0.00 | 0.10 | 03-NOV-15:30 | 0.00 | 01-NOV-00:10 | 1326.74 | 03-NOV-15:30 | 1326.74 | 03-NOV-15:30 | 0.00 | 03-NOV-15:50 | 351.61 | 03-NOV-15:30 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.223666E+11 | 0.593024E+10 | 2889.22 | 0.220246E+11 | 0.342018E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.653764E+10 | 0.174375E+10 | 694.05 | 0.639226E+10 | 0.145384E+09 | 0.00 | 0.54 | 0.00 | 7396.84 | 7396.84 | 1359.20 | 2156.38 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 20092561.50 | 5384999.72 | 13.97 | 20092561.50 | -0.0 | 0.00 | 0.08 | 25-APR-18:40 | 0.00 | 01-APR-00:10 | 1071.64 | 25-APR-18:40 | 1071.64 | 25-APR-18:40 | 0.00 | 25-APR-16:05 | 285.59 | 25-APR-18:40 | 0.00 | 01-APR-00:10 |
| May | 0.879258E+09 | 0.231703E+09 | 185.89 | 0.878320E+09 | 938079.00 | 0.00 | 0.33 | 19-MAY-17:40 | 0.00 | 01-MAY-00:10 | 4516.97 | 19-MAY-17:40 | 4516.97 | 19-MAY-17:40 | 44.02 | 20-MAY-22:40 | 1175.07 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.327791E+10 | 0.864150E+09 | 511.28 | 0.319446E+10 | 83452056.84 | 0.00 | 0.43 | 28-JUN-18:00 | 0.00 | 01-JUN-21:03 | 5621.28 | 28-JUN-18:00 | 5621.28 | 28-JUN-18:00 | 575.81 | 20-JUN-19:00 | 1544.55 | 28-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.543591E+10 | 0.145563E+10 | 684.15 | 0.530368E+10 | 0.132227E+09 | 0.00 | 0.51 | 17-JUL-17:50 | 0.00 | 04-JUL-01:00 | 6495.28 | 17-JUL-17:50 | 6495.28 | 17-JUL-17:50 | 579.43 | 18-JUL-21:05 | 1924.07 | 17-JUL-17:50 | 0.00 | 01-JUL-00:10 |
| August | 0.405623E+10 | 0.109318E+10 | 604.02 | 0.404316E+10 | 13072901.22 | 0.00 | 0.47 | 06-AUG-16:30 | 0.00 | 01-AUG-22:40 | 5896.61 | 06-AUG-16:30 | 5896.61 | 06-AUG-16:30 | 141.83 | 01-AUG-14:30 | 1741.73 | 06-AUG-16:30 | 0.00 | 01-AUG-00:10 |
| September | 0.179164E+10 | 0.478369E+09 | 305.47 | 0.172049E+10 | 71149483.47 | 0.00 | 0.41 | 02-SEP-17:00 | 0.00 | 01-SEP-05:05 | 5280.20 | 02-SEP-17:00 | 5280.20 | 02-SEP-17:00 | 1191.29 | 07-SEP-15:10 | 1547.88 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 27701799.88 | 7428535.15 | 14.67 | 27701799.88 | 0.00 | 0.00 | 0.13 | 18-OCT-16:08 | 0.00 | 01-OCT-00:10 | 1671.27 | 18-OCT-16:08 | 1671.27 | 18-OCT-16:08 | 0.00 | 16-OCT-16:17 | 442.31 | 18-OCT-16:08 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.154887E+11 | 0.413585E+10 | 2319.45 | 0.151879E+11 | 0.300839E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.543591E+10 | 0.145563E+10 | 684.15 | 0.530368E+10 | 0.132227E+09 | 0.00 | 0.51 | 0.00 | 6495.28 | 6495.28 | 1191.29 | 1924.07 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 91254927.92 | 24287185.75 | 26.71 | 91254927.92 | -0.0 | 0.00 | 0.16 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 1926.24 | 27-FEB-15:30 | 1926.24 | 27-FEB-15:30 | 0.00 | 28-FEB-14:10 | 508.22 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 |
| March | 9307647.85 | 2495541.95 | 5.50 | 9307647.85 | -0.0 | 0.00 | 0.07 | 01-MAR-16:10 | 0.00 | 01-MAR-00:10 | 773.83 | 01-MAR-16:10 | 773.83 | 01-MAR-16:10 | 0.00 | 01-MAR-13:50 | 207.04 | 01-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.424652E+09 | 0.112265E+09 | 124.85 | 0.424652E+09 | 0.00 | 0.00 | 0.24 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 2934.92 | 06-APR-16:10 | 2934.92 | 06-APR-16:10 | 0.00 | 06-APR-13:40 | 761.28 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.131333E+10 | 0.344192E+09 | 256.59 | 0.131173E+10 | 1592137.19 | 0.00 | 0.38 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 | 4737.54 | 19-MAY-15:10 | 4737.54 | 19-MAY-15:10 | 65.35 | 28-MAY-10:30 | 1266.69 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.417291E+10 | 0.109067E+10 | 563.42 | 0.407435E+10 | 98556435.47 | 0.00 | 0.46 | 29-JUN-14:30 | 0.00 | 01-JUN-21:03 | 5444.26 | 29-JUN-14:30 | 5444.26 | 29-JUN-14:30 | 585.52 | 20-JUN-20:00 | 1531.88 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.681593E+10 | 0.180223E+10 | 699.65 | 0.665936E+10 | 0.156576E+09 | 0.00 | 0.54 | 25-JUL-13:00 | 0.00 | 04-JUL-02:70 | 6416.67 | 25-JUL-13:00 | 6416.67 | 25-JUL-13:00 | 713.31 | 19-JUL-08:50 | 1861.71 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.594623E+10 | 0.157457E+10 | 664.45 | 0.592793E+10 | 18301089.46 | 0.00 | 0.55 | 10-AUG-15:00 | 0.00 | 02-AUG-01:20 | 6494.08 | 10-AUG-13:00 | 6494.08 | 10-AUG-13:00 | 167.22 | 01-AUG-14:30 | 1826.99 | 10-AUG-15:00 | 0.00 | 01-AUG-00:10 |
| September | 0.335941E+10 | 0.881316E+09 | 439.32 | 0.327764E+10 | 81768011.02 | 0.00 | 0.57 | 02-SEP-14:10 | 0.00 | 08-SEP-08:55 | 6914.54 | 02-SEP-14:00 | 6914.54 | 02-SEP-14:00 | 1181.06 | 07-SEP-15:10 | 1959.16 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.860646E+09 | 0.226073E+09 | 188.01 | 0.860646E+09 | 0.00 | 0.00 | 0.39 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 | 4790.22 | 18-OCT-14:10 | 4790.22 | 18-OCT-14:10 | 0.00 | 15-OCT-13:50 | 1236.76 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 20471679.34 | 5463114.13 | 11.33 | 20471679.34 | -0.0 | 0.00 | 0.09 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 | 1031.19 | 03-NOV-14:10 | 1031.19 | 03-NOV-14:10 | 0.00 | 03-NOV-15:00 | 273.54 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.230141E+11 | 0.606356E+10 | 2979.83 | 0.226573E+11 | 0.356794E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.681593E+10 | 0.180223E+10 | 699.65 | 0.665936E+10 | 0.156576E+09 | 0.00 | 0.57 | 0.00 | 6914.54 | 6914.54 | 1181.06 | 1959.16 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 7161290.39 | 1927381.06 | 11.46 | 7161290.39 | 0.00 | 0.00 | 0.05 | 25-APR-18:50 | 0.00 | 01-APR-00:10 | 551.93 | 25-APR-18:50 | 551.93 | 25-APR-18:50 | 0.00 | 07-APR-17:30 | 147.79 | 25-APR-18:50 | 0.00 | 01-APR-00:10 |
| May | 0.781577E+09 | 0.205965E+09 | 180.27 | 0.780665E+09 | 912287.05 | 0.00 | 0.32 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 | 3660.61 | 20-MAY-16:05 | 3660.61 | 20-MAY-16:05 | 41.66 | 20-MAY-22:40 | 1012.99 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.347821E+10 | 0.911784E+09 | 541.50 | 0.338827E+10 | 89941440.82 | 0.00 | 0.41 | 29-JUN-15:10 | 0.00 | 01-JUN-05:00 | 4512.52 | 29-JUN-15:10 | 4512.52 | 29-JUN-15:10 | 565.60 | 20-JUN-19:00 | 1280.79 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.571404E+10 | 0.151707E+10 | 690.10 | 0.557054E+10 | 0.143496E+09 | 0.00 | 0.49 | 17-JUL-16:04 | 0.00 | 04-JUL-01:50 | 5271.42 | 17-JUL-16:03 | 5271.42 | 17-JUL-16:03 | 700.01 | 19-JUL-08:40 | 1589.07 | 17-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.428595E+10 | 0.114725E+10 | 624.27 | 0.427124E+10 | 14708793.48 | 0.00 | 0.47 | 06-AUG-16:03 | 0.00 | 01-AUG-23:00 | 5004.65 | 06-AUG-16:03 | 5004.65 | 06-AUG-16:03 | 135.82 | 22-AUG-14:10 | 1483.56 | 06-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.174534E+10 | 0.464801E+09 | 317.35 | 0.168020E+10 | 65147500.34 | 0.00 | 0.41 | 03-SEP-16:10 | 0.00 | 01-SEP-05:05 | 4446.55 | 03-SEP-16:10 | 4446.55 | 03-SEP-16:10 | 950.13 | 07-SEP-15:10 | 1298.19 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 22838314.67 | 6138563.23 | 14.33 | 22838314.67 | -0.0 | 0.00 | 0.08 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 914.25 | 18-OCT-16:05 | 914.25 | 18-OCT-16:05 | 0.00 | 18-OCT-13:40 | 243.66 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.160351E+11 | 0.425494E+10 | 2379.28 | 0.157209E+11 | 0.314206E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.571404E+10 | 0.151707E+10 | 690.10 | 0.557054E+10 | 0.143496E+09 | 0.00 | 0.49 | 0.00 | 5271.42 | 5271.42 | 950.13 | 1589.07 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 688670.73 | 185849.17 | 1.67 | 688670.73 | 0.00 | 0.00 | 0.01 | 07-APR-18:00 | 0.00 | 01-APR-00:10 | 139.10 | 07-APR-18:00 | 139.10 | 07-APR-18:00 | 0.00 | 07-APR-17:20 | 37.50 | 07-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.631759E+09 | 0.166790E+09 | 189.40 | 0.630375E+09 | 1384450.10 | 0.00 | 0.30 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 | 3004.02 | 20-MAY-16:05 | 3004.02 | 20-MAY-16:05 | 43.71 | 20-MAY-23:00 | 834.27 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.257995E+10 | 0.680213E+09 | 559.38 | 0.250296E+10 | 76981848.04 | 0.00 | 0.35 | 29-JUN-16:04 | 0.00 | 01-JUN-22:10 | 3534.40 | 20-JUN-17:30 | 3408.80 | 29-JUN-16:04 | 492.18 | 20-JUN-20:00 | 960.34 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.426033E+10 | 0.113890E+10 | 706.90 | 0.413768E+10 | 0.122641E+09 | 0.00 | 0.43 | 17-JUL-18:00 | 0.00 | 04-JUL-03:00 | 4091.91 | 17-JUL-18:00 | 4091.91 | 17-JUL-18:00 | 514.35 | 18-JUL-21:05 | 1228.90 | 17-JUL-16:09 | 0.00 | 01-JUL-00:10 |
| August | 0.323691E+10 | 0.871136E+09 | 655.86 | 0.322349E+10 | 13419993.90 | 0.00 | 0.41 | 06-AUG-16:17 | 0.00 | 02-AUG-01:40 | 3854.18 | 06-AUG-17:17 | 3854.18 | 06-AUG-17:17 | 115.38 | 22-AUG-14:10 | 1147.52 | 06-AUG-16:17 | 0.00 | 01-AUG-00:10 |
| September | 0.145800E+10 | 0.388256E+09 | 324.38 | 0.139277E+10 | 65229037.56 | 0.00 | 0.36 | 03-SEP-16:06 | 0.00 | 01-SEP-05:40 | 3518.62 | 03-SEP-16:06 | 3518.62 | 03-SEP-16:06 | 876.18 | 07-SEP-15:10 | 1028.53 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 21707955.73 | 5829825.68 | 15.67 | 21707955.73 | -0.0 | 0.00 | 0.09 | 18-OCT-16:10 | 0.00 | 01-OCT-00:10 | 881.56 | 18-OCT-16:10 | 881.56 | 18-OCT-16:10 | 0.00 | 18-OCT-13:40 | 234.71 | 18-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.121893E+11 | 0.325131E+10 | 2453.25 | 0.119097E+11 | 0.279656E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.426033E+10 | 0.113890E+10 | 706.90 | 0.413768E+10 | 0.122641E+09 | 0.00 | 0.43 | 0.00 | 4091.91 | 4091.91 | 876.18 | 1228.90 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 819784.56 | 221199.63 | 2.17 | 819784.56 | 0.00 | 0.00 | 0.02 | 07-APR-18:00 | 0.00 | 01-APR-00:10 | 152.90 | 07-APR-18:00 | 152.90 | 07-APR-18:00 | 0.00 | 07-APR-17:50 | 41.21 | 07-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.631381E+09 | 0.166696E+09 | 189.66 | 0.630003E+09 | 1378072.46 | 0.00 | 0.30 | 20-MAY-16:08 | 0.00 | 01-MAY-00:10 | 3001.51 | 20-MAY-16:08 | 3001.51 | 20-MAY-16:08 | 43.63 | 20-MAY-23:00 | 833.52 | 20-MAY-16:08 | 0.00 | 01-MAY-00:10 |
| June | 0.259311E+10 | 0.683579E+09 | 561.28 | 0.251586E+10 | 77244554.58 | 0.00 | 0.35 | 29-JUN-16:08 | 0.00 | 01-JUN-22:10 | 3527.06 | 20-JUN-17:30 | 3406.01 | 29-JUN-16:08 | 492.04 | 20-JUN-20:00 | 961.61 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.427201E+10 | 0.114182E+10 | 706.92 | 0.414908E+10 | 0.122937E+09 | 0.00 | 0.43 | 17-JUL-18:00 | 0.00 | 04-JUL-23:30 | 4072.64 | 17-JUL-18:00 | 4072.64 | 17-JUL-18:00 | 513.75 | 18-JUL-21:05 | 1226.96 | 17-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.325037E+10 | 0.874592E+09 | 656.71 | 0.323687E+10 | 13502146.19 | 0.00 | 0.41 | 06-AUG-16:03 | 0.00 | 02-AUG-01:50 | 3843.66 | 06-AUG-17:20 | 3843.66 | 06-AUG-17:20 | 115.70 | 22-AUG-14:10 | 1146.01 | 06-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.146084E+10 | 0.389004E+09 | 325.68 | 0.139585E+10 | 64995162.21 | 0.00 | 0.36 | 03-SEP-16:02 | 0.00 | 01-SEP-05:40 | 3510.72 | 03-SEP-16:02 | 3510.72 | 03-SEP-16:02 | 871.76 | 07-SEP-15:10 | 1026.19 | 03-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 21677147.23 | 5821710.09 | 15.50 | 21677147.23 | 0.00 | 0.00 | 0.09 | 18-OCT-16:03 | 0.00 | 01-OCT-00:10 | 868.08 | 18-OCT-16:05 | 868.08 | 18-OCT-16:05 | 0.00 | 18-OCT-14:00 | 231.16 | 18-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.122302E+11 | 0.326173E+10 | 2457.91 | 0.119501E+11 | 0.280057E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.427201E+10 | 0.114182E+10 | 706.92 | 0.414908E+10 | 0.122937E+09 | 0.00 | 0.43 | 0.00 | 4072.64 | 4072.64 | 871.76 | 1226.96 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.137073E+09 | 36297681.64 | 34.17 | 0.137073E+09 | -0.0 | 0.00 | 0.21 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 2224.79 | 27-FEB-15:30 | 2224.79 | 27-FEB-15:30 | 0.00 | 25-FEB-15:40 | 583.07 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 |
| March | 33722789.66 | 8991058.87 | 16.16 | 33722789.66 | -0.0 | 0.00 | 0.14 | 01-MAR-15:20 | 0.00 | 01-MAR-00:10 | 1445.78 | 01-MAR-15:20 | 1445.78 | 01-MAR-15:20 | 0.00 | 01-MAR-16:20 | 382.82 | 01-MAR-15:20 | 0.00 | 01-MAR-00:10 |
| April | 0.371861E+09 | 98544406.94 | 136.73 | 0.371861E+09 | 0.00 | 0.00 | 0.24 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 2677.48 | 06-APR-16:10 | 2677.48 | 06-APR-16:10 | 0.00 | 06-APR-16:20 | 694.35 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.115421E+10 | 0.303194E+09 | 269.10 | 0.115198E+10 | 2225197.11 | 0.00 | 0.35 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 | 3888.37 | 19-MAY-15:10 | 3888.37 | 19-MAY-15:10 | 55.44 | 20-MAY-23:00 | 1045.11 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.327893E+10 | 0.861736E+09 | 584.28 | 0.319205E+10 | 86876268.74 | 0.00 | 0.40 | 29-JUN-14:30 | 0.00 | 01-JUN-22:20 | 4218.76 | 29-JUN-14:30 | 4218.76 | 29-JUN-14:30 | 516.71 | 20-JUN-20:00 | 1198.94 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.536894E+10 | 0.142886E+10 | 716.48 | 0.523153E+10 | 0.137407E+09 | 0.00 | 0.48 | 17-JUL-16:04 | 0.00 | 05-JUL-00:10 | 5016.63 | 25-JUL-15:10 | 5016.63 | 25-JUL-15:10 | 565.35 | 18-JUL-21:05 | 1503.21 | 17-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.491312E+10 | 0.130674E+10 | 700.34 | 0.489516E+10 | 17960705.81 | 0.00 | 0.49 | 10-AUG-15:10 | 0.00 | 02-AUG-04:00 | 5206.95 | 10-AUG-15:10 | 5206.95 | 10-AUG-15:10 | 145.14 | 22-AUG-13:50 | 1494.32 | 10-AUG-15:00 | 0.00 | 01-AUG-00:10 |
| September | 0.312617E+10 | 0.820429E+09 | 469.72 | 0.304400E+10 | 82176604.21 | 0.00 | 0.53 | 02-SEP-15:10 | 0.00 | 08-SEP-08:55 | 5720.86 | 02-SEP-14:10 | 5720.86 | 02-SEP-14:10 | 1112.22 | 07-SEP-15:10 | 1638.14 | 02-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.111675E+10 | 0.292956E+09 | 265.97 | 0.111675E+10 | -0.0 | 0.00 | 0.42 | 18-OCT-14:10 | 0.00 | 01-OCT-00:40 | 4634.14 | 18-OCT-14:10 | 4634.14 | 18-OCT-14:10 | 0.00 | 15-OCT-13:20 | 1191.81 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.100911E+09 | 26841842.39 | 49.95 | 0.100911E+09 | 0.00 | 0.00 | 0.16 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 | 1743.71 | 03-NOV-14:10 | 1743.71 | 03-NOV-14:10 | 0.00 | 03-NOV-16:04 | 457.41 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.196017E+11 | 0.518460E+10 | 3242.90 | 0.192750E+11 | 0.326646E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.536894E+10 | 0.142886E+10 | 716.48 | 0.523153E+10 | 0.137407E+09 | 0.00 | 0.53 | 0.00 | 5720.86 | 5720.86 | 1112.22 | 1638.14 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.139000E+09 | 36798928.23 | 34.17 | 0.139000E+09 | 0.00 | 0.00 | 0.21 | 26-FEB-13:50 | 0.00 | 01-FEB-00:10 | 2243.67 | 26-FEB-13:50 | 2243.67 | 26-FEB-13:50 | 0.00 | 28-FEB-14:20 | 587.81 | 26-FEB-13:50 | 0.00 | 01-FEB-00:10 |
| March | 34354834.70 | 9159292.16 | 16.84 | 34354834.70 | 0.00 | 0.00 | 0.14 | 01-MAR-15:20 | 0.00 | 01-MAR-00:10 | 1458.27 | 01-MAR-15:20 | 1458.27 | 01-MAR-15:20 | 0.00 | 01-MAR-13:40 | 386.04 | 01-MAR-15:20 | 0.00 | 01-MAR-00:10 |
| April | 0.382097E+09 | 0.101235E+09 | 138.60 | 0.382097E+09 | -0.0 | 0.00 | 0.25 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 2699.86 | 06-APR-16:10 | 2699.86 | 06-APR-16:10 | 0.00 | 25-APR-14:40 | 699.87 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.115536E+10 | 0.303482E+09 | 269.36 | 0.115314E+10 | 2218655.88 | 0.00 | 0.35 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 | 3892.35 | 19-MAY-15:10 | 3892.35 | 19-MAY-15:10 | 55.33 | 20-MAY-23:00 | 1045.98 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.329139E+10 | 0.864853E+09 | 584.66 | 0.320430E+10 | 87092645.32 | 0.00 | 0.40 | 29-JUN-14:30 | 0.00 | 01-JUN-22:20 | 4227.64 | 29-JUN-14:30 | 4227.64 | 29-JUN-14:30 | 516.66 | 20-JUN-20:00 | 1201.11 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.538047E+10 | 0.143163E+10 | 715.98 | 0.524279E+10 | 0.137679E+09 | 0.00 | 0.48 | 17-JUL-16:04 | 0.00 | 04-JUL-24:00 | 5022.14 | 25-JUL-15:10 | 5022.14 | 25-JUL-15:10 | 564.72 | 18-JUL-21:05 | 1501.50 | 17-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.492554E+10 | 0.130977E+10 | 700.29 | 0.490752E+10 | 18014820.96 | 0.00 | 0.49 | 10-AUG-15:10 | 0.00 | 03-AUG-04:30 | 5211.46 | 10-AUG-15:10 | 5211.46 | 10-AUG-15:10 | 145.20 | 22-AUG-13:50 | 1495.69 | 10-AUG-15:00 | 0.00 | 01-AUG-00:10 |
| September | 0.313298E+10 | 0.822119E+09 | 470.61 | 0.305098E+10 | 82003170.59 | 0.00 | 0.53 | 02-SEP-15:10 | 0.00 | 08-SEP-08:55 | 5733.16 | 02-SEP-14:10 | 5733.16 | 02-SEP-14:10 | 1108.98 | 07-SEP-14:50 | 1638.25 | 02-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.112302E+10 | 0.294575E+09 | 267.03 | 0.112302E+10 | 0.00 | 0.00 | 0.42 | 18-OCT-14:10 | 0.00 | 01-OCT-00:40 | 4641.68 | 18-OCT-14:10 | 4641.68 | 18-OCT-14:10 | 0.00 | 18-OCT-13:10 | 1193.42 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.102437E+09 | 27243016.46 | 50.27 | 0.102437E+09 | -0.0 | 0.00 | 0.16 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 | 1766.82 | 03-NOV-14:10 | 1766.82 | 03-NOV-14:10 | 0.00 | 03-NOV-15:20 | 463.29 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.196666E+11 | 0.520087E+10 | 3247.80 | 0.193396E+11 | 0.327008E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.538047E+10 | 0.143163E+10 | 715.98 | 0.524279E+10 | 0.137679E+09 | 0.00 | 0.53 | 0.00 | 5733.16 | 5733.16 | 1108.98 | 1638.25 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 90581637.23 | 23944136.26 | 30.17 | 90581637.23 | -0.0 | 0.00 | 0.24 | 26-FEB-17:00 | 0.00 | 01-FEB-00:10 | 1876.24 | 26-FEB-17:00 | 1876.24 | 26-FEB-17:00 | 0.00 | 25-FEB-14:20 | 488.93 | 26-FEB-17:00 | 0.00 | 01-FEB-00:10 |
| March | 83466315.83 | 22205602.27 | 39.17 | 83466315.83 | 0.00 | 0.00 | 0.16 | 22-MAR-16:10 | 0.00 | 01-MAR-00:10 | 1231.00 | 22-MAR-16:10 | 1231.00 | 22-MAR-16:10 | 0.00 | 22-MAR-17:03 | 324.86 | 22-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.359786E+09 | 94458210.76 | 114.42 | 0.359786E+09 | -0.0 | 0.00 | 0.35 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 2756.11 | 06-APR-16:10 | 2756.11 | 06-APR-16:10 | 0.00 | 06-APR-14:50 | 703.27 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.832357E+09 | 0.217757E+09 | 214.44 | 0.832074E+09 | 282052.51 | 0.00 | 0.45 | 19-MAY-16:10 | 0.00 | 01-MAY-00:10 | 3649.16 | 19-MAY-16:07 | 3649.16 | 19-MAY-16:07 | 43.07 | 02-MAY-13:30 | 956.39 | 19-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.204611E+10 | 0.536510E+09 | 390.50 | 0.200464E+10 | 41473750.64 | 0.00 | 0.49 | 28-JUN-17:15 | 0.00 | 01-JUN-01:20 | 3831.44 | 30-JUN-16:06 | 3831.44 | 30-JUN-16:06 | 327.12 | 20-JUN-18:50 | 1059.09 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.343737E+10 | 0.917506E+09 | 542.99 | 0.337647E+10 | 60902442.73 | 0.00 | 0.64 | 17-JUL-16:10 | 0.00 | 01-JUL-06:13 | 4883.62 | 17-JUL-16:04 | 4883.62 | 17-JUL-16:04 | 340.29 | 19-JUL-12:20 | 1436.08 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.292052E+10 | 0.779349E+09 | 490.47 | 0.291425E+10 | 6269998.55 | 0.00 | 0.61 | 06-AUG-16:02 | 0.00 | 01-AUG-03:10 | 4633.27 | 06-AUG-16:02 | 4633.27 | 06-AUG-16:02 | 109.01 | 01-AUG-14:30 | 1341.06 | 06-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.166436E+10 | 0.438402E+09 | 317.50 | 0.162777E+10 | 36591021.42 | 0.00 | 0.62 | 02-SEP-15:20 | 0.00 | 01-SEP-02:40 | 4821.00 | 02-SEP-15:20 | 4821.00 | 02-SEP-15:20 | 832.52 | 07-SEP-15:00 | 1363.45 | 02-SEP-15:20 | 0.00 | 01-SEP-00:10 |
| October | 0.424039E+09 | 0.111079E+09 | 129.58 | 0.424039E+09 | 0.00 | 0.00 | 0.41 | 18-OCT-15:20 | 0.00 | 01-OCT-00:10 | 3268.10 | 18-OCT-15:20 | 3268.10 | 18-OCT-15:20 | 0.00 | 15-OCT-15:00 | 838.12 | 18-OCT-15:20 | 0.00 | 01-OCT-00:10 |
| November | 37307462.88 | 9911132.83 | 23.88 | 37307462.88 | -0.0 | 0.00 | 0.18 | 03-NOV-15:20 | 0.00 | 01-NOV-00:10 | 1376.94 | 03-NOV-15:20 | 1376.94 | 03-NOV-15:20 | 0.00 | 03-NOV-15:30 | 360.41 | 03-NOV-15:20 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.118959E+11 | 0.315112E+10 | 2293.11 | 0.117504E+11 | 0.145519E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.343737E+10 | 0.917506E+09 | 542.99 | 0.337647E+10 | 60902442.73 | 0.00 | 0.64 | 0.00 | 4883.62 | 4883.62 | 832.52 | 1436.08 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 65712987.68 | 17453086.50 | 35.28 | 65712987.68 | -0.0 | 0.00 | 0.16 | 06-APR-17:20 | 0.00 | 01-APR-00:10 | 1184.73 | 06-APR-17:20 | 1184.73 | 06-APR-17:20 | 0.00 | 25-APR-17:00 | 311.01 | 06-APR-17:20 | 0.00 | 01-APR-00:10 |
| May | 0.534220E+09 | 0.140441E+09 | 161.83 | 0.534095E+09 | 124998.66 | 0.00 | 0.39 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 | 3059.98 | 19-MAY-17:30 | 3059.98 | 19-MAY-17:30 | 14.90 | 20-MAY-22:00 | 789.76 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.168255E+10 | 0.443132E+09 | 375.82 | 0.164401E+10 | 38544926.95 | 0.00 | 0.48 | 28-JUN-18:00 | 0.00 | 01-JUN-00:50 | 3632.96 | 28-JUN-18:00 | 3632.96 | 28-JUN-18:00 | 322.90 | 20-JUN-18:10 | 989.84 | 28-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.284893E+10 | 0.765402E+09 | 534.73 | 0.279299E+10 | 55934316.84 | 0.00 | 0.59 | 17-JUL-17:30 | 0.00 | 01-JUL-06:13 | 4335.32 | 17-JUL-17:30 | 4335.32 | 17-JUL-17:30 | 307.68 | 19-JUL-12:20 | 1267.77 | 17-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.206758E+10 | 0.559357E+09 | 455.31 | 0.206265E+10 | 4933365.12 | 0.00 | 0.54 | 06-AUG-16:30 | 0.00 | 01-AUG-03:00 | 3942.05 | 06-AUG-16:30 | 3942.05 | 06-AUG-16:30 | 85.43 | 22-AUG-14:10 | 1150.51 | 06-AUG-16:30 | 0.00 | 01-AUG-00:10 |
| September | 0.880400E+09 | 0.236166E+09 | 229.78 | 0.850172E+09 | 30227816.04 | 0.00 | 0.47 | 02-SEP-17:00 | 0.00 | 01-SEP-01:40 | 3463.07 | 02-SEP-17:00 | 3463.07 | 02-SEP-17:00 | 724.08 | 07-SEP-15:10 | 1005.90 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 26035066.89 | 6955064.42 | 19.42 | 26035066.89 | -0.0 | 0.00 | 0.17 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 1230.93 | 18-OCT-16:05 | 1230.93 | 18-OCT-16:05 | 0.00 | 18-OCT-16:40 | 323.95 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.810543E+10 | 0.216891E+10 | 1812.17 | 0.797566E+10 | 0.129765E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.284893E+10 | 0.765402E+09 | 534.73 | 0.279299E+10 | 55934316.84 | 0.00 | 0.59 | 0.00 | 4335.32 | 4335.32 | 724.08 | 1267.77 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 78562143.07 | 20742827.21 | 30.33 | 78562143.07 | 0.00 | 0.00 | 0.26 | 26-FEB-14:00 | 0.00 | 01-FEB-00:10 | 1657.51 | 26-FEB-14:00 | 1657.51 | 26-FEB-14:00 | 0.00 | 25-FEB-14:40 | 430.74 | 26-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 64949776.37 | 17303191.06 | 39.17 | 64949776.37 | 0.00 | 0.00 | 0.17 | 20-MAR-14:30 | 0.00 | 01-MAR-00:10 | 1040.45 | 20-MAR-14:30 | 1040.45 | 20-MAR-14:30 | 0.00 | 20-MAR-15:20 | 274.38 | 20-MAR-14:30 | 0.00 | 01-MAR-00:10 |
| April | 0.343582E+09 | 90287785.19 | 130.92 | 0.343582E+09 | -0.0 | 0.00 | 0.32 | 06-APR-15:20 | 0.00 | 01-APR-00:10 | 2100.30 | 06-APR-15:20 | 2100.30 | 06-APR-15:20 | 0.00 | 06-APR-14:00 | 538.14 | 06-APR-15:20 | 0.00 | 01-APR-00:10 |
| May | 0.750847E+09 | 0.195825E+09 | 223.04 | 0.750311E+09 | 535556.62 | 0.00 | 0.47 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 | 3121.25 | 19-MAY-15:10 | 3121.25 | 19-MAY-15:10 | 97.45 | 02-MAY-13:20 | 823.11 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.210745E+10 | 0.547857E+09 | 421.49 | 0.206268E+10 | 44769741.20 | 0.00 | 0.56 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 | 3555.45 | 23-JUN-13:30 | 3555.45 | 23-JUN-13:30 | 319.22 | 20-JUN-18:50 | 983.79 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.355492E+10 | 0.937265E+09 | 567.61 | 0.348765E+10 | 67277226.99 | 0.00 | 0.67 | 25-JUL-13:00 | 0.00 | 01-JUL-04:40 | 4288.42 | 25-JUL-13:00 | 4288.42 | 25-JUL-13:00 | 412.26 | 19-JUL-09:00 | 1220.16 | 17-JUL-13:50 | 0.00 | 01-JUL-00:10 |
| August | 0.301370E+10 | 0.795423E+09 | 512.41 | 0.300684E+10 | 6852397.22 | 0.00 | 0.66 | 10-AUG-14:40 | 0.00 | 01-AUG-02:50 | 4271.29 | 10-AUG-13:00 | 4271.29 | 10-AUG-13:00 | 101.57 | 01-AUG-14:30 | 1184.10 | 09-AUG-13:30 | 0.00 | 01-AUG-00:10 |
| September | 0.163177E+10 | 0.426809E+09 | 328.86 | 0.159748E+10 | 34291161.54 | 0.00 | 0.69 | 02-SEP-14:00 | 0.00 | 01-SEP-02:30 | 4491.39 | 02-SEP-14:00 | 4491.39 | 02-SEP-14:00 | 719.95 | 07-SEP-15:00 | 1247.84 | 02-SEP-14:00 | 0.00 | 01-SEP-00:10 |
| October | 0.385557E+09 | 0.100858E+09 | 135.92 | 0.385557E+09 | -0.0 | 0.00 | 0.44 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 | 2857.07 | 18-OCT-14:10 | 2857.07 | 18-OCT-14:10 | 0.00 | 15-OCT-14:50 | 732.21 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 26902954.23 | 7125206.10 | 18.33 | 26902954.23 | -0.0 | 0.00 | 0.18 | 03-NOV-14:00 | 0.00 | 01-NOV-00:10 | 1152.56 | 03-NOV-14:00 | 1152.56 | 03-NOV-14:00 | 0.00 | 03-NOV-14:20 | 301.36 | 03-NOV-14:00 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.119582E+11 | 0.313949E+10 | 2408.08 | 0.118045E+11 | 0.153726E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.355492E+10 | 0.937265E+09 | 567.61 | 0.348765E+10 | 67277226.99 | 0.00 | 0.69 | 0.00 | 4491.39 | 4491.39 | 719.95 | 1247.84 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 22416455.93 | 6001265.11 | 28.08 | 22416455.93 | -0.0 | 0.00 | 0.09 | 24-APR-18:50 | 0.00 | 01-APR-00:10 | 543.18 | 24-APR-18:50 | 543.18 | 24-APR-18:50 | 0.00 | 06-APR-15:50 | 144.69 | 24-APR-18:50 | 0.00 | 01-APR-00:10 |
| May | 0.450301E+09 | 0.118374E+09 | 164.77 | 0.450147E+09 | 154123.77 | 0.00 | 0.37 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 2265.59 | 20-MAY-16:05 | 2265.59 | 20-MAY-16:05 | 13.83 | 20-MAY-22:00 | 622.77 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.173683E+10 | 0.454160E+09 | 407.23 | 0.169492E+10 | 41904196.90 | 0.00 | 0.48 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 | 2901.25 | 29-JUN-15:10 | 2901.25 | 29-JUN-15:10 | 312.46 | 20-JUN-18:40 | 814.29 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.297001E+10 | 0.789008E+09 | 559.76 | 0.290758E+10 | 62431939.76 | 0.00 | 0.59 | 17-JUL-16:10 | 0.00 | 01-JUL-04:30 | 3481.77 | 17-JUL-16:07 | 3481.77 | 17-JUL-16:07 | 405.50 | 19-JUL-08:50 | 1033.14 | 17-JUL-16:07 | 0.00 | 01-JUL-00:10 |
| August | 0.214329E+10 | 0.574852E+09 | 488.02 | 0.213765E+10 | 5643012.73 | 0.00 | 0.55 | 06-AUG-16:02 | 0.00 | 01-AUG-02:40 | 3264.33 | 06-AUG-16:02 | 3264.33 | 06-AUG-16:02 | 81.37 | 22-AUG-14:10 | 954.24 | 06-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.826965E+09 | 0.221094E+09 | 229.92 | 0.799804E+09 | 27160579.07 | 0.00 | 0.47 | 03-SEP-16:02 | 0.00 | 01-SEP-01:30 | 2814.62 | 03-SEP-16:04 | 2814.62 | 03-SEP-16:04 | 568.48 | 07-SEP-15:10 | 810.28 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 11783911.39 | 3164760.67 | 11.67 | 11783911.39 | -0.0 | 0.00 | 0.11 | 18-OCT-16:10 | 0.00 | 01-OCT-00:10 | 652.97 | 18-OCT-16:10 | 652.97 | 18-OCT-16:10 | 0.00 | 18-OCT-13:50 | 173.34 | 18-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.816160E+10 | 0.216665E+10 | 1889.45 | 0.802431E+10 | 0.137294E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.297001E+10 | 0.789008E+09 | 559.76 | 0.290758E+10 | 62431939.76 | 0.00 | 0.59 | 0.00 | 3481.77 | 3481.77 | 568.48 | 1033.14 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 6632255.04 | 1780351.52 | 11.67 | 6632255.04 | -0.0 | 0.00 | 0.06 | 25-APR-18:50 | 0.00 | 01-APR-00:10 | 308.80 | 25-APR-18:50 | 308.80 | 25-APR-18:50 | 0.00 | 06-APR-16:40 | 82.62 | 25-APR-18:50 | 0.00 | 01-APR-00:10 |
| May | 0.333353E+09 | 87935272.32 | 143.49 | 0.333195E+09 | 157721.05 | 0.00 | 0.33 | 20-MAY-16:08 | 0.00 | 01-MAY-00:10 | 1895.29 | 20-MAY-16:05 | 1895.29 | 20-MAY-16:05 | 15.29 | 20-MAY-22:00 | 523.76 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.125145E+10 | 0.329999E+09 | 391.20 | 0.121663E+10 | 34817803.17 | 0.00 | 0.40 | 29-JUN-15:10 | 0.00 | 01-JUN-01:00 | 2294.51 | 20-JUN-17:30 | 2247.20 | 29-JUN-16:04 | 271.76 | 20-JUN-19:00 | 636.87 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.220856E+10 | 0.592979E+09 | 564.33 | 0.215581E+10 | 52755318.60 | 0.00 | 0.52 | 17-JUL-16:04 | 0.00 | 01-JUL-06:13 | 2809.30 | 17-JUL-16:04 | 2809.30 | 17-JUL-16:04 | 271.11 | 19-JUL-09:10 | 843.32 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.158947E+10 | 0.430259E+09 | 486.22 | 0.158470E+10 | 4765714.37 | 0.00 | 0.48 | 06-AUG-16:17 | 0.00 | 01-AUG-03:20 | 2614.19 | 06-AUG-16:17 | 2614.19 | 06-AUG-16:17 | 71.12 | 22-AUG-14:10 | 772.07 | 06-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.664115E+09 | 0.178117E+09 | 240.59 | 0.637055E+09 | 27059477.08 | 0.00 | 0.41 | 03-SEP-16:02 | 0.00 | 01-SEP-03:50 | 2293.17 | 03-SEP-16:02 | 2293.17 | 03-SEP-16:02 | 528.83 | 07-SEP-15:10 | 667.22 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 6030289.53 | 1624509.68 | 7.50 | 6030289.53 | -0.0 | 0.00 | 0.09 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 506.33 | 18-OCT-16:05 | 506.33 | 18-OCT-16:05 | 0.00 | 18-OCT-14:10 | 134.78 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.605961E+10 | 0.162269E+10 | 1845.01 | 0.594005E+10 | 0.119556E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.220856E+10 | 0.592979E+09 | 564.33 | 0.215581E+10 | 52755318.60 | 0.00 | 0.52 | 0.00 | 2809.30 | 2809.30 | 528.83 | 843.32 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 6727497.95 | 1805861.87 | 12.00 | 6727497.95 | -0.0 | 0.00 | 0.06 | 25-APR-18:50 | 0.00 | 01-APR-00:10 | 307.78 | 25-APR-18:50 | 307.78 | 25-APR-18:50 | 0.00 | 07-APR-16:50 | 82.35 | 25-APR-18:50 | 0.00 | 01-APR-00:10 |
| May | 0.334198E+09 | 88152322.69 | 145.33 | 0.334039E+09 | 159472.21 | 0.00 | 0.33 | 20-MAY-16:08 | 0.00 | 01-MAY-00:10 | 1892.49 | 20-MAY-16:05 | 1892.49 | 20-MAY-16:05 | 15.23 | 20-MAY-22:00 | 522.84 | 20-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.126096E+10 | 0.332395E+09 | 393.83 | 0.122598E+10 | 34976266.91 | 0.00 | 0.41 | 29-JUN-15:10 | 0.00 | 01-JUN-01:00 | 2281.19 | 20-JUN-17:30 | 2243.23 | 29-JUN-15:10 | 271.36 | 20-JUN-19:00 | 636.96 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.221828E+10 | 0.595323E+09 | 565.51 | 0.216530E+10 | 52984700.41 | 0.00 | 0.52 | 17-JUL-16:04 | 0.00 | 01-JUL-06:13 | 2798.45 | 17-JUL-16:04 | 2798.45 | 17-JUL-16:04 | 274.19 | 19-JUL-09:10 | 839.86 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.159927E+10 | 0.432728E+09 | 488.69 | 0.159447E+10 | 4806667.56 | 0.00 | 0.48 | 06-AUG-16:02 | 0.00 | 01-AUG-03:20 | 2605.12 | 06-AUG-16:17 | 2605.12 | 06-AUG-16:17 | 71.23 | 22-AUG-14:10 | 769.37 | 06-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.664998E+09 | 0.178334E+09 | 240.41 | 0.638106E+09 | 26892899.91 | 0.00 | 0.42 | 03-SEP-16:02 | 0.00 | 01-SEP-03:50 | 2283.96 | 03-SEP-16:04 | 2283.96 | 03-SEP-16:04 | 524.49 | 07-SEP-15:10 | 662.79 | 02-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 6274183.22 | 1690248.42 | 7.33 | 6274183.22 | 0.00 | 0.00 | 0.09 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 501.33 | 18-OCT-16:05 | 501.33 | 18-OCT-16:05 | 0.00 | 18-OCT-16:10 | 133.46 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.609071E+10 | 0.163043E+10 | 1853.10 | 0.597089E+10 | 0.119820E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.221828E+10 | 0.595323E+09 | 565.51 | 0.216530E+10 | 52984700.41 | 0.00 | 0.52 | 0.00 | 2798.45 | 2798.45 | 524.49 | 839.86 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 800780.38 | 215833.11 | 2.33 | 800780.38 | -0.0 | 0.00 | 0.03 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 | 183.10 | 15-JAN-13:40 | 183.10 | 15-JAN-13:40 | 0.00 | 15-JAN-13:40 | 49.28 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 |
| February | 88642080.58 | 23384595.69 | 36.08 | 88642080.58 | 0.00 | 0.00 | 0.27 | 26-FEB-14:00 | 0.00 | 01-FEB-00:10 | 1616.48 | 26-FEB-14:00 | 1616.48 | 26-FEB-14:00 | 0.00 | 25-FEB-13:40 | 419.41 | 26-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 72940235.26 | 19425230.56 | 46.29 | 72940235.26 | 0.00 | 0.00 | 0.16 | 20-MAR-15:10 | 0.00 | 01-MAR-00:10 | 964.57 | 20-MAR-15:10 | 964.57 | 20-MAR-15:10 | 0.00 | 14-MAR-14:00 | 254.44 | 20-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.260707E+09 | 68741798.33 | 124.75 | 0.260707E+09 | 0.00 | 0.00 | 0.30 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 1822.67 | 06-APR-16:10 | 1822.67 | 06-APR-16:10 | 0.00 | 25-APR-15:30 | 468.50 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.601780E+09 | 0.157554E+09 | 214.81 | 0.601426E+09 | 354108.46 | 0.00 | 0.42 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2599.70 | 19-MAY-15:10 | 2599.70 | 19-MAY-15:10 | 38.29 | 02-MAY-13:30 | 690.83 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.161555E+10 | 0.423359E+09 | 412.47 | 0.157738E+10 | 38166864.10 | 0.00 | 0.48 | 29-JUN-14:30 | 0.00 | 01-JUN-01:50 | 2843.68 | 29-JUN-14:30 | 2843.68 | 29-JUN-14:30 | 276.88 | 20-JUN-19:00 | 797.26 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.280106E+10 | 0.745756E+09 | 574.19 | 0.274276E+10 | 58298106.55 | 0.00 | 0.59 | 17-JUL-16:10 | 0.00 | 01-JUL-06:13 | 3450.01 | 25-JUL-14:40 | 3450.01 | 25-JUL-14:40 | 289.09 | 19-JUL-09:30 | 1020.66 | 17-JUL-16:04 | 0.00 | 01-JUL-00:10 |
| August | 0.245771E+10 | 0.653573E+09 | 526.11 | 0.245143E+10 | 6286647.64 | 0.00 | 0.60 | 10-AUG-14:50 | 0.00 | 01-AUG-03:40 | 3534.35 | 09-AUG-13:50 | 3534.35 | 09-AUG-13:50 | 90.94 | 22-AUG-13:50 | 996.72 | 09-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.144922E+10 | 0.380189E+09 | 355.52 | 0.141435E+10 | 34868190.52 | 0.00 | 0.63 | 02-SEP-14:10 | 0.00 | 01-SEP-05:05 | 3796.89 | 02-SEP-14:00 | 3796.89 | 02-SEP-14:00 | 680.16 | 07-SEP-15:00 | 1066.68 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.395111E+09 | 0.103412E+09 | 151.83 | 0.395111E+09 | 0.00 | 0.00 | 0.43 | 18-OCT-14:20 | 0.00 | 01-OCT-00:10 | 2630.28 | 18-OCT-14:20 | 2630.28 | 18-OCT-14:20 | 0.00 | 15-OCT-13:20 | 674.86 | 18-OCT-14:20 | 0.00 | 01-OCT-00:10 |
| November | 46089052.82 | 12219025.00 | 30.38 | 46089052.82 | 0.00 | 0.00 | 0.21 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 | 1242.48 | 03-NOV-14:10 | 1242.48 | 03-NOV-14:10 | 0.00 | 03-NOV-16:03 | 323.59 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.978961E+10 | 0.258783E+10 | 2474.77 | 0.965164E+10 | 0.137974E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.280106E+10 | 0.745756E+09 | 574.19 | 0.274276E+10 | 58298106.55 | 0.00 | 0.63 | 0.00 | 3796.89 | 3796.89 | 680.16 | 1066.68 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 996687.92 | 268558.87 | 2.50 | 996687.92 | 0.00 | 0.00 | 0.03 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 | 176.18 | 15-JAN-13:40 | 176.18 | 15-JAN-13:40 | 0.00 | 01-JAN-14:20 | 47.43 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 |
| February | 90296113.03 | 23812507.35 | 36.67 | 90296113.03 | -0.0 | 0.00 | 0.28 | 26-FEB-14:00 | 0.00 | 01-FEB-00:10 | 1640.25 | 26-FEB-14:00 | 1640.25 | 26-FEB-14:00 | 0.00 | 26-FEB-13:50 | 425.20 | 26-FEB-14:00 | 0.00 | 01-FEB-00:10 |
| March | 75848003.10 | 20193183.10 | 47.19 | 75848003.10 | 0.00 | 0.00 | 0.17 | 20-MAR-15:10 | 0.00 | 01-MAR-00:10 | 977.91 | 20-MAR-15:10 | 977.91 | 20-MAR-15:10 | 0.00 | 14-MAR-13:10 | 257.83 | 20-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.267132E+09 | 70414998.70 | 126.58 | 0.267132E+09 | 0.00 | 0.00 | 0.30 | 06-APR-16:10 | 0.00 | 01-APR-00:10 | 1822.70 | 06-APR-16:10 | 1822.70 | 06-APR-16:10 | 0.00 | 22-APR-15:30 | 468.37 | 06-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.605255E+09 | 0.158434E+09 | 216.44 | 0.604877E+09 | 378625.69 | 0.00 | 0.42 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2606.50 | 19-MAY-15:10 | 2606.50 | 19-MAY-15:10 | 43.47 | 02-MAY-13:30 | 692.24 | 19-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.162626E+10 | 0.425977E+09 | 413.66 | 0.158794E+10 | 38317882.89 | 0.00 | 0.49 | 29-JUN-14:30 | 0.00 | 01-JUN-01:40 | 2853.02 | 29-JUN-14:30 | 2853.02 | 29-JUN-14:30 | 276.65 | 20-JUN-19:00 | 799.31 | 29-JUN-14:30 | 0.00 | 01-JUN-00:10 |
| July | 0.281119E+10 | 0.748053E+09 | 574.78 | 0.275266E+10 | 58535033.67 | 0.00 | 0.60 | 17-JUL-16:10 | 0.00 | 01-JUL-06:13 | 3457.43 | 25-JUL-14:30 | 3457.43 | 25-JUL-14:30 | 291.98 | 19-JUL-09:30 | 1017.04 | 17-JUL-16:09 | 0.00 | 01-JUL-00:10 |
| August | 0.246770E+10 | 0.655886E+09 | 528.00 | 0.246138E+10 | 6318448.08 | 0.00 | 0.60 | 10-AUG-14:50 | 0.00 | 01-AUG-03:40 | 3548.18 | 09-AUG-13:40 | 3548.18 | 09-AUG-13:40 | 90.95 | 22-AUG-13:50 | 999.02 | 09-AUG-13:50 | 0.00 | 01-AUG-00:10 |
| September | 0.145391E+10 | 0.381282E+09 | 356.55 | 0.141917E+10 | 34742863.07 | 0.00 | 0.63 | 02-SEP-14:10 | 0.00 | 01-SEP-05:05 | 3808.58 | 02-SEP-14:00 | 3808.58 | 02-SEP-14:00 | 677.57 | 07-SEP-15:00 | 1068.54 | 02-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.398838E+09 | 0.104361E+09 | 152.83 | 0.398838E+09 | -0.0 | 0.00 | 0.44 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 | 2639.85 | 18-OCT-14:10 | 2639.85 | 18-OCT-14:10 | 0.00 | 16-OCT-14:50 | 676.92 | 18-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 47165328.46 | 12500640.48 | 30.88 | 47165328.46 | 0.00 | 0.00 | 0.21 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 | 1257.62 | 03-NOV-14:10 | 1257.62 | 03-NOV-14:10 | 0.00 | 03-NOV-12:30 | 327.35 | 03-NOV-14:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.984460E+10 | 0.260118E+10 | 2486.08 | 0.970630E+10 | 0.138293E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.281119E+10 | 0.748053E+09 | 574.78 | 0.275266E+10 | 58535033.67 | 0.00 | 0.63 | 0.00 | 3808.58 | 3808.58 | 677.57 | 1068.54 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 245.63 | 276.21 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 347.14 | 203.02 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 307.57 | 176.49 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 271.83 | 124.22 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 242.19 | 98.01 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 265.97 | 68.84 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 318.17 | 55.44 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 357.16 | 63.39 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 378.37 | 91.75 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 363.33 | 133.40 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 299.49 | 171.37 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 240.51 | 235.81 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 302.74 | 141.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 240.51 | 55.44 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 378.37 | 276.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.56 | 20.54 | 30.02 | 25.73 | 205.83 | 0.00 | 0.00 | 0.00 |
| February | 85.65 | 42.15 | 43.50 | 67.09 | 147.73 | 0.00 | 0.00 | 0.00 |
| March | 109.96 | 40.39 | 69.57 | 91.93 | 119.22 | 0.00 | 0.00 | 0.00 |
| April | 143.29 | 63.30 | 79.99 | 147.58 | 80.91 | 0.00 | 0.00 | 0.00 |
| May | 177.27 | 80.87 | 96.40 | 199.12 | 62.85 | 0.00 | 0.00 | 0.00 |
| June | 192.72 | 88.49 | 104.23 | 236.84 | 43.66 | 0.00 | 0.00 | 0.00 |
| July | 197.63 | 99.91 | 97.72 | 261.50 | 36.28 | 0.00 | 0.00 | 0.00 |
| August | 167.45 | 81.96 | 85.49 | 214.66 | 41.05 | 0.00 | 0.00 | 0.00 |
| September | 134.82 | 68.12 | 66.70 | 158.35 | 61.26 | 0.00 | 0.00 | 0.00 |
| October | 96.55 | 47.99 | 48.56 | 93.85 | 92.18 | 0.00 | 0.00 | 0.00 |
| November | 68.23 | 33.85 | 34.38 | 54.13 | 125.94 | 0.00 | 0.00 | 0.00 |
| December | 45.77 | 19.28 | 26.48 | 24.81 | 174.96 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 122.66 | 57.29 | 65.37 | 131.63 | 99.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.77 | 19.28 | 26.48 | 24.81 | 36.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 197.63 | 99.91 | 104.23 | 261.50 | 205.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.56 | 20.54 | 30.02 | 26.53 | 203.21 | 0.00 | 0.00 | 0.00 |
| February | 85.65 | 42.15 | 43.50 | 69.21 | 144.65 | 0.00 | 0.00 | 0.00 |
| March | 109.96 | 40.39 | 69.57 | 94.04 | 116.93 | 0.00 | 0.00 | 0.00 |
| April | 143.29 | 63.30 | 79.99 | 150.18 | 78.84 | 0.00 | 0.00 | 0.00 |
| May | 177.27 | 80.87 | 96.40 | 201.36 | 61.38 | 0.00 | 0.00 | 0.00 |
| June | 192.72 | 88.49 | 104.23 | 238.42 | 42.68 | 0.00 | 0.00 | 0.00 |
| July | 197.63 | 99.91 | 97.72 | 262.63 | 35.69 | 0.00 | 0.00 | 0.00 |
| August | 167.45 | 81.96 | 85.49 | 216.59 | 39.81 | 0.00 | 0.00 | 0.00 |
| September | 134.82 | 68.12 | 66.70 | 161.79 | 57.66 | 0.00 | 0.00 | 0.00 |
| October | 96.55 | 47.99 | 48.56 | 98.60 | 85.08 | 0.00 | 0.00 | 0.00 |
| November | 68.23 | 33.85 | 34.38 | 56.53 | 121.30 | 0.00 | 0.00 | 0.00 |
| December | 45.77 | 19.28 | 26.48 | 25.70 | 172.29 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 122.66 | 57.29 | 65.37 | 133.79 | 96.47 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.77 | 19.28 | 26.48 | 25.70 | 35.69 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 197.63 | 99.91 | 104.23 | 262.63 | 203.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.96 | 323.77 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 9.92 | 234.05 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 34.38 | 182.03 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 61.66 | 119.76 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 108.07 | 89.18 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 158.82 | 58.51 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 167.60 | 50.02 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 123.90 | 57.64 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 73.83 | 88.22 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 30.33 | 132.20 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.89 | 195.12 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.75 | 276.70 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 65.18 | 150.30 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.75 | 50.02 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 167.60 | 323.77 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 252.40 | 247.64 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 354.60 | 181.27 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 313.47 | 160.11 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 273.86 | 117.58 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 241.16 | 96.14 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 259.02 | 77.20 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 306.82 | 68.91 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 348.44 | 76.97 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 370.95 | 104.20 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 361.66 | 137.76 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 301.51 | 164.65 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 247.73 | 210.97 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 302.22 | 136.82 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 241.16 | 68.91 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 370.95 | 247.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.86 | 25.76 | 30.10 | 31.94 | 176.95 | 0.00 | 0.00 | 0.00 |
| February | 87.16 | 43.40 | 43.76 | 70.43 | 128.25 | 0.00 | 0.00 | 0.00 |
| March | 116.86 | 48.40 | 68.45 | 103.91 | 103.79 | 0.00 | 0.00 | 0.00 |
| April | 148.93 | 73.87 | 75.06 | 155.01 | 73.45 | 0.00 | 0.00 | 0.00 |
| May | 164.50 | 73.25 | 91.26 | 180.41 | 59.54 | 0.00 | 0.00 | 0.00 |
| June | 212.79 | 109.51 | 103.27 | 256.79 | 45.11 | 0.00 | 0.00 | 0.00 |
| July | 223.55 | 126.48 | 97.07 | 285.80 | 41.27 | 0.00 | 0.00 | 0.00 |
| August | 194.09 | 108.08 | 86.00 | 241.69 | 46.44 | 0.00 | 0.00 | 0.00 |
| September | 137.23 | 70.73 | 66.50 | 154.36 | 65.57 | 0.00 | 0.00 | 0.00 |
| October | 97.73 | 49.25 | 48.47 | 92.47 | 91.24 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 29.08 | 33.23 | 44.60 | 116.74 | 0.00 | 0.00 | 0.00 |
| December | 46.05 | 19.81 | 26.24 | 25.33 | 151.07 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 129.14 | 64.91 | 64.23 | 137.27 | 91.50 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.05 | 19.81 | 26.24 | 25.33 | 41.27 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 223.55 | 126.48 | 103.27 | 285.80 | 176.95 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.86 | 25.76 | 30.10 | 30.07 | 194.85 | 0.00 | 0.00 | 0.00 |
| February | 87.16 | 43.40 | 43.76 | 68.49 | 140.27 | 0.00 | 0.00 | 0.00 |
| March | 116.86 | 48.40 | 68.45 | 101.62 | 111.84 | 0.00 | 0.00 | 0.00 |
| April | 148.93 | 73.87 | 75.06 | 155.41 | 75.14 | 0.00 | 0.00 | 0.00 |
| May | 164.50 | 73.25 | 91.26 | 182.70 | 58.53 | 0.00 | 0.00 | 0.00 |
| June | 212.79 | 109.51 | 103.27 | 262.77 | 39.24 | 0.00 | 0.00 | 0.00 |
| July | 223.55 | 126.48 | 97.07 | 294.74 | 32.68 | 0.00 | 0.00 | 0.00 |
| August | 194.09 | 108.08 | 86.00 | 249.54 | 37.27 | 0.00 | 0.00 | 0.00 |
| September | 137.23 | 70.73 | 66.50 | 162.47 | 54.29 | 0.00 | 0.00 | 0.00 |
| October | 97.73 | 49.25 | 48.47 | 97.65 | 81.04 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 29.08 | 33.23 | 45.68 | 116.48 | 0.00 | 0.00 | 0.00 |
| December | 46.05 | 19.81 | 26.24 | 23.56 | 166.62 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 129.14 | 64.91 | 64.23 | 139.96 | 92.19 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.05 | 19.81 | 26.24 | 23.56 | 32.68 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 223.55 | 126.48 | 103.27 | 294.74 | 194.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.93 | 323.94 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 9.76 | 233.99 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 34.07 | 181.97 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 61.24 | 119.57 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 107.80 | 88.58 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 157.55 | 58.28 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 166.63 | 49.82 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 122.84 | 57.73 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 73.17 | 88.12 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 29.92 | 131.96 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.84 | 194.95 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.74 | 276.73 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 64.71 | 150.17 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.74 | 49.82 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 166.63 | 323.94 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.87 | 328.78 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 9.53 | 237.72 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 33.54 | 185.05 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 60.96 | 121.88 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 107.74 | 90.38 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 158.02 | 59.69 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 168.35 | 49.92 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 124.20 | 58.17 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 73.68 | 89.69 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 29.64 | 134.68 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.63 | 198.02 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.68 | 280.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 64.91 | 152.60 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.68 | 49.92 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 168.35 | 328.78 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.87 | 328.79 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 9.52 | 237.72 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 33.52 | 185.05 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 60.94 | 121.87 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 107.72 | 90.34 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 157.94 | 59.69 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 168.31 | 49.92 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 124.14 | 58.20 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 73.63 | 89.71 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 29.61 | 134.69 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.63 | 198.01 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.68 | 280.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 64.88 | 152.60 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.68 | 49.92 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 168.31 | 328.79 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 244.17 | 280.87 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 345.32 | 206.84 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 305.79 | 180.11 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 270.24 | 127.21 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 241.35 | 99.74 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 265.21 | 70.48 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 318.90 | 55.44 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 357.44 | 63.91 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 377.55 | 93.99 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 361.43 | 137.43 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 297.14 | 176.02 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 239.10 | 239.74 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 301.61 | 144.10 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 239.10 | 55.44 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 377.55 | 280.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 244.53 | 279.72 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 345.81 | 205.82 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 306.16 | 179.36 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 270.38 | 126.89 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 241.20 | 99.74 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 264.60 | 71.07 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 318.32 | 55.98 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 356.92 | 64.49 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 377.00 | 94.78 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 361.19 | 137.79 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 297.13 | 175.84 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 239.49 | 238.66 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 301.53 | 143.97 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 239.49 | 55.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 377.00 | 279.72 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 241.61 | 284.91 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 340.77 | 212.02 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 300.21 | 186.81 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 261.69 | 138.45 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 232.41 | 109.35 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 259.88 | 74.62 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 315.73 | 56.87 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 354.84 | 64.83 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.73 | 93.53 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 360.27 | 136.25 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 295.79 | 176.31 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 236.99 | 242.10 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 297.64 | 147.78 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 232.41 | 56.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.73 | 284.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.56 | 20.54 | 30.02 | 24.69 | 213.11 | 0.00 | 0.00 | 0.00 |
| February | 85.65 | 42.15 | 43.50 | 64.33 | 154.75 | 0.00 | 0.00 | 0.00 |
| March | 109.96 | 40.39 | 69.57 | 87.53 | 126.40 | 0.00 | 0.00 | 0.00 |
| April | 143.29 | 63.30 | 79.99 | 140.63 | 90.07 | 0.00 | 0.00 | 0.00 |
| May | 177.27 | 80.87 | 96.40 | 192.08 | 69.85 | 0.00 | 0.00 | 0.00 |
| June | 192.72 | 88.49 | 104.23 | 232.48 | 47.22 | 0.00 | 0.00 | 0.00 |
| July | 197.63 | 99.91 | 97.72 | 259.85 | 37.26 | 0.00 | 0.00 | 0.00 |
| August | 167.45 | 81.96 | 85.49 | 213.23 | 42.01 | 0.00 | 0.00 | 0.00 |
| September | 134.82 | 68.12 | 66.70 | 156.94 | 62.56 | 0.00 | 0.00 | 0.00 |
| October | 96.55 | 47.99 | 48.56 | 92.37 | 94.29 | 0.00 | 0.00 | 0.00 |
| November | 68.23 | 33.85 | 34.38 | 52.67 | 129.95 | 0.00 | 0.00 | 0.00 |
| December | 45.77 | 19.28 | 26.48 | 23.86 | 180.24 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 122.66 | 57.29 | 65.37 | 128.73 | 103.80 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.77 | 19.28 | 26.48 | 23.86 | 37.26 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 197.63 | 99.91 | 104.23 | 259.85 | 213.11 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.56 | 20.54 | 30.02 | 25.68 | 210.29 | 0.00 | 0.00 | 0.00 |
| February | 85.65 | 42.15 | 43.50 | 67.04 | 150.96 | 0.00 | 0.00 | 0.00 |
| March | 109.96 | 40.39 | 69.57 | 90.62 | 123.25 | 0.00 | 0.00 | 0.00 |
| April | 143.29 | 63.30 | 79.99 | 144.18 | 86.67 | 0.00 | 0.00 | 0.00 |
| May | 177.27 | 80.87 | 96.40 | 194.07 | 68.60 | 0.00 | 0.00 | 0.00 |
| June | 192.72 | 88.49 | 104.23 | 233.24 | 47.01 | 0.00 | 0.00 | 0.00 |
| July | 197.63 | 99.91 | 97.72 | 260.77 | 36.96 | 0.00 | 0.00 | 0.00 |
| August | 167.45 | 81.96 | 85.49 | 214.75 | 41.34 | 0.00 | 0.00 | 0.00 |
| September | 134.82 | 68.12 | 66.70 | 160.04 | 59.79 | 0.00 | 0.00 | 0.00 |
| October | 96.55 | 47.99 | 48.56 | 96.87 | 88.14 | 0.00 | 0.00 | 0.00 |
| November | 68.23 | 33.85 | 34.38 | 55.48 | 124.86 | 0.00 | 0.00 | 0.00 |
| December | 45.77 | 19.28 | 26.48 | 24.88 | 177.59 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 122.66 | 57.29 | 65.37 | 130.96 | 101.12 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.77 | 19.28 | 26.48 | 24.88 | 36.96 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 197.63 | 99.91 | 104.23 | 260.77 | 210.29 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.74 | 334.53 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.33 | 244.42 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.60 | 191.96 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 53.98 | 132.25 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 97.28 | 99.60 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 150.78 | 64.15 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 165.05 | 51.62 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 121.54 | 59.80 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 71.94 | 91.39 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 28.58 | 136.90 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.30 | 200.66 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.58 | 284.86 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 61.72 | 157.35 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.58 | 51.62 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 165.05 | 334.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 241.35 | 284.92 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 340.27 | 211.77 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 299.37 | 186.63 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 260.57 | 138.32 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 231.64 | 108.62 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 258.96 | 74.30 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 314.98 | 56.60 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 354.08 | 64.68 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.01 | 93.35 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 359.58 | 135.98 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 295.46 | 175.92 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 236.83 | 241.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 296.99 | 147.53 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 231.64 | 56.60 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.01 | 284.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.86 | 25.76 | 30.10 | 28.44 | 204.31 | 0.00 | 0.00 | 0.00 |
