Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190
Simulation Timestamp: 2023-10-16 09:14:20
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1537.31 | 490.43 | 544.38 |
| Net Site Energy | 1537.31 | 490.43 | 544.38 |
| Total Source Energy | 4382.29 | 1398.03 | 1551.82 |
| Net Source Energy | 4382.29 | 1398.03 | 1551.82 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 233.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 169.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 106.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 419.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1303.81 | 233.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 233.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 169.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 50.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 106.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 419.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 233.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 169.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 50.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 106.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 419.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 246.42 | 82.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 461.69 | 82.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 222.00 | 74.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 415.94 | 74.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1303.814 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1303.814 | 100.00 |
| Total On-Site and Utility Electric Sources | 1303.814 | 100.00 |
| Total Electricity End Uses | 1303.814 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 49.52 |
| Air to Air Heat Recovery for Heating | 0.00 | 50.48 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8342.67 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:14 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
| Latitude [deg] | 33.63 |
| Longitude [deg] | -84.4 |
| Elevation [m] | 308.00 |
| Time Zone | -5.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 29-AUG-17:10 | 12-FEB-05:00 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 124189.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 25094.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 5231.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22609.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 8194.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 36271.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 97401.70 | 124189.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 124189.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 25094.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4887.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 344.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18441.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 8194.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 36271.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 538.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 336.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1329.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 4129.18 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 89.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 190.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 56.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 119.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 470.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1462.19 | 89.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 80.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 171.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 107.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 424.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1317.28 | 80.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.347590 |
| SPLIT GNW SUPPLY FAN | 0.339054 |
| SPLIT OFFICE SUPPLY FAN | 0.369475 |
| SPLIT GNE SUPPLY FAN | 0.313626 |
| SPLIT GN1 SUPPLY FAN | 0.283947 |
| SPLIT GN2 SUPPLY FAN | 0.283517 |
| SPLIT GS1 SUPPLY FAN | 0.295495 |
| SPLIT GS2 SUPPLY FAN | 0.297947 |
| SPLIT MSW SUPPLY FAN | 0.844021 |
| SPLIT MNW SUPPLY FAN | 0.828427 |
| SPLIT MSE SUPPLY FAN | 0.774290 |
| SPLIT MNE SUPPLY FAN | 0.758930 |
| SPLIT MN1 SUPPLY FAN | 0.679309 |
| SPLIT MN2 SUPPLY FAN | 0.678320 |
| SPLIT MS1 SUPPLY FAN | 0.697336 |
| SPLIT MS2 SUPPLY FAN | 0.696315 |
| SPLIT TSW SUPPLY FAN | 0.478493 |
| SPLIT TNW SUPPLY FAN | 0.474007 |
| SPLIT TSE SUPPLY FAN | 0.426157 |
| SPLIT TNE SUPPLY FAN | 0.421635 |
| SPLIT TN1 SUPPLY FAN | 0.388439 |
| SPLIT TN2 SUPPLY FAN | 0.386963 |
| SPLIT TS1 SUPPLY FAN | 0.393652 |
| SPLIT TS2 SUPPLY FAN | 0.392183 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.347590 |
| G NW APARTMENT DIRECT AIR | 0.339054 |
| OFFICE DIRECT AIR | 0.369475 |
| G NE APARTMENT DIRECT AIR | 0.313626 |
| G N1 APARTMENT DIRECT AIR | 0.283947 |
| G N2 APARTMENT DIRECT AIR | 0.283517 |
| G S1 APARTMENT DIRECT AIR | 0.295495 |
| G S2 APARTMENT DIRECT AIR | 0.297947 |
| M SW APARTMENT DIRECT AIR | 0.844021 |
| M NW APARTMENT DIRECT AIR | 0.828427 |
| M SE APARTMENT DIRECT AIR | 0.774290 |
| M NE APARTMENT DIRECT AIR | 0.758930 |
| M N1 APARTMENT DIRECT AIR | 0.679309 |
| M N2 APARTMENT DIRECT AIR | 0.678320 |
| M S1 APARTMENT DIRECT AIR | 0.697336 |
| M S2 APARTMENT DIRECT AIR | 0.696315 |
| T SW APARTMENT DIRECT AIR | 0.478493 |
| T NW APARTMENT DIRECT AIR | 0.474007 |
| T SE APARTMENT DIRECT AIR | 0.426157 |
| T NE APARTMENT DIRECT AIR | 0.421635 |
| T N1 APARTMENT DIRECT AIR | 0.388439 |
| T N2 APARTMENT DIRECT AIR | 0.386963 |
| T S1 APARTMENT DIRECT AIR | 0.393652 |
| T S2 APARTMENT DIRECT AIR | 0.392183 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.347590 | 0.347590 | 0.347590 | 0.347590 | 0.347590 | 0.347590 | 1.00 | 1.00 | 0.347590 |
| SPLIT GNW | 0.339054 | 0.339054 | 0.339054 | 0.339054 | 0.339054 | 0.339054 | 1.00 | 1.00 | 0.339054 |
| SPLIT OFFICE | 0.369475 | 0.369475 | 0.369475 | 0.369475 | 0.369475 | 0.369475 | 1.00 | 1.000000 | 0.369475 |
| SPLIT GNE | 0.313626 | 0.313626 | 0.313626 | 0.313626 | 0.313626 | 0.313626 | 1.00 | 1.000000 | 0.313626 |
| SPLIT GN1 | 0.283947 | 0.283947 | 0.283947 | 0.283947 | 0.283947 | 0.283947 | 1.00 | 1.00 | 0.283947 |
| SPLIT GN2 | 0.283517 | 0.283517 | 0.283517 | 0.283517 | 0.283517 | 0.283517 | 1.00 | 1.00 | 0.283517 |
| SPLIT GS1 | 0.295495 | 0.295495 | 0.295495 | 0.295495 | 0.295495 | 0.295495 | 1.00 | 1.00 | 0.295495 |
| SPLIT GS2 | 0.297947 | 0.297947 | 0.297947 | 0.297947 | 0.297947 | 0.297947 | 1.00 | 1.00 | 0.297947 |
| SPLIT MSW | 0.844021 | 0.844021 | 0.844021 | 0.844021 | 0.844021 | 0.844021 | 1.00 | 1.00 | 0.844021 |
| SPLIT MNW | 0.828427 | 0.828427 | 0.828427 | 0.828427 | 0.828427 | 0.828427 | 1.00 | 1.00 | 0.828427 |
| SPLIT MSE | 0.774290 | 0.774290 | 0.774290 | 0.774290 | 0.774290 | 0.774290 | 1.00 | 1.00 | 0.774290 |
| SPLIT MNE | 0.758930 | 0.758930 | 0.758930 | 0.758930 | 0.758930 | 0.758930 | 1.00 | 1.00 | 0.758930 |
| SPLIT MN1 | 0.679309 | 0.679309 | 0.679309 | 0.679309 | 0.679309 | 0.679309 | 1.00 | 1.000000 | 0.679309 |
| SPLIT MN2 | 0.678320 | 0.678320 | 0.678320 | 0.678320 | 0.678320 | 0.678320 | 1.00 | 1.00 | 0.678320 |
| SPLIT MS1 | 0.697336 | 0.697336 | 0.697336 | 0.697336 | 0.697336 | 0.697336 | 1.00 | 1.000000 | 0.697336 |
| SPLIT MS2 | 0.696315 | 0.696315 | 0.696315 | 0.696315 | 0.696315 | 0.696315 | 1.00 | 1.00 | 0.696315 |
| SPLIT TSW | 0.478493 | 0.478493 | 0.478493 | 0.478493 | 0.478493 | 0.478493 | 1.00 | 1.00 | 0.478493 |
| SPLIT TNW | 0.474007 | 0.474007 | 0.474007 | 0.474007 | 0.474007 | 0.474007 | 1.00 | 1.00 | 0.474007 |
| SPLIT TSE | 0.426157 | 0.426157 | 0.426157 | 0.426157 | 0.426157 | 0.426157 | 1.00 | 1.00 | 0.426157 |
| SPLIT TNE | 0.421635 | 0.421635 | 0.421635 | 0.421635 | 0.421635 | 0.421635 | 1.00 | 1.00 | 0.421635 |
| SPLIT TN1 | 0.388439 | 0.388439 | 0.388439 | 0.388439 | 0.388439 | 0.388439 | 1.00 | 1.000000 | 0.388439 |
| SPLIT TN2 | 0.386963 | 0.386963 | 0.386963 | 0.386963 | 0.386963 | 0.386963 | 1.00 | 1.000000 | 0.386963 |
| SPLIT TS1 | 0.393652 | 0.393652 | 0.393652 | 0.393652 | 0.393652 | 0.393652 | 1.00 | 1.00 | 0.393652 |
| SPLIT TS2 | 0.392183 | 0.392183 | 0.392183 | 0.392183 | 0.392183 | 0.392183 | 1.00 | 1.00 | 0.392183 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.347590 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.339054 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.369475 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.313626 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.283947 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.283517 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.295495 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.297947 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.844021 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.828427 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.774290 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.758930 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.679309 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.678320 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.697336 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.696315 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.478493 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.474007 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.426157 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.421635 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.388439 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.386963 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.393652 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.392183 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.347590 | 0.347590 | 0.347590 | 0.347590 | 6135.75 | 8494.11 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.339054 | 0.339054 | 0.339054 | 0.339054 | 5991.40 | 8305.79 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.369475 | 0.369475 | 0.369475 | 0.369475 | 6497.81 | 9365.09 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.313626 | 0.313626 | 0.313626 | 0.313626 | 5621.58 | 7745.09 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.283947 | 0.283947 | 0.283947 | 0.283947 | 5092.00 | 7090.56 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.283517 | 0.283517 | 0.283517 | 0.283517 | 5085.59 | 7081.07 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.295495 | 0.295495 | 0.295495 | 0.295495 | 5292.73 | 7345.26 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.297947 | 0.297947 | 0.297947 | 0.297947 | 5329.58 | 7399.32 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.844021 | 0.844021 | 0.844021 | 0.844021 | 14667.29 | 20271.86 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.828427 | 0.828427 | 0.828427 | 0.828427 | 14409.67 | 19927.72 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.774290 | 0.774290 | 0.774290 | 0.774290 | 13643.81 | 18734.12 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.758930 | 0.758930 | 0.758930 | 0.758930 | 13388.11 | 18395.16 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.679309 | 0.679309 | 0.679309 | 0.679309 | 11966.85 | 16638.56 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.678320 | 0.678320 | 0.678320 | 0.678320 | 11952.30 | 16616.76 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.697336 | 0.697336 | 0.697336 | 0.697336 | 12268.44 | 17036.29 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.696315 | 0.696315 | 0.696315 | 0.696315 | 12253.54 | 17013.78 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.478493 | 0.478493 | 0.478493 | 0.478493 | 8282.61 | 11382.07 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.474007 | 0.474007 | 0.474007 | 0.474007 | 8203.90 | 11283.00 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.426157 | 0.426157 | 0.426157 | 0.426157 | 7500.88 | 10227.87 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.421635 | 0.421635 | 0.421635 | 0.421635 | 7420.69 | 10128.00 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.388439 | 0.388439 | 0.388439 | 0.388439 | 6757.00 | 9395.32 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.386963 | 0.386963 | 0.386963 | 0.386963 | 6735.06 | 9362.76 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.393652 | 0.393652 | 0.393652 | 0.393652 | 6848.70 | 9510.40 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.392183 | 0.392183 | 0.392183 | 0.392183 | 6826.92 | 9478.02 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.347590 | 6135.75 | 0.800772 |
| SPLIT GNW COOLING COIL | 0.339054 | 5991.40 | 0.800407 |
| SPLIT OFFICE COOLING COIL | 0.369475 | 6497.81 | 0.800058 |
| SPLIT GNE COOLING COIL | 0.313626 | 5621.58 | 0.800536 |
| SPLIT GN1 COOLING COIL | 0.283947 | 5092.00 | 0.800375 |
| SPLIT GN2 COOLING COIL | 0.283517 | 5085.59 | 0.800288 |
| SPLIT GS1 COOLING COIL | 0.295495 | 5292.73 | 0.800784 |
| SPLIT GS2 COOLING COIL | 0.297947 | 5329.58 | 0.800234 |
| SPLIT MSW COOLING COIL | 0.844021 | 14667.29 | 0.800216 |
| SPLIT MNW COOLING COIL | 0.828427 | 14409.67 | 0.800890 |
| SPLIT MSE COOLING COIL | 0.774290 | 13643.81 | 0.800382 |
| SPLIT MNE COOLING COIL | 0.758930 | 13388.11 | 0.800996 |
| SPLIT MN1 COOLING COIL | 0.679309 | 11966.85 | 0.800477 |
| SPLIT MN2 COOLING COIL | 0.678320 | 11952.30 | 0.800394 |
| SPLIT MS1 COOLING COIL | 0.697336 | 12268.44 | 0.800927 |
| SPLIT MS2 COOLING COIL | 0.696315 | 12253.54 | 0.800841 |
| SPLIT TSW COOLING COIL | 0.478493 | 8282.61 | 0.800593 |
| SPLIT TNW COOLING COIL | 0.474007 | 8203.90 | 0.800639 |
| SPLIT TSE COOLING COIL | 0.426157 | 7500.88 | 0.800771 |
| SPLIT TNE COOLING COIL | 0.421635 | 7420.69 | 0.800799 |
| SPLIT TN1 COOLING COIL | 0.388439 | 6757.00 | 0.800865 |
| SPLIT TN2 COOLING COIL | 0.386963 | 6735.06 | 0.800671 |
| SPLIT TS1 COOLING COIL | 0.393652 | 6848.70 | 0.800813 |
| SPLIT TS2 COOLING COIL | 0.392183 | 6826.92 | 0.800620 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 8494.11 |
| SPLIT GNW HEATING COIL | 8305.79 |
| SPLIT OFFICE HEATING COIL | 9365.09 |
| SPLIT GNE HEATING COIL | 7745.09 |
| SPLIT GN1 HEATING COIL | 7090.56 |
| SPLIT GN2 HEATING COIL | 7081.07 |
| SPLIT GS1 HEATING COIL | 7345.26 |
| SPLIT GS2 HEATING COIL | 7399.32 |
| SPLIT MSW HEATING COIL | 20271.86 |
| SPLIT MNW HEATING COIL | 19927.72 |
| SPLIT MSE HEATING COIL | 18734.12 |
| SPLIT MNE HEATING COIL | 18395.16 |
| SPLIT MN1 HEATING COIL | 16638.56 |
| SPLIT MN2 HEATING COIL | 16616.76 |
| SPLIT MS1 HEATING COIL | 17036.29 |
| SPLIT MS2 HEATING COIL | 17013.78 |
| SPLIT TSW HEATING COIL | 11382.07 |
| SPLIT TNW HEATING COIL | 11283.00 |
| SPLIT TSE HEATING COIL | 10227.87 |
| SPLIT TNE HEATING COIL | 10128.00 |
| SPLIT TN1 HEATING COIL | 9395.32 |
| SPLIT TN2 HEATING COIL | 9362.76 |
| SPLIT TS1 HEATING COIL | 9510.40 |
| SPLIT TS2 HEATING COIL | 9478.02 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 11.90 | 7.70 | 4.00 | 7.90 | 13.80 | 17.20 | 20.80 | 24.80 | 26.10 | 26.50 | 22.50 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 | 33.63 | -84.43 | -5.00 | 308.00 | 97679 | 1.1610 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 16.60 | 22.50 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.192E-004 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 3955.24052 | 4746.28862 | 0.28966 | 0.34759 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 2069.16826 | 2483.00192 | 9.24714E-002 | 0.11097 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3860.32617 | 4632.39140 | 0.28254 | 0.33905 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 1960.88141 | 2353.05769 | 8.76331E-002 | 0.10516 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4045.51160 | 4854.61392 | 0.30790 | 0.36947 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 29.71333 | 1.44647E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 2504.23603 | 3005.08323 | 0.11191 | 0.13430 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | -6.30000 | 2.29779E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 3576.39337 | 4291.67204 | 0.26135 | 0.31363 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 1953.99336 | 2344.79204 | 8.73253E-002 | 0.10479 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 3246.78821 | 3896.14585 | 0.23662 | 0.28395 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 1165.21830 | 1398.26196 | 5.20754E-002 | 6.24905E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 3242.03850 | 3890.44620 | 0.23626 | 0.28352 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 1165.01287 | 1398.01545 | 5.20663E-002 | 6.24795E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3374.90068 | 4049.88082 | 0.24625 | 0.29549 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 1275.11626 | 1530.13951 | 5.69863E-002 | 6.83836E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3402.06797 | 4082.48156 | 0.24829 | 0.29795 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 1283.24719 | 1539.89663 | 5.73497E-002 | 6.88197E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 9562.11140 | 11474.53367 | 0.70335 | 0.84402 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 4146.92881 | 4976.31458 | 0.18531 | 0.22237 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 9388.25873 | 11265.91047 | 0.69036 | 0.82843 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 3885.55943 | 4662.67132 | 0.17363 | 0.20836 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 8786.75095 | 10544.10114 | 0.64524 | 0.77429 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 4130.31997 | 4956.38397 | 0.18457 | 0.22148 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 8616.15705 | 10339.38847 | 0.63244 | 0.75893 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 3868.88886 | 4642.66663 | 0.17289 | 0.20746 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 7735.09241 | 9282.11089 | 0.56609 | 0.67931 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 2083.85885 | 2500.63062 | 9.31258E-002 | 0.11175 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 7724.17441 | 9269.00929 | 0.56527 | 0.67832 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 2083.41966 | 2500.10359 | 9.31062E-002 | 0.11173 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 7934.27306 | 9521.12767 | 0.58111 | 0.69734 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 2338.71717 | 2806.46060 | 0.10451 | 0.12542 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 7922.98583 | 9507.58300 | 0.58026 | 0.69632 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 2338.28354 | 2805.94025 | 0.10449 | 0.12539 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5412.59401 | 6495.11281 | 0.39874 | 0.47849 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 3441.64737 | 4129.97684 | 0.15378 | 0.18454 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 5362.74699 | 6435.29639 | 0.39501 | 0.47401 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 3305.41313 | 3966.49576 | 0.14770 | 0.17724 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4830.52765 | 5796.63318 | 0.35513 | 0.42616 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 3430.90208 | 4117.08250 | 0.15330 | 0.18397 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 4779.67311 | 5735.60773 | 0.35136 | 0.42163 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 3294.58946 | 3953.50735 | 0.14722 | 0.17666 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 4410.02260 | 5292.02712 | 0.32370 | 0.38844 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 2218.44105 | 2662.12926 | 9.91365E-002 | 0.11896 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 4393.59672 | 5272.31607 | 0.32247 | 0.38696 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 2218.13711 | 2661.76453 | 9.91229E-002 | 0.11895 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4468.34673 | 5362.01608 | 0.32804 | 0.39365 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 2355.02820 | 2826.03384 | 0.10524 | 0.12629 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4452.00117 | 5342.40141 | 0.32682 | 0.39218 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.69500 | 1.44665E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 2354.72861 | 2825.67433 | 0.10523 | 0.12627 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -6.30000 | 2.29779E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4759.59 | 0.34759 | 0.34759 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 3276.45 | 0.11097 | 0.11097 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4646.85 | 0.33905 | 0.33905 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 3148.40 | 0.10516 | 0.10516 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5042.40 | 0.36947 | 0.36947 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 4179.33 | 0.13430 | 0.13430 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 4310.68 | 0.31363 | 0.31363 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 3140.26 | 0.10479 | 0.10479 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3918.18 | 0.28395 | 0.28395 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 2207.53 | 6.24905E-002 | 6.24905E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3912.49 | 0.28352 | 0.28352 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 2207.28 | 6.24795E-002 | 6.24795E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 4071.46 | 0.29549 | 0.29549 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 2337.48 | 6.83836E-002 | 6.83836E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 4103.72 | 0.29795 | 0.29795 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 2347.09 | 6.88197E-002 | 6.88197E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 11481.44 | 0.84402 | 0.84402 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 6562.94 | 0.22237 | 0.22237 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 11275.50 | 0.82843 | 0.82843 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 6253.89 | 0.20836 | 0.20836 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 10561.68 | 0.77429 | 0.77429 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 6543.30 | 0.22148 | 0.22148 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 10359.03 | 0.75893 | 0.75893 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 6234.17 | 0.20746 | 0.20746 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 9310.48 | 0.67931 | 0.67931 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 4123.40 | 0.11175 | 0.11175 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 9297.47 | 0.67832 | 0.67832 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 4122.88 | 0.11173 | 0.11173 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9548.07 | 0.69734 | 0.69734 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 4424.76 | 0.12542 | 0.12542 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9534.63 | 0.69632 | 0.69632 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 4424.25 | 0.12539 | 0.12539 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6487.42 | 0.47849 | 0.47849 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 4899.34 | 0.18454 | 0.18454 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 6428.34 | 0.47401 | 0.47401 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 4738.25 | 0.17724 | 0.17724 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 5797.66 | 0.42616 | 0.42616 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 4886.64 | 0.18397 | 0.18397 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 5737.74 | 0.42163 | 0.42163 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 4725.45 | 0.17666 | 0.17666 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 5300.02 | 0.38844 | 0.38844 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 3452.93 | 0.11896 | 0.11896 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 5280.55 | 0.38696 | 0.38696 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 3452.57 | 0.11895 | 0.11895 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5368.97 | 0.39365 | 0.39365 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 3614.44 | 0.12629 | 0.12629 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5349.61 | 0.39218 | 0.39218 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 3614.08 | 0.12627 | 0.12627 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34759 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33905 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36947 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31363 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.28395 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.28352 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29549 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29795 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.84402 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.82843 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.77429 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.75893 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.67931 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.67832 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.69734 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.69632 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.47849 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.47401 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42616 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42163 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38844 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38696 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.39365 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.39218 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34759 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34759 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34759 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34759 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34759 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.34759 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33905 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33905 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33905 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33905 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33905 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.33905 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36947 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36947 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36947 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36947 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36947 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.36947 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31363 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31363 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31363 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31363 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31363 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.31363 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.28395 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.28395 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.28395 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.28395 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.28395 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.28395 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.28352 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.28352 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.28352 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.28352 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.28352 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.28352 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29549 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29549 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29549 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29549 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29549 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29549 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29795 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29795 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29795 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29795 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29795 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29795 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.84402 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.84402 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.84402 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.84402 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.84402 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.84402 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.82843 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.82843 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.82843 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.82843 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.82843 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.82843 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.77429 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.77429 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.77429 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.77429 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.77429 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.77429 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.75893 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.75893 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.75893 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.75893 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.75893 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.75893 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.67931 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.67931 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.67931 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.67931 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.67931 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.67931 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.67832 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.67832 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.67832 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.67832 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.67832 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.67832 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.69734 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.69734 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.69734 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.69734 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.69734 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.69734 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.69632 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.69632 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.69632 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.69632 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.69632 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.69632 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.47849 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.47849 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.47849 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.47849 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.47849 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.47849 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.47401 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.47401 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.47401 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.47401 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.47401 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.47401 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42616 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42616 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42616 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42616 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42616 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.42616 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42163 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42163 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42163 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42163 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42163 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.42163 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38844 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38844 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38844 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38844 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38844 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.38844 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38696 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38696 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38696 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38696 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38696 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.38696 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.39365 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.39365 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.39365 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.39365 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.39365 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.39365 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.39218 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.39218 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.39218 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.39218 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.39218 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.39218 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.34759 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.33905 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.36947 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.31363 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.28395 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.28352 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.29549 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.29795 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.84402 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.82843 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.77429 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.75893 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.67931 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.67832 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.69734 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.69632 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.47849 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.47401 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.42616 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.42163 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.38844 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.38696 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.39365 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.39218 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34759 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34759 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34759 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34759 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34759 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6135.75194 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8494.11226 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34759 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34759 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6135.75194 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80077 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 8494.11226 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33905 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33905 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33905 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33905 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33905 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5991.40418 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8305.79300 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33905 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33905 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5991.40418 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80041 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 8305.79300 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36947 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36947 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36947 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36947 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36947 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6497.81306 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9365.08655 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36947 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36947 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6497.81306 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80006 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 9365.08655 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31363 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31363 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31363 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31363 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31363 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5621.57535 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7745.09397 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31363 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31363 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5621.57535 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80054 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 7745.09397 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.28395 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.28395 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28395 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28395 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28395 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5092.00111 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7090.55683 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.28395 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28395 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5092.00111 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80038 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 7090.55683 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.28352 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.28352 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28352 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28352 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28352 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5085.59260 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7081.07214 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.28352 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28352 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5085.59260 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80029 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 7081.07214 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29549 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29549 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29549 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29549 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29549 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5292.72792 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7345.25800 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29549 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29549 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5292.72792 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80078 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 7345.25800 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29795 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29795 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29795 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29795 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29795 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5329.57960 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7399.31730 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29795 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29795 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5329.57960 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80023 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 7399.31730 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.84402 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.84402 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.84402 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.84402 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.84402 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14667.28557 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20271.86150 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.84402 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.84402 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14667.28557 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80022 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 20271.86150 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.82843 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.82843 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.82843 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.82843 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.82843 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14409.66834 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 19927.71704 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.82843 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.82843 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14409.66834 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80089 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 19927.71704 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.77429 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.77429 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.77429 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.77429 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.77429 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13643.80539 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18734.12326 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.77429 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77429 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13643.80539 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80038 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 18734.12326 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.75893 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.75893 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.75893 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.75893 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.75893 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13388.11343 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18395.16373 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.75893 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.75893 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13388.11343 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80100 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 18395.16373 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.67931 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.67931 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.67931 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.67931 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67931 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11966.84592 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16638.55528 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.67931 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.67931 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11966.84592 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80048 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 16638.55528 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.67832 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.67832 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.67832 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.67832 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67832 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11952.30470 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16616.75591 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.67832 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.67832 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11952.30470 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80039 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 16616.75591 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.69734 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.69734 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.69734 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.69734 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.69734 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12268.44452 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17036.28984 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.69734 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69734 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12268.44452 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80093 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 17036.28984 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.69632 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.69632 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.69632 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.69632 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.69632 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12253.53869 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17013.78188 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.69632 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69632 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12253.53869 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80084 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 17013.78188 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.47849 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.47849 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.47849 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.47849 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.47849 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8282.60956 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11382.07047 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.47849 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.47849 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8282.60956 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80059 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 11382.07047 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.47401 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.47401 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.47401 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.47401 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.47401 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8203.89624 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11283.00123 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.47401 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.47401 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8203.89624 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80064 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 11283.00123 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42616 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42616 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42616 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42616 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42616 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7500.88495 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10227.86664 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42616 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42616 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7500.88495 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80077 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 10227.86664 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42163 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42163 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42163 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42163 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42163 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7420.69079 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10128.00309 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42163 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42163 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7420.69079 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80080 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 10128.00309 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38844 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38844 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38844 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38844 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38844 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6757.00470 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9395.32342 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38844 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38844 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6757.00470 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80087 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 9395.32342 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38696 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38696 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38696 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38696 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38696 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6735.05897 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9362.75966 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38696 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38696 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6735.05897 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80067 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 9362.75966 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.39365 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.39365 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.39365 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.39365 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.39365 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6848.70375 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9510.40249 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.39365 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39365 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6848.70375 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80081 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 9510.40249 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.39218 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.39218 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.39218 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.39218 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.39218 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6826.92004 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9478.01840 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.39218 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39218 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6826.92004 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80062 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 9478.01840 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 5863.1 | 3.17 | 10.81 | 11.24 | 10.63 | 10.57 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 5725.5 | 3.17 | 10.81 | 11.24 | 10.63 | 10.58 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 6208.0 | 3.16 | 10.80 | 11.23 | 10.62 | 10.56 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 5375.5 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 4869.2 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 4863.2 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 5060.9 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 5095.8 | 3.18 | 10.83 | 11.27 | 10.66 | 10.61 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 14005.4 | 3.16 | 10.77 | 11.20 | 10.59 | 10.53 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 13760.0 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 13036.5 | 3.17 | 10.80 | 11.23 | 10.62 | 10.57 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 12792.8 | 3.17 | 10.81 | 11.23 | 10.63 | 10.57 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 11434.0 | 3.17 | 10.80 | 11.23 | 10.62 | 10.57 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 11420.3 | 3.17 | 10.80 | 11.23 | 10.62 | 10.57 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 11721.5 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 11707.4 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 7907.4 | 3.16 | 10.77 | 11.19 | 10.59 | 10.51 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 7832.2 | 3.16 | 10.77 | 11.19 | 10.59 | 10.51 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 7166.6 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 7090.0 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 6452.4 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 6431.6 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 6540.0 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 6519.4 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4945_SHGC_0.25 | N/A | 2.811 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 8.1020627212E-003 | 2.3643121231E-002 | Pass | Pass | 0.4057378771 | 1.0320070166 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1018782577E-002 | 3.1962826569E-002 | Pass | Pass | 0.1589124620 | 0.3110588249 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 2.9822747657E-002 | 3.7177099251E-002 | Pass | Pass | 0.1147812024 | 0.3752858201 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0520766590E-002 | 3.0535455608E-002 | Pass | Pass | 0.1968311991 | 0.4813276718 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0547051831E-003 | 9.4798369983E-003 | Pass | Pass | 0.3077330264 | 0.5301187080 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0313897764E-003 | 9.4066430036E-003 | Pass | Pass | 0.3225671899 | 0.7045139112 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3646189321E-003 | 6.1471704114E-003 | Pass | Pass | 0.1624767985 | 0.3856127738 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.2274633745E-003 | 9.8836939617E-003 | Pass | Pass | 0.7244502769 | 3.8966069683 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7892698493E-003 | 7.2578183336E-003 | Pass | Pass | 1.1670829126 | 12.0927060641 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9900179620E-003 | 6.2932139436E-003 | Pass | Pass | 0.3444798688 | 1.4341321097 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.1376386598E-003 | 8.4056621647E-003 | Pass | Pass | 0.1707764901 | 0.3074611458 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.8907891590E-003 | 5.6994832739E-003 | Pass | Pass | 0.8462508257 | 5.7585321295 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 5.9978629552E-003 | 1.4689265862E-002 | Pass | Pass | 0.1019886397 | 0.5805375370 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.0226575304E-003 | 1.4735983780E-002 | Pass | Pass | 9.8018335121E-002 | 0.5335551784 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 8.4369137467E-003 | 1.8305843128E-002 | Pass | Pass | 3.9217480188E-002 | 7.9570108180E-002 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 8.4521733810E-003 | 1.8346551100E-002 | Pass | Pass | 3.8118828234E-002 | 7.8349006322E-002 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0348070112E-002 | 3.0591252589E-002 | Pass | Pass | 0.3127175101 | 1.5254763333 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.2846226402E-002 | 3.7544023541E-002 | Pass | Pass | 9.1061892048E-002 | 0.1836790735 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 9.6379716747E-003 | 2.8520430014E-002 | Pass | Pass | 0.2456703406 | 0.7197573253 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.2140183101E-002 | 3.5548979639E-002 | Pass | Pass | 0.1175450228 | 0.2750452947 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 5.4593498822E-003 | 1.6424874208E-002 | Pass | Pass | 0.8148874337 | 3.6575002900 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 5.4266554150E-003 | 1.6336588669E-002 | Pass | Pass | 0.7312416145 | 3.1235815362 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3154652028E-003 | 7.5063112401E-003 | Pass | Pass | 3.3517058036 | 34.9620191349 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.2653806627E-003 | 7.2958475643E-003 | Pass | Pass | 4.0962431481 | 42.2212998573 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 1.3590754226E-002 | 9.3142075527E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.1430236461 | 0.4279407620 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 5.5747338259E-003 | 7.2588611247E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1450.17 | 117.12 | 0.00 | 8.66 | 883.88 | 2459.84 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | -6.30 | 0.00 | -6.30 | Wetbulb [C] | 5.30 | 320.00 |
| ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.40 | 9.50 | 23.50 | Wetbulb [C] | 4.00 | 300.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 0.00 | 0 | |||
| Feb | 0.00 | 0 | |||
| Mar | 0.00 | 0 | |||
| Apr | 0.00 | 0 | |||
| May | 0.00 | 0 | |||
| Jun | 0.00 | 0 | |||
| Jul | 0.00 | 0 | |||
| Aug | 0.00 | 0 | |||
| Sep | 90.00 | 25 | |||
| Oct | 0.00 | 0 | |||
| Nov | 0.00 | 0 | |||
| Dec | 0.00 | 0 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.811 | 0.251 | 0.251 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.811 | 0.251 | 0.251 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.811 | 0.251 | 0.251 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.811 | 0.251 | 0.251 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.811 | 0.251 | 0.251 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.4945_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.811 | 0.251 | 0.251 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.4945_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.811 | 0.251 | 0.251 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.4945_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.811 | 0.251 | 0.251 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.4945_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.811 | 0.251 | 0.251 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.4945_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.811 | 0.251 | 0.251 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 2.811 | 0.251 | 0.251 | |||||||||||||||||
| North Total or Average | 112.97 | 2.811 | 0.251 | 0.251 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 2.811 | 0.251 | 0.251 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.77 | 83.77 | 50.06 | |
| Exterior Lighting Total | 3183.33 | 50.06 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6135.75 | 4913.34 | 1222.41 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5991.40 | 4795.56 | 1195.84 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6497.81 | 5198.63 | 1299.18 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5621.58 | 4500.27 | 1121.30 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5092.00 | 4075.51 | 1016.49 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5085.59 | 4069.94 | 1015.65 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5292.73 | 4238.33 | 1054.40 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5329.58 | 4264.91 | 1064.67 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14667.29 | 11736.99 | 2930.29 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14409.67 | 11540.57 | 2869.10 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13643.81 | 10920.26 | 2723.54 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13388.11 | 10723.83 | 2664.29 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11966.85 | 9579.19 | 2387.66 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11952.30 | 9566.56 | 2385.75 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12268.44 | 9826.13 | 2442.32 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12253.54 | 9813.13 | 2440.40 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8282.61 | 6631.00 | 1651.61 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8203.90 | 6568.36 | 1635.54 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7500.88 | 6006.49 | 1494.39 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7420.69 | 5942.48 | 1478.21 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6757.00 | 5411.45 | 1345.55 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6735.06 | 5392.57 | 1342.49 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6848.70 | 5484.53 | 1364.17 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6826.92 | 5465.77 | 1361.15 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 5863.1 | 3.17 | 10.81 | 11.24 | 10.63 | 10.57 | |
| SPLIT GNW COOLING COIL | 5725.5 | 3.17 | 10.81 | 11.24 | 10.63 | 10.58 | |
| SPLIT OFFICE COOLING COIL | 6208.0 | 3.16 | 10.80 | 11.23 | 10.62 | 10.56 | |
| SPLIT GNE COOLING COIL | 5375.5 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 | |
| SPLIT GN1 COOLING COIL | 4869.2 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 | |
| SPLIT GN2 COOLING COIL | 4863.2 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 | |
| SPLIT GS1 COOLING COIL | 5060.9 | 3.18 | 10.84 | 11.27 | 10.66 | 10.62 | |
| SPLIT GS2 COOLING COIL | 5095.8 | 3.18 | 10.83 | 11.27 | 10.66 | 10.61 | |
| SPLIT MSW COOLING COIL | 14005.4 | 3.16 | 10.77 | 11.20 | 10.59 | 10.53 | |
| SPLIT MNW COOLING COIL | 13760.0 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 | |
| SPLIT MSE COOLING COIL | 13036.5 | 3.17 | 10.80 | 11.23 | 10.62 | 10.57 | |
| SPLIT MNE COOLING COIL | 12792.8 | 3.17 | 10.81 | 11.23 | 10.63 | 10.57 | |
| SPLIT MN1 COOLING COIL | 11434.0 | 3.17 | 10.80 | 11.23 | 10.62 | 10.57 | |
| SPLIT MN2 COOLING COIL | 11420.3 | 3.17 | 10.80 | 11.23 | 10.62 | 10.57 | |
| SPLIT MS1 COOLING COIL | 11721.5 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 | |
| SPLIT MS2 COOLING COIL | 11707.4 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 | |
| SPLIT TSW COOLING COIL | 7907.4 | 3.16 | 10.77 | 11.19 | 10.59 | 10.51 | |
| SPLIT TNW COOLING COIL | 7832.2 | 3.16 | 10.77 | 11.19 | 10.59 | 10.51 | |
| SPLIT TSE COOLING COIL | 7166.6 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 | |
| SPLIT TNE COOLING COIL | 7090.0 | 3.17 | 10.80 | 11.23 | 10.62 | 10.56 | |
| SPLIT TN1 COOLING COIL | 6452.4 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 | |
| SPLIT TN2 COOLING COIL | 6431.6 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 | |
| SPLIT TS1 COOLING COIL | 6540.0 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 | |
| SPLIT TS2 COOLING COIL | 6519.4 | 3.16 | 10.78 | 11.20 | 10.60 | 10.53 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 8494.11 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 8305.79 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 9365.09 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 7745.09 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 7090.56 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 7081.07 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 7345.26 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 7399.32 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 20271.86 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 19927.72 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 18734.12 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 18395.16 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 16638.56 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 16616.76 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 17036.29 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 17013.78 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 11382.07 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 11283.00 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 10227.87 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 10128.00 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 9395.32 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 9362.76 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 9510.40 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 9478.02 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 389.34 | 1120.11 | 1.00 | 1.80 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 379.78 | 1120.11 | 1.00 | 1.81 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 413.85 | 1120.11 | 1.00 | 1.76 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 351.29 | 1120.11 | 1.00 | 1.87 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 318.05 | 1120.11 | 1.00 | 1.94 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 317.57 | 1120.11 | 1.00 | 1.94 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 330.99 | 1120.11 | 1.00 | 1.91 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 333.73 | 1120.11 | 1.00 | 1.90 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.84 | 945.39 | 1120.11 | 1.00 | 1.42 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.83 | 927.93 | 1120.11 | 1.00 | 1.42 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.77 | 867.29 | 1120.11 | 1.00 | 1.44 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.76 | 850.08 | 1120.11 | 1.00 | 1.45 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.68 | 760.90 | 1120.11 | 1.00 | 1.49 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.68 | 759.79 | 1120.11 | 1.00 | 1.49 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.70 | 781.09 | 1120.11 | 1.00 | 1.48 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.70 | 779.95 | 1120.11 | 1.00 | 1.48 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.48 | 535.96 | 1120.11 | 1.00 | 1.63 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.47 | 530.94 | 1120.11 | 1.00 | 1.63 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 477.34 | 1120.11 | 1.00 | 1.68 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.42 | 472.28 | 1120.11 | 1.00 | 1.69 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 435.09 | 1120.11 | 1.00 | 1.73 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 433.44 | 1120.11 | 1.00 | 1.73 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 440.93 | 1120.11 | 1.00 | 1.73 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 439.29 | 1120.11 | 1.00 | 1.73 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 3955.24 | 4746.29 | 53.78 | 0.290 | 0.348 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00841 | 30.70 | 0.01447 | 0.026 | 0.00 |
| G NW APARTMENT | 3860.33 | 4632.39 | 52.49 | 0.283 | 0.339 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00840 | 30.70 | 0.01447 | 0.026 | 0.00 |
| OFFICE | 4045.51 | 4854.61 | 55.01 | 0.308 | 0.369 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 23.90 | 23.90 | 0.00826 | 29.71 | 0.01446 | 0.038 | 0.00 |
| G NE APARTMENT | 3576.39 | 4291.67 | 48.63 | 0.261 | 0.314 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00846 | 30.70 | 0.01447 | 0.026 | 0.00 |
| G N1 APARTMENT | 3246.79 | 3896.15 | 44.15 | 0.237 | 0.284 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00838 | 30.70 | 0.01447 | 0.026 | 0.00 |
| G N2 APARTMENT | 3242.04 | 3890.45 | 44.08 | 0.236 | 0.284 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00838 | 30.70 | 0.01447 | 0.026 | 0.00 |
| G S1 APARTMENT | 3374.90 | 4049.88 | 45.89 | 0.246 | 0.295 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00840 | 30.70 | 0.01447 | 0.026 | 0.00 |
| G S2 APARTMENT | 3402.07 | 4082.48 | 46.26 | 0.248 | 0.298 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00840 | 30.70 | 0.01447 | 0.026 | 0.00 |
| M SW APARTMENT | 9562.11 | 11474.53 | 130.02 | 0.703 | 0.844 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00842 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M NW APARTMENT | 9388.26 | 11265.91 | 127.66 | 0.690 | 0.828 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00841 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M SE APARTMENT | 8786.75 | 10544.10 | 119.48 | 0.645 | 0.774 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00847 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M NE APARTMENT | 8616.16 | 10339.39 | 117.16 | 0.632 | 0.759 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00846 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M N1 APARTMENT | 7735.09 | 9282.11 | 105.18 | 0.566 | 0.679 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00838 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M N2 APARTMENT | 7724.17 | 9269.01 | 105.03 | 0.565 | 0.678 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00838 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M S1 APARTMENT | 7934.27 | 9521.13 | 107.89 | 0.581 | 0.697 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00839 | 30.70 | 0.01447 | 0.052 | 0.00 |
| M S2 APARTMENT | 7922.99 | 9507.58 | 107.74 | 0.580 | 0.696 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00839 | 30.70 | 0.01447 | 0.052 | 0.00 |
| T SW APARTMENT | 5412.59 | 6495.11 | 73.60 | 0.399 | 0.478 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00845 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T NW APARTMENT | 5362.75 | 6435.30 | 72.92 | 0.395 | 0.474 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00845 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T SE APARTMENT | 4830.53 | 5796.63 | 65.68 | 0.355 | 0.426 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00851 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T NE APARTMENT | 4779.67 | 5735.61 | 64.99 | 0.351 | 0.422 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00851 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T N1 APARTMENT | 4410.02 | 5292.03 | 59.97 | 0.324 | 0.388 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00837 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T N2 APARTMENT | 4393.60 | 5272.32 | 59.74 | 0.322 | 0.387 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00838 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T S1 APARTMENT | 4468.35 | 5362.02 | 60.76 | 0.328 | 0.394 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00838 | 30.70 | 0.01447 | 0.026 | 0.00 |
| T S2 APARTMENT | 4452.00 | 5342.40 | 60.54 | 0.327 | 0.392 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.00 | 24.00 | 0.00839 | 30.70 | 0.01447 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 2069.17 | 2483.00 | 28.14 | 0.092 | 0.111 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00702 | -6.30 | 0.00230 | 0.026 | 0.00 |
| G NW APARTMENT | 1960.88 | 2353.06 | 26.66 | 0.088 | 0.105 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00707 | -6.30 | 0.00230 | 0.026 | 0.00 |
| OFFICE | 2504.24 | 3005.08 | 34.05 | 0.112 | 0.134 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00717 | -6.30 | 0.00230 | 0.038 | 0.00 |
| G NE APARTMENT | 1953.99 | 2344.79 | 26.57 | 0.087 | 0.105 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00706 | -6.30 | 0.00230 | 0.026 | 0.00 |
| G N1 APARTMENT | 1165.22 | 1398.26 | 15.84 | 0.052 | 0.062 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00712 | -6.30 | 0.00230 | 0.026 | 0.00 |
| G N2 APARTMENT | 1165.01 | 1398.02 | 15.84 | 0.052 | 0.062 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00712 | -6.30 | 0.00230 | 0.026 | 0.00 |
| G S1 APARTMENT | 1275.12 | 1530.14 | 17.34 | 0.057 | 0.068 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00703 | -6.30 | 0.00230 | 0.026 | 0.00 |
| G S2 APARTMENT | 1283.25 | 1539.90 | 17.45 | 0.057 | 0.069 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00703 | -6.30 | 0.00230 | 0.026 | 0.00 |
| M SW APARTMENT | 4146.93 | 4976.31 | 56.39 | 0.185 | 0.222 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00671 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M NW APARTMENT | 3885.56 | 4662.67 | 52.84 | 0.174 | 0.208 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00677 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M SE APARTMENT | 4130.32 | 4956.38 | 56.16 | 0.185 | 0.221 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00671 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M NE APARTMENT | 3868.89 | 4642.67 | 52.61 | 0.173 | 0.207 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00677 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M N1 APARTMENT | 2083.86 | 2500.63 | 28.34 | 0.093 | 0.112 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00675 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M N2 APARTMENT | 2083.42 | 2500.10 | 28.33 | 0.093 | 0.112 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00675 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M S1 APARTMENT | 2338.72 | 2806.46 | 31.80 | 0.105 | 0.125 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00664 | -6.30 | 0.00230 | 0.052 | 0.00 |
| M S2 APARTMENT | 2338.28 | 2805.94 | 31.80 | 0.104 | 0.125 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00664 | -6.30 | 0.00230 | 0.052 | 0.00 |
| T SW APARTMENT | 3441.65 | 4129.98 | 46.80 | 0.154 | 0.185 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00693 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T NW APARTMENT | 3305.41 | 3966.50 | 44.95 | 0.148 | 0.177 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00697 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T SE APARTMENT | 3430.90 | 4117.08 | 46.65 | 0.153 | 0.184 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00692 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T NE APARTMENT | 3294.59 | 3953.51 | 44.80 | 0.147 | 0.177 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00697 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T N1 APARTMENT | 2218.44 | 2662.13 | 30.17 | 0.099 | 0.119 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00710 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T N2 APARTMENT | 2218.14 | 2661.76 | 30.16 | 0.099 | 0.119 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00710 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T S1 APARTMENT | 2355.03 | 2826.03 | 32.02 | 0.105 | 0.126 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00703 | -6.30 | 0.00230 | 0.026 | 0.00 |
| T S2 APARTMENT | 2354.73 | 2825.67 | 32.02 | 0.105 | 0.126 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00703 | -6.30 | 0.00230 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.35 | 0.35 | 0.11 | 0.11 | 0.3476 | 0.3476 | 0.3476 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.34 | 0.34 | 0.11 | 0.11 | 0.3391 | 0.3391 | 0.3391 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.37 | 0.37 | 0.13 | 0.13 | 0.3695 | 0.3695 | 0.3695 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.31 | 0.31 | 0.10 | 0.10 | 0.3136 | 0.3136 | 0.3136 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.28 | 0.28 | 0.06 | 0.06 | 0.2839 | 0.2839 | 0.2839 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.28 | 0.28 | 0.06 | 0.06 | 0.2835 | 0.2835 | 0.2835 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.30 | 0.30 | 0.07 | 0.07 | 0.2955 | 0.2955 | 0.2955 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.30 | 0.30 | 0.07 | 0.07 | 0.2979 | 0.2979 | 0.2979 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.84 | 0.84 | 0.22 | 0.22 | 0.8440 | 0.8440 | 0.8440 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.83 | 0.83 | 0.21 | 0.21 | 0.8284 | 0.8284 | 0.8284 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.77 | 0.77 | 0.22 | 0.22 | 0.7743 | 0.7743 | 0.7743 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.76 | 0.76 | 0.21 | 0.21 | 0.7589 | 0.7589 | 0.7589 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.68 | 0.68 | 0.11 | 0.11 | 0.6793 | 0.6793 | 0.6793 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.68 | 0.68 | 0.11 | 0.11 | 0.6783 | 0.6783 | 0.6783 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.70 | 0.70 | 0.13 | 0.13 | 0.6973 | 0.6973 | 0.6973 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.70 | 0.70 | 0.13 | 0.13 | 0.6963 | 0.6963 | 0.6963 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.48 | 0.48 | 0.18 | 0.18 | 0.4785 | 0.4785 | 0.4785 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.47 | 0.47 | 0.18 | 0.18 | 0.4740 | 0.4740 | 0.4740 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.43 | 0.43 | 0.18 | 0.18 | 0.4262 | 0.4262 | 0.4262 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.42 | 0.42 | 0.18 | 0.18 | 0.4216 | 0.4216 | 0.4216 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.39 | 0.39 | 0.12 | 0.12 | 0.3884 | 0.3884 | 0.3884 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.39 | 0.39 | 0.12 | 0.12 | 0.3870 | 0.3870 | 0.3870 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.39 | 0.39 | 0.13 | 0.13 | 0.3937 | 0.3937 | 0.3937 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.39 | 0.39 | 0.13 | 0.13 | 0.3922 | 0.3922 | 0.3922 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6135.752 | 4913.338 | 0.347590 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5941.88 | 5207.72 | 0.347590 | 25.48 | 16.84 | 0.00886490 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 7.4670 | 24.00 | 0.00841288 | 43.6735 | 3955.24 | 0.00 | 6134.71 | 4817.20 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 8494.112 | 8494.112 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8494.11 | 8494.11 | 0.347590 | 19.05 | 12.50 | 0.00667128 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 7.4670 | 21.10 | 0.00702420 | 43.5836 | 2069.17 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 5991.404 | 4795.562 | 0.339054 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5802.97 | 5084.05 | 0.339054 | 25.49 | 16.84 | 0.00886813 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 7.6550 | 24.00 | 0.00840405 | 43.6280 | 3860.33 | 0.00 | 5990.38 | 4701.79 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 8305.793 | 8305.793 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 8305.79 | 8305.79 | 0.339054 | 19.00 | 12.51 | 0.00670205 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 7.6550 | 21.10 | 0.00706714 | 43.8467 | 1960.88 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 6497.813 | 5198.630 | 0.369475 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 6337.82 | 5524.63 | 0.369475 | 25.44 | 16.85 | 0.00890076 | 12.80 | 11.27 | 0.00800000 | 29.71 | 0.01446471 | 22.27 | 10.3136 | 23.90 | 0.00824784 | 43.0843 | 4000.26 | 0.00 | 6496.71 | 5095.26 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 9365.087 | 9365.087 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 9365.09 | 9365.09 | 0.369475 | 18.27 | 12.19 | 0.00666913 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 10.3136 | 21.10 | 0.00717181 | 44.4891 | 2504.24 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 5621.575 | 4500.271 | 0.313626 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5455.55 | 4723.49 | 0.313626 | 25.53 | 16.92 | 0.00895353 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 8.2757 | 24.00 | 0.00845613 | 43.8950 | 3576.39 | 0.00 | 5620.62 | 4411.39 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 7745.094 | 7745.094 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 7745.09 | 7745.09 | 0.313626 | 18.83 | 12.41 | 0.00666997 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 8.2757 | 21.10 | 0.00706444 | 43.8301 | 1953.99 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 5092.001 | 4075.512 | 0.283947 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4942.08 | 4289.36 | 0.283947 | 25.57 | 16.93 | 0.00893904 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 9.1406 | 24.00 | 0.00838297 | 43.5194 | 3246.79 | 0.00 | 5091.13 | 3995.03 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 7090.557 | 7090.557 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 7090.56 | 7090.56 | 0.283947 | 18.60 | 12.33 | 0.00668281 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 9.1406 | 21.10 | 0.00712396 | 44.1937 | 1165.22 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 5085.593 | 4069.940 | 0.283517 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 4936.04 | 4283.24 | 0.283517 | 25.57 | 16.93 | 0.00894055 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 9.1545 | 24.00 | 0.00838369 | 43.5231 | 3242.04 | 0.00 | 5084.73 | 3989.57 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 7081.072 | 7081.072 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 7081.07 | 7081.07 | 0.283517 | 18.59 | 12.33 | 0.00668203 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 9.1545 | 21.10 | 0.00712383 | 44.1929 | 1165.01 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5292.728 | 4238.330 | 0.295495 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5135.99 | 4458.03 | 0.295495 | 25.56 | 16.92 | 0.00893740 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 8.7834 | 24.00 | 0.00840499 | 43.6326 | 3374.90 | 0.00 | 5291.83 | 4154.62 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 7345.258 | 7345.258 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7345.26 | 7345.26 | 0.295495 | 18.69 | 12.30 | 0.00661326 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 8.7834 | 21.10 | 0.00702881 | 43.6104 | 1275.12 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5329.580 | 4264.910 | 0.297947 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 5170.79 | 4492.83 | 0.297947 | 25.55 | 16.91 | 0.00892987 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 8.7111 | 24.00 | 0.00840154 | 43.6150 | 3402.07 | 0.00 | 5328.67 | 4180.88 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 7399.317 | 7399.317 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7399.32 | 7399.32 | 0.297947 | 18.71 | 12.32 | 0.00662138 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 8.7111 | 21.10 | 0.00703395 | 43.6420 | 1283.25 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 14667.286 | 11736.991 | 0.844021 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 14173.10 | 12551.94 | 0.844021 | 25.41 | 16.75 | 0.00878845 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.1502 | 24.00 | 0.00841636 | 43.6915 | 19124.22 | 0.00 | 14664.79 | 11504.58 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 20271.862 | 20271.862 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 20271.86 | 20271.86 | 0.844021 | 19.41 | 12.42 | 0.00644133 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.1502 | 21.10 | 0.00671287 | 41.6763 | 8293.86 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 14409.668 | 11540.566 | 0.828427 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 13925.95 | 12326.91 | 0.828427 | 25.41 | 16.75 | 0.00879222 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.2660 | 24.00 | 0.00841290 | 43.6737 | 18776.52 | 0.00 | 14407.22 | 11311.37 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 19927.717 | 19927.717 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 19927.72 | 19927.72 | 0.828427 | 19.38 | 12.46 | 0.00649333 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.2660 | 21.10 | 0.00677379 | 42.0497 | 7771.12 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 13643.805 | 10920.262 | 0.774290 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 13209.16 | 11564.32 | 0.774290 | 25.44 | 16.82 | 0.00887008 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.7041 | 24.00 | 0.00846793 | 43.9560 | 17573.50 | 0.00 | 13641.48 | 10702.65 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 18734.123 | 18734.123 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18734.12 | 18734.12 | 0.774290 | 19.26 | 12.33 | 0.00641313 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.7041 | 21.10 | 0.00670886 | 41.6516 | 8260.64 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 13388.113 | 10723.828 | 0.758930 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 12963.65 | 11342.52 | 0.758930 | 25.44 | 16.83 | 0.00887474 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.8398 | 24.00 | 0.00846420 | 43.9367 | 17232.31 | 0.00 | 13385.83 | 10513.93 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 18395.164 | 18395.164 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18395.16 | 18395.16 | 0.758930 | 19.22 | 12.37 | 0.00646389 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.8398 | 21.10 | 0.00676976 | 42.0250 | 7737.78 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 11966.846 | 9579.189 | 0.679309 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11585.59 | 10181.29 | 0.679309 | 25.49 | 16.82 | 0.00884681 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 7.6415 | 24.00 | 0.00838185 | 43.5139 | 15470.18 | 0.00 | 11964.81 | 9388.27 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 16638.555 | 16638.555 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 16638.56 | 16638.56 | 0.679309 | 19.00 | 12.23 | 0.00640755 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 7.6415 | 21.10 | 0.00674758 | 41.8860 | 4167.72 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 11952.305 | 9566.556 | 0.678320 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11571.90 | 10167.30 | 0.678320 | 25.49 | 16.83 | 0.00884818 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 7.6526 | 24.00 | 0.00838261 | 43.5178 | 15448.35 | 0.00 | 11950.27 | 9375.92 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 16616.756 | 16616.756 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 16616.76 | 16616.76 | 0.678320 | 19.00 | 12.22 | 0.00640687 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 7.6526 | 21.10 | 0.00674738 | 41.8847 | 4166.84 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 12268.445 | 9826.129 | 0.697336 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11875.39 | 10441.58 | 0.697336 | 25.48 | 16.82 | 0.00884241 | 12.80 | 11.27 | 0.00800000 | 30.69 | 0.01446650 | 22.54 | 7.4439 | 24.00 | 0.00839009 | 43.5563 | 15868.55 | 0.00 | 12266.36 | 9632.10 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 17036.290 | 17036.290 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17036.29 | 17036.29 | 0.697336 | 19.06 | 12.16 | 0.00631704 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 7.4439 | 21.10 | 0.00664030 | 41.2278 | 4677.43 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 12253.539 | 9813.135 | 0.696315 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 11861.37 | 10427.16 | 0.696315 | 25.48 | 16.82 | 0.00884385 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 7.4548 | 24.00 | 0.00839093 | 43.5606 | 15845.97 | 0.00 | 12251.45 | 9619.40 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 17013.782 | 17013.782 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17013.78 | 17013.78 | 0.696315 | 19.06 | 12.16 | 0.00631639 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 7.4548 | 21.10 | 0.00664010 | 41.2266 | 4676.57 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 8282.610 | 6630.998 | 0.478493 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7999.14 | 7093.86 | 0.478493 | 25.37 | 16.72 | 0.00877708 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 5.4242 | 24.00 | 0.00845078 | 43.8685 | 5412.59 | 0.00 | 8281.20 | 6499.63 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 11382.070 | 11382.070 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11382.07 | 11382.07 | 0.478493 | 19.61 | 12.73 | 0.00667449 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 5.4242 | 21.10 | 0.00692551 | 42.9847 | 3441.65 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 8203.896 | 6568.358 | 0.474007 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7923.00 | 7028.62 | 0.474007 | 25.37 | 16.72 | 0.00877501 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 5.4756 | 24.00 | 0.00844532 | 43.8404 | 5362.75 | 0.00 | 8202.50 | 6438.21 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 11283.001 | 11283.001 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11283.00 | 11283.00 | 0.474007 | 19.60 | 12.76 | 0.00671269 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 5.4756 | 21.10 | 0.00696844 | 43.2475 | 3305.41 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 7500.885 | 6006.493 | 0.426157 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7260.68 | 6351.23 | 0.426157 | 25.41 | 16.82 | 0.00887420 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.0904 | 24.00 | 0.00851152 | 44.1798 | 4830.53 | 0.00 | 7499.61 | 5887.93 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 10227.867 | 10227.867 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10227.87 | 10227.87 | 0.426157 | 19.43 | 12.62 | 0.00664110 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.0904 | 21.10 | 0.00692277 | 42.9679 | 3430.90 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 7420.691 | 5942.482 | 0.421635 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 7182.99 | 6285.05 | 0.421635 | 25.41 | 16.82 | 0.00887240 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.1557 | 24.00 | 0.00850546 | 44.1486 | 4779.67 | 0.00 | 7419.43 | 5825.17 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 10128.003 | 10128.003 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10128.00 | 10128.00 | 0.421635 | 19.41 | 12.65 | 0.00667836 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.1557 | 21.10 | 0.00696571 | 43.2307 | 3294.59 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 6757.005 | 5411.451 | 0.388439 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6530.36 | 5790.60 | 0.388439 | 25.44 | 16.75 | 0.00878167 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.6818 | 24.00 | 0.00837463 | 43.4769 | 4410.02 | 0.00 | 6755.85 | 5303.99 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 9395.323 | 9395.323 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9395.32 | 9395.32 | 0.388439 | 19.27 | 12.69 | 0.00678044 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.6818 | 21.10 | 0.00710141 | 44.0595 | 2218.44 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 6735.059 | 5392.566 | 0.386963 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6509.64 | 5769.66 | 0.386963 | 25.44 | 16.76 | 0.00878482 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.7073 | 24.00 | 0.00837634 | 43.4857 | 4393.60 | 0.00 | 6733.91 | 5285.54 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 9362.760 | 9362.760 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9362.76 | 9362.76 | 0.386963 | 19.26 | 12.69 | 0.00677913 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.7073 | 21.10 | 0.00710131 | 44.0589 | 2218.14 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 6848.704 | 5484.531 | 0.393652 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6619.10 | 5866.69 | 0.393652 | 25.44 | 16.75 | 0.00878448 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.5933 | 24.00 | 0.00838340 | 43.5221 | 4468.35 | 0.00 | 6847.54 | 5375.63 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 9510.402 | 9510.402 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9510.40 | 9510.40 | 0.393652 | 19.29 | 12.64 | 0.00671879 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.5933 | 21.10 | 0.00703086 | 43.6275 | 2355.03 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 6826.920 | 5465.769 | 0.392183 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 6598.54 | 5845.87 | 0.392183 | 25.44 | 16.76 | 0.00878762 | 12.80 | 11.27 | 0.00800000 | 30.70 | 0.01446650 | 22.54 | 6.6180 | 24.00 | 0.00838516 | 43.5311 | 4452.00 | 0.00 | 6825.76 | 5357.31 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 9478.018 | 9478.018 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9478.02 | 9478.02 | 0.392183 | 19.28 | 12.64 | 0.00671753 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 6.6180 | 21.10 | 0.00703075 | 43.6268 | 2354.73 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6135.752 | 4913.338 | 0.347590 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3194 | 1004.8586 | 1.1610 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.347590 | 0.40354431 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5941.88 | 5207.72 | 0.9684 | 0.40354431 | 0.347590 | 25.48 | 16.84 | 0.00886490 | 48196.0 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 389.339 | 5552.55 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 7.4670 | 24.04 | 0.00841288 | 24.00 | 0.00841288 | 43.6735 | 3955.24 | 0.00 | 6134.71 | 4817.20 | 0.38760736 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.52 | 14.09 | 0.00985196 | 39495.3 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8494.112 | 8494.112 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.347590 | 0.40354431 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8494.11 | 8494.11 | 1.0000 | 0.40354431 | 0.347590 | 19.05 | 12.50 | 0.00667128 | 36066.0 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8494.11 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 7.4670 | 21.10 | 0.00702420 | 21.10 | 0.00702420 | 43.5836 | 2069.17 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5991.404 | 4795.562 | 0.339054 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3254 | 1004.8586 | 1.1610 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.339054 | 0.39363364 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5802.97 | 5084.05 | 0.9685 | 0.39363364 | 0.339054 | 25.49 | 16.84 | 0.00886813 | 48214.9 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 379.777 | 5423.20 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 7.6550 | 24.04 | 0.00840405 | 24.00 | 0.00840405 | 43.6280 | 3860.33 | 0.00 | 5990.38 | 4701.79 | 0.37808808 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 14.08 | 0.00984839 | 39478.5 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8305.793 | 8305.793 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.339054 | 0.39363364 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 8305.79 | 8305.79 | 1.0000 | 0.39363364 | 0.339054 | 19.00 | 12.51 | 0.00670205 | 36091.8 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8305.79 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 7.6550 | 21.10 | 0.00706714 | 21.10 | 0.00706714 | 43.8467 | 1960.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6497.813 | 5198.630 | 0.369475 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3861 | 1004.8586 | 1.1610 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.369475 | 0.42895143 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | Sensible | 6337.82 | 5524.63 | 0.9754 | 0.42895143 | 0.369475 | 25.44 | 16.85 | 0.00890076 | 48247.3 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 413.852 | 5923.97 | 29.71 | 0.01446471 | 22.27 | 0.03810604 | 10.3136 | 23.90 | 0.00826093 | 23.90 | 0.00824784 | 43.0843 | 4000.26 | 0.00 | 6496.71 | 5095.26 | 0.41201109 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.58 | 14.11 | 0.00985102 | 39554.1 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9365.087 | 9365.087 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.369475 | 0.42895143 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 9365.09 | 9365.09 | 1.0000 | 0.42895143 | 0.369475 | 18.27 | 12.19 | 0.00666913 | 35267.1 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9365.09 | -6.30 | 0.00229779 | -6.30 | 0.03810604 | 10.3136 | 21.10 | 0.00717181 | 21.10 | 0.00717181 | 44.4891 | 2504.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5621.575 | 4500.271 | 0.313626 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4842 | 1004.8586 | 1.1610 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.313626 | 0.36411186 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5455.55 | 4723.49 | 0.9705 | 0.36411186 | 0.313626 | 25.53 | 16.92 | 0.00895353 | 48466.8 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 351.294 | 5104.25 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 8.2757 | 24.03 | 0.00845613 | 24.00 | 0.00845613 | 43.8950 | 3576.39 | 0.00 | 5620.62 | 4411.39 | 0.34973219 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.34 | 14.00 | 0.00982902 | 39251.2 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7745.094 | 7745.094 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.313626 | 0.36411186 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 7745.09 | 7745.09 | 1.0000 | 0.36411186 | 0.313626 | 18.83 | 12.41 | 0.00666997 | 35837.5 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7745.09 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 8.2757 | 21.10 | 0.00706444 | 21.10 | 0.00706444 | 43.8301 | 1953.99 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5092.001 | 4075.512 | 0.283947 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4572 | 1004.8586 | 1.1610 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.283947 | 0.32965540 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4942.08 | 4289.36 | 0.9706 | 0.32965540 | 0.283947 | 25.57 | 16.93 | 0.00893904 | 48477.5 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 318.051 | 4624.03 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 9.1406 | 24.02 | 0.00838297 | 24.00 | 0.00838297 | 43.5194 | 3246.79 | 0.00 | 5091.13 | 3995.03 | 0.31663650 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.33 | 14.00 | 0.00982740 | 39243.6 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7090.557 | 7090.557 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.283947 | 0.32965540 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 7090.56 | 7090.56 | 1.0000 | 0.32965540 | 0.283947 | 18.60 | 12.33 | 0.00668281 | 35629.3 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7090.56 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 9.1406 | 21.10 | 0.00712396 | 21.10 | 0.00712396 | 44.1937 | 1165.22 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5085.593 | 4069.940 | 0.283517 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4600 | 1004.8586 | 1.1610 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.283517 | 0.32915601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 4936.04 | 4283.24 | 0.9706 | 0.32915601 | 0.283517 | 25.57 | 16.93 | 0.00894055 | 48482.1 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 317.569 | 4618.47 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 9.1545 | 24.02 | 0.00838369 | 24.00 | 0.00838369 | 43.5231 | 3242.04 | 0.00 | 5084.73 | 3989.57 | 0.31615683 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.33 | 13.99 | 0.00982652 | 39239.5 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7081.072 | 7081.072 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.283517 | 0.32915601 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 7081.07 | 7081.07 | 1.0000 | 0.32915601 | 0.283517 | 18.59 | 12.33 | 0.00668203 | 35623.5 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7081.07 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 9.1545 | 21.10 | 0.00712383 | 21.10 | 0.00712383 | 44.1929 | 1165.01 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5292.728 | 4238.330 | 0.295495 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4542 | 1004.8586 | 1.1610 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.295495 | 0.34306274 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5135.99 | 4458.03 | 0.9704 | 0.34306274 | 0.295495 | 25.56 | 16.92 | 0.00893740 | 48455.3 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 330.986 | 4805.00 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 8.7834 | 24.02 | 0.00840499 | 24.00 | 0.00840499 | 43.6326 | 3374.90 | 0.00 | 5291.83 | 4154.62 | 0.32951436 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.34 | 14.00 | 0.00983154 | 39262.9 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7345.258 | 7345.258 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.295495 | 0.34306274 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7345.26 | 7345.26 | 1.0000 | 0.34306274 | 0.295495 | 18.69 | 12.30 | 0.00661326 | 35552.3 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7345.26 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 8.7834 | 21.10 | 0.00702881 | 21.10 | 0.00702881 | 43.6104 | 1275.12 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5329.580 | 4264.910 | 0.297947 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4402 | 1004.8586 | 1.1610 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.297947 | 0.34590908 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 5170.79 | 4492.83 | 0.9702 | 0.34590908 | 0.297947 | 25.55 | 16.91 | 0.00892987 | 48431.6 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 333.732 | 4837.06 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 8.7111 | 24.03 | 0.00840154 | 24.00 | 0.00840154 | 43.6150 | 3402.07 | 0.00 | 5328.67 | 4180.88 | 0.33224829 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.37 | 14.01 | 0.00983019 | 39284.2 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7399.317 | 7399.317 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.297947 | 0.34590908 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7399.32 | 7399.32 | 1.0000 | 0.34590908 | 0.297947 | 18.71 | 12.32 | 0.00662138 | 35593.1 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7399.32 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 8.7111 | 21.10 | 0.00703395 | 21.10 | 0.00703395 | 43.6420 | 1283.25 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14667.286 | 11736.991 | 0.844021 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1773 | 1004.8586 | 1.1610 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.844021 | 0.97988875 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 14173.10 | 12551.94 | 0.9663 | 0.97988875 | 0.844021 | 25.41 | 16.75 | 0.00878845 | 47922.6 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 945.395 | 13227.70 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 6.1502 | 24.05 | 0.00841636 | 24.00 | 0.00841636 | 43.6915 | 19124.22 | 0.00 | 14664.79 | 11504.58 | 0.94119055 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.72 | 14.18 | 0.00986819 | 39741.3 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20271.862 | 20271.862 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.844021 | 0.97988875 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 20271.86 | 20271.86 | 1.0000 | 0.97988875 | 0.844021 | 19.41 | 12.42 | 0.00644133 | 35847.9 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20271.86 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 6.1502 | 21.10 | 0.00671287 | 21.10 | 0.00671287 | 41.6763 | 8293.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14409.668 | 11540.566 | 0.828427 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1843 | 1004.8586 | 1.1610 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.828427 | 0.96178404 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 13925.95 | 12326.91 | 0.9664 | 0.96178404 | 0.828427 | 25.41 | 16.75 | 0.00879222 | 47938.8 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 927.927 | 12998.03 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 6.2660 | 24.05 | 0.00841290 | 24.00 | 0.00841290 | 43.6737 | 18776.52 | 0.00 | 14407.22 | 11311.37 | 0.92380085 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 14.18 | 0.00987073 | 39726.8 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 19927.717 | 19927.717 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.828427 | 0.96178404 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 19927.72 | 19927.72 | 1.0000 | 0.96178404 | 0.828427 | 19.38 | 12.46 | 0.00649333 | 35947.8 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19927.72 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 6.2660 | 21.10 | 0.00677379 | 21.10 | 0.00677379 | 42.0497 | 7771.12 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13643.805 | 10920.262 | 0.774290 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3290 | 1004.8586 | 1.1610 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.774290 | 0.89893286 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 13209.16 | 11564.32 | 0.9681 | 0.89893286 | 0.774290 | 25.44 | 16.82 | 0.00887008 | 48163.1 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 867.289 | 12341.87 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 6.7041 | 24.05 | 0.00846793 | 24.00 | 0.00846793 | 43.9560 | 17573.50 | 0.00 | 13641.48 | 10702.65 | 0.86343181 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.55 | 14.10 | 0.00985016 | 39523.2 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18734.123 | 18734.123 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.774290 | 0.89893286 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18734.12 | 18734.12 | 1.0000 | 0.89893286 | 0.774290 | 19.26 | 12.33 | 0.00641313 | 35622.1 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18734.12 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 6.7041 | 21.10 | 0.00670886 | 21.10 | 0.00670886 | 41.6516 | 8260.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13388.113 | 10723.828 | 0.758930 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3377 | 1004.8586 | 1.1610 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.758930 | 0.88109995 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 12963.65 | 11342.52 | 0.9683 | 0.88109995 | 0.758930 | 25.44 | 16.83 | 0.00887474 | 48182.9 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 850.084 | 12113.57 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 6.8398 | 24.05 | 0.00846420 | 24.00 | 0.00846420 | 43.9367 | 17232.31 | 0.00 | 13385.83 | 10513.93 | 0.84630316 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.52 | 14.09 | 0.00985416 | 39505.6 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18395.164 | 18395.164 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.758930 | 0.88109995 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18395.16 | 18395.16 | 1.0000 | 0.88109995 | 0.758930 | 19.22 | 12.37 | 0.00646389 | 35713.3 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18395.16 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 6.8398 | 21.10 | 0.00676976 | 21.10 | 0.00676976 | 42.0250 | 7737.