Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2023-10-16 09:14:42
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 2207.40 | 704.20 | 781.66 |
| Net Site Energy | 2207.40 | 704.20 | 781.66 |
| Total Source Energy | 5113.97 | 1631.45 | 1810.91 |
| Net Source Energy | 5113.97 | 1631.45 | 1810.91 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 901.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 69.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 49.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 103.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 525.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1306.36 | 901.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 901.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 69.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 49.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 103.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 525.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 901.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 69.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 49.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 103.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 525.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 247.37 | 319.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 462.60 | 319.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 222.86 | 287.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 416.75 | 287.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1306.360 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1306.360 | 100.00 |
| Total On-Site and Utility Electric Sources | 1306.360 | 100.00 |
| Total Electricity End Uses | 1306.360 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 48.17 |
| Air to Air Heat Recovery for Heating | 0.00 | 51.83 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8755.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
| Latitude [deg] | 48.57 |
| Longitude [deg] | -93.4 |
| Elevation [m] | 359.00 |
| Time Zone | -6.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 29-JUN-16:30 | 04-JAN-08:09 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 146802.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 28267.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 4289.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22709.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 9172.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 25970.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 90409.55 | 146802.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 146802.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 28267.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4034.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 254.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 9172.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 25970.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 976.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 220.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 329.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1662.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 4137.24 | 976.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 345.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 78.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 55.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 116.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1465.04 | 345.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 311.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 70.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 105.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 530.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1319.86 | 311.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.372722 |
| SPLIT GNW SUPPLY FAN | 0.340048 |
| SPLIT OFFICE SUPPLY FAN | 0.407697 |
| SPLIT GNE SUPPLY FAN | 0.300322 |
| SPLIT GN1 SUPPLY FAN | 0.268785 |
| SPLIT GN2 SUPPLY FAN | 0.268068 |
| SPLIT GS1 SUPPLY FAN | 0.305585 |
| SPLIT GS2 SUPPLY FAN | 0.307430 |
| SPLIT MSW SUPPLY FAN | 0.929701 |
| SPLIT MNW SUPPLY FAN | 0.876390 |
| SPLIT MSE SUPPLY FAN | 0.799081 |
| SPLIT MNE SUPPLY FAN | 0.747492 |
| SPLIT MN1 SUPPLY FAN | 0.668867 |
| SPLIT MN2 SUPPLY FAN | 0.666760 |
| SPLIT MS1 SUPPLY FAN | 0.729513 |
| SPLIT MS2 SUPPLY FAN | 0.727230 |
| SPLIT TSW SUPPLY FAN | 0.505275 |
| SPLIT TNW SUPPLY FAN | 0.489558 |
| SPLIT TSE SUPPLY FAN | 0.411133 |
| SPLIT TNE SUPPLY FAN | 0.395534 |
| SPLIT TN1 SUPPLY FAN | 0.371050 |
| SPLIT TN2 SUPPLY FAN | 0.368214 |
| SPLIT TS1 SUPPLY FAN | 0.389101 |
| SPLIT TS2 SUPPLY FAN | 0.386264 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.372722 |
| G NW APARTMENT DIRECT AIR | 0.340048 |
| OFFICE DIRECT AIR | 0.407697 |
| G NE APARTMENT DIRECT AIR | 0.300322 |
| G N1 APARTMENT DIRECT AIR | 0.268785 |
| G N2 APARTMENT DIRECT AIR | 0.268068 |
| G S1 APARTMENT DIRECT AIR | 0.305585 |
| G S2 APARTMENT DIRECT AIR | 0.307430 |
| M SW APARTMENT DIRECT AIR | 0.929701 |
| M NW APARTMENT DIRECT AIR | 0.876390 |
| M SE APARTMENT DIRECT AIR | 0.799081 |
| M NE APARTMENT DIRECT AIR | 0.747492 |
| M N1 APARTMENT DIRECT AIR | 0.668867 |
| M N2 APARTMENT DIRECT AIR | 0.666760 |
| M S1 APARTMENT DIRECT AIR | 0.729513 |
| M S2 APARTMENT DIRECT AIR | 0.727230 |
| T SW APARTMENT DIRECT AIR | 0.505275 |
| T NW APARTMENT DIRECT AIR | 0.489558 |
| T SE APARTMENT DIRECT AIR | 0.411133 |
| T NE APARTMENT DIRECT AIR | 0.395534 |
| T N1 APARTMENT DIRECT AIR | 0.371050 |
| T N2 APARTMENT DIRECT AIR | 0.368214 |
| T S1 APARTMENT DIRECT AIR | 0.389101 |
| T S2 APARTMENT DIRECT AIR | 0.386264 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.372722 | 0.372722 | 0.372722 | 0.372722 | 0.372722 | 0.372722 | 1.00 | 1.00 | 0.372722 |
| SPLIT GNW | 0.340048 | 0.340048 | 0.340048 | 0.340048 | 0.340048 | 0.340048 | 1.00 | 1.00 | 0.340048 |
| SPLIT OFFICE | 0.407697 | 0.407697 | 0.407697 | 0.407697 | 0.407697 | 0.407697 | 1.00 | 1.000000 | 0.407697 |
| SPLIT GNE | 0.300322 | 0.300322 | 0.300322 | 0.300322 | 0.300322 | 0.300322 | 1.00 | 1.00 | 0.300322 |
| SPLIT GN1 | 0.268785 | 0.268785 | 0.268785 | 0.268785 | 0.268785 | 0.268785 | 1.00 | 1.00 | 0.268785 |
| SPLIT GN2 | 0.268068 | 0.268068 | 0.268068 | 0.268068 | 0.268068 | 0.268068 | 1.00 | 1.00 | 0.268068 |
| SPLIT GS1 | 0.305585 | 0.305585 | 0.305585 | 0.305585 | 0.305585 | 0.305585 | 1.00 | 1.00 | 0.305585 |
| SPLIT GS2 | 0.307430 | 0.307430 | 0.307430 | 0.307430 | 0.307430 | 0.307430 | 1.00 | 1.00 | 0.307430 |
| SPLIT MSW | 0.929701 | 0.929701 | 0.929701 | 0.929701 | 0.929701 | 0.929701 | 1.00 | 1.00 | 0.929701 |
| SPLIT MNW | 0.876390 | 0.876390 | 0.876390 | 0.876390 | 0.876390 | 0.876390 | 1.00 | 1.00 | 0.876390 |
| SPLIT MSE | 0.799081 | 0.799081 | 0.799081 | 0.799081 | 0.799081 | 0.799081 | 1.00 | 1.00 | 0.799081 |
| SPLIT MNE | 0.747492 | 0.747492 | 0.747492 | 0.747492 | 0.747492 | 0.747492 | 1.00 | 1.00 | 0.747492 |
| SPLIT MN1 | 0.668867 | 0.668867 | 0.668867 | 0.668867 | 0.668867 | 0.668867 | 1.00 | 1.00 | 0.668867 |
| SPLIT MN2 | 0.666760 | 0.666760 | 0.666760 | 0.666760 | 0.666760 | 0.666760 | 1.00 | 1.00 | 0.666760 |
| SPLIT MS1 | 0.729513 | 0.729513 | 0.729513 | 0.729513 | 0.729513 | 0.729513 | 1.00 | 1.00 | 0.729513 |
| SPLIT MS2 | 0.727230 | 0.727230 | 0.727230 | 0.727230 | 0.727230 | 0.727230 | 1.00 | 1.00 | 0.727230 |
| SPLIT TSW | 0.505275 | 0.505275 | 0.505275 | 0.505275 | 0.505275 | 0.505275 | 1.00 | 1.00 | 0.505275 |
| SPLIT TNW | 0.489558 | 0.489558 | 0.489558 | 0.489558 | 0.489558 | 0.489558 | 1.00 | 1.00 | 0.489558 |
| SPLIT TSE | 0.411133 | 0.411133 | 0.411133 | 0.411133 | 0.411133 | 0.411133 | 1.00 | 1.00 | 0.411133 |
| SPLIT TNE | 0.395534 | 0.395534 | 0.395534 | 0.395534 | 0.395534 | 0.395534 | 1.00 | 1.00 | 0.395534 |
| SPLIT TN1 | 0.371050 | 0.371050 | 0.371050 | 0.371050 | 0.371050 | 0.371050 | 1.00 | 1.000000 | 0.371050 |
| SPLIT TN2 | 0.368214 | 0.368214 | 0.368214 | 0.368214 | 0.368214 | 0.368214 | 1.00 | 1.00 | 0.368214 |
| SPLIT TS1 | 0.389101 | 0.389101 | 0.389101 | 0.389101 | 0.389101 | 0.389101 | 1.00 | 1.00 | 0.389101 |
| SPLIT TS2 | 0.386264 | 0.386264 | 0.386264 | 0.386264 | 0.386264 | 0.386264 | 1.00 | 1.00 | 0.386264 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.372722 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.340048 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.407697 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.300322 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.268785 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.268068 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.305585 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.307430 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.929701 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.876390 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.799081 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.747492 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.668867 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.666760 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.729513 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.727230 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.505275 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.489558 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.411133 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.395534 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.371050 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.368214 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.389101 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.386264 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.372722 | 0.372722 | 0.372722 | 0.372722 | 6169.87 | 9787.55 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.340048 | 0.340048 | 0.340048 | 0.340048 | 5629.00 | 9071.43 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.407697 | 0.407697 | 0.407697 | 0.407697 | 6748.83 | 11312.08 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.300322 | 0.300322 | 0.300322 | 0.300322 | 4971.40 | 8200.82 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.268785 | 0.268785 | 0.268785 | 0.268785 | 4449.35 | 7509.63 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.268068 | 0.268068 | 0.268068 | 0.268068 | 4437.48 | 7493.91 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.305585 | 0.305585 | 0.305585 | 0.305585 | 5058.52 | 8316.16 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.307430 | 0.307430 | 0.307430 | 0.307430 | 5089.05 | 8356.57 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.929701 | 0.929701 | 0.929701 | 0.929701 | 15389.86 | 23614.10 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.876390 | 0.876390 | 0.876390 | 0.876390 | 14507.37 | 22445.40 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.799081 | 0.799081 | 0.799081 | 0.799081 | 13227.63 | 20751.33 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.747492 | 0.747492 | 0.747492 | 0.747492 | 12373.65 | 19620.42 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.668867 | 0.668867 | 0.668867 | 0.668867 | 11072.12 | 17896.90 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.666760 | 0.666760 | 0.666760 | 0.666760 | 11037.24 | 17850.73 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.729513 | 0.729513 | 0.729513 | 0.729513 | 12076.04 | 19226.28 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.727230 | 0.727230 | 0.727230 | 0.727230 | 12038.25 | 19176.25 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.505275 | 0.505275 | 0.505275 | 0.505275 | 8364.09 | 12693.25 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.489558 | 0.489558 | 0.489558 | 0.489558 | 8103.93 | 12348.63 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.411133 | 0.411133 | 0.411133 | 0.411133 | 6805.71 | 10629.93 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.395534 | 0.395534 | 0.395534 | 0.395534 | 6547.48 | 10287.90 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.371050 | 0.371050 | 0.371050 | 0.371050 | 6142.20 | 9751.04 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.368214 | 0.368214 | 0.368214 | 0.368214 | 6095.24 | 9688.88 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.389101 | 0.389101 | 0.389101 | 0.389101 | 6441.00 | 10146.78 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.386264 | 0.386264 | 0.386264 | 0.386264 | 6394.04 | 10084.61 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.372722 | 6169.87 | 0.800655 |
| SPLIT GNW COOLING COIL | 0.340048 | 5629.00 | 0.800655 |
| SPLIT OFFICE COOLING COIL | 0.407697 | 6748.83 | 0.800655 |
| SPLIT GNE COOLING COIL | 0.300322 | 4971.40 | 0.800655 |
| SPLIT GN1 COOLING COIL | 0.268785 | 4449.35 | 0.800655 |
| SPLIT GN2 COOLING COIL | 0.268068 | 4437.48 | 0.800655 |
| SPLIT GS1 COOLING COIL | 0.305585 | 5058.52 | 0.800655 |
| SPLIT GS2 COOLING COIL | 0.307430 | 5089.05 | 0.800655 |
| SPLIT MSW COOLING COIL | 0.929701 | 15389.86 | 0.800655 |
| SPLIT MNW COOLING COIL | 0.876390 | 14507.37 | 0.800655 |
| SPLIT MSE COOLING COIL | 0.799081 | 13227.63 | 0.800655 |
| SPLIT MNE COOLING COIL | 0.747492 | 12373.65 | 0.800655 |
| SPLIT MN1 COOLING COIL | 0.668867 | 11072.12 | 0.800655 |
| SPLIT MN2 COOLING COIL | 0.666760 | 11037.24 | 0.800655 |
| SPLIT MS1 COOLING COIL | 0.729513 | 12076.04 | 0.800655 |
| SPLIT MS2 COOLING COIL | 0.727230 | 12038.25 | 0.800655 |
| SPLIT TSW COOLING COIL | 0.505275 | 8364.09 | 0.800655 |
| SPLIT TNW COOLING COIL | 0.489558 | 8103.93 | 0.800655 |
| SPLIT TSE COOLING COIL | 0.411133 | 6805.71 | 0.800655 |
| SPLIT TNE COOLING COIL | 0.395534 | 6547.48 | 0.800655 |
| SPLIT TN1 COOLING COIL | 0.371050 | 6142.20 | 0.800655 |
| SPLIT TN2 COOLING COIL | 0.368214 | 6095.24 | 0.800655 |
| SPLIT TS1 COOLING COIL | 0.389101 | 6441.00 | 0.800655 |
| SPLIT TS2 COOLING COIL | 0.386264 | 6394.04 | 0.800655 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 9787.55 |
| SPLIT GNW HEATING COIL | 9071.43 |
| SPLIT OFFICE HEATING COIL | 11312.08 |
| SPLIT GNE HEATING COIL | 8200.82 |
| SPLIT GN1 HEATING COIL | 7509.63 |
| SPLIT GN2 HEATING COIL | 7493.91 |
| SPLIT GS1 HEATING COIL | 8316.16 |
| SPLIT GS2 HEATING COIL | 8356.57 |
| SPLIT MSW HEATING COIL | 23614.10 |
| SPLIT MNW HEATING COIL | 22445.40 |
| SPLIT MSE HEATING COIL | 20751.33 |
| SPLIT MNE HEATING COIL | 19620.42 |
| SPLIT MN1 HEATING COIL | 17896.90 |
| SPLIT MN2 HEATING COIL | 17850.73 |
| SPLIT MS1 HEATING COIL | 19226.28 |
| SPLIT MS2 HEATING COIL | 19176.25 |
| SPLIT TSW HEATING COIL | 12693.25 |
| SPLIT TNW HEATING COIL | 12348.63 |
| SPLIT TSE HEATING COIL | 10629.93 |
| SPLIT TNE HEATING COIL | 10287.90 |
| SPLIT TN1 HEATING COIL | 9751.04 |
| SPLIT TN2 HEATING COIL | 9688.88 |
| SPLIT TS1 HEATING COIL | 10146.78 |
| SPLIT TS2 HEATING COIL | 10084.61 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 5.40 | -2.00 | -14.60 | -16.90 | -11.50 | -6.20 | 4.00 | 13.40 | 18.00 | 19.70 | 17.90 | 12.30 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | International Falls Intl Ap MN USA TMY3 WMO#=727470 | 48.57 | -93.40 | -6.00 | 359.00 | 97086 | 1.1539 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 3.29 | 36.60 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 6.623E-005 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 4207.86524 | 5049.43828 | 0.31060 | 0.37272 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 3093.80779 | 3712.56935 | 0.13911 | 0.16694 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3848.11909 | 4617.74291 | 0.28337 | 0.34005 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 2953.40103 | 3544.08124 | 0.13280 | 0.15936 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4538.43353 | 5446.12023 | 0.33975 | 0.40770 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.28000 | 1.27140E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 3702.55385 | 4443.06462 | 0.16648 | 0.19978 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 3407.87305 | 4089.44766 | 0.25027 | 0.30032 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 2943.80436 | 3532.56523 | 0.13237 | 0.15884 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 3059.90297 | 3671.88356 | 0.22399 | 0.26879 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 1946.05229 | 2335.26275 | 8.75053E-002 | 0.10501 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 3051.93220 | 3662.31864 | 0.22339 | 0.26807 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 1945.78707 | 2334.94448 | 8.74934E-002 | 0.10499 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3466.39164 | 4159.66996 | 0.25465 | 0.30559 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 2088.02467 | 2505.62960 | 9.38885E-002 | 0.11267 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3486.67410 | 4184.00892 | 0.25619 | 0.30743 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 2099.54341 | 2519.45210 | 9.44065E-002 | 0.11329 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 10454.57114 | 12545.48537 | 0.77475 | 0.92970 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 4991.47791 | 5989.77349 | 0.22443 | 0.26932 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 9862.28478 | 11834.74174 | 0.73033 | 0.87639 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 4659.80400 | 5591.76481 | 0.20952 | 0.25143 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 9008.10518 | 10809.72621 | 0.66590 | 0.79908 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 4968.81303 | 5962.57564 | 0.22341 | 0.26809 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 8438.32746 | 10125.99295 | 0.62291 | 0.74749 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 4637.14663 | 5564.57595 | 0.20850 | 0.25020 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 7572.07801 | 9086.49362 | 0.55739 | 0.66887 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 2584.35503 | 3101.22604 | 0.11620 | 0.13945 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 7548.66561 | 9058.39873 | 0.55563 | 0.66676 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 2583.79894 | 3100.55873 | 0.11618 | 0.13942 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 8240.72717 | 9888.87260 | 0.60793 | 0.72951 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 2909.97015 | 3491.96418 | 0.13084 | 0.15701 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 8215.59064 | 9858.70876 | 0.60603 | 0.72723 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 2909.42022 | 3491.30426 | 0.13082 | 0.15698 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5675.49815 | 6810.59778 | 0.42106 | 0.50527 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 4081.32845 | 4897.59414 | 0.18350 | 0.22020 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 5501.82486 | 6602.18983 | 0.40797 | 0.48956 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 3896.76618 | 4676.11941 | 0.17521 | 0.21025 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4635.45428 | 5562.54513 | 0.34261 | 0.41113 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 4064.43829 | 4877.32595 | 0.18274 | 0.21929 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 4461.79937 | 5354.15925 | 0.32961 | 0.39553 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 3879.84728 | 4655.81673 | 0.17445 | 0.20934 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 4191.10675 | 5029.32809 | 0.30921 | 0.37105 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 2628.30849 | 3153.97019 | 0.11818 | 0.14182 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 4159.79783 | 4991.75740 | 0.30684 | 0.36821 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 2627.86941 | 3153.44329 | 0.11816 | 0.14179 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4391.35636 | 5269.62763 | 0.32425 | 0.38910 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 2813.10291 | 3375.72349 | 0.12649 | 0.15178 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4359.97932 | 5231.97518 | 0.32189 | 0.38626 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26400 | 1.27174E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 2812.66872 | 3375.20247 | 0.12647 | 0.15176 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -32.70000 | 1.83376E-004 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4896.46 | 0.37272 | 0.37272 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 5277.60 | 0.16694 | 0.16694 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4468.41 | 0.34005 | 0.34005 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 5111.57 | 0.15936 | 0.15936 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5243.64 | 0.40770 | 0.40770 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 6755.49 | 0.19978 | 0.19978 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 3946.76 | 0.30032 | 0.30032 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 5100.22 | 0.15884 | 0.15884 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3532.49 | 0.26879 | 0.26879 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 3920.36 | 0.10501 | 0.10501 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3523.04 | 0.26807 | 0.26807 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 3920.05 | 0.10499 | 0.10499 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 4016.28 | 0.30559 | 0.30559 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 4088.24 | 0.11267 | 0.11267 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 4040.33 | 0.30743 | 0.30743 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 4101.86 | 0.11329 | 0.11329 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 12209.82 | 0.92970 | 0.92970 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 9140.68 | 0.26932 | 0.26932 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 11509.45 | 0.87639 | 0.87639 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 8748.49 | 0.25143 | 0.25143 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 10496.48 | 0.79908 | 0.79908 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 9113.88 | 0.26809 | 0.26809 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 9819.92 | 0.74749 | 0.74749 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 8721.70 | 0.25020 | 0.25020 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 8789.80 | 0.66887 | 0.66887 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 6294.26 | 0.13945 | 0.13945 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 8762.12 | 0.66676 | 0.66676 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 6293.60 | 0.13942 | 0.13942 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9585.17 | 0.72951 | 0.72951 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 6679.28 | 0.15701 | 0.15701 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9555.28 | 0.72723 | 0.72723 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 6678.63 | 0.15698 | 0.15698 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6635.38 | 0.50527 | 0.50527 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 6445.32 | 0.22020 | 0.22020 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 6429.57 | 0.48956 | 0.48956 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 6227.08 | 0.21025 | 0.21025 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 5402.54 | 0.41113 | 0.41113 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 6425.35 | 0.21929 | 0.21929 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 5197.41 | 0.39553 | 0.39553 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 6207.07 | 0.20934 | 0.20934 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 4876.55 | 0.37105 | 0.37105 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 4727.12 | 0.14182 | 0.14182 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 4839.40 | 0.36821 | 0.36821 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 4726.60 | 0.14179 | 0.14179 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5113.65 | 0.38910 | 0.38910 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 4945.64 | 0.15178 | 0.15178 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5076.47 | 0.38626 | 0.38626 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 4945.12 | 0.15176 | 0.15176 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37272 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34005 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.40770 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30032 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26879 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26807 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30559 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30743 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.92970 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.87639 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.79908 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.74749 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66887 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66676 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.72951 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.72723 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.50527 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.48956 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.41113 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.39553 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37105 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36821 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38910 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38626 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37272 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37272 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37272 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37272 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37272 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.37272 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34005 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34005 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34005 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34005 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34005 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.34005 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.40770 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.40770 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.40770 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.40770 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.40770 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.40770 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30032 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30032 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30032 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30032 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30032 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.30032 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26879 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26879 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26879 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26879 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26879 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26879 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26807 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26807 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26807 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26807 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26807 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26807 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30559 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30559 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30559 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30559 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30559 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30559 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30743 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30743 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30743 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30743 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30743 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30743 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.92970 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.92970 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.92970 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.92970 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92970 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.92970 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.87639 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.87639 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.87639 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.87639 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.87639 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.87639 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.79908 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.79908 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.79908 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.79908 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.79908 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.79908 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.74749 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.74749 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.74749 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.74749 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.74749 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.74749 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66887 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66887 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66887 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66887 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66887 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66887 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66676 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66676 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66676 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66676 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66676 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66676 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.72951 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.72951 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.72951 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.72951 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.72951 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.72951 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.72723 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.72723 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.72723 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.72723 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.72723 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.72723 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.50527 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.50527 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.50527 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.50527 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.50527 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.50527 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.48956 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.48956 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.48956 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.48956 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.48956 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.48956 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.41113 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.41113 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.41113 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.41113 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.41113 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.41113 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.39553 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.39553 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.39553 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.39553 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.39553 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.39553 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37105 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37105 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37105 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37105 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37105 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.37105 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36821 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36821 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36821 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36821 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36821 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36821 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38910 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38910 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38910 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38910 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38910 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.38910 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38626 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38626 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38626 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38626 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38626 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.38626 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.37272 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.34005 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.40770 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.30032 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.26879 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.26807 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.30559 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.30743 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.92970 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.87639 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.79908 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.74749 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.66887 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.66676 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.72951 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.72723 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.50527 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.48956 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.41113 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.39553 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.37105 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.36821 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.38910 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.38626 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37272 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37272 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37272 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37272 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37272 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6169.86997 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9787.54597 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37272 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37272 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6169.86997 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 9787.54597 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34005 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34005 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34005 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34005 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34005 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5628.99569 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9071.42705 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34005 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34005 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5628.99569 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 9071.42705 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.40770 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.40770 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.40770 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.40770 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.40770 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6748.82766 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11312.07631 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.40770 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.40770 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6748.82766 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 11312.07631 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30032 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30032 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30032 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30032 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30032 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4971.39885 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8200.82383 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30032 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30032 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4971.39885 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 8200.82383 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26879 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26879 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26879 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26879 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26879 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4449.35143 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7509.62719 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26879 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26879 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4449.35143 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 7509.62719 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26807 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26807 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26807 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26807 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26807 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4437.48040 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7493.91109 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26807 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26807 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4437.48040 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 7493.91109 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30559 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30559 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30559 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30559 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30559 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5058.52495 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8316.15801 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30559 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30559 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5058.52495 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 8316.15801 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30743 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30743 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30743 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30743 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30743 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5089.05340 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8356.57498 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30743 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30743 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5089.05340 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 8356.57498 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92970 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92970 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92970 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92970 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92970 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 15389.85775 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 23614.09559 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.92970 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.92970 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 15389.85775 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 23614.09559 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.87639 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.87639 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.87639 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.87639 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.87639 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14507.37268 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 22445.39940 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.87639 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.87639 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14507.37268 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 22445.39940 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.79908 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.79908 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.79908 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.79908 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.79908 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13227.62595 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20751.33357 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.79908 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.79908 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13227.62595 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 20751.33357 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.74749 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.74749 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.74749 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.74749 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.74749 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12373.64563 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 19620.42396 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.74749 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.74749 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12373.64563 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 19620.42396 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66887 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66887 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66887 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66887 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66887 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11072.11980 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17896.90195 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66887 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66887 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11072.11980 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 17896.90195 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66676 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66676 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66676 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66676 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66676 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11037.24302 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17850.72758 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66676 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66676 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11037.24302 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 17850.72758 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.72951 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.72951 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.72951 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.72951 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.72951 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12076.03608 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 19226.27800 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.72951 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.72951 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12076.03608 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 19226.27800 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.72723 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.72723 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.72723 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.72723 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.72723 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12038.24693 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 19176.24699 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.72723 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.72723 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12038.24693 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 19176.24699 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.50527 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.50527 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.50527 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.50527 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.50527 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8364.08740 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 12693.25229 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.50527 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.50527 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8364.08740 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 12693.25229 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.48956 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.48956 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.48956 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.48956 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.48956 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8103.92789 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 12348.62559 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.48956 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.48956 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8103.92789 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 12348.62559 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.41113 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.41113 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.41113 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.41113 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.41113 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6805.70758 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10629.93225 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.41113 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.41113 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6805.70758 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 10629.93225 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.39553 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.39553 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.39553 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.39553 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.39553 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6547.48486 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10287.90459 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.39553 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39553 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6547.48486 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 10287.90459 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37105 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37105 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37105 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37105 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37105 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6142.19758 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9751.04145 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37105 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37105 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6142.19758 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 9751.04145 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36821 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36821 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36821 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36821 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36821 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6095.24421 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9688.87765 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36821 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36821 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6095.24421 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 9688.87765 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38910 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38910 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38910 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38910 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38910 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6441.00072 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10146.78219 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38910 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38910 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6441.00072 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 10146.78219 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38626 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38626 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38626 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38626 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38626 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6394.04156 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10084.60963 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38626 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38626 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6394.04156 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 10084.60963 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 5877.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 5362.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 6429.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 4736.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 4238.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 4227.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 4819.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 4848.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 14661.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 13820.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 12601.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 11787.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 10547.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 10514.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 11504.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 11468.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 7968.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 7720.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 6483.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 6237.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 5851.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 5806.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 6136.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 6091.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.154 | 0.149 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.154 | 0.149 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.154 | 0.149 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.154 | 0.149 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 9.217E-002 | 9.015E-002 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 9.217E-002 | 9.015E-002 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 9.217E-002 | 9.015E-002 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.668 | 0.608 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 9.217E-002 | 9.015E-002 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.677 | 0.615 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.007 | 0.875 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.163 | 0.158 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 3.003E-002 | 2.981E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3097_SHGC_0.45 | N/A | 1.759 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0527329073E-007 | 4.6905092321E-007 | Pass | Pass | 1.9481924449E-002 | 1.8322938701E-002 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.9145344767E-007 | 1.1673235453E-006 | Pass | Pass | 9.2143735212E-003 | 8.2000479796E-003 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 1.9183868827E-008 | 1.0741423908E-007 | Pass | Pass | 3.4168258200E-002 | 3.8059670565E-002 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.8799037624E-007 | 1.1418423535E-006 | Pass | Pass | 8.9573391291E-003 | 9.0365956727E-003 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9737453617E-007 | 8.0143918311E-007 | Pass | Pass | 9.6765913808E-003 | 1.1207906474E-002 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9732876718E-007 | 8.0107704342E-007 | Pass | Pass | 9.6697870052E-003 | 1.1230402482E-002 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.4300576763E-008 | 1.9154885604E-007 | Pass | Pass | 4.0631066888E-002 | 4.7440782806E-002 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.0957826737E-008 | 2.7012892469E-007 | Pass | Pass | 2.8225140431E-002 | 3.0685716791E-002 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.9051330961E-008 | 2.3836444385E-007 | Pass | Pass | 5.4850652333E-002 | 5.7643362443E-002 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.0582908235E-007 | 8.2777719011E-007 | Pass | Pass | 1.5865365598E-002 | 1.4417784415E-002 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 6.2270992881E-008 | 2.5691309708E-007 | Pass | Pass | 7.6553917809E-002 | 0.1651544465 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.0053610165E-007 | 7.8881467969E-007 | Pass | Pass | 1.4766199468E-002 | 1.5907693073E-002 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0988173541E-007 | 4.5221647440E-007 | Pass | Pass | 1.8944298398E-002 | 2.2024388051E-002 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0984576323E-007 | 4.5178312077E-007 | Pass | Pass | 1.8893968221E-002 | 2.2058584302E-002 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3457308343E-008 | 1.1629277601E-007 | Pass | Pass | 0.2133602327 | 0.7278481307 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3408698757E-008 | 1.1602962435E-007 | Pass | Pass | 0.2143567310 | 0.6896707027 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.5694182665E-007 | 6.6606619520E-007 | Pass | Pass | 2.7407902059E-002 | 2.7361123720E-002 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.5624712494E-007 | 1.4044840535E-006 | Pass | Pass | 1.2206648774E-002 | 9.8542110529E-003 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6246105022E-007 | 7.0106561370E-007 | Pass | Pass | 2.9513460208E-002 | 3.0623678150E-002 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.5046746934E-007 | 1.3599283466E-006 | Pass | Pass | 1.1138514516E-002 | 1.1075952522E-002 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5653422687E-007 | 1.0295748566E-006 | Pass | Pass | 1.0841937101E-002 | 1.0699021855E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5657722004E-007 | 1.0292074275E-006 | Pass | Pass | 1.0783734259E-002 | 1.0766157696E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 8.3826651398E-008 | 3.4660131853E-007 | Pass | Pass | 0.1422381074 | 0.3946963572 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 8.4118743576E-008 | 3.4809047831E-007 | Pass | Pass | 0.1473179844 | 0.4709129657 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 1.7740830889E-002 | 1.1570248899E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.4097799655 | 1.4174839242 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 8.9671125559E-003 | 6.5338733301E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1807.47 | 209.45 | 0.00 | 24.82 | 525.93 | 2567.67 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
| INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 0.00 | 0 | |||
| Feb | 0.00 | 0 | |||
| Mar | 12.00 | 13 | |||
| Apr | 16.00 | 23 | |||
| May | 0.00 | 0 | |||
| Jun | 190.00 | 53 | |||
| Jul | 136.00 | 41 | |||
| Aug | 87.00 | 42 | |||
| Sep | 0.00 | 0 | |||
| Oct | 0.00 | 0 | |||
| Nov | 0.00 | 0 | |||
| Dec | 0.00 | 0 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.150 | 0.154 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.150 | 0.154 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.150 | 0.154 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.150 | 0.154 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.091 | 0.092 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.091 | 0.092 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.091 | 0.092 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.608 | 0.668 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.091 | 0.092 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.615 | 0.677 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.875 | 1.007 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.30 | 0.159 | 0.163 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.30 | 0.159 | 0.163 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.030 | 0.030 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 1.759 | 0.451 | 0.452 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 1.759 | 0.451 | 0.452 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 1.759 | 0.451 | 0.452 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 1.759 | 0.451 | 0.452 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 1.759 | 0.451 | 0.452 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.3097_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 1.759 | 0.451 | 0.452 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.3097_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 1.759 | 0.451 | 0.452 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.3097_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 1.759 | 0.451 | 0.452 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.3097_SHGC_0.45 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 1.759 | 0.451 | 0.452 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.3097_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 1.759 | 0.451 | 0.452 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 1.759 | 0.451 | 0.452 | |||||||||||||||||
| North Total or Average | 112.97 | 1.759 | 0.451 | 0.452 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 1.759 | 0.451 | 0.452 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.52 | 83.52 | 49.91 | |
| Exterior Lighting Total | 3183.33 | 49.91 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6169.87 | 4939.94 | 1229.93 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5629.00 | 4506.89 | 1122.11 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6748.83 | 5403.48 | 1345.34 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4971.40 | 3980.38 | 991.02 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4449.35 | 3562.40 | 886.95 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4437.48 | 3552.89 | 884.59 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5058.52 | 4050.13 | 1008.39 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5089.05 | 4074.58 | 1014.48 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 15389.86 | 12321.97 | 3067.89 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14507.37 | 11615.40 | 2891.97 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13227.63 | 10590.77 | 2636.86 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12373.65 | 9907.02 | 2466.62 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11072.12 | 8864.95 | 2207.17 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11037.24 | 8837.03 | 2200.22 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12076.04 | 9668.74 | 2407.29 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12038.25 | 9638.49 | 2399.76 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8364.09 | 6696.75 | 1667.34 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8103.93 | 6488.45 | 1615.48 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6805.71 | 5449.03 | 1356.68 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6547.48 | 5242.28 | 1305.21 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6142.20 | 4917.78 | 1224.41 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6095.24 | 4880.19 | 1215.05 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6441.00 | 5157.02 | 1283.98 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6394.04 | 5119.42 | 1274.62 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 5877.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNW COOLING COIL | 5362.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT OFFICE COOLING COIL | 6429.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNE COOLING COIL | 4736.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN1 COOLING COIL | 4238.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN2 COOLING COIL | 4227.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS1 COOLING COIL | 4819.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS2 COOLING COIL | 4848.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSW COOLING COIL | 14661.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNW COOLING COIL | 13820.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSE COOLING COIL | 12601.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNE COOLING COIL | 11787.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN1 COOLING COIL | 10547.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN2 COOLING COIL | 10514.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS1 COOLING COIL | 11504.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS2 COOLING COIL | 11468.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSW COOLING COIL | 7968.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNW COOLING COIL | 7720.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSE COOLING COIL | 6483.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNE COOLING COIL | 6237.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN1 COOLING COIL | 5851.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN2 COOLING COIL | 5806.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS1 COOLING COIL | 6136.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS2 COOLING COIL | 6091.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 9787.55 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 9071.43 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 11312.08 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 8200.82 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 7509.63 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 7493.91 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 8316.16 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 8356.57 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 23614.10 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 22445.40 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 20751.33 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 19620.42 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 17896.90 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 17850.73 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 19226.28 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 19176.25 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 12693.25 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 12348.63 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 10629.93 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 10287.90 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 9751.04 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 9688.88 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 10146.78 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 10084.61 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 417.49 | 1120.11 | 1.00 | 1.76 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 380.89 | 1120.11 | 1.00 | 1.81 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 456.66 | 1120.11 | 1.00 | 1.71 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 336.39 | 1120.11 | 1.00 | 1.90 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 301.07 | 1120.11 | 1.00 | 1.98 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 300.27 | 1120.11 | 1.00 | 1.98 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 342.29 | 1120.11 | 1.00 | 1.88 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 344.35 | 1120.11 | 1.00 | 1.88 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.93 | 1041.37 | 1120.11 | 1.00 | 1.39 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.88 | 981.65 | 1120.11 | 1.00 | 1.41 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.80 | 895.06 | 1120.11 | 1.00 | 1.43 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.75 | 837.27 | 1120.11 | 1.00 | 1.45 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 749.20 | 1120.11 | 1.00 | 1.49 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 746.84 | 1120.11 | 1.00 | 1.49 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.73 | 817.13 | 1120.11 | 1.00 | 1.46 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.73 | 814.58 | 1120.11 | 1.00 | 1.46 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.51 | 565.96 | 1120.11 | 1.00 | 1.60 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.49 | 548.36 | 1120.11 | 1.00 | 1.62 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 460.51 | 1120.11 | 1.00 | 1.70 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.40 | 443.04 | 1120.11 | 1.00 | 1.72 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 415.62 | 1120.11 | 1.00 | 1.76 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 412.44 | 1120.11 | 1.00 | 1.76 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 435.83 | 1120.11 | 1.00 | 1.73 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 432.66 | 1120.11 | 1.00 | 1.74 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 4207.87 | 5049.44 | 57.22 | 0.311 | 0.373 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 25.26 | 0.01272 | 0.026 | 0.00 |
| G NW APARTMENT | 3848.12 | 4617.74 | 52.33 | 0.283 | 0.340 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 25.26 | 0.01272 | 0.026 | 0.00 |
| OFFICE | 4538.43 | 5446.12 | 61.71 | 0.340 | 0.408 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.90 | 23.90 | 0.00815 | 23.28 | 0.01271 | 0.038 | 0.00 |
| G NE APARTMENT | 3407.87 | 4089.45 | 46.34 | 0.250 | 0.300 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00830 | 25.26 | 0.01272 | 0.026 | 0.00 |
| G N1 APARTMENT | 3059.90 | 3671.88 | 41.61 | 0.224 | 0.269 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00828 | 25.26 | 0.01272 | 0.026 | 0.00 |
| G N2 APARTMENT | 3051.93 | 3662.32 | 41.50 | 0.223 | 0.268 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00828 | 25.26 | 0.01272 | 0.026 | 0.00 |
| G S1 APARTMENT | 3466.39 | 4159.67 | 47.14 | 0.255 | 0.306 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00826 | 25.26 | 0.01272 | 0.026 | 0.00 |
| G S2 APARTMENT | 3486.67 | 4184.01 | 47.41 | 0.256 | 0.307 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00826 | 25.26 | 0.01272 | 0.026 | 0.00 |
| M SW APARTMENT | 10454.57 | 12545.49 | 142.16 | 0.775 | 0.930 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M NW APARTMENT | 9862.28 | 11834.74 | 134.11 | 0.730 | 0.876 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M SE APARTMENT | 9008.11 | 10809.73 | 122.49 | 0.666 | 0.799 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00827 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M NE APARTMENT | 8438.33 | 10125.99 | 114.74 | 0.623 | 0.747 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00828 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M N1 APARTMENT | 7572.08 | 9086.49 | 102.96 | 0.557 | 0.669 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M N2 APARTMENT | 7548.67 | 9058.40 | 102.65 | 0.556 | 0.667 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M S1 APARTMENT | 8240.73 | 9888.87 | 112.06 | 0.608 | 0.730 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 25.26 | 0.01272 | 0.052 | 0.00 |
| M S2 APARTMENT | 8215.59 | 9858.71 | 111.71 | 0.606 | 0.727 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 25.26 | 0.01272 | 0.052 | 0.00 |
| T SW APARTMENT | 5675.50 | 6810.60 | 77.17 | 0.421 | 0.505 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T NW APARTMENT | 5501.82 | 6602.19 | 74.81 | 0.408 | 0.490 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T SE APARTMENT | 4635.45 | 5562.55 | 63.03 | 0.343 | 0.411 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00831 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T NE APARTMENT | 4461.80 | 5354.16 | 60.67 | 0.330 | 0.396 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00831 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T N1 APARTMENT | 4191.11 | 5029.33 | 56.99 | 0.309 | 0.371 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T N2 APARTMENT | 4159.80 | 4991.76 | 56.56 | 0.307 | 0.368 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T S1 APARTMENT | 4391.36 | 5269.63 | 59.71 | 0.324 | 0.389 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 25.26 | 0.01272 | 0.026 | 0.00 |
| T S2 APARTMENT | 4359.98 | 5231.98 | 59.29 | 0.322 | 0.386 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 25.26 | 0.01272 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 3093.81 | 3712.57 | 42.07 | 0.139 | 0.167 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00771 | -32.70 | 0.00018 | 0.026 | 0.00 |
| G NW APARTMENT | 2953.40 | 3544.08 | 40.16 | 0.133 | 0.159 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00776 | -32.70 | 0.00018 | 0.026 | 0.00 |
| OFFICE | 3702.55 | 4443.06 | 50.35 | 0.166 | 0.200 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00776 | -32.70 | 0.00018 | 0.038 | 0.00 |
| G NE APARTMENT | 2943.80 | 3532.57 | 40.03 | 0.132 | 0.159 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00776 | -32.70 | 0.00018 | 0.026 | 0.00 |
| G N1 APARTMENT | 1946.05 | 2335.26 | 26.46 | 0.088 | 0.105 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00783 | -32.70 | 0.00018 | 0.026 | 0.00 |
| G N2 APARTMENT | 1945.79 | 2334.94 | 26.46 | 0.087 | 0.105 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00783 | -32.70 | 0.00018 | 0.026 | 0.00 |
| G S1 APARTMENT | 2088.02 | 2505.63 | 28.39 | 0.094 | 0.113 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00773 | -32.70 | 0.00018 | 0.026 | 0.00 |
| G S2 APARTMENT | 2099.54 | 2519.45 | 28.55 | 0.094 | 0.113 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00773 | -32.70 | 0.00018 | 0.026 | 0.00 |
| M SW APARTMENT | 4991.48 | 5989.77 | 67.87 | 0.224 | 0.269 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00751 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M NW APARTMENT | 4659.80 | 5591.76 | 63.36 | 0.210 | 0.251 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00760 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M SE APARTMENT | 4968.81 | 5962.58 | 67.57 | 0.223 | 0.268 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00750 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M NE APARTMENT | 4637.15 | 5564.58 | 63.06 | 0.209 | 0.250 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00760 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M N1 APARTMENT | 2584.36 | 3101.23 | 35.14 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00766 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M N2 APARTMENT | 2583.80 | 3100.56 | 35.13 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00766 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M S1 APARTMENT | 2909.97 | 3491.96 | 39.57 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00749 | -32.70 | 0.00018 | 0.052 | 0.00 |
| M S2 APARTMENT | 2909.42 | 3491.30 | 39.56 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00749 | -32.70 | 0.00018 | 0.052 | 0.00 |
| T SW APARTMENT | 4081.33 | 4897.59 | 55.50 | 0.184 | 0.220 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00760 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T NW APARTMENT | 3896.77 | 4676.12 | 52.99 | 0.175 | 0.210 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00766 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T SE APARTMENT | 4064.44 | 4877.33 | 55.27 | 0.183 | 0.219 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00759 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T NE APARTMENT | 3879.85 | 4655.82 | 52.76 | 0.174 | 0.209 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00765 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T N1 APARTMENT | 2628.31 | 3153.97 | 35.74 | 0.118 | 0.142 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T N2 APARTMENT | 2627.87 | 3153.44 | 35.73 | 0.118 | 0.142 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T S1 APARTMENT | 2813.10 | 3375.72 | 38.25 | 0.126 | 0.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00764 | -32.70 | 0.00018 | 0.026 | 0.00 |
| T S2 APARTMENT | 2812.67 | 3375.20 | 38.25 | 0.126 | 0.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00764 | -32.70 | 0.00018 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.37 | 0.37 | 0.17 | 0.17 | 0.3727 | 0.3727 | 0.3727 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.34 | 0.34 | 0.16 | 0.16 | 0.3400 | 0.3400 | 0.3400 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.41 | 0.41 | 0.20 | 0.20 | 0.4077 | 0.4077 | 0.4077 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.30 | 0.30 | 0.16 | 0.16 | 0.3003 | 0.3003 | 0.3003 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.27 | 0.27 | 0.11 | 0.11 | 0.2688 | 0.2688 | 0.2688 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.27 | 0.27 | 0.10 | 0.10 | 0.2681 | 0.2681 | 0.2681 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.31 | 0.31 | 0.11 | 0.11 | 0.3056 | 0.3056 | 0.3056 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.31 | 0.31 | 0.11 | 0.11 | 0.3074 | 0.3074 | 0.3074 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.93 | 0.93 | 0.27 | 0.27 | 0.9297 | 0.9297 | 0.9297 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.88 | 0.88 | 0.25 | 0.25 | 0.8764 | 0.8764 | 0.8764 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.80 | 0.80 | 0.27 | 0.27 | 0.7991 | 0.7991 | 0.7991 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.75 | 0.75 | 0.25 | 0.25 | 0.7475 | 0.7475 | 0.7475 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.67 | 0.67 | 0.14 | 0.14 | 0.6689 | 0.6689 | 0.6689 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.67 | 0.67 | 0.14 | 0.14 | 0.6668 | 0.6668 | 0.6668 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.73 | 0.73 | 0.16 | 0.16 | 0.7295 | 0.7295 | 0.7295 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.73 | 0.73 | 0.16 | 0.16 | 0.7272 | 0.7272 | 0.7272 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.51 | 0.51 | 0.22 | 0.22 | 0.5053 | 0.5053 | 0.5053 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.49 | 0.49 | 0.21 | 0.21 | 0.4896 | 0.4896 | 0.4896 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.41 | 0.41 | 0.22 | 0.22 | 0.4111 | 0.4111 | 0.4111 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.40 | 0.40 | 0.21 | 0.21 | 0.3955 | 0.3955 | 0.3955 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.37 | 0.37 | 0.14 | 0.14 | 0.3711 | 0.3711 | 0.3711 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.37 | 0.37 | 0.14 | 0.14 | 0.3682 | 0.3682 | 0.3682 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.39 | 0.39 | 0.15 | 0.15 | 0.3891 | 0.3891 | 0.3891 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.39 | 0.39 | 0.15 | 0.15 | 0.3863 | 0.3863 | 0.3863 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6169.870 | 4939.939 | 0.372722 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6101.12 | 5592.36 | 0.372722 | 25.08 | 16.37 | 0.00854699 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.9635 | 24.00 | 0.00823485 | 42.4999 | 4207.87 | 0.00 | 6168.82 | 4826.39 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 9787.546 | 9787.546 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 9787.55 | 9787.55 | 0.372722 | 17.35 | 12.27 | 0.00718365 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.9635 | 21.10 | 0.00770760 | 47.4800 | 3093.81 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 5628.996 | 4506.885 | 0.340048 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5570.53 | 5073.73 | 0.340048 | 25.08 | 16.41 | 0.00858884 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 7.6326 | 24.00 | 0.00824768 | 42.5652 | 3848.12 | 0.00 | 5628.04 | 4403.29 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 9071.427 | 9071.427 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 9071.43 | 9071.43 | 0.340048 | 16.99 | 12.12 | 0.00718478 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 7.6326 | 21.10 | 0.00776333 | 47.8185 | 2953.40 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 6748.828 | 5403.484 | 0.407697 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 6703.00 | 6106.73 | 0.407697 | 24.84 | 16.31 | 0.00857789 | 12.80 | 11.22 | 0.00800000 | 23.28 | 0.01271395 | 19.08 | 9.3467 | 23.90 | 0.00811208 | 42.1255 | 4320.30 | 0.00 | 6747.68 | 5279.28 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 11312.076 | 11312.076 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 11312.08 | 11312.08 | 0.407697 | 16.07 | 11.61 | 0.00704888 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 9.3467 | 21.10 | 0.00775674 | 47.7789 | 3702.55 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 4971.399 | 3980.377 | 0.300322 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4928.07 | 4424.89 | 0.300322 | 25.08 | 16.49 | 0.00868390 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 8.6422 | 24.00 | 0.00830234 | 42.8438 | 3407.87 | 0.00 | 4970.55 | 3888.88 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 8200.824 | 8200.824 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8200.82 | 8200.82 | 0.300322 | 16.45 | 11.83 | 0.00710759 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 8.6422 | 21.10 | 0.00776261 | 47.8142 | 2943.80 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 4449.351 | 3562.397 | 0.268785 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4412.69 | 3946.24 | 0.268785 | 25.08 | 16.51 | 0.00871090 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 9.6562 | 24.00 | 0.00828267 | 42.7433 | 3059.90 | 0.00 | 4448.59 | 3480.51 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 7509.627 | 7509.627 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7509.63 | 7509.63 | 0.268785 | 15.90 | 11.59 | 0.00709508 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 9.6562 | 21.10 | 0.00783383 | 48.2464 | 1946.05 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 4437.480 | 3552.892 | 0.268068 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4401.07 | 3934.66 | 0.268068 | 25.08 | 16.51 | 0.00871293 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 9.6821 | 24.00 | 0.00828365 | 42.7483 | 3051.93 | 0.00 | 4436.73 | 3471.22 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 7493.911 | 7493.911 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7493.91 | 7493.91 | 0.268068 | 15.89 | 11.58 | 0.00709309 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 9.6821 | 21.10 | 0.00783381 | 48.2463 | 1945.79 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5058.525 | 4050.135 | 0.305585 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5010.73 | 4527.70 | 0.305585 | 25.09 | 16.45 | 0.00864166 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 8.4934 | 24.00 | 0.00826336 | 42.6451 | 3466.39 | 0.00 | 5057.66 | 3957.04 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 8316.158 | 8316.158 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8316.16 | 8316.16 | 0.305585 | 16.53 | 11.84 | 0.00708881 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 8.4934 | 21.10 | 0.00772976 | 47.6140 | 2088.02 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5089.053 | 4074.577 | 0.307430 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5040.62 | 4557.25 | 0.307430 | 25.08 | 16.45 | 0.00863793 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 8.4424 | 24.00 | 0.00826176 | 42.6370 | 3486.67 | 0.00 | 5088.19 | 3980.92 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 8356.575 | 8356.575 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8356.57 | 8356.57 | 0.307430 | 16.56 | 11.86 | 0.00709407 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 8.4424 | 21.10 | 0.00773130 | 47.6234 | 2099.54 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 15389.858 | 12321.971 | 0.929701 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 15196.94 | 14096.54 | 0.929701 | 25.08 | 16.30 | 0.00846925 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 5.5834 | 24.00 | 0.00821803 | 42.4142 | 20909.14 | 0.00 | 15387.24 | 12038.73 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 23614.096 | 23614.096 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 23614.10 | 23614.10 | 0.929701 | 18.09 | 12.48 | 0.00709712 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 5.5834 | 21.10 | 0.00750597 | 46.2542 | 9982.96 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 14507.373 | 11615.404 | 0.876390 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 14330.60 | 13252.03 | 0.876390 | 25.08 | 16.32 | 0.00848925 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 5.9231 | 24.00 | 0.00822304 | 42.4396 | 19724.57 | 0.00 | 14504.90 | 11348.41 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 22445.399 | 22445.399 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 22445.40 | 22445.40 | 0.876390 | 17.91 | 12.47 | 0.00716300 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 5.9231 | 21.10 | 0.00760244 | 46.8406 | 9319.61 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 13227.626 | 10590.768 | 0.799081 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 13082.37 | 11973.66 | 0.799081 | 25.08 | 16.38 | 0.00855670 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.4961 | 24.00 | 0.00826764 | 42.6671 | 18016.21 | 0.00 | 13225.37 | 10347.33 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 20751.334 | 20751.334 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 20751.33 | 20751.33 | 0.799081 | 17.60 | 12.21 | 0.00702831 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.4961 | 21.10 | 0.00750385 | 46.2413 | 9937.63 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 12373.646 | 9907.024 | 0.747492 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12244.30 | 11156.44 | 0.747492 | 25.08 | 16.40 | 0.00858629 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.9444 | 24.00 | 0.00827800 | 42.7199 | 16876.65 | 0.00 | 12371.54 | 9679.30 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 19620.424 | 19620.424 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 19620.42 | 19620.42 | 0.747492 | 17.36 | 12.17 | 0.00708554 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.9444 | 21.10 | 0.00760062 | 46.8295 | 9274.29 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 11072.120 | 8864.951 | 0.668867 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 10958.10 | 9973.56 | 0.668867 | 25.08 | 16.41 | 0.00859368 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 7.7608 | 24.00 | 0.00824672 | 42.5601 | 15144.16 | 0.00 | 11070.24 | 8661.18 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 17896.902 | 17896.902 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17896.90 | 17896.90 | 0.668867 | 16.92 | 11.99 | 0.00708048 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 7.7608 | 21.10 | 0.00766078 | 47.1942 | 5168.71 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 11037.243 | 8837.027 | 0.666760 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 10924.00 | 9939.30 | 0.666760 | 25.08 | 16.41 | 0.00859582 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 7.7853 | 24.00 | 0.00824786 | 42.5659 | 15097.33 | 0.00 | 11035.36 | 8633.90 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 17850.728 | 17850.728 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17850.73 | 17850.73 | 0.666760 | 16.91 | 11.99 | 0.00707858 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 7.7853 | 21.10 | 0.00766071 | 47.1938 | 5167.60 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 12076.036 | 9668.742 | 0.729513 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11942.57 | 10939.39 | 0.729513 | 25.08 | 16.37 | 0.00855144 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 7.1156 | 24.00 | 0.00823230 | 42.4867 | 16481.45 | 0.00 | 12073.98 | 9446.49 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 19226.278 | 19226.278 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 19226.28 | 19226.28 | 0.729513 | 17.27 | 12.02 | 0.00696859 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 7.1156 | 21.10 | 0.00748838 | 46.1458 | 5819.94 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 12038.247 | 9638.486 | 0.727230 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11905.64 | 10902.14 | 0.727230 | 25.08 | 16.38 | 0.00855351 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 7.1379 | 24.00 | 0.00823345 | 42.4926 | 16431.18 | 0.00 | 12036.20 | 9416.93 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 19176.247 | 19176.247 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 19176.25 | 19176.25 | 0.727230 | 17.26 | 12.02 | 0.00696687 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 7.1379 | 21.10 | 0.00748829 | 46.1452 | 5818.84 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 8364.087 | 6696.751 | 0.505275 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 8259.67 | 7657.74 | 0.505275 | 25.08 | 16.31 | 0.00847250 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 5.1367 | 24.00 | 0.00824264 | 42.5399 | 5675.50 | 0.00 | 8362.66 | 6542.82 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 12693.252 | 12693.252 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12693.25 | 12693.25 | 0.505275 | 18.33 | 12.69 | 0.00721496 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 5.1367 | 21.10 | 0.00759571 | 46.8018 | 4081.33 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 8103.928 | 6488.452 | 0.489558 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 8003.66 | 7413.66 | 0.489558 | 25.08 | 16.31 | 0.00847841 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 5.3016 | 24.00 | 0.00824109 | 42.5319 | 5501.82 | 0.00 | 8102.55 | 6339.31 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 12348.626 | 12348.626 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12348.63 | 12348.63 | 0.489558 | 18.25 | 12.69 | 0.00725973 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 5.3016 | 21.10 | 0.00765590 | 47.1672 | 3896.77 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 6805.708 | 5449.026 | 0.411133 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6734.60 | 6137.21 | 0.411133 | 25.08 | 16.40 | 0.00858538 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.3129 | 24.00 | 0.00830696 | 42.8677 | 4635.45 | 0.00 | 6804.55 | 5323.77 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 10629.932 | 10629.932 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10629.93 | 10629.93 | 0.411133 | 17.70 | 12.35 | 0.00712628 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.3129 | 21.10 | 0.00759412 | 46.7921 | 4064.44 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 6547.485 | 5242.278 | 0.395534 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6480.39 | 5895.23 | 0.395534 | 25.08 | 16.41 | 0.00859691 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.5619 | 24.00 | 0.00830754 | 42.8706 | 4461.80 | 0.00 | 6546.37 | 5121.78 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 10287.905 | 10287.905 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10287.90 | 10287.90 | 0.395534 | 17.57 | 12.33 | 0.00716423 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.5619 | 21.10 | 0.00765448 | 47.1586 | 3879.85 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 6142.198 | 4917.783 | 0.371050 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6074.28 | 5565.41 | 0.371050 | 25.09 | 16.37 | 0.00854993 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.9949 | 24.00 | 0.00823649 | 42.5080 | 4191.11 | 0.00 | 6141.15 | 4804.74 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 9751.041 | 9751.041 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9751.04 | 9751.04 | 0.371050 | 17.34 | 12.28 | 0.00720842 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.9949 | 21.10 | 0.00773677 | 47.6574 | 2628.31 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 6095.244 | 4880.189 | 0.368214 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6028.35 | 5519.49 | 0.368214 | 25.09 | 16.38 | 0.00855451 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 7.0488 | 24.00 | 0.00823882 | 42.5198 | 4159.80 | 0.00 | 6094.21 | 4768.01 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 9688.878 | 9688.878 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9688.88 | 9688.88 | 0.368214 | 17.31 | 12.27 | 0.00720431 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 7.0488 | 21.10 | 0.00773673 | 47.6572 | 2627.87 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 6441.001 | 5157.021 | 0.389101 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6368.25 | 5846.69 | 0.389101 | 25.09 | 16.36 | 0.00853652 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.6704 | 24.00 | 0.00823771 | 42.5142 | 4391.36 | 0.00 | 6439.90 | 5038.48 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 10146.782 | 10146.782 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10146.78 | 10146.78 | 0.389101 | 17.51 | 12.29 | 0.00714614 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.6704 | 21.10 | 0.00764378 | 47.0925 | 2813.10 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 6394.042 | 5119.423 | 0.386264 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6322.31 | 5800.72 | 0.386264 | 25.09 | 16.37 | 0.00854081 | 12.80 | 11.22 | 0.00800000 | 25.26 | 0.01271739 | 19.69 | 6.7194 | 24.00 | 0.00823996 | 42.5257 | 4359.98 | 0.00 | 6392.95 | 5001.75 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 10084.610 | 10084.610 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10084.61 | 10084.61 | 0.386264 | 17.48 | 12.28 | 0.00714244 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 6.7194 | 21.10 | 0.00764373 | 47.0922 | 2812.67 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6169.870 | 4939.939 | 0.372722 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7284 | 1004.8586 | 1.1539 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.372722 | 0.43009300 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6101.12 | 5592.36 | 0.9889 | 0.43009300 | 0.372722 | 25.08 | 16.37 | 0.00854699 | 46976.0 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 417.489 | 5683.63 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 6.9635 | 24.04 | 0.00823485 | 24.00 | 0.00823485 | 42.4999 | 4207.87 | 0.00 | 6168.82 | 4826.39 | 0.41310758 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9787.546 | 9787.546 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.372722 | 0.43009300 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 9787.55 | 9787.55 | 1.0000 | 0.43009300 | 0.372722 | 17.35 | 12.27 | 0.00718365 | 35634.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9787.55 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 6.9635 | 21.10 | 0.00770760 | 21.10 | 0.00770760 | 47.4800 | 3093.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5628.996 | 4506.885 | 0.340048 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8062 | 1004.8586 | 1.1539 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.340048 | 0.39238941 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5570.53 | 5073.73 | 0.9896 | 0.39238941 | 0.340048 | 25.08 | 16.41 | 0.00858884 | 47085.6 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 380.890 | 5189.64 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 7.6326 | 24.04 | 0.00824768 | 24.00 | 0.00824768 | 42.5652 | 3848.12 | 0.00 | 5628.04 | 4403.29 | 0.37689300 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9071.427 | 9071.427 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.340048 | 0.39238941 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 9071.43 | 9071.43 | 1.0000 | 0.39238941 | 0.340048 | 16.99 | 12.12 | 0.00718478 | 35271.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9071.43 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 7.6326 | 21.10 | 0.00776333 | 21.10 | 0.00776333 | 47.8185 | 2953.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6748.828 | 5403.484 | 0.407697 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7859 | 1004.8586 | 1.1539 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.407697 | 0.47045133 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | Sensible | 6703.00 | 6106.73 | 0.9932 | 0.47045133 | 0.407697 | 24.84 | 16.31 | 0.00857789 | 46812.2 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 456.664 | 6246.33 | 23.28 | 0.01271395 | 19.08 | 0.03810604 | 9.3467 | 23.96 | 0.00815145 | 23.90 | 0.00811208 | 42.1255 | 4320.30 | 0.00 | 6747.68 | 5279.28 | 0.45187206 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11312.076 | 11312.076 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.407697 | 0.47045133 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 11312.08 | 11312.08 | 1.0000 | 0.47045133 | 0.407697 | 16.07 | 11.61 | 0.00704888 | 33988.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11312.08 | -32.70 | 0.00018338 | -32.70 | 0.03810604 | 9.3467 | 21.10 | 0.00775674 | 21.10 | 0.00775674 | 47.7789 | 3702.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4971.399 | 3980.377 | 0.300322 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9829 | 1004.8586 | 1.1539 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.300322 | 0.34654926 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4928.07 | 4424.89 | 0.9913 | 0.34654926 | 0.300322 | 25.08 | 16.49 | 0.00868390 | 47328.7 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 336.393 | 4591.67 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 8.6422 | 24.03 | 0.00830234 | 24.00 | 0.00830234 | 42.8438 | 3407.87 | 0.00 | 4970.55 | 3888.88 | 0.33286318 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8200.824 | 8200.824 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.300322 | 0.34654926 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8200.82 | 8200.82 | 1.0000 | 0.34654926 | 0.300322 | 16.45 | 11.83 | 0.00710759 | 34522.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8200.82 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 8.6422 | 21.10 | 0.00776261 | 21.10 | 0.00776261 | 47.8142 | 2943.80 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4449.351 | 3562.397 | 0.268785 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.0331 | 1004.8586 | 1.1539 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.268785 | 0.31015806 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4412.69 | 3946.24 | 0.9918 | 0.31015806 | 0.268785 | 25.08 | 16.51 | 0.00871090 | 47398.0 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 301.069 | 4111.62 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 9.6562 | 24.01 | 0.00828267 | 24.00 | 0.00828267 | 42.7433 | 3059.90 | 0.00 | 4448.59 | 3480.51 | 0.29790916 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7509.627 | 7509.627 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.268785 | 0.31015806 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7509.63 | 7509.63 | 1.0000 | 0.31015806 | 0.268785 | 15.90 | 11.59 | 0.00709508 | 33935.9 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7509.63 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 9.6562 | 21.10 | 0.00783383 | 21.10 | 0.00783383 | 48.2464 | 1946.05 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4437.480 | 3552.892 | 0.268068 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.0369 | 1004.8586 | 1.1539 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.268068 | 0.30933055 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4401.07 | 3934.66 | 0.9918 | 0.30933055 | 0.268068 | 25.08 | 16.51 | 0.00871293 | 47403.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 300.265 | 4100.80 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 9.6821 | 24.01 | 0.00828365 | 24.00 | 0.00828365 | 42.7483 | 3051.93 | 0.00 | 4436.73 | 3471.22 | 0.29711433 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7493.911 | 7493.911 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.268068 | 0.30933055 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7493.91 | 7493.91 | 1.0000 | 0.30933055 | 0.268068 | 15.89 | 11.58 | 0.00709309 | 33916.7 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7493.91 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 9.6821 | 21.10 | 0.00783381 | 21.10 | 0.00783381 | 48.2463 | 1945.79 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5058.525 | 4050.135 | 0.305585 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9044 | 1004.8586 | 1.1539 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.305585 | 0.35262270 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5010.73 | 4527.70 | 0.9906 | 0.35262270 | 0.305585 | 25.09 | 16.45 | 0.00864166 | 47222.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 342.289 | 4668.45 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 8.4934 | 24.03 | 0.00826336 | 24.00 | 0.00826336 | 42.6451 | 3466.39 | 0.00 | 5057.66 | 3957.04 | 0.33869676 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8316.158 | 8316.158 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.305585 | 0.35262270 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8316.16 | 8316.16 | 1.0000 | 0.35262270 | 0.305585 | 16.53 | 11.84 | 0.00708881 | 34556.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8316.16 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 8.4934 | 21.10 | 0.00772976 | 21.10 | 0.00772976 | 47.6140 | 2088.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5089.053 | 4074.577 | 0.307430 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8975 | 1004.8586 | 1.1539 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.307430 | 0.35475079 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5040.62 | 4557.25 | 0.9905 | 0.35475079 | 0.307430 | 25.08 | 16.45 | 0.00863793 | 47212.