| February | 87.16 | 43.40 | 43.76 | 64.08 | 150.51 | 0.00 | 0.00 | 0.00 |
| March | 116.86 | 48.40 | 68.45 | 95.27 | 121.01 | 0.00 | 0.00 | 0.00 |
| April | 148.93 | 73.87 | 75.06 | 145.60 | 86.18 | 0.00 | 0.00 | 0.00 |
| May | 164.50 | 73.25 | 91.26 | 173.35 | 66.81 | 0.00 | 0.00 | 0.00 |
| June | 212.79 | 109.51 | 103.27 | 256.87 | 43.31 | 0.00 | 0.00 | 0.00 |
| July | 223.55 | 126.48 | 97.07 | 291.91 | 33.97 | 0.00 | 0.00 | 0.00 |
| August | 194.09 | 108.08 | 86.00 | 246.20 | 39.11 | 0.00 | 0.00 | 0.00 |
| September | 137.23 | 70.73 | 66.50 | 157.54 | 58.72 | 0.00 | 0.00 | 0.00 |
| October | 97.73 | 49.25 | 48.47 | 91.44 | 89.95 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 29.08 | 33.23 | 42.69 | 125.56 | 0.00 | 0.00 | 0.00 |
| December | 46.05 | 19.81 | 26.24 | 22.20 | 174.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 129.14 | 64.91 | 64.23 | 135.04 | 99.31 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.05 | 19.81 | 26.24 | 22.20 | 33.97 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 223.55 | 126.48 | 103.27 | 291.91 | 204.31 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.86 | 25.76 | 30.10 | 29.10 | 201.23 | 0.00 | 0.00 | 0.00 |
| February | 87.16 | 43.40 | 43.76 | 66.35 | 146.30 | 0.00 | 0.00 | 0.00 |
| March | 116.86 | 48.40 | 68.45 | 98.21 | 117.56 | 0.00 | 0.00 | 0.00 |
| April | 148.93 | 73.87 | 75.06 | 149.06 | 82.80 | 0.00 | 0.00 | 0.00 |
| May | 164.50 | 73.25 | 91.26 | 175.24 | 65.51 | 0.00 | 0.00 | 0.00 |
| June | 212.79 | 109.51 | 103.27 | 257.57 | 43.09 | 0.00 | 0.00 | 0.00 |
| July | 223.55 | 126.48 | 97.07 | 292.82 | 33.65 | 0.00 | 0.00 | 0.00 |
| August | 194.09 | 108.08 | 86.00 | 247.67 | 38.48 | 0.00 | 0.00 | 0.00 |
| September | 137.23 | 70.73 | 66.50 | 160.59 | 56.12 | 0.00 | 0.00 | 0.00 |
| October | 97.73 | 49.25 | 48.47 | 95.87 | 83.80 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 29.08 | 33.23 | 44.71 | 119.69 | 0.00 | 0.00 | 0.00 |
| December | 46.05 | 19.81 | 26.24 | 22.78 | 171.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 129.14 | 64.91 | 64.23 | 137.06 | 96.47 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.05 | 19.81 | 26.24 | 22.78 | 33.65 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 223.55 | 126.48 | 103.27 | 292.82 | 201.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.71 | 334.73 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.12 | 244.26 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.23 | 191.75 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 52.89 | 132.20 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 96.56 | 98.98 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 149.74 | 63.83 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 164.19 | 51.28 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 120.64 | 59.69 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 71.12 | 91.28 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 28.04 | 136.52 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.25 | 200.40 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.57 | 284.90 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 61.17 | 157.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.57 | 51.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 164.19 | 334.73 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.67 | 338.96 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.09 | 247.30 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.23 | 193.95 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 53.94 | 133.66 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 97.83 | 100.21 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 151.51 | 64.36 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 166.56 | 51.09 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 122.52 | 59.84 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 71.93 | 92.91 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 27.61 | 140.26 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.02 | 203.75 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.52 | 288.86 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 61.87 | 159.27 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.52 | 51.09 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 166.56 | 338.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.67 | 338.98 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.08 | 247.29 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.21 | 193.94 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 53.85 | 133.73 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 97.78 | 100.19 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 151.47 | 64.35 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 166.53 | 51.08 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 122.48 | 59.84 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 71.87 | 92.94 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 27.58 | 140.26 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.01 | 203.73 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.52 | 288.86 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 61.84 | 159.27 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.52 | 51.08 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 166.53 | 338.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 240.12 | 289.53 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 339.10 | 215.69 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 298.60 | 190.44 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 260.49 | 141.75 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 232.43 | 110.20 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 260.61 | 74.85 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 317.14 | 56.37 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 355.69 | 64.81 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.26 | 95.50 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 358.45 | 140.43 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 293.24 | 181.64 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 235.46 | 246.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 296.87 | 150.37 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 232.43 | 56.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.26 | 289.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 240.10 | 289.54 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 339.07 | 215.69 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 298.54 | 190.47 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 260.43 | 141.78 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 232.40 | 110.17 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 260.58 | 74.84 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 317.11 | 56.36 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 355.66 | 64.81 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.23 | 95.51 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 358.42 | 140.42 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 293.22 | 181.62 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 235.45 | 246.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 296.84 | 150.37 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 232.40 | 56.36 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.23 | 289.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 241.86 | 277.21 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 340.29 | 205.39 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 299.27 | 180.25 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 261.71 | 130.69 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 231.89 | 103.57 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 259.62 | 68.99 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 313.37 | 53.82 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 353.08 | 60.63 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.38 | 86.70 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 362.25 | 125.42 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 296.80 | 168.46 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 237.42 | 234.94 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 297.39 | 141.11 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 231.89 | 53.82 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.38 | 277.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.56 | 20.54 | 30.02 | 24.42 | 207.43 | 0.00 | 0.00 | 0.00 |
| February | 85.65 | 42.15 | 43.50 | 63.58 | 149.67 | 0.00 | 0.00 | 0.00 |
| March | 109.96 | 40.39 | 69.57 | 86.60 | 121.60 | 0.00 | 0.00 | 0.00 |
| April | 143.29 | 63.30 | 79.99 | 140.43 | 84.68 | 0.00 | 0.00 | 0.00 |
| May | 177.27 | 80.87 | 96.40 | 191.47 | 65.75 | 0.00 | 0.00 | 0.00 |
| June | 192.72 | 88.49 | 104.23 | 232.22 | 43.40 | 0.00 | 0.00 | 0.00 |
| July | 197.63 | 99.91 | 97.72 | 258.25 | 35.16 | 0.00 | 0.00 | 0.00 |
| August | 167.45 | 81.96 | 85.49 | 212.06 | 39.11 | 0.00 | 0.00 | 0.00 |
| September | 134.82 | 68.12 | 66.70 | 156.44 | 57.58 | 0.00 | 0.00 | 0.00 |
| October | 96.55 | 47.99 | 48.56 | 93.04 | 86.26 | 0.00 | 0.00 | 0.00 |
| November | 68.23 | 33.85 | 34.38 | 52.61 | 123.88 | 0.00 | 0.00 | 0.00 |
| December | 45.77 | 19.28 | 26.48 | 23.70 | 174.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 122.66 | 57.29 | 65.37 | 128.24 | 98.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.77 | 19.28 | 26.48 | 23.70 | 35.16 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 197.63 | 99.91 | 104.23 | 258.25 | 207.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 50.56 | 20.54 | 30.02 | 25.88 | 204.92 | 0.00 | 0.00 | 0.00 |
| February | 85.65 | 42.15 | 43.50 | 67.25 | 146.61 | 0.00 | 0.00 | 0.00 |
| March | 109.96 | 40.39 | 69.57 | 90.64 | 119.36 | 0.00 | 0.00 | 0.00 |
| April | 143.29 | 63.30 | 79.99 | 144.14 | 82.92 | 0.00 | 0.00 | 0.00 |
| May | 177.27 | 80.87 | 96.40 | 193.80 | 65.09 | 0.00 | 0.00 | 0.00 |
| June | 192.72 | 88.49 | 104.23 | 233.32 | 43.31 | 0.00 | 0.00 | 0.00 |
| July | 197.63 | 99.91 | 97.72 | 259.51 | 34.96 | 0.00 | 0.00 | 0.00 |
| August | 167.45 | 81.96 | 85.49 | 214.33 | 38.50 | 0.00 | 0.00 | 0.00 |
| September | 134.82 | 68.12 | 66.70 | 160.31 | 55.76 | 0.00 | 0.00 | 0.00 |
| October | 96.55 | 47.99 | 48.56 | 98.06 | 82.66 | 0.00 | 0.00 | 0.00 |
| November | 68.23 | 33.85 | 34.38 | 55.92 | 120.40 | 0.00 | 0.00 | 0.00 |
| December | 45.77 | 19.28 | 26.48 | 25.17 | 172.49 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 122.66 | 57.29 | 65.37 | 131.02 | 97.08 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.77 | 19.28 | 26.48 | 25.17 | 34.96 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 197.63 | 99.91 | 104.23 | 259.51 | 204.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.82 | 326.15 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.66 | 237.84 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 31.00 | 186.22 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 54.18 | 126.76 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 97.44 | 94.76 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 152.22 | 59.79 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 164.03 | 49.38 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 121.47 | 56.06 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 72.71 | 85.55 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 30.47 | 128.74 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.73 | 193.64 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.68 | 276.79 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 62.11 | 151.49 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.68 | 49.38 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 164.03 | 326.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 241.44 | 277.12 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 339.49 | 204.87 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 298.04 | 179.75 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 259.93 | 130.01 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 230.29 | 102.38 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 257.47 | 68.30 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 311.76 | 53.28 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 351.47 | 60.20 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 374.00 | 86.14 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 361.00 | 124.84 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 296.36 | 167.81 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 237.14 | 234.74 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 296.18 | 140.56 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 230.29 | 53.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 374.00 | 277.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.86 | 25.76 | 30.10 | 28.78 | 198.96 | 0.00 | 0.00 | 0.00 |
| February | 87.16 | 43.40 | 43.76 | 64.17 | 146.18 | 0.00 | 0.00 | 0.00 |
| March | 116.86 | 48.40 | 68.45 | 95.03 | 116.67 | 0.00 | 0.00 | 0.00 |
| April | 148.93 | 73.87 | 75.06 | 145.75 | 81.12 | 0.00 | 0.00 | 0.00 |
| May | 164.50 | 73.25 | 91.26 | 173.03 | 63.11 | 0.00 | 0.00 | 0.00 |
| June | 212.79 | 109.51 | 103.27 | 256.84 | 40.26 | 0.00 | 0.00 | 0.00 |
| July | 223.55 | 126.48 | 97.07 | 290.28 | 32.26 | 0.00 | 0.00 | 0.00 |
| August | 194.09 | 108.08 | 86.00 | 245.09 | 36.72 | 0.00 | 0.00 | 0.00 |
| September | 137.23 | 70.73 | 66.50 | 157.57 | 54.44 | 0.00 | 0.00 | 0.00 |
| October | 97.73 | 49.25 | 48.47 | 92.90 | 82.95 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 29.08 | 33.23 | 43.63 | 120.26 | 0.00 | 0.00 | 0.00 |
| December | 46.05 | 19.81 | 26.24 | 22.61 | 169.54 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 129.14 | 64.91 | 64.23 | 135.04 | 95.02 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.05 | 19.81 | 26.24 | 22.61 | 32.26 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 223.55 | 126.48 | 103.27 | 290.28 | 198.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.86 | 25.76 | 30.10 | 29.60 | 195.91 | 0.00 | 0.00 | 0.00 |
| February | 87.16 | 43.40 | 43.76 | 66.90 | 142.17 | 0.00 | 0.00 | 0.00 |
| March | 116.86 | 48.40 | 68.45 | 98.69 | 113.85 | 0.00 | 0.00 | 0.00 |
| April | 148.93 | 73.87 | 75.06 | 149.19 | 79.12 | 0.00 | 0.00 | 0.00 |
| May | 164.50 | 73.25 | 91.26 | 175.16 | 62.25 | 0.00 | 0.00 | 0.00 |
| June | 212.79 | 109.51 | 103.27 | 257.79 | 40.14 | 0.00 | 0.00 | 0.00 |
| July | 223.55 | 126.48 | 97.07 | 291.53 | 31.99 | 0.00 | 0.00 | 0.00 |
| August | 194.09 | 108.08 | 86.00 | 247.20 | 36.10 | 0.00 | 0.00 | 0.00 |
| September | 137.23 | 70.73 | 66.50 | 161.21 | 52.45 | 0.00 | 0.00 | 0.00 |
| October | 97.73 | 49.25 | 48.47 | 97.54 | 78.59 | 0.00 | 0.00 | 0.00 |
| November | 62.31 | 29.08 | 33.23 | 45.49 | 115.43 | 0.00 | 0.00 | 0.00 |
| December | 46.05 | 19.81 | 26.24 | 23.32 | 166.56 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 129.14 | 64.91 | 64.23 | 137.36 | 92.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.05 | 19.81 | 26.24 | 23.32 | 31.99 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 223.55 | 126.48 | 103.27 | 291.53 | 195.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.77 | 326.34 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.31 | 237.48 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.38 | 185.76 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 52.47 | 126.11 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 96.02 | 93.75 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 149.92 | 59.16 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 162.28 | 48.71 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 119.56 | 55.61 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 71.26 | 84.89 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 29.67 | 127.78 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.62 | 193.32 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.65 | 276.83 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 61.07 | 150.99 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.65 | 48.71 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 162.28 | 326.34 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.76 | 331.08 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.51 | 240.91 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.82 | 188.45 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 54.65 | 128.04 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 98.27 | 95.86 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 152.97 | 60.58 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 165.53 | 49.49 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 122.52 | 56.72 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 73.25 | 86.65 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 30.37 | 130.28 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.58 | 196.48 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.62 | 281.12 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 62.49 | 153.48 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.62 | 49.49 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 165.53 | 331.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 36.72 | 0.00 | 36.72 | 0.75 | 331.09 | 0.00 | 0.00 | 0.00 |
| February | 51.84 | 0.00 | 51.84 | 8.49 | 240.88 | 0.00 | 0.00 | 0.00 |
| March | 84.22 | 0.00 | 84.22 | 30.77 | 188.41 | 0.00 | 0.00 | 0.00 |
| April | 96.31 | 0.73 | 95.59 | 54.47 | 128.02 | 0.00 | 0.00 | 0.00 |
| May | 126.01 | 7.38 | 118.63 | 98.13 | 95.79 | 0.00 | 0.00 | 0.00 |
| June | 146.66 | 16.75 | 129.91 | 152.80 | 60.55 | 0.00 | 0.00 | 0.00 |
| July | 133.96 | 12.38 | 121.58 | 165.43 | 49.45 | 0.00 | 0.00 | 0.00 |
| August | 108.61 | 3.92 | 104.69 | 122.39 | 56.70 | 0.00 | 0.00 | 0.00 |
| September | 80.58 | 0.07 | 80.51 | 73.13 | 86.61 | 0.00 | 0.00 | 0.00 |
| October | 58.72 | 0.00 | 58.72 | 30.31 | 130.20 | 0.00 | 0.00 | 0.00 |
| November | 39.92 | 0.00 | 39.92 | 7.57 | 196.45 | 0.00 | 0.00 | 0.00 |
| December | 30.79 | 0.00 | 30.79 | 0.62 | 281.12 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 83.03 | 3.45 | 79.58 | 62.40 | 153.45 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.79 | 0.00 | 30.79 | 0.62 | 49.45 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 146.66 | 16.75 | 129.91 | 165.43 | 331.09 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 240.43 | 281.83 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 338.88 | 208.93 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 298.17 | 183.33 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 261.29 | 132.91 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 232.00 | 104.89 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 260.37 | 69.91 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 314.88 | 54.11 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 354.02 | 61.44 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.31 | 88.53 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 361.04 | 128.63 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 295.27 | 171.99 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 235.92 | 238.94 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 296.95 | 143.56 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 232.00 | 54.11 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.31 | 281.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 258.36 | 184.33 | 74.03 | 240.40 | 281.82 | 0.00 | 0.00 | 0.00 |
| February | 328.72 | 236.23 | 92.49 | 338.83 | 208.89 | 0.00 | 0.00 | 0.00 |
| March | 290.25 | 161.09 | 129.17 | 298.08 | 183.30 | 0.00 | 0.00 | 0.00 |
| April | 242.27 | 118.72 | 123.56 | 261.16 | 132.87 | 0.00 | 0.00 | 0.00 |
| May | 211.74 | 71.21 | 140.53 | 231.87 | 104.80 | 0.00 | 0.00 | 0.00 |
| June | 209.32 | 61.24 | 148.09 | 260.23 | 69.86 | 0.00 | 0.00 | 0.00 |
| July | 226.59 | 84.45 | 142.14 | 314.79 | 54.07 | 0.00 | 0.00 | 0.00 |
| August | 262.98 | 130.17 | 132.81 | 353.92 | 61.41 | 0.00 | 0.00 | 0.00 |
| September | 299.71 | 184.64 | 115.07 | 375.22 | 88.50 | 0.00 | 0.00 | 0.00 |
| October | 313.62 | 217.80 | 95.81 | 360.96 | 128.60 | 0.00 | 0.00 | 0.00 |
| November | 281.63 | 203.64 | 77.98 | 295.24 | 171.94 | 0.00 | 0.00 | 0.00 |
| December | 245.72 | 177.39 | 68.32 | 235.90 | 238.93 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 263.78 | 152.00 | 111.77 | 296.86 | 143.52 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 209.32 | 61.24 | 68.32 | 231.87 | 54.07 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 328.72 | 236.23 | 148.09 | 375.22 | 281.82 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 13.40 | 6.18 | 7.22 | 6.94 | 47.93 | 0.00 | 0.00 | 0.00 |
| February | 20.91 | 10.41 | 10.50 | 15.56 | 35.66 | 0.00 | 0.00 | 0.00 |
| March | 28.04 | 11.61 | 16.43 | 22.99 | 28.93 | 20.33 | 0.00 | 0.00 |
| April | 35.74 | 17.73 | 18.01 | 35.05 | 20.79 | 68.17 | 0.00 | 0.00 |
| May | 39.47 | 17.58 | 21.90 | 41.14 | 16.62 | 82.33 | 0.00 | 0.00 |
| June | 51.06 | 26.28 | 24.78 | 60.65 | 11.09 | 180.67 | 0.00 | 0.00 |
| July | 53.64 | 30.35 | 23.29 | 68.52 | 9.06 | 220.17 | 0.00 | 0.00 |
| August | 46.57 | 25.93 | 20.64 | 57.97 | 10.17 | 199.00 | 0.00 | 0.00 |
| September | 32.93 | 16.97 | 15.96 | 37.55 | 14.45 | 137.00 | 0.00 | 0.00 |
| October | 23.45 | 11.82 | 11.63 | 22.51 | 21.07 | 115.67 | 0.00 | 0.00 |
| November | 14.95 | 6.98 | 7.97 | 10.47 | 29.55 | 36.17 | 0.00 | 0.00 |
| December | 11.05 | 4.75 | 6.30 | 5.42 | 41.12 | 0.33 | 0.00 | 0.00 |
| Annual Sum or Average | 30.99 | 15.58 | 15.41 | 32.16 | 23.83 | 1059.83 | 0.00 | 0.00 |
| Minimum of Months | 11.05 | 4.75 | 6.30 | 5.42 | 9.06 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 53.64 | 30.35 | 24.78 | 68.52 | 47.93 | 220.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.92 | 18.41 | 21.51 | 22.81 | 126.20 | 0.00 | 0.00 | 0.00 |
| February | 62.29 | 31.01 | 31.27 | 50.10 | 93.49 | 0.00 | 0.00 | 0.00 |
| March | 83.51 | 34.59 | 48.92 | 73.81 | 76.77 | 0.00 | 0.00 | 0.00 |
| April | 106.43 | 52.79 | 53.64 | 110.53 | 54.56 | 0.00 | 0.00 | 0.00 |
| May | 117.56 | 52.35 | 65.22 | 129.00 | 43.75 | 0.00 | 0.00 | 0.00 |
| June | 152.07 | 78.26 | 73.80 | 183.40 | 31.61 | 0.00 | 0.00 | 0.00 |
| July | 159.76 | 90.38 | 69.37 | 204.47 | 27.51 | 0.00 | 0.00 | 0.00 |
| August | 138.70 | 77.24 | 61.46 | 173.17 | 30.87 | 0.00 | 0.00 | 0.00 |
| September | 98.07 | 50.55 | 47.52 | 112.46 | 43.36 | 0.00 | 0.00 | 0.00 |
| October | 69.84 | 35.20 | 34.64 | 67.78 | 61.68 | 0.00 | 0.00 | 0.00 |
| November | 44.53 | 20.78 | 23.75 | 32.60 | 81.96 | 0.00 | 0.00 | 0.00 |
| December | 32.91 | 14.16 | 18.75 | 17.71 | 109.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.29 | 46.39 | 45.90 | 98.42 | 65.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 32.91 | 14.16 | 18.75 | 17.71 | 27.51 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 159.76 | 90.38 | 73.80 | 204.47 | 126.20 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 13.40 | 6.18 | 7.22 | 6.59 | 51.02 | 165.50 | 0.00 | 0.00 |
| February | 20.91 | 10.41 | 10.50 | 15.04 | 37.90 | 122.50 | 0.00 | 0.00 |
| March | 28.04 | 11.61 | 16.43 | 22.31 | 30.82 | 207.50 | 0.00 | 0.00 |
| April | 35.74 | 17.73 | 18.01 | 34.35 | 22.36 | 281.50 | 0.00 | 0.00 |
| May | 39.47 | 17.58 | 21.90 | 40.57 | 17.63 | 194.17 | 0.00 | 0.00 |
| June | 51.06 | 26.28 | 24.78 | 60.04 | 11.75 | 291.67 | 0.00 | 0.00 |
| July | 53.64 | 30.35 | 23.29 | 68.44 | 9.37 | 305.33 | 0.00 | 0.00 |
| August | 46.57 | 25.93 | 20.64 | 57.69 | 10.69 | 306.00 | 0.00 | 0.00 |
| September | 32.93 | 16.97 | 15.96 | 36.95 | 15.58 | 273.67 | 0.00 | 0.00 |
| October | 23.45 | 11.82 | 11.63 | 21.53 | 23.10 | 285.17 | 0.00 | 0.00 |
| November | 14.95 | 6.98 | 7.97 | 9.88 | 31.88 | 172.50 | 0.00 | 0.00 |
| December | 11.05 | 4.75 | 6.30 | 5.08 | 43.92 | 230.33 | 0.00 | 0.00 |
| Annual Sum or Average | 30.99 | 15.58 | 15.41 | 31.63 | 25.45 | 2835.83 | 0.00 | 0.00 |
| Minimum of Months | 11.05 | 4.75 | 6.30 | 5.08 | 9.37 | 122.50 | 0.00 | 0.00 |
| Maximum of Months | 53.64 | 30.35 | 24.78 | 68.44 | 51.02 | 306.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.657907E+09 | 0.739804E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.839801E+09 | 0.491142E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.823806E+09 | 0.472701E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.704571E+09 | 0.321975E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.648675E+09 | 0.262520E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.689404E+09 | 0.178426E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.852193E+09 | 0.148478E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.956623E+09 | 0.169786E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.980745E+09 | 0.237809E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.973139E+09 | 0.357294E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.776285E+09 | 0.444194E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.644179E+09 | 0.631591E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.954733E+10 | 0.445572E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.644179E+09 | 0.148478E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.980745E+09 | 0.739804E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.135408E+09 | 55002115.31 | 80405737.39 | 68919331.87 | 0.551293E+09 |
| February | 0.207211E+09 | 0.101978E+09 | 0.105233E+09 | 0.162306E+09 | 0.357380E+09 |
| March | 0.294508E+09 | 0.108169E+09 | 0.186339E+09 | 0.246214E+09 | 0.319313E+09 |
| April | 0.371410E+09 | 0.164067E+09 | 0.207343E+09 | 0.382538E+09 | 0.209723E+09 |
| May | 0.474809E+09 | 0.216610E+09 | 0.258199E+09 | 0.533328E+09 | 0.168332E+09 |
| June | 0.499525E+09 | 0.229373E+09 | 0.270152E+09 | 0.613898E+09 | 0.113170E+09 |
| July | 0.529324E+09 | 0.267596E+09 | 0.261728E+09 | 0.700393E+09 | 97174330.83 |
| August | 0.448505E+09 | 0.219524E+09 | 0.228982E+09 | 0.574942E+09 | 0.109957E+09 |
| September | 0.349462E+09 | 0.176575E+09 | 0.172887E+09 | 0.410452E+09 | 0.158791E+09 |
| October | 0.258607E+09 | 0.128549E+09 | 0.130058E+09 | 0.251378E+09 | 0.246902E+09 |
| November | 0.176843E+09 | 87739504.81 | 89103908.10 | 0.140292E+09 | 0.326440E+09 |
| December | 0.122589E+09 | 51652699.56 | 70935977.75 | 66464170.19 | 0.468610E+09 |
| Annual Sum or Average | 0.386820E+10 | 0.180683E+10 | 0.206137E+10 | 0.415113E+10 | 0.312708E+10 |
| Minimum of Months | 0.122589E+09 | 51652699.56 | 70935977.75 | 66464170.19 | 97174330.83 |
| Maximum of Months | 0.529324E+09 | 0.267596E+09 | 0.270152E+09 | 0.700393E+09 | 0.551293E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.135408E+09 | 55002115.31 | 80405737.39 | 71050430.57 | 0.544281E+09 |
| February | 0.207211E+09 | 0.101978E+09 | 0.105233E+09 | 0.167437E+09 | 0.349931E+09 |
| March | 0.294508E+09 | 0.108169E+09 | 0.186339E+09 | 0.251878E+09 | 0.313178E+09 |
| April | 0.371410E+09 | 0.164067E+09 | 0.207343E+09 | 0.389267E+09 | 0.204354E+09 |
| May | 0.474809E+09 | 0.216610E+09 | 0.258199E+09 | 0.539330E+09 | 0.164404E+09 |
| June | 0.499525E+09 | 0.229373E+09 | 0.270152E+09 | 0.617976E+09 | 0.110637E+09 |
| July | 0.529324E+09 | 0.267596E+09 | 0.261728E+09 | 0.703429E+09 | 95596467.70 |
| August | 0.448505E+09 | 0.219524E+09 | 0.228982E+09 | 0.580105E+09 | 0.106622E+09 |
| September | 0.349462E+09 | 0.176575E+09 | 0.172887E+09 | 0.419366E+09 | 0.149465E+09 |
| October | 0.258607E+09 | 0.128549E+09 | 0.130058E+09 | 0.264086E+09 | 0.227868E+09 |
| November | 0.176843E+09 | 87739504.81 | 89103908.10 | 0.146520E+09 | 0.314404E+09 |
| December | 0.122589E+09 | 51652699.56 | 70935977.75 | 68823690.81 | 0.461472E+09 |
| Annual Sum or Average | 0.386820E+10 | 0.180683E+10 | 0.206137E+10 | 0.421927E+10 | 0.304221E+10 |
| Minimum of Months | 0.122589E+09 | 51652699.56 | 70935977.75 | 68823690.81 | 95596467.70 |
| Maximum of Months | 0.529324E+09 | 0.267596E+09 | 0.270152E+09 | 0.703429E+09 | 0.544281E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2564883.11 | 0.867186E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 24006240.37 | 0.566222E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 92087245.21 | 0.487560E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.159814E+09 | 0.310407E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.289449E+09 | 0.238867E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.411669E+09 | 0.151660E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.448911E+09 | 0.133966E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.331859E+09 | 0.154378E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.191370E+09 | 0.228669E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 81247792.24 | 0.354085E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 20441019.51 | 0.505749E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 2018582.32 | 0.741114E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.205544E+10 | 0.473986E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 2018582.32 | 0.133966E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.448911E+09 | 0.867186E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.676033E+09 | 0.663273E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.857838E+09 | 0.438517E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.839586E+09 | 0.428841E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.709836E+09 | 0.304757E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.645930E+09 | 0.257507E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.671368E+09 | 0.200097E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.821788E+09 | 0.184582E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.933268E+09 | 0.206163E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.961509E+09 | 0.270076E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.968671E+09 | 0.368976E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.781504E+09 | 0.426766E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.663508E+09 | 0.565070E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.953084E+10 | 0.431462E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.645930E+09 | 0.184582E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.968671E+09 | 0.663273E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149616E+09 | 69004258.54 | 80611465.20 | 85554812.95 | 0.473935E+09 |
| February | 0.210849E+09 | 0.104982E+09 | 0.105868E+09 | 0.170393E+09 | 0.310260E+09 |
| March | 0.312990E+09 | 0.129641E+09 | 0.183349E+09 | 0.278324E+09 | 0.277988E+09 |
| April | 0.386038E+09 | 0.191477E+09 | 0.194561E+09 | 0.401787E+09 | 0.190393E+09 |
| May | 0.440605E+09 | 0.196186E+09 | 0.244419E+09 | 0.483209E+09 | 0.159479E+09 |
| June | 0.551542E+09 | 0.283856E+09 | 0.267686E+09 | 0.665591E+09 | 0.116914E+09 |
| July | 0.598747E+09 | 0.338752E+09 | 0.259995E+09 | 0.765491E+09 | 0.110550E+09 |
| August | 0.519840E+09 | 0.289487E+09 | 0.230353E+09 | 0.647340E+09 | 0.124391E+09 |
| September | 0.355697E+09 | 0.183329E+09 | 0.172368E+09 | 0.400096E+09 | 0.169965E+09 |
| October | 0.261747E+09 | 0.131915E+09 | 0.129832E+09 | 0.247684E+09 | 0.244386E+09 |
| November | 0.161516E+09 | 75384451.24 | 86131821.02 | 0.115602E+09 | 0.302593E+09 |
| December | 0.123350E+09 | 53060374.77 | 70289849.52 | 67854412.85 | 0.404633E+09 |
| Annual Sum or Average | 0.407254E+10 | 0.204707E+10 | 0.202546E+10 | 0.432892E+10 | 0.288549E+10 |
| Minimum of Months | 0.123350E+09 | 53060374.77 | 70289849.52 | 67854412.85 | 0.110550E+09 |
| Maximum of Months | 0.598747E+09 | 0.338752E+09 | 0.267686E+09 | 0.765491E+09 | 0.473935E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149616E+09 | 69004258.54 | 80611465.20 | 80535810.01 | 0.521883E+09 |
| February | 0.210849E+09 | 0.104982E+09 | 0.105868E+09 | 0.165684E+09 | 0.339344E+09 |
| March | 0.312990E+09 | 0.129641E+09 | 0.183349E+09 | 0.272184E+09 | 0.299543E+09 |
| April | 0.386038E+09 | 0.191477E+09 | 0.194561E+09 | 0.402826E+09 | 0.194775E+09 |
| May | 0.440605E+09 | 0.196186E+09 | 0.244419E+09 | 0.489347E+09 | 0.156775E+09 |
| June | 0.551542E+09 | 0.283856E+09 | 0.267686E+09 | 0.681097E+09 | 0.101701E+09 |
| July | 0.598747E+09 | 0.338752E+09 | 0.259995E+09 | 0.789422E+09 | 87522462.44 |
| August | 0.519840E+09 | 0.289487E+09 | 0.230353E+09 | 0.668364E+09 | 99818920.23 |
| September | 0.355697E+09 | 0.183329E+09 | 0.172368E+09 | 0.421131E+09 | 0.140710E+09 |
| October | 0.261747E+09 | 0.131915E+09 | 0.129832E+09 | 0.261541E+09 | 0.217058E+09 |
| November | 0.161516E+09 | 75384451.24 | 86131821.02 | 0.118414E+09 | 0.301919E+09 |
| December | 0.123350E+09 | 53060374.77 | 70289849.52 | 63090211.38 | 0.446269E+09 |
| Annual Sum or Average | 0.407254E+10 | 0.204707E+10 | 0.202546E+10 | 0.441364E+10 | 0.290732E+10 |
| Minimum of Months | 0.123350E+09 | 53060374.77 | 70289849.52 | 63090211.38 | 87522462.44 |
| Maximum of Months | 0.598747E+09 | 0.338752E+09 | 0.267686E+09 | 0.789422E+09 | 0.521883E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2495456.90 | 0.867654E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 23620636.09 | 0.566057E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 91263267.82 | 0.487400E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.158746E+09 | 0.309916E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.288739E+09 | 0.237254E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.408378E+09 | 0.151063E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.446295E+09 | 0.133430E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.329026E+09 | 0.154616E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.189647E+09 | 0.228412E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 80144995.12 | 0.353430E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 20308362.08 | 0.505312E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1987789.18 | 0.741195E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.204065E+10 | 0.473574E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1987789.18 | 0.133430E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.446295E+09 | 0.867654E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2335659.65 | 0.880594E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 23046104.12 | 0.575102E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 89822033.10 | 0.495632E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.158004E+09 | 0.315900E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.288558E+09 | 0.242068E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.409584E+09 | 0.154706E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.450920E+09 | 0.133708E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.332661E+09 | 0.155806E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.190980E+09 | 0.232484E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 79376625.63 | 0.360737E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 19784885.74 | 0.513266E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1812010.65 | 0.752282E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.204688E+10 | 0.481229E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1812010.65 | 0.133708E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.450920E+09 | 0.880594E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2333537.22 | 0.880618E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 23030200.16 | 0.575098E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 89788523.51 | 0.495630E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.157949E+09 | 0.315889E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.288529E+09 | 0.241977E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.409387E+09 | 0.154723E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.450811E+09 | 0.133712E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.332496E+09 | 0.155892E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.190861E+09 | 0.232541E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 79309301.19 | 0.360755E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 19777972.03 | 0.513241E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1810893.78 | 0.752283E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.204608E+10 | 0.481236E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1810893.78 | 0.133712E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.450811E+09 | 0.880618E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.653992E+09 | 0.752280E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.835408E+09 | 0.500389E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.819041E+09 | 0.482411E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.700462E+09 | 0.329735E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.646440E+09 | 0.267154E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.687437E+09 | 0.182693E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.854141E+09 | 0.148488E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.957369E+09 | 0.171176E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.978604E+09 | 0.243634E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.968058E+09 | 0.368102E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.770180E+09 | 0.456240E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.640407E+09 | 0.642126E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.951154E+10 | 0.454443E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.640407E+09 | 0.148488E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.978604E+09 | 0.752280E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.654953E+09 | 0.749209E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.836579E+09 | 0.497919E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.820028E+09 | 0.480392E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.700835E+09 | 0.328896E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.646042E+09 | 0.267154E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.685849E+09 | 0.184215E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.852580E+09 | 0.149944E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.955966E+09 | 0.172726E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.977194E+09 | 0.245663E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.967417E+09 | 0.369070E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.770160E+09 | 0.455774E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.641459E+09 | 0.639227E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.950906E+10 | 0.454019E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.641459E+09 | 0.149944E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.977194E+09 | 0.749209E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.647119E+09 | 0.763100E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.824389E+09 | 0.512931E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.804087E+09 | 0.500355E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.678311E+09 | 0.358862E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.622483E+09 | 0.292889E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.673614E+09 | 0.193406E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.845651E+09 | 0.152333E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.950393E+09 | 0.173635E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.973894E+09 | 0.242434E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.964946E+09 | 0.364935E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.766690E+09 | 0.456991E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.634765E+09 | 0.648445E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.938634E+10 | 0.466032E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.622483E+09 | 0.152333E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.973894E+09 | 0.763100E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.135408E+09 | 55002115.31 | 80405737.39 | 66129873.74 | 0.570804E+09 |
| February | 0.207211E+09 | 0.101978E+09 | 0.105233E+09 | 0.155629E+09 | 0.374372E+09 |
| March | 0.294508E+09 | 0.108169E+09 | 0.186339E+09 | 0.234440E+09 | 0.338537E+09 |
| April | 0.371410E+09 | 0.164067E+09 | 0.207343E+09 | 0.364517E+09 | 0.233459E+09 |
| May | 0.474809E+09 | 0.216610E+09 | 0.258199E+09 | 0.514471E+09 | 0.187096E+09 |
| June | 0.499525E+09 | 0.229373E+09 | 0.270152E+09 | 0.602580E+09 | 0.122395E+09 |
| July | 0.529324E+09 | 0.267596E+09 | 0.261728E+09 | 0.695989E+09 | 99801617.86 |
| August | 0.448505E+09 | 0.219524E+09 | 0.228982E+09 | 0.571110E+09 | 0.112507E+09 |
| September | 0.349462E+09 | 0.176575E+09 | 0.172887E+09 | 0.406794E+09 | 0.162164E+09 |
| October | 0.258607E+09 | 0.128549E+09 | 0.130058E+09 | 0.247416E+09 | 0.252544E+09 |
| November | 0.176843E+09 | 87739504.81 | 89103908.10 | 0.136523E+09 | 0.336841E+09 |
| December | 0.122589E+09 | 51652699.56 | 70935977.75 | 63904132.68 | 0.482768E+09 |
| Annual Sum or Average | 0.386820E+10 | 0.180683E+10 | 0.206137E+10 | 0.405950E+10 | 0.327329E+10 |
| Minimum of Months | 0.122589E+09 | 51652699.56 | 70935977.75 | 63904132.68 | 99801617.86 |
| Maximum of Months | 0.529324E+09 | 0.267596E+09 | 0.270152E+09 | 0.695989E+09 | 0.570804E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.135408E+09 | 55002115.31 | 80405737.39 | 68772992.32 | 0.563234E+09 |
| February | 0.207211E+09 | 0.101978E+09 | 0.105233E+09 | 0.162193E+09 | 0.365193E+09 |
| March | 0.294508E+09 | 0.108169E+09 | 0.186339E+09 | 0.242721E+09 | 0.330103E+09 |
| April | 0.371410E+09 | 0.164067E+09 | 0.207343E+09 | 0.373721E+09 | 0.224646E+09 |
| May | 0.474809E+09 | 0.216610E+09 | 0.258199E+09 | 0.519795E+09 | 0.183739E+09 |
| June | 0.499525E+09 | 0.229373E+09 | 0.270152E+09 | 0.604554E+09 | 0.121849E+09 |
| July | 0.529324E+09 | 0.267596E+09 | 0.261728E+09 | 0.698444E+09 | 98990038.44 |
| August | 0.448505E+09 | 0.219524E+09 | 0.228982E+09 | 0.575187E+09 | 0.110720E+09 |
| September | 0.349462E+09 | 0.176575E+09 | 0.172887E+09 | 0.414816E+09 | 0.154970E+09 |
| October | 0.258607E+09 | 0.128549E+09 | 0.130058E+09 | 0.259463E+09 | 0.236073E+09 |
| November | 0.176843E+09 | 87739504.81 | 89103908.10 | 0.143802E+09 | 0.323632E+09 |
| December | 0.122589E+09 | 51652699.56 | 70935977.75 | 66639372.23 | 0.475647E+09 |
| Annual Sum or Average | 0.386820E+10 | 0.180683E+10 | 0.206137E+10 | 0.413011E+10 | 0.318880E+10 |
| Minimum of Months | 0.122589E+09 | 51652699.56 | 70935977.75 | 66639372.23 | 98990038.44 |
| Maximum of Months | 0.529324E+09 | 0.267596E+09 | 0.270152E+09 | 0.698444E+09 | 0.563234E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 1971499.80 | 0.896016E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 20146680.22 | 0.591299E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 81967996.66 | 0.514132E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.139913E+09 | 0.342786E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.260563E+09 | 0.266756E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.390831E+09 | 0.166281E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.442073E+09 | 0.138250E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.325526E+09 | 0.160181E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.186462E+09 | 0.236876E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 76556054.86 | 0.366666E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 18918890.13 | 0.520104E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1548581.60 | 0.762976E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.194648E+10 | 0.496232E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1548581.60 | 0.138250E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.442073E+09 | 0.896016E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.646419E+09 | 0.763143E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.823173E+09 | 0.512312E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.801844E+09 | 0.499877E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.675390E+09 | 0.358519E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.620421E+09 | 0.290931E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.671226E+09 | 0.192582E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.843631E+09 | 0.151609E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.948358E+09 | 0.173250E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.972021E+09 | 0.241956E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.963095E+09 | 0.364207E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.765835E+09 | 0.455995E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.634315E+09 | 0.648128E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.936573E+10 | 0.465251E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.620421E+09 | 0.151609E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.972021E+09 | 0.763143E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149616E+09 | 69004258.54 | 80611465.20 | 76173556.44 | 0.547223E+09 |
| February | 0.210849E+09 | 0.104982E+09 | 0.105868E+09 | 0.155025E+09 | 0.364116E+09 |
| March | 0.312990E+09 | 0.129641E+09 | 0.183349E+09 | 0.255164E+09 | 0.324118E+09 |
| April | 0.386038E+09 | 0.191477E+09 | 0.194561E+09 | 0.377391E+09 | 0.223375E+09 |
| May | 0.440605E+09 | 0.196186E+09 | 0.244419E+09 | 0.464305E+09 | 0.178938E+09 |
| June | 0.551542E+09 | 0.283856E+09 | 0.267686E+09 | 0.665814E+09 | 0.112270E+09 |
| July | 0.598747E+09 | 0.338752E+09 | 0.259995E+09 | 0.781857E+09 | 90985276.78 |
| August | 0.519840E+09 | 0.289487E+09 | 0.230353E+09 | 0.659418E+09 | 0.104743E+09 |
| September | 0.355697E+09 | 0.183329E+09 | 0.172368E+09 | 0.408346E+09 | 0.152213E+09 |
| October | 0.261747E+09 | 0.131915E+09 | 0.129832E+09 | 0.244922E+09 | 0.240927E+09 |
| November | 0.161516E+09 | 75384451.24 | 86131821.02 | 0.110649E+09 | 0.325454E+09 |
| December | 0.123350E+09 | 53060374.77 | 70289849.52 | 59468261.87 | 0.467522E+09 |
| Annual Sum or Average | 0.407254E+10 | 0.204707E+10 | 0.202546E+10 | 0.425853E+10 | 0.313188E+10 |
| Minimum of Months | 0.123350E+09 | 53060374.77 | 70289849.52 | 59468261.87 | 90985276.78 |
| Maximum of Months | 0.598747E+09 | 0.338752E+09 | 0.267686E+09 | 0.781857E+09 | 0.547223E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149616E+09 | 69004258.54 | 80611465.20 | 77941523.60 | 0.538981E+09 |
| February | 0.210849E+09 | 0.104982E+09 | 0.105868E+09 | 0.160503E+09 | 0.353925E+09 |
| March | 0.312990E+09 | 0.129641E+09 | 0.183349E+09 | 0.263042E+09 | 0.314862E+09 |
| April | 0.386038E+09 | 0.191477E+09 | 0.194561E+09 | 0.386373E+09 | 0.214626E+09 |
| May | 0.440605E+09 | 0.196186E+09 | 0.244419E+09 | 0.469354E+09 | 0.175451E+09 |
| June | 0.551542E+09 | 0.283856E+09 | 0.267686E+09 | 0.667628E+09 | 0.111683E+09 |
| July | 0.598747E+09 | 0.338752E+09 | 0.259995E+09 | 0.784296E+09 | 90124845.93 |
| August | 0.519840E+09 | 0.289487E+09 | 0.230353E+09 | 0.663358E+09 | 0.103052E+09 |
| September | 0.355697E+09 | 0.183329E+09 | 0.172368E+09 | 0.416241E+09 | 0.145470E+09 |
| October | 0.261747E+09 | 0.131915E+09 | 0.129832E+09 | 0.256775E+09 | 0.224444E+09 |
| November | 0.161516E+09 | 75384451.24 | 86131821.02 | 0.115882E+09 | 0.310240E+09 |
| December | 0.123350E+09 | 53060374.77 | 70289849.52 | 61014996.84 | 0.459473E+09 |
| Annual Sum or Average | 0.407254E+10 | 0.204707E+10 | 0.202546E+10 | 0.432241E+10 | 0.304233E+10 |
| Minimum of Months | 0.123350E+09 | 53060374.77 | 70289849.52 | 61014996.84 | 90124845.93 |
| Maximum of Months | 0.598747E+09 | 0.338752E+09 | 0.267686E+09 | 0.784296E+09 | 0.538981E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 1896082.11 | 0.896533E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 19642375.99 | 0.590923E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 80980200.15 | 0.513594E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.137098E+09 | 0.342667E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.258630E+09 | 0.265118E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.388124E+09 | 0.165441E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.439754E+09 | 0.137347E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.323132E+09 | 0.159876E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.184337E+09 | 0.236606E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 75112741.84 | 0.365650E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 18787098.45 | 0.519430E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1515949.76 | 0.763066E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.192901E+10 | 0.495625E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1515949.76 | 0.137347E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.439754E+09 | 0.896533E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 1802995.65 | 0.907880E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 19569860.02 | 0.598263E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 80979205.61 | 0.519471E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.139820E+09 | 0.346449E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.262025E+09 | 0.268400E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.392725E+09 | 0.166818E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.446108E+09 | 0.136840E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.328146E+09 | 0.160266E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.186440E+09 | 0.240813E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 73958100.52 | 0.375672E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 18184198.85 | 0.528117E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1386625.04 | 0.773676E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.195115E+10 | 0.502266E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1386625.04 | 0.136840E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.446108E+09 | 0.907880E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 1800312.55 | 0.907913E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 19541784.08 | 0.598249E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 80925411.92 | 0.519451E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.139587E+09 | 0.346621E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.261881E+09 | 0.268342E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.392620E+09 | 0.166794E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.446033E+09 | 0.136815E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.328041E+09 | 0.160282E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.186291E+09 | 0.240888E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 73870298.34 | 0.375672E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 18177863.37 | 0.528062E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1385381.93 | 0.773677E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.195015E+10 | 0.502277E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1385381.93 | 0.136815E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.446033E+09 | 0.907913E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.643138E+09 | 0.775480E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.820343E+09 | 0.521809E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.799773E+09 | 0.510078E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.675198E+09 | 0.367404E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.622553E+09 | 0.295173E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.675505E+09 | 0.194022E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.849418E+09 | 0.150985E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.952689E+09 | 0.173596E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.972676E+09 | 0.247532E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.960060E+09 | 0.376122E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.760072E+09 | 0.470817E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.630648E+09 | 0.659054E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.936207E+10 | 0.474207E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.622553E+09 | 0.150985E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.972676E+09 | 0.775480E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.643097E+09 | 0.775517E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.820280E+09 | 0.521799E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.799615E+09 | 0.510154E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.675030E+09 | 0.367489E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.622449E+09 | 0.295067E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.675417E+09 | 0.193987E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.849348E+09 | 0.150959E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.952611E+09 | 0.173594E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.972588E+09 | 0.247549E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.959985E+09 | 0.376109E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.760028E+09 | 0.470770E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.630626E+09 | 0.659041E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.936108E+10 | 0.474203E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.622449E+09 | 0.150959E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.972588E+09 | 0.775517E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.647786E+09 | 0.742477E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.823219E+09 | 0.496869E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.801568E+09 | 0.482787E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.678343E+09 | 0.338761E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.621087E+09 | 0.277396E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.672926E+09 | 0.178817E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.839320E+09 | 0.144157E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.945686E+09 | 0.162379E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.972981E+09 | 0.224719E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.970253E+09 | 0.335925E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.769310E+09 | 0.436641E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.635912E+09 | 0.629270E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.937839E+10 | 0.445020E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.621087E+09 | 0.144157E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.972981E+09 | 0.742477E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.135408E+09 | 55002115.31 | 80405737.39 | 65411945.66 | 0.555583E+09 |