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11966.846 | 9579.189 | 0.679309 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2858 | 1004.8586 | 1.1610 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.679309 | 0.78866168 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11585.59 | 10181.29 | 0.9681 | 0.78866168 | 0.679309 | 25.49 | 16.82 | 0.00884681 | 48161.0 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 760.899 | 10824.69 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 7.6415 | 24.04 | 0.00838185 | 24.00 | 0.00838185 | 43.5139 | 15470.18 | 0.00 | 11964.81 | 9388.27 | 0.75751551 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.55 | 14.10 | 0.00985109 | 39527.6 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16638.555 | 16638.555 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.679309 | 0.78866168 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 16638.56 | 16638.56 | 1.0000 | 0.78866168 | 0.679309 | 19.00 | 12.23 | 0.00640755 | 35348.1 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16638.56 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 7.6415 | 21.10 | 0.00674758 | 21.10 | 0.00674758 | 41.8860 | 4167.72 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11952.305 | 9566.556 | 0.678320 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2883 | 1004.8586 | 1.1610 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.678320 | 0.78751395 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11571.90 | 10167.30 | 0.9682 | 0.78751395 | 0.678320 | 25.49 | 16.83 | 0.00884818 | 48165.2 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 759.792 | 10812.10 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 7.6526 | 24.04 | 0.00838261 | 24.00 | 0.00838261 | 43.5178 | 15448.35 | 0.00 | 11950.27 | 9375.92 | 0.75641310 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.55 | 14.10 | 0.00985028 | 39523.8 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16616.756 | 16616.756 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.678320 | 0.78751395 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 16616.76 | 16616.76 | 1.0000 | 0.78751395 | 0.678320 | 19.00 | 12.22 | 0.00640687 | 35343.2 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16616.76 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 7.6526 | 21.10 | 0.00674738 | 21.10 | 0.00674738 | 41.8847 | 4166.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12268.445 | 9826.129 | 0.697336 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2776 | 1004.8586 | 1.1610 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.697336 | 0.80959065 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11875.39 | 10441.58 | 0.9680 | 0.80959065 | 0.697336 | 25.48 | 16.82 | 0.00884241 | 48137.9 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 781.092 | 11094.30 | 30.69 | 0.01446650 | 22.54 | 0.05190911 | 7.4439 | 24.04 | 0.00839009 | 24.00 | 0.00839009 | 43.5563 | 15868.55 | 0.00 | 12266.36 | 9632.10 | 0.77761794 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.56 | 14.11 | 0.00985646 | 39548.1 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17036.290 | 17036.290 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.697336 | 0.80959065 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17036.29 | 17036.29 | 1.0000 | 0.80959065 | 0.697336 | 19.06 | 12.16 | 0.00631704 | 35173.3 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17036.29 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 7.4439 | 21.10 | 0.00664030 | 21.10 | 0.00664030 | 41.2278 | 4677.43 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12253.539 | 9813.135 | 0.696315 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2803 | 1004.8586 | 1.1610 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.696315 | 0.80840563 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 11861.37 | 10427.16 | 0.9680 | 0.80840563 | 0.696315 | 25.48 | 16.82 | 0.00884385 | 48142.2 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 779.948 | 11081.43 | 30.70 | 0.01446650 | 22.54 | 0.05190911 | 7.4548 | 24.04 | 0.00839093 | 24.00 | 0.00839093 | 43.5606 | 15845.97 | 0.00 | 12251.45 | 9619.40 | 0.77647972 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.56 | 14.11 | 0.00985563 | 39544.2 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17013.782 | 17013.782 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.696315 | 0.80840563 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17013.78 | 17013.78 | 1.0000 | 0.80840563 | 0.696315 | 19.06 | 12.16 | 0.00631639 | 35168.6 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17013.78 | -6.30 | 0.00229779 | -6.30 | 0.05190911 | 7.4548 | 21.10 | 0.00664010 | 21.10 | 0.00664010 | 41.2266 | 4676.57 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8282.610 | 6630.998 | 0.478493 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1562 | 1004.8586 | 1.1610 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.478493 | 0.55551883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7999.14 | 7093.86 | 0.9658 | 0.55551883 | 0.478493 | 25.37 | 16.72 | 0.00877708 | 47854.1 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 535.964 | 7463.18 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 5.4242 | 24.06 | 0.00845078 | 24.00 | 0.00845078 | 43.8685 | 5412.59 | 0.00 | 8281.20 | 6499.63 | 0.53358003 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.76 | 14.21 | 0.00987555 | 39802.3 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11382.070 | 11382.070 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.478493 | 0.55551883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11382.07 | 11382.07 | 1.0000 | 0.55551883 | 0.478493 | 19.61 | 12.73 | 0.00667449 | 36640.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11382.07 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 5.4242 | 21.10 | 0.00692551 | 21.10 | 0.00692551 | 42.9847 | 3441.65 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8203.896 | 6568.358 | 0.474007 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1523 | 1004.8586 | 1.1610 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.474007 | 0.55031138 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7923.00 | 7028.62 | 0.9658 | 0.55031138 | 0.474007 | 25.37 | 16.72 | 0.00877501 | 47852.0 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 530.939 | 7392.06 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 5.4756 | 24.06 | 0.00844532 | 24.00 | 0.00844532 | 43.8404 | 5362.75 | 0.00 | 8202.50 | 6438.21 | 0.52857824 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.76 | 14.21 | 0.00987598 | 39804.3 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11283.001 | 11283.001 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.474007 | 0.55031138 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11283.00 | 11283.00 | 1.0000 | 0.55031138 | 0.474007 | 19.60 | 12.76 | 0.00671269 | 36723.6 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11283.00 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 5.4756 | 21.10 | 0.00696844 | 21.10 | 0.00696844 | 43.2475 | 3305.41 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7500.885 | 6006.493 | 0.426157 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3367 | 1004.8586 | 1.1610 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.426157 | 0.49475797 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7260.68 | 6351.23 | 0.9680 | 0.49475797 | 0.426157 | 25.41 | 16.82 | 0.00887420 | 48142.1 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 477.342 | 6783.34 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 6.0904 | 24.06 | 0.00851152 | 24.00 | 0.00851152 | 44.1798 | 4830.53 | 0.00 | 7499.61 | 5887.93 | 0.47521877 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.56 | 14.11 | 0.00985495 | 39541.0 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10227.867 | 10227.867 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.426157 | 0.49475797 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10227.87 | 10227.87 | 1.0000 | 0.49475797 | 0.426157 | 19.43 | 12.62 | 0.00664110 | 36370.3 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10227.87 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 6.0904 | 21.10 | 0.00692277 | 21.10 | 0.00692277 | 42.9679 | 3430.90 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7420.691 | 5942.482 | 0.421635 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3334 | 1004.8586 | 1.1610 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.421635 | 0.48950779 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 7182.99 | 6285.05 | 0.9680 | 0.48950779 | 0.421635 | 25.41 | 16.82 | 0.00887240 | 48140.8 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 472.276 | 6710.72 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 6.1557 | 24.06 | 0.00850546 | 24.00 | 0.00850546 | 44.1486 | 4779.67 | 0.00 | 7419.43 | 5825.17 | 0.47017593 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.56 | 14.11 | 0.00985522 | 39542.3 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10128.003 | 10128.003 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.421635 | 0.48950779 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10128.00 | 10128.00 | 1.0000 | 0.48950779 | 0.421635 | 19.41 | 12.65 | 0.00667836 | 36447.0 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10128.00 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 6.1557 | 21.10 | 0.00696571 | 21.10 | 0.00696571 | 43.2307 | 3294.59 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6757.005 | 5411.451 | 0.388439 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1647 | 1004.8586 | 1.1610 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.388439 | 0.45096889 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6530.36 | 5790.60 | 0.9665 | 0.45096889 | 0.388439 | 25.44 | 16.75 | 0.00878167 | 47941.4 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 435.094 | 6095.27 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 6.6818 | 24.05 | 0.00837463 | 24.00 | 0.00837463 | 43.4769 | 4410.02 | 0.00 | 6755.85 | 5303.99 | 0.43315902 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 14.18 | 0.00987049 | 39725.7 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9395.323 | 9395.323 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.388439 | 0.45096889 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9395.32 | 9395.32 | 1.0000 | 0.45096889 | 0.388439 | 19.27 | 12.69 | 0.00678044 | 36560.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9395.32 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 6.6818 | 21.10 | 0.00710141 | 21.10 | 0.00710141 | 44.0595 | 2218.44 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6735.059 | 5392.566 | 0.386963 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1705 | 1004.8586 | 1.1610 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.386963 | 0.44925447 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6509.64 | 5769.66 | 0.9665 | 0.44925447 | 0.386963 | 25.44 | 16.76 | 0.00878482 | 47950.9 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 433.440 | 6076.20 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 6.7073 | 24.05 | 0.00837634 | 24.00 | 0.00837634 | 43.4857 | 4393.60 | 0.00 | 6733.91 | 5285.54 | 0.43151232 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 14.17 | 0.00986865 | 39717.0 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9362.760 | 9362.760 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.386963 | 0.44925447 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9362.76 | 9362.76 | 1.0000 | 0.44925447 | 0.386963 | 19.26 | 12.69 | 0.00677913 | 36550.2 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9362.76 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 6.7073 | 21.10 | 0.00710131 | 21.10 | 0.00710131 | 44.0589 | 2218.14 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6848.704 | 5484.531 | 0.393652 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1699 | 1004.8586 | 1.1610 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.393652 | 0.45702070 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6619.10 | 5866.69 | 0.9665 | 0.45702070 | 0.393652 | 25.44 | 16.75 | 0.00878448 | 47943.7 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 440.933 | 6178.16 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 6.5933 | 24.05 | 0.00838340 | 24.00 | 0.00838340 | 43.5221 | 4468.35 | 0.00 | 6847.54 | 5375.63 | 0.43897183 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.70 | 14.18 | 0.00987000 | 39723.3 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9510.402 | 9510.402 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.393652 | 0.45702070 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9510.40 | 9510.40 | 1.0000 | 0.45702070 | 0.393652 | 19.29 | 12.64 | 0.00671879 | 36428.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9510.40 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 6.5933 | 21.10 | 0.00703086 | 21.10 | 0.00703086 | 43.6275 | 2355.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6826.920 | 5465.769 | 0.392183 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1758 | 1004.8586 | 1.1610 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.392183 | 0.45531577 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | Sensible | 6598.54 | 5845.87 | 0.9665 | 0.45531577 | 0.392183 | 25.44 | 16.76 | 0.00878762 | 47953.2 | 12.80 | 11.27 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 439.288 | 6159.25 | 30.70 | 0.01446650 | 22.54 | 0.02595455 | 6.6180 | 24.05 | 0.00838516 | 24.00 | 0.00838516 | 43.5311 | 4452.00 | 0.00 | 6825.76 | 5357.31 | 0.43733424 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.69 | 14.17 | 0.00986817 | 39714.7 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9478.018 | 9478.018 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.392183 | 0.45531577 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9478.02 | 9478.02 | 1.0000 | 0.45531577 | 0.392183 | 19.28 | 12.64 | 0.00671753 | 36418.6 | 40.00 | 20.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9478.02 | -6.30 | 0.00229779 | -6.30 | 0.02595455 | 6.6180 | 21.10 | 0.00703075 | 21.10 | 0.00703075 | 43.6268 | 2354.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 3234.17 | 4192.50 | 1782.67 |
| G NW APARTMENT | 5011.67 | 6240.33 | 3064.00 |
| OFFICE | 1104.83 | 813.33 | 336.17 |
| G NE APARTMENT | 5018.67 | 6191.67 | 3023.50 |
| G N1 APARTMENT | 4617.50 | 6079.17 | 2632.17 |
| G N2 APARTMENT | 4620.50 | 6074.83 | 2627.67 |
| G S1 APARTMENT | 2992.00 | 3962.67 | 1433.83 |
| G S2 APARTMENT | 3104.00 | 3724.67 | 1345.17 |
| M SW APARTMENT | 3146.00 | 3692.83 | 1364.17 |
| M NW APARTMENT | 4832.50 | 5560.33 | 2409.67 |
| M SE APARTMENT | 3129.83 | 3714.33 | 1386.50 |
| M NE APARTMENT | 4813.83 | 5500.50 | 2362.00 |
| M N1 APARTMENT | 4486.67 | 5337.67 | 2062.33 |
| M N2 APARTMENT | 4488.33 | 5337.17 | 2060.33 |
| M S1 APARTMENT | 2951.83 | 3429.50 | 1097.00 |
| M S2 APARTMENT | 2951.67 | 3429.83 | 1098.83 |
| T SW APARTMENT | 3761.50 | 4342.33 | 2338.67 |
| T NW APARTMENT | 5660.17 | 6195.83 | 3540.83 |
| T SE APARTMENT | 3745.67 | 4377.67 | 2360.50 |
| T NE APARTMENT | 5667.50 | 6152.00 | 3486.50 |
| T N1 APARTMENT | 5397.33 | 6095.00 | 3269.83 |
| T N2 APARTMENT | 5400.17 | 6091.67 | 3270.00 |
| T S1 APARTMENT | 3502.50 | 4206.33 | 2049.33 |
| T S2 APARTMENT | 3504.33 | 4207.33 | 2051.67 |
| T CORRIDOR | 6647.50 | 8534.33 | 6502.00 |
| G CORRIDOR | 6076.83 | 7580.50 | 5191.00 |
| M CORRIDOR | 6470.33 | 8509.83 | 6328.00 |
| Facility | 8459.67 | 8760.00 | 8342.67 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.170 | 0.000 | 0.058 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.179 | 0.000 | 0.070 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.519 | 0.200 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.179 | 0.000 | 0.070 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.108 | 0.000 | 0.071 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.108 | 0.000 | 0.071 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.102 | 0.000 | 0.058 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.102 | 0.000 | 0.058 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.244 | 0.000 | 0.071 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.257 | 0.000 | 0.088 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.244 | 0.000 | 0.071 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.257 | 0.000 | 0.088 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.155 | 0.000 | 0.088 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.155 | 0.000 | 0.088 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.147 | 0.000 | 0.071 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.354 | 0.147 | 0.000 | 0.071 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.322 | 0.000 | 0.082 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.340 | 0.000 | 0.103 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.322 | 0.000 | 0.083 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.340 | 0.000 | 0.103 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.205 | 0.000 | 0.103 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.205 | 0.000 | 0.103 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.195 | 0.000 | 0.083 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.195 | 0.000 | 0.083 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.494 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.339 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.17 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 168694.61 | 987197.39 | 415477.97 | 1402675.36 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 2615.00 |
| G NW APARTMENT | 818502.78 | 161747.73 | 980250.51 | 415477.97 | 1395728.48 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 415477.97 | 1617189.94 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 161841.01 | 980343.78 | 415477.97 | 1395821.76 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 0.00 |
| G N1 APARTMENT | 818502.78 | 163029.84 | 981532.62 | 250605.77 | 1232138.38 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 0.00 |
| G N2 APARTMENT | 818502.78 | 163034.23 | 981537.01 | 250605.77 | 1232142.77 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 0.00 |
| G S1 APARTMENT | 818502.78 | 170338.74 | 988841.51 | 250605.77 | 1239447.28 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 170546.85 | 989049.63 | 250605.77 | 1239655.39 | 818502.78 | 0.00 | 6870.00 | 1890.00 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 210342.04 | 1847347.60 | 597073.61 | 2444421.21 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 202948.15 | 1839953.71 | 597073.61 | 2437027.31 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 0.00 |
| M SE APARTMENT | 1637005.55 | 210486.29 | 1847491.84 | 597073.61 | 2444565.45 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 203145.68 | 1840151.24 | 597073.61 | 2437224.85 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 203850.64 | 1840856.19 | 360139.64 | 2200995.83 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 203867.25 | 1840872.81 | 360139.64 | 2201012.45 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 211151.65 | 1848157.21 | 360139.64 | 2208296.85 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 211158.39 | 1848163.94 | 360139.64 | 2208303.59 | 1637005.55 | 0.00 | 6828.50 | 1931.50 | 2615.00 |
| T SW APARTMENT | 818502.78 | 246241.09 | 1064743.87 | 789805.06 | 1854548.92 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 2615.00 |
| T NW APARTMENT | 818502.78 | 237330.01 | 1055832.79 | 789805.06 | 1845637.85 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 0.00 |
| T SE APARTMENT | 818502.78 | 246881.48 | 1065384.26 | 789805.06 | 1855189.32 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 2615.00 |
| T NE APARTMENT | 818502.78 | 237814.49 | 1056317.27 | 789805.06 | 1846122.33 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 0.00 |
| T N1 APARTMENT | 818502.78 | 237870.94 | 1056373.72 | 476390.36 | 1532764.08 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 0.00 |
| T N2 APARTMENT | 818502.78 | 237910.16 | 1056412.94 | 476390.36 | 1532803.30 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 0.00 |
| T S1 APARTMENT | 818502.78 | 247338.00 | 1065840.78 | 476390.36 | 1542231.14 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 247364.95 | 1065867.73 | 476390.36 | 1542258.09 | 818502.78 | 0.00 | 6855.33 | 1904.67 | 2615.00 |
| Total Facility | 39671342.50 | 6411884.33 | 46083226.83 | 15386822.62 | 61470049.45 | 39671342.50 | 0.00 | 8760.00 | 1935.33 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0042 | 0.0302 | 0.0125 | 0.0427 | 0.0260 | 0.00 | 5055.33 | 1089.67 |
| G NW APARTMENT | 0.0260 | 0.0051 | 0.0311 | 0.0132 | 0.0443 | 0.0260 | 0.00 | 6870.00 | 1890.00 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0147 | 0.0528 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0051 | 0.0311 | 0.0132 | 0.0443 | 0.0260 | 0.00 | 6870.00 | 1890.00 |
| G N1 APARTMENT | 0.0260 | 0.0052 | 0.0311 | 0.0079 | 0.0391 | 0.0260 | 0.00 | 6870.00 | 1890.00 |
| G N2 APARTMENT | 0.0260 | 0.0052 | 0.0311 | 0.0079 | 0.0391 | 0.0260 | 0.00 | 6870.00 | 1890.00 |
| G S1 APARTMENT | 0.0260 | 0.0043 | 0.0302 | 0.0075 | 0.0377 | 0.0260 | 0.00 | 5055.33 | 1089.67 |
| G S2 APARTMENT | 0.0260 | 0.0043 | 0.0302 | 0.0075 | 0.0377 | 0.0260 | 0.00 | 5055.33 | 1089.67 |
| M SW APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0179 | 0.0750 | 0.0519 | 0.00 | 5032.00 | 1113.00 |
| M NW APARTMENT | 0.0519 | 0.0064 | 0.0583 | 0.0189 | 0.0773 | 0.0519 | 0.00 | 6828.50 | 1931.50 |
| M SE APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0179 | 0.0750 | 0.0519 | 0.00 | 5032.00 | 1113.00 |
| M NE APARTMENT | 0.0519 | 0.0064 | 0.0584 | 0.0189 | 0.0773 | 0.0519 | 0.00 | 6828.50 | 1931.50 |
| M N1 APARTMENT | 0.0519 | 0.0065 | 0.0584 | 0.0114 | 0.0698 | 0.0519 | 0.00 | 6828.50 | 1931.50 |
| M N2 APARTMENT | 0.0519 | 0.0065 | 0.0584 | 0.0114 | 0.0698 | 0.0519 | 0.00 | 6828.50 | 1931.50 |
| M S1 APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0108 | 0.0679 | 0.0519 | 0.00 | 5032.00 | 1113.00 |
| M S2 APARTMENT | 0.0519 | 0.0052 | 0.0571 | 0.0108 | 0.0679 | 0.0519 | 0.00 | 5032.00 | 1113.00 |
| T SW APARTMENT | 0.0260 | 0.0060 | 0.0320 | 0.0237 | 0.0557 | 0.0260 | 0.00 | 5045.00 | 1100.00 |
| T NW APARTMENT | 0.0260 | 0.0075 | 0.0335 | 0.0250 | 0.0585 | 0.0260 | 0.00 | 6855.33 | 1904.67 |
| T SE APARTMENT | 0.0260 | 0.0060 | 0.0320 | 0.0237 | 0.0557 | 0.0260 | 0.00 | 5045.00 | 1100.00 |
| T NE APARTMENT | 0.0260 | 0.0075 | 0.0335 | 0.0250 | 0.0585 | 0.0260 | 0.00 | 6855.33 | 1904.67 |
| T N1 APARTMENT | 0.0260 | 0.0075 | 0.0335 | 0.0151 | 0.0486 | 0.0260 | 0.00 | 6855.33 | 1904.67 |
| T N2 APARTMENT | 0.0260 | 0.0075 | 0.0335 | 0.0151 | 0.0486 | 0.0260 | 0.00 | 6855.33 | 1904.67 |
| T S1 APARTMENT | 0.0260 | 0.0060 | 0.0320 | 0.0143 | 0.0463 | 0.0260 | 0.00 | 5045.00 | 1100.00 |
| T S2 APARTMENT | 0.0260 | 0.0060 | 0.0320 | 0.0143 | 0.0463 | 0.0260 | 0.00 | 5045.00 | 1100.00 |
| Total Facility | 1.2580 | 0.1807 | 1.4387 | 0.4773 | 1.9159 | 1.2580 | 0.00 | 8760.00 | 1935.33 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 168694.61 | 168694.61 | 818502.78 | 7866.75 | 50.89 | 842.36 | 800.33 |
| SPLIT GNW | 0.00 | 161747.73 | 161747.73 | 818502.78 | 7997.08 | 59.00 | 703.92 | 0.00 |
| SPLIT OFFICE | 1619747.34 | 0.00 | 1619747.34 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 161841.01 | 161841.01 | 818502.78 | 7999.66 | 57.51 | 702.83 | 0.00 |
| SPLIT GN1 | 0.00 | 163029.84 | 163029.84 | 818502.78 | 7973.21 | 53.71 | 733.08 | 0.00 |
| SPLIT GN2 | 0.00 | 163034.23 | 163034.23 | 818502.78 | 7972.98 | 54.19 | 732.83 | 0.00 |
| SPLIT GS1 | 0.00 | 170338.74 | 170338.74 | 818502.78 | 7847.00 | 47.50 | 865.50 | 800.33 |
| SPLIT GS2 | 0.00 | 170546.85 | 170546.85 | 818502.78 | 7844.08 | 47.25 | 868.67 | 800.33 |
| SPLIT MSW | 0.00 | 210342.04 | 210342.04 | 1637005.55 | 8715.50 | 7.50 | 37.00 | 818.50 |
| SPLIT MNW | 0.00 | 202948.15 | 202948.15 | 1637005.55 | 8728.00 | 5.33 | 26.67 | 0.00 |
| SPLIT MSE | 0.00 | 210486.29 | 210486.29 | 1637005.55 | 8715.33 | 7.17 | 37.50 | 818.50 |
| SPLIT MNE | 0.00 | 203145.68 | 203145.68 | 1637005.55 | 8727.67 | 5.83 | 26.50 | 0.00 |
| SPLIT MN1 | 0.00 | 203850.64 | 203850.64 | 1637005.55 | 8727.00 | 5.83 | 27.17 | 0.00 |
| SPLIT MN2 | 0.00 | 203867.25 | 203867.25 | 1637005.55 | 8727.00 | 5.67 | 27.33 | 0.00 |
| SPLIT MS1 | 0.00 | 211151.65 | 211151.65 | 1637005.55 | 8714.17 | 6.67 | 39.17 | 818.50 |
| SPLIT MS2 | 0.00 | 211158.39 | 211158.39 | 1637005.55 | 8714.00 | 6.75 | 39.25 | 818.50 |
| SPLIT TSW | 0.00 | 246241.09 | 246241.09 | 818502.78 | 7231.29 | 25.38 | 1503.33 | 804.67 |
| SPLIT TNW | 0.00 | 237330.01 | 237330.01 | 818502.78 | 7299.75 | 34.47 | 1425.78 | 0.00 |
| SPLIT TSE | 0.00 | 246881.48 | 246881.48 | 818502.78 | 7226.13 | 24.29 | 1509.58 | 804.67 |
| SPLIT TNE | 0.00 | 237814.49 | 237814.49 | 818502.78 | 7293.25 | 31.20 | 1435.55 | 0.00 |
| SPLIT TN1 | 0.00 | 237870.94 | 237870.94 | 818502.78 | 7295.40 | 31.17 | 1433.43 | 0.00 |
| SPLIT TN2 | 0.00 | 237910.16 | 237910.16 | 818502.78 | 7294.98 | 31.34 | 1433.68 | 0.00 |
| SPLIT TS1 | 0.00 | 247338.00 | 247338.00 | 818502.78 | 7226.00 | 24.18 | 1509.83 | 804.67 |
| SPLIT TS2 | 0.00 | 247364.95 | 247364.95 | 818502.78 | 7225.83 | 24.31 | 1509.86 | 804.67 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0042 | 0.0042 | 0.0260 | 5689.17 | 28.08 | 427.75 |
| SPLIT GNW | 0.0000 | 0.0051 | 0.0051 | 0.0260 | 7997.08 | 59.00 | 703.92 |
| SPLIT OFFICE | 0.0514 | 0.0000 | 0.0514 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0051 | 0.0051 | 0.0260 | 7999.66 | 57.51 | 702.83 |
| SPLIT GN1 | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 7973.21 | 53.71 | 733.08 |
| SPLIT GN2 | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 7972.98 | 54.19 | 732.83 |
| SPLIT GS1 | 0.0000 | 0.0043 | 0.0043 | 0.0260 | 5682.17 | 25.67 | 437.17 |
| SPLIT GS2 | 0.0000 | 0.0043 | 0.0043 | 0.0260 | 5681.08 | 25.42 | 438.50 |
| SPLIT MSW | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 6133.83 | 1.67 | 9.50 |
| SPLIT MNW | 0.0000 | 0.0064 | 0.0064 | 0.0519 | 8728.00 | 5.33 | 26.67 |
| SPLIT MSE | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 6133.67 | 1.67 | 9.67 |
| SPLIT MNE | 0.0000 | 0.0064 | 0.0064 | 0.0519 | 8727.67 | 5.83 | 26.50 |
| SPLIT MN1 | 0.0000 | 0.0065 | 0.0065 | 0.0519 | 8727.00 | 5.83 | 27.17 |
| SPLIT MN2 | 0.0000 | 0.0065 | 0.0065 | 0.0519 | 8727.00 | 5.67 | 27.33 |
| SPLIT MS1 | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 6133.33 | 1.83 | 9.83 |
| SPLIT MS2 | 0.0000 | 0.0052 | 0.0052 | 0.0519 | 6133.33 | 1.83 | 9.83 |
| SPLIT TSW | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 5306.00 | 16.00 | 823.00 |
| SPLIT TNW | 0.0000 | 0.0075 | 0.0075 | 0.0260 | 7299.75 | 34.47 | 1425.78 |
| SPLIT TSE | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 5303.63 | 15.29 | 826.08 |
| SPLIT TNE | 0.0000 | 0.0075 | 0.0075 | 0.0260 | 7293.25 | 31.20 | 1435.55 |
| SPLIT TN1 | 0.0000 | 0.0075 | 0.0075 | 0.0260 | 7295.40 | 31.17 | 1433.43 |
| SPLIT TN2 | 0.0000 | 0.0075 | 0.0075 | 0.0260 | 7294.98 | 31.34 | 1433.68 |
| SPLIT TS1 | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 5303.17 | 15.08 | 826.75 |
| SPLIT TS2 | 0.0000 | 0.0060 | 0.0060 | 0.0260 | 5303.17 | 15.08 | 826.75 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 0.00 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0000 | 0.0514 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 106.23 | 1654.28 | 23-FEB-17:10 | 8828.93 | 01-AUG-17:00 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| ElectricityPurchased:Plant | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| Cogeneration:ElectricityPurchased | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| General:Cogeneration:ElectricityPurchased | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| ElectricityNet:Plant | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| Cogeneration:ElectricityNet | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| General:Cogeneration:ElectricityNet | 1303.81 | 16907.55 | 22-FEB-03:10 | 97401.70 | 29-AUG-17:10 |
| Electricity:HVAC | 276.16 | 1654.28 | 23-FEB-17:10 | 37688.69 | 01-AUG-17:00 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 106.23 | 1654.28 | 23-FEB-17:10 | 8828.93 | 01-AUG-17:00 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 169.93 | 0.00 | 01-JAN-00:10 | 28859.76 | 01-AUG-17:00 |
| General:Cooling:Electricity | 169.93 | 0.00 | 01-JAN-00:10 | 28859.76 | 01-AUG-17:00 |
| ExteriorLights:Electricity | 50.06 | 0.00 | 01-JAN-07:50 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 50.06 | 0.00 | 01-JAN-07:50 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 419.71 | 1950.00 | 01-JAN-00:10 | 37629.12 | 20-JAN-07:20 |
| WaterSystems:Electricity | 419.71 | 1950.00 | 01-JAN-00:10 | 37629.12 | 20-JAN-07:20 |
| Water Heater:WaterSystems:Electricity | 419.71 | 1950.00 | 01-JAN-00:10 | 37629.12 | 20-JAN-07:20 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 233.50 | 0.00 | 19-JAN-15:10 | 124189.29 | 12-FEB-06:00 |
| NaturalGas:HVAC | 233.50 | 0.00 | 19-JAN-15:10 | 124189.29 | 12-FEB-06:00 |
| Heating:NaturalGas | 233.50 | 0.00 | 19-JAN-15:10 | 124189.29 | 12-FEB-06:00 |
| General:Heating:NaturalGas | 233.50 | 0.00 | 19-JAN-15:10 | 124189.29 | 12-FEB-06:00 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 1493.65 | 1393.36 | 31-JAN-15:00 | 171701.48 | 12-FEB-06:00 |
| EnergyTransfer:Building | 639.60 | 1268.05 | 27-NOV-12:20 | 72350.05 | 12-FEB-06:00 |
| EnergyTransfer:Zone:G SW APARTMENT | 18.02 | 0.01 | 26-FEB-12:10 | 2200.85 | 18-AUG-17:20 |
| Heating:EnergyTransfer | 99.37 | 0.00 | 20-FEB-21:10 | 72350.05 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 2.27 | 0.00 | 01-JAN-10:50 | 2169.74 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer | 99.37 | 0.00 | 20-FEB-21:10 | 72350.05 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 2.27 | 0.00 | 01-JAN-10:50 | 2169.74 | 12-FEB-06:00 |
| Cooling:EnergyTransfer | 540.23 | 0.00 | 03-JAN-07:30 | 66504.18 | 01-AUG-17:00 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 15.75 | 0.00 | 01-JAN-00:10 | 2200.85 | 18-AUG-17:20 |
| General:Cooling:EnergyTransfer | 540.23 | 0.00 | 03-JAN-07:30 | 66504.18 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 15.75 | 0.00 | 01-JAN-00:10 | 2200.85 | 18-AUG-17:20 |
| EnergyTransfer:Zone:G NW APARTMENT | 17.05 | 0.00 | 10-APR-12:00 | 2294.08 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 3.98 | 0.00 | 01-JAN-12:00 | 2294.08 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 3.98 | 0.00 | 01-JAN-12:00 | 2294.08 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 13.06 | 0.00 | 01-JAN-00:10 | 2023.95 | 18-AUG-17:30 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 13.06 | 0.00 | 01-JAN-00:10 | 2023.95 | 18-AUG-17:30 |
| EnergyTransfer:Zone:OFFICE | 15.18 | 0.01 | 03-JUL-03:30 | 3711.31 | 17-JUL-08:10 |
| Heating:EnergyTransfer:Zone:OFFICE | 3.48 | 0.00 | 01-JAN-00:10 | 3556.98 | 09-JAN-09:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 3.48 | 0.00 | 01-JAN-00:10 | 3556.98 | 09-JAN-09:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 11.70 | 0.00 | 01-JAN-00:50 | 3711.31 | 17-JUL-08:10 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 11.70 | 0.00 | 01-JAN-00:50 | 3711.31 | 17-JUL-08:10 |
| EnergyTransfer:Zone:G NE APARTMENT | 17.11 | 0.02 | 30-APR-14:20 | 2308.39 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 3.92 | 0.00 | 01-JAN-11:30 | 2308.39 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 3.92 | 0.00 | 01-JAN-11:30 | 2308.39 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 13.19 | 0.00 | 01-JAN-00:10 | 1771.92 | 19-AUG-16:10 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 13.19 | 0.00 | 01-JAN-00:10 | 1771.92 | 19-AUG-16:10 |
| EnergyTransfer:Zone:G N1 APARTMENT | 13.94 | 0.05 | 07-APR-01:30 | 1387.09 | 19-AUG-16:10 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 1.55 | 0.00 | 01-JAN-03:20 | 1265.54 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 1.55 | 0.00 | 01-JAN-03:20 | 1265.54 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 12.38 | 0.00 | 01-JAN-00:10 | 1387.09 | 19-AUG-16:10 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 12.38 | 0.00 | 01-JAN-00:10 | 1387.09 | 19-AUG-16:10 |
| EnergyTransfer:Zone:G N2 APARTMENT | 13.95 | 0.01 | 18-DEC-12:40 | 1386.19 | 19-AUG-16:10 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 1.55 | 0.00 | 01-JAN-03:20 | 1266.50 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 1.55 | 0.00 | 01-JAN-03:20 | 1266.50 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 12.40 | 0.00 | 01-JAN-00:10 | 1386.19 | 19-AUG-16:10 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 12.40 | 0.00 | 01-JAN-00:10 | 1386.19 | 19-AUG-16:10 |
| EnergyTransfer:Zone:G S1 APARTMENT | 16.37 | 0.00 | 17-JAN-15:00 | 1631.19 | 10-OCT-16:10 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.58 | 0.00 | 01-JAN-01:00 | 1135.23 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.58 | 0.00 | 01-JAN-01:00 | 1135.23 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 15.78 | 0.00 | 01-JAN-00:10 | 1631.19 | 10-OCT-16:10 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 15.78 | 0.00 | 01-JAN-00:10 | 1631.19 | 10-OCT-16:10 |
| EnergyTransfer:Zone:G S2 APARTMENT | 17.68 | 0.01 | 18-JAN-11:10 | 1733.26 | 19-AUG-16:10 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.76 | 0.00 | 01-JAN-05:20 | 1261.01 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.76 | 0.00 | 01-JAN-05:20 | 1261.01 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 16.92 | 0.00 | 01-JAN-00:10 | 1733.26 | 19-AUG-16:10 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 16.92 | 0.00 | 01-JAN-00:10 | 1733.26 | 19-AUG-16:10 |
| EnergyTransfer:Zone:M SW APARTMENT | 44.83 | 0.06 | 01-JAN-07:00 | 5082.27 | 18-AUG-17:20 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 4.04 | 0.00 | 01-JAN-06:10 | 4840.98 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 4.04 | 0.00 | 01-JAN-06:10 | 4840.98 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 40.80 | 0.00 | 01-JAN-00:10 | 5082.27 | 18-AUG-17:20 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 40.80 | 0.00 | 01-JAN-00:10 | 5082.27 | 18-AUG-17:20 |
| EnergyTransfer:Zone:M NW APARTMENT | 40.91 | 0.19 | 15-FEB-13:20 | 5118.87 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 6.90 | 0.00 | 01-JAN-07:10 | 5118.87 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 6.90 | 0.00 | 01-JAN-07:10 | 5118.87 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 34.00 | 0.00 | 01-JAN-00:10 | 4860.86 | 06-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 34.00 | 0.00 | 01-JAN-00:10 | 4860.86 | 06-JUN-17:30 |
| EnergyTransfer:Zone:M SE APARTMENT | 45.01 | 0.15 | 27-JAN-11:30 | 4871.92 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 3.96 | 0.00 | 01-JAN-06:10 | 4871.92 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 3.96 | 0.00 | 01-JAN-06:10 | 4871.92 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 41.04 | 0.00 | 01-JAN-00:10 | 4552.39 | 19-AUG-14:00 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 41.04 | 0.00 | 01-JAN-00:10 | 4552.39 | 19-AUG-14:00 |
| EnergyTransfer:Zone:M NE APARTMENT | 41.02 | 0.10 | 16-DEC-10:40 | 5154.33 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 6.78 | 0.00 | 01-JAN-07:10 | 5154.33 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 6.78 | 0.00 | 01-JAN-07:10 | 5154.33 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 34.24 | 0.00 | 01-JAN-00:10 | 4228.89 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 34.24 | 0.00 | 01-JAN-00:10 | 4228.89 | 01-AUG-17:00 |
| EnergyTransfer:Zone:M N1 APARTMENT | 33.14 | 0.08 | 07-FEB-16:00 | 3160.68 | 06-JUN-17:30 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 2.08 | 0.00 | 01-JAN-00:20 | 2629.90 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 2.08 | 0.00 | 01-JAN-00:20 | 2629.90 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 31.06 | 0.00 | 01-JAN-00:10 | 3160.68 | 06-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 31.06 | 0.00 | 01-JAN-00:10 | 3160.68 | 06-JUN-17:30 |
| EnergyTransfer:Zone:M N2 APARTMENT | 33.16 | 0.31 | 23-DEC-03:40 | 3153.64 | 06-JUN-17:30 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 2.08 | 0.00 | 01-JAN-00:20 | 2632.68 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 2.08 | 0.00 | 01-JAN-00:20 | 2632.68 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 31.08 | 0.00 | 01-JAN-00:10 | 3153.64 | 06-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 31.08 | 0.00 | 01-JAN-00:10 | 3153.64 | 06-JUN-17:30 |
| EnergyTransfer:Zone:M S1 APARTMENT | 39.91 | 0.01 | 08-FEB-00:20 | 3638.71 | 10-OCT-15:10 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.75 | 0.00 | 01-JAN-00:10 | 2433.47 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.75 | 0.00 | 01-JAN-00:10 | 2433.47 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 39.16 | 0.00 | 02-JAN-01:20 | 3638.71 | 10-OCT-15:10 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 39.16 | 0.00 | 02-JAN-01:20 | 3638.71 | 10-OCT-15:10 |
| EnergyTransfer:Zone:M S2 APARTMENT | 39.95 | 0.13 | 07-FEB-02:30 | 3643.87 | 10-OCT-14:10 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.75 | 0.00 | 01-JAN-00:10 | 2435.37 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.75 | 0.00 | 01-JAN-00:10 | 2435.37 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 39.20 | 0.00 | 02-JAN-01:20 | 3643.87 | 10-OCT-14:10 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 39.20 | 0.00 | 02-JAN-01:20 | 3643.87 | 10-OCT-14:10 |
| EnergyTransfer:Zone:T SW APARTMENT | 27.67 | 0.11 | 24-FEB-23:20 | 4499.17 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 7.70 | 0.00 | 01-JAN-12:00 | 4499.17 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 7.70 | 0.00 | 01-JAN-12:00 | 4499.17 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 19.97 | 0.00 | 01-JAN-00:10 | 3607.69 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 19.97 | 0.00 | 01-JAN-00:10 | 3607.69 | 01-AUG-17:00 |
| EnergyTransfer:Zone:T NW APARTMENT | 27.04 | 0.03 | 24-FEB-21:00 | 4577.81 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 10.10 | 0.00 | 01-JAN-12:30 | 4577.81 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 10.10 | 0.00 | 01-JAN-12:30 | 4577.81 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 16.94 | 0.00 | 01-JAN-00:10 | 3460.55 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 16.94 | 0.00 | 01-JAN-00:10 | 3460.55 | 01-AUG-17:00 |
| EnergyTransfer:Zone:T SE APARTMENT | 27.54 | 0.03 | 16-MAR-12:30 | 4500.83 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 7.57 | 0.00 | 01-JAN-11:40 | 4500.83 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 7.57 | 0.00 | 01-JAN-11:40 | 4500.83 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 19.97 | 0.00 | 01-JAN-00:10 | 3225.56 | 19-AUG-14:00 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 19.97 | 0.00 | 01-JAN-00:10 | 3225.56 | 19-AUG-14:00 |
| EnergyTransfer:Zone:T NE APARTMENT | 26.88 | 0.16 | 06-APR-20:50 | 4577.76 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 9.91 | 0.00 | 01-JAN-12:30 | 4577.76 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 9.91 | 0.00 | 01-JAN-12:30 | 4577.76 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 16.97 | 0.00 | 01-JAN-00:10 | 2968.55 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 16.97 | 0.00 | 01-JAN-00:10 | 2968.55 | 01-AUG-17:00 |
| EnergyTransfer:Zone:T N1 APARTMENT | 20.08 | 0.07 | 28-DEC-15:50 | 2963.28 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 5.61 | 0.00 | 01-JAN-10:50 | 2963.28 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 5.61 | 0.00 | 01-JAN-10:50 | 2963.28 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 14.46 | 0.00 | 01-JAN-00:10 | 2326.40 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 14.46 | 0.00 | 01-JAN-00:10 | 2326.40 | 01-AUG-17:00 |
| EnergyTransfer:Zone:T N2 APARTMENT | 20.09 | 0.02 | 30-JAN-15:20 | 2964.14 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 5.61 | 0.00 | 01-JAN-10:50 | 2964.14 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 5.61 | 0.00 | 01-JAN-10:50 | 2964.14 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 14.48 | 0.00 | 01-JAN-00:10 | 2318.03 | 01-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 14.48 | 0.00 | 01-JAN-00:10 | 2318.03 | 01-AUG-17:00 |
| EnergyTransfer:Zone:T S1 APARTMENT | 21.53 | 0.00 | 30-DEC-12:40 | 2879.35 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 3.71 | 0.00 | 01-JAN-09:50 | 2879.35 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 3.71 | 0.00 | 01-JAN-09:50 | 2879.35 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 17.82 | 0.00 | 01-JAN-00:10 | 2515.19 | 19-AUG-14:00 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 17.82 | 0.00 | 01-JAN-00:10 | 2515.19 | 19-AUG-14:00 |
| EnergyTransfer:Zone:T S2 APARTMENT | 21.55 | 0.02 | 24-JAN-22:00 | 2880.47 | 12-FEB-06:00 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 3.71 | 0.00 | 01-JAN-09:40 | 2880.47 | 12-FEB-06:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 3.71 | 0.00 | 01-JAN-09:40 | 2880.47 | 12-FEB-06:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 17.84 | 0.00 | 01-JAN-00:10 | 2521.51 | 19-AUG-14:00 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 17.84 | 0.00 | 01-JAN-00:10 | 2521.51 | 19-AUG-14:00 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 854.06 | 0.00 | 19-JAN-15:50 | 102522.40 | 01-AUG-17:00 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 21-JUL-20:40 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 31-MAY-14:00 |
| HeatingCoils:EnergyTransfer | 186.80 | 0.00 | 19-JAN-15:10 | 99351.43 | 12-FEB-06:00 |
| CoolingCoils:EnergyTransfer | 667.26 | 0.00 | 01-JAN-00:10 | 102522.40 | 01-AUG-17:00 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 1.022 | -6.451 | 5.419 | -13.472 | 0.000 | 0.000 | 3.788 | 1.454 | 12.213 | 8.874 | 0.000 | 0.392 | 0.000 | 0.000 | -4.906 | 0.000 | -4.745 | -3.588 |
| G NW APARTMENT | 1.028 | -6.262 | 7.893 | -11.740 | 0.000 | 0.000 | 3.874 | 1.454 | 12.213 | 5.253 | 0.000 | 0.397 | 0.000 | 0.000 | -5.099 | 0.000 | -4.545 | -4.465 |
| OFFICE | 0.000 | 0.000 | 3.480 | -11.698 | 0.000 | 0.000 | 2.067 | 7.396 | 9.469 | 8.522 | 0.000 | 0.222 | 0.000 | 0.000 | -5.100 | 0.000 | -4.116 | -10.240 |
| G NE APARTMENT | 1.028 | -6.260 | 7.820 | -11.862 | 0.000 | 0.000 | 3.876 | 1.454 | 12.213 | 5.093 | 0.000 | 0.397 | 0.000 | 0.000 | -4.860 | 0.000 | -4.545 | -4.355 |
| G N1 APARTMENT | 1.028 | -6.354 | 4.901 | -10.406 | 0.000 | 0.000 | 3.854 | 1.454 | 12.213 | 2.054 | 0.000 | 0.239 | 0.000 | 0.000 | -3.249 | 0.000 | -3.080 | -2.654 |
| G N2 APARTMENT | 1.028 | -6.354 | 4.902 | -10.418 | 0.000 | 0.000 | 3.854 | 1.454 | 12.213 | 2.054 | 0.000 | 0.239 | 0.000 | 0.000 | -3.249 | 0.000 | -3.080 | -2.644 |
| G S1 APARTMENT | 1.021 | -6.608 | 2.799 | -12.415 | 0.000 | 0.000 | 3.756 | 1.454 | 12.213 | 5.733 | 0.000 | 0.236 | 0.000 | 0.000 | -3.021 | 0.000 | -3.275 | -1.894 |
| G S2 APARTMENT | 1.021 | -6.619 | 3.071 | -13.627 | 0.000 | 0.000 | 3.753 | 1.454 | 12.213 | 5.721 | 0.000 | 0.236 | 0.000 | 0.000 | -3.031 | 0.000 | -3.284 | -0.909 |
| M SW APARTMENT | 2.042 | -13.223 | 9.357 | -34.938 | 0.000 | 0.000 | 7.506 | 2.908 | 24.426 | 17.390 | 0.000 | 1.121 | 7.331 | 0.000 | -10.259 | 0.000 | -13.661 | -0.000 |
| M NW APARTMENT | 2.043 | -12.818 | 14.011 | -30.339 | 0.000 | 0.000 | 7.678 | 2.908 | 24.426 | 10.219 | 0.000 | 1.122 | 4.583 | 0.000 | -10.705 | 0.000 | -13.128 | -0.000 |
| M SE APARTMENT | 2.041 | -13.238 | 9.270 | -35.155 | 0.000 | 0.000 | 7.508 | 2.908 | 24.426 | 17.289 | 0.000 | 1.121 | 7.516 | 0.000 | -10.001 | 0.000 | -13.685 | -0.001 |
| M NE APARTMENT | 2.043 | -12.826 | 13.866 | -30.545 | 0.000 | 0.000 | 7.682 | 2.908 | 24.426 | 9.884 | 0.000 | 1.122 | 4.795 | 0.000 | -10.211 | 0.000 | -13.144 | -0.000 |
| M N1 APARTMENT | 2.044 | -13.038 | 7.763 | -25.751 | 0.000 | 0.000 | 7.631 | 2.908 | 24.426 | 3.987 | 0.000 | 0.677 | 4.981 | 0.000 | -6.815 | 0.000 | -8.813 | -0.000 |
| M N2 APARTMENT | 2.044 | -13.038 | 7.764 | -25.775 | 0.000 | 0.000 | 7.631 | 2.908 | 24.426 | 3.986 | 0.000 | 0.677 | 5.007 | 0.000 | -6.814 | 0.000 | -8.814 | -0.000 |
| M S1 APARTMENT | 2.042 | -13.567 | 4.088 | -30.976 | 0.000 | 0.000 | 7.434 | 2.908 | 24.426 | 11.275 | 0.000 | 0.676 | 7.284 | 0.000 | -6.298 | 0.000 | -9.291 | -0.000 |
| M S2 APARTMENT | 2.042 | -13.568 | 4.090 | -31.007 | 0.000 | 0.000 | 7.434 | 2.908 | 24.426 | 11.274 | 0.000 | 0.676 | 7.316 | 0.000 | -6.298 | 0.000 | -9.292 | -0.000 |
| T SW APARTMENT | 1.021 | -6.318 | 11.785 | -18.753 | 0.000 | 0.000 | 3.820 | 1.454 | 12.213 | 8.645 | 0.000 | 0.734 | 0.000 | 0.000 | -4.771 | 0.000 | -8.514 | -1.318 |
| T NW APARTMENT | 1.021 | -6.179 | 14.692 | -16.371 | 0.000 | 0.000 | 3.890 | 1.454 | 12.213 | 5.071 | 0.000 | 0.734 | 0.000 | 0.000 | -5.021 | 0.000 | -8.240 | -3.264 |
| T SE APARTMENT | 1.020 | -6.328 | 11.628 | -18.724 | 0.000 | 0.000 | 3.823 | 1.454 | 12.213 | 8.604 | 0.000 | 0.734 | 0.001 | 0.000 | -4.654 | 0.000 | -8.546 | -1.224 |
| T NE APARTMENT | 1.021 | -6.180 | 14.495 | -16.391 | 0.000 | 0.000 | 3.894 | 1.454 | 12.213 | 4.926 | 0.000 | 0.734 | 0.000 | 0.000 | -4.795 | 0.000 | -8.252 | -3.119 |
| T N1 APARTMENT | 1.021 | -6.233 | 9.925 | -13.563 | 0.000 | 0.000 | 3.877 | 1.454 | 12.213 | 1.988 | 0.000 | 0.443 | 0.000 | 0.000 | -3.191 | 0.000 | -5.398 | -2.535 |
| T N2 APARTMENT | 1.021 | -6.233 | 9.927 | -13.580 | 0.000 | 0.000 | 3.877 | 1.454 | 12.213 | 1.986 | 0.000 | 0.443 | 0.000 | 0.000 | -3.190 | 0.000 | -5.399 | -2.520 |
| T S1 APARTMENT | 1.021 | -6.423 | 7.227 | -15.935 | 0.000 | 0.000 | 3.797 | 1.454 | 12.213 | 5.633 | 0.000 | 0.443 | 0.000 | 0.000 | -2.925 | 0.000 | -5.671 | -0.834 |
| T S2 APARTMENT | 1.021 | -6.424 | 7.231 | -15.960 | 0.000 | 0.000 | 3.798 | 1.454 | 12.213 | 5.631 | 0.000 | 0.443 | 0.000 | 0.000 | -2.924 | 0.000 | -5.672 | -0.811 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.095 | 11.688 | 0.000 | 0.726 | 0.000 | 0.061 | 0.000 | 0.000 | -0.508 | 0.000 | -1.333 | -16.730 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.128 | 11.688 | 3.530 | 2.179 | 0.000 | 1.416 | 0.000 | 0.000 | -1.465 | 0.000 | -18.010 | -5.466 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 11.582 | 23.376 | 0.000 | 1.421 | 0.000 | 0.108 | 0.000 | 0.000 | -1.116 | 0.000 | -2.268 | -33.102 |
| Total Facility | 31.685 | -200.541 | 197.403 | -469.401 | 0.000 | 0.000 | 143.905 | 99.229 | 391.594 | 175.419 | 0.000 | 15.840 | 48.816 | 0.000 | -134.475 | 0.000 | -197.799 | -101.673 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 18-AUG-17:17 | 0.00 | 335.28 | 0.00 | -2536.42 | 0.00 | 0.00 | 167.23 | 117.18 | 588.62 | 1111.92 | 0.00 | 157.89 | 58.29 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 18-AUG-17:30 | 0.00 | 332.81 | 0.00 | -2356.95 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1074.46 | 0.00 | 159.72 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -61.34 |
| OFFICE | 12-OCT-08:62 | 0.00 | 0.00 | 0.00 | -6057.73 | 0.00 | 0.00 | 284.66 | 582.92 | 588.62 | 842.90 | 0.00 | 0.00 | 3983.02 | 0.00 | -0.00 | 0.00 | -224.38 | 0.00 |
| G NE APARTMENT | 19-AUG-16:05 | 0.00 | 277.17 | 0.00 | -2049.31 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 568.49 | 0.00 | 146.87 | 294.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 19-AUG-16:05 | 0.00 | 277.23 | 0.00 | -1664.52 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 347.42 | 0.00 | 88.59 | 188.90 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 19-AUG-16:05 | 0.00 | 277.23 | 0.00 | -1663.62 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 347.43 | 0.00 | 88.59 | 187.99 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 10-OCT-16:03 | 0.00 | 199.08 | 0.00 | -1830.47 | 0.00 | 0.00 | 0.00 | 86.80 | 588.62 | 602.65 | 0.00 | 45.25 | 308.06 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 19-AUG-16:05 | 0.00 | 277.11 | 0.00 | -2010.58 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 403.10 | 0.00 | 88.59 | 399.13 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 18-AUG-17:17 | 0.00 | 670.54 | 0.00 | -5753.27 | 0.00 | 0.00 | 334.45 | 234.36 | 1177.25 | 2223.73 | 0.00 | 452.93 | 660.00 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 06-JUN-17:25 | 0.00 | 616.32 | 0.00 | -5477.74 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 2374.65 | 0.00 | 764.14 | 20.04 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 19-AUG-14:00 | 0.00 | 650.77 | 0.00 | -5203.40 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 2119.07 | 0.00 | 534.25 | 932.16 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 01-AUG-17:00 | 0.00 | 718.60 | 0.00 | -4947.74 | 0.00 | 0.00 | 173.92 | 173.60 | 1177.25 | 1109.70 | 0.00 | 708.11 | 886.57 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 06-JUN-17:25 | 0.00 | 616.50 | 0.00 | -3777.44 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 749.03 | 0.00 | 460.91 | 248.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 06-JUN-17:25 | 0.00 | 616.50 | 0.00 | -3770.43 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 749.09 | 0.00 | 460.91 | 241.34 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 10-OCT-15:10 | 0.00 | 353.00 | 0.00 | -3991.58 | 0.00 | 0.00 | 0.00 | 121.52 | 941.80 | 1797.69 | 0.00 | 102.75 | 674.83 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 10-OCT-14:10 | 0.00 | 367.42 | 0.00 | -4011.22 | 0.00 | 0.00 | 0.00 | 60.77 | 800.53 | 2317.76 | 0.00 | 118.76 | 345.99 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 01-AUG-17:00 | 0.00 | 358.96 | 0.00 | -3966.93 | 0.00 | 0.00 | 0.00 | 86.80 | 588.62 | 1140.19 | 0.00 | 466.65 | 1325.71 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 01-AUG-17:00 | 0.00 | 359.04 | 0.00 | -3819.83 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 1148.98 | 0.00 | 466.65 | 1082.78 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 19-AUG-14:00 | 0.00 | 325.23 | 0.00 | -3551.00 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1032.64 | 0.00 | 351.93 | 1357.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 01-AUG-17:00 | 0.00 | 359.14 | 0.00 | -3327.95 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 533.54 | 0.00 | 466.65 | 1206.24 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 01-AUG-17:00 | 0.00 | 359.14 | 0.00 | -2685.65 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 329.16 | 0.00 | 281.47 | 953.51 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 01-AUG-17:00 | 0.00 | 359.14 | 0.00 | -2677.29 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 329.26 | 0.00 | 281.47 | 945.04 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 19-AUG-14:00 | 0.00 | 325.25 | 0.00 | -2840.51 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 745.97 | 0.00 | 212.27 | 1073.44 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 19-AUG-14:00 | 0.00 | 325.24 | 0.00 | -2846.83 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 745.89 | 0.00 | 212.27 | 1079.85 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 01-AUG-17:00 | 0.00 | 11135.65 | 0.00 | -77643.27 | 0.00 | 0.00 | 1817.14 | 4289.87 | 18750.02 | 19261.88 | 0.00 | 11787.86 | 10600.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 12-FEB-06:00 | -990.24 | 0.00 | 3159.96 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -907.79 | 0.00 | -1184.64 | -581.81 |
| G NW APARTMENT | 12-FEB-06:00 | -990.24 | 0.00 | 3284.31 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -924.26 | 0.00 | -1184.64 | -689.68 |
| OFFICE | 17-JAN-07:01 | 0.00 | 0.00 | 8783.68 | 0.00 | 0.00 | 0.00 | 0.00 | 116.58 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -399.88 | 0.00 | -372.49 | -8422.21 |
| G NE APARTMENT | 12-FEB-06:00 | -990.24 | 0.00 | 3298.62 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -910.45 | 0.00 | -1184.64 | -717.81 |
| G N1 APARTMENT | 12-FEB-06:00 | -990.38 | 0.00 | 2255.92 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -564.73 | 0.00 | -714.54 | -490.78 |
| G N2 APARTMENT | 12-FEB-06:00 | -990.38 | 0.00 | 2256.88 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -564.71 | 0.00 | -714.54 | -491.76 |
| G S1 APARTMENT | 12-FEB-06:00 | -990.39 | 0.00 | 2125.61 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -547.17 | 0.00 | -714.54 | -378.02 |
| G S2 APARTMENT | 12-FEB-06:00 | -990.39 | 0.00 | 2251.38 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -545.16 | 0.00 | -714.54 | -505.81 |
| M SW APARTMENT | 12-FEB-06:00 | -1980.26 | 0.00 | 6821.22 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1858.31 | 0.00 | -3406.88 | -584.80 |
| M NW APARTMENT | 12-FEB-06:00 | -1980.27 | 0.00 | 7099.10 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1895.93 | 0.00 | -3406.88 | -825.06 |
| M SE APARTMENT | 12-FEB-06:00 | -1980.26 | 0.00 | 6852.16 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1827.11 | 0.00 | -3406.88 | -646.93 |
| M NE APARTMENT | 12-FEB-06:00 | -1980.27 | 0.00 | 7134.56 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1864.81 | 0.00 | -3406.88 | -891.63 |
| M N1 APARTMENT | 12-FEB-06:00 | -1980.55 | 0.00 | 4610.43 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1157.03 | 0.00 | -2054.95 | -426.94 |
| M N2 APARTMENT | 12-FEB-06:00 | -1980.55 | 0.00 | 4613.22 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1156.97 | 0.00 | -2054.95 | -429.78 |
| M S1 APARTMENT | 12-FEB-06:00 | -1980.55 | 0.00 | 4414.00 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1116.59 | 0.00 | -2054.95 | -270.95 |
| M S2 APARTMENT | 12-FEB-06:00 | -1980.55 | 0.00 | 4415.91 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 506.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1116.54 | 0.00 | -2054.95 | -272.90 |
| T SW APARTMENT | 12-FEB-06:00 | -990.06 | 0.00 | 5489.21 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -899.73 | 0.00 | -2256.01 | -1847.92 |
| T NW APARTMENT | 12-FEB-06:00 | -990.06 | 0.00 | 5567.85 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -921.19 | 0.00 | -2256.01 | -1905.09 |
| T SE APARTMENT | 12-FEB-06:00 | -990.06 | 0.00 | 5490.87 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -883.97 | 0.00 | -2256.01 | -1865.34 |
| T NE APARTMENT | 12-FEB-06:00 | -990.06 | 0.00 | 5567.80 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -905.51 | 0.00 | -2256.01 | -1920.73 |
| T N1 APARTMENT | 12-FEB-06:00 | -990.20 | 0.00 | 3953.46 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -563.41 | 0.00 | -1360.77 | -1543.59 |
| T N2 APARTMENT | 12-FEB-06:00 | -990.20 | 0.00 | 3954.32 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -563.40 | 0.00 | -1360.77 | -1544.47 |
| T S1 APARTMENT | 12-FEB-06:00 | -990.20 | 0.00 | 3869.54 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -541.06 | 0.00 | -1360.77 | -1482.02 |