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 344.354 | 4696.27 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 8.4424 | 24.03 | 0.00826176 | 24.00 | 0.00826176 | 42.6370 | 3486.67 | 0.00 | 5088.19 | 3980.92 | 0.34074082 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8356.575 | 8356.575 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.307430 | 0.35475079 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8356.57 | 8356.57 | 1.0000 | 0.35475079 | 0.307430 | 16.56 | 11.86 | 0.00709407 | 34598.0 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8356.57 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 8.4424 | 21.10 | 0.00773130 | 21.10 | 0.00773130 | 47.6234 | 2099.54 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 15389.858 | 12321.971 | 0.929701 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.5839 | 1004.8586 | 1.1539 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.929701 | 1.07280545 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 15196.94 | 14096.54 | 0.9875 | 1.07280545 | 0.929701 | 25.08 | 16.30 | 0.00846925 | 46774.6 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 1041.366 | 14155.57 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 5.5834 | 24.06 | 0.00821803 | 24.00 | 0.00821803 | 42.4142 | 20909.14 | 0.00 | 15387.24 | 12038.73 | 1.03043774 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 23614.096 | 23614.096 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.929701 | 1.07280545 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 23614.10 | 23614.10 | 1.0000 | 1.07280545 | 0.929701 | 18.09 | 12.48 | 0.00709712 | 36170.7 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23614.10 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 5.5834 | 21.10 | 0.00750597 | 21.10 | 0.00750597 | 46.2542 | 9982.96 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14507.373 | 11615.404 | 0.876390 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.6211 | 1004.8586 | 1.1539 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.876390 | 1.01128865 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 14330.60 | 13252.03 | 0.9878 | 1.01128865 | 0.876390 | 25.08 | 16.32 | 0.00848925 | 46825.2 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 981.652 | 13348.95 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 5.9231 | 24.05 | 0.00822304 | 24.00 | 0.00822304 | 42.4396 | 19724.57 | 0.00 | 14504.90 | 11348.41 | 0.97135039 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 22445.399 | 22445.399 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.876390 | 1.01128865 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 22445.40 | 22445.40 | 1.0000 | 1.01128865 | 0.876390 | 17.91 | 12.47 | 0.00716300 | 36151.9 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22445.40 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 5.9231 | 21.10 | 0.00760244 | 21.10 | 0.00760244 | 46.8406 | 9319.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13227.626 | 10590.768 | 0.799081 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7465 | 1004.8586 | 1.1539 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.799081 | 0.92207929 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 13082.37 | 11973.66 | 0.9890 | 0.92207929 | 0.799081 | 25.08 | 16.38 | 0.00855670 | 46999.5 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 895.057 | 12187.31 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 6.4961 | 24.05 | 0.00826764 | 24.00 | 0.00826764 | 42.6671 | 18016.21 | 0.00 | 13225.37 | 10347.33 | 0.88566413 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20751.334 | 20751.334 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.799081 | 0.92207929 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 20751.33 | 20751.33 | 1.0000 | 0.92207929 | 0.799081 | 17.60 | 12.21 | 0.00702831 | 35496.5 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20751.33 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 6.4961 | 21.10 | 0.00750385 | 21.10 | 0.00750385 | 46.2413 | 9937.63 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12373.646 | 9907.024 | 0.747492 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8015 | 1004.8586 | 1.1539 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.747492 | 0.86254952 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12244.30 | 11156.44 | 0.9895 | 0.86254952 | 0.747492 | 25.08 | 16.40 | 0.00858629 | 47076.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 837.272 | 11407.03 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 6.9444 | 24.05 | 0.00827800 | 24.00 | 0.00827800 | 42.7199 | 16876.65 | 0.00 | 12371.54 | 9679.30 | 0.82848534 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 19620.424 | 19620.424 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.747492 | 0.86254952 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 19620.42 | 19620.42 | 1.0000 | 0.86254952 | 0.747492 | 17.36 | 12.17 | 0.00708554 | 35396.2 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19620.42 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 6.9444 | 21.10 | 0.00760062 | 21.10 | 0.00760062 | 46.8295 | 9274.29 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11072.120 | 8864.951 | 0.668867 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8152 | 1004.8586 | 1.1539 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.668867 | 0.77182198 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 10958.10 | 9973.56 | 0.9897 | 0.77182198 | 0.668867 | 25.08 | 16.41 | 0.00859368 | 47098.6 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 749.203 | 10208.90 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 7.7608 | 24.04 | 0.00824672 | 24.00 | 0.00824672 | 42.5601 | 15144.16 | 0.00 | 11070.24 | 8661.18 | 0.74134084 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17896.902 | 17896.902 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.668867 | 0.77182198 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17896.90 | 17896.90 | 1.0000 | 0.77182198 | 0.668867 | 16.92 | 11.99 | 0.00708048 | 34936.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17896.90 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 7.7608 | 21.10 | 0.00766078 | 21.10 | 0.00766078 | 47.1942 | 5168.71 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11037.243 | 8837.027 | 0.666760 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8192 | 1004.8586 | 1.1539 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.666760 | 0.76939077 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 10924.00 | 9939.30 | 0.9897 | 0.76939077 | 0.666760 | 25.08 | 16.41 | 0.00859582 | 47104.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 746.843 | 10177.16 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 7.7853 | 24.04 | 0.00824786 | 24.00 | 0.00824786 | 42.5659 | 15097.33 | 0.00 | 11035.36 | 8633.90 | 0.73900565 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17850.728 | 17850.728 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.666760 | 0.76939077 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17850.73 | 17850.73 | 1.0000 | 0.76939077 | 0.666760 | 16.91 | 11.99 | 0.00707858 | 34918.5 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17850.73 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 7.7853 | 21.10 | 0.00766071 | 21.10 | 0.00766071 | 47.1938 | 5167.60 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12076.036 | 9668.742 | 0.729513 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7367 | 1004.8586 | 1.1539 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.729513 | 0.84180358 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11942.57 | 10939.39 | 0.9889 | 0.84180358 | 0.729513 | 25.08 | 16.37 | 0.00855144 | 46989.2 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 817.134 | 11125.44 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 7.1156 | 24.04 | 0.00823230 | 24.00 | 0.00823230 | 42.4867 | 16481.45 | 0.00 | 12073.98 | 9446.49 | 0.80855870 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 19226.278 | 19226.278 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.729513 | 0.84180358 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 19226.28 | 19226.28 | 1.0000 | 0.84180358 | 0.729513 | 17.27 | 12.02 | 0.00696859 | 35006.4 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19226.28 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 7.1156 | 21.10 | 0.00748838 | 21.10 | 0.00748838 | 46.1458 | 5819.94 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12038.247 | 9638.486 | 0.727230 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7405 | 1004.8586 | 1.1539 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.727230 | 0.83916935 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11905.64 | 10902.14 | 0.9890 | 0.83916935 | 0.727230 | 25.08 | 16.38 | 0.00855351 | 46994.6 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 814.577 | 11091.07 | 25.26 | 0.01271739 | 19.69 | 0.05190911 | 7.1379 | 24.04 | 0.00823345 | 24.00 | 0.00823345 | 42.4926 | 16431.18 | 0.00 | 12036.20 | 9416.93 | 0.80602850 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 19176.247 | 19176.247 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.727230 | 0.83916935 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 19176.25 | 19176.25 | 1.0000 | 0.83916935 | 0.727230 | 17.26 | 12.02 | 0.00696687 | 34989.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19176.25 | -32.70 | 0.00018338 | -32.70 | 0.05190911 | 7.1379 | 21.10 | 0.00748829 | 21.10 | 0.00748829 | 46.1452 | 5818.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8364.087 | 6696.751 | 0.505275 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.5899 | 1004.8586 | 1.1539 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.505275 | 0.58304883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 8259.67 | 7657.74 | 0.9875 | 0.58304883 | 0.505275 | 25.08 | 16.31 | 0.00847250 | 46782.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 565.962 | 7693.71 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 5.1367 | 24.06 | 0.00824264 | 24.00 | 0.00824264 | 42.5399 | 5675.50 | 0.00 | 8362.66 | 6542.82 | 0.56002281 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12693.252 | 12693.252 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.505275 | 0.58304883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12693.25 | 12693.25 | 1.0000 | 0.58304883 | 0.505275 | 18.33 | 12.69 | 0.00721496 | 36713.6 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12693.25 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 5.1367 | 21.10 | 0.00759571 | 21.10 | 0.00759571 | 46.8018 | 4081.33 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8103.928 | 6488.452 | 0.489558 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.6009 | 1004.8586 | 1.1539 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.489558 | 0.56491347 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 8003.66 | 7413.66 | 0.9876 | 0.56491347 | 0.489558 | 25.08 | 16.31 | 0.00847841 | 46798.2 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 548.358 | 7455.31 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 5.3016 | 24.06 | 0.00824109 | 24.00 | 0.00824109 | 42.5319 | 5501.82 | 0.00 | 8102.55 | 6339.31 | 0.54260366 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12348.626 | 12348.626 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.489558 | 0.56491347 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12348.63 | 12348.63 | 1.0000 | 0.56491347 | 0.489558 | 18.25 | 12.69 | 0.00725973 | 36737.1 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12348.63 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 5.3016 | 21.10 | 0.00765590 | 21.10 | 0.00765590 | 47.1672 | 3896.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6805.708 | 5449.026 | 0.411133 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7998 | 1004.8586 | 1.1539 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.411133 | 0.47441635 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6734.60 | 6137.21 | 0.9896 | 0.47441635 | 0.411133 | 25.08 | 16.40 | 0.00858538 | 47076.9 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 460.513 | 6274.09 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 6.3129 | 24.06 | 0.00830696 | 24.00 | 0.00830696 | 42.8677 | 4635.45 | 0.00 | 6804.55 | 5323.77 | 0.45568049 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10629.932 | 10629.932 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.411133 | 0.47441635 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10629.93 | 10629.93 | 1.0000 | 0.47441635 | 0.411133 | 17.70 | 12.35 | 0.00712628 | 35844.6 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10629.93 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 6.3129 | 21.10 | 0.00759412 | 21.10 | 0.00759412 | 46.7921 | 4064.44 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6547.485 | 5242.278 | 0.395534 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8212 | 1004.8586 | 1.1539 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.395534 | 0.45641601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6480.39 | 5895.23 | 0.9898 | 0.45641601 | 0.395534 | 25.08 | 16.41 | 0.00859691 | 47105.9 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 443.040 | 6037.35 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 6.5619 | 24.05 | 0.00830754 | 24.00 | 0.00830754 | 42.8706 | 4461.80 | 0.00 | 6546.37 | 5121.78 | 0.43839102 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10287.905 | 10287.905 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.395534 | 0.45641601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10287.90 | 10287.90 | 1.0000 | 0.45641601 | 0.395534 | 17.57 | 12.33 | 0.00716423 | 35804.7 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10287.90 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 6.5619 | 21.10 | 0.00765448 | 21.10 | 0.00765448 | 47.1586 | 3879.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6142.198 | 4917.783 | 0.371050 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7339 | 1004.8586 | 1.1539 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.371050 | 0.42816400 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6074.28 | 5565.41 | 0.9889 | 0.42816400 | 0.371050 | 25.09 | 16.37 | 0.00854993 | 46988.3 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 415.616 | 5658.66 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 6.9949 | 24.05 | 0.00823649 | 24.00 | 0.00823649 | 42.5080 | 4191.11 | 0.00 | 6141.15 | 4804.74 | 0.41125476 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9751.041 | 9751.041 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.371050 | 0.42816400 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9751.04 | 9751.04 | 1.0000 | 0.42816400 | 0.371050 | 17.34 | 12.28 | 0.00720842 | 35680.1 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9751.04 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 6.9949 | 21.10 | 0.00773677 | 21.10 | 0.00773677 | 47.6574 | 2628.31 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6095.244 | 4880.189 | 0.368214 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7424 | 1004.8586 | 1.1539 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.368214 | 0.42489094 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6028.35 | 5519.49 | 0.9890 | 0.42489094 | 0.368214 | 25.09 | 16.38 | 0.00855451 | 47000.3 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 412.439 | 5615.91 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 7.0488 | 24.05 | 0.00823882 | 24.00 | 0.00823882 | 42.5198 | 4159.80 | 0.00 | 6094.21 | 4768.01 | 0.40811096 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9688.878 | 9688.878 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.368214 | 0.42489094 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9688.88 | 9688.88 | 1.0000 | 0.42489094 | 0.368214 | 17.31 | 12.27 | 0.00720431 | 35640.1 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9688.88 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 7.0488 | 21.10 | 0.00773673 | 21.10 | 0.00773673 | 47.6572 | 2627.87 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6441.001 | 5157.021 | 0.389101 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7090 | 1004.8586 | 1.1539 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.389101 | 0.44899315 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6368.25 | 5846.69 | 0.9887 | 0.44899315 | 0.389101 | 25.09 | 16.36 | 0.00853652 | 46953.9 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 435.835 | 5932.41 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 6.6704 | 24.05 | 0.00823771 | 24.00 | 0.00823771 | 42.5142 | 4391.36 | 0.00 | 6439.90 | 5038.48 | 0.43126131 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10146.782 | 10146.782 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.389101 | 0.44899315 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10146.78 | 10146.78 | 1.0000 | 0.44899315 | 0.389101 | 17.51 | 12.29 | 0.00714614 | 35699.7 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10146.78 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 6.6704 | 21.10 | 0.00764378 | 21.10 | 0.00764378 | 47.0925 | 2813.10 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6394.042 | 5119.423 | 0.386264 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7169 | 1004.8586 | 1.1539 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.386264 | 0.44571969 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6322.31 | 5800.72 | 0.9888 | 0.44571969 | 0.386264 | 25.09 | 16.37 | 0.00854081 | 46965.1 | 12.80 | 11.22 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 432.657 | 5889.66 | 25.26 | 0.01271739 | 19.69 | 0.02595455 | 6.7194 | 24.05 | 0.00823996 | 24.00 | 0.00823996 | 42.5257 | 4359.98 | 0.00 | 6392.95 | 5001.75 | 0.42811713 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.25 | 14.42 | 0.00991057 | 40389.7 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10084.610 | 10084.610 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.386264 | 0.44571969 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10084.61 | 10084.61 | 1.0000 | 0.44571969 | 0.386264 | 17.48 | 12.28 | 0.00714244 | 35663.5 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10084.61 | -32.70 | 0.00018338 | -32.70 | 0.02595455 | 6.7194 | 21.10 | 0.00764373 | 21.10 | 0.00764373 | 47.0922 | 2812.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 4012.33 | 4628.00 | 3112.17 |
| G NW APARTMENT | 5871.17 | 6943.67 | 4798.50 |
| OFFICE | 1343.00 | 1141.17 | 843.67 |
| G NE APARTMENT | 5876.50 | 6946.67 | 4820.17 |
| G N1 APARTMENT | 5621.83 | 6860.83 | 4630.17 |
| G N2 APARTMENT | 5626.33 | 6856.50 | 4635.17 |
| G S1 APARTMENT | 3759.50 | 4496.67 | 2868.83 |
| G S2 APARTMENT | 3914.83 | 4425.83 | 2923.67 |
| M SW APARTMENT | 3510.67 | 4175.17 | 2446.50 |
| M NW APARTMENT | 5394.67 | 6224.50 | 3952.33 |
| M SE APARTMENT | 3504.83 | 4189.33 | 2454.17 |
| M NE APARTMENT | 5417.50 | 6229.00 | 3933.50 |
| M N1 APARTMENT | 4865.00 | 6230.00 | 3618.67 |
| M N2 APARTMENT | 4867.67 | 6227.33 | 3618.17 |
| M S1 APARTMENT | 3016.50 | 4108.67 | 2014.50 |
| M S2 APARTMENT | 3016.33 | 4110.83 | 2015.67 |
| T SW APARTMENT | 3998.33 | 4811.83 | 3141.83 |
| T NW APARTMENT | 5929.00 | 6957.50 | 4694.83 |
| T SE APARTMENT | 4002.67 | 4848.67 | 3173.67 |
| T NE APARTMENT | 5990.50 | 6934.83 | 4684.17 |
| T N1 APARTMENT | 5742.50 | 6902.50 | 4549.83 |
| T N2 APARTMENT | 5742.83 | 6903.33 | 4550.67 |
| T S1 APARTMENT | 3767.50 | 4700.83 | 2930.50 |
| T S2 APARTMENT | 3769.17 | 4703.67 | 2934.17 |
| T CORRIDOR | 7307.50 | 8700.17 | 7265.00 |
| G CORRIDOR | 6908.67 | 7515.67 | 5933.17 |
| M CORRIDOR | 5946.50 | 8728.17 | 5941.17 |
| Facility | 8755.17 | 8760.00 | 8755.17 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.091 | 0.000 | 0.039 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.098 | 0.000 | 0.051 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.517 | 0.113 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.098 | 0.000 | 0.051 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.059 | 0.000 | 0.051 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.059 | 0.000 | 0.051 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.055 | 0.000 | 0.039 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.055 | 0.000 | 0.039 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.131 | 0.000 | 0.046 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.141 | 0.000 | 0.062 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.131 | 0.000 | 0.046 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.141 | 0.000 | 0.062 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.085 | 0.000 | 0.062 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.085 | 0.000 | 0.062 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.353 | 0.079 | 0.000 | 0.046 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.353 | 0.079 | 0.000 | 0.046 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.174 | 0.000 | 0.053 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.187 | 0.000 | 0.072 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.174 | 0.000 | 0.053 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.187 | 0.000 | 0.073 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.113 | 0.000 | 0.072 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.113 | 0.000 | 0.072 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.105 | 0.000 | 0.053 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.352 | 0.105 | 0.000 | 0.053 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.495 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.21 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 121418.98 | 939921.76 | 228416.51 | 1168338.26 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 2615.00 |
| G NW APARTMENT | 818502.78 | 117642.23 | 936145.01 | 228416.51 | 1164561.52 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 228416.51 | 1430128.48 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 117863.87 | 936366.65 | 228416.51 | 1164783.16 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 0.00 |
| G N1 APARTMENT | 818502.78 | 117699.92 | 936202.69 | 137775.04 | 1073977.73 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 0.00 |
| G N2 APARTMENT | 818502.78 | 117716.06 | 936218.84 | 137775.04 | 1073993.88 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 0.00 |
| G S1 APARTMENT | 818502.78 | 121601.59 | 940104.37 | 137775.04 | 1077879.41 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 121644.31 | 940147.09 | 137775.04 | 1077922.12 | 818502.78 | 0.00 | 7477.00 | 1283.00 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 147190.71 | 1784196.27 | 328253.04 | 2112449.31 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 143050.14 | 1780055.70 | 328253.04 | 2108308.74 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 0.00 |
| M SE APARTMENT | 1637005.55 | 147211.75 | 1784217.30 | 328253.04 | 2112470.34 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 143176.28 | 1780181.84 | 328253.04 | 2108434.88 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 142964.68 | 1779970.23 | 197993.90 | 1977964.14 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 142979.05 | 1779984.61 | 197993.90 | 1977978.51 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 147237.34 | 1784242.89 | 197993.90 | 1982236.80 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 147238.48 | 1784244.04 | 197993.90 | 1982237.94 | 1637005.55 | 0.00 | 7456.33 | 1303.67 | 2615.00 |
| T SW APARTMENT | 818502.78 | 171494.15 | 989996.92 | 434213.79 | 1424210.71 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 2615.00 |
| T NW APARTMENT | 818502.78 | 165914.70 | 984417.48 | 434213.79 | 1418631.27 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 0.00 |
| T SE APARTMENT | 818502.78 | 171859.07 | 990361.84 | 434213.79 | 1424575.63 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 2615.00 |
| T NE APARTMENT | 818502.78 | 166563.34 | 985066.12 | 434213.79 | 1419279.91 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 0.00 |
| T N1 APARTMENT | 818502.78 | 166025.59 | 984528.37 | 261906.74 | 1246435.10 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 0.00 |
| T N2 APARTMENT | 818502.78 | 166094.41 | 984597.18 | 261906.74 | 1246503.92 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 0.00 |
| T S1 APARTMENT | 818502.78 | 171783.99 | 990286.77 | 261906.74 | 1252193.50 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 171805.40 | 990308.18 | 261906.74 | 1252214.91 | 818502.78 | 0.00 | 7475.33 | 1284.67 | 2615.00 |
| Total Facility | 39671342.50 | 4509224.48 | 44180566.98 | 8459223.86 | 52639790.84 | 39671342.50 | 0.00 | 8760.00 | 1307.00 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0028 | 0.0288 | 0.0067 | 0.0355 | 0.0260 | 0.00 | 5473.83 | 671.17 |
| G NW APARTMENT | 0.0260 | 0.0037 | 0.0297 | 0.0072 | 0.0369 | 0.0260 | 0.00 | 7477.00 | 1283.00 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0083 | 0.0464 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0037 | 0.0297 | 0.0072 | 0.0369 | 0.0260 | 0.00 | 7477.00 | 1283.00 |
| G N1 APARTMENT | 0.0260 | 0.0037 | 0.0297 | 0.0044 | 0.0341 | 0.0260 | 0.00 | 7477.00 | 1283.00 |
| G N2 APARTMENT | 0.0260 | 0.0037 | 0.0297 | 0.0044 | 0.0341 | 0.0260 | 0.00 | 7477.00 | 1283.00 |
| G S1 APARTMENT | 0.0260 | 0.0028 | 0.0288 | 0.0041 | 0.0328 | 0.0260 | 0.00 | 5473.83 | 671.17 |
| G S2 APARTMENT | 0.0260 | 0.0028 | 0.0288 | 0.0041 | 0.0328 | 0.0260 | 0.00 | 5473.83 | 671.17 |
| M SW APARTMENT | 0.0519 | 0.0033 | 0.0552 | 0.0097 | 0.0649 | 0.0519 | 0.00 | 5464.83 | 680.17 |
| M NW APARTMENT | 0.0519 | 0.0045 | 0.0564 | 0.0104 | 0.0669 | 0.0519 | 0.00 | 7456.33 | 1303.67 |
| M SE APARTMENT | 0.0519 | 0.0033 | 0.0552 | 0.0097 | 0.0649 | 0.0519 | 0.00 | 5464.83 | 680.17 |
| M NE APARTMENT | 0.0519 | 0.0045 | 0.0564 | 0.0104 | 0.0669 | 0.0519 | 0.00 | 7456.33 | 1303.67 |
| M N1 APARTMENT | 0.0519 | 0.0045 | 0.0564 | 0.0063 | 0.0627 | 0.0519 | 0.00 | 7456.33 | 1303.67 |
| M N2 APARTMENT | 0.0519 | 0.0045 | 0.0564 | 0.0063 | 0.0627 | 0.0519 | 0.00 | 7456.33 | 1303.67 |
| M S1 APARTMENT | 0.0519 | 0.0033 | 0.0552 | 0.0058 | 0.0611 | 0.0519 | 0.00 | 5464.83 | 680.17 |
| M S2 APARTMENT | 0.0519 | 0.0033 | 0.0552 | 0.0058 | 0.0611 | 0.0519 | 0.00 | 5464.83 | 680.17 |
| T SW APARTMENT | 0.0260 | 0.0038 | 0.0298 | 0.0128 | 0.0426 | 0.0260 | 0.00 | 5474.67 | 670.33 |
| T NW APARTMENT | 0.0260 | 0.0053 | 0.0312 | 0.0138 | 0.0450 | 0.0260 | 0.00 | 7475.33 | 1284.67 |
| T SE APARTMENT | 0.0260 | 0.0038 | 0.0298 | 0.0128 | 0.0426 | 0.0260 | 0.00 | 5474.67 | 670.33 |
| T NE APARTMENT | 0.0260 | 0.0053 | 0.0312 | 0.0138 | 0.0450 | 0.0260 | 0.00 | 7475.33 | 1284.67 |
| T N1 APARTMENT | 0.0260 | 0.0053 | 0.0312 | 0.0083 | 0.0395 | 0.0260 | 0.00 | 7475.33 | 1284.67 |
| T N2 APARTMENT | 0.0260 | 0.0053 | 0.0312 | 0.0083 | 0.0395 | 0.0260 | 0.00 | 7475.33 | 1284.67 |
| T S1 APARTMENT | 0.0260 | 0.0038 | 0.0298 | 0.0077 | 0.0375 | 0.0260 | 0.00 | 5474.67 | 670.33 |
| T S2 APARTMENT | 0.0260 | 0.0038 | 0.0298 | 0.0077 | 0.0375 | 0.0260 | 0.00 | 5474.67 | 670.33 |
| Total Facility | 1.2580 | 0.1228 | 1.3808 | 0.2604 | 1.6412 | 1.2580 | 0.00 | 8760.00 | 1307.00 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 121418.98 | 121418.98 | 818502.78 | 8042.86 | 39.06 | 678.08 | 611.83 |
| SPLIT GNW | 0.00 | 117642.23 | 117642.23 | 818502.78 | 8118.17 | 41.50 | 600.33 | 0.00 |
| SPLIT OFFICE | 1600130.65 | 0.00 | 1600130.65 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 117863.87 | 117863.87 | 818502.78 | 8113.38 | 42.37 | 604.25 | 0.00 |
| SPLIT GN1 | 0.00 | 117699.92 | 117699.92 | 818502.78 | 8117.38 | 42.35 | 600.28 | 0.00 |
| SPLIT GN2 | 0.00 | 117716.06 | 117716.06 | 818502.78 | 8117.38 | 42.24 | 600.39 | 0.00 |
| SPLIT GS1 | 0.00 | 121601.59 | 121601.59 | 818502.78 | 8039.50 | 38.17 | 682.33 | 611.83 |
| SPLIT GS2 | 0.00 | 121644.31 | 121644.31 | 818502.78 | 8039.50 | 37.50 | 683.00 | 611.83 |
| SPLIT MSW | 0.00 | 147190.71 | 147190.71 | 1637005.55 | 8729.50 | 6.50 | 24.00 | 623.50 |
| SPLIT MNW | 0.00 | 143050.14 | 143050.14 | 1637005.55 | 8733.67 | 4.67 | 21.67 | 0.00 |
| SPLIT MSE | 0.00 | 147211.75 | 147211.75 | 1637005.55 | 8729.00 | 7.00 | 24.00 | 623.50 |
| SPLIT MNE | 0.00 | 143176.28 | 143176.28 | 1637005.55 | 8733.00 | 5.50 | 21.50 | 0.00 |
| SPLIT MN1 | 0.00 | 142964.68 | 142964.68 | 1637005.55 | 8733.17 | 5.58 | 21.25 | 0.00 |
| SPLIT MN2 | 0.00 | 142979.05 | 142979.05 | 1637005.55 | 8733.17 | 5.58 | 21.25 | 0.00 |
| SPLIT MS1 | 0.00 | 147237.34 | 147237.34 | 1637005.55 | 8728.83 | 6.83 | 24.33 | 623.50 |
| SPLIT MS2 | 0.00 | 147238.48 | 147238.48 | 1637005.55 | 8728.83 | 6.83 | 24.33 | 623.50 |
| SPLIT TSW | 0.00 | 171494.15 | 171494.15 | 818502.78 | 7693.50 | 14.17 | 1052.33 | 614.33 |
| SPLIT TNW | 0.00 | 165914.70 | 165914.70 | 818502.78 | 7703.75 | 20.46 | 1035.79 | 0.00 |
| SPLIT TSE | 0.00 | 171859.07 | 171859.07 | 818502.78 | 7691.83 | 13.33 | 1054.83 | 614.33 |
| SPLIT TNE | 0.00 | 166563.34 | 166563.34 | 818502.78 | 7701.67 | 20.33 | 1038.00 | 0.00 |
| SPLIT TN1 | 0.00 | 166025.59 | 166025.59 | 818502.78 | 7702.67 | 20.33 | 1037.00 | 0.00 |
| SPLIT TN2 | 0.00 | 166094.41 | 166094.41 | 818502.78 | 7702.67 | 20.17 | 1037.17 | 0.00 |
| SPLIT TS1 | 0.00 | 171783.99 | 171783.99 | 818502.78 | 7692.50 | 13.94 | 1053.56 | 614.33 |
| SPLIT TS2 | 0.00 | 171805.40 | 171805.40 | 818502.78 | 7692.33 | 13.50 | 1054.17 | 614.33 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0028 | 0.0028 | 0.0260 | 5788.67 | 22.50 | 333.83 |
| SPLIT GNW | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 8118.17 | 41.50 | 600.33 |
| SPLIT OFFICE | 0.0507 | 0.0000 | 0.0507 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 8113.38 | 42.37 | 604.25 |
| SPLIT GN1 | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 8117.38 | 42.35 | 600.28 |
| SPLIT GN2 | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 8117.38 | 42.24 | 600.39 |
| SPLIT GS1 | 0.0000 | 0.0028 | 0.0028 | 0.0260 | 5786.83 | 23.00 | 335.17 |
| SPLIT GS2 | 0.0000 | 0.0028 | 0.0028 | 0.0260 | 5786.83 | 22.83 | 335.33 |
| SPLIT MSW | 0.0000 | 0.0033 | 0.0033 | 0.0519 | 6134.83 | 3.17 | 7.00 |
| SPLIT MNW | 0.0000 | 0.0045 | 0.0045 | 0.0519 | 8733.67 | 4.67 | 21.67 |
| SPLIT MSE | 0.0000 | 0.0033 | 0.0033 | 0.0519 | 6134.67 | 3.33 | 7.00 |
| SPLIT MNE | 0.0000 | 0.0045 | 0.0045 | 0.0519 | 8733.00 | 5.50 | 21.50 |
| SPLIT MN1 | 0.0000 | 0.0045 | 0.0045 | 0.0519 | 8733.17 | 5.58 | 21.25 |
| SPLIT MN2 | 0.0000 | 0.0045 | 0.0045 | 0.0519 | 8733.17 | 5.58 | 21.25 |
| SPLIT MS1 | 0.0000 | 0.0033 | 0.0033 | 0.0519 | 6134.33 | 3.33 | 7.33 |
| SPLIT MS2 | 0.0000 | 0.0033 | 0.0033 | 0.0519 | 6134.33 | 3.33 | 7.33 |
| SPLIT TSW | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5605.50 | 9.50 | 530.00 |
| SPLIT TNW | 0.0000 | 0.0053 | 0.0053 | 0.0260 | 7703.75 | 20.46 | 1035.79 |
| SPLIT TSE | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5604.83 | 9.67 | 530.50 |
| SPLIT TNE | 0.0000 | 0.0053 | 0.0053 | 0.0260 | 7701.67 | 20.33 | 1038.00 |
| SPLIT TN1 | 0.0000 | 0.0053 | 0.0053 | 0.0260 | 7702.67 | 20.33 | 1037.00 |
| SPLIT TN2 | 0.0000 | 0.0053 | 0.0053 | 0.0260 | 7702.67 | 20.17 | 1037.17 |
| SPLIT TS1 | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5605.00 | 9.67 | 530.33 |
| SPLIT TS2 | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5605.00 | 9.67 | 530.33 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 0.00 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0000 | 0.0507 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 103.95 | 1697.09 | 09-MAY-14:20 | 9280.92 | 29-JUN-16:10 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| ElectricityPurchased:Plant | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| Cogeneration:ElectricityPurchased | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| General:Cogeneration:ElectricityPurchased | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| ElectricityNet:Plant | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| Cogeneration:ElectricityNet | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| General:Cogeneration:ElectricityNet | 1306.36 | 16800.11 | 10-JUL-04:50 | 90409.55 | 29-JUN-16:30 |
| Electricity:HVAC | 173.50 | 1697.09 | 09-MAY-14:20 | 38096.43 | 29-JUN-16:00 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 103.95 | 1697.09 | 09-MAY-14:20 | 9280.92 | 29-JUN-16:10 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 69.55 | 0.00 | 01-JAN-00:10 | 28981.74 | 29-JUN-16:00 |
| General:Cooling:Electricity | 69.55 | 0.00 | 01-JAN-00:10 | 28981.74 | 29-JUN-16:00 |
| ExteriorLights:Electricity | 49.91 | 0.00 | 01-JAN-08:20 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 49.91 | 0.00 | 01-JAN-08:20 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 525.06 | 1950.00 | 01-JAN-00:10 | 50557.77 | 03-FEB-07:40 |
| WaterSystems:Electricity | 525.06 | 1950.00 | 01-JAN-00:10 | 50557.77 | 03-FEB-07:40 |
| Water Heater:WaterSystems:Electricity | 525.06 | 1950.00 | 01-JAN-00:10 | 50557.77 | 03-FEB-07:40 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 901.04 | 0.00 | 11-APR-17:30 | 146802.58 | 04-JAN-08:10 |
| NaturalGas:HVAC | 901.04 | 0.00 | 11-APR-17:30 | 146802.58 | 04-JAN-08:10 |
| Heating:NaturalGas | 901.04 | 0.00 | 11-APR-17:30 | 146802.58 | 04-JAN-08:10 |
| General:Heating:NaturalGas | 901.04 | 0.00 | 11-APR-17:30 | 146802.58 | 04-JAN-08:10 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 1689.68 | 2865.60 | 10-MAY-10:20 | 192179.79 | 04-JAN-06:00 |
| EnergyTransfer:Building | 692.69 | 2815.35 | 01-NOV-11:30 | 74747.19 | 04-JAN-06:00 |
| EnergyTransfer:Zone:G SW APARTMENT | 21.85 | 0.04 | 29-OCT-18:10 | 2539.21 | 09-JAN-08:10 |
| Heating:EnergyTransfer | 338.33 | 0.00 | 11-APR-20:10 | 74747.19 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 12.52 | 0.00 | 27-JAN-13:40 | 2539.21 | 09-JAN-08:10 |
| General:Heating:EnergyTransfer | 338.33 | 0.00 | 11-APR-20:10 | 74747.19 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 12.52 | 0.00 | 27-JAN-13:40 | 2539.21 | 09-JAN-08:10 |
| Cooling:EnergyTransfer | 354.35 | 0.00 | 01-JAN-00:10 | 66141.21 | 30-JUN-15:10 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 9.33 | 0.00 | 01-JAN-00:10 | 2117.13 | 29-JUL-16:10 |
| General:Cooling:EnergyTransfer | 354.35 | 0.00 | 01-JAN-00:10 | 66141.21 | 30-JUN-15:10 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 9.33 | 0.00 | 01-JAN-00:10 | 2117.13 | 29-JUL-16:10 |
| EnergyTransfer:Zone:G NW APARTMENT | 24.18 | 0.05 | 04-OCT-09:10 | 2875.52 | 04-JAN-12:00 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 17.56 | 0.00 | 26-MAR-16:10 | 2875.52 | 04-JAN-12:00 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 17.56 | 0.00 | 26-MAR-16:10 | 2875.52 | 04-JAN-12:00 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 6.62 | 0.00 | 01-JAN-00:10 | 1844.50 | 30-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 6.62 | 0.00 | 01-JAN-00:10 | 1844.50 | 30-JUN-18:00 |
| EnergyTransfer:Zone:OFFICE | 17.82 | 0.01 | 26-AUG-23:50 | 5483.59 | 09-JAN-08:10 |
| Heating:EnergyTransfer:Zone:OFFICE | 8.57 | 0.00 | 02-JAN-11:50 | 5483.59 | 09-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 8.57 | 0.00 | 02-JAN-11:50 | 5483.59 | 09-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 9.25 | 0.00 | 01-JAN-00:10 | 3920.55 | 24-JUL-08:10 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 9.25 | 0.00 | 01-JAN-00:10 | 3920.55 | 24-JUL-08:10 |
| EnergyTransfer:Zone:G NE APARTMENT | 24.02 | 0.07 | 07-MAY-03:10 | 2802.12 | 05-JAN-08:10 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 17.43 | 0.00 | 11-APR-10:10 | 2802.12 | 05-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 17.43 | 0.00 | 11-APR-10:10 | 2802.12 | 05-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.59 | 0.00 | 01-JAN-00:10 | 1435.84 | 29-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.59 | 0.00 | 01-JAN-00:10 | 1435.84 | 29-JUN-18:00 |
| EnergyTransfer:Zone:G N1 APARTMENT | 16.11 | 0.03 | 09-OCT-08:00 | 1828.75 | 05-JAN-08:20 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 9.79 | 0.00 | 28-MAR-15:50 | 1828.75 | 05-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 9.79 | 0.00 | 28-MAR-15:50 | 1828.75 | 05-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 6.32 | 0.00 | 01-JAN-00:10 | 1214.47 | 29-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 6.32 | 0.00 | 01-JAN-00:10 | 1214.47 | 29-JUN-18:00 |
| EnergyTransfer:Zone:G N2 APARTMENT | 16.11 | 0.04 | 02-NOV-03:50 | 1828.69 | 05-JAN-08:20 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 9.79 | 0.00 | 28-MAR-16:00 | 1828.69 | 05-JAN-08:20 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 9.79 | 0.00 | 28-MAR-16:00 | 1828.69 | 05-JAN-08:20 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 6.32 | 0.00 | 01-JAN-00:10 | 1206.35 | 29-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 6.32 | 0.00 | 01-JAN-00:10 | 1206.35 | 29-JUN-18:00 |
| EnergyTransfer:Zone:G S1 APARTMENT | 15.11 | 0.06 | 26-MAR-23:20 | 1629.60 | 01-SEP-15:10 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 5.46 | 0.00 | 02-JAN-12:00 | 1565.92 | 09-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 5.46 | 0.00 | 02-JAN-12:00 | 1565.92 | 09-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 9.66 | 0.00 | 01-JAN-00:10 | 1629.60 | 01-SEP-15:10 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 9.66 | 0.00 | 01-JAN-00:10 | 1629.60 | 01-SEP-15:10 |
| EnergyTransfer:Zone:G S2 APARTMENT | 16.88 | 0.01 | 23-MAR-19:40 | 1755.31 | 09-JAN-08:10 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 6.82 | 0.00 | 13-JAN-13:50 | 1755.31 | 09-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 6.82 | 0.00 | 13-JAN-13:50 | 1755.31 | 09-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 10.07 | 0.00 | 01-JAN-00:10 | 1714.75 | 23-JUL-15:10 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 10.07 | 0.00 | 01-JAN-00:10 | 1714.75 | 23-JUL-15:10 |
| EnergyTransfer:Zone:M SW APARTMENT | 46.02 | 0.05 | 07-NOV-19:30 | 5716.81 | 29-JUL-16:10 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 15.89 | 0.00 | 02-JAN-11:50 | 4913.49 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 15.89 | 0.00 | 02-JAN-11:50 | 4913.49 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 30.13 | 0.00 | 01-JAN-00:10 | 5716.81 | 29-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 30.13 | 0.00 | 01-JAN-00:10 | 5716.81 | 29-JUL-16:10 |
| EnergyTransfer:Zone:M NW APARTMENT | 45.30 | 0.02 | 29-MAR-09:20 | 5593.09 | 04-JAN-12:00 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 23.59 | 0.00 | 08-FEB-13:50 | 5593.09 | 04-JAN-12:00 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 23.59 | 0.00 | 08-FEB-13:50 | 5593.09 | 04-JAN-12:00 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 21.71 | 0.00 | 01-JAN-00:10 | 5229.12 | 30-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 21.71 | 0.00 | 01-JAN-00:10 | 5229.12 | 30-JUN-18:00 |
| EnergyTransfer:Zone:M SE APARTMENT | 45.87 | 0.49 | 30-OCT-16:30 | 5039.38 | 23-JUL-13:30 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 15.70 | 0.00 | 02-JAN-11:10 | 4900.32 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 15.70 | 0.00 | 02-JAN-11:10 | 4900.32 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 30.16 | 0.00 | 01-JAN-00:10 | 5039.38 | 23-JUL-13:30 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 30.16 | 0.00 | 01-JAN-00:10 | 5039.38 | 23-JUL-13:30 |
| EnergyTransfer:Zone:M NE APARTMENT | 45.09 | 0.05 | 16-NOV-12:20 | 5285.67 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 23.38 | 0.00 | 08-FEB-13:50 | 5285.67 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 23.38 | 0.00 | 08-FEB-13:50 | 5285.67 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 21.71 | 0.00 | 01-JAN-00:10 | 3915.50 | 28-JUN-10:20 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 21.71 | 0.00 | 01-JAN-00:10 | 3915.50 | 28-JUN-10:20 |
| EnergyTransfer:Zone:M N1 APARTMENT | 29.62 | 0.01 | 19-NOV-11:00 | 3126.65 | 29-JUN-18:30 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 9.49 | 0.00 | 17-JAN-12:40 | 2992.15 | 04-JAN-12:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 9.49 | 0.00 | 17-JAN-12:40 | 2992.15 | 04-JAN-12:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 20.13 | 0.00 | 01-JAN-00:10 | 3126.65 | 29-JUN-18:30 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 20.13 | 0.00 | 01-JAN-00:10 | 3126.65 | 29-JUN-18:30 |
| EnergyTransfer:Zone:M N2 APARTMENT | 29.62 | 0.02 | 05-APR-22:40 | 3100.78 | 29-JUN-18:30 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 9.48 | 0.00 | 17-JAN-12:40 | 2984.68 | 04-JAN-12:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 9.48 | 0.00 | 17-JAN-12:40 | 2984.68 | 04-JAN-12:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 20.14 | 0.00 | 01-JAN-00:10 | 3100.78 | 29-JUN-18:30 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 20.14 | 0.00 | 01-JAN-00:10 | 3100.78 | 29-JUN-18:30 |
| EnergyTransfer:Zone:M S1 APARTMENT | 35.33 | 0.07 | 13-MAR-02:30 | 4194.39 | 01-SEP-13:30 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 4.45 | 0.00 | 01-JAN-10:20 | 2381.96 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 4.45 | 0.00 | 01-JAN-10:20 | 2381.96 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 30.87 | 0.00 | 01-JAN-00:10 | 4194.39 | 01-SEP-13:30 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 30.87 | 0.00 | 01-JAN-00:10 | 4194.39 | 01-SEP-13:30 |
| EnergyTransfer:Zone:M S2 APARTMENT | 35.35 | 0.08 | 16-JAN-09:40 | 4208.98 | 01-SEP-13:30 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 4.45 | 0.00 | 01-JAN-10:20 | 2381.54 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 4.45 | 0.00 | 01-JAN-10:20 | 2381.54 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 30.89 | 0.00 | 01-JAN-00:10 | 4208.98 | 01-SEP-13:30 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 30.89 | 0.00 | 01-JAN-00:10 | 4208.98 | 01-SEP-13:30 |
| EnergyTransfer:Zone:T SW APARTMENT | 33.72 | 0.00 | 06-OCT-13:50 | 4380.26 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 20.59 | 0.00 | 06-JAN-13:50 | 4380.26 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 20.59 | 0.00 | 06-JAN-13:50 | 4380.26 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 13.13 | 0.00 | 01-JAN-00:10 | 3827.55 | 29-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 13.13 | 0.00 | 01-JAN-00:10 | 3827.55 | 29-JUL-16:10 |
| EnergyTransfer:Zone:T NW APARTMENT | 34.68 | 0.06 | 12-MAY-03:30 | 4476.03 | 04-JAN-12:00 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 25.38 | 0.00 | 08-FEB-15:40 | 4476.03 | 04-JAN-12:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 25.38 | 0.00 | 08-FEB-15:40 | 4476.03 | 04-JAN-12:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 9.31 | 0.00 | 01-JAN-00:10 | 3458.24 | 29-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 9.31 | 0.00 | 01-JAN-00:10 | 3458.24 | 29-JUN-17:30 |
| EnergyTransfer:Zone:T SE APARTMENT | 33.38 | 0.01 | 29-SEP-22:40 | 4366.34 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 20.39 | 0.00 | 06-JAN-13:50 | 4366.34 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 20.39 | 0.00 | 06-JAN-13:50 | 4366.34 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 12.99 | 0.00 | 01-JAN-00:10 | 3424.43 | 23-JUL-13:30 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 12.99 | 0.00 | 01-JAN-00:10 | 3424.43 | 23-JUL-13:30 |
| EnergyTransfer:Zone:T NE APARTMENT | 34.29 | 0.02 | 19-MAR-15:40 | 4455.73 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 25.15 | 0.00 | 18-MAR-11:20 | 4455.73 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 25.15 | 0.00 | 18-MAR-11:20 | 4455.73 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 9.14 | 0.00 | 01-JAN-00:10 | 2566.11 | 29-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 9.14 | 0.00 | 01-JAN-00:10 | 2566.11 | 29-JUN-16:10 |
| EnergyTransfer:Zone:T N1 APARTMENT | 23.06 | 0.01 | 29-APR-22:50 | 2874.12 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 15.21 | 0.00 | 10-MAR-16:10 | 2874.12 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 15.21 | 0.00 | 10-MAR-16:10 | 2874.12 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.85 | 0.00 | 01-JAN-00:10 | 2089.31 | 29-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.85 | 0.00 | 01-JAN-00:10 | 2089.31 | 29-JUN-18:00 |
| EnergyTransfer:Zone:T N2 APARTMENT | 23.07 | 0.02 | 21-SEP-06:30 | 2874.01 | 04-JAN-06:00 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 15.21 | 0.00 | 10-MAR-16:10 | 2874.01 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 15.21 | 0.00 | 10-MAR-16:10 | 2874.01 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.86 | 0.00 | 01-JAN-00:10 | 2060.74 | 29-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.86 | 0.00 | 01-JAN-00:10 | 2060.74 | 29-JUN-18:00 |
| EnergyTransfer:Zone:T S1 APARTMENT | 23.08 | 0.10 | 27-JAN-18:40 | 2848.62 | 01-SEP-13:40 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 11.01 | 0.00 | 01-JAN-12:00 | 2778.04 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 11.01 | 0.00 | 01-JAN-12:00 | 2778.04 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 12.08 | 0.00 | 01-JAN-00:10 | 2848.62 | 01-SEP-13:40 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 12.08 | 0.00 | 01-JAN-00:10 | 2848.62 | 01-SEP-13:40 |
| EnergyTransfer:Zone:T S2 APARTMENT | 23.11 | 0.03 | 05-APR-20:30 | 2862.03 | 01-SEP-13:30 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 11.01 | 0.00 | 01-JAN-12:00 | 2777.95 | 04-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 11.01 | 0.00 | 01-JAN-12:00 | 2777.95 | 04-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 12.10 | 0.00 | 01-JAN-00:10 | 2862.03 | 01-SEP-13:30 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 12.10 | 0.00 | 01-JAN-00:10 | 2862.03 | 01-SEP-13:30 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 996.99 | 0.00 | 09-MAY-14:20 | 117442.06 | 04-JAN-08:10 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 31-AUG-14:30 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 29-JUN-20:20 |
| HeatingCoils:EnergyTransfer | 720.83 | 0.00 | 11-APR-17:30 | 117442.06 | 04-JAN-08:10 |
| CoolingCoils:EnergyTransfer | 276.17 | 0.00 | 01-JAN-00:10 | 106378.24 | 30-JUN-15:10 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 0.153 | -17.507 | 26.258 | -5.716 | 0.000 | 0.000 | 3.933 | 1.454 | 12.213 | 12.871 | 0.000 | 0.037 | 0.000 | 0.000 | -7.215 | 0.000 | -5.796 | -20.686 |
| G NW APARTMENT | 0.155 | -17.371 | 32.022 | -3.869 | 0.000 | 0.000 | 4.011 | 1.454 | 12.213 | 6.266 | 0.000 | 0.038 | 0.000 | 0.000 | -7.678 | 0.000 | -5.713 | -21.528 |
| OFFICE | 0.000 | 0.000 | 8.574 | -9.251 | 0.000 | 0.000 | 2.181 | 7.396 | 9.469 | 12.877 | 0.000 | 0.021 | 0.000 | 0.000 | -6.698 | 0.000 | -4.793 | -19.774 |
| G NE APARTMENT | 0.155 | -17.374 | 31.931 | -3.869 | 0.000 | 0.000 | 4.012 | 1.454 | 12.213 | 6.149 | 0.000 | 0.038 | 0.000 | 0.000 | -7.536 | 0.000 | -5.719 | -21.455 |
| G N1 APARTMENT | 0.155 | -17.416 | 23.950 | -3.214 | 0.000 | 0.000 | 4.001 | 1.454 | 12.213 | 2.201 | 0.000 | 0.023 | 0.000 | 0.000 | -4.886 | 0.000 | -3.701 | -14.780 |
| G N2 APARTMENT | 0.155 | -17.417 | 23.950 | -3.219 | 0.000 | 0.000 | 4.001 | 1.454 | 12.213 | 2.200 | 0.000 | 0.023 | 0.000 | 0.000 | -4.886 | 0.000 | -3.701 | -14.774 |
| G S1 APARTMENT | 0.153 | -17.577 | 18.409 | -5.186 | 0.000 | 0.000 | 3.918 | 1.454 | 12.213 | 8.865 | 0.000 | 0.022 | 0.000 | 0.000 | -4.401 | 0.000 | -3.776 | -14.095 |
| G S2 APARTMENT | 0.153 | -17.585 | 19.953 | -5.771 | 0.000 | 0.000 | 3.916 | 1.454 | 12.213 | 8.865 | 0.000 | 0.022 | 0.000 | 0.000 | -4.392 | 0.000 | -3.778 | -15.052 |
| M SW APARTMENT | 0.306 | -35.433 | 40.335 | -19.448 | 0.000 | 0.000 | 7.779 | 2.908 | 24.426 | 25.317 | 0.000 | 0.105 | 0.000 | 0.000 | -14.984 | 0.000 | -16.532 | -14.778 |
| M NW APARTMENT | 0.306 | -35.138 | 50.713 | -13.997 | 0.000 | 0.000 | 7.933 | 2.908 | 24.426 | 12.186 | 0.000 | 0.105 | 0.000 | 0.000 | -15.992 | 0.000 | -16.345 | -17.106 |
| M SE APARTMENT | 0.306 | -35.437 | 40.139 | -19.468 | 0.000 | 0.000 | 7.783 | 2.908 | 24.426 | 25.170 | 0.000 | 0.105 | 0.000 | 0.000 | -14.779 | 0.000 | -16.538 | -14.614 |
| M NE APARTMENT | 0.306 | -35.140 | 50.486 | -13.989 | 0.000 | 0.000 | 7.938 | 2.908 | 24.426 | 11.946 | 0.000 | 0.105 | 0.000 | 0.000 | -15.693 | 0.000 | -16.358 | -16.933 |
| M N1 APARTMENT | 0.306 | -35.215 | 35.225 | -10.959 | 0.000 | 0.000 | 7.917 | 2.908 | 24.426 | 4.243 | 0.000 | 0.063 | 0.000 | 0.000 | -10.149 | 0.000 | -10.481 | -8.285 |
| M N2 APARTMENT | 0.306 | -35.216 | 35.224 | -10.970 | 0.000 | 0.000 | 7.917 | 2.908 | 24.426 | 4.243 | 0.000 | 0.063 | 0.000 | 0.000 | -10.148 | 0.000 | -10.482 | -8.271 |
| M S1 APARTMENT | 0.306 | -35.596 | 25.349 | -16.481 | 0.000 | 0.000 | 7.746 | 2.908 | 24.426 | 17.499 | 0.000 | 0.063 | 0.000 | 0.000 | -9.120 | 0.000 | -10.654 | -6.446 |
| M S2 APARTMENT | 0.306 | -35.596 | 25.349 | -16.499 | 0.000 | 0.000 | 7.746 | 2.908 | 24.426 | 17.498 | 0.000 | 0.063 | 0.000 | 0.000 | -9.119 | 0.000 | -10.654 | -6.428 |
| T SW APARTMENT | 0.153 | -17.464 | 34.371 | -9.599 | 0.000 | 0.000 | 3.949 | 1.454 | 12.213 | 12.676 | 0.000 | 0.068 | 0.000 | 0.000 | -7.199 | 0.000 | -10.659 | -19.964 |
| T NW APARTMENT | 0.153 | -17.349 | 40.003 | -6.739 | 0.000 | 0.000 | 4.017 | 1.454 | 12.213 | 6.134 | 0.000 | 0.068 | 0.000 | 0.000 | -7.720 | 0.000 | -10.544 | -21.691 |
| T SE APARTMENT | 0.153 | -17.477 | 34.161 | -9.436 | 0.000 | 0.000 | 3.951 | 1.454 | 12.213 | 12.605 | 0.000 | 0.068 | 0.000 | 0.000 | -7.103 | 0.000 | -10.682 | -19.906 |
| T NE APARTMENT | 0.153 | -17.363 | 39.789 | -6.564 | 0.000 | 0.000 | 4.019 | 1.454 | 12.213 | 6.011 | 0.000 | 0.068 | 0.000 | 0.000 | -7.572 | 0.000 | -10.581 | -21.627 |
| T N1 APARTMENT | 0.153 | -17.388 | 29.559 | -4.955 | 0.000 | 0.000 | 4.008 | 1.454 | 12.213 | 2.150 | 0.000 | 0.041 | 0.000 | 0.000 | -4.918 | 0.000 | -6.704 | -15.612 |
| T N2 APARTMENT | 0.153 | -17.389 | 29.562 | -4.968 | 0.000 | 0.000 | 4.008 | 1.454 | 12.213 | 2.148 | 0.000 | 0.041 | 0.000 | 0.000 | -4.917 | 0.000 | -6.708 | -15.598 |
| T S1 APARTMENT | 0.153 | -17.544 | 24.030 | -7.709 | 0.000 | 0.000 | 3.932 | 1.454 | 12.213 | 8.765 | 0.000 | 0.041 | 0.000 | 0.000 | -4.397 | 0.000 | -6.817 | -14.122 |
| T S2 APARTMENT | 0.153 | -17.544 | 24.034 | -7.736 | 0.000 | 0.000 | 3.933 | 1.454 | 12.213 | 8.764 | 0.000 | 0.041 | 0.000 | 0.000 | -4.395 | 0.000 | -6.818 | -14.098 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.606 | 11.688 | 0.000 | 0.966 | 0.000 | 0.003 | 0.000 | 0.000 | -0.743 | 0.000 | -1.686 | -16.834 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 7.061 | 11.688 | 3.530 | 2.968 | 0.000 | 0.154 | 21.946 | 0.000 | -1.983 | 0.000 | -45.364 | -0.001 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 12.417 | 23.376 | 0.000 | 1.903 | 0.000 | 0.007 | 0.000 | 0.000 | -1.577 | 0.000 | -2.710 | -33.416 |
| Total Facility | 4.753 | -544.535 | 743.377 | -219.613 | 0.000 | 0.000 | 150.633 | 99.229 | 391.594 | 243.483 | 0.000 | 1.497 | 21.946 | 0.000 | -200.199 | 0.000 | -264.292 | -427.873 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 29-JUL-16:07 | 0.00 | 218.96 | 0.00 | -2336.25 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 2148.44 | 0.00 | 44.77 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -918.56 |
| G NW APARTMENT | 30-JUN-18:00 | 0.00 | 203.82 | 0.00 | -2047.90 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1911.89 | 0.00 | 68.86 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -987.96 |
| OFFICE | 05-SEP-08:62 | 0.00 | 0.00 | 0.00 | -6184.09 | 0.00 | 0.00 | 284.40 | 582.92 | 588.62 | 2011.49 | 0.00 | 0.00 | 2820.93 | 0.00 | -0.00 | 0.00 | -104.27 | 0.00 |
| G NE APARTMENT | 29-JUN-18:00 | 0.00 | 289.99 | 0.00 | -1725.98 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 659.34 | 0.00 | 100.07 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -174.72 |
| G N1 APARTMENT | 29-JUN-18:00 | 0.00 | 290.04 | 0.00 | -1504.61 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 486.48 | 0.00 | 60.36 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -183.56 |
| G N2 APARTMENT | 29-JUN-18:00 | 0.00 | 290.04 | 0.00 | -1496.50 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 486.55 | 0.00 | 60.36 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -191.75 |
| G S1 APARTMENT | 01-SEP-15:10 | 0.00 | 84.17 | 0.00 | -1713.67 | 0.00 | 0.00 | 0.00 | 60.76 | 470.90 | 1361.47 | 0.00 | 9.11 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -272.74 |
| G S2 APARTMENT | 23-JUL-15:10 | 0.00 | 203.83 | 0.00 | -1918.66 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 954.12 | 0.00 | 56.17 | 5.66 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 29-JUL-16:10 | 0.00 | 437.72 | 0.00 | -6155.04 | 0.00 | 0.00 | 334.45 | 173.60 | 1177.25 | 4282.21 | 0.00 | 128.28 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -378.47 |
| M NW APARTMENT | 30-JUN-18:00 | 0.00 | 407.37 | 0.00 | -5635.42 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 3807.27 | 0.00 | 197.25 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -479.06 |
| M SE APARTMENT | 23-JUL-13:30 | 0.00 | 407.45 | 0.00 | -5446.75 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 3786.97 | 0.00 | 161.54 | 123.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 28-JUN-10:20 | 0.00 | 350.25 | 0.00 | -4265.69 | 0.00 | 0.00 | 83.61 | 34.72 | 824.07 | 2720.41 | 0.00 | 111.20 | 141.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 29-JUN-18:30 | 0.00 | 527.77 | 0.00 | -3654.49 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1027.62 | 0.00 | 163.80 | 271.72 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 29-JUN-18:30 | 0.00 | 527.78 | 0.00 | -3628.64 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1027.80 | 0.00 | 163.80 | 245.68 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 01-SEP-13:30 | 0.00 | 101.04 | 0.00 | -4295.06 | 0.00 | 0.00 | 0.00 | 34.72 | 765.21 | 4185.83 | 0.00 | 12.56 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -804.31 |
| M S2 APARTMENT | 01-SEP-13:30 | 0.00 | 101.04 | 0.00 | -4309.65 | 0.00 | 0.00 | 0.00 | 34.72 | 765.21 | 4185.73 | 0.00 | 12.56 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -789.61 |
| T SW APARTMENT | 29-JUL-16:07 | 0.00 | 218.77 | 0.00 | -4046.51 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 2121.31 | 0.00 | 84.33 | 779.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 29-JUN-17:30 | 0.00 | 314.01 | 0.00 | -3772.39 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1845.89 | 0.00 | 176.97 | 584.23 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 23-JUL-13:30 | 0.00 | 203.61 | 0.00 | -3628.03 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1873.81 | 0.00 | 106.13 | 960.90 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 29-JUN-16:03 | 0.00 | 354.28 | 0.00 | -2920.66 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 645.07 | 0.00 | 256.38 | 902.54 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 29-JUN-18:00 | 0.00 | 289.75 | 0.00 | -2379.27 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 478.34 | 0.00 | 113.97 | 645.92 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 29-JUN-18:00 | 0.00 | 289.76 | 0.00 | -2350.71 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 478.58 | 0.00 | 113.97 | 617.12 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 01-SEP-13:40 | 0.00 | 56.61 | 0.00 | -2905.03 | 0.00 | 0.00 | 0.00 | 17.36 | 382.60 | 1989.62 | 0.00 | 10.11 | 448.73 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 01-SEP-13:30 | 0.00 | 50.50 | 0.00 | -2912.29 | 0.00 | 0.00 | 0.00 | 17.36 | 382.60 | 2080.71 | 0.00 | 7.97 | 373.14 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 30-JUN-15:10 | 0.00 | 8339.89 | 0.00 | -74484.05 | 0.00 | 0.00 | 1384.88 | 3948.92 | 15334.78 | 34372.76 | 0.00 | 5114.75 | 5988.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 09-JAN-08:05 | -1598.34 | 0.00 | 4138.34 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -945.55 | 0.00 | -416.01 | -1592.97 |
| G NW APARTMENT | 04-JAN-12:00 | -1467.57 | 0.00 | 4343.06 | 0.00 | 0.00 | 0.00 | 48.75 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -512.14 | 0.00 | -1095.25 | -1746.25 |
| OFFICE | 21-FEB-07:01 | 0.00 | 0.00 | 10673.63 | 0.00 | 0.00 | 0.00 | 0.00 | 116.58 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -256.89 | 0.00 | -189.89 | -10637.75 |
| G NE APARTMENT | 05-JAN-08:10 | -1588.62 | 0.00 | 4391.23 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -925.94 | 0.00 | -496.90 | -1870.35 |
| G N1 APARTMENT | 05-JAN-08:16 | -1591.72 | 0.00 | 3421.19 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -546.13 | 0.00 | -300.40 | -1473.52 |
| G N2 APARTMENT | 05-JAN-08:16 | -1591.72 | 0.00 | 3421.13 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -546.13 | 0.00 | -300.40 | -1473.46 |
| G S1 APARTMENT | 09-JAN-08:05 | -1598.44 | 0.00 | 3165.16 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -576.42 | 0.00 | -250.93 | -1153.91 |
| G S2 APARTMENT | 09-JAN-08:05 | -1598.44 | 0.00 | 3354.55 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -574.77 | 0.00 | -250.93 | -1344.95 |
| M SW APARTMENT | 04-JAN-06:00 | -2972.37 | 0.00 | 7885.83 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1811.77 | 0.00 | -2603.63 | -1507.08 |
| M NW APARTMENT | 04-JAN-12:00 | -2934.95 | 0.00 | 8528.00 | 0.00 | 0.00 | 0.00 | 97.50 | 34.72 | 824.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1070.21 | 0.00 | -3149.20 | -2329.92 |
| M SE APARTMENT | 04-JAN-06:00 | -2972.37 | 0.00 | 7872.65 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1789.97 | 0.00 | -2603.63 | -1515.72 |
| M NE APARTMENT | 04-JAN-06:00 | -2972.38 | 0.00 | 8258.00 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1817.03 | 0.00 | -2603.63 | -1874.00 |
| M N1 APARTMENT | 04-JAN-12:00 | -2935.16 | 0.00 | 5927.29 | 0.00 | 0.00 | 0.00 | 97.50 | 34.72 | 824.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -654.53 | 0.00 | -1899.52 | -1394.36 |
| M N2 APARTMENT | 04-JAN-12:00 | -2935.16 | 0.00 | 5919.81 | 0.00 | 0.00 | 0.00 | 97.50 | 34.72 | 824.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -654.59 | 0.00 | -1899.52 | -1386.82 |
| M S1 APARTMENT | 04-JAN-06:00 | -2972.75 | 0.00 | 5354.70 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1090.88 | 0.00 | -1570.44 | -729.65 |
| M S2 APARTMENT | 04-JAN-06:00 | -2972.75 | 0.00 | 5354.28 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1090.89 | 0.00 | -1570.44 | -729.23 |
| T SW APARTMENT | 04-JAN-06:00 | -1486.08 | 0.00 | 5866.30 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -887.91 | 0.00 | -1723.44 | -2273.39 |
| T NW APARTMENT | 04-JAN-12:00 | -1467.42 | 0.00 | 5943.42 | 0.00 | 0.00 | 0.00 | 48.75 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -523.39 | 0.00 | -2084.59 | -2346.15 |
| T SE APARTMENT | 04-JAN-06:00 | -1486.08 | 0.00 | 5852.38 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -876.57 | 0.00 | -1723.44 | -2270.81 |
| T NE APARTMENT | 04-JAN-06:00 | -1486.08 | 0.00 | 5941.77 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -892.42 | 0.00 | -1723.44 | -2344.35 |
| T N1 APARTMENT | 04-JAN-06:00 | -1486.28 | 0.00 | 4360.38 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -551.43 | 0.00 | -1039.53 | -1787.65 |
| T N2 APARTMENT | 04-JAN-06:00 | -1486.28 | 0.00 | 4360.27 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -551.44 | 0.00 | -1039.53 | -1787.53 |
| T S1 APARTMENT | 04-JAN-06:00 | -1486.28 | 0.00 | 4264.30 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -535.05 | 0.00 | -1039.53 | -1707.95 |
| T S2 APARTMENT | 04-JAN-06:00 | -1486.28 | 0.00 | 4264.21 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -535.05 | 0.00 | -1039.53 | -1707.86 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 04-JAN-08:61 | -46540.46 | 0.00 | 125042.81 | 0.00 | 0.00 | 0.00 | 2195.92 | 2872.71 | 12840.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -23572.33 | 0.00 | -30574.08 | -42264.82 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3727 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3727 | 0.0696 | 1.0000 | Not calculated | 0.0260 | 0.0696 | ||
| SPLIT GNW | 0.3400 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3400 | 0.0763 | 1.0000 | Not calculated | 0.0260 | 0.0763 | ||
| SPLIT OFFICE | 0.4077 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4077 | 0.0935 | 1.0000 | Not calculated | 0.0381 | 0.0935 | ||
| SPLIT GNE | 0.3003 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3003 | 0.0864 | 1.0000 | Not calculated | 0.0260 | 0.0864 | ||
| SPLIT GN1 | 0.2688 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2688 | 0.0966 | 1.0000 | Not calculated | 0.0260 | 0.0966 | ||
| SPLIT GN2 | 0.2681 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2681 | 0.0968 | 1.0000 | Not calculated | 0.0260 | 0.0968 | ||
| SPLIT GS1 | 0.3056 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3056 | 0.0849 | 1.0000 | Not calculated | 0.0260 | 0.0849 | ||
| SPLIT GS2 | 0.3074 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3074 | 0.0844 | 1.0000 | Not calculated | 0.0260 | 0.0844 | ||
| SPLIT MSW | 0.9297 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9297 | 0.0558 | 1.0000 | Not calculated | 0.0519 | 0.0558 | ||
| SPLIT MNW | 0.8764 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8764 | 0.0592 | 1.0000 | Not calculated | 0.0519 | 0.0592 | ||
| SPLIT MSE | 0.7991 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7991 | 0.0650 | 1.0000 | Not calculated | 0.0519 | 0.0650 | ||
| SPLIT MNE | 0.7475 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7475 | 0.0694 | 1.0000 | Not calculated | 0.0519 | 0.0694 | ||
| SPLIT MN1 | 0.6689 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6689 | 0.0776 | 1.0000 | Not calculated | 0.0519 | 0.0776 | ||
| SPLIT MN2 | 0.6668 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6668 | 0.0779 | 1.0000 | Not calculated | 0.0519 | 0.0779 | ||
| SPLIT MS1 | 0.7295 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7295 | 0.0712 | 1.0000 | Not calculated | 0.0519 | 0.0712 | ||
| SPLIT MS2 | 0.7272 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7272 | 0.0714 | 1.0000 | Not calculated | 0.0519 | 0.0714 | ||
| SPLIT TSW | 0.5053 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5053 | 0.0514 | 1.0000 | Not calculated | 0.0260 | 0.0514 | ||
| SPLIT TNW | 0.4896 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4896 | 0.0530 | 1.0000 | Not calculated | 0.0260 | 0.0530 | ||
| SPLIT TSE | 0.4111 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4111 | 0.0631 | 1.0000 | Not calculated | 0.0260 | 0.0631 | ||
| SPLIT TNE | 0.3955 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3955 | 0.0656 | 1.0000 | Not calculated | 0.0260 | 0.0656 | ||
| SPLIT TN1 | 0.3711 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3711 | 0.0699 | 1.0000 | Not calculated | 0.0260 | 0.0699 | ||
| SPLIT TN2 | 0.3682 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3682 | 0.0705 | 1.0000 | Not calculated | 0.0260 | 0.0705 | ||
| SPLIT TS1 | 0.3891 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3891 | 0.0667 | 1.0000 | Not calculated | 0.0260 | 0.0667 | ||
| SPLIT TS2 | 0.3863 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3863 | 0.0672 | 1.0000 | Not calculated | 0.0260 | 0.0672 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3727 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3727 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0696 | ||
| SPLIT GNW | 0.3400 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3400 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0763 | ||
| SPLIT OFFICE | 0.4077 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4077 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0935 | ||
| SPLIT GNE | 0.3003 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3003 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0864 | ||
| SPLIT GN1 | 0.2688 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2688 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0966 | ||
| SPLIT GN2 | 0.2681 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2681 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0968 | ||
| SPLIT GS1 | 0.3056 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3056 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0849 | ||
| SPLIT GS2 | 0.3074 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3074 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0844 | ||
| SPLIT MSW | 0.9297 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.9297 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0558 | ||
| SPLIT MNW | 0.8764 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8764 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0592 | ||
| SPLIT MSE | 0.7991 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7991 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0650 | ||
| SPLIT MNE | 0.7475 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7475 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0694 | ||
| SPLIT MN1 | 0.6689 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6689 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0776 | ||
| SPLIT MN2 | 0.6668 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6668 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0779 | ||
| SPLIT MS1 | 0.7295 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7295 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0712 | ||
| SPLIT MS2 | 0.7272 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7272 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0714 | ||
| SPLIT TSW | 0.5053 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.5053 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0514 | ||
| SPLIT TNW | 0.4896 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4896 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0530 | ||
| SPLIT TSE | 0.4111 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4111 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0631 | ||
| SPLIT TNE | 0.3955 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3955 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0656 | ||
| SPLIT TN1 | 0.3711 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3711 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0699 | ||
| SPLIT TN2 | 0.3682 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3682 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0705 | ||
| SPLIT TS1 | 0.3891 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3891 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0667 | ||
| SPLIT TS2 | 0.3863 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3863 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0672 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3727 | 0.3727 | 0.3727 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3400 | 0.3400 | 0.3400 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4077 | 0.4077 | 0.4077 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3003 | 0.3003 | 0.3003 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2688 | 0.2688 | 0.2688 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2681 | 0.2681 | 0.2681 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3056 | 0.3056 | 0.3056 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3074 | 0.3074 | 0.3074 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9297 | 0.9297 | 0.9297 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8764 | 0.8764 | 0.8764 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7991 | 0.7991 | 0.7991 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7475 | 0.7475 | 0.7475 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6689 | 0.6689 | 0.6689 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6668 | 0.6668 | 0.6668 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7295 | 0.7295 | 0.7295 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7272 | 0.7272 | 0.7272 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5053 | 0.5053 | 0.5053 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4896 | 0.4896 | 0.4896 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4111 | 0.4111 | 0.4111 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3955 | 0.3955 | 0.3955 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3711 | 0.3711 | 0.3711 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3682 | 0.3682 | 0.3682 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3891 | 0.3891 | 0.3891 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3863 | 0.3863 | 0.3863 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3727 | 0.3727 | 0.3727 | 0.3727 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3400 | 0.3400 | 0.3400 | 0.3400 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4077 | 0.4077 | 0.4077 | 0.4077 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3003 | 0.3003 | 0.3003 | 0.3003 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2688 | 0.2688 | 0.2688 | 0.2688 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2681 | 0.2681 | 0.2681 | 0.2681 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3056 | 0.3056 | 0.3056 | 0.3056 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3074 | 0.3074 | 0.3074 | 0.3074 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.9297 | 0.9297 | 0.9297 | 0.9297 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8764 | 0.8764 | 0.8764 | 0.8764 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7991 | 0.7991 | 0.7991 | 0.7991 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7475 | 0.7475 | 0.7475 | 0.7475 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6689 | 0.6689 | 0.6689 | 0.6689 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6668 | 0.6668 | 0.6668 | 0.6668 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7295 | 0.7295 | 0.7295 | 0.7295 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.7272 | 0.7272 | 0.7272 | 0.7272 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5053 | 0.5053 | 0.5053 | 0.5053 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4896 | 0.4896 | 0.4896 | 0.4896 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4111 | 0.4111 | 0.4111 | 0.4111 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3955 | 0.3955 | 0.3955 | 0.3955 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3711 | 0.3711 | 0.3711 | 0.3711 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3682 | 0.3682 | 0.3682 | 0.3682 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3891 | 0.3891 | 0.3891 | 0.3891 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3863 | 0.3863 | 0.3863 | 0.3863 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3727 | 0.3727 | 0.3727 | No | 0.0260 | 0.1555 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3400 | 0.3400 | 0.3400 | No | 0.0260 | 0.1629 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4077 | 0.4077 | 0.4077 | No | 0.0381 | 0.1907 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3003 | 0.3003 | 0.3003 | No | 0.0260 | 0.1634 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2688 | 0.2688 | 0.2688 | No | 0.0260 | 0.2472 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2681 | 0.2681 | 0.2681 | No | 0.0260 | 0.2472 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3056 | 0.3056 | 0.3056 | No | 0.0260 | 0.2304 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3074 | 0.3074 | 0.3074 | No | 0.0260 | 0.2291 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9297 | 0.9297 | 0.9297 | No | 0.0519 | 0.1927 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8764 | 0.8764 | 0.8764 | No | 0.0519 | 0.2065 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7991 | 0.7991 | 0.7991 | No | 0.0519 | 0.1936 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7475 | 0.7475 | 0.7475 | No | 0.0519 | 0.2075 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6689 | 0.6689 | 0.6689 | No | 0.0519 | 0.3723 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6668 | 0.6668 | 0.6668 | No | 0.0519 | 0.3723 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7295 | 0.7295 | 0.7295 | No | 0.0519 | 0.3306 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7272 | 0.7272 | 0.7272 | No | 0.0519 | 0.3307 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5053 | 0.5053 | 0.5053 | No | 0.0260 | 0.1179 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4896 | 0.4896 | 0.4896 | No | 0.0260 | 0.1234 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4111 | 0.4111 | 0.4111 | No | 0.0260 | 0.1184 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3955 | 0.3955 | 0.3955 | No | 0.0260 | 0.1240 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3711 | 0.3711 | 0.3711 | No | 0.0260 | 0.1830 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3682 | 0.3682 | 0.3682 | No | 0.0260 | 0.1830 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3891 | 0.3891 | 0.3891 | No | 0.0260 | 0.1710 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3863 | 0.3863 | 0.3863 | No | 0.0260 | 0.1710 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3727 | 0.3727 | 0.3727 | 0.3727 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3400 | 0.3400 | 0.3400 | 0.3400 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4077 | 0.4077 | 0.4077 | 0.4077 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3003 | 0.3003 | 0.3003 | 0.3003 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2688 | 0.2688 | 0.2688 | 0.2688 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2681 | 0.2681 | 0.2681 | 0.2681 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3056 | 0.3056 | 0.3056 | 0.3056 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3074 | 0.3074 | 0.3074 | 0.3074 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.9297 | 0.9297 | 0.9297 | 0.9297 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8764 | 0.8764 | 0.8764 | 0.8764 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7991 | 0.7991 | 0.7991 | 0.7991 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7475 | 0.7475 | 0.7475 | 0.7475 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6689 | 0.6689 | 0.6689 | 0.6689 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6668 | 0.6668 | 0.6668 | 0.6668 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7295 | 0.7295 | 0.7295 | 0.7295 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.7272 | 0.7272 | 0.7272 | 0.7272 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.5053 | 0.5053 | 0.5053 | 0.5053 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4896 | 0.4896 | 0.4896 | 0.4896 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4111 | 0.4111 | 0.4111 | 0.4111 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3955 | 0.3955 | 0.3955 | 0.3955 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3711 | 0.3711 | 0.3711 | 0.3711 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3682 | 0.3682 | 0.3682 | 0.3682 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3891 | 0.3891 | 0.3891 | 0.3891 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3863 | 0.3863 | 0.3863 | 0.3863 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 901.04 | 146802.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 69.55 | 28981.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 49.91 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 103.95 | 9280.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 525.06 | 50557.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1306.36 |
| Natural Gas | 0.00 | 901.04 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 2207.40 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 22.19 |
| Fans (All) | 33.16 |
| Service Water Heating | 167.51 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 416.75 |
| Subtotal | 416.75 |
| Natural Gas [MJ/m2] | |
| Space Heating | 287.45 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 287.45 |
| Subtotal | 287.45 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 4.50 |
| Space Heating | 40.82 |
| Space Cooling | 3.15 |
| Fans (All) | 4.71 |
| Service Water Heating | 23.79 |
| Receptacle Equipment | 20.78 |
| Miscellaneous | 2.26 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7988.67 | 770.83 | 0.50 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 7465.50 | 1242.33 | 52.17 | 0.00 | 0.00 |
| G CORRIDOR | 8385.50 | 374.00 | 0.50 | 0.00 | 0.00 |
| M CORRIDOR | 6333.50 | 2426.50 | 0.00 | 0.00 | 0.00 |
| Min | 6333.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 2426.50 | 52.17 | 0.00 | 0.00 |
| Average | 8579.75 | 178.28 | 1.97 | 0.00 | 0.00 |
| Sum | 231653.17 | 4813.67 | 53.17 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 19840.50 | 3008.33 | 146.17 | 0.00 | 0.00 |
| G CORRIDOR | 21916.33 | 1077.67 | 1.00 | 0.00 | 0.00 |
| M CORRIDOR | 16602.00 | 6393.00 | 0.00 | 0.00 | 0.00 |
| Min | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 21916.33 | 6393.00 | 146.17 | 0.00 | 0.00 |
| Average | 11944.77 | 388.11 | 5.45 | 0.00 | 0.00 |
| Sum | 322508.83 | 10479.00 | 147.17 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 8648.17 | 111.83 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8618.33 | 141.67 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7762.00 | 998.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8609.50 | 150.50 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8614.17 | 145.83 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8614.17 | 145.83 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8652.67 | 107.33 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8686.17 | 73.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8714.17 | 45.83 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8704.67 | 55.33 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8711.17 | 48.83 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8703.50 | 56.50 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8700.33 | 59.67 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8700.33 | 59.67 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8706.83 | 53.17 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8707.00 | 53.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8623.67 | 136.33 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8613.67 | 146.33 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8616.83 | 143.17 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8606.83 | 153.17 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8629.17 | 130.83 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8629.50 | 130.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8637.00 | 123.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8636.33 | 123.67 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 4871.83 | 3723.00 | 165.17 | 0.00 | 0.00 |
| G CORRIDOR | 7322.17 | 1434.00 | 3.83 | 0.00 | 0.00 |
| M CORRIDOR | 3825.67 | 4755.00 | 179.33 | 0.00 | 0.00 |
| Min | 3825.67 | 45.83 | 0.00 | 0.00 | 0.00 |
| Max | 8714.17 | 4755.00 | 179.33 | 0.00 | 0.00 |
| Average | 8254.29 | 492.81 | 12.90 | 0.00 | 0.00 |
| Sum | 222865.83 | 13305.83 | 348.33 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 11676.50 | 153.50 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10423.00 | 162.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6889.33 | 110.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10397.00 | 188.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10418.17 | 166.83 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10418.17 | 166.83 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11683.17 | 146.83 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11728.50 | 101.50 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11774.33 | 55.67 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10533.33 | 51.67 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11759.00 | 71.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10521.33 | 63.67 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10529.00 | 56.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10528.00 | 57.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11758.67 | 71.33 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11758.67 | 71.33 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11624.00 | 206.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10396.17 | 188.83 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11602.67 | 227.33 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10365.33 | 219.67 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10433.17 | 151.83 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10432.83 | 152.17 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11654.50 | 175.50 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11653.17 | 176.83 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 12758.67 | 9769.67 | 466.67 | 0.00 | 0.00 |
| G CORRIDOR | 18639.33 | 4340.33 | 15.33 | 0.00 | 0.00 |
| M CORRIDOR | 10005.00 | 12530.50 | 459.50 | 0.00 | 0.00 |
| Min | 6889.33 | 51.67 | 0.00 | 0.00 | 0.00 |
| Max | 18639.33 | 12530.50 | 466.67 | 0.00 | 0.00 |
| Average | 11198.56 | 1104.91 | 34.87 | 0.00 | 0.00 |
| Sum | 302361.00 | 29832.50 | 941.50 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:42
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | -16.89 |
| February | -11.56 |
| March | -6.15 |
| April | 3.968 |
| May | 13.433 |
| June | 18.029 |
| July | 19.667 |
| August | 17.942 |
| September | 12.293 |
| October | 5.424 |
| November | -2.00 |
| December | -14.64 |
| Annual Sum or Average | 3.363 |
| Minimum of Months | -16.89 |
| Maximum of Months | 19.667 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1259496.21 | 183.03 | 27-JAN-15:30 | -14.4 | -15.6 | 78198344.20 | 42.51 | 03-JAN-18:00 | -14.4 | -15.6 |
| February | 30547257.03 | 480.34 | 22-FEB-16:10 | -0.7 | -3.9 | 69629529.72 | 42.97 | 20-FEB-16:30 | -0.7 | -3.9 |
| March | 78538341.36 | 549.93 | 17-MAR-16:02 | -1.8 | -5.6 | 75137936.96 | 49.96 | 26-MAR-16:40 | 10.37 | 5.10 |
| April | 0.275040E+09 | 696.16 | 23-APR-16:10 | 26.60 | 16.90 | 78546197.36 | 70.27 | 23-APR-16:49 | 26.20 | 16.72 |
| May | 0.950900E+09 | 1528.89 | 18-MAY-16:10 | 28.45 | 16.28 | 0.103556E+09 | 70.37 | 19-MAY-20:49 | 12.98 | 10.55 |
| June | 0.139496E+10 | 2056.49 | 30-JUN-17:17 | 30.73 | 21.04 | 0.112490E+09 | 70.37 | 14-JUN-21:00 | 30.73 | 21.04 |
| July | 0.227411E+10 | 2117.29 | 29-JUL-16:07 | 30.50 | 21.35 | 0.128912E+09 | 70.35 | 11-JUL-03:20 | 30.50 | 21.35 |
| August | 0.209407E+10 | 2086.80 | 25-AUG-16:04 | 28.22 | 19.40 | 0.122973E+09 | 70.36 | 02-AUG-03:20 | 28.22 | 19.40 |
| September | 0.145387E+10 | 2101.12 | 01-SEP-16:04 | 25.82 | 17.71 | 0.113589E+09 | 70.36 | 09-SEP-04:49 | 12.30 | 6.72 |
| October | 0.705048E+09 | 1309.78 | 22-OCT-15:30 | 19.15 | 12.57 | 88198533.11 | 70.31 | 01-OCT-18:30 | 19.15 | 12.57 |
| November | 71722418.32 | 481.50 | 17-NOV-18:01 | 4.50 | 0.01 | 75024467.72 | 48.16 | 01-NOV-17:49 | 4.50 | 0.01 |
| December | 696616.00 | 138.17 | 02-DEC-15:10 | -17.4 | -18.2 | 78198344.19 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.933076E+10 | 0.112445E+10 | ||||||||
| Minimum of Months | 696616.00 | 138.17 | -17.4 | -18.2 | 69629529.72 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.227411E+10 | 2117.29 | 30.73 | 21.35 | 0.128912E+09 | 70.37 | 30.73 | 21.35 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.69 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.41 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 2758206.99 | 212.71 | 28-MAR-17:09 | 7.20 | 3.39 | 77895344.63 | 42.51 | 05-MAR-22:00 | 7.20 | 3.39 |
| April | 63800989.25 | 379.36 | 21-APR-19:20 | 7.93 | 0.72 | 76258773.75 | 61.19 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.666929E+09 | 1224.86 | 25-MAY-18:30 | 28.30 | 18.90 | 0.100637E+09 | 70.36 | 27-MAY-00:40 | 15.63 | 13.69 |
| June | 0.118218E+10 | 1844.50 | 30-JUN-18:00 | 30.00 | 20.32 | 0.115601E+09 | 70.37 | 17-JUN-23:49 | 30.00 | 20.32 |
| July | 0.188178E+10 | 1727.07 | 24-JUL-17:45 | 28.40 | 19.34 | 0.128247E+09 | 70.35 | 08-JUL-21:00 | 28.40 | 19.34 |
| August | 0.153897E+10 | 1579.70 | 08-AUG-17:05 | 29.22 | 22.95 | 0.127214E+09 | 70.35 | 22-AUG-02:09 | 15.92 | 12.45 |
| September | 0.955969E+09 | 1372.20 | 01-SEP-16:25 | 25.25 | 17.82 | 0.105921E+09 | 70.36 | 10-SEP-20:10 | 12.80 | 10.14 |
| October | 0.321129E+09 | 512.91 | 01-OCT-02:30 | 3.60 | 3.13 | 79879174.43 | 54.83 | 01-OCT-20:10 | 11.60 | 8.28 |
| November | 7651797.12 | 287.14 | 01-NOV-19:00 | 11.10 | 9.84 | 75406436.23 | 42.68 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.69 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.662117E+10 | 0.111321E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.41 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.188178E+10 | 1844.50 | 30.00 | 22.95 | 0.128247E+09 | 70.37 | 30.00 | 20.32 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.212236E+09 | 2023.74 | 06-JAN-07:03 | -35.0 | -35.1 | 38868446.44 | 80.76 | 03-JAN-13:09 | -35.0 | -35.1 |
| February | 0.378789E+09 | 1937.49 | 14-FEB-07:03 | -33.0 | -33.2 | 36924998.50 | 80.76 | 01-FEB-13:20 | -33.0 | -33.2 |
| March | 0.567075E+09 | 1582.31 | 15-MAR-07:03 | -23.7 | -23.9 | 44738047.88 | 87.14 | 31-MAR-15:20 | 8.50 | 3.01 |
| April | 0.513781E+09 | 1086.18 | 05-APR-06:03 | -13.5 | -14.0 | 45386288.96 | 135.57 | 18-APR-12:20 | 18.30 | 10.77 |
| May | 0.635643E+09 | 5960.89 | 19-MAY-08:62 | 15.27 | 11.36 | 68888782.10 | 184.22 | 26-MAY-07:10 | 20.08 | 16.35 |
| June | 0.114641E+10 | 5975.28 | 15-JUN-08:62 | 16.28 | 11.33 | 76583010.35 | 217.47 | 30-JUN-07:10 | 26.02 | 21.73 |
| July | 0.156997E+10 | 6032.36 | 06-JUL-07:02 | 16.88 | 14.11 | 70393926.08 | 217.47 | 24-JUL-07:10 | 20.97 | 18.41 |
| August | 0.154674E+10 | 6064.64 | 14-AUG-07:02 | 15.10 | 13.70 | 80713670.42 | 204.21 | 09-AUG-07:10 | 15.10 | 13.70 |
| September | 0.101753E+10 | 6184.05 | 05-SEP-08:62 | 11.28 | 8.90 | 67473032.85 | 186.30 | 01-SEP-07:10 | 11.28 | 8.90 |
| October | 0.715374E+09 | 1318.40 | 20-OCT-14:30 | 18.90 | 10.07 | 53360603.67 | 135.90 | 23-OCT-08:09 | 5.68 | 4.09 |
| November | 0.614132E+09 | 1293.58 | 29-NOV-07:03 | -18.4 | -18.7 | 39407220.12 | 107.62 | 01-NOV-15:00 | -18.4 | -18.7 |
| December | 0.333890E+09 | 1758.27 | 20-DEC-07:03 | -29.1 | -29.3 | 38868440.06 | 80.76 | 04-DEC-13:09 | -29.1 | -29.3 |
| Annual Sum or Average | 0.925157E+10 | 0.661606E+09 | ||||||||
| Minimum of Months | 0.212236E+09 | 1086.18 | -35.0 | -35.1 | 36924998.50 | 80.76 | -35.0 | -35.1 | ||
| Maximum of Months | 0.156997E+10 | 6184.05 | 18.90 | 14.11 | 80713670.42 | 217.47 | 26.02 | 21.73 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.69 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.41 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.3 | 77895344.63 | 42.51 | 05-MAR-22:00 | -13.3 | -14.1 |
| April | 55887409.12 | 279.16 | 22-APR-20:10 | 11.23 | 4.51 | 75921927.15 | 56.26 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.636485E+09 | 778.95 | 25-MAY-18:00 | 29.40 | 19.26 | 99292184.20 | 70.36 | 18-MAY-23:19 | 29.40 | 19.26 |
| June | 0.123251E+10 | 1435.84 | 29-JUN-18:00 | 32.80 | 24.21 | 0.116589E+09 | 70.35 | 22-JUN-01:00 | 32.80 | 24.21 |
| July | 0.189573E+10 | 1389.59 | 23-JUL-16:05 | 29.72 | 22.65 | 0.128000E+09 | 70.36 | 07-JUL-23:30 | 29.72 | 22.65 |
| August | 0.151303E+10 | 1318.32 | 08-AUG-16:20 | 30.20 | 23.02 | 0.127221E+09 | 70.36 | 20-AUG-23:40 | 13.33 | 12.02 |
| September | 0.947073E+09 | 1081.03 | 01-SEP-16:15 | 25.53 | 17.77 | 0.105751E+09 | 70.36 | 10-SEP-21:00 | 12.80 | 10.59 |
| October | 0.302130E+09 | 510.02 | 01-OCT-07:30 | 3.65 | 3.28 | 79581447.08 | 53.94 | 01-OCT-20:10 | 11.60 | 8.28 |
| November | 7722604.72 | 286.88 | 01-NOV-19:00 | 11.10 | 9.84 | 75405241.68 | 42.61 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.69 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.659057E+10 | 0.111181E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.41 | 42.51 | -13.3 | -14.1 | ||
| Maximum of Months | 0.189573E+10 | 1435.84 | 32.80 | 24.21 | 0.128000E+09 | 70.36 | 32.80 | 24.21 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.68 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.47 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 897072.64 | 88.71 | 28-MAR-16:15 | 7.20 | 3.35 | 77895344.65 | 42.51 | 05-MAR-22:00 | 7.20 | 3.35 |
| April | 86510124.56 | 380.33 | 24-APR-18:50 | 7.88 | 4.50 | 75928236.46 | 56.75 | 23-APR-20:10 | 7.88 | 4.50 |
| May | 0.682812E+09 | 750.54 | 25-MAY-18:50 | 27.57 | 18.64 | 0.101775E+09 | 70.37 | 17-MAY-21:40 | 27.57 | 18.64 |
| June | 0.108650E+10 | 1214.47 | 29-JUN-18:00 | 32.80 | 24.21 | 0.118851E+09 | 70.38 | 15-JUN-22:10 | 32.80 | 24.21 |
| July | 0.161029E+10 | 1109.98 | 23-JUL-16:30 | 29.15 | 22.29 | 0.128494E+09 | 70.36 | 18-JUL-00:10 | 29.15 | 22.29 |
| August | 0.135638E+10 | 1051.96 | 08-AUG-17:17 | 29.03 | 22.85 | 0.128100E+09 | 70.37 | 17-AUG-20:49 | 13.22 | 11.07 |
| September | 0.946899E+09 | 898.94 | 01-SEP-17:10 | 24.32 | 17.92 | 0.110023E+09 | 70.37 | 08-SEP-00:40 | 14.97 | 12.62 |
| October | 0.516010E+09 | 620.72 | 01-OCT-06:00 | 0.00 | -0.2 | 80442282.14 | 56.37 | 01-OCT-20:10 | 11.60 | 8.28 |
| November | 29645612.53 | 296.28 | 01-NOV-19:00 | 11.10 | 9.84 | 75457176.57 | 45.90 | 01-NOV-20:19 | 13.13 | 11.42 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.68 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.631593E+10 | 0.112311E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.47 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.161029E+10 | 1214.47 | 32.80 | 24.21 | 0.128494E+09 | 70.38 | 32.80 | 24.21 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.68 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.47 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 734656.72 | 83.99 | 28-MAR-16:15 | 7.20 | 3.35 | 77895344.65 | 42.51 | 05-MAR-22:00 | 7.20 | 3.35 |
| April | 85975139.02 | 368.20 | 24-APR-17:18 | 8.30 | 4.68 | 75919652.65 | 56.49 | 23-APR-20:10 | 8.30 | 4.68 |
| May | 0.680042E+09 | 736.92 | 25-MAY-18:50 | 27.57 | 18.64 | 0.101669E+09 | 70.37 | 29-MAY-03:30 | 15.30 | 11.68 |
| June | 0.109366E+10 | 1206.35 | 29-JUN-18:00 | 32.80 | 24.21 | 0.118988E+09 | 70.36 | 17-JUN-23:40 | 32.80 | 24.21 |
| July | 0.161020E+10 | 1104.58 | 23-JUL-16:30 | 29.15 | 22.29 | 0.128478E+09 | 70.35 | 09-JUL-22:49 | 29.15 | 22.29 |
| August | 0.135625E+10 | 1046.51 | 08-AUG-17:17 | 29.03 | 22.85 | 0.128102E+09 | 70.36 | 21-AUG-03:00 | 14.40 | 13.41 |
| September | 0.947871E+09 | 894.38 | 01-SEP-16:30 | 25.25 | 17.82 | 0.110034E+09 | 70.37 | 10-SEP-21:49 | 12.80 | 10.56 |
| October | 0.513635E+09 | 615.97 | 01-OCT-05:50 | 0.18 | -0.1 | 80416168.00 | 56.29 | 01-OCT-20:10 | 11.60 | 8.28 |
| November | 29662342.31 | 296.30 | 01-NOV-19:00 | 11.10 | 9.84 | 75457376.64 | 45.90 | 01-NOV-20:19 | 13.13 | 11.42 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.68 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.631803E+10 | 0.112311E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.47 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.161020E+10 | 1206.35 | 32.80 | 24.21 | 0.128478E+09 | 70.37 | 32.80 | 24.21 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 9212566.99 | 404.79 | 27-JAN-14:30 | -14.4 | -15.6 | 78198344.15 | 42.51 | 03-JAN-18:00 | -14.4 | -15.6 |
| February | 88295090.30 | 639.96 | 22-FEB-13:40 | -0.8 | -3.9 | 69635605.62 | 44.63 | 20-FEB-16:19 | -0.8 | -3.9 |
| March | 0.151113E+09 | 590.27 | 20-MAR-13:40 | 0.97 | -0.8 | 75117459.76 | 49.28 | 26-MAR-16:19 | 10.73 | 5.29 |
| April | 0.443171E+09 | 620.55 | 21-APR-22:00 | 0.00 | -3.7 | 79003148.25 | 70.27 | 23-APR-16:40 | 26.30 | 16.77 |
| May | 0.980887E+09 | 1082.51 | 18-MAY-15:10 | 28.83 | 16.55 | 0.105872E+09 | 70.37 | 29-MAY-05:40 | 14.10 | 11.19 |
| June | 0.131619E+10 | 1483.84 | 30-JUN-15:10 | 32.12 | 24.53 | 0.115801E+09 | 70.37 | 14-JUN-22:30 | 32.12 | 24.53 |
| July | 0.201854E+10 | 1574.48 | 23-JUL-15:10 | 30.00 | 22.52 | 0.129142E+09 | 70.35 | 08-JUL-23:30 | 30.00 | 22.52 |
| August | 0.193739E+10 | 1575.79 | 25-AUG-15:10 | 28.30 | 19.24 | 0.123578E+09 | 70.34 | 16-AUG-01:19 | 28.30 | 19.24 |
| September | 0.148697E+10 | 1629.60 | 01-SEP-15:10 | 26.10 | 17.79 | 0.117587E+09 | 70.37 | 23-SEP-18:00 | 7.80 | 6.68 |
| October | 0.970436E+09 | 1225.61 | 22-OCT-14:00 | 19.40 | 12.77 | 91877148.34 | 70.38 | 19-OCT-19:49 | 19.40 | 12.77 |
| November | 0.245129E+09 | 690.30 | 10-NOV-13:20 | -2.4 | -5.1 | 75122579.91 | 50.71 | 01-NOV-17:49 | -2.4 | -5.1 |
| December | 8973849.56 | 414.58 | 02-DEC-14:30 | -17.6 | -18.5 | 78198344.15 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.965631E+10 | 0.113913E+10 | ||||||||
| Minimum of Months | 8973849.56 | 404.79 | -17.6 | -18.5 | 69635605.62 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.201854E+10 | 1629.60 | 32.12 | 24.53 | 0.129142E+09 | 70.38 | 32.12 | 24.53 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 5870003.37 | 347.31 | 27-JAN-14:30 | -14.4 | -15.6 | 78198344.16 | 42.51 | 03-JAN-18:00 | -14.4 | -15.6 |
| February | 62126889.48 | 563.49 | 22-FEB-14:30 | -0.6 | -3.8 | 69628636.61 | 42.52 | 20-FEB-16:19 | -0.6 | -3.8 |
| March | 0.118179E+09 | 577.25 | 20-MAR-13:20 | 1.33 | -0.9 | 75052727.41 | 47.20 | 26-MAR-16:19 | 10.73 | 5.29 |
| April | 0.415511E+09 | 620.20 | 21-APR-22:00 | 0.00 | -3.7 | 78828436.38 | 70.27 | 23-APR-16:40 | 26.30 | 16.77 |
| May | 0.101391E+10 | 1126.44 | 18-MAY-15:10 | 28.83 | 16.55 | 0.106249E+09 | 70.35 | 18-MAY-05:00 | 28.83 | 16.55 |
| June | 0.142147E+10 | 1553.16 | 30-JUN-15:10 | 32.12 | 24.53 | 0.116444E+09 | 70.38 | 03-JUN-17:00 | 32.12 | 24.53 |
| July | 0.221177E+10 | 1714.75 | 23-JUL-15:10 | 30.00 | 22.52 | 0.129192E+09 | 70.35 | 09-JUL-23:40 | 30.00 | 22.52 |
| August | 0.210753E+10 | 1679.65 | 26-AUG-14:10 | 26.10 | 19.38 | 0.123649E+09 | 70.36 | 17-AUG-22:30 | 26.10 | 19.38 |
| September | 0.157077E+10 | 1691.23 | 01-SEP-15:10 | 26.10 | 17.79 | 0.118204E+09 | 70.36 | 23-SEP-19:10 | 7.62 | 6.54 |
| October | 0.946881E+09 | 1264.72 | 22-OCT-14:00 | 19.40 | 12.77 | 92174990.33 | 70.37 | 19-OCT-19:40 | 19.40 | 12.77 |
| November | 0.186611E+09 | 678.91 | 10-NOV-13:40 | -2.1 | -4.8 | 75095162.13 | 50.29 | 01-NOV-17:49 | -2.1 | -4.8 |
| December | 4659168.92 | 296.77 | 02-DEC-14:30 | -17.6 | -18.5 | 78198344.16 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.100653E+11 | 0.114092E+10 | ||||||||
| Minimum of Months | 4659168.92 | 296.77 | -17.6 | -18.5 | 69628636.61 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.221177E+10 | 1714.75 | 32.12 | 24.53 | 0.129192E+09 | 70.38 | 32.12 | 24.53 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 59045199.23 | 1062.09 | 27-JAN-16:10 | -14.8 | -15.9 | 78198344.15 | 42.51 | 03-JAN-18:00 | -14.8 | -15.9 |
| February | 0.217407E+09 | 884.83 | 19-FEB-16:30 | -8.9 | -11.0 | 70020551.25 | 59.26 | 20-FEB-16:19 | 8.33 | 2.67 |
| March | 0.478176E+09 | 942.61 | 12-MAR-13:00 | -10.6 | -12.6 | 77685579.79 | 70.30 | 26-MAR-16:00 | 10.00 | 4.91 |
| April | 0.104553E+10 | 2391.37 | 23-APR-16:07 | 26.60 | 16.90 | 90326893.87 | 70.31 | 18-APR-20:19 | 26.60 | 16.90 |
| May | 0.213831E+10 | 2612.71 | 18-MAY-16:03 | 28.45 | 16.28 | 0.118972E+09 | 70.31 | 31-MAY-18:19 | 9.80 | 7.32 |
| June | 0.249466E+10 | 2837.74 | 30-JUN-17:17 | 30.73 | 21.04 | 0.119421E+09 | 70.31 | 13-JUN-03:30 | 30.73 | 21.04 |
| July | 0.306920E+10 | 2858.66 | 29-JUL-16:10 | 30.50 | 21.35 | 0.129206E+09 | 70.30 | 02-JUL-16:49 | 30.50 | 21.35 |
| August | 0.259214E+10 | 2671.70 | 25-AUG-16:04 | 28.22 | 19.40 | 0.123341E+09 | 70.31 | 13-AUG-04:49 | 28.22 | 19.40 |
| September | 0.176266E+10 | 2787.81 | 01-SEP-15:30 | 26.10 | 17.73 | 0.115801E+09 | 70.31 | 22-SEP-18:19 | 12.57 | 8.62 |
| October | 0.965426E+09 | 2066.10 | 22-OCT-15:30 | 19.15 | 12.57 | 91657029.05 | 70.31 | 18-OCT-18:40 | 19.15 | 12.57 |
| November | 0.214259E+09 | 738.05 | 10-NOV-16:45 | -4.0 | -6.1 | 75230851.98 | 52.59 | 01-NOV-17:49 | -4.0 | -6.1 |
| December | 29401194.19 | 1046.35 | 02-DEC-14:40 | -17.5 | -18.3 | 78198344.15 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.150662E+11 | 0.116806E+10 | ||||||||
| Minimum of Months | 29401194.19 | 738.05 | -17.5 | -18.3 | 70020551.25 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.306920E+10 | 2858.66 | 30.73 | 21.35 | 0.129206E+09 | 70.31 | 30.73 | 21.35 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.67 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 4722968.27 | 266.43 | 08-FEB-16:30 | 3.85 | -1.1 | 70357085.40 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 0.102196E+09 | 585.33 | 28-MAR-21:00 | 0.60 | -1.5 | 78202152.69 | 46.87 | 28-MAR-17:40 | 0.60 | -1.5 |
| April | 0.533830E+09 | 1235.67 | 23-APR-17:30 | 25.85 | 16.58 | 83122366.13 | 70.27 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.169464E+10 | 2330.27 | 25-MAY-18:30 | 28.30 | 18.90 | 0.119414E+09 | 70.30 | 16-MAY-00:30 | 28.30 | 18.90 |
| June | 0.222819E+10 | 2614.56 | 30-JUN-18:00 | 30.00 | 20.32 | 0.123620E+09 | 70.32 | 05-JUN-01:10 | 30.00 | 20.32 |
| July | 0.264301E+10 | 2343.07 | 24-JUL-17:25 | 28.60 | 19.24 | 0.128692E+09 | 70.29 | 17-JUL-03:39 | 28.60 | 19.24 |
| August | 0.199399E+10 | 2090.26 | 08-AUG-16:30 | 30.00 | 23.03 | 0.128016E+09 | 70.31 | 17-AUG-04:10 | 15.00 | 14.30 |
| September | 0.113302E+10 | 1831.93 | 01-SEP-16:20 | 25.53 | 17.77 | 0.111370E+09 | 70.31 | 06-SEP-21:49 | 8.98 | 7.47 |
| October | 0.495762E+09 | 632.36 | 01-OCT-06:00 | 0.00 | -0.2 | 83495293.17 | 64.69 | 01-OCT-20:10 | 11.60 | 8.28 |
| November | 24600264.14 | 303.37 | 01-NOV-19:00 | 11.10 | 9.84 | 75504903.22 | 47.47 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.108540E+11 | 0.115758E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -21.9 | -22.1 | 70357085.40 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.264301E+10 | 2614.56 | 30.00 | 23.03 | 0.128692E+09 | 70.32 | 30.00 | 20.32 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 51789012.58 | 1032.73 | 27-JAN-14:00 | -14.4 | -15.6 | 78198344.15 | 42.51 | 03-JAN-18:00 | -14.4 | -15.6 |
| February | 0.207341E+09 | 872.92 | 27-FEB-14:20 | -8.5 | -10.6 | 69871567.02 | 54.06 | 20-FEB-16:10 | -8.5 | -10.6 |
| March | 0.475950E+09 | 985.45 | 12-MAR-10:30 | -12.2 | -14.0 | 76953574.69 | 64.25 | 26-MAR-15:39 | 10.93 | 5.42 |
| April | 0.106148E+10 | 1734.30 | 23-APR-15:20 | 25.97 | 16.64 | 90118073.18 | 70.31 | 11-APR-19:30 | 25.97 | 16.64 |
| May | 0.208275E+10 | 2382.30 | 18-MAY-13:30 | 28.35 | 16.75 | 0.118718E+09 | 70.31 | 16-MAY-01:10 | 28.35 | 16.75 |
| June | 0.258703E+10 | 2417.06 | 30-JUN-14:10 | 31.28 | 23.89 | 0.119512E+09 | 70.31 | 05-JUN-03:30 | 31.28 | 23.89 |
| July | 0.309034E+10 | 2519.69 | 23-JUL-13:30 | 30.00 | 22.65 | 0.129159E+09 | 70.31 | 02-JUL-03:09 | 30.00 | 22.65 |
| August | 0.256480E+10 | 2394.63 | 25-AUG-13:30 | 27.75 | 18.69 | 0.123405E+09 | 70.31 | 25-AUG-05:10 | 27.75 | 18.69 |
| September | 0.176548E+10 | 2466.91 | 01-SEP-13:30 | 25.00 | 18.03 | 0.115546E+09 | 70.31 | 12-SEP-20:19 | 9.40 | 7.87 |
| October | 0.948190E+09 | 1960.19 | 22-OCT-13:30 | 18.85 | 12.94 | 91155427.85 | 70.29 | 19-OCT-22:40 | 18.85 | 12.94 |
| November | 0.218878E+09 | 720.05 | 10-NOV-12:00 | -3.3 | -5.4 | 75220268.98 | 52.46 | 01-NOV-17:49 | -3.3 | -5.4 |
| December | 27896049.34 | 840.10 | 02-DEC-14:00 | -18.1 | -18.9 | 78198344.15 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.150819E+11 | 0.116606E+10 | ||||||||
| Minimum of Months | 27896049.34 | 720.05 | -18.1 | -18.9 | 69871567.02 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.309034E+10 | 2519.69 | 31.28 | 23.89 | 0.129159E+09 | 70.31 | 31.28 | 23.89 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.67 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 265496.87 | 53.83 | 22-FEB-10:00 | -4.4 | -5.9 | 70357085.41 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 87707172.18 | 438.82 | 29-MAR-11:00 | 1.70 | -0.9 | 77913070.18 | 42.51 | 05-MAR-22:00 | 1.70 | -0.9 |
| April | 0.558740E+09 | 677.22 | 13-APR-02:30 | -1.9 | -4.2 | 82338092.49 | 70.27 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.163216E+10 | 1589.32 | 18-MAY-09:50 | 24.98 | 16.17 | 0.119076E+09 | 70.30 | 07-MAY-21:49 | 24.98 | 16.17 |
| June | 0.232066E+10 | 1957.75 | 28-JUN-10:20 | 29.07 | 21.75 | 0.123630E+09 | 70.32 | 06-JUN-00:49 | 29.07 | 21.75 |
| July | 0.266447E+10 | 1872.86 | 29-JUL-10:00 | 26.70 | 19.51 | 0.128610E+09 | 70.31 | 02-JUL-02:30 | 26.70 | 19.51 |
| August | 0.196564E+10 | 1663.58 | 08-AUG-16:04 | 30.40 | 23.01 | 0.128010E+09 | 70.31 | 25-AUG-02:30 | 9.15 | 9.03 |
| September | 0.112752E+10 | 1330.77 | 01-SEP-16:17 | 25.53 | 17.77 | 0.111037E+09 | 70.31 | 17-SEP-22:00 | 12.20 | 12.20 |
| October | 0.476996E+09 | 626.51 | 01-OCT-06:00 | 0.00 | -0.2 | 82844819.33 | 63.51 | 01-OCT-20:10 | 11.60 | 8.28 |
| November | 22408143.27 | 302.94 | 01-NOV-19:00 | 11.10 | 9.84 | 75502485.58 | 47.36 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.108566E+11 | 0.115511E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -21.9 | -22.1 | 70357085.41 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.266447E+10 | 1957.75 | 30.40 | 23.01 | 0.128610E+09 | 70.32 | 29.07 | 21.75 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1766499.58 | 164.69 | 29-JAN-17:03 | -1.4 | -2.6 | 77895344.67 | 42.51 | 02-JAN-22:00 | -1.4 | -2.6 |