| February | 0.207211E+09 | 0.101978E+09 | 0.105233E+09 | 0.153821E+09 | 0.362081E+09 |
| March | 0.294508E+09 | 0.108169E+09 | 0.186339E+09 | 0.231944E+09 | 0.325696E+09 |
| April | 0.371410E+09 | 0.164067E+09 | 0.207343E+09 | 0.363994E+09 | 0.219488E+09 |
| May | 0.474809E+09 | 0.216610E+09 | 0.258199E+09 | 0.512838E+09 | 0.176117E+09 |
| June | 0.499525E+09 | 0.229373E+09 | 0.270152E+09 | 0.601912E+09 | 0.112486E+09 |
| July | 0.529324E+09 | 0.267596E+09 | 0.261728E+09 | 0.691691E+09 | 94173352.81 |
| August | 0.448505E+09 | 0.219524E+09 | 0.228982E+09 | 0.567990E+09 | 0.104756E+09 |
| September | 0.349462E+09 | 0.176575E+09 | 0.172887E+09 | 0.405484E+09 | 0.149248E+09 |
| October | 0.258607E+09 | 0.128549E+09 | 0.130058E+09 | 0.249211E+09 | 0.231050E+09 |
| November | 0.176843E+09 | 87739504.81 | 89103908.10 | 0.136375E+09 | 0.321104E+09 |
| December | 0.122589E+09 | 51652699.56 | 70935977.75 | 63466667.17 | 0.468308E+09 |
| Annual Sum or Average | 0.386820E+10 | 0.180683E+10 | 0.206137E+10 | 0.404414E+10 | 0.312009E+10 |
| Minimum of Months | 0.122589E+09 | 51652699.56 | 70935977.75 | 63466667.17 | 94173352.81 |
| Maximum of Months | 0.529324E+09 | 0.267596E+09 | 0.270152E+09 | 0.691691E+09 | 0.555583E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.135408E+09 | 55002115.31 | 80405737.39 | 69307537.97 | 0.548867E+09 |
| February | 0.207211E+09 | 0.101978E+09 | 0.105233E+09 | 0.162700E+09 | 0.354673E+09 |
| March | 0.294508E+09 | 0.108169E+09 | 0.186339E+09 | 0.242782E+09 | 0.319683E+09 |
| April | 0.371410E+09 | 0.164067E+09 | 0.207343E+09 | 0.373599E+09 | 0.214930E+09 |
| May | 0.474809E+09 | 0.216610E+09 | 0.258199E+09 | 0.519069E+09 | 0.174345E+09 |
| June | 0.499525E+09 | 0.229373E+09 | 0.270152E+09 | 0.604773E+09 | 0.112269E+09 |
| July | 0.529324E+09 | 0.267596E+09 | 0.261728E+09 | 0.695082E+09 | 93628700.93 |
| August | 0.448505E+09 | 0.219524E+09 | 0.228982E+09 | 0.574070E+09 | 0.103106E+09 |
| September | 0.349462E+09 | 0.176575E+09 | 0.172887E+09 | 0.415533E+09 | 0.144522E+09 |
| October | 0.258607E+09 | 0.128549E+09 | 0.130058E+09 | 0.262632E+09 | 0.221391E+09 |
| November | 0.176843E+09 | 87739504.81 | 89103908.10 | 0.144936E+09 | 0.312086E+09 |
| December | 0.122589E+09 | 51652699.56 | 70935977.75 | 67403625.80 | 0.461997E+09 |
| Annual Sum or Average | 0.386820E+10 | 0.180683E+10 | 0.206137E+10 | 0.413189E+10 | 0.306150E+10 |
| Minimum of Months | 0.122589E+09 | 51652699.56 | 70935977.75 | 67403625.80 | 93628700.93 |
| Maximum of Months | 0.529324E+09 | 0.267596E+09 | 0.270152E+09 | 0.695082E+09 | 0.548867E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2190298.36 | 0.873554E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 20943483.68 | 0.575382E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 83034418.15 | 0.498775E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.140431E+09 | 0.328549E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.260990E+09 | 0.253800E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.394564E+09 | 0.154976E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.439351E+09 | 0.132271E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.325338E+09 | 0.150149E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.188465E+09 | 0.221750E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 81612443.30 | 0.344823E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 20046686.06 | 0.501915E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1815635.17 | 0.741361E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.195878E+10 | 0.477730E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1815635.17 | 0.132271E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.439351E+09 | 0.873554E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.646681E+09 | 0.742234E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.821295E+09 | 0.495631E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.798278E+09 | 0.481442E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.673730E+09 | 0.336990E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.616817E+09 | 0.274219E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.667372E+09 | 0.177023E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.835014E+09 | 0.142698E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.941367E+09 | 0.161247E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.969412E+09 | 0.223262E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.966915E+09 | 0.334383E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.768167E+09 | 0.434972E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.635156E+09 | 0.628735E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.934021E+10 | 0.443284E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.616817E+09 | 0.142698E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.969412E+09 | 0.742234E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149616E+09 | 69004258.54 | 80611465.20 | 77074046.16 | 0.532897E+09 |
| February | 0.210849E+09 | 0.104982E+09 | 0.105868E+09 | 0.155245E+09 | 0.353633E+09 |
| March | 0.312990E+09 | 0.129641E+09 | 0.183349E+09 | 0.254517E+09 | 0.312498E+09 |
| April | 0.386038E+09 | 0.191477E+09 | 0.194561E+09 | 0.377788E+09 | 0.210258E+09 |
| May | 0.440605E+09 | 0.196186E+09 | 0.244419E+09 | 0.463432E+09 | 0.169044E+09 |
| June | 0.551542E+09 | 0.283856E+09 | 0.267686E+09 | 0.665736E+09 | 0.104353E+09 |
| July | 0.598747E+09 | 0.338752E+09 | 0.259995E+09 | 0.777488E+09 | 86406239.34 |
| August | 0.519840E+09 | 0.289487E+09 | 0.230353E+09 | 0.656439E+09 | 98342046.81 |
| September | 0.355697E+09 | 0.183329E+09 | 0.172368E+09 | 0.408420E+09 | 0.141113E+09 |
| October | 0.261747E+09 | 0.131915E+09 | 0.129832E+09 | 0.248815E+09 | 0.222176E+09 |
| November | 0.161516E+09 | 75384451.24 | 86131821.02 | 0.113078E+09 | 0.311705E+09 |
| December | 0.123350E+09 | 53060374.77 | 70289849.52 | 60546771.35 | 0.454104E+09 |
| Annual Sum or Average | 0.407254E+10 | 0.204707E+10 | 0.202546E+10 | 0.425858E+10 | 0.299653E+10 |
| Minimum of Months | 0.123350E+09 | 53060374.77 | 70289849.52 | 60546771.35 | 86406239.34 |
| Maximum of Months | 0.598747E+09 | 0.338752E+09 | 0.267686E+09 | 0.777488E+09 | 0.532897E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149616E+09 | 69004258.54 | 80611465.20 | 79287423.84 | 0.524732E+09 |
| February | 0.210849E+09 | 0.104982E+09 | 0.105868E+09 | 0.161856E+09 | 0.343940E+09 |
| March | 0.312990E+09 | 0.129641E+09 | 0.183349E+09 | 0.264329E+09 | 0.304934E+09 |
| April | 0.386038E+09 | 0.191477E+09 | 0.194561E+09 | 0.386711E+09 | 0.205088E+09 |
| May | 0.440605E+09 | 0.196186E+09 | 0.244419E+09 | 0.469136E+09 | 0.166733E+09 |
| June | 0.551542E+09 | 0.283856E+09 | 0.267686E+09 | 0.668193E+09 | 0.104030E+09 |
| July | 0.598747E+09 | 0.338752E+09 | 0.259995E+09 | 0.780829E+09 | 85687258.34 |
| August | 0.519840E+09 | 0.289487E+09 | 0.230353E+09 | 0.662091E+09 | 96679106.49 |
| September | 0.355697E+09 | 0.183329E+09 | 0.172368E+09 | 0.417846E+09 | 0.135944E+09 |
| October | 0.261747E+09 | 0.131915E+09 | 0.129832E+09 | 0.261240E+09 | 0.210496E+09 |
| November | 0.161516E+09 | 75384451.24 | 86131821.02 | 0.117913E+09 | 0.299205E+09 |
| December | 0.123350E+09 | 53060374.77 | 70289849.52 | 62462394.81 | 0.446108E+09 |
| Annual Sum or Average | 0.407254E+10 | 0.204707E+10 | 0.202546E+10 | 0.433189E+10 | 0.292358E+10 |
| Minimum of Months | 0.123350E+09 | 53060374.77 | 70289849.52 | 62462394.81 | 85687258.34 |
| Maximum of Months | 0.598747E+09 | 0.338752E+09 | 0.267686E+09 | 0.780829E+09 | 0.524732E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2059167.31 | 0.874061E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 20102430.41 | 0.574518E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 81374226.22 | 0.497537E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.136002E+09 | 0.326879E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.257193E+09 | 0.251112E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.388594E+09 | 0.153331E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.434659E+09 | 0.130456E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.320236E+09 | 0.148944E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.184700E+09 | 0.220026E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 79462629.34 | 0.342250E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 19758425.25 | 0.501096E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1747757.12 | 0.741467E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.192589E+10 | 0.476168E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1747757.12 | 0.130456E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.434659E+09 | 0.874061E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2024236.89 | 0.886766E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 20596859.64 | 0.582809E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 82538942.22 | 0.504735E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.141643E+09 | 0.331889E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.263213E+09 | 0.256762E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.396510E+09 | 0.157027E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.443348E+09 | 0.132547E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.328155E+09 | 0.151918E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.189865E+09 | 0.224589E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 81345582.00 | 0.348941E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 19648693.84 | 0.509272E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1651682.08 | 0.752942E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.197054E+10 | 0.484020E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1651682.08 | 0.132547E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.443348E+09 | 0.886766E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 98341482.54 | 0.00 | 98341482.54 | 2017735.08 | 0.886789E+09 |
| February | 0.125415E+09 | 0.00 | 0.125415E+09 | 20533789.06 | 0.582748E+09 |
| March | 0.225586E+09 | 11702.76 | 0.225574E+09 | 82413085.66 | 0.504640E+09 |
| April | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.141197E+09 | 0.331823E+09 |
| May | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.262822E+09 | 0.256567E+09 |
| June | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.396059E+09 | 0.156946E+09 |
| July | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.443093E+09 | 0.132442E+09 |
| August | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.327817E+09 | 0.151861E+09 |
| September | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.189541E+09 | 0.224499E+09 |
| October | 0.157280E+09 | 0.00 | 0.157280E+09 | 81170132.84 | 0.348716E+09 |
| November | 0.103471E+09 | 0.00 | 0.103471E+09 | 19625578.09 | 0.509206E+09 |
| December | 82464892.92 | 0.00 | 82464892.92 | 1647895.75 | 0.752943E+09 |
| Annual Sum or Average | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.196794E+10 | 0.483918E+10 |
| Minimum of Months | 82464892.92 | 0.00 | 82464892.92 | 1647895.75 | 0.132442E+09 |
| Maximum of Months | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.443093E+09 | 0.886789E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.643958E+09 | 0.754847E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.819827E+09 | 0.505439E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.798617E+09 | 0.491040E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.677271E+09 | 0.344496E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.621396E+09 | 0.280941E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.674889E+09 | 0.181210E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.843379E+09 | 0.144935E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.948198E+09 | 0.164556E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.972803E+09 | 0.229468E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.967022E+09 | 0.344523E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.765350E+09 | 0.445807E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.631885E+09 | 0.639988E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.936459E+10 | 0.452725E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.621396E+09 | 0.144935E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.972803E+09 | 0.754847E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.643890E+09 | 0.754838E+09 |
| February | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.819688E+09 | 0.505356E+09 |
| March | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.798370E+09 | 0.490964E+09 |
| April | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.676926E+09 | 0.344394E+09 |
| May | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.621046E+09 | 0.280702E+09 |
| June | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.674511E+09 | 0.181081E+09 |
| July | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.843128E+09 | 0.144820E+09 |
| August | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.947944E+09 | 0.164477E+09 |
| September | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.972567E+09 | 0.229384E+09 |
| October | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.966787E+09 | 0.344440E+09 |
| November | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.765249E+09 | 0.445659E+09 |
| December | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.631825E+09 | 0.639952E+09 |
| Annual Sum or Average | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.936193E+10 | 0.452607E+10 |
| Minimum of Months | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.621046E+09 | 0.144820E+09 |
| Maximum of Months | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.972567E+09 | 0.754838E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 35900901.91 | 16557852.71 | 19343049.19 | 18600773.22 | 0.128368E+09 |
| February | 50594177.67 | 25190745.84 | 25403431.84 | 37638907.19 | 86277184.64 |
| March | 75103271.22 | 31107985.90 | 43995285.32 | 61576908.95 | 77495322.86 |
| April | 92631337.60 | 45945628.31 | 46685709.29 | 90844290.70 | 53883957.28 |
| May | 0.105725E+09 | 47075606.95 | 58649367.00 | 0.110191E+09 | 44513473.59 |
| June | 0.132345E+09 | 68112378.76 | 64232290.29 | 0.157212E+09 | 28757971.62 |
| July | 0.143672E+09 | 81284901.31 | 62386829.75 | 0.183518E+09 | 24259594.28 |
| August | 0.124738E+09 | 69463602.79 | 55274191.20 | 0.155257E+09 | 27249193.05 |
| September | 85350940.93 | 43990470.30 | 41360470.64 | 97316871.06 | 37460213.17 |
| October | 62807330.29 | 31653582.62 | 31153747.67 | 60291452.67 | 56426525.98 |
| November | 38756486.96 | 18088805.92 | 20667681.04 | 27133601.12 | 76593571.92 |
| December | 29598388.40 | 12732052.90 | 16866335.50 | 14507202.46 | 0.110135E+09 |
| Annual Sum or Average | 0.977222E+09 | 0.491204E+09 | 0.486018E+09 | 0.101409E+10 | 0.751421E+09 |
| Minimum of Months | 29598388.40 | 12732052.90 | 16866335.50 | 14507202.46 | 24259594.28 |
| Maximum of Months | 0.143672E+09 | 81284901.31 | 64232290.29 | 0.183518E+09 | 0.128368E+09 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.106922E+09 | 49313406.02 | 57608414.28 | 61098142.86 | 0.338014E+09 |
| February | 0.150682E+09 | 75024310.16 | 75657741.99 | 0.121206E+09 | 0.226180E+09 |
| March | 0.223676E+09 | 92647323.64 | 0.131029E+09 | 0.197700E+09 | 0.205621E+09 |
| April | 0.275879E+09 | 0.136838E+09 | 0.139042E+09 | 0.286490E+09 | 0.141430E+09 |
| May | 0.314875E+09 | 0.140203E+09 | 0.174672E+09 | 0.345515E+09 | 0.117167E+09 |
| June | 0.394155E+09 | 0.202856E+09 | 0.191300E+09 | 0.475368E+09 | 81944704.23 |
| July | 0.427890E+09 | 0.242087E+09 | 0.185804E+09 | 0.547657E+09 | 73689528.17 |
| August | 0.371500E+09 | 0.206880E+09 | 0.164620E+09 | 0.463825E+09 | 82677528.74 |
| September | 0.254196E+09 | 0.131015E+09 | 0.123182E+09 | 0.291486E+09 | 0.112395E+09 |
| October | 0.187056E+09 | 94272246.45 | 92783613.59 | 0.181531E+09 | 0.165200E+09 |
| November | 0.115426E+09 | 53872965.67 | 61553497.58 | 84488352.38 | 0.212440E+09 |
| December | 88151366.62 | 37919222.09 | 50232144.53 | 47421756.60 | 0.294282E+09 |
| Annual Sum or Average | 0.291041E+10 | 0.146293E+10 | 0.144748E+10 | 0.310379E+10 | 0.205104E+10 |
| Minimum of Months | 88151366.62 | 37919222.09 | 50232144.53 | 47421756.60 | 73689528.17 |
| Maximum of Months | 0.427890E+09 | 0.242087E+09 | 0.191300E+09 | 0.547657E+09 | 0.338014E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 35900901.91 | 16557852.71 | 19343049.19 | 17661934.31 | 0.136664E+09 |
| February | 50594177.67 | 25190745.84 | 25403431.84 | 36388828.17 | 91692570.47 |
| March | 75103271.22 | 31107985.90 | 43995285.32 | 59742844.55 | 82538553.62 |
| April | 92631337.60 | 45945628.31 | 46685709.29 | 89023237.51 | 57954578.71 |
| May | 0.105725E+09 | 47075606.95 | 58649367.00 | 0.108650E+09 | 47207912.14 |
| June | 0.132345E+09 | 68112378.76 | 64232290.29 | 0.155631E+09 | 30454850.85 |
| July | 0.143672E+09 | 81284901.31 | 62386829.75 | 0.183310E+09 | 25084892.77 |
| August | 0.124738E+09 | 69463602.79 | 55274191.20 | 0.154526E+09 | 28634728.90 |
| September | 85350940.93 | 43990470.30 | 41360470.64 | 95773293.44 | 40377429.40 |
| October | 62807330.29 | 31653582.62 | 31153747.67 | 57657940.68 | 61861781.53 |
| November | 38756486.96 | 18088805.92 | 20667681.04 | 25599976.79 | 82626392.37 |
| December | 29598388.40 | 12732052.90 | 16866335.50 | 13604724.39 | 0.117646E+09 |
| Annual Sum or Average | 0.977222E+09 | 0.491204E+09 | 0.486018E+09 | 0.997571E+09 | 0.802744E+09 |
| Minimum of Months | 29598388.40 | 12732052.90 | 16866335.50 | 13604724.39 | 25084892.77 |
| Maximum of Months | 0.143672E+09 | 81284901.31 | 64232290.29 | 0.183310E+09 | 0.136664E+09 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 254.28 | 464.95 | 308.91 | 204.87 | 104.05 | 0.00 | 0.00 |
| February | 403.48 | 339.99 | 414.38 | 278.38 | 135.99 | 0.00 | 0.00 |
| March | 395.68 | 291.89 | 400.21 | 201.47 | 198.74 | 0.00 | 0.00 |
| April | 416.86 | 202.58 | 385.57 | 182.01 | 203.55 | 0.00 | 0.00 |
| May | 439.03 | 158.59 | 389.01 | 152.08 | 236.93 | 0.00 | 0.00 |
| June | 501.00 | 110.68 | 402.04 | 149.73 | 252.31 | 0.00 | 0.00 |
| July | 579.38 | 91.43 | 424.21 | 184.36 | 239.86 | 0.00 | 0.00 |
| August | 571.12 | 103.74 | 430.43 | 212.13 | 218.30 | 0.00 | 0.00 |
| September | 535.19 | 151.47 | 434.54 | 252.77 | 181.77 | 0.00 | 0.00 |
| October | 453.04 | 221.44 | 410.17 | 265.80 | 144.37 | 0.00 | 0.00 |
| November | 343.32 | 287.02 | 349.85 | 237.49 | 112.36 | 0.00 | 0.00 |
| December | 250.62 | 396.07 | 291.48 | 196.68 | 94.81 | 0.00 | 0.00 |
| Annual Sum or Average | 428.57 | 234.64 | 386.44 | 209.30 | 177.14 | 0.00 | 0.00 |
| Minimum of Months | 250.62 | 91.43 | 291.48 | 149.73 | 94.81 | 0.00 | 0.00 |
| Maximum of Months | 579.38 | 464.95 | 434.54 | 278.38 | 252.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 17.17 | 516.67 | 87.27 | 20.54 | 66.74 | 0.00 | 0.00 |
| February | 70.34 | 369.90 | 137.49 | 42.15 | 95.34 | 0.00 | 0.00 |
| March | 125.09 | 295.63 | 194.18 | 40.39 | 153.79 | 0.00 | 0.00 |
| April | 210.47 | 197.23 | 239.61 | 64.03 | 175.58 | 0.00 | 0.00 |
| May | 307.76 | 148.89 | 303.28 | 88.25 | 215.04 | 0.00 | 0.00 |
| June | 394.44 | 98.39 | 339.38 | 105.24 | 234.13 | 0.00 | 0.00 |
| July | 427.87 | 83.35 | 331.59 | 112.29 | 219.30 | 0.00 | 0.00 |
| August | 339.45 | 96.41 | 276.06 | 85.88 | 190.18 | 0.00 | 0.00 |
| September | 234.60 | 144.87 | 215.41 | 68.19 | 147.21 | 0.00 | 0.00 |
| October | 125.95 | 214.29 | 155.27 | 47.99 | 107.28 | 0.00 | 0.00 |
| November | 55.23 | 307.24 | 108.15 | 33.85 | 74.30 | 0.00 | 0.00 |
| December | 16.71 | 439.25 | 76.56 | 19.28 | 57.27 | 0.00 | 0.00 |
| Annual Sum or Average | 194.44 | 242.24 | 205.69 | 60.75 | 144.94 | 0.00 | 0.00 |
| Minimum of Months | 16.71 | 83.35 | 76.56 | 19.28 | 57.27 | 0.00 | 0.00 |
| Maximum of Months | 427.87 | 516.67 | 339.38 | 112.29 | 234.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 272.75 | 412.99 | 314.22 | 210.10 | 104.12 | 0.00 | 0.00 |
| February | 416.80 | 301.28 | 415.88 | 279.63 | 136.25 | 0.00 | 0.00 |
| March | 414.52 | 261.04 | 407.11 | 209.49 | 197.62 | 0.00 | 0.00 |
| April | 423.79 | 185.95 | 391.21 | 192.59 | 198.62 | 0.00 | 0.00 |
| May | 417.19 | 151.30 | 376.24 | 144.46 | 231.78 | 0.00 | 0.00 |
| June | 509.79 | 116.29 | 422.11 | 170.75 | 251.36 | 0.00 | 0.00 |
| July | 587.36 | 104.93 | 450.13 | 210.93 | 239.21 | 0.00 | 0.00 |
| August | 585.08 | 118.36 | 457.07 | 238.25 | 218.82 | 0.00 | 0.00 |
| September | 521.99 | 166.45 | 436.94 | 255.37 | 181.57 | 0.00 | 0.00 |
| October | 451.64 | 226.51 | 411.34 | 267.06 | 144.29 | 0.00 | 0.00 |
| November | 337.70 | 272.98 | 343.94 | 232.73 | 111.21 | 0.00 | 0.00 |
| December | 262.71 | 351.70 | 291.77 | 197.20 | 94.57 | 0.00 | 0.00 |
| Annual Sum or Average | 433.42 | 222.24 | 392.92 | 216.92 | 176.00 | 0.00 | 0.00 |
| Minimum of Months | 262.71 | 104.93 | 291.77 | 144.46 | 94.57 | 0.00 | 0.00 |
| Maximum of Months | 587.36 | 412.99 | 457.07 | 279.63 | 251.36 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 16.36 | 504.16 | 92.58 | 25.76 | 66.81 | 0.00 | 0.00 |
| February | 65.37 | 361.37 | 139.00 | 43.40 | 95.60 | 0.00 | 0.00 |
| March | 128.63 | 286.74 | 201.08 | 48.41 | 152.67 | 0.00 | 0.00 |
| April | 211.81 | 189.87 | 245.25 | 74.60 | 170.65 | 0.00 | 0.00 |
| May | 289.06 | 145.67 | 290.51 | 80.62 | 209.89 | 0.00 | 0.00 |
| June | 419.29 | 96.49 | 359.45 | 126.26 | 233.18 | 0.00 | 0.00 |
| July | 461.19 | 82.32 | 357.51 | 138.86 | 218.65 | 0.00 | 0.00 |
| August | 371.17 | 93.78 | 302.70 | 112.00 | 190.70 | 0.00 | 0.00 |
| September | 231.67 | 138.44 | 217.81 | 70.80 | 147.01 | 0.00 | 0.00 |
| October | 120.75 | 206.18 | 156.45 | 49.25 | 107.20 | 0.00 | 0.00 |
| November | 41.34 | 299.25 | 102.23 | 29.08 | 73.15 | 0.00 | 0.00 |
| December | 11.32 | 430.37 | 76.84 | 19.81 | 57.03 | 0.00 | 0.00 |
| Annual Sum or Average | 198.10 | 235.80 | 212.17 | 68.37 | 143.80 | 0.00 | 0.00 |
| Minimum of Months | 11.32 | 82.32 | 76.84 | 19.81 | 57.03 | 0.00 | 0.00 |
| Maximum of Months | 461.19 | 504.16 | 359.45 | 138.86 | 233.18 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.87 | 328.78 | 36.72 | 0.00 | 36.72 | 0.00 | 0.00 |
| February | 9.53 | 237.72 | 51.84 | 0.00 | 51.84 | 0.00 | 0.00 |
| March | 33.54 | 185.05 | 84.22 | 0.00 | 84.22 | 0.00 | 0.00 |
| April | 60.96 | 121.88 | 96.31 | 0.73 | 95.59 | 0.00 | 0.00 |
| May | 107.74 | 90.38 | 126.01 | 7.38 | 118.63 | 0.00 | 0.00 |
| June | 158.02 | 59.69 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
| July | 168.35 | 49.92 | 133.96 | 12.38 | 121.58 | 0.00 | 0.00 |
| August | 124.20 | 58.17 | 108.61 | 3.92 | 104.69 | 0.00 | 0.00 |
| September | 73.68 | 89.69 | 80.58 | 0.07 | 80.51 | 0.00 | 0.00 |
| October | 29.64 | 134.68 | 58.72 | 0.00 | 58.72 | 0.00 | 0.00 |
| November | 7.63 | 198.02 | 39.92 | 0.00 | 39.92 | 0.00 | 0.00 |
| December | 0.68 | 280.87 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Annual Sum or Average | 64.91 | 152.60 | 83.03 | 3.45 | 79.58 | 0.00 | 0.00 |
| Minimum of Months | 0.68 | 49.92 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Maximum of Months | 168.35 | 328.78 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.87 | 328.79 | 36.72 | 0.00 | 36.72 | 0.00 | 0.00 |
| February | 9.52 | 237.72 | 51.84 | 0.00 | 51.84 | 0.00 | 0.00 |
| March | 33.52 | 185.05 | 84.22 | 0.00 | 84.22 | 0.00 | 0.00 |
| April | 60.94 | 121.87 | 96.31 | 0.73 | 95.59 | 0.00 | 0.00 |
| May | 107.72 | 90.34 | 126.01 | 7.38 | 118.63 | 0.00 | 0.00 |
| June | 157.94 | 59.69 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
| July | 168.31 | 49.92 | 133.96 | 12.38 | 121.58 | 0.00 | 0.00 |
| August | 124.14 | 58.20 | 108.61 | 3.92 | 104.69 | 0.00 | 0.00 |
| September | 73.63 | 89.71 | 80.58 | 0.07 | 80.51 | 0.00 | 0.00 |
| October | 29.61 | 134.69 | 58.72 | 0.00 | 58.72 | 0.00 | 0.00 |
| November | 7.63 | 198.01 | 39.92 | 0.00 | 39.92 | 0.00 | 0.00 |
| December | 0.68 | 280.87 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Annual Sum or Average | 64.88 | 152.60 | 83.03 | 3.45 | 79.58 | 0.00 | 0.00 |
| Minimum of Months | 0.68 | 49.92 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Maximum of Months | 168.31 | 328.79 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 244.17 | 280.87 | 258.36 | 184.33 | 74.03 | 0.00 | 0.00 |
| February | 345.32 | 206.84 | 328.72 | 236.23 | 92.49 | 0.00 | 0.00 |
| March | 305.79 | 180.11 | 290.25 | 161.09 | 129.17 | 0.00 | 0.00 |
| April | 270.24 | 127.21 | 242.27 | 118.72 | 123.56 | 0.00 | 0.00 |
| May | 241.35 | 99.74 | 211.74 | 71.21 | 140.53 | 0.00 | 0.00 |
| June | 265.21 | 70.48 | 209.32 | 61.24 | 148.09 | 0.00 | 0.00 |
| July | 318.90 | 55.44 | 226.59 | 84.45 | 142.14 | 0.00 | 0.00 |
| August | 357.44 | 63.91 | 262.98 | 130.17 | 132.81 | 0.00 | 0.00 |
| September | 377.55 | 93.99 | 299.71 | 184.64 | 115.07 | 0.00 | 0.00 |
| October | 361.43 | 137.43 | 313.62 | 217.80 | 95.81 | 0.00 | 0.00 |
| November | 297.14 | 176.02 | 281.63 | 203.64 | 77.98 | 0.00 | 0.00 |
| December | 239.10 | 239.74 | 245.72 | 177.39 | 68.32 | 0.00 | 0.00 |
| Annual Sum or Average | 301.61 | 144.10 | 263.78 | 152.00 | 111.77 | 0.00 | 0.00 |
| Minimum of Months | 239.10 | 55.44 | 209.32 | 61.24 | 68.32 | 0.00 | 0.00 |
| Maximum of Months | 377.55 | 280.87 | 328.72 | 236.23 | 148.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 244.53 | 279.72 | 258.36 | 184.33 | 74.03 | 0.00 | 0.00 |
| February | 345.81 | 205.82 | 328.72 | 236.23 | 92.49 | 0.00 | 0.00 |
| March | 306.16 | 179.36 | 290.25 | 161.09 | 129.17 | 0.00 | 0.00 |
| April | 270.38 | 126.89 | 242.27 | 118.72 | 123.56 | 0.00 | 0.00 |
| May | 241.20 | 99.74 | 211.74 | 71.21 | 140.53 | 0.00 | 0.00 |
| June | 264.60 | 71.07 | 209.32 | 61.24 | 148.09 | 0.00 | 0.00 |
| July | 318.32 | 55.98 | 226.59 | 84.45 | 142.14 | 0.00 | 0.00 |
| August | 356.92 | 64.49 | 262.98 | 130.17 | 132.81 | 0.00 | 0.00 |
| September | 377.00 | 94.78 | 299.71 | 184.64 | 115.07 | 0.00 | 0.00 |
| October | 361.19 | 137.79 | 313.62 | 217.80 | 95.81 | 0.00 | 0.00 |
| November | 297.13 | 175.84 | 281.63 | 203.64 | 77.98 | 0.00 | 0.00 |
| December | 239.49 | 238.66 | 245.72 | 177.39 | 68.32 | 0.00 | 0.00 |
| Annual Sum or Average | 301.53 | 143.97 | 263.78 | 152.00 | 111.77 | 0.00 | 0.00 |
| Minimum of Months | 239.49 | 55.98 | 209.32 | 61.24 | 68.32 | 0.00 | 0.00 |
| Maximum of Months | 377.00 | 279.72 | 328.72 | 236.23 | 148.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 248.27 | 480.00 | 308.91 | 204.87 | 104.05 | 0.00 | 0.00 |
| February | 393.46 | 355.14 | 414.38 | 278.38 | 135.99 | 0.00 | 0.00 |
| March | 383.34 | 308.80 | 400.21 | 201.47 | 198.74 | 0.00 | 0.00 |
| April | 399.01 | 225.20 | 385.57 | 182.01 | 203.55 | 0.00 | 0.00 |
| May | 421.47 | 176.19 | 389.01 | 152.08 | 236.93 | 0.00 | 0.00 |
| June | 490.26 | 119.74 | 402.04 | 149.73 | 252.31 | 0.00 | 0.00 |
| July | 575.27 | 93.82 | 424.21 | 184.36 | 239.86 | 0.00 | 0.00 |
| August | 567.30 | 106.07 | 430.43 | 212.13 | 218.30 | 0.00 | 0.00 |
| September | 531.01 | 154.44 | 434.54 | 252.77 | 181.77 | 0.00 | 0.00 |
| October | 448.32 | 226.22 | 410.17 | 265.80 | 144.37 | 0.00 | 0.00 |
| November | 337.66 | 295.47 | 349.85 | 237.49 | 112.36 | 0.00 | 0.00 |
| December | 245.43 | 406.93 | 291.48 | 196.68 | 94.81 | 0.00 | 0.00 |
| Annual Sum or Average | 420.07 | 245.28 | 386.44 | 209.30 | 177.14 | 0.00 | 0.00 |
| Minimum of Months | 245.43 | 93.82 | 291.48 | 149.73 | 94.81 | 0.00 | 0.00 |
| Maximum of Months | 575.27 | 480.00 | 434.54 | 278.38 | 252.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.66 | 534.07 | 87.27 | 20.54 | 66.74 | 0.00 | 0.00 |
| February | 66.02 | 386.02 | 137.49 | 42.15 | 95.34 | 0.00 | 0.00 |
| March | 117.39 | 311.37 | 194.18 | 40.39 | 153.79 | 0.00 | 0.00 |
| April | 196.19 | 216.95 | 239.61 | 64.03 | 175.58 | 0.00 | 0.00 |
| May | 289.50 | 166.35 | 303.28 | 88.25 | 215.04 | 0.00 | 0.00 |
| June | 380.92 | 108.06 | 339.38 | 105.24 | 234.13 | 0.00 | 0.00 |
| July | 423.35 | 86.10 | 331.59 | 112.29 | 219.30 | 0.00 | 0.00 |
| August | 335.23 | 100.08 | 276.06 | 85.88 | 190.18 | 0.00 | 0.00 |
| September | 230.80 | 150.00 | 215.41 | 68.19 | 147.21 | 0.00 | 0.00 |
| October | 122.16 | 221.74 | 155.27 | 47.99 | 107.28 | 0.00 | 0.00 |
| November | 53.20 | 315.94 | 108.15 | 33.85 | 74.30 | 0.00 | 0.00 |
| December | 15.49 | 452.48 | 76.56 | 19.28 | 57.27 | 0.00 | 0.00 |
| Annual Sum or Average | 187.85 | 253.63 | 205.69 | 60.75 | 144.94 | 0.00 | 0.00 |
| Minimum of Months | 15.49 | 86.10 | 76.56 | 19.28 | 57.27 | 0.00 | 0.00 |
| Maximum of Months | 423.35 | 534.07 | 339.38 | 112.29 | 234.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 255.58 | 475.03 | 314.22 | 210.10 | 104.12 | 0.00 | 0.00 |
| February | 393.87 | 351.81 | 415.88 | 279.63 | 136.25 | 0.00 | 0.00 |
| March | 390.92 | 303.92 | 407.11 | 209.49 | 197.62 | 0.00 | 0.00 |
| April | 399.73 | 218.06 | 391.21 | 192.59 | 198.62 | 0.00 | 0.00 |
| May | 399.41 | 169.85 | 376.24 | 144.46 | 231.78 | 0.00 | 0.00 |
| June | 509.98 | 111.76 | 422.11 | 170.75 | 251.36 | 0.00 | 0.00 |
| July | 602.59 | 86.28 | 450.13 | 210.93 | 239.21 | 0.00 | 0.00 |
| August | 596.04 | 99.56 | 457.07 | 238.25 | 218.82 | 0.00 | 0.00 |
| September | 529.56 | 149.08 | 436.94 | 255.37 | 181.57 | 0.00 | 0.00 |
| October | 448.51 | 223.42 | 411.34 | 267.06 | 144.29 | 0.00 | 0.00 |
| November | 328.57 | 291.91 | 343.94 | 232.73 | 111.21 | 0.00 | 0.00 |
| December | 246.42 | 403.92 | 291.77 | 197.20 | 94.57 | 0.00 | 0.00 |
| Annual Sum or Average | 425.17 | 239.99 | 392.92 | 216.92 | 176.00 | 0.00 | 0.00 |
| Minimum of Months | 246.42 | 86.28 | 291.77 | 144.46 | 94.57 | 0.00 | 0.00 |
| Maximum of Months | 602.59 | 475.03 | 457.07 | 279.63 | 251.36 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 14.88 | 521.03 | 92.58 | 25.76 | 66.81 | 0.00 | 0.00 |
| February | 60.82 | 376.92 | 139.00 | 43.40 | 95.60 | 0.00 | 0.00 |
| March | 120.70 | 301.56 | 201.08 | 48.41 | 152.67 | 0.00 | 0.00 |
| April | 196.22 | 209.27 | 245.25 | 74.60 | 170.65 | 0.00 | 0.00 |
| May | 269.90 | 162.59 | 290.51 | 80.62 | 209.89 | 0.00 | 0.00 |
| June | 406.08 | 105.68 | 359.45 | 126.26 | 233.18 | 0.00 | 0.00 |
| July | 456.81 | 84.73 | 357.51 | 138.86 | 218.65 | 0.00 | 0.00 |
| August | 366.92 | 96.78 | 302.70 | 112.00 | 190.70 | 0.00 | 0.00 |
| September | 227.46 | 143.16 | 217.81 | 70.80 | 147.01 | 0.00 | 0.00 |
| October | 116.75 | 213.16 | 156.45 | 49.25 | 107.20 | 0.00 | 0.00 |
| November | 39.44 | 307.57 | 102.23 | 29.08 | 73.15 | 0.00 | 0.00 |
| December | 10.16 | 443.26 | 76.84 | 19.81 | 57.03 | 0.00 | 0.00 |
| Annual Sum or Average | 191.28 | 246.69 | 212.17 | 68.37 | 143.80 | 0.00 | 0.00 |
| Minimum of Months | 10.16 | 84.73 | 76.84 | 19.81 | 57.03 | 0.00 | 0.00 |
| Maximum of Months | 456.81 | 521.03 | 359.45 | 138.86 | 233.18 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.67 | 338.96 | 36.72 | 0.00 | 36.72 | 0.00 | 0.00 |
| February | 8.09 | 247.30 | 51.84 | 0.00 | 51.84 | 0.00 | 0.00 |
| March | 30.23 | 193.95 | 84.22 | 0.00 | 84.22 | 0.00 | 0.00 |
| April | 53.94 | 133.66 | 96.31 | 0.73 | 95.59 | 0.00 | 0.00 |
| May | 97.83 | 100.21 | 126.01 | 7.38 | 118.63 | 0.00 | 0.00 |
| June | 151.51 | 64.36 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
| July | 166.56 | 51.09 | 133.96 | 12.38 | 121.58 | 0.00 | 0.00 |
| August | 122.52 | 59.84 | 108.61 | 3.92 | 104.69 | 0.00 | 0.00 |
| September | 71.93 | 92.91 | 80.58 | 0.07 | 80.51 | 0.00 | 0.00 |
| October | 27.61 | 140.26 | 58.72 | 0.00 | 58.72 | 0.00 | 0.00 |
| November | 7.02 | 203.75 | 39.92 | 0.00 | 39.92 | 0.00 | 0.00 |
| December | 0.52 | 288.86 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Annual Sum or Average | 61.87 | 159.27 | 83.03 | 3.45 | 79.58 | 0.00 | 0.00 |
| Minimum of Months | 0.52 | 51.09 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Maximum of Months | 166.56 | 338.96 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.67 | 338.98 | 36.72 | 0.00 | 36.72 | 0.00 | 0.00 |
| February | 8.08 | 247.29 | 51.84 | 0.00 | 51.84 | 0.00 | 0.00 |
| March | 30.21 | 193.94 | 84.22 | 0.00 | 84.22 | 0.00 | 0.00 |
| April | 53.85 | 133.73 | 96.31 | 0.73 | 95.59 | 0.00 | 0.00 |
| May | 97.78 | 100.19 | 126.01 | 7.38 | 118.63 | 0.00 | 0.00 |
| June | 151.47 | 64.35 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
| July | 166.53 | 51.08 | 133.96 | 12.38 | 121.58 | 0.00 | 0.00 |
| August | 122.48 | 59.84 | 108.61 | 3.92 | 104.69 | 0.00 | 0.00 |
| September | 71.87 | 92.94 | 80.58 | 0.07 | 80.51 | 0.00 | 0.00 |
| October | 27.58 | 140.26 | 58.72 | 0.00 | 58.72 | 0.00 | 0.00 |
| November | 7.01 | 203.73 | 39.92 | 0.00 | 39.92 | 0.00 | 0.00 |
| December | 0.52 | 288.86 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Annual Sum or Average | 61.84 | 159.27 | 83.03 | 3.45 | 79.58 | 0.00 | 0.00 |
| Minimum of Months | 0.52 | 51.08 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Maximum of Months | 166.53 | 338.98 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 240.12 | 289.53 | 258.36 | 184.33 | 74.03 | 0.00 | 0.00 |
| February | 339.10 | 215.69 | 328.72 | 236.23 | 92.49 | 0.00 | 0.00 |
| March | 298.60 | 190.44 | 290.25 | 161.09 | 129.17 | 0.00 | 0.00 |
| April | 260.49 | 141.75 | 242.27 | 118.72 | 123.56 | 0.00 | 0.00 |
| May | 232.43 | 110.20 | 211.74 | 71.21 | 140.53 | 0.00 | 0.00 |
| June | 260.61 | 74.85 | 209.32 | 61.24 | 148.09 | 0.00 | 0.00 |
| July | 317.14 | 56.37 | 226.59 | 84.45 | 142.14 | 0.00 | 0.00 |
| August | 355.69 | 64.81 | 262.98 | 130.17 | 132.81 | 0.00 | 0.00 |
| September | 375.26 | 95.50 | 299.71 | 184.64 | 115.07 | 0.00 | 0.00 |
| October | 358.45 | 140.43 | 313.62 | 217.80 | 95.81 | 0.00 | 0.00 |
| November | 293.24 | 181.64 | 281.63 | 203.64 | 77.98 | 0.00 | 0.00 |
| December | 235.46 | 246.06 | 245.72 | 177.39 | 68.32 | 0.00 | 0.00 |
| Annual Sum or Average | 296.87 | 150.37 | 263.78 | 152.00 | 111.77 | 0.00 | 0.00 |
| Minimum of Months | 232.43 | 56.37 | 209.32 | 61.24 | 68.32 | 0.00 | 0.00 |
| Maximum of Months | 375.26 | 289.53 | 328.72 | 236.23 | 148.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 240.10 | 289.54 | 258.36 | 184.33 | 74.03 | 0.00 | 0.00 |
| February | 339.07 | 215.69 | 328.72 | 236.23 | 92.49 | 0.00 | 0.00 |
| March | 298.54 | 190.47 | 290.25 | 161.09 | 129.17 | 0.00 | 0.00 |
| April | 260.43 | 141.78 | 242.27 | 118.72 | 123.56 | 0.00 | 0.00 |
| May | 232.40 | 110.17 | 211.74 | 71.21 | 140.53 | 0.00 | 0.00 |
| June | 260.58 | 74.84 | 209.32 | 61.24 | 148.09 | 0.00 | 0.00 |
| July | 317.11 | 56.36 | 226.59 | 84.45 | 142.14 | 0.00 | 0.00 |
| August | 355.66 | 64.81 | 262.98 | 130.17 | 132.81 | 0.00 | 0.00 |
| September | 375.23 | 95.51 | 299.71 | 184.64 | 115.07 | 0.00 | 0.00 |
| October | 358.42 | 140.42 | 313.62 | 217.80 | 95.81 | 0.00 | 0.00 |
| November | 293.22 | 181.62 | 281.63 | 203.64 | 77.98 | 0.00 | 0.00 |
| December | 235.45 | 246.06 | 245.72 | 177.39 | 68.32 | 0.00 | 0.00 |
| Annual Sum or Average | 296.84 | 150.37 | 263.78 | 152.00 | 111.77 | 0.00 | 0.00 |
| Minimum of Months | 232.40 | 56.36 | 209.32 | 61.24 | 68.32 | 0.00 | 0.00 |
| Maximum of Months | 375.23 | 289.54 | 328.72 | 236.23 | 148.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 248.56 | 466.92 | 308.91 | 204.87 | 104.05 | 0.00 | 0.00 |
| February | 392.62 | 343.81 | 414.38 | 278.38 | 135.99 | 0.00 | 0.00 |
| March | 381.57 | 297.55 | 400.21 | 201.47 | 198.74 | 0.00 | 0.00 |
| April | 398.83 | 212.07 | 385.57 | 182.01 | 203.55 | 0.00 | 0.00 |
| May | 420.08 | 166.05 | 389.01 | 152.08 | 236.93 | 0.00 | 0.00 |
| June | 489.62 | 110.17 | 402.04 | 149.73 | 252.31 | 0.00 | 0.00 |
| July | 571.26 | 88.63 | 424.21 | 184.36 | 239.86 | 0.00 | 0.00 |
| August | 564.33 | 98.92 | 430.43 | 212.13 | 218.30 | 0.00 | 0.00 |
| September | 530.27 | 142.73 | 434.54 | 252.77 | 181.77 | 0.00 | 0.00 |
| October | 451.54 | 207.93 | 410.17 | 265.80 | 144.37 | 0.00 | 0.00 |
| November | 339.17 | 282.09 | 349.85 | 237.49 | 112.36 | 0.00 | 0.00 |
| December | 246.05 | 394.73 | 291.48 | 196.68 | 94.81 | 0.00 | 0.00 |
| Annual Sum or Average | 419.49 | 233.92 | 386.44 | 209.30 | 177.14 | 0.00 | 0.00 |
| Minimum of Months | 246.05 | 88.63 | 291.48 | 149.73 | 94.81 | 0.00 | 0.00 |
| Maximum of Months | 571.26 | 466.92 | 434.54 | 278.38 | 252.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 16.09 | 520.46 | 87.27 | 20.54 | 66.74 | 0.00 | 0.00 |
| February | 66.52 | 375.06 | 137.49 | 42.15 | 95.34 | 0.00 | 0.00 |
| March | 117.68 | 301.61 | 194.18 | 40.39 | 153.79 | 0.00 | 0.00 |
| April | 196.26 | 207.62 | 239.61 | 64.03 | 175.58 | 0.00 | 0.00 |
| May | 289.38 | 157.99 | 303.28 | 88.25 | 215.04 | 0.00 | 0.00 |
| June | 382.84 | 100.39 | 339.38 | 105.24 | 234.13 | 0.00 | 0.00 |
| July | 421.37 | 82.16 | 331.59 | 112.29 | 219.30 | 0.00 | 0.00 |
| August | 334.71 | 93.47 | 276.06 | 85.88 | 190.18 | 0.00 | 0.00 |
| September | 231.74 | 140.03 | 215.41 | 68.19 | 147.21 | 0.00 | 0.00 |
| October | 125.23 | 208.11 | 155.27 | 47.99 | 107.28 | 0.00 | 0.00 |
| November | 54.26 | 304.65 | 108.15 | 33.85 | 74.30 | 0.00 | 0.00 |
| December | 15.97 | 439.41 | 76.56 | 19.28 | 57.27 | 0.00 | 0.00 |
| Annual Sum or Average | 188.35 | 243.79 | 205.69 | 60.75 | 144.94 | 0.00 | 0.00 |
| Minimum of Months | 15.97 | 82.16 | 76.56 | 19.28 | 57.27 | 0.00 | 0.00 |
| Maximum of Months | 421.37 | 520.46 | 339.38 | 112.29 | 234.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 256.00 | 461.86 | 314.22 | 210.10 | 104.12 | 0.00 | 0.00 |
| February | 393.05 | 340.44 | 415.88 | 279.63 | 136.25 | 0.00 | 0.00 |
| March | 389.34 | 292.70 | 407.11 | 209.49 | 197.62 | 0.00 | 0.00 |
| April | 399.79 | 205.24 | 391.21 | 192.59 | 198.62 | 0.00 | 0.00 |
| May | 398.23 | 160.40 | 376.24 | 144.46 | 231.78 | 0.00 | 0.00 |
| June | 509.35 | 103.59 | 422.11 | 170.75 | 251.36 | 0.00 | 0.00 |
| July | 598.33 | 81.83 | 450.13 | 210.93 | 239.21 | 0.00 | 0.00 |
| August | 592.97 | 93.34 | 457.07 | 238.25 | 218.82 | 0.00 | 0.00 |
| September | 528.93 | 137.94 | 436.94 | 255.37 | 181.57 | 0.00 | 0.00 |
| October | 451.49 | 205.38 | 411.34 | 267.06 | 144.29 | 0.00 | 0.00 |
| November | 330.26 | 278.34 | 343.94 | 232.73 | 111.21 | 0.00 | 0.00 |
| December | 247.08 | 391.62 | 291.77 | 197.20 | 94.57 | 0.00 | 0.00 |
| Annual Sum or Average | 424.63 | 229.00 | 392.92 | 216.92 | 176.00 | 0.00 | 0.00 |
| Minimum of Months | 247.08 | 81.83 | 291.77 | 144.46 | 94.57 | 0.00 | 0.00 |
| Maximum of Months | 598.33 | 461.86 | 457.07 | 279.63 | 251.36 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.60 | 507.48 | 92.58 | 25.76 | 66.81 | 0.00 | 0.00 |
| February | 61.98 | 366.41 | 139.00 | 43.40 | 95.60 | 0.00 | 0.00 |
| March | 121.64 | 292.18 | 201.08 | 48.41 | 152.67 | 0.00 | 0.00 |
| April | 196.40 | 199.97 | 245.25 | 74.60 | 170.65 | 0.00 | 0.00 |
| May | 269.37 | 154.19 | 290.51 | 80.62 | 209.89 | 0.00 | 0.00 |
| June | 406.53 | 98.11 | 359.45 | 126.26 | 233.18 | 0.00 | 0.00 |
| July | 453.64 | 80.52 | 357.51 | 138.86 | 218.65 | 0.00 | 0.00 |
| August | 365.76 | 90.70 | 302.70 | 112.00 | 190.70 | 0.00 | 0.00 |
| September | 228.78 | 133.65 | 217.81 | 70.80 | 147.01 | 0.00 | 0.00 |
| October | 120.69 | 199.86 | 156.45 | 49.25 | 107.20 | 0.00 | 0.00 |
| November | 41.03 | 296.67 | 102.23 | 29.08 | 73.15 | 0.00 | 0.00 |
| December | 10.95 | 430.37 | 76.84 | 19.81 | 57.03 | 0.00 | 0.00 |
| Annual Sum or Average | 191.79 | 237.06 | 212.17 | 68.37 | 143.80 | 0.00 | 0.00 |
| Minimum of Months | 10.95 | 80.52 | 76.84 | 19.81 | 57.03 | 0.00 | 0.00 |
| Maximum of Months | 453.64 | 507.48 | 359.45 | 138.86 | 233.18 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.76 | 331.08 | 36.72 | 0.00 | 36.72 | 0.00 | 0.00 |
| February | 8.51 | 240.91 | 51.84 | 0.00 | 51.84 | 0.00 | 0.00 |
| March | 30.82 | 188.45 | 84.22 | 0.00 | 84.22 | 0.00 | 0.00 |
| April | 54.65 | 128.04 | 96.31 | 0.73 | 95.59 | 0.00 | 0.00 |
| May | 98.27 | 95.86 | 126.01 | 7.38 | 118.63 | 0.00 | 0.00 |
| June | 152.97 | 60.58 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
| July | 165.53 | 49.49 | 133.96 | 12.38 | 121.58 | 0.00 | 0.00 |
| August | 122.52 | 56.72 | 108.61 | 3.92 | 104.69 | 0.00 | 0.00 |
| September | 73.25 | 86.65 | 80.58 | 0.07 | 80.51 | 0.00 | 0.00 |
| October | 30.37 | 130.28 | 58.72 | 0.00 | 58.72 | 0.00 | 0.00 |
| November | 7.58 | 196.48 | 39.92 | 0.00 | 39.92 | 0.00 | 0.00 |
| December | 0.62 | 281.12 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Annual Sum or Average | 62.49 | 153.48 | 83.03 | 3.45 | 79.58 | 0.00 | 0.00 |
| Minimum of Months | 0.62 | 49.49 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Maximum of Months | 165.53 | 331.08 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.75 | 331.09 | 36.72 | 0.00 | 36.72 | 0.00 | 0.00 |
| February | 8.49 | 240.88 | 51.84 | 0.00 | 51.84 | 0.00 | 0.00 |
| March | 30.77 | 188.41 | 84.22 | 0.00 | 84.22 | 0.00 | 0.00 |
| April | 54.47 | 128.02 | 96.31 | 0.73 | 95.59 | 0.00 | 0.00 |
| May | 98.13 | 95.79 | 126.01 | 7.38 | 118.63 | 0.00 | 0.00 |
| June | 152.80 | 60.55 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
| July | 165.43 | 49.45 | 133.96 | 12.38 | 121.58 | 0.00 | 0.00 |
| August | 122.39 | 56.70 | 108.61 | 3.92 | 104.69 | 0.00 | 0.00 |
| September | 73.13 | 86.61 | 80.58 | 0.07 | 80.51 | 0.00 | 0.00 |
| October | 30.31 | 130.20 | 58.72 | 0.00 | 58.72 | 0.00 | 0.00 |
| November | 7.57 | 196.45 | 39.92 | 0.00 | 39.92 | 0.00 | 0.00 |
| December | 0.62 | 281.12 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Annual Sum or Average | 62.40 | 153.45 | 83.03 | 3.45 | 79.58 | 0.00 | 0.00 |
| Minimum of Months | 0.62 | 49.45 | 30.79 | 0.00 | 30.79 | 0.00 | 0.00 |
| Maximum of Months | 165.43 | 331.09 | 146.66 | 16.75 | 129.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 240.43 | 281.83 | 258.36 | 184.33 | 74.03 | 0.00 | 0.00 |
| February | 338.88 | 208.93 | 328.72 | 236.23 | 92.49 | 0.00 | 0.00 |
| March | 298.17 | 183.33 | 290.25 | 161.09 | 129.17 | 0.00 | 0.00 |
| April | 261.29 | 132.91 | 242.27 | 118.72 | 123.56 | 0.00 | 0.00 |
| May | 232.00 | 104.89 | 211.74 | 71.21 | 140.53 | 0.00 | 0.00 |
| June | 260.37 | 69.91 | 209.32 | 61.24 | 148.09 | 0.00 | 0.00 |
| July | 314.88 | 54.11 | 226.59 | 84.45 | 142.14 | 0.00 | 0.00 |
| August | 354.02 | 61.44 | 262.98 | 130.17 | 132.81 | 0.00 | 0.00 |
| September | 375.31 | 88.53 | 299.71 | 184.64 | 115.07 | 0.00 | 0.00 |
| October | 361.04 | 128.63 | 313.62 | 217.80 | 95.81 | 0.00 | 0.00 |
| November | 295.27 | 171.99 | 281.63 | 203.64 | 77.98 | 0.00 | 0.00 |
| December | 235.92 | 238.94 | 245.72 | 177.39 | 68.32 | 0.00 | 0.00 |
| Annual Sum or Average | 296.95 | 143.56 | 263.78 | 152.00 | 111.77 | 0.00 | 0.00 |
| Minimum of Months | 232.00 | 54.11 | 209.32 | 61.24 | 68.32 | 0.00 | 0.00 |
| Maximum of Months | 375.31 | 281.83 | 328.72 | 236.23 | 148.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 240.40 | 281.82 | 258.36 | 184.33 | 74.03 | 0.00 | 0.00 |
| February | 338.83 | 208.89 | 328.72 | 236.23 | 92.49 | 0.00 | 0.00 |
| March | 298.08 | 183.30 | 290.25 | 161.09 | 129.17 | 0.00 | 0.00 |
| April | 261.16 | 132.87 | 242.27 | 118.72 | 123.56 | 0.00 | 0.00 |
| May | 231.87 | 104.80 | 211.74 | 71.21 | 140.53 | 0.00 | 0.00 |
| June | 260.23 | 69.86 | 209.32 | 61.24 | 148.09 | 0.00 | 0.00 |
| July | 314.79 | 54.07 | 226.59 | 84.45 | 142.14 | 0.00 | 0.00 |
| August | 353.92 | 61.41 | 262.98 | 130.17 | 132.81 | 0.00 | 0.00 |
| September | 375.22 | 88.50 | 299.71 | 184.64 | 115.07 | 0.00 | 0.00 |
| October | 360.96 | 128.60 | 313.62 | 217.80 | 95.81 | 0.00 | 0.00 |
| November | 295.24 | 171.94 | 281.63 | 203.64 | 77.98 | 0.00 | 0.00 |
| December | 235.90 | 238.93 | 245.72 | 177.39 | 68.32 | 0.00 | 0.00 |
| Annual Sum or Average | 296.86 | 143.52 | 263.78 | 152.00 | 111.77 | 0.00 | 0.00 |
| Minimum of Months | 231.87 | 54.07 | 209.32 | 61.24 | 68.32 | 0.00 | 0.00 |
| Maximum of Months | 375.22 | 281.82 | 328.72 | 236.23 | 148.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 6.94 | 47.93 | 13.40 | 6.18 | 7.22 | 0.00 | 0.00 |
| February | 15.56 | 35.66 | 20.91 | 10.41 | 10.50 | 0.00 | 0.00 |
| March | 22.99 | 28.93 | 28.04 | 11.61 | 16.43 | 0.00 | 0.00 |
| April | 35.05 | 20.79 | 35.74 | 17.73 | 18.01 | 0.00 | 0.00 |
| May | 41.14 | 16.62 | 39.47 | 17.58 | 21.90 | 0.00 | 0.00 |
| June | 60.65 | 11.09 | 51.06 | 26.28 | 24.78 | 0.00 | 0.00 |
| July | 68.52 | 9.06 | 53.64 | 30.35 | 23.29 | 0.00 | 0.00 |
| August | 57.97 | 10.17 | 46.57 | 25.93 | 20.64 | 0.00 | 0.00 |
| September | 37.55 | 14.45 | 32.93 | 16.97 | 15.96 | 0.00 | 0.00 |
| October | 22.51 | 21.07 | 23.45 | 11.82 | 11.63 | 0.00 | 0.00 |
| November | 10.47 | 29.55 | 14.95 | 6.98 | 7.97 | 0.00 | 0.00 |
| December | 5.42 | 41.12 | 11.05 | 4.75 | 6.30 | 0.00 | 0.00 |
| Annual Sum or Average | 32.16 | 23.83 | 30.99 | 15.58 | 15.41 | 0.00 | 0.00 |
| Minimum of Months | 5.42 | 9.06 | 11.05 | 4.75 | 6.30 | 0.00 | 0.00 |
| Maximum of Months | 68.52 | 47.93 | 53.64 | 30.35 | 24.78 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 22.81 | 126.20 | 39.92 | 18.41 | 21.51 | 0.00 | 0.00 |
| February | 50.10 | 93.49 | 62.29 | 31.01 | 31.27 | 0.00 | 0.00 |
| March | 73.81 | 76.77 | 83.51 | 34.59 | 48.92 | 0.00 | 0.00 |
| April | 110.53 | 54.56 | 106.43 | 52.79 | 53.64 | 0.00 | 0.00 |
| May | 129.00 | 43.75 | 117.56 | 52.35 | 65.22 | 0.00 | 0.00 |
| June | 183.40 | 31.61 | 152.07 | 78.26 | 73.80 | 0.00 | 0.00 |
| July | 204.47 | 27.51 | 159.76 | 90.38 | 69.37 | 0.00 | 0.00 |
| August | 173.17 | 30.87 | 138.70 | 77.24 | 61.46 | 0.00 | 0.00 |
| September | 112.46 | 43.36 | 98.07 | 50.55 | 47.52 | 0.00 | 0.00 |
| October | 67.78 | 61.68 | 69.84 | 35.20 | 34.64 | 0.00 | 0.00 |
| November | 32.60 | 81.96 | 44.53 | 20.78 | 23.75 | 0.00 | 0.00 |
| December | 17.71 | 109.87 | 32.91 | 14.16 | 18.75 | 0.00 | 0.00 |
| Annual Sum or Average | 98.42 | 65.04 | 92.29 | 46.39 | 45.90 | 0.00 | 0.00 |
| Minimum of Months | 17.71 | 27.51 | 32.91 | 14.16 | 18.75 | 0.00 | 0.00 |
| Maximum of Months | 204.47 | 126.20 | 159.76 | 90.38 | 73.80 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 6.59 | 51.02 | 13.40 | 6.18 | 7.22 | 0.00 | 0.00 |
| February | 15.04 | 37.90 | 20.91 | 10.41 | 10.50 | 0.00 | 0.00 |
| March | 22.31 | 30.82 | 28.04 | 11.61 | 16.43 | 0.00 | 0.00 |
| April | 34.35 | 22.36 | 35.74 | 17.73 | 18.01 | 0.00 | 0.00 |
| May | 40.57 | 17.63 | 39.47 | 17.58 | 21.90 | 0.00 | 0.00 |
| June | 60.04 | 11.75 | 51.06 | 26.28 | 24.78 | 0.00 | 0.00 |
| July | 68.44 | 9.37 | 53.64 | 30.35 | 23.29 | 0.00 | 0.00 |
| August | 57.69 | 10.69 | 46.57 | 25.93 | 20.64 | 0.00 | 0.00 |
| September | 36.95 | 15.58 | 32.93 | 16.97 | 15.96 | 0.00 | 0.00 |
| October | 21.53 | 23.10 | 23.45 | 11.82 | 11.63 | 0.00 | 0.00 |
| November | 9.88 | 31.88 | 14.95 | 6.98 | 7.97 | 0.00 | 0.00 |
| December | 5.08 | 43.92 | 11.05 | 4.75 | 6.30 | 0.00 | 0.00 |
| Annual Sum or Average | 31.63 | 25.45 | 30.99 | 15.58 | 15.41 | 0.00 | 0.00 |
| Minimum of Months | 5.08 | 9.37 | 11.05 | 4.75 | 6.30 | 0.00 | 0.00 |
| Maximum of Months | 68.44 | 51.02 | 53.64 | 30.35 | 24.78 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.681056E+09 | 0.124533E+10 | 0.827397E+09 | 0.548722E+09 | 0.278675E+09 | 0.00 | 0.00 |
| February | 0.976088E+09 | 0.822503E+09 | 0.100246E+10 | 0.673465E+09 | 0.328992E+09 | 0.00 | 0.00 |
| March | 0.105979E+10 | 0.781786E+09 | 0.107192E+10 | 0.539625E+09 | 0.532296E+09 | 0.00 | 0.00 |
| April | 0.108050E+10 | 0.525089E+09 | 0.999385E+09 | 0.471778E+09 | 0.527606E+09 | 0.00 | 0.00 |
| May | 0.117591E+10 | 0.424756E+09 | 0.104193E+10 | 0.407335E+09 | 0.634593E+09 | 0.00 | 0.00 |
| June | 0.129859E+10 | 0.286887E+09 | 0.104209E+10 | 0.388097E+09 | 0.653997E+09 | 0.00 | 0.00 |
| July | 0.155182E+10 | 0.244892E+09 | 0.113622E+10 | 0.493787E+09 | 0.642429E+09 | 0.00 | 0.00 |
| August | 0.152969E+10 | 0.277864E+09 | 0.115288E+10 | 0.568170E+09 | 0.584706E+09 | 0.00 | 0.00 |
| September | 0.138721E+10 | 0.392616E+09 | 0.112632E+10 | 0.655170E+09 | 0.471148E+09 | 0.00 | 0.00 |
| October | 0.121343E+10 | 0.593109E+09 | 0.109860E+10 | 0.711916E+09 | 0.386683E+09 | 0.00 | 0.00 |
| November | 0.889887E+09 | 0.743944E+09 | 0.906820E+09 | 0.615581E+09 | 0.291238E+09 | 0.00 | 0.00 |
| December | 0.671268E+09 | 0.106083E+10 | 0.780713E+09 | 0.526778E+09 | 0.253935E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.135152E+11 | 0.739960E+10 | 0.121867E+11 | 0.660042E+10 | 0.558630E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.671268E+09 | 0.244892E+09 | 0.780713E+09 | 0.388097E+09 | 0.253935E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.155182E+10 | 0.124533E+10 | 0.115288E+10 | 0.711916E+09 | 0.653997E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 45991040.71 | 0.138384E+10 | 0.233749E+09 | 55002115.31 | 0.178747E+09 | 0.00 | 0.00 |
| February | 0.170161E+09 | 0.894871E+09 | 0.332625E+09 | 0.101978E+09 | 0.230648E+09 | 0.00 | 0.00 |
| March | 0.335039E+09 | 0.791812E+09 | 0.520094E+09 | 0.108181E+09 | 0.411913E+09 | 0.00 | 0.00 |
| April | 0.545539E+09 | 0.511219E+09 | 0.621056E+09 | 0.165953E+09 | 0.455103E+09 | 0.00 | 0.00 |
| May | 0.824304E+09 | 0.398797E+09 | 0.812315E+09 | 0.236364E+09 | 0.575950E+09 | 0.00 | 0.00 |
| June | 0.102238E+10 | 0.255028E+09 | 0.879667E+09 | 0.272794E+09 | 0.606873E+09 | 0.00 | 0.00 |
| July | 0.114601E+10 | 0.223235E+09 | 0.888121E+09 | 0.300761E+09 | 0.587360E+09 | 0.00 | 0.00 |
| August | 0.909177E+09 | 0.258214E+09 | 0.739410E+09 | 0.230019E+09 | 0.509391E+09 | 0.00 | 0.00 |
| September | 0.608092E+09 | 0.375491E+09 | 0.558336E+09 | 0.176757E+09 | 0.381579E+09 | 0.00 | 0.00 |
| October | 0.337348E+09 | 0.573968E+09 | 0.415887E+09 | 0.128549E+09 | 0.287338E+09 | 0.00 | 0.00 |
| November | 0.143165E+09 | 0.796357E+09 | 0.280315E+09 | 87739504.81 | 0.192575E+09 | 0.00 | 0.00 |
| December | 44743164.48 | 0.117649E+10 | 0.205054E+09 | 51652699.56 | 0.153401E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.613195E+10 | 0.763932E+10 | 0.648663E+10 | 0.191575E+10 | 0.457088E+10 | 0.00 | 0.00 |
| Minimum of Months | 44743164.48 | 0.223235E+09 | 0.205054E+09 | 51652699.56 | 0.153401E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.114601E+10 | 0.138384E+10 | 0.888121E+09 | 0.300761E+09 | 0.606873E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.730526E+09 | 0.110615E+10 | 0.841605E+09 | 0.562724E+09 | 0.278881E+09 | 0.00 | 0.00 |
| February | 0.100832E+10 | 0.728867E+09 | 0.100610E+10 | 0.676469E+09 | 0.329627E+09 | 0.00 | 0.00 |
| March | 0.111025E+10 | 0.699174E+09 | 0.109040E+10 | 0.561097E+09 | 0.529306E+09 | 0.00 | 0.00 |
| April | 0.109846E+10 | 0.481983E+09 | 0.101401E+10 | 0.499188E+09 | 0.514824E+09 | 0.00 | 0.00 |
| May | 0.111740E+10 | 0.405250E+09 | 0.100772E+10 | 0.386911E+09 | 0.620813E+09 | 0.00 | 0.00 |
| June | 0.132137E+10 | 0.301417E+09 | 0.109411E+10 | 0.442580E+09 | 0.651531E+09 | 0.00 | 0.00 |
| July | 0.157319E+10 | 0.281041E+09 | 0.120564E+10 | 0.564943E+09 | 0.640696E+09 | 0.00 | 0.00 |
| August | 0.156707E+10 | 0.317017E+09 | 0.122421E+10 | 0.638133E+09 | 0.586078E+09 | 0.00 | 0.00 |
| September | 0.135300E+10 | 0.431439E+09 | 0.113255E+10 | 0.661924E+09 | 0.470629E+09 | 0.00 | 0.00 |
| October | 0.120968E+10 | 0.606686E+09 | 0.110174E+10 | 0.715282E+09 | 0.386458E+09 | 0.00 | 0.00 |
| November | 0.875306E+09 | 0.707559E+09 | 0.891493E+09 | 0.603226E+09 | 0.288266E+09 | 0.00 | 0.00 |
| December | 0.703643E+09 | 0.941983E+09 | 0.781475E+09 | 0.528186E+09 | 0.253289E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.136682E+11 | 0.700856E+10 | 0.123911E+11 | 0.684066E+10 | 0.555040E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.703643E+09 | 0.281041E+09 | 0.781475E+09 | 0.386911E+09 | 0.253289E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.157319E+10 | 0.110615E+10 | 0.122421E+10 | 0.715282E+09 | 0.651531E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 43826690.57 | 0.135033E+10 | 0.247957E+09 | 69004258.54 | 0.178953E+09 | 0.00 | 0.00 |
| February | 0.158139E+09 | 0.874235E+09 | 0.336264E+09 | 0.104982E+09 | 0.231283E+09 | 0.00 | 0.00 |
| March | 0.344518E+09 | 0.768013E+09 | 0.538576E+09 | 0.129653E+09 | 0.408923E+09 | 0.00 | 0.00 |
| April | 0.549022E+09 | 0.492140E+09 | 0.635684E+09 | 0.193363E+09 | 0.442321E+09 | 0.00 | 0.00 |
| May | 0.774225E+09 | 0.390167E+09 | 0.778110E+09 | 0.215940E+09 | 0.562170E+09 | 0.00 | 0.00 |
| June | 0.108680E+10 | 0.250093E+09 | 0.931684E+09 | 0.327277E+09 | 0.604407E+09 | 0.00 | 0.00 |
| July | 0.123525E+10 | 0.220481E+09 | 0.957544E+09 | 0.371917E+09 | 0.585627E+09 | 0.00 | 0.00 |
| August | 0.994146E+09 | 0.251191E+09 | 0.810745E+09 | 0.299983E+09 | 0.510762E+09 | 0.00 | 0.00 |
| September | 0.600482E+09 | 0.358825E+09 | 0.564571E+09 | 0.183511E+09 | 0.381060E+09 | 0.00 | 0.00 |
| October | 0.323421E+09 | 0.552223E+09 | 0.419027E+09 | 0.131915E+09 | 0.287112E+09 | 0.00 | 0.00 |
| November | 0.107157E+09 | 0.775665E+09 | 0.264988E+09 | 75384451.24 | 0.189603E+09 | 0.00 | 0.00 |
| December | 30316330.04 | 0.115270E+10 | 0.205815E+09 | 53060374.77 | 0.152755E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.624730E+10 | 0.743607E+10 | 0.669097E+10 | 0.215599E+10 | 0.453498E+10 | 0.00 | 0.00 |
| Minimum of Months | 30316330.04 | 0.220481E+09 | 0.205815E+09 | 53060374.77 | 0.152755E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.123525E+10 | 0.135033E+10 | 0.957544E+09 | 0.371917E+09 | 0.604407E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 2335659.65 | 0.880594E+09 | 98341482.54 | 0.00 | 98341482.54 | 0.00 | 0.00 |
| February | 23046104.12 | 0.575102E+09 | 0.125415E+09 | 0.00 | 0.125415E+09 | 0.00 | 0.00 |
| March | 89822033.10 | 0.495632E+09 | 0.225586E+09 | 11702.76 | 0.225574E+09 | 0.00 | 0.00 |
| April | 0.158004E+09 | 0.315900E+09 | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.00 | 0.00 |
| May | 0.288558E+09 | 0.242068E+09 | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.00 | 0.00 |
| June | 0.409584E+09 | 0.154706E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
| July | 0.450920E+09 | 0.133708E+09 | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.00 | 0.00 |
| August | 0.332661E+09 | 0.155806E+09 | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.00 | 0.00 |
| September | 0.190980E+09 | 0.232484E+09 | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.00 | 0.00 |
| October | 79376625.63 | 0.360737E+09 | 0.157280E+09 | 0.00 | 0.157280E+09 | 0.00 | 0.00 |
| November | 19784885.74 | 0.513266E+09 | 0.103471E+09 | 0.00 | 0.103471E+09 | 0.00 | 0.00 |