| T S2 APARTMENT | 12-FEB-06:00 | -990.20 | 0.00 | 3870.66 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -541.04 | 0.00 | -1360.77 | -1483.16 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 12-FEB-06:00 | -30696.59 | 0.00 | 103046.22 | 0.00 | 0.00 | 0.00 | 7433.60 | 3348.00 | 8128.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -24073.33 | 0.00 | -44848.58 | -22338.14 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3476 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3476 | 0.0747 | 1.0000 | Not calculated | 0.0260 | 0.0747 | ||
| SPLIT GNW | 0.3391 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3391 | 0.0765 | 1.0000 | Not calculated | 0.0260 | 0.0765 | ||
| SPLIT OFFICE | 0.3695 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3695 | 0.1031 | 1.0000 | Not calculated | 0.0381 | 0.1031 | ||
| SPLIT GNE | 0.3136 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3136 | 0.0828 | 1.0000 | Not calculated | 0.0260 | 0.0828 | ||
| SPLIT GN1 | 0.2839 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2839 | 0.0914 | 1.0000 | Not calculated | 0.0260 | 0.0914 | ||
| SPLIT GN2 | 0.2835 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2835 | 0.0915 | 1.0000 | Not calculated | 0.0260 | 0.0915 | ||
| SPLIT GS1 | 0.2955 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2955 | 0.0878 | 1.0000 | Not calculated | 0.0260 | 0.0878 | ||
| SPLIT GS2 | 0.2979 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2979 | 0.0871 | 1.0000 | Not calculated | 0.0260 | 0.0871 | ||
| SPLIT MSW | 0.8440 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8440 | 0.0615 | 1.0000 | Not calculated | 0.0519 | 0.0615 | ||
| SPLIT MNW | 0.8284 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8284 | 0.0627 | 1.0000 | Not calculated | 0.0519 | 0.0627 | ||
| SPLIT MSE | 0.7743 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7743 | 0.0670 | 1.0000 | Not calculated | 0.0519 | 0.0670 | ||
| SPLIT MNE | 0.7589 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7589 | 0.0684 | 1.0000 | Not calculated | 0.0519 | 0.0684 | ||
| SPLIT MN1 | 0.6793 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6793 | 0.0764 | 1.0000 | Not calculated | 0.0519 | 0.0764 | ||
| SPLIT MN2 | 0.6783 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6783 | 0.0765 | 1.0000 | Not calculated | 0.0519 | 0.0765 | ||
| SPLIT MS1 | 0.6973 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6973 | 0.0744 | 1.0000 | Not calculated | 0.0519 | 0.0744 | ||
| SPLIT MS2 | 0.6963 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6963 | 0.0745 | 1.0000 | Not calculated | 0.0519 | 0.0745 | ||
| SPLIT TSW | 0.4785 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4785 | 0.0542 | 1.0000 | Not calculated | 0.0260 | 0.0542 | ||
| SPLIT TNW | 0.4740 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4740 | 0.0548 | 1.0000 | Not calculated | 0.0260 | 0.0548 | ||
| SPLIT TSE | 0.4262 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4262 | 0.0609 | 1.0000 | Not calculated | 0.0260 | 0.0609 | ||
| SPLIT TNE | 0.4216 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4216 | 0.0616 | 1.0000 | Not calculated | 0.0260 | 0.0616 | ||
| SPLIT TN1 | 0.3884 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3884 | 0.0668 | 1.0000 | Not calculated | 0.0260 | 0.0668 | ||
| SPLIT TN2 | 0.3870 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3870 | 0.0671 | 1.0000 | Not calculated | 0.0260 | 0.0671 | ||
| SPLIT TS1 | 0.3937 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3937 | 0.0659 | 1.0000 | Not calculated | 0.0260 | 0.0659 | ||
| SPLIT TS2 | 0.3922 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3922 | 0.0662 | 1.0000 | Not calculated | 0.0260 | 0.0662 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3476 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3476 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0747 | ||
| SPLIT GNW | 0.3391 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3391 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0765 | ||
| SPLIT OFFICE | 0.3695 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3695 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.1031 | ||
| SPLIT GNE | 0.3136 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3136 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0828 | ||
| SPLIT GN1 | 0.2839 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2839 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0914 | ||
| SPLIT GN2 | 0.2835 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2835 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0915 | ||
| SPLIT GS1 | 0.2955 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2955 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0878 | ||
| SPLIT GS2 | 0.2979 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2979 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0871 | ||
| SPLIT MSW | 0.8440 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8440 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0615 | ||
| SPLIT MNW | 0.8284 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8284 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0627 | ||
| SPLIT MSE | 0.7743 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7743 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0670 | ||
| SPLIT MNE | 0.7589 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7589 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0684 | ||
| SPLIT MN1 | 0.6793 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6793 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0764 | ||
| SPLIT MN2 | 0.6783 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6783 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0765 | ||
| SPLIT MS1 | 0.6973 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6973 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0744 | ||
| SPLIT MS2 | 0.6963 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6963 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0745 | ||
| SPLIT TSW | 0.4785 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4785 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0542 | ||
| SPLIT TNW | 0.4740 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4740 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0548 | ||
| SPLIT TSE | 0.4262 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4262 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0609 | ||
| SPLIT TNE | 0.4216 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4216 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0616 | ||
| SPLIT TN1 | 0.3884 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3884 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0668 | ||
| SPLIT TN2 | 0.3870 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3870 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0671 | ||
| SPLIT TS1 | 0.3937 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3937 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0659 | ||
| SPLIT TS2 | 0.3922 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3922 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0662 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3476 | 0.3476 | 0.3476 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3391 | 0.3391 | 0.3391 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3695 | 0.3695 | 0.3695 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3136 | 0.3136 | 0.3136 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2839 | 0.2839 | 0.2839 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2835 | 0.2835 | 0.2835 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2955 | 0.2955 | 0.2955 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2979 | 0.2979 | 0.2979 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8440 | 0.8440 | 0.8440 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8284 | 0.8284 | 0.8284 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7743 | 0.7743 | 0.7743 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7589 | 0.7589 | 0.7589 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6793 | 0.6793 | 0.6793 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6783 | 0.6783 | 0.6783 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6973 | 0.6973 | 0.6973 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6963 | 0.6963 | 0.6963 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4785 | 0.4785 | 0.4785 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4740 | 0.4740 | 0.4740 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4262 | 0.4262 | 0.4262 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4216 | 0.4216 | 0.4216 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3884 | 0.3884 | 0.3884 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3870 | 0.3870 | 0.3870 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3937 | 0.3937 | 0.3937 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3922 | 0.3922 | 0.3922 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3476 | 0.3476 | 0.3476 | 0.3476 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3391 | 0.3391 | 0.3391 | 0.3391 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3695 | 0.3695 | 0.3695 | 0.3695 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3136 | 0.3136 | 0.3136 | 0.3136 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2839 | 0.2839 | 0.2839 | 0.2839 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2835 | 0.2835 | 0.2835 | 0.2835 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2955 | 0.2955 | 0.2955 | 0.2955 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2979 | 0.2979 | 0.2979 | 0.2979 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.8440 | 0.8440 | 0.8440 | 0.8440 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8284 | 0.8284 | 0.8284 | 0.8284 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7743 | 0.7743 | 0.7743 | 0.7743 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7589 | 0.7589 | 0.7589 | 0.7589 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6793 | 0.6793 | 0.6793 | 0.6793 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6783 | 0.6783 | 0.6783 | 0.6783 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6973 | 0.6973 | 0.6973 | 0.6973 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6963 | 0.6963 | 0.6963 | 0.6963 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4785 | 0.4785 | 0.4785 | 0.4785 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4740 | 0.4740 | 0.4740 | 0.4740 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4262 | 0.4262 | 0.4262 | 0.4262 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4216 | 0.4216 | 0.4216 | 0.4216 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3884 | 0.3884 | 0.3884 | 0.3884 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3870 | 0.3870 | 0.3870 | 0.3870 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3937 | 0.3937 | 0.3937 | 0.3937 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3922 | 0.3922 | 0.3922 | 0.3922 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3476 | 0.3476 | 0.3476 | No | 0.0260 | 0.2339 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3391 | 0.3391 | 0.3391 | No | 0.0260 | 0.2468 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3695 | 0.3695 | 0.3695 | No | 0.0381 | 0.2837 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3136 | 0.3136 | 0.3136 | No | 0.0260 | 0.2477 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2839 | 0.2839 | 0.2839 | No | 0.0260 | 0.4153 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2835 | 0.2835 | 0.2835 | No | 0.0260 | 0.4154 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2955 | 0.2955 | 0.2955 | No | 0.0260 | 0.3795 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2979 | 0.2979 | 0.2979 | No | 0.0260 | 0.3771 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8440 | 0.8440 | 0.8440 | No | 0.0519 | 0.2334 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8284 | 0.8284 | 0.8284 | No | 0.0519 | 0.2491 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7743 | 0.7743 | 0.7743 | No | 0.0519 | 0.2344 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7589 | 0.7589 | 0.7589 | No | 0.0519 | 0.2502 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6793 | 0.6793 | 0.6793 | No | 0.0519 | 0.4645 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6783 | 0.6783 | 0.6783 | No | 0.0519 | 0.4646 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6973 | 0.6973 | 0.6973 | No | 0.0519 | 0.4139 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6963 | 0.6963 | 0.6963 | No | 0.0519 | 0.4140 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4785 | 0.4785 | 0.4785 | No | 0.0260 | 0.1406 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4740 | 0.4740 | 0.4740 | No | 0.0260 | 0.1464 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4262 | 0.4262 | 0.4262 | No | 0.0260 | 0.1411 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4216 | 0.4216 | 0.4216 | No | 0.0260 | 0.1469 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3884 | 0.3884 | 0.3884 | No | 0.0260 | 0.2182 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3870 | 0.3870 | 0.3870 | No | 0.0260 | 0.2182 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3937 | 0.3937 | 0.3937 | No | 0.0260 | 0.2055 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3922 | 0.3922 | 0.3922 | No | 0.0260 | 0.2055 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3476 | 0.3476 | 0.3476 | 0.3476 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3391 | 0.3391 | 0.3391 | 0.3391 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3695 | 0.3695 | 0.3695 | 0.3695 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3136 | 0.3136 | 0.3136 | 0.3136 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2839 | 0.2839 | 0.2839 | 0.2839 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2835 | 0.2835 | 0.2835 | 0.2835 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2955 | 0.2955 | 0.2955 | 0.2955 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2979 | 0.2979 | 0.2979 | 0.2979 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.8440 | 0.8440 | 0.8440 | 0.8440 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8284 | 0.8284 | 0.8284 | 0.8284 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7743 | 0.7743 | 0.7743 | 0.7743 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7589 | 0.7589 | 0.7589 | 0.7589 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6793 | 0.6793 | 0.6793 | 0.6793 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6783 | 0.6783 | 0.6783 | 0.6783 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6973 | 0.6973 | 0.6973 | 0.6973 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6963 | 0.6963 | 0.6963 | 0.6963 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4785 | 0.4785 | 0.4785 | 0.4785 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4740 | 0.4740 | 0.4740 | 0.4740 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4262 | 0.4262 | 0.4262 | 0.4262 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4216 | 0.4216 | 0.4216 | 0.4216 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3884 | 0.3884 | 0.3884 | 0.3884 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3870 | 0.3870 | 0.3870 | 0.3870 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3937 | 0.3937 | 0.3937 | 0.3937 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3922 | 0.3922 | 0.3922 | 0.3922 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 233.50 | 124189.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 169.93 | 28859.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 50.06 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 106.23 | 8828.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 419.71 | 37629.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1303.81 |
| Natural Gas | 0.00 | 233.50 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1537.31 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 54.21 |
| Fans (All) | 33.89 |
| Service Water Heating | 133.89 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 415.94 |
| Subtotal | 415.94 |
| Natural Gas [MJ/m2] | |
| Space Heating | 74.49 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 74.49 |
| Subtotal | 74.49 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 6.45 |
| Space Heating | 15.19 |
| Space Cooling | 11.05 |
| Fans (All) | 6.91 |
| Service Water Heating | 27.30 |
| Receptacle Equipment | 29.84 |
| Miscellaneous | 3.26 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6644.83 | 2085.50 | 29.67 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 6275.17 | 2395.50 | 89.33 | 0.00 | 0.00 |
| G CORRIDOR | 6630.67 | 2119.33 | 10.00 | 0.00 | 0.00 |
| M CORRIDOR | 5140.67 | 3619.33 | 0.00 | 0.00 | 0.00 |
| Min | 5140.67 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 3619.33 | 89.33 | 0.00 | 0.00 |
| Average | 8376.72 | 378.51 | 4.78 | 0.00 | 0.00 |
| Sum | 226171.33 | 10219.67 | 129.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 16561.33 | 6150.33 | 283.33 | 0.00 | 0.00 |
| G CORRIDOR | 17236.33 | 5726.33 | 32.33 | 0.00 | 0.00 |
| M CORRIDOR | 13436.67 | 9558.33 | 0.00 | 0.00 | 0.00 |
| Min | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 17236.33 | 9558.33 | 283.33 | 0.00 | 0.00 |
| Average | 11532.75 | 793.89 | 11.69 | 0.00 | 0.00 |
| Sum | 311384.33 | 21435.00 | 315.67 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 7746.67 | 1013.33 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 7705.83 | 1054.17 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6039.33 | 2720.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 7744.33 | 1015.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 7722.50 | 1037.50 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 7725.33 | 1034.67 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 7793.83 | 966.17 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 7989.17 | 770.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 7854.17 | 905.83 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 7795.67 | 964.33 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 7879.50 | 880.50 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 7820.17 | 939.83 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 7836.50 | 923.50 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 7837.50 | 922.50 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 7896.00 | 864.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 7897.17 | 862.83 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 7584.17 | 1175.83 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 7570.67 | 1189.33 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 7616.00 | 1144.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 7604.67 | 1155.33 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 7607.33 | 1152.67 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 7609.00 | 1151.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 7636.83 | 1123.17 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 7638.67 | 1121.33 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 3791.00 | 4584.17 | 384.83 | 0.00 | 0.00 |
| G CORRIDOR | 5106.67 | 3548.83 | 104.50 | 0.00 | 0.00 |
| M CORRIDOR | 2631.50 | 5919.50 | 209.00 | 0.00 | 0.00 |
| Min | 2631.50 | 770.83 | 0.00 | 0.00 | 0.00 |
| Max | 7989.17 | 5919.50 | 384.83 | 0.00 | 0.00 |
| Average | 7247.41 | 1486.72 | 25.86 | 0.00 | 0.00 |
| Sum | 195680.17 | 40141.50 | 698.33 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 10319.00 | 1511.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 9237.50 | 1347.50 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6539.33 | 460.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 9195.83 | 1389.17 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 9245.83 | 1339.17 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 9246.50 | 1338.50 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 10370.00 | 1460.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 10661.50 | 1168.50 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 10478.17 | 1351.83 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 9350.83 | 1234.17 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 10443.50 | 1386.50 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 9275.67 | 1309.33 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 9407.00 | 1178.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 9406.67 | 1178.33 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 10539.00 | 1291.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 10538.17 | 1291.83 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 10036.33 | 1793.67 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8984.67 | 1600.33 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 10003.83 | 1826.17 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8916.83 | 1668.17 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 9036.50 | 1548.50 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 9034.17 | 1550.83 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 10113.50 | 1716.50 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 10112.17 | 1717.83 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 9829.33 | 11921.33 | 1244.33 | 0.00 | 0.00 |
| G CORRIDOR | 12893.83 | 9683.17 | 418.00 | 0.00 | 0.00 |
| M CORRIDOR | 6811.67 | 15532.83 | 650.50 | 0.00 | 0.00 |
| Min | 6539.33 | 460.67 | 0.00 | 0.00 | 0.00 |
| Max | 12893.83 | 15532.83 | 1244.33 | 0.00 | 0.00 |
| Average | 9630.64 | 2622.03 | 85.66 | 0.00 | 0.00 |
| Sum | 260027.33 | 70794.83 | 2312.83 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:14:20
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 3.965 |
| February | 7.937 |
| March | 13.764 |
| April | 17.213 |
| May | 20.837 |
| June | 24.797 |
| July | 26.063 |
| August | 26.547 |
| September | 22.525 |
| October | 16.026 |
| November | 11.940 |
| December | 7.696 |
| Annual Sum or Average | 16.653 |
| Minimum of Months | 3.965 |
| Maximum of Months | 26.547 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.112269E+09 | 463.53 | 15-JAN-14:10 | 5.18 | 0.07 | 78921247.61 | 56.76 | 29-JAN-17:49 | 14.60 | 5.92 |
| February | 0.179122E+09 | 588.26 | 26-FEB-17:10 | 23.72 | 11.96 | 74115630.73 | 70.33 | 28-FEB-20:10 | 20.60 | 11.78 |
| March | 0.462992E+09 | 986.98 | 30-MAR-16:17 | 27.43 | 17.59 | 90013161.65 | 70.36 | 30-MAR-23:00 | 20.00 | 15.21 |
| April | 0.657095E+09 | 1100.56 | 17-APR-16:15 | 28.70 | 16.48 | 0.104379E+09 | 70.37 | 14-APR-22:10 | 28.70 | 16.48 |
| May | 0.114200E+10 | 1455.74 | 19-MAY-17:30 | 30.00 | 19.02 | 0.120505E+09 | 70.36 | 14-MAY-21:00 | 30.00 | 19.02 |
| June | 0.217092E+10 | 1889.24 | 06-JUN-17:13 | 33.53 | 21.34 | 0.120159E+09 | 70.36 | 02-JUN-04:00 | 33.53 | 21.34 |
| July | 0.267568E+10 | 1999.48 | 08-JUL-16:30 | 35.55 | 23.66 | 0.129263E+09 | 70.33 | 29-JUL-09:09 | 17.88 | 17.88 |
| August | 0.311396E+10 | 2201.08 | 18-AUG-17:17 | 34.23 | 22.84 | 0.123962E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.239420E+10 | 2081.42 | 07-SEP-16:02 | 31.52 | 23.59 | 0.123639E+09 | 70.36 | 20-SEP-06:10 | 15.68 | 13.45 |
| October | 0.157040E+10 | 2050.96 | 10-OCT-16:03 | 29.82 | 20.51 | 0.119231E+09 | 70.37 | 08-OCT-01:10 | 29.82 | 20.51 |
| November | 0.888931E+09 | 1330.94 | 05-NOV-16:05 | 24.03 | 17.90 | 0.101919E+09 | 70.36 | 15-NOV-19:40 | 13.33 | 8.06 |
| December | 0.382405E+09 | 554.82 | 17-DEC-17:25 | 2.20 | -2.3 | 82725232.71 | 70.36 | 12-DEC-19:10 | 2.20 | -2.3 |
| Annual Sum or Average | 0.157500E+11 | 0.126883E+10 | ||||||||
| Minimum of Months | 0.112269E+09 | 463.53 | 2.20 | -2.3 | 74115630.73 | 56.76 | 2.20 | -2.3 | ||
| Maximum of Months | 0.311396E+10 | 2201.08 | 35.55 | 23.66 | 0.129263E+09 | 70.37 | 33.53 | 21.34 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 18725930.69 | 271.55 | 31-JAN-23:30 | 11.45 | 9.16 | 77995210.12 | 45.94 | 31-JAN-21:10 | 11.45 | 9.16 |
| February | 63304792.36 | 298.86 | 20-FEB-21:40 | 10.57 | 6.74 | 72027254.83 | 60.58 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.222983E+09 | 631.12 | 30-MAR-16:40 | 27.07 | 17.68 | 86395237.52 | 70.30 | 29-MAR-20:40 | 27.07 | 17.68 |
| April | 0.453331E+09 | 817.94 | 17-APR-17:20 | 27.77 | 16.46 | 0.100586E+09 | 70.36 | 18-APR-22:30 | 19.15 | 14.35 |
| May | 0.101756E+10 | 1359.36 | 19-MAY-17:30 | 30.00 | 19.02 | 0.122532E+09 | 70.36 | 24-MAY-01:30 | 18.30 | 15.35 |
| June | 0.215174E+10 | 1879.72 | 06-JUN-17:25 | 33.35 | 21.24 | 0.124387E+09 | 70.37 | 08-JUN-00:40 | 14.47 | 10.29 |
| July | 0.262687E+10 | 1922.64 | 21-JUL-18:00 | 33.30 | 22.96 | 0.128765E+09 | 70.28 | 11-JUL-00:00 | 33.30 | 22.96 |
| August | 0.288868E+10 | 2024.05 | 18-AUG-17:30 | 34.15 | 23.05 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.198425E+10 | 1769.82 | 07-SEP-17:07 | 30.50 | 22.96 | 0.124231E+09 | 70.36 | 19-SEP-04:00 | 14.40 | 12.50 |
| October | 0.103407E+10 | 1317.42 | 10-OCT-16:30 | 29.45 | 20.42 | 0.114727E+09 | 70.36 | 11-OCT-23:49 | 13.48 | 8.22 |
| November | 0.495402E+09 | 743.41 | 05-NOV-16:10 | 24.03 | 17.90 | 90321460.97 | 70.27 | 05-NOV-21:40 | 15.97 | 15.97 |
| December | 0.106881E+09 | 412.90 | 14-DEC-21:00 | 7.20 | 5.64 | 79353168.04 | 57.63 | 12-DEC-23:10 | 7.20 | 5.64 |
| Annual Sum or Average | 0.130638E+11 | 0.125009E+10 | ||||||||
| Minimum of Months | 18725930.69 | 271.55 | 7.20 | 5.64 | 72027254.83 | 45.94 | 7.20 | 5.64 | ||
| Maximum of Months | 0.288868E+10 | 2024.05 | 34.15 | 23.05 | 0.128774E+09 | 70.37 | 33.30 | 22.96 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.433425E+09 | 947.79 | 27-JAN-08:03 | -6.4 | -7.7 | 40604782.17 | 128.15 | 31-JAN-15:39 | 20.37 | 13.40 |
| February | 0.315869E+09 | 1018.50 | 03-FEB-08:03 | -8.6 | -9.9 | 43963485.14 | 133.51 | 21-FEB-16:00 | 21.70 | 10.37 |
| March | 0.336833E+09 | 4474.51 | 31-MAR-08:62 | 18.58 | 16.63 | 67479707.99 | 158.08 | 31-MAR-08:09 | 18.58 | 16.63 |
| April | 0.459635E+09 | 5881.06 | 17-APR-08:62 | 18.17 | 13.18 | 64929278.29 | 166.75 | 18-APR-08:09 | 19.87 | 15.11 |
| May | 0.832037E+09 | 5419.44 | 17-MAY-08:62 | 19.87 | 15.03 | 75986890.74 | 186.20 | 30-MAY-07:10 | 22.07 | 19.14 |
| June | 0.157664E+10 | 5747.53 | 08-JUN-08:62 | 17.57 | 11.08 | 77482429.44 | 217.47 | 26-JUN-07:10 | 23.48 | 21.74 |
| July | 0.172354E+10 | 5050.74 | 25-JUL-07:02 | 21.20 | 18.27 | 70641784.58 | 217.52 | 06-JUL-07:10 | 21.20 | 18.27 |
| August | 0.213385E+10 | 4573.95 | 25-AUG-08:62 | 22.15 | 17.74 | 81286427.34 | 218.30 | 03-AUG-07:10 | 22.15 | 17.74 |
| September | 0.159662E+10 | 5684.23 | 14-SEP-08:62 | 15.55 | 13.29 | 70431998.12 | 217.47 | 05-SEP-07:10 | 15.55 | 13.29 |
| October | 0.109130E+10 | 6057.67 | 12-OCT-08:62 | 10.55 | 7.78 | 70681080.65 | 190.34 | 19-OCT-07:10 | 19.40 | 19.12 |
| November | 0.694128E+09 | 3569.21 | 06-NOV-09:03 | 12.57 | 11.17 | 62345761.23 | 157.99 | 06-NOV-09:09 | 12.57 | 11.17 |
| December | 0.505267E+09 | 2555.13 | 13-DEC-09:03 | 17.38 | 16.26 | 49417332.01 | 151.70 | 13-DEC-09:09 | 17.38 | 16.26 |
| Annual Sum or Average | 0.116991E+11 | 0.775251E+09 | ||||||||
| Minimum of Months | 0.315869E+09 | 947.79 | -8.6 | -9.9 | 40604782.17 | 128.15 | 12.57 | 10.37 | ||
| Maximum of Months | 0.213385E+10 | 6057.67 | 22.15 | 18.27 | 81286427.34 | 218.30 | 23.48 | 21.74 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 18368710.01 | 271.58 | 31-JAN-23:30 | 11.45 | 9.16 | 77983253.06 | 46.08 | 31-JAN-21:10 | 11.45 | 9.16 |
| February | 69326613.02 | 298.44 | 20-FEB-21:40 | 10.57 | 6.74 | 71952032.40 | 60.52 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.215156E+09 | 395.95 | 30-MAR-16:07 | 27.62 | 17.53 | 85550822.21 | 70.35 | 30-MAR-22:30 | 22.25 | 16.14 |
| April | 0.453042E+09 | 622.21 | 19-APR-16:27 | 26.40 | 16.63 | 99855838.30 | 70.37 | 18-APR-22:49 | 26.40 | 16.63 |
| May | 0.103992E+10 | 1070.57 | 19-MAY-18:00 | 29.40 | 18.89 | 0.122473E+09 | 70.37 | 04-MAY-22:40 | 29.40 | 18.89 |
| June | 0.219637E+10 | 1647.27 | 06-JUN-17:05 | 33.72 | 21.43 | 0.124391E+09 | 70.32 | 02-JUN-04:40 | 33.72 | 21.43 |
| July | 0.268087E+10 | 1734.92 | 08-JUL-17:20 | 34.40 | 23.36 | 0.128764E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.289750E+10 | 1772.08 | 19-AUG-16:05 | 32.33 | 24.28 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.199819E+10 | 1569.13 | 07-SEP-16:08 | 31.52 | 23.59 | 0.124222E+09 | 70.34 | 14-SEP-03:30 | 13.35 | 11.85 |
| October | 0.102918E+10 | 1104.29 | 10-OCT-16:10 | 29.82 | 20.51 | 0.114687E+09 | 70.38 | 07-OCT-22:19 | 29.82 | 20.51 |
| November | 0.491018E+09 | 573.73 | 05-NOV-16:10 | 24.03 | 17.90 | 89863037.92 | 70.34 | 05-NOV-21:40 | 15.97 | 15.97 |
| December | 0.100670E+09 | 413.48 | 14-DEC-21:00 | 7.20 | 5.64 | 79272016.27 | 57.27 | 12-DEC-23:10 | 7.20 | 5.64 |
| Annual Sum or Average | 0.131896E+11 | 0.124779E+10 | ||||||||
| Minimum of Months | 18368710.01 | 271.58 | 7.20 | 5.64 | 71952032.40 | 46.08 | 7.20 | 5.64 | ||
| Maximum of Months | 0.289750E+10 | 1772.08 | 34.40 | 24.28 | 0.128774E+09 | 70.38 | 33.72 | 21.43 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 43361423.83 | 278.99 | 20-JAN-22:15 | 11.33 | 8.04 | 78181909.00 | 48.12 | 31-JAN-21:10 | 16.82 | 12.20 |
| February | 0.133225E+09 | 324.48 | 27-FEB-06:10 | 9.82 | 4.76 | 72720569.03 | 61.96 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.359687E+09 | 452.66 | 13-MAR-07:00 | 5.60 | 2.43 | 88652548.35 | 70.29 | 29-MAR-20:30 | 23.35 | 17.15 |
| April | 0.548276E+09 | 601.06 | 19-APR-16:27 | 26.40 | 16.63 | 0.105253E+09 | 70.38 | 17-APR-23:49 | 26.40 | 16.63 |
| May | 0.101004E+10 | 920.90 | 19-MAY-18:00 | 29.40 | 18.89 | 0.125352E+09 | 70.36 | 09-MAY-20:49 | 29.40 | 18.89 |
| June | 0.190765E+10 | 1303.62 | 06-JUN-17:30 | 33.35 | 21.24 | 0.124565E+09 | 70.34 | 09-JUN-03:39 | 14.80 | 9.57 |
| July | 0.226472E+10 | 1386.48 | 08-JUL-17:17 | 34.40 | 23.36 | 0.128775E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.242885E+10 | 1387.25 | 19-AUG-16:05 | 32.33 | 24.28 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.177209E+10 | 1238.59 | 07-SEP-17:17 | 30.40 | 22.94 | 0.124511E+09 | 70.34 | 28-SEP-20:19 | 15.60 | 13.74 |
| October | 0.103519E+10 | 908.86 | 10-OCT-17:10 | 28.43 | 20.32 | 0.119125E+09 | 70.37 | 05-OCT-01:49 | 28.43 | 20.32 |
| November | 0.639962E+09 | 581.35 | 05-NOV-16:10 | 24.03 | 17.90 | 94696031.79 | 70.30 | 04-NOV-20:19 | 24.03 | 17.90 |
| December | 0.241867E+09 | 462.45 | 14-DEC-08:00 | 5.60 | 4.58 | 80049124.68 | 59.34 | 12-DEC-23:10 | 5.60 | 4.58 |
| Annual Sum or Average | 0.123849E+11 | 0.127066E+10 | ||||||||
| Minimum of Months | 43361423.83 | 278.99 | 5.60 | 2.43 | 72720569.03 | 48.12 | 5.60 | 4.58 | ||
| Maximum of Months | 0.242885E+10 | 1387.25 | 34.40 | 24.28 | 0.128775E+09 | 70.38 | 29.40 | 20.62 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 43350133.57 | 276.20 | 20-JAN-22:05 | 11.52 | 8.16 | 78181679.09 | 48.15 | 31-JAN-21:10 | 16.82 | 12.20 |
| February | 0.133618E+09 | 329.96 | 27-FEB-06:20 | 9.63 | 4.65 | 72728862.98 | 62.01 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.358826E+09 | 452.26 | 13-MAR-07:00 | 5.60 | 2.43 | 88602855.07 | 70.36 | 29-MAR-20:19 | 23.53 | 17.17 |
| April | 0.548386E+09 | 601.90 | 19-APR-16:27 | 26.40 | 16.63 | 0.105206E+09 | 70.37 | 19-APR-00:20 | 26.40 | 16.63 |
| May | 0.101252E+10 | 918.20 | 19-MAY-18:00 | 29.40 | 18.89 | 0.125352E+09 | 70.37 | 17-MAY-02:00 | 29.40 | 18.89 |
| June | 0.191016E+10 | 1301.32 | 06-JUN-17:30 | 33.35 | 21.24 | 0.124564E+09 | 70.34 | 09-JUN-03:39 | 14.80 | 9.57 |
| July | 0.226746E+10 | 1384.98 | 08-JUL-17:17 | 34.40 | 23.36 | 0.128775E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.242941E+10 | 1386.35 | 19-AUG-16:05 | 32.33 | 24.28 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.177294E+10 | 1235.95 | 07-SEP-17:17 | 30.40 | 22.94 | 0.124511E+09 | 70.37 | 29-SEP-00:00 | 12.80 | 11.77 |
| October | 0.103731E+10 | 909.55 | 18-OCT-16:15 | 25.40 | 23.15 | 0.119121E+09 | 70.38 | 07-OCT-20:49 | 25.40 | 23.15 |
| November | 0.639709E+09 | 577.43 | 05-NOV-16:10 | 24.03 | 17.90 | 94662639.18 | 70.34 | 05-NOV-22:00 | 15.00 | 15.00 |
| December | 0.242031E+09 | 462.42 | 14-DEC-08:00 | 5.60 | 4.58 | 80044601.04 | 59.30 | 12-DEC-23:10 | 5.60 | 4.58 |
| Annual Sum or Average | 0.123957E+11 | 0.127052E+10 | ||||||||
| Minimum of Months | 43350133.57 | 276.20 | 5.60 | 2.43 | 72728862.98 | 48.15 | 5.60 | 4.58 | ||
| Maximum of Months | 0.242941E+10 | 1386.35 | 34.40 | 24.28 | 0.128775E+09 | 70.38 | 29.40 | 23.15 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.300247E+09 | 544.99 | 15-JAN-12:30 | 2.50 | -2.0 | 79630420.29 | 59.03 | 29-JAN-17:00 | 14.40 | 5.85 |
| February | 0.354276E+09 | 532.63 | 28-FEB-17:05 | 23.72 | 12.85 | 76294010.58 | 70.28 | 28-FEB-22:00 | 17.30 | 10.02 |
| March | 0.649109E+09 | 724.17 | 30-MAR-16:07 | 27.62 | 17.53 | 96358051.99 | 70.35 | 28-MAR-19:19 | 27.62 | 17.53 |
| April | 0.765377E+09 | 859.53 | 17-APR-16:10 | 28.80 | 16.45 | 0.110489E+09 | 70.39 | 11-APR-21:49 | 28.80 | 16.45 |
| May | 0.115399E+10 | 1027.27 | 20-MAY-16:10 | 26.60 | 18.75 | 0.123211E+09 | 70.37 | 12-MAY-22:30 | 26.60 | 18.75 |
| June | 0.193555E+10 | 1319.37 | 25-JUN-16:50 | 32.88 | 22.29 | 0.120357E+09 | 70.36 | 10-JUN-07:10 | 32.88 | 22.29 |
| July | 0.232598E+10 | 1456.40 | 08-JUL-17:05 | 34.40 | 23.36 | 0.129276E+09 | 70.29 | 13-JUL-19:00 | 22.80 | 20.81 |
| August | 0.266989E+10 | 1598.55 | 19-AUG-16:05 | 32.33 | 24.28 | 0.123962E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.220348E+10 | 1598.17 | 23-SEP-16:10 | 28.72 | 18.71 | 0.123890E+09 | 70.35 | 29-SEP-01:19 | 12.60 | 11.60 |
| October | 0.162409E+10 | 1631.40 | 10-OCT-16:03 | 29.82 | 20.51 | 0.123334E+09 | 70.39 | 26-OCT-18:00 | 13.30 | 9.29 |
| November | 0.109267E+10 | 1152.97 | 05-NOV-16:10 | 24.03 | 17.90 | 0.108810E+09 | 70.38 | 13-NOV-19:40 | 10.20 | 5.37 |
| December | 0.709210E+09 | 616.40 | 17-DEC-18:50 | 0.18 | -3.5 | 86168070.99 | 70.30 | 10-DEC-16:30 | 0.18 | -3.5 |
| Annual Sum or Average | 0.157839E+11 | 0.130178E+10 | ||||||||
| Minimum of Months | 0.300247E+09 | 532.63 | 0.18 | -3.5 | 76294010.58 | 59.03 | 0.18 | -3.5 | ||
| Maximum of Months | 0.266989E+10 | 1631.40 | 34.40 | 24.28 | 0.129276E+09 | 70.39 | 32.88 | 22.29 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.251747E+09 | 524.37 | 27-JAN-14:20 | 3.17 | -2.2 | 79377485.02 | 58.04 | 31-JAN-18:10 | 18.72 | 13.14 |
| February | 0.336858E+09 | 559.18 | 28-FEB-15:30 | 24.15 | 13.12 | 76318225.23 | 70.31 | 28-FEB-23:10 | 17.02 | 9.75 |
| March | 0.664207E+09 | 757.90 | 30-MAR-16:07 | 27.62 | 17.53 | 97062941.08 | 70.38 | 13-MAR-23:30 | 27.62 | 17.53 |
| April | 0.809626E+09 | 913.07 | 17-APR-16:05 | 28.80 | 16.45 | 0.111359E+09 | 70.36 | 19-APR-03:00 | 16.10 | 14.43 |
| May | 0.125775E+10 | 1106.92 | 20-MAY-16:10 | 26.60 | 18.75 | 0.123615E+09 | 70.38 | 11-MAY-22:19 | 26.60 | 18.75 |
| June | 0.213076E+10 | 1444.17 | 25-JUN-17:00 | 32.80 | 22.34 | 0.120398E+09 | 70.36 | 09-JUN-03:00 | 32.80 | 22.34 |
| July | 0.258312E+10 | 1587.19 | 08-JUL-17:20 | 34.40 | 23.36 | 0.129276E+09 | 70.29 | 13-JUL-19:00 | 22.80 | 20.81 |
| August | 0.293942E+10 | 1733.42 | 19-AUG-16:05 | 32.33 | 24.28 | 0.123962E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.241571E+10 | 1697.49 | 23-SEP-16:10 | 28.72 | 18.71 | 0.123927E+09 | 70.33 | 29-SEP-02:39 | 12.20 | 11.28 |
| October | 0.172415E+10 | 1696.30 | 10-OCT-16:03 | 29.82 | 20.51 | 0.123795E+09 | 70.38 | 14-OCT-04:19 | 7.97 | 6.27 |
| November | 0.112309E+10 | 1197.30 | 05-NOV-16:10 | 24.03 | 17.90 | 0.109227E+09 | 70.38 | 18-NOV-22:10 | 11.28 | 5.96 |
| December | 0.681419E+09 | 612.23 | 17-DEC-18:35 | 0.37 | -3.4 | 86061983.19 | 70.36 | 10-DEC-16:10 | 0.37 | -3.4 |
| Annual Sum or Average | 0.169178E+11 | 0.130438E+10 | ||||||||
| Minimum of Months | 0.251747E+09 | 524.37 | 0.37 | -3.4 | 76318225.23 | 58.04 | 0.37 | -3.4 | ||
| Maximum of Months | 0.293942E+10 | 1733.42 | 34.40 | 24.28 | 0.129276E+09 | 70.38 | 32.80 | 22.34 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.269013E+09 | 552.17 | 14-JAN-17:35 | 2.40 | -2.4 | 80398932.26 | 65.43 | 29-JAN-17:19 | 15.20 | 6.14 |
| February | 0.452042E+09 | 1418.40 | 26-FEB-16:30 | 24.15 | 12.19 | 79290170.07 | 70.32 | 26-FEB-21:19 | 16.50 | 9.59 |
| March | 0.105280E+10 | 2076.63 | 30-MAR-16:15 | 27.43 | 17.59 | 0.104794E+09 | 70.32 | 10-MAR-23:49 | 27.43 | 17.59 |
| April | 0.156891E+10 | 2034.64 | 15-APR-16:10 | 28.03 | 15.88 | 0.117634E+09 | 70.31 | 25-APR-21:10 | 10.92 | 6.58 |
| May | 0.217199E+10 | 2170.98 | 19-MAY-17:30 | 30.00 | 19.02 | 0.124771E+09 | 70.31 | 13-MAY-19:19 | 30.00 | 19.02 |
| June | 0.290136E+10 | 2443.87 | 06-JUN-17:20 | 33.53 | 21.34 | 0.120344E+09 | 70.30 | 07-JUN-17:49 | 23.40 | 13.82 |
| July | 0.320594E+10 | 2384.03 | 08-JUL-16:30 | 35.55 | 23.66 | 0.129276E+09 | 70.30 | 29-JUL-05:00 | 17.80 | 17.48 |
| August | 0.345095E+10 | 2541.30 | 18-AUG-17:17 | 34.23 | 22.84 | 0.123963E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.247731E+10 | 2453.58 | 23-SEP-16:10 | 28.72 | 18.71 | 0.123324E+09 | 70.30 | 28-SEP-21:49 | 15.10 | 13.32 |
| October | 0.156275E+10 | 2356.74 | 10-OCT-16:03 | 29.82 | 20.51 | 0.116250E+09 | 70.32 | 05-OCT-00:49 | 29.82 | 20.51 |
| November | 0.848914E+09 | 1642.42 | 05-NOV-16:10 | 24.03 | 17.90 | 99956886.47 | 70.31 | 20-NOV-00:20 | 20.53 | 18.35 |
| December | 0.437332E+09 | 817.47 | 12-DEC-14:30 | 22.80 | 16.62 | 84554984.35 | 70.29 | 13-DEC-00:20 | 17.43 | 14.63 |
| Annual Sum or Average | 0.203993E+11 | 0.130456E+10 | ||||||||
| Minimum of Months | 0.269013E+09 | 552.17 | 2.40 | -2.4 | 79290170.07 | 65.43 | 10.92 | 6.14 | ||
| Maximum of Months | 0.345095E+10 | 2541.30 | 35.55 | 23.66 | 0.129276E+09 | 70.32 | 30.00 | 20.51 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 53360231.51 | 311.96 | 31-JAN-24:00 | 10.30 | 8.37 | 78480378.33 | 51.77 | 31-JAN-21:10 | 10.30 | 8.37 |
| February | 0.200769E+09 | 578.69 | 28-FEB-17:10 | 23.72 | 12.85 | 75640918.94 | 70.27 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.675192E+09 | 1662.98 | 30-MAR-16:40 | 27.07 | 17.68 | 0.100693E+09 | 70.30 | 12-MAR-00:20 | 27.07 | 17.68 |
| April | 0.124917E+10 | 1696.24 | 17-APR-17:15 | 27.77 | 16.46 | 0.115820E+09 | 70.31 | 21-APR-05:40 | 15.20 | 14.30 |
| May | 0.202112E+10 | 2063.23 | 19-MAY-17:30 | 30.00 | 19.02 | 0.127596E+09 | 70.30 | 10-MAY-20:40 | 30.00 | 19.02 |
| June | 0.287359E+10 | 2430.76 | 06-JUN-17:25 | 33.35 | 21.24 | 0.124553E+09 | 70.31 | 07-JUN-04:00 | 13.90 | 12.22 |
| July | 0.314309E+10 | 2338.45 | 21-JUL-18:00 | 33.30 | 22.96 | 0.128774E+09 | 70.28 | 11-JUL-00:00 | 33.30 | 22.96 |
| August | 0.320399E+10 | 2423.21 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.203808E+10 | 1975.88 | 07-SEP-16:30 | 31.15 | 23.35 | 0.123904E+09 | 70.31 | 18-SEP-03:49 | 15.00 | 14.05 |
| October | 0.984095E+09 | 1531.78 | 10-OCT-16:30 | 29.45 | 20.42 | 0.111615E+09 | 70.32 | 07-OCT-20:40 | 29.45 | 20.42 |
| November | 0.424490E+09 | 949.04 | 05-NOV-16:10 | 24.03 | 17.90 | 88941982.26 | 70.27 | 05-NOV-21:40 | 15.97 | 15.97 |
| December | 0.134958E+09 | 449.51 | 14-DEC-07:35 | 5.77 | 4.66 | 80284020.77 | 63.04 | 12-DEC-23:10 | 5.77 | 4.66 |
| Annual Sum or Average | 0.170019E+11 | 0.128508E+10 | ||||||||
| Minimum of Months | 53360231.51 | 311.96 | 5.77 | 4.66 | 75640918.94 | 51.77 | 5.77 | 4.66 | ||
| Maximum of Months | 0.320399E+10 | 2430.76 | 35.00 | 23.60 | 0.128774E+09 | 70.32 | 33.30 | 22.96 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.261089E+09 | 581.15 | 15-JAN-11:40 | 1.33 | -2.7 | 80277482.18 | 63.68 | 29-JAN-17:00 | 14.40 | 5.85 |
| February | 0.458615E+09 | 1228.81 | 26-FEB-15:10 | 24.90 | 12.68 | 79408839.40 | 70.28 | 21-FEB-20:10 | 24.90 | 12.68 |
| March | 0.101589E+10 | 1725.36 | 30-MAR-16:10 | 27.62 | 17.53 | 0.104341E+09 | 70.32 | 05-MAR-18:10 | 27.62 | 17.53 |
| April | 0.156028E+10 | 1748.34 | 16-APR-14:00 | 28.90 | 16.19 | 0.117381E+09 | 70.32 | 13-APR-04:10 | 28.90 | 16.19 |
| May | 0.220606E+10 | 1790.21 | 19-MAY-16:08 | 30.60 | 19.33 | 0.124750E+09 | 70.32 | 15-MAY-00:30 | 30.60 | 19.33 |
| June | 0.295250E+10 | 2113.44 | 06-JUN-17:05 | 33.72 | 21.43 | 0.120339E+09 | 70.30 | 07-JUN-17:49 | 23.40 | 13.82 |
| July | 0.326254E+10 | 2133.14 | 08-JUL-16:03 | 36.32 | 23.83 | 0.129275E+09 | 70.30 | 29-JUL-06:00 | 17.80 | 17.80 |
| August | 0.346020E+10 | 2276.19 | 19-AUG-14:00 | 33.90 | 23.86 | 0.123963E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.249325E+10 | 2133.65 | 23-SEP-14:10 | 29.32 | 19.30 | 0.123303E+09 | 70.30 | 15-SEP-23:00 | 29.32 | 19.30 |
| October | 0.156947E+10 | 2095.26 | 10-OCT-14:10 | 29.32 | 20.98 | 0.116036E+09 | 70.32 | 20-OCT-20:19 | 11.50 | 8.78 |
| November | 0.836613E+09 | 1379.72 | 05-NOV-16:10 | 24.03 | 17.90 | 99893624.69 | 70.32 | 09-NOV-21:19 | 14.63 | 11.15 |
| December | 0.445885E+09 | 778.55 | 12-DEC-14:00 | 22.80 | 17.07 | 84357833.09 | 70.30 | 12-DEC-21:19 | 18.30 | 14.62 |
| Annual Sum or Average | 0.205224E+11 | 0.130333E+10 | ||||||||
| Minimum of Months | 0.261089E+09 | 581.15 | 1.33 | -2.7 | 79408839.40 | 63.68 | 11.50 | 5.85 | ||
| Maximum of Months | 0.346020E+10 | 2276.19 | 36.32 | 23.86 | 0.129275E+09 | 70.32 | 30.60 | 19.33 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 50260294.58 | 312.56 | 31-JAN-24:00 | 10.30 | 8.37 | 78449308.94 | 51.94 | 31-JAN-21:10 | 10.30 | 8.37 |
| February | 0.209095E+09 | 475.47 | 28-FEB-17:05 | 23.72 | 12.85 | 75638746.54 | 70.27 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.652677E+09 | 1296.06 | 30-MAR-16:07 | 27.62 | 17.53 | 99875515.27 | 70.29 | 13-MAR-23:00 | 27.62 | 17.53 |
| April | 0.123765E+10 | 1324.73 | 16-APR-16:20 | 26.70 | 16.02 | 0.115642E+09 | 70.32 | 14-APR-04:49 | 26.70 | 16.02 |
| May | 0.205472E+10 | 1631.30 | 30-MAY-15:10 | 30.13 | 21.49 | 0.127601E+09 | 70.32 | 13-MAY-23:40 | 30.13 | 21.49 |
| June | 0.292522E+10 | 2094.57 | 06-JUN-17:05 | 33.72 | 21.43 | 0.124546E+09 | 70.31 | 11-JUN-05:10 | 14.05 | 10.26 |
| July | 0.319975E+10 | 2004.82 | 08-JUL-19:00 | 31.70 | 23.33 | 0.128774E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.321318E+10 | 2114.44 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.205318E+10 | 1697.00 | 07-SEP-16:03 | 31.52 | 23.59 | 0.123888E+09 | 70.30 | 19-SEP-02:49 | 15.10 | 13.10 |
| October | 0.974607E+09 | 1237.39 | 10-OCT-16:08 | 29.82 | 20.51 | 0.111632E+09 | 70.31 | 07-OCT-22:19 | 29.82 | 20.51 |
| November | 0.422268E+09 | 712.59 | 05-NOV-16:10 | 24.03 | 17.90 | 88384356.15 | 70.28 | 05-NOV-21:19 | 16.33 | 16.33 |
| December | 0.126965E+09 | 455.89 | 14-DEC-08:00 | 5.60 | 4.58 | 80166715.63 | 62.60 | 12-DEC-23:10 | 5.60 | 4.58 |
| Annual Sum or Average | 0.171196E+11 | 0.128337E+10 | ||||||||
| Minimum of Months | 50260294.58 | 312.56 | 5.60 | 4.58 | 75638746.54 | 51.94 | 5.60 | 4.58 | ||
| Maximum of Months | 0.321318E+10 | 2114.44 | 35.00 | 23.60 | 0.128774E+09 | 70.32 | 30.13 | 21.49 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.147480E+09 | 376.33 | 21-JAN-02:20 | 8.13 | 4.88 | 78984435.60 | 54.08 | 31-JAN-21:10 | 16.82 | 12.20 |
| February | 0.301002E+09 | 486.76 | 23-FEB-08:00 | 5.00 | 3.70 | 78268863.04 | 70.27 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.773853E+09 | 1068.22 | 30-MAR-16:20 | 27.43 | 17.59 | 0.105494E+09 | 70.29 | 12-MAR-03:09 | 27.43 | 17.59 |
| April | 0.119637E+10 | 1095.35 | 19-APR-16:27 | 26.40 | 16.63 | 0.118439E+09 | 70.30 | 24-APR-05:40 | 13.50 | 13.50 |
| May | 0.178177E+10 | 1296.78 | 19-MAY-18:00 | 29.40 | 18.89 | 0.128288E+09 | 70.31 | 10-MAY-22:40 | 29.40 | 18.89 |
| June | 0.237332E+10 | 1580.49 | 06-JUN-17:25 | 33.35 | 21.24 | 0.124613E+09 | 70.28 | 15-JUN-00:00 | 23.30 | 18.82 |
| July | 0.257067E+10 | 1549.02 | 15-JUL-17:08 | 33.30 | 24.04 | 0.128775E+09 | 70.28 | 11-JUL-00:00 | 33.30 | 24.04 |
| August | 0.259831E+10 | 1565.93 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.180252E+10 | 1297.28 | 07-SEP-16:20 | 31.33 | 23.47 | 0.124400E+09 | 70.30 | 15-SEP-23:00 | 23.30 | 17.48 |
| October | 0.103066E+10 | 1011.10 | 10-OCT-16:17 | 29.63 | 20.46 | 0.117092E+09 | 70.32 | 05-OCT-00:49 | 29.63 | 20.46 |
| November | 0.623179E+09 | 744.78 | 05-NOV-16:05 | 24.03 | 17.90 | 94120843.10 | 70.31 | 03-NOV-20:00 | 24.03 | 17.90 |
| December | 0.331241E+09 | 490.41 | 15-DEC-04:00 | 4.40 | 1.70 | 81658293.26 | 65.80 | 12-DEC-23:10 | 4.40 | 1.70 |
| Annual Sum or Average | 0.155304E+11 | 0.130891E+10 | ||||||||
| Minimum of Months | 0.147480E+09 | 376.33 | 4.40 | 1.70 | 78268863.04 | 54.08 | 4.40 | 1.70 | ||
| Maximum of Months | 0.259831E+10 | 1580.49 | 35.00 | 24.04 | 0.128775E+09 | 70.32 | 33.30 | 24.04 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.147267E+09 | 374.81 | 21-JAN-02:70 | 8.22 | 4.95 | 78984470.82 | 54.12 | 31-JAN-21:10 | 16.82 | 12.20 |
| February | 0.301714E+09 | 487.00 | 23-FEB-08:00 | 5.00 | 3.70 | 78288756.95 | 70.27 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.772852E+09 | 1063.54 | 30-MAR-16:20 | 27.43 | 17.59 | 0.105457E+09 | 70.29 | 29-MAR-01:19 | 27.43 | 17.59 |
| April | 0.119764E+10 | 1094.32 | 19-APR-16:27 | 26.40 | 16.63 | 0.118447E+09 | 70.29 | 24-APR-05:40 | 13.50 | 13.50 |
| May | 0.178411E+10 | 1291.44 | 19-MAY-18:00 | 29.40 | 18.89 | 0.128287E+09 | 70.30 | 10-MAY-22:40 | 29.40 | 18.89 |
| June | 0.237550E+10 | 1576.99 | 06-JUN-17:25 | 33.35 | 21.24 | 0.124613E+09 | 70.28 | 15-JUN-00:00 | 23.30 | 18.82 |
| July | 0.257304E+10 | 1547.36 | 08-JUL-19:00 | 31.70 | 23.33 | 0.128775E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.259887E+10 | 1563.84 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128774E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.180344E+10 | 1296.15 | 07-SEP-16:20 | 31.33 | 23.47 | 0.124399E+09 | 70.30 | 15-SEP-23:00 | 23.30 | 17.48 |
| October | 0.103333E+10 | 1008.99 | 10-OCT-16:17 | 29.63 | 20.46 | 0.117097E+09 | 70.32 | 07-OCT-23:10 | 29.63 | 20.46 |
| November | 0.622661E+09 | 740.49 | 05-NOV-16:05 | 24.03 | 17.90 | 94076345.68 | 70.31 | 04-NOV-05:10 | 24.03 | 17.90 |
| December | 0.331386E+09 | 490.51 | 15-DEC-04:00 | 4.40 | 1.70 | 81651310.92 | 65.74 | 12-DEC-23:10 | 4.40 | 1.70 |
| Annual Sum or Average | 0.155418E+11 | 0.130885E+10 | ||||||||
| Minimum of Months | 0.147267E+09 | 374.81 | 4.40 | 1.70 | 78288756.95 | 54.12 | 4.40 | 1.70 | ||
| Maximum of Months | 0.259887E+10 | 1576.99 | 35.00 | 23.60 | 0.128775E+09 | 70.32 | 29.63 | 20.62 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.576159E+09 | 643.40 | 11-JAN-23:10 | -0.7 | -2.5 | 82574374.39 | 67.98 | 29-JAN-17:00 | 14.40 | 5.85 |
| February | 0.675409E+09 | 1249.26 | 26-FEB-16:10 | 24.32 | 12.30 | 83985362.46 | 70.32 | 21-FEB-23:40 | 24.32 | 12.30 |
| March | 0.117968E+10 | 1492.52 | 30-MAR-16:07 | 27.62 | 17.53 | 0.111272E+09 | 70.31 | 13-MAR-18:30 | 27.62 | 17.53 |
| April | 0.151949E+10 | 1446.65 | 15-APR-16:07 | 28.03 | 15.88 | 0.120541E+09 | 70.31 | 04-APR-02:20 | 28.03 | 15.88 |
| May | 0.193527E+10 | 1405.50 | 19-MAY-16:03 | 30.60 | 19.33 | 0.125388E+09 | 70.31 | 13-MAY-01:00 | 30.60 | 19.33 |
| June | 0.240052E+10 | 1591.97 | 06-JUN-17:08 | 33.72 | 21.43 | 0.120413E+09 | 70.31 | 08-JUN-02:30 | 12.25 | 9.59 |
| July | 0.263371E+10 | 1630.63 | 08-JUL-16:03 | 36.32 | 23.83 | 0.129276E+09 | 70.29 | 13-JUL-19:00 | 22.80 | 20.81 |
| August | 0.284648E+10 | 1763.83 | 29-AUG-16:03 | 32.20 | 22.08 | 0.123963E+09 | 70.28 | 27-AUG-00:00 | 32.20 | 22.08 |
| September | 0.224866E+10 | 1818.76 | 23-SEP-15:20 | 28.90 | 19.11 | 0.123789E+09 | 70.31 | 28-SEP-19:40 | 15.60 | 13.84 |
| October | 0.165131E+10 | 1819.36 | 10-OCT-15:10 | 29.08 | 20.63 | 0.121672E+09 | 70.31 | 23-OCT-20:30 | 13.30 | 12.35 |
| November | 0.110553E+10 | 1389.46 | 05-NOV-16:10 | 24.03 | 17.90 | 0.108237E+09 | 70.32 | 03-NOV-01:10 | 24.03 | 17.90 |
| December | 0.809472E+09 | 954.81 | 12-DEC-14:00 | 22.80 | 17.07 | 89441522.90 | 70.28 | 10-DEC-20:19 | 22.80 | 17.07 |
| Annual Sum or Average | 0.195817E+11 | 0.134055E+10 | ||||||||
| Minimum of Months | 0.576159E+09 | 643.40 | -0.7 | -2.5 | 82574374.39 | 67.98 | 12.25 | 5.85 | ||
| Maximum of Months | 0.284648E+10 | 1819.36 | 36.32 | 23.83 | 0.129276E+09 | 70.32 | 32.20 | 22.08 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.575641E+09 | 643.12 | 11-JAN-23:10 | -0.7 | -2.5 | 82571179.65 | 68.00 | 29-JAN-17:00 | 14.40 | 5.85 |
| February | 0.678054E+09 | 1260.31 | 26-FEB-15:10 | 24.90 | 12.68 | 83999766.91 | 70.32 | 21-FEB-23:19 | 24.90 | 12.68 |
| March | 0.118080E+10 | 1488.04 | 30-MAR-16:07 | 27.62 | 17.53 | 0.111252E+09 | 70.32 | 02-MAR-20:30 | 27.62 | 17.53 |
| April | 0.152107E+10 | 1444.32 | 15-APR-16:07 | 28.03 | 15.88 | 0.120540E+09 | 70.32 | 24-APR-23:49 | 12.70 | 10.55 |
| May | 0.193759E+10 | 1404.61 | 19-MAY-16:03 | 30.60 | 19.33 | 0.125386E+09 | 70.31 | 13-MAY-19:19 | 30.60 | 19.33 |
| June | 0.240279E+10 | 1589.17 | 06-JUN-17:08 | 33.72 | 21.43 | 0.120413E+09 | 70.32 | 08-JUN-02:39 | 12.43 | 9.59 |
| July | 0.263610E+10 | 1630.06 | 08-JUL-16:03 | 36.32 | 23.83 | 0.129276E+09 | 70.29 | 13-JUL-19:00 | 22.80 | 20.81 |
| August | 0.284704E+10 | 1762.66 | 29-AUG-16:03 | 32.20 | 22.08 | 0.123963E+09 | 70.28 | 27-AUG-00:00 | 32.20 | 22.08 |
| September | 0.224948E+10 | 1819.78 | 23-SEP-15:20 | 28.90 | 19.11 | 0.123789E+09 | 70.31 | 28-SEP-19:40 | 15.60 | 13.84 |
| October | 0.165319E+10 | 1821.93 | 10-OCT-14:10 | 29.32 | 20.98 | 0.121648E+09 | 70.30 | 07-OCT-16:00 | 29.32 | 20.98 |
| November | 0.110630E+10 | 1385.08 | 05-NOV-16:10 | 24.03 | 17.90 | 0.108238E+09 | 70.32 | 10-NOV-21:30 | 12.80 | 10.25 |
| December | 0.809598E+09 | 955.38 | 12-DEC-14:00 | 22.80 | 17.07 | 89441992.00 | 70.27 | 10-DEC-16:19 | 22.80 | 17.07 |
| Annual Sum or Average | 0.195977E+11 | 0.134052E+10 | ||||||||
| Minimum of Months | 0.575641E+09 | 643.12 | -0.7 | -2.5 | 82571179.65 | 68.00 | 12.43 | 5.85 | ||
| Maximum of Months | 0.284704E+10 | 1821.93 | 36.32 | 23.83 | 0.129276E+09 | 70.32 | 32.20 | 22.08 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.128275E+09 | 629.09 | 29-JAN-15:00 | 15.60 | 6.41 | 79967322.65 | 70.27 | 29-JAN-16:19 | 16.33 | 6.57 |
| February | 0.297994E+09 | 2165.91 | 26-FEB-16:30 | 24.15 | 12.19 | 75367773.25 | 70.28 | 21-FEB-20:10 | 24.15 | 12.19 |
| March | 0.758110E+09 | 2788.02 | 30-MAR-16:17 | 27.43 | 17.59 | 94044061.50 | 70.37 | 09-MAR-21:10 | 27.43 | 17.59 |
| April | 0.141517E+10 | 2699.55 | 17-APR-16:15 | 28.70 | 16.48 | 0.105670E+09 | 70.36 | 16-APR-23:49 | 28.70 | 16.48 |
| May | 0.220562E+10 | 2975.10 | 19-MAY-17:30 | 30.00 | 19.02 | 0.118673E+09 | 70.35 | 21-MAY-01:30 | 16.95 | 15.40 |
| June | 0.322116E+10 | 3366.90 | 06-JUN-17:10 | 33.72 | 21.43 | 0.118771E+09 | 70.36 | 08-JUN-23:40 | 16.87 | 11.46 |
| July | 0.362672E+10 | 3443.52 | 08-JUL-16:17 | 35.93 | 23.74 | 0.129021E+09 | 70.33 | 28-JUL-04:10 | 19.40 | 19.40 |
| August | 0.389693E+10 | 3607.69 | 01-AUG-17:00 | 35.00 | 23.60 | 0.123939E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.245592E+10 | 3262.33 | 23-SEP-16:05 | 28.72 | 18.71 | 0.119717E+09 | 70.34 | 22-SEP-23:00 | 28.72 | 18.71 |
| October | 0.122670E+10 | 3027.85 | 10-OCT-16:03 | 29.82 | 20.51 | 0.101950E+09 | 70.35 | 19-OCT-21:00 | 16.70 | 15.65 |
| November | 0.513198E+09 | 1988.10 | 05-NOV-16:10 | 24.03 | 17.90 | 88693603.56 | 70.34 | 03-NOV-21:49 | 24.03 | 17.90 |
| December | 0.222308E+09 | 1007.99 | 10-DEC-16:10 | 18.62 | 9.23 | 81613819.12 | 70.27 | 10-DEC-16:19 | 18.33 | 9.11 |
| Annual Sum or Average | 0.199681E+11 | 0.123743E+10 | ||||||||
| Minimum of Months | 0.128275E+09 | 629.09 | 15.60 | 6.41 | 75367773.25 | 70.27 | 16.33 | 6.57 | ||
| Maximum of Months | 0.389693E+10 | 3607.69 | 35.93 | 23.74 | 0.129021E+09 | 70.37 | 28.72 | 19.40 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 24335538.15 | 271.73 | 31-JAN-23:30 | 11.45 | 9.16 | 78282745.71 | 51.49 | 31-JAN-21:10 | 11.45 | 9.16 |
| February | 0.104941E+09 | 834.26 | 26-FEB-17:10 | 23.72 | 11.96 | 73919523.02 | 69.16 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.421935E+09 | 2265.36 | 30-MAR-16:30 | 27.25 | 17.64 | 93294134.32 | 70.35 | 30-MAR-01:39 | 27.25 | 17.64 |
| April | 0.110231E+10 | 2252.76 | 17-APR-17:05 | 28.03 | 16.54 | 0.104841E+09 | 70.35 | 19-APR-22:00 | 16.10 | 14.75 |
| May | 0.204010E+10 | 2827.81 | 19-MAY-17:30 | 30.00 | 19.02 | 0.121335E+09 | 70.35 | 24-MAY-01:39 | 18.30 | 15.51 |
| June | 0.318148E+10 | 3334.01 | 06-JUN-17:20 | 33.53 | 21.34 | 0.123037E+09 | 70.33 | 02-JUN-03:09 | 33.53 | 21.34 |
| July | 0.355563E+10 | 3237.32 | 08-JUL-16:30 | 35.55 | 23.66 | 0.128553E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.362230E+10 | 3460.55 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128749E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.198617E+10 | 2745.59 | 07-SEP-16:17 | 31.33 | 23.47 | 0.119904E+09 | 70.35 | 19-SEP-23:00 | 17.80 | 14.77 |
| October | 0.668074E+09 | 1985.87 | 10-OCT-16:17 | 29.63 | 20.46 | 99129142.93 | 70.34 | 09-OCT-23:40 | 29.63 | 20.46 |
| November | 0.184113E+09 | 1066.85 | 05-NOV-16:10 | 24.03 | 17.90 | 83727255.22 | 68.83 | 19-NOV-22:40 | 21.70 | 18.24 |
| December | 47680179.76 | 280.38 | 14-DEC-00:50 | 11.20 | 10.40 | 79475314.40 | 63.35 | 12-DEC-23:10 | 11.20 | 10.40 |
| Annual Sum or Average | 0.169391E+11 | 0.123425E+10 | ||||||||
| Minimum of Months | 24335538.15 | 271.73 | 11.20 | 9.16 | 73919523.02 | 51.49 | 11.20 | 9.16 | ||
| Maximum of Months | 0.362230E+10 | 3460.55 | 35.55 | 23.66 | 0.128749E+09 | 70.35 | 33.53 | 21.34 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.123373E+09 | 655.29 | 29-JAN-15:00 | 15.60 | 6.41 | 79714599.23 | 70.27 | 29-JAN-16:10 | 16.52 | 6.64 |
| February | 0.295196E+09 | 1849.23 | 26-FEB-15:00 | 25.00 | 12.75 | 75289966.45 | 70.28 | 26-FEB-17:40 | 23.17 | 11.79 |
| March | 0.702490E+09 | 2369.68 | 30-MAR-15:10 | 27.80 | 17.14 | 93164377.88 | 70.35 | 14-MAR-19:30 | 27.80 | 17.14 |
| April | 0.138728E+10 | 2396.69 | 16-APR-14:00 | 28.90 | 16.19 | 0.105034E+09 | 70.36 | 19-APR-00:49 | 16.97 | 14.33 |
| May | 0.222693E+10 | 2499.45 | 30-MAY-15:10 | 30.13 | 21.49 | 0.118634E+09 | 70.36 | 18-MAY-02:49 | 30.13 | 21.49 |
| June | 0.327373E+10 | 2976.50 | 06-JUN-14:10 | 33.98 | 22.08 | 0.118796E+09 | 70.35 | 10-JUN-01:10 | 15.60 | 9.84 |
| July | 0.368627E+10 | 3056.34 | 08-JUL-16:03 | 36.32 | 23.83 | 0.129003E+09 | 70.33 | 03-JUL-03:30 | 36.32 | 23.83 |