| February | 23968912.45 | 265.75 | 08-FEB-18:09 | 0.82 | -2.6 | 70357085.47 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 0.177509E+09 | 543.37 | 28-MAR-20:30 | 2.50 | -0.4 | 77979850.47 | 43.87 | 28-MAR-20:10 | 2.50 | -0.4 |
| April | 0.693689E+09 | 685.72 | 13-APR-02:40 | -2.2 | -4.4 | 82344551.41 | 70.27 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.145643E+10 | 1342.30 | 25-MAY-18:50 | 27.57 | 18.64 | 0.120731E+09 | 70.31 | 19-MAY-23:30 | 27.57 | 18.64 |
| June | 0.186754E+10 | 1563.33 | 29-JUN-18:30 | 31.95 | 23.70 | 0.124258E+09 | 70.31 | 11-JUN-05:49 | 31.95 | 23.70 |
| July | 0.211868E+10 | 1359.74 | 20-JUL-19:00 | 26.70 | 20.55 | 0.128759E+09 | 70.32 | 27-JUL-03:30 | 9.70 | 9.41 |
| August | 0.169081E+10 | 1267.21 | 08-AUG-17:17 | 29.03 | 22.85 | 0.128544E+09 | 70.31 | 13-AUG-03:49 | 10.10 | 9.70 |
| September | 0.109859E+10 | 1061.01 | 01-SEP-16:30 | 25.25 | 17.82 | 0.115978E+09 | 70.31 | 19-SEP-20:19 | 9.03 | 8.53 |
| October | 0.782123E+09 | 680.38 | 04-OCT-03:00 | -1.7 | -1.9 | 85509574.10 | 66.64 | 01-OCT-20:10 | -1.7 | -1.9 |
| November | 0.149560E+09 | 417.98 | 14-NOV-19:00 | 5.00 | 3.25 | 75598621.88 | 50.81 | 01-NOV-20:10 | 5.00 | 3.25 |
| December | 4420889.65 | 156.72 | 05-DEC-18:14 | 0.00 | -0.0 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.100651E+11 | 0.116585E+10 | ||||||||
| Minimum of Months | 1766499.58 | 156.72 | -2.2 | -4.4 | 70357085.47 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.211868E+10 | 1563.33 | 31.95 | 23.70 | 0.128759E+09 | 70.32 | 31.95 | 23.70 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1725399.75 | 162.95 | 29-JAN-17:03 | -1.4 | -2.6 | 77895344.67 | 42.51 | 02-JAN-22:00 | -1.4 | -2.6 |
| February | 23540400.30 | 260.99 | 08-FEB-18:09 | 0.82 | -2.6 | 70357085.47 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 0.176786E+09 | 524.74 | 28-MAR-20:20 | 3.13 | 0.11 | 77968834.63 | 43.54 | 28-MAR-20:10 | 3.13 | 0.11 |
| April | 0.694687E+09 | 685.81 | 13-APR-02:40 | -2.2 | -4.4 | 82343852.89 | 70.27 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.145622E+10 | 1325.67 | 25-MAY-18:50 | 27.57 | 18.64 | 0.120737E+09 | 70.30 | 16-MAY-00:10 | 27.57 | 18.64 |
| June | 0.187201E+10 | 1550.39 | 29-JUN-18:30 | 31.95 | 23.70 | 0.124260E+09 | 70.32 | 17-JUN-01:10 | 31.95 | 23.70 |
| July | 0.211927E+10 | 1347.53 | 20-JUL-19:00 | 26.70 | 20.55 | 0.128756E+09 | 70.31 | 27-JUL-03:49 | 9.90 | 9.57 |
| August | 0.169052E+10 | 1260.19 | 08-AUG-17:17 | 29.03 | 22.85 | 0.128547E+09 | 70.31 | 25-AUG-04:10 | 8.72 | 8.66 |
| September | 0.110042E+10 | 1054.73 | 01-SEP-16:30 | 25.25 | 17.82 | 0.115958E+09 | 70.32 | 09-SEP-00:30 | 12.25 | 7.39 |
| October | 0.780189E+09 | 680.10 | 04-OCT-03:00 | -1.7 | -1.9 | 85438836.71 | 66.53 | 01-OCT-20:10 | -1.7 | -1.9 |
| November | 0.149775E+09 | 417.05 | 02-NOV-16:04 | 3.30 | 1.65 | 75598998.28 | 50.82 | 01-NOV-20:10 | 3.30 | 1.65 |
| December | 4406828.76 | 156.47 | 05-DEC-18:14 | 0.00 | -0.0 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.100695E+11 | 0.116576E+10 | ||||||||
| Minimum of Months | 1725399.75 | 156.47 | -2.2 | -4.4 | 70357085.47 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.211927E+10 | 1550.39 | 31.95 | 23.70 | 0.128756E+09 | 70.32 | 31.95 | 23.70 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.226902E+09 | 1118.61 | 27-JAN-12:20 | -16.7 | -17.5 | 78198344.12 | 42.51 | 03-JAN-18:00 | -16.7 | -17.5 |
| February | 0.507122E+09 | 1018.30 | 10-FEB-13:30 | -13.4 | -14.5 | 70522655.81 | 59.61 | 20-FEB-16:10 | 8.62 | 2.77 |
| March | 0.836384E+09 | 1021.81 | 12-MAR-19:00 | -13.3 | -14.5 | 78204539.29 | 68.18 | 19-MAR-16:19 | 5.00 | 1.65 |
| April | 0.123406E+10 | 1597.31 | 23-APR-15:10 | 25.78 | 16.56 | 93182319.10 | 70.31 | 19-APR-18:30 | 25.78 | 16.56 |
| May | 0.189332E+10 | 1889.17 | 18-MAY-13:40 | 28.40 | 16.75 | 0.120965E+09 | 70.32 | 02-MAY-20:00 | 28.40 | 16.75 |
| June | 0.213445E+10 | 1921.19 | 30-JUN-14:10 | 31.28 | 23.89 | 0.120071E+09 | 70.32 | 16-JUN-04:49 | 31.28 | 23.89 |
| July | 0.254563E+10 | 1989.97 | 23-JUL-13:30 | 30.00 | 22.65 | 0.129265E+09 | 70.30 | 02-JUL-16:49 | 30.00 | 22.65 |
| August | 0.229480E+10 | 1949.88 | 25-AUG-14:10 | 28.30 | 18.89 | 0.123772E+09 | 70.29 | 06-AUG-08:09 | 28.30 | 18.89 |
| September | 0.177001E+10 | 2097.20 | 01-SEP-13:30 | 25.00 | 18.03 | 0.119658E+09 | 70.32 | 26-SEP-22:30 | 9.45 | 9.12 |
| October | 0.129620E+10 | 1927.91 | 22-OCT-13:40 | 19.03 | 12.89 | 96457128.92 | 70.31 | 02-OCT-18:00 | 19.03 | 12.89 |
| November | 0.565677E+09 | 807.83 | 10-NOV-19:00 | -6.1 | -7.8 | 75805062.47 | 56.60 | 17-NOV-18:10 | 4.50 | 0.01 |
| December | 0.132571E+09 | 1196.29 | 02-DEC-12:50 | -19.2 | -19.9 | 78204159.17 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.154371E+11 | 0.118430E+10 | ||||||||
| Minimum of Months | 0.132571E+09 | 807.83 | -19.2 | -19.9 | 70522655.81 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.254563E+10 | 2097.20 | 31.28 | 23.89 | 0.129265E+09 | 70.32 | 31.28 | 23.89 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.227383E+09 | 1118.72 | 27-JAN-12:20 | -16.7 | -17.5 | 78198344.12 | 42.51 | 03-JAN-18:00 | -16.7 | -17.5 |
| February | 0.506662E+09 | 1018.41 | 10-FEB-13:30 | -13.4 | -14.5 | 70511018.20 | 59.54 | 20-FEB-16:10 | 8.62 | 2.77 |
| March | 0.836193E+09 | 1021.45 | 12-MAR-19:00 | -13.3 | -14.5 | 78173158.94 | 68.06 | 19-MAR-16:19 | 5.00 | 1.65 |
| April | 0.123835E+10 | 1593.29 | 23-APR-15:10 | 25.78 | 16.56 | 93215847.64 | 70.31 | 19-APR-18:30 | 25.78 | 16.56 |
| May | 0.189351E+10 | 1894.89 | 18-MAY-13:40 | 28.40 | 16.75 | 0.120955E+09 | 70.30 | 07-MAY-23:49 | 28.40 | 16.75 |
| June | 0.213903E+10 | 1921.00 | 30-JUN-14:10 | 31.28 | 23.89 | 0.120076E+09 | 70.32 | 16-JUN-04:00 | 31.28 | 23.89 |
| July | 0.254639E+10 | 1995.60 | 23-JUL-13:30 | 30.00 | 22.65 | 0.129263E+09 | 70.31 | 09-JUL-02:20 | 30.00 | 22.65 |
| August | 0.229450E+10 | 1955.34 | 25-AUG-14:10 | 28.30 | 18.89 | 0.123776E+09 | 70.28 | 31-AUG-19:00 | 23.30 | 20.62 |
| September | 0.177079E+10 | 2104.49 | 01-SEP-13:30 | 25.00 | 18.03 | 0.119623E+09 | 70.31 | 06-SEP-00:10 | 3.30 | 3.04 |
| October | 0.129526E+10 | 1932.57 | 22-OCT-13:40 | 19.03 | 12.89 | 96389528.33 | 70.31 | 18-OCT-18:40 | 19.03 | 12.89 |
| November | 0.565761E+09 | 807.72 | 10-NOV-19:00 | -6.1 | -7.8 | 75807401.41 | 56.64 | 17-NOV-18:10 | 4.50 | 0.01 |
| December | 0.132998E+09 | 1200.27 | 02-DEC-12:40 | -19.4 | -20.1 | 78204320.10 | 42.51 | 18-DEC-19:10 | -24.1 | -24.6 |
| Annual Sum or Average | 0.154468E+11 | 0.118419E+10 | ||||||||
| Minimum of Months | 0.132998E+09 | 807.72 | -19.4 | -20.1 | 70511018.20 | 42.51 | -24.1 | -24.6 | ||
| Maximum of Months | 0.254639E+10 | 2104.49 | 31.28 | 23.89 | 0.129263E+09 | 70.32 | 31.28 | 23.89 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 31747480.90 | 1063.51 | 27-JAN-15:30 | -14.4 | -15.6 | 78198344.21 | 42.51 | 03-JAN-18:00 | -14.4 | -15.6 |
| February | 0.131857E+09 | 925.70 | 28-FEB-15:30 | 6.10 | 1.55 | 70106548.17 | 69.86 | 20-FEB-16:19 | 6.10 | 1.55 |
| March | 0.319861E+09 | 1601.69 | 19-MAR-16:01 | 5.00 | 1.65 | 77863158.39 | 70.31 | 31-MAR-18:30 | 7.20 | 2.32 |
| April | 0.772812E+09 | 3027.18 | 23-APR-16:03 | 26.60 | 16.90 | 84617436.70 | 70.37 | 11-APR-20:40 | 26.60 | 16.90 |
| May | 0.191806E+10 | 3461.18 | 18-MAY-15:30 | 28.70 | 16.46 | 0.106853E+09 | 70.37 | 22-MAY-23:00 | 16.70 | 11.72 |
| June | 0.243263E+10 | 3722.24 | 30-JUN-16:30 | 31.40 | 23.05 | 0.110696E+09 | 70.36 | 15-JUN-23:10 | 31.40 | 23.05 |
| July | 0.305280E+10 | 3827.73 | 29-JUL-16:07 | 30.50 | 21.35 | 0.125014E+09 | 70.35 | 28-JUL-00:10 | 30.50 | 21.35 |
| August | 0.243652E+10 | 3475.54 | 11-AUG-16:04 | 26.60 | 19.50 | 0.117314E+09 | 70.35 | 22-AUG-00:49 | 16.78 | 13.43 |
| September | 0.135184E+10 | 3684.38 | 01-SEP-15:30 | 26.10 | 17.73 | 0.100274E+09 | 70.35 | 11-SEP-20:19 | 17.03 | 15.08 |
| October | 0.570259E+09 | 2360.82 | 19-OCT-15:20 | 22.03 | 13.60 | 84089150.03 | 70.34 | 22-OCT-19:19 | 9.43 | 7.37 |
| November | 98323701.74 | 701.46 | 10-NOV-13:00 | -2.8 | -5.4 | 75137392.10 | 56.32 | 01-NOV-17:49 | -2.8 | -5.4 |
| December | 14601937.03 | 916.50 | 02-DEC-14:40 | -17.5 | -18.3 | 78198344.22 | 42.51 | 03-DEC-09:09 | -12.1 | -12.2 |
| Annual Sum or Average | 0.131313E+11 | 0.110836E+10 | ||||||||
| Minimum of Months | 14601937.03 | 701.46 | -17.5 | -18.3 | 70106548.17 | 42.51 | -14.4 | -15.6 | ||
| Maximum of Months | 0.305280E+10 | 3827.73 | 31.40 | 23.05 | 0.125014E+09 | 70.37 | 31.40 | 23.05 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.66 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 590612.23 | 130.16 | 08-FEB-16:30 | 3.85 | -1.1 | 70357085.27 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 63050794.95 | 628.48 | 23-MAR-17:50 | -0.4 | -4.0 | 78318827.31 | 53.91 | 26-MAR-17:30 | 9.45 | 4.66 |
| April | 0.318073E+09 | 2013.50 | 23-APR-17:15 | 25.93 | 16.61 | 81549909.61 | 70.27 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.147499E+10 | 3019.09 | 25-MAY-18:00 | 29.40 | 19.26 | 0.108048E+09 | 70.36 | 24-MAY-00:10 | 29.40 | 19.26 |
| June | 0.214019E+10 | 3458.35 | 29-JUN-17:30 | 33.60 | 23.81 | 0.115554E+09 | 70.36 | 05-JUN-22:30 | 33.60 | 23.81 |
| July | 0.259413E+10 | 3066.27 | 29-JUL-17:05 | 29.72 | 21.17 | 0.124940E+09 | 70.36 | 06-JUL-01:49 | 29.72 | 21.17 |
| August | 0.182636E+10 | 2844.41 | 08-AUG-16:30 | 30.00 | 23.03 | 0.121154E+09 | 70.36 | 14-AUG-00:10 | 15.00 | 12.35 |
| September | 0.721960E+09 | 2431.35 | 01-SEP-16:15 | 25.53 | 17.77 | 95759449.83 | 70.33 | 01-SEP-23:19 | 13.53 | 12.76 |
| October | 0.159657E+09 | 488.79 | 26-OCT-19:50 | 4.45 | 3.05 | 80687689.98 | 63.28 | 19-OCT-20:10 | 4.45 | 3.05 |
| November | 8828858.18 | 305.79 | 01-NOV-19:00 | 11.10 | 9.84 | 75504373.28 | 47.25 | 01-NOV-17:49 | 11.10 | 9.84 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.930784E+10 | 0.110766E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -21.9 | -22.1 | 70357085.27 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.259413E+10 | 3458.35 | 33.60 | 23.81 | 0.124940E+09 | 70.36 | 33.60 | 23.81 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 20895065.62 | 999.38 | 27-JAN-14:20 | -14.4 | -15.6 | 78198344.21 | 42.51 | 03-JAN-18:00 | -14.4 | -15.6 |
| February | 0.116076E+09 | 867.66 | 27-FEB-14:30 | -8.3 | -10.5 | 69888257.38 | 59.80 | 20-FEB-16:10 | -8.3 | -10.5 |
| March | 0.290659E+09 | 1017.34 | 23-MAR-14:00 | 0.00 | -4.3 | 77072725.08 | 70.27 | 26-MAR-17:40 | 9.27 | 4.58 |
| April | 0.760239E+09 | 2138.04 | 23-APR-15:20 | 25.97 | 16.64 | 83965421.33 | 70.36 | 21-APR-19:10 | 25.97 | 16.64 |
| May | 0.183220E+10 | 3167.81 | 18-MAY-13:30 | 28.35 | 16.75 | 0.106582E+09 | 70.37 | 29-MAY-01:10 | 15.60 | 11.95 |
| June | 0.249349E+10 | 3317.75 | 30-JUN-13:30 | 31.40 | 24.11 | 0.111369E+09 | 70.35 | 07-JUN-02:30 | 31.40 | 24.11 |
| July | 0.307466E+10 | 3424.43 | 23-JUL-13:30 | 30.00 | 22.65 | 0.124933E+09 | 70.35 | 17-JUL-22:40 | 30.00 | 22.65 |
| August | 0.239437E+10 | 3105.47 | 24-AUG-13:00 | 25.60 | 17.78 | 0.117425E+09 | 70.36 | 22-AUG-00:00 | 25.60 | 17.78 |
| September | 0.134344E+10 | 3285.45 | 01-SEP-13:30 | 25.00 | 18.03 | 99959040.58 | 70.34 | 11-SEP-21:49 | 15.78 | 15.26 |
| October | 0.555073E+09 | 2212.27 | 22-OCT-13:40 | 19.03 | 12.89 | 83844979.13 | 70.30 | 09-OCT-15:00 | 19.03 | 12.89 |
| November | 96760402.09 | 709.15 | 10-NOV-12:30 | -3.0 | -5.4 | 75117476.07 | 55.51 | 01-NOV-17:49 | -3.0 | -5.4 |
| December | 13521832.84 | 640.40 | 02-DEC-14:00 | -18.1 | -18.9 | 78198344.23 | 42.51 | 03-DEC-09:09 | -12.1 | -12.2 |
| Annual Sum or Average | 0.129914E+11 | 0.110655E+10 | ||||||||
| Minimum of Months | 13521832.84 | 640.40 | -18.1 | -18.9 | 69888257.38 | 42.51 | -14.4 | -15.6 | ||
| Maximum of Months | 0.307466E+10 | 3424.43 | 31.40 | 24.11 | 0.124933E+09 | 70.37 | 31.40 | 24.11 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.66 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.28 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 25643750.13 | 358.32 | 28-MAR-17:00 | 7.20 | 3.52 | 77905347.62 | 42.51 | 05-MAR-22:00 | 7.20 | 3.52 |
| April | 0.287679E+09 | 1026.99 | 23-APR-17:15 | 25.93 | 16.61 | 80592181.70 | 70.33 | 23-APR-22:19 | 16.47 | 11.90 |
| May | 0.138081E+10 | 2006.67 | 18-MAY-16:10 | 28.45 | 16.28 | 0.107609E+09 | 70.35 | 10-MAY-23:49 | 28.45 | 16.28 |
| June | 0.220270E+10 | 2566.39 | 29-JUN-16:03 | 34.90 | 24.48 | 0.115958E+09 | 70.36 | 11-JUN-20:19 | 34.90 | 24.48 |
| July | 0.262197E+10 | 2407.12 | 29-JUL-10:20 | 27.07 | 19.65 | 0.124748E+09 | 70.34 | 01-JUL-01:00 | 27.07 | 19.65 |
| August | 0.177713E+10 | 2198.78 | 08-AUG-16:04 | 30.40 | 23.01 | 0.121080E+09 | 70.35 | 08-AUG-01:00 | 30.40 | 23.01 |
| September | 0.689937E+09 | 1670.60 | 01-SEP-16:04 | 25.82 | 17.71 | 95385361.23 | 70.34 | 01-SEP-22:00 | 13.90 | 13.22 |
| October | 0.143715E+09 | 484.03 | 01-OCT-02:00 | 4.40 | 3.91 | 80109878.44 | 60.38 | 19-OCT-20:10 | 13.22 | 10.16 |
| November | 8205607.96 | 303.80 | 01-NOV-19:00 | 11.10 | 9.84 | 75493230.54 | 46.58 | 01-NOV-17:49 | 11.10 | 9.84 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.68 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.913780E+10 | 0.110503E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.28 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.262197E+10 | 2566.39 | 34.90 | 24.48 | 0.124748E+09 | 70.36 | 34.90 | 24.48 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.67 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.41 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 43090499.33 | 418.06 | 28-MAR-18:20 | 6.67 | 2.38 | 77933989.11 | 42.51 | 05-MAR-22:00 | 6.67 | 2.38 |
| April | 0.306552E+09 | 865.61 | 23-APR-18:00 | 25.60 | 16.47 | 80281718.38 | 70.31 | 23-APR-22:49 | 15.37 | 11.19 |
| May | 0.123110E+10 | 1720.70 | 25-MAY-18:30 | 28.30 | 18.90 | 0.109702E+09 | 70.37 | 21-MAY-22:10 | 28.30 | 18.90 |
| June | 0.174101E+10 | 2089.31 | 29-JUN-18:00 | 32.80 | 24.21 | 0.118203E+09 | 70.36 | 16-JUN-22:30 | 32.80 | 24.21 |
| July | 0.206354E+10 | 1848.88 | 23-JUL-16:20 | 29.43 | 22.47 | 0.126289E+09 | 70.35 | 09-JUL-22:40 | 29.43 | 22.47 |
| August | 0.149398E+10 | 1744.48 | 08-AUG-16:15 | 30.20 | 23.02 | 0.123839E+09 | 70.35 | 11-AUG-00:10 | 15.60 | 14.63 |
| September | 0.720342E+09 | 1378.68 | 01-SEP-16:15 | 25.53 | 17.77 | 98198114.73 | 70.35 | 11-SEP-22:19 | 15.60 | 15.40 |
| October | 0.231946E+09 | 502.13 | 26-OCT-20:00 | 3.90 | 2.66 | 80449405.43 | 61.61 | 19-OCT-20:10 | 3.90 | 2.66 |
| November | 13856583.64 | 314.35 | 01-NOV-19:00 | 11.10 | 9.84 | 75559395.70 | 49.87 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.784542E+10 | 0.111660E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.41 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.206354E+10 | 2089.31 | 32.80 | 24.21 | 0.126289E+09 | 70.37 | 32.80 | 24.21 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 77895344.67 | 42.51 | 02-JAN-22:00 | -12.2 | -12.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 70357085.41 | 42.51 | 25-FEB-22:00 | -12.8 | -13.5 |
| March | 41541246.15 | 405.35 | 28-MAR-17:10 | 7.20 | 3.39 | 77921008.77 | 42.51 | 05-MAR-22:00 | 7.20 | 3.39 |
| April | 0.306621E+09 | 838.07 | 23-APR-18:00 | 25.60 | 16.47 | 80259287.52 | 70.27 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.123132E+10 | 1686.83 | 25-MAY-18:30 | 28.30 | 18.90 | 0.109667E+09 | 70.35 | 15-MAY-21:10 | 28.30 | 18.90 |
| June | 0.174857E+10 | 2060.74 | 29-JUN-18:00 | 32.80 | 24.21 | 0.118206E+09 | 70.36 | 02-JUN-21:10 | 32.80 | 24.21 |
| July | 0.206653E+10 | 1836.04 | 23-JUL-16:20 | 29.43 | 22.47 | 0.126239E+09 | 70.36 | 01-JUL-02:39 | 29.43 | 22.47 |
| August | 0.149546E+10 | 1731.47 | 08-AUG-16:15 | 30.20 | 23.02 | 0.123807E+09 | 70.34 | 24-AUG-02:49 | 15.60 | 15.19 |
| September | 0.721172E+09 | 1363.48 | 01-SEP-16:15 | 25.53 | 17.77 | 98203565.18 | 70.35 | 07-SEP-23:00 | 16.10 | 12.84 |
| October | 0.230015E+09 | 488.04 | 01-OCT-02:00 | 4.40 | 3.91 | 80413106.86 | 61.36 | 19-OCT-20:10 | 13.22 | 10.16 |
| November | 13794154.38 | 314.18 | 01-NOV-19:00 | 11.10 | 9.84 | 75558487.06 | 49.83 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 77895344.67 | 42.51 | 27-DEC-06:49 | -9.2 | -9.9 |
| Annual Sum or Average | 0.785502E+10 | 0.111642E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 70357085.41 | 42.51 | -12.8 | -13.5 | ||
| Maximum of Months | 0.206653E+10 | 2060.74 | 32.80 | 24.21 | 0.126239E+09 | 70.36 | 32.80 | 24.21 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 79846339.35 | 1093.42 | 27-JAN-12:50 | -15.9 | -16.8 | 78198344.17 | 42.51 | 03-JAN-18:00 | -15.9 | -16.8 |
| February | 0.223598E+09 | 952.83 | 10-FEB-14:00 | -12.8 | -14.1 | 70343399.44 | 68.45 | 20-FEB-16:10 | 8.62 | 2.77 |
| March | 0.392441E+09 | 1144.16 | 19-MAR-15:20 | 4.60 | 1.46 | 77913420.71 | 70.27 | 26-MAR-15:30 | 10.85 | 5.39 |
| April | 0.777413E+09 | 1983.91 | 23-APR-15:20 | 25.97 | 16.64 | 85672400.49 | 70.33 | 23-APR-23:40 | 13.53 | 9.95 |
| May | 0.166115E+10 | 2620.99 | 18-MAY-13:40 | 28.40 | 16.75 | 0.109313E+09 | 70.37 | 04-MAY-21:49 | 28.40 | 16.75 |
| June | 0.203318E+10 | 2721.13 | 30-JUN-14:10 | 31.28 | 23.89 | 0.113501E+09 | 70.36 | 07-JUN-23:19 | 31.28 | 23.89 |
| July | 0.252195E+10 | 2795.01 | 29-JUL-13:50 | 29.32 | 21.26 | 0.126549E+09 | 70.36 | 01-JUL-02:49 | 29.32 | 21.26 |
| August | 0.211341E+10 | 2620.88 | 24-AUG-14:10 | 25.18 | 17.78 | 0.119857E+09 | 70.36 | 16-AUG-23:00 | 25.18 | 17.78 |
| September | 0.134527E+10 | 2848.62 | 01-SEP-13:40 | 25.20 | 18.06 | 0.104313E+09 | 70.36 | 25-SEP-20:19 | 8.50 | 6.34 |
| October | 0.705374E+09 | 2138.40 | 22-OCT-13:40 | 19.03 | 12.89 | 85866530.76 | 70.34 | 22-OCT-20:19 | 8.13 | 6.51 |
| November | 0.178319E+09 | 737.65 | 10-NOV-16:45 | -4.0 | -6.1 | 75288024.84 | 57.51 | 01-NOV-17:00 | -4.0 | -6.1 |
| December | 44702880.43 | 1165.78 | 02-DEC-13:50 | -18.3 | -19.0 | 78198270.81 | 42.51 | 03-DEC-09:09 | -12.1 | -12.2 |
| Annual Sum or Average | 0.120766E+11 | 0.112501E+10 | ||||||||
| Minimum of Months | 44702880.43 | 737.65 | -18.3 | -19.0 | 70343399.44 | 42.51 | -15.9 | -16.8 | ||
| Maximum of Months | 0.252195E+10 | 2848.62 | 31.28 | 23.89 | 0.126549E+09 | 70.37 | 31.28 | 23.89 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 80224892.39 | 1093.66 | 27-JAN-12:50 | -15.9 | -16.8 | 78198344.17 | 42.51 | 03-JAN-18:00 | -15.9 | -16.8 |
| February | 0.223685E+09 | 963.72 | 10-FEB-14:00 | -12.8 | -14.1 | 70320319.23 | 68.22 | 20-FEB-16:10 | 8.62 | 2.77 |
| March | 0.393608E+09 | 1136.68 | 19-MAR-15:20 | 4.60 | 1.46 | 77855201.01 | 70.33 | 26-MAR-18:10 | 8.53 | 4.25 |
| April | 0.782273E+09 | 1971.82 | 23-APR-15:20 | 25.97 | 16.64 | 85632055.71 | 70.33 | 10-APR-19:10 | 25.97 | 16.64 |
| May | 0.166289E+10 | 2631.92 | 18-MAY-13:40 | 28.40 | 16.75 | 0.109256E+09 | 70.37 | 28-MAY-02:49 | 13.40 | 10.60 |
| June | 0.204154E+10 | 2722.73 | 30-JUN-14:10 | 31.28 | 23.89 | 0.113508E+09 | 70.36 | 09-JUN-17:00 | 31.28 | 23.89 |
| July | 0.252553E+10 | 2807.64 | 29-JUL-13:50 | 29.32 | 21.26 | 0.126500E+09 | 70.36 | 08-JUL-20:10 | 29.32 | 21.26 |
| August | 0.211486E+10 | 2628.29 | 24-AUG-14:10 | 25.18 | 17.78 | 0.119834E+09 | 70.36 | 04-AUG-23:19 | 25.18 | 17.78 |
| September | 0.134823E+10 | 2862.03 | 01-SEP-13:30 | 25.00 | 18.03 | 0.104245E+09 | 70.35 | 25-SEP-20:19 | 8.50 | 6.34 |
| October | 0.705966E+09 | 2150.55 | 22-OCT-13:40 | 19.03 | 12.89 | 85815664.59 | 70.34 | 01-OCT-21:10 | 19.03 | 12.89 |
| November | 0.178565E+09 | 736.75 | 10-NOV-16:45 | -4.0 | -6.1 | 75285740.51 | 57.45 | 01-NOV-17:00 | -4.0 | -6.1 |
| December | 45074401.74 | 1165.91 | 02-DEC-13:50 | -18.3 | -19.0 | 78198200.82 | 42.51 | 03-DEC-09:09 | -12.1 | -12.2 |
| Annual Sum or Average | 0.121024E+11 | 0.112465E+10 | ||||||||
| Minimum of Months | 45074401.74 | 736.75 | -18.3 | -19.0 | 70320319.23 | 42.51 | -15.9 | -16.8 | ||
| Maximum of Months | 0.252553E+10 | 2862.03 | 31.28 | 23.89 | 0.126500E+09 | 70.37 | 31.28 | 23.89 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 74893119.84 | 58.64 | 29-JAN-21:10 | -3.9 | -4.5 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 81160432.75 | 78.42 | 28-FEB-18:10 | 3.62 | -0.5 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.3 | 0.110411E+09 | 103.53 | 26-MAR-20:10 | 5.32 | 2.72 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.38 | 0.149089E+09 | 152.66 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.4 | 0.230417E+09 | 175.29 | 25-MAY-20:10 | 24.63 | 17.29 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 | 0.252475E+09 | 181.40 | 30-JUN-20:10 | 23.77 | 17.76 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.57 | 0.274770E+09 | 175.92 | 20-JUL-20:10 | 24.03 | 20.13 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 | 0.261190E+09 | 171.64 | 08-AUG-20:10 | 24.63 | 20.12 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 | 0.202284E+09 | 164.45 | 01-SEP-20:10 | 16.42 | 15.15 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 | 0.145447E+09 | 129.57 | 19-OCT-20:10 | 13.22 | 10.16 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.51 | 0.102939E+09 | 93.23 | 01-NOV-20:10 | 13.22 | 11.38 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 76768397.08 | 59.58 | 05-DEC-22:30 | 0.00 | -0.0 |
| Annual Sum or Average | 0.00 | 0.196184E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 74893119.84 | 58.64 | -3.9 | -4.5 | ||
| Maximum of Months | 0.00 | 0.00 | 19.75 | 18.15 | 0.274770E+09 | 181.40 | 24.63 | 20.13 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 22233606.75 | 47.96 | 06-JAN-07:19 | -35.0 | -35.1 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 29049700.20 | 51.47 | 23-FEB-06:10 | -7.3 | -8.5 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.3 | 44307393.18 | 60.73 | 30-MAR-04:40 | -1.5 | -1.8 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.38 | 86570775.86 | 112.35 | 23-APR-17:10 | 26.02 | 16.64 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.4 | 0.180160E+09 | 162.02 | 25-MAY-17:10 | 29.23 | 19.30 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 | 0.230476E+09 | 216.61 | 29-JUN-17:10 | 34.13 | 23.50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.57 | 0.270108E+09 | 180.24 | 29-JUL-17:10 | 29.72 | 21.17 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 | 0.253383E+09 | 171.71 | 08-AUG-17:10 | 29.22 | 22.95 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 | 0.193332E+09 | 157.35 | 01-SEP-22:10 | 13.90 | 13.22 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 | 0.113486E+09 | 113.92 | 23-OCT-05:10 | 5.60 | 4.10 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.51 | 57932926.04 | 75.54 | 02-NOV-05:10 | 5.50 | 3.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 25609016.31 | 47.69 | 06-DEC-06:10 | -0.8 | -0.8 |
| Annual Sum or Average | 0.00 | 0.150665E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 22233606.75 | 47.69 | -35.0 | -35.1 | ||
| Maximum of Months | 0.00 | 0.00 | 19.75 | 18.15 | 0.270108E+09 | 216.61 | 34.13 | 23.50 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 | 0.123070E+09 | 76.54 | 29-JAN-21:00 | -3.9 | -4.6 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 | 0.122014E+09 | 89.25 | 22-FEB-21:10 | -5.2 | -7.1 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.3 | 0.150248E+09 | 102.02 | 28-MAR-20:10 | 3.77 | 0.47 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.38 | 0.182504E+09 | 142.69 | 23-APR-20:10 | 21.32 | 14.11 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.4 | 0.259327E+09 | 163.17 | 18-MAY-20:10 | 20.55 | 13.92 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 | 0.269238E+09 | 167.16 | 30-JUN-20:10 | 23.77 | 17.76 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.57 | 0.283970E+09 | 165.29 | 24-JUL-20:10 | 21.32 | 18.93 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 | 0.276792E+09 | 160.83 | 25-AUG-20:10 | 17.80 | 16.93 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 | 0.243609E+09 | 158.87 | 01-SEP-20:10 | 16.42 | 15.15 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 | 0.185310E+09 | 134.77 | 22-OCT-20:10 | 8.22 | 6.58 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.51 | 0.140437E+09 | 94.44 | 01-NOV-21:30 | 12.25 | 11.18 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 0.122961E+09 | 76.69 | 05-DEC-22:30 | 0.00 | -0.0 |
| Annual Sum or Average | 0.00 | 0.235948E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 0.122014E+09 | 76.54 | -5.2 | -7.1 | ||
| Maximum of Months | 0.00 | 0.00 | 19.75 | 18.15 | 0.283970E+09 | 167.16 | 23.77 | 18.93 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.339400E+10 | 2540.02 | 09-JAN-08:05 | -32.6 |
| February | 0.225146E+10 | 2018.01 | 14-FEB-08:02 | -31.2 |
| March | 0.183941E+10 | 1850.90 | 06-MAR-06:50 | -19.3 |
| April | 0.643997E+09 | 1255.04 | 04-APR-07:16 | -8.1 |
| May | 21140347.88 | 480.83 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.121308E+09 | 653.92 | 30-OCT-07:10 | -9.0 |
| November | 0.107236E+10 | 1534.52 | 25-NOV-08:25 | -18.1 |
| December | 0.317566E+10 | 2514.06 | 24-DEC-08:08 | -31.1 |
| Annual Sum or Average | 0.125193E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -32.6 | |
| Maximum of Months | 0.339400E+10 | 2540.02 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.445499E+10 | 2875.52 | 04-JAN-12:00 | -28.3 |
| February | 0.328836E+10 | 2422.40 | 14-FEB-08:18 | -30.8 |
| March | 0.278548E+10 | 2195.83 | 06-MAR-08:14 | -18.5 |
| April | 0.112758E+10 | 1384.33 | 04-APR-07:16 | -8.1 |
| May | 51295582.08 | 644.40 | 01-MAY-04:00 | -2.8 |
| June | 56055.80 | 23.74 | 01-JUN-12:00 | 23.90 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.250411E+09 | 793.86 | 30-OCT-07:20 | -8.5 |
| November | 0.161958E+10 | 1618.53 | 25-NOV-08:55 | -17.8 |
| December | 0.398093E+10 | 2697.54 | 24-DEC-08:23 | -31.1 |
| Annual Sum or Average | 0.175587E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.445499E+10 | 2875.52 | 23.90 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.228453E+10 | 10424.32 | 19-JAN-07:01 | -3.3 |
| February | 0.140572E+10 | 10673.62 | 21-FEB-07:01 | 2.70 |
| March | 0.116826E+10 | 10539.33 | 28-MAR-07:01 | 1.88 |
| April | 0.306949E+09 | 10507.17 | 11-APR-07:01 | 0.93 |
| May | 0.140436E+09 | 10576.23 | 02-MAY-07:01 | 4.68 |
| June | 0.196565E+09 | 770.53 | 29-JUN-16:13 | 34.80 |
| July | 0.200924E+09 | 573.95 | 28-JUL-16:12 | 29.23 |
| August | 0.123208E+09 | 599.84 | 08-AUG-16:12 | 30.20 |
| September | 33584157.57 | 402.21 | 01-SEP-16:12 | 25.53 |
| October | 65066580.75 | 10552.40 | 16-OCT-07:01 | 5.60 |
| November | 0.622289E+09 | 10663.90 | 14-NOV-07:01 | 2.70 |
| December | 0.202588E+10 | 10519.44 | 05-DEC-07:01 | -1.1 |
| Annual Sum or Average | 0.857342E+10 | |||
| Minimum of Months | 33584157.57 | 402.21 | -3.3 | |
| Maximum of Months | 0.228453E+10 | 10673.62 | 34.80 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.444080E+10 | 2802.62 | 05-JAN-08:10 | -32.3 |
| February | 0.328671E+10 | 2313.00 | 14-FEB-08:02 | -31.2 |
| March | 0.277531E+10 | 2101.60 | 16-MAR-06:40 | -21.8 |
| April | 0.106252E+10 | 1312.62 | 05-APR-04:00 | -12.2 |
| May | 44961955.70 | 623.63 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.246790E+09 | 796.21 | 30-OCT-07:04 | -9.0 |
| November | 0.161302E+10 | 1591.33 | 25-NOV-08:30 | -18.1 |
| December | 0.396423E+10 | 2646.19 | 24-DEC-08:10 | -31.1 |
| Annual Sum or Average | 0.174344E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -32.3 | |
| Maximum of Months | 0.444080E+10 | 2802.62 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.269377E+10 | 1829.48 | 05-JAN-08:16 | -32.4 |
| February | 0.193612E+10 | 1551.91 | 14-FEB-08:18 | -30.8 |
| March | 0.159688E+10 | 1369.32 | 15-MAR-07:27 | -23.4 |
| April | 0.487036E+09 | 761.15 | 04-APR-07:16 | -8.1 |
| May | 14209523.24 | 275.71 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 25409230.74 | 318.50 | 30-OCT-07:14 | -8.5 |
| November | 0.706579E+09 | 925.70 | 25-NOV-08:25 | -18.1 |
| December | 0.233051E+10 | 1698.73 | 24-DEC-08:27 | -31.1 |
| Annual Sum or Average | 0.979052E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -32.4 | |
| Maximum of Months | 0.269377E+10 | 1829.48 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.269335E+10 | 1829.41 | 05-JAN-08:16 | -32.4 |
| February | 0.193651E+10 | 1551.64 | 14-FEB-08:18 | -30.8 |
| March | 0.159672E+10 | 1367.36 | 15-MAR-07:20 | -23.5 |
| April | 0.485214E+09 | 758.43 | 04-APR-07:16 | -8.1 |
| May | 14000403.63 | 273.81 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 25329829.31 | 319.38 | 30-OCT-07:13 | -8.5 |
| November | 0.706286E+09 | 925.25 | 25-NOV-08:25 | -18.1 |
| December | 0.233003E+10 | 1698.56 | 24-DEC-08:27 | -31.1 |
| Annual Sum or Average | 0.978744E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -32.4 | |
| Maximum of Months | 0.269335E+10 | 1829.41 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.165784E+10 | 1566.73 | 09-JAN-08:05 | -32.6 |
| February | 0.984070E+09 | 1198.37 | 17-FEB-08:23 | -27.8 |
| March | 0.745805E+09 | 1008.73 | 05-MAR-04:00 | -28.3 |
| April | 0.174795E+09 | 621.61 | 04-APR-07:16 | -8.1 |
| May | 2514966.89 | 115.93 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 2081226.61 | 169.40 | 30-OCT-07:10 | -9.0 |
| November | 0.338223E+09 | 848.71 | 25-NOV-08:25 | -18.1 |
| December | 0.155082E+10 | 1526.39 | 24-DEC-08:08 | -31.1 |
| Annual Sum or Average | 0.545614E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -32.6 | |
| Maximum of Months | 0.165784E+10 | 1566.73 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.200260E+10 | 1756.13 | 09-JAN-08:05 | -32.6 |
| February | 0.122962E+10 | 1322.28 | 17-FEB-08:23 | -27.8 |
| March | 0.966387E+09 | 1185.53 | 06-MAR-06:50 | -19.3 |
| April | 0.247691E+09 | 744.91 | 04-APR-07:16 | -8.1 |
| May | 5245445.74 | 202.48 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 5440153.58 | 220.99 | 30-OCT-07:09 | -9.0 |
| November | 0.485457E+09 | 997.18 | 25-NOV-08:25 | -18.1 |
| December | 0.187425E+10 | 1705.36 | 24-DEC-08:06 | -31.1 |
| Annual Sum or Average | 0.681669E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -32.6 | |
| Maximum of Months | 0.200260E+10 | 1756.13 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.236292E+10 | 2456.75 | 04-JAN-06:00 | -28.9 |
| February | 0.137047E+10 | 1960.92 | 12-FEB-23:00 | -17.2 |
| March | 0.706885E+09 | 1408.93 | 06-MAR-06:50 | -19.3 |
| April | 0.149624E+09 | 718.14 | 04-APR-04:00 | -7.2 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 96141163.61 | 615.58 | 30-OCT-07:04 | -9.0 |
| November | 0.830911E+09 | 1537.61 | 25-NOV-02:00 | -15.6 |
| December | 0.242917E+10 | 2175.39 | 24-DEC-08:08 | -31.1 |
| Annual Sum or Average | 0.794611E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.242917E+10 | 2456.75 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.335794E+10 | 2796.55 | 04-JAN-12:00 | -28.3 |
| February | 0.221863E+10 | 2164.50 | 12-FEB-23:00 | -17.2 |
| March | 0.129281E+10 | 1699.24 | 15-MAR-05:00 | -22.2 |
| April | 0.281440E+09 | 790.79 | 02-APR-04:00 | -5.6 |
| May | 36758.51 | 30.17 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.181042E+09 | 705.29 | 30-OCT-09:00 | -3.3 |
| November | 0.125921E+10 | 1569.28 | 25-NOV-02:00 | -15.6 |
| December | 0.320527E+10 | 2415.64 | 24-DEC-09:20 | -30.7 |
| Annual Sum or Average | 0.117964E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -30.7 | |
| Maximum of Months | 0.335794E+10 | 2796.55 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.234043E+10 | 2450.16 | 04-JAN-06:00 | -28.9 |
| February | 0.135161E+10 | 1971.44 | 12-FEB-23:00 | -17.2 |
| March | 0.690615E+09 | 1399.58 | 15-MAR-05:00 | -22.2 |
| April | 0.141727E+09 | 727.58 | 04-APR-04:00 | -7.2 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 91118328.78 | 622.09 | 30-OCT-07:03 | -9.0 |
| November | 0.827315E+09 | 1531.23 | 25-NOV-02:00 | -15.6 |
| December | 0.240874E+10 | 2168.57 | 24-DEC-08:08 | -31.1 |
| Annual Sum or Average | 0.785155E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.240874E+10 | 2450.16 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.334248E+10 | 2642.84 | 04-JAN-06:00 | -28.9 |
| February | 0.220872E+10 | 2177.68 | 12-FEB-23:00 | -17.2 |
| March | 0.126397E+10 | 1708.90 | 15-MAR-05:00 | -22.2 |
| April | 0.261096E+09 | 814.21 | 02-APR-04:00 | -5.6 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.175274E+09 | 698.35 | 30-OCT-07:00 | -9.4 |
| November | 0.125019E+10 | 1563.02 | 25-NOV-02:00 | -15.6 |
| December | 0.318586E+10 | 2287.71 | 24-DEC-08:02 | -31.1 |
| Annual Sum or Average | 0.116876E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.334248E+10 | 2642.84 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.154996E+10 | 1496.08 | 04-JAN-12:00 | -28.3 |
| February | 0.936038E+09 | 1105.55 | 01-FEB-06:00 | -22.8 |
| March | 0.430337E+09 | 856.51 | 15-MAR-05:00 | -22.2 |
| April | 39669597.37 | 297.42 | 02-APR-04:00 | -5.6 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 5756305.78 | 185.63 | 30-OCT-09:00 | -3.3 |
| November | 0.351879E+09 | 744.11 | 25-NOV-02:00 | -15.6 |
| December | 0.142983E+10 | 1257.10 | 24-DEC-09:50 | -30.0 |
| Annual Sum or Average | 0.474347E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -30.0 | |
| Maximum of Months | 0.154996E+10 | 1496.08 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.154956E+10 | 1492.34 | 04-JAN-12:00 | -28.3 |
| February | 0.935961E+09 | 1107.01 | 01-FEB-06:00 | -22.8 |
| March | 0.430191E+09 | 856.94 | 15-MAR-05:00 | -22.2 |
| April | 39596564.95 | 299.61 | 02-APR-04:00 | -5.6 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 5639163.73 | 182.28 | 30-OCT-09:00 | -3.3 |
| November | 0.351738E+09 | 743.94 | 25-NOV-02:00 | -15.6 |
| December | 0.142929E+10 | 1252.67 | 24-DEC-09:40 | -30.2 |
| Annual Sum or Average | 0.474197E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -30.2 | |
| Maximum of Months | 0.154956E+10 | 1492.34 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.750607E+09 | 1190.98 | 04-JAN-06:00 | -28.9 |
| February | 0.386892E+09 | 917.36 | 13-FEB-04:00 | -22.8 |
| March | 0.136029E+09 | 598.58 | 15-MAR-05:00 | -22.2 |
| April | 6937260.44 | 228.75 | 04-APR-04:00 | -7.2 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 835532.56 | 101.47 | 30-OCT-07:09 | -9.0 |
| November | 0.165461E+09 | 705.47 | 25-NOV-02:00 | -15.6 |
| December | 0.779169E+09 | 1070.09 | 16-DEC-06:00 | -15.6 |
| Annual Sum or Average | 0.222593E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -28.9 | |
| Maximum of Months | 0.779169E+09 | 1190.98 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.750592E+09 | 1190.77 | 04-JAN-06:00 | -28.9 |
| February | 0.387214E+09 | 918.19 | 13-FEB-04:00 | -22.8 |
| March | 0.136450E+09 | 599.04 | 15-MAR-05:00 | -22.2 |
| April | 7098572.27 | 230.02 | 04-APR-04:00 | -7.2 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 836231.68 | 101.99 | 30-OCT-07:09 | -9.0 |
| November | 0.165560E+09 | 705.30 | 25-NOV-02:00 | -15.6 |
| December | 0.779010E+09 | 1069.91 | 16-DEC-06:00 | -15.6 |
| Annual Sum or Average | 0.222676E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -28.9 | |
| Maximum of Months | 0.779010E+09 | 1190.77 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.518893E+10 | 4380.26 | 04-JAN-06:00 | -28.9 |
| February | 0.346560E+10 | 3681.85 | 13-FEB-04:00 | -22.8 |
| March | 0.240673E+10 | 3040.90 | 15-MAR-05:00 | -22.2 |
| April | 0.947856E+09 | 1791.32 | 04-APR-04:00 | -7.2 |
| May | 52986421.54 | 623.25 | 01-MAY-04:00 | -2.8 |
| June | 202579.36 | 65.82 | 04-JUN-05:00 | 1.10 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 789825.94 | 190.52 | 19-AUG-06:00 | 5.60 |
| September | 71329048.52 | 513.67 | 28-SEP-02:00 | 7.20 |
| October | 0.831856E+09 | 1805.66 | 30-OCT-07:03 | -9.0 |
| November | 0.245789E+10 | 2821.02 | 25-NOV-02:00 | -15.6 |
| December | 0.516830E+10 | 3969.48 | 24-DEC-08:05 | -31.1 |
| Annual Sum or Average | 0.205925E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.518893E+10 | 4380.26 | 15.83 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.627555E+10 | 4476.03 | 04-JAN-12:00 | -28.3 |
| February | 0.446233E+10 | 3761.59 | 13-FEB-04:00 | -22.8 |
| March | 0.315424E+10 | 3220.52 | 15-MAR-05:00 | -22.2 |
| April | 0.122619E+10 | 1875.53 | 05-APR-04:00 | -12.2 |
| May | 65619675.39 | 787.48 | 01-MAY-04:00 | -2.8 |
| June | 57154.69 | 34.11 | 04-JUN-04:20 | 2.23 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 1092440.41 | 217.06 | 19-AUG-07:13 | 10.33 |
| September | 94348149.29 | 536.42 | 28-SEP-02:00 | 7.20 |
| October | 0.105734E+10 | 1810.51 | 30-OCT-07:05 | -9.0 |
| November | 0.302981E+10 | 2846.85 | 25-NOV-02:00 | -15.6 |
| December | 0.600959E+10 | 4202.96 | 24-DEC-09:00 | -31.1 |
| Annual Sum or Average | 0.253762E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.627555E+10 | 4476.03 | 15.83 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.515719E+10 | 4366.34 | 04-JAN-06:00 | -28.9 |
| February | 0.342982E+10 | 3674.42 | 13-FEB-04:00 | -22.8 |
| March | 0.236533E+10 | 3047.14 | 15-MAR-05:00 | -22.2 |
| April | 0.901058E+09 | 1791.52 | 04-APR-04:00 | -7.2 |
| May | 49980036.62 | 621.84 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 330140.22 | 119.76 | 19-AUG-05:30 | 5.00 |
| September | 73353944.94 | 561.27 | 28-SEP-17:01 | 9.32 |
| October | 0.829546E+09 | 1812.05 | 30-OCT-07:09 | -9.0 |
| November | 0.244460E+10 | 2809.09 | 25-NOV-02:00 | -15.6 |
| December | 0.514080E+10 | 3952.51 | 24-DEC-08:07 | -31.1 |
| Annual Sum or Average | 0.203920E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.515719E+10 | 4366.34 | 15.83 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.625481E+10 | 4455.73 | 04-JAN-06:00 | -28.9 |
| February | 0.444673E+10 | 3752.59 | 13-FEB-04:00 | -22.8 |
| March | 0.309436E+10 | 3227.78 | 15-MAR-05:00 | -22.2 |
| April | 0.114462E+10 | 1931.40 | 05-APR-04:00 | -12.2 |
| May | 66592234.57 | 794.29 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 569083.60 | 149.46 | 19-AUG-05:30 | 5.00 |
| September | 96144129.63 | 599.83 | 28-SEP-17:01 | 9.32 |
| October | 0.104828E+10 | 1816.85 | 30-OCT-07:04 | -9.0 |
| November | 0.301755E+10 | 2835.31 | 25-NOV-02:00 | -15.6 |
| December | 0.598292E+10 | 4045.91 | 24-DEC-08:02 | -31.1 |
| Annual Sum or Average | 0.251526E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.625481E+10 | 4455.73 | 15.83 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.400185E+10 | 2874.12 | 04-JAN-06:00 | -28.9 |
| February | 0.278582E+10 | 2398.69 | 14-FEB-05:00 | -32.2 |
| March | 0.187800E+10 | 2068.21 | 15-MAR-05:00 | -22.2 |
| April | 0.597315E+09 | 1214.35 | 05-APR-04:00 | -12.2 |
| May | 15125680.00 | 386.35 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 10480917.20 | 190.62 | 28-SEP-02:00 | 7.20 |
| October | 0.445779E+09 | 1094.14 | 30-OCT-07:16 | -8.5 |
| November | 0.170344E+10 | 1787.61 | 25-NOV-02:00 | -15.6 |
| December | 0.377681E+10 | 2716.13 | 24-DEC-08:55 | -31.1 |
| Annual Sum or Average | 0.152146E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -32.2 | |
| Maximum of Months | 0.400185E+10 | 2874.12 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.400144E+10 | 2874.01 | 04-JAN-06:00 | -28.9 |
| February | 0.278626E+10 | 2400.35 | 14-FEB-05:00 | -32.2 |
| March | 0.187785E+10 | 2069.14 | 15-MAR-05:00 | -22.2 |
| April | 0.596125E+09 | 1218.52 | 05-APR-04:00 | -12.2 |
| May | 15445429.52 | 384.25 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 10826269.68 | 193.14 | 28-SEP-02:00 | 7.20 |
| October | 0.446532E+09 | 1094.22 | 30-OCT-07:17 | -8.5 |
| November | 0.170315E+10 | 1787.16 | 25-NOV-02:00 | -15.6 |
| December | 0.377607E+10 | 2711.41 | 24-DEC-08:55 | -31.1 |
| Annual Sum or Average | 0.152137E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -32.2 | |
| Maximum of Months | 0.400144E+10 | 2874.01 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.296678E+10 | 2778.04 | 04-JAN-06:00 | -28.9 |
| February | 0.189190E+10 | 2291.24 | 13-FEB-04:00 | -22.8 |
| March | 0.123481E+10 | 1877.70 | 15-MAR-05:00 | -22.2 |
| April | 0.394151E+09 | 1064.28 | 04-APR-04:00 | -7.2 |
| May | 7305934.20 | 218.28 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 5482310.83 | 158.44 | 28-SEP-02:70 | 7.20 |
| October | 0.316305E+09 | 1085.87 | 30-OCT-07:04 | -9.0 |
| November | 0.122151E+10 | 1762.01 | 25-NOV-06:00 | -19.4 |
| December | 0.296798E+10 | 2527.04 | 24-DEC-08:07 | -31.1 |
| Annual Sum or Average | 0.110062E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.296798E+10 | 2778.04 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.296676E+10 | 2777.95 | 04-JAN-06:00 | -28.9 |
| February | 0.189280E+10 | 2291.82 | 13-FEB-04:00 | -22.8 |
| March | 0.123637E+10 | 1878.67 | 15-MAR-05:00 | -22.2 |
| April | 0.393951E+09 | 1064.79 | 04-APR-04:00 | -7.2 |
| May | 7306293.82 | 214.41 | 01-MAY-04:00 | -2.8 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 5644149.18 | 160.91 | 28-SEP-02:70 | 7.20 |
| October | 0.316956E+09 | 1086.10 | 30-OCT-07:04 | -9.0 |
| November | 0.122177E+10 | 1761.74 | 25-NOV-06:00 | -19.4 |
| December | 0.296759E+10 | 2526.75 | 24-DEC-08:07 | -31.1 |
| Annual Sum or Average | 0.110091E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -31.1 | |
| Maximum of Months | 0.296759E+10 | 2777.95 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -23.1 | |
| Maximum of Months | 0.00 | 0.00 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -23.1 | |
| Maximum of Months | 0.00 | 0.00 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | -23.1 | |
| Maximum of Months | 0.00 | 0.00 | 19.75 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.878160E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.763058E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.565980E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 587125.91 | 0.448205E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3451796.91 | 0.186928E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13250008.26 | 0.103176E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13873947.15 | 67228639.70 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5407343.84 | 0.110037E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 169671.63 | 0.216531E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325772E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.583302E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.881893E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 36739893.70 | 0.513027E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67228639.70 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13873947.15 | 0.881893E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.878160E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.763039E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.565759E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 920772.16 | 0.442135E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3670738.92 | 0.179636E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13251024.37 | 0.101740E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13873949.48 | 67131953.55 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5407344.91 | 0.109394E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 169671.46 | 0.206892E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.315923E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.583045E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.881893E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37293501.30 | 0.509475E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67131953.55 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13873949.48 | 0.881893E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.781566E+09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.675256E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.501587E+09 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 289946.79 | 0.407993E+09 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2430491.27 | 0.201454E+09 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8381806.47 | 0.128552E+09 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6461202.18 | 98596869.21 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3627260.06 | 0.146010E+09 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 140879.54 | 0.242576E+09 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.316742E+09 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.512630E+09 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.780142E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21331586.31 | 0.479310E+10 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98596869.21 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8381806.47 | 0.781566E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.878160E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.763039E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.565759E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1121960.44 | 0.441933E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3658094.37 | 0.178917E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13250019.11 | 0.103187E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13873959.47 | 67016842.04 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5407349.05 | 0.109647E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 169671.68 | 0.207722E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.315700E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.583046E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.881893E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37481054.12 | 0.509602E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67016842.04 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13873959.47 | 0.881893E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529684E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.460246E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341252E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 702833.96 | 0.266461E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2260949.02 | 0.109449E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7992077.86 | 63266545.58 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368422.70 | 40591116.94 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3261577.37 | 66660926.10 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 102341.74 | 0.127940E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.190882E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.351717E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531936E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 22688202.65 | 0.308008E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40591116.94 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368422.70 | 0.531936E+09 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529684E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.460246E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341252E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 706885.26 | 0.266458E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2260601.38 | 0.109409E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7992077.86 | 63350414.40 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368422.82 | 40588052.37 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3261577.41 | 66667436.09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 102341.74 | 0.127975E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.190870E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.351717E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531936E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 22691906.47 | 0.308015E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40588052.37 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368422.82 | 0.531936E+09 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529684E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.460315E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341398E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 354140.34 | 0.271264E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2087687.81 | 0.114823E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7992074.54 | 64018108.59 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368420.54 | 40622610.07 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3261576.57 | 66864933.56 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 102341.82 | 0.133560E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198697E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352096E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531936E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 22166241.63 | 0.310528E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40622610.07 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368420.54 | 0.531936E+09 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529684E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.460269E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.341337E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 354140.37 | 0.271093E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2076474.83 | 0.115202E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7992074.83 | 64368275.93 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368421.36 | 40632146.43 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3261576.90 | 66925646.95 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 102341.85 | 0.134003E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198861E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352015E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531936E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 22155030.15 | 0.310633E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40632146.43 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8368421.36 | 0.531936E+09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126267E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110015E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.819700E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 833312.24 | 0.672346E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4798470.97 | 0.296320E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18937184.01 | 0.156665E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800139.98 | 97153681.26 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7699563.04 | 0.159191E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 239826.90 | 0.315273E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.473934E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.840813E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126807E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 52308497.13 | 0.746228E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97153681.26 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800139.98 | 0.126807E+10 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126267E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109725E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.814301E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 833313.79 | 0.651584E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4798483.68 | 0.292377E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18937186.49 | 0.156569E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800138.67 | 97148674.92 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7699561.98 | 0.158910E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 239826.41 | 0.306812E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.459907E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.838788E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126807E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 52308511.02 | 0.740438E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97148674.92 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800138.67 | 0.126807E+10 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126267E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109960E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.819149E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 833313.24 | 0.675214E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4798479.35 | 0.296952E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18937201.55 | 0.156672E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800163.97 | 97127576.71 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7699574.39 | 0.159315E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 239827.46 | 0.315353E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.473559E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.840802E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126807E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 52308559.96 | 0.746448E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97127576.71 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800163.97 | 0.126807E+10 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126267E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109725E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.813698E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 833316.01 | 0.652274E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4798489.15 | 0.293662E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18937202.07 | 0.156549E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800159.64 | 97102832.44 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7699570.56 | 0.159116E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 239826.83 | 0.307870E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.459404E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.838787E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126807E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 52308564.26 | 0.740645E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97102832.44 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800159.64 | 0.126807E+10 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761611E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.661832E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.490877E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 502988.14 | 0.392419E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2894331.12 | 0.178192E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11422441.45 | 94884807.09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.13 | 58628957.87 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4644188.04 | 96460642.12 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 144657.60 | 0.190126E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279015E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.506085E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.764867E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31551562.49 | 0.447500E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58628957.87 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.13 | 0.764867E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761611E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.661832E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.490865E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 502926.05 | 0.392507E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2894331.13 | 0.178259E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11422441.60 | 94884494.30 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.36 | 58628178.86 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4644188.12 | 96466459.27 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 144657.61 | 0.190145E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278973E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.506086E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.764867E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31551500.87 | 0.447512E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58628178.86 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.36 | 0.764867E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761611E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.664812E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.495317E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 502633.76 | 0.410218E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2894323.36 | 0.180904E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11422439.39 | 94903452.44 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.16 | 58628881.30 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4644188.52 | 96523305.40 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 144657.86 | 0.194283E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.290442E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508774E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.764868E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31551199.06 | 0.452129E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58628881.30 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.16 | 0.764868E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761611E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.664805E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.495312E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 502633.78 | 0.410340E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2894323.46 | 0.180921E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11422439.54 | 94903659.09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.47 | 58628607.94 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4644188.67 | 96525905.70 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 144657.87 | 0.194256E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.290406E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508789E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.764868E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31551199.79 | 0.452137E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58628607.94 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942956.47 | 0.764868E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167207E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145825E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108635E+10 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1074706.89 | 0.877814E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6224792.72 | 0.367075E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24776655.65 | 0.194692E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828743.19 | 0.124655E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9997729.14 | 0.198990E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 306648.84 | 0.384234E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.615722E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111424E+10 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167930E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 68209276.44 | 0.977339E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124655E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828743.19 | 0.167930E+10 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167207E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145329E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107912E+10 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1074706.88 | 0.859590E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6224802.39 | 0.361077E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24776650.66 | 0.194914E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828729.44 | 0.124790E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9997719.56 | 0.197404E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 306647.29 | 0.370947E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604818E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111143E+10 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167930E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 68209256.20 | 0.970875E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124790E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828729.44 | 0.167930E+10 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167207E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145718E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108578E+10 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1074708.71 | 0.881467E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6224810.96 | 0.369122E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24776693.29 | 0.196745E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828795.59 | 0.125103E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9997754.10 | 0.200162E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 306650.08 | 0.386088E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.615760E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111419E+10 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167930E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 68209412.73 | 0.978296E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125103E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828795.59 | 0.167930E+10 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167207E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145329E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107800E+10 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1074709.80 | 0.860269E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6224815.34 | 0.364321E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24776684.73 | 0.196775E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828774.47 | 0.124858E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9997738.44 | 0.199076E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 306648.17 | 0.375463E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604174E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111142E+10 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167930E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 68209370.94 | 0.971901E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124858E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25828774.47 | 0.167930E+10 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100855E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.876590E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.650264E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 648238.32 | 0.516206E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3754656.74 | 0.220382E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14944663.83 | 0.120689E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579256.55 | 76411055.56 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6030382.34 | 0.122732E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 184962.44 | 0.227640E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.364305E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.670458E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101291E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 41142160.22 | 0.586714E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76411055.56 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579256.55 | 0.101291E+10 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100855E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.876590E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.650243E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 648238.37 | 0.516356E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3754656.83 | 0.220585E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14944664.47 | 0.120759E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579257.44 | 76387615.76 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6030382.69 | 0.122778E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 184962.46 | 0.227918E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.364308E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.670458E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101291E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 41142162.26 | 0.586785E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76387615.76 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579257.44 | 0.101291E+10 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100855E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.880670E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.655900E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 648237.27 | 0.532337E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3754649.34 | 0.224977E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14944666.63 | 0.120593E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579265.35 | 76400235.96 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6030388.74 | 0.123553E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 184963.39 | 0.237374E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373435E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.673437E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101291E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 41142170.71 | 0.592014E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76400235.96 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579265.35 | 0.101291E+10 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100855E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.880645E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.655899E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 648237.31 | 0.532519E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3754649.71 | 0.225043E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14944667.42 | 0.120649E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579266.45 | 76392149.70 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6030389.31 | 0.123570E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 184963.42 | 0.237393E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373406E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.673459E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101291E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 41142173.62 | 0.592044E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76392149.70 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15579266.45 | 0.101291E+10 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273992E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241488E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182695E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26746.13 | 0.153321E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 160464.43 | 72106982.87 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1682718.25 | 44095758.58 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1227620.27 | 30571704.11 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 360668.40 | 44720377.10 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74158149.28 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107248E+09 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186240E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274972E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3458217.48 | 0.168561E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30571704.11 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1682718.25 | 0.274972E+09 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.795350E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.596938E+10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540634E+10 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6437481.37 | 0.322538E+10 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28542909.45 | 0.181540E+10 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59305028.14 | 0.115706E+10 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47001383.83 | 0.101053E+10 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12475796.24 | 0.134754E+10 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220809E+10 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.328147E+10 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450344E+10 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.748561E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153763E+09 | 0.453637E+11 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101053E+10 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59305028.14 | 0.795350E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.218500E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192595E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145785E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49021.53 | 0.123792E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 210489.42 | 59436263.79 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1582873.87 | 35482938.87 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1282215.76 | 23881189.66 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 368570.60 | 35895329.71 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62997555.75 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87685099.91 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149780E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219404E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3493171.18 | 0.135523E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23881189.66 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1582873.87 | 0.219404E+09 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1095.25 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1175.08 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 597.29 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.22 | 23-APR-16:00 | 546.39 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.04 | 24-MAY-15:00 | 228.84 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.28 | 29-JUN-16:00 | 268.03 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.86 | 15-JUL-15:00 | 157.49 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.65 | 08-AUG-16:00 | 333.71 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.46 | 01-SEP-15:00 | 263.78 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 411.89 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 653.02 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1000.89 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 157.49 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 146.28 | 1175.08 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1095.25 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1175.08 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 597.29 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.46 | 23-APR-16:00 | 546.39 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.04 | 24-MAY-15:00 | 223.98 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.28 | 29-JUN-16:00 | 264.05 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.86 | 15-JUL-15:00 | 158.13 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.65 | 08-AUG-16:00 | 330.02 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.46 | 01-SEP-15:00 | 259.71 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 411.89 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 653.02 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1000.89 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 158.13 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 146.28 | 1175.08 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1095.25 | 04-JAN-12:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1006.34 | 12-FEB-23:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 597.29 | 14-MAR-15:00 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.81 | 23-APR-16:00 | 557.91 | 19-APR-10:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.03 | 24-MAY-15:00 | 238.37 | 20-MAY-06:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.27 | 29-JUN-16:00 | 287.12 | 09-JUN-09:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.31 | 28-JUL-15:00 | 181.18 | 06-JUL-22:00 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.63 | 08-AUG-16:00 | 354.51 | 17-AUG-14:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.45 | 01-SEP-15:00 | 274.74 | 20-SEP-01:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 411.89 | 31-OCT-11:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 543.57 | 22-NOV-02:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1000.89 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.18 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 146.27 | 1095.25 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1095.25 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1175.08 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 597.29 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.62 | 23-APR-16:00 | 546.39 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.04 | 24-MAY-15:00 | 223.23 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.28 | 29-JUN-16:00 | 264.02 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.86 | 15-JUL-15:00 | 158.04 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.65 | 08-AUG-16:00 | 331.40 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.46 | 01-SEP-15:00 | 259.07 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 411.89 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 653.02 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1000.89 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 158.04 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 146.28 | 1175.08 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 660.62 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 708.78 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 360.27 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.60 | 23-APR-16:00 | 329.57 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.56 | 24-MAY-15:00 | 139.33 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 29-JUN-16:00 | 164.40 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.31 | 15-JUL-15:00 | 96.07 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.30 | 08-AUG-16:00 | 206.84 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.32 | 01-SEP-15:00 | 162.61 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 248.44 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 393.89 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 603.71 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.07 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 708.78 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 660.62 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 708.78 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 360.27 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.81 | 23-APR-16:00 | 329.57 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.56 | 24-MAY-15:00 | 139.25 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 29-JUN-16:00 | 164.57 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.31 | 15-JUL-15:00 | 96.07 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.30 | 08-AUG-16:00 | 206.89 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.32 | 01-SEP-15:00 | 162.58 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 248.44 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 393.89 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 603.71 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.07 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 708.78 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 660.62 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 708.78 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 360.27 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.93 | 23-APR-16:00 | 329.57 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.56 | 24-MAY-15:00 | 142.92 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 29-JUN-16:00 | 167.01 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.31 | 15-JUL-15:00 | 95.72 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.30 | 08-AUG-16:00 | 208.85 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.32 | 01-SEP-15:00 | 164.69 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 248.44 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 393.89 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 603.71 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 708.78 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 660.62 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 708.78 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 360.27 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.93 | 23-APR-16:00 | 329.57 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.56 | 24-MAY-15:00 | 143.50 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 29-JUN-16:00 | 168.34 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.31 | 15-JUL-15:00 | 96.01 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.30 | 08-AUG-16:00 | 210.33 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.32 | 01-SEP-15:00 | 165.21 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 248.44 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 393.89 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 603.71 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.23 | 708.78 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1574.60 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1689.57 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 858.91 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.34 | 23-APR-16:00 | 823.49 | 19-APR-10:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 62.95 | 24-MAY-15:00 | 342.04 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 29-JUN-16:00 | 402.85 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.94 | 15-JUL-15:00 | 226.87 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.48 | 08-AUG-16:00 | 484.02 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.01 | 01-SEP-15:00 | 382.00 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 592.53 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 939.26 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1439.01 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.87 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 1689.57 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1574.60 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1689.57 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 858.91 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.34 | 23-APR-16:00 | 785.92 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 62.95 | 24-MAY-15:00 | 341.12 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 29-JUN-16:00 | 401.40 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.94 | 15-JUL-15:00 | 229.24 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.48 | 08-AUG-16:00 | 482.03 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.01 | 01-SEP-15:00 | 379.95 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 592.53 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 939.26 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1439.01 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 229.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 1689.57 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1574.60 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1689.57 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 858.91 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.34 | 23-APR-16:00 | 876.82 | 19-APR-10:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 62.95 | 24-MAY-15:00 | 342.09 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 29-JUN-16:00 | 400.55 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.94 | 15-JUL-15:00 | 226.73 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.48 | 08-AUG-16:00 | 485.31 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.01 | 01-SEP-15:00 | 381.76 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 592.53 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 939.26 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1439.01 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.73 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 1689.57 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1574.60 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1689.57 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 858.91 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.34 | 23-APR-16:00 | 804.07 | 19-APR-10:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 62.95 | 24-MAY-15:00 | 341.14 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 29-JUN-16:00 | 399.03 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.94 | 15-JUL-15:00 | 229.10 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.48 | 08-AUG-16:00 | 483.58 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.01 | 01-SEP-15:00 | 379.61 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 592.53 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 939.26 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1439.01 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 229.10 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 209.84 | 1689.57 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 949.76 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1019.11 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 518.07 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.68 | 23-APR-16:00 | 474.05 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.97 | 24-MAY-15:00 | 211.54 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 29-JUN-16:00 | 247.43 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.93 | 15-JUL-15:00 | 138.46 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.52 | 08-AUG-16:00 | 301.42 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.27 | 01-SEP-15:00 | 237.88 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 357.40 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 566.54 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 867.98 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.46 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 1019.11 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 949.76 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1019.11 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 518.07 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.68 | 23-APR-16:00 | 474.05 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.97 | 24-MAY-15:00 | 211.51 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 29-JUN-16:00 | 247.35 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.93 | 15-JUL-15:00 | 138.46 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.52 | 08-AUG-16:00 | 301.50 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.27 | 01-SEP-15:00 | 237.84 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 357.40 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 566.54 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 867.98 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.46 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 1019.11 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 949.76 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1019.11 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 518.07 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.68 | 23-APR-16:00 | 519.09 | 19-APR-10:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.97 | 24-MAY-15:00 | 212.16 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 29-JUN-16:00 | 248.38 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.93 | 15-JUL-15:00 | 137.34 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.52 | 08-AUG-16:00 | 302.39 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.27 | 01-SEP-15:00 | 238.95 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 357.40 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 566.54 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 867.98 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.34 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 1019.11 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 949.76 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1019.11 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 518.07 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.68 | 23-APR-16:00 | 520.52 | 19-APR-10:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.97 | 24-MAY-15:00 | 212.14 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 29-JUN-16:00 | 248.30 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.93 | 15-JUL-15:00 | 137.33 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.52 | 08-AUG-16:00 | 302.46 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.27 | 01-SEP-15:00 | 238.92 | 20-SEP-01:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 357.40 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 566.54 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 867.98 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.33 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 126.57 | 1019.11 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2084.59 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2237.30 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1137.62 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.82 | 23-APR-16:00 | 1041.51 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.40 | 24-MAY-15:00 | 405.38 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 29-JUN-16:00 | 459.96 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 235.37 | 15-JUL-15:00 | 276.95 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.07 | 08-AUG-16:00 | 548.14 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.56 | 01-SEP-15:00 | 464.67 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 785.45 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1244.62 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1905.27 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 276.95 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 2237.30 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2084.59 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2237.30 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1137.62 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.82 | 23-APR-16:00 | 1041.51 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.40 | 24-MAY-15:00 | 405.38 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 29-JUN-16:00 | 459.40 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 235.37 | 15-JUL-15:00 | 286.76 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.07 | 08-AUG-16:00 | 547.63 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.56 | 01-SEP-15:00 | 464.67 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 785.45 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1244.62 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1905.27 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 286.76 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 2237.30 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2084.59 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2237.30 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1137.62 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.82 | 23-APR-16:00 | 1079.64 | 19-APR-10:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.40 | 24-MAY-15:00 | 405.38 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 29-JUN-16:00 | 454.92 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 235.37 | 15-JUL-15:00 | 276.47 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.07 | 08-AUG-16:00 | 550.19 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.56 | 01-SEP-15:00 | 464.67 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 785.45 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1244.62 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1905.27 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 276.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 2237.30 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2084.59 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2237.30 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1137.62 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.82 | 23-APR-16:00 | 1041.51 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.40 | 24-MAY-15:00 | 405.38 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 29-JUN-16:00 | 454.12 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 235.37 | 15-JUL-15:00 | 286.24 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.07 | 08-AUG-16:00 | 550.14 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.56 | 01-SEP-15:00 | 464.67 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 785.45 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1244.62 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1905.27 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 286.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 276.57 | 2237.30 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1257.37 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1349.48 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 686.18 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.65 | 23-APR-16:00 | 628.21 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.70 | 24-MAY-15:00 | 248.09 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 29-JUN-16:00 | 295.49 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.97 | 15-JUL-15:00 | 176.51 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.82 | 08-AUG-16:00 | 356.97 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.22 | 01-SEP-15:00 | 280.27 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 473.76 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 750.72 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1149.21 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.51 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 1349.48 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1257.37 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1349.48 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 686.18 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.65 | 23-APR-16:00 | 628.21 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.70 | 24-MAY-15:00 | 248.06 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 29-JUN-16:00 | 295.05 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.97 | 15-JUL-15:00 | 176.50 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.82 | 08-AUG-16:00 | 357.24 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.22 | 01-SEP-15:00 | 280.27 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 473.76 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 750.72 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1149.21 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.50 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 1349.48 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1257.37 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1349.48 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 686.18 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.65 | 23-APR-16:00 | 628.21 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.70 | 24-MAY-15:00 | 248.61 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 29-JUN-16:00 | 296.06 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.97 | 15-JUL-15:00 | 170.30 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.82 | 08-AUG-16:00 | 357.32 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.22 | 01-SEP-15:00 | 280.27 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 473.76 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 750.72 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1149.21 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.30 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 1349.48 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1257.37 | 04-JAN-12:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1349.48 | 12-FEB-23:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 686.18 | 14-MAR-15:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.65 | 23-APR-16:00 | 628.21 | 26-APR-15:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.70 | 24-MAY-15:00 | 248.58 | 20-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 29-JUN-16:00 | 295.64 | 09-JUN-09:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.97 | 15-JUL-15:00 | 170.29 | 03-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.82 | 08-AUG-16:00 | 357.52 | 17-AUG-14:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.22 | 01-SEP-15:00 | 280.27 | 20-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 473.76 | 31-OCT-11:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 750.72 | 22-NOV-02:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1149.21 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.29 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 166.82 | 1349.48 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 338.00 | 04-JAN-12:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 368.19 | 12-FEB-23:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 192.74 | 14-MAR-16:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.88 | 23-APR-16:00 | 190.06 | 19-APR-10:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.15 | 25-MAY-15:00 | 78.88 | 20-MAY-06:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.05 | 29-JUN-16:00 | 94.92 | 09-JUN-09:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.63 | 15-JUL-15:00 | 66.02 | 03-JUL-11:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.38 | 08-AUG-16:00 | 113.27 | 17-AUG-14:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 89.41 | 20-SEP-01:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 133.34 | 31-OCT-11:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 207.16 | 22-NOV-02:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 309.85 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.02 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.05 | 368.19 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 32434.30 | 06-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 31379.29 | 14-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 28298.42 | 05-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1533.09 | 23-APR-16:03 | 18586.33 | 05-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1428.65 | 25-MAY-16:03 | 13155.12 | 01-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3667.25 | 29-JUN-16:02 | 9018.66 | 04-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1511.66 | 29-JUL-16:03 | 7579.13 | 02-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1731.92 | 08-AUG-16:02 | 9458.57 | 19-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 12011.58 | 06-SEP-06:01 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 16849.67 | 30-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 21986.54 | 25-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 30113.49 | 24-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7579.13 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 3667.25 | 32434.30 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 269.20 | 04-JAN-12:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 292.64 | 12-FEB-23:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 151.46 | 14-MAR-16:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.26 | 23-APR-16:00 | 157.05 | 19-APR-10:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.51 | 24-MAY-15:00 | 67.08 | 20-MAY-06:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.05 | 29-JUN-16:00 | 79.81 | 09-JUN-09:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.01 | 15-JUL-15:00 | 51.90 | 03-JUL-11:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.52 | 08-AUG-16:00 | 96.04 | 17-AUG-14:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 75.79 | 20-SEP-01:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 106.66 | 31-OCT-11:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 166.93 | 22-NOV-02:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 246.82 | 18-DEC-15:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.90 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.05 | 292.64 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 183.03 | 27-JAN-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 480.34 | 22-FEB-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 224.63 |
| March | 549.93 | 17-MAR-16:02 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.25 |
| April | 696.16 | 23-APR-16:10 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 56.27 | 0.00 |
| May | 1528.89 | 18-MAY-16:10 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 28.12 | 0.00 |
| June | 2056.49 | 30-JUN-17:17 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 81.72 | 0.00 |
| July | 2117.29 | 29-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 44.77 | 0.00 |
| August | 2086.80 | 25-AUG-16:04 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 26.72 | 0.00 |
| September | 2101.12 | 01-SEP-16:04 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 11.84 | 0.00 |
| October | 1309.78 | 22-OCT-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.79 |
| November | 481.50 | 17-NOV-18:01 | 2137.50 | 1054.64 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.67 |
| December | 138.17 | 02-DEC-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 138.17 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2117.29 | 2137.50 | 1054.64 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 81.72 | 224.63 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 334.67 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 528.10 |
| March | 212.71 | 28-MAR-17:09 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.69 |
| April | 379.36 | 21-APR-19:20 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.45 |
| May | 1224.86 | 25-MAY-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 15.26 | 0.00 |
| June | 1844.50 | 30-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 68.86 | 0.00 |
| July | 1727.07 | 24-JUL-17:45 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 28.52 | 0.00 |
| August | 1579.70 | 08-AUG-17:05 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 69.61 | 0.00 |
| September | 1372.20 | 01-SEP-16:25 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 8.59 | 0.00 |
| October | 512.91 | 01-OCT-02:30 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.95 |
| November | 287.14 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.92 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 326.26 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 206.62 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1844.50 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 69.61 | 528.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2023.74 | 06-JAN-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1937.49 | 14-FEB-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.24 |
| March | 1582.31 | 15-MAR-07:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 354.53 |
| April | 1086.18 | 05-APR-06:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 5960.89 | 19-MAY-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.64 |
| June | 5975.28 | 15-JUN-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.58 |
| July | 6032.36 | 06-JUL-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.11 |
| August | 6064.64 | 14-AUG-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.78 |
| September | 6184.05 | 05-SEP-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.27 |
| October | 1318.40 | 20-OCT-14:30 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.04 |
| November | 1293.58 | 29-NOV-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 207.48 |
| December | 1758.27 | 20-DEC-07:03 | 0.00 | 1165.83 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 462.74 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1086.18 | 0.00 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6184.05 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 462.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 334.67 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 528.10 |
| March | 0.00 | 01-MAR-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 207.43 |
| April | 279.16 | 22-APR-20:10 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.52 |
| May | 778.95 | 25-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 16.37 | 0.00 |