| December | 1812010.65 | 0.752282E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Annual Sum or Average | 0.204688E+10 | 0.481229E+10 | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.00 | 0.00 |
| Minimum of Months | 1812010.65 | 0.133708E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Maximum of Months | 0.450920E+09 | 0.880594E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 2333537.22 | 0.880618E+09 | 98341482.54 | 0.00 | 98341482.54 | 0.00 | 0.00 |
| February | 23030200.16 | 0.575098E+09 | 0.125415E+09 | 0.00 | 0.125415E+09 | 0.00 | 0.00 |
| March | 89788523.51 | 0.495630E+09 | 0.225586E+09 | 11702.76 | 0.225574E+09 | 0.00 | 0.00 |
| April | 0.157949E+09 | 0.315889E+09 | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.00 | 0.00 |
| May | 0.288529E+09 | 0.241977E+09 | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.00 | 0.00 |
| June | 0.409387E+09 | 0.154723E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
| July | 0.450811E+09 | 0.133712E+09 | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.00 | 0.00 |
| August | 0.332496E+09 | 0.155892E+09 | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.00 | 0.00 |
| September | 0.190861E+09 | 0.232541E+09 | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.00 | 0.00 |
| October | 79309301.19 | 0.360755E+09 | 0.157280E+09 | 0.00 | 0.157280E+09 | 0.00 | 0.00 |
| November | 19777972.03 | 0.513241E+09 | 0.103471E+09 | 0.00 | 0.103471E+09 | 0.00 | 0.00 |
| December | 1810893.78 | 0.752283E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Annual Sum or Average | 0.204608E+10 | 0.481236E+10 | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.00 | 0.00 |
| Minimum of Months | 1810893.78 | 0.133712E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Maximum of Months | 0.450811E+09 | 0.880618E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.653992E+09 | 0.752280E+09 | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.00 | 0.00 |
| February | 0.835408E+09 | 0.500389E+09 | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.00 | 0.00 |
| March | 0.819041E+09 | 0.482411E+09 | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.00 | 0.00 |
| April | 0.700462E+09 | 0.329735E+09 | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.00 | 0.00 |
| May | 0.646440E+09 | 0.267154E+09 | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.00 | 0.00 |
| June | 0.687437E+09 | 0.182693E+09 | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.00 | 0.00 |
| July | 0.854141E+09 | 0.148488E+09 | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.00 | 0.00 |
| August | 0.957369E+09 | 0.171176E+09 | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.00 | 0.00 |
| September | 0.978604E+09 | 0.243634E+09 | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.00 | 0.00 |
| October | 0.968058E+09 | 0.368102E+09 | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.00 | 0.00 |
| November | 0.770180E+09 | 0.456240E+09 | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.00 | 0.00 |
| December | 0.640407E+09 | 0.642126E+09 | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.951154E+10 | 0.454443E+10 | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.640407E+09 | 0.148488E+09 | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.978604E+09 | 0.752280E+09 | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.654953E+09 | 0.749209E+09 | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.00 | 0.00 |
| February | 0.836579E+09 | 0.497919E+09 | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.00 | 0.00 |
| March | 0.820028E+09 | 0.480392E+09 | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.00 | 0.00 |
| April | 0.700835E+09 | 0.328896E+09 | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.00 | 0.00 |
| May | 0.646042E+09 | 0.267154E+09 | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.00 | 0.00 |
| June | 0.685849E+09 | 0.184215E+09 | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.00 | 0.00 |
| July | 0.852580E+09 | 0.149944E+09 | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.00 | 0.00 |
| August | 0.955966E+09 | 0.172726E+09 | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.00 | 0.00 |
| September | 0.977194E+09 | 0.245663E+09 | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.00 | 0.00 |
| October | 0.967417E+09 | 0.369070E+09 | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.00 | 0.00 |
| November | 0.770160E+09 | 0.455774E+09 | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.00 | 0.00 |
| December | 0.641459E+09 | 0.639227E+09 | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.950906E+10 | 0.454019E+10 | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.641459E+09 | 0.149944E+09 | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.977194E+09 | 0.749209E+09 | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.664977E+09 | 0.128563E+10 | 0.827397E+09 | 0.548722E+09 | 0.278675E+09 | 0.00 | 0.00 |
| February | 0.951864E+09 | 0.859149E+09 | 0.100246E+10 | 0.673465E+09 | 0.328992E+09 | 0.00 | 0.00 |
| March | 0.102673E+10 | 0.827097E+09 | 0.107192E+10 | 0.539625E+09 | 0.532296E+09 | 0.00 | 0.00 |
| April | 0.103424E+10 | 0.583730E+09 | 0.999385E+09 | 0.471778E+09 | 0.527606E+09 | 0.00 | 0.00 |
| May | 0.112888E+10 | 0.471908E+09 | 0.104193E+10 | 0.407335E+09 | 0.634593E+09 | 0.00 | 0.00 |
| June | 0.127075E+10 | 0.310359E+09 | 0.104209E+10 | 0.388097E+09 | 0.653997E+09 | 0.00 | 0.00 |
| July | 0.154080E+10 | 0.251295E+09 | 0.113622E+10 | 0.493787E+09 | 0.642429E+09 | 0.00 | 0.00 |
| August | 0.151945E+10 | 0.284093E+09 | 0.115288E+10 | 0.568170E+09 | 0.584706E+09 | 0.00 | 0.00 |
| September | 0.137639E+10 | 0.400299E+09 | 0.112632E+10 | 0.655170E+09 | 0.471148E+09 | 0.00 | 0.00 |
| October | 0.120079E+10 | 0.605908E+09 | 0.109860E+10 | 0.711916E+09 | 0.386683E+09 | 0.00 | 0.00 |
| November | 0.875226E+09 | 0.765845E+09 | 0.906820E+09 | 0.615581E+09 | 0.291238E+09 | 0.00 | 0.00 |
| December | 0.657365E+09 | 0.108991E+10 | 0.780713E+09 | 0.526778E+09 | 0.253935E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.132475E+11 | 0.773522E+10 | 0.121867E+11 | 0.660042E+10 | 0.558630E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.657365E+09 | 0.251295E+09 | 0.780713E+09 | 0.388097E+09 | 0.253935E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.154080E+10 | 0.128563E+10 | 0.115288E+10 | 0.711916E+09 | 0.653997E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 41937670.62 | 0.143044E+10 | 0.233749E+09 | 55002115.31 | 0.178747E+09 | 0.00 | 0.00 |
| February | 0.159716E+09 | 0.933867E+09 | 0.332625E+09 | 0.101978E+09 | 0.230648E+09 | 0.00 | 0.00 |
| March | 0.314416E+09 | 0.833962E+09 | 0.520094E+09 | 0.108181E+09 | 0.411913E+09 | 0.00 | 0.00 |
| April | 0.508524E+09 | 0.562321E+09 | 0.621056E+09 | 0.165953E+09 | 0.455103E+09 | 0.00 | 0.00 |
| May | 0.775409E+09 | 0.445546E+09 | 0.812315E+09 | 0.236364E+09 | 0.575950E+09 | 0.00 | 0.00 |
| June | 0.987335E+09 | 0.280080E+09 | 0.879667E+09 | 0.272794E+09 | 0.606873E+09 | 0.00 | 0.00 |
| July | 0.113389E+10 | 0.230612E+09 | 0.888121E+09 | 0.300761E+09 | 0.587360E+09 | 0.00 | 0.00 |
| August | 0.897878E+09 | 0.268067E+09 | 0.739410E+09 | 0.230019E+09 | 0.509391E+09 | 0.00 | 0.00 |
| September | 0.598241E+09 | 0.388810E+09 | 0.558336E+09 | 0.176757E+09 | 0.381579E+09 | 0.00 | 0.00 |
| October | 0.327197E+09 | 0.593917E+09 | 0.415887E+09 | 0.128549E+09 | 0.287338E+09 | 0.00 | 0.00 |
| November | 0.137892E+09 | 0.818907E+09 | 0.280315E+09 | 87739504.81 | 0.192575E+09 | 0.00 | 0.00 |
| December | 41496017.13 | 0.121193E+10 | 0.205054E+09 | 51652699.56 | 0.153401E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.592393E+10 | 0.799846E+10 | 0.648663E+10 | 0.191575E+10 | 0.457088E+10 | 0.00 | 0.00 |
| Minimum of Months | 41496017.13 | 0.230612E+09 | 0.205054E+09 | 51652699.56 | 0.153401E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.113389E+10 | 0.143044E+10 | 0.888121E+09 | 0.300761E+09 | 0.606873E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.684541E+09 | 0.127231E+10 | 0.841605E+09 | 0.562724E+09 | 0.278881E+09 | 0.00 | 0.00 |
| February | 0.952858E+09 | 0.851089E+09 | 0.100610E+10 | 0.676469E+09 | 0.329627E+09 | 0.00 | 0.00 |
| March | 0.104703E+10 | 0.814017E+09 | 0.109040E+10 | 0.561097E+09 | 0.529306E+09 | 0.00 | 0.00 |
| April | 0.103610E+10 | 0.565212E+09 | 0.101401E+10 | 0.499188E+09 | 0.514824E+09 | 0.00 | 0.00 |
| May | 0.106978E+10 | 0.454922E+09 | 0.100772E+10 | 0.386911E+09 | 0.620813E+09 | 0.00 | 0.00 |
| June | 0.132186E+10 | 0.289677E+09 | 0.109411E+10 | 0.442580E+09 | 0.651531E+09 | 0.00 | 0.00 |
| July | 0.161398E+10 | 0.231083E+09 | 0.120564E+10 | 0.564943E+09 | 0.640696E+09 | 0.00 | 0.00 |
| August | 0.159644E+10 | 0.266658E+09 | 0.122421E+10 | 0.638133E+09 | 0.586078E+09 | 0.00 | 0.00 |
| September | 0.137261E+10 | 0.386413E+09 | 0.113255E+10 | 0.661924E+09 | 0.470629E+09 | 0.00 | 0.00 |
| October | 0.120129E+10 | 0.598410E+09 | 0.110174E+10 | 0.715282E+09 | 0.386458E+09 | 0.00 | 0.00 |
| November | 0.851665E+09 | 0.756631E+09 | 0.891493E+09 | 0.603226E+09 | 0.288266E+09 | 0.00 | 0.00 |
| December | 0.660003E+09 | 0.108187E+10 | 0.781475E+09 | 0.528186E+09 | 0.253289E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.134082E+11 | 0.756829E+10 | 0.123911E+11 | 0.684066E+10 | 0.555040E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.660003E+09 | 0.231083E+09 | 0.781475E+09 | 0.386911E+09 | 0.253289E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.161398E+10 | 0.127231E+10 | 0.122421E+10 | 0.715282E+09 | 0.651531E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 39849920.43 | 0.139553E+10 | 0.247957E+09 | 69004258.54 | 0.178953E+09 | 0.00 | 0.00 |
| February | 0.147140E+09 | 0.911842E+09 | 0.336264E+09 | 0.104982E+09 | 0.231283E+09 | 0.00 | 0.00 |
| March | 0.323270E+09 | 0.807704E+09 | 0.538576E+09 | 0.129653E+09 | 0.408923E+09 | 0.00 | 0.00 |
| April | 0.508599E+09 | 0.542421E+09 | 0.635684E+09 | 0.193363E+09 | 0.442321E+09 | 0.00 | 0.00 |
| May | 0.722909E+09 | 0.435493E+09 | 0.778110E+09 | 0.215940E+09 | 0.562170E+09 | 0.00 | 0.00 |
| June | 0.105255E+10 | 0.273925E+09 | 0.931684E+09 | 0.327277E+09 | 0.604407E+09 | 0.00 | 0.00 |
| July | 0.122352E+10 | 0.226940E+09 | 0.957544E+09 | 0.371917E+09 | 0.585627E+09 | 0.00 | 0.00 |
| August | 0.982771E+09 | 0.259209E+09 | 0.810745E+09 | 0.299983E+09 | 0.510762E+09 | 0.00 | 0.00 |
| September | 0.589580E+09 | 0.371078E+09 | 0.564571E+09 | 0.183511E+09 | 0.381060E+09 | 0.00 | 0.00 |
| October | 0.312710E+09 | 0.570916E+09 | 0.419027E+09 | 0.131915E+09 | 0.287112E+09 | 0.00 | 0.00 |
| November | 0.102217E+09 | 0.797218E+09 | 0.264988E+09 | 75384451.24 | 0.189603E+09 | 0.00 | 0.00 |
| December | 27222857.62 | 0.118723E+10 | 0.205815E+09 | 53060374.77 | 0.152755E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.603234E+10 | 0.777950E+10 | 0.669097E+10 | 0.215599E+10 | 0.453498E+10 | 0.00 | 0.00 |
| Minimum of Months | 27222857.62 | 0.226940E+09 | 0.205815E+09 | 53060374.77 | 0.152755E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.122352E+10 | 0.139553E+10 | 0.957544E+09 | 0.371917E+09 | 0.604407E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 1802995.65 | 0.907880E+09 | 98341482.54 | 0.00 | 98341482.54 | 0.00 | 0.00 |
| February | 19569860.02 | 0.598263E+09 | 0.125415E+09 | 0.00 | 0.125415E+09 | 0.00 | 0.00 |
| March | 80979205.61 | 0.519471E+09 | 0.225586E+09 | 11702.76 | 0.225574E+09 | 0.00 | 0.00 |
| April | 0.139820E+09 | 0.346449E+09 | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.00 | 0.00 |
| May | 0.262025E+09 | 0.268400E+09 | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.00 | 0.00 |
| June | 0.392725E+09 | 0.166818E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
| July | 0.446108E+09 | 0.136840E+09 | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.00 | 0.00 |
| August | 0.328146E+09 | 0.160266E+09 | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.00 | 0.00 |
| September | 0.186440E+09 | 0.240813E+09 | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.00 | 0.00 |
| October | 73958100.52 | 0.375672E+09 | 0.157280E+09 | 0.00 | 0.157280E+09 | 0.00 | 0.00 |
| November | 18184198.85 | 0.528117E+09 | 0.103471E+09 | 0.00 | 0.103471E+09 | 0.00 | 0.00 |
| December | 1386625.04 | 0.773676E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195115E+10 | 0.502266E+10 | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.00 | 0.00 |
| Minimum of Months | 1386625.04 | 0.136840E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Maximum of Months | 0.446108E+09 | 0.907880E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 1800312.55 | 0.907913E+09 | 98341482.54 | 0.00 | 98341482.54 | 0.00 | 0.00 |
| February | 19541784.08 | 0.598249E+09 | 0.125415E+09 | 0.00 | 0.125415E+09 | 0.00 | 0.00 |
| March | 80925411.92 | 0.519451E+09 | 0.225586E+09 | 11702.76 | 0.225574E+09 | 0.00 | 0.00 |
| April | 0.139587E+09 | 0.346621E+09 | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.00 | 0.00 |
| May | 0.261881E+09 | 0.268342E+09 | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.00 | 0.00 |
| June | 0.392620E+09 | 0.166794E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
| July | 0.446033E+09 | 0.136815E+09 | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.00 | 0.00 |
| August | 0.328041E+09 | 0.160282E+09 | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.00 | 0.00 |
| September | 0.186291E+09 | 0.240888E+09 | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.00 | 0.00 |
| October | 73870298.34 | 0.375672E+09 | 0.157280E+09 | 0.00 | 0.157280E+09 | 0.00 | 0.00 |
| November | 18177863.37 | 0.528062E+09 | 0.103471E+09 | 0.00 | 0.103471E+09 | 0.00 | 0.00 |
| December | 1385381.93 | 0.773677E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195015E+10 | 0.502277E+10 | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.00 | 0.00 |
| Minimum of Months | 1385381.93 | 0.136815E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Maximum of Months | 0.446033E+09 | 0.907913E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.643138E+09 | 0.775480E+09 | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.00 | 0.00 |
| February | 0.820343E+09 | 0.521809E+09 | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.00 | 0.00 |
| March | 0.799773E+09 | 0.510078E+09 | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.00 | 0.00 |
| April | 0.675198E+09 | 0.367404E+09 | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.00 | 0.00 |
| May | 0.622553E+09 | 0.295173E+09 | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.00 | 0.00 |
| June | 0.675505E+09 | 0.194022E+09 | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.00 | 0.00 |
| July | 0.849418E+09 | 0.150985E+09 | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.00 | 0.00 |
| August | 0.952689E+09 | 0.173596E+09 | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.00 | 0.00 |
| September | 0.972676E+09 | 0.247532E+09 | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.00 | 0.00 |
| October | 0.960060E+09 | 0.376122E+09 | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.00 | 0.00 |
| November | 0.760072E+09 | 0.470817E+09 | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.00 | 0.00 |
| December | 0.630648E+09 | 0.659054E+09 | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.936207E+10 | 0.474207E+10 | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.622553E+09 | 0.150985E+09 | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.972676E+09 | 0.775480E+09 | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.643097E+09 | 0.775517E+09 | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.00 | 0.00 |
| February | 0.820280E+09 | 0.521799E+09 | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.00 | 0.00 |
| March | 0.799615E+09 | 0.510154E+09 | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.00 | 0.00 |
| April | 0.675030E+09 | 0.367489E+09 | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.00 | 0.00 |
| May | 0.622449E+09 | 0.295067E+09 | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.00 | 0.00 |
| June | 0.675417E+09 | 0.193987E+09 | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.00 | 0.00 |
| July | 0.849348E+09 | 0.150959E+09 | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.00 | 0.00 |
| August | 0.952611E+09 | 0.173594E+09 | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.00 | 0.00 |
| September | 0.972588E+09 | 0.247549E+09 | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.00 | 0.00 |
| October | 0.959985E+09 | 0.376109E+09 | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.00 | 0.00 |
| November | 0.760028E+09 | 0.470770E+09 | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.00 | 0.00 |
| December | 0.630626E+09 | 0.659041E+09 | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.936108E+10 | 0.474203E+10 | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.622449E+09 | 0.150959E+09 | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.972588E+09 | 0.775517E+09 | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.665738E+09 | 0.125060E+10 | 0.827397E+09 | 0.548722E+09 | 0.278675E+09 | 0.00 | 0.00 |
| February | 0.949830E+09 | 0.831741E+09 | 0.100246E+10 | 0.673465E+09 | 0.328992E+09 | 0.00 | 0.00 |
| March | 0.102199E+10 | 0.796965E+09 | 0.107192E+10 | 0.539625E+09 | 0.532296E+09 | 0.00 | 0.00 |
| April | 0.103377E+10 | 0.549678E+09 | 0.999385E+09 | 0.471778E+09 | 0.527606E+09 | 0.00 | 0.00 |
| May | 0.112515E+10 | 0.444737E+09 | 0.104193E+10 | 0.407335E+09 | 0.634593E+09 | 0.00 | 0.00 |
| June | 0.126909E+10 | 0.285552E+09 | 0.104209E+10 | 0.388097E+09 | 0.653997E+09 | 0.00 | 0.00 |
| July | 0.153006E+10 | 0.237375E+09 | 0.113622E+10 | 0.493787E+09 | 0.642429E+09 | 0.00 | 0.00 |
| August | 0.151149E+10 | 0.264951E+09 | 0.115288E+10 | 0.568170E+09 | 0.584706E+09 | 0.00 | 0.00 |
| September | 0.137446E+10 | 0.369966E+09 | 0.112632E+10 | 0.655170E+09 | 0.471148E+09 | 0.00 | 0.00 |
| October | 0.120940E+10 | 0.556907E+09 | 0.109860E+10 | 0.711916E+09 | 0.386683E+09 | 0.00 | 0.00 |
| November | 0.879118E+09 | 0.731178E+09 | 0.906820E+09 | 0.615581E+09 | 0.291238E+09 | 0.00 | 0.00 |
| December | 0.659034E+09 | 0.105723E+10 | 0.780713E+09 | 0.526778E+09 | 0.253935E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.132291E+11 | 0.737688E+10 | 0.121867E+11 | 0.660042E+10 | 0.558630E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.659034E+09 | 0.237375E+09 | 0.780713E+09 | 0.388097E+09 | 0.253935E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.153006E+10 | 0.125060E+10 | 0.115288E+10 | 0.711916E+09 | 0.653997E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 43083004.83 | 0.139401E+10 | 0.233749E+09 | 55002115.31 | 0.178747E+09 | 0.00 | 0.00 |
| February | 0.160937E+09 | 0.907349E+09 | 0.332625E+09 | 0.101978E+09 | 0.230648E+09 | 0.00 | 0.00 |
| March | 0.315197E+09 | 0.807839E+09 | 0.520094E+09 | 0.108181E+09 | 0.411913E+09 | 0.00 | 0.00 |
| April | 0.508697E+09 | 0.538146E+09 | 0.621056E+09 | 0.165953E+09 | 0.455103E+09 | 0.00 | 0.00 |
| May | 0.775069E+09 | 0.423156E+09 | 0.812315E+09 | 0.236364E+09 | 0.575950E+09 | 0.00 | 0.00 |
| June | 0.992311E+09 | 0.260219E+09 | 0.879667E+09 | 0.272794E+09 | 0.606873E+09 | 0.00 | 0.00 |
| July | 0.112859E+10 | 0.220060E+09 | 0.888121E+09 | 0.300761E+09 | 0.587360E+09 | 0.00 | 0.00 |
| August | 0.896498E+09 | 0.250346E+09 | 0.739410E+09 | 0.230019E+09 | 0.509391E+09 | 0.00 | 0.00 |
| September | 0.600674E+09 | 0.362948E+09 | 0.558336E+09 | 0.176757E+09 | 0.381579E+09 | 0.00 | 0.00 |
| October | 0.335426E+09 | 0.557396E+09 | 0.415887E+09 | 0.128549E+09 | 0.287338E+09 | 0.00 | 0.00 |
| November | 0.140633E+09 | 0.789651E+09 | 0.280315E+09 | 87739504.81 | 0.192575E+09 | 0.00 | 0.00 |
| December | 42779462.83 | 0.117692E+10 | 0.205054E+09 | 51652699.56 | 0.153401E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.593990E+10 | 0.768803E+10 | 0.648663E+10 | 0.191575E+10 | 0.457088E+10 | 0.00 | 0.00 |
| Minimum of Months | 42779462.83 | 0.220060E+09 | 0.205054E+09 | 51652699.56 | 0.153401E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.112859E+10 | 0.139401E+10 | 0.888121E+09 | 0.300761E+09 | 0.606873E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.685659E+09 | 0.123703E+10 | 0.841605E+09 | 0.562724E+09 | 0.278881E+09 | 0.00 | 0.00 |
| February | 0.950863E+09 | 0.823587E+09 | 0.100610E+10 | 0.676469E+09 | 0.329627E+09 | 0.00 | 0.00 |
| March | 0.104282E+10 | 0.783965E+09 | 0.109040E+10 | 0.561097E+09 | 0.529306E+09 | 0.00 | 0.00 |
| April | 0.103626E+10 | 0.531995E+09 | 0.101401E+10 | 0.499188E+09 | 0.514824E+09 | 0.00 | 0.00 |
| May | 0.106661E+10 | 0.429622E+09 | 0.100772E+10 | 0.386911E+09 | 0.620813E+09 | 0.00 | 0.00 |
| June | 0.132024E+10 | 0.268511E+09 | 0.109411E+10 | 0.442580E+09 | 0.651531E+09 | 0.00 | 0.00 |
| July | 0.160256E+10 | 0.219162E+09 | 0.120564E+10 | 0.564943E+09 | 0.640696E+09 | 0.00 | 0.00 |
| August | 0.158821E+10 | 0.249990E+09 | 0.122421E+10 | 0.638133E+09 | 0.586078E+09 | 0.00 | 0.00 |
| September | 0.137098E+10 | 0.357528E+09 | 0.113255E+10 | 0.661924E+09 | 0.470629E+09 | 0.00 | 0.00 |
| October | 0.120926E+10 | 0.550092E+09 | 0.110174E+10 | 0.715282E+09 | 0.386458E+09 | 0.00 | 0.00 |
| November | 0.856022E+09 | 0.721454E+09 | 0.891493E+09 | 0.603226E+09 | 0.288266E+09 | 0.00 | 0.00 |
| December | 0.661775E+09 | 0.104891E+10 | 0.781475E+09 | 0.528186E+09 | 0.253289E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.133913E+11 | 0.722185E+10 | 0.123911E+11 | 0.684066E+10 | 0.555040E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.661775E+09 | 0.219162E+09 | 0.781475E+09 | 0.386911E+09 | 0.253289E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.160256E+10 | 0.123703E+10 | 0.122421E+10 | 0.715282E+09 | 0.651531E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 41780279.04 | 0.135923E+10 | 0.247957E+09 | 69004258.54 | 0.178953E+09 | 0.00 | 0.00 |
| February | 0.149930E+09 | 0.886430E+09 | 0.336264E+09 | 0.104982E+09 | 0.231283E+09 | 0.00 | 0.00 |
| March | 0.325807E+09 | 0.782575E+09 | 0.538576E+09 | 0.129653E+09 | 0.408923E+09 | 0.00 | 0.00 |
| April | 0.509080E+09 | 0.518334E+09 | 0.635684E+09 | 0.193363E+09 | 0.442321E+09 | 0.00 | 0.00 |
| May | 0.721479E+09 | 0.412995E+09 | 0.778110E+09 | 0.215940E+09 | 0.562170E+09 | 0.00 | 0.00 |
| June | 0.105372E+10 | 0.254297E+09 | 0.931684E+09 | 0.327277E+09 | 0.604407E+09 | 0.00 | 0.00 |
| July | 0.121502E+10 | 0.215676E+09 | 0.957544E+09 | 0.371917E+09 | 0.585627E+09 | 0.00 | 0.00 |
| August | 0.979639E+09 | 0.242936E+09 | 0.810745E+09 | 0.299983E+09 | 0.510762E+09 | 0.00 | 0.00 |
| September | 0.592990E+09 | 0.346414E+09 | 0.564571E+09 | 0.183511E+09 | 0.381060E+09 | 0.00 | 0.00 |
| October | 0.323269E+09 | 0.535313E+09 | 0.419027E+09 | 0.131915E+09 | 0.287112E+09 | 0.00 | 0.00 |
| November | 0.106344E+09 | 0.768973E+09 | 0.264988E+09 | 75384451.24 | 0.189603E+09 | 0.00 | 0.00 |
| December | 29340016.39 | 0.115271E+10 | 0.205815E+09 | 53060374.77 | 0.152755E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.604840E+10 | 0.747588E+10 | 0.669097E+10 | 0.215599E+10 | 0.453498E+10 | 0.00 | 0.00 |
| Minimum of Months | 29340016.39 | 0.215676E+09 | 0.205815E+09 | 53060374.77 | 0.152755E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.121502E+10 | 0.135923E+10 | 0.957544E+09 | 0.371917E+09 | 0.604407E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 2024236.89 | 0.886766E+09 | 98341482.54 | 0.00 | 98341482.54 | 0.00 | 0.00 |
| February | 20596859.64 | 0.582809E+09 | 0.125415E+09 | 0.00 | 0.125415E+09 | 0.00 | 0.00 |
| March | 82538942.22 | 0.504735E+09 | 0.225586E+09 | 11702.76 | 0.225574E+09 | 0.00 | 0.00 |
| April | 0.141643E+09 | 0.331889E+09 | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.00 | 0.00 |
| May | 0.263213E+09 | 0.256762E+09 | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.00 | 0.00 |
| June | 0.396510E+09 | 0.157027E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
| July | 0.443348E+09 | 0.132547E+09 | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.00 | 0.00 |
| August | 0.328155E+09 | 0.151918E+09 | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.00 | 0.00 |
| September | 0.189865E+09 | 0.224589E+09 | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.00 | 0.00 |
| October | 81345582.00 | 0.348941E+09 | 0.157280E+09 | 0.00 | 0.157280E+09 | 0.00 | 0.00 |
| November | 19648693.84 | 0.509272E+09 | 0.103471E+09 | 0.00 | 0.103471E+09 | 0.00 | 0.00 |
| December | 1651682.08 | 0.752942E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Annual Sum or Average | 0.197054E+10 | 0.484020E+10 | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.00 | 0.00 |
| Minimum of Months | 1651682.08 | 0.132547E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Maximum of Months | 0.443348E+09 | 0.886766E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 2017735.08 | 0.886789E+09 | 98341482.54 | 0.00 | 98341482.54 | 0.00 | 0.00 |
| February | 20533789.06 | 0.582748E+09 | 0.125415E+09 | 0.00 | 0.125415E+09 | 0.00 | 0.00 |
| March | 82413085.66 | 0.504640E+09 | 0.225586E+09 | 11702.76 | 0.225574E+09 | 0.00 | 0.00 |
| April | 0.141197E+09 | 0.331823E+09 | 0.249647E+09 | 1886348.25 | 0.247760E+09 | 0.00 | 0.00 |
| May | 0.262822E+09 | 0.256567E+09 | 0.337505E+09 | 19754104.49 | 0.317751E+09 | 0.00 | 0.00 |
| June | 0.396059E+09 | 0.156946E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
| July | 0.443093E+09 | 0.132442E+09 | 0.358798E+09 | 33165072.96 | 0.325633E+09 | 0.00 | 0.00 |
| August | 0.327817E+09 | 0.151861E+09 | 0.290904E+09 | 10495435.44 | 0.280409E+09 | 0.00 | 0.00 |
| September | 0.189541E+09 | 0.224499E+09 | 0.208874E+09 | 182323.39 | 0.208692E+09 | 0.00 | 0.00 |
| October | 81170132.84 | 0.348716E+09 | 0.157280E+09 | 0.00 | 0.157280E+09 | 0.00 | 0.00 |
| November | 19625578.09 | 0.509206E+09 | 0.103471E+09 | 0.00 | 0.103471E+09 | 0.00 | 0.00 |
| December | 1647895.75 | 0.752943E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Annual Sum or Average | 0.196794E+10 | 0.483918E+10 | 0.261843E+10 | 0.108916E+09 | 0.250951E+10 | 0.00 | 0.00 |
| Minimum of Months | 1647895.75 | 0.132442E+09 | 82464892.92 | 0.00 | 82464892.92 | 0.00 | 0.00 |
| Maximum of Months | 0.443093E+09 | 0.886789E+09 | 0.380142E+09 | 43421168.72 | 0.336721E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.643958E+09 | 0.754847E+09 | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.00 | 0.00 |
| February | 0.819827E+09 | 0.505439E+09 | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.00 | 0.00 |
| March | 0.798617E+09 | 0.491040E+09 | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.00 | 0.00 |
| April | 0.677271E+09 | 0.344496E+09 | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.00 | 0.00 |
| May | 0.621396E+09 | 0.280941E+09 | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.00 | 0.00 |
| June | 0.674889E+09 | 0.181210E+09 | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.00 | 0.00 |
| July | 0.843379E+09 | 0.144935E+09 | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.00 | 0.00 |
| August | 0.948198E+09 | 0.164556E+09 | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.00 | 0.00 |
| September | 0.972803E+09 | 0.229468E+09 | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.00 | 0.00 |
| October | 0.967022E+09 | 0.344523E+09 | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.00 | 0.00 |
| November | 0.765350E+09 | 0.445807E+09 | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.00 | 0.00 |
| December | 0.631885E+09 | 0.639988E+09 | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.936459E+10 | 0.452725E+10 | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.621396E+09 | 0.144935E+09 | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.972803E+09 | 0.754847E+09 | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.643890E+09 | 0.754838E+09 | 0.691989E+09 | 0.493720E+09 | 0.198269E+09 | 0.00 | 0.00 |
| February | 0.819688E+09 | 0.505356E+09 | 0.795247E+09 | 0.571488E+09 | 0.223759E+09 | 0.00 | 0.00 |
| March | 0.798370E+09 | 0.490964E+09 | 0.777412E+09 | 0.431456E+09 | 0.345957E+09 | 0.00 | 0.00 |
| April | 0.676926E+09 | 0.344394E+09 | 0.627975E+09 | 0.307711E+09 | 0.320263E+09 | 0.00 | 0.00 |
| May | 0.621046E+09 | 0.280702E+09 | 0.567118E+09 | 0.190725E+09 | 0.376393E+09 | 0.00 | 0.00 |
| June | 0.674511E+09 | 0.181081E+09 | 0.542569E+09 | 0.158724E+09 | 0.383845E+09 | 0.00 | 0.00 |
| July | 0.843128E+09 | 0.144820E+09 | 0.606893E+09 | 0.226191E+09 | 0.380702E+09 | 0.00 | 0.00 |
| August | 0.947944E+09 | 0.164477E+09 | 0.704371E+09 | 0.348646E+09 | 0.355725E+09 | 0.00 | 0.00 |
| September | 0.972567E+09 | 0.229384E+09 | 0.776856E+09 | 0.478595E+09 | 0.298261E+09 | 0.00 | 0.00 |
| October | 0.966787E+09 | 0.344440E+09 | 0.839993E+09 | 0.583367E+09 | 0.256625E+09 | 0.00 | 0.00 |
| November | 0.765249E+09 | 0.445659E+09 | 0.729976E+09 | 0.527842E+09 | 0.202135E+09 | 0.00 | 0.00 |
| December | 0.631825E+09 | 0.639952E+09 | 0.658124E+09 | 0.475125E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.936193E+10 | 0.452607E+10 | 0.831852E+10 | 0.479359E+10 | 0.352493E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.621046E+09 | 0.144820E+09 | 0.542569E+09 | 0.158724E+09 | 0.182999E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.972567E+09 | 0.754838E+09 | 0.839993E+09 | 0.583367E+09 | 0.383845E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 18600773.22 | 0.128368E+09 | 35900901.91 | 16557852.71 | 19343049.19 | 0.00 | 0.00 |
| February | 37638907.19 | 86277184.64 | 50594177.67 | 25190745.84 | 25403431.84 | 0.00 | 0.00 |
| March | 61576908.95 | 77495322.86 | 75103271.22 | 31107985.90 | 43995285.32 | 0.00 | 0.00 |
| April | 90844290.70 | 53883957.28 | 92631337.60 | 45945628.31 | 46685709.29 | 0.00 | 0.00 |
| May | 0.110191E+09 | 44513473.59 | 0.105725E+09 | 47075606.95 | 58649367.00 | 0.00 | 0.00 |
| June | 0.157212E+09 | 28757971.62 | 0.132345E+09 | 68112378.76 | 64232290.29 | 0.00 | 0.00 |
| July | 0.183518E+09 | 24259594.28 | 0.143672E+09 | 81284901.31 | 62386829.75 | 0.00 | 0.00 |
| August | 0.155257E+09 | 27249193.05 | 0.124738E+09 | 69463602.79 | 55274191.20 | 0.00 | 0.00 |
| September | 97316871.06 | 37460213.17 | 85350940.93 | 43990470.30 | 41360470.64 | 0.00 | 0.00 |
| October | 60291452.67 | 56426525.98 | 62807330.29 | 31653582.62 | 31153747.67 | 0.00 | 0.00 |
| November | 27133601.12 | 76593571.92 | 38756486.96 | 18088805.92 | 20667681.04 | 0.00 | 0.00 |
| December | 14507202.46 | 0.110135E+09 | 29598388.40 | 12732052.90 | 16866335.50 | 0.00 | 0.00 |
| Annual Sum or Average | 0.101409E+10 | 0.751421E+09 | 0.977222E+09 | 0.491204E+09 | 0.486018E+09 | 0.00 | 0.00 |
| Minimum of Months | 14507202.46 | 24259594.28 | 29598388.40 | 12732052.90 | 16866335.50 | 0.00 | 0.00 |
| Maximum of Months | 0.183518E+09 | 0.128368E+09 | 0.143672E+09 | 81284901.31 | 64232290.29 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 61098142.86 | 0.338014E+09 | 0.106922E+09 | 49313406.02 | 57608414.28 | 0.00 | 0.00 |
| February | 0.121206E+09 | 0.226180E+09 | 0.150682E+09 | 75024310.16 | 75657741.99 | 0.00 | 0.00 |
| March | 0.197700E+09 | 0.205621E+09 | 0.223676E+09 | 92647323.64 | 0.131029E+09 | 0.00 | 0.00 |
| April | 0.286490E+09 | 0.141430E+09 | 0.275879E+09 | 0.136838E+09 | 0.139042E+09 | 0.00 | 0.00 |
| May | 0.345515E+09 | 0.117167E+09 | 0.314875E+09 | 0.140203E+09 | 0.174672E+09 | 0.00 | 0.00 |
| June | 0.475368E+09 | 81944704.23 | 0.394155E+09 | 0.202856E+09 | 0.191300E+09 | 0.00 | 0.00 |
| July | 0.547657E+09 | 73689528.17 | 0.427890E+09 | 0.242087E+09 | 0.185804E+09 | 0.00 | 0.00 |
| August | 0.463825E+09 | 82677528.74 | 0.371500E+09 | 0.206880E+09 | 0.164620E+09 | 0.00 | 0.00 |
| September | 0.291486E+09 | 0.112395E+09 | 0.254196E+09 | 0.131015E+09 | 0.123182E+09 | 0.00 | 0.00 |
| October | 0.181531E+09 | 0.165200E+09 | 0.187056E+09 | 94272246.45 | 92783613.59 | 0.00 | 0.00 |
| November | 84488352.38 | 0.212440E+09 | 0.115426E+09 | 53872965.67 | 61553497.58 | 0.00 | 0.00 |
| December | 47421756.60 | 0.294282E+09 | 88151366.62 | 37919222.09 | 50232144.53 | 0.00 | 0.00 |
| Annual Sum or Average | 0.310379E+10 | 0.205104E+10 | 0.291041E+10 | 0.146293E+10 | 0.144748E+10 | 0.00 | 0.00 |
| Minimum of Months | 47421756.60 | 73689528.17 | 88151366.62 | 37919222.09 | 50232144.53 | 0.00 | 0.00 |
| Maximum of Months | 0.547657E+09 | 0.338014E+09 | 0.427890E+09 | 0.242087E+09 | 0.191300E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 17661934.31 | 0.136664E+09 | 35900901.91 | 16557852.71 | 19343049.19 | 0.00 | 0.00 |
| February | 36388828.17 | 91692570.47 | 50594177.67 | 25190745.84 | 25403431.84 | 0.00 | 0.00 |
| March | 59742844.55 | 82538553.62 | 75103271.22 | 31107985.90 | 43995285.32 | 0.00 | 0.00 |
| April | 89023237.51 | 57954578.71 | 92631337.60 | 45945628.31 | 46685709.29 | 0.00 | 0.00 |
| May | 0.108650E+09 | 47207912.14 | 0.105725E+09 | 47075606.95 | 58649367.00 | 0.00 | 0.00 |
| June | 0.155631E+09 | 30454850.85 | 0.132345E+09 | 68112378.76 | 64232290.29 | 0.00 | 0.00 |
| July | 0.183310E+09 | 25084892.77 | 0.143672E+09 | 81284901.31 | 62386829.75 | 0.00 | 0.00 |
| August | 0.154526E+09 | 28634728.90 | 0.124738E+09 | 69463602.79 | 55274191.20 | 0.00 | 0.00 |
| September | 95773293.44 | 40377429.40 | 85350940.93 | 43990470.30 | 41360470.64 | 0.00 | 0.00 |
| October | 57657940.68 | 61861781.53 | 62807330.29 | 31653582.62 | 31153747.67 | 0.00 | 0.00 |
| November | 25599976.79 | 82626392.37 | 38756486.96 | 18088805.92 | 20667681.04 | 0.00 | 0.00 |
| December | 13604724.39 | 0.117646E+09 | 29598388.40 | 12732052.90 | 16866335.50 | 0.00 | 0.00 |
| Annual Sum or Average | 0.997571E+09 | 0.802744E+09 | 0.977222E+09 | 0.491204E+09 | 0.486018E+09 | 0.00 | 0.00 |
| Minimum of Months | 13604724.39 | 25084892.77 | 29598388.40 | 12732052.90 | 16866335.50 | 0.00 | 0.00 |
| Maximum of Months | 0.183310E+09 | 0.136664E+09 | 0.143672E+09 | 81284901.31 | 64232290.29 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | -8.8 | -10.9 | -16.1 | 5.70 | -23.3 | 32.48 | 106.19 | 0.00 |
| February | -2.2 | -5.0 | -9.9 | 6.21 | -16.1 | 41.31 | 158.25 | 0.00 |
| March | 0.30 | -2.9 | -8.4 | 5.38 | -12.8 | 78.62 | 145.02 | 0.00 |
| April | 6.67 | 2.34 | -2.9 | 4.89 | -6.2 | 82.10 | 182.32 | 0.01 |
| May | 10.10 | 5.18 | 0.22 | 5.28 | -1.1 | 102.67 | 205.47 | 0.01 |
| June | 16.46 | 10.06 | 4.91 | 4.56 | 5.05 | 103.05 | 264.47 | 0.02 |
| July | 20.57 | 12.46 | 6.56 | 4.24 | 8.00 | 89.47 | 301.47 | 0.00 |
| August | 19.17 | 11.04 | 4.61 | 4.29 | 7.19 | 78.96 | 261.05 | 0.00 |
| September | 14.69 | 9.08 | 4.37 | 5.43 | 3.42 | 63.03 | 204.21 | 0.00 |
| October | 8.64 | 4.13 | -1.0 | 5.38 | -4.2 | 47.64 | 162.42 | 0.00 |
| November | 2.84 | -0.9 | -6.9 | 5.91 | -11.0 | 33.00 | 125.52 | 0.00 |
| December | -4.1 | -6.5 | -11.1 | 5.64 | -18.2 | 26.54 | 97.81 | 0.00 |
| Annual Sum or Average | 7.07 | 2.37 | -2.9 | 5.23 | -5.7 | 65.04 | 184.63 | 0.00 |
| Minimum of Months | -8.8 | -10.9 | -16.1 | 4.24 | -23.3 | 26.54 | 97.81 | 0.00 |
| Maximum of Months | 20.57 | 12.46 | 6.56 | 6.21 | 8.00 | 103.05 | 301.47 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 10.60 | 14-JAN-12:00 | 5.16 | -1.1 | 8.20 | -2.3 | 105.00 | 464.50 |
| February | 18.90 | 27-FEB-14:00 | 7.23 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
| March | 15.00 | 14-MAR-13:20 | 6.67 | -2.4 | 9.30 | 1.23 | 201.67 | 711.67 |
| April | 23.30 | 07-APR-13:00 | 9.68 | -4.4 | 9.30 | 4.92 | 314.50 | 110.00 |
| May | 30.00 | 20-MAY-15:00 | 15.22 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
| June | 32.20 | 29-JUN-12:00 | 14.40 | 0.60 | 9.30 | 17.03 | 187.00 | 729.00 |
| July | 37.20 | 17-JUL-15:00 | 17.28 | 4.40 | 4.60 | 20.22 | 119.50 | 797.00 |
| August | 35.60 | 05-AUG-15:00 | 17.65 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
| September | 34.40 | 02-SEP-14:00 | 16.28 | 4.40 | 7.70 | 20.75 | 95.50 | 789.50 |
| October | 25.00 | 18-OCT-13:00 | 11.40 | -1.1 | 7.70 | 7.35 | 48.00 | 913.00 |
| November | 17.20 | 04-NOV-13:00 | 8.18 | -1.1 | 11.30 | 2.22 | 81.00 | 689.50 |
| December | 13.90 | 10-DEC-01:00 | 5.50 | -5.0 | 13.90 | 5.74 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 10.60 | 5.16 | -7.8 | 4.60 | -2.3 | 0.00 | 0.00 | |
| Maximum of Months | 37.20 | 17.65 | 6.70 | 13.90 | 22.47 | 314.50 | 913.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -33.9 | 10-JAN-21:00 | -34.1 | -37.8 | 3.10 | -54.3 | 0.00 | 0.00 |
| February | -25.0 | 01-FEB-03:00 | -25.2 | -27.8 | 2.10 | -45.6 | 0.00 | 0.00 |
| March | -23.3 | 04-MAR-23:00 | -23.8 | -28.9 | 3.60 | -44.5 | 0.00 | 0.00 |
| April | -7.8 | 29-APR-03:00 | -8.7 | -10.6 | 4.10 | -25.6 | 0.00 | 0.00 |
| May | -2.8 | 08-MAY-00:10 | -3.3 | -3.9 | 6.18 | -10.2 | 0.00 | 0.00 |
| June | 0.60 | 15-JUN-03:00 | -0.5 | -1.7 | 2.60 | -15.7 | 0.00 | 0.00 |
| July | 5.60 | 08-JUL-03:00 | 2.99 | 0.00 | 4.10 | -9.2 | 0.00 | 0.00 |
| August | 6.70 | 17-AUG-00:00 | 4.32 | 1.70 | 2.60 | -7.1 | 0.00 | 0.00 |
| September | 0.00 | 17-SEP-02:00 | -1.6 | -3.9 | 4.10 | -16.8 | 0.00 | 0.00 |
| October | -6.1 | 10-OCT-05:19 | -6.6 | -7.8 | 3.77 | -20.6 | 0.00 | 0.00 |
| November | -16.7 | 26-NOV-07:00 | -17.3 | -20.6 | 4.60 | -33.8 | 19.50 | 94.00 |
| December | -28.3 | 29-DEC-08:00 | -28.6 | -32.2 | 2.10 | -48.7 | 69.50 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -33.9 | -34.1 | -37.8 | 2.10 | -54.3 | 0.00 | 0.00 | |
| Maximum of Months | 6.70 | 4.32 | 1.70 | 6.18 | -7.1 | 69.50 | 94.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 5.18 | 13-JAN-14:00 | 10.00 | 0.00 | 8.80 | -3.0 | 40.00 | 694.00 |
| February | 7.23 | 27-FEB-14:00 | 18.90 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
| March | 6.94 | 14-MAR-13:00 | 15.00 | -1.7 | 10.30 | 1.80 | 241.00 | 538.00 |
| April | 11.02 | 06-APR-15:00 | 22.20 | 1.10 | 3.60 | 5.33 | 110.00 | 779.00 |
| May | 15.22 | 20-MAY-15:00 | 30.00 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
| June | 19.20 | 20-JUN-14:00 | 29.40 | 14.40 | 2.60 | 18.28 | 204.00 | 614.00 |
| July | 19.21 | 19-JUL-11:00 | 29.40 | 14.40 | 8.80 | 19.52 | 306.50 | 563.50 |
| August | 17.65 | 05-AUG-15:00 | 35.60 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
| September | 20.12 | 07-SEP-15:20 | 25.17 | 17.93 | 4.10 | 15.88 | 127.67 | 652.00 |
| October | 11.61 | 18-OCT-14:00 | 25.00 | -0.6 | 7.70 | 7.55 | 40.50 | 852.00 |
| November | 8.89 | 17-NOV-16:00 | 17.20 | 1.10 | 11.30 | 4.10 | 0.00 | 0.00 |
| December | 7.62 | 19-DEC-14:00 | 12.80 | 2.80 | 8.20 | 1.37 | 74.00 | 138.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 5.18 | 10.00 | -7.8 | 2.60 | -3.0 | 0.00 | 0.00 | |
| Maximum of Months | 20.12 | 35.60 | 17.93 | 11.30 | 22.47 | 306.50 | 852.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 1.70 | 12-JAN-14:00 | 7.20 | 4.48 | 5.20 | -1.0 | 107.00 | 61.00 |
| February | -0.6 | 11-FEB-08:00 | 4.40 | 2.16 | 10.80 | -5.7 | 69.50 | 50.50 |
| March | -0.6 | 10-MAR-12:00 | 8.90 | 4.51 | 10.30 | -2.3 | 253.00 | 140.50 |
| April | 6.10 | 17-APR-16:19 | 7.97 | 6.96 | 4.50 | 0.87 | 201.50 | 117.50 |
| May | 12.20 | 02-MAY-12:00 | 18.90 | 14.61 | 12.90 | 14.84 | 108.50 | 934.50 |
| June | 15.60 | 20-JUN-19:00 | 25.60 | 18.76 | 3.60 | 20.22 | 17.50 | 17.00 |
| July | 16.70 | 18-JUL-21:00 | 19.40 | 17.51 | 4.10 | 16.49 | 0.00 | 0.00 |
| August | 11.10 | 08-AUG-11:00 | 26.70 | 16.75 | 2.60 | 12.03 | 134.50 | 869.00 |
| September | 18.30 | 07-SEP-14:00 | 24.40 | 20.10 | 4.10 | 15.57 | 111.00 | 720.00 |
| October | 6.70 | 01-OCT-14:09 | 9.08 | 7.78 | 2.10 | 4.07 | 260.33 | 0.33 |
| November | 3.30 | 16-NOV-19:00 | 10.60 | 6.88 | 9.80 | -1.7 | 0.00 | 0.00 |
| December | 2.80 | 19-DEC-14:09 | 10.97 | 6.81 | 10.78 | -1.0 | 95.00 | 292.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -0.6 | 4.40 | 2.16 | 2.10 | -5.7 | 0.00 | 0.00 | |
| Maximum of Months | 18.30 | 26.70 | 20.10 | 12.90 | 20.22 | 260.33 | 934.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 5.41 | 12.59 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 4.46 | 20.37 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 5.03 | 30.19 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 7.01 | 37.07 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 9.90 | 46.35 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 12.91 | 55.45 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 15.24 | 57.38 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 16.26 | 48.01 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 15.67 | 34.51 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 13.64 | 22.84 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 10.74 | 14.52 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 7.74 | 10.24 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 10.37 | 32.53 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 4.46 | 10.24 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 16.26 | 57.38 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134842E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186591437.7 | 59.44 | 0.00 | 0.00 |
| February | 0.123582E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168054555.2 | 59.44 | 0.00 | 0.00 |
| March | 0.135628E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186303721.9 | 59.44 | 0.00 | 0.00 |
| April | 0.127031E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179300242.7 | 59.44 | 0.00 | 0.00 |
| May | 0.124762E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182373221.3 | 59.44 | 0.00 | 0.00 |
| June | 0.113770E+10 | -968137512.5 | 0.00 | 0.00 | 720.00 | 0.00 | -169565191.1 | 59.44 | 0.00 | 0.00 |
| July | 0.112316E+10 | -950386573.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172775506.6 | 59.44 | 0.00 | 0.00 |
| August | 0.110152E+10 | -928451234.5 | 0.00 | 0.00 | 744.00 | 0.00 | -173066269.7 | 59.44 | 0.00 | 0.00 |
| September | 0.108087E+10 | -910798983.6 | 0.00 | 0.00 | 720.00 | 0.00 | -170076010.3 | 59.44 | 0.00 | 0.00 |
| October | 0.116387E+10 | -984709597.2 | 0.00 | 0.00 | 744.00 | 0.00 | -179162076.0 | 59.44 | 0.00 | 0.00 |
| November | 0.119237E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179015118.8 | 59.44 | 0.00 | 0.00 |
| December | 0.129833E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186596733.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145563E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213288E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108087E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186596733.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135628E+10 | -910798983.6 | 0.00 | 0.00 | 744.00 | 0.00 | -168054555.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| February | 0.123630E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168539977.5 | 59.44 | 0.00 | 0.00 |
| March | 0.135658E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599682.0 | 59.44 | 0.00 | 0.00 |
| April | 0.127136E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180342065.0 | 59.44 | 0.00 | 0.00 |
| May | 0.124891E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183662758.6 | 59.44 | 0.00 | 0.00 |
| June | 0.113850E+10 | -968138242.9 | 0.00 | 0.00 | 720.00 | 0.00 | -170365407.4 | 59.44 | 0.00 | 0.00 |
| July | 0.112329E+10 | -950387114.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172899024.0 | 59.44 | 0.00 | 0.00 |
| August | 0.110195E+10 | -928451400.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173501052.3 | 59.44 | 0.00 | 0.00 |
| September | 0.108311E+10 | -910797402.4 | 0.00 | 0.00 | 720.00 | 0.00 | -172317380.2 | 59.44 | 0.00 | 0.00 |
| October | 0.116881E+10 | -984708871.8 | 0.00 | 0.00 | 744.00 | 0.00 | -184104207.5 | 59.44 | 0.00 | 0.00 |
| November | 0.119387E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180515469.4 | 59.44 | 0.00 | 0.00 |
| December | 0.129834E+10 | -0.111174E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186600442.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145695E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214605E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108311E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135658E+10 | -910797402.4 | 0.00 | 0.00 | 744.00 | 0.00 | -168539977.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| February | 0.123630E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168543086.8 | 59.44 | 0.00 | 0.00 |
| March | 0.135658E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599719.1 | 59.44 | 0.00 | 0.00 |
| April | 0.127141E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180392531.4 | 59.44 | 0.00 | 0.00 |
| May | 0.124898E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183731826.3 | 59.44 | 0.00 | 0.00 |
| June | 0.113829E+10 | -968138388.5 | 0.00 | 0.00 | 720.00 | 0.00 | -170147080.1 | 59.44 | 0.00 | 0.00 |
| July | 0.112325E+10 | -950387334.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172860533.1 | 59.44 | 0.00 | 0.00 |
| August | 0.110174E+10 | -928450565.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173292439.2 | 59.44 | 0.00 | 0.00 |
| September | 0.108293E+10 | -910798200.8 | 0.00 | 0.00 | 720.00 | 0.00 | -172133253.5 | 59.44 | 0.00 | 0.00 |
| October | 0.116878E+10 | -984708153.5 | 0.00 | 0.00 | 744.00 | 0.00 | -184066853.3 | 59.44 | 0.00 | 0.00 |
| November | 0.119390E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180545218.7 | 59.44 | 0.00 | 0.00 |
| December | 0.129833E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604347.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145689E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214552E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108293E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135658E+10 | -910798200.8 | 0.00 | 0.00 | 744.00 | 0.00 | -168543086.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.1 | 59.44 | 0.00 | 0.00 |
| February | 0.123630E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168541889.3 | 59.44 | 0.00 | 0.00 |
| March | 0.135658E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599613.3 | 59.44 | 0.00 | 0.00 |
| April | 0.127140E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180386151.3 | 59.44 | 0.00 | 0.00 |
| May | 0.124876E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183509498.2 | 59.44 | 0.00 | 0.00 |
| June | 0.113756E+10 | -968137950.3 | 0.00 | 0.00 | 720.00 | 0.00 | -169420919.5 | 59.44 | 0.00 | 0.00 |
| July | 0.112309E+10 | -950385310.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172703734.4 | 59.44 | 0.00 | 0.00 |
| August | 0.110146E+10 | -928450392.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173008180.1 | 59.44 | 0.00 | 0.00 |
| September | 0.108234E+10 | -910797833.6 | 0.00 | 0.00 | 720.00 | 0.00 | -171543450.5 | 59.44 | 0.00 | 0.00 |
| October | 0.116795E+10 | -984708974.0 | 0.00 | 0.00 | 744.00 | 0.00 | -183237472.9 | 59.44 | 0.00 | 0.00 |
| November | 0.119378E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180421406.4 | 59.44 | 0.00 | 0.00 |
| December | 0.129833E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601805.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145660E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214258E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108234E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135658E+10 | -910797833.6 | 0.00 | 0.00 | 744.00 | 0.00 | -168541889.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.1 | 59.44 | 0.00 | 0.00 |
| February | 0.123630E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168541874.1 | 59.44 | 0.00 | 0.00 |
| March | 0.135658E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599602.4 | 59.44 | 0.00 | 0.00 |
| April | 0.127140E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180385005.3 | 59.44 | 0.00 | 0.00 |
| May | 0.124876E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183513553.4 | 59.44 | 0.00 | 0.00 |
| June | 0.113754E+10 | -968137820.4 | 0.00 | 0.00 | 720.00 | 0.00 | -169406396.0 | 59.44 | 0.00 | 0.00 |
| July | 0.112309E+10 | -950384146.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172703852.5 | 59.44 | 0.00 | 0.00 |
| August | 0.110144E+10 | -928450221.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172991806.3 | 59.44 | 0.00 | 0.00 |
| September | 0.108232E+10 | -910797405.5 | 0.00 | 0.00 | 720.00 | 0.00 | -171525949.0 | 59.44 | 0.00 | 0.00 |
| October | 0.116794E+10 | -984709188.6 | 0.00 | 0.00 | 744.00 | 0.00 | -183226329.9 | 59.44 | 0.00 | 0.00 |
| November | 0.119378E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180420963.1 | 59.44 | 0.00 | 0.00 |
| December | 0.129833E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601335.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145659E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214252E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108232E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135658E+10 | -910797405.5 | 0.00 | 0.00 | 744.00 | 0.00 | -168541874.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134833E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186503512.0 | 59.44 | 0.00 | 0.00 |
| February | 0.123551E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167746701.5 | 59.44 | 0.00 | 0.00 |
| March | 0.135602E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186044727.8 | 59.44 | 0.00 | 0.00 |
| April | 0.126982E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178802108.2 | 59.44 | 0.00 | 0.00 |
| May | 0.124709E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181840291.0 | 59.44 | 0.00 | 0.00 |
| June | 0.113671E+10 | -968137618.1 | 0.00 | 0.00 | 720.00 | 0.00 | -168572617.7 | 59.44 | 0.00 | 0.00 |
| July | 0.112300E+10 | -950384863.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172618488.7 | 59.44 | 0.00 | 0.00 |
| August | 0.110116E+10 | -928448887.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172712438.6 | 59.44 | 0.00 | 0.00 |
| September | 0.107969E+10 | -910798327.5 | 0.00 | 0.00 | 720.00 | 0.00 | -168893731.6 | 59.44 | 0.00 | 0.00 |
| October | 0.116194E+10 | -984707980.3 | 0.00 | 0.00 | 744.00 | 0.00 | -177227124.3 | 59.44 | 0.00 | 0.00 |
| November | 0.119079E+10 | -0.101335E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177431304.3 | 59.44 | 0.00 | 0.00 |
| December | 0.129826E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186529770.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145483E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212492E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.107969E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186529770.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135602E+10 | -910798327.5 | 0.00 | 0.00 | 744.00 | 0.00 | -167746701.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134836E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186534544.7 | 59.44 | 0.00 | 0.00 |
| February | 0.123560E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167833346.1 | 59.44 | 0.00 | 0.00 |
| March | 0.135609E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186105258.1 | 59.44 | 0.00 | 0.00 |
| April | 0.126986E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178842052.4 | 59.44 | 0.00 | 0.00 |
| May | 0.124697E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181723460.8 | 59.44 | 0.00 | 0.00 |
| June | 0.113650E+10 | -968137834.4 | 0.00 | 0.00 | 720.00 | 0.00 | -168359991.9 | 59.44 | 0.00 | 0.00 |
| July | 0.112297E+10 | -950382157.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172586037.3 | 59.44 | 0.00 | 0.00 |
| August | 0.110110E+10 | -928449673.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172653488.3 | 59.44 | 0.00 | 0.00 |
| September | 0.107947E+10 | -910797483.6 | 0.00 | 0.00 | 720.00 | 0.00 | -168674456.2 | 59.44 | 0.00 | 0.00 |
| October | 0.116177E+10 | -984709252.2 | 0.00 | 0.00 | 744.00 | 0.00 | -177063841.0 | 59.44 | 0.00 | 0.00 |
| November | 0.119070E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177345547.3 | 59.44 | 0.00 | 0.00 |
| December | 0.129829E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186555283.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145477E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212428E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.107947E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186555283.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135609E+10 | -910797483.6 | 0.00 | 0.00 | 744.00 | 0.00 | -167833346.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.250999E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186329271.7 | 59.44 | 0.00 | 0.00 |
| February | 0.230256E+10 | -0.213552E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167040491.0 | 59.44 | 0.00 | 0.00 |
| March | 0.252462E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184655384.0 | 59.44 | 0.00 | 0.00 |
| April | 0.235692E+10 | -0.218204E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174887174.5 | 59.44 | 0.00 | 0.00 |
| May | 0.230866E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178160367.2 | 59.44 | 0.00 | 0.00 |
| June | 0.210398E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167704024.5 | 59.44 | 0.00 | 0.00 |
| July | 0.207336E+10 | -0.190077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172592917.2 | 59.44 | 0.00 | 0.00 |
| August | 0.202975E+10 | -0.185690E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172845365.7 | 59.44 | 0.00 | 0.00 |
| September | 0.199124E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169642058.3 | 59.44 | 0.00 | 0.00 |
| October | 0.214783E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178409567.3 | 59.44 | 0.00 | 0.00 |
| November | 0.220462E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177898767.5 | 59.44 | 0.00 | 0.00 |
| December | 0.240991E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186433879.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269635E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211660E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199124E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186433879.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252462E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167040491.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.251027E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186606340.3 | 59.44 | 0.00 | 0.00 |
| February | 0.230394E+10 | -0.213553E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168414566.9 | 59.44 | 0.00 | 0.00 |
| March | 0.252637E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186405144.4 | 59.44 | 0.00 | 0.00 |
| April | 0.235978E+10 | -0.218204E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177747338.0 | 59.44 | 0.00 | 0.00 |
| May | 0.230988E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179375026.7 | 59.44 | 0.00 | 0.00 |
| June | 0.210406E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167776628.5 | 59.44 | 0.00 | 0.00 |
| July | 0.207338E+10 | -0.190078E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172605420.3 | 59.44 | 0.00 | 0.00 |
| August | 0.202989E+10 | -0.185691E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172984758.8 | 59.44 | 0.00 | 0.00 |