| August | 0.390499E+10 | 3225.56 | 19-AUG-14:00 | 33.90 | 23.86 | 0.123937E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.246898E+10 | 2970.08 | 06-SEP-13:20 | 31.10 | 23.78 | 0.119624E+09 | 70.36 | 21-SEP-02:09 | 19.22 | 15.54 |
| October | 0.120386E+10 | 2741.38 | 10-OCT-14:10 | 29.32 | 20.98 | 0.101768E+09 | 70.36 | 06-OCT-18:49 | 29.32 | 20.98 |
| November | 0.488029E+09 | 1620.44 | 05-NOV-16:10 | 24.03 | 17.90 | 88394161.18 | 70.36 | 15-NOV-19:10 | 14.13 | 8.31 |
| December | 0.212957E+09 | 946.44 | 12-DEC-14:20 | 22.80 | 16.78 | 81372332.52 | 70.28 | 12-DEC-19:49 | 19.40 | 15.03 |
| Annual Sum or Average | 0.199741E+11 | 0.123473E+10 | ||||||||
| Minimum of Months | 0.123373E+09 | 655.29 | 15.60 | 6.41 | 75289966.45 | 70.27 | 14.13 | 6.64 | ||
| Maximum of Months | 0.390499E+10 | 3225.56 | 36.32 | 23.86 | 0.129003E+09 | 70.36 | 36.32 | 23.83 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 22987948.19 | 271.74 | 31-JAN-23:30 | 11.45 | 9.16 | 78222170.23 | 51.37 | 31-JAN-21:10 | 11.45 | 9.16 |
| February | 97133816.38 | 606.22 | 28-FEB-17:10 | 23.72 | 12.85 | 73738262.35 | 68.65 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.388721E+09 | 1772.37 | 30-MAR-16:10 | 27.62 | 17.53 | 91932268.95 | 70.35 | 11-MAR-21:00 | 27.62 | 17.53 |
| April | 0.106710E+10 | 1726.07 | 16-APR-16:10 | 26.70 | 16.15 | 0.104316E+09 | 70.36 | 15-APR-23:00 | 26.70 | 16.15 |
| May | 0.206151E+10 | 2326.59 | 30-MAY-15:10 | 30.13 | 21.49 | 0.121285E+09 | 70.36 | 06-MAY-00:00 | 30.13 | 21.49 |
| June | 0.323532E+10 | 2834.00 | 06-JUN-17:00 | 33.90 | 21.53 | 0.123069E+09 | 70.35 | 06-JUN-02:09 | 33.90 | 21.53 |
| July | 0.361558E+10 | 2830.10 | 08-JUL-16:03 | 36.32 | 23.83 | 0.128535E+09 | 70.34 | 03-JUL-05:10 | 36.32 | 23.83 |
| August | 0.363030E+10 | 2968.55 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128748E+09 | 70.34 | 25-AUG-05:10 | 19.22 | 17.80 |
| September | 0.199589E+10 | 2326.79 | 07-SEP-16:10 | 31.52 | 23.59 | 0.119855E+09 | 70.35 | 26-SEP-05:00 | 20.00 | 17.78 |
| October | 0.640013E+09 | 1599.11 | 02-OCT-15:10 | 26.70 | 20.27 | 98702796.64 | 70.35 | 08-OCT-21:10 | 18.80 | 16.64 |
| November | 0.172751E+09 | 738.63 | 05-NOV-16:10 | 24.03 | 17.90 | 82915954.71 | 68.71 | 03-NOV-21:49 | 24.03 | 17.90 |
| December | 40886725.06 | 280.85 | 14-DEC-00:50 | 11.20 | 10.40 | 79350180.06 | 63.00 | 12-DEC-23:10 | 11.20 | 10.40 |
| Annual Sum or Average | 0.169682E+11 | 0.123067E+10 | ||||||||
| Minimum of Months | 22987948.19 | 271.74 | 11.20 | 9.16 | 73738262.35 | 51.37 | 11.20 | 9.16 | ||
| Maximum of Months | 0.363030E+10 | 2968.55 | 36.32 | 23.83 | 0.128748E+09 | 70.36 | 36.32 | 23.83 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 33501189.03 | 300.68 | 31-JAN-23:50 | 10.68 | 8.64 | 78519019.99 | 53.92 | 31-JAN-21:10 | 10.68 | 8.64 |
| February | 0.123935E+09 | 490.33 | 28-FEB-17:10 | 23.72 | 12.85 | 74482429.94 | 69.98 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.423108E+09 | 1475.96 | 30-MAR-16:15 | 27.43 | 17.59 | 94181863.13 | 70.33 | 31-MAR-02:20 | 18.13 | 15.15 |
| April | 0.961959E+09 | 1397.82 | 16-APR-16:20 | 26.70 | 16.02 | 0.107643E+09 | 70.36 | 16-APR-01:10 | 26.70 | 16.02 |
| May | 0.173226E+10 | 1806.07 | 30-MAY-15:10 | 30.13 | 21.49 | 0.123727E+09 | 70.36 | 18-MAY-04:00 | 30.13 | 21.49 |
| June | 0.263301E+10 | 2228.31 | 06-JUN-17:20 | 33.53 | 21.34 | 0.123642E+09 | 70.38 | 11-JUN-02:49 | 16.47 | 11.01 |
| July | 0.293605E+10 | 2260.11 | 08-JUL-16:13 | 35.93 | 23.74 | 0.128715E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.297209E+10 | 2326.40 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128766E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.170966E+10 | 1861.06 | 07-SEP-16:08 | 31.52 | 23.59 | 0.121486E+09 | 70.34 | 13-SEP-22:00 | 16.00 | 13.56 |
| October | 0.641162E+09 | 1307.60 | 02-OCT-16:15 | 26.33 | 20.34 | 0.101347E+09 | 70.33 | 11-OCT-01:49 | 18.07 | 16.58 |
| November | 0.229328E+09 | 722.09 | 05-NOV-16:10 | 24.03 | 17.90 | 84947213.15 | 70.35 | 19-NOV-22:49 | 21.70 | 18.28 |
| December | 67124671.92 | 336.07 | 14-DEC-19:40 | 9.47 | 7.15 | 79860004.95 | 66.65 | 12-DEC-23:10 | 9.47 | 7.15 |
| Annual Sum or Average | 0.144632E+11 | 0.124732E+10 | ||||||||
| Minimum of Months | 33501189.03 | 300.68 | 9.47 | 7.15 | 74482429.94 | 53.92 | 9.47 | 7.15 | ||
| Maximum of Months | 0.297209E+10 | 2326.40 | 35.93 | 23.74 | 0.128766E+09 | 70.38 | 30.13 | 21.49 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 33561242.56 | 300.72 | 31-JAN-23:50 | 10.68 | 8.64 | 78515257.78 | 53.93 | 31-JAN-21:10 | 10.68 | 8.64 |
| February | 0.124167E+09 | 487.41 | 28-FEB-17:10 | 23.72 | 12.85 | 74477603.69 | 69.97 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.422130E+09 | 1466.97 | 30-MAR-16:07 | 27.62 | 17.53 | 94086293.39 | 70.33 | 30-MAR-02:39 | 27.62 | 17.53 |
| April | 0.964220E+09 | 1396.72 | 16-APR-16:20 | 26.70 | 16.02 | 0.107585E+09 | 70.36 | 11-APR-22:40 | 26.70 | 16.02 |
| May | 0.173617E+10 | 1808.80 | 30-MAY-15:10 | 30.13 | 21.49 | 0.123711E+09 | 70.36 | 05-MAY-01:19 | 30.13 | 21.49 |
| June | 0.263666E+10 | 2218.49 | 06-JUN-17:05 | 33.72 | 21.43 | 0.123639E+09 | 70.38 | 07-JUN-23:19 | 16.67 | 11.37 |
| July | 0.293905E+10 | 2254.52 | 08-JUL-16:13 | 35.93 | 23.74 | 0.128714E+09 | 70.28 | 11-JUL-00:00 | 23.30 | 20.62 |
| August | 0.297296E+10 | 2318.03 | 01-AUG-17:00 | 35.00 | 23.60 | 0.128765E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.171175E+10 | 1856.44 | 07-SEP-16:08 | 31.52 | 23.59 | 0.121475E+09 | 70.33 | 21-SEP-02:49 | 18.48 | 15.29 |
| October | 0.642470E+09 | 1303.50 | 02-OCT-16:15 | 26.33 | 20.34 | 0.101318E+09 | 70.32 | 11-OCT-01:49 | 18.07 | 16.58 |
| November | 0.228451E+09 | 713.73 | 05-NOV-16:10 | 24.03 | 17.90 | 84874969.12 | 70.33 | 19-NOV-22:49 | 21.70 | 18.28 |
| December | 66735077.56 | 336.08 | 14-DEC-19:40 | 9.47 | 7.15 | 79850682.24 | 66.60 | 12-DEC-23:10 | 9.47 | 7.15 |
| Annual Sum or Average | 0.144783E+11 | 0.124701E+10 | ||||||||
| Minimum of Months | 33561242.56 | 300.72 | 9.47 | 7.15 | 74477603.69 | 53.93 | 9.47 | 7.15 | ||
| Maximum of Months | 0.297296E+10 | 2318.03 | 35.93 | 23.74 | 0.128765E+09 | 70.38 | 30.13 | 21.49 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.224693E+09 | 715.95 | 29-JAN-15:00 | 15.60 | 6.41 | 80652678.21 | 70.30 | 28-JAN-16:00 | 15.60 | 6.41 |
| February | 0.372495E+09 | 1644.89 | 26-FEB-15:10 | 24.90 | 12.68 | 76914009.80 | 70.35 | 25-FEB-19:10 | 24.90 | 12.68 |
| March | 0.773318E+09 | 2049.05 | 30-MAR-15:10 | 27.80 | 17.14 | 96958143.56 | 70.37 | 25-MAR-19:19 | 27.80 | 17.14 |
| April | 0.127979E+10 | 1950.68 | 16-APR-14:10 | 28.62 | 16.11 | 0.109181E+09 | 70.37 | 16-APR-01:39 | 28.62 | 16.11 |
| May | 0.190021E+10 | 2043.46 | 19-MAY-16:05 | 30.60 | 19.33 | 0.121079E+09 | 70.35 | 21-MAY-02:30 | 16.40 | 15.20 |
| June | 0.267189E+10 | 2314.14 | 24-JUN-16:04 | 33.22 | 22.12 | 0.119387E+09 | 70.31 | 02-JUN-03:00 | 33.22 | 22.12 |
| July | 0.300776E+10 | 2482.11 | 08-JUL-16:03 | 36.32 | 23.83 | 0.129199E+09 | 70.30 | 28-JUL-05:40 | 19.40 | 19.40 |
| August | 0.324885E+10 | 2515.19 | 19-AUG-14:00 | 33.90 | 23.86 | 0.123955E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.218837E+10 | 2476.75 | 23-SEP-15:20 | 28.90 | 19.11 | 0.121255E+09 | 70.37 | 15-SEP-00:40 | 28.90 | 19.11 |
| October | 0.122762E+10 | 2402.48 | 10-OCT-14:10 | 29.32 | 20.98 | 0.105910E+09 | 70.35 | 20-OCT-17:49 | 15.97 | 10.24 |
| November | 0.599510E+09 | 1617.66 | 05-NOV-16:05 | 24.03 | 17.90 | 92366741.89 | 70.36 | 02-NOV-20:40 | 24.03 | 17.90 |
| December | 0.324012E+09 | 977.54 | 12-DEC-14:20 | 22.80 | 16.78 | 83114359.48 | 70.33 | 13-DEC-00:10 | 17.62 | 14.70 |
| Annual Sum or Average | 0.178185E+11 | 0.125997E+10 | ||||||||
| Minimum of Months | 0.224693E+09 | 715.95 | 15.60 | 6.41 | 76914009.80 | 70.28 | 15.60 | 6.41 | ||
| Maximum of Months | 0.324885E+10 | 2515.19 | 36.32 | 23.86 | 0.129199E+09 | 70.37 | 33.22 | 22.12 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.224917E+09 | 731.14 | 29-JAN-15:00 | 15.60 | 6.41 | 80637510.51 | 70.27 | 29-JAN-17:40 | 14.80 | 6.00 |
| February | 0.374381E+09 | 1655.03 | 26-FEB-15:10 | 24.90 | 12.68 | 76908258.19 | 70.37 | 25-FEB-19:10 | 24.90 | 12.68 |
| March | 0.774058E+09 | 2046.79 | 30-MAR-15:10 | 27.80 | 17.14 | 96892173.63 | 70.35 | 30-MAR-02:00 | 27.80 | 17.14 |
| April | 0.128258E+10 | 1961.49 | 16-APR-14:10 | 28.62 | 16.11 | 0.109108E+09 | 70.37 | 16-APR-01:49 | 28.62 | 16.11 |
| May | 0.190426E+10 | 2037.51 | 19-MAY-16:05 | 30.60 | 19.33 | 0.121059E+09 | 70.35 | 07-MAY-03:30 | 30.60 | 19.33 |
| June | 0.267569E+10 | 2307.71 | 24-JUN-16:04 | 33.22 | 22.12 | 0.119382E+09 | 70.37 | 11-JUN-02:49 | 33.22 | 22.12 |
| July | 0.301083E+10 | 2477.36 | 08-JUL-16:03 | 36.32 | 23.83 | 0.129198E+09 | 70.29 | 13-JUL-19:00 | 22.80 | 20.81 |
| August | 0.324975E+10 | 2521.51 | 19-AUG-14:00 | 33.90 | 23.86 | 0.123954E+09 | 70.28 | 27-AUG-00:00 | 23.30 | 19.24 |
| September | 0.219028E+10 | 2476.32 | 23-SEP-15:20 | 28.90 | 19.11 | 0.121244E+09 | 70.35 | 15-SEP-00:40 | 28.90 | 19.11 |
| October | 0.123092E+10 | 2409.32 | 10-OCT-14:10 | 29.32 | 20.98 | 0.105876E+09 | 70.35 | 10-OCT-01:49 | 29.32 | 20.98 |
| November | 0.600558E+09 | 1608.40 | 05-NOV-16:05 | 24.03 | 17.90 | 92334555.27 | 70.35 | 02-NOV-20:40 | 24.03 | 17.90 |
| December | 0.324425E+09 | 979.69 | 12-DEC-14:20 | 22.80 | 16.78 | 83091239.77 | 70.33 | 13-DEC-00:10 | 17.62 | 14.70 |
| Annual Sum or Average | 0.178426E+11 | 0.125969E+10 | ||||||||
| Minimum of Months | 0.224917E+09 | 731.14 | 15.60 | 6.41 | 76908258.19 | 70.27 | 14.80 | 6.00 | ||
| Maximum of Months | 0.324975E+10 | 2521.51 | 36.32 | 23.86 | 0.129198E+09 | 70.37 | 33.22 | 22.12 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 | 4.97 | 0.106614E+09 | 106.86 | 31-JAN-21:10 | 16.82 | 12.20 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 | 7.50 | 0.118439E+09 | 133.90 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.51 | 0.181415E+09 | 159.91 | 30-MAR-20:10 | 24.32 | 16.97 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.82 | 0.215239E+09 | 159.97 | 17-APR-20:10 | 22.33 | 15.18 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 | 0.258282E+09 | 169.95 | 19-MAY-20:10 | 25.32 | 17.11 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 | 18.59 | 0.273506E+09 | 177.34 | 13-JUN-20:10 | 29.22 | 21.95 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 | 21.38 | 0.290975E+09 | 183.48 | 07-JUL-20:10 | 31.02 | 23.15 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 21.87 | 0.293107E+09 | 181.32 | 02-AUG-20:10 | 29.57 | 23.21 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 | 18.46 | 0.255611E+09 | 171.08 | 07-SEP-20:10 | 26.93 | 22.31 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 | 0.201332E+09 | 155.14 | 10-OCT-20:10 | 22.02 | 19.13 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.60 | 0.154509E+09 | 138.43 | 05-NOV-20:10 | 16.70 | 16.70 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 | 0.123431E+09 | 124.73 | 12-DEC-21:10 | 18.30 | 14.62 |
| Annual Sum or Average | 0.00 | 0.247246E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 1.80 | 1.51 | 0.106614E+09 | 106.86 | 16.70 | 11.65 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 21.87 | 0.293107E+09 | 183.48 | 31.02 | 23.21 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 | 4.97 | 77014649.16 | 86.67 | 31-JAN-22:49 | 12.98 | 10.12 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 | 7.50 | 93123871.29 | 116.36 | 28-FEB-22:49 | 17.57 | 10.18 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.51 | 0.153338E+09 | 135.47 | 30-MAR-20:10 | 24.32 | 16.97 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.82 | 0.193337E+09 | 151.88 | 17-APR-17:10 | 28.03 | 16.54 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 | 0.247632E+09 | 177.34 | 19-MAY-17:10 | 30.40 | 19.11 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 | 18.59 | 0.284976E+09 | 210.64 | 06-JUN-17:10 | 33.72 | 21.43 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 | 21.38 | 0.308397E+09 | 225.31 | 07-JUL-17:10 | 34.82 | 23.53 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 21.87 | 0.314749E+09 | 221.91 | 01-AUG-17:10 | 34.72 | 23.57 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 | 18.46 | 0.273011E+09 | 186.84 | 07-SEP-17:10 | 30.50 | 22.96 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 | 0.221879E+09 | 165.39 | 10-OCT-17:10 | 28.43 | 20.32 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.60 | 0.162453E+09 | 139.38 | 05-NOV-21:49 | 15.78 | 15.78 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 | 0.110257E+09 | 112.75 | 13-DEC-06:10 | 16.70 | 15.65 |
| Annual Sum or Average | 0.00 | 0.244017E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 1.80 | 1.51 | 77014649.16 | 86.67 | 12.98 | 10.12 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 21.87 | 0.314749E+09 | 225.31 | 34.82 | 23.57 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 | 4.97 | 0.150042E+09 | 108.75 | 31-JAN-21:10 | 16.82 | 12.20 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 | 7.50 | 0.155496E+09 | 139.24 | 28-FEB-21:10 | 20.32 | 11.65 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.51 | 0.222057E+09 | 153.43 | 30-MAR-20:10 | 24.32 | 16.97 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.82 | 0.247853E+09 | 155.96 | 17-APR-20:10 | 22.33 | 15.18 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 | 0.273716E+09 | 159.40 | 19-MAY-20:10 | 25.32 | 17.11 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 | 18.59 | 0.274649E+09 | 162.42 | 13-JUN-20:10 | 29.22 | 21.95 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 | 21.38 | 0.286555E+09 | 165.03 | 07-JUL-20:10 | 31.02 | 23.15 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 21.87 | 0.287643E+09 | 165.08 | 18-AUG-20:10 | 31.60 | 22.41 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 | 18.46 | 0.267526E+09 | 160.78 | 07-SEP-20:10 | 26.93 | 22.31 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 | 0.244169E+09 | 154.36 | 10-OCT-20:10 | 22.02 | 19.13 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.60 | 0.199970E+09 | 144.69 | 05-NOV-20:10 | 16.70 | 16.70 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 | 0.167242E+09 | 127.74 | 13-DEC-21:40 | 13.50 | 13.12 |
| Annual Sum or Average | 0.00 | 0.277692E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 1.80 | 1.51 | 0.150042E+09 | 108.75 | 13.50 | 11.65 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 21.87 | 0.287643E+09 | 165.08 | 31.60 | 23.15 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.108670E+10 | 1729.33 | 07-JAN-10:00 | -3.9 |
| February | 0.750010E+09 | 2169.74 | 12-FEB-06:00 | -12.2 |
| March | 88123690.96 | 678.53 | 22-MAR-05:00 | 6.10 |
| April | 14123214.59 | 380.88 | 06-APR-07:10 | 2.25 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 19756541.19 | 483.81 | 22-NOV-06:00 | -3.3 |
| December | 0.308707E+09 | 1070.43 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.226742E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.108670E+10 | 2169.74 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.174662E+10 | 1897.88 | 07-JAN-10:00 | -3.9 |
| February | 0.119404E+10 | 2294.08 | 12-FEB-06:00 | -12.2 |
| March | 0.233061E+09 | 832.35 | 22-MAR-05:00 | 6.10 |
| April | 39948198.29 | 454.82 | 06-APR-07:00 | 1.70 |
| May | 20967.71 | 15.42 | 02-MAY-12:30 | 23.85 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 86009795.93 | 748.37 | 22-NOV-06:00 | -3.3 |
| December | 0.682967E+09 | 1257.44 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.398266E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.174662E+10 | 2294.08 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.487277E+09 | 8783.65 | 17-JAN-07:01 | 3.12 |
| February | 0.395165E+09 | 8759.59 | 15-FEB-08:61 | 4.50 |
| March | 0.171210E+09 | 7324.49 | 22-MAR-07:01 | 5.00 |
| April | 0.235055E+09 | 1393.16 | 06-APR-07:01 | 2.25 |
| May | 0.326587E+09 | 561.58 | 18-MAY-16:12 | 29.40 |
| June | 0.435350E+09 | 697.84 | 06-JUN-16:13 | 33.90 |
| July | 0.457395E+09 | 753.83 | 07-JUL-16:13 | 35.40 |
| August | 0.431657E+09 | 744.13 | 01-AUG-16:13 | 35.00 |
| September | 0.292237E+09 | 575.32 | 07-SEP-16:13 | 31.33 |
| October | 0.114526E+09 | 518.63 | 10-OCT-16:13 | 29.63 |
| November | 62129280.99 | 7327.70 | 22-NOV-08:61 | -2.2 |
| December | 70850398.46 | 8729.26 | 22-DEC-08:61 | 5.00 |
| Annual Sum or Average | 0.347944E+10 | |||
| Minimum of Months | 62129280.99 | 518.63 | -2.2 | |
| Maximum of Months | 0.487277E+09 | 8783.65 | 35.40 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.174285E+10 | 1890.37 | 07-JAN-10:00 | -3.9 |
| February | 0.117568E+10 | 2308.39 | 12-FEB-06:00 | -12.2 |
| March | 0.225163E+09 | 844.54 | 22-MAR-05:00 | 6.10 |
| April | 37830972.93 | 444.25 | 06-APR-06:00 | 1.10 |
| May | 34741.56 | 10.75 | 01-MAY-16:40 | 23.70 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 76761250.73 | 737.52 | 22-NOV-06:00 | -3.3 |
| December | 0.657708E+09 | 1247.01 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.391603E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.174285E+10 | 2308.39 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.788345E+09 | 1047.58 | 07-JAN-10:00 | -3.9 |
| February | 0.535477E+09 | 1265.54 | 12-FEB-06:00 | -12.2 |
| March | 39750694.51 | 345.01 | 22-MAR-03:00 | 7.20 |
| April | 9456137.98 | 145.70 | 11-APR-15:00 | 27.80 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 9121340.22 | 247.04 | 22-NOV-06:00 | -3.3 |
| December | 0.172050E+09 | 554.42 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.155420E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.788345E+09 | 1265.54 | 27.80 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.788572E+09 | 1047.10 | 07-JAN-10:00 | -3.9 |
| February | 0.535162E+09 | 1266.50 | 12-FEB-06:00 | -12.2 |
| March | 40207063.47 | 345.68 | 22-MAR-03:00 | 7.20 |
| April | 9393721.23 | 145.35 | 11-APR-15:00 | 27.80 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 9100356.83 | 246.92 | 22-NOV-06:00 | -3.3 |
| December | 0.171731E+09 | 553.47 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.155417E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.788572E+09 | 1266.50 | 27.80 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.330467E+09 | 870.33 | 07-JAN-10:00 | -3.9 |
| February | 0.227826E+09 | 1135.23 | 12-FEB-06:00 | -12.2 |
| March | 3228467.87 | 130.17 | 22-MAR-05:00 | 6.10 |
| April | 580448.55 | 40.57 | 07-APR-15:00 | 24.40 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
| December | 19535888.84 | 261.25 | 26-DEC-08:13 | 3.30 |
| Annual Sum or Average | 0.581638E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.330467E+09 | 1135.23 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.439581E+09 | 981.11 | 07-JAN-10:00 | -3.9 |
| February | 0.289510E+09 | 1261.01 | 12-FEB-06:00 | -12.2 |
| March | 3368394.13 | 135.65 | 22-MAR-05:00 | 6.10 |
| April | 267599.72 | 37.74 | 07-APR-15:00 | 24.40 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
| December | 30990632.80 | 326.34 | 26-DEC-08:18 | 3.30 |
| Annual Sum or Average | 0.763717E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.439581E+09 | 1261.01 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.918095E+09 | 1964.72 | 07-JAN-10:00 | -3.9 |
| February | 0.580476E+09 | 2420.49 | 12-FEB-06:00 | -12.2 |
| March | 20946304.34 | 481.79 | 22-MAR-05:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 1153741.04 | 262.99 | 25-OCT-08:00 | 7.20 |
| November | 71435342.97 | 921.00 | 22-NOV-06:00 | -3.3 |
| December | 0.425994E+09 | 1599.11 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.201810E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.918095E+09 | 2420.49 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.147207E+10 | 2112.04 | 07-JAN-10:00 | -3.9 |
| February | 0.912630E+09 | 2559.43 | 12-FEB-06:00 | -12.2 |
| March | 59044752.31 | 736.50 | 22-MAR-05:00 | 6.10 |
| April | 405919.35 | 44.67 | 07-APR-15:00 | 24.40 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 11219030.91 | 375.26 | 26-OCT-06:00 | 2.20 |
| November | 0.181726E+09 | 1125.19 | 22-NOV-06:00 | -3.3 |
| December | 0.813553E+09 | 1756.40 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.345065E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.147207E+10 | 2559.43 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.905908E+09 | 1958.52 | 07-JAN-10:00 | -3.9 |
| February | 0.569868E+09 | 2435.96 | 12-FEB-06:00 | -12.2 |
| March | 21768801.86 | 490.45 | 22-MAR-05:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 1889896.58 | 276.31 | 25-OCT-08:00 | 7.20 |
| November | 66283331.60 | 908.31 | 22-NOV-06:00 | -3.3 |
| December | 0.415873E+09 | 1584.83 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.198159E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.905908E+09 | 2435.96 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.146395E+10 | 2106.63 | 07-JAN-10:00 | -3.9 |
| February | 0.901746E+09 | 2577.16 | 12-FEB-06:00 | -12.2 |
| March | 55824662.34 | 750.49 | 22-MAR-05:00 | 6.10 |
| April | 377334.77 | 44.01 | 07-APR-15:00 | 24.40 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 11318483.44 | 431.00 | 26-OCT-06:00 | 2.20 |
| November | 0.171060E+09 | 1109.23 | 22-NOV-06:00 | -3.3 |
| December | 0.784285E+09 | 1747.35 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.338856E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.146395E+10 | 2577.16 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.497128E+09 | 1065.40 | 07-JAN-10:00 | -3.9 |
| February | 0.323791E+09 | 1314.95 | 12-FEB-06:00 | -12.2 |
| March | 548188.91 | 55.70 | 22-MAR-05:00 | 6.10 |
| April | 525936.79 | 48.82 | 07-APR-15:00 | 24.40 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 27048942.34 | 462.00 | 22-NOV-06:00 | -3.3 |
| December | 0.190230E+09 | 814.11 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.103927E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.497128E+09 | 1314.95 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.497176E+09 | 1065.01 | 07-JAN-10:00 | -3.9 |
| February | 0.323580E+09 | 1316.34 | 12-FEB-06:00 | -12.2 |
| March | 562224.40 | 57.04 | 22-MAR-05:00 | 6.10 |
| April | 501596.03 | 48.30 | 07-APR-15:00 | 24.40 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 26976584.42 | 461.46 | 22-NOV-06:00 | -3.3 |
| December | 0.190004E+09 | 813.24 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.103880E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.497176E+09 | 1316.34 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.204503E+09 | 923.73 | 07-JAN-10:00 | -3.9 |
| February | 0.132673E+09 | 1216.73 | 12-FEB-06:00 | -12.2 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 880124.54 | 148.41 | 22-NOV-06:00 | -3.3 |
| December | 37135632.44 | 502.20 | 17-DEC-05:00 | 0.00 |
| Annual Sum or Average | 0.375192E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.204503E+09 | 1216.73 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.204918E+09 | 923.36 | 07-JAN-10:00 | -3.9 |
| February | 0.132782E+09 | 1217.69 | 12-FEB-06:00 | -12.2 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 856923.40 | 146.83 | 22-NOV-06:00 | -3.3 |
| December | 37249627.09 | 499.34 | 17-DEC-05:00 | 0.00 |
| Annual Sum or Average | 0.375806E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.204918E+09 | 1217.69 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.265450E+10 | 3350.57 | 07-JAN-10:00 | -3.9 |
| February | 0.174306E+10 | 4499.17 | 12-FEB-06:00 | -12.2 |
| March | 0.451871E+09 | 1733.79 | 18-MAR-07:10 | 2.30 |
| April | 0.134432E+09 | 1543.55 | 06-APR-06:00 | 1.10 |
| May | 8243292.96 | 386.76 | 11-MAY-06:00 | 7.80 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 13568.90 | 22.61 | 29-SEP-05:00 | 12.20 |
| October | 0.211974E+09 | 1522.47 | 25-OCT-08:00 | 7.20 |
| November | 0.729319E+09 | 2407.50 | 21-NOV-04:00 | -1.7 |
| December | 0.177000E+10 | 3022.44 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.770341E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.265450E+10 | 4499.17 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.339546E+10 | 3500.41 | 07-JAN-10:00 | -3.9 |
| February | 0.221176E+10 | 4577.81 | 12-FEB-06:00 | -12.2 |
| March | 0.607293E+09 | 1892.28 | 18-MAR-07:30 | 2.50 |
| April | 0.172023E+09 | 1621.41 | 06-APR-06:00 | 1.10 |
| May | 8282072.22 | 368.57 | 11-MAY-06:00 | 7.80 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 18411.04 | 29.46 | 29-SEP-05:00 | 12.20 |
| October | 0.299604E+09 | 1521.91 | 26-OCT-06:00 | 2.20 |
| November | 0.105080E+10 | 2523.54 | 22-NOV-06:00 | -3.3 |
| December | 0.235562E+10 | 3126.36 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.101009E+11 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.339546E+10 | 4577.81 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.263734E+10 | 3346.15 | 07-JAN-10:00 | -3.9 |
| February | 0.172101E+10 | 4500.83 | 12-FEB-06:00 | -12.2 |
| March | 0.434729E+09 | 1719.33 | 18-MAR-06:50 | 2.30 |
| April | 0.121542E+09 | 1572.25 | 06-APR-06:00 | 1.10 |
| May | 6738351.91 | 373.09 | 11-MAY-05:40 | 7.97 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 14247.15 | 23.75 | 29-SEP-05:00 | 12.20 |
| October | 0.205802E+09 | 1517.63 | 25-OCT-08:00 | 7.20 |
| November | 0.706836E+09 | 2398.31 | 21-NOV-04:00 | -1.7 |
| December | 0.173648E+10 | 3013.30 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.757049E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.263734E+10 | 4500.83 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.338263E+10 | 3495.86 | 07-JAN-10:00 | -3.9 |
| February | 0.217453E+10 | 4577.76 | 12-FEB-06:00 | -12.2 |
| March | 0.580589E+09 | 1824.79 | 18-MAR-06:50 | 2.30 |
| April | 0.153143E+09 | 1640.78 | 06-APR-06:00 | 1.10 |
| May | 7520050.42 | 399.70 | 11-MAY-05:40 | 7.97 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 19062.61 | 29.78 | 29-SEP-05:00 | 12.20 |
| October | 0.283555E+09 | 1549.17 | 26-OCT-06:00 | 2.20 |
| November | 0.101152E+10 | 2513.54 | 22-NOV-06:00 | -3.3 |
| December | 0.231941E+10 | 3117.45 | 17-DEC-04:00 | 0.60 |
| Annual Sum or Average | 0.991291E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.338263E+10 | 4577.76 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.205824E+10 | 2188.95 | 07-JAN-10:00 | -3.9 |
| February | 0.128508E+10 | 2963.28 | 12-FEB-06:00 | -12.2 |
| March | 0.259685E+09 | 1123.26 | 18-MAR-07:40 | 2.60 |
| April | 74548269.09 | 952.67 | 06-APR-06:00 | 1.10 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 95353783.18 | 914.96 | 26-OCT-06:00 | 2.20 |
| November | 0.524113E+09 | 1612.68 | 22-NOV-06:00 | -3.3 |
| December | 0.131603E+10 | 1904.59 | 02-DEC-08:00 | -2.8 |
| Annual Sum or Average | 0.561305E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.205824E+10 | 2963.28 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.205867E+10 | 2188.82 | 07-JAN-10:00 | -3.9 |
| February | 0.128459E+10 | 2964.14 | 12-FEB-06:00 | -12.2 |
| March | 0.260829E+09 | 1123.89 | 18-MAR-07:25 | 2.50 |
| April | 74608352.06 | 954.62 | 06-APR-06:00 | 1.10 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 95383776.41 | 917.66 | 26-OCT-06:00 | 2.20 |
| November | 0.524514E+09 | 1612.24 | 22-NOV-06:00 | -3.3 |
| December | 0.131548E+10 | 1903.64 | 02-DEC-08:00 | -2.8 |
| Annual Sum or Average | 0.561408E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.205867E+10 | 2964.14 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141572E+10 | 2040.20 | 07-JAN-10:00 | -3.9 |
| February | 0.892546E+09 | 2879.35 | 12-FEB-06:00 | -12.2 |
| March | 0.157751E+09 | 961.66 | 18-MAR-07:03 | 2.30 |
| April | 51212258.35 | 855.12 | 06-APR-06:00 | 1.10 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 59792366.25 | 811.66 | 25-OCT-08:00 | 7.20 |
| November | 0.288494E+09 | 1458.08 | 21-NOV-04:00 | -1.7 |
| December | 0.842071E+09 | 1767.69 | 17-DEC-04:50 | 0.10 |
| Annual Sum or Average | 0.370758E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.141572E+10 | 2879.35 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141696E+10 | 2040.07 | 07-JAN-10:00 | -3.9 |
| February | 0.892850E+09 | 2880.47 | 12-FEB-06:00 | -12.2 |
| March | 0.158394E+09 | 966.75 | 18-MAR-07:04 | 2.30 |
| April | 51393383.45 | 858.36 | 06-APR-06:00 | 1.10 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 60079020.77 | 811.81 | 25-OCT-08:00 | 7.20 |
| November | 0.288795E+09 | 1457.96 | 21-NOV-04:00 | -1.7 |
| December | 0.842577E+09 | 1767.41 | 17-DEC-04:50 | 0.10 |
| Annual Sum or Average | 0.371105E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -12.2 | |
| Maximum of Months | 0.141696E+10 | 2880.47 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1.80 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1.80 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1.80 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.844750E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 319079.66 | 0.690419E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3511953.97 | 0.409918E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9109526.09 | 0.226759E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27066734.80 | 0.129898E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103343E+09 | 50335925.32 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102088E+09 | 32522109.82 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107993E+09 | 12775346.90 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32470418.65 | 73427045.12 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6151836.42 | 0.309455E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26705.26 | 0.457129E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.703109E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392080E+09 | 0.394050E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12775346.90 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107993E+09 | 0.844750E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.842385E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1066014.94 | 0.680926E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4739198.27 | 0.387483E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10399249.19 | 0.217539E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27066744.60 | 0.128420E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103343E+09 | 50402450.91 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102088E+09 | 32520256.30 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107993E+09 | 12775339.53 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32470418.00 | 73144080.39 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6151837.35 | 0.296275E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74529.34 | 0.426894E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.690283E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.395392E+09 | 0.383905E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12775339.53 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107993E+09 | 0.842385E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.730724E+09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 207443.70 | 0.625457E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1695709.92 | 0.436582E+09 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5283111.16 | 0.262766E+09 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15048713.05 | 0.172575E+09 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 66998352.35 | 0.101972E+09 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 53542816.97 | 83584693.69 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58042767.50 | 71069513.02 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16963176.85 | 0.128115E+09 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3778850.14 | 0.362439E+09 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.480533E+09 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.660358E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221561E+09 | 0.411618E+10 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71069513.02 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 66998352.35 | 0.730724E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.842339E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 971610.80 | 0.680873E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4951586.21 | 0.385878E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10393778.81 | 0.217373E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27066756.99 | 0.128807E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103343E+09 | 50466354.08 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102089E+09 | 32518486.47 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107993E+09 | 12775321.11 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32470436.97 | 73128670.00 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6151842.73 | 0.296960E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 107055.83 | 0.426517E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.690126E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.395537E+09 | 0.383776E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12775321.11 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107993E+09 | 0.842339E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508480E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 633622.67 | 0.411836E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2850061.75 | 0.237533E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6251934.78 | 0.137908E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16325986.86 | 80522659.01 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62333841.32 | 30545627.25 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61577200.74 | 19624696.79 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138518.28 | 7705739.53 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19585348.92 | 44549304.97 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3710637.46 | 0.185259E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48367.37 | 0.263394E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.417396E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238456E+09 | 0.234476E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7705739.53 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138518.28 | 0.508480E+09 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508480E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 625493.08 | 0.411854E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2850853.44 | 0.237472E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6242782.11 | 0.137865E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16325986.89 | 80526923.70 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62333841.70 | 30546025.22 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61577201.06 | 19624696.79 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138518.61 | 7705739.24 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19585348.97 | 44548561.31 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3710637.48 | 0.185258E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49133.21 | 0.263366E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.417394E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238440E+09 | 0.234464E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7705739.24 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138518.61 | 0.508480E+09 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.511128E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 192459.71 | 0.420500E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2090807.99 | 0.258727E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5425772.49 | 0.145325E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16325981.70 | 81334822.67 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62333835.52 | 30531560.20 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61577196.72 | 19624698.72 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138517.95 | 7705745.40 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19585348.30 | 44651443.39 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3710636.75 | 0.192874E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16108.04 | 0.286278E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.430716E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.236397E+09 | 0.242940E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7705745.40 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138517.95 | 0.511128E+09 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.510651E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 192459.28 | 0.420557E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2089091.44 | 0.260140E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5410145.38 | 0.146614E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16325980.12 | 81775897.52 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62333834.06 | 30566053.87 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61577197.73 | 19624706.02 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138519.96 | 7705755.42 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19585348.43 | 44706221.07 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3710636.64 | 0.193607E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16108.02 | 0.287018E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.430598E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.236379E+09 | 0.243356E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7705755.42 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65138519.96 | 0.510651E+09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122235E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 443877.42 | 0.101480E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4911033.72 | 0.648869E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12708106.69 | 0.367176E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38615411.45 | 0.198406E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147901E+09 | 73133333.42 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146145E+09 | 47115799.41 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 18636414.29 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46342293.22 | 0.104980E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8741013.71 | 0.434271E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35014.68 | 0.650124E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101877E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560352E+09 | 0.579863E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18636414.29 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 0.122235E+10 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121435E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 671644.82 | 0.993553E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4941671.21 | 0.613217E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12783430.44 | 0.358328E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38615420.25 | 0.198011E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147901E+09 | 73190400.73 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146145E+09 | 47115225.60 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 18636403.04 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46342296.31 | 0.104432E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8741017.38 | 0.414924E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 144923.85 | 0.608823E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.996467E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560796E+09 | 0.564105E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18636403.04 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 0.121435E+10 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122231E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 443879.65 | 0.101668E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4911040.00 | 0.650411E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12708127.14 | 0.369234E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38615439.42 | 0.198796E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147901E+09 | 73204126.77 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146145E+09 | 47115170.67 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 18636385.23 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46342329.06 | 0.104963E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8741024.52 | 0.434523E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35015.02 | 0.651232E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101904E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560353E+09 | 0.580614E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18636385.23 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 0.122231E+10 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121425E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 559519.91 | 0.994738E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4943417.62 | 0.612198E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12790406.82 | 0.360582E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38615446.50 | 0.198419E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147901E+09 | 73218873.68 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146145E+09 | 47114094.18 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 18636373.45 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46342328.81 | 0.104429E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8741026.42 | 0.416430E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 209926.21 | 0.608075E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.996137E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560758E+09 | 0.564423E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18636373.45 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154509E+09 | 0.121425E+10 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733784E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 407339.61 | 0.606295E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2989111.54 | 0.381529E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7753032.78 | 0.222066E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23291866.88 | 0.120629E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89210277.38 | 44221818.85 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88151069.30 | 28419139.14 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196133.14 | 11240970.16 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27952526.04 | 64028455.98 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5272368.55 | 0.261699E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85375.35 | 0.377255E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604120E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338309E+09 | 0.345529E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11240970.16 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196133.14 | 0.733784E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733788E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 399171.35 | 0.606370E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2988341.77 | 0.381495E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7748703.17 | 0.222146E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23291866.98 | 0.120632E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89210277.91 | 44222016.95 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88151069.81 | 28419138.91 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196133.66 | 11240969.75 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27952526.07 | 64026605.29 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5272368.57 | 0.261716E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87141.43 | 0.377201E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604117E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338298E+09 | 0.345537E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11240969.75 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196133.66 | 0.733788E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.743738E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 267738.28 | 0.624237E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2962216.03 | 0.407733E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7665231.06 | 0.227978E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23291862.04 | 0.120788E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89210271.22 | 44211395.90 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88151066.44 | 28419140.51 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196135.82 | 11240976.51 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27952524.91 | 64259158.59 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5272367.26 | 0.273642E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21120.06 | 0.409954E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.627235E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337991E+09 | 0.358343E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11240976.51 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196135.82 | 0.743738E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.743760E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 267738.29 | 0.624306E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2962216.09 | 0.407744E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7665231.13 | 0.228042E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23291862.30 | 0.120790E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89210271.77 | 44211920.19 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88151066.88 | 28419140.71 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196136.32 | 11240975.95 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27952525.15 | 64258059.02 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5272367.35 | 0.273602E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21120.06 | 0.409990E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.627293E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337991E+09 | 0.358366E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11240975.95 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93196136.32 | 0.743760E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161766E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 548397.90 | 0.132651E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6329132.48 | 0.806332E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16403632.68 | 0.442977E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50337439.66 | 0.242222E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194030E+09 | 92974360.46 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191832E+09 | 62539528.76 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 25305161.63 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60457769.52 | 0.126462E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11303432.36 | 0.522519E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37674.57 | 0.820398E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133906E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733854E+09 | 0.742496E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25305161.63 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 0.161766E+10 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160894E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 630847.59 | 0.130883E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6329140.25 | 0.776655E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16403671.26 | 0.432490E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50337443.51 | 0.241355E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194030E+09 | 93389192.25 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191832E+09 | 62458519.70 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 25302033.91 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60457762.91 | 0.124493E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11305013.61 | 0.499625E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50009.92 | 0.787685E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131833E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733950E+09 | 0.727956E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25302033.91 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 0.160894E+10 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161707E+10 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 548403.26 | 0.132846E+10 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6329144.25 | 0.807259E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16403675.34 | 0.445900E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50337495.98 | 0.243803E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194030E+09 | 93964910.84 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191832E+09 | 62484815.07 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 25306600.24 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60457842.33 | 0.126842E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11303453.52 | 0.525383E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37675.43 | 0.821540E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133884E+10 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733855E+09 | 0.743686E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25306600.24 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 0.161707E+10 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160859E+10 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 548424.37 | 0.130892E+10 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6329152.90 | 0.773060E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16403704.86 | 0.434917E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50337495.02 | 0.242961E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194030E+09 | 94259052.49 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191832E+09 | 62403453.89 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 25303288.08 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60457824.79 | 0.125067E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11303451.43 | 0.501978E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 115095.86 | 0.784819E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131791E+10 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.733932E+09 | 0.728019E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25303288.08 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202575E+09 | 0.160859E+10 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.971272E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 370867.29 | 0.790706E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3817596.01 | 0.471077E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9897795.34 | 0.266846E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30362303.06 | 0.150573E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117034E+09 | 57517238.64 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115708E+09 | 38036700.51 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 15296394.34 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36466627.30 | 78533433.47 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6817957.78 | 0.306840E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82459.30 | 0.477095E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.796057E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442746E+09 | 0.441985E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15296394.34 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 0.971272E+09 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.971265E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 358654.28 | 0.790741E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3817587.56 | 0.470965E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9896611.55 | 0.266906E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30362303.65 | 0.150581E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117034E+09 | 57533176.34 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115708E+09 | 38034601.18 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 15295968.27 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36466627.99 | 78526920.38 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6817957.82 | 0.306944E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85218.27 | 0.476999E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.796048E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442735E+09 | 0.441984E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15295968.27 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 0.971265E+09 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.978992E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 330784.61 | 0.806043E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3817579.27 | 0.495662E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9894291.79 | 0.275455E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30362299.21 | 0.151068E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117034E+09 | 57280544.32 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115708E+09 | 38064289.60 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 15298849.35 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36466631.18 | 79658231.48 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6817955.91 | 0.325033E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22724.77 | 0.504611E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.814084E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442642E+09 | 0.454125E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15298849.35 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 0.978992E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.979018E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 330784.68 | 0.806161E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3817579.56 | 0.495703E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9894292.63 | 0.275529E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30362299.88 | 0.151070E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117034E+09 | 57296481.50 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115708E+09 | 38062248.24 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 15298432.76 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36466632.30 | 79648575.71 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6817956.41 | 0.325078E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22724.78 | 0.504656E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.814148E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442642E+09 | 0.454167E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15298432.76 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122188E+09 | 0.979018E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.264512E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72971.83 | 0.221580E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 281393.14 | 0.147312E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 879872.79 | 88464164.79 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2984352.69 | 55818290.35 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17605134.18 | 26501410.12 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17625366.53 | 19487276.23 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17254048.50 | 12882152.25 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4047232.78 | 32186423.92 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 586529.93 | 0.100030E+09 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51422.07 | 0.142608E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221902E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61388324.45 | 0.133328E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12882152.25 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17625366.53 | 0.264512E+09 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345344E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2525242.70 | 0.244524E+10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17471332.81 | 0.172485E+10 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58175771.38 | 0.119293E+10 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101384E+09 | 0.784374E+09 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336063E+09 | 0.413245E+09 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.423708E+09 | 0.358713E+09 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372365E+09 | 0.266293E+09 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 92224757.39 | 0.670610E+09 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12112723.95 | 0.168501E+10 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 116571.98 | 0.217489E+10 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.284000E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141615E+10 | 0.180096E+11 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266293E+09 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.423708E+09 | 0.345344E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219866E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12646.60 | 0.186220E+09 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 229105.26 | 0.128085E+09 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 640345.56 | 77531818.56 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2694827.79 | 46569625.00 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15282993.34 | 21396130.00 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15472151.67 | 15236231.77 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15426479.44 | 9892945.53 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3565115.02 | 27394756.25 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 451154.46 | 90006664.45 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4820.62 | 0.124214E+09 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187568E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53779639.76 | 0.113398E+10 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9892945.53 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15472151.67 | 0.219866E+09 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1126.61 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.27 | 28-FEB-15:00 | 1243.