| June | 1435.84 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 100.07 | 0.00 |
| July | 1389.59 | 23-JUL-16:05 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 58.92 | 0.00 |
| August | 1318.32 | 08-AUG-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.81 | 0.00 |
| September | 1081.03 | 01-SEP-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 10.26 | 0.00 |
| October | 510.02 | 01-OCT-07:30 | 277.88 | 78.12 | 1165.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 286.88 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.88 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 326.26 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 206.62 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1435.84 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 100.07 | 528.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 201.87 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 318.54 |
| March | 88.71 | 28-MAR-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.20 |
| April | 380.33 | 24-APR-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.18 |
| May | 750.54 | 25-MAY-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 8.38 | 0.00 |
| June | 1214.47 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.36 | 0.00 |
| July | 1109.98 | 23-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.82 | 0.00 |
| August | 1051.96 | 08-AUG-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 39.48 | 0.00 |
| September | 898.94 | 01-SEP-17:10 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 1.32 | 0.00 |
| October | 620.72 | 01-OCT-06:00 | 237.50 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.90 |
| November | 296.28 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.90 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196.79 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 123.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1214.47 | 619.87 | 351.55 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 60.36 | 318.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 201.87 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 318.54 |
| March | 83.99 | 28-MAR-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.20 |
| April | 368.20 | 24-APR-17:18 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.09 |
| May | 736.92 | 25-MAY-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 8.38 | 0.00 |
| June | 1206.35 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.36 | 0.00 |
| July | 1104.58 | 23-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.82 | 0.00 |
| August | 1046.51 | 08-AUG-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 39.48 | 0.00 |
| September | 894.38 | 01-SEP-16:30 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 5.18 | 0.00 |
| October | 615.97 | 01-OCT-05:50 | 237.50 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.46 |
| November | 296.30 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.90 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196.79 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 123.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1206.35 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 60.36 | 318.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 404.79 | 27-JAN-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 639.96 | 22-FEB-13:40 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.24 |
| March | 590.27 | 20-MAR-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.46 |
| April | 620.55 | 21-APR-22:00 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 1082.51 | 18-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 18.41 | 0.00 |
| June | 1483.84 | 30-JUN-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 76.36 | 0.00 |
| July | 1574.48 | 23-JUL-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 56.17 | 0.00 |
| August | 1575.79 | 25-AUG-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 18.63 | 0.00 |
| September | 1629.60 | 01-SEP-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 9.11 | 0.00 |
| October | 1225.61 | 22-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.95 |
| November | 690.30 | 10-NOV-13:20 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188.82 |
| December | 414.58 | 02-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.25 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 404.79 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1629.60 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 76.36 | 188.82 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 347.31 | 27-JAN-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 563.49 | 22-FEB-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.96 |
| March | 577.25 | 20-MAR-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.28 |
| April | 620.20 | 21-APR-22:00 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 1126.44 | 18-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 18.41 | 0.00 |
| June | 1553.16 | 30-JUN-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 76.36 | 0.00 |
| July | 1714.75 | 23-JUL-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 56.17 | 0.00 |
| August | 1679.65 | 26-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 14.43 | 0.00 |
| September | 1691.23 | 01-SEP-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 9.11 | 0.00 |
| October | 1264.72 | 22-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.95 |
| November | 678.91 | 10-NOV-13:40 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.00 |
| December | 296.77 | 02-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.25 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 296.77 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1714.75 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 76.36 | 175.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1062.09 | 27-JAN-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.66 |
| February | 884.83 | 19-FEB-16:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 314.04 |
| March | 942.61 | 12-MAR-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.69 |
| April | 2391.37 | 23-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 80.25 | 0.00 |
| May | 2612.71 | 18-MAY-16:03 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 40.23 | 0.00 |
| June | 2837.74 | 30-JUN-17:17 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 117.09 | 0.00 |
| July | 2858.66 | 29-JUL-16:10 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 64.14 | 0.00 |
| August | 2671.70 | 25-AUG-16:04 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 38.21 | 0.00 |
| September | 2787.81 | 01-SEP-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 20.48 | 0.00 |
| October | 2066.10 | 22-OCT-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.63 |
| November | 738.05 | 10-NOV-16:45 | 0.00 | 121.52 | 941.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.81 |
| December | 1046.35 | 02-DEC-14:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.55 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 738.05 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2858.66 | 712.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 117.09 | 314.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 481.18 |
| February | 266.43 | 08-FEB-16:30 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 208.31 |
| March | 585.33 | 28-MAR-21:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.50 |
| April | 1235.67 | 23-APR-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 50.23 | 0.00 |
| May | 2330.27 | 25-MAY-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 21.83 | 0.00 |
| June | 2614.56 | 30-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 98.62 | 0.00 |
| July | 2343.07 | 24-JUL-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 44.87 | 0.00 |
| August | 2090.26 | 08-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 121.73 | 0.00 |
| September | 1831.93 | 01-SEP-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 14.56 | 0.00 |
| October | 632.36 | 01-OCT-06:00 | 237.50 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.16 |
| November | 303.37 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.08 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 469.17 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2614.56 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 121.73 | 481.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1032.73 | 27-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 872.92 | 27-FEB-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 656.31 |
| March | 985.45 | 12-MAR-10:30 | 118.75 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.10 |
| April | 1734.30 | 23-APR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 59.84 | 0.00 |
| May | 2382.30 | 18-MAY-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 45.75 | 0.00 |
| June | 2417.06 | 30-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 145.63 | 0.00 |
| July | 2519.69 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 80.77 | 0.00 |
| August | 2394.63 | 25-AUG-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 45.03 | 0.00 |
| September | 2466.91 | 01-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 10.41 | 0.00 |
| October | 1960.19 | 22-OCT-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.07 |
| November | 720.05 | 10-NOV-12:00 | 0.00 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 537.48 |
| December | 840.10 | 02-DEC-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.86 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 720.05 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2519.69 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 145.63 | 656.31 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 481.18 |
| February | 53.83 | 22-FEB-10:00 | 59.38 | 17.36 | 394.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 438.82 | 29-MAR-11:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.46 |
| April | 677.22 | 13-APR-02:30 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.88 |
| May | 1589.32 | 18-MAY-09:50 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 7.68 | 0.00 |
| June | 1957.75 | 28-JUN-10:20 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 55.60 | 0.00 |
| July | 1872.86 | 29-JUL-10:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 35.99 | 0.00 |
| August | 1663.58 | 08-AUG-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 132.80 | 0.00 |
| September | 1330.77 | 01-SEP-16:17 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 14.56 | 0.00 |
| October | 626.51 | 01-OCT-06:00 | 237.50 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.23 |
| November | 302.94 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.99 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 469.17 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 59.38 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1957.75 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 132.80 | 481.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 164.69 | 29-JAN-17:03 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.47 |
| February | 265.75 | 08-FEB-18:09 | 2066.25 | 1171.82 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.79 |
| March | 543.37 | 28-MAR-20:30 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.74 |
| April | 685.72 | 13-APR-02:40 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.46 |
| May | 1342.30 | 25-MAY-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 11.98 | 0.00 |
| June | 1563.33 | 29-JUN-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 81.90 | 0.00 |
| July | 1359.74 | 20-JUL-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 12.39 | 0.00 |
| August | 1267.21 | 08-AUG-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 56.51 | 0.00 |
| September | 1061.01 | 01-SEP-16:30 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 0.00 |
| October | 680.38 | 04-OCT-03:00 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 417.98 | 14-NOV-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 156.72 | 05-DEC-18:14 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.06 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 156.72 | 206.62 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1563.33 | 2066.25 | 1171.82 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 81.90 | 84.79 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 162.95 | 29-JAN-17:03 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.47 |
| February | 260.99 | 08-FEB-18:09 | 2066.25 | 1171.82 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.79 |
| March | 524.74 | 28-MAR-20:20 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.11 |
| April | 685.81 | 13-APR-02:40 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.47 |
| May | 1325.67 | 25-MAY-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 11.98 | 0.00 |
| June | 1550.39 | 29-JUN-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 81.90 | 0.00 |
| July | 1347.53 | 20-JUL-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 12.39 | 0.00 |
| August | 1260.19 | 08-AUG-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 56.51 | 0.00 |
| September | 1054.73 | 01-SEP-16:30 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 0.00 |
| October | 680.10 | 04-OCT-03:00 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 417.05 | 02-NOV-16:04 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.00 |
| December | 156.47 | 05-DEC-18:14 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.06 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 156.47 | 206.62 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1550.39 | 2066.25 | 1171.82 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 81.90 | 112.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1118.61 | 27-JAN-12:20 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1018.30 | 10-FEB-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 252.11 |
| March | 1021.81 | 12-MAR-19:00 | 237.50 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1597.31 | 23-APR-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 32.20 | 0.00 |
| May | 1889.17 | 18-MAY-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 27.39 | 0.00 |
| June | 1921.19 | 30-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 87.84 | 0.00 |
| July | 1989.97 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 48.72 | 0.00 |
| August | 1949.88 | 25-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 30.47 | 0.00 |
| September | 2097.20 | 01-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.28 | 0.00 |
| October | 1927.91 | 22-OCT-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.17 |
| November | 807.83 | 10-NOV-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.03 |
| December | 1196.29 | 02-DEC-12:50 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.10 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 807.83 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2097.20 | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 87.84 | 252.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1118.72 | 27-JAN-12:20 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1018.41 | 10-FEB-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 252.14 |
| March | 1021.45 | 12-MAR-19:00 | 237.50 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1593.29 | 23-APR-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 32.20 | 0.00 |
| May | 1894.89 | 18-MAY-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 27.39 | 0.00 |
| June | 1921.00 | 30-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 87.84 | 0.00 |
| July | 1995.60 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 48.72 | 0.00 |
| August | 1955.34 | 25-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 30.47 | 0.00 |
| September | 2104.49 | 01-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.28 | 0.00 |
| October | 1932.57 | 22-OCT-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.17 |
| November | 807.72 | 10-NOV-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.02 |
| December | 1200.27 | 02-DEC-12:40 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.66 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 807.72 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2104.49 | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 87.84 | 252.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1063.51 | 27-JAN-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 925.70 | 28-FEB-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 431.45 |
| March | 1601.69 | 19-MAR-16:01 | 2375.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 246.47 |
| April | 3027.18 | 23-APR-16:03 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 104.52 | 0.00 |
| May | 3461.18 | 18-MAY-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 55.72 | 0.00 |
| June | 3722.24 | 30-JUN-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 166.78 | 0.00 |
| July | 3827.73 | 29-JUL-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 84.33 | 0.00 |
| August | 3475.54 | 11-AUG-16:04 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 26.49 | 0.00 |
| September | 3684.38 | 01-SEP-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 26.57 | 0.00 |
| October | 2360.82 | 19-OCT-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.93 |
| November | 701.46 | 10-NOV-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 641.27 |
| December | 916.50 | 02-DEC-14:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.86 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 701.46 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3827.73 | 2375.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 166.78 | 641.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.10 |
| February | 130.16 | 08-FEB-16:30 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 276.19 |
| March | 628.48 | 23-MAR-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.13 |
| April | 2013.50 | 23-APR-17:15 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 64.90 | 0.00 |
| May | 3019.09 | 25-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.77 | 0.00 |
| June | 3458.35 | 29-JUN-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 176.97 | 0.00 |
| July | 3066.27 | 29-JUL-17:05 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 54.36 | 0.00 |
| August | 2844.41 | 08-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 159.95 | 0.00 |
| September | 2431.35 | 01-SEP-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 18.75 | 0.00 |
| October | 488.79 | 26-OCT-19:50 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.89 |
| November | 305.79 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.07 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 621.44 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3458.35 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 176.97 | 637.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 999.38 | 27-JAN-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 867.66 | 27-FEB-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 819.55 |
| March | 1017.34 | 23-MAR-14:00 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 2138.04 | 23-APR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 77.55 | 0.00 |
| May | 3167.81 | 18-MAY-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 59.96 | 0.00 |
| June | 3317.75 | 30-JUN-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 166.59 | 0.00 |
| July | 3424.43 | 23-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 106.13 | 0.00 |
| August | 3105.47 | 24-AUG-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 | 0.00 |
| September | 3285.45 | 01-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 13.22 | 0.00 |
| October | 2212.27 | 22-OCT-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.54 |
| November | 709.15 | 10-NOV-12:30 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 674.84 |
| December | 640.40 | 02-DEC-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.18 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 640.40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3424.43 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 166.59 | 819.55 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.10 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1005.28 |
| March | 358.32 | 28-MAR-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.59 |
| April | 1026.99 | 23-APR-17:15 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 64.90 | 0.00 |
| May | 2006.67 | 18-MAY-16:10 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 52.73 | 0.00 |
| June | 2566.39 | 29-JUN-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 256.38 | 0.00 |
| July | 2407.12 | 29-JUL-10:20 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 45.62 | 0.00 |
| August | 2198.78 | 08-AUG-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 174.58 | 0.00 |
| September | 1670.60 | 01-SEP-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 21.77 | 0.00 |
| October | 484.03 | 01-OCT-02:00 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.84 |
| November | 303.80 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.51 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 621.44 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 59.38 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2566.39 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 256.38 | 1005.28 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 384.28 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 606.36 |
| March | 418.06 | 28-MAR-18:20 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.93 |
| April | 865.61 | 23-APR-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 38.38 | 0.00 |
| May | 1720.70 | 25-MAY-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 17.26 | 0.00 |
| June | 2089.31 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 113.97 | 0.00 |
| July | 1848.88 | 23-JUL-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 62.32 | 0.00 |
| August | 1744.48 | 08-AUG-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 100.86 | 0.00 |
| September | 1378.68 | 01-SEP-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 11.31 | 0.00 |
| October | 502.13 | 26-OCT-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.45 |
| November | 314.35 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.36 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 374.84 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 123.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2089.31 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 113.97 | 606.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 384.28 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 606.36 |
| March | 405.35 | 28-MAR-17:10 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.20 |
| April | 838.07 | 23-APR-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 38.38 | 0.00 |
| May | 1686.83 | 25-MAY-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 17.26 | 0.00 |
| June | 2060.74 | 29-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 113.97 | 0.00 |
| July | 1836.04 | 23-JUL-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 62.32 | 0.00 |
| August | 1731.47 | 08-AUG-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 100.86 | 0.00 |
| September | 1363.48 | 01-SEP-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 11.31 | 0.00 |
| October | 488.04 | 01-OCT-02:00 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.95 |
| November | 314.18 | 01-NOV-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.33 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 374.84 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 123.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2060.74 | 1446.38 | 820.27 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 113.97 | 606.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1093.42 | 27-JAN-12:50 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 952.83 | 10-FEB-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 236.73 |
| March | 1144.16 | 19-MAR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.35 |
| April | 1983.91 | 23-APR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 46.77 | 0.00 |
| May | 2620.99 | 18-MAY-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.90 | 0.00 |
| June | 2721.13 | 30-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 115.56 | 0.00 |
| July | 2795.01 | 29-JUL-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 40.68 | 0.00 |
| August | 2620.88 | 24-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 6.26 | 0.00 |
| September | 2848.62 | 01-SEP-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 10.11 | 0.00 |
| October | 2138.40 | 22-OCT-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.56 |
| November | 737.65 | 10-NOV-16:45 | 0.00 | 121.52 | 941.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.55 |
| December | 1165.78 | 02-DEC-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.46 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 737.65 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2848.62 | 237.50 | 121.52 | 941.80 | 0.00 | 0.00 | 0.00 | 0.00 | 115.56 | 236.73 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1093.66 | 27-JAN-12:50 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 963.72 | 10-FEB-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 236.73 |
| March | 1136.68 | 19-MAR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.35 |
| April | 1971.82 | 23-APR-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 46.77 | 0.00 |
| May | 2631.92 | 18-MAY-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.90 | 0.00 |
| June | 2722.73 | 30-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 115.56 | 0.00 |
| July | 2807.64 | 29-JUL-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 40.68 | 0.00 |
| August | 2628.29 | 24-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 6.26 | 0.00 |
| September | 2862.03 | 01-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 7.97 | 0.00 |
| October | 2150.55 | 22-OCT-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.56 |
| November | 736.75 | 10-NOV-16:45 | 0.00 | 121.52 | 941.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.32 |
| December | 1165.91 | 02-DEC-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.46 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 736.75 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2862.03 | 237.50 | 121.52 | 941.80 | 0.00 | 0.00 | 0.00 | 0.00 | 115.56 | 236.73 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.42 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.33 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.43 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.12 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.42 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.21 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.82 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.30 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.34 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.24 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.52 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.05 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.82 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.33 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.18 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.22 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.95 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.87 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.05 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.49 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.96 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.65 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.35 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.37 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.14 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.48 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.96 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.34 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.36 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.48 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.07 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.24 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.28 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.11 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.28 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.60 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.04 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.93 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.28 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.36 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.112694E+12 | 78300.96 | 26-JAN-07:10 | 0.224575E+12 | 146802.58 | 04-JAN-08:09 |
| February | 0.100679E+12 | 77935.82 | 06-FEB-07:19 | 0.157568E+12 | 128665.78 | 14-FEB-04:00 |
| March | 0.108993E+12 | 72264.59 | 07-MAR-18:40 | 0.120829E+12 | 111314.54 | 05-MAR-03:00 |
| April | 0.102311E+12 | 75268.69 | 23-APR-16:30 | 0.447208E+11 | 66267.61 | 05-APR-03:00 |
| May | 0.110484E+12 | 82336.39 | 25-MAY-17:19 | 0.332587E+10 | 28502.68 | 01-MAY-03:00 |
| June | 0.115663E+12 | 90409.55 | 29-JUN-16:30 | 48964731.37 | 3879.85 | 04-JUN-04:19 |
| July | 0.125691E+12 | 88865.96 | 29-JUL-16:19 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 0.116901E+12 | 86040.99 | 08-AUG-17:10 | 60582232.29 | 4113.79 | 19-AUG-05:30 |
| September | 0.999611E+11 | 81650.46 | 01-SEP-17:40 | 0.216511E+10 | 7609.57 | 28-SEP-05:00 |
| October | 0.100907E+12 | 66827.67 | 21-OCT-17:00 | 0.332960E+11 | 61843.98 | 30-OCT-07:10 |
| November | 0.101354E+12 | 65341.24 | 25-NOV-18:40 | 0.101361E+12 | 97644.51 | 25-NOV-05:00 |
| December | 0.110722E+12 | 68425.13 | 12-DEC-18:19 | 0.213084E+12 | 142465.42 | 24-DEC-08:09 |
| Annual Sum or Average | 0.130636E+13 | 0.901035E+12 | ||||
| Minimum of Months | 0.999611E+11 | 65341.24 | 0.00 | 0.00 | ||
| Maximum of Months | 0.125691E+12 | 90409.55 | 0.224575E+12 | 146802.58 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.547596E+10 | 0.389380E+11 | 0.00 | 0.120012E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478692E+11 | 0.00 |
| February | 0.760941E+10 | 0.449805E+10 | 0.351823E+11 | 0.00 | 0.935233E+10 | 0.00 | 0.00 | 2169064.85 | 0.00 | 0.00 | 0.00 | 0.440348E+11 | 0.00 |
| March | 0.845392E+10 | 0.437199E+10 | 0.389781E+11 | 0.00 | 0.857552E+10 | 0.00 | 0.00 | 27651156.53 | 0.00 | 0.00 | 0.00 | 0.485860E+11 | 0.00 |
| April | 0.814762E+10 | 0.361945E+10 | 0.376905E+11 | 0.00 | 0.616597E+10 | 0.00 | 0.00 | 0.850545E+09 | 0.00 | 0.00 | 0.00 | 0.458372E+11 | 0.00 |
| May | 0.843904E+10 | 0.318970E+10 | 0.389647E+11 | 0.00 | 0.694445E+10 | 0.00 | 0.00 | 0.765840E+10 | 0.00 | 0.00 | 0.00 | 0.452878E+11 | 0.00 |
| June | 0.817737E+10 | 0.278860E+10 | 0.377173E+11 | 0.00 | 0.910641E+10 | 0.00 | 0.00 | 0.161600E+11 | 0.00 | 0.00 | 0.00 | 0.417129E+11 | 0.00 |
| July | 0.840929E+10 | 0.302162E+10 | 0.389380E+11 | 0.00 | 0.111926E+11 | 0.00 | 0.00 | 0.228082E+11 | 0.00 | 0.00 | 0.00 | 0.413212E+11 | 0.00 |
| August | 0.845392E+10 | 0.349339E+10 | 0.389781E+11 | 0.00 | 0.930141E+10 | 0.00 | 0.00 | 0.162834E+11 | 0.00 | 0.00 | 0.00 | 0.403911E+11 | 0.00 |
| September | 0.814762E+10 | 0.396325E+10 | 0.376905E+11 | 0.00 | 0.592023E+10 | 0.00 | 0.00 | 0.491444E+10 | 0.00 | 0.00 | 0.00 | 0.393250E+11 | 0.00 |
| October | 0.842417E+10 | 0.472916E+10 | 0.389514E+11 | 0.00 | 0.593496E+10 | 0.00 | 0.00 | 0.848779E+09 | 0.00 | 0.00 | 0.00 | 0.420189E+11 | 0.00 |
| November | 0.814762E+10 | 0.513216E+10 | 0.376905E+11 | 0.00 | 0.781384E+10 | 0.00 | 0.00 | 1156474.17 | 0.00 | 0.00 | 0.00 | 0.425690E+11 | 0.00 |
| December | 0.840929E+10 | 0.562303E+10 | 0.389380E+11 | 0.00 | 0.116400E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.461112E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.499063E+11 | 0.458657E+12 | 0.00 | 0.103949E+12 | 0.00 | 0.00 | 0.695547E+11 | 0.00 | 0.00 | 0.00 | 0.525064E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.278860E+10 | 0.351823E+11 | 0.00 | 0.592023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.393250E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.562303E+10 | 0.389781E+11 | 0.00 | 0.120012E+11 | 0.00 | 0.00 | 0.228082E+11 | 0.00 | 0.00 | 0.00 | 0.485860E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.224575E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.157568E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.120829E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.447208E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.332587E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 48964731.37 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 60582232.29 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.216511E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.332960E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.101361E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.213084E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.901035E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.224575E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 6597.13 | 04-JAN-05:00 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 5989.94 | 14-FEB-04:00 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 5401.09 | 05-MAR-03:00 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 4925.77 | 23-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 6891.94 | 25-MAY-17:00 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 9280.92 | 29-JUN-16:10 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 8488.94 | 23-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 8260.31 | 08-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 6876.24 | 01-SEP-15:20 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 3890.24 | 22-OCT-13:50 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 4980.46 | 25-NOV-05:00 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 6428.06 | 24-DEC-08:09 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 3890.24 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 9280.92 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 49695.97 | 26-JAN-07:10 | 0.00 |
| February | 301.29 | 28-FEB-15:30 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 50557.77 | 03-FEB-07:40 | 0.00 |
| March | 855.77 | 26-MAR-15:20 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 45053.85 | 21-MAR-06:00 | 0.00 |
| April | 10878.90 | 23-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 44431.90 | 01-APR-06:40 | 0.00 |
| May | 18188.14 | 25-MAY-15:20 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 36109.69 | 08-MAY-06:49 | 0.00 |
| June | 28981.74 | 29-JUN-15:00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 34312.94 | 04-JUN-06:19 | 0.00 |
| July | 24806.63 | 15-JUL-14:30 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 37255.07 | 14-JUL-06:30 | 0.00 |
| August | 24467.00 | 08-AUG-15:20 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 36857.40 | 25-AUG-06:49 | 0.00 |
| September | 18352.84 | 01-SEP-15:20 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 36020.88 | 22-SEP-05:40 | 0.00 |
| October | 7145.44 | 22-OCT-13:50 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 33265.04 | 04-OCT-06:30 | 0.00 |
| November | 174.37 | 17-NOV-13:39 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 33512.95 | 25-NOV-07:10 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 37241.76 | 27-DEC-07:49 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 33265.04 | 0.00 | |||
| Maximum of Months | 28981.74 | 0.00 | 0.00 | 0.00 | 50557.77 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 78300.96 | 26-JAN-07:10 | 3348.00 | 16323.13 | 3183.33 | 0.00 | 5750.52 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77935.82 | 06-FEB-07:19 | 3348.00 | 16323.13 | 3183.33 | 0.00 | 4773.20 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 72264.59 | 07-MAR-18:40 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 3438.24 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 75268.69 | 23-APR-16:30 | 4289.87 | 22609.62 | 0.00 | 0.00 | 4874.46 | 0.00 | 0.00 | 10684.52 | 0.00 |
| May | 82336.39 | 25-MAY-17:19 | 5231.74 | 22609.62 | 0.00 | 0.00 | 6867.96 | 0.00 | 0.00 | 18014.54 | 0.00 |
| June | 90409.55 | 29-JUN-16:30 | 4289.87 | 22709.69 | 0.00 | 0.00 | 9172.48 | 0.00 | 0.00 | 28267.02 | 0.00 |
| July | 88865.96 | 29-JUL-16:19 | 4289.87 | 22609.62 | 0.00 | 0.00 | 8115.70 | 0.00 | 0.00 | 22859.75 | 0.00 |
| August | 86040.99 | 08-AUG-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7926.57 | 0.00 | 0.00 | 22037.24 | 0.00 |
| September | 81650.46 | 01-SEP-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 6218.35 | 0.00 | 0.00 | 14876.14 | 0.00 |
| October | 66827.67 | 21-OCT-17:00 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2708.32 | 0.00 | 0.00 | 3256.90 | 0.00 |
| November | 65341.24 | 25-NOV-18:40 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 3802.99 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 68425.13 | 12-DEC-18:19 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 4722.33 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 65341.24 | 3348.00 | 16323.13 | 0.00 | 0.00 | 2708.32 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 90409.55 | 5231.74 | 22709.69 | 3183.33 | 0.00 | 9172.48 | 0.00 | 0.00 | 28267.02 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 146802.58 | 04-JAN-08:09 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 128665.78 | 14-FEB-04:00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 111314.54 | 05-MAR-03:00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 66267.61 | 05-APR-03:00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 28502.68 | 01-MAY-03:00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 3879.85 | 04-JUN-04:19 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 4113.79 | 19-AUG-05:30 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 7609.57 | 28-SEP-05:00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 61843.98 | 30-OCT-07:10 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 97644.51 | 25-NOV-05:00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 142465.42 | 24-DEC-08:09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 146802.58 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| February | 473.00 | 21.10 | 471.50 | 21.10 | 471.50 | 21.10 |
| March | 506.00 | 21.11 | 487.67 | 21.10 | 487.67 | 21.10 |
| April | 506.50 | 21.30 | 339.50 | 21.22 | 339.50 | 21.18 |
| May | 405.67 | 22.40 | 44.33 | 22.41 | 22.67 | 22.35 |
| June | 288.83 | 23.22 | 183.67 | 23.51 | 70.83 | 23.56 |
| July | 75.50 | 23.92 | 396.50 | 23.99 | 61.17 | 23.99 |
| August | 37.33 | 23.36 | 354.33 | 23.94 | 7.50 | 23.94 |
| September | 251.83 | 22.86 | 85.50 | 23.15 | 5.00 | 23.16 |
| October | 507.33 | 21.69 | 118.83 | 21.59 | 115.83 | 21.51 |
| November | 510.00 | 21.10 | 464.50 | 21.10 | 464.50 | 21.10 |
| December | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| Annual Sum or Average | 4628.00 | 21.59 | 4012.33 | 21.71 | 3112.17 | 21.59 |
| Minimum of Months | 37.33 | 21.10 | 44.33 | 21.10 | 5.00 | 21.10 |
| Maximum of Months | 533.00 | 23.92 | 533.00 | 23.99 | 533.00 | 23.99 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.15 | 625.67 | 21.13 | 625.67 | 21.12 |
| May | 627.00 | 22.17 | 95.33 | 22.12 | 74.00 | 22.02 |
| June | 453.50 | 23.29 | 263.67 | 23.54 | 101.33 | 23.59 |
| July | 114.50 | 23.91 | 517.33 | 23.98 | 92.00 | 23.99 |
| August | 90.17 | 23.52 | 438.50 | 23.91 | 26.83 | 23.92 |
| September | 570.50 | 22.71 | 67.17 | 22.84 | 15.17 | 22.86 |
| October | 744.00 | 21.24 | 297.33 | 21.20 | 297.33 | 21.18 |
| November | 720.00 | 21.10 | 662.17 | 21.10 | 662.17 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6943.67 | 21.57 | 5871.17 | 21.65 | 4798.50 | 21.54 |
| Minimum of Months | 90.17 | 21.10 | 67.17 | 21.10 | 15.17 | 21.10 |
| Maximum of Months | 744.00 | 23.91 | 744.00 | 23.98 | 744.00 | 23.99 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 140.00 | 20.94 | 140.00 | 20.94 | 140.00 | 20.94 |
| February | 133.00 | 20.94 | 133.00 | 20.94 | 133.00 | 20.94 |
| March | 161.00 | 20.94 | 159.33 | 20.94 | 159.33 | 20.94 |
| April | 140.00 | 21.68 | 79.17 | 21.39 | 79.17 | 21.26 |
| May | 93.50 | 23.09 | 48.50 | 23.26 | 9.50 | 23.11 |
| June | 12.00 | 24.57 | 110.83 | 24.27 | 4.67 | 24.31 |
| July | 4.00 | 25.46 | 140.00 | 24.27 | 4.00 | 24.30 |
| August | 2.17 | 25.62 | 152.17 | 24.26 | 2.17 | 24.28 |
| September | 41.17 | 23.70 | 68.50 | 24.00 | 0.33 | 24.00 |
| October | 134.33 | 22.09 | 51.00 | 21.76 | 51.00 | 21.57 |
| November | 140.00 | 21.00 | 120.50 | 20.96 | 120.50 | 20.95 |
| December | 140.00 | 20.94 | 140.00 | 20.94 | 140.00 | 20.94 |
| Annual Sum or Average | 1141.17 | 21.51 | 1343.00 | 21.87 | 843.67 | 21.65 |
| Minimum of Months | 2.17 | 20.94 | 48.50 | 20.94 | 0.33 | 20.94 |
| Maximum of Months | 161.00 | 25.62 | 159.33 | 24.27 | 159.33 | 24.31 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.14 | 630.83 | 21.12 | 630.83 | 21.12 |
| May | 630.00 | 22.14 | 80.50 | 22.06 | 70.83 | 21.98 |
| June | 414.83 | 23.36 | 265.83 | 23.60 | 104.17 | 23.64 |
| July | 134.83 | 23.87 | 522.67 | 23.97 | 98.67 | 23.98 |
| August | 103.00 | 23.59 | 440.50 | 23.92 | 28.67 | 23.93 |
| September | 576.00 | 22.75 | 65.33 | 22.87 | 16.17 | 22.89 |
| October | 744.00 | 21.23 | 307.00 | 21.19 | 307.00 | 21.17 |
| November | 720.00 | 21.10 | 659.83 | 21.10 | 659.83 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6946.67 | 21.57 | 5876.50 | 21.65 | 4820.17 | 21.54 |
| Minimum of Months | 103.00 | 21.10 | 65.33 | 21.10 | 16.17 | 21.10 |
| Maximum of Months | 744.00 | 23.87 | 744.00 | 23.97 | 744.00 | 23.98 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.13 | 608.33 | 21.12 | 608.33 | 21.12 |
| May | 609.00 | 22.20 | 58.50 | 22.15 | 48.17 | 22.08 |
| June | 436.00 | 23.55 | 255.17 | 23.71 | 97.33 | 23.74 |
| July | 114.00 | 23.98 | 476.83 | 24.00 | 107.50 | 24.00 |
| August | 62.17 | 23.72 | 428.50 | 23.96 | 25.67 | 23.96 |
| September | 551.67 | 22.99 | 63.17 | 23.09 | 11.83 | 23.10 |
| October | 744.00 | 21.27 | 188.50 | 21.24 | 188.50 | 21.22 |
| November | 720.00 | 21.11 | 638.83 | 21.10 | 638.83 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6860.83 | 21.60 | 5621.83 | 21.66 | 4630.17 | 21.55 |
| Minimum of Months | 62.17 | 21.10 | 58.50 | 21.10 | 11.83 | 21.10 |
| Maximum of Months | 744.00 | 23.98 | 744.00 | 24.00 | 744.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 672.00 | 21.10 | 672.00 | 21.10 |
| March | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| April | 720.00 | 21.13 | 612.00 | 21.12 | 612.00 | 21.12 |
| May | 610.33 | 22.20 | 58.67 | 22.15 | 48.33 | 22.08 |
| June | 432.00 | 23.56 | 255.17 | 23.72 | 97.50 | 23.75 |
| July | 114.67 | 23.97 | 477.67 | 24.00 | 107.50 | 24.00 |
| August | 61.33 | 23.72 | 427.83 | 23.96 | 26.00 | 23.97 |
| September | 550.17 | 22.99 | 63.17 | 23.09 | 12.00 | 23.10 |
| October | 744.00 | 21.27 | 188.83 | 21.24 | 188.83 | 21.21 |
| November | 720.00 | 21.11 | 639.00 | 21.10 | 639.00 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6856.50 | 21.60 | 5626.33 | 21.66 | 4635.17 | 21.55 |
| Minimum of Months | 61.33 | 21.10 | 58.67 | 21.10 | 12.00 | 21.10 |
| Maximum of Months | 744.00 | 23.97 | 744.00 | 24.00 | 744.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| February | 473.00 | 21.10 | 466.17 | 21.10 | 466.17 | 21.10 |
| March | 506.00 | 21.11 | 462.17 | 21.10 | 462.17 | 21.10 |
| April | 510.00 | 21.35 | 272.83 | 21.26 | 272.83 | 21.22 |
| May | 379.33 | 22.48 | 34.83 | 22.48 | 18.67 | 22.42 |
| June | 252.50 | 23.50 | 182.50 | 23.71 | 61.67 | 23.74 |
| July | 68.50 | 23.98 | 381.67 | 24.00 | 64.83 | 24.00 |
| August | 22.50 | 23.58 | 341.33 | 23.97 | 6.00 | 23.97 |
| September | 206.17 | 23.15 | 99.17 | 23.43 | 0.67 | 23.43 |
| October | 502.67 | 21.89 | 50.83 | 21.83 | 47.83 | 21.77 |
| November | 510.00 | 21.11 | 402.00 | 21.10 | 402.00 | 21.10 |
| December | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| Annual Sum or Average | 4496.67 | 21.62 | 3759.50 | 21.74 | 2868.83 | 21.61 |
| Minimum of Months | 22.50 | 21.10 | 34.83 | 21.10 | 0.67 | 21.10 |
| Maximum of Months | 533.00 | 23.98 | 533.00 | 24.00 | 533.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| February | 473.00 | 21.10 | 473.00 | 21.10 | 473.00 | 21.10 |
| March | 506.00 | 21.10 | 488.17 | 21.10 | 488.17 | 21.10 |
| April | 510.00 | 21.34 | 287.83 | 21.25 | 287.83 | 21.21 |
| May | 375.50 | 22.49 | 38.00 | 22.50 | 19.50 | 22.43 |
| June | 224.50 | 23.53 | 184.83 | 23.74 | 51.67 | 23.76 |
| July | 50.50 | 23.98 | 405.33 | 24.00 | 47.17 | 24.00 |
| August | 13.83 | 23.49 | 364.00 | 23.98 | 2.33 | 23.98 |
| September | 194.83 | 23.19 | 116.17 | 23.49 | 0.00 | 23.49 |
| October | 501.67 | 21.90 | 68.50 | 21.82 | 65.00 | 21.75 |
| November | 510.00 | 21.11 | 423.00 | 21.10 | 423.00 | 21.10 |
| December | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| Annual Sum or Average | 4425.83 | 21.59 | 3914.83 | 21.74 | 2923.67 | 21.60 |
| Minimum of Months | 13.83 | 21.10 | 38.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.98 | 533.00 | 24.00 | 533.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 531.00 | 21.10 | 531.00 | 21.10 |
| February | 473.00 | 21.13 | 412.67 | 21.12 | 412.67 | 21.11 |
| March | 506.00 | 21.27 | 340.50 | 21.20 | 340.50 | 21.17 |
| April | 491.17 | 21.95 | 95.33 | 21.84 | 88.00 | 21.75 |
| May | 265.67 | 23.28 | 49.33 | 23.40 | 0.00 | 23.40 |
| June | 92.50 | 23.79 | 227.17 | 23.93 | 31.00 | 23.94 |
| July | 40.50 | 23.99 | 412.17 | 24.00 | 39.00 | 24.00 |
| August | 31.17 | 23.50 | 354.00 | 23.96 | 5.83 | 23.96 |
| September | 215.33 | 22.96 | 84.50 | 23.25 | 0.00 | 23.25 |
| October | 483.83 | 21.79 | 81.83 | 21.72 | 76.33 | 21.65 |
| November | 510.00 | 21.12 | 390.33 | 21.11 | 390.33 | 21.11 |
| December | 533.00 | 21.10 | 531.83 | 21.10 | 531.83 | 21.10 |
| Annual Sum or Average | 4175.17 | 21.65 | 3510.67 | 21.83 | 2446.50 | 21.67 |
| Minimum of Months | 31.17 | 21.10 | 49.33 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.99 | 531.83 | 24.00 | 531.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 663.17 | 21.10 | 663.17 | 21.10 |
| March | 744.00 | 21.12 | 648.33 | 21.11 | 648.33 | 21.11 |
| April | 710.67 | 21.54 | 224.83 | 21.44 | 224.83 | 21.37 |
| May | 432.67 | 23.18 | 95.83 | 23.27 | 10.00 | 23.23 |
| June | 132.33 | 23.83 | 327.17 | 23.95 | 46.00 | 23.95 |
| July | 58.33 | 23.99 | 574.33 | 24.00 | 56.83 | 24.00 |
| August | 54.67 | 23.59 | 486.67 | 23.96 | 17.33 | 23.96 |
| September | 467.83 | 22.91 | 89.67 | 23.08 | 1.17 | 23.08 |
| October | 744.00 | 21.46 | 174.50 | 21.39 | 174.50 | 21.34 |
| November | 720.00 | 21.11 | 622.17 | 21.10 | 622.17 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6224.50 | 21.58 | 5394.67 | 21.75 | 3952.33 | 21.61 |
| Minimum of Months | 54.67 | 21.10 | 89.67 | 21.10 | 1.17 | 21.10 |
| Maximum of Months | 744.00 | 23.99 | 744.00 | 24.00 | 744.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 531.83 | 21.10 | 531.83 | 21.10 |
| February | 473.00 | 21.12 | 415.50 | 21.11 | 415.50 | 21.11 |
| March | 506.00 | 21.23 | 340.67 | 21.18 | 340.67 | 21.16 |
| April | 493.33 | 21.95 | 98.33 | 21.84 | 92.33 | 21.74 |
| May | 286.67 | 23.31 | 47.50 | 23.41 | 0.00 | 23.41 |
| June | 83.83 | 23.80 | 215.33 | 23.94 | 29.33 | 23.94 |
| July | 43.33 | 23.98 | 410.17 | 24.00 | 40.83 | 24.00 |
| August | 26.50 | 23.53 | 352.33 | 23.97 | 6.50 | 23.97 |
| September | 217.17 | 22.94 | 89.67 | 23.25 | 0.00 | 23.25 |
| October | 483.50 | 21.76 | 78.50 | 21.70 | 72.17 | 21.63 |
| November | 510.00 | 21.11 | 392.00 | 21.11 | 392.00 | 21.11 |
| December | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| Annual Sum or Average | 4189.33 | 21.64 | 3504.83 | 21.82 | 2454.17 | 21.67 |
| Minimum of Months | 26.50 | 21.10 | 47.50 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.98 | 533.00 | 24.00 | 533.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 662.17 | 21.10 | 662.17 | 21.10 |
| March | 744.00 | 21.10 | 644.83 | 21.10 | 644.83 | 21.10 |
| April | 714.00 | 21.57 | 225.17 | 21.45 | 225.17 | 21.39 |
| May | 453.67 | 23.26 | 94.00 | 23.37 | 2.83 | 23.36 |
| June | 113.67 | 23.83 | 347.17 | 23.95 | 43.33 | 23.96 |
| July | 66.83 | 23.98 | 588.33 | 24.00 | 63.17 | 24.00 |
| August | 52.33 | 23.65 | 493.50 | 23.97 | 18.00 | 23.97 |
| September | 460.50 | 22.92 | 90.17 | 23.09 | 1.83 | 23.09 |
| October | 744.00 | 21.43 | 163.67 | 21.37 | 163.67 | 21.33 |
| November | 720.00 | 21.11 | 620.50 | 21.10 | 620.50 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6229.00 | 21.59 | 5417.50 | 21.76 | 3933.50 | 21.62 |
| Minimum of Months | 52.33 | 21.10 | 90.17 | 21.10 | 1.83 | 21.10 |
| Maximum of Months | 744.00 | 23.98 | 744.00 | 24.00 | 744.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 655.00 | 21.10 | 655.00 | 21.10 |
| March | 744.00 | 21.10 | 573.50 | 21.10 | 573.50 | 21.10 |
| April | 719.17 | 21.54 | 164.67 | 21.46 | 164.67 | 21.40 |
| May | 449.33 | 23.33 | 50.83 | 23.39 | 0.33 | 23.39 |
| June | 123.17 | 23.93 | 295.00 | 23.98 | 44.17 | 23.98 |
| July | 71.83 | 24.00 | 509.17 | 24.00 | 71.83 | 24.00 |
| August | 29.67 | 23.81 | 439.17 | 23.99 | 17.50 | 23.99 |
| September | 468.83 | 23.31 | 86.67 | 23.41 | 0.67 | 23.41 |
| October | 744.00 | 21.57 | 53.67 | 21.54 | 53.67 | 21.51 |
| November | 720.00 | 21.12 | 561.83 | 21.11 | 561.83 | 21.11 |
| December | 744.00 | 21.10 | 731.50 | 21.10 | 731.50 | 21.10 |
| Annual Sum or Average | 6230.00 | 21.64 | 4865.00 | 21.76 | 3618.67 | 21.63 |
| Minimum of Months | 29.67 | 21.10 | 50.83 | 21.10 | 0.33 | 21.10 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 744.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 655.50 | 21.10 | 655.50 | 21.10 |
| March | 744.00 | 21.10 | 573.17 | 21.10 | 573.17 | 21.10 |
| April | 719.67 | 21.54 | 164.33 | 21.46 | 164.33 | 21.40 |
| May | 449.33 | 23.33 | 53.33 | 23.40 | 0.17 | 23.40 |
| June | 122.33 | 23.93 | 294.83 | 23.98 | 44.00 | 23.98 |
| July | 72.17 | 24.00 | 509.67 | 24.00 | 72.17 | 24.00 |
| August | 29.33 | 23.82 | 439.67 | 23.99 | 17.67 | 23.99 |
| September | 466.50 | 23.30 | 86.67 | 23.41 | 0.67 | 23.41 |
| October | 744.00 | 21.57 | 53.17 | 21.54 | 53.17 | 21.51 |
| November | 720.00 | 21.12 | 561.83 | 21.11 | 561.83 | 21.11 |
| December | 744.00 | 21.10 | 731.50 | 21.10 | 731.50 | 21.10 |
| Annual Sum or Average | 6227.33 | 21.64 | 4867.67 | 21.76 | 3618.17 | 21.63 |
| Minimum of Months | 29.33 | 21.10 | 53.17 | 21.10 | 0.17 | 21.10 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 744.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 505.67 | 21.10 | 505.67 | 21.10 |
| February | 473.00 | 21.17 | 338.00 | 21.14 | 338.00 | 21.13 |
| March | 506.00 | 21.31 | 264.33 | 21.24 | 264.33 | 21.20 |
| April | 494.67 | 22.15 | 50.50 | 22.08 | 44.83 | 22.00 |
| May | 279.17 | 23.52 | 32.83 | 23.57 | 0.00 | 23.57 |
| June | 83.17 | 23.90 | 205.33 | 23.97 | 28.67 | 23.97 |
| July | 43.67 | 24.00 | 393.17 | 24.00 | 43.67 | 24.00 |
| August | 13.67 | 23.69 | 337.00 | 23.99 | 4.50 | 23.99 |
| September | 175.00 | 23.33 | 98.83 | 23.57 | 0.00 | 23.57 |
| October | 464.33 | 22.01 | 22.00 | 22.01 | 16.00 | 21.98 |
| November | 510.00 | 21.15 | 262.50 | 21.14 | 262.50 | 21.13 |
| December | 533.00 | 21.10 | 506.33 | 21.10 | 506.33 | 21.10 |
| Annual Sum or Average | 4108.67 | 21.73 | 3016.50 | 21.90 | 2014.50 | 21.75 |
| Minimum of Months | 13.67 | 21.10 | 22.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 24.00 | 506.33 | 24.00 | 506.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 505.83 | 21.10 | 505.83 | 21.10 |
| February | 473.00 | 21.17 | 338.00 | 21.14 | 338.00 | 21.13 |
| March | 506.00 | 21.31 | 264.33 | 21.24 | 264.33 | 21.20 |
| April | 494.83 | 22.15 | 50.67 | 22.08 | 45.17 | 22.01 |
| May | 280.33 | 23.52 | 32.33 | 23.57 | 0.00 | 23.57 |
| June | 83.17 | 23.90 | 205.33 | 23.97 | 28.67 | 23.97 |
| July | 44.33 | 24.00 | 392.50 | 24.00 | 44.33 | 24.00 |
| August | 13.50 | 23.69 | 337.17 | 23.99 | 4.50 | 23.99 |
| September | 175.17 | 23.32 | 99.50 | 23.57 | 0.00 | 23.57 |
| October | 464.50 | 22.01 | 21.83 | 22.01 | 16.00 | 21.98 |
| November | 510.00 | 21.16 | 262.67 | 21.14 | 262.67 | 21.13 |
| December | 533.00 | 21.10 | 506.17 | 21.10 | 506.17 | 21.10 |
| Annual Sum or Average | 4110.83 | 21.73 | 3016.33 | 21.90 | 2015.67 | 21.75 |
| Minimum of Months | 13.50 | 21.10 | 21.83 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 24.00 | 506.17 | 24.00 | 506.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 531.50 | 21.10 | 531.50 | 21.10 |
| February | 473.00 | 21.14 | 442.17 | 21.12 | 442.17 | 21.11 |
| March | 498.83 | 21.24 | 431.00 | 21.17 | 431.00 | 21.15 |
| April | 475.83 | 21.51 | 286.00 | 21.39 | 278.17 | 21.31 |
| May | 322.00 | 22.29 | 104.67 | 22.47 | 34.67 | 22.37 |
| June | 249.33 | 22.89 | 224.50 | 23.39 | 59.00 | 23.43 |
| July | 191.67 | 23.39 | 360.83 | 23.79 | 79.00 | 23.81 |
| August | 173.50 | 22.98 | 278.33 | 23.60 | 27.17 | 23.62 |
| September | 358.67 | 22.09 | 87.33 | 22.43 | 15.50 | 22.45 |
| October | 493.00 | 21.37 | 251.67 | 21.31 | 243.33 | 21.26 |
| November | 510.00 | 21.11 | 468.67 | 21.10 | 468.67 | 21.10 |
| December | 533.00 | 21.10 | 531.67 | 21.10 | 531.67 | 21.10 |
| Annual Sum or Average | 4811.83 | 21.59 | 3998.33 | 21.71 | 3141.83 | 21.59 |
| Minimum of Months | 173.50 | 21.10 | 87.33 | 21.10 | 15.50 | 21.10 |
| Maximum of Months | 533.00 | 23.39 | 531.67 | 23.79 | 531.67 | 23.81 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 667.67 | 21.10 | 667.67 | 21.10 |
| March | 744.00 | 21.12 | 696.67 | 21.11 | 696.67 | 21.11 |
| April | 709.50 | 21.44 | 459.83 | 21.32 | 454.33 | 21.26 |
| May | 474.00 | 22.26 | 158.83 | 22.47 | 48.67 | 22.37 |
| June | 313.00 | 23.00 | 360.33 | 23.52 | 78.33 | 23.55 |
| July | 218.33 | 23.44 | 536.83 | 23.84 | 102.50 | 23.86 |
| August | 278.17 | 23.02 | 413.17 | 23.59 | 55.33 | 23.62 |
| September | 599.00 | 22.03 | 71.00 | 22.19 | 26.67 | 22.21 |
| October | 741.50 | 21.28 | 411.67 | 21.21 | 411.67 | 21.18 |
| November | 720.00 | 21.11 | 665.00 | 21.10 | 665.00 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6957.50 | 21.55 | 5929.00 | 21.68 | 4694.83 | 21.56 |
| Minimum of Months | 218.33 | 21.10 | 71.00 | 21.10 | 26.67 | 21.10 |
| Maximum of Months | 744.00 | 23.44 | 744.00 | 23.84 | 744.00 | 23.86 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| February | 473.00 | 21.12 | 445.67 | 21.11 | 445.67 | 21.11 |
| March | 502.83 | 21.22 | 433.17 | 21.17 | 433.17 | 21.15 |
| April | 488.83 | 21.55 | 294.50 | 21.41 | 287.67 | 21.32 |
| May | 335.83 | 22.35 | 97.50 | 22.48 | 35.17 | 22.38 |
| June | 244.83 | 22.96 | 217.83 | 23.42 | 59.83 | 23.46 |
| July | 191.50 | 23.38 | 360.17 | 23.78 | 81.50 | 23.81 |
| August | 180.50 | 23.03 | 280.67 | 23.61 | 32.33 | 23.63 |
| September | 363.33 | 22.09 | 84.50 | 22.41 | 18.00 | 22.44 |
| October | 492.00 | 21.36 | 256.17 | 21.30 | 247.83 | 21.25 |
| November | 510.00 | 21.11 | 466.50 | 21.10 | 466.50 | 21.10 |
| December | 533.00 | 21.10 | 533.00 | 21.10 | 533.00 | 21.10 |
| Annual Sum or Average | 4848.67 | 21.60 | 4002.67 | 21.71 | 3173.67 | 21.59 |
| Minimum of Months | 180.50 | 21.10 | 84.50 | 21.10 | 18.00 | 21.10 |
| Maximum of Months | 533.00 | 23.38 | 533.00 | 23.78 | 533.00 | 23.81 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 668.67 | 21.10 | 668.67 | 21.10 |
| March | 744.00 | 21.10 | 699.33 | 21.10 | 699.33 | 21.10 |
| April | 710.33 | 21.46 | 429.00 | 21.32 | 428.00 | 21.26 |
| May | 485.17 | 22.40 | 163.67 | 22.60 | 44.83 | 22.50 |
| June | 285.67 | 23.04 | 377.83 | 23.57 | 78.67 | 23.60 |
| July | 215.67 | 23.42 | 564.50 | 23.84 | 104.50 | 23.86 |
| August | 267.17 | 23.04 | 438.00 | 23.62 | 55.17 | 23.64 |
| September | 602.83 | 22.12 | 71.67 | 22.27 | 27.17 | 22.28 |
| October | 744.00 | 21.27 | 422.67 | 21.21 | 422.67 | 21.18 |
| November | 720.00 | 21.11 | 667.17 | 21.10 | 667.17 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6934.83 | 21.56 | 5990.50 | 21.70 | 4684.17 | 21.58 |
| Minimum of Months | 215.67 | 21.10 | 71.67 | 21.10 | 27.17 | 21.10 |
| Maximum of Months | 744.00 | 23.42 | 744.00 | 23.84 | 744.00 | 23.86 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 668.00 | 21.10 | 668.00 | 21.10 |
| March | 744.00 | 21.10 | 707.00 | 21.10 | 707.00 | 21.10 |
| April | 710.67 | 21.37 | 433.67 | 21.27 | 433.67 | 21.22 |
| May | 501.83 | 22.49 | 116.50 | 22.65 | 26.83 | 22.58 |
| June | 297.00 | 23.28 | 325.00 | 23.64 | 75.67 | 23.67 |
| July | 185.83 | 23.60 | 533.50 | 23.90 | 100.33 | 23.91 |
| August | 211.83 | 23.22 | 412.33 | 23.72 | 41.67 | 23.74 |
| September | 627.33 | 22.28 | 69.83 | 22.45 | 20.00 | 22.48 |
| October | 744.00 | 21.27 | 337.50 | 21.21 | 337.50 | 21.19 |
| November | 720.00 | 21.11 | 651.17 | 21.11 | 651.17 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6902.50 | 21.58 | 5742.50 | 21.69 | 4549.83 | 21.57 |
| Minimum of Months | 185.83 | 21.10 | 69.83 | 21.10 | 20.00 | 21.10 |
| Maximum of Months | 744.00 | 23.60 | 744.00 | 23.90 | 744.00 | 23.91 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| February | 672.00 | 21.10 | 668.17 | 21.10 | 668.17 | 21.10 |
| March | 744.00 | 21.10 | 706.33 | 21.10 | 706.33 | 21.10 |
| April | 710.50 | 21.38 | 431.00 | 21.27 | 431.00 | 21.23 |
| May | 501.50 | 22.49 | 116.67 | 22.65 | 27.00 | 22.59 |
| June | 295.50 | 23.28 | 327.50 | 23.65 | 75.67 | 23.67 |
| July | 187.83 | 23.59 | 534.17 | 23.89 | 101.83 | 23.91 |
| August | 213.00 | 23.22 | 411.50 | 23.72 | 42.50 | 23.74 |
| September | 627.00 | 22.29 | 69.17 | 22.45 | 19.83 | 22.49 |
| October | 744.00 | 21.27 | 338.33 | 21.21 | 338.33 | 21.19 |
| November | 720.00 | 21.11 | 652.00 | 21.11 | 652.00 | 21.10 |
| December | 744.00 | 21.10 | 744.00 | 21.10 | 744.00 | 21.10 |
| Annual Sum or Average | 6903.33 | 21.58 | 5742.83 | 21.69 | 4550.67 | 21.57 |
| Minimum of Months | 187.83 | 21.10 | 69.17 | 21.10 | 19.83 | 21.10 |
| Maximum of Months | 744.00 | 23.59 | 744.00 | 23.89 | 744.00 | 23.91 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 526.83 | 21.10 | 526.83 | 21.10 |
| February | 473.00 | 21.15 | 425.67 | 21.13 | 425.67 | 21.12 |
| March | 502.00 | 21.27 | 410.17 | 21.19 | 410.17 | 21.16 |
| April | 492.17 | 21.67 | 234.00 | 21.51 | 227.33 | 21.41 |
| May | 325.17 | 22.53 | 65.50 | 22.67 | 14.33 | 22.62 |
| June | 233.00 | 23.17 | 205.33 | 23.54 | 56.17 | 23.57 |
| July | 153.67 | 23.55 | 360.83 | 23.86 | 75.17 | 23.88 |
| August | 117.17 | 23.12 | 290.00 | 23.74 | 20.00 | 23.75 |
| September | 339.00 | 22.33 | 79.00 | 22.64 | 12.17 | 22.68 |
| October | 489.67 | 21.47 | 191.00 | 21.40 | 183.50 | 21.33 |
| November | 510.00 | 21.12 | 450.50 | 21.11 | 450.50 | 21.11 |
| December | 533.00 | 21.10 | 528.67 | 21.10 | 528.67 | 21.10 |
| Annual Sum or Average | 4700.83 | 21.64 | 3767.50 | 21.74 | 2930.50 | 21.62 |
| Minimum of Months | 117.17 | 21.10 | 65.50 | 21.10 | 12.17 | 21.10 |
| Maximum of Months | 533.00 | 23.55 | 528.67 | 23.86 | 528.67 | 23.88 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 526.83 | 21.10 | 526.83 | 21.10 |
| February | 473.00 | 21.15 | 425.83 | 21.13 | 425.83 | 21.12 |
| March | 501.83 | 21.26 | 410.33 | 21.19 | 410.33 | 21.16 |
| April | 492.33 | 21.67 | 235.67 | 21.51 | 229.00 | 21.41 |
| May | 326.33 | 22.53 | 66.67 | 22.68 | 14.50 | 22.62 |
| June | 234.00 | 23.17 | 205.17 | 23.54 | 56.33 | 23.58 |
| July | 154.00 | 23.54 | 359.83 | 23.86 | 75.50 | 23.88 |
| August | 117.00 | 23.12 | 289.00 | 23.74 | 20.33 | 23.75 |
| September | 339.67 | 22.33 | 79.17 | 22.64 | 12.33 | 22.68 |
| October | 489.50 | 21.46 | 191.67 | 21.39 | 184.17 | 21.33 |
| November | 510.00 | 21.12 | 450.50 | 21.11 | 450.50 | 21.11 |
| December | 533.00 | 21.10 | 528.50 | 21.10 | 528.50 | 21.10 |
| Annual Sum or Average | 4703.67 | 21.64 | 3769.17 | 21.74 | 2934.17 | 21.62 |
| Minimum of Months | 117.00 | 21.10 | 66.67 | 21.10 | 12.33 | 21.10 |
| Maximum of Months | 533.00 | 23.54 | 528.50 | 23.86 | 528.50 | 23.88 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 18.85 | 744.00 | 18.85 | 744.00 | 18.85 |
| February | 672.00 | 19.53 | 551.17 | 19.38 | 551.17 | 19.32 |
| March | 744.00 | 20.32 | 413.00 | 20.08 | 413.00 | 19.96 |
| April | 686.50 | 21.78 | 299.33 | 21.92 | 278.33 | 21.95 |
| May | 722.00 | 24.39 | 732.67 | 24.41 | 711.17 | 24.41 |
| June | 720.00 | 25.41 | 720.00 | 25.41 | 720.00 | 25.41 |
| July | 744.00 | 25.82 | 744.00 | 25.82 | 744.00 | 25.82 |
| August | 744.00 | 25.39 | 744.00 | 25.39 | 744.00 | 25.39 |
| September | 720.00 | 23.73 | 707.83 | 23.74 | 707.83 | 23.75 |
| October | 739.67 | 21.59 | 477.17 | 21.75 | 477.17 | 21.82 |
| November | 720.00 | 20.19 | 430.33 | 20.02 | 430.33 | 19.95 |
| December | 744.00 | 18.93 | 744.00 | 18.93 | 744.00 | 18.93 |
| Annual Sum or Average | 8700.17 | 22.17 | 7307.50 | 22.27 | 7265.00 | 22.30 |
| Minimum of Months | 672.00 | 18.85 | 299.33 | 18.85 | 278.33 | 18.85 |
| Maximum of Months | 744.00 | 25.82 | 744.00 | 25.82 | 744.00 | 25.82 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 13.58 | 744.00 | 13.58 | 744.00 | 13.58 |
| February | 672.00 | 14.93 | 672.00 | 14.93 | 672.00 | 14.93 |
| March | 744.00 | 16.09 | 744.00 | 16.09 | 744.00 | 16.09 |
| April | 720.00 | 18.85 | 583.50 | 18.56 | 583.50 | 18.45 |
| May | 560.17 | 21.78 | 272.33 | 22.13 | 137.17 | 21.91 |
| June | 480.67 | 24.42 | 455.17 | 24.89 | 294.33 | 25.04 |
| July | 478.50 | 25.78 | 695.83 | 25.78 | 454.33 | 25.84 |
| August | 427.67 | 25.04 | 655.83 | 25.22 | 366.33 | 25.31 |
| September | 480.67 | 22.49 | 248.50 | 23.07 | 100.00 | 23.09 |
| October | 744.00 | 19.89 | 397.83 | 19.36 | 397.83 | 19.10 |
| November | 720.00 | 17.18 | 695.67 | 17.12 | 695.67 | 17.10 |
| December | 744.00 | 14.10 | 744.00 | 14.10 | 744.00 | 14.10 |
| Annual Sum or Average | 7515.67 | 18.78 | 6908.67 | 18.85 | 5933.17 | 18.57 |
| Minimum of Months | 427.67 | 13.58 | 248.50 | 13.58 | 100.00 | 13.58 |
| Maximum of Months | 744.00 | 25.78 | 744.00 | 25.78 | 744.00 | 25.84 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 20.83 | 131.83 | 20.81 | 131.83 | 20.80 |
| February | 672.00 | 21.29 | 100.83 | 21.33 | 100.83 | 21.36 |
| March | 744.00 | 21.82 | 438.33 | 21.90 | 438.33 | 21.94 |
| April | 688.17 | 23.06 | 468.00 | 23.24 | 462.67 | 23.31 |
| May | 744.00 | 25.32 | 744.00 | 25.32 | 744.00 | 25.32 |
| June | 720.00 | 25.89 | 720.00 | 25.89 | 720.00 | 25.89 |
| July | 744.00 | 26.05 | 744.00 | 26.05 | 744.00 | 26.05 |
| August | 744.00 | 25.83 | 744.00 | 25.83 | 744.00 | 25.83 |
| September | 720.00 | 25.09 | 720.00 | 25.09 | 720.00 | 25.09 |
| October | 744.00 | 22.99 | 722.33 | 23.01 | 722.33 | 23.02 |
| November | 720.00 | 21.64 | 323.17 | 21.72 | 323.17 | 21.77 |
| December | 744.00 | 20.82 | 90.00 | 20.81 | 90.00 | 20.79 |
| Annual Sum or Average | 8728.17 | 23.40 | 5946.50 | 23.82 | 5941.17 | 23.99 |
| Minimum of Months | 672.00 | 20.82 | 90.00 | 20.81 | 90.00 | 20.79 |
| Maximum of Months | 744.00 | 26.05 | 744.00 | 26.05 | 744.00 | 26.05 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 14908821.17 | 3908689.96 | 7.17 | 13883445.36 | 1025375.82 | 0.00 | 0.18 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 934.32 | 23-APR-16:10 | 868.28 | 23-APR-16:10 | 66.04 | 23-APR-16:10 | 247.38 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.436846E+09 | 0.113545E+09 | 204.37 | 0.410031E+09 | 26814338.33 | 0.00 | 0.37 | 25-MAY-17:40 | 0.00 | 01-MAY-00:10 | 2002.00 | 25-MAY-17:40 | 1828.45 | 18-MAY-16:10 | 269.44 | 26-MAY-12:00 | 534.83 | 25-MAY-17:40 | 0.00 | 01-MAY-00:10 |
| June | 0.134267E+10 | 0.342601E+09 | 408.10 | 0.110316E+10 | 0.239514E+09 | 0.00 | 0.57 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 3245.63 | 30-JUN-16:02 | 2542.95 | 29-JUN-16:05 | 735.03 | 30-JUN-16:02 | 886.66 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.266573E+10 | 0.668211E+09 | 686.85 | 0.216813E+10 | 0.497599E+09 | 0.00 | 0.55 | 23-JUL-16:05 | 0.00 | 02-JUL-01:30 | 3127.88 | 23-JUL-16:05 | 2552.24 | 29-JUL-16:07 | 913.86 | 15-JUL-14:30 | 807.39 | 23-JUL-16:05 | 0.00 | 01-JUL-00:10 |
| August | 0.215856E+10 | 0.538918E+09 | 656.07 | 0.181405E+10 | 0.344506E+09 | 0.00 | 0.52 | 08-AUG-16:04 | 0.00 | 01-AUG-07:25 | 2989.69 | 08-AUG-16:04 | 2432.31 | 25-AUG-16:04 | 633.31 | 31-AUG-13:30 | 782.25 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.726915E+09 | 0.185417E+09 | 327.84 | 0.682057E+09 | 44858008.84 | 0.00 | 0.45 | 01-SEP-16:04 | 0.00 | 01-SEP-06:00 | 2527.98 | 01-SEP-16:04 | 2364.28 | 01-SEP-16:04 | 343.41 | 01-SEP-11:00 | 633.40 | 01-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 76384713.66 | 19833597.74 | 45.17 | 76081508.62 | 303205.04 | 0.00 | 0.24 | 22-OCT-15:30 | 0.00 | 01-OCT-00:10 | 1282.27 | 22-OCT-15:30 | 1282.27 | 22-OCT-15:30 | 26.53 | 22-OCT-13:10 | 326.08 | 22-OCT-15:30 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.742202E+10 | 0.187243E+10 | 2335.57 | 0.626740E+10 | 0.115462E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.266573E+10 | 0.668211E+09 | 686.85 | 0.216813E+10 | 0.497599E+09 | 0.00 | 0.57 | 0.00 | 3245.63 | 2552.24 | 913.86 | 886.66 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 0.253586E+09 | 66117833.10 | 138.66 | 0.232123E+09 | 21462776.13 | 0.00 | 0.35 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 1737.72 | 25-MAY-18:00 | 1535.56 | 25-MAY-18:00 | 251.82 | 26-MAY-12:00 | 465.04 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.110155E+10 | 0.280661E+09 | 369.77 | 0.878178E+09 | 0.223375E+09 | 0.00 | 0.57 | 29-JUN-16:30 | 0.00 | 01-JUN-00:10 | 2930.85 | 29-JUN-16:30 | 2359.15 | 29-JUN-17:30 | 738.97 | 30-JUN-16:02 | 816.85 | 29-JUN-16:13 | 0.00 | 01-JUN-00:10 |
| July | 0.219109E+10 | 0.549225E+09 | 662.99 | 0.174121E+10 | 0.449876E+09 | 0.00 | 0.49 | 23-JUL-16:20 | 0.00 | 02-JUL-01:10 | 2579.74 | 23-JUL-16:30 | 2053.09 | 24-JUL-17:40 | 853.25 | 15-JUL-14:30 | 669.73 | 15-JUL-14:30 | 0.00 | 01-JUL-00:10 |
| August | 0.148859E+10 | 0.372538E+09 | 585.84 | 0.121147E+10 | 0.277121E+09 | 0.00 | 0.49 | 08-AUG-16:30 | 0.00 | 01-AUG-07:00 | 2544.14 | 08-AUG-16:30 | 1956.00 | 08-AUG-16:30 | 591.25 | 08-AUG-16:02 | 664.72 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.215080E+09 | 54855445.56 | 165.83 | 0.191797E+09 | 23282705.57 | 0.00 | 0.34 | 01-SEP-16:04 | 0.00 | 01-SEP-05:03 | 1733.47 | 01-SEP-16:15 | 1562.20 | 01-SEP-16:15 | 228.79 | 01-SEP-11:00 | 439.64 | 01-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.524990E+10 | 0.132340E+10 | 1923.10 | 0.425479E+10 | 0.995117E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.219109E+10 | 0.549225E+09 | 662.99 | 0.174121E+10 | 0.449876E+09 | 0.00 | 0.57 | 0.00 | 2930.85 | 2359.15 | 853.25 | 816.85 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 9392602.47 | 2506956.14 | 13.00 | 9392602.47 | -0.0 | 0.00 | 0.07 | 13-APR-15:00 | 0.00 | 01-APR-00:10 | 404.15 | 13-APR-15:00 | 404.15 | 13-APR-15:00 | 0.00 | 18-APR-13:40 | 107.96 | 13-APR-15:00 | 0.00 | 01-APR-00:10 |
| May | 0.564922E+09 | 0.143629E+09 | 127.18 | 0.529658E+09 | 35264634.16 | 0.00 | 1.00 | 17-MAY-08:62 | 0.00 | 01-MAY-00:10 | 7020.88 | 26-MAY-08:62 | 6730.36 | 24-MAY-08:62 | 1237.98 | 26-MAY-08:62 | 1513.38 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 |
| June | 0.150721E+10 | 0.374889E+09 | 196.03 | 0.130672E+10 | 0.200495E+09 | 0.00 | 1.00 | 06-JUN-08:62 | 0.00 | 01-JUN-00:10 | 7630.96 | 30-JUN-07:02 | 6691.39 | 08-JUN-08:62 | 3071.86 | 30-JUN-07:03 | 1569.88 | 30-JUN-08:62 | 0.00 | 01-JUN-00:10 |
| July | 0.207444E+10 | 0.503311E+09 | 213.17 | 0.178790E+10 | 0.286544E+09 | 0.00 | 1.00 | 03-JUL-07:02 | 0.00 | 01-JUL-00:10 | 7472.61 | 05-JUL-07:02 | 6514.97 | 06-JUL-07:02 | 2534.17 | 05-JUL-07:02 | 1522.10 | 25-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.197985E+10 | 0.479542E+09 | 218.01 | 0.168181E+10 | 0.298043E+09 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 7323.83 | 09-AUG-07:03 | 6468.44 | 02-AUG-08:62 | 2198.21 | 30-AUG-08:62 | 1518.73 | 30-AUG-08:62 | 0.00 | 01-AUG-00:10 |
| September | 0.775841E+09 | 0.193477E+09 | 148.80 | 0.734746E+09 | 41094121.11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 7219.45 | 01-SEP-07:02 | 6670.07 | 11-SEP-08:62 | 1950.58 | 01-SEP-07:02 | 1518.55 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 |
| October | 0.101445E+09 | 26412881.93 | 47.83 | 0.101097E+09 | 347345.14 | 0.00 | 0.27 | 20-OCT-14:30 | 0.00 | 01-OCT-00:10 | 1547.60 | 20-OCT-14:30 | 1547.60 | 20-OCT-14:30 | 24.86 | 02-OCT-13:00 | 396.05 | 20-OCT-14:30 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.701311E+10 | 0.172377E+10 | 964.02 | 0.615132E+10 | 0.861787E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.207444E+10 | 0.503311E+09 | 218.01 | 0.178790E+10 | 0.298043E+09 | 0.00 | 1.00 | 0.00 | 7630.96 | 6730.36 | 3071.86 | 1569.88 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 0.223841E+09 | 58314440.04 | 133.54 | 0.204492E+09 | 19348934.50 | 0.00 | 0.28 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 1223.77 | 25-MAY-18:00 | 1056.90 | 25-MAY-18:00 | 245.17 | 26-MAY-12:00 | 330.22 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.115275E+10 | 0.292536E+09 | 401.30 | 0.925639E+09 | 0.227114E+09 | 0.00 | 0.56 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 2535.95 | 29-JUN-16:02 | 1954.57 | 29-JUN-16:08 | 668.49 | 30-JUN-16:02 | 708.49 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.220924E+10 | 0.551417E+09 | 660.20 | 0.175668E+10 | 0.452555E+09 | 0.00 | 0.51 | 15-JUL-15:10 | 0.00 | 01-JUL-03:20 | 2414.40 | 15-JUL-15:10 | 1744.59 | 23-JUL-16:05 | 800.12 | 15-JUL-14:30 | 627.38 | 15-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.145573E+10 | 0.363340E+09 | 590.27 | 0.118226E+10 | 0.273479E+09 | 0.00 | 0.48 | 08-AUG-16:04 | 0.00 | 01-AUG-07:02 | 2234.58 | 08-AUG-16:04 | 1692.76 | 08-AUG-16:04 | 541.82 | 08-AUG-16:04 | 584.80 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.207019E+09 | 52727066.78 | 178.31 | 0.184324E+09 | 22695172.50 | 0.00 | 0.32 | 01-SEP-16:04 | 0.00 | 01-SEP-05:03 | 1406.07 | 01-SEP-16:04 | 1261.38 | 01-SEP-16:04 | 311.00 | 01-SEP-09:50 | 358.09 | 01-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.524858E+10 | 0.131833E+10 | 1963.62 | 0.425339E+10 | 0.995191E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.220924E+10 | 0.551417E+09 | 660.20 | 0.175668E+10 | 0.452555E+09 | 0.00 | 0.56 | 0.00 | 2535.95 | 1954.57 | 800.12 | 708.49 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 0.199911E+09 | 51946241.84 | 148.81 | 0.180780E+09 | 19130881.94 | 0.00 | 0.30 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 1175.34 | 25-MAY-18:00 | 1011.58 | 25-MAY-18:00 | 222.32 | 26-MAY-12:00 | 316.08 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.970429E+09 | 0.245939E+09 | 412.20 | 0.758474E+09 | 0.211955E+09 | 0.00 | 0.54 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 2174.50 | 29-JUN-16:02 | 1664.57 | 29-JUN-17:30 | 590.79 | 30-JUN-16:02 | 609.13 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.185006E+10 | 0.462191E+09 | 687.43 | 0.144332E+10 | 0.406735E+09 | 0.00 | 0.49 | 15-JUL-15:10 | 0.00 | 02-JUL-00:50 | 2051.16 | 15-JUL-15:10 | 1434.26 | 23-JUL-16:10 | 684.40 | 15-JUL-14:30 | 534.55 | 15-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.126083E+10 | 0.314916E+09 | 626.56 | 0.100809E+10 | 0.252741E+09 | 0.00 | 0.45 | 08-AUG-16:04 | 0.00 | 01-AUG-07:12 | 1852.59 | 08-AUG-16:04 | 1380.15 | 08-AUG-16:04 | 472.44 | 08-AUG-16:04 | 486.62 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.172565E+09 | 43834637.30 | 182.55 | 0.149130E+09 | 23435195.02 | 0.00 | 0.30 | 01-SEP-16:08 | 0.00 | 01-SEP-05:03 | 1194.06 | 01-SEP-16:08 | 1058.72 | 01-SEP-16:08 | 222.10 | 01-SEP-11:00 | 304.41 | 01-SEP-16:08 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.445379E+10 | 0.111883E+10 | 2057.54 | 0.353979E+10 | 0.913997E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.185006E+10 | 0.462191E+09 | 687.43 | 0.144332E+10 | 0.406735E+09 | 0.00 | 0.54 | 0.00 | 2174.50 | 1664.57 | 684.40 | 609.13 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
| May | 0.197798E+09 | 51403955.92 | 147.47 | 0.178869E+09 | 18928919.78 | 0.00 | 0.30 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 1160.15 | 25-MAY-18:00 | 997.76 | 25-MAY-18:00 | 221.49 | 26-MAY-12:00 | 312.12 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.977955E+09 | 0.247842E+09 | 416.05 | 0.765566E+09 | 0.212389E+09 | 0.00 | 0.54 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 2168.95 | 29-JUN-16:02 | 1656.42 | 29-JUN-17:30 | 589.10 | 30-JUN-16:02 | 607.57 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.184996E+10 | 0.462124E+09 | 686.58 | 0.144327E+10 | 0.406688E+09 | 0.00 | 0.49 | 15-JUL-15:10 | 0.00 | 02-JUL-00:50 | 2050.88 | 15-JUL-15:10 | 1429.36 | 23-JUL-16:10 | 684.04 | 15-JUL-14:30 | 534.40 | 15-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.126052E+10 | 0.314821E+09 | 627.32 | 0.100791E+10 | 0.252607E+09 | 0.00 | 0.45 | 08-AUG-16:04 | 0.00 | 01-AUG-07:12 | 1847.65 | 08-AUG-16:04 | 1376.45 | 08-AUG-16:04 | 471.19 | 08-AUG-16:04 | 485.32 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.173518E+09 | 44080343.95 | 185.57 | 0.150031E+09 | 23486940.15 | 0.00 | 0.30 | 01-SEP-16:08 | 0.00 | 01-SEP-05:03 | 1189.46 | 01-SEP-16:08 | 1054.77 | 01-SEP-16:08 | 224.13 | 01-SEP-11:00 | 303.26 | 01-SEP-16:08 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.445974E+10 | 0.112027E+10 | 2062.99 | 0.354564E+10 | 0.914100E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.184996E+10 | 0.462124E+09 | 686.58 | 0.144327E+10 | 0.406688E+09 | 0.00 | 0.54 | 0.00 | 2168.95 | 1656.42 | 684.04 | 607.57 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 8836426.41 | 2328606.84 | 6.83 | 8185554.58 | 650871.83 | 0.00 | 0.13 | 23-APR-16:03 | 0.00 | 01-APR-00:10 | 577.68 | 23-APR-16:03 | 534.70 | 23-APR-16:03 | 43.32 | 23-APR-16:10 | 153.87 | 23-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.387786E+09 | 0.100586E+09 | 226.10 | 0.361731E+09 | 26054873.00 | 0.00 | 0.33 | 25-MAY-16:05 | 0.00 | 01-MAY-00:10 | 1472.88 | 25-MAY-15:10 | 1357.30 | 18-MAY-15:10 | 243.55 | 26-MAY-11:00 | 392.69 | 25-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.123401E+10 | 0.313614E+09 | 458.10 | 0.100282E+10 | 0.231196E+09 | 0.00 | 0.54 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 | 2516.47 | 30-JUN-15:10 | 1932.22 | 30-JUN-15:10 | 596.08 | 30-JUN-16:02 | 680.95 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.234936E+10 | 0.587294E+09 | 714.22 | 0.188810E+10 | 0.461260E+09 | 0.00 | 0.52 | 23-JUL-13:30 | 0.00 | 02-JUL-01:30 | 2441.71 | 23-JUL-13:30 | 1951.20 | 23-JUL-15:10 | 757.65 | 15-JUL-14:20 | 634.37 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.196883E+10 | 0.490652E+09 | 698.09 | 0.164043E+10 | 0.328396E+09 | 0.00 | 0.50 | 08-AUG-15:10 | 0.00 | 03-AUG-10:00 | 2324.43 | 08-AUG-15:10 | 1879.92 | 25-AUG-15:10 | 556.23 | 31-AUG-13:30 | 611.76 | 08-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.748821E+09 | 0.190812E+09 | 402.68 | 0.698662E+09 | 50159411.61 | 0.00 | 0.44 | 01-SEP-15:10 | 0.00 | 05-SEP-03:50 | 2031.70 | 01-SEP-15:10 | 1864.05 | 01-SEP-15:10 | 334.12 | 01-SEP-11:00 | 510.84 | 01-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 89325360.03 | 23155433.15 | 62.97 | 88901713.47 | 423646.56 | 0.00 | 0.27 | 22-OCT-14:00 | 0.00 | 01-OCT-00:10 | 1212.10 | 22-OCT-14:00 | 1198.92 | 22-OCT-14:00 | 30.39 | 22-OCT-10:50 | 305.63 | 22-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.678697E+10 | 0.170844E+10 | 2568.99 | 0.568883E+10 | 0.109814E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.234936E+10 | 0.587294E+09 | 714.22 | 0.188810E+10 | 0.461260E+09 | 0.00 | 0.54 | 0.00 | 2516.47 | 1951.20 | 757.65 | 680.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 8523722.91 | 2247589.36 | 6.83 | 7892725.09 | 630997.81 | 0.00 | 0.13 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 566.40 | 23-APR-16:10 | 523.73 | 23-APR-16:10 | 42.67 | 23-APR-16:10 | 150.92 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.425829E+09 | 0.110288E+09 | 233.92 | 0.397732E+09 | 28096571.46 | 0.00 | 0.34 | 25-MAY-15:10 | 0.00 | 01-MAY-00:10 | 1523.32 | 25-MAY-15:10 | 1404.83 | 18-MAY-15:10 | 253.58 | 26-MAY-11:00 | 405.15 | 25-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.136163E+10 | 0.345395E+09 | 482.64 | 0.111489E+10 | 0.246737E+09 | 0.00 | 0.55 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 | 2597.06 | 30-JUN-15:10 | 2007.17 | 30-JUN-15:10 | 602.47 | 30-JUN-16:02 | 699.57 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.258942E+10 | 0.646162E+09 | 725.45 | 0.209871E+10 | 0.490709E+09 | 0.00 | 0.55 | 23-JUL-13:30 | 0.00 | 02-JUL-03:40 | 2603.05 | 23-JUL-13:30 | 2102.63 | 23-JUL-15:10 | 771.78 | 15-JUL-14:20 | 673.96 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.217841E+10 | 0.542235E+09 | 709.92 | 0.182571E+10 | 0.352702E+09 | 0.00 | 0.51 | 08-AUG-15:10 | 0.00 | 03-AUG-10:00 | 2400.75 | 08-AUG-15:10 | 1942.10 | 25-AUG-15:10 | 566.26 | 31-AUG-13:30 | 630.94 | 08-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.841661E+09 | 0.214240E+09 | 426.93 | 0.786742E+09 | 54919168.57 | 0.00 | 0.45 | 01-SEP-15:10 | 0.00 | 05-SEP-04:50 | 2098.87 | 01-SEP-15:10 | 1930.49 | 01-SEP-15:10 | 341.76 | 01-SEP-11:00 | 526.94 | 01-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 95327687.34 | 24709102.94 | 66.08 | 94888506.26 | 439181.08 | 0.00 | 0.28 | 22-OCT-14:00 | 0.00 | 01-OCT-00:10 | 1254.60 | 22-OCT-14:00 | 1241.21 | 22-OCT-14:00 | 31.27 | 22-OCT-10:50 | 315.98 | 22-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.750079E+10 | 0.188528E+10 | 2651.78 | 0.632656E+10 | 0.117423E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.258942E+10 | 0.646162E+09 | 725.45 | 0.209871E+10 | 0.490709E+09 | 0.00 | 0.55 | 0.00 | 2603.05 | 2102.63 | 771.78 | 699.57 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 1271940.30 | 340552.72 | 2.06 | 1271940.30 | -0.0 | 0.00 | 0.03 | 19-MAR-16:30 | 0.00 | 01-MAR-00:10 | 332.55 | 19-MAR-16:30 | 332.55 | 19-MAR-16:30 | 0.00 | 19-MAR-16:01 | 88.95 | 19-MAR-16:30 | 0.00 | 01-MAR-00:10 |
| April | 0.498933E+09 | 0.130347E+09 | 105.33 | 0.493157E+09 | 5775817.43 | 0.00 | 0.41 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 5665.86 | 23-APR-16:10 | 5409.93 | 23-APR-16:07 | 257.95 | 23-APR-16:30 | 1450.15 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.307263E+10 | 0.791722E+09 | 466.76 | 0.297398E+10 | 98643651.49 | 0.00 | 0.46 | 25-MAY-17:30 | 0.00 | 01-MAY-00:10 | 6321.65 | 25-MAY-17:30 | 6001.38 | 18-MAY-16:03 | 789.94 | 26-MAY-11:00 | 1667.99 | 25-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.525496E+10 | 0.133522E+10 | 616.52 | 0.454742E+10 | 0.707538E+09 | 0.00 | 0.60 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 8440.91 | 30-JUN-16:02 | 6831.98 | 29-JUN-16:05 | 1741.21 | 30-JUN-16:02 | 2317.14 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.729309E+10 | 0.182950E+10 | 728.21 | 0.607087E+10 | 0.122222E+10 | 0.00 | 0.55 | 23-JUL-16:05 | 0.00 | 02-JUL-03:30 | 7881.94 | 23-JUL-16:05 | 6713.90 | 29-JUL-16:10 | 2195.49 | 15-JUL-14:30 | 2036.44 | 23-JUL-16:05 | 0.00 | 01-JUL-00:10 |
| August | 0.553056E+10 | 0.138252E+10 | 678.57 | 0.471226E+10 | 0.818303E+09 | 0.00 | 0.53 | 08-AUG-16:04 | 0.00 | 02-AUG-04:20 | 7466.45 | 08-AUG-16:04 | 6134.01 | 25-AUG-16:04 | 1580.63 | 31-AUG-13:30 | 1956.48 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.213613E+10 | 0.544723E+09 | 377.95 | 0.201560E+10 | 0.120535E+09 | 0.00 | 0.48 | 01-SEP-15:30 | 0.00 | 03-SEP-08:35 | 6646.09 | 01-SEP-15:30 | 6236.61 | 01-SEP-15:30 | 855.17 | 01-SEP-11:00 | 1666.83 | 01-SEP-15:30 | 0.00 | 01-SEP-00:10 |
| October | 0.457782E+09 | 0.118169E+09 | 83.17 | 0.456672E+09 | 1110026.34 | 0.00 | 0.31 | 22-OCT-15:30 | 0.00 | 01-OCT-00:10 | 4201.83 | 22-OCT-15:30 | 4201.83 | 22-OCT-15:30 | 76.63 | 22-OCT-13:00 | 1056.85 | 22-OCT-15:30 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.242454E+11 | 0.613254E+10 | 3058.56 | 0.212712E+11 | 0.297412E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.729309E+10 | 0.182950E+10 | 728.21 | 0.607087E+10 | 0.122222E+10 | 0.00 | 0.60 | 0.00 | 8440.91 | 6831.98 | 2195.49 | 2317.14 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 56463819.62 | 14679293.53 | 9.83 | 53480067.99 | 2983751.64 | 0.00 | 0.24 | 23-APR-17:30 | 0.00 | 01-APR-00:10 | 3036.27 | 23-APR-17:30 | 2858.35 | 23-APR-17:30 | 179.25 | 23-APR-18:00 | 788.16 | 23-APR-17:30 | 0.00 | 01-APR-00:10 |
| May | 0.216589E+10 | 0.559028E+09 | 390.63 | 0.207110E+10 | 94791488.44 | 0.00 | 0.46 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 5933.64 | 25-MAY-18:00 | 5455.57 | 25-MAY-18:00 | 718.65 | 26-MAY-12:00 | 1567.28 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.465590E+10 | 0.118337E+10 | 607.61 | 0.396924E+10 | 0.686664E+09 | 0.00 | 0.59 | 29-JUN-16:13 | 0.00 | 01-JUN-00:10 | 7784.28 | 29-JUN-16:13 | 6372.11 | 29-JUN-17:30 | 1767.93 | 30-JUN-16:02 | 2168.75 | 29-JUN-16:13 | 0.00 | 01-JUN-00:10 |
| July | 0.629160E+10 | 0.157989E+10 | 725.30 | 0.514452E+10 | 0.114708E+10 | 0.00 | 0.49 | 23-JUL-16:20 | 0.00 | 02-JUL-03:30 | 6621.44 | 15-JUL-14:30 | 5449.88 | 24-JUL-17:30 | 2067.96 | 15-JUL-14:30 | 1735.75 | 15-JUL-14:30 | 0.00 | 01-JUL-00:10 |
| August | 0.411460E+10 | 0.103238E+10 | 652.18 | 0.341212E+10 | 0.702479E+09 | 0.00 | 0.48 | 08-AUG-16:12 | 0.00 | 01-AUG-07:40 | 6433.70 | 08-AUG-16:12 | 5047.39 | 08-AUG-16:30 | 1389.69 | 08-AUG-16:02 | 1687.44 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.772031E+09 | 0.197243E+09 | 236.06 | 0.693164E+09 | 78867120.43 | 0.00 | 0.35 | 01-SEP-16:04 | 0.00 | 01-SEP-06:00 | 4520.95 | 01-SEP-16:12 | 4135.90 | 01-SEP-16:20 | 540.43 | 01-SEP-11:00 | 1148.34 | 01-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.180565E+11 | 0.456660E+10 | 2621.62 | 0.153436E+11 | 0.271287E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.629160E+10 | 0.157989E+10 | 725.30 | 0.514452E+10 | 0.114708E+10 | 0.00 | 0.59 | 0.00 | 7784.28 | 6372.11 | 2067.96 | 2168.75 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.474887E+09 | 0.124283E+09 | 112.83 | 0.469946E+09 | 4941005.46 | 0.00 | 0.35 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 4136.76 | 23-APR-16:10 | 3942.21 | 23-APR-15:20 | 211.73 | 23-APR-16:10 | 1068.01 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.293859E+10 | 0.755027E+09 | 474.03 | 0.284156E+10 | 97025150.29 | 0.00 | 0.47 | 18-MAY-13:30 | 0.00 | 01-MAY-00:10 | 5513.16 | 18-MAY-13:00 | 5492.66 | 18-MAY-13:30 | 806.77 | 26-MAY-11:00 | 1441.07 | 18-MAY-13:30 | 0.00 | 01-MAY-00:10 |
| June | 0.545927E+10 | 0.137913E+10 | 625.45 | 0.474541E+10 | 0.713869E+09 | 0.00 | 0.60 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 | 7415.70 | 30-JUN-15:10 | 5851.72 | 30-JUN-14:30 | 1581.58 | 30-JUN-15:20 | 1967.77 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.734564E+10 | 0.183094E+10 | 724.12 | 0.611412E+10 | 0.123151E+10 | 0.00 | 0.58 | 23-JUL-13:30 | 0.00 | 02-JUL-03:00 | 7175.57 | 23-JUL-13:30 | 5959.34 | 23-JUL-13:30 | 2052.92 | 15-JUL-14:20 | 1854.63 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.546655E+10 | 0.135978E+10 | 676.79 | 0.465031E+10 | 0.816236E+09 | 0.00 | 0.54 | 08-AUG-14:10 | 0.00 | 02-AUG-02:50 | 6676.63 | 08-AUG-14:10 | 5510.73 | 25-AUG-14:10 | 1509.53 | 31-AUG-13:00 | 1742.95 | 08-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.213840E+10 | 0.543622E+09 | 384.66 | 0.202162E+10 | 0.116779E+09 | 0.00 | 0.49 | 01-SEP-13:30 | 0.00 | 03-SEP-08:35 | 6044.55 | 01-SEP-12:40 | 5472.67 | 01-SEP-13:30 | 1021.77 | 01-SEP-09:40 | 1472.22 | 01-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 0.442611E+09 | 0.113827E+09 | 81.56 | 0.441224E+09 | 1387235.77 | 0.00 | 0.34 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 | 4014.75 | 22-OCT-13:30 | 3962.91 | 22-OCT-13:40 | 95.36 | 22-OCT-10:20 | 1000.98 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.242659E+11 | 0.610661E+10 | 3079.43 | 0.212842E+11 | 0.298175E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.734564E+10 | 0.183094E+10 | 724.12 | 0.611412E+10 | 0.123151E+10 | 0.00 | 0.60 | 0.00 | 7415.70 | 5959.34 | 2052.92 | 1967.77 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 29020309.57 | 7615623.12 | 9.00 | 27201145.02 | 1819164.55 | 0.00 | 0.14 | 23-APR-18:00 | 0.00 | 01-APR-00:10 | 1546.22 | 23-APR-18:00 | 1432.42 | 23-APR-18:00 | 113.80 | 23-APR-18:00 | 404.91 | 23-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.201135E+10 | 0.517625E+09 | 409.97 | 0.191861E+10 | 92737181.72 | 0.00 | 0.38 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 4149.30 | 25-MAY-18:00 | 3761.30 | 18-MAY-16:03 | 730.55 | 26-MAY-11:00 | 1107.31 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.486184E+10 | 0.122929E+10 | 615.03 | 0.416832E+10 | 0.693522E+09 | 0.00 | 0.57 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 6385.93 | 29-JUN-16:02 | 5036.44 | 29-JUN-16:05 | 1576.07 | 30-JUN-16:02 | 1785.24 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.634609E+10 | 0.158421E+10 | 717.17 | 0.518947E+10 | 0.115662E+10 | 0.00 | 0.51 | 15-JUL-14:30 | 0.00 | 02-JUL-02:70 | 5993.95 | 15-JUL-14:30 | 4358.18 | 23-JUL-16:10 | 1899.14 | 15-JUL-14:30 | 1563.37 | 15-JUL-14:30 | 0.00 | 01-JUL-00:10 |
| August | 0.404858E+10 | 0.101234E+10 | 650.81 | 0.334887E+10 | 0.699708E+09 | 0.00 | 0.47 | 08-AUG-16:04 | 0.00 | 02-AUG-02:70 | 5396.30 | 08-AUG-16:04 | 4144.17 | 08-AUG-16:04 | 1252.14 | 08-AUG-16:04 | 1417.15 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.754166E+09 | 0.192617E+09 | 255.96 | 0.678143E+09 | 76022945.17 | 0.00 | 0.31 | 01-SEP-11:00 | 0.00 | 01-SEP-05:40 | 3564.81 | 01-SEP-11:00 | 3063.60 | 01-SEP-16:04 | 784.24 | 01-SEP-09:30 | 868.38 | 01-SEP-11:00 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.180510E+11 | 0.454369E+10 | 2657.93 | 0.153306E+11 | 0.272043E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.634609E+10 | 0.158421E+10 | 717.17 | 0.518947E+10 | 0.115662E+10 | 0.00 | 0.57 | 0.00 | 6385.93 | 5036.44 | 1899.14 | 1785.24 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 17595638.90 | 4634002.69 | 8.00 | 16383370.44 | 1212268.46 | 0.00 | 0.12 | 23-APR-18:00 | 0.00 | 01-APR-00:10 | 1129.93 | 23-APR-18:00 | 1040.35 | 23-APR-18:00 | 89.58 | 23-APR-18:00 | 296.84 | 23-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.160145E+10 | 0.413257E+09 | 401.71 | 0.151931E+10 | 82138055.41 | 0.00 | 0.37 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 3640.42 | 25-MAY-18:00 | 3245.59 | 25-MAY-18:00 | 613.67 | 26-MAY-11:10 | 971.79 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.378975E+10 | 0.961111E+09 | 661.63 | 0.317785E+10 | 0.611894E+09 | 0.00 | 0.52 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 5217.70 | 29-JUN-16:02 | 4073.37 | 29-JUN-18:00 | 1333.17 | 30-JUN-16:02 | 1468.15 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.499601E+10 | 0.125121E+10 | 734.00 | 0.399865E+10 | 0.997357E+09 | 0.00 | 0.47 | 15-JUL-15:10 | 0.00 | 02-JUL-03:40 | 4876.39 | 15-JUL-15:10 | 3399.54 | 23-JUL-16:10 | 1561.87 | 15-JUL-14:30 | 1277.81 | 15-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.337224E+10 | 0.844934E+09 | 697.66 | 0.274563E+10 | 0.626610E+09 | 0.00 | 0.42 | 08-AUG-16:04 | 0.00 | 01-AUG-08:00 | 4313.24 | 08-AUG-16:04 | 3258.44 | 08-AUG-16:04 | 1054.80 | 08-AUG-16:04 | 1139.41 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.656342E+09 | 0.167287E+09 | 283.10 | 0.573222E+09 | 83120241.46 | 0.00 | 0.28 | 01-SEP-16:08 | 0.00 | 02-SEP-08:20 | 2755.13 | 01-SEP-16:08 | 2464.00 | 01-SEP-16:08 | 506.48 | 01-SEP-11:00 | 705.40 | 01-SEP-16:08 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.144334E+11 | 0.364243E+10 | 2786.10 | 0.120310E+11 | 0.240233E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.499601E+10 | 0.125121E+10 | 734.00 | 0.399865E+10 | 0.997357E+09 | 0.00 | 0.52 | 0.00 | 5217.70 | 4073.37 | 1561.87 | 1468.15 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 17171125.32 | 4523690.88 | 8.00 | 15981591.67 | 1189533.65 | 0.00 | 0.12 | 23-APR-18:00 | 0.00 | 01-APR-00:10 | 1105.33 | 23-APR-18:00 | 1017.41 | 23-APR-18:00 | 87.92 | 23-APR-18:00 | 290.46 | 23-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.159940E+10 | 0.412715E+09 | 402.04 | 0.151740E+10 | 82003980.52 | 0.00 | 0.37 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 3604.39 | 25-MAY-18:00 | 3211.71 | 25-MAY-18:00 | 613.61 | 26-MAY-11:10 | 962.48 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.379949E+10 | 0.963498E+09 | 661.80 | 0.318750E+10 | 0.611989E+09 | 0.00 | 0.52 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 5198.99 | 29-JUN-16:02 | 4047.62 | 29-JUN-16:05 | 1329.31 | 30-JUN-16:02 | 1462.91 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.499723E+10 | 0.125138E+10 | 733.33 | 0.399989E+10 | 0.997345E+09 | 0.00 | 0.47 | 15-JUL-15:10 | 0.00 | 02-JUL-03:40 | 4869.43 | 15-JUL-15:10 | 3389.28 | 23-JUL-16:10 | 1560.17 | 15-JUL-14:30 | 1275.84 | 15-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.337115E+10 | 0.844606E+09 | 696.65 | 0.274491E+10 | 0.626240E+09 | 0.00 | 0.42 | 08-AUG-16:04 | 0.00 | 01-AUG-10:00 | 4301.03 | 08-AUG-16:04 | 3249.23 | 08-AUG-16:04 | 1051.80 | 08-AUG-16:04 | 1136.17 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.660240E+09 | 0.168302E+09 | 285.34 | 0.577151E+09 | 83089019.95 | 0.00 | 0.28 | 01-SEP-16:08 | 0.00 | 02-SEP-08:20 | 2742.42 | 01-SEP-16:08 | 2452.91 | 01-SEP-16:08 | 511.95 | 01-SEP-11:00 | 702.20 | 01-SEP-16:08 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.144447E+11 | 0.364503E+10 | 2787.17 | 0.120428E+11 | 0.240186E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.499723E+10 | 0.125138E+10 | 733.33 | 0.399989E+10 | 0.997345E+09 | 0.00 | 0.52 | 0.00 | 5198.99 | 4047.62 | 1560.17 | 1462.91 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.381937E+09 | 0.100019E+09 | 115.67 | 0.377292E+09 | 4645128.33 | 0.00 | 0.36 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 3816.41 | 23-APR-16:10 | 3640.81 | 23-APR-15:20 | 189.38 | 23-APR-16:10 | 984.92 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.249511E+10 | 0.643553E+09 | 498.10 | 0.240782E+10 | 87292051.14 | 0.00 | 0.42 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 | 4446.68 | 18-MAY-13:40 | 4430.69 | 18-MAY-13:40 | 687.14 | 26-MAY-11:00 | 1173.15 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.439393E+10 | 0.111453E+10 | 672.42 | 0.375757E+10 | 0.636362E+09 | 0.00 | 0.55 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 | 6086.28 | 30-JUN-15:10 | 4773.21 | 30-JUN-15:10 | 1331.01 | 30-JUN-16:02 | 1630.55 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.601177E+10 | 0.150448E+10 | 739.10 | 0.492750E+10 | 0.108426E+10 | 0.00 | 0.53 | 23-JUL-13:30 | 0.00 | 02-JUL-03:50 | 5916.46 | 23-JUL-13:30 | 4811.24 | 23-JUL-13:30 | 1725.69 | 15-JUL-14:20 | 1539.19 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.481417E+10 | 0.120123E+10 | 715.56 | 0.405997E+10 | 0.754199E+09 | 0.00 | 0.50 | 08-AUG-15:10 | 0.00 | 03-AUG-10:00 | 5501.54 | 08-AUG-15:10 | 4571.09 | 25-AUG-14:10 | 1386.33 | 31-AUG-13:00 | 1451.06 | 08-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.212307E+10 | 0.540832E+09 | 453.73 | 0.199434E+10 | 0.128730E+09 | 0.00 | 0.47 | 01-SEP-13:30 | 0.00 | 05-SEP-03:30 | 5182.68 | 01-SEP-13:30 | 4678.06 | 01-SEP-13:40 | 818.39 | 01-SEP-10:50 | 1273.66 | 01-SEP-13:40 | 0.00 | 01-SEP-00:10 |
| October | 0.514618E+09 | 0.132360E+09 | 109.25 | 0.513251E+09 | 1366683.21 | 0.00 | 0.37 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 | 3946.22 | 22-OCT-13:40 | 3892.92 | 22-OCT-13:40 | 90.65 | 22-OCT-10:30 | 980.20 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.207346E+11 | 0.523700E+10 | 3303.82 | 0.180377E+11 | 0.269686E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.601177E+10 | 0.150448E+10 | 739.10 | 0.492750E+10 | 0.108426E+10 | 0.00 | 0.55 | 0.00 | 6086.28 | 4811.24 | 1725.69 | 1630.55 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.389410E+09 | 0.101983E+09 | 116.50 | 0.384783E+09 | 4627563.51 | 0.00 | 0.36 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 3796.15 | 23-APR-16:10 | 3630.32 | 23-APR-15:20 | 188.62 | 23-APR-16:10 | 979.80 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.249489E+10 | 0.643455E+09 | 498.78 | 0.240772E+10 | 87172746.44 | 0.00 | 0.42 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 | 4460.30 | 18-MAY-13:30 | 4442.96 | 18-MAY-13:40 | 687.03 | 26-MAY-11:00 | 1175.93 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.440385E+10 | 0.111689E+10 | 672.10 | 0.376743E+10 | 0.636415E+09 | 0.00 | 0.55 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 | 6074.28 | 30-JUN-15:10 | 4769.37 | 30-JUN-14:30 | 1327.92 | 30-JUN-16:02 | 1628.25 | 29-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.601326E+10 | 0.150464E+10 | 738.39 | 0.492906E+10 | 0.108420E+10 | 0.00 | 0.53 | 23-JUL-13:30 | 0.00 | 02-JUL-03:50 | 5927.89 | 23-JUL-13:30 | 4823.20 | 23-JUL-13:30 | 1724.35 | 15-JUL-14:20 | 1541.62 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.481301E+10 | 0.120078E+10 | 715.75 | 0.405922E+10 | 0.753789E+09 | 0.00 | 0.50 | 08-AUG-15:10 | 0.00 | 03-AUG-10:00 | 5499.85 | 08-AUG-14:10 | 4582.75 | 25-AUG-14:10 | 1386.03 | 31-AUG-13:00 | 1450.10 | 08-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.212481E+10 | 0.541218E+09 | 454.20 | 0.199626E+10 | 0.128546E+09 | 0.00 | 0.47 | 01-SEP-13:30 | 0.00 | 05-SEP-03:30 | 5197.92 | 01-SEP-13:30 | 4692.16 | 01-SEP-13:40 | 821.49 | 01-SEP-10:50 | 1276.63 | 01-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 0.513945E+09 | 0.132163E+09 | 108.67 | 0.512570E+09 | 1374166.71 | 0.00 | 0.37 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 | 3956.22 | 22-OCT-13:40 | 3902.92 | 22-OCT-13:40 | 91.18 | 22-OCT-10:30 | 982.38 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.207532E+11 | 0.524113E+10 | 3304.39 | 0.180570E+11 | 0.269613E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.601326E+10 | 0.150464E+10 | 738.39 | 0.492906E+10 | 0.108420E+10 | 0.00 | 0.55 | 0.00 | 6074.28 | 4823.20 | 1724.35 | 1628.25 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 2508428.87 | 671813.97 | 3.33 | 2508428.87 | 0.00 | 0.00 | 0.07 | 28-FEB-15:30 | 0.00 | 01-FEB-00:10 | 441.86 | 28-FEB-15:30 | 441.86 | 28-FEB-15:30 | 0.00 | 28-FEB-15:30 | 117.87 | 28-FEB-15:30 | 0.00 | 01-FEB-00:10 |
| March | 44870784.90 | 11858347.51 | 21.88 | 44870784.90 | 0.00 | 0.00 | 0.19 | 26-MAR-16:06 | 0.00 | 01-MAR-00:10 | 1328.88 | 26-MAR-16:06 | 1328.88 | 26-MAR-16:06 | 0.00 | 26-MAR-15:40 | 346.07 | 26-MAR-16:06 | 0.00 | 01-MAR-00:10 |
| April | 0.371069E+09 | 96427738.80 | 102.00 | 0.367867E+09 | 3202008.19 | 0.00 | 0.47 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 3542.91 | 23-APR-16:10 | 3392.24 | 23-APR-16:03 | 151.37 | 23-APR-16:30 | 898.71 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.151775E+10 | 0.389242E+09 | 330.65 | 0.147150E+10 | 46244370.12 | 0.00 | 0.53 | 18-MAY-15:20 | 0.00 | 01-MAY-00:10 | 3989.84 | 25-MAY-16:12 | 3925.05 | 18-MAY-15:20 | 463.02 | 26-MAY-11:00 | 1039.65 | 25-MAY-17:20 | 0.00 | 01-MAY-00:10 |
| June | 0.258148E+10 | 0.654030E+09 | 443.36 | 0.224788E+10 | 0.333600E+09 | 0.00 | 0.69 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 5342.22 | 30-JUN-16:02 | 4430.31 | 29-JUN-16:03 | 1003.87 | 30-JUN-16:02 | 1453.69 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.360793E+10 | 0.902077E+09 | 567.65 | 0.302909E+10 | 0.578840E+09 | 0.00 | 0.64 | 29-JUL-16:10 | 0.00 | 01-JUL-02:30 | 4993.31 | 23-JUL-16:05 | 4403.14 | 29-JUL-16:07 | 1303.60 | 15-JUL-14:30 | 1275.00 | 23-JUL-15:40 | 0.00 | 01-JUL-00:10 |
| August | 0.258014E+10 | 0.641235E+09 | 455.56 | 0.222064E+10 | 0.359502E+09 | 0.00 | 0.62 | 08-AUG-15:30 | 0.00 | 01-AUG-05:05 | 4830.51 | 08-AUG-15:30 | 4010.70 | 08-AUG-15:30 | 969.91 | 31-AUG-13:30 | 1253.02 | 08-AUG-15:30 | 0.00 | 01-AUG-00:10 |
| September | 0.885893E+09 | 0.224777E+09 | 218.64 | 0.843090E+09 | 42803033.09 | 0.00 | 0.56 | 01-SEP-15:30 | 0.00 | 01-SEP-05:03 | 4310.66 | 01-SEP-15:30 | 4084.77 | 01-SEP-15:30 | 525.62 | 01-SEP-11:00 | 1067.52 | 01-SEP-15:30 | 0.00 | 01-SEP-00:10 |
| October | 0.258766E+09 | 66586167.26 | 74.18 | 0.258378E+09 | 388310.80 | 0.00 | 0.34 | 19-OCT-15:10 | 0.00 | 01-OCT-00:10 | 2516.93 | 19-OCT-15:10 | 2516.93 | 19-OCT-15:10 | 41.02 | 22-OCT-13:00 | 631.00 | 19-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.118504E+11 | 0.298690E+10 | 2217.24 | 0.104858E+11 | 0.136458E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.360793E+10 | 0.902077E+09 | 567.65 | 0.302909E+10 | 0.578840E+09 | 0.00 | 0.69 | 0.00 | 5342.22 | 4430.31 | 1303.60 | 1453.69 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 75711695.42 | 19757556.68 | 33.79 | 73609332.99 | 2102362.43 | 0.00 | 0.33 | 23-APR-17:15 | 0.00 | 01-APR-00:10 | 2391.66 | 23-APR-17:15 | 2274.84 | 23-APR-17:15 | 118.03 | 23-APR-17:40 | 613.33 | 23-APR-17:15 | 0.00 | 01-APR-00:10 |
| May | 0.107334E+10 | 0.276480E+09 | 287.03 | 0.102846E+10 | 44882118.46 | 0.00 | 0.51 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 3740.00 | 25-MAY-18:00 | 3483.79 | 25-MAY-18:00 | 415.34 | 26-MAY-11:10 | 980.39 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.225666E+10 | 0.573142E+09 | 443.59 | 0.192982E+10 | 0.326847E+09 | 0.00 | 0.67 | 29-JUN-16:13 | 0.00 | 01-JUN-00:10 | 4961.61 | 29-JUN-16:13 | 4125.94 | 29-JUN-17:30 | 1024.14 | 30-JUN-16:02 | 1367.23 | 29-JUN-16:13 | 0.00 | 01-JUN-00:10 |
| July | 0.307792E+10 | 0.772289E+09 | 568.92 | 0.253153E+10 | 0.546383E+09 | 0.00 | 0.56 | 23-JUL-16:30 | 0.00 | 01-JUL-02:30 | 4234.68 | 23-JUL-16:30 | 3565.61 | 29-JUL-16:40 | 1236.82 | 15-JUL-14:30 | 1086.96 | 23-JUL-16:05 | 0.00 | 01-JUL-00:10 |
| August | 0.186981E+10 | 0.468118E+09 | 432.74 | 0.156295E+10 | 0.306854E+09 | 0.00 | 0.55 | 08-AUG-16:12 | 0.00 | 01-AUG-05:05 | 4157.61 | 08-AUG-16:12 | 3345.32 | 08-AUG-16:15 | 815.24 | 08-AUG-15:30 | 1081.22 | 08-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.277310E+09 | 70675036.16 | 124.29 | 0.250623E+09 | 26686733.35 | 0.00 | 0.40 | 01-SEP-16:15 | 0.00 | 01-SEP-05:03 | 2933.42 | 01-SEP-16:15 | 2716.75 | 01-SEP-16:15 | 315.94 | 01-SEP-11:40 | 739.09 | 01-SEP-16:02 | 0.00 | 01-SEP-00:10 |
| October | 3998690.03 | 1051576.00 | 6.92 | 3998690.03 | -0.0 | 0.00 | 0.07 | 19-OCT-16:10 | 0.00 | 01-OCT-00:10 | 461.62 | 19-OCT-16:10 | 461.62 | 19-OCT-16:10 | 0.00 | 19-OCT-16:50 | 120.76 | 19-OCT-16:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.863474E+10 | 0.218151E+10 | 1897.28 | 0.738099E+10 | 0.125375E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.307792E+10 | 0.772289E+09 | 568.92 | 0.253153E+10 | 0.546383E+09 | 0.00 | 0.67 | 0.00 | 4961.61 | 4125.94 | 1236.82 | 1367.23 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 15383800.66 | 4093643.83 | 15.25 | 15383800.66 | 0.00 | 0.00 | 0.12 | 26-MAR-15:10 | 0.00 | 01-MAR-00:10 | 664.07 | 26-MAR-15:10 | 664.07 | 26-MAR-15:10 | 0.00 | 26-MAR-16:20 | 174.98 | 26-MAR-15:10 | 0.00 | 01-MAR-00:10 |
| April | 0.323740E+09 | 84220112.27 | 107.67 | 0.321043E+09 | 2697159.14 | 0.00 | 0.41 | 23-APR-15:30 | 0.00 | 01-APR-00:10 | 2510.43 | 23-APR-15:30 | 2407.58 | 23-APR-15:20 | 123.58 | 23-APR-14:00 | 638.38 | 23-APR-15:30 | 0.00 | 01-APR-00:10 |
| May | 0.140709E+10 | 0.358973E+09 | 347.30 | 0.136119E+10 | 45902602.91 | 0.00 | 0.59 | 18-MAY-13:30 | 0.00 | 01-MAY-00:10 | 3601.17 | 18-MAY-13:30 | 3591.62 | 18-MAY-13:30 | 485.82 | 26-MAY-11:00 | 924.10 | 18-MAY-13:30 | 0.00 | 01-MAY-00:10 |
| June | 0.264360E+10 | 0.663536E+09 | 483.79 | 0.230521E+10 | 0.338391E+09 | 0.00 | 0.74 | 30-JUN-13:20 | 0.00 | 01-JUN-00:10 | 4781.21 | 30-JUN-13:20 | 3898.94 | 30-JUN-13:20 | 930.70 | 30-JUN-15:20 | 1233.42 | 30-JUN-13:00 | 0.00 | 01-JUN-00:10 |
| July | 0.363800E+10 | 0.900456E+09 | 589.93 | 0.304980E+10 | 0.588199E+09 | 0.00 | 0.72 | 23-JUL-13:30 | 0.00 | 01-JUL-02:00 | 4640.46 | 23-JUL-13:30 | 3954.60 | 23-JUL-13:30 | 1213.23 | 15-JUL-14:20 | 1175.71 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.252896E+10 | 0.623293E+09 | 472.42 | 0.216988E+10 | 0.359081E+09 | 0.00 | 0.68 | 08-AUG-14:10 | 0.00 | 01-AUG-05:05 | 4341.53 | 08-AUG-14:10 | 3606.56 | 08-AUG-14:10 | 924.11 | 30-AUG-09:40 | 1106.70 | 08-AUG-14:10 | 0.00 | 01-AUG-00:10 |