| September | 0.199307E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -171470644.0 | 59.44 | 0.00 | 0.00 |
| October | 0.215227E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182851032.9 | 59.44 | 0.00 | 0.00 |
| November | 0.220709E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180371310.9 | 59.44 | 0.00 | 0.00 |
| December | 0.241008E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603137.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269801E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213321E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199307E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186606340.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252637E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167776628.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.250998E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186315039.0 | 59.44 | 0.00 | 0.00 |
| February | 0.230251E+10 | -0.213552E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166988954.1 | 59.44 | 0.00 | 0.00 |
| March | 0.252446E+10 | -0.233996E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184493414.5 | 59.44 | 0.00 | 0.00 |
| April | 0.235660E+10 | -0.218204E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174565335.3 | 59.44 | 0.00 | 0.00 |
| May | 0.230857E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178066658.2 | 59.44 | 0.00 | 0.00 |
| June | 0.210392E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167640653.9 | 59.44 | 0.00 | 0.00 |
| July | 0.207337E+10 | -0.190078E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172591626.9 | 59.44 | 0.00 | 0.00 |
| August | 0.202970E+10 | -0.185690E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172792172.9 | 59.44 | 0.00 | 0.00 |
| September | 0.199108E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169476659.6 | 59.44 | 0.00 | 0.00 |
| October | 0.214769E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178267426.9 | 59.44 | 0.00 | 0.00 |
| November | 0.220462E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177904138.9 | 59.44 | 0.00 | 0.00 |
| December | 0.240992E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186447227.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269624E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211555E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199108E+10 | -0.233996E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186447227.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252446E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166988954.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.251027E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186606340.2 | 59.44 | 0.00 | 0.00 |
| February | 0.230397E+10 | -0.213553E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168445691.2 | 59.44 | 0.00 | 0.00 |
| March | 0.252643E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186458188.4 | 59.44 | 0.00 | 0.00 |
| April | 0.235943E+10 | -0.218203E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177393491.5 | 59.44 | 0.00 | 0.00 |
| May | 0.230976E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179261806.1 | 59.44 | 0.00 | 0.00 |
| June | 0.210396E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167680253.5 | 59.44 | 0.00 | 0.00 |
| July | 0.207339E+10 | -0.190077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172622300.8 | 59.44 | 0.00 | 0.00 |
| August | 0.202980E+10 | -0.185691E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172890332.4 | 59.44 | 0.00 | 0.00 |
| September | 0.199282E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -171227545.6 | 59.44 | 0.00 | 0.00 |
| October | 0.215223E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182815910.9 | 59.44 | 0.00 | 0.00 |
| November | 0.220716E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180434615.6 | 59.44 | 0.00 | 0.00 |
| December | 0.241007E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604501.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269793E+11 | -0.248468E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213244E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199282E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186606340.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252643E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167680253.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.251027E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186606349.1 | 59.44 | 0.00 | 0.00 |
| February | 0.230394E+10 | -0.213553E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168413105.7 | 59.44 | 0.00 | 0.00 |
| March | 0.252638E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186413760.9 | 59.44 | 0.00 | 0.00 |
| April | 0.235944E+10 | -0.218203E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177410994.9 | 59.44 | 0.00 | 0.00 |
| May | 0.230965E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179155353.9 | 59.44 | 0.00 | 0.00 |
| June | 0.210365E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167363817.9 | 59.44 | 0.00 | 0.00 |
| July | 0.207331E+10 | -0.190077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172541230.4 | 59.44 | 0.00 | 0.00 |
| August | 0.202960E+10 | -0.185691E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172696622.5 | 59.44 | 0.00 | 0.00 |
| September | 0.199222E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170612268.1 | 59.44 | 0.00 | 0.00 |
| October | 0.215082E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181405457.8 | 59.44 | 0.00 | 0.00 |
| November | 0.220680E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180076914.5 | 59.44 | 0.00 | 0.00 |
| December | 0.241007E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603773.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269762E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212930E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199222E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186606349.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252638E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167363817.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.251027E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186606350.5 | 59.44 | 0.00 | 0.00 |
| February | 0.230394E+10 | -0.213553E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168412470.9 | 59.44 | 0.00 | 0.00 |
| March | 0.252638E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186412027.4 | 59.44 | 0.00 | 0.00 |
| April | 0.235939E+10 | -0.218203E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177359683.0 | 59.44 | 0.00 | 0.00 |
| May | 0.230964E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179137922.2 | 59.44 | 0.00 | 0.00 |
| June | 0.210364E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167359020.9 | 59.44 | 0.00 | 0.00 |
| July | 0.207332E+10 | -0.190077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172549719.8 | 59.44 | 0.00 | 0.00 |
| August | 0.202960E+10 | -0.185690E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172695250.7 | 59.44 | 0.00 | 0.00 |
| September | 0.199219E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170586276.3 | 59.44 | 0.00 | 0.00 |
| October | 0.215081E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181390730.0 | 59.44 | 0.00 | 0.00 |
| November | 0.220680E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180082580.8 | 59.44 | 0.00 | 0.00 |
| December | 0.241007E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603737.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269760E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212920E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199219E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186606350.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252638E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167359020.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.250950E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185841350.2 | 59.44 | 0.00 | 0.00 |
| February | 0.230182E+10 | -0.213553E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166290154.3 | 59.44 | 0.00 | 0.00 |
| March | 0.252344E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183472719.3 | 59.44 | 0.00 | 0.00 |
| April | 0.235540E+10 | -0.218204E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -173367222.4 | 59.44 | 0.00 | 0.00 |
| May | 0.230816E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177664248.7 | 59.44 | 0.00 | 0.00 |
| June | 0.210360E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167320782.5 | 59.44 | 0.00 | 0.00 |
| July | 0.207330E+10 | -0.190077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172534333.0 | 59.44 | 0.00 | 0.00 |
| August | 0.202953E+10 | -0.185691E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172623643.3 | 59.44 | 0.00 | 0.00 |
| September | 0.199014E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168542187.3 | 59.44 | 0.00 | 0.00 |
| October | 0.214580E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176375157.0 | 59.44 | 0.00 | 0.00 |
| November | 0.220253E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175814633.6 | 59.44 | 0.00 | 0.00 |
| December | 0.240946E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185990516.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269527E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210584E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199014E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -185990516.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252344E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166290154.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.250949E+10 | -0.232366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185835091.5 | 59.44 | 0.00 | 0.00 |
| February | 0.230181E+10 | -0.213553E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166284786.4 | 59.44 | 0.00 | 0.00 |
| March | 0.252341E+10 | -0.233997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183445016.9 | 59.44 | 0.00 | 0.00 |
| April | 0.235538E+10 | -0.218204E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -173341972.0 | 59.44 | 0.00 | 0.00 |
| May | 0.230816E+10 | -0.213050E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177664744.4 | 59.44 | 0.00 | 0.00 |
| June | 0.210360E+10 | -0.193628E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167321689.7 | 59.44 | 0.00 | 0.00 |
| July | 0.207331E+10 | -0.190077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172535298.0 | 59.44 | 0.00 | 0.00 |
| August | 0.202953E+10 | -0.185691E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172621461.9 | 59.44 | 0.00 | 0.00 |
| September | 0.199013E+10 | -0.182160E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168533532.8 | 59.44 | 0.00 | 0.00 |
| October | 0.214580E+10 | -0.196942E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176371533.2 | 59.44 | 0.00 | 0.00 |
| November | 0.220253E+10 | -0.202672E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175812215.1 | 59.44 | 0.00 | 0.00 |
| December | 0.240946E+10 | -0.222347E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185990624.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269526E+11 | -0.248469E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210576E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.199013E+10 | -0.233997E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -185990624.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.252341E+10 | -0.182160E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166284786.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134823E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186397071.7 | 59.44 | 0.00 | 0.00 |
| February | 0.123507E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167308730.8 | 59.44 | 0.00 | 0.00 |
| March | 0.135478E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184797756.7 | 59.44 | 0.00 | 0.00 |
| April | 0.126766E+10 | -0.109102E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176640298.5 | 59.44 | 0.00 | 0.00 |
| May | 0.124517E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179925362.9 | 59.44 | 0.00 | 0.00 |
| June | 0.113837E+10 | -968137949.8 | 0.00 | 0.00 | 720.00 | 0.00 | -170235988.3 | 59.44 | 0.00 | 0.00 |
| July | 0.112419E+10 | -950383812.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173803548.8 | 59.44 | 0.00 | 0.00 |
| August | 0.110292E+10 | -928449704.3 | 0.00 | 0.00 | 744.00 | 0.00 | -174471922.2 | 59.44 | 0.00 | 0.00 |
| September | 0.108278E+10 | -910798113.9 | 0.00 | 0.00 | 720.00 | 0.00 | -171986280.6 | 59.44 | 0.00 | 0.00 |
| October | 0.116683E+10 | -984709238.3 | 0.00 | 0.00 | 744.00 | 0.00 | -182118227.4 | 59.44 | 0.00 | 0.00 |
| November | 0.119240E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179040392.8 | 59.44 | 0.00 | 0.00 |
| December | 0.129822E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186486042.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145566E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213321E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108278E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186486042.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135478E+10 | -910798113.9 | 0.00 | 0.00 | 744.00 | 0.00 | -167308730.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.4 | 59.44 | 0.00 | 0.00 |
| February | 0.123617E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168411642.4 | 59.44 | 0.00 | 0.00 |
| March | 0.135634E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186356560.2 | 59.44 | 0.00 | 0.00 |
| April | 0.126933E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178318670.7 | 59.44 | 0.00 | 0.00 |
| May | 0.124608E+10 | -0.106524E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180833850.1 | 59.44 | 0.00 | 0.00 |
| June | 0.113848E+10 | -968136541.0 | 0.00 | 0.00 | 720.00 | 0.00 | -170346600.2 | 59.44 | 0.00 | 0.00 |
| July | 0.112421E+10 | -950383005.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173829284.4 | 59.44 | 0.00 | 0.00 |
| August | 0.110323E+10 | -928449613.8 | 0.00 | 0.00 | 744.00 | 0.00 | -174781739.4 | 59.44 | 0.00 | 0.00 |
| September | 0.108414E+10 | -910799647.9 | 0.00 | 0.00 | 720.00 | 0.00 | -173345105.3 | 59.44 | 0.00 | 0.00 |
| October | 0.116942E+10 | -984708845.4 | 0.00 | 0.00 | 744.00 | 0.00 | -184712971.9 | 59.44 | 0.00 | 0.00 |
| November | 0.119388E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180520568.5 | 59.44 | 0.00 | 0.00 |
| December | 0.129834E+10 | -0.111174E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186600238.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145681E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214466E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108414E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135634E+10 | -910799647.9 | 0.00 | 0.00 | 744.00 | 0.00 | -168411642.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134822E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186389749.0 | 59.44 | 0.00 | 0.00 |
| February | 0.123503E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167272611.8 | 59.44 | 0.00 | 0.00 |
| March | 0.135463E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184651072.9 | 59.44 | 0.00 | 0.00 |
| April | 0.126733E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176319786.6 | 59.44 | 0.00 | 0.00 |
| May | 0.124493E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179684439.2 | 59.44 | 0.00 | 0.00 |
| June | 0.113801E+10 | -968137336.2 | 0.00 | 0.00 | 720.00 | 0.00 | -169872126.2 | 59.44 | 0.00 | 0.00 |
| July | 0.112401E+10 | -950382777.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173630671.5 | 59.44 | 0.00 | 0.00 |
| August | 0.110268E+10 | -928450055.6 | 0.00 | 0.00 | 744.00 | 0.00 | -174231925.5 | 59.44 | 0.00 | 0.00 |
| September | 0.108254E+10 | -910798018.3 | 0.00 | 0.00 | 720.00 | 0.00 | -171741360.4 | 59.44 | 0.00 | 0.00 |
| October | 0.116660E+10 | -984709669.8 | 0.00 | 0.00 | 744.00 | 0.00 | -181894226.0 | 59.44 | 0.00 | 0.00 |
| November | 0.119247E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179107478.6 | 59.44 | 0.00 | 0.00 |
| December | 0.129823E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186498615.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145547E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213129E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108254E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186498615.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135463E+10 | -910798018.3 | 0.00 | 0.00 | 744.00 | 0.00 | -167272611.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.3 | 59.44 | 0.00 | 0.00 |
| February | 0.123624E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168476351.3 | 59.44 | 0.00 | 0.00 |
| March | 0.135645E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186468619.8 | 59.44 | 0.00 | 0.00 |
| April | 0.126901E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177996016.8 | 59.44 | 0.00 | 0.00 |
| May | 0.124584E+10 | -0.106524E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180592971.8 | 59.44 | 0.00 | 0.00 |
| June | 0.113804E+10 | -968137411.6 | 0.00 | 0.00 | 720.00 | 0.00 | -169905821.5 | 59.44 | 0.00 | 0.00 |
| July | 0.112406E+10 | -950385494.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173674381.9 | 59.44 | 0.00 | 0.00 |
| August | 0.110291E+10 | -928450909.6 | 0.00 | 0.00 | 744.00 | 0.00 | -174456390.7 | 59.44 | 0.00 | 0.00 |
| September | 0.108392E+10 | -910797998.5 | 0.00 | 0.00 | 720.00 | 0.00 | -173117136.0 | 59.44 | 0.00 | 0.00 |
| October | 0.116958E+10 | -984708975.5 | 0.00 | 0.00 | 744.00 | 0.00 | -184869868.8 | 59.44 | 0.00 | 0.00 |
| November | 0.119393E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180568440.9 | 59.44 | 0.00 | 0.00 |
| December | 0.129833E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603791.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145667E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214333E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108392E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135645E+10 | -910797998.5 | 0.00 | 0.00 | 744.00 | 0.00 | -168476351.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| February | 0.123624E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168481765.3 | 59.44 | 0.00 | 0.00 |
| March | 0.135645E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186469501.4 | 59.44 | 0.00 | 0.00 |
| April | 0.126939E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178376306.8 | 59.44 | 0.00 | 0.00 |
| May | 0.124579E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180548050.8 | 59.44 | 0.00 | 0.00 |
| June | 0.113774E+10 | -968137879.9 | 0.00 | 0.00 | 720.00 | 0.00 | -169598960.9 | 59.44 | 0.00 | 0.00 |
| July | 0.112374E+10 | -950384407.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173360155.5 | 59.44 | 0.00 | 0.00 |
| August | 0.110261E+10 | -928451708.0 | 0.00 | 0.00 | 744.00 | 0.00 | -174160332.0 | 59.44 | 0.00 | 0.00 |
| September | 0.108374E+10 | -910797079.6 | 0.00 | 0.00 | 720.00 | 0.00 | -172939693.6 | 59.44 | 0.00 | 0.00 |
| October | 0.116932E+10 | -984709166.9 | 0.00 | 0.00 | 744.00 | 0.00 | -184611912.7 | 59.44 | 0.00 | 0.00 |
| November | 0.119386E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180500079.7 | 59.44 | 0.00 | 0.00 |
| December | 0.129834E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601959.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145657E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214225E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108374E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135645E+10 | -910797079.6 | 0.00 | 0.00 | 744.00 | 0.00 | -168481765.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134843E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| February | 0.123624E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168482554.2 | 59.44 | 0.00 | 0.00 |
| March | 0.135645E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186470122.5 | 59.44 | 0.00 | 0.00 |
| April | 0.126934E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178332738.6 | 59.44 | 0.00 | 0.00 |
| May | 0.124577E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180521860.9 | 59.44 | 0.00 | 0.00 |
| June | 0.113771E+10 | -968137513.1 | 0.00 | 0.00 | 720.00 | 0.00 | -169567907.4 | 59.44 | 0.00 | 0.00 |
| July | 0.112374E+10 | -950383868.9 | 0.00 | 0.00 | 744.00 | 0.00 | -173358193.7 | 59.44 | 0.00 | 0.00 |
| August | 0.110260E+10 | -928450297.6 | 0.00 | 0.00 | 744.00 | 0.00 | -174144992.5 | 59.44 | 0.00 | 0.00 |
| September | 0.108371E+10 | -910797377.7 | 0.00 | 0.00 | 720.00 | 0.00 | -172916976.6 | 59.44 | 0.00 | 0.00 |
| October | 0.116933E+10 | -984709471.6 | 0.00 | 0.00 | 744.00 | 0.00 | -184619197.4 | 59.44 | 0.00 | 0.00 |
| November | 0.119386E+10 | -0.101335E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180502121.2 | 59.44 | 0.00 | 0.00 |
| December | 0.129834E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604466.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145655E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214213E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108371E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605027.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135645E+10 | -910797377.7 | 0.00 | 0.00 | 744.00 | 0.00 | -168482554.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134801E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186184112.6 | 59.44 | 0.00 | 0.00 |
| February | 0.123470E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166935817.7 | 59.44 | 0.00 | 0.00 |
| March | 0.135434E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184360501.5 | 59.44 | 0.00 | 0.00 |
| April | 0.126710E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176085907.7 | 59.44 | 0.00 | 0.00 |
| May | 0.124457E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179321945.0 | 59.44 | 0.00 | 0.00 |
| June | 0.113765E+10 | -968137795.4 | 0.00 | 0.00 | 720.00 | 0.00 | -169509277.7 | 59.44 | 0.00 | 0.00 |
| July | 0.112373E+10 | -950380937.7 | 0.00 | 0.00 | 744.00 | 0.00 | -173347336.3 | 59.44 | 0.00 | 0.00 |
| August | 0.110232E+10 | -928451299.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173868502.7 | 59.44 | 0.00 | 0.00 |
| September | 0.108198E+10 | -910797673.2 | 0.00 | 0.00 | 720.00 | 0.00 | -171181411.4 | 59.44 | 0.00 | 0.00 |
| October | 0.116571E+10 | -984709006.1 | 0.00 | 0.00 | 744.00 | 0.00 | -180999968.4 | 59.44 | 0.00 | 0.00 |
| November | 0.119173E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178367464.3 | 59.44 | 0.00 | 0.00 |
| December | 0.129799E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186254013.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145498E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212642E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108198E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186254013.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135434E+10 | -910797673.2 | 0.00 | 0.00 | 744.00 | 0.00 | -166935817.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.134801E+10 | -0.116183E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186181536.3 | 59.44 | 0.00 | 0.00 |
| February | 0.123469E+10 | -0.106776E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166932139.9 | 59.44 | 0.00 | 0.00 |
| March | 0.135433E+10 | -0.116998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184346042.5 | 59.44 | 0.00 | 0.00 |
| April | 0.126708E+10 | -0.109101E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176065250.3 | 59.44 | 0.00 | 0.00 |
| May | 0.124456E+10 | -0.106525E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179307642.5 | 59.44 | 0.00 | 0.00 |
| June | 0.113763E+10 | -968137012.4 | 0.00 | 0.00 | 720.00 | 0.00 | -169495283.3 | 59.44 | 0.00 | 0.00 |
| July | 0.112372E+10 | -950386217.8 | 0.00 | 0.00 | 744.00 | 0.00 | -173337266.2 | 59.44 | 0.00 | 0.00 |
| August | 0.110231E+10 | -928449099.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173862299.4 | 59.44 | 0.00 | 0.00 |
| September | 0.108197E+10 | -910799383.3 | 0.00 | 0.00 | 720.00 | 0.00 | -171169376.2 | 59.44 | 0.00 | 0.00 |
| October | 0.116570E+10 | -984707750.7 | 0.00 | 0.00 | 744.00 | 0.00 | -180988483.0 | 59.44 | 0.00 | 0.00 |
| November | 0.119173E+10 | -0.101336E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178371247.9 | 59.44 | 0.00 | 0.00 |
| December | 0.129798E+10 | -0.111173E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186252704.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145497E+11 | -0.124234E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212631E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.108197E+10 | -0.116998E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186252704.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.135433E+10 | -910799383.3 | 0.00 | 0.00 | 744.00 | 0.00 | -166932139.9 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 226.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 275.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 304.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 325.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 385.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 434.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 417.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 421.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 352.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 317.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 269.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 236.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 3965.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 226.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 434.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.452894E+10 | 3911.57 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.268665E+10 | 2944.04 | 04-FEB-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.237145E+10 | 2903.18 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.123342E+10 | 1841.55 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.689498E+09 | 1543.48 | 08-MAY-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 8777289.19 | 486.81 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 24208465.57 | 463.61 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.182875E+09 | 1141.04 | 10-OCT-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.124046E+10 | 2200.59 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.321502E+10 | 3458.96 | 31-DEC-08:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.161813E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.452894E+10 | 3911.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.543750E+10 | 3991.94 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.359128E+10 | 3107.70 | 04-FEB-08:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.323142E+10 | 3072.55 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.172213E+10 | 1908.90 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.874290E+09 | 1601.57 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 11212025.36 | 542.92 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.115102E+09 | 716.02 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.503552E+09 | 1291.58 | 10-OCT-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.205181E+10 | 2413.02 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.406058E+10 | 3577.29 | 31-DEC-08:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.215989E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.543750E+10 | 3991.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.292735E+10 | 10446.33 | 03-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.131797E+10 | 10446.33 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.818768E+09 | 10446.33 | 03-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.141606E+09 | 10446.33 | 03-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.137523E+09 | 10446.33 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 9526477.13 | 10446.33 | 10-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.381762E+09 | 10446.33 | 14-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.145231E+10 | 10446.33 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.718682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.292735E+10 | 10446.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.539900E+10 | 3988.06 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.357574E+10 | 3099.01 | 04-FEB-08:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.318688E+10 | 3080.56 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.167862E+10 | 1945.89 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.876328E+09 | 1593.79 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 11817733.70 | 568.39 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.102421E+09 | 722.07 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.493342E+09 | 1256.02 | 10-OCT-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.205756E+10 | 2408.80 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.405009E+10 | 3569.87 | 31-DEC-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.214318E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.539900E+10 | 3988.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.394418E+10 | 2989.10 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.257382E+10 | 2321.18 | 04-FEB-08:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.226198E+10 | 2252.61 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.112573E+10 | 1339.63 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.561749E+09 | 1073.56 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 468285.31 | 91.08 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 42512296.87 | 442.10 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.249262E+09 | 885.31 | 10-OCT-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137193E+10 | 1723.67 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.289241E+10 | 2710.00 | 31-DEC-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.150240E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.394418E+10 | 2989.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.394245E+10 | 2989.19 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.257322E+10 | 2321.35 | 04-FEB-08:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.226007E+10 | 2253.58 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.112431E+10 | 1341.22 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.562621E+09 | 1073.15 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 477263.16 | 92.12 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 41742470.19 | 441.49 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.249066E+09 | 884.67 | 10-OCT-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137256E+10 | 1723.47 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.289215E+10 | 2709.84 | 31-DEC-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.150187E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.394245E+10 | 2989.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.306137E+10 | 2907.96 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.171731E+10 | 2140.89 | 04-FEB-08:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.143641E+10 | 2055.90 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.686620E+09 | 1253.81 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.397618E+09 | 1035.85 | 09-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58150827.20 | 740.02 | 10-OCT-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.659906E+09 | 1508.40 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.207985E+10 | 2589.19 | 31-DEC-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.100972E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.306137E+10 | 2907.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.330157E+10 | 3034.14 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.188603E+10 | 2281.85 | 05-FEB-07:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.156948E+10 | 2193.93 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.731382E+09 | 1316.08 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.430062E+09 | 1133.62 | 09-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 59790010.80 | 778.57 | 10-OCT-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.719770E+09 | 1637.98 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.228751E+10 | 2757.58 | 31-DEC-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.109856E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.330157E+10 | 3034.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.748480E+10 | 7226.53 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.378805E+10 | 5300.89 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.255614E+10 | 5096.25 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.661306E+09 | 2867.15 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.541067E+09 | 2491.50 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 61992208.13 | 975.52 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.322322E+09 | 2357.31 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.216544E+10 | 4622.85 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.544329E+10 | 6282.39 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.748480E+10 | 7226.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.929426E+10 | 7352.35 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.542787E+10 | 5498.19 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.406672E+10 | 5324.55 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.112975E+10 | 2915.79 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.682997E+09 | 2582.70 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.177228E+09 | 1475.25 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.848045E+09 | 2507.76 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.370085E+10 | 5010.45 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.714326E+10 | 6451.34 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.324710E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.929426E+10 | 7352.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.740032E+10 | 7211.03 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.376410E+10 | 5300.22 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.247299E+10 | 5098.74 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.666263E+09 | 2919.18 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.551381E+09 | 2477.52 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 55145854.70 | 1002.71 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.311071E+09 | 2343.45 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.217126E+10 | 4611.63 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.541257E+10 | 6279.22 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.228051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.740032E+10 | 7211.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.921135E+10 | 7337.33 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.538557E+10 | 5495.94 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.396215E+10 | 5328.56 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.110277E+10 | 2968.94 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.690269E+09 | 2564.05 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.156145E+09 | 1483.21 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.821495E+09 | 2497.39 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.370634E+10 | 5006.34 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.711593E+10 | 6452.41 | 31-DEC-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.321520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.921135E+10 | 7337.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.624995E+10 | 5193.16 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.355169E+10 | 3863.94 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.252384E+10 | 3693.51 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.507737E+09 | 1978.08 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324966E+09 | 1648.88 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 37055198.90 | 722.55 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.331969E+09 | 1630.64 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.218602E+10 | 3366.02 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.465229E+10 | 4545.30 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.203655E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.624995E+10 | 5193.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.624631E+10 | 5193.33 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.355085E+10 | 3864.63 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.252147E+10 | 3695.84 | 05-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.505494E+09 | 1979.77 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.327197E+09 | 1647.01 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 36387025.44 | 724.44 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.332222E+09 | 1630.21 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.218782E+10 | 3366.45 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.465168E+10 | 4545.77 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.203594E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.624631E+10 | 5193.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.451385E+10 | 5060.45 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.207562E+10 | 3612.09 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117643E+10 | 3420.90 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.237701E+09 | 1902.47 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.217713E+09 | 1552.43 | 09-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 62774355.25 | 1346.01 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.978762E+09 | 3018.33 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.303247E+10 | 4354.89 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.122953E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.451385E+10 | 5060.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.451042E+10 | 5060.62 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.207555E+10 | 3613.05 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117363E+10 | 3422.56 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238030E+09 | 1905.31 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.218321E+09 | 1560.43 | 09-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 63449961.02 | 1343.53 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.980560E+09 | 3016.87 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.303203E+10 | 4355.38 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.122920E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.451042E+10 | 5060.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.612833E+10 | 5316.15 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.349752E+10 | 4103.39 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.290075E+10 | 4105.71 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.133967E+10 | 2598.15 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.897416E+09 | 2453.71 | 22-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.107663E+09 | 1309.88 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 5264845.67 | 464.81 | 09-JUL-05:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 54560798.38 | 1010.84 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.412222E+09 | 1530.51 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.997441E+09 | 2228.31 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.254125E+10 | 3782.44 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.475418E+10 | 4707.60 | 31-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.236363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 5264845.67 | 464.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.612833E+10 | 5316.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.707042E+10 | 5347.19 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.435370E+10 | 4128.35 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.356627E+10 | 4130.89 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.157896E+10 | 2602.93 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.970940E+09 | 2483.57 | 22-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 99985792.19 | 1299.17 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 4670851.14 | 391.34 | 09-JUL-03:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 56370365.10 | 1013.68 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.533907E+09 | 1574.51 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.145669E+10 | 2254.38 | 10-OCT-06:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.335972E+10 | 3855.21 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.565002E+10 | 4736.77 | 31-DEC-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.287016E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 4670851.14 | 391.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.707042E+10 | 5347.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.608193E+10 | 5300.27 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.347305E+10 | 4095.43 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.284332E+10 | 4096.62 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.131835E+10 | 2634.81 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.889047E+09 | 2452.34 | 22-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.100724E+09 | 1324.23 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 6268560.77 | 482.64 | 08-JUL-03:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 49681008.07 | 1011.70 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.392359E+09 | 1525.20 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.973956E+09 | 2223.21 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.253306E+10 | 3777.93 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.473362E+10 | 4695.35 | 31-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.233954E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 6268560.77 | 482.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.608193E+10 | 5300.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.702282E+10 | 5331.73 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.432650E+10 | 4120.57 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.349755E+10 | 4122.40 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.153624E+10 | 2638.80 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.961621E+09 | 2482.29 | 22-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 97004203.23 | 1313.05 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 6536046.18 | 509.82 | 08-JUL-03:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 50667719.70 | 1014.01 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.499398E+09 | 1570.65 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.141319E+10 | 2248.73 | 10-OCT-06:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.336340E+10 | 3848.84 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.563126E+10 | 4725.77 | 31-DEC-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.284062E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 6536046.18 | 509.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.702282E+10 | 5331.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.518015E+10 | 3990.42 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.315109E+10 | 3093.37 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.253359E+10 | 3089.33 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.104856E+10 | 1900.09 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.631805E+09 | 1585.12 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 39353297.65 | 872.20 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 21596852.98 | 619.20 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.301436E+09 | 1071.12 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.920058E+09 | 1603.27 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.235772E+10 | 2829.51 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.409358E+10 | 3531.28 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.202789E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.518015E+10 | 3990.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.517837E+10 | 3990.24 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.315111E+10 | 3093.38 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.253256E+10 | 3089.32 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.104747E+10 | 1903.20 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.633657E+09 | 1584.75 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 39496636.20 | 873.64 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 21296935.63 | 618.84 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.300487E+09 | 1070.93 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.920847E+09 | 1603.08 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.235895E+10 | 2829.35 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.409320E+10 | 3531.21 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.202774E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.517837E+10 | 3990.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.425732E+10 | 3955.96 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.232514E+10 | 3064.35 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.189224E+10 | 3058.67 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.823926E+09 | 1893.19 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.557884E+09 | 1552.07 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 41795830.44 | 882.08 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 20833851.04 | 615.66 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.207565E+09 | 1022.20 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.528943E+09 | 1574.57 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.159720E+10 | 2748.56 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.322239E+10 | 3495.29 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154752E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.425732E+10 | 3955.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.425559E+10 | 3955.76 | 10-JAN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.232531E+10 | 3064.37 | 04-FEB-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.189140E+10 | 3058.72 | 05-MAR-01:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.824571E+09 | 1896.28 | 29-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.559723E+09 | 1551.56 | 08-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 42066197.00 | 883.56 | 17-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 20695440.15 | 616.59 | 18-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.207465E+09 | 1021.78 | 19-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.529522E+09 | 1574.17 | 10-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.159914E+10 | 2748.40 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.322229E+10 | 3495.20 | 31-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.425559E+10 | 3955.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 617425.41 | 617425.41 | 145.23 | 06-APR-16:20 | 145.23 | 0.00 |
| May | 0.00 | 0.00 | 0.110944E+09 | 0.110910E+09 | 1145.33 | 20-MAY-16:05 | 1145.33 | 0.00 |
| June | 0.00 | 0.00 | 0.882453E+09 | 0.857955E+09 | 2017.30 | 30-JUN-17:30 | 2017.30 | 0.00 |
| July | 0.00 | 0.00 | 0.231771E+10 | 0.226211E+10 | 2867.69 | 17-JUL-17:16 | 2867.69 | 0.00 |
| August | 0.00 | 0.00 | 0.207112E+10 | 0.206535E+10 | 2805.15 | 06-AUG-16:10 | 2805.15 | 0.00 |
| September | 0.00 | 0.00 | 0.127505E+10 | 0.123641E+10 | 2962.33 | 02-SEP-16:05 | 2962.33 | 0.00 |
| October | 0.00 | 0.00 | 0.229975E+09 | 0.229975E+09 | 1892.09 | 18-OCT-16:10 | 1892.09 | 0.00 |
| November | 0.00 | 0.00 | 103011.26 | 103011.26 | 55.29 | 03-NOV-15:20 | 55.29 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.688797E+10 | 0.676343E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.231771E+10 | 0.226211E+10 | 2962.33 | 2962.33 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 39553411.61 | 39553411.61 | 778.73 | 31-MAY-18:00 | 778.73 | 0.00 |
| June | 0.00 | 0.00 | 0.644490E+09 | 0.624712E+09 | 1824.20 | 28-JUN-18:00 | 1824.20 | 0.00 |
| July | 0.00 | 0.00 | 0.182092E+10 | 0.177312E+10 | 2569.76 | 17-JUL-17:50 | 2569.76 | 0.00 |
| August | 0.00 | 0.00 | 0.135071E+10 | 0.134682E+10 | 2322.48 | 06-AUG-16:40 | 2322.48 | 0.00 |
| September | 0.00 | 0.00 | 0.650739E+09 | 0.621161E+09 | 2176.06 | 04-SEP-17:07 | 2176.06 | 0.00 |
| October | 0.00 | 0.00 | 2442849.84 | 2442849.84 | 362.14 | 18-OCT-16:05 | 362.14 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.450885E+10 | 0.440781E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.182092E+10 | 0.177312E+10 | 2569.76 | 2569.76 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 4970531.76 | 4970531.76 | 462.13 | 27-FEB-15:30 | 462.13 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 27323071.40 | 27323071.40 | 790.00 | 07-APR-14:10 | 790.00 | 0.00 |
| May | 0.00 | 0.00 | 0.153474E+09 | 0.152735E+09 | 2786.22 | 19-MAY-08:63 | 2786.22 | 0.00 |
| June | 0.00 | 0.00 | 0.114834E+10 | 0.111853E+10 | 7076.08 | 22-JUN-08:62 | 6389.08 | 0.00 |
| July | 0.00 | 0.00 | 0.198228E+10 | 0.194713E+10 | 7396.86 | 19-JUL-07:02 | 6107.03 | 0.00 |
| August | 0.00 | 0.00 | 0.204878E+10 | 0.203647E+10 | 6992.29 | 09-AUG-07:02 | 6992.29 | 0.00 |
| September | 0.00 | 0.00 | 0.111157E+10 | 0.107446E+10 | 7164.60 | 07-SEP-07:02 | 6294.71 | 0.00 |
| October | 0.00 | 0.00 | 0.434906E+09 | 0.434906E+09 | 6278.72 | 19-OCT-08:62 | 6278.72 | 0.00 |
| November | 0.00 | 0.00 | 39493943.42 | 39493943.42 | 882.70 | 03-NOV-14:20 | 882.70 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.695113E+10 | 0.683602E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.204878E+10 | 0.203647E+10 | 7396.86 | 6992.29 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 24093595.36 | 24093595.36 | 733.81 | 20-MAY-16:10 | 733.81 | 0.00 |
| June | 0.00 | 0.00 | 0.706580E+09 | 0.684171E+09 | 1569.73 | 29-JUN-15:10 | 1569.73 | 0.00 |
| July | 0.00 | 0.00 | 0.194161E+10 | 0.188950E+10 | 2181.82 | 17-JUL-16:04 | 2181.82 | 0.00 |
| August | 0.00 | 0.00 | 0.143809E+10 | 0.143356E+10 | 2057.58 | 06-AUG-17:08 | 2057.58 | 0.00 |
| September | 0.00 | 0.00 | 0.630948E+09 | 0.604190E+09 | 1909.43 | 03-SEP-16:04 | 1909.43 | 0.00 |
| October | 0.00 | 0.00 | 681059.87 | 681059.87 | 134.13 | 18-OCT-16:05 | 134.13 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.474200E+10 | 0.463620E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.194161E+10 | 0.188950E+10 | 2181.82 | 2181.82 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 20289190.73 | 20289190.73 | 594.95 | 20-MAY-16:10 | 594.95 | 0.00 |
| June | 0.00 | 0.00 | 0.531612E+09 | 0.513524E+09 | 1263.66 | 29-JUN-16:02 | 1263.66 | 0.00 |
| July | 0.00 | 0.00 | 0.152970E+10 | 0.148342E+10 | 1774.35 | 17-JUL-18:00 | 1774.35 | 0.00 |
| August | 0.00 | 0.00 | 0.113997E+10 | 0.113585E+10 | 1666.47 | 06-AUG-17:20 | 1666.47 | 0.00 |
| September | 0.00 | 0.00 | 0.546784E+09 | 0.518756E+09 | 1551.33 | 03-SEP-16:02 | 1551.33 | 0.00 |
| October | 0.00 | 0.00 | 192172.49 | 192172.49 | 89.44 | 18-OCT-16:08 | 89.44 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.376855E+10 | 0.367203E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.152970E+10 | 0.148342E+10 | 1774.35 | 1774.35 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 19626680.53 | 19626680.53 | 593.94 | 20-MAY-16:10 | 593.94 | 0.00 |
| June | 0.00 | 0.00 | 0.537245E+09 | 0.518971E+09 | 1262.51 | 29-JUN-16:04 | 1262.51 | 0.00 |
| July | 0.00 | 0.00 | 0.153716E+10 | 0.149067E+10 | 1768.93 | 17-JUL-18:00 | 1768.93 | 0.00 |
| August | 0.00 | 0.00 | 0.114764E+10 | 0.114347E+10 | 1661.72 | 06-AUG-17:20 | 1661.72 | 0.00 |
| September | 0.00 | 0.00 | 0.547161E+09 | 0.519248E+09 | 1549.62 | 03-SEP-16:04 | 1549.62 | 0.00 |
| October | 0.00 | 0.00 | 150260.65 | 150260.65 | 111.29 | 18-OCT-16:03 | 111.29 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.378898E+10 | 0.369213E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.153716E+10 | 0.149067E+10 | 1768.93 | 1768.93 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 24640.21 | 24640.21 | 25.67 | 27-FEB-15:30 | 25.67 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 85931662.57 | 85879891.63 | 995.57 | 20-MAY-16:05 | 995.57 | 0.00 |
| June | 0.00 | 0.00 | 0.793894E+09 | 0.769972E+09 | 1569.27 | 29-JUN-15:10 | 1569.27 | 0.00 |
| July | 0.00 | 0.00 | 0.205430E+10 | 0.199871E+10 | 2154.36 | 17-JUL-16:04 | 2154.36 | 0.00 |
| August | 0.00 | 0.00 | 0.191168E+10 | 0.190493E+10 | 2207.36 | 10-AUG-15:10 | 2207.36 | 0.00 |
| September | 0.00 | 0.00 | 0.123964E+10 | 0.120146E+10 | 2407.23 | 02-SEP-15:10 | 2407.23 | 0.00 |
| October | 0.00 | 0.00 | 0.314866E+09 | 0.314866E+09 | 1694.22 | 18-OCT-15:10 | 1694.22 | 0.00 |
| November | 0.00 | 0.00 | 3754087.46 | 3754087.46 | 251.60 | 03-NOV-15:10 | 251.60 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.640410E+10 | 0.627959E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.205430E+10 | 0.199871E+10 | 2407.23 | 2407.23 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 96400894.33 | 96334215.76 | 1055.72 | 20-MAY-16:10 | 1055.72 | 0.00 |
| June | 0.00 | 0.00 | 0.893626E+09 | 0.867439E+09 | 1634.69 | 29-JUN-15:10 | 1634.69 | 0.00 |
| July | 0.00 | 0.00 | 0.228062E+10 | 0.221935E+10 | 2259.17 | 17-JUL-16:04 | 2259.17 | 0.00 |
| August | 0.00 | 0.00 | 0.211485E+10 | 0.210708E+10 | 2296.51 | 06-AUG-16:03 | 2296.51 | 0.00 |
| September | 0.00 | 0.00 | 0.138224E+10 | 0.134090E+10 | 2538.49 | 02-SEP-15:10 | 2538.49 | 0.00 |
| October | 0.00 | 0.00 | 0.344086E+09 | 0.344086E+09 | 1736.57 | 18-OCT-15:10 | 1736.57 | 0.00 |
| November | 0.00 | 0.00 | 6075994.30 | 6075994.30 | 444.70 | 04-NOV-17:10 | 444.70 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.711789E+10 | 0.698126E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.228062E+10 | 0.221935E+10 | 2538.49 | 2538.49 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 93045864.31 | 93045864.31 | 2355.71 | 27-FEB-15:30 | 2355.71 | 0.00 |
| March | 0.00 | 0.00 | 21686752.83 | 21686752.83 | 1507.82 | 01-MAR-16:20 | 1507.82 | 0.00 |
| April | 0.00 | 0.00 | 0.390112E+09 | 0.390112E+09 | 3675.01 | 06-APR-16:10 | 3675.01 | 0.00 |
| May | 0.00 | 0.00 | 0.139901E+10 | 0.139742E+10 | 5492.28 | 19-MAY-16:10 | 5492.28 | 0.00 |
| June | 0.00 | 0.00 | 0.396294E+10 | 0.387093E+10 | 5912.64 | 28-JUN-17:40 | 5912.64 | 0.00 |
| July | 0.00 | 0.00 | 0.653764E+10 | 0.639226E+10 | 7206.65 | 17-JUL-16:03 | 7206.65 | 0.00 |
| August | 0.00 | 0.00 | 0.570102E+10 | 0.568422E+10 | 7004.55 | 06-AUG-16:03 | 7004.55 | 0.00 |