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 100.94 | 30-MAR-16:00 | 678.71 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.76 | 04-APR-15:00 | 615.93 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.10 | 19-MAY-13:00 | 274.08 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 330.85 | 06-JUN-14:00 | 225.13 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.02 | 22-JUL-14:00 | 140.76 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.40 | 07-AUG-15:00 | 80.47 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.69 | 06-SEP-12:00 | 202.96 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.84 | 11-OCT-14:00 | 598.97 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.22 | 19-NOV-15:00 | 652.86 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1121.85 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 330.85 | 1243.08 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1126.61 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.89 | 28-FEB-15:00 | 1243.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.53 | 11-MAR-16:00 | 678.71 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.98 | 07-APR-15:00 | 615.93 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.10 | 19-MAY-13:00 | 271.46 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 330.85 | 06-JUN-14:00 | 227.29 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.02 | 22-JUL-14:00 | 140.76 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.40 | 07-AUG-15:00 | 80.47 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.69 | 06-SEP-12:00 | 202.31 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.84 | 11-OCT-14:00 | 594.85 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.94 | 19-NOV-15:00 | 634.59 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1121.85 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 330.85 | 1243.08 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 876.56 | 07-JAN-10:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 40.27 | 28-FEB-15:00 | 1023.24 | 12-FEB-01:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 100.92 | 30-MAR-16:00 | 601.92 | 22-MAR-03:00 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.76 | 04-APR-15:00 | 682.74 | 05-APR-11:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.08 | 19-MAY-13:00 | 312.61 | 10-MAY-08:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 330.81 | 06-JUN-14:00 | 266.00 | 07-JUN-07:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 200.98 | 10-JUL-15:00 | 197.29 | 28-JUL-17:50 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.37 | 07-AUG-15:00 | 156.72 | 07-AUG-21:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.66 | 06-SEP-12:00 | 247.16 | 28-SEP-18:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.81 | 11-OCT-14:00 | 658.01 | 25-OCT-10:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 691.99 | 20-NOV-09:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 984.29 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.72 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 330.81 | 1023.24 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1126.61 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.37 | 28-FEB-15:00 | 1243.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.15 | 11-MAR-16:00 | 678.71 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.88 | 07-APR-15:00 | 615.93 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.10 | 19-MAY-13:00 | 275.59 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 330.85 | 06-JUN-14:00 | 228.61 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.02 | 22-JUL-14:00 | 140.76 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.40 | 07-AUG-15:00 | 80.47 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.69 | 06-SEP-12:00 | 201.84 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.84 | 11-OCT-14:00 | 594.85 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.53 | 19-NOV-15:00 | 634.59 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1121.85 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.47 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 330.85 | 1243.08 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 679.54 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.20 | 28-FEB-15:00 | 749.79 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.52 | 11-MAR-16:00 | 409.38 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.57 | 07-APR-15:00 | 384.77 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.69 | 19-MAY-13:00 | 172.81 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 06-JUN-14:00 | 137.89 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.04 | 22-JUL-14:00 | 84.90 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.34 | 07-AUG-15:00 | 48.54 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.29 | 06-SEP-12:00 | 125.80 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 | 11-OCT-14:00 | 381.97 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.21 | 19-NOV-15:00 | 389.08 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 676.67 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 749.79 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 679.54 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.90 | 28-FEB-15:00 | 749.79 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.63 | 11-MAR-16:00 | 409.38 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.42 | 07-APR-15:00 | 384.75 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.69 | 19-MAY-13:00 | 172.91 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 06-JUN-14:00 | 137.89 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.04 | 22-JUL-14:00 | 84.90 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.34 | 07-AUG-15:00 | 48.54 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.29 | 06-SEP-12:00 | 125.80 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 | 11-OCT-14:00 | 381.84 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.32 | 19-NOV-15:00 | 388.88 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 676.67 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 749.79 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 679.54 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.29 | 28-FEB-15:00 | 749.79 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.89 | 30-MAR-16:00 | 409.38 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.70 | 04-APR-15:00 | 392.95 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.69 | 19-MAY-13:00 | 173.85 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 06-JUN-14:00 | 137.89 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.04 | 22-JUL-14:00 | 84.90 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.34 | 07-AUG-15:00 | 48.54 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.29 | 06-SEP-12:00 | 126.15 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 | 11-OCT-14:00 | 387.68 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.37 | 19-NOV-15:00 | 415.56 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 676.67 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 749.79 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 679.54 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.29 | 28-FEB-15:00 | 749.79 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.89 | 30-MAR-16:00 | 409.38 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.70 | 04-APR-15:00 | 396.49 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.69 | 19-MAY-13:00 | 175.36 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 06-JUN-14:00 | 137.89 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.04 | 22-JUL-14:00 | 84.90 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.34 | 07-AUG-15:00 | 48.54 | 25-AUG-05:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.29 | 06-SEP-12:00 | 127.17 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 | 11-OCT-14:00 | 390.29 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.37 | 19-NOV-15:00 | 416.76 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 676.67 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.56 | 749.79 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1620.32 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.72 | 28-FEB-15:00 | 1787.55 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.30 | 30-MAR-16:00 | 976.76 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.52 | 04-APR-15:00 | 953.37 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 196.37 | 19-MAY-13:00 | 409.73 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 06-JUN-14:00 | 328.50 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 375.57 | 22-JUL-14:00 | 203.07 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 404.91 | 07-AUG-15:00 | 116.11 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.48 | 06-SEP-12:00 | 285.78 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.14 | 11-OCT-14:00 | 856.06 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.69 | 19-NOV-15:00 | 915.34 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1613.74 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.11 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 1787.55 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1620.32 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.72 | 28-FEB-15:00 | 1787.55 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.30 | 30-MAR-16:00 | 976.76 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.52 | 04-APR-15:00 | 940.29 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 196.37 | 19-MAY-13:00 | 408.71 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 06-JUN-14:00 | 329.20 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 375.57 | 22-JUL-14:00 | 203.07 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 404.91 | 07-AUG-15:00 | 116.11 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.48 | 06-SEP-12:00 | 285.14 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.14 | 11-OCT-14:00 | 856.06 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.17 | 19-NOV-15:00 | 913.12 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1613.74 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.11 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 1787.55 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1620.32 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.72 | 28-FEB-15:00 | 1787.55 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.30 | 30-MAR-16:00 | 976.76 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.52 | 04-APR-15:00 | 976.03 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 196.37 | 19-MAY-13:00 | 419.10 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 06-JUN-14:00 | 329.20 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 375.57 | 22-JUL-14:00 | 203.07 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 404.91 | 07-AUG-15:00 | 116.11 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.48 | 06-SEP-12:00 | 285.14 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.14 | 11-OCT-14:00 | 856.06 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.69 | 19-NOV-15:00 | 915.57 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1613.74 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.11 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 1787.55 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1620.32 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.72 | 28-FEB-15:00 | 1787.55 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.30 | 30-MAR-16:00 | 976.76 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.52 | 04-APR-15:00 | 962.80 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 196.37 | 19-MAY-13:00 | 418.74 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 06-JUN-14:00 | 329.20 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 375.57 | 22-JUL-14:00 | 203.07 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 404.91 | 07-AUG-15:00 | 116.11 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 214.48 | 06-SEP-12:00 | 284.50 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.14 | 11-OCT-14:00 | 856.06 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.82 | 19-NOV-15:00 | 913.12 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1613.74 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.11 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 474.50 | 1787.55 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 977.33 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.21 | 28-FEB-15:00 | 1078.21 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 30-MAR-16:00 | 589.15 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.86 | 04-APR-15:00 | 602.64 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.44 | 19-MAY-13:00 | 258.64 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 06-JUN-14:00 | 198.57 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 226.54 | 22-JUL-14:00 | 122.48 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 244.23 | 07-AUG-15:00 | 70.04 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.37 | 06-SEP-12:00 | 178.21 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.85 | 11-OCT-14:00 | 529.08 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.71 | 19-NOV-15:00 | 559.60 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 973.37 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.04 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 1078.21 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 977.33 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.21 | 28-FEB-15:00 | 1078.21 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 30-MAR-16:00 | 589.15 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.86 | 04-APR-15:00 | 603.11 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.44 | 19-MAY-13:00 | 258.67 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 06-JUN-14:00 | 198.57 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 226.54 | 22-JUL-14:00 | 122.48 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 244.23 | 07-AUG-15:00 | 70.04 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.37 | 06-SEP-12:00 | 178.21 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.85 | 11-OCT-14:00 | 528.87 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.96 | 19-NOV-15:00 | 559.18 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 973.37 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.04 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 1078.21 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 977.33 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.21 | 28-FEB-15:00 | 1078.21 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 30-MAR-16:00 | 597.22 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.86 | 04-APR-15:00 | 610.73 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.44 | 19-MAY-13:00 | 258.86 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 06-JUN-14:00 | 198.57 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 226.54 | 22-JUL-14:00 | 122.48 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 244.23 | 07-AUG-15:00 | 70.04 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.37 | 06-SEP-12:00 | 178.40 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.85 | 11-OCT-14:00 | 534.22 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.07 | 19-NOV-15:00 | 590.50 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 973.37 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.04 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 1078.21 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 977.33 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.21 | 28-FEB-15:00 | 1078.21 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.04 | 30-MAR-16:00 | 597.21 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.86 | 04-APR-15:00 | 611.22 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.44 | 19-MAY-13:00 | 258.90 | 10-MAY-08:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 06-JUN-14:00 | 198.57 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 226.54 | 22-JUL-14:00 | 122.48 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 244.23 | 07-AUG-15:00 | 70.04 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.37 | 06-SEP-12:00 | 178.40 | 29-SEP-05:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.85 | 11-OCT-14:00 | 534.02 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.07 | 19-NOV-15:00 | 590.38 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 973.37 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.04 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 286.21 | 1078.21 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2146.76 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.99 | 28-FEB-15:00 | 2367.60 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.88 | 30-MAR-16:00 | 1295.73 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.66 | 04-APR-15:00 | 1176.08 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 258.03 | 19-MAY-13:00 | 476.03 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 06-JUN-14:00 | 370.89 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 494.24 | 22-JUL-14:00 | 270.69 | 28-JUL-17:30 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 533.20 | 07-AUG-15:00 | 154.48 | 25-AUG-05:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.00 | 06-SEP-12:00 | 344.14 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.40 | 11-OCT-14:00 | 1135.62 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.77 | 19-NOV-15:00 | 1210.96 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2138.79 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.48 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 2367.60 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2146.76 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.99 | 28-FEB-15:00 | 2367.60 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.88 | 30-MAR-16:00 | 1295.73 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.66 | 04-APR-15:00 | 1176.08 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 258.03 | 19-MAY-13:00 | 476.03 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 06-JUN-14:00 | 378.71 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 494.24 | 22-JUL-14:00 | 270.69 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 533.20 | 07-AUG-15:00 | 154.48 | 25-AUG-05:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.00 | 06-SEP-12:00 | 342.97 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.40 | 11-OCT-14:00 | 1135.62 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.81 | 19-NOV-15:00 | 1210.96 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2138.79 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.48 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 2367.60 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2146.76 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.99 | 28-FEB-15:00 | 2367.60 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.88 | 30-MAR-16:00 | 1295.73 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.66 | 04-APR-15:00 | 1176.08 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 258.03 | 19-MAY-13:00 | 476.03 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 06-JUN-14:00 | 393.74 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 494.24 | 22-JUL-14:00 | 270.69 | 28-JUL-17:30 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 533.20 | 07-AUG-15:00 | 154.48 | 25-AUG-05:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.00 | 06-SEP-12:00 | 342.67 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.40 | 11-OCT-14:00 | 1135.62 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.78 | 19-NOV-15:00 | 1210.96 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2138.79 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.48 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 2367.60 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2146.76 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.99 | 28-FEB-15:00 | 2367.60 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 188.88 | 30-MAR-16:00 | 1295.73 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.66 | 04-APR-15:00 | 1176.08 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 258.03 | 19-MAY-13:00 | 476.03 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 06-JUN-14:00 | 401.72 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 494.24 | 22-JUL-14:00 | 270.69 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 533.20 | 07-AUG-15:00 | 154.68 | 25-AUG-05:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 282.00 | 06-SEP-12:00 | 341.50 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.40 | 11-OCT-14:00 | 1135.62 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.09 | 19-NOV-15:00 | 1210.96 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2138.79 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.68 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 625.14 | 2367.60 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1294.87 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.42 | 28-FEB-15:00 | 1428.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.93 | 30-MAR-16:00 | 781.55 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.64 | 04-APR-15:00 | 709.38 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.64 | 19-MAY-13:00 | 287.13 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 06-JUN-14:00 | 246.70 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 298.11 | 22-JUL-14:00 | 163.28 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 321.61 | 07-AUG-15:00 | 93.18 | 25-AUG-05:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.09 | 06-SEP-12:00 | 217.79 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.11 | 11-OCT-14:00 | 684.98 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.49 | 19-NOV-15:00 | 730.42 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1290.06 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.18 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 1428.08 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1294.87 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.42 | 28-FEB-15:00 | 1428.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.93 | 30-MAR-16:00 | 781.55 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.64 | 04-APR-15:00 | 709.38 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.64 | 19-MAY-13:00 | 287.13 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 06-JUN-14:00 | 246.95 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 298.11 | 22-JUL-14:00 | 163.28 | 28-JUL-17:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 321.61 | 07-AUG-15:00 | 93.18 | 25-AUG-05:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.09 | 06-SEP-12:00 | 217.76 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.11 | 11-OCT-14:00 | 684.98 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.89 | 19-NOV-15:00 | 730.42 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1290.06 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.18 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 1428.08 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1294.87 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.42 | 28-FEB-15:00 | 1428.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.93 | 30-MAR-16:00 | 781.55 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.64 | 04-APR-15:00 | 709.38 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.64 | 19-MAY-13:00 | 287.13 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 06-JUN-14:00 | 241.62 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 298.11 | 22-JUL-14:00 | 163.28 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 321.61 | 07-AUG-15:00 | 93.21 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.09 | 06-SEP-12:00 | 218.50 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.11 | 11-OCT-14:00 | 684.98 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.93 | 19-NOV-15:00 | 730.42 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1290.06 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.21 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 1428.08 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1294.87 | 07-JAN-10:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.42 | 28-FEB-15:00 | 1428.08 | 12-FEB-01:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.93 | 30-MAR-16:00 | 781.55 | 22-MAR-03:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.64 | 04-APR-15:00 | 709.38 | 05-APR-11:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.64 | 19-MAY-13:00 | 287.13 | 10-MAY-04:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 06-JUN-14:00 | 241.88 | 07-JUN-07:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 298.11 | 22-JUL-14:00 | 163.28 | 28-JUL-17:40 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 321.61 | 07-AUG-15:00 | 93.19 | 25-AUG-05:05 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.09 | 06-SEP-12:00 | 218.47 | 28-SEP-18:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.11 | 11-OCT-14:00 | 684.98 | 25-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.93 | 19-NOV-15:00 | 730.42 | 20-NOV-09:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1290.06 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.19 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 377.07 | 1428.08 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 334.59 | 07-JAN-10:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.61 | 28-FEB-14:00 | 374.26 | 12-FEB-01:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.98 | 11-MAR-16:00 | 218.35 | 22-MAR-03:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.90 | 12-APR-14:00 | 218.41 | 05-APR-11:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.71 | 19-MAY-13:00 | 91.68 | 10-MAY-04:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.98 | 06-JUN-14:00 | 78.63 | 07-JUN-07:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.12 | 22-JUL-14:00 | 61.36 | 28-JUL-18:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.93 | 07-AUG-15:00 | 35.35 | 07-AUG-21:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.37 | 06-SEP-12:00 | 75.05 | 28-SEP-18:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.38 | 10-OCT-16:00 | 188.07 | 25-OCT-08:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.25 | 19-NOV-15:00 | 213.62 | 20-NOV-09:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 343.85 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.35 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.98 | 374.26 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 15029.46 | 14-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.21 | 26-FEB-15:00 | 18633.03 | 12-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1209.24 | 30-MAR-16:03 | 10731.62 | 19-MAR-06:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1453.19 | 17-APR-16:03 | 11413.55 | 06-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1956.32 | 19-MAY-16:03 | 8447.83 | 11-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3267.51 | 06-JUN-16:02 | 6950.64 | 08-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4145.19 | 08-JUL-16:01 | 3847.30 | 29-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3759.78 | 01-AUG-16:02 | 3860.04 | 25-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2047.53 | 07-SEP-16:02 | 6997.77 | 14-SEP-06:01 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1586.75 | 10-OCT-16:02 | 11274.82 | 26-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.81 | 19-NOV-15:00 | 13755.83 | 21-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 14448.87 | 18-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3847.30 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 4145.19 | 18633.03 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 276.96 | 07-JAN-10:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.60 | 26-FEB-15:00 | 309.20 | 12-FEB-01:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.42 | 30-MAR-16:00 | 188.79 | 22-MAR-03:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.40 | 12-APR-14:00 | 193.34 | 05-APR-11:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.19 | 19-MAY-13:00 | 83.80 | 10-MAY-08:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.50 | 06-JUN-14:00 | 67.44 | 07-JUN-07:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.03 | 22-JUL-14:00 | 47.02 | 28-JUL-18:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.66 | 07-AUG-15:00 | 27.88 | 25-AUG-05:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.02 | 06-SEP-12:00 | 60.47 | 28-SEP-18:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.96 | 10-OCT-16:00 | 169.21 | 25-OCT-08:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.27 | 19-NOV-15:00 | 182.50 | 20-NOV-09:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 289.02 | 17-DEC-04:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.88 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.50 | 309.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 463.53 | 15-JAN-14:10 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.29 |
| February | 588.26 | 26-FEB-17:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.18 |
| March | 986.98 | 30-MAR-16:17 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 89.17 | 0.00 |
| April | 1100.56 | 17-APR-16:15 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 32.94 | 0.00 |
| May | 1455.74 | 19-MAY-17:30 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.50 | 0.00 |
| June | 1889.24 | 06-JUN-17:13 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 274.25 | 0.00 |
| July | 1999.48 | 08-JUL-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 87.40 | 0.00 |
| August | 2201.08 | 18-AUG-17:17 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 157.89 | 0.00 |
| September | 2081.42 | 07-SEP-16:02 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 98.58 | 0.00 |
| October | 2050.96 | 10-OCT-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 75.02 | 0.00 |
| November | 1330.94 | 05-NOV-16:05 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 | 0.00 |
| December | 554.82 | 17-DEC-17:25 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 401.30 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 463.53 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2201.08 | 950.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 274.25 | 401.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 271.55 | 31-JAN-23:30 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.72 |
| February | 298.86 | 20-FEB-21:40 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 203.83 |
| March | 631.12 | 30-MAR-16:40 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 77.84 | 0.00 |
| April | 817.94 | 17-APR-17:20 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 13.94 | 0.00 |
| May | 1359.36 | 19-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.50 | 0.00 |
| June | 1879.72 | 06-JUN-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 266.43 | 0.00 |
| July | 1922.64 | 21-JUL-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 138.75 | 0.00 |
| August | 2024.05 | 18-AUG-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 159.72 | 0.00 |
| September | 1769.82 | 07-SEP-17:07 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 83.54 | 0.00 |
| October | 1317.42 | 10-OCT-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 67.04 | 0.00 |
| November | 743.41 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 | 0.00 |
| December | 412.90 | 14-DEC-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.12 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 271.55 | 123.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2024.05 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 266.43 | 215.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 947.79 | 27-JAN-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 463.38 |
| February | 1018.50 | 03-FEB-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 666.47 |
| March | 4474.51 | 31-MAR-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.00 |
| April | 5881.06 | 17-APR-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.09 |
| May | 5419.44 | 17-MAY-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.16 |
| June | 5747.53 | 08-JUN-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.66 |
| July | 5050.74 | 25-JUL-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92.85 |
| August | 4573.95 | 25-AUG-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.96 |
| September | 5684.23 | 14-SEP-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.43 |
| October | 6057.67 | 12-OCT-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 224.38 |
| November | 3569.21 | 06-NOV-09:03 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196.81 |
| December | 2555.13 | 13-DEC-09:03 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106.05 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 947.79 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.96 | |
| Maximum of Months | 6057.67 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 666.47 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 271.58 | 31-JAN-23:30 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.74 |
| February | 298.44 | 20-FEB-21:40 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 203.57 |
| March | 395.95 | 30-MAR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 95.00 | 0.00 |
| April | 622.21 | 19-APR-16:27 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 46.47 | 0.00 |
| May | 1070.57 | 19-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 103.39 | 0.00 |
| June | 1647.27 | 06-JUN-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 282.16 | 0.00 |
| July | 1734.92 | 08-JUL-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 78.98 | 0.00 |
| August | 1772.08 | 19-AUG-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 146.87 | 0.00 |
| September | 1569.13 | 07-SEP-16:08 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 98.58 | 0.00 |
| October | 1104.29 | 10-OCT-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 75.02 | 0.00 |
| November | 573.73 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 | 0.00 |
| December | 413.48 | 14-DEC-21:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.32 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 271.58 | 206.62 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1772.08 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 282.16 | 215.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 278.99 | 20-JAN-22:15 | 475.00 | 104.17 | 835.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.49 |
| February | 324.48 | 27-FEB-06:10 | 712.50 | 182.27 | 953.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.52 |
| March | 452.66 | 13-MAR-07:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.04 |
| April | 601.06 | 19-APR-16:27 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 28.03 | 0.00 |
| May | 920.90 | 19-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 62.36 | 0.00 |
| June | 1303.62 | 06-JUN-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 160.71 | 0.00 |
| July | 1386.48 | 08-JUL-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 47.64 | 0.00 |
| August | 1387.25 | 19-AUG-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.59 | 0.00 |
| September | 1238.59 | 07-SEP-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 48.45 | 0.00 |
| October | 908.86 | 10-OCT-17:10 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 29.72 | 0.00 |
| November | 581.35 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 0.00 |
| December | 462.45 | 14-DEC-08:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 278.99 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1387.25 | 712.50 | 351.55 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 160.71 | 156.51 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 276.20 | 20-JAN-22:05 | 475.00 | 104.17 | 835.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.67 |
| February | 329.96 | 27-FEB-06:20 | 712.50 | 182.27 | 953.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.23 |
| March | 452.26 | 13-MAR-07:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.99 |
| April | 601.90 | 19-APR-16:27 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 28.03 | 0.00 |
| May | 918.20 | 19-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 62.36 | 0.00 |
| June | 1301.32 | 06-JUN-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 160.71 | 0.00 |
| July | 1384.98 | 08-JUL-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 47.64 | 0.00 |
| August | 1386.35 | 19-AUG-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.59 | 0.00 |
| September | 1235.95 | 07-SEP-17:17 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 48.45 | 0.00 |
| October | 909.55 | 18-OCT-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 18.46 | 0.00 |
| November | 577.43 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 0.00 |
| December | 462.42 | 14-DEC-08:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 276.20 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1386.35 | 712.50 | 351.55 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 160.71 | 156.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 544.99 | 15-JAN-12:30 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.92 |
| February | 532.63 | 28-FEB-17:05 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.03 |
| March | 724.17 | 30-MAR-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 57.30 | 0.00 |
| April | 859.53 | 17-APR-16:10 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 21.35 | 0.00 |
| May | 1027.27 | 20-MAY-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.90 | 0.00 |
| June | 1319.37 | 25-JUN-16:50 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 112.55 | 0.00 |
| July | 1456.40 | 08-JUL-17:05 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 47.63 | 0.00 |
| August | 1598.55 | 19-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.59 | 0.00 |
| September | 1598.17 | 23-SEP-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 57.93 | 0.00 |
| October | 1631.40 | 10-OCT-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 45.25 | 0.00 |
| November | 1152.97 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 0.00 |
| December | 616.40 | 17-DEC-18:50 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 291.54 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 532.63 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1631.40 | 950.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 112.55 | 291.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 524.37 | 27-JAN-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.49 |
| February | 559.18 | 28-FEB-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 3.04 | 0.00 |
| March | 757.90 | 30-MAR-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 57.30 | 0.00 |
| April | 913.07 | 17-APR-16:05 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 21.35 | 0.00 |
| May | 1106.92 | 20-MAY-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.90 | 0.00 |
| June | 1444.17 | 25-JUN-17:00 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 109.92 | 0.00 |
| July | 1587.19 | 08-JUL-17:20 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 47.64 | 0.00 |
| August | 1733.42 | 19-AUG-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.59 | 0.00 |
| September | 1697.49 | 23-SEP-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 57.93 | 0.00 |
| October | 1696.30 | 10-OCT-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 45.25 | 0.00 |
| November | 1197.30 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 0.00 |
| December | 612.23 | 17-DEC-18:35 | 475.00 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 285.15 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 524.37 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1733.42 | 950.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 109.92 | 285.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 552.17 | 14-JAN-17:35 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 284.08 |
| February | 1418.40 | 26-FEB-16:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 3.43 | 0.00 |
| March | 2076.63 | 30-MAR-16:15 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 127.41 | 0.00 |
| April | 2034.64 | 15-APR-16:10 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 82.07 | 0.00 |
| May | 2170.98 | 19-MAY-17:30 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 131.06 | 0.00 |
| June | 2443.87 | 06-JUN-17:20 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 393.30 | 0.00 |
| July | 2384.03 | 08-JUL-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 125.38 | 0.00 |
| August | 2541.30 | 18-AUG-17:17 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 226.47 | 0.00 |
| September | 2453.58 | 23-SEP-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 137.44 | 0.00 |
| October | 2356.74 | 10-OCT-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 107.44 | 0.00 |
| November | 1642.42 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 | 0.00 |
| December | 817.47 | 12-DEC-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 552.17 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2541.30 | 950.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 393.30 | 284.08 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 311.96 | 31-JAN-24:00 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 376.75 |
| February | 578.69 | 28-FEB-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.82 |
| March | 1662.98 | 30-MAR-16:40 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 111.13 | 0.00 |
| April | 1696.24 | 17-APR-17:15 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 19.92 | 0.00 |
| May | 2063.23 | 19-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 131.06 | 0.00 |
| June | 2430.76 | 06-JUN-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 382.07 | 0.00 |
| July | 2338.45 | 21-JUL-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 198.97 | 0.00 |
| August | 2423.21 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 354.06 | 0.00 |
| September | 1975.88 | 07-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 134.54 | 0.00 |
| October | 1531.78 | 10-OCT-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.99 | 0.00 |
| November | 949.04 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 | 0.00 |
| December | 449.51 | 14-DEC-07:35 | 403.75 | 112.83 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 363.22 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 311.96 | 123.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2430.76 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 382.07 | 376.75 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 581.15 | 15-JAN-11:40 | 118.75 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 342.27 |
| February | 1228.81 | 26-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 20.64 | 0.00 |
| March | 1725.36 | 30-MAR-16:10 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 135.78 | 0.00 |
| April | 1748.34 | 16-APR-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 67.27 | 0.00 |
| May | 1790.21 | 19-MAY-16:08 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 168.35 | 0.00 |
| June | 2113.44 | 06-JUN-17:05 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 404.66 | 0.00 |
| July | 2133.14 | 08-JUL-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 133.43 | 0.00 |
| August | 2276.19 | 19-AUG-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 267.12 | 0.00 |
| September | 2133.65 | 23-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 148.29 | 0.00 |
| October | 2095.26 | 10-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 98.44 | 0.00 |
| November | 1379.72 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 | 0.00 |
| December | 778.55 | 12-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.53 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 581.15 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2276.19 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 404.66 | 342.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 312.56 | 31-JAN-24:00 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 377.43 |
| February | 475.47 | 28-FEB-17:05 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.82 |
| March | 1296.06 | 30-MAR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 135.78 | 0.00 |
| April | 1324.73 | 16-APR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 32.42 | 0.00 |
| May | 1631.30 | 30-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 116.03 | 0.00 |
| June | 2094.57 | 06-JUN-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 404.66 | 0.00 |
| July | 2004.82 | 08-JUL-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 310.64 | 0.00 |
| August | 2114.44 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 354.06 | 0.00 |
| September | 1697.00 | 07-SEP-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 141.29 | 0.00 |
| October | 1237.39 | 10-OCT-16:08 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 107.44 | 0.00 |
| November | 712.59 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 | 0.00 |
| December | 455.89 | 14-DEC-08:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 368.53 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 312.56 | 71.25 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2114.44 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 404.66 | 377.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 376.33 | 21-JAN-02:20 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 252.53 |
| February | 486.76 | 23-FEB-08:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.49 |
| March | 1068.22 | 30-MAR-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 76.85 | 0.00 |
| April | 1095.35 | 19-APR-16:27 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 39.94 | 0.00 |
| May | 1296.78 | 19-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 89.29 | 0.00 |
| June | 1580.49 | 06-JUN-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 230.46 | 0.00 |
| July | 1549.02 | 15-JUL-17:08 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 142.31 | 0.00 |
| August | 1565.93 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 213.56 | 0.00 |
| September | 1297.28 | 07-SEP-16:20 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 83.19 | 0.00 |
| October | 1011.10 | 10-OCT-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 61.31 | 0.00 |
| November | 744.78 | 05-NOV-16:05 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 | 0.00 |
| December | 490.41 | 15-DEC-04:00 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 363.80 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 376.33 | 123.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1580.49 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 230.46 | 363.80 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 374.81 | 21-JAN-02:70 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 240.39 |
| February | 487.00 | 23-FEB-08:00 | 201.88 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.60 |
| March | 1063.54 | 30-MAR-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 76.85 | 0.00 |
| April | 1094.32 | 19-APR-16:27 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 39.94 | 0.00 |
| May | 1291.44 | 19-MAY-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 89.29 | 0.00 |
| June | 1576.99 | 06-JUN-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 230.46 | 0.00 |
| July | 1547.36 | 08-JUL-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 187.37 | 0.00 |
| August | 1563.84 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 213.56 | 0.00 |
| September | 1296.15 | 07-SEP-16:20 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 83.19 | 0.00 |
| October | 1008.99 | 10-OCT-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 61.31 | 0.00 |
| November | 740.49 | 05-NOV-16:05 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 | 0.00 |
| December | 490.51 | 15-DEC-04:00 | 237.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 363.87 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 374.81 | 123.50 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1576.99 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 230.46 | 363.87 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 643.40 | 11-JAN-23:10 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.28 |
| February | 1249.26 | 26-FEB-16:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 5.23 | 0.00 |
| March | 1492.52 | 30-MAR-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 81.90 | 0.00 |
| April | 1446.65 | 15-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 49.50 | 0.00 |
| May | 1405.50 | 19-MAY-16:03 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 101.55 | 0.00 |
| June | 1591.97 | 06-JUN-17:08 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 244.08 | 0.00 |
| July | 1630.63 | 08-JUL-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 80.48 | 0.00 |
| August | 1763.83 | 29-AUG-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 214.23 | 0.00 |
| September | 1818.76 | 23-SEP-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 89.00 | 0.00 |
| October | 1819.36 | 10-OCT-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 51.37 | 0.00 |
| November | 1389.46 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 | 0.00 |
| December | 954.81 | 12-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.83 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 643.40 | 0.00 | 17.36 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1819.36 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 244.08 | 40.28 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 643.12 | 11-JAN-23:10 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.26 |
| February | 1260.31 | 26-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 12.45 | 0.00 |
| March | 1488.04 | 30-MAR-16:07 | 0.00 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 81.90 | 0.00 |