| September | 0.871776E+09 | 0.220185E+09 | 227.76 | 0.830642E+09 | 41133293.58 | 0.00 | 0.62 | 01-SEP-13:30 | 0.00 | 01-SEP-05:03 | 3939.62 | 01-SEP-12:40 | 3617.10 | 01-SEP-13:30 | 625.53 | 01-SEP-09:40 | 942.94 | 01-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 0.250583E+09 | 64240319.89 | 74.42 | 0.250012E+09 | 570528.97 | 0.00 | 0.38 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 | 2280.38 | 22-OCT-13:40 | 2254.09 | 22-OCT-13:40 | 42.78 | 22-OCT-12:40 | 565.77 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.116791E+11 | 0.291900E+10 | 2318.54 | 0.103032E+11 | 0.137597E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.363800E+10 | 0.900456E+09 | 589.93 | 0.304980E+10 | 0.588199E+09 | 0.00 | 0.74 | 0.00 | 4781.21 | 3954.60 | 1213.23 | 1233.42 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 28707678.52 | 7480032.22 | 16.28 | 27249215.30 | 1458463.22 | 0.00 | 0.23 | 23-APR-16:15 | 0.00 | 01-APR-00:10 | 1296.03 | 23-APR-16:15 | 1219.60 | 23-APR-16:15 | 81.32 | 23-APR-18:00 | 340.38 | 23-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.948344E+09 | 0.243018E+09 | 292.61 | 0.903916E+09 | 44428608.79 | 0.00 | 0.43 | 25-MAY-16:05 | 0.00 | 01-MAY-00:10 | 2520.73 | 25-MAY-16:05 | 2344.73 | 18-MAY-16:10 | 435.23 | 26-MAY-11:00 | 664.18 | 25-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.232317E+10 | 0.585602E+09 | 483.87 | 0.199050E+10 | 0.332674E+09 | 0.00 | 0.66 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 3989.80 | 29-JUN-16:02 | 3208.83 | 29-JUN-16:03 | 914.75 | 30-JUN-15:30 | 1099.94 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.311829E+10 | 0.775925E+09 | 591.86 | 0.256071E+10 | 0.557582E+09 | 0.00 | 0.59 | 15-JUL-14:40 | 0.00 | 01-JUL-01:50 | 3669.90 | 15-JUL-14:40 | 2801.22 | 23-JUL-15:10 | 1129.62 | 15-JUL-14:30 | 947.49 | 15-JUL-14:40 | 0.00 | 01-JUL-00:10 |
| August | 0.181044E+10 | 0.450979E+09 | 446.94 | 0.150456E+10 | 0.305887E+09 | 0.00 | 0.55 | 08-AUG-16:04 | 0.00 | 01-AUG-05:00 | 3382.45 | 08-AUG-16:04 | 2654.16 | 08-AUG-16:04 | 728.65 | 30-AUG-09:40 | 878.71 | 08-AUG-16:04 | 0.00 | 01-AUG-00:10 |
| September | 0.225191E+09 | 57079141.16 | 125.45 | 0.200219E+09 | 24972207.33 | 0.00 | 0.37 | 01-SEP-11:00 | 0.00 | 01-SEP-05:03 | 2215.03 | 01-SEP-11:00 | 1901.61 | 01-SEP-16:04 | 467.30 | 01-SEP-09:40 | 535.56 | 01-SEP-11:00 | 0.00 | 01-SEP-00:10 |
| October | 94986.47 | 25071.85 | 0.67 | 94986.47 | -0.0 | 0.00 | 0.01 | 19-OCT-16:05 | 0.00 | 01-OCT-00:10 | 64.15 | 19-OCT-16:05 | 64.15 | 19-OCT-16:05 | 0.00 | 19-OCT-16:10 | 16.92 | 19-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.845425E+10 | 0.212011E+10 | 1957.69 | 0.718724E+10 | 0.126700E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.311829E+10 | 0.775925E+09 | 591.86 | 0.256071E+10 | 0.557582E+09 | 0.00 | 0.66 | 0.00 | 3989.80 | 3208.83 | 1129.62 | 1099.94 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 21953972.77 | 5720011.61 | 9.50 | 20728803.49 | 1225169.28 | 0.00 | 0.20 | 23-APR-18:00 | 0.00 | 01-APR-00:10 | 1091.01 | 23-APR-18:00 | 1018.72 | 23-APR-18:00 | 72.28 | 23-APR-18:00 | 283.40 | 23-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.720251E+09 | 0.185489E+09 | 282.72 | 0.680834E+09 | 39417298.54 | 0.00 | 0.42 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 2267.29 | 25-MAY-18:00 | 2054.26 | 25-MAY-18:00 | 360.14 | 26-MAY-11:10 | 602.07 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.176656E+10 | 0.447905E+09 | 478.12 | 0.147645E+10 | 0.290105E+09 | 0.00 | 0.59 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 3312.01 | 29-JUN-16:02 | 2654.33 | 29-JUN-16:03 | 764.39 | 30-JUN-16:02 | 923.40 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.242517E+10 | 0.607333E+09 | 595.91 | 0.194720E+10 | 0.477970E+09 | 0.00 | 0.52 | 15-JUL-15:10 | 0.00 | 01-JUL-02:40 | 2992.11 | 15-JUL-15:10 | 2240.03 | 23-JUL-16:05 | 919.65 | 15-JUL-14:30 | 780.28 | 15-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.144908E+10 | 0.362434E+09 | 465.46 | 0.117957E+10 | 0.269500E+09 | 0.00 | 0.49 | 08-AUG-16:02 | 0.00 | 01-AUG-05:05 | 2761.35 | 08-AUG-16:02 | 2153.92 | 08-AUG-16:02 | 607.43 | 08-AUG-16:02 | 724.69 | 08-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.155841E+09 | 39460002.70 | 101.94 | 0.133532E+09 | 22309050.54 | 0.00 | 0.32 | 01-SEP-16:04 | 0.00 | 01-SEP-05:03 | 1742.99 | 01-SEP-16:04 | 1580.23 | 01-SEP-16:04 | 296.77 | 01-SEP-11:20 | 444.38 | 01-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.653885E+10 | 0.164834E+10 | 1933.65 | 0.543832E+10 | 0.110053E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.242517E+10 | 0.607333E+09 | 595.91 | 0.194720E+10 | 0.477970E+09 | 0.00 | 0.59 | 0.00 | 3312.01 | 2654.33 | 919.65 | 923.40 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 21473109.02 | 5596867.44 | 9.50 | 20266942.08 | 1206166.94 | 0.00 | 0.20 | 23-APR-18:00 | 0.00 | 01-APR-00:10 | 1059.49 | 23-APR-18:00 | 988.79 | 23-APR-18:00 | 70.69 | 23-APR-18:00 | 275.37 | 23-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.720497E+09 | 0.185512E+09 | 280.02 | 0.681127E+09 | 39369555.07 | 0.00 | 0.41 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 | 2229.96 | 25-MAY-18:00 | 2018.66 | 25-MAY-18:00 | 361.19 | 26-MAY-11:10 | 592.43 | 25-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.177455E+10 | 0.449820E+09 | 481.82 | 0.148418E+10 | 0.290376E+09 | 0.00 | 0.60 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 | 3291.15 | 29-JUN-16:02 | 2636.27 | 29-JUN-16:03 | 761.22 | 30-JUN-16:02 | 917.44 | 29-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.242877E+10 | 0.608063E+09 | 596.04 | 0.195055E+10 | 0.478215E+09 | 0.00 | 0.52 | 15-JUL-15:10 | 0.00 | 01-JUL-02:30 | 2981.73 | 15-JUL-15:10 | 2227.66 | 23-JUL-16:05 | 917.63 | 15-JUL-14:30 | 777.32 | 15-JUL-14:40 | 0.00 | 01-JUL-00:10 |
| August | 0.145045E+10 | 0.362715E+09 | 467.41 | 0.118103E+10 | 0.269416E+09 | 0.00 | 0.49 | 08-AUG-16:02 | 0.00 | 01-AUG-05:05 | 2745.39 | 08-AUG-16:02 | 2140.95 | 08-AUG-16:02 | 604.44 | 08-AUG-16:02 | 720.39 | 08-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.156671E+09 | 39673916.89 | 102.75 | 0.134422E+09 | 22249676.69 | 0.00 | 0.32 | 01-SEP-16:04 | 0.00 | 01-SEP-05:03 | 1726.35 | 01-SEP-16:04 | 1565.31 | 01-SEP-16:04 | 302.42 | 01-SEP-11:20 | 440.18 | 01-SEP-16:04 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.655241E+10 | 0.165138E+10 | 1937.54 | 0.545158E+10 | 0.110083E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.242877E+10 | 0.608063E+09 | 596.04 | 0.195055E+10 | 0.478215E+09 | 0.00 | 0.60 | 0.00 | 3291.15 | 2636.27 | 917.63 | 917.44 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 2710230.74 | 725780.97 | 4.50 | 2710230.74 | -0.0 | 0.00 | 0.07 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 351.59 | 28-FEB-15:10 | 351.59 | 28-FEB-15:10 | 0.00 | 28-FEB-15:40 | 93.80 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 20900698.02 | 5545070.06 | 19.33 | 20900698.02 | -0.0 | 0.00 | 0.14 | 26-MAR-15:20 | 0.00 | 01-MAR-00:10 | 719.03 | 26-MAR-15:20 | 719.03 | 26-MAR-15:20 | 0.00 | 19-MAR-15:20 | 188.96 | 26-MAR-15:20 | 0.00 | 01-MAR-00:10 |
| April | 0.251241E+09 | 65537134.28 | 103.50 | 0.248730E+09 | 2511373.20 | 0.00 | 0.41 | 23-APR-15:30 | 0.00 | 01-APR-00:10 | 2329.56 | 23-APR-15:30 | 2240.20 | 23-APR-15:20 | 113.99 | 23-APR-14:00 | 594.81 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.114329E+10 | 0.293449E+09 | 357.25 | 0.110205E+10 | 41233526.79 | 0.00 | 0.53 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 | 3012.29 | 18-MAY-13:40 | 3004.39 | 18-MAY-13:40 | 408.68 | 26-MAY-11:00 | 781.54 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.209152E+10 | 0.528733E+09 | 478.23 | 0.179412E+10 | 0.297393E+09 | 0.00 | 0.66 | 30-JUN-14:30 | 0.00 | 01-JUN-00:10 | 3984.22 | 30-JUN-13:40 | 3250.21 | 30-JUN-14:20 | 783.44 | 24-JUN-10:50 | 1044.50 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.295836E+10 | 0.737559E+09 | 592.05 | 0.244429E+10 | 0.514066E+09 | 0.00 | 0.65 | 23-JUL-13:30 | 0.00 | 01-JUL-02:40 | 3890.32 | 23-JUL-13:30 | 3271.01 | 23-JUL-13:30 | 1006.15 | 15-JUL-14:20 | 996.76 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.217658E+10 | 0.539470E+09 | 499.51 | 0.184841E+10 | 0.328175E+09 | 0.00 | 0.61 | 08-AUG-14:10 | 0.00 | 01-AUG-05:05 | 3635.54 | 08-AUG-14:10 | 3015.77 | 08-AUG-14:10 | 834.94 | 31-AUG-13:10 | 938.11 | 08-AUG-14:20 | 0.00 | 01-AUG-00:10 |
| September | 0.762277E+09 | 0.193156E+09 | 243.14 | 0.721163E+09 | 41114273.52 | 0.00 | 0.57 | 01-SEP-13:30 | 0.00 | 01-SEP-05:03 | 3432.88 | 01-SEP-13:30 | 3152.66 | 01-SEP-13:40 | 505.07 | 01-SEP-11:00 | 832.15 | 01-SEP-13:40 | 0.00 | 01-SEP-00:10 |
| October | 0.244998E+09 | 62846351.19 | 79.87 | 0.244485E+09 | 513449.97 | 0.00 | 0.38 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 | 2201.90 | 22-OCT-13:40 | 2178.22 | 22-OCT-13:50 | 42.86 | 22-OCT-12:40 | 545.60 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 |
| November | 2077273.24 | 556091.53 | 3.00 | 2077273.24 | 0.00 | 0.00 | 0.06 | 17-NOV-13:40 | 0.00 | 01-NOV-00:10 | 315.86 | 17-NOV-13:40 | 315.86 | 17-NOV-13:40 | 0.00 | 17-NOV-13:20 | 84.34 | 17-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.965394E+10 | 0.242758E+10 | 2380.39 | 0.842894E+10 | 0.122501E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.295836E+10 | 0.737559E+09 | 592.05 | 0.244429E+10 | 0.514066E+09 | 0.00 | 0.66 | 0.00 | 3984.22 | 3271.01 | 1006.15 | 1044.50 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 2881550.21 | 771469.91 | 4.50 | 2881550.21 | -0.0 | 0.00 | 0.07 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 362.19 | 28-FEB-15:10 | 362.19 | 28-FEB-15:10 | 0.00 | 28-FEB-14:10 | 96.59 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 21906646.32 | 5813542.41 | 19.88 | 21906646.32 | 0.00 | 0.00 | 0.14 | 26-MAR-15:20 | 0.00 | 01-MAR-00:10 | 725.65 | 26-MAR-15:20 | 725.65 | 26-MAR-15:20 | 0.00 | 26-MAR-16:08 | 190.64 | 26-MAR-15:20 | 0.00 | 01-MAR-00:10 |
| April | 0.255838E+09 | 66728956.52 | 105.32 | 0.253343E+09 | 2495003.37 | 0.00 | 0.41 | 23-APR-15:20 | 0.00 | 01-APR-00:10 | 2315.32 | 23-APR-15:20 | 2227.07 | 23-APR-15:20 | 114.02 | 23-APR-14:00 | 589.26 | 23-APR-15:30 | 0.00 | 01-APR-00:10 |
| May | 0.114587E+10 | 0.294023E+09 | 357.33 | 0.110468E+10 | 41192236.71 | 0.00 | 0.53 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 | 3023.80 | 18-MAY-13:40 | 3015.99 | 18-MAY-13:40 | 409.80 | 26-MAY-11:00 | 783.84 | 18-MAY-13:40 | 0.00 | 01-MAY-00:10 |
| June | 0.210036E+10 | 0.530759E+09 | 480.47 | 0.180273E+10 | 0.297639E+09 | 0.00 | 0.66 | 30-JUN-13:40 | 0.00 | 01-JUN-00:10 | 3989.60 | 30-JUN-13:40 | 3249.89 | 30-JUN-14:20 | 786.34 | 24-JUN-10:50 | 1041.19 | 30-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.296240E+10 | 0.738264E+09 | 592.87 | 0.244817E+10 | 0.514225E+09 | 0.00 | 0.65 | 23-JUL-13:30 | 0.00 | 01-JUL-02:40 | 3902.53 | 23-JUL-13:30 | 3283.99 | 23-JUL-13:30 | 1004.55 | 15-JUL-14:20 | 998.95 | 23-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.217788E+10 | 0.539582E+09 | 499.53 | 0.184987E+10 | 0.328004E+09 | 0.00 | 0.61 | 08-AUG-14:10 | 0.00 | 01-AUG-05:05 | 3642.49 | 08-AUG-14:10 | 3023.61 | 08-AUG-14:10 | 834.42 | 31-AUG-13:10 | 938.70 | 08-AUG-14:20 | 0.00 | 01-AUG-00:10 |
| September | 0.766395E+09 | 0.194143E+09 | 243.89 | 0.725381E+09 | 41014203.56 | 0.00 | 0.58 | 01-SEP-13:30 | 0.00 | 01-SEP-05:03 | 3447.13 | 01-SEP-13:30 | 3165.72 | 01-SEP-13:40 | 507.57 | 01-SEP-11:00 | 834.43 | 01-SEP-13:40 | 0.00 | 01-SEP-00:10 |
| October | 0.247239E+09 | 63398382.87 | 79.92 | 0.246715E+09 | 524074.52 | 0.00 | 0.39 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 | 2214.91 | 22-OCT-13:40 | 2189.26 | 22-OCT-13:50 | 43.07 | 22-OCT-12:40 | 548.41 | 22-OCT-13:40 | 0.00 | 01-OCT-00:10 |
| November | 2243920.47 | 600382.65 | 3.17 | 2243920.47 | -0.0 | 0.00 | 0.07 | 17-NOV-13:40 | 0.00 | 01-NOV-00:10 | 337.42 | 17-NOV-13:40 | 337.42 | 17-NOV-13:40 | 0.00 | 17-NOV-13:40 | 90.03 | 17-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.968302E+10 | 0.243408E+10 | 2386.87 | 0.845792E+10 | 0.122509E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.296240E+10 | 0.738264E+09 | 592.87 | 0.244817E+10 | 0.514225E+09 | 0.00 | 0.66 | 0.00 | 3989.60 | 3283.99 | 1004.55 | 1041.19 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 250.33 | 274.85 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 356.34 | 228.35 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 319.46 | 184.16 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 321.84 | 117.54 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 294.14 | 65.54 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 276.07 | 45.84 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 314.58 | 43.44 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 317.64 | 52.07 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 316.09 | 83.40 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 248.89 | 120.07 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 193.71 | 174.01 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 179.13 | 266.29 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 281.80 | 137.58 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 179.13 | 43.44 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 356.34 | 274.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 61.59 | 25.97 | 35.62 | 27.40 | 208.43 | 0.00 | 0.00 | 0.00 |
| February | 99.58 | 45.51 | 54.07 | 68.21 | 165.64 | 0.00 | 0.00 | 0.00 |
| March | 131.02 | 67.16 | 63.86 | 109.17 | 127.34 | 0.00 | 0.00 | 0.00 |
| April | 166.96 | 84.55 | 82.41 | 167.76 | 76.50 | 0.00 | 0.00 | 0.00 |
| May | 205.59 | 98.23 | 107.37 | 238.39 | 41.84 | 0.00 | 0.00 | 0.00 |
| June | 198.08 | 85.69 | 112.39 | 240.50 | 29.28 | 0.00 | 0.00 | 0.00 |
| July | 211.86 | 98.74 | 113.12 | 263.35 | 27.98 | 0.00 | 0.00 | 0.00 |
| August | 173.51 | 78.57 | 94.94 | 208.57 | 33.74 | 0.00 | 0.00 | 0.00 |
| September | 135.91 | 60.95 | 74.96 | 145.98 | 54.57 | 0.00 | 0.00 | 0.00 |
| October | 86.00 | 34.55 | 51.45 | 73.93 | 81.63 | 0.00 | 0.00 | 0.00 |
| November | 52.47 | 17.88 | 34.59 | 28.76 | 124.49 | 0.00 | 0.00 | 0.00 |
| December | 46.34 | 16.12 | 30.22 | 15.21 | 201.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.91 | 59.58 | 71.34 | 132.65 | 97.51 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.34 | 16.12 | 30.22 | 15.21 | 27.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 211.86 | 98.74 | 113.12 | 263.35 | 208.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 61.59 | 25.97 | 35.62 | 28.04 | 206.36 | 0.00 | 0.00 | 0.00 |
| February | 99.58 | 45.51 | 54.07 | 69.53 | 163.48 | 0.00 | 0.00 | 0.00 |
| March | 131.02 | 67.16 | 63.86 | 110.60 | 125.55 | 0.00 | 0.00 | 0.00 |
| April | 166.96 | 84.55 | 82.41 | 170.37 | 74.63 | 0.00 | 0.00 | 0.00 |
| May | 205.59 | 98.23 | 107.37 | 240.70 | 40.42 | 0.00 | 0.00 | 0.00 |
| June | 198.08 | 85.69 | 112.39 | 241.38 | 28.84 | 0.00 | 0.00 | 0.00 |
| July | 211.86 | 98.74 | 113.12 | 264.16 | 27.63 | 0.00 | 0.00 | 0.00 |
| August | 173.51 | 78.57 | 94.94 | 209.78 | 33.05 | 0.00 | 0.00 | 0.00 |
| September | 135.91 | 60.95 | 74.96 | 148.52 | 52.00 | 0.00 | 0.00 | 0.00 |
| October | 86.00 | 34.55 | 51.45 | 76.46 | 77.89 | 0.00 | 0.00 | 0.00 |
| November | 52.47 | 17.88 | 34.59 | 29.54 | 122.89 | 0.00 | 0.00 | 0.00 |
| December | 46.34 | 16.12 | 30.22 | 15.61 | 200.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.91 | 59.58 | 71.34 | 134.10 | 95.81 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.34 | 16.12 | 30.22 | 15.61 | 27.63 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 211.86 | 98.74 | 113.12 | 264.16 | 206.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.50 | 341.86 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 6.70 | 266.74 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 18.37 | 201.56 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 62.17 | 114.48 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 144.48 | 58.00 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 185.55 | 41.65 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 181.52 | 40.01 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 125.36 | 49.09 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 75.12 | 80.31 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.80 | 122.03 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.88 | 197.43 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.02 | 327.90 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 69.92 | 152.98 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.02 | 40.01 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 185.55 | 341.86 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 258.84 | 245.65 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 365.67 | 203.13 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 327.16 | 162.39 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 325.93 | 108.30 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 291.74 | 68.56 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 270.02 | 52.78 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 305.51 | 53.82 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 311.54 | 62.92 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 312.48 | 90.95 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 250.21 | 118.05 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 200.08 | 154.33 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 186.44 | 237.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 283.20 | 129.55 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 186.44 | 52.78 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 365.67 | 245.65 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.64 | 25.43 | 35.22 | 27.35 | 182.36 | 0.00 | 0.00 | 0.00 |
| February | 95.07 | 40.73 | 54.33 | 63.57 | 141.88 | 0.00 | 0.00 | 0.00 |
| March | 129.32 | 64.78 | 64.54 | 107.89 | 108.11 | 0.00 | 0.00 | 0.00 |
| April | 178.85 | 96.42 | 82.43 | 184.24 | 67.64 | 0.00 | 0.00 | 0.00 |
| May | 194.07 | 85.45 | 108.62 | 219.40 | 41.87 | 0.00 | 0.00 | 0.00 |
| June | 219.46 | 105.04 | 114.42 | 263.30 | 32.72 | 0.00 | 0.00 | 0.00 |
| July | 215.48 | 101.47 | 114.01 | 260.50 | 33.34 | 0.00 | 0.00 | 0.00 |
| August | 165.51 | 72.22 | 93.30 | 192.52 | 39.69 | 0.00 | 0.00 | 0.00 |
| September | 132.94 | 59.59 | 73.35 | 138.71 | 57.87 | 0.00 | 0.00 | 0.00 |
| October | 80.06 | 30.14 | 49.91 | 65.65 | 78.45 | 0.00 | 0.00 | 0.00 |
| November | 51.21 | 17.06 | 34.16 | 28.80 | 107.41 | 0.00 | 0.00 | 0.00 |
| December | 47.01 | 17.56 | 29.46 | 17.20 | 176.35 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.93 | 59.70 | 71.23 | 131.06 | 88.79 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.01 | 17.06 | 29.46 | 17.20 | 32.72 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 219.46 | 105.04 | 114.42 | 263.30 | 182.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.64 | 25.43 | 35.22 | 25.15 | 202.30 | 0.00 | 0.00 | 0.00 |
| February | 95.07 | 40.73 | 54.33 | 60.01 | 157.53 | 0.00 | 0.00 | 0.00 |
| March | 129.32 | 64.78 | 64.54 | 104.43 | 120.89 | 0.00 | 0.00 | 0.00 |
| April | 178.85 | 96.42 | 82.43 | 183.30 | 71.19 | 0.00 | 0.00 | 0.00 |
| May | 194.07 | 85.45 | 108.62 | 223.32 | 38.04 | 0.00 | 0.00 | 0.00 |
| June | 219.46 | 105.04 | 114.42 | 267.75 | 28.09 | 0.00 | 0.00 | 0.00 |
| July | 215.48 | 101.47 | 114.01 | 267.56 | 26.45 | 0.00 | 0.00 | 0.00 |
| August | 165.51 | 72.22 | 93.30 | 197.86 | 32.05 | 0.00 | 0.00 | 0.00 |
| September | 132.94 | 59.59 | 73.35 | 143.46 | 50.35 | 0.00 | 0.00 | 0.00 |
| October | 80.06 | 30.14 | 49.91 | 67.10 | 75.69 | 0.00 | 0.00 | 0.00 |
| November | 51.21 | 17.06 | 34.16 | 26.70 | 120.11 | 0.00 | 0.00 | 0.00 |
| December | 47.01 | 17.56 | 29.46 | 15.57 | 196.64 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.93 | 59.70 | 71.23 | 132.18 | 93.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.01 | 17.06 | 29.46 | 15.57 | 26.45 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 219.46 | 105.04 | 114.42 | 267.75 | 202.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.49 | 341.89 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 6.66 | 266.66 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 18.23 | 201.42 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 61.84 | 114.27 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 144.43 | 57.39 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 184.33 | 41.72 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 181.22 | 39.68 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 125.11 | 48.84 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 74.66 | 80.07 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.73 | 121.68 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.86 | 197.44 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.02 | 327.95 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 69.68 | 152.81 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.02 | 39.68 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 184.33 | 341.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.44 | 346.25 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 6.40 | 270.30 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 17.86 | 204.46 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 61.73 | 115.98 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 144.42 | 58.55 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 184.95 | 42.49 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 182.46 | 39.75 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 125.90 | 49.11 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 74.55 | 81.86 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.39 | 123.58 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.67 | 200.23 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.01 | 332.12 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 69.78 | 154.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.01 | 39.75 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 184.95 | 346.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.44 | 346.25 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 6.39 | 270.30 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 17.86 | 204.45 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 61.71 | 115.97 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 144.44 | 58.51 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 184.84 | 42.53 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 182.45 | 39.74 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 125.89 | 49.11 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 74.52 | 81.86 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.39 | 123.55 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.67 | 200.23 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.01 | 332.12 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 69.77 | 154.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.01 | 39.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 184.84 | 346.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 248.97 | 278.47 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 354.94 | 231.50 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 318.29 | 186.99 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 320.77 | 119.47 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 293.60 | 66.50 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 275.57 | 46.85 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 315.40 | 43.20 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 318.10 | 52.09 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 315.39 | 85.03 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 247.74 | 122.72 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 192.78 | 176.67 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 178.06 | 269.84 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 281.09 | 139.55 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 178.06 | 43.20 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 354.94 | 278.47 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 249.33 | 277.43 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 355.39 | 230.52 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 318.68 | 186.09 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 321.01 | 119.00 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 293.35 | 66.66 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 275.05 | 47.25 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 314.94 | 43.59 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 317.72 | 52.50 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 315.06 | 85.47 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 247.72 | 122.70 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 193.11 | 175.74 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 178.36 | 268.80 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 281.10 | 139.26 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 178.36 | 43.59 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 355.39 | 277.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 246.77 | 282.16 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 351.42 | 235.67 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 314.00 | 192.94 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 313.81 | 128.09 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 285.86 | 73.68 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 270.97 | 49.72 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 312.71 | 44.29 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 316.15 | 52.76 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 314.10 | 85.15 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 246.37 | 123.48 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 191.31 | 178.62 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 176.50 | 273.12 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.79 | 142.91 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 176.50 | 44.29 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 351.42 | 282.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 61.59 | 25.97 | 35.62 | 26.43 | 214.69 | 0.00 | 0.00 | 0.00 |
| February | 99.58 | 45.51 | 54.07 | 66.11 | 171.59 | 0.00 | 0.00 | 0.00 |
| March | 131.02 | 67.16 | 63.86 | 106.12 | 133.72 | 0.00 | 0.00 | 0.00 |
| April | 166.96 | 84.55 | 82.41 | 162.10 | 83.22 | 0.00 | 0.00 | 0.00 |
| May | 205.59 | 98.23 | 107.37 | 232.56 | 46.79 | 0.00 | 0.00 | 0.00 |
| June | 198.08 | 85.69 | 112.39 | 236.94 | 31.68 | 0.00 | 0.00 | 0.00 |
| July | 211.86 | 98.74 | 113.12 | 262.00 | 28.52 | 0.00 | 0.00 | 0.00 |
| August | 173.51 | 78.57 | 94.94 | 207.60 | 34.21 | 0.00 | 0.00 | 0.00 |
| September | 135.91 | 60.95 | 74.96 | 144.74 | 55.77 | 0.00 | 0.00 | 0.00 |
| October | 86.00 | 34.55 | 51.45 | 72.46 | 84.08 | 0.00 | 0.00 | 0.00 |
| November | 52.47 | 17.88 | 34.59 | 27.82 | 128.19 | 0.00 | 0.00 | 0.00 |
| December | 46.34 | 16.12 | 30.22 | 14.62 | 207.66 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.91 | 59.58 | 71.34 | 130.34 | 101.40 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.34 | 16.12 | 30.22 | 14.62 | 28.52 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 211.86 | 98.74 | 113.12 | 262.00 | 214.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 61.59 | 25.97 | 35.62 | 27.13 | 212.69 | 0.00 | 0.00 | 0.00 |
| February | 99.58 | 45.51 | 54.07 | 67.73 | 169.22 | 0.00 | 0.00 | 0.00 |
| March | 131.02 | 67.16 | 63.86 | 108.14 | 131.41 | 0.00 | 0.00 | 0.00 |
| April | 166.96 | 84.55 | 82.41 | 165.44 | 80.52 | 0.00 | 0.00 | 0.00 |
| May | 205.59 | 98.23 | 107.37 | 233.97 | 46.04 | 0.00 | 0.00 | 0.00 |
| June | 198.08 | 85.69 | 112.39 | 237.44 | 31.57 | 0.00 | 0.00 | 0.00 |
| July | 211.86 | 98.74 | 113.12 | 262.68 | 28.33 | 0.00 | 0.00 | 0.00 |
| August | 173.51 | 78.57 | 94.94 | 208.61 | 33.80 | 0.00 | 0.00 | 0.00 |
| September | 135.91 | 60.95 | 74.96 | 146.76 | 54.15 | 0.00 | 0.00 | 0.00 |
| October | 86.00 | 34.55 | 51.45 | 74.89 | 80.73 | 0.00 | 0.00 | 0.00 |
| November | 52.47 | 17.88 | 34.59 | 28.70 | 126.60 | 0.00 | 0.00 | 0.00 |
| December | 46.34 | 16.12 | 30.22 | 15.07 | 206.09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.91 | 59.58 | 71.34 | 131.76 | 99.82 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.34 | 16.12 | 30.22 | 15.07 | 28.33 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 211.86 | 98.74 | 113.12 | 262.68 | 212.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.36 | 352.09 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.73 | 276.54 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 16.17 | 211.65 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 55.83 | 124.12 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 133.87 | 66.04 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 179.33 | 45.40 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 179.58 | 40.95 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 123.93 | 50.14 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 72.99 | 83.65 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 28.03 | 126.59 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.38 | 203.38 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.00 | 337.11 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 67.06 | 159.35 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.00 | 40.95 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 179.58 | 352.09 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 246.62 | 282.06 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 351.24 | 235.38 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 313.60 | 192.45 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 312.75 | 127.78 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 285.40 | 73.23 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 270.38 | 49.52 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 312.34 | 43.96 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 315.92 | 52.47 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 313.80 | 84.80 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 246.22 | 123.08 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 191.19 | 178.53 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 176.38 | 273.07 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.45 | 142.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 176.38 | 43.96 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 351.24 | 282.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.64 | 25.43 | 35.22 | 23.91 | 210.64 | 0.00 | 0.00 | 0.00 |
| February | 95.07 | 40.73 | 54.33 | 57.21 | 165.84 | 0.00 | 0.00 | 0.00 |
| March | 129.32 | 64.78 | 64.54 | 100.24 | 129.22 | 0.00 | 0.00 | 0.00 |
| April | 178.85 | 96.42 | 82.43 | 174.79 | 79.77 | 0.00 | 0.00 | 0.00 |
| May | 194.07 | 85.45 | 108.62 | 214.54 | 44.42 | 0.00 | 0.00 | 0.00 |
| June | 219.46 | 105.04 | 114.42 | 263.49 | 30.64 | 0.00 | 0.00 | 0.00 |
| July | 215.48 | 101.47 | 114.01 | 265.44 | 27.34 | 0.00 | 0.00 | 0.00 |
| August | 165.51 | 72.22 | 93.30 | 195.72 | 33.17 | 0.00 | 0.00 | 0.00 |
| September | 132.94 | 59.59 | 73.35 | 139.75 | 53.95 | 0.00 | 0.00 | 0.00 |
| October | 80.06 | 30.14 | 49.91 | 63.19 | 81.86 | 0.00 | 0.00 | 0.00 |
| November | 51.21 | 17.06 | 34.16 | 25.31 | 125.47 | 0.00 | 0.00 | 0.00 |
| December | 47.01 | 17.56 | 29.46 | 14.84 | 204.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.93 | 59.70 | 71.23 | 128.54 | 98.60 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.01 | 17.06 | 29.46 | 14.84 | 27.34 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 219.46 | 105.04 | 114.42 | 265.44 | 210.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.64 | 25.43 | 35.22 | 24.30 | 208.38 | 0.00 | 0.00 | 0.00 |
| February | 95.07 | 40.73 | 54.33 | 58.31 | 163.07 | 0.00 | 0.00 | 0.00 |
| March | 129.32 | 64.78 | 64.54 | 101.94 | 126.59 | 0.00 | 0.00 | 0.00 |
| April | 178.85 | 96.42 | 82.43 | 178.16 | 76.86 | 0.00 | 0.00 | 0.00 |
| May | 194.07 | 85.45 | 108.62 | 215.92 | 43.66 | 0.00 | 0.00 | 0.00 |
| June | 219.46 | 105.04 | 114.42 | 264.00 | 30.52 | 0.00 | 0.00 | 0.00 |
| July | 215.48 | 101.47 | 114.01 | 266.12 | 27.13 | 0.00 | 0.00 | 0.00 |
| August | 165.51 | 72.22 | 93.30 | 196.72 | 32.75 | 0.00 | 0.00 | 0.00 |
| September | 132.94 | 59.59 | 73.35 | 141.68 | 52.37 | 0.00 | 0.00 | 0.00 |
| October | 80.06 | 30.14 | 49.91 | 65.56 | 78.42 | 0.00 | 0.00 | 0.00 |
| November | 51.21 | 17.06 | 34.16 | 25.91 | 123.65 | 0.00 | 0.00 | 0.00 |
| December | 47.01 | 17.56 | 29.46 | 15.06 | 202.23 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.93 | 59.70 | 71.23 | 129.81 | 96.88 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.01 | 17.06 | 29.46 | 15.06 | 27.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 219.46 | 105.04 | 114.42 | 266.12 | 208.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.36 | 352.12 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.68 | 276.45 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 16.00 | 211.37 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 55.07 | 123.69 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 133.33 | 65.62 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 178.70 | 45.18 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 179.21 | 40.65 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 123.68 | 49.86 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 72.46 | 83.31 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 27.89 | 126.13 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.35 | 203.39 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.00 | 337.16 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 66.77 | 159.12 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.00 | 40.65 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 179.21 | 352.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.33 | 355.90 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.54 | 279.41 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 15.95 | 213.49 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 56.14 | 124.58 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 134.57 | 66.15 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 180.36 | 45.28 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 181.01 | 40.50 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 124.78 | 49.99 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 72.43 | 85.34 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 27.51 | 128.58 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.18 | 206.29 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.00 | 340.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 67.28 | 160.91 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.00 | 40.50 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 181.01 | 355.90 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.33 | 355.90 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.54 | 279.41 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 15.94 | 213.48 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 56.09 | 124.56 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 134.53 | 66.14 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 180.34 | 45.27 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 181.00 | 40.49 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 124.77 | 49.98 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 72.40 | 85.33 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 27.51 | 128.54 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.18 | 206.29 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.00 | 340.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 67.27 | 160.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.00 | 40.49 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 181.00 | 355.90 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 245.55 | 285.63 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 350.21 | 238.51 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 313.21 | 195.08 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 313.06 | 129.72 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 286.24 | 73.94 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 271.93 | 49.57 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 314.00 | 43.78 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 316.90 | 52.60 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 313.59 | 86.68 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 245.19 | 126.37 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 190.29 | 181.38 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 175.51 | 276.67 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.44 | 144.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 175.51 | 43.78 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 350.21 | 285.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 245.55 | 285.63 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 350.21 | 238.50 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 313.19 | 195.06 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 313.00 | 129.73 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 286.21 | 73.92 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 271.91 | 49.56 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 313.98 | 43.77 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 316.89 | 52.59 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 313.59 | 86.66 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 245.19 | 126.33 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 190.28 | 181.38 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 175.50 | 276.67 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.43 | 144.58 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 175.50 | 43.77 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 350.21 | 285.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 247.71 | 275.60 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 351.49 | 229.75 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 313.77 | 187.48 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 314.23 | 122.03 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 287.03 | 68.31 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 270.90 | 46.26 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 311.24 | 42.26 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 315.61 | 49.63 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 316.46 | 77.15 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 247.91 | 116.14 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 191.83 | 173.13 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 177.37 | 266.64 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 278.26 | 137.47 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 177.37 | 42.26 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 351.49 | 275.60 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 61.59 | 25.97 | 35.62 | 26.44 | 209.69 | 0.00 | 0.00 | 0.00 |
| February | 99.58 | 45.51 | 54.07 | 65.72 | 167.15 | 0.00 | 0.00 | 0.00 |
| March | 131.02 | 67.16 | 63.86 | 105.55 | 129.66 | 0.00 | 0.00 | 0.00 |
| April | 166.96 | 84.55 | 82.41 | 162.06 | 78.90 | 0.00 | 0.00 | 0.00 |
| May | 205.59 | 98.23 | 107.37 | 233.33 | 43.17 | 0.00 | 0.00 | 0.00 |
| June | 198.08 | 85.69 | 112.39 | 236.86 | 29.34 | 0.00 | 0.00 | 0.00 |
| July | 211.86 | 98.74 | 113.12 | 260.97 | 27.11 | 0.00 | 0.00 | 0.00 |
| August | 173.51 | 78.57 | 94.94 | 207.25 | 32.07 | 0.00 | 0.00 | 0.00 |
| September | 135.91 | 60.95 | 74.96 | 146.11 | 50.25 | 0.00 | 0.00 | 0.00 |
| October | 86.00 | 34.55 | 51.45 | 73.13 | 78.82 | 0.00 | 0.00 | 0.00 |
| November | 52.47 | 17.88 | 34.59 | 27.83 | 124.15 | 0.00 | 0.00 | 0.00 |
| December | 46.34 | 16.12 | 30.22 | 14.63 | 202.80 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.91 | 59.58 | 71.34 | 130.37 | 97.49 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.34 | 16.12 | 30.22 | 14.63 | 27.11 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 211.86 | 98.74 | 113.12 | 260.97 | 209.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 61.59 | 25.97 | 35.62 | 27.46 | 207.81 | 0.00 | 0.00 | 0.00 |
| February | 99.58 | 45.51 | 54.07 | 68.11 | 164.99 | 0.00 | 0.00 | 0.00 |
| March | 131.02 | 67.16 | 63.86 | 108.44 | 127.73 | 0.00 | 0.00 | 0.00 |
| April | 166.96 | 84.55 | 82.41 | 165.66 | 77.44 | 0.00 | 0.00 | 0.00 |
| May | 205.59 | 98.23 | 107.37 | 235.14 | 42.71 | 0.00 | 0.00 | 0.00 |
| June | 198.08 | 85.69 | 112.39 | 237.49 | 29.29 | 0.00 | 0.00 | 0.00 |
| July | 211.86 | 98.74 | 113.12 | 261.86 | 27.00 | 0.00 | 0.00 | 0.00 |
| August | 173.51 | 78.57 | 94.94 | 208.75 | 31.66 | 0.00 | 0.00 | 0.00 |
| September | 135.91 | 60.95 | 74.96 | 149.05 | 48.84 | 0.00 | 0.00 | 0.00 |
| October | 86.00 | 34.55 | 51.45 | 75.76 | 76.97 | 0.00 | 0.00 | 0.00 |
| November | 52.47 | 17.88 | 34.59 | 29.09 | 122.77 | 0.00 | 0.00 | 0.00 |
| December | 46.34 | 16.12 | 30.22 | 15.32 | 201.31 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.91 | 59.58 | 71.34 | 132.22 | 96.28 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.34 | 16.12 | 30.22 | 15.32 | 27.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 211.86 | 98.74 | 113.12 | 261.86 | 207.81 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.40 | 344.30 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 6.05 | 269.93 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 16.62 | 206.21 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 56.45 | 119.72 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 136.25 | 61.60 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 180.04 | 42.52 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 178.83 | 39.35 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 124.51 | 47.18 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 76.54 | 75.65 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.32 | 120.86 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.69 | 197.35 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.01 | 329.56 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 67.85 | 154.07 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.01 | 39.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 180.04 | 344.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 247.48 | 275.43 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 351.20 | 229.31 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 313.03 | 186.70 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 312.60 | 121.23 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 285.92 | 67.41 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 269.42 | 45.75 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 310.38 | 41.63 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 314.97 | 49.06 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 315.59 | 76.51 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 247.55 | 115.65 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 191.63 | 172.97 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 177.19 | 266.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.54 | 136.96 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 177.19 | 41.63 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 351.20 | 275.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.64 | 25.43 | 35.22 | 24.30 | 205.83 | 0.00 | 0.00 | 0.00 |
| February | 95.07 | 40.73 | 54.33 | 57.55 | 161.90 | 0.00 | 0.00 | 0.00 |
| March | 129.32 | 64.78 | 64.54 | 100.26 | 125.71 | 0.00 | 0.00 | 0.00 |
| April | 178.85 | 96.42 | 82.43 | 175.17 | 75.85 | 0.00 | 0.00 | 0.00 |
| May | 194.07 | 85.45 | 108.62 | 215.51 | 41.20 | 0.00 | 0.00 | 0.00 |
| June | 219.46 | 105.04 | 114.42 | 263.23 | 28.54 | 0.00 | 0.00 | 0.00 |
| July | 215.48 | 101.47 | 114.01 | 264.45 | 26.05 | 0.00 | 0.00 | 0.00 |
| August | 165.51 | 72.22 | 93.30 | 195.38 | 31.13 | 0.00 | 0.00 | 0.00 |
| September | 132.94 | 59.59 | 73.35 | 141.45 | 48.90 | 0.00 | 0.00 | 0.00 |
| October | 80.06 | 30.14 | 49.91 | 64.24 | 77.00 | 0.00 | 0.00 | 0.00 |
| November | 51.21 | 17.06 | 34.16 | 25.68 | 121.65 | 0.00 | 0.00 | 0.00 |
| December | 47.01 | 17.56 | 29.46 | 15.10 | 199.17 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.93 | 59.70 | 71.23 | 128.86 | 94.99 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.01 | 17.06 | 29.46 | 15.10 | 26.05 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 219.46 | 105.04 | 114.42 | 264.45 | 205.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.64 | 25.43 | 35.22 | 24.81 | 203.51 | 0.00 | 0.00 | 0.00 |
| February | 95.07 | 40.73 | 54.33 | 59.01 | 158.99 | 0.00 | 0.00 | 0.00 |
| March | 129.32 | 64.78 | 64.54 | 102.54 | 123.08 | 0.00 | 0.00 | 0.00 |
| April | 178.85 | 96.42 | 82.43 | 178.57 | 73.99 | 0.00 | 0.00 | 0.00 |
| May | 194.07 | 85.45 | 108.62 | 217.17 | 40.63 | 0.00 | 0.00 | 0.00 |
| June | 219.46 | 105.04 | 114.42 | 263.87 | 28.48 | 0.00 | 0.00 | 0.00 |
| July | 215.48 | 101.47 | 114.01 | 265.38 | 25.91 | 0.00 | 0.00 | 0.00 |
| August | 165.51 | 72.22 | 93.30 | 196.82 | 30.71 | 0.00 | 0.00 | 0.00 |
| September | 132.94 | 59.59 | 73.35 | 144.06 | 47.40 | 0.00 | 0.00 | 0.00 |
| October | 80.06 | 30.14 | 49.91 | 66.63 | 74.80 | 0.00 | 0.00 | 0.00 |
| November | 51.21 | 17.06 | 34.16 | 26.43 | 119.84 | 0.00 | 0.00 | 0.00 |
| December | 47.01 | 17.56 | 29.46 | 15.41 | 197.35 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 130.93 | 59.70 | 71.23 | 130.39 | 93.48 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.01 | 17.06 | 29.46 | 15.41 | 25.91 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 219.46 | 105.04 | 114.42 | 265.38 | 203.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.40 | 344.34 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.96 | 269.78 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 16.32 | 205.69 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 55.15 | 118.90 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 135.05 | 60.80 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 178.56 | 42.06 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 178.08 | 38.77 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 123.78 | 46.65 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 75.23 | 74.96 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 28.98 | 120.25 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.64 | 197.33 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.01 | 329.63 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 67.22 | 153.65 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.01 | 38.77 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 178.56 | 344.34 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.37 | 348.88 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.86 | 273.29 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 16.44 | 208.27 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 56.97 | 120.31 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 137.26 | 62.10 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 180.88 | 43.07 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 180.29 | 39.35 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 125.19 | 47.82 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 76.58 | 76.87 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.16 | 122.31 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.51 | 200.44 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.00 | 334.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 68.17 | 155.95 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.00 | 39.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 180.88 | 348.88 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.81 | 0.00 | 41.81 | 0.37 | 348.88 | 0.00 | 0.00 | 0.00 |
| February | 64.23 | 0.00 | 64.23 | 5.85 | 273.28 | 0.00 | 0.00 | 0.00 |
| March | 79.04 | 0.01 | 79.04 | 16.42 | 208.23 | 0.00 | 0.00 | 0.00 |
| April | 103.82 | 1.02 | 102.81 | 56.85 | 120.26 | 0.00 | 0.00 | 0.00 |
| May | 145.83 | 7.85 | 137.98 | 137.14 | 62.05 | 0.00 | 0.00 | 0.00 |
| June | 162.54 | 17.78 | 144.76 | 180.77 | 43.05 | 0.00 | 0.00 | 0.00 |
| July | 155.14 | 13.12 | 142.02 | 180.25 | 39.31 | 0.00 | 0.00 | 0.00 |
| August | 118.39 | 2.39 | 116.00 | 125.15 | 47.79 | 0.00 | 0.00 | 0.00 |
| September | 92.02 | 0.07 | 91.96 | 76.45 | 76.83 | 0.00 | 0.00 | 0.00 |
| October | 63.83 | 0.00 | 63.83 | 29.12 | 122.26 | 0.00 | 0.00 | 0.00 |
| November | 42.26 | 0.00 | 42.26 | 4.50 | 200.43 | 0.00 | 0.00 | 0.00 |
| December | 35.43 | 0.00 | 35.43 | 0.00 | 334.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 92.17 | 3.54 | 88.63 | 68.12 | 155.92 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 35.43 | 0.00 | 35.43 | 0.00 | 39.31 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 162.54 | 17.78 | 144.76 | 180.77 | 348.88 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 246.38 | 279.36 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 350.24 | 232.87 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 312.98 | 189.81 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 313.79 | 123.47 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 287.53 | 68.96 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 271.70 | 46.85 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 312.56 | 42.28 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 316.17 | 50.30 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 316.04 | 78.97 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 247.25 | 118.38 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 190.83 | 176.04 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 176.25 | 270.50 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.95 | 139.42 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 176.25 | 42.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 350.24 | 279.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 288.25 | 200.38 | 87.87 | 246.37 | 279.35 | 0.00 | 0.00 | 0.00 |
| February | 363.78 | 245.44 | 118.34 | 350.22 | 232.83 | 0.00 | 0.00 | 0.00 |
| March | 317.18 | 199.25 | 117.93 | 312.93 | 189.76 | 0.00 | 0.00 | 0.00 |
| April | 291.36 | 158.27 | 133.09 | 313.67 | 123.42 | 0.00 | 0.00 | 0.00 |
| May | 246.57 | 85.54 | 161.03 | 287.45 | 68.89 | 0.00 | 0.00 | 0.00 |
| June | 220.06 | 59.02 | 161.04 | 271.60 | 46.82 | 0.00 | 0.00 | 0.00 |
| July | 242.90 | 78.88 | 164.02 | 312.52 | 42.23 | 0.00 | 0.00 | 0.00 |
| August | 253.50 | 104.37 | 149.14 | 316.13 | 50.26 | 0.00 | 0.00 | 0.00 |
| September | 271.20 | 142.83 | 128.37 | 315.99 | 78.92 | 0.00 | 0.00 | 0.00 |
| October | 237.46 | 140.86 | 96.60 | 247.23 | 118.34 | 0.00 | 0.00 | 0.00 |
| November | 208.15 | 130.25 | 77.90 | 190.81 | 176.03 | 0.00 | 0.00 | 0.00 |
| December | 222.65 | 146.06 | 76.58 | 176.24 | 270.50 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 262.94 | 140.27 | 122.67 | 277.90 | 139.38 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 208.15 | 59.02 | 76.58 | 176.24 | 42.23 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 363.78 | 245.44 | 164.02 | 350.22 | 279.35 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 14.55 | 6.10 | 8.45 | 5.90 | 49.30 | 6.67 | 0.00 | 0.00 |
| February | 22.81 | 9.77 | 13.04 | 13.93 | 39.03 | 0.17 | 0.00 | 0.00 |
| March | 31.03 | 15.54 | 15.49 | 24.21 | 30.76 | 53.00 | 0.00 | 0.00 |
| April | 42.92 | 23.14 | 19.78 | 42.09 | 19.17 | 52.83 | 0.00 | 0.00 |
| May | 46.57 | 20.50 | 26.06 | 51.04 | 11.08 | 226.50 | 0.00 | 0.00 |
| June | 52.66 | 25.21 | 27.45 | 62.12 | 7.96 | 265.00 | 0.00 | 0.00 |
| July | 51.71 | 24.35 | 27.36 | 62.40 | 7.31 | 315.00 | 0.00 | 0.00 |
| August | 39.72 | 17.33 | 22.39 | 46.09 | 8.70 | 350.50 | 0.00 | 0.00 |
| September | 31.90 | 14.30 | 17.60 | 33.64 | 13.03 | 323.83 | 0.00 | 0.00 |
| October | 19.21 | 7.23 | 11.98 | 15.37 | 19.52 | 274.67 | 0.00 | 0.00 |
| November | 12.29 | 4.09 | 8.20 | 6.11 | 29.85 | 14.17 | 0.00 | 0.00 |
| December | 11.28 | 4.21 | 7.07 | 3.66 | 47.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 31.42 | 14.33 | 17.09 | 30.62 | 23.57 | 1882.33 | 0.00 | 0.00 |
| Minimum of Months | 11.28 | 4.09 | 7.07 | 3.66 | 7.31 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 52.66 | 25.21 | 27.45 | 62.40 | 49.30 | 350.50 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.34 | 18.17 | 25.17 | 20.38 | 127.22 | 0.00 | 0.00 | 0.00 |
| February | 67.94 | 29.11 | 38.83 | 46.26 | 101.50 | 0.00 | 0.00 | 0.00 |
| March | 92.42 | 46.30 | 46.12 | 77.63 | 79.27 | 0.00 | 0.00 | 0.00 |
| April | 127.81 | 68.90 | 58.91 | 131.68 | 50.36 | 0.00 | 0.00 | 0.00 |
| May | 138.69 | 61.07 | 77.62 | 157.05 | 29.85 | 0.00 | 0.00 | 0.00 |
| June | 156.84 | 75.07 | 81.77 | 187.56 | 22.78 | 12.33 | 0.00 | 0.00 |
| July | 153.99 | 72.52 | 81.48 | 186.60 | 22.09 | 23.83 | 0.00 | 0.00 |
| August | 118.28 | 51.61 | 66.68 | 138.15 | 26.19 | 5.00 | 0.00 | 0.00 |
| September | 95.00 | 42.58 | 52.42 | 100.62 | 39.08 | 2.67 | 0.00 | 0.00 |
| October | 57.21 | 21.54 | 35.67 | 47.72 | 54.68 | 0.00 | 0.00 | 0.00 |
| November | 36.60 | 12.19 | 24.41 | 20.30 | 79.27 | 0.00 | 0.00 | 0.00 |
| December | 33.60 | 12.55 | 21.05 | 12.78 | 123.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 93.57 | 42.67 | 50.90 | 94.11 | 62.87 | 43.83 | 0.00 | 0.00 |
| Minimum of Months | 33.60 | 12.19 | 21.05 | 12.78 | 22.09 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 156.84 | 75.07 | 81.77 | 187.56 | 127.22 | 23.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 14.55 | 6.10 | 8.45 | 5.57 | 52.07 | 211.00 | 0.00 | 0.00 |
| February | 22.81 | 9.77 | 13.04 | 13.42 | 41.24 | 144.33 | 0.00 | 0.00 |
| March | 31.03 | 15.54 | 15.49 | 23.67 | 32.51 | 369.33 | 0.00 | 0.00 |
| April | 42.92 | 23.14 | 19.78 | 41.42 | 20.36 | 191.33 | 0.00 | 0.00 |
| May | 46.57 | 20.50 | 26.06 | 50.31 | 11.76 | 363.83 | 0.00 | 0.00 |
| June | 52.66 | 25.21 | 27.45 | 61.83 | 8.36 | 336.00 | 0.00 | 0.00 |
| July | 51.71 | 24.35 | 27.36 | 62.35 | 7.53 | 358.33 | 0.00 | 0.00 |
| August | 39.72 | 17.33 | 22.39 | 45.86 | 9.11 | 412.17 | 0.00 | 0.00 |
| September | 31.90 | 14.30 | 17.60 | 32.71 | 14.30 | 449.83 | 0.00 | 0.00 |
| October | 19.21 | 7.23 | 11.98 | 14.71 | 21.08 | 526.00 | 0.00 | 0.00 |
| November | 12.29 | 4.09 | 8.20 | 5.80 | 31.80 | 198.83 | 0.00 | 0.00 |
| December | 11.28 | 4.21 | 7.07 | 3.45 | 50.61 | 198.17 | 0.00 | 0.00 |
| Annual Sum or Average | 31.42 | 14.33 | 17.09 | 30.17 | 25.00 | 3759.17 | 0.00 | 0.00 |
| Minimum of Months | 11.28 | 4.09 | 7.07 | 3.45 | 7.53 | 144.33 | 0.00 | 0.00 |
| Maximum of Months | 52.66 | 25.21 | 27.45 | 62.35 | 52.07 | 526.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.670479E+09 | 0.736154E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.862051E+09 | 0.552430E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.855630E+09 | 0.493265E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.834212E+09 | 0.304674E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.787829E+09 | 0.175548E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.715572E+09 | 0.118820E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.842559E+09 | 0.116358E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.850756E+09 | 0.139460E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.819311E+09 | 0.216160E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.666628E+09 | 0.321607E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.502109E+09 | 0.451036E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.479784E+09 | 0.713219E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.888692E+10 | 0.433873E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.479784E+09 | 0.116358E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.862051E+09 | 0.736154E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.164958E+09 | 69549419.71 | 95408477.45 | 73394976.70 | 0.558262E+09 |
| February | 0.240892E+09 | 0.110089E+09 | 0.130803E+09 | 0.165015E+09 | 0.400709E+09 |
| March | 0.350925E+09 | 0.179876E+09 | 0.171048E+09 | 0.292409E+09 | 0.341065E+09 |
| April | 0.432766E+09 | 0.219151E+09 | 0.213615E+09 | 0.434828E+09 | 0.198297E+09 |
| May | 0.550658E+09 | 0.263092E+09 | 0.287566E+09 | 0.638507E+09 | 0.112059E+09 |
| June | 0.513421E+09 | 0.222117E+09 | 0.291304E+09 | 0.623379E+09 | 75896488.07 |
| July | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.705346E+09 | 74934956.56 |
| August | 0.464729E+09 | 0.210452E+09 | 0.254278E+09 | 0.558630E+09 | 90369006.48 |
| September | 0.352288E+09 | 0.157978E+09 | 0.194309E+09 | 0.378370E+09 | 0.141445E+09 |
| October | 0.230337E+09 | 92544862.74 | 0.137792E+09 | 0.198006E+09 | 0.218641E+09 |
| November | 0.135993E+09 | 46332842.64 | 89659854.57 | 74550870.52 | 0.322675E+09 |
| December | 0.124105E+09 | 43172232.58 | 80932824.48 | 40738092.69 | 0.540679E+09 |
| Annual Sum or Average | 0.412853E+10 | 0.187882E+10 | 0.224971E+10 | 0.418317E+10 | 0.307503E+10 |
| Minimum of Months | 0.124105E+09 | 43172232.58 | 80932824.48 | 40738092.69 | 74934956.56 |
| Maximum of Months | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.705346E+09 | 0.558262E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.164958E+09 | 69549419.71 | 95408477.45 | 75089906.43 | 0.552725E+09 |
| February | 0.240892E+09 | 0.110089E+09 | 0.130803E+09 | 0.168217E+09 | 0.395490E+09 |
| March | 0.350925E+09 | 0.179876E+09 | 0.171048E+09 | 0.296231E+09 | 0.336261E+09 |
| April | 0.432766E+09 | 0.219151E+09 | 0.213615E+09 | 0.441592E+09 | 0.193430E+09 |
| May | 0.550658E+09 | 0.263092E+09 | 0.287566E+09 | 0.644679E+09 | 0.108266E+09 |
| June | 0.513421E+09 | 0.222117E+09 | 0.291304E+09 | 0.625667E+09 | 74750186.09 |
| July | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.707518E+09 | 74011050.71 |
| August | 0.464729E+09 | 0.210452E+09 | 0.254278E+09 | 0.561868E+09 | 88518640.07 |
| September | 0.352288E+09 | 0.157978E+09 | 0.194309E+09 | 0.384955E+09 | 0.134789E+09 |
| October | 0.230337E+09 | 92544862.74 | 0.137792E+09 | 0.204789E+09 | 0.208612E+09 |
| November | 0.135993E+09 | 46332842.64 | 89659854.57 | 76562578.95 | 0.318518E+09 |
| December | 0.124105E+09 | 43172232.58 | 80932824.48 | 41822542.49 | 0.536191E+09 |
| Annual Sum or Average | 0.412853E+10 | 0.187882E+10 | 0.224971E+10 | 0.422899E+10 | 0.302156E+10 |
| Minimum of Months | 0.124105E+09 | 43172232.58 | 80932824.48 | 41822542.49 | 74011050.71 |
| Maximum of Months | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.707518E+09 | 0.552725E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 1328984.94 | 0.915627E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 16217141.61 | 0.645307E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 49196798.43 | 0.539866E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.161144E+09 | 0.296740E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.386972E+09 | 0.155337E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.480939E+09 | 0.107960E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.486172E+09 | 0.107151E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.335767E+09 | 0.131488E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.194720E+09 | 0.208165E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 79828379.25 | 0.326837E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 12658372.16 | 0.511751E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 41409.17 | 0.878257E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.220499E+10 | 0.482449E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 41409.17 | 0.107151E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.486172E+09 | 0.915627E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.693275E+09 | 0.657950E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.884625E+09 | 0.491411E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.876269E+09 | 0.434935E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.844814E+09 | 0.280723E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.781385E+09 | 0.183643E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.699886E+09 | 0.136798E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.818290E+09 | 0.144144E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.834417E+09 | 0.168516E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.809950E+09 | 0.235743E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.670166E+09 | 0.316177E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.518613E+09 | 0.400036E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.499349E+09 | 0.635450E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.893104E+10 | 0.408552E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.499349E+09 | 0.136798E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.884625E+09 | 0.657950E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.162421E+09 | 68098831.84 | 94322036.06 | 73246390.67 | 0.488420E+09 |
| February | 0.229985E+09 | 98545815.50 | 0.131439E+09 | 0.153794E+09 | 0.343242E+09 |
| March | 0.346378E+09 | 0.173514E+09 | 0.172864E+09 | 0.288971E+09 | 0.289574E+09 |
| April | 0.463579E+09 | 0.249916E+09 | 0.213663E+09 | 0.477549E+09 | 0.175333E+09 |
| May | 0.519805E+09 | 0.228875E+09 | 0.290929E+09 | 0.587647E+09 | 0.112135E+09 |
| June | 0.568839E+09 | 0.272273E+09 | 0.296566E+09 | 0.682469E+09 | 84819695.39 |
| July | 0.577145E+09 | 0.271781E+09 | 0.305364E+09 | 0.697726E+09 | 89296154.60 |
| August | 0.443315E+09 | 0.193421E+09 | 0.249894E+09 | 0.515645E+09 | 0.106311E+09 |
| September | 0.344581E+09 | 0.154451E+09 | 0.190129E+09 | 0.359543E+09 | 0.149995E+09 |
| October | 0.214427E+09 | 80734764.76 | 0.133692E+09 | 0.175843E+09 | 0.210119E+09 |
| November | 0.132742E+09 | 44208928.19 | 88532979.43 | 74639525.83 | 0.278398E+09 |
| December | 0.125923E+09 | 47027250.96 | 78895525.55 | 46069183.46 | 0.472331E+09 |
| Annual Sum or Average | 0.412914E+10 | 0.188285E+10 | 0.224629E+10 | 0.413314E+10 | 0.279997E+10 |
| Minimum of Months | 0.125923E+09 | 44208928.19 | 78895525.55 | 46069183.46 | 84819695.39 |
| Maximum of Months | 0.577145E+09 | 0.272273E+09 | 0.305364E+09 | 0.697726E+09 | 0.488420E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.162421E+09 | 68098831.84 | 94322036.06 | 67348794.10 | 0.541831E+09 |
| February | 0.229985E+09 | 98545815.50 | 0.131439E+09 | 0.145172E+09 | 0.381100E+09 |
| March | 0.346378E+09 | 0.173514E+09 | 0.172864E+09 | 0.279714E+09 | 0.323801E+09 |
| April | 0.463579E+09 | 0.249916E+09 | 0.213663E+09 | 0.475105E+09 | 0.184530E+09 |
| May | 0.519805E+09 | 0.228875E+09 | 0.290929E+09 | 0.598149E+09 | 0.101897E+09 |
| June | 0.568839E+09 | 0.272273E+09 | 0.296566E+09 | 0.694008E+09 | 72805921.42 |
| July | 0.577145E+09 | 0.271781E+09 | 0.305364E+09 | 0.716644E+09 | 70844927.08 |
| August | 0.443315E+09 | 0.193421E+09 | 0.249894E+09 | 0.529941E+09 | 85854882.93 |
| September | 0.344581E+09 | 0.154451E+09 | 0.190129E+09 | 0.371843E+09 | 0.130519E+09 |
| October | 0.214427E+09 | 80734764.76 | 0.133692E+09 | 0.179719E+09 | 0.202733E+09 |
| November | 0.132742E+09 | 44208928.19 | 88532979.43 | 69204886.55 | 0.311319E+09 |
| December | 0.125923E+09 | 47027250.96 | 78895525.55 | 41698937.74 | 0.526672E+09 |
| Annual Sum or Average | 0.412914E+10 | 0.188285E+10 | 0.224629E+10 | 0.416855E+10 | 0.293391E+10 |
| Minimum of Months | 0.125923E+09 | 44208928.19 | 78895525.55 | 41698937.74 | 70844927.08 |
| Maximum of Months | 0.577145E+09 | 0.272273E+09 | 0.305364E+09 | 0.716644E+09 | 0.541831E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 1324596.45 | 0.915710E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 16100508.28 | 0.645112E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 48826802.26 | 0.539470E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.160283E+09 | 0.296183E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.386838E+09 | 0.153712E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.477771E+09 | 0.108147E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.485389E+09 | 0.106291E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.335101E+09 | 0.130810E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.193526E+09 | 0.207540E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 79629235.66 | 0.325912E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 12586991.80 | 0.511757E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 41249.73 | 0.878389E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.219742E+10 | 0.481903E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 41249.73 | 0.106291E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.485389E+09 | 0.915710E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 1190056.85 | 0.927401E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 15472435.91 | 0.653911E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 47843363.89 | 0.547618E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.159995E+09 | 0.300620E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.386809E+09 | 0.156827E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.479379E+09 | 0.110125E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.488692E+09 | 0.106473E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.337207E+09 | 0.131544E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.193225E+09 | 0.212180E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 78724486.38 | 0.330995E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 12109281.33 | 0.518993E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 26039.98 | 0.889549E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.220067E+10 | 0.488624E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 26039.98 | 0.106473E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.488692E+09 | 0.927401E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 1189965.41 | 0.927404E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 15468275.05 | 0.653902E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 47829387.54 | 0.547603E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.159959E+09 | 0.300586E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.386859E+09 | 0.156710E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.479115E+09 | 0.110231E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.488679E+09 | 0.106438E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.337176E+09 | 0.131525E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.193149E+09 | 0.212179E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 78724618.50 | 0.330922E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 12106098.81 | 0.518996E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 26033.63 | 0.889554E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.220028E+10 | 0.488605E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 26033.63 | 0.106438E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.488679E+09 | 0.927404E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.666833E+09 | 0.745865E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.858672E+09 | 0.560044E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.852518E+09 | 0.500839E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.831440E+09 | 0.309663E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.786381E+09 | 0.178102E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.714276E+09 | 0.121425E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.844777E+09 | 0.115714E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.852003E+09 | 0.139522E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.817503E+09 | 0.220391E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.663550E+09 | 0.328681E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.499692E+09 | 0.457918E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.476918E+09 | 0.722750E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.886456E+10 | 0.440091E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.476918E+09 | 0.115714E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.858672E+09 | 0.745865E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.667797E+09 | 0.743060E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.859757E+09 | 0.557664E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.853549E+09 | 0.498427E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.832053E+09 | 0.308443E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.785703E+09 | 0.178530E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.712931E+09 | 0.122470E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.843524E+09 | 0.116743E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.850981E+09 | 0.140615E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.816628E+09 | 0.221548E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.663490E+09 | 0.328630E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.500542E+09 | 0.455526E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.477712E+09 | 0.719952E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.886467E+10 | 0.439161E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.477712E+09 | 0.116743E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.859757E+09 | 0.743060E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.660951E+09 | 0.755741E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.850163E+09 | 0.570125E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.841011E+09 | 0.516766E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.813398E+09 | 0.332003E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.765638E+09 | 0.197343E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.702355E+09 | 0.128883E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.837552E+09 | 0.118617E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.846766E+09 | 0.141312E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.814151E+09 | 0.220708E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.659868E+09 | 0.330722E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.495867E+09 | 0.462995E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.472738E+09 | 0.731526E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.876046E+10 | 0.450674E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.472738E+09 | 0.118617E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.850163E+09 | 0.755741E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.164958E+09 | 69549419.71 | 95408477.45 | 70789780.27 | 0.575012E+09 |
| February | 0.240892E+09 | 0.110089E+09 | 0.130803E+09 | 0.159940E+09 | 0.415116E+09 |
| March | 0.350925E+09 | 0.179876E+09 | 0.171048E+09 | 0.284233E+09 | 0.358149E+09 |
| April | 0.432766E+09 | 0.219151E+09 | 0.213615E+09 | 0.420164E+09 | 0.215693E+09 |
| May | 0.550658E+09 | 0.263092E+09 | 0.287566E+09 | 0.622898E+09 | 0.125309E+09 |
| June | 0.513421E+09 | 0.222117E+09 | 0.291304E+09 | 0.614146E+09 | 82113205.38 |
| July | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.701751E+09 | 76382402.42 |
| August | 0.464729E+09 | 0.210452E+09 | 0.254278E+09 | 0.556036E+09 | 91619347.68 |
| September | 0.352288E+09 | 0.157978E+09 | 0.194309E+09 | 0.375154E+09 | 0.144545E+09 |
| October | 0.230337E+09 | 92544862.74 | 0.137792E+09 | 0.194074E+09 | 0.225199E+09 |
| November | 0.135993E+09 | 46332842.64 | 89659854.57 | 72122008.60 | 0.332278E+09 |
| December | 0.124105E+09 | 43172232.58 | 80932824.48 | 39147665.50 | 0.556197E+09 |
| Annual Sum or Average | 0.412853E+10 | 0.187882E+10 | 0.224971E+10 | 0.411046E+10 | 0.319761E+10 |
| Minimum of Months | 0.124105E+09 | 43172232.58 | 80932824.48 | 39147665.50 | 76382402.42 |
| Maximum of Months | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.701751E+09 | 0.575012E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.164958E+09 | 69549419.71 | 95408477.45 | 72668789.38 | 0.569677E+09 |
| February | 0.240892E+09 | 0.110089E+09 | 0.130803E+09 | 0.163858E+09 | 0.409368E+09 |
| March | 0.350925E+09 | 0.179876E+09 | 0.171048E+09 | 0.289650E+09 | 0.351982E+09 |
| April | 0.432766E+09 | 0.219151E+09 | 0.213615E+09 | 0.428830E+09 | 0.208704E+09 |
| May | 0.550658E+09 | 0.263092E+09 | 0.287566E+09 | 0.626655E+09 | 0.123325E+09 |
| June | 0.513421E+09 | 0.222117E+09 | 0.291304E+09 | 0.615445E+09 | 81836008.95 |
| July | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.703568E+09 | 75875713.38 |
| August | 0.464729E+09 | 0.210452E+09 | 0.254278E+09 | 0.558729E+09 | 90538663.37 |
| September | 0.352288E+09 | 0.157978E+09 | 0.194309E+09 | 0.380408E+09 | 0.140348E+09 |
| October | 0.230337E+09 | 92544862.74 | 0.137792E+09 | 0.200585E+09 | 0.216234E+09 |
| November | 0.135993E+09 | 46332842.64 | 89659854.57 | 74394871.93 | 0.328147E+09 |
| December | 0.124105E+09 | 43172232.58 | 80932824.48 | 40370864.22 | 0.552003E+09 |
| Annual Sum or Average | 0.412853E+10 | 0.187882E+10 | 0.224971E+10 | 0.415516E+10 | 0.314804E+10 |
| Minimum of Months | 0.124105E+09 | 43172232.58 | 80932824.48 | 40370864.22 | 75875713.38 |
| Maximum of Months | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.703568E+09 | 0.569677E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 957307.50 | 0.943042E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 13858466.41 | 0.669003E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 43297257.28 | 0.566885E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.144708E+09 | 0.321708E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.358568E+09 | 0.176878E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.464835E+09 | 0.117664E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.480982E+09 | 0.109680E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.331947E+09 | 0.134282E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.189202E+09 | 0.216831E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 75073990.93 | 0.339051E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 11347181.47 | 0.527159E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 8600.05 | 0.902921E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.211478E+10 | 0.502510E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 8600.05 | 0.109680E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.480982E+09 | 0.943042E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.660553E+09 | 0.755463E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.849719E+09 | 0.569433E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.839948E+09 | 0.515467E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.810635E+09 | 0.331218E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.764402E+09 | 0.196128E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.700813E+09 | 0.128344E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.836561E+09 | 0.117733E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.846169E+09 | 0.140549E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.813358E+09 | 0.219793E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.659467E+09 | 0.329655E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.495576E+09 | 0.462754E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.472423E+09 | 0.731379E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.874962E+10 | 0.449792E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.472423E+09 | 0.117733E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.849719E+09 | 0.755463E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.162421E+09 | 68098831.84 | 94322036.06 | 64035630.13 | 0.564167E+09 |
| February | 0.229985E+09 | 98545815.50 | 0.131439E+09 | 0.138392E+09 | 0.401207E+09 |
| March | 0.346378E+09 | 0.173514E+09 | 0.172864E+09 | 0.268487E+09 | 0.346115E+09 |
| April | 0.463579E+09 | 0.249916E+09 | 0.213663E+09 | 0.453068E+09 | 0.206762E+09 |
| May | 0.519805E+09 | 0.228875E+09 | 0.290929E+09 | 0.574614E+09 | 0.118979E+09 |
| June | 0.568839E+09 | 0.272273E+09 | 0.296566E+09 | 0.682976E+09 | 79431036.56 |
| July | 0.577145E+09 | 0.271781E+09 | 0.305364E+09 | 0.710946E+09 | 73216385.90 |
| August | 0.443315E+09 | 0.193421E+09 | 0.249894E+09 | 0.524224E+09 | 88838622.41 |
| September | 0.344581E+09 | 0.154451E+09 | 0.190129E+09 | 0.362241E+09 | 0.139838E+09 |
| October | 0.214427E+09 | 80734764.76 | 0.133692E+09 | 0.169253E+09 | 0.219260E+09 |
| November | 0.132742E+09 | 44208928.19 | 88532979.43 | 65592614.72 | 0.325209E+09 |
| December | 0.125923E+09 | 47027250.96 | 78895525.55 | 39750562.89 | 0.546383E+09 |
| Annual Sum or Average | 0.412914E+10 | 0.188285E+10 | 0.224629E+10 | 0.405358E+10 | 0.310941E+10 |
| Minimum of Months | 0.125923E+09 | 44208928.19 | 78895525.55 | 39750562.89 | 73216385.90 |
| Maximum of Months | 0.577145E+09 | 0.272273E+09 | 0.305364E+09 | 0.710946E+09 | 0.564167E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.162421E+09 | 68098831.84 | 94322036.06 | 65091980.87 | 0.558130E+09 |
| February | 0.229985E+09 | 98545815.50 | 0.131439E+09 | 0.141067E+09 | 0.394504E+09 |
| March | 0.346378E+09 | 0.173514E+09 | 0.172864E+09 | 0.273037E+09 | 0.339064E+09 |
| April | 0.463579E+09 | 0.249916E+09 | 0.213663E+09 | 0.461791E+09 | 0.199223E+09 |
| May | 0.519805E+09 | 0.228875E+09 | 0.290929E+09 | 0.578314E+09 | 0.116947E+09 |
| June | 0.568839E+09 | 0.272273E+09 | 0.296566E+09 | 0.684288E+09 | 79116522.46 |
| July | 0.577145E+09 | 0.271781E+09 | 0.305364E+09 | 0.712773E+09 | 72674062.41 |
| August | 0.443315E+09 | 0.193421E+09 | 0.249894E+09 | 0.526899E+09 | 87728955.96 |
| September | 0.344581E+09 | 0.154451E+09 | 0.190129E+09 | 0.367237E+09 | 0.135751E+09 |
| October | 0.214427E+09 | 80734764.76 | 0.133692E+09 | 0.175602E+09 | 0.210052E+09 |
| November | 0.132742E+09 | 44208928.19 | 88532979.43 | 67148993.88 | 0.320503E+09 |
| December | 0.125923E+09 | 47027250.96 | 78895525.55 | 40345948.15 | 0.541644E+09 |
| Annual Sum or Average | 0.412914E+10 | 0.188285E+10 | 0.224629E+10 | 0.409359E+10 | 0.305534E+10 |
| Minimum of Months | 0.125923E+09 | 44208928.19 | 78895525.55 | 40345948.15 | 72674062.41 |
| Maximum of Months | 0.577145E+09 | 0.272273E+09 | 0.305364E+09 | 0.712773E+09 | 0.558130E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 955765.39 | 0.943107E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 13731608.09 | 0.668781E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 42858877.73 | 0.566120E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.142743E+09 | 0.320595E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.357109E+09 | 0.175747E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.463179E+09 | 0.117115E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.480004E+09 | 0.108866E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.331253E+09 | 0.133549E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.187818E+09 | 0.215945E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 74699682.42 | 0.337817E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 11268645.24 | 0.527176E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 8453.55 | 0.903058E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.210563E+10 | 0.501787E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 8453.55 | 0.108866E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.480004E+09 | 0.943107E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 880719.15 | 0.953243E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 13407286.61 | 0.675957E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 42721440.03 | 0.571815E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.145504E+09 | 0.322899E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.360435E+09 | 0.177166E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.467495E+09 | 0.117358E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.484820E+09 | 0.108467E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.334208E+09 | 0.133894E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.187730E+09 | 0.221204E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 73686204.35 | 0.344391E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 10836062.83 | 0.534711E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 3372.26 | 0.913314E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.212173E+10 | 0.507442E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 3372.26 | 0.108467E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.484820E+09 | 0.953243E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 880633.94 | 0.953245E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 13401884.71 | 0.675942E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 42701926.03 | 0.571773E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.145382E+09 | 0.322870E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.360327E+09 | 0.177144E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.467433E+09 | 0.117347E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.484791E+09 | 0.108439E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.334180E+09 | 0.133871E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.187660E+09 | 0.221167E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 73683215.34 | 0.344272E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 10832120.93 | 0.534716E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 3372.53 | 0.913319E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.212128E+10 | 0.507411E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 3372.53 | 0.108439E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.484791E+09 | 0.953245E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.657692E+09 | 0.765037E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.847237E+09 | 0.577013E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.838895E+09 | 0.522498E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.811440E+09 | 0.336230E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.766667E+09 | 0.198030E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.704846E+09 | 0.128478E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.841005E+09 | 0.117271E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.848777E+09 | 0.140888E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.812835E+09 | 0.224681E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.656720E+09 | 0.338460E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.493234E+09 | 0.470144E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.470074E+09 | 0.741041E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.874942E+10 | 0.455977E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.470074E+09 | 0.117271E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.848777E+09 | 0.765037E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.657677E+09 | 0.765029E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.847216E+09 | 0.576974E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.838844E+09 | 0.522437E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.811284E+09 | 0.336247E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.766595E+09 | 0.197995E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.704789E+09 | 0.128465E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.840974E+09 | 0.117240E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.848755E+09 | 0.140862E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.812821E+09 | 0.224625E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.656727E+09 | 0.338366E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.493215E+09 | 0.470139E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.470063E+09 | 0.741037E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.874896E+10 | 0.455942E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.470063E+09 | 0.117240E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.848755E+09 | 0.765029E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.663472E+09 | 0.738168E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.850331E+09 | 0.555804E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.840390E+09 | 0.502136E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.814491E+09 | 0.316297E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.768780E+09 | 0.182963E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.702171E+09 | 0.119908E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.833615E+09 | 0.113194E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.845322E+09 | 0.132939E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.820258E+09 | 0.199977E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.664006E+09 | 0.311060E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.497211E+09 | 0.448752E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.475061E+09 | 0.714168E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.877511E+10 | 0.433537E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.475061E+09 | 0.113194E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.850331E+09 | 0.738168E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.164958E+09 | 69549419.71 | 95408477.45 | 70818113.89 | 0.561643E+09 |
| February | 0.240892E+09 | 0.110089E+09 | 0.130803E+09 | 0.158987E+09 | 0.404377E+09 |
| March | 0.350925E+09 | 0.179876E+09 | 0.171048E+09 | 0.282711E+09 | 0.347272E+09 |
| April | 0.432766E+09 | 0.219151E+09 | 0.213615E+09 | 0.420071E+09 | 0.204498E+09 |
| May | 0.550658E+09 | 0.263092E+09 | 0.287566E+09 | 0.624940E+09 | 0.115618E+09 |
| June | 0.513421E+09 | 0.222117E+09 | 0.291304E+09 | 0.613949E+09 | 76038240.40 |
| July | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.698970E+09 | 72612811.27 |
| August | 0.464729E+09 | 0.210452E+09 | 0.254278E+09 | 0.555094E+09 | 85897816.63 |
| September | 0.352288E+09 | 0.157978E+09 | 0.194309E+09 | 0.378706E+09 | 0.130251E+09 |
| October | 0.230337E+09 | 92544862.74 | 0.137792E+09 | 0.195862E+09 | 0.211122E+09 |
| November | 0.135993E+09 | 46332842.64 | 89659854.57 | 72145172.26 | 0.321791E+09 |
| December | 0.124105E+09 | 43172232.58 | 80932824.48 | 39197370.56 | 0.543177E+09 |
| Annual Sum or Average | 0.412853E+10 | 0.187882E+10 | 0.224971E+10 | 0.411145E+10 | 0.307430E+10 |
| Minimum of Months | 0.124105E+09 | 43172232.58 | 80932824.48 | 39197370.56 | 72612811.27 |
| Maximum of Months | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.698970E+09 | 0.561643E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.164958E+09 | 69549419.71 | 95408477.45 | 73562183.87 | 0.556593E+09 |
| February | 0.240892E+09 | 0.110089E+09 | 0.130803E+09 | 0.164761E+09 | 0.399153E+09 |
| March | 0.350925E+09 | 0.179876E+09 | 0.171048E+09 | 0.290434E+09 | 0.342110E+09 |
| April | 0.432766E+09 | 0.219151E+09 | 0.213615E+09 | 0.429386E+09 | 0.200727E+09 |
| May | 0.550658E+09 | 0.263092E+09 | 0.287566E+09 | 0.629786E+09 | 0.114388E+09 |
| June | 0.513421E+09 | 0.222117E+09 | 0.291304E+09 | 0.615567E+09 | 75915184.11 |
| July | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.701353E+09 | 72311431.21 |
| August | 0.464729E+09 | 0.210452E+09 | 0.254278E+09 | 0.559104E+09 | 84799086.28 |
| September | 0.352288E+09 | 0.157978E+09 | 0.194309E+09 | 0.386328E+09 | 0.126596E+09 |
| October | 0.230337E+09 | 92544862.74 | 0.137792E+09 | 0.202926E+09 | 0.206154E+09 |
| November | 0.135993E+09 | 46332842.64 | 89659854.57 | 75394688.89 | 0.318222E+09 |
| December | 0.124105E+09 | 43172232.58 | 80932824.48 | 41024506.53 | 0.539195E+09 |
| Annual Sum or Average | 0.412853E+10 | 0.187882E+10 | 0.224971E+10 | 0.416963E+10 | 0.303616E+10 |
| Minimum of Months | 0.124105E+09 | 43172232.58 | 80932824.48 | 41024506.53 | 72311431.21 |
| Maximum of Months | 0.567458E+09 | 0.264470E+09 | 0.302988E+09 | 0.701353E+09 | 0.556593E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 1079927.51 | 0.922178E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 14638421.75 | 0.653004E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 44525520.04 | 0.552326E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.146309E+09 | 0.310306E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.364922E+09 | 0.164993E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.466659E+09 | 0.110206E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.478985E+09 | 0.105382E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.333500E+09 | 0.126371E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.198394E+09 | 0.196089E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 78527935.35 | 0.323724E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 12153422.47 | 0.511540E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 20389.98 | 0.882696E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.213972E+10 | 0.485882E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 20389.98 | 0.105382E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.478985E+09 | 0.922178E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.662860E+09 | 0.737713E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.849613E+09 | 0.554742E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.838425E+09 | 0.500065E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.810250E+09 | 0.314235E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.765821E+09 | 0.180545E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.698337E+09 | 0.118588E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.831327E+09 | 0.111503E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.843617E+09 | 0.131402E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.817998E+09 | 0.198306E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.663029E+09 | 0.309752E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.496712E+09 | 0.448332E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.474578E+09 | 0.713924E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.875257E+10 | 0.431911E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.474578E+09 | 0.111503E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.849613E+09 | 0.737713E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.162421E+09 | 68098831.84 | 94322036.06 | 65089021.61 | 0.551306E+09 |
| February | 0.229985E+09 | 98545815.50 | 0.131439E+09 | 0.139229E+09 | 0.391673E+09 |
| March | 0.346378E+09 | 0.173514E+09 | 0.172864E+09 | 0.268544E+09 | 0.336710E+09 |
| April | 0.463579E+09 | 0.249916E+09 | 0.213663E+09 | 0.454048E+09 | 0.196591E+09 |
| May | 0.519805E+09 | 0.228875E+09 | 0.290929E+09 | 0.577221E+09 | 0.110349E+09 |
| June | 0.568839E+09 | 0.272273E+09 | 0.296566E+09 | 0.682302E+09 | 73970407.36 |
| July | 0.577145E+09 | 0.271781E+09 | 0.305364E+09 | 0.708291E+09 | 69768555.39 |
| August | 0.443315E+09 | 0.193421E+09 | 0.249894E+09 | 0.523313E+09 | 83383534.55 |
| September | 0.344581E+09 | 0.154451E+09 | 0.190129E+09 | 0.366644E+09 | 0.126755E+09 |
| October | 0.214427E+09 | 80734764.76 | 0.133692E+09 | 0.172069E+09 | 0.206233E+09 |
| November | 0.132742E+09 | 44208928.19 | 88532979.43 | 66555895.61 | 0.315328E+09 |
| December | 0.125923E+09 | 47027250.96 | 78895525.55 | 40447134.78 | 0.533463E+09 |
| Annual Sum or Average | 0.412914E+10 | 0.188285E+10 | 0.224629E+10 | 0.406375E+10 | 0.299553E+10 |
| Minimum of Months | 0.125923E+09 | 44208928.19 | 78895525.55 | 40447134.78 | 69768555.39 |
| Maximum of Months | 0.577145E+09 | 0.272273E+09 | 0.305364E+09 | 0.708291E+09 | 0.551306E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.162421E+09 | 68098831.84 | 94322036.06 | 66461078.96 | 0.545073E+09 |
| February | 0.229985E+09 | 98545815.50 | 0.131439E+09 | 0.142757E+09 | 0.384631E+09 |
| March | 0.346378E+09 | 0.173514E+09 | 0.172864E+09 | 0.274651E+09 | 0.329662E+09 |
| April | 0.463579E+09 | 0.249916E+09 | 0.213663E+09 | 0.462850E+09 | 0.191783E+09 |
| May | 0.519805E+09 | 0.228875E+09 | 0.290929E+09 | 0.581677E+09 | 0.108825E+09 |
| June | 0.568839E+09 | 0.272273E+09 | 0.296566E+09 | 0.683960E+09 | 73818720.91 |
| July | 0.577145E+09 | 0.271781E+09 | 0.305364E+09 | 0.710795E+09 | 69394338.20 |
| August | 0.443315E+09 | 0.193421E+09 | 0.249894E+09 | 0.527160E+09 | 82241066.34 |
| September | 0.344581E+09 | 0.154451E+09 | 0.190129E+09 | 0.373394E+09 | 0.122852E+09 |
| October | 0.214427E+09 | 80734764.76 | 0.133692E+09 | 0.178462E+09 | 0.200354E+09 |
| November | 0.132742E+09 | 44208928.19 | 88532979.43 | 68505344.30 | 0.310624E+09 |
| December | 0.125923E+09 | 47027250.96 | 78895525.55 | 41261089.47 | 0.528588E+09 |
| Annual Sum or Average | 0.412914E+10 | 0.188285E+10 | 0.224629E+10 | 0.411193E+10 | 0.294785E+10 |
| Minimum of Months | 0.125923E+09 | 44208928.19 | 78895525.55 | 41261089.47 | 69394338.20 |
| Maximum of Months | 0.577145E+09 | 0.272273E+09 | 0.305364E+09 | 0.710795E+09 | 0.545073E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 1073411.97 | 0.922268E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 14412246.25 | 0.652647E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 43709352.18 | 0.550932E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.142937E+09 | 0.308191E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.361720E+09 | 0.162860E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.462822E+09 | 0.109032E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.476958E+09 | 0.103853E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.331536E+09 | 0.124944E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.195002E+09 | 0.194284E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 77611707.78 | 0.322090E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 12021499.95 | 0.511477E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 20100.55 | 0.882884E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.211982E+10 | 0.484546E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 20100.55 | 0.103853E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.476958E+09 | 0.922268E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 981790.23 | 0.934432E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 14164924.34 | 0.661135E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 44041156.41 | 0.557819E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.147663E+09 | 0.311841E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.367631E+09 | 0.166337E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.468833E+09 | 0.111646E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.482881E+09 | 0.105393E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.335321E+09 | 0.128089E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.198487E+09 | 0.199236E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 78092211.17 | 0.327585E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 11683172.17 | 0.519530E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 11403.50 | 0.895081E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.214979E+10 | 0.491813E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 11403.50 | 0.105393E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.482881E+09 | 0.934432E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.111995E+09 | 0.00 | 0.111995E+09 | 981379.93 | 0.934435E+09 |
| February | 0.155385E+09 | 0.00 | 0.155385E+09 | 14150760.69 | 0.661110E+09 |
| March | 0.211714E+09 | 15171.03 | 0.211698E+09 | 43984840.29 | 0.557725E+09 |
| April | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.147368E+09 | 0.311703E+09 |
| May | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.367303E+09 | 0.166190E+09 |
| June | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.468567E+09 | 0.111577E+09 |
| July | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.482792E+09 | 0.105288E+09 |
| August | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.335191E+09 | 0.127995E+09 |
| September | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.198155E+09 | 0.199142E+09 |
| October | 0.170963E+09 | 0.00 | 0.170963E+09 | 78004669.24 | 0.327448E+09 |
| November | 0.109547E+09 | 0.00 | 0.109547E+09 | 11675053.14 | 0.519525E+09 |
| December | 94891471.55 | 0.00 | 94891471.55 | 11387.20 | 0.895088E+09 |
| Annual Sum or Average | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.214818E+10 | 0.491723E+10 |
| Minimum of Months | 94891471.55 | 0.00 | 94891471.55 | 11387.20 | 0.105288E+09 |
| Maximum of Months | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.482792E+09 | 0.934435E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.659899E+09 | 0.748230E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.847301E+09 | 0.563347E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.838293E+09 | 0.508392E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.813339E+09 | 0.320033E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.770132E+09 | 0.184703E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.704250E+09 | 0.121433E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.837170E+09 | 0.113235E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.846829E+09 | 0.134727E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.819176E+09 | 0.204689E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.662228E+09 | 0.317080E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.494620E+09 | 0.456299E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.472060E+09 | 0.724510E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.876530E+10 | 0.439668E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.472060E+09 | 0.113235E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.847301E+09 | 0.748230E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.659864E+09 | 0.748204E+09 |
| February | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.847242E+09 | 0.563260E+09 |
| March | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.838141E+09 | 0.508245E+09 |
| April | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.813022E+09 | 0.319903E+09 |
| May | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.769897E+09 | 0.184524E+09 |
| June | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.704000E+09 | 0.121348E+09 |
| July | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.837053E+09 | 0.113115E+09 |
| August | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.846732E+09 | 0.134622E+09 |
| September | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.819040E+09 | 0.204550E+09 |
| October | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.662169E+09 | 0.316953E+09 |
| November | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.494578E+09 | 0.456271E+09 |
| December | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.472035E+09 | 0.724496E+09 |
| Annual Sum or Average | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.876377E+10 | 0.439549E+10 |
| Minimum of Months | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.472035E+09 | 0.113115E+09 |
| Maximum of Months | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.847242E+09 | 0.748204E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 38973548.37 | 16340591.89 | 22632956.48 | 15798916.71 | 0.132034E+09 |
| February | 55185765.92 | 23646469.55 | 31539296.37 | 33698477.33 | 94410824.85 |
| March | 83114789.83 | 41635478.20 | 41479311.63 | 64841193.88 | 82377089.06 |
| April | 0.111238E+09 | 59968388.59 | 51269281.63 | 0.109106E+09 | 49699204.14 |
| May | 0.124729E+09 | 54919603.03 | 69809609.86 | 0.136718E+09 | 29682315.37 |
| June | 0.136495E+09 | 65333035.87 | 71162298.18 | 0.161023E+09 | 20641290.90 |
| July | 0.138488E+09 | 65214865.22 | 73273391.62 | 0.167126E+09 | 19580700.89 |
| August | 0.106375E+09 | 46412274.88 | 59963054.04 | 0.123445E+09 | 23291069.40 |
| September | 82683514.98 | 37061203.23 | 45622311.75 | 87194384.05 | 33766957.00 |
| October | 51452582.22 | 19372635.43 | 32079946.79 | 41173122.94 | 52287648.43 |
| November | 31851961.04 | 10608112.27 | 21243848.78 | 15845527.08 | 77373663.25 |
| December | 30215682.78 | 11284380.29 | 18931302.49 | 9799954.28 | 0.128172E+09 |
| Annual Sum or Average | 0.990804E+09 | 0.451797E+09 | 0.539007E+09 | 0.965769E+09 | 0.743317E+09 |
| Minimum of Months | 30215682.78 | 10608112.27 | 18931302.49 | 9799954.28 | 19580700.89 |
| Maximum of Months | 0.138488E+09 | 65333035.87 | 73273391.62 | 0.167126E+09 | 0.132034E+09 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.116073E+09 | 48666349.22 | 67406576.91 | 54590532.83 | 0.340738E+09 |
| February | 0.164357E+09 | 70425071.06 | 93931873.56 | 0.111914E+09 | 0.245552E+09 |
| March | 0.247537E+09 | 0.124001E+09 | 0.123536E+09 | 0.207914E+09 | 0.212325E+09 |
| April | 0.331293E+09 | 0.178601E+09 | 0.152693E+09 | 0.341307E+09 | 0.130535E+09 |
| May | 0.371475E+09 | 0.163564E+09 | 0.207910E+09 | 0.420629E+09 | 79963039.87 |
| June | 0.406517E+09 | 0.194578E+09 | 0.211939E+09 | 0.486157E+09 | 59057099.92 |
| July | 0.412452E+09 | 0.194226E+09 | 0.218226E+09 | 0.499789E+09 | 59165051.85 |
| August | 0.316812E+09 | 0.138227E+09 | 0.178585E+09 | 0.370012E+09 | 70145668.01 |
| September | 0.246252E+09 | 0.110377E+09 | 0.135875E+09 | 0.260809E+09 | 0.101287E+09 |
| October | 0.153239E+09 | 57696529.44 | 95542065.08 | 0.127825E+09 | 0.146443E+09 |
| November | 94863066.78 | 31593598.30 | 63269468.48 | 52613104.80 | 0.205472E+09 |
| December | 89989822.89 | 33607692.76 | 56382130.13 | 34223548.91 | 0.332070E+09 |