| September | 0.00 | 0.00 | 0.335778E+10 | 0.327155E+10 | 7396.84 | 02-SEP-15:20 | 7396.84 | 0.00 |
| October | 0.00 | 0.00 | 0.877191E+09 | 0.877191E+09 | 5390.59 | 18-OCT-15:20 | 5390.59 | 0.00 |
| November | 0.00 | 0.00 | 26183019.33 | 26183019.33 | 1326.74 | 03-NOV-15:30 | 1326.74 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.223666E+11 | 0.220246E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.653764E+10 | 0.639226E+10 | 7396.84 | 7396.84 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 20092561.50 | 20092561.50 | 1071.64 | 25-APR-18:40 | 1071.64 | 0.00 |
| May | 0.00 | 0.00 | 0.879258E+09 | 0.878320E+09 | 4516.97 | 19-MAY-17:40 | 4516.97 | 0.00 |
| June | 0.00 | 0.00 | 0.327791E+10 | 0.319446E+10 | 5621.28 | 28-JUN-18:00 | 5621.28 | 0.00 |
| July | 0.00 | 0.00 | 0.543591E+10 | 0.530368E+10 | 6495.28 | 17-JUL-17:50 | 6495.28 | 0.00 |
| August | 0.00 | 0.00 | 0.405623E+10 | 0.404316E+10 | 5896.61 | 06-AUG-16:30 | 5896.61 | 0.00 |
| September | 0.00 | 0.00 | 0.179164E+10 | 0.172049E+10 | 5280.20 | 02-SEP-17:00 | 5280.20 | 0.00 |
| October | 0.00 | 0.00 | 27701799.88 | 27701799.88 | 1671.27 | 18-OCT-16:08 | 1671.27 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.154887E+11 | 0.151879E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.543591E+10 | 0.530368E+10 | 6495.28 | 6495.28 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 91254927.92 | 91254927.92 | 1926.24 | 27-FEB-15:30 | 1926.24 | 0.00 |
| March | 0.00 | 0.00 | 9307647.85 | 9307647.85 | 773.83 | 01-MAR-16:10 | 773.83 | 0.00 |
| April | 0.00 | 0.00 | 0.424652E+09 | 0.424652E+09 | 2934.92 | 06-APR-16:10 | 2934.92 | 0.00 |
| May | 0.00 | 0.00 | 0.131333E+10 | 0.131173E+10 | 4737.54 | 19-MAY-15:10 | 4737.54 | 0.00 |
| June | 0.00 | 0.00 | 0.417291E+10 | 0.407435E+10 | 5444.26 | 29-JUN-14:30 | 5444.26 | 0.00 |
| July | 0.00 | 0.00 | 0.681593E+10 | 0.665936E+10 | 6416.67 | 25-JUL-13:00 | 6416.67 | 0.00 |
| August | 0.00 | 0.00 | 0.594623E+10 | 0.592793E+10 | 6494.08 | 10-AUG-13:00 | 6494.08 | 0.00 |
| September | 0.00 | 0.00 | 0.335941E+10 | 0.327764E+10 | 6914.54 | 02-SEP-14:00 | 6914.54 | 0.00 |
| October | 0.00 | 0.00 | 0.860646E+09 | 0.860646E+09 | 4790.22 | 18-OCT-14:10 | 4790.22 | 0.00 |
| November | 0.00 | 0.00 | 20471679.34 | 20471679.34 | 1031.19 | 03-NOV-14:10 | 1031.19 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.230141E+11 | 0.226573E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.681593E+10 | 0.665936E+10 | 6914.54 | 6914.54 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 7161290.39 | 7161290.39 | 551.93 | 25-APR-18:50 | 551.93 | 0.00 |
| May | 0.00 | 0.00 | 0.781577E+09 | 0.780665E+09 | 3660.61 | 20-MAY-16:05 | 3660.61 | 0.00 |
| June | 0.00 | 0.00 | 0.347821E+10 | 0.338827E+10 | 4512.52 | 29-JUN-15:10 | 4512.52 | 0.00 |
| July | 0.00 | 0.00 | 0.571404E+10 | 0.557054E+10 | 5271.42 | 17-JUL-16:03 | 5271.42 | 0.00 |
| August | 0.00 | 0.00 | 0.428595E+10 | 0.427124E+10 | 5004.65 | 06-AUG-16:03 | 5004.65 | 0.00 |
| September | 0.00 | 0.00 | 0.174534E+10 | 0.168020E+10 | 4446.55 | 03-SEP-16:10 | 4446.55 | 0.00 |
| October | 0.00 | 0.00 | 22838314.67 | 22838314.67 | 914.25 | 18-OCT-16:05 | 914.25 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.160351E+11 | 0.157209E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.571404E+10 | 0.557054E+10 | 5271.42 | 5271.42 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 688670.73 | 688670.73 | 139.10 | 07-APR-18:00 | 139.10 | 0.00 |
| May | 0.00 | 0.00 | 0.631759E+09 | 0.630375E+09 | 3004.02 | 20-MAY-16:05 | 3004.02 | 0.00 |
| June | 0.00 | 0.00 | 0.257995E+10 | 0.250296E+10 | 3534.40 | 20-JUN-17:30 | 3105.12 | 0.00 |
| July | 0.00 | 0.00 | 0.426033E+10 | 0.413768E+10 | 4091.91 | 17-JUL-18:00 | 4091.91 | 0.00 |
| August | 0.00 | 0.00 | 0.323691E+10 | 0.322349E+10 | 3854.18 | 06-AUG-17:17 | 3854.18 | 0.00 |
| September | 0.00 | 0.00 | 0.145800E+10 | 0.139277E+10 | 3518.62 | 03-SEP-16:06 | 3518.62 | 0.00 |
| October | 0.00 | 0.00 | 21707955.73 | 21707955.73 | 881.56 | 18-OCT-16:10 | 881.56 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.121893E+11 | 0.119097E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.426033E+10 | 0.413768E+10 | 4091.91 | 4091.91 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 819784.56 | 819784.56 | 152.90 | 07-APR-18:00 | 152.90 | 0.00 |
| May | 0.00 | 0.00 | 0.631381E+09 | 0.630003E+09 | 3001.51 | 20-MAY-16:08 | 3001.51 | 0.00 |
| June | 0.00 | 0.00 | 0.259311E+10 | 0.251586E+10 | 3527.06 | 20-JUN-17:30 | 3098.58 | 0.00 |
| July | 0.00 | 0.00 | 0.427201E+10 | 0.414908E+10 | 4072.64 | 17-JUL-18:00 | 4072.64 | 0.00 |
| August | 0.00 | 0.00 | 0.325037E+10 | 0.323687E+10 | 3843.66 | 06-AUG-17:20 | 3843.66 | 0.00 |
| September | 0.00 | 0.00 | 0.146084E+10 | 0.139585E+10 | 3510.72 | 03-SEP-16:02 | 3510.72 | 0.00 |
| October | 0.00 | 0.00 | 21677147.23 | 21677147.23 | 868.08 | 18-OCT-16:05 | 868.08 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.122302E+11 | 0.119501E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.427201E+10 | 0.414908E+10 | 4072.64 | 4072.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.137073E+09 | 0.137073E+09 | 2224.79 | 27-FEB-15:30 | 2224.79 | 0.00 |
| March | 0.00 | 0.00 | 33722789.66 | 33722789.66 | 1445.78 | 01-MAR-15:20 | 1445.78 | 0.00 |
| April | 0.00 | 0.00 | 0.371861E+09 | 0.371861E+09 | 2677.48 | 06-APR-16:10 | 2677.48 | 0.00 |
| May | 0.00 | 0.00 | 0.115421E+10 | 0.115198E+10 | 3888.37 | 19-MAY-15:10 | 3888.37 | 0.00 |
| June | 0.00 | 0.00 | 0.327893E+10 | 0.319205E+10 | 4218.76 | 29-JUN-14:30 | 4218.76 | 0.00 |
| July | 0.00 | 0.00 | 0.536894E+10 | 0.523153E+10 | 5016.63 | 25-JUL-15:10 | 5016.63 | 0.00 |
| August | 0.00 | 0.00 | 0.491312E+10 | 0.489516E+10 | 5206.95 | 10-AUG-15:10 | 5206.95 | 0.00 |
| September | 0.00 | 0.00 | 0.312617E+10 | 0.304400E+10 | 5720.86 | 02-SEP-14:10 | 5720.86 | 0.00 |
| October | 0.00 | 0.00 | 0.111675E+10 | 0.111675E+10 | 4634.14 | 18-OCT-14:10 | 4634.14 | 0.00 |
| November | 0.00 | 0.00 | 0.100911E+09 | 0.100911E+09 | 1743.71 | 03-NOV-14:10 | 1743.71 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.196017E+11 | 0.192750E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.536894E+10 | 0.523153E+10 | 5720.86 | 5720.86 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.139000E+09 | 0.139000E+09 | 2243.67 | 26-FEB-13:50 | 2243.67 | 0.00 |
| March | 0.00 | 0.00 | 34354834.70 | 34354834.70 | 1458.27 | 01-MAR-15:20 | 1458.27 | 0.00 |
| April | 0.00 | 0.00 | 0.382097E+09 | 0.382097E+09 | 2699.86 | 06-APR-16:10 | 2699.86 | 0.00 |
| May | 0.00 | 0.00 | 0.115536E+10 | 0.115314E+10 | 3892.35 | 19-MAY-15:10 | 3892.35 | 0.00 |
| June | 0.00 | 0.00 | 0.329139E+10 | 0.320430E+10 | 4227.64 | 29-JUN-14:30 | 4227.64 | 0.00 |
| July | 0.00 | 0.00 | 0.538047E+10 | 0.524279E+10 | 5022.14 | 25-JUL-15:10 | 5022.14 | 0.00 |
| August | 0.00 | 0.00 | 0.492554E+10 | 0.490752E+10 | 5211.46 | 10-AUG-15:10 | 5211.46 | 0.00 |
| September | 0.00 | 0.00 | 0.313298E+10 | 0.305098E+10 | 5733.16 | 02-SEP-14:10 | 5733.16 | 0.00 |
| October | 0.00 | 0.00 | 0.112302E+10 | 0.112302E+10 | 4641.68 | 18-OCT-14:10 | 4641.68 | 0.00 |
| November | 0.00 | 0.00 | 0.102437E+09 | 0.102437E+09 | 1766.82 | 03-NOV-14:10 | 1766.82 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.196666E+11 | 0.193396E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.538047E+10 | 0.524279E+10 | 5733.16 | 5733.16 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 90581637.23 | 90581637.23 | 1876.24 | 26-FEB-17:00 | 1876.24 | 0.00 |
| March | 0.00 | 0.00 | 83466315.83 | 83466315.83 | 1231.00 | 22-MAR-16:10 | 1231.00 | 0.00 |
| April | 0.00 | 0.00 | 0.359786E+09 | 0.359786E+09 | 2756.11 | 06-APR-16:10 | 2756.11 | 0.00 |
| May | 0.00 | 0.00 | 0.832357E+09 | 0.832074E+09 | 3649.16 | 19-MAY-16:07 | 3649.16 | 0.00 |
| June | 0.00 | 0.00 | 0.204611E+10 | 0.200464E+10 | 3831.44 | 30-JUN-16:06 | 3831.44 | 0.00 |
| July | 0.00 | 0.00 | 0.343737E+10 | 0.337647E+10 | 4883.62 | 17-JUL-16:04 | 4883.62 | 0.00 |
| August | 0.00 | 0.00 | 0.292052E+10 | 0.291425E+10 | 4633.27 | 06-AUG-16:02 | 4633.27 | 0.00 |
| September | 0.00 | 0.00 | 0.166436E+10 | 0.162777E+10 | 4821.00 | 02-SEP-15:20 | 4821.00 | 0.00 |
| October | 0.00 | 0.00 | 0.424039E+09 | 0.424039E+09 | 3268.10 | 18-OCT-15:20 | 3268.10 | 0.00 |
| November | 0.00 | 0.00 | 37307462.88 | 37307462.88 | 1376.94 | 03-NOV-15:20 | 1376.94 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.118959E+11 | 0.117504E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.343737E+10 | 0.337647E+10 | 4883.62 | 4883.62 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 65712987.68 | 65712987.68 | 1184.73 | 06-APR-17:20 | 1184.73 | 0.00 |
| May | 0.00 | 0.00 | 0.534220E+09 | 0.534095E+09 | 3059.98 | 19-MAY-17:30 | 3059.98 | 0.00 |
| June | 0.00 | 0.00 | 0.168255E+10 | 0.164401E+10 | 3632.96 | 28-JUN-18:00 | 3632.96 | 0.00 |
| July | 0.00 | 0.00 | 0.284893E+10 | 0.279299E+10 | 4335.32 | 17-JUL-17:30 | 4335.32 | 0.00 |
| August | 0.00 | 0.00 | 0.206758E+10 | 0.206265E+10 | 3942.05 | 06-AUG-16:30 | 3942.05 | 0.00 |
| September | 0.00 | 0.00 | 0.880400E+09 | 0.850172E+09 | 3463.07 | 02-SEP-17:00 | 3463.07 | 0.00 |
| October | 0.00 | 0.00 | 26035066.89 | 26035066.89 | 1230.93 | 18-OCT-16:05 | 1230.93 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.810543E+10 | 0.797566E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.284893E+10 | 0.279299E+10 | 4335.32 | 4335.32 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 78562143.07 | 78562143.07 | 1657.51 | 26-FEB-14:00 | 1657.51 | 0.00 |
| March | 0.00 | 0.00 | 64949776.37 | 64949776.37 | 1040.45 | 20-MAR-14:30 | 1040.45 | 0.00 |
| April | 0.00 | 0.00 | 0.343582E+09 | 0.343582E+09 | 2100.30 | 06-APR-15:20 | 2100.30 | 0.00 |
| May | 0.00 | 0.00 | 0.750847E+09 | 0.750311E+09 | 3121.25 | 19-MAY-15:10 | 3121.25 | 0.00 |
| June | 0.00 | 0.00 | 0.210745E+10 | 0.206268E+10 | 3555.45 | 23-JUN-13:30 | 3555.45 | 0.00 |
| July | 0.00 | 0.00 | 0.355492E+10 | 0.348765E+10 | 4288.42 | 25-JUL-13:00 | 4288.42 | 0.00 |
| August | 0.00 | 0.00 | 0.301370E+10 | 0.300684E+10 | 4271.29 | 10-AUG-13:00 | 4271.29 | 0.00 |
| September | 0.00 | 0.00 | 0.163177E+10 | 0.159748E+10 | 4491.39 | 02-SEP-14:00 | 4491.39 | 0.00 |
| October | 0.00 | 0.00 | 0.385557E+09 | 0.385557E+09 | 2857.07 | 18-OCT-14:10 | 2857.07 | 0.00 |
| November | 0.00 | 0.00 | 26902954.23 | 26902954.23 | 1152.56 | 03-NOV-14:00 | 1152.56 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.119582E+11 | 0.118045E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.355492E+10 | 0.348765E+10 | 4491.39 | 4491.39 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 22416455.93 | 22416455.93 | 543.18 | 24-APR-18:50 | 543.18 | 0.00 |
| May | 0.00 | 0.00 | 0.450301E+09 | 0.450147E+09 | 2265.59 | 20-MAY-16:05 | 2265.59 | 0.00 |
| June | 0.00 | 0.00 | 0.173683E+10 | 0.169492E+10 | 2901.25 | 29-JUN-15:10 | 2901.25 | 0.00 |
| July | 0.00 | 0.00 | 0.297001E+10 | 0.290758E+10 | 3481.77 | 17-JUL-16:07 | 3481.77 | 0.00 |
| August | 0.00 | 0.00 | 0.214329E+10 | 0.213765E+10 | 3264.33 | 06-AUG-16:02 | 3264.33 | 0.00 |
| September | 0.00 | 0.00 | 0.826965E+09 | 0.799804E+09 | 2814.62 | 03-SEP-16:04 | 2814.62 | 0.00 |
| October | 0.00 | 0.00 | 11783911.39 | 11783911.39 | 652.97 | 18-OCT-16:10 | 652.97 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.816160E+10 | 0.802431E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.297001E+10 | 0.290758E+10 | 3481.77 | 3481.77 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 6632255.04 | 6632255.04 | 308.80 | 25-APR-18:50 | 308.80 | 0.00 |
| May | 0.00 | 0.00 | 0.333353E+09 | 0.333195E+09 | 1895.29 | 20-MAY-16:05 | 1895.29 | 0.00 |
| June | 0.00 | 0.00 | 0.125145E+10 | 0.121663E+10 | 2294.51 | 20-JUN-17:30 | 2046.97 | 0.00 |
| July | 0.00 | 0.00 | 0.220856E+10 | 0.215581E+10 | 2809.30 | 17-JUL-16:04 | 2809.30 | 0.00 |
| August | 0.00 | 0.00 | 0.158947E+10 | 0.158470E+10 | 2614.19 | 06-AUG-16:17 | 2614.19 | 0.00 |
| September | 0.00 | 0.00 | 0.664115E+09 | 0.637055E+09 | 2293.17 | 03-SEP-16:02 | 2293.17 | 0.00 |
| October | 0.00 | 0.00 | 6030289.53 | 6030289.53 | 506.33 | 18-OCT-16:05 | 506.33 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.605961E+10 | 0.594005E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.220856E+10 | 0.215581E+10 | 2809.30 | 2809.30 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 6727497.95 | 6727497.95 | 307.78 | 25-APR-18:50 | 307.78 | 0.00 |
| May | 0.00 | 0.00 | 0.334198E+09 | 0.334039E+09 | 1892.49 | 20-MAY-16:05 | 1892.49 | 0.00 |
| June | 0.00 | 0.00 | 0.126096E+10 | 0.122598E+10 | 2281.19 | 20-JUN-17:30 | 2034.76 | 0.00 |
| July | 0.00 | 0.00 | 0.221828E+10 | 0.216530E+10 | 2798.45 | 17-JUL-16:04 | 2798.45 | 0.00 |
| August | 0.00 | 0.00 | 0.159927E+10 | 0.159447E+10 | 2605.12 | 06-AUG-16:17 | 2605.12 | 0.00 |
| September | 0.00 | 0.00 | 0.664998E+09 | 0.638106E+09 | 2283.96 | 03-SEP-16:04 | 2283.96 | 0.00 |
| October | 0.00 | 0.00 | 6274183.22 | 6274183.22 | 501.33 | 18-OCT-16:05 | 501.33 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.609071E+10 | 0.597089E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.221828E+10 | 0.216530E+10 | 2798.45 | 2798.45 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 800780.38 | 800780.38 | 183.10 | 15-JAN-13:40 | 183.10 | 0.00 |
| February | 0.00 | 0.00 | 88642080.58 | 88642080.58 | 1616.48 | 26-FEB-14:00 | 1616.48 | 0.00 |
| March | 0.00 | 0.00 | 72940235.26 | 72940235.26 | 964.57 | 20-MAR-15:10 | 964.57 | 0.00 |
| April | 0.00 | 0.00 | 0.260707E+09 | 0.260707E+09 | 1822.67 | 06-APR-16:10 | 1822.67 | 0.00 |
| May | 0.00 | 0.00 | 0.601780E+09 | 0.601426E+09 | 2599.70 | 19-MAY-15:10 | 2599.70 | 0.00 |
| June | 0.00 | 0.00 | 0.161555E+10 | 0.157738E+10 | 2843.68 | 29-JUN-14:30 | 2843.68 | 0.00 |
| July | 0.00 | 0.00 | 0.280106E+10 | 0.274276E+10 | 3450.01 | 25-JUL-14:40 | 3450.01 | 0.00 |
| August | 0.00 | 0.00 | 0.245771E+10 | 0.245143E+10 | 3534.35 | 09-AUG-13:50 | 3534.35 | 0.00 |
| September | 0.00 | 0.00 | 0.144922E+10 | 0.141435E+10 | 3796.89 | 02-SEP-14:00 | 3796.89 | 0.00 |
| October | 0.00 | 0.00 | 0.395111E+09 | 0.395111E+09 | 2630.28 | 18-OCT-14:20 | 2630.28 | 0.00 |
| November | 0.00 | 0.00 | 46089052.82 | 46089052.82 | 1242.48 | 03-NOV-14:10 | 1242.48 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.978961E+10 | 0.965164E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.280106E+10 | 0.274276E+10 | 3796.89 | 3796.89 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 996687.92 | 996687.92 | 176.18 | 15-JAN-13:40 | 176.18 | 0.00 |
| February | 0.00 | 0.00 | 90296113.03 | 90296113.03 | 1640.25 | 26-FEB-14:00 | 1640.25 | 0.00 |
| March | 0.00 | 0.00 | 75848003.10 | 75848003.10 | 977.91 | 20-MAR-15:10 | 977.91 | 0.00 |
| April | 0.00 | 0.00 | 0.267132E+09 | 0.267132E+09 | 1822.70 | 06-APR-16:10 | 1822.70 | 0.00 |
| May | 0.00 | 0.00 | 0.605255E+09 | 0.604877E+09 | 2606.50 | 19-MAY-15:10 | 2606.50 | 0.00 |
| June | 0.00 | 0.00 | 0.162626E+10 | 0.158794E+10 | 2853.02 | 29-JUN-14:30 | 2853.02 | 0.00 |
| July | 0.00 | 0.00 | 0.281119E+10 | 0.275266E+10 | 3457.43 | 25-JUL-14:30 | 3457.43 | 0.00 |
| August | 0.00 | 0.00 | 0.246770E+10 | 0.246138E+10 | 3548.18 | 09-AUG-13:40 | 3548.18 | 0.00 |
| September | 0.00 | 0.00 | 0.145391E+10 | 0.141917E+10 | 3808.58 | 02-SEP-14:00 | 3808.58 | 0.00 |
| October | 0.00 | 0.00 | 0.398838E+09 | 0.398838E+09 | 2639.85 | 18-OCT-14:10 | 2639.85 | 0.00 |
| November | 0.00 | 0.00 | 47165328.46 | 47165328.46 | 1257.62 | 03-NOV-14:10 | 1257.62 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.984460E+10 | 0.970630E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.281119E+10 | 0.275266E+10 | 3808.58 | 3808.58 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.217614E+09 | 1.04 | 187.95 | 10-JAN-23:10 | 1.06 |
| February | 0.129092E+09 | 0.94 | 141.46 | 04-FEB-08:10 | 1.06 |
| March | 0.113947E+09 | 0.95 | 139.50 | 05-MAR-01:10 | 1.06 |
| April | 59317669.98 | 0.74 | 88.49 | 29-APR-05:00 | 1.05 |
| May | 42303562.10 | 0.56 | 95.02 | 20-MAY-16:05 | 1.19 |
| June | 71972568.16 | 0.58 | 169.30 | 29-JUN-15:10 | 1.16 |
| July | 0.187307E+09 | 1.02 | 244.55 | 17-JUL-16:10 | 1.13 |
| August | 0.168844E+09 | 0.95 | 238.76 | 06-AUG-16:02 | 1.14 |
| September | 0.103382E+09 | 0.68 | 244.19 | 02-SEP-15:20 | 1.13 |
| October | 27910594.54 | 0.40 | 153.78 | 18-OCT-15:30 | 1.17 |
| November | 59612348.22 | 0.66 | 105.74 | 27-NOV-05:00 | 1.06 |
| December | 0.154480E+09 | 1.04 | 166.20 | 31-DEC-08:08 | 1.06 |
| Annual Sum or Average | 0.133578E+10 | 0.80 | |||
| Minimum of Months | 27910594.54 | 0.40 | 88.49 | 1.05 | |
| Maximum of Months | 0.217614E+09 | 1.04 | 244.55 | 1.19 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.257885E+09 | 1.05 | 189.33 | 10-JAN-23:10 | 1.06 |
| February | 0.170324E+09 | 1.05 | 147.39 | 04-FEB-08:13 | 1.06 |
| March | 0.153257E+09 | 1.05 | 145.72 | 05-MAR-00:10 | 1.06 |
| April | 81675606.23 | 0.94 | 90.53 | 29-APR-05:00 | 1.05 |
| May | 44755463.61 | 0.61 | 75.96 | 08-MAY-05:00 | 1.05 |
| June | 52870716.79 | 0.49 | 151.98 | 28-JUN-18:00 | 1.17 |
| July | 0.147642E+09 | 0.96 | 217.27 | 17-JUL-17:50 | 1.13 |
| August | 0.111101E+09 | 0.82 | 199.09 | 06-AUG-16:40 | 1.14 |
| September | 57985192.28 | 0.59 | 180.62 | 02-SEP-17:00 | 1.15 |
| October | 24088895.94 | 0.46 | 61.26 | 10-OCT-07:03 | 1.05 |
| November | 97311211.54 | 0.99 | 114.44 | 27-NOV-05:00 | 1.06 |
| December | 0.192581E+09 | 1.05 | 169.66 | 31-DEC-08:14 | 1.06 |
| Annual Sum or Average | 0.139148E+10 | 0.84 | |||
| Minimum of Months | 24088895.94 | 0.46 | 61.26 | 1.05 | |
| Maximum of Months | 0.257885E+09 | 1.05 | 217.27 | 1.17 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.127231E+10 | 1.06 | 475.03 | 01-JAN-00:10 | 1.05 |
| February | 0.114919E+10 | 1.05 | 475.03 | 01-FEB-00:10 | 1.06 |
| March | 0.127231E+10 | 1.05 | 475.03 | 01-MAR-00:10 | 1.05 |
| April | 0.123127E+10 | 1.05 | 475.03 | 01-APR-00:10 | 1.05 |
| May | 0.127231E+10 | 1.05 | 475.03 | 01-MAY-00:10 | 1.05 |
| June | 0.123127E+10 | 1.05 | 475.03 | 01-JUN-00:10 | 1.05 |
| July | 0.127231E+10 | 1.04 | 475.03 | 01-JUL-00:10 | 1.05 |
| August | 0.127231E+10 | 1.05 | 475.03 | 01-AUG-00:10 | 1.05 |
| September | 0.123127E+10 | 1.05 | 475.03 | 01-SEP-00:10 | 1.05 |
| October | 0.127231E+10 | 1.05 | 475.03 | 01-OCT-00:10 | 1.05 |
| November | 0.123127E+10 | 1.05 | 475.03 | 01-NOV-00:10 | 1.05 |
| December | 0.127231E+10 | 1.05 | 475.03 | 01-DEC-00:10 | 1.05 |
| Annual Sum or Average | 0.149805E+11 | 1.05 | |||
| Minimum of Months | 0.114919E+10 | 1.04 | 475.03 | 1.05 | |
| Maximum of Months | 0.127231E+10 | 1.06 | 475.03 | 1.06 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.250894E+09 | 1.05 | 185.33 | 10-JAN-23:10 | 1.06 |
| February | 0.166166E+09 | 1.05 | 144.01 | 04-FEB-08:13 | 1.06 |
| March | 0.148096E+09 | 1.05 | 143.15 | 05-MAR-00:10 | 1.06 |
| April | 78006295.93 | 0.92 | 90.43 | 29-APR-05:00 | 1.05 |
| May | 42729157.29 | 0.60 | 74.06 | 08-MAY-05:00 | 1.05 |
| June | 57629782.59 | 0.51 | 132.87 | 29-JUN-15:10 | 1.17 |
| July | 0.156452E+09 | 0.99 | 186.81 | 17-JUL-16:04 | 1.14 |
| August | 0.117680E+09 | 0.87 | 176.43 | 06-AUG-16:02 | 1.14 |
| September | 55594796.75 | 0.58 | 160.19 | 03-SEP-16:04 | 1.15 |
| October | 22983744.26 | 0.47 | 58.37 | 10-OCT-06:50 | 1.05 |
| November | 95615805.36 | 1.00 | 111.94 | 27-NOV-05:00 | 1.06 |
| December | 0.188209E+09 | 1.05 | 165.89 | 31-DEC-08:20 | 1.06 |
| Annual Sum or Average | 0.138006E+10 | 0.84 | |||
| Minimum of Months | 22983744.26 | 0.47 | 58.37 | 1.05 | |
| Maximum of Months | 0.250894E+09 | 1.05 | 186.81 | 1.17 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.179939E+09 | 1.05 | 136.37 | 10-JAN-23:10 | 1.06 |
| February | 0.117421E+09 | 1.05 | 105.90 | 04-FEB-08:13 | 1.06 |
| March | 0.103195E+09 | 1.05 | 102.77 | 05-MAR-00:10 | 1.06 |
| April | 51357372.14 | 0.91 | 61.12 | 29-APR-05:00 | 1.05 |
| May | 27322655.78 | 0.56 | 49.90 | 20-MAY-16:10 | 1.20 |
| June | 43166121.42 | 0.50 | 106.27 | 29-JUN-16:02 | 1.17 |
| July | 0.123830E+09 | 1.03 | 151.50 | 17-JUL-18:00 | 1.15 |
| August | 93717743.08 | 0.91 | 142.88 | 06-AUG-17:04 | 1.15 |
| September | 45978576.06 | 0.54 | 130.93 | 03-SEP-16:02 | 1.16 |
| October | 11388005.18 | 0.34 | 40.39 | 10-OCT-07:06 | 1.05 |
| November | 62589215.10 | 0.92 | 78.64 | 27-NOV-05:00 | 1.06 |
| December | 0.131956E+09 | 1.05 | 123.63 | 31-DEC-08:20 | 1.06 |
| Annual Sum or Average | 0.991859E+09 | 0.82 | |||
| Minimum of Months | 11388005.18 | 0.34 | 40.39 | 1.05 | |
| Maximum of Months | 0.179939E+09 | 1.05 | 151.50 | 1.20 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.179779E+09 | 1.05 | 136.31 | 10-JAN-23:10 | 1.06 |
| February | 0.117341E+09 | 1.05 | 105.86 | 04-FEB-08:13 | 1.06 |
| March | 0.103061E+09 | 1.05 | 102.76 | 05-MAR-00:10 | 1.06 |
| April | 51269466.60 | 0.91 | 61.16 | 29-APR-05:00 | 1.05 |
| May | 27295528.21 | 0.55 | 49.82 | 20-MAY-16:10 | 1.20 |
| June | 43613283.46 | 0.51 | 106.17 | 29-JUN-16:04 | 1.17 |
| July | 0.124409E+09 | 1.03 | 151.04 | 17-JUL-18:00 | 1.15 |
| August | 94329590.11 | 0.91 | 142.48 | 06-AUG-17:04 | 1.15 |
| September | 45973777.53 | 0.53 | 130.77 | 03-SEP-16:04 | 1.16 |
| October | 11370378.24 | 0.34 | 40.34 | 10-OCT-07:07 | 1.05 |
| November | 62589657.83 | 0.92 | 78.59 | 27-NOV-05:00 | 1.06 |
| December | 0.131884E+09 | 1.05 | 123.57 | 31-DEC-08:20 | 1.06 |
| Annual Sum or Average | 0.992916E+09 | 0.82 | |||
| Minimum of Months | 11370378.24 | 0.34 | 40.34 | 1.05 | |
| Maximum of Months | 0.179779E+09 | 1.05 | 151.04 | 1.20 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.142646E+09 | 1.01 | 135.50 | 10-JAN-23:10 | 1.06 |
| February | 80021122.55 | 0.87 | 99.76 | 04-FEB-08:16 | 1.06 |
| March | 66930498.98 | 0.87 | 95.80 | 05-MAR-00:10 | 1.06 |
| April | 31993487.40 | 0.63 | 58.42 | 29-APR-05:00 | 1.05 |
| May | 25625654.90 | 0.48 | 82.39 | 20-MAY-16:05 | 1.19 |
| June | 64290261.57 | 0.64 | 133.13 | 29-JUN-15:10 | 1.17 |
| July | 0.165666E+09 | 1.08 | 185.25 | 17-JUL-16:10 | 1.14 |
| August | 0.155481E+09 | 1.04 | 186.61 | 10-AUG-15:10 | 1.14 |
| September | 99185343.73 | 0.72 | 199.02 | 02-SEP-15:10 | 1.13 |
| October | 28830592.11 | 0.44 | 137.49 | 18-OCT-15:10 | 1.17 |
| November | 31064567.66 | 0.46 | 70.28 | 27-NOV-05:00 | 1.06 |
| December | 96911936.55 | 0.99 | 120.64 | 31-DEC-08:20 | 1.06 |
| Annual Sum or Average | 0.988648E+09 | 0.77 | |||
| Minimum of Months | 25625654.90 | 0.44 | 58.42 | 1.05 | |
| Maximum of Months | 0.165666E+09 | 1.08 | 199.02 | 1.19 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.154003E+09 | 1.02 | 141.53 | 10-JAN-23:10 | 1.06 |
| February | 87974855.75 | 0.89 | 106.44 | 05-FEB-07:50 | 1.06 |
| March | 73209501.34 | 0.88 | 102.34 | 05-MAR-00:10 | 1.06 |
| April | 34115713.89 | 0.64 | 61.39 | 29-APR-05:00 | 1.05 |
| May | 28014355.50 | 0.49 | 87.23 | 20-MAY-16:10 | 1.19 |
| June | 72256947.15 | 0.69 | 138.42 | 29-JUN-15:10 | 1.17 |
| July | 0.183391E+09 | 1.11 | 193.65 | 17-JUL-16:10 | 1.14 |
| August | 0.171561E+09 | 1.08 | 195.41 | 06-AUG-16:03 | 1.14 |
| September | 0.110356E+09 | 0.75 | 209.06 | 02-SEP-15:10 | 1.13 |
| October | 31320637.98 | 0.46 | 140.78 | 18-OCT-15:10 | 1.17 |
| November | 34084925.94 | 0.48 | 76.40 | 27-NOV-05:00 | 1.06 |
| December | 0.106702E+09 | 1.01 | 128.63 | 31-DEC-08:20 | 1.06 |
| Annual Sum or Average | 0.108699E+10 | 0.79 | |||
| Minimum of Months | 28014355.50 | 0.46 | 61.39 | 1.05 | |
| Maximum of Months | 0.183391E+09 | 1.11 | 209.06 | 1.19 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.370655E+09 | 0.97 | 357.87 | 10-JAN-23:10 | 1.06 |
| February | 0.195431E+09 | 0.83 | 262.51 | 04-FEB-03:00 | 1.06 |
| March | 0.128422E+09 | 0.69 | 252.37 | 05-MAR-01:10 | 1.06 |
| April | 65304818.82 | 0.47 | 299.23 | 06-APR-16:10 | 1.19 |
| May | 0.141176E+09 | 0.61 | 437.90 | 19-MAY-16:10 | 1.16 |
| June | 0.319649E+09 | 0.90 | 489.70 | 28-JUN-17:40 | 1.16 |
| July | 0.527551E+09 | 1.11 | 615.99 | 17-JUL-16:10 | 1.13 |
| August | 0.464104E+09 | 1.05 | 597.44 | 06-AUG-16:03 | 1.14 |
| September | 0.273130E+09 | 0.76 | 612.40 | 02-SEP-15:20 | 1.13 |
| October | 88625527.46 | 0.44 | 436.15 | 18-OCT-15:20 | 1.17 |
| November | 0.109439E+09 | 0.57 | 228.93 | 27-NOV-05:00 | 1.06 |
| December | 0.269557E+09 | 0.97 | 311.11 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.295304E+10 | 0.78 | |||
| Minimum of Months | 65304818.82 | 0.44 | 228.93 | 1.06 | |
| Maximum of Months | 0.527551E+09 | 1.11 | 615.99 | 1.19 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.457061E+09 | 1.05 | 361.56 | 10-JAN-23:10 | 1.06 |
| February | 0.266925E+09 | 0.98 | 270.38 | 04-FEB-03:00 | 1.06 |
| March | 0.199988E+09 | 0.95 | 261.84 | 05-MAR-01:10 | 1.06 |
| April | 57258862.65 | 0.52 | 143.39 | 29-APR-05:00 | 1.05 |
| May | 0.105622E+09 | 0.57 | 358.60 | 19-MAY-17:40 | 1.17 |
| June | 0.264886E+09 | 0.86 | 463.95 | 28-JUN-18:00 | 1.15 |
| July | 0.440179E+09 | 1.10 | 550.65 | 17-JUL-17:50 | 1.14 |
| August | 0.333015E+09 | 0.98 | 507.26 | 06-AUG-16:30 | 1.15 |
| September | 0.153758E+09 | 0.63 | 447.24 | 02-SEP-17:00 | 1.15 |
| October | 44042887.62 | 0.41 | 139.53 | 18-OCT-16:08 | 1.21 |
| November | 0.181996E+09 | 0.91 | 246.40 | 27-NOV-05:00 | 1.06 |
| December | 0.351282E+09 | 1.05 | 317.26 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.285601E+10 | 0.83 | |||
| Minimum of Months | 44042887.62 | 0.41 | 139.53 | 1.05 | |
| Maximum of Months | 0.457061E+09 | 1.10 | 550.65 | 1.21 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.359846E+09 | 0.97 | 350.64 | 10-JAN-23:10 | 1.06 |
| February | 0.190728E+09 | 0.84 | 257.73 | 04-FEB-03:00 | 1.06 |
| March | 0.121041E+09 | 0.66 | 247.93 | 05-MAR-01:10 | 1.06 |
| April | 67815129.66 | 0.50 | 239.66 | 06-APR-16:10 | 1.19 |
| May | 0.133991E+09 | 0.61 | 378.05 | 19-MAY-15:10 | 1.16 |
| June | 0.334658E+09 | 0.94 | 454.36 | 29-JUN-14:30 | 1.15 |
| July | 0.545938E+09 | 1.12 | 534.67 | 25-JUL-13:00 | 1.13 |
| August | 0.480864E+09 | 1.07 | 538.71 | 10-AUG-15:00 | 1.13 |
| September | 0.271904E+09 | 0.77 | 564.69 | 02-SEP-14:10 | 1.12 |
| October | 86357326.02 | 0.46 | 388.13 | 18-OCT-14:10 | 1.16 |
| November | 0.107300E+09 | 0.56 | 224.24 | 27-NOV-05:00 | 1.06 |
| December | 0.263190E+09 | 0.97 | 305.33 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.296363E+10 | 0.79 | |||
| Minimum of Months | 67815129.66 | 0.46 | 224.24 | 1.06 | |
| Maximum of Months | 0.545938E+09 | 1.12 | 564.69 | 1.19 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.443924E+09 | 1.05 | 353.61 | 10-JAN-23:10 | 1.06 |
| February | 0.259548E+09 | 0.98 | 264.87 | 04-FEB-03:00 | 1.06 |
| March | 0.190949E+09 | 0.93 | 256.80 | 05-MAR-01:10 | 1.06 |
| April | 53756277.27 | 0.49 | 143.08 | 29-APR-05:00 | 1.05 |
| May | 97235842.57 | 0.54 | 299.15 | 20-MAY-16:05 | 1.17 |
| June | 0.279586E+09 | 0.90 | 379.34 | 29-JUN-15:10 | 1.16 |
| July | 0.459447E+09 | 1.11 | 453.02 | 17-JUL-16:04 | 1.14 |
| August | 0.349935E+09 | 1.01 | 431.86 | 06-AUG-16:03 | 1.15 |
| September | 0.148525E+09 | 0.64 | 375.14 | 03-SEP-16:10 | 1.16 |
| October | 41522899.88 | 0.39 | 120.36 | 10-OCT-06:00 | 1.05 |
| November | 0.178620E+09 | 0.93 | 241.27 | 27-NOV-05:00 | 1.06 |
| December | 0.342939E+09 | 1.05 | 310.96 | 31-DEC-03:00 | 1.06 |
| Annual Sum or Average | 0.284599E+10 | 0.84 | |||
| Minimum of Months | 41522899.88 | 0.39 | 120.36 | 1.05 | |
| Maximum of Months | 0.459447E+09 | 1.11 | 453.02 | 1.17 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.296038E+09 | 1.05 | 245.98 | 10-JAN-23:10 | 1.06 |
| February | 0.168231E+09 | 0.96 | 183.02 | 04-FEB-03:00 | 1.06 |
| March | 0.119545E+09 | 0.91 | 174.95 | 05-MAR-00:10 | 1.06 |
| April | 24108587.20 | 0.37 | 93.69 | 29-APR-05:00 | 1.05 |
| May | 67151701.90 | 0.51 | 246.27 | 20-MAY-16:05 | 1.17 |
| June | 0.208504E+09 | 0.94 | 285.67 | 29-JUN-16:04 | 1.17 |
| July | 0.344711E+09 | 1.14 | 351.30 | 17-JUL-18:00 | 1.15 |
| August | 0.265758E+09 | 1.06 | 333.86 | 06-AUG-16:17 | 1.16 |
| September | 0.119607E+09 | 0.58 | 298.65 | 03-SEP-16:06 | 1.16 |
| October | 17558957.79 | 0.26 | 77.24 | 10-OCT-06:00 | 1.05 |
| November | 0.103544E+09 | 0.77 | 159.44 | 27-NOV-05:00 | 1.06 |
| December | 0.220362E+09 | 1.05 | 215.29 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.195512E+10 | 0.80 | |||
| Minimum of Months | 17558957.79 | 0.26 | 77.24 | 1.05 | |
| Maximum of Months | 0.344711E+09 | 1.14 | 351.30 | 1.17 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.295738E+09 | 1.05 | 245.88 | 10-JAN-23:10 | 1.06 |
| February | 0.168118E+09 | 0.96 | 182.97 | 04-FEB-03:00 | 1.06 |
| March | 0.119381E+09 | 0.91 | 174.98 | 05-MAR-00:10 | 1.06 |
| April | 24003185.99 | 0.36 | 93.73 | 29-APR-05:00 | 1.05 |
| May | 67222709.18 | 0.51 | 246.07 | 20-MAY-16:08 | 1.17 |
| June | 0.209541E+09 | 0.94 | 285.42 | 29-JUN-16:08 | 1.17 |
| July | 0.345599E+09 | 1.14 | 349.69 | 17-JUL-18:00 | 1.15 |
| August | 0.266822E+09 | 1.06 | 333.37 | 06-AUG-16:03 | 1.16 |
| September | 0.119806E+09 | 0.58 | 297.98 | 03-SEP-16:02 | 1.16 |
| October | 17561594.91 | 0.26 | 77.18 | 10-OCT-06:00 | 1.05 |
| November | 0.103584E+09 | 0.77 | 159.39 | 27-NOV-05:00 | 1.06 |
| December | 0.220238E+09 | 1.05 | 215.22 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.195762E+10 | 0.80 | |||
| Minimum of Months | 17561594.91 | 0.26 | 77.18 | 1.05 | |
| Maximum of Months | 0.345599E+09 | 1.14 | 349.69 | 1.17 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.216539E+09 | 0.86 | 242.76 | 10-JAN-23:10 | 1.06 |
| February | 0.111074E+09 | 0.70 | 184.88 | 27-FEB-15:30 | 1.20 |
| March | 59285149.20 | 0.47 | 164.11 | 05-MAR-01:10 | 1.06 |
| April | 42512101.34 | 0.41 | 218.60 | 06-APR-16:10 | 1.19 |
| May | 0.104824E+09 | 0.56 | 311.79 | 19-MAY-15:10 | 1.16 |
| June | 0.264372E+09 | 0.98 | 355.47 | 29-JUN-14:30 | 1.16 |
| July | 0.432633E+09 | 1.15 | 429.26 | 17-JUL-16:04 | 1.14 |
| August | 0.399215E+09 | 1.13 | 440.86 | 10-AUG-15:10 | 1.14 |
| September | 0.250930E+09 | 0.78 | 472.35 | 02-SEP-15:10 | 1.13 |
| October | 95279180.80 | 0.49 | 374.10 | 18-OCT-14:10 | 1.16 |
| November | 55421560.64 | 0.42 | 144.80 | 27-NOV-05:00 | 1.06 |
| December | 0.145474E+09 | 0.82 | 208.91 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.217756E+10 | 0.73 | |||
| Minimum of Months | 42512101.34 | 0.41 | 144.80 | 1.06 | |
| Maximum of Months | 0.432633E+09 | 1.15 | 472.35 | 1.20 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.216287E+09 | 0.86 | 242.67 | 10-JAN-23:10 | 1.06 |
| February | 0.111189E+09 | 0.70 | 186.38 | 26-FEB-13:50 | 1.20 |
| March | 59181857.45 | 0.47 | 164.12 | 05-MAR-01:10 | 1.06 |
| April | 43372218.75 | 0.41 | 220.34 | 06-APR-16:10 | 1.19 |
| May | 0.104942E+09 | 0.56 | 312.05 | 19-MAY-15:10 | 1.16 |
| June | 0.265332E+09 | 0.98 | 356.12 | 29-JUN-14:30 | 1.16 |
| July | 0.433477E+09 | 1.15 | 428.77 | 17-JUL-16:04 | 1.14 |
| August | 0.400149E+09 | 1.13 | 441.12 | 10-AUG-15:10 | 1.14 |
| September | 0.251463E+09 | 0.78 | 472.38 | 02-SEP-15:10 | 1.13 |
| October | 95819970.54 | 0.49 | 374.61 | 18-OCT-14:10 | 1.16 |
| November | 55615467.52 | 0.42 | 145.54 | 03-NOV-14:10 | 1.20 |
| December | 0.145395E+09 | 0.82 | 208.85 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.218222E+10 | 0.73 | |||
| Minimum of Months | 43372218.75 | 0.41 | 145.54 | 1.06 | |
| Maximum of Months | 0.433477E+09 | 1.15 | 472.38 | 1.20 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.73 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.73 | 40.01 | 01-JAN-00:10 | 0.72 |
| February | 96801429.15 | 0.73 | 40.01 | 01-FEB-00:10 | 0.73 |
| March | 0.107173E+09 | 0.72 | 40.01 | 01-MAR-00:10 | 0.72 |
| April | 0.103716E+09 | 0.72 | 40.01 | 01-APR-00:10 | 0.72 |
| May | 0.107173E+09 | 0.72 | 40.01 | 01-MAY-00:10 | 0.72 |
| June | 0.103716E+09 | 0.72 | 40.01 | 01-JUN-00:10 | 0.72 |
| July | 0.107173E+09 | 0.72 | 40.01 | 01-JUL-00:10 | 0.72 |
| August | 0.107173E+09 | 0.72 | 40.01 | 01-AUG-00:10 | 0.72 |
| September | 0.103716E+09 | 0.72 | 40.01 | 01-SEP-00:10 | 0.72 |
| October | 0.107173E+09 | 0.72 | 40.01 | 01-OCT-00:10 | 0.72 |
| November | 0.103716E+09 | 0.72 | 40.01 | 01-NOV-00:10 | 0.72 |
| December | 0.107173E+09 | 0.73 | 40.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.126188E+10 | 0.72 | |||
| Minimum of Months | 96801429.15 | 0.72 | 40.01 | 0.72 | |
| Maximum of Months | 0.107173E+09 | 0.73 | 40.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.307089E+09 | 1.01 | 266.39 | 10-JAN-23:10 | 1.06 |
| February | 0.182849E+09 | 0.94 | 205.62 | 04-FEB-03:00 | 1.06 |
| March | 0.152395E+09 | 0.89 | 205.74 | 05-MAR-01:10 | 1.06 |
| April | 96940256.90 | 0.79 | 221.41 | 06-APR-16:10 | 1.17 |
| May | 0.112929E+09 | 0.70 | 287.86 | 19-MAY-16:10 | 1.15 |
| June | 0.169539E+09 | 0.74 | 314.27 | 28-JUN-17:15 | 1.14 |
| July | 0.276638E+09 | 0.88 | 410.25 | 17-JUL-16:10 | 1.11 |
| August | 0.239472E+09 | 0.83 | 389.76 | 06-AUG-16:02 | 1.12 |
| September | 0.154038E+09 | 0.77 | 393.99 | 02-SEP-15:20 | 1.12 |
| October | 84983578.40 | 0.72 | 263.04 | 18-OCT-15:20 | 1.16 |
| November | 0.130468E+09 | 0.83 | 189.54 | 27-NOV-05:00 | 1.06 |
| December | 0.238231E+09 | 1.01 | 235.90 | 31-DEC-08:00 | 1.06 |
| Annual Sum or Average | 0.214557E+10 | 0.84 | |||
| Minimum of Months | 84983578.40 | 0.70 | 189.54 | 1.06 | |
| Maximum of Months | 0.307089E+09 | 1.01 | 410.25 | 1.17 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.353002E+09 | 1.05 | 266.97 | 10-JAN-23:10 | 1.06 |
| February | 0.217366E+09 | 1.00 | 206.11 | 04-FEB-03:00 | 1.06 |
| March | 0.178052E+09 | 0.97 | 206.24 | 05-MAR-01:10 | 1.06 |
| April | 84337833.92 | 0.76 | 129.96 | 29-APR-05:00 | 1.05 |
| May | 92205603.27 | 0.66 | 240.99 | 19-MAY-17:30 | 1.16 |
| June | 0.140446E+09 | 0.72 | 297.47 | 28-JUN-18:00 | 1.15 |
| July | 0.230635E+09 | 0.87 | 362.92 | 17-JUL-17:30 | 1.12 |
| August | 0.172361E+09 | 0.78 | 335.24 | 06-AUG-16:30 | 1.13 |
| September | 97935566.29 | 0.70 | 290.77 | 02-SEP-17:00 | 1.14 |
| October | 74918299.82 | 0.75 | 112.55 | 10-OCT-06:40 | 1.05 |
| November | 0.167739E+09 | 1.01 | 192.48 | 27-NOV-05:00 | 1.06 |
| December | 0.282087E+09 | 1.05 | 236.49 | 31-DEC-08:02 | 1.06 |
| Annual Sum or Average | 0.209109E+10 | 0.86 | |||
| Minimum of Months | 74918299.82 | 0.66 | 112.55 | 1.05 | |
| Maximum of Months | 0.353002E+09 | 1.05 | 362.92 | 1.16 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.297933E+09 | 1.01 | 259.64 | 10-JAN-23:10 | 1.06 |
| February | 0.176707E+09 | 0.94 | 200.62 | 04-FEB-03:00 | 1.06 |
| March | 0.144770E+09 | 0.88 | 200.68 | 05-MAR-01:10 | 1.06 |
| April | 93061607.71 | 0.79 | 169.49 | 06-APR-15:20 | 1.18 |
| May | 0.104607E+09 | 0.71 | 245.72 | 19-MAY-15:10 | 1.14 |
| June | 0.172574E+09 | 0.78 | 291.90 | 29-JUN-14:30 | 1.13 |
| July | 0.283107E+09 | 0.91 | 350.09 | 25-JUL-13:00 | 1.11 |
| August | 0.244335E+09 | 0.85 | 345.31 | 10-AUG-14:40 | 1.11 |
| September | 0.149155E+09 | 0.77 | 359.81 | 02-SEP-14:00 | 1.10 |
| October | 79494045.98 | 0.72 | 229.78 | 18-OCT-14:10 | 1.16 |
| November | 0.126331E+09 | 0.82 | 185.07 | 27-NOV-05:00 | 1.06 |
| December | 0.231884E+09 | 1.01 | 230.01 | 31-DEC-08:00 | 1.06 |
| Annual Sum or Average | 0.210396E+10 | 0.85 | |||
| Minimum of Months | 79494045.98 | 0.71 | 169.49 | 1.06 | |
| Maximum of Months | 0.297933E+09 | 1.01 | 359.81 | 1.18 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.342207E+09 | 1.05 | 259.80 | 10-JAN-23:10 | 1.06 |
| February | 0.210821E+09 | 1.02 | 200.79 | 04-FEB-03:00 | 1.06 |
| March | 0.170428E+09 | 0.97 | 200.88 | 05-MAR-01:10 | 1.06 |
| April | 76752183.15 | 0.71 | 128.58 | 29-APR-05:00 | 1.05 |
| May | 83656697.03 | 0.64 | 183.98 | 20-MAY-16:10 | 1.16 |
| June | 0.143565E+09 | 0.76 | 241.28 | 29-JUN-15:10 | 1.14 |
| July | 0.238303E+09 | 0.90 | 294.60 | 17-JUL-16:10 | 1.12 |
| August | 0.176956E+09 | 0.82 | 277.92 | 06-AUG-16:02 | 1.13 |
| September | 91049698.49 | 0.67 | 235.21 | 03-SEP-16:02 | 1.14 |
| October | 69857396.23 | 0.72 | 109.58 | 10-OCT-06:35 | 1.05 |
| November | 0.163891E+09 | 1.03 | 187.55 | 27-NOV-05:00 | 1.06 |
| December | 0.274399E+09 | 1.05 | 230.28 | 31-DEC-08:07 | 1.06 |
| Annual Sum or Average | 0.204189E+10 | 0.86 | |||
| Minimum of Months | 69857396.23 | 0.64 | 109.58 | 1.05 | |
| Maximum of Months | 0.342207E+09 | 1.05 | 294.60 | 1.16 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.249949E+09 | 1.05 | 192.54 | 10-JAN-23:10 | 1.06 |
| February | 0.152044E+09 | 1.01 | 149.26 | 04-FEB-03:00 | 1.06 |
| March | 0.122249E+09 | 0.97 | 149.06 | 05-MAR-01:10 | 1.06 |
| April | 51157403.05 | 0.67 | 91.68 | 29-APR-05:00 | 1.05 |
| May | 57788339.12 | 0.60 | 154.65 | 20-MAY-16:08 | 1.17 |
| June | 0.102639E+09 | 0.70 | 188.59 | 29-JUN-15:10 | 1.16 |
| July | 0.178588E+09 | 0.91 | 240.32 | 17-JUL-16:04 | 1.14 |
| August | 0.131541E+09 | 0.82 | 224.65 | 06-AUG-16:17 | 1.14 |
| September | 68277216.85 | 0.65 | 193.15 | 03-SEP-16:02 | 1.15 |
| October | 44904608.24 | 0.66 | 77.36 | 10-OCT-06:00 | 1.05 |
| November | 0.113763E+09 | 0.99 | 136.53 | 27-NOV-05:00 | 1.06 |
| December | 0.197521E+09 | 1.05 | 170.39 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.147042E+10 | 0.84 | |||
| Minimum of Months | 44904608.24 | 0.60 | 77.36 | 1.05 | |
| Maximum of Months | 0.249949E+09 | 1.05 | 240.32 | 1.17 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.249623E+09 | 1.05 | 192.35 | 10-JAN-23:10 | 1.06 |
| February | 0.151899E+09 | 1.01 | 149.12 | 04-FEB-03:00 | 1.06 |
| March | 0.122082E+09 | 0.97 | 148.92 | 05-MAR-01:10 | 1.06 |
| April | 51064001.56 | 0.67 | 91.74 | 29-APR-05:00 | 1.05 |
| May | 57915986.60 | 0.60 | 154.38 | 20-MAY-16:08 | 1.17 |
| June | 0.103382E+09 | 0.71 | 188.61 | 29-JUN-15:10 | 1.16 |
| July | 0.179307E+09 | 0.91 | 239.33 | 17-JUL-16:04 | 1.14 |
| August | 0.132285E+09 | 0.82 | 223.89 | 06-AUG-16:02 | 1.14 |
| September | 68284017.12 | 0.65 | 192.34 | 03-SEP-16:02 | 1.15 |
| October | 44920672.71 | 0.66 | 77.28 | 10-OCT-06:00 | 1.05 |
| November | 0.113713E+09 | 0.99 | 136.39 | 27-NOV-05:00 | 1.06 |
| December | 0.197312E+09 | 1.05 | 170.22 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.147179E+10 | 0.84 | |||
| Minimum of Months | 44920672.71 | 0.60 | 77.28 | 1.05 | |
| Maximum of Months | 0.249623E+09 | 1.05 | 239.33 | 1.17 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.206888E+09 | 0.97 | 192.18 | 10-JAN-23:10 | 1.06 |
| February | 0.120366E+09 | 0.89 | 148.87 | 04-FEB-03:00 | 1.06 |
| March | 98082394.82 | 0.85 | 148.59 | 05-MAR-01:10 | 1.06 |
| April | 61715495.26 | 0.73 | 147.49 | 06-APR-16:10 | 1.18 |
| May | 76187781.68 | 0.66 | 206.13 | 19-MAY-15:10 | 1.15 |
| June | 0.131446E+09 | 0.74 | 236.45 | 29-JUN-14:30 | 1.14 |
| July | 0.224753E+09 | 0.92 | 291.43 | 17-JUL-16:10 | 1.12 |
| August | 0.199725E+09 | 0.87 | 292.74 | 10-AUG-14:50 | 1.12 |
| September | 0.125840E+09 | 0.76 | 307.26 | 02-SEP-14:10 | 1.11 |
| October | 58279947.40 | 0.62 | 211.78 | 18-OCT-14:20 | 1.16 |
| November | 81447929.49 | 0.74 | 133.52 | 27-NOV-05:00 | 1.06 |
| December | 0.156543E+09 | 0.95 | 169.80 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.154127E+10 | 0.81 | |||
| Minimum of Months | 58279947.40 | 0.62 | 133.52 | 1.06 | |
| Maximum of Months | 0.224753E+09 | 0.97 | 307.26 | 1.18 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.206640E+09 | 0.97 | 192.00 | 10-JAN-23:10 | 1.06 |
| February | 0.120411E+09 | 0.89 | 148.74 | 04-FEB-03:00 | 1.06 |
| March | 98204990.68 | 0.85 | 148.46 | 05-MAR-01:10 | 1.06 |
| April | 62239535.64 | 0.74 | 147.45 | 06-APR-16:10 | 1.18 |
| May | 76529880.81 | 0.67 | 206.55 | 19-MAY-15:10 | 1.15 |
| June | 0.132265E+09 | 0.74 | 237.06 | 29-JUN-14:30 | 1.14 |
| July | 0.225460E+09 | 0.92 | 290.42 | 17-JUL-16:10 | 1.12 |
| August | 0.200431E+09 | 0.87 | 292.84 | 10-AUG-14:50 | 1.12 |
| September | 0.126172E+09 | 0.76 | 307.80 | 02-SEP-14:10 | 1.11 |
| October | 58584898.31 | 0.62 | 212.47 | 18-OCT-14:10 | 1.16 |
| November | 81562851.43 | 0.74 | 133.40 | 27-NOV-05:00 | 1.06 |
| December | 0.156401E+09 | 0.95 | 169.65 | 31-DEC-07:00 | 1.06 |
| Annual Sum or Average | 0.154490E+10 | 0.81 | |||
| Minimum of Months | 58584898.31 | 0.62 | 133.40 | 1.06 | |
| Maximum of Months | 0.225460E+09 | 0.97 | 307.80 | 1.18 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.73 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.73 | 20.01 | 01-JAN-00:10 | 0.72 |
| February | 48400714.57 | 0.73 | 20.01 | 01-FEB-00:10 | 0.73 |
| March | 53586505.42 | 0.72 | 20.01 | 01-MAR-00:10 | 0.72 |
| April | 51857908.47 | 0.72 | 20.01 | 01-APR-00:10 | 0.72 |
| May | 53586505.42 | 0.72 | 20.01 | 01-MAY-00:10 | 0.72 |
| June | 51857908.47 | 0.72 | 20.01 | 01-JUN-00:10 | 0.72 |
| July | 53586505.42 | 0.72 | 20.01 | 01-JUL-00:10 | 0.72 |
| August | 53586505.42 | 0.72 | 20.01 | 01-AUG-00:10 | 0.72 |
| September | 51857908.47 | 0.72 | 20.01 | 01-SEP-00:10 | 0.72 |
| October | 53586505.42 | 0.72 | 20.01 | 01-OCT-00:10 | 0.72 |
| November | 51857908.47 | 0.72 | 20.01 | 01-NOV-00:10 | 0.72 |
| December | 53586505.42 | 0.73 | 20.01 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.630938E+09 | 0.72 | |||
| Minimum of Months | 48400714.57 | 0.72 | 20.01 | 0.72 | |
| Maximum of Months | 53586505.42 | 0.73 | 20.01 | 0.73 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.217614E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.129092E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.113947E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 59483287.12 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 72028052.86 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.306843E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.807985E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.723265E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.439159E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 88586517.83 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 59640016.72 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.154480E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.317212E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 59483287.12 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.807985E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.257885E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.170324E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.153257E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 81675606.23 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 55455278.35 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.225064E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.637655E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.477122E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.231715E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 24746745.35 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 97311211.54 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.192581E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.260479E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 24746745.35 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.637655E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.127231E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.115052E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.127231E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.123854E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.131255E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.152781E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.178506E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.179864E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.151357E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.138518E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.124182E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.127231E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.167706E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.115052E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.179864E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.250894E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.166166E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.148096E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 78006295.93 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 49308593.30 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.245311E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.674933E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.504881E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.223736E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 23168006.18 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 95615805.36 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.188209E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.264833E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 23168006.18 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.674933E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.179939E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.117421E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.103195E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 51357372.14 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 32842191.55 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.185076E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.534338E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.401958E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.191529E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 11439866.37 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 62589215.10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.131956E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.200364E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 11439866.37 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.534338E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.179779E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.117341E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.103061E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 51269466.60 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 32638478.46 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.186984E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.536817E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.404554E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.191627E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 11410899.15 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 62589657.83 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.131884E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.200996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 11410899.15 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.536817E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.142646E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 80027781.62 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 66930498.98 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 31993487.40 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 48663533.81 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.275153E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.713945E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.665122E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.424300E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.111742E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 32068728.46 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 96911936.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.268950E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 31993487.40 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.713945E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.154003E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 87974855.75 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 73209501.34 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 34115713.89 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 53815102.97 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.308971E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.789712E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.733442E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.471789E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.121890E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 35708354.82 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.106702E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.297133E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 34115713.89 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.789712E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.370655E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.220182E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.134226E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.168446E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.508327E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.136172E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.227130E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.198525E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.115794E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.319252E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.116432E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.269557E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.888328E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.116432E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.227130E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.457061E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.266925E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.199988E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 62643862.38 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.337325E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.112904E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.189581E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.142620E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.632126E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 51471422.77 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.181996E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.351282E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.699186E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 51471422.77 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.189581E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.359846E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.215016E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.123537E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.180080E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.478183E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.142532E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.234817E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.205543E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.115322E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.312430E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.112763E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.263190E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.902720E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.112763E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.234817E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.443924E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.259548E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.190949E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 55683658.33 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.303201E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.119137E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.197652E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.149718E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.613326E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 47661463.10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.178620E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.342939E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.710092E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 47661463.10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197652E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.296038E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.168231E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.119545E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 24294436.37 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.233941E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.888717E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.148361E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.113689E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.507862E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 23388783.47 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.103544E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.220362E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.520643E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 23388783.47 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.148361E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.295738E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.168118E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.119381E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 24224385.62 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.233919E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.893120E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.148742E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.114141E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.508810E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 23383305.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.103584E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.220238E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.521935E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 23383305.