| April | 1444.32 | 15-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 49.50 | 0.00 |
| May | 1404.61 | 19-MAY-16:03 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 101.55 | 0.00 |
| June | 1589.17 | 06-JUN-17:08 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 244.08 | 0.00 |
| July | 1630.06 | 08-JUL-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 80.48 | 0.00 |
| August | 1762.66 | 29-AUG-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 214.23 | 0.00 |
| September | 1819.78 | 23-SEP-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 89.00 | 0.00 |
| October | 1821.93 | 10-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 59.38 | 0.00 |
| November | 1385.08 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 | 0.00 |
| December | 955.38 | 12-DEC-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.83 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 643.12 | 0.00 | 17.36 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1821.93 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 244.08 | 40.26 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 629.09 | 29-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.61 |
| February | 2165.91 | 26-FEB-16:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 3.15 | 0.00 |
| March | 2788.02 | 30-MAR-16:17 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 166.58 | 0.00 |
| April | 2699.55 | 17-APR-16:15 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 61.82 | 0.00 |
| May | 2975.10 | 19-MAY-17:30 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 172.22 | 0.00 |
| June | 3366.90 | 06-JUN-17:10 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 533.09 | 0.00 |
| July | 3443.52 | 08-JUL-16:17 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 170.61 | 0.00 |
| August | 3607.69 | 01-AUG-17:00 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 466.65 | 0.00 |
| September | 3262.33 | 23-SEP-16:05 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 180.27 | 0.00 |
| October | 3027.85 | 10-OCT-16:03 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 141.15 | 0.00 |
| November | 1988.10 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
| December | 1007.99 | 10-DEC-16:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106.61 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 629.09 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3607.69 | 950.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 533.09 | 226.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 271.73 | 31-JAN-23:30 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 412.96 |
| February | 834.26 | 26-FEB-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.62 |
| March | 2265.36 | 30-MAR-16:30 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 155.74 | 0.00 |
| April | 2252.76 | 17-APR-17:05 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 34.91 | 0.00 |
| May | 2827.81 | 19-MAY-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 172.22 | 0.00 |
| June | 3334.01 | 06-JUN-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 518.08 | 0.00 |
| July | 3237.32 | 08-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 165.28 | 0.00 |
| August | 3460.55 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 466.65 | 0.00 |
| September | 2745.59 | 07-SEP-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 181.45 | 0.00 |
| October | 1985.87 | 10-OCT-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 133.50 | 0.00 |
| November | 1066.85 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
| December | 280.38 | 14-DEC-00:50 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 374.32 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 271.73 | 123.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3460.55 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 518.08 | 412.96 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 655.29 | 29-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.61 |
| February | 1849.23 | 26-FEB-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 27.38 | 0.00 |
| March | 2369.68 | 30-MAR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 177.93 | 0.00 |
| April | 2396.69 | 16-APR-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 88.26 | 0.00 |
| May | 2499.45 | 30-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 152.49 | 0.00 |
| June | 2976.50 | 06-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 617.64 | 0.00 |
| July | 3056.34 | 08-JUL-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 175.93 | 0.00 |
| August | 3225.56 | 19-AUG-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 351.93 | 0.00 |
| September | 2970.08 | 06-SEP-13:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 227.87 | 0.00 |
| October | 2741.38 | 10-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 129.24 | 0.00 |
| November | 1620.44 | 05-NOV-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
| December | 946.44 | 12-DEC-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.14 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 655.29 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3225.56 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 617.64 | 226.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 271.74 | 31-JAN-23:30 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 412.97 |
| February | 606.22 | 28-FEB-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.17 |
| March | 1772.37 | 30-MAR-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 177.63 | 0.00 |
| April | 1726.07 | 16-APR-16:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 40.69 | 0.00 |
| May | 2326.59 | 30-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 152.49 | 0.00 |
| June | 2834.00 | 06-JUN-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 548.28 | 0.00 |
| July | 2830.10 | 08-JUL-16:03 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 175.93 | 0.00 |
| August | 2968.55 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 466.65 | 0.00 |
| September | 2326.79 | 07-SEP-16:10 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 185.91 | 0.00 |
| October | 1599.11 | 02-OCT-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 106.96 | 0.00 |
| November | 738.63 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
| December | 280.85 | 14-DEC-00:50 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 374.89 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 271.74 | 71.25 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2968.55 | 864.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 548.28 | 412.97 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 300.68 | 31-JAN-23:50 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 285.50 |
| February | 490.33 | 28-FEB-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.56 |
| March | 1475.96 | 30-MAR-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 100.48 | 0.00 |
| April | 1397.82 | 16-APR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 25.48 | 0.00 |
| May | 1806.07 | 30-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 91.98 | 0.00 |
| June | 2228.31 | 06-JUN-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 312.49 | 0.00 |
| July | 2260.11 | 08-JUL-16:13 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 102.91 | 0.00 |
| August | 2326.40 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 281.47 | 0.00 |
| September | 1861.06 | 07-SEP-16:08 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 112.14 | 0.00 |
| October | 1307.60 | 02-OCT-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 46.30 | 0.00 |
| November | 722.09 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
| December | 336.07 | 14-DEC-19:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.10 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 300.68 | 71.25 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2326.40 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 312.49 | 285.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 300.72 | 31-JAN-23:50 | 237.50 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 285.54 |
| February | 487.41 | 28-FEB-17:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.56 |
| March | 1466.97 | 30-MAR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 107.14 | 0.00 |
| April | 1396.72 | 16-APR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 25.48 | 0.00 |
| May | 1808.80 | 30-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 91.98 | 0.00 |
| June | 2218.49 | 06-JUN-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 321.55 | 0.00 |
| July | 2254.52 | 08-JUL-16:13 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 102.91 | 0.00 |
| August | 2318.03 | 01-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 281.47 | 0.00 |
| September | 1856.44 | 07-SEP-16:08 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 112.14 | 0.00 |
| October | 1303.50 | 02-OCT-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 46.30 | 0.00 |
| November | 713.73 | 05-NOV-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
| December | 336.08 | 14-DEC-19:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.11 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 300.72 | 71.25 | 21.70 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2318.03 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 321.55 | 285.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 715.95 | 29-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.69 |
| February | 1644.89 | 26-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 15.72 | 0.00 |
| March | 2049.05 | 30-MAR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 107.33 | 0.00 |
| April | 1950.68 | 16-APR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 48.56 | 0.00 |
| May | 2043.46 | 19-MAY-16:05 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 133.51 | 0.00 |
| June | 2314.14 | 24-JUN-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 204.57 | 0.00 |
| July | 2482.11 | 08-JUL-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 106.12 | 0.00 |
| August | 2515.19 | 19-AUG-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 212.27 | 0.00 |
| September | 2476.75 | 23-SEP-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 116.77 | 0.00 |
| October | 2402.48 | 10-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 77.96 | 0.00 |
| November | 1617.66 | 05-NOV-16:05 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
| December | 977.54 | 12-DEC-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.43 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 715.95 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2515.19 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 212.27 | 136.69 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 731.14 | 29-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.69 |
| February | 1655.03 | 26-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 15.72 | 0.00 |
| March | 2046.79 | 30-MAR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 107.33 | 0.00 |
| April | 1961.49 | 16-APR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 48.56 | 0.00 |
| May | 2037.51 | 19-MAY-16:05 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 133.51 | 0.00 |
| June | 2307.71 | 24-JUN-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 204.57 | 0.00 |
| July | 2477.36 | 08-JUL-16:03 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 106.12 | 0.00 |
| August | 2521.51 | 19-AUG-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 212.27 | 0.00 |
| September | 2476.32 | 23-SEP-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 116.77 | 0.00 |
| October | 2409.32 | 10-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 77.96 | 0.00 |
| November | 1608.40 | 05-NOV-16:05 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
| December | 979.69 | 12-DEC-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.43 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 731.14 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2521.51 | 1662.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 212.27 | 136.69 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.33 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.28 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.05 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.72 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.60 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.64 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.72 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.44 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.60 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.85 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.55 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.27 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.44 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.08 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.91 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.95 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.33 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.22 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.78 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.24 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.15 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.56 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.55 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.10 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.15 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.51 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.14 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.52 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.91 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.01 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.71 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.62 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.90 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.30 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.33 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.35 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.82 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.85 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.30 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.85 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.999851E+11 | 73121.38 | 07-JAN-18:30 | 0.899256E+11 | 95183.28 | 07-JAN-09:00 |
| February | 0.899113E+11 | 64646.73 | 08-FEB-18:30 | 0.564222E+11 | 124189.29 | 12-FEB-05:00 |
| March | 0.984730E+11 | 73986.27 | 30-MAR-16:19 | 0.114938E+11 | 37185.78 | 22-MAR-04:00 |
| April | 0.992604E+11 | 74667.49 | 17-APR-17:00 | 0.274420E+10 | 27770.36 | 06-APR-05:00 |
| May | 0.111462E+12 | 75436.69 | 19-MAY-17:10 | 0.136335E+09 | 5263.75 | 11-MAY-05:00 |
| June | 0.124334E+12 | 89527.22 | 29-JUN-17:10 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 0.134689E+12 | 89008.36 | 06-JUL-17:49 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 0.138974E+12 | 97401.70 | 29-AUG-17:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 0.115264E+12 | 92352.58 | 07-SEP-16:40 | 10017712.61 | 1338.03 | 29-SEP-04:00 |
| October | 0.101071E+12 | 75106.25 | 02-OCT-17:10 | 0.399065E+10 | 27140.60 | 26-OCT-05:00 |
| November | 0.926889E+11 | 64465.61 | 05-NOV-17:49 | 0.168317E+11 | 60871.16 | 22-NOV-05:00 |
| December | 0.977004E+11 | 61714.40 | 25-DEC-18:30 | 0.519446E+11 | 74130.76 | 17-DEC-04:00 |
| Annual Sum or Average | 0.130381E+13 | 0.233499E+12 | ||||
| Minimum of Months | 0.899113E+11 | 61714.40 | 0.00 | 0.00 | ||
| Maximum of Months | 0.138974E+12 | 97401.70 | 0.899256E+11 | 124189.29 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.495453E+10 | 0.389380E+11 | 0.00 | 0.772126E+10 | 0.00 | 0.00 | 4285123.34 | 0.00 | 0.00 | 0.00 | 0.399578E+11 | 0.00 |
| February | 0.760941E+10 | 0.422874E+10 | 0.351823E+11 | 0.00 | 0.622266E+10 | 0.00 | 0.00 | 0.554380E+09 | 0.00 | 0.00 | 0.00 | 0.361138E+11 | 0.00 |
| March | 0.845392E+10 | 0.432424E+10 | 0.389781E+11 | 0.00 | 0.550338E+10 | 0.00 | 0.00 | 0.232689E+10 | 0.00 | 0.00 | 0.00 | 0.388864E+11 | 0.00 |
| April | 0.814762E+10 | 0.382764E+10 | 0.376905E+11 | 0.00 | 0.645841E+10 | 0.00 | 0.00 | 0.741042E+10 | 0.00 | 0.00 | 0.00 | 0.357258E+11 | 0.00 |
| May | 0.843904E+10 | 0.364428E+10 | 0.389647E+11 | 0.00 | 0.903486E+10 | 0.00 | 0.00 | 0.167577E+11 | 0.00 | 0.00 | 0.00 | 0.346213E+11 | 0.00 |
| June | 0.817737E+10 | 0.339025E+10 | 0.377173E+11 | 0.00 | 0.125287E+11 | 0.00 | 0.00 | 0.309437E+11 | 0.00 | 0.00 | 0.00 | 0.315764E+11 | 0.00 |
| July | 0.840929E+10 | 0.355451E+10 | 0.389380E+11 | 0.00 | 0.144317E+11 | 0.00 | 0.00 | 0.379153E+11 | 0.00 | 0.00 | 0.00 | 0.314404E+11 | 0.00 |
| August | 0.845392E+10 | 0.381427E+10 | 0.389781E+11 | 0.00 | 0.152850E+11 | 0.00 | 0.00 | 0.411024E+11 | 0.00 | 0.00 | 0.00 | 0.313404E+11 | 0.00 |
| September | 0.814762E+10 | 0.403010E+10 | 0.376905E+11 | 0.00 | 0.106246E+11 | 0.00 | 0.00 | 0.234033E+11 | 0.00 | 0.00 | 0.00 | 0.313683E+11 | 0.00 |
| October | 0.842417E+10 | 0.453434E+10 | 0.389514E+11 | 0.00 | 0.676267E+10 | 0.00 | 0.00 | 0.800789E+10 | 0.00 | 0.00 | 0.00 | 0.343908E+11 | 0.00 |
| November | 0.814762E+10 | 0.471197E+10 | 0.376905E+11 | 0.00 | 0.527221E+10 | 0.00 | 0.00 | 0.134622E+10 | 0.00 | 0.00 | 0.00 | 0.355204E+11 | 0.00 |
| December | 0.840929E+10 | 0.504239E+10 | 0.389380E+11 | 0.00 | 0.638913E+10 | 0.00 | 0.00 | 0.156012E+09 | 0.00 | 0.00 | 0.00 | 0.387656E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.500572E+11 | 0.458657E+12 | 0.00 | 0.106235E+12 | 0.00 | 0.00 | 0.169929E+12 | 0.00 | 0.00 | 0.00 | 0.419707E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.339025E+10 | 0.351823E+11 | 0.00 | 0.527221E+10 | 0.00 | 0.00 | 4285123.34 | 0.00 | 0.00 | 0.00 | 0.313404E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.504239E+10 | 0.389781E+11 | 0.00 | 0.152850E+11 | 0.00 | 0.00 | 0.411024E+11 | 0.00 | 0.00 | 0.00 | 0.399578E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.899256E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.564222E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.114938E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.274420E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.136335E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 10017712.61 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.399065E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.168317E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.519446E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.233499E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.899256E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 5132.99 | 07-JAN-09:00 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 6173.41 | 12-FEB-05:00 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 5622.74 | 30-MAR-16:10 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 5569.50 | 17-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 6649.99 | 30-MAY-15:09 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 8237.36 | 06-JUN-16:00 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 8691.95 | 08-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 8828.93 | 01-AUG-16:00 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 7976.60 | 07-SEP-16:10 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 6811.36 | 10-OCT-16:10 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 4843.74 | 05-NOV-16:10 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 4396.77 | 17-DEC-04:00 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 4396.77 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 8828.93 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 515.24 | 29-JAN-14:00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 37629.12 | 20-JAN-07:19 | 0.00 |
| February | 6553.70 | 28-FEB-15:09 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 32908.25 | 11-FEB-07:10 | 0.00 |
| March | 14333.56 | 30-MAR-15:00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 34010.93 | 13-MAR-05:40 | 0.00 |
| April | 14307.82 | 17-APR-15:30 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 30813.84 | 24-APR-07:00 | 0.00 |
| May | 19635.06 | 30-MAY-15:09 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 29444.03 | 10-MAY-06:10 | 0.00 |
| June | 26261.86 | 06-JUN-15:09 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 29512.97 | 29-JUN-17:10 | 0.00 |
| July | 28297.56 | 08-JUL-16:10 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 33990.18 | 29-JUL-06:40 | 0.00 |
| August | 28859.76 | 01-AUG-16:00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 36951.12 | 27-AUG-06:00 | 0.00 |
| September | 25039.76 | 07-SEP-15:30 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 37012.54 | 14-SEP-06:49 | 0.00 |
| October | 19945.59 | 10-OCT-15:00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 32591.92 | 05-OCT-06:30 | 0.00 |
| November | 11190.69 | 05-NOV-16:10 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 32702.65 | 17-NOV-07:30 | 0.00 |
| December | 4290.56 | 12-DEC-13:00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 31358.59 | 15-DEC-08:30 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 515.24 | 0.00 | 0.00 | 0.00 | 29444.03 | 0.00 | |||
| Maximum of Months | 28859.76 | 0.00 | 0.00 | 0.00 | 37629.12 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 73121.38 | 07-JAN-18:30 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 4838.42 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64646.73 | 08-FEB-18:30 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2387.44 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 73986.27 | 30-MAR-16:19 | 4289.87 | 22709.69 | 0.00 | 0.00 | 5600.96 | 0.00 | 0.00 | 14219.16 | 0.00 |
| April | 74667.49 | 17-APR-17:00 | 5231.74 | 22609.62 | 0.00 | 0.00 | 5082.05 | 0.00 | 0.00 | 12185.23 | 0.00 |
| May | 75436.69 | 19-MAY-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 6509.06 | 0.00 | 0.00 | 18084.50 | 0.00 |
| June | 89527.22 | 29-JUN-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7934.34 | 0.00 | 0.00 | 24238.55 | 0.00 |
| July | 89008.36 | 06-JUL-17:49 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8163.08 | 0.00 | 0.00 | 25258.48 | 0.00 |
| August | 97401.70 | 29-AUG-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8194.28 | 0.00 | 0.00 | 25094.75 | 0.00 |
| September | 92352.58 | 07-SEP-16:40 | 4289.87 | 22709.69 | 0.00 | 0.00 | 7830.78 | 0.00 | 0.00 | 24063.39 | 0.00 |
| October | 75106.25 | 02-OCT-17:10 | 5231.74 | 22609.62 | 0.00 | 0.00 | 5762.89 | 0.00 | 0.00 | 14702.38 | 0.00 |
| November | 64465.61 | 05-NOV-17:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 3478.76 | 0.00 | 0.00 | 6402.38 | 0.00 |
| December | 61714.40 | 25-DEC-18:30 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2868.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 61714.40 | 4289.87 | 22609.62 | 0.00 | 0.00 | 2387.44 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 97401.70 | 5231.74 | 22709.69 | 3183.33 | 0.00 | 8194.28 | 0.00 | 0.00 | 25258.48 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 95183.28 | 07-JAN-09:00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 124189.29 | 12-FEB-05:00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 37185.78 | 22-MAR-04:00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 27770.36 | 06-APR-05:00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 5263.75 | 11-MAY-05:00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 1338.03 | 29-SEP-04:00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 27140.60 | 26-OCT-05:00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 60871.16 | 22-NOV-05:00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 74130.76 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 124189.29 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.15 | 384.33 | 21.13 | 384.33 | 21.12 |
| February | 473.00 | 21.40 | 212.67 | 21.31 | 212.67 | 21.26 |
| March | 495.83 | 21.97 | 46.33 | 21.89 | 46.33 | 21.83 |
| April | 429.50 | 22.67 | 70.83 | 22.78 | 54.33 | 22.83 |
| May | 257.50 | 23.47 | 277.83 | 23.65 | 140.67 | 23.65 |
| June | 180.33 | 23.96 | 390.50 | 23.99 | 148.50 | 23.99 |
| July | 232.50 | 24.00 | 533.00 | 24.00 | 232.50 | 24.00 |
| August | 265.50 | 24.00 | 506.00 | 24.00 | 265.50 | 24.00 |
| September | 108.33 | 23.98 | 450.83 | 23.99 | 103.67 | 23.99 |
| October | 256.17 | 23.09 | 181.00 | 23.44 | 60.17 | 23.49 |
| November | 429.17 | 22.53 | 64.83 | 22.69 | 18.00 | 22.70 |
| December | 531.67 | 21.36 | 116.00 | 21.32 | 116.00 | 21.29 |
| Annual Sum or Average | 4192.50 | 22.39 | 3234.17 | 22.78 | 1782.67 | 22.77 |
| Minimum of Months | 108.33 | 21.15 | 46.33 | 21.13 | 18.00 | 21.12 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 384.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.11 | 618.33 | 21.10 | 618.33 | 21.10 |
| February | 672.00 | 21.24 | 378.67 | 21.19 | 378.67 | 21.16 |
| March | 740.67 | 21.61 | 166.17 | 21.52 | 166.17 | 21.45 |
| April | 659.00 | 22.55 | 100.00 | 22.59 | 89.50 | 22.60 |
| May | 386.33 | 23.45 | 357.17 | 23.63 | 184.83 | 23.64 |
| June | 239.33 | 23.97 | 578.50 | 23.99 | 200.83 | 23.99 |
| July | 294.00 | 24.00 | 744.00 | 24.00 | 294.00 | 24.00 |
| August | 366.33 | 24.00 | 744.00 | 24.00 | 366.33 | 24.00 |
| September | 172.00 | 23.98 | 594.33 | 23.99 | 164.33 | 23.99 |
| October | 533.50 | 22.95 | 210.33 | 23.22 | 93.67 | 23.28 |
| November | 689.17 | 21.99 | 95.00 | 21.99 | 82.17 | 21.95 |
| December | 744.00 | 21.20 | 425.17 | 21.17 | 425.17 | 21.15 |
| Annual Sum or Average | 6240.33 | 22.24 | 5011.67 | 22.58 | 3064.00 | 22.54 |
| Minimum of Months | 172.00 | 21.11 | 95.00 | 21.10 | 82.17 | 21.10 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 618.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 140.00 | 21.14 | 108.50 | 21.04 | 108.50 | 21.01 |
| February | 130.83 | 21.73 | 72.50 | 21.44 | 72.50 | 21.30 |
| March | 130.00 | 22.90 | 18.83 | 22.89 | 6.67 | 22.79 |
| April | 63.33 | 23.38 | 39.00 | 23.61 | 3.83 | 23.57 |
| May | 18.50 | 24.44 | 119.33 | 24.23 | 9.83 | 24.28 |
| June | 21.50 | 25.19 | 151.17 | 24.36 | 21.50 | 24.45 |
| July | 25.67 | 25.19 | 140.00 | 24.39 | 25.67 | 24.50 |
| August | 32.50 | 25.21 | 161.00 | 24.41 | 32.50 | 24.53 |
| September | 10.33 | 25.44 | 140.00 | 24.32 | 10.33 | 24.39 |
| October | 31.33 | 23.55 | 93.67 | 24.02 | 6.33 | 24.07 |
| November | 81.17 | 23.12 | 17.50 | 23.21 | 1.83 | 23.16 |
| December | 128.17 | 21.94 | 43.33 | 21.77 | 36.67 | 21.58 |
| Annual Sum or Average | 813.33 | 22.63 | 1104.83 | 23.15 | 336.17 | 23.02 |
| Minimum of Months | 10.33 | 21.14 | 17.50 | 21.04 | 1.83 | 21.01 |
| Maximum of Months | 140.00 | 25.44 | 161.00 | 24.41 | 108.50 | 24.53 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.11 | 618.17 | 21.10 | 618.17 | 21.10 |
| February | 672.00 | 21.24 | 376.17 | 21.19 | 376.17 | 21.16 |
| March | 744.00 | 21.59 | 175.50 | 21.50 | 175.50 | 21.43 |
| April | 658.83 | 22.54 | 96.50 | 22.59 | 87.50 | 22.60 |
| May | 379.33 | 23.46 | 366.33 | 23.64 | 181.33 | 23.64 |
| June | 222.17 | 23.97 | 582.00 | 23.99 | 190.50 | 23.99 |
| July | 278.83 | 24.00 | 744.00 | 24.00 | 278.83 | 24.00 |
| August | 363.67 | 24.00 | 744.00 | 24.00 | 363.67 | 24.00 |
| September | 163.50 | 23.98 | 593.00 | 23.99 | 156.17 | 23.99 |
| October | 532.17 | 22.97 | 209.67 | 23.24 | 93.00 | 23.30 |
| November | 689.17 | 21.97 | 86.33 | 21.98 | 75.67 | 21.95 |
| December | 744.00 | 21.20 | 427.00 | 21.17 | 427.00 | 21.15 |
| Annual Sum or Average | 6191.67 | 22.22 | 5018.67 | 22.57 | 3023.50 | 22.53 |
| Minimum of Months | 163.50 | 21.11 | 86.33 | 21.10 | 75.67 | 21.10 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 618.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.12 | 559.33 | 21.11 | 559.33 | 21.11 |
| February | 672.00 | 21.28 | 319.33 | 21.22 | 319.33 | 21.19 |
| March | 744.00 | 21.75 | 77.67 | 21.69 | 77.67 | 21.64 |
| April | 613.67 | 22.76 | 83.00 | 22.88 | 52.50 | 22.93 |
| May | 340.33 | 23.66 | 369.33 | 23.79 | 170.83 | 23.79 |
| June | 214.67 | 23.99 | 564.67 | 24.00 | 182.83 | 24.00 |
| July | 296.33 | 24.00 | 744.00 | 24.00 | 296.33 | 24.00 |
| August | 380.00 | 24.00 | 744.00 | 24.00 | 380.00 | 24.00 |
| September | 157.67 | 24.00 | 583.50 | 24.00 | 157.67 | 24.00 |
| October | 503.17 | 23.25 | 210.67 | 23.45 | 91.50 | 23.50 |
| November | 669.33 | 22.20 | 71.50 | 22.22 | 53.67 | 22.21 |
| December | 744.00 | 21.24 | 290.50 | 21.21 | 290.50 | 21.19 |
| Annual Sum or Average | 6079.17 | 22.33 | 4617.50 | 22.70 | 2632.17 | 22.67 |
| Minimum of Months | 157.67 | 21.12 | 71.50 | 21.11 | 52.50 | 21.11 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 559.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.12 | 559.00 | 21.11 | 559.00 | 21.11 |
| February | 672.00 | 21.28 | 318.83 | 21.22 | 318.83 | 21.19 |
| March | 744.00 | 21.75 | 78.00 | 21.69 | 78.00 | 21.64 |
| April | 613.17 | 22.76 | 83.33 | 22.88 | 52.83 | 22.93 |
| May | 340.00 | 23.66 | 372.50 | 23.79 | 170.83 | 23.79 |
| June | 213.67 | 23.99 | 564.83 | 24.00 | 182.17 | 24.00 |
| July | 295.50 | 24.00 | 744.00 | 24.00 | 295.50 | 24.00 |
| August | 379.00 | 24.00 | 744.00 | 24.00 | 379.00 | 24.00 |
| September | 157.17 | 24.00 | 583.50 | 24.00 | 157.17 | 24.00 |
| October | 502.83 | 23.25 | 211.67 | 23.45 | 91.33 | 23.50 |
| November | 669.50 | 22.20 | 71.33 | 22.22 | 53.50 | 22.21 |
| December | 744.00 | 21.24 | 289.50 | 21.21 | 289.50 | 21.19 |
| Annual Sum or Average | 6074.83 | 22.33 | 4620.50 | 22.70 | 2627.67 | 22.67 |
| Minimum of Months | 157.17 | 21.12 | 71.33 | 21.11 | 52.83 | 21.11 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 559.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.19 | 278.33 | 21.16 | 278.33 | 21.14 |
| February | 473.00 | 21.55 | 162.83 | 21.43 | 162.83 | 21.37 |
| March | 492.33 | 22.35 | 0.00 | 22.35 | 0.00 | 22.35 |
| April | 370.67 | 22.97 | 68.00 | 23.11 | 36.50 | 23.16 |
| May | 217.17 | 23.71 | 299.17 | 23.83 | 123.67 | 23.83 |
| June | 161.33 | 23.99 | 386.50 | 24.00 | 134.00 | 24.00 |
| July | 232.33 | 24.00 | 533.00 | 24.00 | 232.33 | 24.00 |
| August | 269.83 | 24.00 | 506.00 | 24.00 | 269.83 | 24.00 |
| September | 98.33 | 24.00 | 468.50 | 24.00 | 98.33 | 24.00 |
| October | 199.33 | 23.44 | 185.17 | 23.70 | 56.17 | 23.73 |
| November | 394.17 | 22.91 | 73.67 | 23.08 | 11.00 | 23.10 |
| December | 521.17 | 21.52 | 30.83 | 21.50 | 30.83 | 21.49 |
| Annual Sum or Average | 3962.67 | 22.55 | 2992.00 | 22.97 | 1433.83 | 22.98 |
| Minimum of Months | 98.33 | 21.19 | 0.00 | 21.16 | 0.00 | 21.14 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 278.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.18 | 327.67 | 21.15 | 327.67 | 21.13 |
| February | 473.00 | 21.55 | 178.17 | 21.43 | 178.17 | 21.36 |
| March | 482.00 | 22.36 | 0.33 | 22.36 | 0.33 | 22.36 |
| April | 349.50 | 22.99 | 75.17 | 23.15 | 35.33 | 23.19 |
| May | 184.33 | 23.71 | 313.17 | 23.85 | 102.83 | 23.85 |
| June | 129.17 | 24.00 | 392.67 | 24.00 | 116.83 | 24.00 |
| July | 186.67 | 24.00 | 533.00 | 24.00 | 186.67 | 24.00 |
| August | 217.50 | 24.00 | 506.00 | 24.00 | 217.50 | 24.00 |
| September | 77.50 | 24.00 | 474.67 | 24.00 | 77.50 | 24.00 |
| October | 187.33 | 23.47 | 188.50 | 23.73 | 54.00 | 23.76 |
| November | 384.33 | 22.91 | 76.33 | 23.09 | 10.33 | 23.11 |
| December | 520.33 | 21.51 | 38.33 | 21.49 | 38.00 | 21.47 |
| Annual Sum or Average | 3724.67 | 22.48 | 3104.00 | 22.93 | 1345.17 | 22.91 |
| Minimum of Months | 77.50 | 21.18 | 0.33 | 21.15 | 0.33 | 21.13 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 327.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.24 | 239.83 | 21.19 | 239.83 | 21.17 |
| February | 466.50 | 21.71 | 142.50 | 21.57 | 142.50 | 21.48 |
| March | 389.00 | 22.57 | 30.17 | 22.67 | 0.00 | 22.67 |
| April | 198.33 | 23.14 | 160.00 | 23.52 | 18.67 | 23.54 |
| May | 103.83 | 23.78 | 379.33 | 23.94 | 59.17 | 23.95 |
| June | 130.67 | 23.99 | 400.50 | 24.00 | 116.33 | 24.00 |
| July | 214.50 | 24.00 | 533.00 | 24.00 | 214.50 | 24.00 |
| August | 272.83 | 24.00 | 506.00 | 24.00 | 272.83 | 24.00 |
| September | 136.33 | 23.94 | 425.33 | 23.98 | 124.00 | 23.99 |
| October | 298.67 | 22.93 | 170.33 | 23.29 | 64.50 | 23.34 |
| November | 430.67 | 22.39 | 74.83 | 22.54 | 27.67 | 22.53 |
| December | 518.50 | 21.40 | 84.17 | 21.37 | 84.17 | 21.34 |
| Annual Sum or Average | 3692.83 | 22.47 | 3146.00 | 22.97 | 1364.17 | 22.97 |
| Minimum of Months | 103.83 | 21.24 | 30.17 | 21.19 | 0.00 | 21.17 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 272.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.14 | 515.33 | 21.12 | 515.33 | 21.12 |
| February | 672.00 | 21.47 | 261.67 | 21.37 | 261.67 | 21.31 |
| March | 633.83 | 22.17 | 63.17 | 22.23 | 27.00 | 22.18 |
| April | 342.50 | 23.01 | 170.83 | 23.33 | 28.83 | 23.37 |
| May | 146.67 | 23.75 | 542.83 | 23.94 | 81.83 | 23.94 |
| June | 175.00 | 23.99 | 596.83 | 24.00 | 158.67 | 24.00 |
| July | 271.83 | 24.00 | 744.00 | 24.00 | 271.83 | 24.00 |
| August | 376.00 | 24.00 | 744.00 | 24.00 | 376.00 | 24.00 |
| September | 210.67 | 23.91 | 563.83 | 23.98 | 183.67 | 23.98 |
| October | 568.00 | 22.77 | 205.33 | 23.06 | 96.67 | 23.14 |
| November | 675.83 | 21.85 | 105.50 | 21.86 | 89.00 | 21.84 |
| December | 744.00 | 21.26 | 319.17 | 21.22 | 319.17 | 21.20 |
| Annual Sum or Average | 5560.33 | 22.28 | 4832.50 | 22.74 | 2409.67 | 22.71 |
| Minimum of Months | 146.67 | 21.14 | 63.17 | 21.12 | 27.00 | 21.12 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 515.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.23 | 247.50 | 21.19 | 247.50 | 21.17 |
| February | 466.33 | 21.72 | 144.00 | 21.57 | 144.00 | 21.48 |
| March | 390.00 | 22.55 | 25.50 | 22.64 | 0.00 | 22.64 |
| April | 205.33 | 23.14 | 147.50 | 23.50 | 19.83 | 23.52 |
| May | 102.50 | 23.77 | 373.67 | 23.94 | 58.50 | 23.94 |
| June | 137.33 | 23.98 | 401.00 | 24.00 | 123.17 | 24.00 |
| July | 206.33 | 24.00 | 533.00 | 24.00 | 206.33 | 24.00 |
| August | 285.83 | 24.00 | 506.00 | 24.00 | 285.83 | 24.00 |
| September | 135.00 | 23.93 | 423.00 | 23.98 | 120.50 | 23.98 |
| October | 300.17 | 22.91 | 168.67 | 23.27 | 65.50 | 23.33 |
| November | 433.33 | 22.40 | 74.00 | 22.55 | 29.33 | 22.54 |
| December | 519.17 | 21.40 | 86.00 | 21.36 | 86.00 | 21.34 |
| Annual Sum or Average | 3714.33 | 22.47 | 3129.83 | 22.96 | 1386.50 | 22.96 |
| Minimum of Months | 102.50 | 21.23 | 25.50 | 21.19 | 0.00 | 21.17 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 285.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.14 | 515.17 | 21.12 | 515.17 | 21.12 |
| February | 672.00 | 21.49 | 267.00 | 21.38 | 267.00 | 21.32 |
| March | 634.67 | 22.17 | 47.17 | 22.19 | 23.83 | 22.16 |
| April | 337.17 | 23.04 | 169.33 | 23.36 | 28.83 | 23.39 |
| May | 138.17 | 23.77 | 537.67 | 23.94 | 76.00 | 23.95 |
| June | 163.83 | 23.99 | 602.17 | 24.00 | 149.67 | 24.00 |
| July | 253.00 | 24.00 | 744.00 | 24.00 | 253.00 | 24.00 |
| August | 371.00 | 24.00 | 744.00 | 24.00 | 371.00 | 24.00 |
| September | 204.50 | 23.90 | 559.33 | 23.97 | 175.67 | 23.98 |
| October | 562.17 | 22.80 | 206.50 | 23.09 | 96.00 | 23.16 |
| November | 676.00 | 21.83 | 100.17 | 21.85 | 84.50 | 21.83 |
| December | 744.00 | 21.25 | 321.33 | 21.21 | 321.33 | 21.19 |
| Annual Sum or Average | 5500.50 | 22.26 | 4813.83 | 22.74 | 2362.00 | 22.70 |
| Minimum of Months | 138.17 | 21.14 | 47.17 | 21.12 | 23.83 | 21.12 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 515.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.17 | 448.17 | 21.14 | 448.17 | 21.13 |
| February | 672.00 | 21.64 | 209.33 | 21.51 | 209.33 | 21.43 |
| March | 621.50 | 22.46 | 26.33 | 22.51 | 3.50 | 22.50 |
| April | 286.83 | 23.18 | 175.50 | 23.49 | 14.83 | 23.50 |
| May | 99.33 | 23.87 | 500.00 | 23.97 | 54.50 | 23.98 |
| June | 154.83 | 24.00 | 581.33 | 24.00 | 149.17 | 24.00 |
| July | 267.67 | 24.00 | 744.00 | 24.00 | 267.67 | 24.00 |
| August | 390.50 | 24.00 | 742.50 | 24.00 | 390.50 | 24.00 |
| September | 173.00 | 24.00 | 554.00 | 24.00 | 171.83 | 24.00 |
| October | 525.33 | 23.11 | 208.00 | 23.34 | 93.33 | 23.39 |
| November | 660.33 | 22.11 | 95.00 | 22.19 | 57.00 | 22.17 |
| December | 742.33 | 21.33 | 202.50 | 21.29 | 202.50 | 21.27 |
| Annual Sum or Average | 5337.67 | 22.39 | 4486.67 | 22.86 | 2062.33 | 22.83 |
| Minimum of Months | 99.33 | 21.17 | 26.33 | 21.14 | 3.50 | 21.13 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 448.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.17 | 448.33 | 21.14 | 448.33 | 21.13 |
| February | 672.00 | 21.64 | 209.17 | 21.51 | 209.17 | 21.43 |
| March | 622.50 | 22.47 | 26.00 | 22.51 | 3.33 | 22.50 |
| April | 287.50 | 23.18 | 175.50 | 23.49 | 15.00 | 23.51 |
| May | 100.00 | 23.87 | 500.83 | 23.97 | 55.17 | 23.98 |
| June | 155.00 | 24.00 | 581.33 | 24.00 | 149.33 | 24.00 |
| July | 265.83 | 24.00 | 744.00 | 24.00 | 265.83 | 24.00 |
| August | 390.17 | 24.00 | 743.00 | 24.00 | 390.17 | 24.00 |
| September | 172.83 | 24.00 | 554.67 | 24.00 | 171.67 | 24.00 |
| October | 524.50 | 23.11 | 208.83 | 23.34 | 93.33 | 23.39 |
| November | 660.50 | 22.11 | 94.50 | 22.19 | 56.83 | 22.17 |
| December | 742.33 | 21.33 | 202.17 | 21.29 | 202.17 | 21.27 |
| Annual Sum or Average | 5337.17 | 22.39 | 4488.33 | 22.86 | 2060.33 | 22.83 |
| Minimum of Months | 100.00 | 21.17 | 26.00 | 21.14 | 3.33 | 21.13 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 448.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.37 | 153.17 | 21.31 | 153.17 | 21.27 |
| February | 458.50 | 21.99 | 99.83 | 21.83 | 99.83 | 21.72 |
| March | 362.33 | 23.00 | 34.33 | 23.08 | 0.00 | 23.08 |
| April | 158.50 | 23.42 | 154.67 | 23.70 | 7.33 | 23.71 |
| May | 61.33 | 23.87 | 359.67 | 23.98 | 34.00 | 23.98 |
| June | 121.17 | 24.00 | 395.00 | 24.00 | 114.67 | 24.00 |
| July | 209.67 | 24.00 | 533.00 | 24.00 | 209.67 | 24.00 |
| August | 277.67 | 24.00 | 506.00 | 24.00 | 277.67 | 24.00 |
| September | 111.33 | 24.00 | 440.50 | 24.00 | 110.50 | 24.00 |
| October | 232.67 | 23.30 | 175.33 | 23.58 | 59.33 | 23.62 |
| November | 398.00 | 22.88 | 74.50 | 23.05 | 9.83 | 23.07 |
| December | 505.33 | 21.64 | 25.83 | 21.65 | 21.00 | 21.63 |
| Annual Sum or Average | 3429.50 | 22.66 | 2951.83 | 23.16 | 1097.00 | 23.17 |
| Minimum of Months | 61.33 | 21.37 | 25.83 | 21.31 | 0.00 | 21.27 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 277.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.37 | 153.67 | 21.31 | 153.67 | 21.27 |
| February | 458.33 | 21.99 | 100.17 | 21.83 | 100.17 | 21.72 |
| March | 362.33 | 23.00 | 34.33 | 23.08 | 0.00 | 23.08 |
| April | 157.50 | 23.42 | 154.33 | 23.70 | 7.33 | 23.71 |
| May | 60.83 | 23.87 | 359.17 | 23.98 | 34.00 | 23.98 |
| June | 121.33 | 24.00 | 394.67 | 24.00 | 114.67 | 24.00 |
| July | 209.83 | 24.00 | 533.00 | 24.00 | 209.83 | 24.00 |
| August | 278.17 | 24.00 | 506.00 | 24.00 | 278.17 | 24.00 |
| September | 111.33 | 24.00 | 440.50 | 24.00 | 110.50 | 24.00 |
| October | 233.00 | 23.30 | 175.33 | 23.58 | 59.50 | 23.62 |
| November | 398.83 | 22.88 | 74.50 | 23.05 | 9.83 | 23.07 |
| December | 505.33 | 21.64 | 26.00 | 21.65 | 21.17 | 21.63 |
| Annual Sum or Average | 3429.83 | 22.66 | 2951.67 | 23.15 | 1098.83 | 23.17 |
| Minimum of Months | 60.83 | 21.37 | 26.00 | 21.31 | 0.00 | 21.27 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 278.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.21 | 406.50 | 21.16 | 406.50 | 21.14 |
| February | 459.00 | 21.41 | 235.33 | 21.30 | 235.33 | 21.25 |
| March | 418.33 | 21.87 | 130.67 | 21.84 | 102.17 | 21.72 |
| April | 318.00 | 22.33 | 172.00 | 22.73 | 55.17 | 22.70 |
| May | 219.00 | 23.11 | 330.00 | 23.57 | 103.50 | 23.58 |
| June | 200.67 | 23.77 | 397.00 | 23.92 | 151.17 | 23.94 |
| July | 254.67 | 23.97 | 531.83 | 23.98 | 254.67 | 23.98 |
| August | 294.67 | 24.00 | 506.00 | 24.00 | 294.67 | 24.00 |
| September | 260.67 | 23.53 | 387.33 | 23.81 | 173.33 | 23.84 |
| October | 396.17 | 22.10 | 161.33 | 22.52 | 80.00 | 22.59 |
| November | 460.67 | 21.74 | 177.67 | 21.73 | 156.33 | 21.66 |
| December | 527.50 | 21.27 | 325.83 | 21.21 | 325.83 | 21.18 |
| Annual Sum or Average | 4342.33 | 22.23 | 3761.50 | 22.59 | 2338.67 | 22.55 |
| Minimum of Months | 200.67 | 21.21 | 130.67 | 21.16 | 55.17 | 21.14 |
| Maximum of Months | 533.00 | 24.00 | 531.83 | 24.00 | 406.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.13 | 624.00 | 21.11 | 624.00 | 21.11 |
| February | 670.00 | 21.36 | 383.83 | 21.26 | 383.83 | 21.22 |
| March | 653.00 | 21.74 | 227.00 | 21.70 | 188.17 | 21.59 |
| April | 455.17 | 22.26 | 237.00 | 22.64 | 82.33 | 22.59 |
| May | 298.17 | 23.11 | 482.17 | 23.60 | 135.17 | 23.60 |
| June | 253.50 | 23.79 | 600.50 | 23.94 | 194.83 | 23.95 |
| July | 317.33 | 23.97 | 743.00 | 23.98 | 317.33 | 23.98 |
| August | 389.00 | 24.00 | 744.00 | 24.00 | 389.00 | 24.00 |
| September | 362.67 | 23.50 | 538.17 | 23.79 | 236.17 | 23.83 |
| October | 622.67 | 22.04 | 211.67 | 22.38 | 130.17 | 22.47 |
| November | 686.33 | 21.55 | 319.67 | 21.48 | 310.67 | 21.43 |
| December | 744.00 | 21.21 | 549.17 | 21.17 | 549.17 | 21.15 |
| Annual Sum or Average | 6195.83 | 22.12 | 5660.17 | 22.49 | 3540.83 | 22.43 |
| Minimum of Months | 253.50 | 21.13 | 211.67 | 21.11 | 82.33 | 21.11 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 624.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.20 | 408.17 | 21.16 | 408.17 | 21.14 |
| February | 458.33 | 21.40 | 237.83 | 21.30 | 237.83 | 21.25 |
| March | 432.17 | 21.90 | 124.67 | 21.83 | 103.33 | 21.72 |
| April | 323.83 | 22.31 | 165.33 | 22.69 | 58.00 | 22.65 |
| May | 220.50 | 23.11 | 330.67 | 23.57 | 105.17 | 23.57 |
| June | 203.00 | 23.78 | 396.33 | 23.92 | 154.33 | 23.94 |
| July | 250.50 | 23.97 | 532.00 | 23.98 | 250.50 | 23.98 |
| August | 300.67 | 24.00 | 506.00 | 24.00 | 300.67 | 24.00 |
| September | 263.83 | 23.53 | 385.00 | 23.80 | 175.33 | 23.84 |
| October | 400.67 | 22.11 | 158.67 | 22.51 | 82.67 | 22.59 |
| November | 462.17 | 21.74 | 173.33 | 21.71 | 156.83 | 21.65 |
| December | 529.00 | 21.27 | 327.67 | 21.21 | 327.67 | 21.18 |
| Annual Sum or Average | 4377.67 | 22.23 | 3745.67 | 22.58 | 2360.50 | 22.54 |
| Minimum of Months | 203.00 | 21.20 | 124.67 | 21.16 | 58.00 | 21.14 |
| Maximum of Months | 533.00 | 24.00 | 532.00 | 24.00 | 408.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.12 | 625.33 | 21.11 | 625.33 | 21.11 |
| February | 672.00 | 21.37 | 376.50 | 21.27 | 376.50 | 21.23 |
| March | 666.17 | 21.74 | 220.83 | 21.71 | 181.67 | 21.61 |
| April | 455.17 | 22.30 | 228.17 | 22.67 | 77.17 | 22.63 |
| May | 283.67 | 23.12 | 490.17 | 23.61 | 132.17 | 23.62 |
| June | 238.33 | 23.80 | 603.83 | 23.94 | 186.00 | 23.95 |
| July | 299.00 | 23.97 | 743.17 | 23.98 | 299.00 | 23.98 |
| August | 383.33 | 24.00 | 744.00 | 24.00 | 383.33 | 24.00 |
| September | 348.00 | 23.49 | 543.17 | 23.80 | 228.00 | 23.84 |
| October | 628.00 | 22.09 | 213.17 | 22.42 | 129.17 | 22.50 |
| November | 690.33 | 21.52 | 320.50 | 21.47 | 309.50 | 21.42 |
| December | 744.00 | 21.20 | 558.67 | 21.16 | 558.67 | 21.15 |
| Annual Sum or Average | 6152.00 | 22.10 | 5667.50 | 22.49 | 3486.50 | 22.43 |
| Minimum of Months | 238.33 | 21.12 | 213.17 | 21.11 | 77.17 | 21.11 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 625.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.14 | 618.50 | 21.12 | 618.50 | 21.11 |
| February | 672.00 | 21.39 | 350.83 | 21.29 | 350.83 | 21.24 |
| March | 662.17 | 21.82 | 173.17 | 21.80 | 136.17 | 21.70 |
| April | 449.33 | 22.48 | 200.17 | 22.77 | 70.67 | 22.73 |
| May | 256.83 | 23.31 | 481.50 | 23.72 | 123.00 | 23.73 |
| June | 233.50 | 23.86 | 589.67 | 23.96 | 181.50 | 23.97 |
| July | 306.67 | 23.99 | 744.00 | 23.99 | 306.67 | 23.99 |
| August | 382.83 | 24.00 | 744.00 | 24.00 | 382.83 | 24.00 |
| September | 333.50 | 23.64 | 532.00 | 23.86 | 227.33 | 23.89 |
| October | 630.00 | 22.20 | 199.83 | 22.52 | 121.00 | 22.61 |
| November | 681.33 | 21.58 | 255.33 | 21.55 | 243.00 | 21.50 |
| December | 742.83 | 21.22 | 508.33 | 21.18 | 508.33 | 21.16 |
| Annual Sum or Average | 6095.00 | 22.16 | 5397.33 | 22.54 | 3269.83 | 22.49 |
| Minimum of Months | 233.50 | 21.14 | 173.17 | 21.12 | 70.67 | 21.11 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 618.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.14 | 618.67 | 21.12 | 618.67 | 21.11 |
| February | 672.00 | 21.39 | 350.83 | 21.29 | 350.83 | 21.24 |
| March | 662.17 | 21.82 | 173.17 | 21.80 | 136.17 | 21.70 |
| April | 449.33 | 22.48 | 200.50 | 22.77 | 70.67 | 22.73 |
| May | 256.33 | 23.31 | 481.33 | 23.72 | 123.50 | 23.73 |
| June | 232.50 | 23.86 | 590.67 | 23.96 | 181.33 | 23.97 |
| July | 306.17 | 23.99 | 744.00 | 23.99 | 306.17 | 23.99 |
| August | 383.00 | 24.00 | 744.00 | 24.00 | 383.00 | 24.00 |
| September | 332.50 | 23.64 | 532.33 | 23.86 | 227.00 | 23.89 |
| October | 629.67 | 22.20 | 200.00 | 22.52 | 121.33 | 22.61 |
| November | 681.33 | 21.58 | 256.00 | 21.55 | 242.67 | 21.50 |
| December | 742.67 | 21.22 | 508.67 | 21.18 | 508.67 | 21.16 |
| Annual Sum or Average | 6091.67 | 22.16 | 5400.17 | 22.54 | 3270.00 | 22.49 |
| Minimum of Months | 232.50 | 21.14 | 173.17 | 21.12 | 70.67 | 21.11 |
| Maximum of Months | 744.00 | 24.00 | 744.00 | 24.00 | 618.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.26 | 375.33 | 21.19 | 375.33 | 21.16 |
| February | 461.33 | 21.53 | 206.33 | 21.40 | 206.33 | 21.33 |
| March | 417.33 | 22.09 | 76.33 | 22.06 | 54.83 | 21.97 |
| April | 300.17 | 22.58 | 153.00 | 22.93 | 44.83 | 22.90 |
| May | 183.00 | 23.32 | 328.67 | 23.71 | 91.67 | 23.72 |
| June | 187.17 | 23.85 | 389.67 | 23.95 | 143.17 | 23.96 |
| July | 248.00 | 23.99 | 533.00 | 23.99 | 248.00 | 23.99 |
| August | 286.83 | 24.00 | 506.00 | 24.00 | 286.83 | 24.00 |
| September | 233.83 | 23.68 | 390.00 | 23.88 | 164.00 | 23.90 |
| October | 382.00 | 22.35 | 156.83 | 22.73 | 74.17 | 22.79 |
| November | 449.33 | 21.94 | 134.67 | 21.96 | 107.50 | 21.90 |
| December | 524.33 | 21.35 | 252.67 | 21.27 | 252.67 | 21.23 |
| Annual Sum or Average | 4206.33 | 22.34 | 3502.50 | 22.71 | 2049.33 | 22.67 |
| Minimum of Months | 183.00 | 21.26 | 76.33 | 21.19 | 44.83 | 21.16 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 375.33 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.26 | 376.00 | 21.19 | 376.00 | 21.16 |
| February | 461.17 | 21.53 | 206.33 | 21.39 | 206.33 | 21.32 |
| March | 417.50 | 22.09 | 76.50 | 22.06 | 55.17 | 21.96 |
| April | 300.50 | 22.58 | 153.17 | 22.92 | 44.83 | 22.90 |
| May | 183.00 | 23.31 | 329.17 | 23.71 | 91.67 | 23.72 |
| June | 187.50 | 23.85 | 389.50 | 23.95 | 143.50 | 23.96 |
| July | 247.67 | 23.99 | 533.00 | 23.99 | 247.67 | 23.99 |
| August | 287.00 | 24.00 | 506.00 | 24.00 | 287.00 | 24.00 |
| September | 234.17 | 23.68 | 389.67 | 23.88 | 164.17 | 23.90 |
| October | 382.00 | 22.34 | 157.00 | 22.73 | 74.33 | 22.79 |
| November | 449.67 | 21.94 | 134.83 | 21.96 | 107.83 | 21.90 |
| December | 524.17 | 21.35 | 253.17 | 21.27 | 253.17 | 21.23 |
| Annual Sum or Average | 4207.33 | 22.33 | 3504.33 | 22.70 | 2051.67 | 22.67 |
| Minimum of Months | 183.00 | 21.26 | 76.50 | 21.19 | 44.83 | 21.16 |
| Maximum of Months | 533.00 | 24.00 | 533.00 | 24.00 | 376.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 20.16 | 527.33 | 19.99 | 527.33 | 19.92 |
| February | 635.83 | 20.83 | 378.50 | 20.62 | 358.67 | 20.47 |
| March | 667.67 | 22.54 | 274.00 | 22.91 | 224.50 | 23.05 |
| April | 665.67 | 24.04 | 564.50 | 24.28 | 528.83 | 24.35 |
| May | 724.83 | 25.28 | 712.33 | 25.33 | 697.83 | 25.35 |
| June | 720.00 | 26.01 | 720.00 | 26.01 | 720.00 | 26.01 |
| July | 744.00 | 26.24 | 744.00 | 26.24 | 744.00 | 26.24 |
| August | 744.00 | 26.30 | 744.00 | 26.30 | 744.00 | 26.30 |
| September | 720.00 | 25.45 | 720.00 | 25.45 | 720.00 | 25.45 |
| October | 720.17 | 23.37 | 615.17 | 23.53 | 594.17 | 23.58 |
| November | 704.17 | 22.04 | 272.83 | 22.17 | 267.83 | 22.24 |
| December | 744.00 | 20.81 | 374.83 | 20.69 | 374.83 | 20.63 |
| Annual Sum or Average | 8534.33 | 23.62 | 6647.50 | 23.89 | 6502.00 | 23.99 |
| Minimum of Months | 635.83 | 20.16 | 272.83 | 19.99 | 224.50 | 19.92 |
| Maximum of Months | 744.00 | 26.30 | 744.00 | 26.30 | 744.00 | 26.30 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 18.29 | 658.00 | 18.14 | 658.00 | 18.08 |
| February | 672.00 | 19.50 | 391.67 | 18.93 | 391.67 | 18.67 |
| March | 718.00 | 21.52 | 170.00 | 21.25 | 155.00 | 21.01 |
| April | 531.33 | 22.77 | 295.83 | 23.25 | 169.83 | 23.26 |
| May | 463.50 | 24.73 | 611.50 | 25.02 | 397.00 | 25.04 |
| June | 555.33 | 26.47 | 705.00 | 26.45 | 547.67 | 26.47 |
| July | 743.17 | 26.74 | 744.00 | 26.74 | 743.17 | 26.74 |
| August | 730.83 | 26.92 | 744.00 | 26.91 | 730.83 | 26.92 |
| September | 533.67 | 26.08 | 700.50 | 26.05 | 520.50 | 26.09 |
| October | 486.17 | 23.52 | 397.17 | 24.18 | 236.67 | 24.33 |
| November | 658.50 | 21.93 | 188.33 | 21.78 | 169.83 | 21.63 |
| December | 744.00 | 19.87 | 470.83 | 19.52 | 470.83 | 19.37 |
| Annual Sum or Average | 7580.50 | 23.03 | 6076.83 | 23.36 | 5191.00 | 23.39 |
| Minimum of Months | 463.50 | 18.29 | 170.00 | 18.14 | 155.00 | 18.08 |
| Maximum of Months | 744.00 | 26.92 | 744.00 | 26.91 | 743.17 | 26.92 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.81 | 99.33 | 21.86 | 99.33 | 21.90 |
| February | 627.83 | 22.41 | 191.83 | 22.70 | 168.33 | 22.83 |
| March | 653.67 | 24.13 | 488.00 | 24.34 | 435.00 | 24.42 |
| April | 674.00 | 25.25 | 679.67 | 25.27 | 640.83 | 25.30 |
| May | 743.83 | 25.74 | 744.00 | 25.74 | 743.83 | 25.74 |
| June | 720.00 | 26.03 | 720.00 | 26.03 | 720.00 | 26.03 |
| July | 744.00 | 26.10 | 744.00 | 26.10 | 744.00 | 26.10 |
| August | 744.00 | 26.13 | 744.00 | 26.13 | 744.00 | 26.13 |
| September | 720.00 | 25.81 | 720.00 | 25.81 | 720.00 | 25.81 |
| October | 733.17 | 24.85 | 698.17 | 24.89 | 697.83 | 24.90 |
| November | 661.33 | 23.64 | 490.50 | 23.83 | 464.00 | 23.90 |
| December | 744.00 | 22.40 | 150.83 | 22.58 | 150.83 | 22.70 |
| Annual Sum or Average | 8509.83 | 24.55 | 6470.33 | 24.90 | 6328.00 | 25.04 |
| Minimum of Months | 627.83 | 21.81 | 99.33 | 21.86 | 99.33 | 21.90 |
| Maximum of Months | 744.00 | 26.13 | 744.00 | 26.13 | 744.00 | 26.13 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 28303120.79 | 7473602.46 | 22.17 | 28303120.79 | 0.00 | 0.00 | 0.13 | 26-FEB-17:10 | 0.00 | 01-FEB-00:10 | 649.20 | 26-FEB-17:10 | 649.20 | 26-FEB-17:10 | 0.00 | 26-FEB-16:20 | 169.89 | 26-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 87144184.38 | 22741465.59 | 52.36 | 79672307.06 | 7471877.32 | 0.00 | 0.24 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 | 1280.24 | 30-MAR-16:07 | 1209.52 | 30-MAR-16:07 | 161.08 | 30-MAR-13:00 | 341.03 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.374551E+09 | 98068671.13 | 194.33 | 0.348185E+09 | 26365949.81 | 0.00 | 0.26 | 17-APR-16:08 | 0.00 | 01-APR-00:10 | 1370.17 | 17-APR-16:05 | 1370.17 | 17-APR-16:05 | 241.54 | 23-APR-16:10 | 373.39 | 17-APR-16:05 | 0.00 | 01-APR-00:10 |
| May | 0.127130E+10 | 0.327132E+09 | 460.29 | 0.104425E+10 | 0.227058E+09 | 0.00 | 0.36 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 | 1937.19 | 19-MAY-17:30 | 1799.38 | 19-MAY-17:30 | 451.70 | 07-MAY-17:00 | 525.11 | 19-MAY-17:20 | 0.00 | 01-MAY-00:10 |
| June | 0.325080E+10 | 0.840117E+09 | 685.47 | 0.250813E+10 | 0.742667E+09 | 0.00 | 0.51 | 25-JUN-16:02 | 0.00 | 01-JUN-05:05 | 2849.76 | 25-JUN-16:02 | 2401.14 | 06-JUN-17:05 | 709.62 | 23-JUN-12:00 | 782.86 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.433680E+10 | 0.111539E+10 | 740.00 | 0.318851E+10 | 0.114829E+10 | 0.00 | 0.57 | 08-JUL-16:03 | 0.00 | 29-JUL-05:05 | 3173.71 | 15-JUL-16:40 | 2599.88 | 08-JUL-16:03 | 760.33 | 23-JUL-16:15 | 886.89 | 08-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 0.512279E+10 | 0.129799E+10 | 744.00 | 0.371558E+10 | 0.140721E+10 | 0.00 | 0.58 | 18-AUG-17:20 | 0.06 | 25-AUG-06:00 | 3270.16 | 19-AUG-16:10 | 2758.33 | 18-AUG-17:17 | 1002.68 | 20-AUG-16:10 | 890.02 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.326725E+10 | 0.817062E+09 | 671.43 | 0.254924E+10 | 0.718008E+09 | 0.00 | 0.55 | 07-SEP-16:10 | 0.00 | 14-SEP-04:50 | 3130.23 | 07-SEP-16:10 | 2543.48 | 07-SEP-16:02 | 754.36 | 16-SEP-13:30 | 830.98 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.131415E+10 | 0.328135E+09 | 396.03 | 0.109683E+10 | 0.217315E+09 | 0.00 | 0.50 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 | 2773.52 | 10-OCT-16:02 | 2440.99 | 10-OCT-16:03 | 701.78 | 18-OCT-21:00 | 728.64 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.230512E+09 | 58951461.52 | 144.83 | 0.207167E+09 | 23345394.94 | 0.00 | 0.31 | 05-NOV-16:05 | 0.00 | 01-NOV-00:10 | 1738.46 | 05-NOV-16:05 | 1470.58 | 05-NOV-16:05 | 335.13 | 05-NOV-13:30 | 427.10 | 05-NOV-16:05 | 0.00 | 01-NOV-00:10 |
| December | 7972858.41 | 2030405.39 | 9.33 | 6790189.55 | 1182668.86 | 0.00 | 0.10 | 12-DEC-14:30 | 0.00 | 01-DEC-00:10 | 560.03 | 12-DEC-14:30 | 462.08 | 12-DEC-14:30 | 102.75 | 12-DEC-14:00 | 141.17 | 12-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.192916E+11 | 0.491509E+10 | 4120.24 | 0.147727E+11 | 0.451892E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.512279E+10 | 0.129799E+10 | 744.00 | 0.371558E+10 | 0.140721E+10 | 0.00 | 0.58 | 0.06 | 3270.16 | 2758.33 | 1002.68 | 890.02 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 25938131.32 | 6818887.34 | 16.17 | 22393546.24 | 3544585.07 | 0.00 | 0.17 | 30-MAR-16:30 | 0.00 | 01-MAR-00:10 | 887.55 | 30-MAR-16:30 | 814.94 | 30-MAR-16:30 | 94.24 | 30-MAR-14:10 | 236.83 | 30-MAR-16:30 | 0.00 | 01-MAR-00:10 |
| April | 0.199688E+09 | 52400674.72 | 130.17 | 0.182557E+09 | 17130849.23 | 0.00 | 0.21 | 17-APR-17:00 | 0.00 | 01-APR-00:10 | 1039.26 | 17-APR-17:05 | 1039.26 | 17-APR-17:05 | 207.66 | 23-APR-16:20 | 283.12 | 17-APR-17:00 | 0.00 | 01-APR-00:10 |