| Annual Sum or Average | 0.295086E+10 | 0.134556E+10 | 0.160530E+10 | 0.296778E+10 | 0.198275E+10 |
| Minimum of Months | 89989822.89 | 31593598.30 | 56382130.13 | 34223548.91 | 59057099.92 |
| Maximum of Months | 0.412452E+09 | 0.194578E+09 | 0.218226E+09 | 0.499789E+09 | 0.340738E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 38973548.37 | 16340591.89 | 22632956.48 | 14922823.65 | 0.139467E+09 |
| February | 55185765.92 | 23646469.55 | 31539296.37 | 32477491.72 | 99766525.84 |
| March | 83114789.83 | 41635478.20 | 41479311.63 | 63385570.34 | 87061402.03 |
| April | 0.111238E+09 | 59968388.59 | 51269281.63 | 0.107359E+09 | 52764412.85 |
| May | 0.124729E+09 | 54919603.03 | 69809609.86 | 0.134761E+09 | 31485960.82 |
| June | 0.136495E+09 | 65333035.87 | 71162298.18 | 0.160273E+09 | 21681955.30 |
| July | 0.138488E+09 | 65214865.22 | 73273391.62 | 0.166991E+09 | 20174699.92 |
| August | 0.106375E+09 | 46412274.88 | 59963054.04 | 0.122819E+09 | 24390344.19 |
| September | 82683514.98 | 37061203.23 | 45622311.75 | 84777099.31 | 37064358.89 |
| October | 51452582.22 | 19372635.43 | 32079946.79 | 39401054.84 | 56449696.84 |
| November | 31851961.04 | 10608112.27 | 21243848.78 | 15027240.77 | 82427496.98 |
| December | 30215682.78 | 11284380.29 | 18931302.49 | 9233499.96 | 0.135551E+09 |
| Annual Sum or Average | 0.990804E+09 | 0.451797E+09 | 0.539007E+09 | 0.951427E+09 | 0.788285E+09 |
| Minimum of Months | 30215682.78 | 10608112.27 | 18931302.49 | 9233499.96 | 20174699.92 |
| Maximum of Months | 0.138488E+09 | 65333035.87 | 73273391.62 | 0.166991E+09 | 0.139467E+09 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 256.36 | 461.91 | 349.84 | 226.35 | 123.49 | 0.00 | 0.00 |
| February | 412.49 | 381.93 | 463.36 | 290.95 | 172.41 | 0.00 | 0.00 |
| March | 421.60 | 304.47 | 448.20 | 266.41 | 181.79 | 0.00 | 0.00 |
| April | 486.20 | 190.65 | 458.32 | 242.82 | 215.50 | 0.00 | 0.00 |
| May | 531.20 | 106.04 | 452.16 | 183.76 | 268.40 | 0.00 | 0.00 |
| June | 515.42 | 73.97 | 418.13 | 144.71 | 273.43 | 0.00 | 0.00 |
| July | 577.16 | 70.66 | 454.76 | 177.62 | 277.14 | 0.00 | 0.00 |
| August | 525.69 | 85.29 | 427.01 | 182.94 | 244.07 | 0.00 | 0.00 |
| September | 460.92 | 136.81 | 407.11 | 203.78 | 203.33 | 0.00 | 0.00 |
| October | 320.59 | 199.48 | 323.46 | 175.41 | 148.05 | 0.00 | 0.00 |
| November | 216.20 | 292.22 | 260.61 | 148.12 | 112.49 | 0.00 | 0.00 |
| December | 175.71 | 449.52 | 268.98 | 162.18 | 106.80 | 0.00 | 0.00 |
| Annual Sum or Average | 408.14 | 228.77 | 393.85 | 199.85 | 194.00 | 0.00 | 0.00 |
| Minimum of Months | 175.71 | 70.66 | 260.61 | 144.71 | 106.80 | 0.00 | 0.00 |
| Maximum of Months | 577.16 | 461.91 | 463.36 | 290.95 | 277.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 12.38 | 532.07 | 103.40 | 25.97 | 77.44 | 0.00 | 0.00 |
| February | 63.31 | 417.30 | 163.81 | 45.51 | 118.30 | 0.00 | 0.00 |
| March | 120.71 | 318.85 | 210.07 | 67.16 | 142.90 | 0.00 | 0.00 |
| April | 230.61 | 187.18 | 270.79 | 85.57 | 185.22 | 0.00 | 0.00 |
| May | 383.58 | 96.82 | 351.43 | 106.08 | 245.35 | 0.00 | 0.00 |
| June | 425.65 | 69.21 | 360.62 | 103.48 | 257.14 | 0.00 | 0.00 |
| July | 444.54 | 66.51 | 367.00 | 111.86 | 255.14 | 0.00 | 0.00 |
| August | 334.75 | 81.76 | 291.90 | 80.97 | 210.94 | 0.00 | 0.00 |
| September | 222.73 | 131.40 | 227.94 | 61.01 | 166.92 | 0.00 | 0.00 |
| October | 104.26 | 197.91 | 149.83 | 34.55 | 115.28 | 0.00 | 0.00 |
| November | 28.03 | 313.93 | 94.73 | 17.88 | 76.85 | 0.00 | 0.00 |
| December | 4.17 | 516.64 | 81.76 | 16.12 | 65.65 | 0.00 | 0.00 |
| Annual Sum or Average | 198.68 | 243.46 | 223.08 | 63.11 | 159.97 | 0.00 | 0.00 |
| Minimum of Months | 4.17 | 66.51 | 81.76 | 16.12 | 65.65 | 0.00 | 0.00 |
| Maximum of Months | 444.54 | 532.07 | 367.00 | 111.86 | 257.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 268.42 | 410.24 | 348.89 | 225.81 | 123.08 | 0.00 | 0.00 |
| February | 420.84 | 336.61 | 458.85 | 286.18 | 172.67 | 0.00 | 0.00 |
| March | 429.27 | 264.72 | 446.51 | 264.04 | 182.47 | 0.00 | 0.00 |
| April | 504.88 | 170.66 | 470.21 | 254.69 | 215.52 | 0.00 | 0.00 |
| May | 507.06 | 106.35 | 440.64 | 170.99 | 269.65 | 0.00 | 0.00 |
| June | 530.74 | 82.92 | 439.52 | 164.06 | 275.46 | 0.00 | 0.00 |
| July | 563.48 | 84.62 | 458.38 | 180.35 | 278.03 | 0.00 | 0.00 |
| August | 502.18 | 100.73 | 419.02 | 176.58 | 242.44 | 0.00 | 0.00 |
| September | 448.74 | 146.36 | 404.14 | 202.42 | 201.72 | 0.00 | 0.00 |
| October | 314.48 | 195.12 | 317.52 | 171.00 | 146.52 | 0.00 | 0.00 |
| November | 224.37 | 257.23 | 259.36 | 147.30 | 112.05 | 0.00 | 0.00 |
| December | 189.10 | 399.06 | 269.66 | 163.62 | 106.04 | 0.00 | 0.00 |
| Annual Sum or Average | 408.33 | 212.40 | 393.87 | 199.98 | 193.90 | 0.00 | 0.00 |
| Minimum of Months | 189.10 | 82.92 | 259.36 | 147.30 | 106.04 | 0.00 | 0.00 |
| Maximum of Months | 563.48 | 410.24 | 470.21 | 286.18 | 278.03 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 7.35 | 525.89 | 102.46 | 25.43 | 77.03 | 0.00 | 0.00 |
| February | 48.99 | 406.52 | 159.30 | 40.73 | 118.56 | 0.00 | 0.00 |
| March | 109.26 | 308.91 | 208.37 | 64.79 | 143.58 | 0.00 | 0.00 |
| April | 239.24 | 179.57 | 282.67 | 97.44 | 185.24 | 0.00 | 0.00 |
| May | 366.89 | 94.57 | 339.91 | 93.31 | 246.60 | 0.00 | 0.00 |
| June | 451.36 | 69.10 | 382.00 | 122.83 | 259.17 | 0.00 | 0.00 |
| July | 448.33 | 65.68 | 370.62 | 114.59 | 256.03 | 0.00 | 0.00 |
| August | 322.45 | 80.37 | 283.91 | 74.61 | 209.30 | 0.00 | 0.00 |
| September | 215.54 | 127.84 | 224.96 | 59.65 | 165.31 | 0.00 | 0.00 |
| October | 93.13 | 193.68 | 143.89 | 30.14 | 113.74 | 0.00 | 0.00 |
| November | 24.81 | 310.80 | 93.48 | 17.06 | 76.42 | 0.00 | 0.00 |
| December | 3.06 | 512.06 | 82.44 | 17.56 | 64.88 | 0.00 | 0.00 |
| Annual Sum or Average | 194.97 | 238.95 | 223.10 | 63.24 | 159.86 | 0.00 | 0.00 |
| Minimum of Months | 3.06 | 65.68 | 82.44 | 17.06 | 64.88 | 0.00 | 0.00 |
| Maximum of Months | 451.36 | 525.89 | 382.00 | 122.83 | 259.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.44 | 346.25 | 41.81 | 0.00 | 41.81 | 0.00 | 0.00 |
| February | 6.40 | 270.30 | 64.23 | 0.00 | 64.23 | 0.00 | 0.00 |
| March | 17.86 | 204.46 | 79.04 | 0.01 | 79.04 | 0.00 | 0.00 |
| April | 61.73 | 115.98 | 103.82 | 1.02 | 102.81 | 0.00 | 0.00 |
| May | 144.42 | 58.55 | 145.83 | 7.85 | 137.98 | 0.00 | 0.00 |
| June | 184.95 | 42.49 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
| July | 182.46 | 39.75 | 155.14 | 13.12 | 142.02 | 0.00 | 0.00 |
| August | 125.90 | 49.11 | 118.39 | 2.39 | 116.00 | 0.00 | 0.00 |
| September | 74.55 | 81.86 | 92.02 | 0.07 | 91.96 | 0.00 | 0.00 |
| October | 29.39 | 123.58 | 63.83 | 0.00 | 63.83 | 0.00 | 0.00 |
| November | 4.67 | 200.23 | 42.26 | 0.00 | 42.26 | 0.00 | 0.00 |
| December | 0.01 | 332.12 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Annual Sum or Average | 69.78 | 154.94 | 92.17 | 3.54 | 88.63 | 0.00 | 0.00 |
| Minimum of Months | 0.01 | 39.75 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Maximum of Months | 184.95 | 346.25 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.44 | 346.25 | 41.81 | 0.00 | 41.81 | 0.00 | 0.00 |
| February | 6.39 | 270.30 | 64.23 | 0.00 | 64.23 | 0.00 | 0.00 |
| March | 17.86 | 204.45 | 79.04 | 0.01 | 79.04 | 0.00 | 0.00 |
| April | 61.71 | 115.97 | 103.82 | 1.02 | 102.81 | 0.00 | 0.00 |
| May | 144.44 | 58.51 | 145.83 | 7.85 | 137.98 | 0.00 | 0.00 |
| June | 184.84 | 42.53 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
| July | 182.45 | 39.74 | 155.14 | 13.12 | 142.02 | 0.00 | 0.00 |
| August | 125.89 | 49.11 | 118.39 | 2.39 | 116.00 | 0.00 | 0.00 |
| September | 74.52 | 81.86 | 92.02 | 0.07 | 91.96 | 0.00 | 0.00 |
| October | 29.39 | 123.55 | 63.83 | 0.00 | 63.83 | 0.00 | 0.00 |
| November | 4.67 | 200.23 | 42.26 | 0.00 | 42.26 | 0.00 | 0.00 |
| December | 0.01 | 332.12 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Annual Sum or Average | 69.77 | 154.94 | 92.17 | 3.54 | 88.63 | 0.00 | 0.00 |
| Minimum of Months | 0.01 | 39.74 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Maximum of Months | 184.84 | 346.25 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 248.97 | 278.47 | 288.25 | 200.38 | 87.87 | 0.00 | 0.00 |
| February | 354.94 | 231.50 | 363.78 | 245.44 | 118.34 | 0.00 | 0.00 |
| March | 318.29 | 186.99 | 317.18 | 199.25 | 117.93 | 0.00 | 0.00 |
| April | 320.77 | 119.47 | 291.36 | 158.27 | 133.09 | 0.00 | 0.00 |
| May | 293.60 | 66.50 | 246.57 | 85.54 | 161.03 | 0.00 | 0.00 |
| June | 275.57 | 46.85 | 220.06 | 59.02 | 161.04 | 0.00 | 0.00 |
| July | 315.40 | 43.20 | 242.90 | 78.88 | 164.02 | 0.00 | 0.00 |
| August | 318.10 | 52.09 | 253.50 | 104.37 | 149.14 | 0.00 | 0.00 |
| September | 315.39 | 85.03 | 271.20 | 142.83 | 128.37 | 0.00 | 0.00 |
| October | 247.74 | 122.72 | 237.46 | 140.86 | 96.60 | 0.00 | 0.00 |
| November | 192.78 | 176.67 | 208.15 | 130.25 | 77.90 | 0.00 | 0.00 |
| December | 178.06 | 269.84 | 222.65 | 146.06 | 76.58 | 0.00 | 0.00 |
| Annual Sum or Average | 281.09 | 139.55 | 262.94 | 140.27 | 122.67 | 0.00 | 0.00 |
| Minimum of Months | 178.06 | 43.20 | 208.15 | 59.02 | 76.58 | 0.00 | 0.00 |
| Maximum of Months | 354.94 | 278.47 | 363.78 | 245.44 | 164.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 249.33 | 277.43 | 288.25 | 200.38 | 87.87 | 0.00 | 0.00 |
| February | 355.39 | 230.52 | 363.78 | 245.44 | 118.34 | 0.00 | 0.00 |
| March | 318.68 | 186.09 | 317.18 | 199.25 | 117.93 | 0.00 | 0.00 |
| April | 321.01 | 119.00 | 291.36 | 158.27 | 133.09 | 0.00 | 0.00 |
| May | 293.35 | 66.66 | 246.57 | 85.54 | 161.03 | 0.00 | 0.00 |
| June | 275.05 | 47.25 | 220.06 | 59.02 | 161.04 | 0.00 | 0.00 |
| July | 314.94 | 43.59 | 242.90 | 78.88 | 164.02 | 0.00 | 0.00 |
| August | 317.72 | 52.50 | 253.50 | 104.37 | 149.14 | 0.00 | 0.00 |
| September | 315.06 | 85.47 | 271.20 | 142.83 | 128.37 | 0.00 | 0.00 |
| October | 247.72 | 122.70 | 237.46 | 140.86 | 96.60 | 0.00 | 0.00 |
| November | 193.11 | 175.74 | 208.15 | 130.25 | 77.90 | 0.00 | 0.00 |
| December | 178.36 | 268.80 | 222.65 | 146.06 | 76.58 | 0.00 | 0.00 |
| Annual Sum or Average | 281.10 | 139.26 | 262.94 | 140.27 | 122.67 | 0.00 | 0.00 |
| Minimum of Months | 178.36 | 43.59 | 208.15 | 59.02 | 76.58 | 0.00 | 0.00 |
| Maximum of Months | 355.39 | 277.43 | 363.78 | 245.44 | 164.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 251.05 | 474.70 | 349.84 | 226.35 | 123.49 | 0.00 | 0.00 |
| February | 404.62 | 394.34 | 463.36 | 290.95 | 172.41 | 0.00 | 0.00 |
| March | 412.25 | 318.79 | 448.20 | 266.41 | 181.79 | 0.00 | 0.00 |
| April | 471.63 | 207.02 | 458.32 | 242.82 | 215.50 | 0.00 | 0.00 |
| May | 516.64 | 118.69 | 452.16 | 183.76 | 268.40 | 0.00 | 0.00 |
| June | 506.53 | 80.02 | 418.13 | 144.71 | 273.43 | 0.00 | 0.00 |
| July | 573.89 | 71.99 | 454.76 | 177.62 | 277.14 | 0.00 | 0.00 |
| August | 523.21 | 86.43 | 427.01 | 182.94 | 244.07 | 0.00 | 0.00 |
| September | 457.61 | 139.69 | 407.11 | 203.78 | 203.33 | 0.00 | 0.00 |
| October | 316.46 | 205.19 | 323.46 | 175.41 | 148.05 | 0.00 | 0.00 |
| November | 212.56 | 300.24 | 260.61 | 148.12 | 112.49 | 0.00 | 0.00 |
| December | 171.97 | 461.63 | 268.98 | 162.18 | 106.80 | 0.00 | 0.00 |
| Annual Sum or Average | 401.39 | 237.56 | 393.85 | 199.85 | 194.00 | 0.00 | 0.00 |
| Minimum of Months | 171.97 | 71.99 | 260.61 | 144.71 | 106.80 | 0.00 | 0.00 |
| Maximum of Months | 573.89 | 474.70 | 463.36 | 290.95 | 277.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 11.26 | 548.56 | 103.40 | 25.97 | 77.44 | 0.00 | 0.00 |
| February | 59.78 | 432.07 | 163.81 | 45.51 | 118.30 | 0.00 | 0.00 |
| March | 115.09 | 333.85 | 210.07 | 67.16 | 142.90 | 0.00 | 0.00 |
| April | 218.70 | 202.07 | 270.79 | 85.57 | 185.22 | 0.00 | 0.00 |
| May | 366.16 | 110.41 | 351.43 | 106.08 | 245.35 | 0.00 | 0.00 |
| June | 415.29 | 75.48 | 360.62 | 103.48 | 257.14 | 0.00 | 0.00 |
| July | 441.08 | 68.10 | 367.00 | 111.86 | 255.14 | 0.00 | 0.00 |
| August | 332.15 | 83.55 | 291.90 | 80.97 | 210.94 | 0.00 | 0.00 |
| September | 218.70 | 136.75 | 227.94 | 61.01 | 166.92 | 0.00 | 0.00 |
| October | 100.70 | 205.10 | 149.83 | 34.55 | 115.28 | 0.00 | 0.00 |
| November | 26.40 | 323.30 | 94.73 | 17.88 | 76.85 | 0.00 | 0.00 |
| December | 3.67 | 531.80 | 81.76 | 16.12 | 65.65 | 0.00 | 0.00 |
| Annual Sum or Average | 193.21 | 253.56 | 223.08 | 63.11 | 159.97 | 0.00 | 0.00 |
| Minimum of Months | 3.67 | 68.10 | 81.76 | 16.12 | 65.65 | 0.00 | 0.00 |
| Maximum of Months | 441.08 | 548.56 | 367.00 | 111.86 | 257.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 250.05 | 472.21 | 348.89 | 225.81 | 123.08 | 0.00 | 0.00 |
| February | 397.64 | 390.42 | 458.85 | 286.18 | 172.67 | 0.00 | 0.00 |
| March | 405.91 | 313.74 | 446.51 | 264.04 | 182.47 | 0.00 | 0.00 |
| April | 480.92 | 200.94 | 470.21 | 254.69 | 215.52 | 0.00 | 0.00 |
| May | 495.15 | 112.87 | 440.64 | 170.99 | 269.65 | 0.00 | 0.00 |
| June | 531.33 | 77.62 | 439.52 | 164.06 | 275.46 | 0.00 | 0.00 |
| July | 575.75 | 69.27 | 458.38 | 180.35 | 278.03 | 0.00 | 0.00 |
| August | 510.05 | 84.05 | 419.02 | 176.58 | 242.44 | 0.00 | 0.00 |
| September | 451.31 | 136.50 | 404.14 | 202.42 | 201.72 | 0.00 | 0.00 |
| October | 307.93 | 203.47 | 317.52 | 171.00 | 146.52 | 0.00 | 0.00 |
| November | 210.53 | 298.03 | 259.36 | 147.30 | 112.05 | 0.00 | 0.00 |
| December | 174.66 | 460.50 | 269.66 | 163.62 | 106.04 | 0.00 | 0.00 |
| Annual Sum or Average | 399.07 | 234.31 | 393.87 | 199.98 | 193.90 | 0.00 | 0.00 |
| Minimum of Months | 174.66 | 69.27 | 259.36 | 147.30 | 106.04 | 0.00 | 0.00 |
| Maximum of Months | 575.75 | 472.21 | 470.21 | 286.18 | 278.03 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 6.34 | 542.17 | 102.46 | 25.43 | 77.03 | 0.00 | 0.00 |
| February | 45.54 | 421.07 | 159.30 | 40.73 | 118.56 | 0.00 | 0.00 |
| March | 103.56 | 323.57 | 208.37 | 64.79 | 143.58 | 0.00 | 0.00 |
| April | 226.65 | 193.96 | 282.67 | 97.44 | 185.24 | 0.00 | 0.00 |
| May | 347.96 | 108.00 | 339.91 | 93.31 | 246.60 | 0.00 | 0.00 |
| June | 441.86 | 74.88 | 382.00 | 122.83 | 259.17 | 0.00 | 0.00 |
| July | 444.84 | 67.29 | 370.62 | 114.59 | 256.03 | 0.00 | 0.00 |
| August | 319.85 | 82.07 | 283.91 | 74.61 | 209.30 | 0.00 | 0.00 |
| September | 211.42 | 132.97 | 224.96 | 59.65 | 165.31 | 0.00 | 0.00 |
| October | 89.57 | 200.67 | 143.89 | 30.14 | 113.74 | 0.00 | 0.00 |
| November | 23.29 | 320.08 | 93.48 | 17.06 | 76.42 | 0.00 | 0.00 |
| December | 2.62 | 526.95 | 82.44 | 17.56 | 64.88 | 0.00 | 0.00 |
| Annual Sum or Average | 189.39 | 248.82 | 223.10 | 63.24 | 159.86 | 0.00 | 0.00 |
| Minimum of Months | 2.62 | 67.29 | 82.44 | 17.06 | 64.88 | 0.00 | 0.00 |
| Maximum of Months | 444.84 | 542.17 | 382.00 | 122.83 | 259.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.33 | 355.90 | 41.81 | 0.00 | 41.81 | 0.00 | 0.00 |
| February | 5.54 | 279.41 | 64.23 | 0.00 | 64.23 | 0.00 | 0.00 |
| March | 15.95 | 213.49 | 79.04 | 0.01 | 79.04 | 0.00 | 0.00 |
| April | 56.14 | 124.58 | 103.82 | 1.02 | 102.81 | 0.00 | 0.00 |
| May | 134.57 | 66.15 | 145.83 | 7.85 | 137.98 | 0.00 | 0.00 |
| June | 180.36 | 45.28 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
| July | 181.01 | 40.50 | 155.14 | 13.12 | 142.02 | 0.00 | 0.00 |
| August | 124.78 | 49.99 | 118.39 | 2.39 | 116.00 | 0.00 | 0.00 |
| September | 72.43 | 85.34 | 92.02 | 0.07 | 91.96 | 0.00 | 0.00 |
| October | 27.51 | 128.58 | 63.83 | 0.00 | 63.83 | 0.00 | 0.00 |
| November | 4.18 | 206.29 | 42.26 | 0.00 | 42.26 | 0.00 | 0.00 |
| December | 0.00 | 340.99 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Annual Sum or Average | 67.28 | 160.91 | 92.17 | 3.54 | 88.63 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 40.50 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Maximum of Months | 181.01 | 355.90 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.33 | 355.90 | 41.81 | 0.00 | 41.81 | 0.00 | 0.00 |
| February | 5.54 | 279.41 | 64.23 | 0.00 | 64.23 | 0.00 | 0.00 |
| March | 15.94 | 213.48 | 79.04 | 0.01 | 79.04 | 0.00 | 0.00 |
| April | 56.09 | 124.56 | 103.82 | 1.02 | 102.81 | 0.00 | 0.00 |
| May | 134.53 | 66.14 | 145.83 | 7.85 | 137.98 | 0.00 | 0.00 |
| June | 180.34 | 45.27 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
| July | 181.00 | 40.49 | 155.14 | 13.12 | 142.02 | 0.00 | 0.00 |
| August | 124.77 | 49.98 | 118.39 | 2.39 | 116.00 | 0.00 | 0.00 |
| September | 72.40 | 85.33 | 92.02 | 0.07 | 91.96 | 0.00 | 0.00 |
| October | 27.51 | 128.54 | 63.83 | 0.00 | 63.83 | 0.00 | 0.00 |
| November | 4.18 | 206.29 | 42.26 | 0.00 | 42.26 | 0.00 | 0.00 |
| December | 0.00 | 340.99 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Annual Sum or Average | 67.27 | 160.90 | 92.17 | 3.54 | 88.63 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 40.49 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Maximum of Months | 181.00 | 355.90 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 245.55 | 285.63 | 288.25 | 200.38 | 87.87 | 0.00 | 0.00 |
| February | 350.21 | 238.51 | 363.78 | 245.44 | 118.34 | 0.00 | 0.00 |
| March | 313.21 | 195.08 | 317.18 | 199.25 | 117.93 | 0.00 | 0.00 |
| April | 313.06 | 129.72 | 291.36 | 158.27 | 133.09 | 0.00 | 0.00 |
| May | 286.24 | 73.94 | 246.57 | 85.54 | 161.03 | 0.00 | 0.00 |
| June | 271.93 | 49.57 | 220.06 | 59.02 | 161.04 | 0.00 | 0.00 |
| July | 314.00 | 43.78 | 242.90 | 78.88 | 164.02 | 0.00 | 0.00 |
| August | 316.90 | 52.60 | 253.50 | 104.37 | 149.14 | 0.00 | 0.00 |
| September | 313.59 | 86.68 | 271.20 | 142.83 | 128.37 | 0.00 | 0.00 |
| October | 245.19 | 126.37 | 237.46 | 140.86 | 96.60 | 0.00 | 0.00 |
| November | 190.29 | 181.38 | 208.15 | 130.25 | 77.90 | 0.00 | 0.00 |
| December | 175.51 | 276.67 | 222.65 | 146.06 | 76.58 | 0.00 | 0.00 |
| Annual Sum or Average | 277.44 | 144.59 | 262.94 | 140.27 | 122.67 | 0.00 | 0.00 |
| Minimum of Months | 175.51 | 43.78 | 208.15 | 59.02 | 76.58 | 0.00 | 0.00 |
| Maximum of Months | 350.21 | 285.63 | 363.78 | 245.44 | 164.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 245.55 | 285.63 | 288.25 | 200.38 | 87.87 | 0.00 | 0.00 |
| February | 350.21 | 238.50 | 363.78 | 245.44 | 118.34 | 0.00 | 0.00 |
| March | 313.19 | 195.06 | 317.18 | 199.25 | 117.93 | 0.00 | 0.00 |
| April | 313.00 | 129.73 | 291.36 | 158.27 | 133.09 | 0.00 | 0.00 |
| May | 286.21 | 73.92 | 246.57 | 85.54 | 161.03 | 0.00 | 0.00 |
| June | 271.91 | 49.56 | 220.06 | 59.02 | 161.04 | 0.00 | 0.00 |
| July | 313.98 | 43.77 | 242.90 | 78.88 | 164.02 | 0.00 | 0.00 |
| August | 316.89 | 52.59 | 253.50 | 104.37 | 149.14 | 0.00 | 0.00 |
| September | 313.59 | 86.66 | 271.20 | 142.83 | 128.37 | 0.00 | 0.00 |
| October | 245.19 | 126.33 | 237.46 | 140.86 | 96.60 | 0.00 | 0.00 |
| November | 190.28 | 181.38 | 208.15 | 130.25 | 77.90 | 0.00 | 0.00 |
| December | 175.50 | 276.67 | 222.65 | 146.06 | 76.58 | 0.00 | 0.00 |
| Annual Sum or Average | 277.43 | 144.58 | 262.94 | 140.27 | 122.67 | 0.00 | 0.00 |
| Minimum of Months | 175.50 | 43.77 | 208.15 | 59.02 | 76.58 | 0.00 | 0.00 |
| Maximum of Months | 350.21 | 285.63 | 363.78 | 245.44 | 164.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 252.23 | 463.38 | 349.84 | 226.35 | 123.49 | 0.00 | 0.00 |
| February | 404.57 | 384.26 | 463.36 | 290.95 | 172.41 | 0.00 | 0.00 |
| March | 411.55 | 309.37 | 448.20 | 266.41 | 181.79 | 0.00 | 0.00 |
| April | 471.96 | 196.58 | 458.32 | 242.82 | 215.50 | 0.00 | 0.00 |
| May | 518.48 | 109.60 | 452.16 | 183.76 | 268.40 | 0.00 | 0.00 |
| June | 506.34 | 74.17 | 418.13 | 144.71 | 273.43 | 0.00 | 0.00 |
| July | 571.34 | 68.51 | 454.76 | 177.62 | 277.14 | 0.00 | 0.00 |
| August | 522.26 | 81.11 | 427.01 | 182.94 | 244.07 | 0.00 | 0.00 |
| September | 461.39 | 126.23 | 407.11 | 203.78 | 203.33 | 0.00 | 0.00 |
| October | 318.91 | 192.83 | 323.46 | 175.41 | 148.05 | 0.00 | 0.00 |
| November | 213.19 | 290.80 | 260.61 | 148.12 | 112.49 | 0.00 | 0.00 |
| December | 172.98 | 450.41 | 268.98 | 162.18 | 106.80 | 0.00 | 0.00 |
| Annual Sum or Average | 401.96 | 228.29 | 393.85 | 199.85 | 194.00 | 0.00 | 0.00 |
| Minimum of Months | 172.98 | 68.51 | 260.61 | 144.71 | 106.80 | 0.00 | 0.00 |
| Maximum of Months | 571.34 | 463.38 | 463.36 | 290.95 | 277.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 11.71 | 535.95 | 103.40 | 25.97 | 77.44 | 0.00 | 0.00 |
| February | 60.64 | 421.40 | 163.81 | 45.51 | 118.30 | 0.00 | 0.00 |
| March | 115.83 | 324.71 | 210.07 | 67.16 | 142.90 | 0.00 | 0.00 |
| April | 219.37 | 194.42 | 270.79 | 85.57 | 185.22 | 0.00 | 0.00 |
| May | 369.76 | 102.68 | 351.43 | 106.08 | 245.35 | 0.00 | 0.00 |
| June | 416.29 | 70.57 | 360.62 | 103.48 | 257.14 | 0.00 | 0.00 |
| July | 439.66 | 65.32 | 367.00 | 111.86 | 255.14 | 0.00 | 0.00 |
| August | 332.89 | 78.47 | 291.90 | 80.97 | 210.94 | 0.00 | 0.00 |
| September | 224.53 | 123.44 | 227.94 | 61.01 | 166.92 | 0.00 | 0.00 |
| October | 102.87 | 195.62 | 149.83 | 34.55 | 115.28 | 0.00 | 0.00 |
| November | 27.24 | 313.59 | 94.73 | 17.88 | 76.85 | 0.00 | 0.00 |
| December | 3.91 | 519.46 | 81.76 | 16.12 | 65.65 | 0.00 | 0.00 |
| Annual Sum or Average | 194.51 | 244.79 | 223.08 | 63.11 | 159.97 | 0.00 | 0.00 |
| Minimum of Months | 3.91 | 65.32 | 81.76 | 16.12 | 65.65 | 0.00 | 0.00 |
| Maximum of Months | 439.66 | 535.95 | 367.00 | 111.86 | 257.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 251.40 | 460.87 | 348.89 | 225.81 | 123.08 | 0.00 | 0.00 |
| February | 397.81 | 380.27 | 458.85 | 286.18 | 172.67 | 0.00 | 0.00 |
| March | 405.32 | 304.44 | 446.51 | 264.04 | 182.47 | 0.00 | 0.00 |
| April | 481.65 | 190.96 | 470.21 | 254.69 | 215.52 | 0.00 | 0.00 |
| May | 497.38 | 104.56 | 440.64 | 170.99 | 269.65 | 0.00 | 0.00 |
| June | 530.56 | 72.20 | 439.52 | 164.06 | 275.46 | 0.00 | 0.00 |
| July | 573.09 | 65.94 | 458.38 | 180.35 | 278.03 | 0.00 | 0.00 |
| August | 509.01 | 78.84 | 419.02 | 176.58 | 242.44 | 0.00 | 0.00 |
| September | 455.15 | 123.52 | 404.14 | 202.42 | 201.72 | 0.00 | 0.00 |
| October | 310.34 | 191.20 | 317.52 | 171.00 | 146.52 | 0.00 | 0.00 |
| November | 211.29 | 288.60 | 259.36 | 147.30 | 112.05 | 0.00 | 0.00 |
| December | 175.77 | 449.20 | 269.66 | 163.62 | 106.04 | 0.00 | 0.00 |
| Annual Sum or Average | 399.70 | 225.24 | 393.87 | 199.98 | 193.90 | 0.00 | 0.00 |
| Minimum of Months | 175.77 | 65.94 | 259.36 | 147.30 | 106.04 | 0.00 | 0.00 |
| Maximum of Months | 573.09 | 460.87 | 470.21 | 286.18 | 278.03 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 6.90 | 529.53 | 102.46 | 25.43 | 77.03 | 0.00 | 0.00 |
| February | 46.90 | 410.70 | 159.30 | 40.73 | 118.56 | 0.00 | 0.00 |
| March | 104.85 | 314.77 | 208.37 | 64.79 | 143.58 | 0.00 | 0.00 |
| April | 227.51 | 186.69 | 282.67 | 97.44 | 185.24 | 0.00 | 0.00 |
| May | 351.09 | 100.30 | 339.91 | 93.31 | 246.60 | 0.00 | 0.00 |
| June | 441.59 | 69.70 | 382.00 | 122.83 | 259.17 | 0.00 | 0.00 |
| July | 442.96 | 64.19 | 370.62 | 114.59 | 256.03 | 0.00 | 0.00 |
| August | 320.12 | 76.87 | 283.91 | 74.61 | 209.30 | 0.00 | 0.00 |
| September | 217.07 | 120.13 | 224.96 | 59.65 | 165.31 | 0.00 | 0.00 |
| October | 91.96 | 191.41 | 143.89 | 30.14 | 113.74 | 0.00 | 0.00 |
| November | 24.26 | 310.36 | 93.48 | 17.06 | 76.42 | 0.00 | 0.00 |
| December | 2.89 | 514.46 | 82.44 | 17.56 | 64.88 | 0.00 | 0.00 |
| Annual Sum or Average | 190.60 | 240.12 | 223.10 | 63.24 | 159.86 | 0.00 | 0.00 |
| Minimum of Months | 2.89 | 64.19 | 82.44 | 17.06 | 64.88 | 0.00 | 0.00 |
| Maximum of Months | 442.96 | 529.53 | 382.00 | 122.83 | 259.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.37 | 348.88 | 41.81 | 0.00 | 41.81 | 0.00 | 0.00 |
| February | 5.86 | 273.29 | 64.23 | 0.00 | 64.23 | 0.00 | 0.00 |
| March | 16.44 | 208.27 | 79.04 | 0.01 | 79.04 | 0.00 | 0.00 |
| April | 56.97 | 120.31 | 103.82 | 1.02 | 102.81 | 0.00 | 0.00 |
| May | 137.26 | 62.10 | 145.83 | 7.85 | 137.98 | 0.00 | 0.00 |
| June | 180.88 | 43.07 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
| July | 180.29 | 39.35 | 155.14 | 13.12 | 142.02 | 0.00 | 0.00 |
| August | 125.19 | 47.82 | 118.39 | 2.39 | 116.00 | 0.00 | 0.00 |
| September | 76.58 | 76.87 | 92.02 | 0.07 | 91.96 | 0.00 | 0.00 |
| October | 29.16 | 122.31 | 63.83 | 0.00 | 63.83 | 0.00 | 0.00 |
| November | 4.51 | 200.44 | 42.26 | 0.00 | 42.26 | 0.00 | 0.00 |
| December | 0.00 | 334.19 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Annual Sum or Average | 68.17 | 155.95 | 92.17 | 3.54 | 88.63 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 39.35 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Maximum of Months | 180.88 | 348.88 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 0.37 | 348.88 | 41.81 | 0.00 | 41.81 | 0.00 | 0.00 |
| February | 5.85 | 273.28 | 64.23 | 0.00 | 64.23 | 0.00 | 0.00 |
| March | 16.42 | 208.23 | 79.04 | 0.01 | 79.04 | 0.00 | 0.00 |
| April | 56.85 | 120.26 | 103.82 | 1.02 | 102.81 | 0.00 | 0.00 |
| May | 137.14 | 62.05 | 145.83 | 7.85 | 137.98 | 0.00 | 0.00 |
| June | 180.77 | 43.05 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
| July | 180.25 | 39.31 | 155.14 | 13.12 | 142.02 | 0.00 | 0.00 |
| August | 125.15 | 47.79 | 118.39 | 2.39 | 116.00 | 0.00 | 0.00 |
| September | 76.45 | 76.83 | 92.02 | 0.07 | 91.96 | 0.00 | 0.00 |
| October | 29.12 | 122.26 | 63.83 | 0.00 | 63.83 | 0.00 | 0.00 |
| November | 4.50 | 200.43 | 42.26 | 0.00 | 42.26 | 0.00 | 0.00 |
| December | 0.00 | 334.19 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Annual Sum or Average | 68.12 | 155.92 | 92.17 | 3.54 | 88.63 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 39.31 | 35.43 | 0.00 | 35.43 | 0.00 | 0.00 |
| Maximum of Months | 180.77 | 348.88 | 162.54 | 17.78 | 144.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 246.38 | 279.36 | 288.25 | 200.38 | 87.87 | 0.00 | 0.00 |
| February | 350.24 | 232.87 | 363.78 | 245.44 | 118.34 | 0.00 | 0.00 |
| March | 312.98 | 189.81 | 317.18 | 199.25 | 117.93 | 0.00 | 0.00 |
| April | 313.79 | 123.47 | 291.36 | 158.27 | 133.09 | 0.00 | 0.00 |
| May | 287.53 | 68.96 | 246.57 | 85.54 | 161.03 | 0.00 | 0.00 |
| June | 271.70 | 46.85 | 220.06 | 59.02 | 161.04 | 0.00 | 0.00 |
| July | 312.56 | 42.28 | 242.90 | 78.88 | 164.02 | 0.00 | 0.00 |
| August | 316.17 | 50.30 | 253.50 | 104.37 | 149.14 | 0.00 | 0.00 |
| September | 316.04 | 78.97 | 271.20 | 142.83 | 128.37 | 0.00 | 0.00 |
| October | 247.25 | 118.38 | 237.46 | 140.86 | 96.60 | 0.00 | 0.00 |
| November | 190.83 | 176.04 | 208.15 | 130.25 | 77.90 | 0.00 | 0.00 |
| December | 176.25 | 270.50 | 222.65 | 146.06 | 76.58 | 0.00 | 0.00 |
| Annual Sum or Average | 277.95 | 139.42 | 262.94 | 140.27 | 122.67 | 0.00 | 0.00 |
| Minimum of Months | 176.25 | 42.28 | 208.15 | 59.02 | 76.58 | 0.00 | 0.00 |
| Maximum of Months | 350.24 | 279.36 | 363.78 | 245.44 | 164.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 246.37 | 279.35 | 288.25 | 200.38 | 87.87 | 0.00 | 0.00 |
| February | 350.22 | 232.83 | 363.78 | 245.44 | 118.34 | 0.00 | 0.00 |
| March | 312.93 | 189.76 | 317.18 | 199.25 | 117.93 | 0.00 | 0.00 |
| April | 313.67 | 123.42 | 291.36 | 158.27 | 133.09 | 0.00 | 0.00 |
| May | 287.45 | 68.89 | 246.57 | 85.54 | 161.03 | 0.00 | 0.00 |
| June | 271.60 | 46.82 | 220.06 | 59.02 | 161.04 | 0.00 | 0.00 |
| July | 312.52 | 42.23 | 242.90 | 78.88 | 164.02 | 0.00 | 0.00 |
| August | 316.13 | 50.26 | 253.50 | 104.37 | 149.14 | 0.00 | 0.00 |
| September | 315.99 | 78.92 | 271.20 | 142.83 | 128.37 | 0.00 | 0.00 |
| October | 247.23 | 118.34 | 237.46 | 140.86 | 96.60 | 0.00 | 0.00 |
| November | 190.81 | 176.03 | 208.15 | 130.25 | 77.90 | 0.00 | 0.00 |
| December | 176.24 | 270.50 | 222.65 | 146.06 | 76.58 | 0.00 | 0.00 |
| Annual Sum or Average | 277.90 | 139.38 | 262.94 | 140.27 | 122.67 | 0.00 | 0.00 |
| Minimum of Months | 176.24 | 42.23 | 208.15 | 59.02 | 76.58 | 0.00 | 0.00 |
| Maximum of Months | 350.22 | 279.35 | 363.78 | 245.44 | 164.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 5.90 | 49.30 | 14.55 | 6.10 | 8.45 | 0.00 | 0.00 |
| February | 13.93 | 39.03 | 22.81 | 9.77 | 13.04 | 0.00 | 0.00 |
| March | 24.21 | 30.76 | 31.03 | 15.54 | 15.49 | 0.00 | 0.00 |
| April | 42.09 | 19.17 | 42.92 | 23.14 | 19.78 | 0.00 | 0.00 |
| May | 51.04 | 11.08 | 46.57 | 20.50 | 26.06 | 0.00 | 0.00 |
| June | 62.12 | 7.96 | 52.66 | 25.21 | 27.45 | 0.00 | 0.00 |
| July | 62.40 | 7.31 | 51.71 | 24.35 | 27.36 | 0.00 | 0.00 |
| August | 46.09 | 8.70 | 39.72 | 17.33 | 22.39 | 0.00 | 0.00 |
| September | 33.64 | 13.03 | 31.90 | 14.30 | 17.60 | 0.00 | 0.00 |
| October | 15.37 | 19.52 | 19.21 | 7.23 | 11.98 | 0.00 | 0.00 |
| November | 6.11 | 29.85 | 12.29 | 4.09 | 8.20 | 0.00 | 0.00 |
| December | 3.66 | 47.85 | 11.28 | 4.21 | 7.07 | 0.00 | 0.00 |
| Annual Sum or Average | 30.62 | 23.57 | 31.42 | 14.33 | 17.09 | 0.00 | 0.00 |
| Minimum of Months | 3.66 | 7.31 | 11.28 | 4.09 | 7.07 | 0.00 | 0.00 |
| Maximum of Months | 62.40 | 49.30 | 52.66 | 25.21 | 27.45 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.38 | 127.22 | 43.34 | 18.17 | 25.17 | 0.00 | 0.00 |
| February | 46.26 | 101.50 | 67.94 | 29.11 | 38.83 | 0.00 | 0.00 |
| March | 77.63 | 79.27 | 92.42 | 46.30 | 46.12 | 0.00 | 0.00 |
| April | 131.68 | 50.36 | 127.81 | 68.90 | 58.91 | 0.00 | 0.00 |
| May | 157.05 | 29.85 | 138.69 | 61.07 | 77.62 | 0.00 | 0.00 |
| June | 187.56 | 22.78 | 156.84 | 75.07 | 81.77 | 0.00 | 0.00 |
| July | 186.60 | 22.09 | 153.99 | 72.52 | 81.48 | 0.00 | 0.00 |
| August | 138.15 | 26.19 | 118.28 | 51.61 | 66.68 | 0.00 | 0.00 |
| September | 100.62 | 39.08 | 95.00 | 42.58 | 52.42 | 0.00 | 0.00 |
| October | 47.72 | 54.68 | 57.21 | 21.54 | 35.67 | 0.00 | 0.00 |
| November | 20.30 | 79.27 | 36.60 | 12.19 | 24.41 | 0.00 | 0.00 |
| December | 12.78 | 123.98 | 33.60 | 12.55 | 21.05 | 0.00 | 0.00 |
| Annual Sum or Average | 94.11 | 62.87 | 93.57 | 42.67 | 50.90 | 0.00 | 0.00 |
| Minimum of Months | 12.78 | 22.09 | 33.60 | 12.19 | 21.05 | 0.00 | 0.00 |
| Maximum of Months | 187.56 | 127.22 | 156.84 | 75.07 | 81.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 5.57 | 52.07 | 14.55 | 6.10 | 8.45 | 0.00 | 0.00 |
| February | 13.42 | 41.24 | 22.81 | 9.77 | 13.04 | 0.00 | 0.00 |
| March | 23.67 | 32.51 | 31.03 | 15.54 | 15.49 | 0.00 | 0.00 |
| April | 41.42 | 20.36 | 42.92 | 23.14 | 19.78 | 0.00 | 0.00 |
| May | 50.31 | 11.76 | 46.57 | 20.50 | 26.06 | 0.00 | 0.00 |
| June | 61.83 | 8.36 | 52.66 | 25.21 | 27.45 | 0.00 | 0.00 |
| July | 62.35 | 7.53 | 51.71 | 24.35 | 27.36 | 0.00 | 0.00 |
| August | 45.86 | 9.11 | 39.72 | 17.33 | 22.39 | 0.00 | 0.00 |
| September | 32.71 | 14.30 | 31.90 | 14.30 | 17.60 | 0.00 | 0.00 |
| October | 14.71 | 21.08 | 19.21 | 7.23 | 11.98 | 0.00 | 0.00 |
| November | 5.80 | 31.80 | 12.29 | 4.09 | 8.20 | 0.00 | 0.00 |
| December | 3.45 | 50.61 | 11.28 | 4.21 | 7.07 | 0.00 | 0.00 |
| Annual Sum or Average | 30.17 | 25.00 | 31.42 | 14.33 | 17.09 | 0.00 | 0.00 |
| Minimum of Months | 3.45 | 7.53 | 11.28 | 4.09 | 7.07 | 0.00 | 0.00 |
| Maximum of Months | 62.35 | 52.07 | 52.66 | 25.21 | 27.45 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.686648E+09 | 0.123719E+10 | 0.937004E+09 | 0.606258E+09 | 0.330746E+09 | 0.00 | 0.00 |
| February | 0.997889E+09 | 0.923962E+09 | 0.112095E+10 | 0.703866E+09 | 0.417084E+09 | 0.00 | 0.00 |
| March | 0.112921E+10 | 0.815500E+09 | 0.120047E+10 | 0.713556E+09 | 0.486913E+09 | 0.00 | 0.00 |
| April | 0.126022E+10 | 0.494156E+09 | 0.118797E+10 | 0.629391E+09 | 0.558576E+09 | 0.00 | 0.00 |
| May | 0.142275E+10 | 0.284024E+09 | 0.121107E+10 | 0.492189E+09 | 0.718881E+09 | 0.00 | 0.00 |
| June | 0.133596E+10 | 0.191730E+09 | 0.108381E+10 | 0.375086E+09 | 0.708719E+09 | 0.00 | 0.00 |
| July | 0.154587E+10 | 0.189256E+09 | 0.121804E+10 | 0.475744E+09 | 0.742294E+09 | 0.00 | 0.00 |
| August | 0.140801E+10 | 0.228451E+09 | 0.114371E+10 | 0.489986E+09 | 0.653729E+09 | 0.00 | 0.00 |
| September | 0.119469E+10 | 0.354619E+09 | 0.105523E+10 | 0.528192E+09 | 0.527038E+09 | 0.00 | 0.00 |
| October | 0.858680E+09 | 0.534294E+09 | 0.866354E+09 | 0.469820E+09 | 0.396535E+09 | 0.00 | 0.00 |
| November | 0.560393E+09 | 0.757444E+09 | 0.675507E+09 | 0.383937E+09 | 0.291570E+09 | 0.00 | 0.00 |
| December | 0.470623E+09 | 0.120400E+10 | 0.720438E+09 | 0.434385E+09 | 0.286053E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.128710E+11 | 0.721462E+10 | 0.124205E+11 | 0.630241E+10 | 0.611814E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.470623E+09 | 0.189256E+09 | 0.675507E+09 | 0.375086E+09 | 0.286053E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.154587E+10 | 0.123719E+10 | 0.121804E+10 | 0.713556E+09 | 0.742294E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 33170354.25 | 0.142510E+10 | 0.276953E+09 | 69549419.71 | 0.207404E+09 | 0.00 | 0.00 |
| February | 0.153159E+09 | 0.100952E+10 | 0.396278E+09 | 0.110089E+09 | 0.286188E+09 | 0.00 | 0.00 |
| March | 0.323313E+09 | 0.854013E+09 | 0.562638E+09 | 0.179891E+09 | 0.382747E+09 | 0.00 | 0.00 |
| April | 0.597737E+09 | 0.485171E+09 | 0.701877E+09 | 0.221788E+09 | 0.480089E+09 | 0.00 | 0.00 |
| May | 0.102738E+10 | 0.259327E+09 | 0.941259E+09 | 0.284125E+09 | 0.657134E+09 | 0.00 | 0.00 |
| June | 0.110329E+10 | 0.179397E+09 | 0.934724E+09 | 0.268214E+09 | 0.666510E+09 | 0.00 | 0.00 |
| July | 0.119067E+10 | 0.178137E+09 | 0.982981E+09 | 0.299601E+09 | 0.683380E+09 | 0.00 | 0.00 |
| August | 0.896607E+09 | 0.218979E+09 | 0.781835E+09 | 0.216861E+09 | 0.564974E+09 | 0.00 | 0.00 |
| September | 0.577310E+09 | 0.340588E+09 | 0.590808E+09 | 0.158150E+09 | 0.432658E+09 | 0.00 | 0.00 |
| October | 0.279247E+09 | 0.530079E+09 | 0.401300E+09 | 92544862.74 | 0.308755E+09 | 0.00 | 0.00 |
| November | 72661421.50 | 0.813710E+09 | 0.245540E+09 | 46332842.64 | 0.199207E+09 | 0.00 | 0.00 |
| December | 11172303.42 | 0.138376E+10 | 0.218997E+09 | 43172232.58 | 0.175824E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.626571E+10 | 0.767779E+10 | 0.703519E+10 | 0.199032E+10 | 0.504487E+10 | 0.00 | 0.00 |
| Minimum of Months | 11172303.42 | 0.178137E+09 | 0.218997E+09 | 43172232.58 | 0.175824E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.119067E+10 | 0.142510E+10 | 0.982981E+09 | 0.299601E+09 | 0.683380E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.718931E+09 | 0.109878E+10 | 0.934467E+09 | 0.604807E+09 | 0.329660E+09 | 0.00 | 0.00 |
| February | 0.101810E+10 | 0.814338E+09 | 0.111004E+10 | 0.692323E+09 | 0.417720E+09 | 0.00 | 0.00 |
| March | 0.114976E+10 | 0.709031E+09 | 0.119592E+10 | 0.707195E+09 | 0.488728E+09 | 0.00 | 0.00 |
| April | 0.130864E+10 | 0.442338E+09 | 0.121878E+10 | 0.660156E+09 | 0.558623E+09 | 0.00 | 0.00 |
| May | 0.135810E+10 | 0.284848E+09 | 0.118022E+10 | 0.457973E+09 | 0.722244E+09 | 0.00 | 0.00 |
| June | 0.137567E+10 | 0.214936E+09 | 0.113922E+10 | 0.425242E+09 | 0.713982E+09 | 0.00 | 0.00 |
| July | 0.150923E+10 | 0.226652E+09 | 0.122773E+10 | 0.483055E+09 | 0.744670E+09 | 0.00 | 0.00 |
| August | 0.134504E+10 | 0.269808E+09 | 0.112230E+10 | 0.472956E+09 | 0.649345E+09 | 0.00 | 0.00 |
| September | 0.116313E+10 | 0.379372E+09 | 0.104752E+10 | 0.524665E+09 | 0.522859E+09 | 0.00 | 0.00 |
| October | 0.842314E+09 | 0.522601E+09 | 0.850444E+09 | 0.458009E+09 | 0.392435E+09 | 0.00 | 0.00 |
| November | 0.581562E+09 | 0.666744E+09 | 0.672256E+09 | 0.381814E+09 | 0.290443E+09 | 0.00 | 0.00 |
| December | 0.506479E+09 | 0.106884E+10 | 0.722255E+09 | 0.438240E+09 | 0.284015E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.128770E+11 | 0.669829E+10 | 0.124212E+11 | 0.630643E+10 | 0.611472E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.506479E+09 | 0.214936E+09 | 0.672256E+09 | 0.381814E+09 | 0.284015E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.150923E+10 | 0.109878E+10 | 0.122773E+10 | 0.707195E+09 | 0.744670E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 19686282.56 | 0.140855E+10 | 0.274416E+09 | 68098831.84 | 0.206317E+09 | 0.00 | 0.00 |
| February | 0.118522E+09 | 0.983463E+09 | 0.385370E+09 | 98545815.50 | 0.286824E+09 | 0.00 | 0.00 |
| March | 0.292648E+09 | 0.827378E+09 | 0.558092E+09 | 0.173530E+09 | 0.384562E+09 | 0.00 | 0.00 |
| April | 0.620113E+09 | 0.465438E+09 | 0.732690E+09 | 0.252554E+09 | 0.480136E+09 | 0.00 | 0.00 |
| May | 0.982683E+09 | 0.253306E+09 | 0.910405E+09 | 0.249908E+09 | 0.660497E+09 | 0.00 | 0.00 |
| June | 0.116993E+10 | 0.179106E+09 | 0.990143E+09 | 0.318371E+09 | 0.671772E+09 | 0.00 | 0.00 |
| July | 0.120081E+10 | 0.175910E+09 | 0.992669E+09 | 0.306912E+09 | 0.685756E+09 | 0.00 | 0.00 |
| August | 0.863641E+09 | 0.215264E+09 | 0.760421E+09 | 0.199831E+09 | 0.560590E+09 | 0.00 | 0.00 |
| September | 0.558670E+09 | 0.331360E+09 | 0.583101E+09 | 0.154623E+09 | 0.428478E+09 | 0.00 | 0.00 |
| October | 0.249449E+09 | 0.518746E+09 | 0.385389E+09 | 80734764.76 | 0.304655E+09 | 0.00 | 0.00 |
| November | 64319507.93 | 0.805604E+09 | 0.242289E+09 | 44208928.19 | 0.198080E+09 | 0.00 | 0.00 |
| December | 8192942.30 | 0.137151E+10 | 0.220814E+09 | 47027250.96 | 0.173787E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.614867E+10 | 0.753564E+10 | 0.703580E+10 | 0.199434E+10 | 0.504146E+10 | 0.00 | 0.00 |
| Minimum of Months | 8192942.30 | 0.175910E+09 | 0.220814E+09 | 44208928.19 | 0.173787E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.120081E+10 | 0.140855E+10 | 0.992669E+09 | 0.318371E+09 | 0.685756E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 1190056.85 | 0.927401E+09 | 0.111995E+09 | 0.00 | 0.111995E+09 | 0.00 | 0.00 |
| February | 15472435.91 | 0.653911E+09 | 0.155385E+09 | 0.00 | 0.155385E+09 | 0.00 | 0.00 |
| March | 47843363.89 | 0.547618E+09 | 0.211714E+09 | 15171.03 | 0.211698E+09 | 0.00 | 0.00 |
| April | 0.159995E+09 | 0.300620E+09 | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.00 | 0.00 |
| May | 0.386809E+09 | 0.156827E+09 | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.00 | 0.00 |
| June | 0.479379E+09 | 0.110125E+09 | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.00 | 0.00 |
| July | 0.488692E+09 | 0.106473E+09 | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.00 | 0.00 |
| August | 0.337207E+09 | 0.131544E+09 | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.00 | 0.00 |
| September | 0.193225E+09 | 0.212180E+09 | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.00 | 0.00 |
| October | 78724486.38 | 0.330995E+09 | 0.170963E+09 | 0.00 | 0.170963E+09 | 0.00 | 0.00 |
| November | 12109281.33 | 0.518993E+09 | 0.109547E+09 | 0.00 | 0.109547E+09 | 0.00 | 0.00 |
| December | 26039.98 | 0.889549E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220067E+10 | 0.488624E+10 | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.00 | 0.00 |
| Minimum of Months | 26039.98 | 0.106473E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Maximum of Months | 0.488692E+09 | 0.927401E+09 | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 1189965.41 | 0.927404E+09 | 0.111995E+09 | 0.00 | 0.111995E+09 | 0.00 | 0.00 |
| February | 15468275.05 | 0.653902E+09 | 0.155385E+09 | 0.00 | 0.155385E+09 | 0.00 | 0.00 |
| March | 47829387.54 | 0.547603E+09 | 0.211714E+09 | 15171.03 | 0.211698E+09 | 0.00 | 0.00 |
| April | 0.159959E+09 | 0.300586E+09 | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.00 | 0.00 |
| May | 0.386859E+09 | 0.156710E+09 | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.00 | 0.00 |
| June | 0.479115E+09 | 0.110231E+09 | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.00 | 0.00 |
| July | 0.488679E+09 | 0.106438E+09 | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.00 | 0.00 |
| August | 0.337176E+09 | 0.131525E+09 | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.00 | 0.00 |
| September | 0.193149E+09 | 0.212179E+09 | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.00 | 0.00 |
| October | 78724618.50 | 0.330922E+09 | 0.170963E+09 | 0.00 | 0.170963E+09 | 0.00 | 0.00 |
| November | 12106098.81 | 0.518996E+09 | 0.109547E+09 | 0.00 | 0.109547E+09 | 0.00 | 0.00 |
| December | 26033.63 | 0.889554E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220028E+10 | 0.488605E+10 | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.00 | 0.00 |
| Minimum of Months | 26033.63 | 0.106438E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Maximum of Months | 0.488679E+09 | 0.927404E+09 | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.666833E+09 | 0.745865E+09 | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.00 | 0.00 |
| February | 0.858672E+09 | 0.560044E+09 | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.00 | 0.00 |
| March | 0.852518E+09 | 0.500839E+09 | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.00 | 0.00 |
| April | 0.831440E+09 | 0.309663E+09 | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.00 | 0.00 |
| May | 0.786381E+09 | 0.178102E+09 | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.00 | 0.00 |
| June | 0.714276E+09 | 0.121425E+09 | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.00 | 0.00 |
| July | 0.844777E+09 | 0.115714E+09 | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.00 | 0.00 |
| August | 0.852003E+09 | 0.139522E+09 | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.00 | 0.00 |
| September | 0.817503E+09 | 0.220391E+09 | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.00 | 0.00 |
| October | 0.663550E+09 | 0.328681E+09 | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.00 | 0.00 |
| November | 0.499692E+09 | 0.457918E+09 | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.00 | 0.00 |
| December | 0.476918E+09 | 0.722750E+09 | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.886456E+10 | 0.440091E+10 | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.476918E+09 | 0.115714E+09 | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.858672E+09 | 0.745865E+09 | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.667797E+09 | 0.743060E+09 | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.00 | 0.00 |
| February | 0.859757E+09 | 0.557664E+09 | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.00 | 0.00 |
| March | 0.853549E+09 | 0.498427E+09 | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.00 | 0.00 |
| April | 0.832053E+09 | 0.308443E+09 | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.00 | 0.00 |
| May | 0.785703E+09 | 0.178530E+09 | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.00 | 0.00 |
| June | 0.712931E+09 | 0.122470E+09 | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.00 | 0.00 |
| July | 0.843524E+09 | 0.116743E+09 | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.00 | 0.00 |
| August | 0.850981E+09 | 0.140615E+09 | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.00 | 0.00 |
| September | 0.816628E+09 | 0.221548E+09 | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.00 | 0.00 |
| October | 0.663490E+09 | 0.328630E+09 | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.00 | 0.00 |
| November | 0.500542E+09 | 0.455526E+09 | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.00 | 0.00 |
| December | 0.477712E+09 | 0.719952E+09 | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.886467E+10 | 0.439161E+10 | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.477712E+09 | 0.116743E+09 | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.859757E+09 | 0.743060E+09 | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.672414E+09 | 0.127143E+10 | 0.937004E+09 | 0.606258E+09 | 0.330746E+09 | 0.00 | 0.00 |
| February | 0.978850E+09 | 0.953989E+09 | 0.112095E+10 | 0.703866E+09 | 0.417084E+09 | 0.00 | 0.00 |
| March | 0.110417E+10 | 0.853845E+09 | 0.120047E+10 | 0.713556E+09 | 0.486913E+09 | 0.00 | 0.00 |
| April | 0.122247E+10 | 0.536605E+09 | 0.118797E+10 | 0.629391E+09 | 0.558576E+09 | 0.00 | 0.00 |
| May | 0.138378E+10 | 0.317897E+09 | 0.121107E+10 | 0.492189E+09 | 0.718881E+09 | 0.00 | 0.00 |
| June | 0.131292E+10 | 0.207417E+09 | 0.108381E+10 | 0.375086E+09 | 0.708719E+09 | 0.00 | 0.00 |
| July | 0.153712E+10 | 0.192813E+09 | 0.121804E+10 | 0.475744E+09 | 0.742294E+09 | 0.00 | 0.00 |
| August | 0.140136E+10 | 0.231488E+09 | 0.114371E+10 | 0.489986E+09 | 0.653729E+09 | 0.00 | 0.00 |
| September | 0.118614E+10 | 0.362083E+09 | 0.105523E+10 | 0.528192E+09 | 0.527038E+09 | 0.00 | 0.00 |
| October | 0.847610E+09 | 0.549590E+09 | 0.866354E+09 | 0.469820E+09 | 0.396535E+09 | 0.00 | 0.00 |
| November | 0.550948E+09 | 0.778232E+09 | 0.675507E+09 | 0.383937E+09 | 0.291570E+09 | 0.00 | 0.00 |
| December | 0.460593E+09 | 0.123643E+10 | 0.720438E+09 | 0.434385E+09 | 0.286053E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.126584E+11 | 0.749181E+10 | 0.124205E+11 | 0.630241E+10 | 0.611814E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.460593E+09 | 0.192813E+09 | 0.675507E+09 | 0.375086E+09 | 0.286053E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.153712E+10 | 0.127143E+10 | 0.121804E+10 | 0.713556E+09 | 0.742294E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 30161629.78 | 0.146925E+10 | 0.276953E+09 | 69549419.71 | 0.207404E+09 | 0.00 | 0.00 |
| February | 0.144618E+09 | 0.104527E+10 | 0.396278E+09 | 0.110089E+09 | 0.286188E+09 | 0.00 | 0.00 |
| March | 0.308266E+09 | 0.894186E+09 | 0.562638E+09 | 0.179891E+09 | 0.382747E+09 | 0.00 | 0.00 |
| April | 0.566879E+09 | 0.523754E+09 | 0.701877E+09 | 0.221788E+09 | 0.480089E+09 | 0.00 | 0.00 |
| May | 0.980736E+09 | 0.295717E+09 | 0.941259E+09 | 0.284125E+09 | 0.657134E+09 | 0.00 | 0.00 |
| June | 0.107643E+10 | 0.195648E+09 | 0.934724E+09 | 0.268214E+09 | 0.666510E+09 | 0.00 | 0.00 |
| July | 0.118139E+10 | 0.182400E+09 | 0.982981E+09 | 0.299601E+09 | 0.683380E+09 | 0.00 | 0.00 |
| August | 0.889637E+09 | 0.223782E+09 | 0.781835E+09 | 0.216861E+09 | 0.564974E+09 | 0.00 | 0.00 |
| September | 0.566875E+09 | 0.354444E+09 | 0.590808E+09 | 0.158150E+09 | 0.432658E+09 | 0.00 | 0.00 |
| October | 0.269711E+09 | 0.549337E+09 | 0.401300E+09 | 92544862.74 | 0.308755E+09 | 0.00 | 0.00 |
| November | 68429755.94 | 0.837994E+09 | 0.245540E+09 | 46332842.64 | 0.199207E+09 | 0.00 | 0.00 |
| December | 9837798.07 | 0.142438E+10 | 0.218997E+09 | 43172232.58 | 0.175824E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.609297E+10 | 0.799617E+10 | 0.703519E+10 | 0.199032E+10 | 0.504487E+10 | 0.00 | 0.00 |
| Minimum of Months | 9837798.07 | 0.182400E+09 | 0.218997E+09 | 43172232.58 | 0.175824E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.118139E+10 | 0.146925E+10 | 0.982981E+09 | 0.299601E+09 | 0.683380E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.669734E+09 | 0.126478E+10 | 0.934467E+09 | 0.604807E+09 | 0.329660E+09 | 0.00 | 0.00 |
| February | 0.961982E+09 | 0.944511E+09 | 0.111004E+10 | 0.692323E+09 | 0.417720E+09 | 0.00 | 0.00 |
| March | 0.108718E+10 | 0.840323E+09 | 0.119592E+10 | 0.707195E+09 | 0.488728E+09 | 0.00 | 0.00 |
| April | 0.124656E+10 | 0.520832E+09 | 0.121878E+10 | 0.660156E+09 | 0.558623E+09 | 0.00 | 0.00 |
| May | 0.132622E+10 | 0.302312E+09 | 0.118022E+10 | 0.457973E+09 | 0.722244E+09 | 0.00 | 0.00 |
| June | 0.137721E+10 | 0.201195E+09 | 0.113922E+10 | 0.425242E+09 | 0.713982E+09 | 0.00 | 0.00 |
| July | 0.154208E+10 | 0.185524E+09 | 0.122773E+10 | 0.483055E+09 | 0.744670E+09 | 0.00 | 0.00 |
| August | 0.136613E+10 | 0.225125E+09 | 0.112230E+10 | 0.472956E+09 | 0.649345E+09 | 0.00 | 0.00 |
| September | 0.116979E+10 | 0.353819E+09 | 0.104752E+10 | 0.524665E+09 | 0.522859E+09 | 0.00 | 0.00 |
| October | 0.824766E+09 | 0.544961E+09 | 0.850444E+09 | 0.458009E+09 | 0.392435E+09 | 0.00 | 0.00 |
| November | 0.545690E+09 | 0.772485E+09 | 0.672256E+09 | 0.381814E+09 | 0.290443E+09 | 0.00 | 0.00 |
| December | 0.467816E+09 | 0.123340E+10 | 0.722255E+09 | 0.438240E+09 | 0.284015E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125851E+11 | 0.738927E+10 | 0.124212E+11 | 0.630643E+10 | 0.611472E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.467816E+09 | 0.185524E+09 | 0.672256E+09 | 0.381814E+09 | 0.284015E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.154208E+10 | 0.126478E+10 | 0.122773E+10 | 0.707195E+09 | 0.744670E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 16971263.13 | 0.145216E+10 | 0.274416E+09 | 68098831.84 | 0.206317E+09 | 0.00 | 0.00 |
| February | 0.110168E+09 | 0.101865E+10 | 0.385370E+09 | 98545815.50 | 0.286824E+09 | 0.00 | 0.00 |
| March | 0.277372E+09 | 0.866661E+09 | 0.558092E+09 | 0.173530E+09 | 0.384562E+09 | 0.00 | 0.00 |
| April | 0.587464E+09 | 0.502749E+09 | 0.732690E+09 | 0.252554E+09 | 0.480136E+09 | 0.00 | 0.00 |
| May | 0.931987E+09 | 0.289257E+09 | 0.910405E+09 | 0.249908E+09 | 0.660497E+09 | 0.00 | 0.00 |
| June | 0.114531E+10 | 0.194076E+09 | 0.990143E+09 | 0.318371E+09 | 0.671772E+09 | 0.00 | 0.00 |
| July | 0.119147E+10 | 0.180231E+09 | 0.992669E+09 | 0.306912E+09 | 0.685756E+09 | 0.00 | 0.00 |
| August | 0.856689E+09 | 0.219815E+09 | 0.760421E+09 | 0.199831E+09 | 0.560590E+09 | 0.00 | 0.00 |
| September | 0.548013E+09 | 0.344654E+09 | 0.583101E+09 | 0.154623E+09 | 0.428478E+09 | 0.00 | 0.00 |
| October | 0.239909E+09 | 0.537476E+09 | 0.385389E+09 | 80734764.76 | 0.304655E+09 | 0.00 | 0.00 |
| November | 60375449.06 | 0.829637E+09 | 0.242289E+09 | 44208928.19 | 0.198080E+09 | 0.00 | 0.00 |
| December | 7024516.38 | 0.141137E+10 | 0.220814E+09 | 47027250.96 | 0.173787E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.597275E+10 | 0.784674E+10 | 0.703580E+10 | 0.199434E+10 | 0.504146E+10 | 0.00 | 0.00 |
| Minimum of Months | 7024516.38 | 0.180231E+09 | 0.220814E+09 | 44208928.19 | 0.173787E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.119147E+10 | 0.145216E+10 | 0.992669E+09 | 0.318371E+09 | 0.685756E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 880719.15 | 0.953243E+09 | 0.111995E+09 | 0.00 | 0.111995E+09 | 0.00 | 0.00 |
| February | 13407286.61 | 0.675957E+09 | 0.155385E+09 | 0.00 | 0.155385E+09 | 0.00 | 0.00 |
| March | 42721440.03 | 0.571815E+09 | 0.211714E+09 | 15171.03 | 0.211698E+09 | 0.00 | 0.00 |
| April | 0.145504E+09 | 0.322899E+09 | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.00 | 0.00 |
| May | 0.360435E+09 | 0.177166E+09 | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.00 | 0.00 |
| June | 0.467495E+09 | 0.117358E+09 | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.00 | 0.00 |
| July | 0.484820E+09 | 0.108467E+09 | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.00 | 0.00 |
| August | 0.334208E+09 | 0.133894E+09 | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.00 | 0.00 |
| September | 0.187730E+09 | 0.221204E+09 | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.00 | 0.00 |
| October | 73686204.35 | 0.344391E+09 | 0.170963E+09 | 0.00 | 0.170963E+09 | 0.00 | 0.00 |
| November | 10836062.83 | 0.534711E+09 | 0.109547E+09 | 0.00 | 0.109547E+09 | 0.00 | 0.00 |
| December | 3372.26 | 0.913314E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.212173E+10 | 0.507442E+10 | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.00 | 0.00 |
| Minimum of Months | 3372.26 | 0.108467E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Maximum of Months | 0.484820E+09 | 0.953243E+09 | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 880633.94 | 0.953245E+09 | 0.111995E+09 | 0.00 | 0.111995E+09 | 0.00 | 0.00 |
| February | 13401884.71 | 0.675942E+09 | 0.155385E+09 | 0.00 | 0.155385E+09 | 0.00 | 0.00 |
| March | 42701926.03 | 0.571773E+09 | 0.211714E+09 | 15171.03 | 0.211698E+09 | 0.00 | 0.00 |
| April | 0.145382E+09 | 0.322870E+09 | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.00 | 0.00 |
| May | 0.360327E+09 | 0.177144E+09 | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.00 | 0.00 |
| June | 0.467433E+09 | 0.117347E+09 | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.00 | 0.00 |
| July | 0.484791E+09 | 0.108439E+09 | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.00 | 0.00 |
| August | 0.334180E+09 | 0.133871E+09 | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.00 | 0.00 |
| September | 0.187660E+09 | 0.221167E+09 | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.00 | 0.00 |
| October | 73683215.34 | 0.344272E+09 | 0.170963E+09 | 0.00 | 0.170963E+09 | 0.00 | 0.00 |
| November | 10832120.93 | 0.534716E+09 | 0.109547E+09 | 0.00 | 0.109547E+09 | 0.00 | 0.00 |
| December | 3372.53 | 0.913319E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.212128E+10 | 0.507411E+10 | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.00 | 0.00 |
| Minimum of Months | 3372.53 | 0.108439E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Maximum of Months | 0.484791E+09 | 0.953245E+09 | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.657692E+09 | 0.765037E+09 | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.00 | 0.00 |
| February | 0.847237E+09 | 0.577013E+09 | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.00 | 0.00 |
| March | 0.838895E+09 | 0.522498E+09 | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.00 | 0.00 |
| April | 0.811440E+09 | 0.336230E+09 | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.00 | 0.00 |
| May | 0.766667E+09 | 0.198030E+09 | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.00 | 0.00 |
| June | 0.704846E+09 | 0.128478E+09 | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.00 | 0.00 |
| July | 0.841005E+09 | 0.117271E+09 | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.00 | 0.00 |
| August | 0.848777E+09 | 0.140888E+09 | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.00 | 0.00 |
| September | 0.812835E+09 | 0.224681E+09 | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.00 | 0.00 |
| October | 0.656720E+09 | 0.338460E+09 | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.00 | 0.00 |
| November | 0.493234E+09 | 0.470144E+09 | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.00 | 0.00 |
| December | 0.470074E+09 | 0.741041E+09 | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.874942E+10 | 0.455977E+10 | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.470074E+09 | 0.117271E+09 | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.848777E+09 | 0.765037E+09 | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.657677E+09 | 0.765029E+09 | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.00 | 0.00 |
| February | 0.847216E+09 | 0.576974E+09 | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.00 | 0.00 |
| March | 0.838844E+09 | 0.522437E+09 | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.00 | 0.00 |
| April | 0.811284E+09 | 0.336247E+09 | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.00 | 0.00 |
| May | 0.766595E+09 | 0.197995E+09 | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.00 | 0.00 |
| June | 0.704789E+09 | 0.128465E+09 | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.00 | 0.00 |
| July | 0.840974E+09 | 0.117240E+09 | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.00 | 0.00 |
| August | 0.848755E+09 | 0.140862E+09 | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.00 | 0.00 |
| September | 0.812821E+09 | 0.224625E+09 | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.00 | 0.00 |
| October | 0.656727E+09 | 0.338366E+09 | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.00 | 0.00 |
| November | 0.493215E+09 | 0.470139E+09 | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.00 | 0.00 |
| December | 0.470063E+09 | 0.741037E+09 | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.874896E+10 | 0.455942E+10 | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.470063E+09 | 0.117240E+09 | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.848755E+09 | 0.765029E+09 | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.675585E+09 | 0.124111E+10 | 0.937004E+09 | 0.606258E+09 | 0.330746E+09 | 0.00 | 0.00 |
| February | 0.978742E+09 | 0.929605E+09 | 0.112095E+10 | 0.703866E+09 | 0.417084E+09 | 0.00 | 0.00 |
| March | 0.110230E+10 | 0.828607E+09 | 0.120047E+10 | 0.713556E+09 | 0.486913E+09 | 0.00 | 0.00 |
| April | 0.122331E+10 | 0.509548E+09 | 0.118797E+10 | 0.629391E+09 | 0.558576E+09 | 0.00 | 0.00 |
| May | 0.138869E+10 | 0.293549E+09 | 0.121107E+10 | 0.492189E+09 | 0.718881E+09 | 0.00 | 0.00 |
| June | 0.131242E+10 | 0.192248E+09 | 0.108381E+10 | 0.375086E+09 | 0.708719E+09 | 0.00 | 0.00 |
| July | 0.153027E+10 | 0.183489E+09 | 0.121804E+10 | 0.475744E+09 | 0.742294E+09 | 0.00 | 0.00 |
| August | 0.139883E+10 | 0.217249E+09 | 0.114371E+10 | 0.489986E+09 | 0.653729E+09 | 0.00 | 0.00 |
| September | 0.119592E+10 | 0.327188E+09 | 0.105523E+10 | 0.528192E+09 | 0.527038E+09 | 0.00 | 0.00 |
| October | 0.854169E+09 | 0.516482E+09 | 0.866354E+09 | 0.469820E+09 | 0.396535E+09 | 0.00 | 0.00 |
| November | 0.552578E+09 | 0.753765E+09 | 0.675507E+09 | 0.383937E+09 | 0.291570E+09 | 0.00 | 0.00 |
| December | 0.463302E+09 | 0.120639E+10 | 0.720438E+09 | 0.434385E+09 | 0.286053E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.126761E+11 | 0.719922E+10 | 0.124205E+11 | 0.630241E+10 | 0.611814E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.463302E+09 | 0.183489E+09 | 0.675507E+09 | 0.375086E+09 | 0.286053E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.153027E+10 | 0.124111E+10 | 0.121804E+10 | 0.713556E+09 | 0.742294E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 31361090.81 | 0.143549E+10 | 0.276953E+09 | 69549419.71 | 0.207404E+09 | 0.00 | 0.00 |
| February | 0.146697E+09 | 0.101945E+10 | 0.396278E+09 | 0.110089E+09 | 0.286188E+09 | 0.00 | 0.00 |
| March | 0.310237E+09 | 0.869713E+09 | 0.562638E+09 | 0.179891E+09 | 0.382747E+09 | 0.00 | 0.00 |
| April | 0.568607E+09 | 0.503944E+09 | 0.701877E+09 | 0.221788E+09 | 0.480089E+09 | 0.00 | 0.00 |
| May | 0.990355E+09 | 0.275027E+09 | 0.941259E+09 | 0.284125E+09 | 0.657134E+09 | 0.00 | 0.00 |
| June | 0.107902E+10 | 0.182911E+09 | 0.934724E+09 | 0.268214E+09 | 0.666510E+09 | 0.00 | 0.00 |
| July | 0.117760E+10 | 0.174950E+09 | 0.982981E+09 | 0.299601E+09 | 0.683380E+09 | 0.00 | 0.00 |
| August | 0.891613E+09 | 0.210179E+09 | 0.781835E+09 | 0.216861E+09 | 0.564974E+09 | 0.00 | 0.00 |
| September | 0.581981E+09 | 0.319945E+09 | 0.590808E+09 | 0.158150E+09 | 0.432658E+09 | 0.00 | 0.00 |
| October | 0.275519E+09 | 0.523942E+09 | 0.401300E+09 | 92544862.74 | 0.308755E+09 | 0.00 | 0.00 |
| November | 70615090.69 | 0.812830E+09 | 0.245540E+09 | 46332842.64 | 0.199207E+09 | 0.00 | 0.00 |
| December | 10471870.11 | 0.139132E+10 | 0.218997E+09 | 43172232.58 | 0.175824E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.613407E+10 | 0.771970E+10 | 0.703519E+10 | 0.199032E+10 | 0.504487E+10 | 0.00 | 0.00 |
| Minimum of Months | 10471870.11 | 0.174950E+09 | 0.218997E+09 | 43172232.58 | 0.175824E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.117760E+10 | 0.143549E+10 | 0.982981E+09 | 0.299601E+09 | 0.683380E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.673336E+09 | 0.123441E+10 | 0.934467E+09 | 0.604807E+09 | 0.329660E+09 | 0.00 | 0.00 |
| February | 0.962380E+09 | 0.919954E+09 | 0.111004E+10 | 0.692323E+09 | 0.417720E+09 | 0.00 | 0.00 |
| March | 0.108561E+10 | 0.815418E+09 | 0.119592E+10 | 0.707195E+09 | 0.488728E+09 | 0.00 | 0.00 |
| April | 0.124843E+10 | 0.494957E+09 | 0.121878E+10 | 0.660156E+09 | 0.558623E+09 | 0.00 | 0.00 |
| May | 0.133219E+10 | 0.280044E+09 | 0.118022E+10 | 0.457973E+09 | 0.722244E+09 | 0.00 | 0.00 |
| June | 0.137521E+10 | 0.187132E+09 | 0.113922E+10 | 0.425242E+09 | 0.713982E+09 | 0.00 | 0.00 |
| July | 0.153496E+10 | 0.176617E+09 | 0.122773E+10 | 0.483055E+09 | 0.744670E+09 | 0.00 | 0.00 |
| August | 0.136332E+10 | 0.211175E+09 | 0.112230E+10 | 0.472956E+09 | 0.649345E+09 | 0.00 | 0.00 |
| September | 0.117975E+10 | 0.320174E+09 | 0.104752E+10 | 0.524665E+09 | 0.522859E+09 | 0.00 | 0.00 |
| October | 0.831217E+09 | 0.512104E+09 | 0.850444E+09 | 0.458009E+09 | 0.392435E+09 | 0.00 | 0.00 |
| November | 0.547668E+09 | 0.748060E+09 | 0.672256E+09 | 0.381814E+09 | 0.290443E+09 | 0.00 | 0.00 |
| December | 0.470774E+09 | 0.120314E+10 | 0.722255E+09 | 0.438240E+09 | 0.284015E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.126049E+11 | 0.710318E+10 | 0.124212E+11 | 0.630643E+10 | 0.611472E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.470774E+09 | 0.176617E+09 | 0.672256E+09 | 0.381814E+09 | 0.284015E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.153496E+10 | 0.123441E+10 | 0.122773E+10 | 0.707195E+09 | 0.744670E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 18478329.90 | 0.141828E+10 | 0.274416E+09 | 68098831.84 | 0.206317E+09 | 0.00 | 0.00 |
| February | 0.113459E+09 | 0.993568E+09 | 0.385370E+09 | 98545815.50 | 0.286824E+09 | 0.00 | 0.00 |
| March | 0.280841E+09 | 0.843076E+09 | 0.558092E+09 | 0.173530E+09 | 0.384562E+09 | 0.00 | 0.00 |
| April | 0.589717E+09 | 0.483904E+09 | 0.732690E+09 | 0.252554E+09 | 0.480136E+09 | 0.00 | 0.00 |
| May | 0.940347E+09 | 0.268635E+09 | 0.910405E+09 | 0.249908E+09 | 0.660497E+09 | 0.00 | 0.00 |
| June | 0.114460E+10 | 0.180666E+09 | 0.990143E+09 | 0.318371E+09 | 0.671772E+09 | 0.00 | 0.00 |
| July | 0.118644E+10 | 0.171931E+09 | 0.992669E+09 | 0.306912E+09 | 0.685756E+09 | 0.00 | 0.00 |
| August | 0.857412E+09 | 0.205901E+09 | 0.760421E+09 | 0.199831E+09 | 0.560590E+09 | 0.00 | 0.00 |
| September | 0.562639E+09 | 0.311379E+09 | 0.583101E+09 | 0.154623E+09 | 0.428478E+09 | 0.00 | 0.00 |
| October | 0.246308E+09 | 0.512678E+09 | 0.385389E+09 | 80734764.76 | 0.304655E+09 | 0.00 | 0.00 |
| November | 62878676.45 | 0.804453E+09 | 0.242289E+09 | 44208928.19 | 0.198080E+09 | 0.00 | 0.00 |
| December | 7740331.99 | 0.137793E+10 | 0.220814E+09 | 47027250.96 | 0.173787E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.601086E+10 | 0.757241E+10 | 0.703580E+10 | 0.199434E+10 | 0.504146E+10 | 0.00 | 0.00 |
| Minimum of Months | 7740331.99 | 0.171931E+09 | 0.220814E+09 | 44208928.19 | 0.173787E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.118644E+10 | 0.141828E+10 | 0.992669E+09 | 0.318371E+09 | 0.685756E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 981790.23 | 0.934432E+09 | 0.111995E+09 | 0.00 | 0.111995E+09 | 0.00 | 0.00 |
| February | 14164924.34 | 0.661135E+09 | 0.155385E+09 | 0.00 | 0.155385E+09 | 0.00 | 0.00 |
| March | 44041156.41 | 0.557819E+09 | 0.211714E+09 | 15171.03 | 0.211698E+09 | 0.00 | 0.00 |
| April | 0.147663E+09 | 0.311841E+09 | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.00 | 0.00 |
| May | 0.367631E+09 | 0.166337E+09 | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.00 | 0.00 |
| June | 0.468833E+09 | 0.111646E+09 | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.00 | 0.00 |
| July | 0.482881E+09 | 0.105393E+09 | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.00 | 0.00 |
| August | 0.335321E+09 | 0.128089E+09 | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.00 | 0.00 |
| September | 0.198487E+09 | 0.199236E+09 | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.00 | 0.00 |
| October | 78092211.17 | 0.327585E+09 | 0.170963E+09 | 0.00 | 0.170963E+09 | 0.00 | 0.00 |
| November | 11683172.17 | 0.519530E+09 | 0.109547E+09 | 0.00 | 0.109547E+09 | 0.00 | 0.00 |
| December | 11403.50 | 0.895081E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.214979E+10 | 0.491813E+10 | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.00 | 0.00 |
| Minimum of Months | 11403.50 | 0.105393E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Maximum of Months | 0.482881E+09 | 0.934432E+09 | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 981379.93 | 0.934435E+09 | 0.111995E+09 | 0.00 | 0.111995E+09 | 0.00 | 0.00 |
| February | 14150760.69 | 0.661110E+09 | 0.155385E+09 | 0.00 | 0.155385E+09 | 0.00 | 0.00 |
| March | 43984840.29 | 0.557725E+09 | 0.211714E+09 | 15171.03 | 0.211698E+09 | 0.00 | 0.00 |
| April | 0.147368E+09 | 0.311703E+09 | 0.269111E+09 | 2637756.90 | 0.266474E+09 | 0.00 | 0.00 |
| May | 0.367303E+09 | 0.166190E+09 | 0.390601E+09 | 21032867.76 | 0.369568E+09 | 0.00 | 0.00 |
| June | 0.468567E+09 | 0.111577E+09 | 0.421304E+09 | 46097638.03 | 0.375206E+09 | 0.00 | 0.00 |
| July | 0.482792E+09 | 0.105288E+09 | 0.415524E+09 | 35131482.92 | 0.380392E+09 | 0.00 | 0.00 |
| August | 0.335191E+09 | 0.127995E+09 | 0.317106E+09 | 6409345.67 | 0.310696E+09 | 0.00 | 0.00 |
| September | 0.198155E+09 | 0.199142E+09 | 0.238520E+09 | 171924.36 | 0.238348E+09 | 0.00 | 0.00 |
| October | 78004669.24 | 0.327448E+09 | 0.170963E+09 | 0.00 | 0.170963E+09 | 0.00 | 0.00 |
| November | 11675053.14 | 0.519525E+09 | 0.109547E+09 | 0.00 | 0.109547E+09 | 0.00 | 0.00 |
| December | 11387.20 | 0.895088E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.214818E+10 | 0.491723E+10 | 0.290666E+10 | 0.111496E+09 | 0.279516E+10 | 0.00 | 0.00 |
| Minimum of Months | 11387.20 | 0.105288E+09 | 94891471.55 | 0.00 | 94891471.55 | 0.00 | 0.00 |
| Maximum of Months | 0.482792E+09 | 0.934435E+09 | 0.421304E+09 | 46097638.03 | 0.380392E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.659899E+09 | 0.748230E+09 | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.00 | 0.00 |
| February | 0.847301E+09 | 0.563347E+09 | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.00 | 0.00 |
| March | 0.838293E+09 | 0.508392E+09 | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.00 | 0.00 |
| April | 0.813339E+09 | 0.320033E+09 | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.00 | 0.00 |
| May | 0.770132E+09 | 0.184703E+09 | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.00 | 0.00 |
| June | 0.704250E+09 | 0.121433E+09 | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.00 | 0.00 |
| July | 0.837170E+09 | 0.113235E+09 | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.00 | 0.00 |
| August | 0.846829E+09 | 0.134727E+09 | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.00 | 0.00 |
| September | 0.819176E+09 | 0.204689E+09 | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.00 | 0.00 |
| October | 0.662228E+09 | 0.317080E+09 | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.00 | 0.00 |
| November | 0.494620E+09 | 0.456299E+09 | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.00 | 0.00 |
| December | 0.472060E+09 | 0.724510E+09 | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.876530E+10 | 0.439668E+10 | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.472060E+09 | 0.113235E+09 | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.847301E+09 | 0.748230E+09 | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.659864E+09 | 0.748204E+09 | 0.772046E+09 | 0.536708E+09 | 0.235338E+09 | 0.00 | 0.00 |
| February | 0.847242E+09 | 0.563260E+09 | 0.880058E+09 | 0.593777E+09 | 0.286281E+09 | 0.00 | 0.00 |
| March | 0.838141E+09 | 0.508245E+09 | 0.849544E+09 | 0.533680E+09 | 0.315864E+09 | 0.00 | 0.00 |
| April | 0.813022E+09 | 0.319903E+09 | 0.755201E+09 | 0.410240E+09 | 0.344961E+09 | 0.00 | 0.00 |
| May | 0.769897E+09 | 0.184524E+09 | 0.660412E+09 | 0.229097E+09 | 0.431315E+09 | 0.00 | 0.00 |
| June | 0.704000E+09 | 0.121348E+09 | 0.570384E+09 | 0.152969E+09 | 0.417415E+09 | 0.00 | 0.00 |
| July | 0.837053E+09 | 0.113115E+09 | 0.650581E+09 | 0.211275E+09 | 0.439306E+09 | 0.00 | 0.00 |
| August | 0.846732E+09 | 0.134622E+09 | 0.678985E+09 | 0.279534E+09 | 0.399451E+09 | 0.00 | 0.00 |
| September | 0.819040E+09 | 0.204550E+09 | 0.702943E+09 | 0.370213E+09 | 0.332729E+09 | 0.00 | 0.00 |
| October | 0.662169E+09 | 0.316953E+09 | 0.636017E+09 | 0.377275E+09 | 0.258742E+09 | 0.00 | 0.00 |
| November | 0.494578E+09 | 0.456271E+09 | 0.539514E+09 | 0.337605E+09 | 0.201910E+09 | 0.00 | 0.00 |
| December | 0.472035E+09 | 0.724496E+09 | 0.596332E+09 | 0.391213E+09 | 0.205120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.876377E+10 | 0.439549E+10 | 0.829202E+10 | 0.442359E+10 | 0.386843E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.472035E+09 | 0.113115E+09 | 0.539514E+09 | 0.152969E+09 | 0.201910E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.847242E+09 | 0.748204E+09 | 0.880058E+09 | 0.593777E+09 | 0.439306E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 15798916.71 | 0.132034E+09 | 38973548.37 | 16340591.89 | 22632956.48 | 0.00 | 0.00 |
| February | 33698477.33 | 94410824.85 | 55185765.92 | 23646469.55 | 31539296.37 | 0.00 | 0.00 |
| March | 64841193.88 | 82377089.06 | 83114789.83 | 41635478.20 | 41479311.63 | 0.00 | 0.00 |
| April | 0.109106E+09 | 49699204.14 | 0.111238E+09 | 59968388.59 | 51269281.63 | 0.00 | 0.00 |
| May | 0.136718E+09 | 29682315.37 | 0.124729E+09 | 54919603.03 | 69809609.86 | 0.00 | 0.00 |
| June | 0.161023E+09 | 20641290.90 | 0.136495E+09 | 65333035.87 | 71162298.18 | 0.00 | 0.00 |
| July | 0.167126E+09 | 19580700.89 | 0.138488E+09 | 65214865.22 | 73273391.62 | 0.00 | 0.00 |
| August | 0.123445E+09 | 23291069.40 | 0.106375E+09 | 46412274.88 | 59963054.04 | 0.00 | 0.00 |
| September | 87194384.05 | 33766957.00 | 82683514.98 | 37061203.23 | 45622311.75 | 0.00 | 0.00 |
| October | 41173122.94 | 52287648.43 | 51452582.22 | 19372635.43 | 32079946.79 | 0.00 | 0.00 |
| November | 15845527.08 | 77373663.25 | 31851961.04 | 10608112.27 | 21243848.78 | 0.00 | 0.00 |
| December | 9799954.28 | 0.128172E+09 | 30215682.78 | 11284380.29 | 18931302.49 | 0.00 | 0.00 |
| Annual Sum or Average | 0.965769E+09 | 0.743317E+09 | 0.990804E+09 | 0.451797E+09 | 0.539007E+09 | 0.00 | 0.00 |
| Minimum of Months | 9799954.28 | 19580700.89 | 30215682.78 | 10608112.27 | 18931302.49 | 0.00 | 0.00 |
| Maximum of Months | 0.167126E+09 | 0.132034E+09 | 0.138488E+09 | 65333035.87 | 73273391.62 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 54590532.83 | 0.340738E+09 | 0.116073E+09 | 48666349.22 | 67406576.91 | 0.00 | 0.00 |
| February | 0.111914E+09 | 0.245552E+09 | 0.164357E+09 | 70425071.06 | 93931873.56 | 0.00 | 0.00 |
| March | 0.207914E+09 | 0.212325E+09 | 0.247537E+09 | 0.124001E+09 | 0.123536E+09 | 0.00 | 0.00 |
| April | 0.341307E+09 | 0.130535E+09 | 0.331293E+09 | 0.178601E+09 | 0.152693E+09 | 0.00 | 0.00 |
| May | 0.420629E+09 | 79963039.87 | 0.371475E+09 | 0.163564E+09 | 0.207910E+09 | 0.00 | 0.00 |
| June | 0.486157E+09 | 59057099.92 | 0.406517E+09 | 0.194578E+09 | 0.211939E+09 | 0.00 | 0.00 |
| July | 0.499789E+09 | 59165051.85 | 0.412452E+09 | 0.194226E+09 | 0.218226E+09 | 0.00 | 0.00 |
| August | 0.370012E+09 | 70145668.01 | 0.316812E+09 | 0.138227E+09 | 0.178585E+09 | 0.00 | 0.00 |
| September | 0.260809E+09 | 0.101287E+09 | 0.246252E+09 | 0.110377E+09 | 0.135875E+09 | 0.00 | 0.00 |
| October | 0.127825E+09 | 0.146443E+09 | 0.153239E+09 | 57696529.44 | 95542065.08 | 0.00 | 0.00 |
| November | 52613104.80 | 0.205472E+09 | 94863066.78 | 31593598.30 | 63269468.48 | 0.00 | 0.00 |
| December | 34223548.91 | 0.332070E+09 | 89989822.89 | 33607692.76 | 56382130.13 | 0.00 | 0.00 |
| Annual Sum or Average | 0.296778E+10 | 0.198275E+10 | 0.295086E+10 | 0.134556E+10 | 0.160530E+10 | 0.00 | 0.00 |
| Minimum of Months | 34223548.91 | 59057099.92 | 89989822.89 | 31593598.30 | 56382130.13 | 0.00 | 0.00 |
| Maximum of Months | 0.499789E+09 | 0.340738E+09 | 0.412452E+09 | 0.194578E+09 | 0.218226E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 14922823.65 | 0.139467E+09 | 38973548.37 | 16340591.89 | 22632956.48 | 0.00 | 0.00 |
| February | 32477491.72 | 99766525.84 | 55185765.92 | 23646469.55 | 31539296.37 | 0.00 | 0.00 |
| March | 63385570.34 | 87061402.03 | 83114789.83 | 41635478.20 | 41479311.63 | 0.00 | 0.00 |
| April | 0.107359E+09 | 52764412.85 | 0.111238E+09 | 59968388.59 | 51269281.63 | 0.00 | 0.00 |
| May | 0.134761E+09 | 31485960.82 | 0.124729E+09 | 54919603.03 | 69809609.86 | 0.00 | 0.00 |
| June | 0.160273E+09 | 21681955.30 | 0.136495E+09 | 65333035.87 | 71162298.18 | 0.00 | 0.00 |
| July | 0.166991E+09 | 20174699.92 | 0.138488E+09 | 65214865.22 | 73273391.62 | 0.00 | 0.00 |
| August | 0.122819E+09 | 24390344.19 | 0.106375E+09 | 46412274.88 | 59963054.04 | 0.00 | 0.00 |
| September | 84777099.31 | 37064358.89 | 82683514.98 | 37061203.23 | 45622311.75 | 0.00 | 0.00 |
| October | 39401054.84 | 56449696.84 | 51452582.22 | 19372635.43 | 32079946.79 | 0.00 | 0.00 |
| November | 15027240.77 | 82427496.98 | 31851961.04 | 10608112.27 | 21243848.78 | 0.00 | 0.00 |
| December | 9233499.96 | 0.135551E+09 | 30215682.78 | 11284380.29 | 18931302.49 | 0.00 | 0.00 |
| Annual Sum or Average | 0.951427E+09 | 0.788285E+09 | 0.990804E+09 | 0.451797E+09 | 0.539007E+09 | 0.00 | 0.00 |
| Minimum of Months | 9233499.96 | 20174699.92 | 30215682.78 | 10608112.27 | 18931302.49 | 0.00 | 0.00 |
| Maximum of Months | 0.166991E+09 | 0.139467E+09 | 0.138488E+09 | 65333035.87 | 73273391.62 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | -16.9 | -17.4 | -20.0 | 3.73 | -31.9 | 33.25 | 98.18 | 0.00 |
| February | -11.6 | -12.7 | -16.7 | 4.33 | -26.7 | 48.91 | 138.70 | 0.00 |
| March | -6.2 | -7.6 | -10.8 | 3.55 | -19.4 | 56.69 | 163.76 | 0.01 |
| April | 3.97 | 0.41 | -4.8 | 4.72 | -9.1 | 70.41 | 207.70 | 0.01 |
| May | 13.43 | 8.45 | 3.53 | 3.60 | 2.20 | 102.27 | 202.62 | 0.00 |
| June | 18.03 | 14.19 | 11.55 | 3.74 | 7.84 | 104.36 | 210.60 | 0.06 |
| July | 19.67 | 16.51 | 14.78 | 3.14 | 8.97 | 101.67 | 223.82 | 0.04 |
| August | 17.94 | 15.20 | 13.59 | 3.45 | 8.99 | 87.39 | 175.79 | 0.04 |
| September | 12.29 | 9.87 | 7.80 | 3.78 | 3.34 | 70.27 | 143.96 | 0.00 |
| October | 5.42 | 3.47 | 1.07 | 3.53 | -4.7 | 51.74 | 90.11 | 0.00 |
| November | -2.0 | -3.6 | -6.9 | 4.42 | -13.7 | 34.68 | 65.95 | 0.00 |
| December | -14.6 | -15.1 | -18.1 | 3.91 | -28.3 | 29.58 | 68.99 | 0.00 |
| Annual Sum or Average | 3.36 | 1.04 | -2.0 | 3.82 | -8.4 | 66.03 | 149.18 | 0.01 |
| Minimum of Months | -16.9 | -17.4 | -20.0 | 3.14 | -31.9 | 29.58 | 65.95 | 0.00 |
| Maximum of Months | 19.67 | 16.51 | 14.78 | 4.72 | 8.99 | 104.36 | 223.82 | 0.06 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 1.10 | 29-JAN-14:00 | -1.0 | -4.4 | 2.60 | -11.4 | 145.00 | 110.00 |
| February | 8.90 | 20-FEB-15:00 | 2.87 | -6.7 | 8.80 | -9.0 | 49.00 | 646.00 |
| March | 11.10 | 26-MAR-15:00 | 5.48 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
| April | 26.70 | 23-APR-15:00 | 16.95 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
| May | 29.40 | 25-MAY-17:00 | 19.26 | 13.90 | 1.50 | 16.49 | 47.50 | 582.00 |
| June | 35.00 | 29-JUN-15:00 | 24.72 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
| July | 31.10 | 15-JUL-14:20 | 25.35 | 23.33 | 8.07 | 19.93 | 299.67 | 518.33 |
| August | 30.60 | 08-AUG-14:00 | 23.36 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
| September | 26.10 | 01-SEP-14:00 | 17.82 | 13.30 | 3.60 | 14.28 | 112.00 | 751.50 |
| October | 22.20 | 19-OCT-14:00 | 13.62 | 7.20 | 6.70 | 8.15 | 35.50 | 701.50 |
| November | 18.30 | 01-NOV-14:00 | 13.44 | 10.00 | 3.10 | 11.84 | 105.00 | 30.50 |
| December | 1.10 | 28-DEC-02:00 | 0.43 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 1.10 | -1.0 | -6.7 | 1.50 | -11.4 | 0.00 | 0.00 | |
| Maximum of Months | 35.00 | 25.35 | 23.33 | 11.30 | 24.66 | 299.67 | 842.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -35.6 | 06-JAN-08:00 | -35.7 | -37.8 | 0.00 | -57.8 | 27.00 | 381.00 |
| February | -33.3 | 14-FEB-06:00 | -33.4 | -36.7 | 0.00 | -55.6 | 0.00 | 0.00 |
| March | -28.9 | 05-MAR-06:00 | -29.1 | -32.2 | 1.50 | -50.6 | 27.00 | 41.50 |
| April | -13.9 | 05-APR-05:00 | -14.4 | -16.1 | 0.00 | -32.5 | 14.50 | 199.00 |
| May | -3.9 | 01-MAY-05:00 | -6.2 | -12.2 | 0.00 | -22.4 | 35.00 | 415.00 |
| June | 1.10 | 04-JUN-04:00 | 0.62 | 0.00 | 0.00 | -14.9 | 37.00 | 169.50 |
| July | 6.10 | 02-JUL-04:00 | 6.10 | 6.10 | 0.00 | -8.8 | 33.50 | 204.50 |
| August | 4.40 | 19-AUG-03:00 | 4.40 | 4.40 | 0.00 | -10.7 | 0.00 | 0.00 |
| September | 1.10 | 06-SEP-03:00 | 1.10 | 1.10 | 0.00 | -14.7 | 0.00 | 0.00 |
| October | -10.0 | 30-OCT-03:00 | -10.7 | -12.8 | 1.50 | -28.2 | 0.00 | 0.00 |
| November | -20.6 | 29-NOV-05:00 | -20.8 | -22.2 | 2.10 | -37.8 | 0.00 | 0.00 |
| December | -31.1 | 24-DEC-06:19 | -31.3 | -35.1 | 3.33 | -53.1 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -35.6 | -35.7 | -37.8 | 0.00 | -57.8 | 0.00 | 0.00 | |
| Maximum of Months | 6.10 | 6.10 | 6.10 | 3.33 | -8.8 | 37.00 | 415.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -0.5 | 16-JAN-12:00 | 0.00 | -1.1 | 5.70 | -6.6 | 172.50 | 3.00 |
| February | 3.34 | 21-FEB-12:00 | 6.70 | -1.1 | 7.70 | -6.0 | 270.00 | 303.00 |
| March | 5.48 | 26-MAR-15:00 | 11.10 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
| April | 16.95 | 23-APR-15:00 | 26.70 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
| May | 19.91 | 26-MAY-11:00 | 25.60 | 17.20 | 6.20 | 22.64 | 300.50 | 6.00 |
| June | 24.72 | 29-JUN-15:00 | 35.00 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
| July | 25.76 | 15-JUL-13:00 | 31.10 | 23.90 | 7.70 | 18.99 | 333.00 | 421.00 |
| August | 23.36 | 08-AUG-14:00 | 30.60 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
| September | 18.67 | 01-SEP-00:00 | 19.00 | 17.50 | 2.80 | 16.30 | 0.00 | 0.00 |
| October | 13.72 | 19-OCT-13:00 | 21.70 | 7.80 | 5.70 | 7.75 | 54.50 | 739.00 |
| November | 14.29 | 21-NOV-12:00 | 15.00 | 13.90 | 5.20 | 11.46 | 134.50 | 25.50 |
| December | 0.43 | 28-DEC-02:00 | 1.10 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -0.5 | 0.00 | -1.1 | 2.80 | -6.6 | 0.00 | 0.00 | |
| Maximum of Months | 25.76 | 35.00 | 23.90 | 11.30 | 24.66 | 333.00 | 842.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -1.1 | 16-JAN-11:00 | -0.6 | -0.8 | 5.70 | -7.3 | 164.50 | 5.00 |
| February | -0.6 | 21-FEB-08:00 | 4.40 | 2.25 | 8.80 | -6.6 | 123.00 | 89.50 |
| March | 0.00 | 29-MAR-20:00 | 1.70 | 0.95 | 1.50 | -4.8 | 0.00 | 0.00 |
| April | 11.10 | 23-APR-13:00 | 24.40 | 16.08 | 10.80 | 9.72 | 98.50 | 903.50 |
| May | 17.20 | 26-MAY-11:00 | 25.60 | 19.91 | 6.20 | 22.64 | 300.50 | 6.00 |
| June | 22.80 | 29-JUN-23:19 | 26.30 | 23.71 | 5.20 | 14.28 | 0.00 | 0.00 |
| July | 23.90 | 15-JUL-13:00 | 31.10 | 25.76 | 7.70 | 18.99 | 333.00 | 421.00 |
| August | 20.60 | 08-AUG-14:00 | 30.60 | 23.36 | 6.70 | 17.93 | 163.50 | 672.50 |
| September | 17.92 | 01-SEP-00:10 | 19.75 | 18.15 | 3.22 | 13.23 | 0.00 | 0.00 |
| October | 12.20 | 07-OCT-12:20 | 14.47 | 13.17 | 3.43 | 9.20 | 163.17 | 18.50 |
| November | 13.90 | 21-NOV-12:00 | 15.00 | 14.29 | 5.20 | 11.46 | 134.50 | 25.50 |
| December | -0.0 | 05-DEC-17:00 | 0.00 | -0.0 | 1.50 | -6.4 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -1.1 | -0.6 | -0.8 | 1.50 | -7.3 | 0.00 | 0.00 | |
| Maximum of Months | 23.90 | 31.10 | 25.76 | 10.80 | 22.64 | 333.00 | 903.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 1.89 | 11.66 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 0.58 | 19.92 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 0.81 | 26.63 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 2.58 | 37.52 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 5.43 | 45.25 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 8.61 | 47.76 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 11.25 | 48.86 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 12.66 | 38.94 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 12.41 | 29.23 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 10.60 | 17.37 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 7.72 | 10.89 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 4.55 | 9.11 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 6.63 | 28.63 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 0.58 | 9.11 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 12.66 | 48.86 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168543539.3 | 59.44 | 0.00 | 0.00 |
| March | 0.144716E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186564924.8 | 59.44 | 0.00 | 0.00 |
| April | 0.136255E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179306459.9 | 59.44 | 0.00 | 0.00 |
| May | 0.133960E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178375911.4 | 59.44 | 0.00 | 0.00 |
| June | 0.122635E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168699938.7 | 59.44 | 0.00 | 0.00 |
| July | 0.120869E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172557848.9 | 59.44 | 0.00 | 0.00 |
| August | 0.117863E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172724676.2 | 59.44 | 0.00 | 0.00 |
| September | 0.114823E+10 | -978625682.3 | 0.00 | 0.00 | 720.00 | 0.00 | -169608159.9 | 59.44 | 0.00 | 0.00 |
| October | 0.123336E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183127931.4 | 59.44 | 0.00 | 0.00 |
| November | 0.125676E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180538137.1 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601971.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155039E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213325E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.114823E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144716E+10 | -978625682.3 | 0.00 | 0.00 | 744.00 | 0.00 | -168543539.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546213.0 | 59.44 | 0.00 | 0.00 |
| March | 0.144720E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186607761.3 | 59.44 | 0.00 | 0.00 |
| April | 0.136357E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180327605.4 | 59.44 | 0.00 | 0.00 |
| May | 0.134122E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179990451.6 | 59.44 | 0.00 | 0.00 |
| June | 0.122671E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169060584.1 | 59.44 | 0.00 | 0.00 |
| July | 0.120873E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172596068.6 | 59.44 | 0.00 | 0.00 |
| August | 0.117877E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172866604.4 | 59.44 | 0.00 | 0.00 |
| September | 0.115040E+10 | -978624602.6 | 0.00 | 0.00 | 720.00 | 0.00 | -171774776.3 | 59.44 | 0.00 | 0.00 |
| October | 0.123615E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185915645.1 | 59.44 | 0.00 | 0.00 |
| November | 0.125680E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180574465.4 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603376.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155121E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214147E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115040E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186607761.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144720E+10 | -978624602.6 | 0.00 | 0.00 | 744.00 | 0.00 | -168546213.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546212.9 | 59.44 | 0.00 | 0.00 |
| March | 0.144720E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186607761.3 | 59.44 | 0.00 | 0.00 |
| April | 0.136364E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180397563.8 | 59.44 | 0.00 | 0.00 |
| May | 0.134139E+10 | -0.116123E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180160953.1 | 59.44 | 0.00 | 0.00 |
| June | 0.122633E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168681260.1 | 59.44 | 0.00 | 0.00 |
| July | 0.120878E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172644421.0 | 59.44 | 0.00 | 0.00 |
| August | 0.117874E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172833197.2 | 59.44 | 0.00 | 0.00 |
| September | 0.115030E+10 | -978625618.4 | 0.00 | 0.00 | 720.00 | 0.00 | -171673591.6 | 59.44 | 0.00 | 0.00 |
| October | 0.123621E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185971107.1 | 59.44 | 0.00 | 0.00 |
| November | 0.125680E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180574672.4 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603380.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155120E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214130E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115030E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186607761.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144720E+10 | -978625618.4 | 0.00 | 0.00 | 744.00 | 0.00 | -168546212.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.6 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546212.8 | 59.44 | 0.00 | 0.00 |
| March | 0.144720E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186607761.2 | 59.44 | 0.00 | 0.00 |
| April | 0.136366E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180419119.5 | 59.44 | 0.00 | 0.00 |
| May | 0.134090E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179673126.2 | 59.44 | 0.00 | 0.00 |
| June | 0.122589E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168243192.8 | 59.44 | 0.00 | 0.00 |
| July | 0.120867E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172542132.9 | 59.44 | 0.00 | 0.00 |
| August | 0.117855E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172646416.1 | 59.44 | 0.00 | 0.00 |
| September | 0.114928E+10 | -978624680.8 | 0.00 | 0.00 | 720.00 | 0.00 | -170652956.5 | 59.44 | 0.00 | 0.00 |
| October | 0.123599E+10 | -0.105024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185750083.3 | 59.44 | 0.00 | 0.00 |
| November | 0.125678E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180558662.5 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601851.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155095E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213885E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.114928E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186607761.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144720E+10 | -978624680.8 | 0.00 | 0.00 | 744.00 | 0.00 | -168243192.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.6 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546212.8 | 59.44 | 0.00 | 0.00 |
| March | 0.144720E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186607761.2 | 59.44 | 0.00 | 0.00 |
| April | 0.136367E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180420647.9 | 59.44 | 0.00 | 0.00 |
| May | 0.134092E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179692749.6 | 59.44 | 0.00 | 0.00 |
| June | 0.122585E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168204799.0 | 59.44 | 0.00 | 0.00 |
| July | 0.120868E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172544957.2 | 59.44 | 0.00 | 0.00 |
| August | 0.117855E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172644782.2 | 59.44 | 0.00 | 0.00 |
| September | 0.114927E+10 | -978624725.5 | 0.00 | 0.00 | 720.00 | 0.00 | -170644205.3 | 59.44 | 0.00 | 0.00 |
| October | 0.123599E+10 | -0.105024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185756085.4 | 59.44 | 0.00 | 0.00 |
| November | 0.125678E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180558337.5 | 59.44 | 0.00 | 0.00 |
| December | 0.136693E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601809.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155095E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213883E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.114927E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186607761.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144720E+10 | -978624725.5 | 0.00 | 0.00 | 744.00 | 0.00 | -168204799.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131168E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168530484.1 | 59.44 | 0.00 | 0.00 |
| March | 0.144715E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186559755.6 | 59.44 | 0.00 | 0.00 |
| April | 0.136231E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179066411.9 | 59.44 | 0.00 | 0.00 |
| May | 0.133890E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177679290.2 | 59.44 | 0.00 | 0.00 |
| June | 0.122556E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167914360.3 | 59.44 | 0.00 | 0.00 |
| July | 0.120864E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172511130.7 | 59.44 | 0.00 | 0.00 |
| August | 0.117848E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172570176.7 | 59.44 | 0.00 | 0.00 |
| September | 0.114716E+10 | -978625497.2 | 0.00 | 0.00 | 720.00 | 0.00 | -168533645.9 | 59.44 | 0.00 | 0.00 |
| October | 0.123232E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182086164.1 | 59.44 | 0.00 | 0.00 |
| November | 0.125668E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180463582.6 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602027.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154998E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212912E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.114716E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144715E+10 | -978625497.2 | 0.00 | 0.00 | 744.00 | 0.00 | -167914360.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131169E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168540357.6 | 59.44 | 0.00 | 0.00 |
| March | 0.144717E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186581582.6 | 59.44 | 0.00 | 0.00 |
| April | 0.136236E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179116003.8 | 59.44 | 0.00 | 0.00 |
| May | 0.133878E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177559834.2 | 59.44 | 0.00 | 0.00 |
| June | 0.122540E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167754149.0 | 59.44 | 0.00 | 0.00 |
| July | 0.120864E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172505171.7 | 59.44 | 0.00 | 0.00 |
| August | 0.117845E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172547662.2 | 59.44 | 0.00 | 0.00 |
| September | 0.114699E+10 | -978626368.5 | 0.00 | 0.00 | 720.00 | 0.00 | -168365231.5 | 59.44 | 0.00 | 0.00 |
| October | 0.123223E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181993517.2 | 59.44 | 0.00 | 0.00 |
| November | 0.125671E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180487229.2 | 59.44 | 0.00 | 0.00 |
| December | 0.136693E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603740.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154993E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212866E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.114699E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144717E+10 | -978626368.5 | 0.00 | 0.00 | 744.00 | 0.00 | -167754149.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266137E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601157.0 | 59.44 | 0.00 | 0.00 |
| February | 0.245456E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168250953.7 | 59.44 | 0.00 | 0.00 |
| March | 0.270683E+10 | -0.252120E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185634194.0 | 59.44 | 0.00 | 0.00 |
| April | 0.254222E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175723177.8 | 59.44 | 0.00 | 0.00 |
| May | 0.249654E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174085126.8 | 59.44 | 0.00 | 0.00 |
| June | 0.228241E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167113617.1 | 59.44 | 0.00 | 0.00 |
| July | 0.224477E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172500472.4 | 59.44 | 0.00 | 0.00 |
| August | 0.218445E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172630133.3 | 59.44 | 0.00 | 0.00 |
| September | 0.212629E+10 | -0.195726E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169029569.2 | 59.44 | 0.00 | 0.00 |
| October | 0.228261E+10 | -0.210048E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182139152.2 | 59.44 | 0.00 | 0.00 |
| November | 0.233278E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180331610.9 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604611.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288621E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212064E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212629E+10 | -0.252120E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604611.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270683E+10 | -0.195726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167113617.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266137E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604304.0 | 59.44 | 0.00 | 0.00 |
| February | 0.245486E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168544689.3 | 59.44 | 0.00 | 0.00 |
| March | 0.270771E+10 | -0.252119E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186516871.8 | 59.44 | 0.00 | 0.00 |
| April | 0.254484E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178343616.0 | 59.44 | 0.00 | 0.00 |
| May | 0.249727E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174818117.4 | 59.44 | 0.00 | 0.00 |
| June | 0.228242E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167125959.4 | 59.44 | 0.00 | 0.00 |
| July | 0.224478E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172502839.6 | 59.44 | 0.00 | 0.00 |
| August | 0.218449E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172668420.2 | 59.44 | 0.00 | 0.00 |
| September | 0.212758E+10 | -0.195725E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170331085.9 | 59.44 | 0.00 | 0.00 |
| October | 0.228534E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184873705.4 | 59.44 | 0.00 | 0.00 |
| November | 0.233300E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180547250.2 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602161.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288709E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212948E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212758E+10 | -0.252119E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604304.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270771E+10 | -0.195725E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167125959.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266137E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604304.0 | 59.44 | 0.00 | 0.00 |
| February | 0.245461E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168300667.7 | 59.44 | 0.00 | 0.00 |
| March | 0.270690E+10 | -0.252120E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185698933.8 | 59.44 | 0.00 | 0.00 |
| April | 0.254195E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175451316.6 | 59.44 | 0.00 | 0.00 |
| May | 0.249646E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174003555.9 | 59.44 | 0.00 | 0.00 |
| June | 0.228239E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167096407.5 | 59.44 | 0.00 | 0.00 |
| July | 0.224478E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172508783.9 | 59.44 | 0.00 | 0.00 |
| August | 0.218443E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172613083.6 | 59.44 | 0.00 | 0.00 |
| September | 0.212630E+10 | -0.195726E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169047671.5 | 59.44 | 0.00 | 0.00 |
| October | 0.228270E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182224740.5 | 59.44 | 0.00 | 0.00 |
| November | 0.233279E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180335352.3 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604600.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288619E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212049E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212630E+10 | -0.252120E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604600.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270690E+10 | -0.195726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167096407.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266137E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604304.0 | 59.44 | 0.00 | 0.00 |
| February | 0.245486E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168544689.2 | 59.44 | 0.00 | 0.00 |
| March | 0.270779E+10 | -0.252119E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186597608.0 | 59.44 | 0.00 | 0.00 |
| April | 0.254479E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178291539.1 | 59.44 | 0.00 | 0.00 |
| May | 0.249713E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174680831.0 | 59.44 | 0.00 | 0.00 |
| June | 0.228241E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167117439.8 | 59.44 | 0.00 | 0.00 |
| July | 0.224479E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172516414.6 | 59.44 | 0.00 | 0.00 |
| August | 0.218447E+10 | -0.201181E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172652163.1 | 59.44 | 0.00 | 0.00 |
| September | 0.212750E+10 | -0.195726E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170247417.2 | 59.44 | 0.00 | 0.00 |
| October | 0.228546E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184984933.4 | 59.44 | 0.00 | 0.00 |
| November | 0.233300E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180547635.8 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602179.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288708E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212939E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212750E+10 | -0.252119E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604304.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270779E+10 | -0.195726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167117439.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266137E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604303.9 | 59.44 | 0.00 | 0.00 |
| February | 0.245486E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168544689.1 | 59.44 | 0.00 | 0.00 |
| March | 0.270777E+10 | -0.252119E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186579645.5 | 59.44 | 0.00 | 0.00 |
| April | 0.254500E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178501397.2 | 59.44 | 0.00 | 0.00 |
| May | 0.249693E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174471597.7 | 59.44 | 0.00 | 0.00 |
| June | 0.228229E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166991457.3 | 59.44 | 0.00 | 0.00 |
| July | 0.224476E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490876.4 | 59.44 | 0.00 | 0.00 |
| August | 0.218436E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172539654.4 | 59.44 | 0.00 | 0.00 |
| September | 0.212634E+10 | -0.195726E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169086550.1 | 59.44 | 0.00 | 0.00 |
| October | 0.228478E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184305188.7 | 59.44 | 0.00 | 0.00 |
| November | 0.233297E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180514886.2 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599923.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288687E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212723E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212634E+10 | -0.252119E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604303.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270777E+10 | -0.195726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166991457.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266137E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604303.9 | 59.44 | 0.00 | 0.00 |
| February | 0.245486E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168544689.1 | 59.44 | 0.00 | 0.00 |
| March | 0.270777E+10 | -0.252119E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186582451.0 | 59.44 | 0.00 | 0.00 |
| April | 0.254499E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178488591.2 | 59.44 | 0.00 | 0.00 |
| May | 0.249691E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174457077.1 | 59.44 | 0.00 | 0.00 |
| June | 0.228229E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166990857.7 | 59.44 | 0.00 | 0.00 |
| July | 0.224477E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172491359.5 | 59.44 | 0.00 | 0.00 |
| August | 0.218435E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172538389.5 | 59.44 | 0.00 | 0.00 |
| September | 0.212634E+10 | -0.195726E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169085229.0 | 59.44 | 0.00 | 0.00 |
| October | 0.228480E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184321201.4 | 59.44 | 0.00 | 0.00 |
| November | 0.233297E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180514714.7 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599917.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288687E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212722E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212634E+10 | -0.252119E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604303.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270777E+10 | -0.195726E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166990857.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266136E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186592287.1 | 59.44 | 0.00 | 0.00 |
| February | 0.245435E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168033256.9 | 59.44 | 0.00 | 0.00 |
| March | 0.270658E+10 | -0.252119E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185390993.4 | 59.44 | 0.00 | 0.00 |
| April | 0.254133E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174829170.5 | 59.44 | 0.00 | 0.00 |
| May | 0.249603E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173580007.0 | 59.44 | 0.00 | 0.00 |
| June | 0.228229E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166989507.0 | 59.44 | 0.00 | 0.00 |
| July | 0.224476E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172489937.1 | 59.44 | 0.00 | 0.00 |
| August | 0.218434E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172524833.9 | 59.44 | 0.00 | 0.00 |
| September | 0.212526E+10 | -0.195725E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168003667.6 | 59.44 | 0.00 | 0.00 |