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.148742E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.216539E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.147371E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 68276208.06 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.141057E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.408018E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.112611E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.186150E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.170596E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.107136E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.388235E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 82263403.03 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.145474E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.736215E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 68276208.06 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186150E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.216287E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.147988E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 68341149.62 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.144607E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.408424E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.113018E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.186511E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.170992E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.107358E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.390395E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 82858483.97 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.145395E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.738309E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 68341149.62 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186511E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.307089E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.206793E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.174601E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.191398E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.330686E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.706049E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.119414E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.101882E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.592440E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.196062E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.140379E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.238231E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.529669E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.140379E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.119414E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.353002E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.217366E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.178052E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.101791E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.232646E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.583578E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.996038E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.731719E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.334101E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 81873364.23 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.167739E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.282087E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.425999E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 81873364.23 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.996038E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.297933E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.197450E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.162073E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.183349E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.300432E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.720430E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.122037E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.103976E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.575964E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.180352E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.133456E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.231884E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.524345E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133456E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.122037E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.342207E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.210821E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.170428E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 82753448.26 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.202031E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.597725E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.102731E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.751807E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.312144E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 73022156.90 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.163891E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.274399E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.420854E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 73022156.90 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.102731E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.249949E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.152044E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.122249E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 52937754.57 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.145724E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.432637E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.771567E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.561800E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.246395E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 46529117.93 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.113763E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.197521E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.309312E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 46529117.93 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.771567E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.249623E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.151899E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.122082E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 52869863.43 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.146068E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.435777E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.774629E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.565013E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.246618E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 46610921.13 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.113713E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.197312E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.310222E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 46610921.13 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.774629E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.207103E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.143751E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.117508E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.130457E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.233742E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.554805E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.970509E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.853298E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.506030E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.161692E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 93666954.49 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.156543E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.412911E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 93666954.49 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.970509E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.206908E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.144224E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.118398E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.132655E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.234963E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.558242E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.973513E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.856317E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.507453E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.162946E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 94063491.91 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.156401E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.414608E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 94063491.91 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.973513E+09 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.217614E+09 | 0.00 | 0.452894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.129092E+09 | 0.00 | 0.268665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.113947E+09 | 0.00 | 0.237145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 59317669.98 | 617425.41 | 0.123342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 42303562.10 | 0.110944E+09 | 0.689498E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 71972568.16 | 0.882453E+09 | 8777289.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.187307E+09 | 0.231771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.168844E+09 | 0.207112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.103382E+09 | 0.127505E+10 | 24208465.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 27910594.54 | 0.229975E+09 | 0.182875E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 59612348.22 | 103011.26 | 0.124046E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.154480E+09 | 0.00 | 0.321502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.133578E+10 | 0.688797E+10 | 0.161813E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27910594.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.217614E+09 | 0.231771E+10 | 0.452894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.257885E+09 | 0.00 | 0.543750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.170324E+09 | 0.00 | 0.359128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.153257E+09 | 0.00 | 0.323142E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81675606.23 | 0.00 | 0.172213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 44755463.61 | 39553411.61 | 0.874290E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 52870716.79 | 0.644490E+09 | 11212025.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.147642E+09 | 0.182092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.111101E+09 | 0.135071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 57985192.28 | 0.650739E+09 | 0.115102E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 24088895.94 | 2442849.84 | 0.503552E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 97311211.54 | 0.00 | 0.205181E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.192581E+09 | 0.00 | 0.406058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.139148E+10 | 0.450885E+10 | 0.215989E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 24088895.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.257885E+09 | 0.182092E+10 | 0.543750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.127231E+10 | 0.00 | 0.292735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.114919E+10 | 4970531.76 | 0.131797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.127231E+10 | 0.00 | 0.818768E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.123127E+10 | 27323071.40 | 0.141606E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.127231E+10 | 0.153474E+09 | 0.137523E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.123127E+10 | 0.114834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.127231E+10 | 0.198228E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.127231E+10 | 0.204878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.123127E+10 | 0.111157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.127231E+10 | 0.434906E+09 | 9526477.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.123127E+10 | 39493943.42 | 0.381762E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.127231E+10 | 0.00 | 0.145231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.149805E+11 | 0.695113E+10 | 0.718682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.114919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.127231E+10 | 0.204878E+10 | 0.292735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.250894E+09 | 0.00 | 0.539900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.166166E+09 | 0.00 | 0.357574E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.148096E+09 | 0.00 | 0.318688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 78006295.93 | 0.00 | 0.167862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 42729157.29 | 24093595.36 | 0.876328E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 57629782.59 | 0.706580E+09 | 11817733.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.156452E+09 | 0.194161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.117680E+09 | 0.143809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 55594796.75 | 0.630948E+09 | 0.102421E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 22983744.26 | 681059.87 | 0.493342E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 95615805.36 | 0.00 | 0.205756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.188209E+09 | 0.00 | 0.405009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138006E+10 | 0.474200E+10 | 0.214318E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22983744.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.250894E+09 | 0.194161E+10 | 0.539900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.179939E+09 | 0.00 | 0.394418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.117421E+09 | 0.00 | 0.257382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103195E+09 | 0.00 | 0.226198E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51357372.14 | 0.00 | 0.112573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 27322655.78 | 20289190.73 | 0.561749E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 43166121.42 | 0.531612E+09 | 468285.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.123830E+09 | 0.152970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 93717743.08 | 0.113997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 45978576.06 | 0.546784E+09 | 42512296.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 11388005.18 | 192172.49 | 0.249262E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 62589215.10 | 0.00 | 0.137193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.131956E+09 | 0.00 | 0.289241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.991859E+09 | 0.376855E+10 | 0.150240E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11388005.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.179939E+09 | 0.152970E+10 | 0.394418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.179779E+09 | 0.00 | 0.394245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.117341E+09 | 0.00 | 0.257322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103061E+09 | 0.00 | 0.226007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51269466.60 | 0.00 | 0.112431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 27295528.21 | 19626680.53 | 0.562621E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 43613283.46 | 0.537245E+09 | 477263.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.124409E+09 | 0.153716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 94329590.11 | 0.114764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 45973777.53 | 0.547161E+09 | 41742470.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 11370378.24 | 150260.65 | 0.249066E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 62589657.83 | 0.00 | 0.137256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.131884E+09 | 0.00 | 0.289215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.992916E+09 | 0.378898E+10 | 0.150187E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11370378.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.179779E+09 | 0.153716E+10 | 0.394245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.142646E+09 | 0.00 | 0.306137E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 80021122.55 | 24640.21 | 0.171731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 66930498.98 | 0.00 | 0.143641E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 31993487.40 | 0.00 | 0.686620E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 25625654.90 | 85931662.57 | 0.397618E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 64290261.57 | 0.793894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.165666E+09 | 0.205430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.155481E+09 | 0.191168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 99185343.73 | 0.123964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28830592.11 | 0.314866E+09 | 58150827.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 31064567.66 | 3754087.46 | 0.659906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 96911936.55 | 0.00 | 0.207985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.988648E+09 | 0.640410E+10 | 0.100972E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 25625654.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.165666E+09 | 0.205430E+10 | 0.306137E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.154003E+09 | 0.00 | 0.330157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 87974855.75 | 0.00 | 0.188603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 73209501.34 | 0.00 | 0.156948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 34115713.89 | 0.00 | 0.731382E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 28014355.50 | 96400894.33 | 0.430062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 72256947.15 | 0.893626E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.183391E+09 | 0.228062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.171561E+09 | 0.211485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.110356E+09 | 0.138224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 31320637.98 | 0.344086E+09 | 59790010.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 34084925.94 | 6075994.30 | 0.719770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.106702E+09 | 0.00 | 0.228751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.108699E+10 | 0.711789E+10 | 0.109856E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28014355.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.183391E+09 | 0.228062E+10 | 0.330157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.370655E+09 | 0.00 | 0.748480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.195431E+09 | 93045864.31 | 0.378805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.128422E+09 | 21686752.83 | 0.255614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65304818.82 | 0.390112E+09 | 0.661306E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.141176E+09 | 0.139901E+10 | 0.541067E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.319649E+09 | 0.396294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.527551E+09 | 0.653764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.464104E+09 | 0.570102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.273130E+09 | 0.335778E+10 | 61992208.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88625527.46 | 0.877191E+09 | 0.322322E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.109439E+09 | 26183019.33 | 0.216544E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.269557E+09 | 0.00 | 0.544329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.295304E+10 | 0.223666E+11 | 0.230244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 65304818.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.527551E+09 | 0.653764E+10 | 0.748480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.457061E+09 | 0.00 | 0.929426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.266925E+09 | 0.00 | 0.542787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.199988E+09 | 0.00 | 0.406672E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 57258862.65 | 20092561.50 | 0.112975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.105622E+09 | 0.879258E+09 | 0.682997E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.264886E+09 | 0.327791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.440179E+09 | 0.543591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.333015E+09 | 0.405623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.153758E+09 | 0.179164E+10 | 0.177228E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 44042887.62 | 27701799.88 | 0.848045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.181996E+09 | 0.00 | 0.370085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.351282E+09 | 0.00 | 0.714326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.285601E+10 | 0.154887E+11 | 0.324710E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44042887.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.457061E+09 | 0.543591E+10 | 0.929426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.359846E+09 | 0.00 | 0.740032E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.190728E+09 | 91254927.92 | 0.376410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.121041E+09 | 9307647.85 | 0.247299E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 67815129.66 | 0.424652E+09 | 0.666263E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.133991E+09 | 0.131333E+10 | 0.551381E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.334658E+09 | 0.417291E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.545938E+09 | 0.681593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.480864E+09 | 0.594623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.271904E+09 | 0.335941E+10 | 55145854.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 86357326.02 | 0.860646E+09 | 0.311071E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107300E+09 | 20471679.34 | 0.217126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.263190E+09 | 0.00 | 0.541257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.296363E+10 | 0.230141E+11 | 0.228051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 67815129.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.545938E+09 | 0.681593E+10 | 0.740032E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.443924E+09 | 0.00 | 0.921135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.259548E+09 | 0.00 | 0.538557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190949E+09 | 0.00 | 0.396215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 53756277.27 | 7161290.39 | 0.110277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 97235842.57 | 0.781577E+09 | 0.690269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.279586E+09 | 0.347821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.459447E+09 | 0.571404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349935E+09 | 0.428595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.148525E+09 | 0.174534E+10 | 0.156145E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 41522899.88 | 22838314.67 | 0.821495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.178620E+09 | 0.00 | 0.370634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.342939E+09 | 0.00 | 0.711593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.284599E+10 | 0.160351E+11 | 0.321520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41522899.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.459447E+09 | 0.571404E+10 | 0.921135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.296038E+09 | 0.00 | 0.624995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.168231E+09 | 0.00 | 0.355169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119545E+09 | 0.00 | 0.252384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 24108587.20 | 688670.73 | 0.507737E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 67151701.90 | 0.631759E+09 | 0.324966E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.208504E+09 | 0.257995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.344711E+09 | 0.426033E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.265758E+09 | 0.323691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.119607E+09 | 0.145800E+10 | 37055198.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 17558957.79 | 21707955.73 | 0.331969E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103544E+09 | 0.00 | 0.218602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.220362E+09 | 0.00 | 0.465229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195512E+10 | 0.121893E+11 | 0.203655E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17558957.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.344711E+09 | 0.426033E+10 | 0.624995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.295738E+09 | 0.00 | 0.624631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.168118E+09 | 0.00 | 0.355085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119381E+09 | 0.00 | 0.252147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 24003185.99 | 819784.56 | 0.505494E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 67222709.18 | 0.631381E+09 | 0.327197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.209541E+09 | 0.259311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345599E+09 | 0.427201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.266822E+09 | 0.325037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.119806E+09 | 0.146084E+10 | 36387025.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 17561594.91 | 21677147.23 | 0.332222E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103584E+09 | 0.00 | 0.218782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.220238E+09 | 0.00 | 0.465168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195762E+10 | 0.122302E+11 | 0.203594E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17561594.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345599E+09 | 0.427201E+10 | 0.624631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.216539E+09 | 0.00 | 0.451385E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.111074E+09 | 0.137073E+09 | 0.207562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59285149.20 | 33722789.66 | 0.117643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 42512101.34 | 0.371861E+09 | 0.237701E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.104824E+09 | 0.115421E+10 | 0.217713E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.264372E+09 | 0.327893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.432633E+09 | 0.536894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.399215E+09 | 0.491312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.250930E+09 | 0.312617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 95279180.80 | 0.111675E+10 | 62774355.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 55421560.64 | 0.100911E+09 | 0.978762E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.145474E+09 | 0.00 | 0.303247E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.217756E+10 | 0.196017E+11 | 0.122953E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42512101.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.432633E+09 | 0.536894E+10 | 0.451385E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.216287E+09 | 0.00 | 0.451042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.111189E+09 | 0.139000E+09 | 0.207555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59181857.45 | 34354834.70 | 0.117363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 43372218.75 | 0.382097E+09 | 0.238030E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.104942E+09 | 0.115536E+10 | 0.218321E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.265332E+09 | 0.329139E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.433477E+09 | 0.538047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.400149E+09 | 0.492554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.251463E+09 | 0.313298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 95819970.54 | 0.112302E+10 | 63449961.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 55615467.52 | 0.102437E+09 | 0.980560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.145395E+09 | 0.00 | 0.303203E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.218222E+10 | 0.196666E+11 | 0.122920E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 43372218.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.433477E+09 | 0.538047E+10 | 0.451042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.307089E+09 | 0.00 | 0.612833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.182849E+09 | 90581637.23 | 0.349752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.152395E+09 | 83466315.83 | 0.290075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96940256.90 | 0.359786E+09 | 0.133967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.112929E+09 | 0.832357E+09 | 0.897416E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.169539E+09 | 0.204611E+10 | 0.107663E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.276638E+09 | 0.343737E+10 | 5264845.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.239472E+09 | 0.292052E+10 | 54560798.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.154038E+09 | 0.166436E+10 | 0.412222E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 84983578.40 | 0.424039E+09 | 0.997441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.130468E+09 | 37307462.88 | 0.254125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.238231E+09 | 0.00 | 0.475418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.214557E+10 | 0.118959E+11 | 0.236363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 84983578.40 | 0.00 | 5264845.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.307089E+09 | 0.343737E+10 | 0.612833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.353002E+09 | 0.00 | 0.707042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.217366E+09 | 0.00 | 0.435370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.178052E+09 | 0.00 | 0.356627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 84337833.92 | 65712987.68 | 0.157896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 92205603.27 | 0.534220E+09 | 0.970940E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.140446E+09 | 0.168255E+10 | 99985792.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.230635E+09 | 0.284893E+10 | 4670851.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.172361E+09 | 0.206758E+10 | 56370365.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 97935566.29 | 0.880400E+09 | 0.533907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 74918299.82 | 26035066.89 | 0.145669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.167739E+09 | 0.00 | 0.335972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.282087E+09 | 0.00 | 0.565002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.209109E+10 | 0.810543E+10 | 0.287016E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 74918299.82 | 0.00 | 4670851.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.353002E+09 | 0.284893E+10 | 0.707042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.297933E+09 | 0.00 | 0.608193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.176707E+09 | 78562143.07 | 0.347305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144770E+09 | 64949776.37 | 0.284332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93061607.71 | 0.343582E+09 | 0.131835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.104607E+09 | 0.750847E+09 | 0.889047E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.172574E+09 | 0.210745E+10 | 0.100724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283107E+09 | 0.355492E+10 | 6268560.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.244335E+09 | 0.301370E+10 | 49681008.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.149155E+09 | 0.163177E+10 | 0.392359E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 79494045.98 | 0.385557E+09 | 0.973956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.126331E+09 | 26902954.23 | 0.253306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.231884E+09 | 0.00 | 0.473362E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.210396E+10 | 0.119582E+11 | 0.233954E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 79494045.98 | 0.00 | 6268560.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.297933E+09 | 0.355492E+10 | 0.608193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.342207E+09 | 0.00 | 0.702282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.210821E+09 | 0.00 | 0.432650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.170428E+09 | 0.00 | 0.349755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 76752183.15 | 22416455.93 | 0.153624E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 83656697.03 | 0.450301E+09 | 0.961621E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.143565E+09 | 0.173683E+10 | 97004203.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.238303E+09 | 0.297001E+10 | 6536046.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.176956E+09 | 0.214329E+10 | 50667719.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 91049698.49 | 0.826965E+09 | 0.499398E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 69857396.23 | 11783911.39 | 0.141319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.163891E+09 | 0.00 | 0.336340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.274399E+09 | 0.00 | 0.563126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.204189E+10 | 0.816160E+10 | 0.284062E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 69857396.23 | 0.00 | 6536046.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.342207E+09 | 0.297001E+10 | 0.702282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.249949E+09 | 0.00 | 0.518015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.152044E+09 | 0.00 | 0.315109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122249E+09 | 0.00 | 0.253359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51157403.05 | 6632255.04 | 0.104856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 57788339.12 | 0.333353E+09 | 0.631805E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.102639E+09 | 0.125145E+10 | 39353297.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.178588E+09 | 0.220856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.131541E+09 | 0.158947E+10 | 21596852.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 68277216.85 | 0.664115E+09 | 0.301436E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 44904608.24 | 6030289.53 | 0.920058E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113763E+09 | 0.00 | 0.235772E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.197521E+09 | 0.00 | 0.409358E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.147042E+10 | 0.605961E+10 | 0.202789E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44904608.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.249949E+09 | 0.220856E+10 | 0.518015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.249623E+09 | 0.00 | 0.517837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.151899E+09 | 0.00 | 0.315111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122082E+09 | 0.00 | 0.253256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51064001.56 | 6727497.95 | 0.104747E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 57915986.60 | 0.334198E+09 | 0.633657E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103382E+09 | 0.126096E+10 | 39496636.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.179307E+09 | 0.221828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.132285E+09 | 0.159927E+10 | 21296935.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 68284017.12 | 0.664998E+09 | 0.300487E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 44920672.71 | 6274183.22 | 0.920847E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113713E+09 | 0.00 | 0.235895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.197312E+09 | 0.00 | 0.409320E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.147179E+10 | 0.609071E+10 | 0.202774E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44920672.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.249623E+09 | 0.221828E+10 | 0.517837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.206888E+09 | 800780.38 | 0.425732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.120366E+09 | 88642080.58 | 0.232514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98082394.82 | 72940235.26 | 0.189224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 61715495.26 | 0.260707E+09 | 0.823926E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76187781.68 | 0.601780E+09 | 0.557884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.131446E+09 | 0.161555E+10 | 41795830.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.224753E+09 | 0.280106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.199725E+09 | 0.245771E+10 | 20833851.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.125840E+09 | 0.144922E+10 | 0.207565E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58279947.40 | 0.395111E+09 | 0.528943E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 81447929.49 | 46089052.82 | 0.159720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156543E+09 | 0.00 | 0.322239E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154127E+10 | 0.978961E+10 | 0.154752E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58279947.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.224753E+09 | 0.280106E+10 | 0.425732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.206640E+09 | 996687.92 | 0.425559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.120411E+09 | 90296113.03 | 0.232531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98204990.68 | 75848003.10 | 0.189140E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 62239535.64 | 0.267132E+09 | 0.824571E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76529880.81 | 0.605255E+09 | 0.559723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.132265E+09 | 0.162626E+10 | 42066197.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.225460E+09 | 0.281119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.200431E+09 | 0.246770E+10 | 20695440.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.126172E+09 | 0.145391E+10 | 0.207465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58584898.31 | 0.398838E+09 | 0.529522E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 81562851.43 | 47165328.46 | 0.159914E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156401E+09 | 0.00 | 0.322229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154490E+10 | 0.984460E+10 | 0.154778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58584898.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.225460E+09 | 0.281119E+10 | 0.425559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.217614E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.129092E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.113947E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 59317669.98 | 0.00 | 0.00 | 0.00 | 165617.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 42303562.10 | 0.00 | 0.00 | 0.00 | 29724490.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 71972568.16 | 0.00 | 0.00 | 0.00 | 0.234871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.187307E+09 | 0.00 | 0.00 | 0.00 | 0.620678E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.168844E+09 | 0.00 | 0.00 | 0.00 | 0.554420E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.103382E+09 | 0.00 | 0.00 | 0.00 | 0.335778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 27910594.54 | 0.00 | 0.00 | 0.00 | 60675923.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 59612348.22 | 0.00 | 0.00 | 0.00 | 27668.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.154480E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.133578E+10 | 0.00 | 0.00 | 0.00 | 0.183634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27910594.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.217614E+09 | 0.00 | 0.00 | 0.00 | 0.620678E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.257885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.170324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.153257E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81675606.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 44755463.61 | 0.00 | 0.00 | 0.00 | 10699814.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 52870716.79 | 0.00 | 0.00 | 0.00 | 0.172194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.147642E+09 | 0.00 | 0.00 | 0.00 | 0.490013E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.111101E+09 | 0.00 | 0.00 | 0.00 | 0.366020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 57985192.28 | 0.00 | 0.00 | 0.00 | 0.173730E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 24088895.94 | 0.00 | 0.00 | 0.00 | 657849.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 97311211.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.192581E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.139148E+10 | 0.00 | 0.00 | 0.00 | 0.121332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 24088895.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.257885E+09 | 0.00 | 0.00 | 0.00 | 0.490013E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.114919E+10 | 0.00 | 0.00 | 0.00 | 1332519.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.123127E+10 | 0.00 | 0.00 | 0.00 | 7270146.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 40236511.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.123127E+10 | 0.00 | 0.00 | 0.00 | 0.296536E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.512747E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.526327E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.123127E+10 | 0.00 | 0.00 | 0.00 | 0.282302E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.112866E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.123127E+10 | 0.00 | 0.00 | 0.00 | 10542864.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.149805E+11 | 0.00 | 0.00 | 0.00 | 0.179016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.114919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.127231E+10 | 0.00 | 0.00 | 0.00 | 0.526327E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.250894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.166166E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.148096E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 78006295.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 42729157.29 | 0.00 | 0.00 | 0.00 | 6579436.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 57629782.59 | 0.00 | 0.00 | 0.00 | 0.187681E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.156452E+09 | 0.00 | 0.00 | 0.00 | 0.518482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.117680E+09 | 0.00 | 0.00 | 0.00 | 0.387202E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 55594796.75 | 0.00 | 0.00 | 0.00 | 0.168141E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 22983744.26 | 0.00 | 0.00 | 0.00 | 184261.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 95615805.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.188209E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138006E+10 | 0.00 | 0.00 | 0.00 | 0.126827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22983744.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.250894E+09 | 0.00 | 0.00 | 0.00 | 0.518482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.179939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.117421E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103195E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51357372.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 27322655.78 | 0.00 | 0.00 | 0.00 | 5519535.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 43166121.42 | 0.00 | 0.00 | 0.00 | 0.141910E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.123830E+09 | 0.00 | 0.00 | 0.00 | 0.410508E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 93717743.08 | 0.00 | 0.00 | 0.00 | 0.308240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 45978576.06 | 0.00 | 0.00 | 0.00 | 0.145550E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 11388005.18 | 0.00 | 0.00 | 0.00 | 51861.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 62589215.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.131956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.991859E+09 | 0.00 | 0.00 | 0.00 | 0.101178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11388005.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.179939E+09 | 0.00 | 0.00 | 0.00 | 0.410508E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.179779E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.117341E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51269466.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 27295528.21 | 0.00 | 0.00 | 0.00 | 5342950.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 43613283.46 | 0.00 | 0.00 | 0.00 | 0.143371E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.124409E+09 | 0.00 | 0.00 | 0.00 | 0.412408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 94329590.11 | 0.00 | 0.00 | 0.00 | 0.310225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 45973777.53 | 0.00 | 0.00 | 0.00 | 0.145653E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 11370378.24 | 0.00 | 0.00 | 0.00 | 40520.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 62589657.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.131884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.992916E+09 | 0.00 | 0.00 | 0.00 | 0.101704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11370378.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.179779E+09 | 0.00 | 0.00 | 0.00 | 0.412408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.142646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 80021122.55 | 0.00 | 0.00 | 0.00 | 6659.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 66930498.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 31993487.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 25625654.90 | 0.00 | 0.00 | 0.00 | 23037878.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 64290261.57 | 0.00 | 0.00 | 0.00 | 0.210862E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.165666E+09 | 0.00 | 0.00 | 0.00 | 0.548278E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.155481E+09 | 0.00 | 0.00 | 0.00 | 0.509641E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 99185343.73 | 0.00 | 0.00 | 0.00 | 0.325115E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28830592.11 | 0.00 | 0.00 | 0.00 | 82911676.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 31064567.66 | 0.00 | 0.00 | 0.00 | 1004160.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 96911936.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.988648E+09 | 0.00 | 0.00 | 0.00 | 0.170086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 25625654.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.165666E+09 | 0.00 | 0.00 | 0.00 | 0.548278E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.154003E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 87974855.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 73209501.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 34115713.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 28014355.50 | 0.00 | 0.00 | 0.00 | 25800747.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 72256947.15 | 0.00 | 0.00 | 0.00 | 0.236714E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.183391E+09 | 0.00 | 0.00 | 0.00 | 0.606320E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.171561E+09 | 0.00 | 0.00 | 0.00 | 0.561881E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.110356E+09 | 0.00 | 0.00 | 0.00 | 0.361433E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 31320637.98 | 0.00 | 0.00 | 0.00 | 90569486.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 34084925.94 | 0.00 | 0.00 | 0.00 | 1623428.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.106702E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.108699E+10 | 0.00 | 0.00 | 0.00 | 0.188434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28014355.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.183391E+09 | 0.00 | 0.00 | 0.00 | 0.606320E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.370655E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.195431E+09 | 0.00 | 0.00 | 0.00 | 24751188.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.128422E+09 | 0.00 | 0.00 | 0.00 | 5803593.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65304818.82 | 0.00 | 0.00 | 0.00 | 0.103141E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.141176E+09 | 0.00 | 0.00 | 0.00 | 0.367152E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.319649E+09 | 0.00 | 0.00 | 0.00 | 0.104207E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.527551E+09 | 0.00 | 0.00 | 0.00 | 0.174375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.464104E+09 | 0.00 | 0.00 | 0.00 | 0.152115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.273130E+09 | 0.00 | 0.00 | 0.00 | 0.884807E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88625527.46 | 0.00 | 0.00 | 0.00 | 0.230626E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.109439E+09 | 0.00 | 0.00 | 0.00 | 6992928.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.269557E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.295304E+10 | 0.00 | 0.00 | 0.00 | 0.593024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 65304818.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.527551E+09 | 0.00 | 0.00 | 0.00 | 0.174375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.457061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.266925E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.199988E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 57258862.65 | 0.00 | 0.00 | 0.00 | 5384999.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.105622E+09 | 0.00 | 0.00 | 0.00 | 0.231703E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.264886E+09 | 0.00 | 0.00 | 0.00 | 0.864150E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.440179E+09 | 0.00 | 0.00 | 0.00 | 0.145563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.333015E+09 | 0.00 | 0.00 | 0.00 | 0.109318E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.153758E+09 | 0.00 | 0.00 | 0.00 | 0.478369E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 44042887.62 | 0.00 | 0.00 | 0.00 | 7428535.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.181996E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.351282E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.285601E+10 | 0.00 | 0.00 | 0.00 | 0.413585E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44042887.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.457061E+09 | 0.00 | 0.00 | 0.00 | 0.145563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.359846E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.190728E+09 | 0.00 | 0.00 | 0.00 | 24287185.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.121041E+09 | 0.00 | 0.00 | 0.00 | 2495541.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 67815129.66 | 0.00 | 0.00 | 0.00 | 0.112265E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.133991E+09 | 0.00 | 0.00 | 0.00 | 0.344192E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.334658E+09 | 0.00 | 0.00 | 0.00 | 0.109067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.545938E+09 | 0.00 | 0.00 | 0.00 | 0.180223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.480864E+09 | 0.00 | 0.00 | 0.00 | 0.157457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.271904E+09 | 0.00 | 0.00 | 0.00 | 0.881316E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 86357326.02 | 0.00 | 0.00 | 0.00 | 0.226073E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107300E+09 | 0.00 | 0.00 | 0.00 | 5463114.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.263190E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.296363E+10 | 0.00 | 0.00 | 0.00 | 0.606356E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 67815129.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.545938E+09 | 0.00 | 0.00 | 0.00 | 0.180223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.443924E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.259548E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190949E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 53756277.27 | 0.00 | 0.00 | 0.00 | 1927381.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 97235842.57 | 0.00 | 0.00 | 0.00 | 0.205965E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.279586E+09 | 0.00 | 0.00 | 0.00 | 0.911784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.459447E+09 | 0.00 | 0.00 | 0.00 | 0.151707E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349935E+09 | 0.00 | 0.00 | 0.00 | 0.114725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.148525E+09 | 0.00 | 0.00 | 0.00 | 0.464801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 41522899.88 | 0.00 | 0.00 | 0.00 | 6138563.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.178620E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.342939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.284599E+10 | 0.00 | 0.00 | 0.00 | 0.425494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41522899.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.459447E+09 | 0.00 | 0.00 | 0.00 | 0.151707E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.296038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.168231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119545E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 24108587.20 | 0.00 | 0.00 | 0.00 | 185849.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 67151701.90 | 0.00 | 0.00 | 0.00 | 0.166790E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.208504E+09 | 0.00 | 0.00 | 0.00 | 0.680213E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.344711E+09 | 0.00 | 0.00 | 0.00 | 0.113890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.265758E+09 | 0.00 | 0.00 | 0.00 | 0.871136E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.119607E+09 | 0.00 | 0.00 | 0.00 | 0.388256E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 17558957.79 | 0.00 | 0.00 | 0.00 | 5829825.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103544E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.220362E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195512E+10 | 0.00 | 0.00 | 0.00 | 0.325131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17558957.