| October | 0.228127E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180801900.1 | 59.44 | 0.00 | 0.00 |
| November | 0.233246E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180005912.8 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602803.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288573E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211584E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212526E+10 | -0.252119E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186602803.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270658E+10 | -0.195725E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166989507.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.266136E+10 | -0.247477E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186592273.3 | 59.44 | 0.00 | 0.00 |
| February | 0.245435E+10 | -0.228631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168034783.5 | 59.44 | 0.00 | 0.00 |
| March | 0.270658E+10 | -0.252119E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185391732.7 | 59.44 | 0.00 | 0.00 |
| April | 0.254130E+10 | -0.236650E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174808062.9 | 59.44 | 0.00 | 0.00 |
| May | 0.249603E+10 | -0.232245E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173576188.1 | 59.44 | 0.00 | 0.00 |
| June | 0.228229E+10 | -0.211530E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166986583.2 | 59.44 | 0.00 | 0.00 |
| July | 0.224476E+10 | -0.207227E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172490192.8 | 59.44 | 0.00 | 0.00 |
| August | 0.218434E+10 | -0.201182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172524158.1 | 59.44 | 0.00 | 0.00 |
| September | 0.212527E+10 | -0.195725E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168011266.2 | 59.44 | 0.00 | 0.00 |
| October | 0.228129E+10 | -0.210047E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180816634.6 | 59.44 | 0.00 | 0.00 |
| November | 0.233246E+10 | -0.215245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180003306.2 | 59.44 | 0.00 | 0.00 |
| December | 0.254725E+10 | -0.236065E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602723.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.288573E+11 | -0.267414E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211584E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.212527E+10 | -0.252119E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186602723.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.270658E+10 | -0.195725E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166986583.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142398E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186600319.2 | 59.44 | 0.00 | 0.00 |
| February | 0.131132E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168165918.8 | 59.44 | 0.00 | 0.00 |
| March | 0.144612E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185523714.3 | 59.44 | 0.00 | 0.00 |
| April | 0.136049E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177242891.6 | 59.44 | 0.00 | 0.00 |
| May | 0.133845E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177224597.3 | 59.44 | 0.00 | 0.00 |
| June | 0.122667E+10 | -0.105764E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169027385.4 | 59.44 | 0.00 | 0.00 |
| July | 0.120950E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173362235.2 | 59.44 | 0.00 | 0.00 |
| August | 0.118006E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174158952.1 | 59.44 | 0.00 | 0.00 |
| September | 0.115182E+10 | -978625521.9 | 0.00 | 0.00 | 720.00 | 0.00 | -173191370.4 | 59.44 | 0.00 | 0.00 |
| October | 0.123447E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184239843.9 | 59.44 | 0.00 | 0.00 |
| November | 0.125656E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180335760.4 | 59.44 | 0.00 | 0.00 |
| December | 0.136693E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604685.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155064E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213568E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115182E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604685.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144612E+10 | -978625521.9 | 0.00 | 0.00 | 744.00 | 0.00 | -168165918.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.8 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546213.2 | 59.44 | 0.00 | 0.00 |
| March | 0.144708E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186488933.9 | 59.44 | 0.00 | 0.00 |
| April | 0.136205E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178801256.3 | 59.44 | 0.00 | 0.00 |
| May | 0.133913E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177905923.1 | 59.44 | 0.00 | 0.00 |
| June | 0.122664E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168993641.6 | 59.44 | 0.00 | 0.00 |
| July | 0.120947E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173339264.2 | 59.44 | 0.00 | 0.00 |
| August | 0.118027E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174369169.7 | 59.44 | 0.00 | 0.00 |
| September | 0.115328E+10 | -978626539.5 | 0.00 | 0.00 | 720.00 | 0.00 | -174656752.0 | 59.44 | 0.00 | 0.00 |
| October | 0.123593E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185698609.7 | 59.44 | 0.00 | 0.00 |
| November | 0.125677E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180545609.7 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602359.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155132E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214255E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115328E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144708E+10 | -978626539.5 | 0.00 | 0.00 | 744.00 | 0.00 | -168546213.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.8 | 59.44 | 0.00 | 0.00 |
| February | 0.131139E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168241007.3 | 59.44 | 0.00 | 0.00 |
| March | 0.144617E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185573707.6 | 59.44 | 0.00 | 0.00 |
| April | 0.136024E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176997012.8 | 59.44 | 0.00 | 0.00 |
| May | 0.133824E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177015287.1 | 59.44 | 0.00 | 0.00 |
| June | 0.122640E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168751015.5 | 59.44 | 0.00 | 0.00 |
| July | 0.120945E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173311099.8 | 59.44 | 0.00 | 0.00 |
| August | 0.117997E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174066254.4 | 59.44 | 0.00 | 0.00 |
| September | 0.115170E+10 | -978625923.9 | 0.00 | 0.00 | 720.00 | 0.00 | -173078400.4 | 59.44 | 0.00 | 0.00 |
| October | 0.123449E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184254272.9 | 59.44 | 0.00 | 0.00 |
| November | 0.125657E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180345984.1 | 59.44 | 0.00 | 0.00 |
| December | 0.136693E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601889.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155055E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213484E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115170E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144617E+10 | -978625923.9 | 0.00 | 0.00 | 744.00 | 0.00 | -168241007.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.8 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546213.1 | 59.44 | 0.00 | 0.00 |
| March | 0.144720E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604146.5 | 59.44 | 0.00 | 0.00 |
| April | 0.136199E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178747788.8 | 59.44 | 0.00 | 0.00 |
| May | 0.133881E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177583385.9 | 59.44 | 0.00 | 0.00 |
| June | 0.122638E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168737635.7 | 59.44 | 0.00 | 0.00 |
| July | 0.120948E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173340725.3 | 59.44 | 0.00 | 0.00 |
| August | 0.118015E+10 | -0.100591E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174241579.7 | 59.44 | 0.00 | 0.00 |
| September | 0.115297E+10 | -978627150.6 | 0.00 | 0.00 | 720.00 | 0.00 | -174347109.4 | 59.44 | 0.00 | 0.00 |
| October | 0.123601E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185780885.3 | 59.44 | 0.00 | 0.00 |
| November | 0.125677E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180547949.3 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602560.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155124E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214168E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115297E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144720E+10 | -978627150.6 | 0.00 | 0.00 | 744.00 | 0.00 | -168546213.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546213.0 | 59.44 | 0.00 | 0.00 |
| March | 0.144719E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186596535.0 | 59.44 | 0.00 | 0.00 |
| April | 0.136238E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179130133.1 | 59.44 | 0.00 | 0.00 |
| May | 0.133869E+10 | -0.116123E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177463898.3 | 59.44 | 0.00 | 0.00 |
| June | 0.122599E+10 | -0.105764E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168346947.8 | 59.44 | 0.00 | 0.00 |
| July | 0.120916E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173029177.3 | 59.44 | 0.00 | 0.00 |
| August | 0.117959E+10 | -0.100590E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173689213.6 | 59.44 | 0.00 | 0.00 |
| September | 0.115262E+10 | -978625582.0 | 0.00 | 0.00 | 720.00 | 0.00 | -173991379.4 | 59.44 | 0.00 | 0.00 |
| October | 0.123602E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185789525.1 | 59.44 | 0.00 | 0.00 |
| November | 0.125675E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180530451.8 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601294.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155110E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214032E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115262E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144719E+10 | -978625582.0 | 0.00 | 0.00 | 744.00 | 0.00 | -168346947.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142399E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| February | 0.131170E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168546213.0 | 59.44 | 0.00 | 0.00 |
| March | 0.144719E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186599969.4 | 59.44 | 0.00 | 0.00 |
| April | 0.136236E+10 | -0.118325E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179113059.6 | 59.44 | 0.00 | 0.00 |
| May | 0.133866E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177436640.0 | 59.44 | 0.00 | 0.00 |
| June | 0.122598E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168332465.4 | 59.44 | 0.00 | 0.00 |
| July | 0.120917E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173037322.2 | 59.44 | 0.00 | 0.00 |
| August | 0.117959E+10 | -0.100590E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173687627.0 | 59.44 | 0.00 | 0.00 |
| September | 0.115258E+10 | -978624973.2 | 0.00 | 0.00 | 720.00 | 0.00 | -173957118.8 | 59.44 | 0.00 | 0.00 |
| October | 0.123603E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185790951.3 | 59.44 | 0.00 | 0.00 |
| November | 0.125675E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180529680.3 | 59.44 | 0.00 | 0.00 |
| December | 0.136692E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602290.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155109E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214024E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115258E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604571.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144719E+10 | -978624973.2 | 0.00 | 0.00 | 744.00 | 0.00 | -168332465.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142398E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186594168.0 | 59.44 | 0.00 | 0.00 |
| February | 0.131118E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168023062.5 | 59.44 | 0.00 | 0.00 |
| March | 0.144599E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185394076.9 | 59.44 | 0.00 | 0.00 |
| April | 0.136007E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176829561.8 | 59.44 | 0.00 | 0.00 |
| May | 0.133778E+10 | -0.116122E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176554280.0 | 59.44 | 0.00 | 0.00 |
| June | 0.122602E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168376465.7 | 59.44 | 0.00 | 0.00 |
| July | 0.120917E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173037718.6 | 59.44 | 0.00 | 0.00 |
| August | 0.117940E+10 | -0.100590E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173496921.2 | 59.44 | 0.00 | 0.00 |
| September | 0.115076E+10 | -978625339.2 | 0.00 | 0.00 | 720.00 | 0.00 | -172137107.9 | 59.44 | 0.00 | 0.00 |
| October | 0.123401E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183777846.0 | 59.44 | 0.00 | 0.00 |
| November | 0.125638E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180159981.4 | 59.44 | 0.00 | 0.00 |
| December | 0.136693E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601854.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155017E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213098E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115076E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186601854.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144599E+10 | -978625339.2 | 0.00 | 0.00 | 744.00 | 0.00 | -168023062.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.142398E+10 | -0.123738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186594143.1 | 59.44 | 0.00 | 0.00 |
| February | 0.131118E+10 | -0.114315E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168026136.4 | 59.44 | 0.00 | 0.00 |
| March | 0.144599E+10 | -0.126059E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185393118.1 | 59.44 | 0.00 | 0.00 |
| April | 0.136005E+10 | -0.118324E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176809444.5 | 59.44 | 0.00 | 0.00 |
| May | 0.133777E+10 | -0.116123E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176548091.7 | 59.44 | 0.00 | 0.00 |
| June | 0.122601E+10 | -0.105765E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168364292.6 | 59.44 | 0.00 | 0.00 |
| July | 0.120918E+10 | -0.103613E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173042672.7 | 59.44 | 0.00 | 0.00 |
| August | 0.117940E+10 | -0.100590E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173499004.6 | 59.44 | 0.00 | 0.00 |
| September | 0.115077E+10 | -978625359.1 | 0.00 | 0.00 | 720.00 | 0.00 | -172141522.1 | 59.44 | 0.00 | 0.00 |
| October | 0.123402E+10 | -0.105023E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183787281.6 | 59.44 | 0.00 | 0.00 |
| November | 0.125638E+10 | -0.107622E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180158006.9 | 59.44 | 0.00 | 0.00 |
| December | 0.136693E+10 | -0.118032E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601883.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.155016E+11 | -0.133707E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213097E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.115077E+10 | -0.126059E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186601883.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.144599E+10 | -978625359.1 | 0.00 | 0.00 | 744.00 | 0.00 | -168026136.4 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 243.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 265.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 254.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 296.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 401.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 409.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 352.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 344.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 255.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 3785.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.614518E+10 | 3969.06 | 09-JAN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.436991E+10 | 3428.53 | 14-FEB-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.375260E+10 | 3163.36 | 05-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.162545E+10 | 2030.73 | 04-APR-07:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.148046E+09 | 1134.94 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 37298.62 | 33.32 | 04-JUN-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.733571E+09 | 1478.44 | 30-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.264750E+10 | 2584.81 | 25-NOV-08:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.576278E+10 | 3900.32 | 24-DEC-08:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.251851E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.614518E+10 | 3969.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.716858E+10 | 4245.40 | 05-JAN-08:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.539712E+10 | 3813.68 | 14-FEB-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.473502E+10 | 3357.37 | 15-MAR-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.226479E+10 | 2161.51 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.268213E+09 | 1292.65 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 321794.63 | 55.97 | 04-JUN-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 10815169.58 | 185.21 | 29-SEP-02:70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.111520E+10 | 1606.56 | 30-OCT-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.323632E+10 | 2662.10 | 25-NOV-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.653996E+10 | 4078.80 | 24-DEC-08:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.307363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.716858E+10 | 4245.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.487076E+10 | 11312.08 | 03-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.301020E+10 | 11312.08 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.221263E+10 | 11312.08 | 01-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.427440E+09 | 11312.08 | 03-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 13293148.71 | 11312.08 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.128951E+09 | 11312.08 | 12-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113831E+10 | 11312.08 | 03-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.422694E+10 | 11312.08 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.160285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.487076E+10 | 11312.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.716162E+10 | 4218.21 | 05-JAN-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.540056E+10 | 3727.97 | 14-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.473231E+10 | 3244.64 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.221085E+10 | 2206.75 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.264318E+09 | 1273.90 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 14397712.74 | 212.49 | 29-SEP-02:70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.113112E+10 | 1617.44 | 30-OCT-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.323288E+10 | 2643.36 | 25-NOV-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.653000E+10 | 4033.29 | 24-DEC-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.306781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.716162E+10 | 4218.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.548847E+10 | 3289.33 | 05-JAN-08:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.410697E+10 | 2975.91 | 14-FEB-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.360276E+10 | 2590.58 | 15-MAR-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.162979E+10 | 1653.00 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.175965E+09 | 940.56 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.715646E+09 | 1149.75 | 30-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.234209E+10 | 2005.86 | 25-NOV-08:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.496523E+10 | 3126.05 | 24-DEC-08:27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230269E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.548847E+10 | 3289.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.548819E+10 | 3289.34 | 05-JAN-08:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.410743E+10 | 2976.25 | 14-FEB-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.360283E+10 | 2588.92 | 15-MAR-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.162856E+10 | 1654.75 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.176421E+09 | 938.75 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.717788E+09 | 1150.68 | 30-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.234185E+10 | 2005.47 | 25-NOV-08:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.496488E+10 | 3125.95 | 24-DEC-08:27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230280E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.548819E+10 | 3289.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.447899E+10 | 3040.05 | 09-JAN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.310377E+10 | 2584.19 | 14-FEB-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.263810E+10 | 2380.11 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.101453E+10 | 1425.38 | 04-APR-07:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 69895202.98 | 786.13 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.393377E+09 | 1015.23 | 30-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.178035E+10 | 1929.94 | 25-NOV-08:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.420266E+10 | 2957.43 | 24-DEC-08:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.176817E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.447899E+10 | 3040.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.481312E+10 | 3221.81 | 09-JAN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.336443E+10 | 2733.25 | 14-FEB-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.288111E+10 | 2539.12 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.110999E+10 | 1544.55 | 04-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 74479692.29 | 869.22 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.425951E+09 | 1064.74 | 30-OCT-07:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.197751E+10 | 2072.44 | 25-NOV-08:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.451723E+10 | 3129.18 | 24-DEC-08:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.191638E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.481312E+10 | 3221.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.101875E+11 | 7552.81 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.669140E+10 | 6190.57 | 13-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.459055E+10 | 5428.85 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134716E+10 | 2974.19 | 04-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 14619577.65 | 833.80 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.121809E+10 | 2893.65 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.455743E+10 | 5108.31 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.100244E+11 | 7140.88 | 24-DEC-08:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.386311E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.101875E+11 | 7552.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.122108E+11 | 8170.72 | 04-JAN-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.871709E+10 | 6731.14 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.640597E+10 | 5718.51 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.211034E+10 | 3263.93 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 45220368.68 | 1403.83 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.179105E+10 | 3053.04 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.573637E+10 | 5143.18 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.115714E+11 | 7595.25 | 24-DEC-08:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.485882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.122108E+11 | 8170.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.101676E+11 | 7547.19 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.667911E+10 | 6213.57 | 13-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.456464E+10 | 5416.07 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129070E+10 | 2995.04 | 04-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 7392579.99 | 727.14 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.122634E+10 | 2908.61 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.454579E+10 | 5099.18 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.999745E+10 | 7134.44 | 24-DEC-08:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.384790E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.101676E+11 | 7547.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.121935E+11 | 7920.09 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.871551E+10 | 6811.20 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.638238E+10 | 5742.87 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.200403E+10 | 3355.85 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 35127736.21 | 1344.06 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.181418E+10 | 3068.05 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.572913E+10 | 5134.73 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.115460E+11 | 7366.04 | 24-DEC-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.484198E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.121935E+11 | 7920.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.875898E+10 | 5689.19 | 04-JAN-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.623399E+10 | 4968.46 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.461548E+10 | 4111.32 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.130555E+10 | 2433.26 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 26697799.06 | 874.70 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.926351E+09 | 2043.93 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.376628E+10 | 3617.51 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.817591E+10 | 5381.07 | 24-DEC-08:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.338092E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.875898E+10 | 5689.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.875849E+10 | 5682.14 | 04-JAN-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.623481E+10 | 4972.92 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.461660E+10 | 4112.24 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.130357E+10 | 2436.55 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 25874682.73 | 862.56 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.929346E+09 | 2044.64 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.376569E+10 | 3617.24 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.817508E+10 | 5377.38 | 24-DEC-08:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.338095E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.875849E+10 | 5682.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.678851E+10 | 5136.43 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.426615E+10 | 4387.94 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.282225E+10 | 3918.95 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.640509E+09 | 2044.97 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 1110383.07 | 174.06 | 01-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.495913E+09 | 1902.91 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.262425E+10 | 3569.17 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.667688E+10 | 4985.47 | 24-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.243156E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.678851E+10 | 5136.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.678770E+10 | 5136.14 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.426769E+10 | 4391.47 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.282346E+10 | 3918.89 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.639858E+09 | 2049.30 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 869982.80 | 152.31 | 01-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.496669E+09 | 1904.03 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.262441E+10 | 3568.84 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.667590E+10 | 4985.81 | 24-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.243166E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.678770E+10 | 5136.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.782277E+10 | 5615.95 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.543523E+10 | 4850.85 | 14-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.411360E+10 | 4151.73 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.178085E+10 | 2560.73 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.207276E+09 | 1269.11 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 9026996.03 | 625.32 | 04-JUN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 10550804.09 | 615.01 | 19-AUG-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.253854E+09 | 891.08 | 28-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.168450E+10 | 2578.25 | 30-OCT-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.394662E+10 | 3815.40 | 25-NOV-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.764614E+10 | 5286.19 | 24-DEC-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.329104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.782277E+10 | 5615.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.889490E+10 | 5702.83 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.650791E+10 | 4991.14 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.502111E+10 | 4313.94 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.219942E+10 | 2738.47 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.242489E+09 | 1426.57 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 8223407.89 | 562.18 | 04-JUN-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 11924917.77 | 606.46 | 19-AUG-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.336869E+09 | 971.48 | 23-SEP-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.204783E+10 | 2596.16 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.457772E+10 | 3825.54 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.846697E+10 | 5510.46 | 24-DEC-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.383154E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.889490E+10 | 5702.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.781217E+10 | 5609.42 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.541923E+10 | 4869.18 | 14-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.408022E+10 | 4152.23 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.171285E+10 | 2617.52 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.193005E+09 | 1269.29 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 7126925.06 | 513.01 | 04-JUN-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 8280710.92 | 565.48 | 19-AUG-05:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.255748E+09 | 903.30 | 28-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.169151E+10 | 2587.48 | 30-OCT-07:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.394008E+10 | 3807.73 | 25-NOV-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.763009E+10 | 5276.34 | 24-DEC-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.327503E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.781217E+10 | 5609.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.888646E+10 | 5696.51 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.650189E+10 | 5012.40 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.500422E+10 | 4326.45 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.211322E+10 | 2795.55 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.229052E+09 | 1434.93 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 6885958.45 | 507.63 | 04-JUN-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 9346581.25 | 594.10 | 19-AUG-05:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.330846E+09 | 943.05 | 23-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.205396E+10 | 2605.48 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.457236E+10 | 3818.35 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.845229E+10 | 5367.15 | 24-DEC-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.381605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.888646E+10 | 5696.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.672956E+10 | 4182.16 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.491180E+10 | 3821.74 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.382322E+10 | 3216.26 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.155931E+10 | 2109.09 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.126586E+09 | 1044.34 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 1634182.06 | 230.20 | 04-JUN-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 2332866.35 | 256.91 | 19-AUG-05:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.160053E+09 | 628.66 | 23-SEP-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.138909E+10 | 1905.38 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.330797E+10 | 2853.78 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.634015E+10 | 4094.08 | 24-DEC-08:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.283517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.672956E+10 | 4182.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.672951E+10 | 4182.27 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.491248E+10 | 3823.54 | 14-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.382471E+10 | 3217.32 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.155806E+10 | 2113.20 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.127409E+09 | 1042.38 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 1470660.09 | 217.95 | 04-JUN-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 2257862.80 | 253.91 | 19-AUG-05:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.160948E+09 | 631.98 | 23-SEP-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.139184E+10 | 1905.58 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.330793E+10 | 2853.41 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.633977E+10 | 4089.77 | 24-DEC-08:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.283564E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.672951E+10 | 4182.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.565857E+10 | 4088.71 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.384949E+10 | 3656.27 | 14-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.290793E+10 | 3180.58 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.115012E+10 | 1912.51 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 93280190.80 | 888.03 | 01-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 2314240.24 | 306.06 | 04-JUN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 1909207.29 | 249.20 | 19-AUG-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.103783E+09 | 550.06 | 28-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.105830E+10 | 1892.20 | 30-OCT-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.269490E+10 | 2841.30 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.551977E+10 | 3911.62 | 24-DEC-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.565857E+10 | 4088.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.565846E+10 | 4088.82 | 04-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.385056E+10 | 3658.19 | 14-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.290934E+10 | 3180.44 | 05-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.114970E+10 | 1916.53 | 05-APR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 94053609.21 | 884.89 | 01-MAY-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 2130322.01 | 295.01 | 04-JUN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 1862835.37 | 245.85 | 19-AUG-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.104779E+09 | 551.85 | 28-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.106023E+10 | 1892.51 | 30-OCT-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.269523E+10 | 2841.17 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.551930E+10 | 3911.53 | 24-DEC-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230456E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.565846E+10 | 4088.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 14908821.17 | 13883445.36 | 934.32 | 23-APR-16:10 | 868.28 | 0.00 |
| May | 0.00 | 0.00 | 0.436846E+09 | 0.410031E+09 | 2002.00 | 25-MAY-17:40 | 1805.06 | 0.00 |
| June | 0.00 | 0.00 | 0.134267E+10 | 0.110316E+10 | 3245.63 | 30-JUN-16:02 | 2510.60 | 0.00 |
| July | 0.00 | 0.00 | 0.266573E+10 | 0.216813E+10 | 3127.88 | 23-JUL-16:05 | 2527.33 | 0.00 |
| August | 0.00 | 0.00 | 0.215856E+10 | 0.181405E+10 | 2989.69 | 08-AUG-16:04 | 2397.67 | 0.00 |
| September | 0.00 | 0.00 | 0.726915E+09 | 0.682057E+09 | 2527.98 | 01-SEP-16:04 | 2364.28 | 0.00 |
| October | 0.00 | 0.00 | 76384713.66 | 76081508.62 | 1282.27 | 22-OCT-15:30 | 1282.27 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.742202E+10 | 0.626740E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.266573E+10 | 0.216813E+10 | 3245.63 | 2527.33 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.253586E+09 | 0.232123E+09 | 1737.72 | 25-MAY-18:00 | 1535.56 | 0.00 |
| June | 0.00 | 0.00 | 0.110155E+10 | 0.878178E+09 | 2930.85 | 29-JUN-16:30 | 2303.79 | 0.00 |
| July | 0.00 | 0.00 | 0.219109E+10 | 0.174121E+10 | 2579.74 | 23-JUL-16:30 | 2028.45 | 0.00 |
| August | 0.00 | 0.00 | 0.148859E+10 | 0.121147E+10 | 2544.14 | 08-AUG-16:30 | 1956.00 | 0.00 |
| September | 0.00 | 0.00 | 0.215080E+09 | 0.191797E+09 | 1733.47 | 01-SEP-16:15 | 1562.20 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.524990E+10 | 0.425479E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.219109E+10 | 0.174121E+10 | 2930.85 | 2303.79 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 9392602.47 | 9392602.47 | 404.15 | 13-APR-15:00 | 404.15 | 0.00 |
| May | 0.00 | 0.00 | 0.564922E+09 | 0.529658E+09 | 7020.88 | 26-MAY-08:62 | 5782.90 | 0.00 |
| June | 0.00 | 0.00 | 0.150721E+10 | 0.130672E+10 | 7630.96 | 30-JUN-07:02 | 4643.85 | 0.00 |
| July | 0.00 | 0.00 | 0.207444E+10 | 0.178790E+10 | 7472.61 | 05-JUL-07:02 | 4938.44 | 0.00 |
| August | 0.00 | 0.00 | 0.197985E+10 | 0.168181E+10 | 7323.83 | 09-AUG-07:03 | 5342.33 | 0.00 |
| September | 0.00 | 0.00 | 0.775841E+09 | 0.734746E+09 | 7219.45 | 01-SEP-07:02 | 5268.87 | 0.00 |
| October | 0.00 | 0.00 | 0.101445E+09 | 0.101097E+09 | 1547.60 | 20-OCT-14:30 | 1547.60 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.701311E+10 | 0.615132E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.207444E+10 | 0.178790E+10 | 7630.96 | 5782.90 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.223841E+09 | 0.204492E+09 | 1223.77 | 25-MAY-18:00 | 1056.90 | 0.00 |
| June | 0.00 | 0.00 | 0.115275E+10 | 0.925639E+09 | 2535.95 | 29-JUN-16:02 | 1953.82 | 0.00 |
| July | 0.00 | 0.00 | 0.220924E+10 | 0.175668E+10 | 2414.40 | 15-JUL-15:10 | 1640.86 | 0.00 |
| August | 0.00 | 0.00 | 0.145573E+10 | 0.118226E+10 | 2234.58 | 08-AUG-16:04 | 1692.76 | 0.00 |
| September | 0.00 | 0.00 | 0.207019E+09 | 0.184324E+09 | 1406.07 | 01-SEP-16:04 | 1261.38 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.524858E+10 | 0.425339E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.220924E+10 | 0.175668E+10 | 2535.95 | 1953.82 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.199911E+09 | 0.180780E+09 | 1175.34 | 25-MAY-18:00 | 1011.58 | 0.00 |
| June | 0.00 | 0.00 | 0.970429E+09 | 0.758474E+09 | 2174.50 | 29-JUN-16:02 | 1655.79 | 0.00 |
| July | 0.00 | 0.00 | 0.185006E+10 | 0.144332E+10 | 2051.16 | 15-JUL-15:10 | 1380.60 | 0.00 |
| August | 0.00 | 0.00 | 0.126083E+10 | 0.100809E+10 | 1852.59 | 08-AUG-16:04 | 1380.15 | 0.00 |
| September | 0.00 | 0.00 | 0.172565E+09 | 0.149130E+09 | 1194.06 | 01-SEP-16:08 | 1058.72 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.445379E+10 | 0.353979E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.185006E+10 | 0.144332E+10 | 2174.50 | 1655.79 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.197798E+09 | 0.178869E+09 | 1160.15 | 25-MAY-18:00 | 997.76 | 0.00 |
| June | 0.00 | 0.00 | 0.977955E+09 | 0.765566E+09 | 2168.95 | 29-JUN-16:02 | 1651.47 | 0.00 |
| July | 0.00 | 0.00 | 0.184996E+10 | 0.144327E+10 | 2050.88 | 15-JUL-15:10 | 1381.00 | 0.00 |
| August | 0.00 | 0.00 | 0.126052E+10 | 0.100791E+10 | 1847.65 | 08-AUG-16:04 | 1376.45 | 0.00 |
| September | 0.00 | 0.00 | 0.173518E+09 | 0.150031E+09 | 1189.46 | 01-SEP-16:08 | 1054.77 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.445974E+10 | 0.354564E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.184996E+10 | 0.144327E+10 | 2168.95 | 1651.47 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 8836426.41 | 8185554.58 | 577.68 | 23-APR-16:03 | 534.70 | 0.00 |
| May | 0.00 | 0.00 | 0.387786E+09 | 0.361731E+09 | 1472.88 | 25-MAY-15:10 | 1291.65 | 0.00 |
| June | 0.00 | 0.00 | 0.123401E+10 | 0.100282E+10 | 2516.47 | 30-JUN-15:10 | 1932.22 | 0.00 |
| July | 0.00 | 0.00 | 0.234936E+10 | 0.188810E+10 | 2441.71 | 23-JUL-13:30 | 1933.53 | 0.00 |
| August | 0.00 | 0.00 | 0.196883E+10 | 0.164043E+10 | 2324.43 | 08-AUG-15:10 | 1836.45 | 0.00 |
| September | 0.00 | 0.00 | 0.748821E+09 | 0.698662E+09 | 2031.70 | 01-SEP-15:10 | 1864.05 | 0.00 |
| October | 0.00 | 0.00 | 89325360.03 | 88901713.47 | 1212.10 | 22-OCT-14:00 | 1198.92 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.678697E+10 | 0.568883E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.234936E+10 | 0.188810E+10 | 2516.47 | 1933.53 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 8523722.91 | 7892725.09 | 566.40 | 23-APR-16:10 | 523.73 | 0.00 |
| May | 0.00 | 0.00 | 0.425829E+09 | 0.397732E+09 | 1523.32 | 25-MAY-15:10 | 1340.00 | 0.00 |
| June | 0.00 | 0.00 | 0.136163E+10 | 0.111489E+10 | 2597.06 | 30-JUN-15:10 | 2007.17 | 0.00 |
| July | 0.00 | 0.00 | 0.258942E+10 | 0.209871E+10 | 2603.05 | 23-JUL-13:30 | 2086.92 | 0.00 |
| August | 0.00 | 0.00 | 0.217841E+10 | 0.182571E+10 | 2400.75 | 08-AUG-15:10 | 1907.61 | 0.00 |
| September | 0.00 | 0.00 | 0.841661E+09 | 0.786742E+09 | 2098.87 | 01-SEP-15:10 | 1930.49 | 0.00 |
| October | 0.00 | 0.00 | 95327687.34 | 94888506.26 | 1254.60 | 22-OCT-14:00 | 1241.21 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.750079E+10 | 0.632656E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.258942E+10 | 0.209871E+10 | 2603.05 | 2086.92 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 1271940.30 | 1271940.30 | 332.55 | 19-MAR-16:30 | 332.55 | 0.00 |
| April | 0.00 | 0.00 | 0.498933E+09 | 0.493157E+09 | 5665.86 | 23-APR-16:10 | 5408.73 | 0.00 |
| May | 0.00 | 0.00 | 0.307263E+10 | 0.297398E+10 | 6321.65 | 25-MAY-17:30 | 5861.76 | 0.00 |
| June | 0.00 | 0.00 | 0.525496E+10 | 0.454742E+10 | 8440.91 | 30-JUN-16:02 | 6699.70 | 0.00 |
| July | 0.00 | 0.00 | 0.729309E+10 | 0.607087E+10 | 7881.94 | 23-JUL-16:05 | 6489.68 | 0.00 |
| August | 0.00 | 0.00 | 0.553056E+10 | 0.471226E+10 | 7466.45 | 08-AUG-16:04 | 6091.35 | 0.00 |
| September | 0.00 | 0.00 | 0.213613E+10 | 0.201560E+10 | 6646.09 | 01-SEP-15:30 | 6236.61 | 0.00 |
| October | 0.00 | 0.00 | 0.457782E+09 | 0.456672E+09 | 4201.83 | 22-OCT-15:30 | 4201.83 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.242454E+11 | 0.212712E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.729309E+10 | 0.607087E+10 | 8440.91 | 6699.70 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 56463819.62 | 53480067.99 | 3036.27 | 23-APR-17:30 | 2858.35 | 0.00 |
| May | 0.00 | 0.00 | 0.216589E+10 | 0.207110E+10 | 5933.64 | 25-MAY-18:00 | 5455.57 | 0.00 |
| June | 0.00 | 0.00 | 0.465590E+10 | 0.396924E+10 | 7784.28 | 29-JUN-16:13 | 6280.06 | 0.00 |
| July | 0.00 | 0.00 | 0.629160E+10 | 0.514452E+10 | 6621.44 | 15-JUL-14:30 | 4553.48 | 0.00 |
| August | 0.00 | 0.00 | 0.411460E+10 | 0.341212E+10 | 6433.70 | 08-AUG-16:12 | 5045.10 | 0.00 |
| September | 0.00 | 0.00 | 0.772031E+09 | 0.693164E+09 | 4520.95 | 01-SEP-16:12 | 4134.25 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.180565E+11 | 0.153436E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.629160E+10 | 0.514452E+10 | 7784.28 | 6280.06 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.474887E+09 | 0.469946E+09 | 4136.76 | 23-APR-16:10 | 3925.03 | 0.00 |
| May | 0.00 | 0.00 | 0.293859E+10 | 0.284156E+10 | 5513.16 | 18-MAY-13:00 | 5476.10 | 0.00 |
| June | 0.00 | 0.00 | 0.545927E+10 | 0.474541E+10 | 7415.70 | 30-JUN-15:10 | 5838.56 | 0.00 |
| July | 0.00 | 0.00 | 0.734564E+10 | 0.611412E+10 | 7175.57 | 23-JUL-13:30 | 5959.34 | 0.00 |
| August | 0.00 | 0.00 | 0.546655E+10 | 0.465031E+10 | 6676.63 | 08-AUG-14:10 | 5428.46 | 0.00 |
| September | 0.00 | 0.00 | 0.213840E+10 | 0.202162E+10 | 6044.55 | 01-SEP-12:40 | 5350.53 | 0.00 |
| October | 0.00 | 0.00 | 0.442611E+09 | 0.441224E+09 | 4014.75 | 22-OCT-13:30 | 3952.46 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.242659E+11 | 0.212842E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.734564E+10 | 0.611412E+10 | 7415.70 | 5959.34 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 29020309.57 | 27201145.02 | 1546.22 | 23-APR-18:00 | 1432.42 | 0.00 |
| May | 0.00 | 0.00 | 0.201135E+10 | 0.191861E+10 | 4149.30 | 25-MAY-18:00 | 3730.91 | 0.00 |
| June | 0.00 | 0.00 | 0.486184E+10 | 0.416832E+10 | 6385.93 | 29-JUN-16:02 | 5035.20 | 0.00 |
| July | 0.00 | 0.00 | 0.634609E+10 | 0.518947E+10 | 5993.95 | 15-JUL-14:30 | 4094.82 | 0.00 |
| August | 0.00 | 0.00 | 0.404858E+10 | 0.334887E+10 | 5396.30 | 08-AUG-16:04 | 4144.17 | 0.00 |
| September | 0.00 | 0.00 | 0.754166E+09 | 0.678143E+09 | 3564.81 | 01-SEP-11:00 | 2872.02 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.180510E+11 | 0.153306E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.634609E+10 | 0.518947E+10 | 6385.93 | 5035.20 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 17595638.90 | 16383370.44 | 1129.93 | 23-APR-18:00 | 1040.35 | 0.00 |
| May | 0.00 | 0.00 | 0.160145E+10 | 0.151931E+10 | 3640.42 | 25-MAY-18:00 | 3245.59 | 0.00 |
| June | 0.00 | 0.00 | 0.378975E+10 | 0.317785E+10 | 5217.70 | 29-JUN-16:02 | 4061.97 | 0.00 |
| July | 0.00 | 0.00 | 0.499601E+10 | 0.399865E+10 | 4876.39 | 15-JUL-15:10 | 3357.97 | 0.00 |
| August | 0.00 | 0.00 | 0.337224E+10 | 0.274563E+10 | 4313.24 | 08-AUG-16:04 | 3258.44 | 0.00 |
| September | 0.00 | 0.00 | 0.656342E+09 | 0.573222E+09 | 2755.13 | 01-SEP-16:08 | 2464.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.144334E+11 | 0.120310E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.499601E+10 | 0.399865E+10 | 5217.70 | 4061.97 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 17171125.32 | 15981591.67 | 1105.33 | 23-APR-18:00 | 1017.41 | 0.00 |
| May | 0.00 | 0.00 | 0.159940E+10 | 0.151740E+10 | 3604.39 | 25-MAY-18:00 | 3211.71 | 0.00 |
| June | 0.00 | 0.00 | 0.379949E+10 | 0.318750E+10 | 5198.99 | 29-JUN-16:02 | 4046.44 | 0.00 |
| July | 0.00 | 0.00 | 0.499723E+10 | 0.399989E+10 | 4869.43 | 15-JUL-15:10 | 3353.36 | 0.00 |
| August | 0.00 | 0.00 | 0.337115E+10 | 0.274491E+10 | 4301.03 | 08-AUG-16:04 | 3249.23 | 0.00 |
| September | 0.00 | 0.00 | 0.660240E+09 | 0.577151E+09 | 2742.42 | 01-SEP-16:08 | 2452.91 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.144447E+11 | 0.120428E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.499723E+10 | 0.399989E+10 | 5198.99 | 4046.44 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.381937E+09 | 0.377292E+09 | 3816.41 | 23-APR-16:10 | 3627.03 | 0.00 |
| May | 0.00 | 0.00 | 0.249511E+10 | 0.240782E+10 | 4446.68 | 18-MAY-13:40 | 4430.69 | 0.00 |
| June | 0.00 | 0.00 | 0.439393E+10 | 0.375757E+10 | 6086.28 | 30-JUN-15:10 | 4773.21 | 0.00 |
| July | 0.00 | 0.00 | 0.601177E+10 | 0.492750E+10 | 5916.46 | 23-JUL-13:30 | 4811.24 | 0.00 |
| August | 0.00 | 0.00 | 0.481417E+10 | 0.405997E+10 | 5501.54 | 08-AUG-15:10 | 4418.34 | 0.00 |
| September | 0.00 | 0.00 | 0.212307E+10 | 0.199434E+10 | 5182.68 | 01-SEP-13:30 | 4673.41 | 0.00 |
| October | 0.00 | 0.00 | 0.514618E+09 | 0.513251E+09 | 3946.22 | 22-OCT-13:40 | 3892.92 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.207346E+11 | 0.180377E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.601177E+10 | 0.492750E+10 | 6086.28 | 4811.24 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.389410E+09 | 0.384783E+09 | 3796.15 | 23-APR-16:10 | 3607.53 | 0.00 |
| May | 0.00 | 0.00 | 0.249489E+10 | 0.240772E+10 | 4460.30 | 18-MAY-13:30 | 4439.56 | 0.00 |
| June | 0.00 | 0.00 | 0.440385E+10 | 0.376743E+10 | 6074.28 | 30-JUN-15:10 | 4763.46 | 0.00 |
| July | 0.00 | 0.00 | 0.601326E+10 | 0.492906E+10 | 5927.89 | 23-JUL-13:30 | 4823.20 | 0.00 |
| August | 0.00 | 0.00 | 0.481301E+10 | 0.405922E+10 | 5499.85 | 08-AUG-14:10 | 4434.62 | 0.00 |
| September | 0.00 | 0.00 | 0.212481E+10 | 0.199626E+10 | 5197.92 | 01-SEP-13:30 | 4689.00 | 0.00 |
| October | 0.00 | 0.00 | 0.513945E+09 | 0.512570E+09 | 3956.22 | 22-OCT-13:40 | 3902.92 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.207532E+11 | 0.180570E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.601326E+10 | 0.492906E+10 | 6074.28 | 4823.20 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 2508428.87 | 2508428.87 | 441.86 | 28-FEB-15:30 | 441.86 | 0.00 |
| March | 0.00 | 0.00 | 44870784.90 | 44870784.90 | 1328.88 | 26-MAR-16:06 | 1328.88 | 0.00 |
| April | 0.00 | 0.00 | 0.371069E+09 | 0.367867E+09 | 3542.91 | 23-APR-16:10 | 3391.63 | 0.00 |
| May | 0.00 | 0.00 | 0.151775E+10 | 0.147150E+10 | 3989.84 | 25-MAY-16:12 | 3714.25 | 0.00 |
| June | 0.00 | 0.00 | 0.258148E+10 | 0.224788E+10 | 5342.22 | 30-JUN-16:02 | 4338.35 | 0.00 |
| July | 0.00 | 0.00 | 0.360793E+10 | 0.302909E+10 | 4993.31 | 23-JUL-16:05 | 4192.69 | 0.00 |
| August | 0.00 | 0.00 | 0.258014E+10 | 0.222064E+10 | 4830.51 | 08-AUG-15:30 | 4010.70 | 0.00 |
| September | 0.00 | 0.00 | 0.885893E+09 | 0.843090E+09 | 4310.66 | 01-SEP-15:30 | 4084.77 | 0.00 |
| October | 0.00 | 0.00 | 0.258766E+09 | 0.258378E+09 | 2516.93 | 19-OCT-15:10 | 2516.93 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.118504E+11 | 0.104858E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.360793E+10 | 0.302909E+10 | 5342.22 | 4338.35 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 75711695.42 | 73609332.99 | 2391.66 | 23-APR-17:15 | 2274.84 | 0.00 |
| May | 0.00 | 0.00 | 0.107334E+10 | 0.102846E+10 | 3740.00 | 25-MAY-18:00 | 3483.79 | 0.00 |
| June | 0.00 | 0.00 | 0.225666E+10 | 0.192982E+10 | 4961.61 | 29-JUN-16:13 | 4091.22 | 0.00 |
| July | 0.00 | 0.00 | 0.307792E+10 | 0.253153E+10 | 4234.68 | 23-JUL-16:30 | 3483.56 | 0.00 |
| August | 0.00 | 0.00 | 0.186981E+10 | 0.156295E+10 | 4157.61 | 08-AUG-16:12 | 3345.02 | 0.00 |
| September | 0.00 | 0.00 | 0.277310E+09 | 0.250623E+09 | 2933.42 | 01-SEP-16:15 | 2716.75 | 0.00 |
| October | 0.00 | 0.00 | 3998690.03 | 3998690.03 | 461.62 | 19-OCT-16:10 | 461.62 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.863474E+10 | 0.738099E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.307792E+10 | 0.253153E+10 | 4961.61 | 4091.22 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 15383800.66 | 15383800.66 | 664.07 | 26-MAR-15:10 | 664.07 | 0.00 |
| April | 0.00 | 0.00 | 0.323740E+09 | 0.321043E+09 | 2510.43 | 23-APR-15:30 | 2404.48 | 0.00 |
| May | 0.00 | 0.00 | 0.140709E+10 | 0.136119E+10 | 3601.17 | 18-MAY-13:30 | 3591.62 | 0.00 |
| June | 0.00 | 0.00 | 0.264360E+10 | 0.230521E+10 | 4781.21 | 30-JUN-13:20 | 3898.94 | 0.00 |
| July | 0.00 | 0.00 | 0.363800E+10 | 0.304980E+10 | 4640.46 | 23-JUL-13:30 | 3954.60 | 0.00 |
| August | 0.00 | 0.00 | 0.252896E+10 | 0.216988E+10 | 4341.53 | 08-AUG-14:10 | 3606.56 | 0.00 |
| September | 0.00 | 0.00 | 0.871776E+09 | 0.830642E+09 | 3939.62 | 01-SEP-12:40 | 3531.80 | 0.00 |
| October | 0.00 | 0.00 | 0.250583E+09 | 0.250012E+09 | 2280.38 | 22-OCT-13:40 | 2254.09 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.116791E+11 | 0.103032E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.363800E+10 | 0.304980E+10 | 4781.21 | 3954.60 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 28707678.52 | 27249215.30 | 1296.03 | 23-APR-16:15 | 1219.60 | 0.00 |
| May | 0.00 | 0.00 | 0.948344E+09 | 0.903916E+09 | 2520.73 | 25-MAY-16:05 | 2266.06 | 0.00 |
| June | 0.00 | 0.00 | 0.232317E+10 | 0.199050E+10 | 3989.80 | 29-JUN-16:02 | 3208.58 | 0.00 |
| July | 0.00 | 0.00 | 0.311829E+10 | 0.256071E+10 | 3669.90 | 15-JUL-14:40 | 2551.36 | 0.00 |
| August | 0.00 | 0.00 | 0.181044E+10 | 0.150456E+10 | 3382.45 | 08-AUG-16:04 | 2654.16 | 0.00 |
| September | 0.00 | 0.00 | 0.225191E+09 | 0.200219E+09 | 2215.03 | 01-SEP-11:00 | 1792.51 | 0.00 |
| October | 0.00 | 0.00 | 94986.47 | 94986.47 | 64.15 | 19-OCT-16:05 | 64.15 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.845425E+10 | 0.718724E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.311829E+10 | 0.256071E+10 | 3989.80 | 3208.58 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 21953972.77 | 20728803.49 | 1091.01 | 23-APR-18:00 | 1018.72 | 0.00 |
| May | 0.00 | 0.00 | 0.720251E+09 | 0.680834E+09 | 2267.29 | 25-MAY-18:00 | 2054.26 | 0.00 |
| June | 0.00 | 0.00 | 0.176656E+10 | 0.147645E+10 | 3312.01 | 29-JUN-16:02 | 2654.08 | 0.00 |
| July | 0.00 | 0.00 | 0.242517E+10 | 0.194720E+10 | 2992.11 | 15-JUL-15:10 | 2115.13 | 0.00 |
| August | 0.00 | 0.00 | 0.144908E+10 | 0.117957E+10 | 2761.35 | 08-AUG-16:02 | 2153.92 | 0.00 |
| September | 0.00 | 0.00 | 0.155841E+09 | 0.133532E+09 | 1742.99 | 01-SEP-16:04 | 1580.23 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.653885E+10 | 0.543832E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.242517E+10 | 0.194720E+10 | 3312.01 | 2654.08 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 21473109.02 | 20266942.08 | 1059.49 | 23-APR-18:00 | 988.79 | 0.00 |
| May | 0.00 | 0.00 | 0.720497E+09 | 0.681127E+09 | 2229.96 | 25-MAY-18:00 | 2018.66 | 0.00 |
| June | 0.00 | 0.00 | 0.177455E+10 | 0.148418E+10 | 3291.15 | 29-JUN-16:02 | 2636.01 | 0.00 |
| July | 0.00 | 0.00 | 0.242877E+10 | 0.195055E+10 | 2981.73 | 15-JUL-15:10 | 2107.30 | 0.00 |
| August | 0.00 | 0.00 | 0.145045E+10 | 0.118103E+10 | 2745.39 | 08-AUG-16:02 | 2140.95 | 0.00 |
| September | 0.00 | 0.00 | 0.156671E+09 | 0.134422E+09 | 1726.35 | 01-SEP-16:04 | 1565.31 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.655241E+10 | 0.545158E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.242877E+10 | 0.195055E+10 | 3291.15 | 2636.01 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 2710230.74 | 2710230.74 | 351.59 | 28-FEB-15:10 | 351.59 | 0.00 |
| March | 0.00 | 0.00 | 20900698.02 | 20900698.02 | 719.03 | 26-MAR-15:20 | 719.03 | 0.00 |
| April | 0.00 | 0.00 | 0.251241E+09 | 0.248730E+09 | 2329.56 | 23-APR-15:30 | 2236.78 | 0.00 |
| May | 0.00 | 0.00 | 0.114329E+10 | 0.110205E+10 | 3012.29 | 18-MAY-13:40 | 3004.39 | 0.00 |
| June | 0.00 | 0.00 | 0.209152E+10 | 0.179412E+10 | 3984.22 | 30-JUN-13:40 | 3233.26 | 0.00 |
| July | 0.00 | 0.00 | 0.295836E+10 | 0.244429E+10 | 3890.32 | 23-JUL-13:30 | 3271.01 | 0.00 |
| August | 0.00 | 0.00 | 0.217658E+10 | 0.184841E+10 | 3635.54 | 08-AUG-14:10 | 3015.77 | 0.00 |
| September | 0.00 | 0.00 | 0.762277E+09 | 0.721163E+09 | 3432.88 | 01-SEP-13:30 | 3145.93 | 0.00 |
| October | 0.00 | 0.00 | 0.244998E+09 | 0.244485E+09 | 2201.90 | 22-OCT-13:40 | 2173.99 | 0.00 |
| November | 0.00 | 0.00 | 2077273.24 | 2077273.24 | 315.86 | 17-NOV-13:40 | 315.86 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.965394E+10 | 0.842894E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.295836E+10 | 0.244429E+10 | 3984.22 | 3271.01 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 2881550.21 | 2881550.21 | 362.19 | 28-FEB-15:10 | 362.19 | 0.00 |
| March | 0.00 | 0.00 | 21906646.32 | 21906646.32 | 725.65 | 26-MAR-15:20 | 725.65 | 0.00 |
| April | 0.00 | 0.00 | 0.255838E+09 | 0.253343E+09 | 2315.32 | 23-APR-15:20 | 2227.07 | 0.00 |
| May | 0.00 | 0.00 | 0.114587E+10 | 0.110468E+10 | 3023.80 | 18-MAY-13:40 | 3015.99 | 0.00 |
| June | 0.00 | 0.00 | 0.210036E+10 | 0.180273E+10 | 3989.60 | 30-JUN-13:40 | 3239.26 | 0.00 |
| July | 0.00 | 0.00 | 0.296240E+10 | 0.244817E+10 | 3902.53 | 23-JUL-13:30 | 3283.99 | 0.00 |
| August | 0.00 | 0.00 | 0.217788E+10 | 0.184987E+10 | 3642.49 | 08-AUG-14:10 | 3023.61 | 0.00 |
| September | 0.00 | 0.00 | 0.766395E+09 | 0.725381E+09 | 3447.13 | 01-SEP-13:30 | 3160.78 | 0.00 |
| October | 0.00 | 0.00 | 0.247239E+09 | 0.246715E+09 | 2214.91 | 22-OCT-13:40 | 2187.01 | 0.00 |
| November | 0.00 | 0.00 | 2243920.47 | 2243920.47 | 337.42 | 17-NOV-13:40 | 337.42 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.968302E+10 | 0.845792E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.296240E+10 | 0.244817E+10 | 3989.60 | 3283.99 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.262123E+09 | 0.96 | 169.30 | 09-JAN-08:05 | 0.96 |
| February | 0.186399E+09 | 0.96 | 146.24 | 14-FEB-08:02 | 0.96 |
| March | 0.160068E+09 | 0.94 | 134.93 | 05-MAR-07:00 | 0.96 |
| April | 70504964.30 | 0.72 | 86.62 | 04-APR-07:16 | 0.96 |
| May | 40483643.49 | 0.43 | 153.28 | 25-MAY-17:40 | 1.06 |
| June | 0.101162E+09 | 0.62 | 237.26 | 29-JUN-16:02 | 1.02 |
| July | 0.198945E+09 | 1.00 | 227.62 | 23-JUL-16:05 | 1.02 |
| August | 0.162179E+09 | 0.96 | 218.65 | 08-AUG-16:04 | 1.03 |
| September | 56864427.34 | 0.50 | 189.24 | 01-SEP-16:04 | 1.04 |
| October | 37420307.35 | 0.57 | 100.36 | 22-OCT-15:30 | 1.08 |
| November | 0.112929E+09 | 0.93 | 110.26 | 25-NOV-08:25 | 0.96 |
| December | 0.245812E+09 | 0.96 | 166.37 | 24-DEC-08:08 | 0.96 |
| Annual Sum or Average | 0.163489E+10 | 0.80 | |||
| Minimum of Months | 37420307.35 | 0.43 | 86.62 | 0.96 | |
| Maximum of Months | 0.262123E+09 | 1.00 | 237.26 | 1.08 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.300994E+09 | 0.96 | 178.26 | 05-JAN-08:16 | 0.97 |
| February | 0.226614E+09 | 0.96 | 160.13 | 14-FEB-08:02 | 0.96 |
| March | 0.198813E+09 | 0.96 | 140.97 | 15-MAR-07:20 | 0.96 |
| April | 95093620.84 | 0.88 | 90.76 | 05-APR-04:00 | 0.96 |
| May | 31058043.55 | 0.44 | 132.85 | 25-MAY-18:00 | 1.06 |
| June | 82530397.98 | 0.56 | 218.05 | 29-JUN-16:30 | 1.02 |
| July | 0.163291E+09 | 0.97 | 187.69 | 23-JUL-16:20 | 1.03 |
| August | 0.111808E+09 | 0.86 | 185.11 | 08-AUG-16:30 | 1.03 |
| September | 17165497.47 | 0.30 | 130.86 | 01-SEP-16:04 | 1.06 |
| October | 46824883.25 | 0.73 | 67.46 | 30-OCT-07:03 | 0.96 |
| November | 0.135886E+09 | 0.95 | 111.78 | 25-NOV-08:30 | 0.96 |
| December | 0.274599E+09 | 0.96 | 171.26 | 24-DEC-08:23 | 0.97 |
| Annual Sum or Average | 0.168468E+10 | 0.80 | |||
| Minimum of Months | 17165497.47 | 0.30 | 67.46 | 0.96 | |
| Maximum of Months | 0.300994E+09 | 0.97 | 218.05 | 1.06 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.122313E+10 | 0.96 | 456.66 | 01-JAN-00:10 | 0.97 |
| February | 0.110476E+10 | 0.96 | 456.66 | 01-FEB-00:30 | 0.97 |
| March | 0.122313E+10 | 0.96 | 456.66 | 01-MAR-00:10 | 0.96 |
| April | 0.118367E+10 | 0.96 | 456.66 | 01-APR-00:10 | 0.96 |
| May | 0.122313E+10 | 0.96 | 456.66 | 01-MAY-00:10 | 0.96 |
| June | 0.118367E+10 | 0.95 | 456.66 | 01-JUN-00:10 | 0.96 |
| July | 0.122313E+10 | 0.95 | 456.66 | 01-JUL-00:10 | 0.95 |
| August | 0.122313E+10 | 0.95 | 456.66 | 01-AUG-00:10 | 0.95 |
| September | 0.118367E+10 | 0.95 | 456.66 | 01-SEP-00:10 | 0.94 |
| October | 0.122313E+10 | 0.96 | 456.66 | 01-OCT-00:10 | 0.95 |
| November | 0.118367E+10 | 0.96 | 456.66 | 01-NOV-00:10 | 0.96 |
| December | 0.122313E+10 | 0.96 | 456.66 | 01-DEC-00:10 | 0.96 |
| Annual Sum or Average | 0.144014E+11 | 0.96 | |||
| Minimum of Months | 0.110476E+10 | 0.95 | 456.66 | 0.94 | |
| Maximum of Months | 0.122313E+10 | 0.96 | 456.66 | 0.97 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.293766E+09 | 0.96 | 173.03 | 05-JAN-08:10 | 0.97 |
| February | 0.221528E+09 | 0.96 | 152.92 | 14-FEB-08:00 | 0.96 |
| March | 0.194117E+09 | 0.96 | 133.09 | 15-MAR-05:00 | 0.96 |
| April | 90687892.34 | 0.88 | 90.52 | 05-APR-04:00 | 0.96 |
| May | 28312207.08 | 0.44 | 94.07 | 25-MAY-18:00 | 1.07 |
| June | 86249778.02 | 0.61 | 188.47 | 29-JUN-16:02 | 1.02 |
| July | 0.164049E+09 | 0.96 | 171.78 | 15-JUL-15:10 | 1.03 |
| August | 0.109075E+09 | 0.86 | 162.51 | 08-AUG-16:04 | 1.03 |
| September | 16650201.70 | 0.32 | 106.54 | 01-SEP-16:04 | 1.06 |
| October | 46397987.19 | 0.74 | 66.35 | 30-OCT-07:04 | 0.96 |
| November | 0.132611E+09 | 0.95 | 108.43 | 25-NOV-08:30 | 0.96 |
| December | 0.267857E+09 | 0.96 | 165.44 | 24-DEC-08:10 | 0.97 |
| Annual Sum or Average | 0.165130E+10 | 0.80 | |||
| Minimum of Months | 16650201.70 | 0.32 | 66.35 | 0.96 | |
| Maximum of Months | 0.293766E+09 | 0.96 | 188.47 | 1.07 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.220038E+09 | 0.96 | 131.87 | 05-JAN-08:16 | 0.97 |
| February | 0.164652E+09 | 0.96 | 119.31 | 14-FEB-08:02 | 0.96 |
| March | 0.144438E+09 | 0.96 | 103.86 | 15-MAR-07:20 | 0.96 |
| April | 65339793.80 | 0.89 | 66.27 | 05-APR-04:00 | 0.96 |
| May | 22627879.09 | 0.43 | 90.01 | 25-MAY-18:00 | 1.07 |
| June | 72390998.85 | 0.62 | 161.77 | 29-JUN-16:02 | 1.02 |
| July | 0.137423E+09 | 1.00 | 146.25 | 15-JUL-15:10 | 1.03 |
| August | 94497060.50 | 0.92 | 135.01 | 08-AUG-16:04 | 1.04 |
| September | 13312577.20 | 0.28 | 90.47 | 01-SEP-16:08 | 1.07 |
| October | 28690994.06 | 0.66 | 46.09 | 30-OCT-07:10 | 0.96 |
| November | 93896958.95 | 0.94 | 80.42 | 25-NOV-08:25 | 0.96 |
| December | 0.199061E+09 | 0.96 | 125.33 | 24-DEC-08:27 | 0.96 |
| Annual Sum or Average | 0.125637E+10 | 0.80 | |||
| Minimum of Months | 13312577.20 | 0.28 | 46.09 | 0.96 | |
| Maximum of Months | 0.220038E+09 | 1.00 | 161.77 | 1.07 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.219900E+09 | 0.96 | 131.80 | 05-JAN-08:16 | 0.97 |
| February | 0.164576E+09 | 0.96 | 119.25 | 14-FEB-08:02 | 0.96 |
| March | 0.144358E+09 | 0.96 | 103.73 | 15-MAR-07:20 | 0.96 |
| April | 65253028.25 | 0.89 | 66.30 | 05-APR-04:00 | 0.96 |
| May | 22478536.00 | 0.43 | 88.87 | 25-MAY-18:00 | 1.07 |
| June | 72974741.57 | 0.63 | 161.36 | 29-JUN-16:02 | 1.02 |
| July | 0.137402E+09 | 1.00 | 146.21 | 15-JUL-15:10 | 1.03 |
| August | 94468691.23 | 0.92 | 134.65 | 08-AUG-16:04 | 1.04 |
| September | 13388020.69 | 0.29 | 90.13 | 01-SEP-16:08 | 1.07 |
| October | 28760256.67 | 0.66 | 46.11 | 30-OCT-07:10 | 0.96 |
| November | 93833036.28 | 0.94 | 80.35 | 25-NOV-08:25 | 0.96 |
| December | 0.198932E+09 | 0.96 | 125.25 | 24-DEC-08:27 | 0.96 |
| Annual Sum or Average | 0.125632E+10 | 0.80 | |||
| Minimum of Months | 13388020.69 | 0.29 | 46.11 | 0.96 | |
| Maximum of Months | 0.219900E+09 | 1.00 | 161.36 | 1.07 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.184353E+09 | 0.96 | 125.13 | 09-JAN-08:05 | 0.96 |
| February | 0.127749E+09 | 0.94 | 106.36 | 14-FEB-08:02 | 0.96 |
| March | 0.108583E+09 | 0.93 | 97.96 | 05-MAR-04:00 | 0.96 |
| April | 42454640.19 | 0.66 | 58.67 | 04-APR-07:16 | 0.96 |
| May | 33170964.19 | 0.42 | 112.49 | 25-MAY-16:05 | 1.06 |
| June | 92766618.57 | 0.69 | 183.94 | 30-JUN-15:10 | 1.02 |
| July | 0.174898E+09 | 1.04 | 177.91 | 23-JUL-13:30 | 1.03 |
| August | 0.147684E+09 | 1.02 | 170.35 | 08-AUG-15:10 | 1.03 |
| September | 58483350.93 | 0.62 | 151.85 | 01-SEP-15:10 | 1.04 |
| October | 23347516.75 | 0.50 | 93.79 | 22-OCT-14:00 | 1.07 |
| November | 73278360.71 | 0.90 | 79.44 | 25-NOV-08:25 | 0.96 |
| December | 0.172979E+09 | 0.96 | 121.73 | 24-DEC-08:08 | 0.96 |
| Annual Sum or Average | 0.123975E+10 | 0.80 | |||
| Minimum of Months | 23347516.75 | 0.42 | 58.67 | 0.96 | |
| Maximum of Months | 0.184353E+09 | 1.04 | 183.94 | 1.07 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.198337E+09 | 0.96 | 132.76 | 09-JAN-08:05 | 0.96 |
| February | 0.138640E+09 | 0.95 | 112.63 | 14-FEB-08:02 | 0.96 |
| March | 0.118724E+09 | 0.94 | 104.63 | 05-MAR-04:00 | 0.96 |
| April | 46412751.31 | 0.67 | 63.65 | 04-APR-07:10 | 0.96 |
| May | 36313958.34 | 0.43 | 116.23 | 25-MAY-15:10 | 1.06 |
| June | 0.102347E+09 | 0.73 | 189.69 | 30-JUN-15:10 | 1.02 |
| July | 0.192650E+09 | 1.05 | 189.26 | 23-JUL-13:30 | 1.02 |
| August | 0.163331E+09 | 1.04 | 175.80 | 08-AUG-15:10 | 1.03 |
| September | 65672189.01 | 0.65 | 156.68 | 01-SEP-15:10 | 1.04 |
| October | 25190004.61 | 0.51 | 96.97 | 22-OCT-14:00 | 1.07 |
| November | 81488307.94 | 0.91 | 85.40 | 25-NOV-08:25 | 0.96 |
| December | 0.186144E+09 | 0.96 | 128.95 | 24-DEC-08:06 | 0.96 |
| Annual Sum or Average | 0.135525E+10 | 0.82 | |||
| Minimum of Months | 25190004.61 | 0.43 | 63.65 | 0.96 | |
| Maximum of Months | 0.198337E+09 | 1.05 | 189.69 | 1.07 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.449260E+09 | 0.96 | 333.07 | 04-JAN-06:00 | 0.97 |
| February | 0.295086E+09 | 0.88 | 273.00 | 13-FEB-04:00 | 0.96 |
| March | 0.202547E+09 | 0.78 | 239.41 | 05-MAR-04:00 | 0.96 |
| April | 99987592.41 | 0.55 | 430.79 | 23-APR-16:10 | 1.05 |
| May | 0.242460E+09 | 0.70 | 480.01 | 25-MAY-17:30 | 1.04 |
| June | 0.399216E+09 | 0.93 | 622.42 | 29-JUN-16:02 | 1.02 |
| July | 0.546007E+09 | 1.06 | 575.27 | 23-JUL-16:05 | 1.02 |
| August | 0.416480E+09 | 0.99 | 547.89 | 08-AUG-16:04 | 1.03 |
| September | 0.167187E+09 | 0.58 | 496.64 | 01-SEP-15:30 | 1.04 |
| October | 90271168.55 | 0.55 | 325.37 | 22-OCT-15:30 | 1.07 |
| November | 0.200979E+09 | 0.87 | 225.27 | 25-NOV-06:00 | 0.96 |
| December | 0.442071E+09 | 0.96 | 314.91 | 24-DEC-08:08 | 0.97 |
| Annual Sum or Average | 0.355155E+10 | 0.82 | |||
| Minimum of Months | 90271168.55 | 0.55 | 225.27 | 0.96 | |
| Maximum of Months | 0.546007E+09 | 1.06 | 622.42 | 1.07 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.534039E+09 | 0.96 | 357.35 | 04-JAN-12:00 | 0.97 |
| February | 0.381243E+09 | 0.96 | 294.39 | 14-FEB-05:00 | 0.96 |
| March | 0.280166E+09 | 0.93 | 250.10 | 15-MAR-05:00 | 0.96 |
| April | 96715569.31 | 0.57 | 235.62 | 23-APR-17:30 | 1.08 |
| May | 0.171964E+09 | 0.60 | 450.07 | 25-MAY-18:00 | 1.04 |
| June | 0.353322E+09 | 0.92 | 581.27 | 29-JUN-16:13 | 1.02 |
| July | 0.471227E+09 | 1.06 | 483.19 | 23-JUL-16:20 | 1.03 |
| August | 0.310401E+09 | 0.96 | 471.03 | 08-AUG-16:12 | 1.03 |
| September | 60187076.33 | 0.36 | 342.28 | 01-SEP-16:04 | 1.06 |
| October | 78331928.57 | 0.60 | 133.52 | 30-OCT-07:00 | 0.96 |
| November | 0.250881E+09 | 0.94 | 224.94 | 25-NOV-06:00 | 0.96 |
| December | 0.506078E+09 | 0.96 | 332.18 | 24-DEC-08:55 | 0.97 |
| Annual Sum or Average | 0.349455E+10 | 0.82 | |||
| Minimum of Months | 60187076.33 | 0.36 | 133.52 | 0.96 | |
| Maximum of Months | 0.534039E+09 | 1.06 | 581.27 | 1.08 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.438554E+09 | 0.96 | 325.53 | 04-JAN-06:00 | 0.97 |
| February | 0.288087E+09 | 0.89 | 268.01 | 13-FEB-04:00 | 0.96 |
| March | 0.196885E+09 | 0.78 | 233.61 | 05-MAR-04:00 | 0.96 |
| April | 94407238.10 | 0.54 | 317.02 | 23-APR-16:10 | 1.06 |
| May | 0.230998E+09 | 0.71 | 422.70 | 18-MAY-13:30 | 1.04 |
| June | 0.413105E+09 | 0.94 | 539.32 | 30-JUN-15:10 | 1.01 |
| July | 0.546847E+09 | 1.05 | 522.82 | 23-JUL-13:30 | 1.02 |
| August | 0.409781E+09 | 0.99 | 487.28 | 08-AUG-14:10 | 1.02 |
| September | 0.166895E+09 | 0.59 | 442.84 | 01-SEP-13:30 | 1.04 |
| October | 88086686.58 | 0.57 | 307.16 | 22-OCT-13:40 | 1.06 |
| November | 0.196071E+09 | 0.87 | 219.94 | 25-NOV-06:00 | 0.96 |
| December | 0.431215E+09 | 0.96 | 307.73 | 24-DEC-08:08 | 0.97 |
| Annual Sum or Average | 0.350093E+10 | 0.82 | |||
| Minimum of Months | 88086686.58 | 0.54 | 219.94 | 0.96 | |
| Maximum of Months | 0.546847E+09 | 1.05 | 539.32 | 1.06 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.520340E+09 | 0.96 | 337.98 | 04-JAN-06:00 | 0.97 |
| February | 0.371921E+09 | 0.96 | 290.66 | 14-FEB-05:00 | 0.96 |
| March | 0.272358E+09 | 0.95 | 245.07 | 15-MAR-05:00 | 0.96 |
| April | 87808523.51 | 0.55 | 143.21 | 05-APR-04:00 | 0.96 |
| May | 0.158864E+09 | 0.62 | 317.02 | 25-MAY-18:00 | 1.05 |
| June | 0.367814E+09 | 0.93 | 476.44 | 29-JUN-16:02 | 1.02 |
| July | 0.472920E+09 | 1.04 | 427.27 | 15-JUL-14:30 | 1.03 |
| August | 0.304514E+09 | 0.95 | 394.33 | 08-AUG-16:04 | 1.04 |
| September | 58788472.53 | 0.39 | 262.63 | 01-SEP-11:00 | 1.06 |
| October | 77417254.57 | 0.62 | 130.92 | 30-OCT-07:00 | 0.96 |
| November | 0.244482E+09 | 0.94 | 219.12 | 25-NOV-06:00 | 0.96 |
| December | 0.492707E+09 | 0.96 | 314.33 | 24-DEC-08:02 | 0.97 |
| Annual Sum or Average | 0.342993E+10 | 0.82 | |||
| Minimum of Months | 58788472.53 | 0.39 | 130.92 | 0.96 | |
| Maximum of Months | 0.520340E+09 | 1.04 | 476.44 | 1.06 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.366670E+09 | 0.96 | 238.16 | 04-JAN-12:00 | 0.97 |
| February | 0.260968E+09 | 0.96 | 207.99 | 14-FEB-05:00 | 0.96 |
| March | 0.193214E+09 | 0.93 | 172.11 | 15-MAR-05:00 | 0.96 |
| April | 56044021.91 | 0.53 | 101.86 | 05-APR-04:00 | 0.96 |
| May | 0.126634E+09 | 0.62 | 277.92 | 25-MAY-18:00 | 1.06 |
| June | 0.287043E+09 | 1.00 | 391.08 | 29-JUN-16:02 | 1.03 |
| July | 0.373112E+09 | 1.07 | 350.21 | 15-JUL-15:10 | 1.03 |
| August | 0.254011E+09 | 1.03 | 316.53 | 08-AUG-16:04 | 1.04 |
| September | 50907085.77 | 0.44 | 209.80 | 01-SEP-16:08 | 1.07 |
| October | 38779034.52 | 0.50 | 85.56 | 30-OCT-07:00 | 0.96 |
| November | 0.157665E+09 | 0.93 | 151.44 | 25-NOV-06:00 | 0.96 |
| December | 0.342261E+09 | 0.96 | 225.26 | 24-DEC-08:55 | 0.97 |
| Annual Sum or Average | 0.250731E+10 | 0.83 | |||
| Minimum of Months | 38779034.52 | 0.44 | 85.56 | 0.96 | |
| Maximum of Months | 0.373112E+09 | 1.07 | 391.08 | 1.07 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.366440E+09 | 0.96 | 237.73 | 04-JAN-12:00 | 0.97 |
| February | 0.260853E+09 | 0.96 | 208.06 | 14-FEB-05:00 | 0.96 |
| March | 0.193151E+09 | 0.93 | 172.05 | 15-MAR-05:00 | 0.96 |
| April | 55896644.96 | 0.53 | 101.94 | 05-APR-04:00 | 0.96 |
| May | 0.126436E+09 | 0.62 | 275.24 | 25-MAY-18:00 | 1.06 |
| June | 0.287783E+09 | 1.00 | 389.67 | 29-JUN-16:02 | 1.03 |
| July | 0.373164E+09 | 1.07 | 349.67 | 15-JUL-15:10 | 1.03 |
| August | 0.253913E+09 | 1.02 | 315.63 | 08-AUG-16:04 | 1.04 |
| September | 51220851.65 | 0.44 | 208.85 | 01-SEP-16:08 | 1.07 |
| October | 38882212.64 | 0.51 | 85.54 | 30-OCT-07:00 | 0.96 |
| November | 0.157550E+09 | 0.93 | 151.34 | 25-NOV-06:00 | 0.96 |
| December | 0.342031E+09 | 0.96 | 224.98 | 24-DEC-08:55 | 0.97 |
| Annual Sum or Average | 0.250732E+10 | 0.83 | |||
| Minimum of Months | 38882212.64 | 0.44 | 85.54 | 0.96 | |
| Maximum of Months | 0.373164E+09 | 1.07 | 389.67 | 1.07 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.288518E+09 | 0.96 | 218.30 | 04-JAN-06:00 | 0.96 |
| February | 0.181315E+09 | 0.82 | 186.49 | 14-FEB-05:00 | 0.96 |
| March | 0.119948E+09 | 0.70 | 166.56 | 05-MAR-04:00 | 0.96 |
| April | 58353557.61 | 0.46 | 292.41 | 23-APR-16:10 | 1.06 |
| May | 0.196604E+09 | 0.74 | 343.91 | 18-MAY-13:40 | 1.05 |
| June | 0.333381E+09 | 1.02 | 446.29 | 30-JUN-15:10 | 1.02 |
| July | 0.448927E+09 | 1.07 | 432.86 | 23-JUL-13:30 | 1.03 |
| August | 0.361904E+09 | 1.05 | 404.77 | 08-AUG-15:10 | 1.03 |
| September | 0.165896E+09 | 0.69 | 382.69 | 01-SEP-13:30 | 1.04 |
| October | 62020542.73 | 0.45 | 300.76 | 22-OCT-13:40 | 1.06 |
| November | 0.111533E+09 | 0.77 | 151.69 | 25-NOV-06:00 | 0.96 |
| December | 0.283773E+09 | 0.96 | 211.89 | 24-DEC-08:09 | 0.96 |
| Annual Sum or Average | 0.261217E+10 | 0.81 | |||
| Minimum of Months | 58353557.61 | 0.45 | 151.69 | 0.96 | |
| Maximum of Months | 0.448927E+09 | 1.07 | 446.29 | 1.06 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.288331E+09 | 0.96 | 218.18 | 04-JAN-06:00 | 0.96 |
| February | 0.181285E+09 | 0.82 | 186.54 | 14-FEB-05:00 | 0.96 |
| March | 0.119936E+09 | 0.70 | 166.47 | 05-MAR-04:00 | 0.96 |
| April | 58931187.84 | 0.46 | 290.89 | 23-APR-16:10 | 1.06 |
| May | 0.196570E+09 | 0.74 | 344.72 | 18-MAY-13:40 | 1.05 |
| June | 0.334113E+09 | 1.02 | 445.36 | 30-JUN-15:10 | 1.02 |
| July | 0.448976E+09 | 1.07 | 433.58 | 23-JUL-13:30 | 1.03 |
| August | 0.361771E+09 | 1.05 | 404.51 | 08-AUG-15:10 | 1.03 |
| September | 0.166017E+09 | 0.69 | 383.68 | 01-SEP-13:30 | 1.04 |
| October | 61979767.45 | 0.45 | 301.43 | 22-OCT-13:40 | 1.06 |
| November | 0.111481E+09 | 0.77 | 151.60 | 25-NOV-06:00 | 0.96 |
| December | 0.283582E+09 | 0.96 | 211.79 | 24-DEC-08:09 | 0.96 |
| Annual Sum or Average | 0.261297E+10 | 0.81 | |||
| Minimum of Months | 58931187.84 | 0.45 | 151.60 | 0.96 | |
| Maximum of Months | 0.448976E+09 | 1.07 | 445.36 | 1.06 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.66 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.66 |
| March | 0.107173E+09 | 0.66 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.66 | 40.01 | 01-APR-00:10 | 0.66 |
| May | 0.107173E+09 | 0.66 | 40.01 | 01-MAY-00:10 | 0.66 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.66 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.66 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.66 | 40.01 | 01-OCT-00:10 | 0.66 |
| November | 0.103716E+09 | 0.66 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.66 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.348799E+09 | 0.96 | 250.40 | 04-JAN-06:00 | 0.97 |
| February | 0.242556E+09 | 0.91 | 216.29 | 14-FEB-06:00 | 0.96 |
| March | 0.187142E+09 | 0.86 | 185.12 | 05-MAR-04:00 | 0.96 |
| April | 0.109513E+09 | 0.75 | 267.08 | 23-APR-16:10 | 1.04 |
| May | 0.127956E+09 | 0.64 | 299.90 | 18-MAY-15:20 | 1.03 |
| June | 0.195192E+09 | 0.68 | 391.73 | 29-JUN-16:02 | 1.00 |
| July | 0.268390E+09 | 0.82 | 361.06 | 29-JUL-16:10 | 1.01 |
| August | 0.193309E+09 | 0.68 | 350.91 | 08-AUG-15:30 | 1.01 |
| September | 80366777.00 | 0.56 | 318.45 | 01-SEP-15:30 | 1.02 |
| October | 95718847.78 | 0.80 | 194.56 | 19-OCT-15:10 | 1.06 |
| November | 0.175970E+09 | 0.90 | 170.12 | 25-NOV-07:00 | 0.96 |
| December | 0.340923E+09 | 0.96 | 235.70 | 24-DEC-08:05 | 0.97 |
| Annual Sum or Average | 0.236584E+10 | 0.79 | |||
| Minimum of Months | 80366777.00 | 0.56 | 170.12 | 0.96 | |
| Maximum of Months | 0.348799E+09 | 0.96 | 391.73 | 1.06 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.394990E+09 | 0.96 | 253.24 | 04-JAN-06:00 | 0.97 |
| February | 0.288993E+09 | 0.96 | 221.64 | 14-FEB-05:00 | 0.96 |
| March | 0.222969E+09 | 0.93 | 191.57 | 15-MAR-05:00 | 0.96 |
| April | 0.103732E+09 | 0.76 | 183.41 | 23-APR-17:15 | 1.06 |
| May | 94686607.43 | 0.60 | 282.05 | 25-MAY-18:00 | 1.03 |
| June | 0.170716E+09 | 0.68 | 367.71 | 29-JUN-16:13 | 1.00 |
| July | 0.229571E+09 | 0.83 | 307.65 | 23-JUL-16:30 | 1.02 |
| August | 0.140957E+09 | 0.65 | 302.57 | 08-AUG-16:12 | 1.02 |
| September | 36507964.19 | 0.47 | 220.62 | 01-SEP-16:15 | 1.05 |
| October | 91261141.42 | 0.82 | 115.29 | 30-OCT-07:00 | 0.96 |
| November | 0.203280E+09 | 0.95 | 169.88 | 25-NOV-06:00 | 0.96 |
| December | 0.375988E+09 | 0.96 | 244.70 | 24-DEC-09:00 | 0.97 |
| Annual Sum or Average | 0.235365E+10 | 0.80 | |||
| Minimum of Months | 36507964.19 | 0.47 | 115.29 | 0.96 | |
| Maximum of Months | 0.394990E+09 | 0.96 | 367.71 | 1.06 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.338441E+09 | 0.96 | 243.01 | 04-JAN-06:00 | 0.97 |
| February | 0.234774E+09 | 0.90 | 210.94 | 14-FEB-06:00 | 0.96 |
| March | 0.178051E+09 | 0.85 | 179.88 | 15-MAR-05:00 | 0.96 |
| April | 0.100514E+09 | 0.74 | 190.62 | 23-APR-15:30 | 1.05 |
| May | 0.117833E+09 | 0.65 | 271.14 | 18-MAY-13:30 | 1.02 |
| June | 0.198293E+09 | 0.74 | 341.26 | 30-JUN-13:20 | 0.99 |
| July | 0.268202E+09 | 0.85 | 332.49 | 23-JUL-13:30 | 1.00 |
| August | 0.187892E+09 | 0.70 | 311.60 | 08-AUG-14:10 | 1.00 |
| September | 78730435.98 | 0.57 | 284.01 | 01-SEP-13:30 | 1.02 |
| October | 93159716.45 | 0.81 | 173.63 | 22-OCT-13:40 | 1.06 |
| November | 0.170693E+09 | 0.90 | 164.96 | 25-NOV-07:00 | 0.96 |
| December | 0.330553E+09 | 0.96 | 228.58 | 24-DEC-08:07 | 0.97 |
| Annual Sum or Average | 0.229714E+10 | 0.80 | |||
| Minimum of Months | 78730435.98 | 0.57 | 164.96 | 0.96 | |
| Maximum of Months | 0.338441E+09 | 0.96 | 341.26 | 1.06 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.382688E+09 | 0.96 | 245.32 | 04-JAN-06:00 | 0.97 |
| February | 0.279999E+09 | 0.96 | 215.85 | 14-FEB-05:00 | 0.96 |
| March | 0.215502E+09 | 0.96 | 186.31 | 15-MAR-05:00 | 0.96 |
| April | 93264488.33 | 0.73 | 120.39 | 05-APR-04:00 | 0.96 |
| May | 83525538.34 | 0.59 | 190.71 | 25-MAY-16:05 | 1.05 |
| June | 0.174725E+09 | 0.74 | 294.45 | 29-JUN-16:02 | 1.00 |
| July | 0.230954E+09 | 0.85 | 259.35 | 15-JUL-14:40 | 1.01 |
| August | 0.135755E+09 | 0.66 | 245.06 | 08-AUG-16:04 | 1.02 |
| September | 31614551.06 | 0.46 | 162.01 | 01-SEP-11:00 | 1.05 |
| October | 88459688.47 | 0.82 | 112.20 | 30-OCT-07:00 | 0.96 |
| November | 0.196905E+09 | 0.95 | 164.43 | 25-NOV-06:00 | 0.96 |
| December | 0.363991E+09 | 0.96 | 231.13 | 24-DEC-08:02 | 0.97 |
| Annual Sum or Average | 0.227738E+10 | 0.80 | |||
| Minimum of Months | 31614551.06 | 0.46 | 112.20 | 0.96 | |
| Maximum of Months | 0.382688E+09 | 0.96 | 294.45 | 1.05 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.286832E+09 | 0.96 | 178.25 | 04-JAN-06:00 | 0.97 |
| February | 0.209354E+09 | 0.96 | 162.89 | 14-FEB-05:00 | 0.96 |
| March | 0.162956E+09 | 0.95 | 137.09 | 15-MAR-05:00 | 0.96 |
| April | 68185009.96 | 0.71 | 89.90 | 05-APR-04:00 | 0.96 |
| May | 61491698.69 | 0.54 | 172.55 | 25-MAY-18:00 | 1.05 |
| June | 0.133083E+09 | 0.73 | 247.03 | 29-JUN-16:02 | 1.02 |
| July | 0.180470E+09 | 0.87 | 214.33 | 15-JUL-15:10 | 1.03 |
| August | 0.108737E+09 | 0.69 | 201.97 | 08-AUG-16:02 | 1.03 |
| September | 18779285.61 | 0.37 | 132.34 | 01-SEP-16:04 | 1.06 |
| October | 59206703.61 | 0.79 | 81.21 | 30-OCT-07:00 | 0.96 |
| November | 0.140995E+09 | 0.94 | 121.64 | 25-NOV-06:00 | 0.96 |
| December | 0.270235E+09 | 0.96 | 174.50 | 24-DEC-08:55 | 0.97 |
| Annual Sum or Average | 0.170033E+10 | 0.79 | |||
| Minimum of Months | 18779285.61 | 0.37 | 81.21 | 0.96 | |
| Maximum of Months | 0.286832E+09 | 0.96 | 247.03 | 1.06 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.286464E+09 | 0.96 | 178.03 | 04-JAN-06:00 | 0.97 |
| February | 0.209116E+09 | 0.96 | 162.76 | 14-FEB-05:00 | 0.96 |
| March | 0.162811E+09 | 0.95 | 136.96 | 15-MAR-05:00 | 0.96 |
| April | 68009630.41 | 0.71 | 89.96 | 05-APR-04:00 | 0.96 |
| May | 61529023.07 | 0.53 | 169.77 | 25-MAY-18:00 | 1.05 |
| June | 0.133670E+09 | 0.73 | 245.42 | 29-JUN-16:02 | 1.02 |
| July | 0.180696E+09 | 0.87 | 213.51 | 15-JUL-15:10 | 1.03 |
| August | 0.108822E+09 | 0.69 | 200.76 | 08-AUG-16:02 | 1.03 |
| September | 18875221.72 | 0.37 | 131.09 | 01-SEP-16:04 | 1.06 |
| October | 59248244.71 | 0.79 | 81.12 | 30-OCT-07:00 | 0.96 |
| November | 0.140813E+09 | 0.94 | 121.46 | 25-NOV-06:00 | 0.96 |
| December | 0.269873E+09 | 0.96 | 174.09 | 24-DEC-08:55 | 0.97 |
| Annual Sum or Average | 0.169993E+10 | 0.79 | |||
| Minimum of Months | 18875221.72 | 0.37 | 81.12 | 0.96 | |
| Maximum of Months | 0.286464E+09 | 0.96 | 245.42 | 1.06 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.243053E+09 | 0.96 | 175.62 | 04-JAN-06:00 | 0.97 |
| February | 0.165576E+09 | 0.89 | 157.05 | 14-FEB-06:00 | 0.96 |
| March | 0.126646E+09 | 0.83 | 136.62 | 05-MAR-04:00 | 0.96 |
| April | 69847025.29 | 0.69 | 177.19 | 23-APR-15:30 | 1.05 |
| May | 93372812.51 | 0.62 | 229.18 | 18-MAY-13:40 | 1.03 |
| June | 0.157525E+09 | 0.72 | 288.02 | 30-JUN-14:30 | 1.00 |
| July | 0.219393E+09 | 0.86 | 281.41 | 23-JUL-13:30 | 1.01 |
| August | 0.162294E+09 | 0.73 | 263.89 | 08-AUG-14:10 | 1.01 |
| September | 63755902.47 | 0.51 | 250.11 | 01-SEP-13:30 | 1.02 |
| October | 64907712.55 | 0.73 | 167.43 | 22-OCT-13:40 | 1.06 |
| November | 0.115930E+09 | 0.88 | 122.04 | 25-NOV-06:00 | 0.96 |
| December | 0.237091E+09 | 0.96 | 168.02 | 24-DEC-08:07 | 0.96 |
| Annual Sum or Average | 0.171939E+10 | 0.78 | |||
| Minimum of Months | 63755902.47 | 0.51 | 122.04 | 0.96 | |
| Maximum of Months | 0.243053E+09 | 0.96 | 288.02 | 1.06 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.242764E+09 | 0.96 | 175.42 | 04-JAN-06:00 | 0.97 |
| February | 0.165443E+09 | 0.89 | 156.95 | 14-FEB-06:00 | 0.96 |
| March | 0.126646E+09 | 0.83 | 136.45 | 05-MAR-04:00 | 0.96 |
| April | 70147780.11 | 0.69 | 176.03 | 23-APR-15:20 | 1.05 |
| May | 93584811.01 | 0.62 | 229.86 | 18-MAY-13:40 | 1.03 |
| June | 0.158147E+09 | 0.73 | 287.71 | 30-JUN-13:40 | 1.00 |
| July | 0.219613E+09 | 0.86 | 282.06 | 23-JUL-13:30 | 1.01 |
| August | 0.162330E+09 | 0.73 | 264.21 | 08-AUG-14:10 | 1.01 |
| September | 64099913.04 | 0.51 | 250.93 | 01-SEP-13:30 | 1.02 |
| October | 65108488.17 | 0.73 | 168.29 | 22-OCT-13:40 | 1.06 |
| November | 0.115822E+09 | 0.88 | 121.89 | 25-NOV-06:00 | 0.96 |
| December | 0.236793E+09 | 0.96 | 167.82 | 24-DEC-08:07 | 0.96 |
| Annual Sum or Average | 0.172050E+10 | 0.78 | |||
| Minimum of Months | 64099913.04 | 0.51 | 121.89 | 0.96 | |
| Maximum of Months | 0.242764E+09 | 0.96 | 287.71 | 1.06 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.66 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.66 |
| March | 53586505.42 | 0.66 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.66 | 20.01 | 01-APR-00:10 | 0.66 |
| May | 53586505.42 | 0.66 | 20.01 | 01-MAY-00:10 | 0.66 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.66 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.66 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.66 | 20.01 | 01-OCT-00:10 | 0.66 |
| November | 51857908.47 | 0.66 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.66 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.262123E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.186399E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.160068E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 74413654.26 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.154029E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.443763E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.867156E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.701097E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.242282E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 57253905.09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.112929E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.245812E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.350732E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 57253905.09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.867156E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.300994E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.226614E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.198813E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 95093620.84 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 97175876.65 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.363191E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.712515E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.484346E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 72020943.03 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 46824883.25 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.135886E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.274599E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.300807E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 46824883.25 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.712515E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.122313E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.110476E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.122313E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.118618E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.136676E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.155856E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.172644E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.170267E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.137715E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.124954E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.118367E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.122313E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.161251E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.110476E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.172644E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.293766E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.221528E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.194117E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 90687892.34 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 86626647.12 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.378786E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.715465E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.472415E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 69377268.48 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 46397987.19 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.132611E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.267857E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.296963E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 46397987.19 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.715465E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.220038E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.164652E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.144438E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 65339793.80 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 74574120.93 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.318330E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.599613E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.409414E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 57147214.50 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 28690994.06 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 93896958.95 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.199061E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.237520E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 28690994.06 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.599613E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.219900E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.164576E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.144358E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 65253028.25 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 73882491.92 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.320817E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.599526E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.409290E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 57468364.64 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 28760256.67 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 93833036.28 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.198932E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.237660E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 28760256.67 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.599526E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.184353E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.127749E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.108583E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 44783247.03 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.133757E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.406381E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.762192E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.638336E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.249296E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 46502949.90 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 73278360.71 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.172979E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.294819E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 44783247.03 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.762192E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.198337E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.138640E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.118724E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 48660340.67 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.146602E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.447742E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.838811E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.705566E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.279912E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 49899107.55 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 81488307.94 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.186144E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.324053E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 48660340.67 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.838811E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.449260E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.295086E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.202888E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.230335E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.103418E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.173443E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.237551E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.179900E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.711910E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.208441E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.200979E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.442071E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.968410E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.200979E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.237551E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.534039E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.381243E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.280166E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.111395E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.730991E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.153670E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.205112E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.134278E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.257430E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 78331928.57 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.250881E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.506078E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.806115E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 78331928.57 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.205112E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.438554E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.288087E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.196885E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.218690E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.986025E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.179223E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.237779E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.176956E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.710517E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.201914E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.196071E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.431215E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.960754E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.196071E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.237779E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.520340E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.371921E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.272358E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 95424146.63 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.676489E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.159710E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.205713E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.131685E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.251405E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 77417254.57 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.244482E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.492707E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.797363E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 77417254.57 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.205713E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.366670E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.260968E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.193214E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 60678024.60 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.539891E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.124815E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.162432E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.109894E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.218195E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 38779034.52 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.157665E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.342261E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.614974E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 38779034.52 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.162432E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.366440E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.260853E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.193151E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 60420335.84 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.539151E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.125128E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.162455E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.109852E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.219523E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 38882212.64 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.157550E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.342031E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.615235E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 38882212.64 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.162455E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.288518E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.181315E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.119948E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.158373E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.840157E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.144791E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.195341E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.156313E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.706728E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.194381E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.111533E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.283773E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.784918E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.111533E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.195341E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.288331E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.181285E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.119936E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.160914E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.840025E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.145100E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.195362E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.156255E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.707235E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.194143E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.111481E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.283582E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.785410E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.111481E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.195362E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.348799E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.243228E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.199001E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.205941E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.517198E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.849222E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.117047E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.834543E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.305143E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.162305E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.175970E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.340923E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.535274E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.162305E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.117047E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.394990E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.288993E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.222969E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.123489E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.371166E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.743858E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.100186E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.609075E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.107183E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 92312717.42 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.203280E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.375988E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.453516E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 92312717.42 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.100186E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.338441E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.234774E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.182145E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.184734E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.476806E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.861829E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.116866E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.811185E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.298916E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.157400E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.170693E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.330553E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.521614E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.157400E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.116866E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.382688E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.279999E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.215502E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.100745E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.326544E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.760327E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.100688E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.586734E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 88693692.22 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 88484760.31 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.196905E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.363991E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.439749E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 88484760.31 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.100688E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.286832E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.209354E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.162956E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 73905021.56 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.246981E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.580987E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.787803E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.471171E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 58239288.31 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 59206703.61 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.140995E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.270235E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.334867E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 58239288.31 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.787803E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.286464E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.209116E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.162811E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 73606497.85 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.247041E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.583490E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.788759E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.471537E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 58549138.62 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 59248244.71 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.140813E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.269873E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.335131E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 58549138.62 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.788759E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.243053E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.166302E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.132191E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.135384E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.386822E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.686259E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.956952E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.701763E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.256912E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.127754E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.116486E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.237091E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.414697E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.116486E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.956952E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.242764E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.166215E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.132459E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.136877E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.387608E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.688906E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.957877E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.701913E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.258243E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.128507E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.116422E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.236793E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.415458E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.116422E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.957877E+09 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.262123E+09 | 0.00 | 0.614518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.186399E+09 | 0.00 | 0.436991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.160068E+09 | 0.00 | 0.375260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 70504964.30 | 14908821.17 | 0.162545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 40483643.49 | 0.436846E+09 | 0.148046E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.101162E+09 | 0.134267E+10 | 37298.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.198945E+09 | 0.266573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.162179E+09 | 0.215856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 56864427.34 | 0.726915E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 37420307.35 | 76384713.66 | 0.733571E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.112929E+09 | 0.00 | 0.264750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.245812E+09 | 0.00 | 0.576278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163489E+10 | 0.742202E+10 | 0.251851E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 37420307.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.262123E+09 | 0.266573E+10 | 0.614518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.300994E+09 | 0.00 | 0.716858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.226614E+09 | 0.00 | 0.539712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.198813E+09 | 0.00 | 0.473502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 95093620.84 | 0.00 | 0.226479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 31058043.55 | 0.253586E+09 | 0.268213E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 82530397.98 | 0.110155E+10 | 321794.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.163291E+09 | 0.219109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.111808E+09 | 0.148859E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 17165497.47 | 0.215080E+09 | 10815169.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 46824883.25 | 0.00 | 0.111520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.135886E+09 | 0.00 | 0.323632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.274599E+09 | 0.00 | 0.653996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.168468E+10 | 0.524990E+10 | 0.307363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17165497.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.300994E+09 | 0.219109E+10 | 0.716858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.122313E+10 | 0.00 | 0.487076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.110476E+10 | 0.00 | 0.301020E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122313E+10 | 0.00 | 0.221263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.118367E+10 | 9392602.47 | 0.427440E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.122313E+10 | 0.564922E+09 | 13293148.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.118367E+10 | 0.150721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.122313E+10 | 0.207444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.122313E+10 | 0.197985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.118367E+10 | 0.775841E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.122313E+10 | 0.101445E+09 | 0.128951E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.118367E+10 | 0.00 | 0.113831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122313E+10 | 0.00 | 0.422694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.144014E+11 | 0.701311E+10 | 0.160285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.110476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.122313E+10 | 0.207444E+10 | 0.487076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.293766E+09 | 0.00 | 0.716162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.221528E+09 | 0.00 | 0.540056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194117E+09 | 0.00 | 0.473231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 90687892.34 | 0.00 | 0.221085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 28312207.08 | 0.223841E+09 | 0.264318E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 86249778.02 | 0.115275E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.164049E+09 | 0.220924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.109075E+09 | 0.145573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 16650201.70 | 0.207019E+09 | 14397712.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 46397987.19 | 0.00 | 0.113112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.132611E+09 | 0.00 | 0.323288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.267857E+09 | 0.00 | 0.653000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.165130E+10 | 0.524858E+10 | 0.306781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 16650201.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.293766E+09 | 0.220924E+10 | 0.716162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.220038E+09 | 0.00 | 0.548847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.164652E+09 | 0.00 | 0.410697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144438E+09 | 0.00 | 0.360276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65339793.80 | 0.00 | 0.162979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22627879.09 | 0.199911E+09 | 0.175965E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 72390998.85 | 0.970429E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.137423E+09 | 0.185006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 94497060.50 | 0.126083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 13312577.20 | 0.172565E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28690994.06 | 0.00 | 0.715646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93896958.95 | 0.00 | 0.234209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.199061E+09 | 0.00 | 0.496523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125637E+10 | 0.445379E+10 | 0.230269E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13312577.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.220038E+09 | 0.185006E+10 | 0.548847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.219900E+09 | 0.00 | 0.548819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.164576E+09 | 0.00 | 0.410743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144358E+09 | 0.00 | 0.360283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65253028.25 | 0.00 | 0.162856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22478536.00 | 0.197798E+09 | 0.176421E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 72974741.57 | 0.977955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.137402E+09 | 0.184996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 94468691.23 | 0.126052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 13388020.69 | 0.173518E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28760256.67 | 0.00 | 0.717788E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93833036.28 | 0.00 | 0.234185E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.198932E+09 | 0.00 | 0.496488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125632E+10 | 0.445974E+10 | 0.230280E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13388020.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.219900E+09 | 0.184996E+10 | 0.548819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.184353E+09 | 0.00 | 0.447899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.127749E+09 | 0.00 | 0.310377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.108583E+09 | 0.00 | 0.263810E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 42454640.19 | 8836426.41 | 0.101453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 33170964.19 | 0.387786E+09 | 69895202.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 92766618.57 | 0.123401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.174898E+09 | 0.234936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.147684E+09 | 0.196883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58483350.93 | 0.748821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 23347516.75 | 89325360.03 | 0.393377E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73278360.71 | 0.00 | 0.178035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.172979E+09 | 0.00 | 0.420266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.123975E+10 | 0.678697E+10 | 0.176817E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23347516.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.184353E+09 | 0.234936E+10 | 0.447899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.198337E+09 | 0.00 | 0.481312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.138640E+09 | 0.00 | 0.336443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118724E+09 | 0.00 | 0.288111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 46412751.31 | 8523722.91 | 0.110999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 36313958.34 | 0.425829E+09 | 74479692.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.102347E+09 | 0.136163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.192650E+09 | 0.258942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.163331E+09 | 0.217841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 65672189.01 | 0.841661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 25190004.61 | 95327687.34 | 0.425951E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 81488307.94 | 0.00 | 0.197751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.186144E+09 | 0.00 | 0.451723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.135525E+10 | 0.750079E+10 | 0.191638E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 25190004.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.198337E+09 | 0.258942E+10 | 0.481312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.449260E+09 | 0.00 | 0.101875E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.295086E+09 | 0.00 | 0.669140E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.202547E+09 | 1271940.30 | 0.459055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 99987592.41 | 0.498933E+09 | 0.134716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.242460E+09 | 0.307263E+10 | 14619577.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.399216E+09 | 0.525496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.546007E+09 | 0.729309E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.416480E+09 | 0.553056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.167187E+09 | 0.213613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 90271168.55 | 0.457782E+09 | 0.121809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.200979E+09 | 0.00 | 0.455743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.442071E+09 | 0.00 | 0.100244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.355155E+10 | 0.242454E+11 | 0.386311E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 90271168.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.546007E+09 | 0.729309E+10 | 0.101875E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.534039E+09 | 0.00 | 0.122108E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.381243E+09 | 0.00 | 0.871709E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.280166E+09 | 0.00 | 0.640597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96715569.31 | 56463819.62 | 0.211034E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.171964E+09 | 0.216589E+10 | 45220368.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.353322E+09 | 0.465590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.471227E+09 | 0.629160E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.310401E+09 | 0.411460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 60187076.33 | 0.772031E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 78331928.57 | 0.00 | 0.179105E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.250881E+09 | 0.00 | 0.573637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.506078E+09 | 0.00 | 0.115714E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.349455E+10 | 0.180565E+11 | 0.485882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 60187076.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.534039E+09 | 0.629160E+10 | 0.122108E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.438554E+09 | 0.00 | 0.101676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288087E+09 | 0.00 | 0.667911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.196885E+09 | 0.00 | 0.456464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 94407238.10 | 0.474887E+09 | 0.129070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.230998E+09 | 0.293859E+10 | 7392579.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.413105E+09 | 0.545927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.546847E+09 | 0.734564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.409781E+09 | 0.546655E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.166895E+09 | 0.213840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88086686.58 | 0.442611E+09 | 0.122634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.196071E+09 | 0.00 | 0.454579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.431215E+09 | 0.00 | 0.999745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350093E+10 | 0.242659E+11 | 0.384790E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 88086686.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.546847E+09 | 0.734564E+10 | 0.101676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.520340E+09 | 0.00 | 0.121935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.371921E+09 | 0.00 | 0.871551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.272358E+09 | 0.00 | 0.638238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87808523.51 | 29020309.57 | 0.200403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.158864E+09 | 0.201135E+10 | 35127736.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.367814E+09 | 0.486184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.472920E+09 | 0.634609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.304514E+09 | 0.404858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58788472.53 | 0.754166E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 77417254.57 | 0.00 | 0.181418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.244482E+09 | 0.00 | 0.572913E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.492707E+09 | 0.00 | 0.115460E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.342993E+10 | 0.180510E+11 | 0.484198E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58788472.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.520340E+09 | 0.634609E+10 | 0.121935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.366670E+09 | 0.00 | 0.875898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260968E+09 | 0.00 | 0.623399E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.193214E+09 | 0.00 | 0.461548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 56044021.91 | 17595638.90 | 0.130555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.126634E+09 | 0.160145E+10 | 26697799.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.287043E+09 | 0.378975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.373112E+09 | 0.499601E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.254011E+09 | 0.337224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 50907085.77 | 0.656342E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 38779034.52 | 0.00 | 0.926351E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.157665E+09 | 0.00 | 0.376628E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.342261E+09 | 0.00 | 0.817591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.250731E+10 | 0.144334E+11 | 0.338092E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 38779034.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.373112E+09 | 0.499601E+10 | 0.875898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.366440E+09 | 0.00 | 0.875849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260853E+09 | 0.00 | 0.623481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.193151E+09 | 0.00 | 0.461660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 55896644.96 | 17171125.32 | 0.130357E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.126436E+09 | 0.159940E+10 | 25874682.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.287783E+09 | 0.379949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.373164E+09 | 0.499723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.253913E+09 | 0.337115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 51220851.65 | 0.660240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 38882212.64 | 0.00 | 0.929346E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.157550E+09 | 0.00 | 0.376569E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.342031E+09 | 0.00 | 0.817508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.250732E+10 | 0.144447E+11 | 0.338095E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 38882212.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.373164E+09 | 0.499723E+10 | 0.875849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.288518E+09 | 0.00 | 0.678851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.181315E+09 | 0.00 | 0.426615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119948E+09 | 0.00 | 0.282225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 58353557.61 | 0.381937E+09 | 0.640509E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196604E+09 | 0.249511E+10 | 1110383.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.333381E+09 | 0.439393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.448927E+09 | 0.601177E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.361904E+09 | 0.481417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.165896E+09 | 0.212307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 62020542.73 | 0.514618E+09 | 0.495913E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111533E+09 | 0.00 | 0.262425E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283773E+09 | 0.00 | 0.667688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.261217E+10 | 0.207346E+11 | 0.243156E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58353557.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.448927E+09 | 0.601177E+10 | 0.678851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.288331E+09 | 0.00 | 0.678770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.181285E+09 | 0.00 | 0.426769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119936E+09 | 0.00 | 0.282346E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 58931187.84 | 0.389410E+09 | 0.639858E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196570E+09 | 0.249489E+10 | 869982.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.334113E+09 | 0.440385E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.448976E+09 | 0.601326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.361771E+09 | 0.481301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.166017E+09 | 0.212481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 61979767.45 | 0.513945E+09 | 0.496669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111481E+09 | 0.00 | 0.262441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283582E+09 | 0.00 | 0.667590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.261297E+10 | 0.207532E+11 | 0.243166E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58931187.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.448976E+09 | 0.601326E+10 | 0.678770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.348799E+09 | 0.00 | 0.782277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.242556E+09 | 2508428.87 | 0.543523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.187142E+09 | 44870784.90 | 0.411360E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.109513E+09 | 0.371069E+09 | 0.178085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.127956E+09 | 0.151775E+10 | 0.207276E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.195192E+09 | 0.258148E+10 | 9026996.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.268390E+09 | 0.360793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.193309E+09 | 0.258014E+10 | 10550804.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 80366777.00 | 0.885893E+09 | 0.253854E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 95718847.78 | 0.258766E+09 | 0.168450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.175970E+09 | 0.00 | 0.394662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.340923E+09 | 0.00 | 0.764614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.236584E+10 | 0.118504E+11 | 0.329104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80366777.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.348799E+09 | 0.360793E+10 | 0.782277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.394990E+09 | 0.00 | 0.889490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288993E+09 | 0.00 | 0.650791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.222969E+09 | 0.00 | 0.502111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.103732E+09 | 75711695.42 | 0.219942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 94686607.43 | 0.107334E+10 | 0.242489E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.170716E+09 | 0.225666E+10 | 8223407.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.229571E+09 | 0.307792E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.140957E+09 | 0.186981E+10 | 11924917.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 36507964.19 | 0.277310E+09 | 0.336869E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 91261141.42 | 3998690.03 | 0.204783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.203280E+09 | 0.00 | 0.457772E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.375988E+09 | 0.00 | 0.846697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.235365E+10 | 0.863474E+10 | 0.383154E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 36507964.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.394990E+09 | 0.307792E+10 | 0.889490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.338441E+09 | 0.00 | 0.781217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.234774E+09 | 0.00 | 0.541923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.178051E+09 | 15383800.66 | 0.408022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.100514E+09 | 0.323740E+09 | 0.171285E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.117833E+09 | 0.140709E+10 | 0.193005E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.198293E+09 | 0.264360E+10 | 7126925.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.268202E+09 | 0.363800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.187892E+09 | 0.252896E+10 | 8280710.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 78730435.98 | 0.871776E+09 | 0.255748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 93159716.45 | 0.250583E+09 | 0.169151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.170693E+09 | 0.00 | 0.394008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.330553E+09 | 0.00 | 0.763009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.229714E+10 | 0.116791E+11 | 0.327503E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 78730435.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.338441E+09 | 0.363800E+10 | 0.781217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.382688E+09 | 0.00 | 0.888646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.279999E+09 | 0.00 | 0.650189E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.215502E+09 | 0.00 | 0.500422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93264488.33 | 28707678.52 | 0.211322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 83525538.34 | 0.948344E+09 | 0.229052E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.174725E+09 | 0.232317E+10 | 6885958.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.230954E+09 | 0.311829E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.135755E+09 | 0.181044E+10 | 9346581.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 31614551.06 | 0.225191E+09 | 0.330846E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88459688.47 | 94986.47 | 0.205396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.196905E+09 | 0.00 | 0.457236E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.363991E+09 | 0.00 | 0.845229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.227738E+10 | 0.845425E+10 | 0.381605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31614551.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382688E+09 | 0.311829E+10 | 0.888646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.286832E+09 | 0.00 | 0.672956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.209354E+09 | 0.00 | 0.491180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.162956E+09 | 0.00 | 0.382322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 68185009.96 | 21953972.77 | 0.155931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 61491698.69 | 0.720251E+09 | 0.126586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.133083E+09 | 0.176656E+10 | 1634182.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.180470E+09 | 0.242517E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.108737E+09 | 0.144908E+10 | 2332866.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 18779285.61 | 0.155841E+09 | 0.160053E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 59206703.61 | 0.00 | 0.138909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.140995E+09 | 0.00 | 0.330797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.270235E+09 | 0.00 | 0.634015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.170033E+10 | 0.653885E+10 | 0.283517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 18779285.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.286832E+09 | 0.242517E+10 | 0.672956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.286464E+09 | 0.00 | 0.672951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.209116E+09 | 0.00 | 0.491248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.162811E+09 | 0.00 | 0.382471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 68009630.41 | 21473109.02 | 0.155806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 61529023.07 | 0.720497E+09 | 0.127409E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.133670E+09 | 0.177455E+10 | 1470660.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.180696E+09 | 0.242877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.108822E+09 | 0.145045E+10 | 2257862.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 18875221.72 | 0.156671E+09 | 0.160948E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 59248244.71 | 0.00 | 0.139184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.140813E+09 | 0.00 | 0.330793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.269873E+09 | 0.00 | 0.633977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.169993E+10 | 0.655241E+10 | 0.283564E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 18875221.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.286464E+09 | 0.242877E+10 | 0.672951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.243053E+09 | 0.00 | 0.565857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.165576E+09 | 2710230.74 | 0.384949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.126646E+09 | 20900698.02 | 0.290793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 69847025.29 | 0.251241E+09 | 0.115012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 93372812.51 | 0.114329E+10 | 93280190.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.157525E+09 | 0.209152E+10 | 2314240.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.219393E+09 | 0.295836E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.162294E+09 | 0.217658E+10 | 1909207.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 63755902.47 | 0.762277E+09 | 0.103783E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 64907712.55 | 0.244998E+09 | 0.105830E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.115930E+09 | 2077273.24 | 0.269490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.237091E+09 | 0.00 | 0.551977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.171939E+10 | 0.965394E+10 | 0.230404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63755902.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.243053E+09 | 0.295836E+10 | 0.565857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.242764E+09 | 0.00 | 0.565846E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.165443E+09 | 2881550.21 | 0.385056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.126646E+09 | 21906646.32 | 0.290934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 70147780.11 | 0.255838E+09 | 0.114970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 93584811.01 | 0.114587E+10 | 94053609.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.158147E+09 | 0.210036E+10 | 2130322.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.219613E+09 | 0.296240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.162330E+09 | 0.217788E+10 | 1862835.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 64099913.04 | 0.766395E+09 | 0.104779E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 65108488.17 | 0.247239E+09 | 0.106023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.115822E+09 | 2243920.47 | 0.269523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.236793E+09 | 0.00 | 0.551930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.172050E+10 | 0.968302E+10 | 0.230456E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 64099913.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.242764E+09 | 0.296240E+10 | 0.565846E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.262123E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.186399E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.160068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 70504964.30 | 0.00 | 0.00 | 0.00 | 3908689.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 40483643.49 | 0.00 | 0.00 | 0.00 | 0.113545E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.101162E+09 | 0.00 | 0.00 | 0.00 | 0.342601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.198945E+09 | 0.00 | 0.00 | 0.00 | 0.668211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.162179E+09 | 0.00 | 0.00 | 0.00 | 0.538918E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 56864427.34 | 0.00 | 0.00 | 0.00 | 0.185417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 37420307.35 | 0.00 | 0.00 | 0.00 | 19833597.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.112929E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.245812E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.163489E+10 | 0.00 | 0.00 | 0.00 | 0.187243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 37420307.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.262123E+09 | 0.00 | 0.00 | 0.00 | 0.668211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.300994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.226614E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.198813E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 95093620.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 31058043.55 | 0.00 | 0.00 | 0.00 | 66117833.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 82530397.98 | 0.00 | 0.00 | 0.00 | 0.280661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.163291E+09 | 0.00 | 0.00 | 0.00 | 0.549225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.111808E+09 | 0.00 | 0.00 | 0.00 | 0.372538E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 17165497.47 | 0.00 | 0.00 | 0.00 | 54855445.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 46824883.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.135886E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.274599E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.168468E+10 | 0.00 | 0.00 | 0.00 | 0.132340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17165497.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.300994E+09 | 0.00 | 0.00 | 0.00 | 0.549225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.110476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.118367E+10 | 0.00 | 0.00 | 0.00 | 2506956.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.143629E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.118367E+10 | 0.00 | 0.00 | 0.00 | 0.374889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.503311E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.479542E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.118367E+10 | 0.00 | 0.00 | 0.00 | 0.193477E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 26412881.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.118367E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.144014E+11 | 0.00 | 0.00 | 0.00 | 0.172377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.110476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.122313E+10 | 0.00 | 0.00 | 0.00 | 0.503311E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.293766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.221528E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194117E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 90687892.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 28312207.08 | 0.00 | 0.00 | 0.00 | 58314440.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 86249778.02 | 0.00 | 0.00 | 0.00 | 0.292536E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.164049E+09 | 0.00 | 0.00 | 0.00 | 0.551417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.109075E+09 | 0.00 | 0.00 | 0.00 | 0.363340E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 16650201.70 | 0.00 | 0.00 | 0.00 | 52727066.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 46397987.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.132611E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.267857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.165130E+10 | 0.00 | 0.00 | 0.00 | 0.131833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 16650201.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.293766E+09 | 0.00 | 0.00 | 0.00 | 0.551417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.220038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.164652E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144438E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65339793.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22627879.09 | 0.00 | 0.00 | 0.00 | 51946241.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 72390998.85 | 0.00 | 0.00 | 0.00 | 0.245939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.137423E+09 | 0.00 | 0.00 | 0.00 | 0.462191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 94497060.50 | 0.00 | 0.00 | 0.00 | 0.314916E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 13312577.20 | 0.00 | 0.00 | 0.00 | 43834637.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28690994.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93896958.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.199061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125637E+10 | 0.00 | 0.00 | 0.00 | 0.111883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13312577.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.220038E+09 | 0.00 | 0.00 | 0.00 | 0.462191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.219900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.164576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65253028.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22478536.00 | 0.00 | 0.00 | 0.00 | 51403955.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 72974741.57 | 0.00 | 0.00 | 0.00 | 0.247842E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.137402E+09 | 0.00 | 0.00 | 0.00 | 0.462124E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 94468691.23 | 0.00 | 0.00 | 0.00 | 0.314821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 13388020.69 | 0.00 | 0.00 | 0.00 | 44080343.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28760256.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93833036.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.198932E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125632E+10 | 0.00 | 0.00 | 0.00 | 0.112027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13388020.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.219900E+09 | 0.00 | 0.00 | 0.00 | 0.462124E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.184353E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.127749E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.108583E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 42454640.19 | 0.00 | 0.00 | 0.00 | 2328606.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 33170964.19 | 0.00 | 0.00 | 0.00 | 0.100586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 92766618.57 | 0.00 | 0.00 | 0.00 | 0.313614E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.174898E+09 | 0.00 | 0.00 | 0.00 | 0.587294E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.147684E+09 | 0.00 | 0.00 | 0.00 | 0.490652E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58483350.93 | 0.00 | 0.00 | 0.00 | 0.190812E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 23347516.75 | 0.00 | 0.00 | 0.00 | 23155433.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73278360.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.172979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.123975E+10 | 0.00 | 0.00 | 0.00 | 0.170844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23347516.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.184353E+09 | 0.00 | 0.00 | 0.00 | 0.587294E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.198337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.138640E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 46412751.31 | 0.00 | 0.00 | 0.00 | 2247589.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 36313958.34 | 0.00 | 0.00 | 0.00 | 0.110288E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.102347E+09 | 0.00 | 0.00 | 0.00 | 0.345395E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.192650E+09 | 0.00 | 0.00 | 0.00 | 0.646162E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.163331E+09 | 0.00 | 0.00 | 0.00 | 0.542235E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 65672189.01 | 0.00 | 0.00 | 0.00 | 0.214240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 25190004.61 | 0.00 | 0.00 | 0.00 | 24709102.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 81488307.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.186144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.135525E+10 | 0.00 | 0.00 | 0.00 | 0.188528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 25190004.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.198337E+09 | 0.00 | 0.00 | 0.00 | 0.646162E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.449260E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.295086E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.202547E+09 | 0.00 | 0.00 | 0.00 | 340552.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 99987592.41 | 0.00 | 0.00 | 0.00 | 0.130347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.242460E+09 | 0.00 | 0.00 | 0.00 | 0.791722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.399216E+09 | 0.00 | 0.00 | 0.00 | 0.133522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.546007E+09 | 0.00 | 0.00 | 0.00 | 0.182950E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.416480E+09 | 0.00 | 0.00 | 0.00 | 0.138252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.167187E+09 | 0.00 | 0.00 | 0.00 | 0.544723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 90271168.55 | 0.00 | 0.00 | 0.00 | 0.118169E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.200979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.442071E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.355155E+10 | 0.00 | 0.00 | 0.00 | 0.613254E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 90271168.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.546007E+09 | 0.00 | 0.00 | 0.00 | 0.182950E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.534039E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.381243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.280166E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96715569.31 | 0.00 | 0.00 | 0.00 | 14679293.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.171964E+09 | 0.00 | 0.00 | 0.00 | 0.559028E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.353322E+09 | 0.00 | 0.00 | 0.00 | 0.118337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.471227E+09 | 0.00 | 0.00 | 0.00 | 0.157989E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.310401E+09 | 0.00 | 0.00 | 0.00 | 0.103238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 60187076.33 | 0.00 | 0.00 | 0.00 | 0.197243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 78331928.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.250881E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.506078E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.349455E+10 | 0.00 | 0.00 | 0.00 | 0.456660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 60187076.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.534039E+09 | 0.00 | 0.00 | 0.00 | 0.157989E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.438554E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288087E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.196885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 94407238.10 | 0.00 | 0.00 | 0.00 | 0.124283E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.230998E+09 | 0.00 | 0.00 | 0.00 | 0.755027E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.413105E+09 | 0.00 | 0.00 | 0.00 | 0.137913E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.546847E+09 | 0.00 | 0.00 | 0.00 | 0.183094E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.409781E+09 | 0.00 | 0.00 | 0.00 | 0.135978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.166895E+09 | 0.00 | 0.00 | 0.00 | 0.543622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88086686.58 | 0.00 | 0.00 | 0.00 | 0.113827E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.196071E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.431215E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350093E+10 | 0.00 | 0.00 | 0.00 | 0.610661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 88086686.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.546847E+09 | 0.00 | 0.00 | 0.00 | 0.183094E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.520340E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.371921E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.272358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87808523.51 | 0.00 | 0.00 | 0.00 | 7615623.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.158864E+09 | 0.00 | 0.00 | 0.00 | 0.517625E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.367814E+09 | 0.00 | 0.00 | 0.00 | 0.122929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.472920E+09 | 0.00 | 0.00 | 0.00 | 0.158421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.304514E+09 | 0.00 | 0.00 | 0.00 | 0.101234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 58788472.53 | 0.00 | 0.00 | 0.00 | 0.192617E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 77417254.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.244482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.492707E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.342993E+10 | 0.00 | 0.00 | 0.00 | 0.454369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58788472.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.520340E+09 | 0.00 | 0.00 | 0.00 | 0.158421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.366670E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260968E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.193214E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 56044021.91 | 0.00 | 0.00 | 0.00 | 4634002.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.126634E+09 | 0.00 | 0.00 | 0.00 | 0.413257E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.287043E+09 | 0.00 | 0.00 | 0.00 | 0.961111E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.373112E+09 | 0.00 | 0.00 | 0.00 | 0.125121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.254011E+09 | 0.00 | 0.00 | 0.00 | 0.844934E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 50907085.77 | 0.00 | 0.00 | 0.00 | 0.167287E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 38779034.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.157665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.342261E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.250731E+10 | 0.00 | 0.00 | 0.00 | 0.364243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 38779034.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.373112E+09 | 0.00 | 0.00 | 0.00 | 0.125121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.366440E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.260853E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.193151E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 55896644.96 | 0.00 | 0.00 | 0.00 | 4523690.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.126436E+09 | 0.00 | 0.00 | 0.00 | 0.412715E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.287783E+09 | 0.00 | 0.00 | 0.00 | 0.963498E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.373164E+09 | 0.00 | 0.00 | 0.00 | 0.125138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.253913E+09 | 0.00 | 0.00 | 0.00 | 0.844606E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 51220851.65 | 0.00 | 0.00 | 0.00 | 0.168302E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 38882212.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.157550E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.342031E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.250732E+10 | 0.00 | 0.00 | 0.00 | 0.364503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 38882212.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.373164E+09 | 0.00 | 0.00 | 0.00 | 0.125138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.288518E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.181315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119948E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 58353557.61 | 0.00 | 0.00 | 0.00 | 0.100019E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196604E+09 | 0.00 | 0.00 | 0.00 | 0.643553E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.333381E+09 | 0.00 | 0.00 | 0.00 | 0.111453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.448927E+09 | 0.00 | 0.00 | 0.00 | 0.150448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.361904E+09 | 0.00 | 0.00 | 0.00 | 0.120123E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.165896E+09 | 0.00 | 0.00 | 0.00 | 0.540832E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 62020542.73 | 0.00 | 0.00 | 0.00 | 0.132360E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111533E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283773E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.261217E+10 | 0.00 | 0.00 | 0.00 | 0.523700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58353557.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.448927E+09 | 0.00 | 0.00 | 0.00 | 0.150448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.288331E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.181285E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119936E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 58931187.84 | 0.00 | 0.00 | 0.00 | 0.101983E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196570E+09 | 0.00 | 0.00 | 0.00 | 0.643455E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.334113E+09 | 0.00 | 0.00 | 0.00 | 0.111689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.448976E+09 | 0.00 | 0.00 | 0.00 | 0.150464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.361771E+09 | 0.00 | 0.00 | 0.00 | 0.120078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.166017E+09 | 0.00 | 0.00 | 0.00 | 0.541218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 61979767.45 | 0.00 | 0.00 | 0.00 | 0.132163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111481E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283582E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.261297E+10 | 0.00 | 0.00 | 0.00 | 0.524113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58931187.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.448976E+09 | 0.00 | 0.00 | 0.00 | 0.150464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.348799E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.242556E+09 | 0.00 | 0.00 | 0.00 | 671813.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.187142E+09 | 0.00 | 0.00 | 0.00 | 11858347.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.109513E+09 | 0.00 | 0.00 | 0.00 | 96427738.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.127956E+09 | 0.00 | 0.00 | 0.00 | 0.389242E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.195192E+09 | 0.00 | 0.00 | 0.00 | 0.654030E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.268390E+09 | 0.00 | 0.00 | 0.00 | 0.902077E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.193309E+09 | 0.00 | 0.00 | 0.00 | 0.641235E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 80366777.00 | 0.00 | 0.00 | 0.00 | 0.224777E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 95718847.78 | 0.00 | 0.00 | 0.00 | 66586167.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.175970E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.340923E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.236584E+10 | 0.00 | 0.00 | 0.00 | 0.298690E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 80366777.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.348799E+09 | 0.00 | 0.00 | 0.00 | 0.902077E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.394990E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.288993E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.222969E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.103732E+09 | 0.00 | 0.00 | 0.00 | 19757556.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 94686607.43 | 0.00 | 0.00 | 0.00 | 0.276480E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.170716E+09 | 0.00 | 0.00 | 0.00 | 0.573142E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.229571E+09 | 0.00 | 0.00 | 0.00 | 0.772289E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.140957E+09 | 0.00 | 0.00 | 0.00 | 0.468118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 36507964.19 | 0.00 | 0.00 | 0.00 | 70675036.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 91261141.42 | 0.00 | 0.00 | 0.00 | 1051576.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.203280E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.375988E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.235365E+10 | 0.00 | 0.00 | 0.00 | 0.218151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 36507964.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.394990E+09 | 0.00 | 0.00 | 0.00 | 0.772289E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.338441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.234774E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.178051E+09 | 0.00 | 0.00 | 0.00 | 4093643.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.100514E+09 | 0.00 | 0.00 | 0.00 | 84220112.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.117833E+09 | 0.00 | 0.00 | 0.00 | 0.358973E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.198293E+09 | 0.00 | 0.00 | 0.00 | 0.663536E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.268202E+09 | 0.00 | 0.00 | 0.00 | 0.900456E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.187892E+09 | 0.00 | 0.00 | 0.00 | 0.623293E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 78730435.98 | 0.00 | 0.00 | 0.00 | 0.220185E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 93159716.45 | 0.00 | 0.00 | 0.00 | 64240319.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.170693E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.330553E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.229714E+10 | 0.00 | 0.00 | 0.00 | 0.291900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 78730435.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.338441E+09 | 0.00 | 0.00 | 0.00 | 0.900456E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.382688E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.279999E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.215502E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93264488.33 | 0.00 | 0.00 | 0.00 | 7480032.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 83525538.34 | 0.00 | 0.00 | 0.00 | 0.243018E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.174725E+09 | 0.00 | 0.00 | 0.00 | 0.585602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.230954E+09 | 0.00 | 0.00 | 0.00 | 0.775925E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.135755E+09 | 0.00 | 0.00 | 0.00 | 0.450979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 31614551.06 | 0.00 | 0.00 | 0.00 | 57079141.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88459688.47 | 0.00 | 0.00 | 0.00 | 25071.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.196905E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.363991E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.227738E+10 | 0.00 | 0.00 | 0.00 | 0.212011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31614551.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382688E+09 | 0.00 | 0.00 | 0.00 | 0.775925E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.286832E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.209354E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.162956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 68185009.96 | 0.00 | 0.00 | 0.00 | 5720011.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 61491698.69 | 0.00 | 0.00 | 0.00 | 0.185489E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.133083E+09 | 0.00 | 0.00 | 0.00 | 0.447905E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.180470E+09 | 0.00 | 0.00 | 0.00 | 0.607333E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.108737E+09 | 0.00 | 0.00 | 0.00 | 0.362434E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 18779285.61 | 0.00 | 0.00 | 0.00 | 39460002.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 59206703.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.140995E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.270235E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.170033E+10 | 0.00 | 0.00 | 0.00 | 0.164834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 18779285.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.286832E+09 | 0.00 | 0.00 | 0.00 | 0.607333E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.286464E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.209116E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.162811E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 68009630.41 | 0.00 | 0.00 | 0.00 | 5596867.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 61529023.07 | 0.00 | 0.00 | 0.00 | 0.185512E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.133670E+09 | 0.00 | 0.00 | 0.00 | 0.449820E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.180696E+09 | 0.00 | 0.00 | 0.00 | 0.608063E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.108822E+09 | 0.00 | 0.00 | 0.00 | 0.362715E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 18875221.72 | 0.00 | 0.00 | 0.00 | 39673916.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 59248244.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.140813E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.269873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.169993E+10 | 0.00 | 0.00 | 0.00 | 0.165138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 18875221.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.286464E+09 | 0.00 | 0.00 | 0.00 | 0.608063E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.243053E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.165576E+09 | 0.00 | 0.00 | 0.00 | 725780.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.126646E+09 | 0.00 | 0.00 | 0.00 | 5545070.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 69847025.29 | 0.00 | 0.00 | 0.00 | 65537134.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 93372812.51 | 0.00 | 0.00 | 0.00 | 0.293449E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.157525E+09 | 0.00 | 0.00 | 0.00 | 0.528733E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.219393E+09 | 0.00 | 0.00 | 0.00 | 0.737559E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.162294E+09 | 0.00 | 0.00 | 0.00 | 0.539470E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 63755902.47 | 0.00 | 0.00 | 0.00 | 0.193156E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 64907712.55 | 0.00 | 0.00 | 0.00 | 62846351.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.115930E+09 | 0.00 | 0.00 | 0.00 | 556091.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.237091E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.171939E+10 | 0.00 | 0.00 | 0.00 | 0.242758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63755902.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.243053E+09 | 0.00 | 0.00 | 0.00 | 0.737559E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.242764E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.165443E+09 | 0.00 | 0.00 | 0.00 | 771469.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.126646E+09 | 0.00 | 0.00 | 0.00 | 5813542.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 70147780.11 | 0.00 | 0.00 | 0.00 | 66728956.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 93584811.01 | 0.00 | 0.00 | 0.00 | 0.294023E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.158147E+09 | 0.00 | 0.00 | 0.00 | 0.530759E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.219613E+09 | 0.00 | 0.00 | 0.00 | 0.738264E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.162330E+09 | 0.00 | 0.00 | 0.00 | 0.539582E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 64099913.04 | 0.00 | 0.00 | 0.00 | 0.194143E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 65108488.17 | 0.00 | 0.00 | 0.00 | 63398382.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.115822E+09 | 0.00 | 0.00 | 0.00 | 600382.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.236793E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.172050E+10 | 0.00 | 0.00 | 0.00 | 0.243408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 64099913.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.242764E+09 | 0.00 | 0.00 | 0.00 | 0.738264E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 10752474.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306400E+10 | 0.00 | 0.00 | 0.35 |
| February | 80076961.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230665E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.171904E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204067E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.432440E+09 | 1361885.11 | 0.00 | 3763.57 | 23911.57 | 0.938983E+09 | 660250.15 | 0.00 | 0.35 |
| May | 0.593683E+09 | 25841250.17 | 0.00 | 500008.85 | 727096.58 | 79288528.80 | 0.121648E+09 | 0.00 | 0.35 |
| June | 0.315732E+09 | 0.163157E+09 | 0.00 | 869445.55 | 0.00 | 0.00 | 0.152364E+09 | 0.00 | 0.36 |
| July | 26385866.18 | 0.270486E+09 | 0.00 | 1797218.52 | 0.00 | 0.00 | 0.288630E+09 | 0.00 | 0.36 |
| August | 72793231.14 | 0.122061E+09 | 0.00 | 2384425.63 | 0.00 | 0.00 | 0.353481E+09 | 0.00 | 0.36 |
| September | 0.503463E+09 | 5586821.57 | 0.00 | 1847186.18 | 0.00 | 0.00 | 0.388121E+09 | 0.00 | 0.36 |
| October | 0.802619E+09 | 0.00 | 0.00 | 244007.54 | 0.00 | 0.484678E+09 | 65614141.95 | 0.00 | 0.35 |
| November | 0.214746E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160082E+10 | 0.00 | 0.00 | 0.35 |
| December | 9119027.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288308E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.323371E+10 | 0.588494E+09 | 0.00 | 7646055.85 | 751008.15 | 0.133982E+11 | 0.137052E+10 | 0.00 | 0.35 |
| Minimum of Months | 9119027.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.802619E+09 | 0.270486E+09 | 0.00 | 2384425.63 | 727096.58 | 0.306400E+10 | 0.388121E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307480E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238717E+10 | 0.00 | 0.00 | 0.35 |
| March | 11021344.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220245E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.136206E+09 | 0.00 | 0.00 | 0.00 | 2056535.38 | 0.121833E+10 | 0.00 | 0.00 | 0.35 |
| May | 0.568492E+09 | 21720934.38 | 0.00 | 246700.19 | 1777482.67 | 0.138770E+09 | 58835310.47 | 0.00 | 0.35 |
| June | 0.339980E+09 | 0.155887E+09 | 0.00 | 642317.10 | 47120.05 | 0.00 | 0.125914E+09 | 0.00 | 0.36 |
| July | 39179695.36 | 0.249515E+09 | 0.00 | 1555662.34 | 0.00 | 0.00 | 0.286551E+09 | 0.00 | 0.36 |
| August | 0.107019E+09 | 0.103973E+09 | 0.00 | 1684586.17 | 0.00 | 0.00 | 0.343053E+09 | 0.00 | 0.36 |
| September | 0.692605E+09 | 3869823.03 | 0.00 | 613616.90 | 0.00 | 0.00 | 0.170290E+09 | 0.00 | 0.35 |
| October | 0.610418E+09 | 0.00 | 0.00 | 0.00 | 16189.75 | 0.689428E+09 | 0.00 | 0.00 | 0.35 |
| November | 9849627.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180492E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289217E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.251477E+10 | 0.534966E+09 | 0.00 | 4742882.69 | 3897327.85 | 0.144080E+11 | 0.984644E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.692605E+09 | 0.249515E+09 | 0.00 | 1684586.17 | 2056535.38 | 0.307480E+10 | 0.343053E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.716445E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.334068E+10 | 0.00 | 0.00 | 0.50 |
| February | 0.118455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193685E+10 | 0.00 | 0.00 | 0.51 |
| March | 0.152101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136240E+10 | 0.00 | 0.00 | 0.51 |
| April | 0.154404E+10 | 0.00 | 0.00 | 5886.68 | 2355230.77 | 0.293097E+09 | 17324558.97 | 0.00 | 0.51 |
| May | 0.114934E+10 | 22792258.19 | 0.00 | 350660.59 | 2370493.26 | 13146468.70 | 92919690.88 | 0.00 | 0.52 |
| June | 0.751345E+09 | 0.117687E+09 | 0.00 | 996304.12 | 23859242.92 | 0.00 | 0.105068E+09 | 0.00 | 0.53 |
| July | 0.755840E+09 | 0.156716E+09 | 0.00 | 1274943.30 | 29094982.79 | 0.00 | 48202101.09 | 0.00 | 0.53 |
| August | 0.817819E+09 | 0.127923E+09 | 0.00 | 1307027.22 | 14722546.20 | 0.00 | 94396973.50 | 0.00 | 0.53 |
| September | 0.123209E+10 | 6302296.28 | 0.00 | 1141007.65 | 298470.71 | 0.00 | 0.238198E+09 | 0.00 | 0.52 |
| October | 0.170477E+10 | 0.00 | 0.00 | 190149.80 | 0.00 | 0.144078E+09 | 0.110061E+09 | 0.00 | 0.51 |
| November | 0.158728E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.766220E+09 | 0.00 | 0.00 | 0.51 |
| December | 0.108767E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.270667E+10 | 0.00 | 0.00 | 0.50 |
| Annual Sum or Average | 0.140522E+11 | 0.431421E+09 | 0.00 | 5265979.37 | 72700966.65 | 0.105631E+11 | 0.706171E+09 | 0.00 | 0.52 |
| Minimum of Months | 0.716445E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 |
| Maximum of Months | 0.170477E+10 | 0.156716E+09 | 0.00 | 1307027.22 | 29094982.79 | 0.334068E+10 | 0.238198E+09 | 0.00 | 0.53 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307478E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238716E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221348E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.130577E+09 | 0.00 | 0.00 | 0.00 | 2301200.46 | 0.122273E+10 | 0.00 | 0.00 | 0.35 |
| May | 0.579900E+09 | 21630812.09 | 0.00 | 214827.81 | 1562873.76 | 0.132253E+09 | 51284639.25 | 0.00 | 0.35 |
| June | 0.330828E+09 | 0.157187E+09 | 0.00 | 776732.12 | 0.00 | 0.00 | 0.141690E+09 | 0.00 | 0.36 |
| July | 60489089.05 | 0.251227E+09 | 0.00 | 1618073.83 | 0.00 | 0.00 | 0.266564E+09 | 0.00 | 0.36 |
| August | 0.113643E+09 | 0.105600E+09 | 0.00 | 1673109.90 | 0.00 | 0.00 | 0.342229E+09 | 0.00 | 0.36 |
| September | 0.678852E+09 | 4218117.31 | 0.00 | 585555.97 | 0.00 | 0.00 | 0.186535E+09 | 0.00 | 0.35 |
| October | 0.580580E+09 | 0.00 | 0.00 | 0.00 | 5047.59 | 0.718061E+09 | 0.00 | 0.00 | 0.35 |
| November | 9940968.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180480E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289214E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.248481E+10 | 0.539863E+09 | 0.00 | 4868299.62 | 3869121.81 | 0.144454E+11 | 0.988303E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.678852E+09 | 0.251227E+09 | 0.00 | 1673109.90 | 2301200.46 | 0.307478E+10 | 0.342229E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.308022E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239221E+10 | 0.00 | 0.00 | 0.35 |
| March | 14902291.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220334E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.271316E+09 | 0.00 | 0.00 | 0.00 | 2457144.24 | 0.108781E+10 | 0.00 | 0.00 | 0.35 |
| May | 0.632203E+09 | 20344150.52 | 0.00 | 289527.09 | 2760062.47 | 57129770.56 | 88640511.30 | 0.00 | 0.35 |
| June | 0.311455E+09 | 0.152401E+09 | 0.00 | 708381.23 | 0.00 | 0.00 | 0.169554E+09 | 0.00 | 0.36 |
| July | 16096380.75 | 0.236708E+09 | 0.00 | 1554692.75 | 0.00 | 0.00 | 0.314465E+09 | 0.00 | 0.36 |
| August | 57449635.24 | 97715239.60 | 0.00 | 1740498.56 | 0.00 | 0.00 | 0.400839E+09 | 0.00 | 0.36 |
| September | 0.670334E+09 | 3632297.80 | 0.00 | 605205.02 | 0.00 | 0.00 | 0.219474E+09 | 0.00 | 0.36 |
| October | 0.104030E+10 | 0.00 | 0.00 | 0.00 | 21103.99 | 0.267900E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.186300E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163479E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289804E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.320036E+10 | 0.510800E+09 | 0.00 | 4898304.65 | 5238310.71 | 0.136214E+11 | 0.119297E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.104030E+10 | 0.236708E+09 | 0.00 | 1740498.56 | 2760062.47 | 0.308022E+10 | 0.400839E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.308022E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239221E+10 | 0.00 | 0.00 | 0.35 |
| March | 12789804.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220546E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.270397E+09 | 0.00 | 0.00 | 0.00 | 2465301.58 | 0.108870E+10 | 0.00 | 0.00 | 0.35 |
| May | 0.631326E+09 | 20333430.97 | 0.00 | 288660.52 | 2744436.74 | 57663631.13 | 88682228.28 | 0.00 | 0.35 |
| June | 0.308939E+09 | 0.152496E+09 | 0.00 | 726893.30 | 0.00 | 0.00 | 0.172638E+09 | 0.00 | 0.36 |
| July | 17474195.18 | 0.236778E+09 | 0.00 | 1549731.22 | 0.00 | 0.00 | 0.313187E+09 | 0.00 | 0.36 |
| August | 57399226.59 | 97844600.60 | 0.00 | 1735115.59 | 0.00 | 0.00 | 0.401155E+09 | 0.00 | 0.36 |
| September | 0.666929E+09 | 3645623.20 | 0.00 | 610032.63 | 0.00 | 0.00 | 0.223012E+09 | 0.00 | 0.36 |
| October | 0.104063E+10 | 0.00 | 0.00 | 0.00 | 20318.37 | 0.267451E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.186725E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163436E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289804E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.319261E+10 | 0.511097E+09 | 0.00 | 4910433.26 | 5230056.68 | 0.136241E+11 | 0.119867E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.104063E+10 | 0.236778E+09 | 0.00 | 1735115.59 | 2744436.74 | 0.308022E+10 | 0.401155E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 91682554.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298862E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.263698E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212825E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.381832E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183533E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.768410E+09 | 1298407.66 | 0.00 | 1677.55 | 10969.69 | 0.613534E+09 | 597307.51 | 0.00 | 0.35 |
| May | 0.642487E+09 | 25529348.72 | 0.00 | 548626.83 | 797113.38 | 20769303.16 | 0.149405E+09 | 0.00 | 0.35 |
| June | 0.274000E+09 | 0.161240E+09 | 0.00 | 985830.46 | 0.00 | 0.00 | 0.207293E+09 | 0.00 | 0.36 |
| July | 7735626.25 | 0.261929E+09 | 0.00 | 1815755.95 | 0.00 | 0.00 | 0.308925E+09 | 0.00 | 0.36 |
| August | 32499269.05 | 0.118630E+09 | 0.00 | 2468847.34 | 0.00 | 0.00 | 0.395186E+09 | 0.00 | 0.36 |
| September | 0.399630E+09 | 5576423.80 | 0.00 | 2125195.55 | 0.00 | 0.00 | 0.513516E+09 | 0.00 | 0.36 |
| October | 0.122288E+10 | 0.00 | 0.00 | 330234.52 | 0.00 | 40654729.53 | 0.115340E+09 | 0.00 | 0.35 |
| November | 0.735725E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108707E+10 | 0.00 | 0.00 | 0.35 |
| December | 61194772.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.283695E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.488178E+10 | 0.574204E+09 | 0.00 | 8276168.20 | 808083.06 | 0.115512E+11 | 0.169026E+10 | 0.00 | 0.35 |
| Minimum of Months | 7735626.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.122288E+10 | 0.261929E+09 | 0.00 | 2468847.34 | 797113.38 | 0.298862E+10 | 0.513516E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 51120397.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302916E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.192452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219932E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.303347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191341E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.709381E+09 | 1285027.82 | 0.00 | 1533.06 | 20341.50 | 0.671662E+09 | 531567.60 | 0.00 | 0.35 |
| May | 0.614845E+09 | 25871736.43 | 0.00 | 617204.61 | 749551.63 | 34692860.07 | 0.164203E+09 | 0.00 | 0.35 |
| June | 0.251000E+09 | 0.166291E+09 | 0.00 | 1136311.67 | 0.00 | 0.00 | 0.227631E+09 | 0.00 | 0.36 |
| July | 6232144.57 | 0.273180E+09 | 0.00 | 1989924.57 | 0.00 | 0.00 | 0.300649E+09 | 0.00 | 0.36 |
| August | 23011770.97 | 0.122881E+09 | 0.00 | 2720881.26 | 0.00 | 0.00 | 0.393105E+09 | 0.00 | 0.36 |
| September | 0.377703E+09 | 5807330.14 | 0.00 | 2363691.77 | 0.00 | 0.00 | 0.535360E+09 | 0.00 | 0.36 |
| October | 0.116495E+10 | 0.00 | 0.00 | 355330.00 | 0.00 | 87988329.88 | 0.127699E+09 | 0.00 | 0.35 |
| November | 0.551306E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127106E+10 | 0.00 | 0.00 | 0.35 |
| December | 45206144.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.285293E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.429055E+10 | 0.595315E+09 | 0.00 | 9184876.94 | 769893.13 | 0.120602E+11 | 0.174918E+10 | 0.00 | 0.35 |
| Minimum of Months | 6232144.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.116495E+10 | 0.273180E+09 | 0.00 | 2720881.26 | 749551.63 | 0.302916E+10 | 0.535360E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.352946E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.578684E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.854225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392085E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.152091E+10 | 0.00 | 0.00 | 68644.84 | 0.00 | 0.290899E+10 | 21113898.53 | 0.00 | 0.35 |
| April | 0.176623E+10 | 3645492.38 | 0.00 | 1347853.85 | 0.00 | 0.806995E+09 | 0.294152E+09 | 0.00 | 0.35 |
| May | 0.842726E+09 | 59308509.33 | 0.00 | 5152622.79 | 0.00 | 0.00 | 0.878311E+09 | 0.00 | 0.35 |
| June | 0.151861E+09 | 0.367496E+09 | 0.00 | 5342274.03 | 0.00 | 0.00 | 0.772828E+09 | 0.00 | 0.36 |
| July | 2706264.37 | 0.587882E+09 | 0.00 | 4851232.37 | 0.00 | 0.00 | 0.580644E+09 | 0.00 | 0.36 |
| August | 0.101081E+09 | 0.257996E+09 | 0.00 | 5770766.77 | 0.00 | 0.00 | 0.723087E+09 | 0.00 | 0.36 |
| September | 0.920170E+09 | 12696008.24 | 0.00 | 4979880.24 | 0.00 | 0.00 | 0.860133E+09 | 0.00 | 0.36 |
| October | 0.175161E+10 | 0.00 | 0.00 | 1280877.84 | 0.00 | 0.744356E+09 | 0.237227E+09 | 0.00 | 0.35 |
| November | 0.851587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.277653E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.191693E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558212E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.930775E+10 | 0.128902E+10 | 0.00 | 28794152.72 | 0.00 | 0.225267E+11 | 0.436750E+10 | 0.00 | 0.35 |
| Minimum of Months | 2706264.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.176623E+10 | 0.587882E+09 | 0.00 | 5770766.77 | 0.00 | 0.578684E+10 | 0.878311E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.614001E+10 | 0.00 | 0.00 | 0.35 |
| February | 58115148.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.470749E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.433414E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.398795E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.144633E+10 | 3058860.90 | 0.00 | 31460.96 | 11882.73 | 0.131663E+10 | 8633181.90 | 0.00 | 0.35 |
| May | 0.102156E+10 | 54586217.02 | 0.00 | 3628451.94 | 0.00 | 3730555.28 | 0.669935E+09 | 0.00 | 0.35 |
| June | 0.161858E+09 | 0.357726E+09 | 0.00 | 4883557.62 | 0.00 | 0.00 | 0.765016E+09 | 0.00 | 0.36 |
| July | 12106238.13 | 0.554099E+09 | 0.00 | 4559860.33 | 0.00 | 0.00 | 0.582373E+09 | 0.00 | 0.36 |
| August | 0.126635E+09 | 0.226471E+09 | 0.00 | 4614468.98 | 0.00 | 0.00 | 0.731189E+09 | 0.00 | 0.36 |
| September | 0.123411E+10 | 8684949.34 | 0.00 | 2139413.15 | 0.00 | 0.00 | 0.519625E+09 | 0.00 | 0.36 |
| October | 0.153303E+10 | 0.00 | 0.00 | 559.85 | 0.00 | 0.109606E+10 | 1439260.75 | 0.00 | 0.35 |
| November | 0.191048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342937E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577389E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.621820E+10 | 0.120463E+10 | 0.00 | 19857772.83 | 11882.73 | 0.264551E+11 | 0.327821E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.153303E+10 | 0.554099E+09 | 0.00 | 4883557.62 | 11882.73 | 0.614001E+10 | 0.765016E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.384961E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.575466E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.851236E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392197E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.164051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.280744E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.182565E+10 | 3452071.86 | 0.00 | 1232864.54 | 0.00 | 0.741215E+09 | 0.309379E+09 | 0.00 | 0.35 |
| May | 0.849528E+09 | 59337884.22 | 0.00 | 5031189.75 | 0.00 | 0.00 | 0.875102E+09 | 0.00 | 0.35 |
| June | 0.130494E+09 | 0.368924E+09 | 0.00 | 5987523.37 | 0.00 | 0.00 | 0.795499E+09 | 0.00 | 0.36 |
| July | 19992310.08 | 0.590151E+09 | 0.00 | 5169249.10 | 0.00 | 0.00 | 0.566535E+09 | 0.00 | 0.36 |
| August | 95668401.74 | 0.259171E+09 | 0.00 | 5881925.09 | 0.00 | 0.00 | 0.736677E+09 | 0.00 | 0.36 |
| September | 0.917087E+09 | 13127566.97 | 0.00 | 5000532.70 | 0.00 | 0.00 | 0.866422E+09 | 0.00 | 0.36 |
| October | 0.173606E+10 | 0.00 | 0.00 | 1184268.78 | 0.00 | 0.759816E+09 | 0.233558E+09 | 0.00 | 0.35 |
| November | 0.881926E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274599E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.177161E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.559659E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.951026E+10 | 0.129416E+10 | 0.00 | 29487553.33 | 0.00 | 0.223277E+11 | 0.438317E+10 | 0.00 | 0.35 |
| Minimum of Months | 19992310.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.182565E+10 | 0.590151E+09 | 0.00 | 5987523.37 | 0.00 | 0.575466E+10 | 0.875102E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.613996E+10 | 0.00 | 0.00 | 0.35 |
| February | 11571339.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.475402E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.451895E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.396639E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.150974E+10 | 2785528.33 | 0.00 | 17129.72 | 5624.91 | 0.125509E+10 | 7177874.57 | 0.00 | 0.35 |
| May | 0.994064E+09 | 54692660.04 | 0.00 | 3522409.56 | 0.00 | 0.00 | 0.706473E+09 | 0.00 | 0.35 |
| June | 0.149770E+09 | 0.359288E+09 | 0.00 | 5544928.75 | 0.00 | 0.00 | 0.777693E+09 | 0.00 | 0.36 |
| July | 21729385.49 | 0.557207E+09 | 0.00 | 4841097.02 | 0.00 | 0.00 | 0.576334E+09 | 0.00 | 0.36 |
| August | 0.122191E+09 | 0.228597E+09 | 0.00 | 4701030.76 | 0.00 | 0.00 | 0.745238E+09 | 0.00 | 0.36 |
| September | 0.120915E+10 | 9364818.50 | 0.00 | 2056967.64 | 0.00 | 0.00 | 0.550285E+09 | 0.00 | 0.36 |
| October | 0.154164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108408E+10 | 0.00 | 0.00 | 0.35 |
| November | 0.185059E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343527E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577381E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.619681E+10 | 0.121194E+10 | 0.00 | 20683563.45 | 5624.91 | 0.264086E+11 | 0.336320E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.154164E+10 | 0.557207E+09 | 0.00 | 5544928.75 | 5624.91 | 0.613996E+10 | 0.777693E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 61750003.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609136E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.347364E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.443028E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.129013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314071E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.220415E+10 | 2504501.40 | 0.00 | 11002.70 | 230863.31 | 0.572361E+09 | 4024481.54 | 0.00 | 0.35 |
| May | 0.935251E+09 | 51753265.40 | 0.00 | 3190162.81 | 0.00 | 0.00 | 0.790220E+09 | 0.00 | 0.35 |
| June | 51787449.63 | 0.340741E+09 | 0.00 | 4792731.42 | 0.00 | 0.00 | 0.885454E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.516883E+09 | 0.00 | 4220461.07 | 0.00 | 0.00 | 0.609772E+09 | 0.00 | 0.36 |
| August | 42343484.66 | 0.209660E+09 | 0.00 | 4584701.74 | 0.00 | 0.00 | 0.828968E+09 | 0.00 | 0.36 |
| September | 0.110981E+10 | 7878612.46 | 0.00 | 2199348.25 | 0.00 | 0.00 | 0.699994E+09 | 0.00 | 0.36 |
| October | 0.252291E+10 | 0.00 | 0.00 | 591.49 | 0.00 | 0.140811E+09 | 2265339.79 | 0.00 | 0.35 |
| November | 0.111233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252341E+10 | 0.00 | 0.00 | 0.35 |
| December | 76008887.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.571211E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.975384E+10 | 0.112942E+10 | 0.00 | 18998999.48 | 230863.31 | 0.226110E+11 | 0.382070E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.252291E+10 | 0.516883E+09 | 0.00 | 4792731.42 | 230863.31 | 0.609136E+10 | 0.885454E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 59899564.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609321E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.347252E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.443039E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.129044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314029E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.221305E+10 | 2501460.98 | 0.00 | 10569.22 | 228478.52 | 0.563862E+09 | 4029986.71 | 0.00 | 0.35 |
| May | 0.934322E+09 | 51758884.68 | 0.00 | 3189881.19 | 0.00 | 0.00 | 0.791692E+09 | 0.00 | 0.35 |
| June | 51177127.59 | 0.340802E+09 | 0.00 | 4817548.02 | 0.00 | 0.00 | 0.886180E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.516984E+09 | 0.00 | 4222639.28 | 0.00 | 0.00 | 0.610036E+09 | 0.00 | 0.36 |
| August | 41889204.61 | 0.209854E+09 | 0.00 | 4583400.90 | 0.00 | 0.00 | 0.830012E+09 | 0.00 | 0.36 |
| September | 0.110539E+10 | 7910786.90 | 0.00 | 2213873.99 | 0.00 | 0.00 | 0.704481E+09 | 0.00 | 0.36 |
| October | 0.252548E+10 | 0.00 | 0.00 | 442.21 | 0.00 | 0.137912E+09 | 1933530.19 | 0.00 | 0.35 |
| November | 0.111273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252301E+10 | 0.00 | 0.00 | 0.35 |
| December | 76008893.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.571211E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.975764E+10 | 0.112981E+10 | 0.00 | 19038354.81 | 228478.52 | 0.226008E+11 | 0.382836E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.252548E+10 | 0.516984E+09 | 0.00 | 4817548.02 | 228478.52 | 0.609321E+10 | 0.886180E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.143207E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.472134E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.202659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276835E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.295389E+10 | 0.00 | 0.00 | 3064.55 | 0.00 | 0.150793E+10 | 10115210.15 | 0.00 | 0.35 |
| April | 0.241957E+10 | 3494588.54 | 0.00 | 1179999.41 | 0.00 | 0.148272E+09 | 0.350071E+09 | 0.00 | 0.35 |
| May | 0.679120E+09 | 57425023.27 | 0.00 | 4854981.75 | 0.00 | 0.00 | 0.107824E+10 | 0.00 | 0.36 |
| June | 57989168.40 | 0.353539E+09 | 0.00 | 5187965.93 | 0.00 | 0.00 | 0.875633E+09 | 0.00 | 0.36 |
| July | 289642.91 | 0.559778E+09 | 0.00 | 4548575.31 | 0.00 | 0.00 | 0.594656E+09 | 0.00 | 0.36 |
| August | 34916827.11 | 0.247692E+09 | 0.00 | 5768654.04 | 0.00 | 0.00 | 0.794818E+09 | 0.00 | 0.36 |
| September | 0.643562E+09 | 12350073.27 | 0.00 | 5512315.60 | 0.00 | 0.00 | 0.117986E+10 | 0.00 | 0.36 |
| October | 0.229912E+10 | 0.00 | 0.00 | 1685404.08 | 0.00 | 36933098.88 | 0.463258E+09 | 0.00 | 0.35 |
| November | 0.217529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147859E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.966292E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.482198E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.156887E+11 | 0.123428E+10 | 0.00 | 28740960.67 | 0.00 | 0.154834E+11 | 0.534665E+10 | 0.00 | 0.35 |
| Minimum of Months | 289642.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.295389E+10 | 0.559778E+09 | 0.00 | 5768654.04 | 0.00 | 0.482198E+10 | 0.117986E+10 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.143522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.471820E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.202536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276951E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.295119E+10 | 0.00 | 0.00 | 2968.67 | 0.00 | 0.151055E+10 | 10115430.29 | 0.00 | 0.35 |
| April | 0.240932E+10 | 3492247.82 | 0.00 | 1197081.43 | 0.00 | 0.154588E+09 | 0.354746E+09 | 0.00 | 0.35 |
| May | 0.677368E+09 | 57423236.89 | 0.00 | 4852028.63 | 0.00 | 0.00 | 0.108025E+10 | 0.00 | 0.36 |
| June | 57581002.00 | 0.353581E+09 | 0.00 | 5204874.81 | 0.00 | 0.00 | 0.876195E+09 | 0.00 | 0.36 |
| July | 290023.57 | 0.559793E+09 | 0.00 | 4548909.22 | 0.00 | 0.00 | 0.594903E+09 | 0.00 | 0.36 |
| August | 34608027.17 | 0.247791E+09 | 0.00 | 5768544.72 | 0.00 | 0.00 | 0.795634E+09 | 0.00 | 0.36 |
| September | 0.648229E+09 | 12366126.76 | 0.00 | 5510902.76 | 0.00 | 0.00 | 0.117507E+10 | 0.00 | 0.36 |
| October | 0.230003E+10 | 0.00 | 0.00 | 1677154.16 | 0.00 | 36933095.69 | 0.461747E+09 | 0.00 | 0.35 |
| November | 0.217394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148001E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.967675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.482060E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.156808E+11 | 0.123445E+10 | 0.00 | 28762464.40 | 0.00 | 0.154904E+11 | 0.534867E+10 | 0.00 | 0.35 |
| Minimum of Months | 290023.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.295119E+10 | 0.559793E+09 | 0.00 | 5768544.72 | 0.00 | 0.482060E+10 | 0.117507E+10 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 82094249.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298349E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.179491E+09 | 0.00 | 0.00 | 22107.90 | 0.00 | 0.219227E+10 | 13454618.72 | 0.00 | 0.35 |
| March | 0.312336E+09 | 0.00 | 0.00 | 320592.15 | 0.00 | 0.185035E+10 | 60810172.27 | 0.00 | 0.35 |
| April | 0.412611E+09 | 1855719.33 | 0.00 | 898338.95 | 0.00 | 0.862946E+09 | 0.123702E+09 | 0.00 | 0.35 |
| May | 0.463510E+09 | 29831968.21 | 0.00 | 1933114.17 | 0.00 | 0.107362E+09 | 0.229026E+09 | 0.00 | 0.35 |
| June | 0.272017E+09 | 0.179764E+09 | 0.00 | 1866253.40 | 0.00 | 3712979.06 | 0.170053E+09 | 0.00 | 0.36 |
| July | 0.164917E+09 | 0.282615E+09 | 0.00 | 1587829.16 | 69736.07 | 0.00 | 0.146358E+09 | 0.00 | 0.36 |
| August | 0.250973E+09 | 0.126919E+09 | 0.00 | 1746381.03 | 16069.45 | 5482151.32 | 0.171448E+09 | 0.00 | 0.36 |
| September | 0.492855E+09 | 6338466.46 | 0.00 | 1715786.10 | 0.00 | 0.144609E+09 | 0.181707E+09 | 0.00 | 0.35 |
| October | 0.375706E+09 | 0.00 | 0.00 | 684540.53 | 0.00 | 0.854807E+09 | 90870346.88 | 0.00 | 0.35 |
| November | 0.140825E+09 | 0.00 | 0.00 | 3831.80 | 0.00 | 0.166506E+10 | 3537881.87 | 0.00 | 0.35 |
| December | 43764159.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.283848E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.319110E+10 | 0.627324E+09 | 0.00 | 10778775.17 | 85805.52 | 0.135086E+11 | 0.119097E+10 | 0.00 | 0.35 |
| Minimum of Months | 43764159.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.492855E+09 | 0.282615E+09 | 0.00 | 1933114.17 | 69736.07 | 0.298349E+10 | 0.229026E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306580E+10 | 0.00 | 0.00 | 0.35 |
| February | 5087030.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237391E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.106386E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210107E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.312205E+09 | 1650119.92 | 0.00 | 132797.34 | 329.55 | 0.103018E+10 | 29686302.48 | 0.00 | 0.35 |
| May | 0.482901E+09 | 27688934.44 | 0.00 | 1288843.22 | 0.00 | 0.128389E+09 | 0.176729E+09 | 0.00 | 0.35 |
| June | 0.277617E+09 | 0.176422E+09 | 0.00 | 1618502.41 | 0.00 | 1801626.15 | 0.167070E+09 | 0.00 | 0.36 |
| July | 0.163614E+09 | 0.268956E+09 | 0.00 | 1442584.20 | 18027.62 | 0.00 | 0.151289E+09 | 0.00 | 0.36 |
| August | 0.272988E+09 | 0.111965E+09 | 0.00 | 1303649.85 | 58440.28 | 7445374.30 | 0.154542E+09 | 0.00 | 0.36 |
| September | 0.514843E+09 | 4408621.18 | 0.00 | 570856.29 | 0.00 | 0.195519E+09 | 88235363.97 | 0.00 | 0.35 |
| October | 0.250855E+09 | 0.00 | 0.00 | 27125.02 | 0.00 | 0.103621E+10 | 7905151.61 | 0.00 | 0.35 |
| November | 12955716.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179276E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288237E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.239945E+10 | 0.591090E+09 | 0.00 | 6384358.35 | 76797.45 | 0.146155E+11 | 0.775458E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.514843E+09 | 0.268956E+09 | 0.00 | 1618502.41 | 58440.28 | 0.306580E+10 | 0.176729E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 75710909.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298976E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.179687E+09 | 0.00 | 0.00 | 4138.41 | 0.00 | 0.219888E+10 | 5287240.73 | 0.00 | 0.35 |
| March | 0.323595E+09 | 0.00 | 0.00 | 120573.33 | 0.00 | 0.184724E+10 | 51620883.30 | 0.00 | 0.35 |
| April | 0.446144E+09 | 1747775.45 | 0.00 | 732590.90 | 0.00 | 0.826485E+09 | 0.130464E+09 | 0.00 | 0.35 |
| May | 0.465388E+09 | 30041033.07 | 0.00 | 1792804.41 | 0.00 | 0.101045E+09 | 0.237494E+09 | 0.00 | 0.35 |
| June | 0.254621E+09 | 0.181306E+09 | 0.00 | 2048046.60 | 0.00 | 0.00 | 0.197247E+09 | 0.00 | 0.36 |
| July | 0.158482E+09 | 0.286401E+09 | 0.00 | 1806360.19 | 0.00 | 0.00 | 0.157121E+09 | 0.00 | 0.36 |
| August | 0.248021E+09 | 0.127931E+09 | 0.00 | 1766846.29 | 0.00 | 3717148.30 | 0.181858E+09 | 0.00 | 0.36 |
| September | 0.494231E+09 | 6534047.69 | 0.00 | 1613597.76 | 0.00 | 0.146698E+09 | 0.181873E+09 | 0.00 | 0.35 |
| October | 0.367512E+09 | 0.00 | 0.00 | 601168.40 | 0.00 | 0.865674E+09 | 87710479.09 | 0.00 | 0.35 |
| November | 0.147323E+09 | 0.00 | 0.00 | 2411.65 | 0.00 | 0.165929E+10 | 2638229.56 | 0.00 | 0.35 |
| December | 47240805.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.283495E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.320796E+10 | 0.633961E+09 | 0.00 | 10488537.94 | 0.00 | 0.134737E+11 | 0.123331E+10 | 0.00 | 0.35 |
| Minimum of Months | 47240805.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.494231E+09 | 0.286401E+09 | 0.00 | 2048046.60 | 0.00 | 0.298976E+10 | 0.237494E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306576E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237898E+10 | 0.00 | 0.00 | 0.35 |
| March | 96170327.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210914E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.368734E+09 | 1503636.76 | 0.00 | 36722.43 | 0.00 | 0.988380E+09 | 15107022.90 | 0.00 | 0.35 |
| May | 0.497620E+09 | 27976229.41 | 0.00 | 1131671.36 | 0.00 | 0.121376E+09 | 0.174781E+09 | 0.00 | 0.35 |
| June | 0.250513E+09 | 0.178026E+09 | 0.00 | 1863392.42 | 0.00 | 0.00 | 0.200994E+09 | 0.00 | 0.36 |
| July | 0.157548E+09 | 0.273008E+09 | 0.00 | 1704490.21 | 0.00 | 0.00 | 0.160176E+09 | 0.00 | 0.36 |
| August | 0.270284E+09 | 0.113679E+09 | 0.00 | 1293280.10 | 0.00 | 5439184.54 | 0.166109E+09 | 0.00 | 0.36 |
| September | 0.522272E+09 | 4823722.47 | 0.00 | 415073.55 | 0.00 | 0.191932E+09 | 91044034.40 | 0.00 | 0.35 |
| October | 0.249275E+09 | 0.00 | 0.00 | 878.03 | 0.00 | 0.104325E+10 | 652102.74 | 0.00 | 0.35 |
| November | 9512429.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179610E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288231E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.242193E+10 | 0.599018E+09 | 0.00 | 6445508.10 | 0.00 | 0.145827E+11 | 0.808863E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.522272E+09 | 0.273008E+09 | 0.00 | 1863392.42 | 0.00 | 0.306576E+10 | 0.200994E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307314E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238568E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.124455E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208777E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.426695E+09 | 1471899.74 | 0.00 | 13595.79 | 7363.96 | 0.942066E+09 | 5246008.48 | 0.00 | 0.35 |
| May | 0.540924E+09 | 26582124.00 | 0.00 | 946362.20 | 0.00 | 64882067.81 | 0.198669E+09 | 0.00 | 0.35 |
| June | 0.256732E+09 | 0.171425E+09 | 0.00 | 1387304.28 | 0.00 | 0.00 | 0.204632E+09 | 0.00 | 0.36 |
| July | 0.131932E+09 | 0.257212E+09 | 0.00 | 1353454.58 | 0.00 | 0.00 | 0.192232E+09 | 0.00 | 0.36 |
| August | 0.238907E+09 | 0.105481E+09 | 0.00 | 1176088.21 | 18325.83 | 0.00 | 0.212618E+09 | 0.00 | 0.36 |
| September | 0.676653E+09 | 4056499.77 | 0.00 | 310979.15 | 0.00 | 59096851.21 | 84209497.73 | 0.00 | 0.35 |
| October | 0.459568E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.841031E+09 | 0.00 | 0.00 | 0.35 |
| November | 30493649.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178326E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289036E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.288636E+10 | 0.566229E+09 | 0.00 | 5187784.21 | 25689.79 | 0.141273E+11 | 0.897606E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.676653E+09 | 0.257212E+09 | 0.00 | 1387304.28 | 18325.83 | 0.307314E+10 | 0.212618E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307314E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238568E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.124212E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208795E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.427473E+09 | 1469599.56 | 0.00 | 13879.39 | 5843.92 | 0.941035E+09 | 5752141.32 | 0.00 | 0.35 |
| May | 0.541864E+09 | 26606795.49 | 0.00 | 943031.10 | 0.00 | 65017336.66 | 0.198076E+09 | 0.00 | 0.35 |
| June | 0.255716E+09 | 0.171493E+09 | 0.00 | 1401812.14 | 0.00 | 0.00 | 0.205932E+09 | 0.00 | 0.36 |
| July | 0.132354E+09 | 0.257420E+09 | 0.00 | 1359455.82 | 0.00 | 0.00 | 0.191920E+09 | 0.00 | 0.36 |
| August | 0.240152E+09 | 0.105689E+09 | 0.00 | 1175355.92 | 15037.98 | 0.00 | 0.211750E+09 | 0.00 | 0.36 |
| September | 0.675244E+09 | 4088052.71 | 0.00 | 313061.00 | 0.00 | 59950924.41 | 85412351.80 | 0.00 | 0.35 |
| October | 0.459289E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.841246E+09 | 0.00 | 0.00 | 0.35 |
| November | 30326319.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178343E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289036E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.288663E+10 | 0.566767E+09 | 0.00 | 5206595.36 | 20881.91 | 0.141278E+11 | 0.898842E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.675244E+09 | 0.257420E+09 | 0.00 | 1401812.14 | 15037.98 | 0.307314E+10 | 0.211750E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.205089E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.286807E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.360513E+09 | 0.00 | 0.00 | 27765.45 | 0.00 | 0.201227E+10 | 21607223.46 | 0.00 | 0.35 |
| March | 0.501112E+09 | 0.00 | 0.00 | 194605.57 | 0.00 | 0.166864E+10 | 62807684.74 | 0.00 | 0.35 |
| April | 0.617094E+09 | 1778630.67 | 0.00 | 636036.10 | 0.00 | 0.667903E+09 | 0.130688E+09 | 0.00 | 0.35 |
| May | 0.505478E+09 | 29159457.54 | 0.00 | 1592841.83 | 0.00 | 42274458.83 | 0.273100E+09 | 0.00 | 0.35 |
| June | 0.258662E+09 | 0.175948E+09 | 0.00 | 1604229.21 | 0.00 | 0.00 | 0.202294E+09 | 0.00 | 0.36 |
| July | 0.135861E+09 | 0.274894E+09 | 0.00 | 1497234.21 | 16775.31 | 0.00 | 0.184402E+09 | 0.00 | 0.36 |
| August | 0.201205E+09 | 0.123654E+09 | 0.00 | 1682308.16 | 1539.40 | 0.00 | 0.239704E+09 | 0.00 | 0.36 |
| September | 0.587724E+09 | 6199574.54 | 0.00 | 1552468.94 | 0.00 | 33286596.27 | 0.225433E+09 | 0.00 | 0.35 |
| October | 0.576236E+09 | 0.00 | 0.00 | 632802.61 | 0.00 | 0.661247E+09 | 0.100509E+09 | 0.00 | 0.35 |
| November | 0.291094E+09 | 0.00 | 0.00 | 11701.70 | 0.00 | 0.152326E+10 | 5860887.88 | 0.00 | 0.35 |
| December | 0.120743E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276953E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.436081E+10 | 0.611634E+09 | 0.00 | 9431993.79 | 18314.71 | 0.122465E+11 | 0.144641E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.120743E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.617094E+09 | 0.274894E+09 | 0.00 | 1682308.16 | 16775.31 | 0.286807E+10 | 0.273100E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.205048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.286811E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.358666E+09 | 0.00 | 0.00 | 28146.99 | 0.00 | 0.201388E+10 | 21772720.70 | 0.00 | 0.35 |
| March | 0.499397E+09 | 0.00 | 0.00 | 196381.79 | 0.00 | 0.166986E+10 | 63272362.47 | 0.00 | 0.35 |
| April | 0.618522E+09 | 1776291.99 | 0.00 | 647268.18 | 0.00 | 0.667091E+09 | 0.130358E+09 | 0.00 | 0.35 |
| May | 0.504561E+09 | 29175484.95 | 0.00 | 1596027.58 | 0.00 | 42178837.90 | 0.274209E+09 | 0.00 | 0.35 |
| June | 0.258265E+09 | 0.176009E+09 | 0.00 | 1616338.71 | 0.00 | 0.00 | 0.202940E+09 | 0.00 | 0.36 |
| July | 0.137287E+09 | 0.275063E+09 | 0.00 | 1497978.46 | 6410.85 | 0.00 | 0.183164E+09 | 0.00 | 0.36 |
| August | 0.201131E+09 | 0.123767E+09 | 0.00 | 1680636.25 | 571.62 | 0.00 | 0.240093E+09 | 0.00 | 0.36 |
| September | 0.586649E+09 | 6213213.02 | 0.00 | 1556116.89 | 0.00 | 34880729.86 | 0.224904E+09 | 0.00 | 0.35 |
| October | 0.574480E+09 | 0.00 | 0.00 | 634855.67 | 0.00 | 0.662718E+09 | 0.100588E+09 | 0.00 | 0.35 |
| November | 0.290907E+09 | 0.00 | 0.00 | 12048.65 | 0.00 | 0.152322E+10 | 6118589.76 | 0.00 | 0.35 |
| December | 0.119705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.277056E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.435462E+10 | 0.612004E+09 | 0.00 | 9465799.16 | 6982.47 | 0.122525E+11 | 0.144742E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.119705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.618522E+09 | 0.275063E+09 | 0.00 | 1680636.25 | 6410.85 | 0.286811E+10 | 0.274209E+09 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:42
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.991491E+11 | 0.334397E+11 | 0.00 | 0.405613E+10 | 0.449029E+11 |
| February | 0.129238E+12 | 0.282171E+11 | 0.00 | 0.312140E+10 | 0.315240E+11 |
| March | 0.166951E+12 | 0.221486E+11 | 0.00 | 0.288341E+10 | 0.242977E+11 |
| April | 0.193326E+12 | 0.179629E+11 | 0.00 | 0.185212E+10 | 0.130515E+11 |
| May | 0.216047E+12 | 0.105025E+11 | 0.00 | 0.123060E+10 | 0.380698E+11 |
| June | 0.219636E+12 | 0.595365E+10 | 0.00 | 0.715864E+09 | 0.799749E+11 |
| July | 0.223123E+12 | 0.298267E+10 | 0.00 | 0.619506E+09 | 0.114099E+12 |
| August | 0.191830E+12 | 0.695862E+10 | 0.00 | 0.770877E+09 | 0.816210E+11 |
| September | 0.148325E+12 | 0.123773E+11 | 0.00 | 0.146482E+10 | 0.246754E+11 |
| October | 0.906923E+11 | 0.138872E+11 | 0.00 | 0.195910E+10 | 0.108051E+11 |
| November | 0.564735E+11 | 0.219174E+11 | 0.00 | 0.235350E+10 | 0.202777E+11 |
| December | 0.726774E+11 | 0.331039E+11 | 0.00 | 0.379433E+10 | 0.426168E+11 |
| Annual Sum or Average | 0.180747E+13 | 0.209451E+12 | 0.00 | 0.248217E+11 | 0.525916E+12 |
| Minimum of Months | 0.564735E+11 | 0.298267E+10 | 0.00 | 0.619506E+09 | 0.108051E+11 |
| Maximum of Months | 0.223123E+12 | 0.334397E+11 | 0.00 | 0.405613E+10 | 0.114099E+12 |