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.344711E+09 | 0.00 | 0.00 | 0.00 | 0.113890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.295738E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.168118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119381E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 24003185.99 | 0.00 | 0.00 | 0.00 | 221199.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 67222709.18 | 0.00 | 0.00 | 0.00 | 0.166696E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.209541E+09 | 0.00 | 0.00 | 0.00 | 0.683579E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345599E+09 | 0.00 | 0.00 | 0.00 | 0.114182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.266822E+09 | 0.00 | 0.00 | 0.00 | 0.874592E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.119806E+09 | 0.00 | 0.00 | 0.00 | 0.389004E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 17561594.91 | 0.00 | 0.00 | 0.00 | 5821710.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.220238E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.195762E+10 | 0.00 | 0.00 | 0.00 | 0.326173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17561594.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345599E+09 | 0.00 | 0.00 | 0.00 | 0.114182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.216539E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.111074E+09 | 0.00 | 0.00 | 0.00 | 36297681.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59285149.20 | 0.00 | 0.00 | 0.00 | 8991058.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 42512101.34 | 0.00 | 0.00 | 0.00 | 98544406.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.104824E+09 | 0.00 | 0.00 | 0.00 | 0.303194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.264372E+09 | 0.00 | 0.00 | 0.00 | 0.861736E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.432633E+09 | 0.00 | 0.00 | 0.00 | 0.142886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.399215E+09 | 0.00 | 0.00 | 0.00 | 0.130674E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.250930E+09 | 0.00 | 0.00 | 0.00 | 0.820429E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 95279180.80 | 0.00 | 0.00 | 0.00 | 0.292956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 55421560.64 | 0.00 | 0.00 | 0.00 | 26841842.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.145474E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.217756E+10 | 0.00 | 0.00 | 0.00 | 0.518460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42512101.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.432633E+09 | 0.00 | 0.00 | 0.00 | 0.142886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.216287E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.111189E+09 | 0.00 | 0.00 | 0.00 | 36798928.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59181857.45 | 0.00 | 0.00 | 0.00 | 9159292.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 43372218.75 | 0.00 | 0.00 | 0.00 | 0.101235E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.104942E+09 | 0.00 | 0.00 | 0.00 | 0.303482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.265332E+09 | 0.00 | 0.00 | 0.00 | 0.864853E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.433477E+09 | 0.00 | 0.00 | 0.00 | 0.143163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.400149E+09 | 0.00 | 0.00 | 0.00 | 0.130977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.251463E+09 | 0.00 | 0.00 | 0.00 | 0.822119E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 95819970.54 | 0.00 | 0.00 | 0.00 | 0.294575E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 55615467.52 | 0.00 | 0.00 | 0.00 | 27243016.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.145395E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.218222E+10 | 0.00 | 0.00 | 0.00 | 0.520087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 43372218.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.433477E+09 | 0.00 | 0.00 | 0.00 | 0.143163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.307089E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.182849E+09 | 0.00 | 0.00 | 0.00 | 23944136.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.152395E+09 | 0.00 | 0.00 | 0.00 | 22205602.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96940256.90 | 0.00 | 0.00 | 0.00 | 94458210.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.112929E+09 | 0.00 | 0.00 | 0.00 | 0.217757E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.169539E+09 | 0.00 | 0.00 | 0.00 | 0.536510E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.276638E+09 | 0.00 | 0.00 | 0.00 | 0.917506E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.239472E+09 | 0.00 | 0.00 | 0.00 | 0.779349E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.154038E+09 | 0.00 | 0.00 | 0.00 | 0.438402E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 84983578.40 | 0.00 | 0.00 | 0.00 | 0.111079E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.130468E+09 | 0.00 | 0.00 | 0.00 | 9911132.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.238231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.214557E+10 | 0.00 | 0.00 | 0.00 | 0.315112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 84983578.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.307089E+09 | 0.00 | 0.00 | 0.00 | 0.917506E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.353002E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.217366E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.178052E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 84337833.92 | 0.00 | 0.00 | 0.00 | 17453086.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 92205603.27 | 0.00 | 0.00 | 0.00 | 0.140441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.140446E+09 | 0.00 | 0.00 | 0.00 | 0.443132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.230635E+09 | 0.00 | 0.00 | 0.00 | 0.765402E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.172361E+09 | 0.00 | 0.00 | 0.00 | 0.559357E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 97935566.29 | 0.00 | 0.00 | 0.00 | 0.236166E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 74918299.82 | 0.00 | 0.00 | 0.00 | 6955064.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.167739E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.282087E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.209109E+10 | 0.00 | 0.00 | 0.00 | 0.216891E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 74918299.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.353002E+09 | 0.00 | 0.00 | 0.00 | 0.765402E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.297933E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.176707E+09 | 0.00 | 0.00 | 0.00 | 20742827.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144770E+09 | 0.00 | 0.00 | 0.00 | 17303191.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93061607.71 | 0.00 | 0.00 | 0.00 | 90287785.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.104607E+09 | 0.00 | 0.00 | 0.00 | 0.195825E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.172574E+09 | 0.00 | 0.00 | 0.00 | 0.547857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283107E+09 | 0.00 | 0.00 | 0.00 | 0.937265E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.244335E+09 | 0.00 | 0.00 | 0.00 | 0.795423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.149155E+09 | 0.00 | 0.00 | 0.00 | 0.426809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 79494045.98 | 0.00 | 0.00 | 0.00 | 0.100858E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.126331E+09 | 0.00 | 0.00 | 0.00 | 7125206.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.231884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.210396E+10 | 0.00 | 0.00 | 0.00 | 0.313949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 79494045.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.297933E+09 | 0.00 | 0.00 | 0.00 | 0.937265E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.342207E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.210821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.170428E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 76752183.15 | 0.00 | 0.00 | 0.00 | 6001265.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 83656697.03 | 0.00 | 0.00 | 0.00 | 0.118374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.143565E+09 | 0.00 | 0.00 | 0.00 | 0.454160E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.238303E+09 | 0.00 | 0.00 | 0.00 | 0.789008E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.176956E+09 | 0.00 | 0.00 | 0.00 | 0.574852E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 91049698.49 | 0.00 | 0.00 | 0.00 | 0.221094E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 69857396.23 | 0.00 | 0.00 | 0.00 | 3164760.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.163891E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.274399E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.204189E+10 | 0.00 | 0.00 | 0.00 | 0.216665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 69857396.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.342207E+09 | 0.00 | 0.00 | 0.00 | 0.789008E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.249949E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.152044E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122249E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51157403.05 | 0.00 | 0.00 | 0.00 | 1780351.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 57788339.12 | 0.00 | 0.00 | 0.00 | 87935272.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.102639E+09 | 0.00 | 0.00 | 0.00 | 0.329999E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.178588E+09 | 0.00 | 0.00 | 0.00 | 0.592979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.131541E+09 | 0.00 | 0.00 | 0.00 | 0.430259E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 68277216.85 | 0.00 | 0.00 | 0.00 | 0.178117E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 44904608.24 | 0.00 | 0.00 | 0.00 | 1624509.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113763E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.197521E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.147042E+10 | 0.00 | 0.00 | 0.00 | 0.162269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44904608.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.249949E+09 | 0.00 | 0.00 | 0.00 | 0.592979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.249623E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.151899E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122082E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 51064001.56 | 0.00 | 0.00 | 0.00 | 1805861.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 57915986.60 | 0.00 | 0.00 | 0.00 | 88152322.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103382E+09 | 0.00 | 0.00 | 0.00 | 0.332395E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.179307E+09 | 0.00 | 0.00 | 0.00 | 0.595323E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.132285E+09 | 0.00 | 0.00 | 0.00 | 0.432728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 68284017.12 | 0.00 | 0.00 | 0.00 | 0.178334E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 44920672.71 | 0.00 | 0.00 | 0.00 | 1690248.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113713E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.197312E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.147179E+10 | 0.00 | 0.00 | 0.00 | 0.163043E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 44920672.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.249623E+09 | 0.00 | 0.00 | 0.00 | 0.595323E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.206888E+09 | 0.00 | 0.00 | 0.00 | 215833.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.120366E+09 | 0.00 | 0.00 | 0.00 | 23384595.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98082394.82 | 0.00 | 0.00 | 0.00 | 19425230.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 61715495.26 | 0.00 | 0.00 | 0.00 | 68741798.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76187781.68 | 0.00 | 0.00 | 0.00 | 0.157554E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.131446E+09 | 0.00 | 0.00 | 0.00 | 0.423359E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.224753E+09 | 0.00 | 0.00 | 0.00 | 0.745756E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.199725E+09 | 0.00 | 0.00 | 0.00 | 0.653573E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.125840E+09 | 0.00 | 0.00 | 0.00 | 0.380189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58279947.40 | 0.00 | 0.00 | 0.00 | 0.103412E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 81447929.49 | 0.00 | 0.00 | 0.00 | 12219025.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156543E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154127E+10 | 0.00 | 0.00 | 0.00 | 0.258783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58279947.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.224753E+09 | 0.00 | 0.00 | 0.00 | 0.745756E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.206640E+09 | 0.00 | 0.00 | 0.00 | 268558.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.120411E+09 | 0.00 | 0.00 | 0.00 | 23812507.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98204990.68 | 0.00 | 0.00 | 0.00 | 20193183.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 62239535.64 | 0.00 | 0.00 | 0.00 | 70414998.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 76529880.81 | 0.00 | 0.00 | 0.00 | 0.158434E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.132265E+09 | 0.00 | 0.00 | 0.00 | 0.425977E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.225460E+09 | 0.00 | 0.00 | 0.00 | 0.748053E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.200431E+09 | 0.00 | 0.00 | 0.00 | 0.655886E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.126172E+09 | 0.00 | 0.00 | 0.00 | 0.381282E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58584898.31 | 0.00 | 0.00 | 0.00 | 0.104361E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 81562851.43 | 0.00 | 0.00 | 0.00 | 12500640.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156401E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154490E+10 | 0.00 | 0.00 | 0.00 | 0.260118E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58584898.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.225460E+09 | 0.00 | 0.00 | 0.00 | 0.748053E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 76375989.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213372E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.179277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138033E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.247917E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129624E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.326702E+09 | 0.00 | 0.00 | 1644.27 | 34814.90 | 0.732317E+09 | 413625.73 | 0.00 | 0.35 |
| May | 0.464719E+09 | 3824913.89 | 0.00 | 102718.78 | 488771.37 | 0.405150E+09 | 16476998.83 | 0.00 | 0.35 |
| June | 0.395076E+09 | 43657444.98 | 0.00 | 852995.21 | 0.00 | 333769.87 | 0.151610E+09 | 0.00 | 0.35 |
| July | 93113723.85 | 0.109174E+09 | 0.00 | 1859390.02 | 0.00 | 0.00 | 0.264174E+09 | 0.00 | 0.35 |
| August | 0.132440E+09 | 74639072.74 | 0.00 | 2204996.16 | 0.00 | 0.00 | 0.318776E+09 | 0.00 | 0.35 |
| September | 0.426347E+09 | 39807089.49 | 0.00 | 1592261.78 | 0.00 | 612604.40 | 0.233700E+09 | 0.00 | 0.35 |
| October | 0.818507E+09 | 849691.62 | 0.00 | 660011.16 | 0.00 | 89578956.75 | 0.149934E+09 | 0.00 | 0.35 |
| November | 0.660190E+09 | 0.00 | 0.00 | 5566.40 | 0.00 | 0.673461E+09 | 2533778.94 | 0.00 | 0.35 |
| December | 0.114024E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.174901E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.393469E+10 | 0.271952E+09 | 0.00 | 7279583.79 | 523586.27 | 0.846076E+10 | 0.113762E+10 | 0.00 | 0.35 |
| Minimum of Months | 76375989.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.818507E+09 | 0.109174E+09 | 0.00 | 2204996.16 | 488771.37 | 0.213372E+10 | 0.318776E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220914E+10 | 0.00 | 0.00 | 0.35 |
| February | 13506503.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153872E+10 | 0.00 | 0.00 | 0.35 |
| March | 21217445.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151983E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.103968E+09 | 0.00 | 0.00 | 0.00 | 434359.93 | 0.938625E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.356746E+09 | 3054316.36 | 470926.65 | 26471.99 | 1689946.73 | 0.504128E+09 | 5772504.95 | 740.28 | 0.35 |
| June | 0.423035E+09 | 40095590.66 | 0.00 | 581928.24 | 350361.07 | 3126526.61 | 0.109196E+09 | 0.00 | 0.35 |
| July | 0.114928E+09 | 0.105138E+09 | 0.00 | 1452736.98 | 0.00 | 0.00 | 0.241610E+09 | 0.00 | 0.35 |
| August | 0.214697E+09 | 72494161.17 | 0.00 | 1348206.55 | 0.00 | 0.00 | 0.230973E+09 | 0.00 | 0.35 |
| September | 0.462234E+09 | 38942693.38 | 0.00 | 659609.09 | 139692.40 | 49864120.41 | 0.115131E+09 | 0.00 | 0.35 |
| October | 0.694114E+09 | 348029.42 | 0.00 | 3215.61 | 527761.35 | 0.277112E+09 | 772441.64 | 0.00 | 0.35 |
| November | 0.174379E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113651E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186305E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.257883E+10 | 0.260073E+09 | 470926.65 | 4072168.46 | 3142121.48 | 0.100401E+11 | 0.703456E+09 | 740.28 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.694114E+09 | 0.105138E+09 | 470926.65 | 1452736.98 | 1689946.73 | 0.220914E+10 | 0.241610E+09 | 740.28 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.112958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178442E+10 | 0.00 | 0.00 | 0.51 |
| February | 0.120255E+10 | 0.00 | 0.00 | 4360.66 | 0.00 | 0.841714E+09 | 9931216.68 | 0.00 | 0.51 |
| March | 0.148009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.582350E+09 | 0.00 | 0.00 | 0.51 |
| April | 0.131770E+10 | 0.00 | 0.00 | 19648.34 | 0.00 | 0.156687E+09 | 9876049.91 | 0.00 | 0.51 |
| May | 0.117166E+10 | 643807.67 | 0.00 | 146351.50 | 1252188.95 | 98842880.05 | 64174881.44 | 0.00 | 0.52 |
| June | 0.809942E+09 | 27770821.71 | 0.00 | 1110724.22 | 4515972.72 | 0.00 | 0.143334E+09 | 0.00 | 0.52 |
| July | 0.660852E+09 | 51815668.23 | 0.00 | 1562734.82 | 11909817.90 | 0.00 | 70449613.63 | 0.00 | 0.52 |
| August | 0.725824E+09 | 37784871.86 | 0.00 | 1947751.88 | 7128895.96 | 0.00 | 0.125410E+09 | 0.00 | 0.52 |
| September | 0.100846E+10 | 24175646.56 | 0.00 | 1226385.69 | 2267826.29 | 0.00 | 0.148352E+09 | 0.00 | 0.52 |
| October | 0.144886E+10 | 249128.39 | 0.00 | 664717.56 | 0.00 | 7031034.34 | 0.178418E+09 | 0.00 | 0.52 |
| November | 0.158353E+10 | 0.00 | 0.00 | 85102.50 | 0.00 | 0.230986E+09 | 90394921.83 | 0.00 | 0.51 |
| December | 0.140893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102377E+10 | 0.00 | 0.00 | 0.51 |
| Annual Sum or Average | 0.139480E+11 | 0.142440E+09 | 0.00 | 6767777.17 | 27074701.82 | 0.472581E+10 | 0.840340E+09 | 0.00 | 0.52 |
| Minimum of Months | 0.660852E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 |
| Maximum of Months | 0.158353E+10 | 51815668.23 | 0.00 | 1947751.88 | 11909817.90 | 0.178442E+10 | 0.178418E+09 | 0.00 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220912E+10 | 0.00 | 0.00 | 0.35 |
| February | 5240545.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154689E+10 | 0.00 | 0.00 | 0.35 |
| March | 3855687.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153717E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.128873E+09 | 0.00 | 0.00 | 0.00 | 426288.40 | 0.912674E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.356526E+09 | 3004061.88 | 0.00 | 7422.33 | 1886059.22 | 0.506526E+09 | 1579845.26 | 0.00 | 0.35 |
| June | 0.425745E+09 | 40903463.26 | 0.00 | 693065.34 | 220905.21 | 4198532.83 | 0.107730E+09 | 0.00 | 0.35 |
| July | 0.100394E+09 | 0.106377E+09 | 0.00 | 1687243.44 | 0.00 | 0.00 | 0.255813E+09 | 0.00 | 0.35 |
| August | 0.189721E+09 | 72504782.65 | 0.00 | 1544751.48 | 0.00 | 0.00 | 0.259123E+09 | 0.00 | 0.35 |
| September | 0.469655E+09 | 38181494.95 | 0.00 | 642144.73 | 60149.10 | 43944847.86 | 0.117614E+09 | 0.00 | 0.35 |
| October | 0.698860E+09 | 138583.44 | 0.00 | 2079.88 | 685259.01 | 0.272702E+09 | 663459.04 | 0.00 | 0.35 |
| November | 0.175966E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113446E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186304E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.255484E+10 | 0.261109E+09 | 0.00 | 4576707.19 | 3278660.94 | 0.100307E+11 | 0.742524E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.698860E+09 | 0.106377E+09 | 0.00 | 1687243.44 | 1886059.22 | 0.220912E+10 | 0.259123E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 303595.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221552E+10 | 0.00 | 0.00 | 0.35 |
| February | 39389879.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151877E+10 | 0.00 | 0.00 | 0.35 |
| March | 73352950.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147389E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.261335E+09 | 0.00 | 0.00 | 0.00 | 476105.62 | 0.786144E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.567291E+09 | 2493466.69 | 87954.44 | 15727.48 | 2698266.91 | 0.303296E+09 | 4644794.59 | 399.00 | 0.35 |
| June | 0.423989E+09 | 38545509.20 | 0.00 | 603621.05 | 303368.58 | 0.00 | 0.134017E+09 | 0.00 | 0.35 |
| July | 78015995.32 | 0.102662E+09 | 0.00 | 1530394.68 | 0.00 | 0.00 | 0.285637E+09 | 0.00 | 0.35 |
| August | 0.149071E+09 | 71244002.08 | 0.00 | 1423047.78 | 0.00 | 0.00 | 0.310907E+09 | 0.00 | 0.35 |
| September | 0.502879E+09 | 37535607.27 | 0.00 | 665522.43 | 124190.15 | 40469.82 | 0.143638E+09 | 0.00 | 0.35 |
| October | 0.915695E+09 | 6213.13 | 0.00 | 1125.05 | 910812.00 | 78157558.84 | 552233.05 | 0.00 | 0.35 |
| November | 0.460294E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.858602E+09 | 0.00 | 0.00 | 0.35 |
| December | 21536337.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184808E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.349315E+10 | 0.252487E+09 | 87954.44 | 4239438.47 | 4512743.26 | 0.908250E+10 | 0.879396E+09 | 399.00 | 0.35 |
| Minimum of Months | 303595.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.915695E+09 | 0.102662E+09 | 87954.44 | 1530394.68 | 2698266.91 | 0.221552E+10 | 0.310907E+09 | 399.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 303595.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221552E+10 | 0.00 | 0.00 | 0.35 |
| February | 39884130.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151827E+10 | 0.00 | 0.00 | 0.35 |
| March | 73622372.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147362E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.263144E+09 | 0.00 | 0.00 | 0.00 | 471403.43 | 0.784344E+09 | 0.00 | 0.00 | 0.35 |
| May | 0.567441E+09 | 2487668.25 | 87910.74 | 14095.05 | 2677524.49 | 0.303579E+09 | 4094147.40 | 375.99 | 0.35 |
| June | 0.423029E+09 | 38608443.51 | 0.00 | 611729.58 | 293277.57 | 0.00 | 0.135130E+09 | 0.00 | 0.35 |
| July | 76737509.29 | 0.102707E+09 | 0.00 | 1541695.55 | 0.00 | 0.00 | 0.286838E+09 | 0.00 | 0.35 |
| August | 0.147718E+09 | 71244318.42 | 0.00 | 1439035.68 | 0.00 | 0.00 | 0.312500E+09 | 0.00 | 0.35 |
| September | 0.502716E+09 | 37521041.59 | 0.00 | 665975.70 | 102178.78 | 40523.46 | 0.144185E+09 | 0.00 | 0.35 |
| October | 0.916108E+09 | 6170.42 | 0.00 | 1042.89 | 910617.45 | 77936083.99 | 534051.77 | 0.00 | 0.35 |
| November | 0.459325E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.859555E+09 | 0.00 | 0.00 | 0.35 |
| December | 21483398.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184814E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.349151E+10 | 0.252574E+09 | 87910.74 | 4273574.45 | 4455001.71 | 0.908100E+10 | 0.883280E+09 | 375.99 | 0.35 |
| Minimum of Months | 303595.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.916108E+09 | 0.102707E+09 | 87910.74 | 1541695.55 | 2677524.49 | 0.221552E+10 | 0.312500E+09 | 375.99 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.341788E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187641E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.464429E+09 | 0.00 | 0.00 | 932.24 | 0.00 | 0.110563E+10 | 855224.19 | 0.00 | 0.35 |
| March | 0.634962E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919375E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.706571E+09 | 0.00 | 0.00 | 93.06 | 13791.67 | 0.367071E+09 | 49644.11 | 0.00 | 0.35 |
| May | 0.651152E+09 | 3657503.99 | 0.00 | 87359.79 | 486183.19 | 0.229749E+09 | 20629241.04 | 0.00 | 0.35 |
| June | 0.350988E+09 | 42663286.84 | 0.00 | 968260.93 | 0.00 | 0.00 | 0.218926E+09 | 0.00 | 0.35 |
| July | 52760767.75 | 0.107196E+09 | 0.00 | 1965033.63 | 0.00 | 0.00 | 0.309949E+09 | 0.00 | 0.35 |
| August | 70351586.39 | 73556081.85 | 0.00 | 2441366.92 | 0.00 | 0.00 | 0.391809E+09 | 0.00 | 0.35 |
| September | 0.370903E+09 | 38728807.16 | 0.00 | 1826811.78 | 0.00 | 0.00 | 0.316004E+09 | 0.00 | 0.35 |
| October | 0.798934E+09 | 870214.92 | 0.00 | 1039908.65 | 0.00 | 6092062.24 | 0.295667E+09 | 0.00 | 0.35 |
| November | 0.100486E+10 | 0.00 | 0.00 | 40403.75 | 0.00 | 0.341576E+09 | 24380640.62 | 0.00 | 0.35 |
| December | 0.534695E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133598E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.598239E+10 | 0.266672E+09 | 0.00 | 8370170.74 | 499974.86 | 0.618188E+10 | 0.157827E+10 | 0.00 | 0.35 |
| Minimum of Months | 52760767.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.100486E+10 | 0.107196E+09 | 0.00 | 2441366.92 | 486183.19 | 0.187641E+10 | 0.391809E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.240856E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197680E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.374166E+09 | 0.00 | 0.00 | 143.12 | 0.00 | 0.119492E+10 | 303326.22 | 0.00 | 0.35 |
| March | 0.533806E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101950E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.658865E+09 | 0.00 | 0.00 | 102.12 | 11260.13 | 0.414088E+09 | 49803.91 | 0.00 | 0.35 |
| May | 0.624264E+09 | 3654700.40 | 0.00 | 103561.77 | 497980.42 | 0.254665E+09 | 24612107.47 | 0.00 | 0.35 |
| June | 0.322401E+09 | 43079762.21 | 0.00 | 1158574.07 | 0.00 | 0.00 | 0.250011E+09 | 0.00 | 0.35 |
| July | 36346603.34 | 0.108209E+09 | 0.00 | 2232795.64 | 0.00 | 0.00 | 0.323710E+09 | 0.00 | 0.35 |
| August | 52694040.37 | 73552452.16 | 0.00 | 2773940.60 | 0.00 | 0.00 | 0.409434E+09 | 0.00 | 0.35 |
| September | 0.354738E+09 | 39110141.41 | 0.00 | 2089654.59 | 0.00 | 0.00 | 0.333828E+09 | 0.00 | 0.35 |
| October | 0.767489E+09 | 870935.22 | 0.00 | 1137719.90 | 0.00 | 13473596.10 | 0.322567E+09 | 0.00 | 0.35 |
| November | 0.973274E+09 | 0.00 | 0.00 | 56282.90 | 0.00 | 0.365663E+09 | 33322535.09 | 0.00 | 0.35 |
| December | 0.439519E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143079E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.537842E+10 | 0.268477E+09 | 0.00 | 9552774.72 | 509240.55 | 0.666990E+10 | 0.169784E+10 | 0.00 | 0.35 |
| Minimum of Months | 36346603.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.973274E+09 | 0.108209E+09 | 0.00 | 2773940.60 | 497980.42 | 0.197680E+10 | 0.409434E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.603981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381374E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.866757E+09 | 0.00 | 0.00 | 345292.70 | 0.00 | 0.221606E+10 | 60261480.54 | 0.00 | 0.35 |
| March | 0.155871E+10 | 0.00 | 0.00 | 178890.04 | 0.00 | 0.152093E+10 | 53787827.07 | 0.00 | 0.35 |
| April | 0.165867E+10 | 2609.21 | 0.00 | 1162960.54 | 0.00 | 0.358436E+09 | 0.242533E+09 | 0.00 | 0.35 |
| May | 0.119057E+10 | 7890339.40 | 0.00 | 2488146.84 | 192566.36 | 0.302697E+09 | 0.410613E+09 | 0.00 | 0.35 |
| June | 0.416675E+09 | 94741536.57 | 0.00 | 5180561.50 | 0.00 | 0.00 | 0.710262E+09 | 0.00 | 0.35 |
| July | 76858723.31 | 0.224938E+09 | 0.00 | 5501063.15 | 0.00 | 0.00 | 0.619944E+09 | 0.00 | 0.35 |
| August | 0.147504E+09 | 0.151232E+09 | 0.00 | 6225136.05 | 0.00 | 0.00 | 0.746004E+09 | 0.00 | 0.35 |
| September | 0.781958E+09 | 82164375.87 | 0.00 | 4244579.19 | 0.00 | 3019725.01 | 0.536983E+09 | 0.00 | 0.35 |
| October | 0.156184E+10 | 1676502.84 | 0.00 | 2313518.73 | 0.00 | 0.158396E+09 | 0.406931E+09 | 0.00 | 0.35 |
| November | 0.148365E+10 | 0.00 | 0.00 | 140980.72 | 0.00 | 0.114908E+10 | 66023025.21 | 0.00 | 0.35 |
| December | 0.673935E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304580E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.110211E+11 | 0.562645E+09 | 0.00 | 27781129.47 | 192566.36 | 0.125682E+11 | 0.385334E+10 | 0.00 | 0.35 |
| Minimum of Months | 76858723.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.165867E+10 | 0.224938E+09 | 0.00 | 6225136.05 | 192566.36 | 0.381374E+10 | 0.746004E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 32527444.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.437420E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.200550E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289792E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.640630E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243726E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.153117E+10 | 0.00 | 0.00 | 73195.00 | 0.00 | 0.609755E+09 | 22255605.28 | 0.00 | 0.35 |
| May | 0.124820E+10 | 8076827.21 | 0.00 | 1477089.25 | 541846.69 | 0.364018E+09 | 0.255152E+09 | 0.00 | 0.35 |
| June | 0.455186E+09 | 89645661.70 | 0.00 | 4527274.80 | 0.00 | 0.00 | 0.673906E+09 | 0.00 | 0.35 |
| July | 87808015.83 | 0.217962E+09 | 0.00 | 4822860.67 | 0.00 | 0.00 | 0.609611E+09 | 0.00 | 0.35 |
| August | 0.218285E+09 | 0.147505E+09 | 0.00 | 4628307.91 | 0.00 | 0.00 | 0.673755E+09 | 0.00 | 0.35 |
| September | 0.884754E+09 | 80409301.82 | 0.00 | 1915557.93 | 104723.69 | 72769152.78 | 0.310613E+09 | 0.00 | 0.35 |
| October | 0.148818E+10 | 1267752.02 | 0.00 | 70573.76 | 201988.37 | 0.465241E+09 | 22138734.07 | 0.00 | 0.35 |
| November | 0.533838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208170E+10 | 0.00 | 0.00 | 0.35 |
| December | 16096643.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.369872E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.733723E+10 | 0.544867E+09 | 0.00 | 17514859.32 | 848558.74 | 0.170016E+11 | 0.256743E+10 | 0.00 | 0.35 |
| Minimum of Months | 16096643.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.153117E+10 | 0.217962E+09 | 0.00 | 4822860.67 | 541846.69 | 0.437420E+10 | 0.673906E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.599369E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381886E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.903544E+09 | 0.00 | 0.00 | 320165.55 | 0.00 | 0.217304E+10 | 68092116.95 | 0.00 | 0.35 |
| March | 0.162260E+10 | 0.00 | 0.00 | 80690.84 | 0.00 | 0.147043E+10 | 45060293.62 | 0.00 | 0.35 |
| April | 0.159622E+10 | 2635.52 | 0.00 | 1242005.50 | 0.00 | 0.374109E+09 | 0.299255E+09 | 0.00 | 0.35 |
| May | 0.118657E+10 | 7900280.00 | 0.00 | 2418901.17 | 59061.51 | 0.296169E+09 | 0.422958E+09 | 0.00 | 0.35 |
| June | 0.390117E+09 | 95677274.14 | 0.00 | 5757750.13 | 0.00 | 0.00 | 0.737382E+09 | 0.00 | 0.35 |
| July | 88121456.03 | 0.227040E+09 | 0.00 | 6134077.41 | 0.00 | 0.00 | 0.606410E+09 | 0.00 | 0.35 |
| August | 0.135415E+09 | 0.151139E+09 | 0.00 | 6890046.39 | 0.00 | 0.00 | 0.759220E+09 | 0.00 | 0.35 |
| September | 0.755251E+09 | 80922944.62 | 0.00 | 4327172.90 | 0.00 | 7783118.02 | 0.565744E+09 | 0.00 | 0.35 |
| October | 0.154834E+10 | 1674541.92 | 0.00 | 2239485.25 | 0.00 | 0.152604E+09 | 0.430403E+09 | 0.00 | 0.35 |
| November | 0.149004E+10 | 0.00 | 0.00 | 109950.37 | 0.00 | 0.115457E+10 | 53657492.01 | 0.00 | 0.35 |
| December | 0.686329E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.303301E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.110019E+11 | 0.564357E+09 | 0.00 | 29520245.51 | 59061.51 | 0.124806E+11 | 0.398818E+10 | 0.00 | 0.35 |
| Minimum of Months | 88121456.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.162260E+10 | 0.227040E+09 | 0.00 | 6890046.39 | 59061.51 | 0.381886E+10 | 0.759220E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 30292490.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.437639E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.203305E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289401E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.696943E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237906E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.155178E+10 | 0.00 | 0.00 | 45445.63 | 0.00 | 0.592825E+09 | 29525672.84 | 0.00 | 0.35 |
| May | 0.122467E+10 | 8088023.92 | 0.00 | 1341514.54 | 319345.07 | 0.381626E+09 | 0.264000E+09 | 0.00 | 0.35 |
| June | 0.409837E+09 | 90906660.18 | 0.00 | 5122589.58 | 0.00 | 0.00 | 0.720754E+09 | 0.00 | 0.35 |
| July | 96526847.68 | 0.220567E+09 | 0.00 | 5454479.89 | 0.00 | 0.00 | 0.598677E+09 | 0.00 | 0.35 |
| August | 0.197742E+09 | 0.147536E+09 | 0.00 | 5257037.30 | 0.00 | 0.00 | 0.696692E+09 | 0.00 | 0.35 |
| September | 0.893668E+09 | 78614723.33 | 0.00 | 1933029.97 | 81394.69 | 59779312.68 | 0.324244E+09 | 0.00 | 0.35 |
| October | 0.152526E+10 | 1352464.96 | 0.00 | 42286.50 | 79118.94 | 0.438695E+09 | 11800416.69 | 0.00 | 0.35 |
| November | 0.516458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209693E+10 | 0.00 | 0.00 | 0.35 |
| December | 9450381.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370536E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.735592E+10 | 0.547065E+09 | 0.00 | 19196383.41 | 479858.70 | 0.169247E+11 | 0.264569E+10 | 0.00 | 0.35 |
| Minimum of Months | 9450381.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.155178E+10 | 0.220567E+09 | 0.00 | 5454479.89 | 319345.07 | 0.437639E+10 | 0.720754E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.406868E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401549E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.695693E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241675E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.178102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131136E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.205560E+10 | 0.00 | 0.00 | 6599.69 | 3011.51 | 0.125902E+09 | 8702088.02 | 0.00 | 0.35 |
| May | 0.146672E+10 | 7613616.96 | 0.00 | 1262866.96 | 635743.84 | 0.127060E+09 | 0.297042E+09 | 0.00 | 0.35 |
| June | 0.311847E+09 | 85658644.41 | 0.00 | 4359712.30 | 0.00 | 0.00 | 0.845277E+09 | 0.00 | 0.36 |
| July | 41982378.32 | 0.211523E+09 | 0.00 | 4522228.06 | 0.00 | 0.00 | 0.667534E+09 | 0.00 | 0.35 |
| August | 0.125238E+09 | 0.144525E+09 | 0.00 | 4584935.78 | 0.00 | 0.00 | 0.790056E+09 | 0.00 | 0.35 |
| September | 0.892159E+09 | 76794572.42 | 0.00 | 1933183.94 | 77458.37 | 0.00 | 0.419914E+09 | 0.00 | 0.35 |
| October | 0.190144E+10 | 1380815.24 | 0.00 | 74399.37 | 87459.76 | 0.102914E+09 | 39540496.45 | 0.00 | 0.35 |
| November | 0.132410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131682E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.456716E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327344E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.114594E+11 | 0.527495E+09 | 0.00 | 16743926.08 | 803673.48 | 0.126897E+11 | 0.306807E+10 | 0.00 | 0.35 |
| Minimum of Months | 41982378.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.205560E+10 | 0.211523E+09 | 0.00 | 4584935.78 | 635743.84 | 0.401549E+10 | 0.845277E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.405347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401701E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.695899E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241656E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.177918E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131326E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.205483E+10 | 0.00 | 0.00 | 8273.06 | 1845.69 | 0.126593E+09 | 10519488.34 | 0.00 | 0.35 |
| May | 0.146661E+10 | 7611761.04 | 0.00 | 1260784.78 | 625282.99 | 0.127763E+09 | 0.296866E+09 | 0.00 | 0.35 |
| June | 0.311601E+09 | 85732780.45 | 0.00 | 4379642.86 | 0.00 | 0.00 | 0.845475E+09 | 0.00 | 0.36 |
| July | 42641342.92 | 0.211597E+09 | 0.00 | 4530978.62 | 0.00 | 0.00 | 0.666757E+09 | 0.00 | 0.35 |
| August | 0.122080E+09 | 0.144522E+09 | 0.00 | 4609094.71 | 0.00 | 0.00 | 0.793350E+09 | 0.00 | 0.35 |
| September | 0.890587E+09 | 76746430.36 | 0.00 | 1939779.48 | 75237.74 | 0.00 | 0.422446E+09 | 0.00 | 0.35 |
| October | 0.190434E+10 | 1380532.48 | 0.00 | 74294.94 | 87394.22 | 0.101758E+09 | 38152385.92 | 0.00 | 0.35 |
| November | 0.132238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131839E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.456514E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327364E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.114520E+11 | 0.527590E+09 | 0.00 | 16802848.46 | 789760.63 | 0.126950E+11 | 0.307357E+10 | 0.00 | 0.35 |
| Minimum of Months | 42641342.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.205483E+10 | 0.211597E+09 | 0.00 | 4609094.71 | 625282.99 | 0.401701E+10 | 0.845475E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.157201E+10 | 0.00 | 0.00 | 5394.91 | 0.00 | 0.287250E+10 | 6404009.58 | 0.00 | 0.35 |
| February | 0.183366E+10 | 0.00 | 0.00 | 499752.51 | 0.00 | 0.124125E+10 | 0.108649E+09 | 0.00 | 0.35 |
| March | 0.261397E+10 | 0.00 | 0.00 | 230848.92 | 0.00 | 0.494919E+09 | 80606245.80 | 0.00 | 0.35 |
| April | 0.190804E+10 | 2764.64 | 0.00 | 1283735.26 | 0.00 | 58020204.75 | 0.364438E+09 | 0.00 | 0.35 |
| May | 0.135433E+10 | 7495602.95 | 0.00 | 2407717.00 | 256051.69 | 86730867.06 | 0.495552E+09 | 0.00 | 0.35 |
| June | 0.288088E+09 | 91709074.45 | 0.00 | 5045674.03 | 0.00 | 0.00 | 0.864601E+09 | 0.00 | 0.36 |
| July | 34178535.81 | 0.219636E+09 | 0.00 | 5233414.74 | 0.00 | 0.00 | 0.673622E+09 | 0.00 | 0.35 |
| August | 86866453.97 | 0.148650E+09 | 0.00 | 6285325.55 | 0.00 | 0.00 | 0.826580E+09 | 0.00 | 0.35 |
| September | 0.650084E+09 | 79331703.30 | 0.00 | 4612585.55 | 0.00 | 0.00 | 0.723923E+09 | 0.00 | 0.35 |
| October | 0.146593E+10 | 1729538.07 | 0.00 | 3273074.99 | 0.00 | 0.00 | 0.752792E+09 | 0.00 | 0.35 |
| November | 0.203117E+10 | 0.00 | 0.00 | 547408.43 | 0.00 | 0.531882E+09 | 0.225402E+09 | 0.00 | 0.35 |
| December | 0.190814E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184171E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.157465E+11 | 0.548554E+09 | 0.00 | 29424931.87 | 256051.69 | 0.712701E+10 | 0.512257E+10 | 0.00 | 0.35 |
| Minimum of Months | 34178535.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.261397E+10 | 0.219636E+09 | 0.00 | 6285325.55 | 256051.69 | 0.287250E+10 | 0.864601E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.157326E+10 | 0.00 | 0.00 | 6107.78 | 0.00 | 0.287094E+10 | 6933786.46 | 0.00 | 0.35 |
| February | 0.183438E+10 | 0.00 | 0.00 | 503476.08 | 0.00 | 0.123998E+10 | 0.109360E+09 | 0.00 | 0.35 |
| March | 0.261496E+10 | 0.00 | 0.00 | 238401.53 | 0.00 | 0.492048E+09 | 83380786.88 | 0.00 | 0.35 |
| April | 0.190356E+10 | 2766.98 | 0.00 | 1308290.35 | 0.00 | 58020105.28 | 0.369753E+09 | 0.00 | 0.35 |
| May | 0.135205E+10 | 7494539.19 | 0.00 | 2409991.75 | 247492.69 | 85958290.05 | 0.498527E+09 | 0.00 | 0.35 |
| June | 0.287805E+09 | 91760426.33 | 0.00 | 5062943.92 | 0.00 | 0.00 | 0.864793E+09 | 0.00 | 0.36 |
| July | 35881934.58 | 0.219687E+09 | 0.00 | 5242777.04 | 0.00 | 0.00 | 0.671821E+09 | 0.00 | 0.35 |
| August | 85950472.78 | 0.148642E+09 | 0.00 | 6302638.00 | 0.00 | 0.00 | 0.827543E+09 | 0.00 | 0.35 |
| September | 0.647785E+09 | 79297649.10 | 0.00 | 4626477.56 | 0.00 | 0.00 | 0.726606E+09 | 0.00 | 0.35 |
| October | 0.146594E+10 | 1729679.81 | 0.00 | 3288750.28 | 0.00 | 0.00 | 0.752860E+09 | 0.00 | 0.35 |
| November | 0.202654E+10 | 0.00 | 0.00 | 551630.95 | 0.00 | 0.534928E+09 | 0.226942E+09 | 0.00 | 0.35 |
| December | 0.191127E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183859E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.157394E+11 | 0.548614E+09 | 0.00 | 29541485.24 | 247492.69 | 0.712047E+10 | 0.513852E+10 | 0.00 | 0.35 |
| Minimum of Months | 35881934.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.261496E+10 | 0.219687E+09 | 0.00 | 6302638.00 | 247492.69 | 0.287094E+10 | 0.864793E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.124474E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207843E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.175060E+09 | 0.00 | 0.00 | 287640.10 | 0.00 | 0.134837E+10 | 38754899.55 | 0.00 | 0.35 |
| March | 0.286061E+09 | 0.00 | 0.00 | 381413.02 | 0.00 | 0.120677E+10 | 66224173.55 | 0.00 | 0.35 |
| April | 0.339849E+09 | 1103.58 | 0.00 | 932209.71 | 0.00 | 0.635122E+09 | 0.118387E+09 | 0.00 | 0.35 |
| May | 0.365259E+09 | 4086107.95 | 0.00 | 1342535.33 | 18577.36 | 0.398142E+09 | 0.151780E+09 | 0.00 | 0.35 |
| June | 0.289319E+09 | 48562754.42 | 0.00 | 1837323.52 | 0.00 | 63436850.50 | 0.166897E+09 | 0.00 | 0.35 |
| July | 0.178156E+09 | 0.113187E+09 | 0.00 | 1796622.71 | 0.00 | 386205.99 | 0.153834E+09 | 0.00 | 0.35 |
| August | 0.207459E+09 | 76257081.61 | 0.00 | 2110366.46 | 0.00 | 29998408.23 | 0.178198E+09 | 0.00 | 0.35 |
| September | 0.273528E+09 | 41937119.69 | 0.00 | 1579711.13 | 0.00 | 0.195169E+09 | 0.153627E+09 | 0.00 | 0.35 |
| October | 0.380245E+09 | 821109.26 | 0.00 | 1020955.44 | 0.00 | 0.496583E+09 | 0.116138E+09 | 0.00 | 0.35 |
| November | 0.285761E+09 | 0.00 | 0.00 | 139637.50 | 0.00 | 0.994631E+09 | 44136820.63 | 0.00 | 0.35 |
| December | 0.113692E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.174059E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.301887E+10 | 0.284853E+09 | 0.00 | 11428414.90 | 18577.36 | 0.918764E+10 | 0.118798E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.113692E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 386205.99 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.380245E+09 | 0.113187E+09 | 0.00 | 2110366.46 | 18577.36 | 0.207843E+10 | 0.178198E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 1252623.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219735E+10 | 0.00 | 0.00 | 0.35 |
| February | 43055245.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150195E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.125302E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140998E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.302974E+09 | 0.00 | 0.00 | 180067.85 | 0.00 | 0.733505E+09 | 30206037.24 | 0.00 | 0.35 |
| May | 0.379781E+09 | 4218023.69 | 0.00 | 780610.72 | 159897.53 | 0.428643E+09 | 94520479.19 | 0.00 | 0.35 |
| June | 0.304540E+09 | 46314483.76 | 0.00 | 1545850.38 | 0.00 | 57340327.84 | 0.157059E+09 | 0.00 | 0.35 |
| July | 0.185102E+09 | 0.110289E+09 | 0.00 | 1502861.21 | 0.00 | 253698.57 | 0.146319E+09 | 0.00 | 0.35 |
| August | 0.226195E+09 | 74679182.72 | 0.00 | 1509971.16 | 0.00 | 30861443.56 | 0.154001E+09 | 0.00 | 0.35 |
| September | 0.268421E+09 | 40988611.38 | 0.00 | 600073.77 | 21028.98 | 0.251573E+09 | 82429077.06 | 0.00 | 0.35 |
| October | 0.264449E+09 | 628761.35 | 0.00 | 60918.63 | 136682.80 | 0.675819E+09 | 10085895.30 | 0.00 | 0.35 |
| November | 59631189.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124102E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185268E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.216070E+10 | 0.277118E+09 | 0.00 | 6180353.72 | 317609.31 | 0.103810E+11 | 0.674620E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 253698.57 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.379781E+09 | 0.110289E+09 | 0.00 | 1545850.38 | 159897.53 | 0.219735E+10 | 0.157059E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.131138E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207188E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.188098E+09 | 0.00 | 0.00 | 217150.50 | 0.00 | 0.133896E+10 | 35650522.32 | 0.00 | 0.35 |
| March | 0.301776E+09 | 0.00 | 0.00 | 266317.78 | 0.00 | 0.118852E+10 | 70883801.00 | 0.00 | 0.35 |
| April | 0.340339E+09 | 1122.15 | 0.00 | 858187.87 | 0.00 | 0.627566E+09 | 0.130431E+09 | 0.00 | 0.35 |
| May | 0.371554E+09 | 4094487.16 | 0.00 | 1191133.82 | 0.00 | 0.392444E+09 | 0.154684E+09 | 0.00 | 0.35 |
| June | 0.277273E+09 | 49011326.09 | 0.00 | 2039305.72 | 0.00 | 59316555.22 | 0.188237E+09 | 0.00 | 0.35 |
| July | 0.166546E+09 | 0.114490E+09 | 0.00 | 2069580.92 | 0.00 | 2050624.92 | 0.166180E+09 | 0.00 | 0.35 |
| August | 0.198890E+09 | 76208364.30 | 0.00 | 2314227.82 | 0.00 | 28255731.88 | 0.192084E+09 | 0.00 | 0.35 |
| September | 0.280000E+09 | 41301966.55 | 0.00 | 1529419.29 | 0.00 | 0.188527E+09 | 0.158188E+09 | 0.00 | 0.35 |
| October | 0.394317E+09 | 820670.56 | 0.00 | 873997.70 | 0.00 | 0.486225E+09 | 0.115736E+09 | 0.00 | 0.35 |
| November | 0.287629E+09 | 0.00 | 0.00 | 107099.87 | 0.00 | 0.996364E+09 | 39261077.08 | 0.00 | 0.35 |
| December | 0.113390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.174066E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.305095E+10 | 0.285928E+09 | 0.00 | 11466421.29 | 0.00 | 0.912077E+10 | 0.125134E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.113390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2050624.92 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.394317E+09 | 0.114490E+09 | 0.00 | 2314227.82 | 0.00 | 0.207188E+10 | 0.192084E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219858E+10 | 0.00 | 0.00 | 0.35 |
| February | 34790042.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150907E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.118743E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141453E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.338001E+09 | 0.00 | 0.00 | 74562.25 | 0.00 | 0.710539E+09 | 22867111.44 | 0.00 | 0.35 |
| May | 0.397959E+09 | 4228109.52 | 0.00 | 624803.13 | 22746.62 | 0.419592E+09 | 88678784.45 | 0.00 | 0.35 |
| June | 0.289759E+09 | 46915791.70 | 0.00 | 1756392.05 | 0.00 | 56835111.07 | 0.178578E+09 | 0.00 | 0.35 |
| July | 0.171364E+09 | 0.111859E+09 | 0.00 | 1812376.52 | 0.00 | 2046100.02 | 0.160253E+09 | 0.00 | 0.35 |
| August | 0.216458E+09 | 74691854.88 | 0.00 | 1681307.29 | 0.00 | 28635209.11 | 0.170794E+09 | 0.00 | 0.35 |
| September | 0.293398E+09 | 40016354.57 | 0.00 | 520733.88 | 0.00 | 0.238706E+09 | 74222403.08 | 0.00 | 0.35 |
| October | 0.272210E+09 | 670796.63 | 0.00 | 10854.46 | 1160.60 | 0.672759E+09 | 2188558.68 | 0.00 | 0.35 |
| November | 43101320.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125680E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185268E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.217578E+10 | 0.278382E+09 | 0.00 | 6481029.57 | 23907.21 | 0.103608E+11 | 0.697582E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2046100.02 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.397959E+09 | 0.111859E+09 | 0.00 | 1812376.52 | 22746.62 | 0.219858E+10 | 0.178578E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 3840328.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220328E+10 | 0.00 | 0.00 | 0.35 |
| February | 61522801.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148983E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.203372E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133803E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.438883E+09 | 0.00 | 0.00 | 23934.59 | 0.00 | 0.624810E+09 | 10214285.73 | 0.00 | 0.35 |
| May | 0.481548E+09 | 3963342.98 | 0.00 | 480842.20 | 195655.21 | 0.353360E+09 | 81328959.75 | 0.00 | 0.35 |
| June | 0.334072E+09 | 44450761.87 | 0.00 | 1297483.20 | 0.00 | 14608283.94 | 0.190300E+09 | 0.00 | 0.35 |
| July | 0.159914E+09 | 0.107393E+09 | 0.00 | 1407868.92 | 0.00 | 0.00 | 0.184897E+09 | 0.00 | 0.35 |
| August | 0.223009E+09 | 73000786.84 | 0.00 | 1352129.72 | 0.00 | 11527364.77 | 0.194930E+09 | 0.00 | 0.35 |
| September | 0.331553E+09 | 39203125.81 | 0.00 | 510442.34 | 27315.84 | 0.187372E+09 | 97858469.33 | 0.00 | 0.35 |
| October | 0.426949E+09 | 620652.73 | 0.00 | 8005.30 | 159652.86 | 0.530827E+09 | 3071398.25 | 0.00 | 0.35 |
| November | 0.124690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118454E+10 | 0.00 | 0.00 | 0.35 |
| December | 307378.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186072E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.278966E+10 | 0.268632E+09 | 0.00 | 5080706.27 | 382623.91 | 0.979890E+10 | 0.762600E+09 | 0.00 | 0.35 |
| Minimum of Months | 307378.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.481548E+09 | 0.107393E+09 | 0.00 | 1407868.92 | 195655.21 | 0.220328E+10 | 0.194930E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 3840291.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220328E+10 | 0.00 | 0.00 | 0.35 |
| February | 60258060.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149108E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.201966E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133941E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.439895E+09 | 0.00 | 0.00 | 24528.24 | 0.00 | 0.624458E+09 | 10226313.28 | 0.00 | 0.35 |
| May | 0.481032E+09 | 3962727.55 | 0.00 | 482030.97 | 181555.09 | 0.354369E+09 | 81197122.30 | 0.00 | 0.35 |
| June | 0.333995E+09 | 44501543.79 | 0.00 | 1313768.33 | 0.00 | 14608113.39 | 0.190837E+09 | 0.00 | 0.35 |
| July | 0.158731E+09 | 0.107460E+09 | 0.00 | 1419214.24 | 0.00 | 0.00 | 0.186097E+09 | 0.00 | 0.35 |
| August | 0.222987E+09 | 72996911.92 | 0.00 | 1363205.63 | 0.00 | 11494316.71 | 0.195227E+09 | 0.00 | 0.35 |
| September | 0.332180E+09 | 39169085.84 | 0.00 | 509848.95 | 23901.65 | 0.187073E+09 | 97938001.95 | 0.00 | 0.35 |
| October | 0.425915E+09 | 641317.61 | 0.00 | 8029.16 | 121777.65 | 0.531593E+09 | 3132045.74 | 0.00 | 0.35 |
| November | 0.123232E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118595E+10 | 0.00 | 0.00 | 0.35 |
| December | 307379.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186072E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.278434E+10 | 0.268732E+09 | 0.00 | 5120625.54 | 327234.40 | 0.980403E+10 | 0.764655E+09 | 0.00 | 0.35 |
| Minimum of Months | 307379.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.481032E+09 | 0.107460E+09 | 0.00 | 1419214.24 | 181555.09 | 0.220328E+10 | 0.195227E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.256139E+09 | 0.00 | 0.00 | 11861.86 | 0.00 | 0.195062E+10 | 8237434.83 | 0.00 | 0.35 |
| February | 0.349438E+09 | 0.00 | 0.00 | 291518.62 | 0.00 | 0.117518E+10 | 51598003.10 | 0.00 | 0.35 |
| March | 0.445845E+09 | 0.00 | 0.00 | 337961.15 | 0.00 | 0.104859E+10 | 80098004.18 | 0.00 | 0.35 |
| April | 0.472839E+09 | 1187.85 | 0.00 | 732217.57 | 0.00 | 0.505529E+09 | 0.133653E+09 | 0.00 | 0.35 |
| May | 0.471371E+09 | 3854744.25 | 0.00 | 1006251.65 | 20812.46 | 0.302372E+09 | 0.160446E+09 | 0.00 | 0.35 |
| June | 0.319961E+09 | 47174348.58 | 0.00 | 1592304.07 | 0.00 | 15881222.21 | 0.203235E+09 | 0.00 | 0.35 |
| July | 0.155060E+09 | 0.110829E+09 | 0.00 | 1688222.11 | 0.00 | 0.00 | 0.190284E+09 | 0.00 | 0.35 |
| August | 0.194196E+09 | 74770060.16 | 0.00 | 2019550.21 | 0.00 | 11731317.47 | 0.227639E+09 | 0.00 | 0.35 |
| September | 0.334045E+09 | 40542668.00 | 0.00 | 1529752.31 | 0.00 | 0.110013E+09 | 0.199043E+09 | 0.00 | 0.35 |
| October | 0.584858E+09 | 851816.27 | 0.00 | 978101.37 | 0.00 | 0.287152E+09 | 0.149628E+09 | 0.00 | 0.35 |
| November | 0.444094E+09 | 0.00 | 0.00 | 179653.13 | 0.00 | 0.835753E+09 | 64550682.76 | 0.00 | 0.35 |
| December | 0.269438E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159683E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.429728E+10 | 0.278023E+09 | 0.00 | 10367394.04 | 20812.46 | 0.783966E+10 | 0.146841E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.155060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.584858E+09 | 0.110829E+09 | 0.00 | 2019550.21 | 20812.46 | 0.195062E+10 | 0.227639E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.256473E+09 | 0.00 | 0.00 | 12581.09 | 0.00 | 0.194977E+10 | 8793554.38 | 0.00 | 0.35 |
| February | 0.350049E+09 | 0.00 | 0.00 | 293795.06 | 0.00 | 0.117451E+10 | 51698285.03 | 0.00 | 0.35 |
| March | 0.446005E+09 | 0.00 | 0.00 | 340878.77 | 0.00 | 0.104712E+10 | 81608926.62 | 0.00 | 0.35 |
| April | 0.471438E+09 | 1189.93 | 0.00 | 743693.87 | 0.00 | 0.506414E+09 | 0.134464E+09 | 0.00 | 0.35 |
| May | 0.469666E+09 | 3854426.26 | 0.00 | 1013595.17 | 15376.16 | 0.303424E+09 | 0.161217E+09 | 0.00 | 0.35 |
| June | 0.318933E+09 | 47210101.35 | 0.00 | 1606907.22 | 0.00 | 16195315.51 | 0.204165E+09 | 0.00 | 0.35 |
| July | 0.155173E+09 | 0.110879E+09 | 0.00 | 1696697.37 | 0.00 | 0.00 | 0.190189E+09 | 0.00 | 0.35 |
| August | 0.194202E+09 | 74762680.71 | 0.00 | 2030569.56 | 0.00 | 11731312.64 | 0.227731E+09 | 0.00 | 0.35 |
| September | 0.331996E+09 | 40520610.43 | 0.00 | 1537361.27 | 0.00 | 0.110297E+09 | 0.201023E+09 | 0.00 | 0.35 |
| October | 0.583622E+09 | 852061.61 | 0.00 | 982553.80 | 0.00 | 0.287457E+09 | 0.150738E+09 | 0.00 | 0.35 |
| November | 0.442574E+09 | 0.00 | 0.00 | 181311.47 | 0.00 | 0.836903E+09 | 64819151.30 | 0.00 | 0.35 |
| December | 0.268816E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159749E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.428895E+10 | 0.278080E+09 | 0.00 | 10439944.66 | 15376.16 | 0.784131E+10 | 0.147645E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.155173E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.583622E+09 | 0.110879E+09 | 0.00 | 2030569.56 | 15376.16 | 0.194977E+10 | 0.227731E+09 | 0.00 | 0.35 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:37
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.915777E+11 | 0.299672E+11 | 0.00 | 0.291357E+10 | 0.331569E+11 |
| February | 0.117210E+12 | 0.223048E+11 | 0.00 | 0.205420E+10 | 0.200650E+11 |
| March | 0.180479E+12 | 0.206909E+11 | 0.00 | 0.206244E+10 | 0.153137E+11 |
| April | 0.181364E+12 | 0.152806E+11 | 0.00 | 0.148428E+10 | 0.949206E+10 |
| May | 0.234755E+12 | 0.155116E+11 | 0.00 | 0.133293E+10 | 0.198855E+11 |
| June | 0.252327E+12 | 0.104911E+11 | 0.00 | 0.922100E+09 | 0.583675E+11 |
| July | 0.248959E+12 | 0.615961E+10 | 0.00 | 0.669139E+09 | 0.103976E+12 |
| August | 0.214833E+12 | 0.847908E+10 | 0.00 | 0.808268E+09 | 0.859752E+11 |
| September | 0.169328E+12 | 0.130375E+11 | 0.00 | 0.113160E+10 | 0.464854E+11 |
| October | 0.118699E+12 | 0.154423E+11 | 0.00 | 0.163473E+10 | 0.120629E+11 |
| November | 0.728516E+11 | 0.195185E+11 | 0.00 | 0.190500E+10 | 0.124892E+11 |
| December | 0.628431E+11 | 0.245400E+11 | 0.00 | 0.243271E+10 | 0.247035E+11 |
| Annual Sum or Average | 0.194522E+13 | 0.201423E+12 | 0.00 | 0.193510E+11 | 0.441973E+12 |
| Minimum of Months | 0.628431E+11 | 0.615961E+10 | 0.00 | 0.669139E+09 | 0.949206E+10 |
| Maximum of Months | 0.252327E+12 | 0.299672E+11 | 0.00 | 0.291357E+10 | 0.103976E+12 |