| May | 0.112360E+10 | 0.289325E+09 | 441.21 | 0.912586E+09 | 0.211013E+09 | 0.00 | 0.35 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 | 1846.09 | 19-MAY-17:30 | 1696.03 | 19-MAY-17:30 | 411.32 | 07-MAY-17:00 | 500.15 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.323346E+10 | 0.834386E+09 | 686.17 | 0.248708E+10 | 0.746380E+09 | 0.00 | 0.52 | 06-JUN-17:03 | 0.00 | 01-JUN-05:05 | 2783.46 | 06-JUN-17:03 | 2386.46 | 06-JUN-17:17 | 706.38 | 26-JUN-15:10 | 774.73 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.427762E+10 | 0.109894E+10 | 739.83 | 0.313513E+10 | 0.114249E+10 | 0.00 | 0.56 | 15-JUL-16:50 | 0.00 | 29-JUL-05:05 | 3078.94 | 15-JUL-16:50 | 2483.39 | 08-JUL-16:30 | 742.12 | 31-JUL-15:20 | 846.11 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.484888E+10 | 0.122835E+10 | 744.00 | 0.347153E+10 | 0.137735E+10 | 0.00 | 0.57 | 01-AUG-17:00 | 0.05 | 25-AUG-06:00 | 3098.80 | 03-AUG-16:30 | 2566.77 | 18-AUG-17:17 | 955.19 | 20-AUG-16:10 | 869.06 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.277248E+10 | 0.694556E+09 | 662.03 | 0.210593E+10 | 0.666543E+09 | 0.00 | 0.50 | 07-SEP-16:17 | 0.00 | 14-SEP-03:30 | 2782.81 | 07-SEP-16:30 | 2192.40 | 07-SEP-16:30 | 684.85 | 16-SEP-13:30 | 740.02 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.728624E+09 | 0.181617E+09 | 286.07 | 0.558846E+09 | 0.169778E+09 | 0.00 | 0.37 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 | 1966.09 | 10-OCT-16:02 | 1643.44 | 10-OCT-16:17 | 671.36 | 18-OCT-21:00 | 524.63 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 24206913.21 | 6045500.56 | 23.33 | 18645715.76 | 5561197.45 | 0.00 | 0.19 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1043.59 | 05-NOV-16:10 | 835.78 | 05-NOV-16:10 | 217.77 | 05-NOV-15:10 | 259.09 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.172345E+11 | 0.439244E+10 | 3728.98 | 0.128947E+11 | 0.433979E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.484888E+10 | 0.122835E+10 | 744.00 | 0.347153E+10 | 0.137735E+10 | 0.00 | 0.57 | 0.05 | 3098.80 | 2566.77 | 955.19 | 869.06 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 68693347.90 | 17934352.70 | 29.08 | 68693347.90 | -0.0 | 0.00 | 0.25 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 | 1381.53 | 28-FEB-15:00 | 1381.53 | 28-FEB-15:00 | 0.00 | 21-FEB-15:00 | 359.20 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.259575E+09 | 66167339.67 | 92.19 | 0.229488E+09 | 30086604.10 | 0.00 | 0.98 | 31-MAR-08:62 | 0.00 | 01-MAR-00:10 | 6676.03 | 31-MAR-08:62 | 5050.29 | 31-MAR-08:62 | 1625.73 | 31-MAR-08:62 | 1433.71 | 31-MAR-08:62 | 0.00 | 01-MAR-00:10 |
| April | 0.562982E+09 | 0.143655E+09 | 133.30 | 0.515437E+09 | 47545044.88 | 0.00 | 1.00 | 17-APR-08:62 | 0.00 | 01-APR-00:10 | 6720.34 | 19-APR-08:62 | 6447.96 | 17-APR-08:62 | 1122.07 | 19-APR-08:62 | 1455.30 | 19-APR-08:62 | 0.00 | 01-APR-00:10 |
| May | 0.129125E+10 | 0.322470E+09 | 191.15 | 0.107608E+10 | 0.215167E+09 | 0.00 | 1.00 | 05-MAY-08:62 | 0.00 | 01-MAY-00:10 | 7083.89 | 26-MAY-08:62 | 6115.73 | 17-MAY-08:62 | 2649.10 | 26-MAY-08:62 | 1472.84 | 30-MAY-08:62 | 0.00 | 01-MAY-00:10 |
| June | 0.253013E+10 | 0.631070E+09 | 223.59 | 0.201090E+10 | 0.519229E+09 | 0.00 | 1.00 | 01-JUN-08:62 | 0.00 | 01-JUN-00:10 | 7354.99 | 26-JUN-07:02 | 6400.20 | 09-JUN-08:62 | 3140.38 | 23-JUN-07:03 | 1522.71 | 22-JUN-08:62 | 0.00 | 01-JUN-00:10 |
| July | 0.290235E+10 | 0.718460E+09 | 277.24 | 0.223785E+10 | 0.664507E+09 | 0.00 | 1.00 | 03-JUL-07:02 | 0.00 | 01-JUL-00:10 | 7455.83 | 27-JUL-07:02 | 5577.95 | 03-JUL-07:02 | 3709.31 | 27-JUL-07:04 | 1547.52 | 14-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.359770E+10 | 0.878902E+09 | 316.91 | 0.272295E+10 | 0.874756E+09 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 7501.16 | 24-AUG-07:02 | 5115.95 | 25-AUG-08:62 | 3787.44 | 24-AUG-07:05 | 1552.51 | 10-AUG-08:15 | 0.00 | 01-AUG-00:10 |
| September | 0.229315E+10 | 0.553619E+09 | 213.66 | 0.188975E+10 | 0.403402E+09 | 0.00 | 1.00 | 01-SEP-07:03 | 0.00 | 01-SEP-00:10 | 7345.33 | 07-SEP-07:02 | 6164.02 | 15-SEP-08:62 | 2974.29 | 07-SEP-07:03 | 1491.80 | 07-SEP-08:15 | 0.00 | 01-SEP-00:10 |
| October | 0.117779E+10 | 0.287226E+09 | 161.85 | 0.100988E+10 | 0.167903E+09 | 0.00 | 1.00 | 02-OCT-08:62 | 0.00 | 01-OCT-00:10 | 7304.83 | 19-OCT-07:03 | 6270.95 | 12-OCT-08:62 | 3292.39 | 19-OCT-07:03 | 1462.15 | 02-OCT-08:62 | 0.00 | 01-OCT-00:10 |
| November | 0.401348E+09 | 0.102287E+09 | 108.86 | 0.377737E+09 | 23610944.58 | 0.00 | 0.67 | 06-NOV-09:03 | 0.00 | 01-NOV-00:10 | 4050.71 | 06-NOV-09:03 | 3869.76 | 06-NOV-09:03 | 612.84 | 03-NOV-08:63 | 955.61 | 06-NOV-09:03 | 0.00 | 01-NOV-00:10 |
| December | 75661329.10 | 18992022.77 | 26.44 | 62338809.83 | 13322519.27 | 0.00 | 0.63 | 13-DEC-09:03 | 0.00 | 01-DEC-00:10 | 4011.14 | 13-DEC-09:03 | 2969.13 | 13-DEC-09:03 | 1042.01 | 13-DEC-09:03 | 916.18 | 13-DEC-09:03 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.151606E+11 | 0.374078E+10 | 1774.28 | 0.122011E+11 | 0.295953E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.359770E+10 | 0.878902E+09 | 316.91 | 0.272295E+10 | 0.874756E+09 | 0.00 | 1.00 | 0.00 | 7501.16 | 6447.96 | 3787.44 | 1552.51 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 15962582.59 | 4221828.02 | 13.67 | 13744568.16 | 2218014.43 | 0.00 | 0.13 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 | 624.94 | 30-MAR-16:07 | 572.19 | 30-MAR-16:07 | 83.37 | 30-MAR-13:30 | 168.71 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.195232E+09 | 51268018.13 | 131.44 | 0.178344E+09 | 16887978.96 | 0.00 | 0.17 | 19-APR-16:07 | 0.00 | 01-APR-00:10 | 855.20 | 19-APR-16:07 | 803.95 | 17-APR-16:08 | 170.01 | 23-APR-16:10 | 225.58 | 19-APR-16:07 | 0.00 | 01-APR-00:10 |
| May | 0.115196E+10 | 0.295838E+09 | 448.81 | 0.934645E+09 | 0.217314E+09 | 0.00 | 0.33 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 1662.06 | 31-MAY-16:03 | 1390.85 | 19-MAY-16:10 | 452.22 | 31-MAY-09:50 | 443.17 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.328537E+10 | 0.844789E+09 | 689.79 | 0.253116E+10 | 0.754207E+09 | 0.00 | 0.50 | 06-JUN-17:00 | 0.00 | 01-JUN-05:05 | 2528.23 | 29-JUN-17:10 | 2139.88 | 06-JUN-17:05 | 774.22 | 29-JUN-10:00 | 703.29 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.434475E+10 | 0.111111E+10 | 739.67 | 0.318812E+10 | 0.115663E+10 | 0.00 | 0.55 | 08-JUL-16:01 | 0.00 | 29-JUL-05:05 | 2798.59 | 08-JUL-11:00 | 2302.82 | 08-JUL-16:01 | 788.41 | 26-JUL-10:30 | 789.07 | 08-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 0.485364E+10 | 0.122528E+10 | 744.00 | 0.347474E+10 | 0.137889E+10 | 0.00 | 0.56 | 01-AUG-17:00 | 0.05 | 25-AUG-06:00 | 2869.27 | 19-AUG-16:10 | 2317.42 | 01-AUG-17:00 | 896.10 | 20-AUG-16:10 | 795.60 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.278704E+10 | 0.696448E+09 | 663.74 | 0.211759E+10 | 0.669447E+09 | 0.00 | 0.49 | 07-SEP-16:10 | 0.00 | 14-SEP-03:20 | 2539.96 | 07-SEP-16:10 | 1988.78 | 07-SEP-16:08 | 671.95 | 16-SEP-13:00 | 678.48 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.724905E+09 | 0.180298E+09 | 298.37 | 0.552737E+09 | 0.172169E+09 | 0.00 | 0.35 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 1871.85 | 18-OCT-16:05 | 1420.14 | 10-OCT-16:10 | 674.20 | 18-OCT-21:00 | 457.96 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 18520826.57 | 4606262.65 | 16.67 | 13809909.07 | 4710917.50 | 0.00 | 0.16 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 824.24 | 05-NOV-16:10 | 650.29 | 05-NOV-16:10 | 181.90 | 05-NOV-15:10 | 205.12 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.173774E+11 | 0.441386E+10 | 3746.17 | 0.130049E+11 | 0.437247E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.485364E+10 | 0.122528E+10 | 744.00 | 0.347474E+10 | 0.137889E+10 | 0.00 | 0.56 | 0.05 | 2869.27 | 2317.42 | 896.10 | 795.60 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 17444967.27 | 4589761.92 | 15.83 | 14896446.18 | 2548521.09 | 0.00 | 0.13 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 | 581.13 | 30-MAR-16:07 | 526.29 | 30-MAR-16:07 | 75.71 | 30-MAR-14:10 | 156.61 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.214139E+09 | 55608950.98 | 160.33 | 0.188617E+09 | 25521296.79 | 0.00 | 0.19 | 19-APR-16:07 | 0.00 | 01-APR-00:10 | 828.25 | 19-APR-16:07 | 753.56 | 19-APR-16:07 | 182.02 | 23-APR-16:10 | 217.98 | 19-APR-16:07 | 0.00 | 01-APR-00:10 |
| May | 0.111288E+10 | 0.284835E+09 | 520.99 | 0.891652E+09 | 0.221227E+09 | 0.00 | 0.32 | 30-MAY-18:00 | 0.00 | 01-MAY-00:10 | 1492.21 | 30-MAY-18:00 | 1209.31 | 19-MAY-17:30 | 387.54 | 07-MAY-17:00 | 383.52 | 30-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.289717E+10 | 0.744502E+09 | 702.51 | 0.221618E+10 | 0.680995E+09 | 0.00 | 0.46 | 06-JUN-17:03 | 0.00 | 02-JUN-05:40 | 2141.34 | 23-JUN-17:00 | 1760.46 | 06-JUN-17:10 | 613.03 | 29-JUN-10:00 | 582.58 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.377706E+10 | 0.965792E+09 | 744.00 | 0.273493E+10 | 0.104213E+10 | 0.00 | 0.51 | 15-JUL-17:05 | 0.02 | 29-JUL-07:04 | 2391.46 | 15-JUL-17:05 | 1894.23 | 08-JUL-16:03 | 648.71 | 26-JUL-11:00 | 663.76 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.418952E+10 | 0.105777E+10 | 744.00 | 0.296325E+10 | 0.122627E+10 | 0.00 | 0.51 | 03-AUG-17:05 | 0.08 | 25-AUG-06:00 | 2360.17 | 03-AUG-17:05 | 1878.89 | 01-AUG-17:00 | 765.62 | 20-AUG-16:10 | 657.41 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.248599E+10 | 0.620900E+09 | 686.64 | 0.187033E+10 | 0.615659E+09 | 0.00 | 0.45 | 07-SEP-16:10 | 0.00 | 14-SEP-08:20 | 2098.88 | 07-SEP-16:10 | 1619.26 | 07-SEP-16:08 | 597.75 | 16-SEP-18:00 | 563.53 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.684745E+09 | 0.170262E+09 | 330.44 | 0.520950E+09 | 0.163795E+09 | 0.00 | 0.34 | 18-OCT-16:05 | 0.00 | 01-OCT-05:05 | 1666.20 | 18-OCT-16:05 | 1201.94 | 10-OCT-16:03 | 630.67 | 18-OCT-21:00 | 401.81 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 24985685.75 | 6220583.60 | 29.64 | 18729601.45 | 6256084.30 | 0.00 | 0.18 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 832.36 | 05-NOV-16:10 | 658.30 | 05-NOV-16:10 | 180.27 | 05-NOV-15:10 | 206.64 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.154039E+11 | 0.391048E+10 | 3934.39 | 0.114195E+11 | 0.398441E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.418952E+10 | 0.105777E+10 | 744.00 | 0.296325E+10 | 0.122627E+10 | 0.00 | 0.51 | 0.08 | 2391.46 | 1894.23 | 765.62 | 663.76 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 17238868.80 | 4536475.09 | 15.67 | 14718238.88 | 2520629.92 | 0.00 | 0.13 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 | 577.42 | 30-MAR-16:07 | 522.84 | 30-MAR-16:07 | 75.57 | 30-MAR-14:10 | 155.63 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.214787E+09 | 55783973.52 | 160.17 | 0.189306E+09 | 25480977.43 | 0.00 | 0.19 | 19-APR-16:07 | 0.00 | 01-APR-00:10 | 829.66 | 19-APR-16:07 | 755.03 | 19-APR-16:20 | 181.67 | 23-APR-16:10 | 218.34 | 19-APR-16:07 | 0.00 | 01-APR-00:10 |
| May | 0.111584E+10 | 0.285585E+09 | 521.74 | 0.894298E+09 | 0.221546E+09 | 0.00 | 0.32 | 30-MAY-18:00 | 0.00 | 01-MAY-00:10 | 1491.90 | 30-MAY-18:00 | 1206.96 | 19-MAY-17:30 | 388.56 | 07-MAY-17:00 | 383.42 | 30-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.290027E+10 | 0.745254E+09 | 702.51 | 0.221883E+10 | 0.681439E+09 | 0.00 | 0.46 | 06-JUN-17:03 | 0.00 | 02-JUN-05:40 | 2136.93 | 23-JUN-17:00 | 1758.48 | 06-JUN-17:10 | 614.83 | 29-JUN-10:00 | 582.01 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.378068E+10 | 0.966632E+09 | 744.00 | 0.273782E+10 | 0.104285E+10 | 0.00 | 0.51 | 15-JUL-17:05 | 0.02 | 29-JUL-07:04 | 2387.18 | 15-JUL-17:05 | 1894.05 | 08-JUL-16:03 | 650.18 | 26-JUL-11:00 | 663.57 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.419023E+10 | 0.105790E+10 | 744.00 | 0.296377E+10 | 0.122646E+10 | 0.00 | 0.51 | 03-AUG-17:05 | 0.08 | 25-AUG-06:00 | 2357.20 | 03-AUG-17:05 | 1877.02 | 01-AUG-17:00 | 764.41 | 20-AUG-16:10 | 656.73 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.248709E+10 | 0.621151E+09 | 686.69 | 0.187121E+10 | 0.615880E+09 | 0.00 | 0.45 | 07-SEP-16:10 | 0.00 | 14-SEP-08:20 | 2097.59 | 07-SEP-16:10 | 1618.42 | 07-SEP-16:08 | 597.60 | 16-SEP-18:00 | 563.17 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.687304E+09 | 0.170904E+09 | 331.11 | 0.523202E+09 | 0.164102E+09 | 0.00 | 0.34 | 18-OCT-16:05 | 0.00 | 01-OCT-05:05 | 1667.58 | 18-OCT-16:05 | 1200.91 | 10-OCT-16:03 | 631.17 | 18-OCT-21:00 | 402.12 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 24661950.69 | 6139573.86 | 29.14 | 18477177.88 | 6184772.81 | 0.00 | 0.18 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 827.33 | 05-NOV-16:10 | 654.04 | 05-NOV-16:10 | 179.59 | 05-NOV-15:10 | 205.41 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.154181E+11 | 0.391389E+10 | 3935.02 | 0.114316E+11 | 0.398647E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.419023E+10 | 0.105790E+10 | 744.00 | 0.296377E+10 | 0.122646E+10 | 0.00 | 0.51 | 0.08 | 2387.18 | 1894.05 | 764.41 | 663.57 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 35468038.47 | 9350848.06 | 29.00 | 35468038.47 | 0.00 | 0.00 | 0.14 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 609.67 | 28-FEB-15:10 | 609.67 | 28-FEB-15:10 | 0.00 | 28-FEB-14:10 | 160.73 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 97120305.04 | 25288827.98 | 73.53 | 89156474.33 | 7963830.71 | 0.00 | 0.22 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 | 984.82 | 30-MAR-16:07 | 926.01 | 30-MAR-16:07 | 159.10 | 30-MAR-12:50 | 263.21 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.414707E+09 | 0.107717E+09 | 246.03 | 0.376282E+09 | 38424890.26 | 0.00 | 0.25 | 17-APR-16:10 | 0.00 | 01-APR-00:10 | 1108.80 | 17-APR-16:10 | 1108.80 | 17-APR-16:10 | 237.29 | 23-APR-14:00 | 302.88 | 17-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.128626E+10 | 0.329113E+09 | 548.15 | 0.104471E+10 | 0.241550E+09 | 0.00 | 0.32 | 29-MAY-17:07 | 0.00 | 01-MAY-00:10 | 1525.54 | 30-MAY-18:00 | 1342.59 | 19-MAY-16:03 | 428.86 | 07-MAY-17:00 | 408.21 | 29-MAY-16:40 | 0.00 | 01-MAY-00:10 |
| June | 0.292593E+10 | 0.753458E+09 | 700.44 | 0.224670E+10 | 0.679234E+09 | 0.00 | 0.46 | 25-JUN-16:02 | 0.00 | 02-JUN-05:40 | 2221.35 | 25-JUN-16:02 | 1780.33 | 06-JUN-17:08 | 613.90 | 23-JUN-12:00 | 613.91 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.385300E+10 | 0.986938E+09 | 744.00 | 0.280193E+10 | 0.105107E+10 | 0.00 | 0.52 | 08-JUL-16:03 | 0.02 | 29-JUL-05:05 | 2469.46 | 15-JUL-16:40 | 2016.68 | 08-JUL-16:03 | 666.56 | 26-JUL-11:50 | 705.30 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.448502E+10 | 0.113337E+10 | 744.00 | 0.322431E+10 | 0.126071E+10 | 0.00 | 0.54 | 19-AUG-16:10 | 0.09 | 25-AUG-06:00 | 2626.03 | 19-AUG-16:10 | 2076.26 | 18-AUG-16:05 | 815.89 | 20-AUG-16:10 | 705.52 | 19-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.300877E+10 | 0.750456E+09 | 698.38 | 0.233670E+10 | 0.672069E+09 | 0.00 | 0.51 | 07-SEP-16:10 | 0.00 | 14-SEP-08:20 | 2462.55 | 07-SEP-16:10 | 1975.33 | 07-SEP-16:08 | 654.39 | 16-SEP-13:30 | 657.75 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.134580E+10 | 0.336054E+09 | 490.83 | 0.113185E+10 | 0.213943E+09 | 0.00 | 0.47 | 10-OCT-16:03 | 0.00 | 01-OCT-05:05 | 2281.75 | 11-OCT-14:10 | 1984.56 | 10-OCT-16:03 | 663.30 | 18-OCT-21:00 | 597.56 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.328176E+09 | 83920426.13 | 229.22 | 0.295999E+09 | 32176821.05 | 0.00 | 0.31 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1516.35 | 05-NOV-16:10 | 1275.66 | 05-NOV-16:10 | 317.31 | 05-NOV-13:30 | 372.05 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 14755244.41 | 3748817.58 | 17.67 | 12546246.20 | 2208998.21 | 0.00 | 0.14 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 661.52 | 12-DEC-14:00 | 544.59 | 12-DEC-14:00 | 116.93 | 12-DEC-14:00 | 165.75 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.177950E+11 | 0.451942E+10 | 4521.25 | 0.135957E+11 | 0.419935E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.448502E+10 | 0.113337E+10 | 744.00 | 0.322431E+10 | 0.126071E+10 | 0.00 | 0.54 | 0.09 | 2626.03 | 2076.26 | 815.89 | 705.52 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 37867076.46 | 9977768.93 | 30.00 | 37867076.46 | -0.0 | 0.00 | 0.14 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 638.78 | 28-FEB-15:10 | 638.78 | 28-FEB-15:10 | 0.00 | 26-FEB-14:10 | 168.27 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.109417E+09 | 28458479.80 | 82.92 | 0.100440E+09 | 8976829.09 | 0.00 | 0.22 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 | 1022.43 | 30-MAR-16:07 | 962.50 | 30-MAR-16:07 | 166.15 | 30-MAR-12:50 | 273.05 | 30-MAR-16:07 | 0.00 | 01-MAR-00:10 |
| April | 0.461035E+09 | 0.119526E+09 | 267.22 | 0.417797E+09 | 43237562.01 | 0.00 | 0.26 | 17-APR-16:05 | 0.00 | 01-APR-00:10 | 1166.58 | 17-APR-16:05 | 1166.58 | 17-APR-16:05 | 247.18 | 23-APR-14:00 | 318.14 | 17-APR-16:05 | 0.00 | 01-APR-00:10 |
| May | 0.141886E+10 | 0.362332E+09 | 573.48 | 0.115596E+10 | 0.262904E+09 | 0.00 | 0.33 | 29-MAY-16:40 | 0.00 | 01-MAY-00:10 | 1599.33 | 30-MAY-18:00 | 1398.27 | 19-MAY-16:05 | 448.22 | 07-MAY-17:00 | 426.44 | 29-MAY-16:40 | 0.00 | 01-MAY-00:10 |
| June | 0.317296E+10 | 0.815004E+09 | 706.67 | 0.245848E+10 | 0.714480E+09 | 0.00 | 0.49 | 25-JUN-16:02 | 0.00 | 02-JUN-05:40 | 2364.64 | 25-JUN-16:02 | 1900.47 | 25-JUN-16:20 | 620.99 | 23-JUN-12:00 | 651.56 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.418443E+10 | 0.106872E+10 | 744.00 | 0.308102E+10 | 0.110341E+10 | 0.00 | 0.55 | 08-JUL-16:01 | 0.03 | 29-JUL-05:05 | 2611.02 | 15-JUL-16:50 | 2158.62 | 08-JUL-16:01 | 678.09 | 26-JUL-11:00 | 745.87 | 08-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 0.482851E+10 | 0.121708E+10 | 744.00 | 0.351638E+10 | 0.131214E+10 | 0.00 | 0.56 | 19-AUG-16:10 | 0.11 | 25-AUG-06:00 | 2785.08 | 19-AUG-16:10 | 2193.69 | 19-AUG-16:10 | 836.48 | 20-AUG-16:10 | 745.72 | 19-AUG-16:10 | 0.00 | 01-AUG-00:10 |
| September | 0.327506E+10 | 0.815243E+09 | 705.62 | 0.256667E+10 | 0.708388E+09 | 0.00 | 0.52 | 07-SEP-16:10 | 0.00 | 22-SEP-06:00 | 2547.76 | 07-SEP-16:10 | 2054.55 | 07-SEP-16:08 | 670.26 | 16-SEP-13:30 | 679.46 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.146422E+10 | 0.365426E+09 | 513.03 | 0.123807E+10 | 0.226143E+09 | 0.00 | 0.49 | 10-OCT-16:03 | 0.00 | 01-OCT-05:05 | 2358.81 | 11-OCT-14:10 | 2054.51 | 10-OCT-16:03 | 689.83 | 18-OCT-21:00 | 615.88 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.360722E+09 | 92197996.27 | 240.67 | 0.325573E+09 | 35149018.77 | 0.00 | 0.32 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1567.96 | 05-NOV-16:10 | 1323.58 | 05-NOV-16:10 | 324.59 | 05-NOV-13:30 | 384.44 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 15321975.63 | 3890011.25 | 17.33 | 12974708.54 | 2347267.10 | 0.00 | 0.14 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 676.30 | 12-DEC-14:00 | 556.83 | 12-DEC-14:00 | 119.47 | 12-DEC-14:00 | 169.42 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.193284E+11 | 0.489785E+10 | 4624.93 | 0.149112E+11 | 0.441717E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.482851E+10 | 0.121708E+10 | 744.00 | 0.351638E+10 | 0.131214E+10 | 0.00 | 0.56 | 0.11 | 2785.08 | 2193.69 | 836.48 | 745.87 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.248217E+09 | 64831072.35 | 53.42 | 0.248217E+09 | 0.00 | 0.00 | 0.25 | 26-FEB-16:30 | 0.00 | 01-FEB-00:10 | 3124.27 | 26-FEB-16:30 | 3124.27 | 26-FEB-16:30 | 0.00 | 28-FEB-16:20 | 805.41 | 26-FEB-16:30 | 0.00 | 01-FEB-00:10 |
| March | 0.101478E+10 | 0.260537E+09 | 205.72 | 0.940535E+09 | 74247979.26 | 0.00 | 0.38 | 30-MAR-16:20 | 0.00 | 01-MAR-00:10 | 4964.34 | 30-MAR-16:20 | 4765.22 | 30-MAR-16:07 | 654.21 | 30-MAR-11:50 | 1293.76 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.266013E+10 | 0.681153E+09 | 425.99 | 0.242743E+10 | 0.232696E+09 | 0.00 | 0.37 | 15-APR-16:03 | 0.00 | 01-APR-00:10 | 4709.40 | 15-APR-16:10 | 4709.40 | 15-APR-16:10 | 981.78 | 04-APR-13:30 | 1256.78 | 17-APR-16:08 | 0.00 | 01-APR-00:10 |
| May | 0.513146E+10 | 0.130529E+10 | 642.57 | 0.429949E+10 | 0.831967E+09 | 0.00 | 0.43 | 19-MAY-17:30 | 0.00 | 01-MAY-04:40 | 5508.70 | 06-MAY-16:03 | 5149.59 | 19-MAY-17:30 | 1271.27 | 07-MAY-17:00 | 1476.57 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.843560E+10 | 0.217630E+10 | 699.18 | 0.661808E+10 | 0.181752E+10 | 0.00 | 0.53 | 06-JUN-17:05 | 0.00 | 02-JUN-05:40 | 7011.67 | 25-JUN-16:02 | 6016.43 | 06-JUN-17:05 | 1663.92 | 26-JUN-15:10 | 1926.00 | 06-JUN-17:05 | 0.00 | 01-JUN-00:10 |
| July | 0.101979E+11 | 0.262721E+10 | 743.17 | 0.755264E+10 | 0.264527E+10 | 0.00 | 0.56 | 15-JUL-16:30 | 0.00 | 29-JUL-05:05 | 7504.44 | 15-JUL-16:30 | 6049.65 | 08-JUL-16:03 | 1788.62 | 23-JUL-16:15 | 2053.28 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.113107E+11 | 0.287869E+10 | 744.00 | 0.819083E+10 | 0.311985E+10 | 0.00 | 0.57 | 01-AUG-17:00 | 0.04 | 25-AUG-06:00 | 7510.67 | 01-AUG-17:10 | 6301.88 | 01-AUG-17:00 | 2327.33 | 20-AUG-16:10 | 2109.19 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.681062E+10 | 0.171149E+10 | 658.87 | 0.529513E+10 | 0.151549E+10 | 0.00 | 0.52 | 07-SEP-16:10 | 0.00 | 14-SEP-03:20 | 7004.19 | 07-SEP-16:10 | 5677.72 | 07-SEP-16:03 | 1694.61 | 16-SEP-13:30 | 1869.11 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.272570E+10 | 0.681842E+09 | 357.91 | 0.226528E+10 | 0.460414E+09 | 0.00 | 0.48 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 | 6298.14 | 10-OCT-16:03 | 5554.41 | 10-OCT-16:03 | 1611.40 | 18-OCT-13:10 | 1661.35 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.495426E+09 | 0.126529E+09 | 132.26 | 0.442816E+09 | 52610420.27 | 0.00 | 0.32 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 4216.30 | 05-NOV-16:10 | 3620.47 | 05-NOV-16:10 | 796.55 | 05-NOV-13:30 | 1037.43 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 54828994.73 | 13978792.72 | 22.17 | 47503459.21 | 7325535.52 | 0.00 | 0.16 | 12-DEC-14:30 | 0.00 | 01-DEC-00:10 | 2084.49 | 12-DEC-14:30 | 1748.62 | 12-DEC-14:30 | 361.48 | 12-DEC-14:00 | 522.34 | 12-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.490853E+11 | 0.125279E+11 | 4685.26 | 0.383280E+11 | 0.107574E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.113107E+11 | 0.287869E+10 | 744.00 | 0.819083E+10 | 0.311985E+10 | 0.00 | 0.57 | 0.04 | 7510.67 | 6301.88 | 2327.33 | 2109.19 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 29296878.85 | 7751188.91 | 14.17 | 29296878.85 | 0.00 | 0.00 | 0.11 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 | 1279.08 | 28-FEB-17:10 | 1279.08 | 28-FEB-17:10 | 0.00 | 28-FEB-15:00 | 335.09 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.440248E+09 | 0.113115E+09 | 105.75 | 0.393280E+09 | 46967973.70 | 0.00 | 0.32 | 30-MAR-16:30 | 0.00 | 01-MAR-00:10 | 4083.28 | 30-MAR-16:40 | 3861.95 | 30-MAR-16:30 | 509.74 | 30-MAR-12:00 | 1066.96 | 30-MAR-16:30 | 0.00 | 01-MAR-00:10 |
| April | 0.199849E+10 | 0.512549E+09 | 377.01 | 0.179358E+10 | 0.204909E+09 | 0.00 | 0.32 | 17-APR-17:05 | 0.00 | 01-APR-00:10 | 3971.80 | 17-APR-17:05 | 3971.80 | 17-APR-17:05 | 878.29 | 04-APR-15:10 | 1059.95 | 17-APR-17:00 | 0.00 | 01-APR-00:10 |
| May | 0.477525E+10 | 0.121511E+10 | 635.45 | 0.397309E+10 | 0.802160E+09 | 0.00 | 0.42 | 19-MAY-17:30 | 0.00 | 01-MAY-02:70 | 5295.15 | 19-MAY-17:30 | 4918.18 | 19-MAY-17:30 | 1189.63 | 07-MAY-17:00 | 1421.67 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.837661E+10 | 0.215858E+10 | 702.41 | 0.655710E+10 | 0.181951E+10 | 0.00 | 0.54 | 06-JUN-17:05 | 0.00 | 02-JUN-05:40 | 6925.21 | 06-JUN-17:05 | 5977.33 | 06-JUN-17:17 | 1678.24 | 26-JUN-15:10 | 1924.75 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.100402E+11 | 0.258445E+10 | 742.62 | 0.741498E+10 | 0.262519E+10 | 0.00 | 0.55 | 15-JUL-16:40 | 0.00 | 29-JUL-05:05 | 7258.13 | 15-JUL-16:40 | 5775.74 | 21-JUL-17:50 | 1752.40 | 31-JUL-15:20 | 1978.69 | 15-JUL-16:40 | 0.00 | 01-JUL-00:10 |
| August | 0.107052E+11 | 0.272409E+10 | 744.00 | 0.765473E+10 | 0.305051E+10 | 0.00 | 0.57 | 01-AUG-17:00 | 0.04 | 25-AUG-06:00 | 7324.95 | 01-AUG-17:00 | 6080.09 | 01-AUG-17:00 | 2219.20 | 20-AUG-16:10 | 2059.58 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.574552E+10 | 0.144600E+10 | 648.37 | 0.434366E+10 | 0.140186E+10 | 0.00 | 0.47 | 07-SEP-16:13 | 0.00 | 14-SEP-01:50 | 6181.86 | 07-SEP-16:30 | 4855.49 | 07-SEP-16:30 | 1529.85 | 16-SEP-13:30 | 1652.99 | 07-SEP-16:13 | 0.00 | 01-SEP-00:10 |
| October | 0.149020E+10 | 0.371701E+09 | 258.37 | 0.112722E+10 | 0.362980E+09 | 0.00 | 0.35 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 | 4488.04 | 10-OCT-16:02 | 3766.45 | 10-OCT-16:17 | 1560.69 | 18-OCT-13:10 | 1201.38 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 62734077.27 | 15619228.62 | 23.36 | 47802875.78 | 14931201.49 | 0.00 | 0.20 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 2600.03 | 05-NOV-16:10 | 2121.57 | 05-NOV-16:10 | 520.77 | 05-NOV-15:10 | 646.54 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.436638E+11 | 0.111490E+11 | 4251.52 | 0.333347E+11 | 0.103290E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.107052E+11 | 0.272409E+10 | 744.00 | 0.765473E+10 | 0.305051E+10 | 0.00 | 0.57 | 0.04 | 7324.95 | 6080.09 | 2219.20 | 2059.58 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.260713E+09 | 68082170.72 | 54.58 | 0.260713E+09 | 0.00 | 0.00 | 0.24 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 | 2767.54 | 26-FEB-15:00 | 2767.54 | 26-FEB-15:00 | 0.00 | 26-FEB-16:20 | 722.90 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.925755E+09 | 0.237513E+09 | 206.96 | 0.853360E+09 | 72394634.63 | 0.00 | 0.35 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 | 4284.13 | 30-MAR-14:10 | 4014.06 | 30-MAR-16:10 | 710.74 | 30-MAR-11:40 | 1120.65 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
| April | 0.262961E+10 | 0.672582E+09 | 435.81 | 0.240006E+10 | 0.229547E+09 | 0.00 | 0.35 | 16-APR-14:00 | 0.00 | 01-APR-00:10 | 4144.17 | 16-APR-14:00 | 4144.17 | 16-APR-14:00 | 970.02 | 04-APR-13:30 | 1115.66 | 16-APR-14:00 | 0.00 | 01-APR-00:10 |
| May | 0.521151E+10 | 0.132172E+10 | 648.84 | 0.436591E+10 | 0.845599E+09 | 0.00 | 0.41 | 30-MAY-15:10 | 0.00 | 01-MAY-03:40 | 4985.61 | 30-MAY-15:10 | 4360.97 | 19-MAY-16:10 | 1293.97 | 07-MAY-17:00 | 1333.82 | 30-MAY-14:30 | 0.00 | 01-MAY-00:10 |
| June | 0.855267E+10 | 0.219763E+10 | 705.08 | 0.671776E+10 | 0.183491E+10 | 0.00 | 0.52 | 06-JUN-15:10 | 0.00 | 02-JUN-05:40 | 6368.67 | 28-JUN-15:00 | 5309.90 | 06-JUN-15:10 | 1810.83 | 29-JUN-10:00 | 1765.63 | 06-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.103399E+11 | 0.265060E+10 | 742.64 | 0.766218E+10 | 0.267768E+10 | 0.00 | 0.54 | 08-JUL-16:03 | 0.00 | 29-JUL-05:05 | 6774.07 | 22-JUL-11:30 | 5529.26 | 08-JUL-16:03 | 1857.36 | 01-JUL-11:00 | 1888.55 | 08-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.113203E+11 | 0.286980E+10 | 744.00 | 0.819593E+10 | 0.312441E+10 | 0.00 | 0.56 | 19-AUG-14:00 | 0.04 | 25-AUG-06:00 | 7024.39 | 19-AUG-12:00 | 5681.35 | 19-AUG-14:00 | 2181.61 | 20-AUG-16:10 | 1928.95 | 19-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.684355E+10 | 0.171435E+10 | 660.75 | 0.532102E+10 | 0.152253E+10 | 0.00 | 0.53 | 06-SEP-13:00 | 0.00 | 14-SEP-03:00 | 6727.76 | 06-SEP-13:00 | 5191.57 | 07-SEP-15:10 | 1661.45 | 16-SEP-13:30 | 1768.75 | 06-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.274128E+10 | 0.684669E+09 | 371.10 | 0.227706E+10 | 0.464223E+09 | 0.00 | 0.46 | 10-OCT-14:00 | 0.00 | 01-OCT-00:10 | 5868.92 | 11-OCT-14:10 | 4953.35 | 10-OCT-14:10 | 1628.21 | 18-OCT-12:40 | 1507.86 | 10-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.453027E+09 | 0.115781E+09 | 135.83 | 0.404519E+09 | 48507897.60 | 0.00 | 0.29 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 | 3603.32 | 05-NOV-15:20 | 3047.99 | 05-NOV-16:10 | 760.47 | 05-NOV-13:30 | 887.69 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 |
| December | 49444543.06 | 12563300.49 | 22.00 | 42176357.84 | 7268185.22 | 0.00 | 0.16 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2011.09 | 12-DEC-14:00 | 1662.74 | 12-DEC-14:00 | 348.35 | 12-DEC-14:00 | 502.44 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.493278E+11 | 0.125453E+11 | 4727.59 | 0.385007E+11 | 0.108271E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.113203E+11 | 0.286980E+10 | 744.00 | 0.819593E+10 | 0.312441E+10 | 0.00 | 0.56 | 0.04 | 7024.39 | 5681.35 | 2181.61 | 1928.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 24628179.78 | 6518368.93 | 13.17 | 24628179.78 | 0.00 | 0.00 | 0.09 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 | 1054.22 | 28-FEB-17:05 | 1054.22 | 28-FEB-17:05 | 0.00 | 28-FEB-14:10 | 280.27 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.377963E+09 | 97044797.73 | 96.00 | 0.333333E+09 | 44629581.76 | 0.00 | 0.28 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 | 3258.75 | 30-MAR-16:10 | 3090.18 | 30-MAR-16:07 | 570.46 | 30-MAR-11:40 | 863.20 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.195983E+10 | 0.502235E+09 | 376.81 | 0.175837E+10 | 0.201455E+09 | 0.00 | 0.28 | 17-APR-16:08 | 0.00 | 01-APR-00:10 | 3281.05 | 04-APR-16:15 | 3155.69 | 17-APR-16:08 | 866.05 | 04-APR-15:10 | 857.73 | 17-APR-16:08 | 0.00 | 01-APR-00:10 |
| May | 0.485423E+10 | 0.123165E+10 | 640.96 | 0.403884E+10 | 0.815393E+09 | 0.00 | 0.39 | 30-MAY-15:10 | 0.00 | 01-MAY-01:10 | 4746.70 | 30-MAY-15:10 | 4009.13 | 30-MAY-15:10 | 1219.86 | 31-MAY-09:40 | 1268.66 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.849286E+10 | 0.217954E+10 | 705.81 | 0.665773E+10 | 0.183514E+10 | 0.00 | 0.52 | 06-JUN-17:00 | 0.00 | 02-JUN-05:40 | 6338.45 | 28-JUN-15:00 | 5258.10 | 06-JUN-17:05 | 1841.17 | 29-JUN-09:30 | 1718.49 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.101803E+11 | 0.260731E+10 | 742.06 | 0.752453E+10 | 0.265573E+10 | 0.00 | 0.52 | 15-JUL-16:50 | 0.00 | 29-JUL-05:05 | 6438.96 | 22-JUL-11:00 | 5208.99 | 08-JUL-16:03 | 1836.73 | 31-JUL-09:30 | 1783.26 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.107143E+11 | 0.271593E+10 | 744.00 | 0.766036E+10 | 0.305397E+10 | 0.00 | 0.55 | 01-AUG-17:00 | 0.03 | 25-AUG-06:00 | 6572.80 | 01-AUG-17:00 | 5402.92 | 01-AUG-17:00 | 2059.33 | 20-AUG-16:10 | 1852.12 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.577933E+10 | 0.145065E+10 | 649.90 | 0.436927E+10 | 0.141006E+10 | 0.00 | 0.45 | 06-SEP-12:40 | 0.00 | 14-SEP-01:30 | 5606.11 | 06-SEP-12:30 | 4268.03 | 07-SEP-16:03 | 1507.76 | 06-SEP-12:30 | 1482.82 | 06-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.146635E+10 | 0.364674E+09 | 267.17 | 0.109799E+10 | 0.368363E+09 | 0.00 | 0.32 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 4128.67 | 18-OCT-16:05 | 3135.98 | 10-OCT-16:08 | 1574.29 | 18-OCT-13:10 | 1014.60 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 50261220.95 | 12503352.92 | 19.92 | 37646020.90 | 12615200.06 | 0.00 | 0.17 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 2001.25 | 05-NOV-16:10 | 1604.87 | 05-NOV-16:10 | 428.46 | 05-NOV-15:10 | 498.92 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.439001E+11 | 0.111680E+11 | 4255.79 | 0.335027E+11 | 0.103974E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.107143E+11 | 0.271593E+10 | 744.00 | 0.766036E+10 | 0.305397E+10 | 0.00 | 0.55 | 0.03 | 6572.80 | 5402.92 | 2059.33 | 1852.12 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 21584715.71 | 5710502.74 | 13.00 | 21584715.71 | -0.0 | 0.00 | 0.10 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 | 969.98 | 28-FEB-17:10 | 969.98 | 28-FEB-17:10 | 0.00 | 28-FEB-15:10 | 254.45 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.384179E+09 | 98618151.39 | 116.47 | 0.339149E+09 | 45029435.98 | 0.00 | 0.26 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 | 2752.79 | 30-MAR-16:10 | 2595.24 | 30-MAR-16:10 | 460.44 | 30-MAR-11:50 | 730.52 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.181443E+10 | 0.463907E+09 | 433.80 | 0.159973E+10 | 0.214693E+09 | 0.00 | 0.27 | 04-APR-16:15 | 0.00 | 01-APR-00:10 | 2977.90 | 04-APR-16:15 | 2581.44 | 17-APR-16:17 | 766.10 | 04-APR-13:40 | 744.51 | 04-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.419383E+10 | 0.106453E+10 | 672.89 | 0.344332E+10 | 0.750511E+09 | 0.00 | 0.36 | 30-MAY-18:00 | 0.00 | 01-MAY-05:05 | 3944.49 | 30-MAY-18:00 | 3224.20 | 19-MAY-17:40 | 1044.66 | 07-MAY-17:00 | 1011.06 | 30-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.703058E+10 | 0.180719E+10 | 715.06 | 0.545621E+10 | 0.157437E+10 | 0.00 | 0.46 | 06-JUN-17:05 | 0.00 | 02-JUN-05:40 | 4977.62 | 23-JUN-17:00 | 4126.69 | 06-JUN-17:03 | 1393.30 | 29-JUN-10:00 | 1361.58 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.845669E+10 | 0.216840E+10 | 744.00 | 0.615343E+10 | 0.230327E+10 | 0.00 | 0.48 | 15-JUL-17:05 | 0.03 | 29-JUL-05:05 | 5281.03 | 15-JUL-17:05 | 4125.85 | 08-JUL-16:01 | 1493.22 | 01-JUL-18:30 | 1452.68 | 15-JUL-17:05 | 0.00 | 01-JUL-00:10 |
| August | 0.895415E+10 | 0.227130E+10 | 744.00 | 0.631625E+10 | 0.263789E+10 | 0.00 | 0.49 | 01-AUG-17:00 | 0.06 | 25-AUG-06:00 | 5183.89 | 01-AUG-17:00 | 4212.66 | 01-AUG-17:00 | 1693.98 | 20-AUG-16:10 | 1473.85 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.510051E+10 | 0.127929E+10 | 673.51 | 0.381868E+10 | 0.128184E+10 | 0.00 | 0.41 | 07-SEP-16:10 | 0.00 | 14-SEP-03:50 | 4420.93 | 07-SEP-16:10 | 3392.21 | 07-SEP-16:03 | 1280.04 | 16-SEP-18:00 | 1194.72 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.142469E+10 | 0.354323E+09 | 308.31 | 0.107050E+10 | 0.354196E+09 | 0.00 | 0.32 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 3649.03 | 18-OCT-16:05 | 2639.79 | 10-OCT-16:10 | 1441.26 | 18-OCT-21:00 | 882.12 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 84550667.11 | 21034072.55 | 42.56 | 63223212.58 | 21327454.54 | 0.00 | 0.19 | 05-NOV-16:05 | 0.00 | 01-NOV-00:10 | 2073.39 | 05-NOV-16:05 | 1674.15 | 05-NOV-16:05 | 431.11 | 05-NOV-15:10 | 515.45 | 05-NOV-16:05 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.374652E+11 | 0.953430E+10 | 4463.60 | 0.282821E+11 | 0.918313E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.895415E+10 | 0.227130E+10 | 744.00 | 0.631625E+10 | 0.263789E+10 | 0.00 | 0.49 | 0.06 | 5281.03 | 4212.66 | 1693.98 | 1473.85 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 22272302.98 | 5891894.32 | 13.17 | 22272302.98 | 0.00 | 0.00 | 0.10 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 | 978.62 | 28-FEB-17:10 | 978.62 | 28-FEB-17:10 | 0.00 | 28-FEB-18:00 | 256.68 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.383631E+09 | 98473480.57 | 116.31 | 0.338533E+09 | 45098122.90 | 0.00 | 0.26 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 | 2743.37 | 30-MAR-16:10 | 2586.15 | 30-MAR-16:10 | 461.92 | 30-MAR-11:50 | 728.09 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.181688E+10 | 0.464549E+09 | 433.91 | 0.160224E+10 | 0.214641E+09 | 0.00 | 0.27 | 04-APR-16:15 | 0.00 | 01-APR-00:10 | 2973.79 | 04-APR-16:15 | 2580.55 | 17-APR-16:17 | 765.42 | 04-APR-13:40 | 743.47 | 04-APR-16:15 | 0.00 | 01-APR-00:10 |
| May | 0.419932E+10 | 0.106589E+10 | 673.42 | 0.344829E+10 | 0.751030E+09 | 0.00 | 0.36 | 30-MAY-18:00 | 0.00 | 01-MAY-05:05 | 3943.93 | 30-MAY-18:00 | 3213.42 | 19-MAY-17:40 | 1046.70 | 07-MAY-17:00 | 1010.87 | 30-MAY-18:00 | 0.00 | 01-MAY-00:10 |
| June | 0.703591E+10 | 0.180847E+10 | 715.06 | 0.546080E+10 | 0.157511E+10 | 0.00 | 0.46 | 06-JUN-17:05 | 0.00 | 02-JUN-05:40 | 4967.20 | 23-JUN-17:00 | 4120.49 | 06-JUN-17:05 | 1397.52 | 29-JUN-10:00 | 1359.86 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.846292E+10 | 0.216985E+10 | 744.00 | 0.615841E+10 | 0.230452E+10 | 0.00 | 0.48 | 15-JUL-17:08 | 0.03 | 29-JUL-05:05 | 5269.51 | 15-JUL-17:05 | 4124.53 | 08-JUL-16:01 | 1495.84 | 01-JUL-18:30 | 1449.60 | 15-JUL-17:05 | 0.00 | 01-JUL-00:10 |
| August | 0.895547E+10 | 0.227157E+10 | 744.00 | 0.631728E+10 | 0.263819E+10 | 0.00 | 0.49 | 01-AUG-17:00 | 0.06 | 25-AUG-06:00 | 5178.02 | 01-AUG-17:00 | 4208.00 | 01-AUG-17:00 | 1690.89 | 20-AUG-16:10 | 1472.19 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.510286E+10 | 0.127985E+10 | 673.51 | 0.382059E+10 | 0.128227E+10 | 0.00 | 0.41 | 07-SEP-16:10 | 0.00 | 14-SEP-03:50 | 4418.19 | 07-SEP-16:10 | 3390.60 | 07-SEP-16:03 | 1279.57 | 16-SEP-18:00 | 1193.97 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.143149E+10 | 0.356045E+09 | 310.07 | 0.107660E+10 | 0.354896E+09 | 0.00 | 0.32 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 | 3650.77 | 18-OCT-16:05 | 2635.97 | 10-OCT-16:10 | 1441.93 | 18-OCT-21:00 | 882.49 | 18-OCT-16:05 | 0.00 | 01-OCT-00:10 |
| November | 83806252.72 | 20848655.12 | 41.89 | 62651796.46 | 21154456.27 | 0.00 | 0.19 | 05-NOV-16:05 | 0.00 | 01-NOV-00:10 | 2062.49 | 05-NOV-16:05 | 1664.79 | 05-NOV-16:05 | 429.84 | 05-NOV-15:10 | 512.79 | 05-NOV-16:05 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.374946E+11 | 0.954144E+10 | 4465.33 | 0.283077E+11 | 0.918691E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.895547E+10 | 0.227157E+10 | 744.00 | 0.631728E+10 | 0.263819E+10 | 0.00 | 0.49 | 0.06 | 5269.51 | 4208.00 | 1690.89 | 1472.19 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.318943E+09 | 83201897.13 | 86.58 | 0.318695E+09 | 248458.05 | 0.00 | 0.27 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 | 2800.31 | 26-FEB-15:00 | 2800.31 | 26-FEB-15:00 | 29.54 | 22-FEB-21:00 | 728.03 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.107894E+10 | 0.276964E+09 | 270.42 | 0.100077E+10 | 78168021.31 | 0.00 | 0.34 | 30-MAR-14:10 | 0.00 | 01-MAR-01:30 | 3698.27 | 30-MAR-14:10 | 3511.34 | 30-MAR-16:07 | 601.03 | 30-MAR-11:40 | 968.96 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
| April | 0.251621E+10 | 0.643118E+09 | 495.25 | 0.227443E+10 | 0.241783E+09 | 0.00 | 0.33 | 15-APR-16:07 | 0.00 | 01-APR-00:10 | 3436.61 | 15-APR-16:07 | 3436.61 | 15-APR-16:07 | 893.02 | 04-APR-13:30 | 919.04 | 15-APR-16:07 | 0.00 | 01-APR-00:10 |
| May | 0.455271E+10 | 0.115553E+10 | 682.03 | 0.377531E+10 | 0.777404E+09 | 0.00 | 0.37 | 29-MAY-16:15 | 0.00 | 01-MAY-05:05 | 3997.59 | 29-MAY-16:15 | 3529.46 | 19-MAY-16:03 | 1123.79 | 07-MAY-17:00 | 1072.76 | 29-MAY-16:15 | 0.00 | 01-MAY-00:10 |
| June | 0.708338E+10 | 0.182352E+10 | 713.27 | 0.551556E+10 | 0.156782E+10 | 0.00 | 0.46 | 25-JUN-16:02 | 0.00 | 02-JUN-05:40 | 5133.56 | 25-JUN-16:02 | 4166.98 | 06-JUN-17:08 | 1379.65 | 23-JUN-12:00 | 1420.36 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.860999E+10 | 0.221033E+10 | 744.00 | 0.629116E+10 | 0.231884E+10 | 0.00 | 0.50 | 08-JUL-16:03 | 0.03 | 29-JUL-05:05 | 5487.59 | 15-JUL-16:30 | 4440.86 | 08-JUL-16:03 | 1518.18 | 01-JUL-18:30 | 1551.20 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.955954E+10 | 0.242640E+10 | 744.00 | 0.685437E+10 | 0.270517E+10 | 0.00 | 0.51 | 19-AUG-16:10 | 0.07 | 25-AUG-06:00 | 5694.21 | 19-AUG-16:10 | 4478.46 | 18-AUG-16:03 | 1803.88 | 20-AUG-16:10 | 1538.52 | 19-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.617924E+10 | 0.154798E+10 | 687.54 | 0.478452E+10 | 0.139472E+10 | 0.00 | 0.47 | 07-SEP-16:10 | 0.00 | 14-SEP-08:20 | 5325.69 | 06-SEP-13:00 | 4311.65 | 23-SEP-15:20 | 1428.11 | 16-SEP-13:30 | 1412.39 | 07-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.279731E+10 | 0.699273E+09 | 452.54 | 0.234524E+10 | 0.452070E+09 | 0.00 | 0.45 | 10-OCT-14:10 | 0.00 | 01-OCT-05:05 | 5100.24 | 11-OCT-14:10 | 4356.74 | 10-OCT-16:03 | 1476.30 | 18-OCT-21:00 | 1325.24 | 10-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.764581E+09 | 0.195332E+09 | 232.39 | 0.687208E+09 | 77372390.65 | 0.00 | 0.32 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 3592.47 | 05-NOV-16:10 | 3067.22 | 05-NOV-16:10 | 742.32 | 05-NOV-13:30 | 882.32 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.114502E+09 | 29138224.06 | 51.95 | 99567440.42 | 14934808.80 | 0.00 | 0.22 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2436.50 | 12-DEC-14:00 | 2044.33 | 12-DEC-14:00 | 392.17 | 12-DEC-14:00 | 604.75 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.435754E+11 | 0.110908E+11 | 5159.97 | 0.339468E+11 | 0.962853E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.955954E+10 | 0.242640E+10 | 744.00 | 0.685437E+10 | 0.270517E+10 | 0.00 | 0.51 | 0.07 | 5694.21 | 4478.46 | 1803.88 | 1551.20 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.323381E+09 | 84349130.00 | 87.97 | 0.323115E+09 | 266281.79 | 0.00 | 0.27 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 | 2829.84 | 26-FEB-15:00 | 2829.84 | 26-FEB-15:00 | 30.91 | 22-FEB-21:00 | 735.37 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.108157E+10 | 0.277636E+09 | 270.25 | 0.100322E+10 | 78347638.56 | 0.00 | 0.34 | 30-MAR-14:10 | 0.00 | 01-MAR-01:30 | 3699.60 | 30-MAR-14:10 | 3501.63 | 30-MAR-16:07 | 602.46 | 30-MAR-11:40 | 969.25 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
| April | 0.251936E+10 | 0.643910E+09 | 494.67 | 0.227760E+10 | 0.241762E+09 | 0.00 | 0.33 | 15-APR-16:07 | 0.00 | 01-APR-00:10 | 3431.51 | 15-APR-16:07 | 3431.51 | 15-APR-16:07 | 892.90 | 04-APR-13:30 | 917.70 | 15-APR-16:07 | 0.00 | 01-APR-00:10 |
| May | 0.455815E+10 | 0.115686E+10 | 681.85 | 0.378024E+10 | 0.777912E+09 | 0.00 | 0.37 | 29-MAY-16:15 | 0.00 | 01-MAY-05:05 | 3995.13 | 30-MAY-18:00 | 3527.44 | 19-MAY-16:03 | 1125.71 | 07-MAY-17:00 | 1071.43 | 29-MAY-16:15 | 0.00 | 01-MAY-00:10 |
| June | 0.708889E+10 | 0.182485E+10 | 713.31 | 0.552033E+10 | 0.156856E+10 | 0.00 | 0.46 | 25-JUN-16:02 | 0.00 | 02-JUN-05:40 | 5127.63 | 25-JUN-16:02 | 4160.80 | 06-JUN-17:08 | 1380.88 | 23-JUN-12:00 | 1418.73 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.861625E+10 | 0.221179E+10 | 744.00 | 0.629618E+10 | 0.232008E+10 | 0.00 | 0.50 | 08-JUL-16:03 | 0.03 | 29-JUL-05:05 | 5479.65 | 15-JUL-16:30 | 4439.45 | 08-JUL-16:03 | 1520.76 | 01-JUL-18:30 | 1550.49 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.956084E+10 | 0.242664E+10 | 744.00 | 0.685539E+10 | 0.270545E+10 | 0.00 | 0.51 | 19-AUG-16:10 | 0.07 | 25-AUG-06:00 | 5691.54 | 19-AUG-16:10 | 4474.56 | 18-AUG-16:03 | 1801.13 | 20-AUG-16:10 | 1540.12 | 19-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.618122E+10 | 0.154841E+10 | 687.44 | 0.478615E+10 | 0.139507E+10 | 0.00 | 0.47 | 06-SEP-13:00 | 0.00 | 14-SEP-08:20 | 5338.10 | 06-SEP-13:00 | 4313.73 | 23-SEP-15:20 | 1427.92 | 16-SEP-13:30 | 1415.01 | 06-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.280171E+10 | 0.700350E+09 | 452.74 | 0.234942E+10 | 0.452284E+09 | 0.00 | 0.46 | 10-OCT-14:10 | 0.00 | 01-OCT-05:05 | 5106.26 | 11-OCT-14:10 | 4360.12 | 10-OCT-14:10 | 1476.67 | 18-OCT-21:00 | 1326.68 | 10-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.765652E+09 | 0.195616E+09 | 232.97 | 0.688428E+09 | 77223906.55 | 0.00 | 0.32 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 3582.04 | 05-NOV-16:10 | 3057.69 | 05-NOV-16:10 | 742.38 | 05-NOV-13:30 | 879.82 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 0.114982E+09 | 29262933.92 | 52.51 | 0.100016E+09 | 14965607.60 | 0.00 | 0.22 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2437.93 | 12-DEC-14:00 | 2045.51 | 12-DEC-14:00 | 392.42 | 12-DEC-14:00 | 605.07 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.436120E+11 | 0.110997E+11 | 5161.72 | 0.339801E+11 | 0.963192E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.956084E+10 | 0.242664E+10 | 744.00 | 0.685539E+10 | 0.270545E+10 | 0.00 | 0.51 | 0.07 | 5691.54 | 4474.56 | 1801.13 | 1550.49 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 3356976.86 | 897838.98 | 5.83 | 3356976.86 | -0.0 | 0.00 | 0.06 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 | 427.64 | 29-JAN-15:00 | 427.64 | 29-JAN-15:00 | 0.00 | 29-JAN-17:20 | 113.80 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.162884E+09 | 42367617.40 | 47.67 | 0.162884E+09 | 0.00 | 0.00 | 0.33 | 26-FEB-16:30 | 0.00 | 01-FEB-00:10 | 2369.69 | 26-FEB-16:30 | 2369.69 | 26-FEB-16:30 | 0.00 | 26-FEB-16:20 | 603.59 | 26-FEB-16:20 | 0.00 | 01-FEB-00:10 |
| March | 0.540802E+09 | 0.138830E+09 | 162.78 | 0.506097E+09 | 34705155.13 | 0.00 | 0.44 | 30-MAR-16:20 | 0.00 | 01-MAR-00:10 | 3272.20 | 30-MAR-16:20 | 3152.86 | 30-MAR-16:07 | 392.28 | 30-MAR-11:50 | 845.16 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.131696E+10 | 0.337450E+09 | 295.17 | 0.122297E+10 | 93982594.03 | 0.00 | 0.43 | 17-APR-16:10 | 0.00 | 01-APR-00:10 | 3094.66 | 17-APR-16:10 | 3094.66 | 17-APR-16:10 | 546.85 | 04-APR-13:40 | 821.78 | 17-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.261110E+10 | 0.665374E+09 | 480.67 | 0.222735E+10 | 0.383744E+09 | 0.00 | 0.50 | 19-MAY-16:10 | 0.00 | 01-MAY-00:10 | 3664.19 | 06-MAY-16:03 | 3461.12 | 19-MAY-16:05 | 728.91 | 07-MAY-17:00 | 978.97 | 19-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.460865E+10 | 0.119329E+10 | 655.71 | 0.366280E+10 | 0.945852E+09 | 0.00 | 0.61 | 25-JUN-16:02 | 0.00 | 01-JUN-04:50 | 4633.77 | 25-JUN-16:02 | 4009.48 | 06-JUN-17:10 | 1026.72 | 23-JUN-12:00 | 1257.29 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.560591E+10 | 0.145139E+10 | 719.67 | 0.423419E+10 | 0.137172E+10 | 0.00 | 0.65 | 08-JUL-16:01 | 0.00 | 02-JUL-05:05 | 4897.19 | 15-JUL-16:40 | 4178.47 | 08-JUL-16:10 | 1071.14 | 23-JUL-16:15 | 1359.97 | 08-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 0.623116E+10 | 0.159208E+10 | 741.33 | 0.458211E+10 | 0.164905E+10 | 0.00 | 0.67 | 01-AUG-17:00 | 0.00 | 25-AUG-05:05 | 5035.35 | 01-AUG-17:10 | 4320.26 | 01-AUG-17:00 | 1393.26 | 20-AUG-16:10 | 1394.40 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.336801E+10 | 0.848863E+09 | 578.31 | 0.264190E+10 | 0.726107E+09 | 0.00 | 0.60 | 07-SEP-16:10 | 0.00 | 01-SEP-08:00 | 4586.80 | 07-SEP-16:10 | 3804.37 | 07-SEP-16:08 | 1038.81 | 16-SEP-13:30 | 1211.32 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.123635E+10 | 0.309203E+09 | 261.63 | 0.103012E+10 | 0.206221E+09 | 0.00 | 0.52 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 | 3926.20 | 10-OCT-16:02 | 3502.99 | 10-OCT-16:03 | 952.17 | 18-OCT-13:10 | 1029.12 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 0.262808E+09 | 67283323.59 | 102.25 | 0.241762E+09 | 21045924.88 | 0.00 | 0.33 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 2516.82 | 05-NOV-16:10 | 2185.19 | 05-NOV-16:10 | 469.15 | 05-NOV-13:40 | 618.47 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 41496254.77 | 10709813.78 | 24.39 | 38181586.05 | 3314668.72 | 0.00 | 0.17 | 12-DEC-14:30 | 0.00 | 01-DEC-00:10 | 1280.68 | 12-DEC-14:30 | 1074.63 | 12-DEC-14:30 | 216.58 | 12-DEC-14:00 | 320.25 | 12-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.259895E+11 | 0.665774E+10 | 4075.39 | 0.205537E+11 | 0.543574E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 3356976.86 | 897838.98 | 5.83 | 3356976.86 | -0.0 | 0.00 | 0.06 | 0.00 | 427.64 | 427.64 | 0.00 | 113.80 | 0.00 | |||||||
| Maximum of Months | 0.623116E+10 | 0.159208E+10 | 741.33 | 0.458211E+10 | 0.164905E+10 | 0.00 | 0.67 | 0.00 | 5035.35 | 4320.26 | 1393.26 | 1394.40 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 36112122.71 | 9530636.75 | 21.00 | 36112122.71 | 0.00 | 0.00 | 0.13 | 26-FEB-17:10 | 0.00 | 01-FEB-00:10 | 917.15 | 26-FEB-17:10 | 917.15 | 26-FEB-17:10 | 0.00 | 26-FEB-17:40 | 240.01 | 26-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.260289E+09 | 66765009.80 | 91.83 | 0.234141E+09 | 26148111.96 | 0.00 | 0.37 | 30-MAR-16:30 | 0.00 | 01-MAR-00:10 | 2718.77 | 30-MAR-16:40 | 2582.42 | 30-MAR-16:30 | 302.91 | 30-MAR-12:00 | 704.65 | 30-MAR-16:30 | 0.00 | 01-MAR-00:10 |
| April | 0.100027E+10 | 0.257299E+09 | 262.00 | 0.916334E+09 | 83930921.58 | 0.00 | 0.37 | 17-APR-16:50 | 0.00 | 01-APR-00:10 | 2589.96 | 17-APR-17:05 | 2589.96 | 17-APR-17:05 | 494.21 | 04-APR-15:10 | 689.99 | 17-APR-16:40 | 0.00 | 01-APR-00:10 |
| May | 0.242172E+10 | 0.617872E+09 | 474.00 | 0.204955E+10 | 0.372171E+09 | 0.00 | 0.48 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 | 3509.66 | 19-MAY-17:30 | 3285.37 | 19-MAY-17:30 | 684.13 | 07-MAY-17:00 | 933.45 | 19-MAY-17:30 | 0.00 | 01-MAY-00:10 |
| June | 0.457093E+10 | 0.118278E+10 | 657.69 | 0.361995E+10 | 0.950982E+09 | 0.00 | 0.62 | 06-JUN-17:00 | 0.00 | 01-JUN-04:50 | 4545.92 | 06-JUN-17:03 | 3972.54 | 06-JUN-17:05 | 1018.60 | 26-JUN-15:10 | 1251.00 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.552535E+10 | 0.143021E+10 | 719.42 | 0.415767E+10 | 0.136768E+10 | 0.00 | 0.63 | 15-JUL-16:40 | 0.00 | 02-JUL-05:05 | 4757.99 | 15-JUL-16:40 | 3938.37 | 08-JUL-16:20 | 1046.74 | 31-JUL-15:20 | 1286.04 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.590526E+10 | 0.150999E+10 | 741.33 | 0.428547E+10 | 0.161979E+10 | 0.00 | 0.66 | 01-AUG-17:00 | 0.00 | 25-AUG-05:05 | 4900.71 | 01-AUG-17:00 | 4163.53 | 01-AUG-17:00 | 1334.75 | 20-AUG-16:10 | 1359.83 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.280897E+10 | 0.710193E+09 | 560.78 | 0.213605E+10 | 0.672927E+09 | 0.00 | 0.54 | 07-SEP-16:13 | 0.00 | 01-SEP-07:50 | 4054.10 | 07-SEP-16:13 | 3269.69 | 07-SEP-16:17 | 946.99 | 16-SEP-13:30 | 1075.90 | 07-SEP-16:08 | 0.00 | 01-SEP-00:10 |
| October | 0.675769E+09 | 0.168738E+09 | 189.00 | 0.510403E+09 | 0.165366E+09 | 0.00 | 0.38 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 | 2791.44 | 10-OCT-16:13 | 2376.98 | 10-OCT-16:17 | 940.59 | 18-OCT-13:10 | 744.30 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 36800405.34 | 9221320.35 | 26.75 | 28795982.90 | 8004422.44 | 0.00 | 0.20 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1457.85 | 05-NOV-16:10 | 1190.21 | 05-NOV-16:10 | 292.85 | 05-NOV-15:10 | 362.73 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 583066.32 | 149840.17 | 2.17 | 500124.63 | 82941.68 | 0.00 | 0.02 | 12-DEC-17:10 | 0.00 | 01-DEC-00:10 | 143.59 | 12-DEC-17:10 | 123.25 | 12-DEC-17:10 | 20.34 | 12-DEC-17:10 | 36.86 | 12-DEC-17:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.232421E+11 | 0.596274E+10 | 3745.98 | 0.179750E+11 | 0.526708E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.590526E+10 | 0.150999E+10 | 741.33 | 0.428547E+10 | 0.161979E+10 | 0.00 | 0.66 | 0.00 | 4900.71 | 4163.53 | 1334.75 | 1359.83 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 2697997.17 | 719246.01 | 3.68 | 2697997.17 | -0.0 | 0.00 | 0.07 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 | 455.38 | 29-JAN-15:00 | 455.38 | 29-JAN-15:00 | 0.00 | 29-JAN-14:30 | 120.96 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.156615E+09 | 40726531.50 | 49.25 | 0.156615E+09 | 0.00 | 0.00 | 0.32 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 | 2053.15 | 26-FEB-15:00 | 2053.15 | 26-FEB-15:00 | 0.00 | 26-FEB-14:10 | 529.68 | 26-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.466344E+09 | 0.119570E+09 | 157.47 | 0.432992E+09 | 33352174.96 | 0.00 | 0.43 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 | 2902.42 | 30-MAR-14:10 | 2707.76 | 30-MAR-15:10 | 439.21 | 30-MAR-11:40 | 750.78 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
| April | 0.127696E+10 | 0.326793E+09 | 294.75 | 0.118456E+10 | 92400671.06 | 0.00 | 0.43 | 16-APR-14:00 | 0.00 | 01-APR-00:10 | 2770.10 | 16-APR-14:00 | 2770.10 | 16-APR-14:00 | 545.48 | 04-APR-13:40 | 737.41 | 16-APR-14:00 | 0.00 | 01-APR-00:10 |
| May | 0.263575E+10 | 0.668853E+09 | 488.64 | 0.224344E+10 | 0.392314E+09 | 0.00 | 0.50 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 3385.49 | 30-MAY-15:10 | 2950.62 | 30-MAY-14:30 | 737.20 | 31-MAY-09:50 | 895.60 | 30-MAY-14:40 | 0.00 | 01-MAY-00:10 |
| June | 0.466981E+10 | 0.120190E+10 | 659.85 | 0.371145E+10 | 0.958352E+09 | 0.00 | 0.62 | 06-JUN-14:10 | 0.00 | 01-JUN-04:50 | 4205.11 | 06-JUN-14:10 | 3594.55 | 06-JUN-14:10 | 1104.14 | 29-JUN-10:00 | 1156.58 | 06-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.568458E+10 | 0.146125E+10 | 718.92 | 0.428993E+10 | 0.139465E+10 | 0.00 | 0.66 | 08-JUL-13:00 | 0.00 | 02-JUL-05:05 | 4455.36 | 08-JUL-13:00 | 3760.71 | 08-JUL-16:03 | 1137.87 | 26-JUL-10:40 | 1248.76 | 08-JUL-13:20 | 0.00 | 01-JUL-00:10 |
| August | 0.623513E+10 | 0.158371E+10 | 741.50 | 0.458067E+10 | 0.165445E+10 | 0.00 | 0.67 | 19-AUG-14:00 | 0.00 | 25-AUG-05:05 | 4650.93 | 19-AUG-14:00 | 3865.63 | 19-AUG-14:00 | 1303.24 | 20-AUG-16:10 | 1261.93 | 19-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.338209E+10 | 0.848447E+09 | 581.61 | 0.265034E+10 | 0.731749E+09 | 0.00 | 0.63 | 06-SEP-13:00 | 0.00 | 02-SEP-05:05 | 4496.14 | 06-SEP-13:00 | 3502.46 | 06-SEP-13:10 | 1018.10 | 16-SEP-13:30 | 1164.68 | 06-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.120232E+10 | 0.299715E+09 | 266.42 | 0.994445E+09 | 0.207879E+09 | 0.00 | 0.53 | 10-OCT-14:00 | 0.00 | 01-OCT-00:10 | 3686.75 | 11-OCT-14:10 | 3174.05 | 10-OCT-14:10 | 959.24 | 18-OCT-13:10 | 946.32 | 10-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.224805E+09 | 57558652.74 | 99.35 | 0.205901E+09 | 18904798.10 | 0.00 | 0.31 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 | 2117.90 | 05-NOV-15:30 | 1784.66 | 05-NOV-16:10 | 446.20 | 05-NOV-13:30 | 520.93 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 |
| December | 32448358.60 | 8337413.56 | 20.67 | 29361156.80 | 3087201.79 | 0.00 | 0.18 | 12-DEC-14:10 | 0.00 | 01-DEC-00:10 | 1218.77 | 12-DEC-14:10 | 1013.92 | 12-DEC-14:20 | 212.61 | 12-DEC-14:00 | 303.84 | 12-DEC-14:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.259695E+11 | 0.661759E+10 | 4082.10 | 0.204824E+11 | 0.548714E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 2697997.17 | 719246.01 | 3.68 | 2697997.17 | -0.0 | 0.00 | 0.07 | 0.00 | 455.38 | 455.38 | 0.00 | 120.96 | 0.00 | |||||||
| Maximum of Months | 0.623513E+10 | 0.158371E+10 | 741.50 | 0.458067E+10 | 0.165445E+10 | 0.00 | 0.67 | 0.00 | 4650.93 | 3865.63 | 1303.24 | 1261.93 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 26997427.15 | 7148732.05 | 21.50 | 26997427.15 | -0.0 | 0.00 | 0.11 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 | 697.37 | 28-FEB-15:00 | 697.37 | 28-FEB-15:00 | 0.00 | 28-FEB-14:50 | 185.20 | 28-FEB-15:00 | 0.00 | 01-FEB-00:10 |
| March | 0.218629E+09 | 56051194.13 | 84.50 | 0.193829E+09 | 24800248.14 | 0.00 | 0.33 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 | 2160.37 | 30-MAR-16:10 | 2059.24 | 30-MAR-16:10 | 351.97 | 30-MAR-11:50 | 567.98 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.954998E+09 | 0.245614E+09 | 269.67 | 0.872422E+09 | 82575921.25 | 0.00 | 0.32 | 19-APR-15:10 | 0.00 | 01-APR-00:10 | 2093.83 | 19-APR-15:10 | 2010.09 | 17-APR-16:05 | 489.70 | 04-APR-15:10 | 543.08 | 17-APR-16:05 | 0.00 | 01-APR-00:10 |
| May | 0.244720E+10 | 0.621952E+09 | 483.90 | 0.206575E+10 | 0.381454E+09 | 0.00 | 0.48 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 3204.20 | 30-MAY-15:10 | 2756.27 | 30-MAY-15:10 | 741.39 | 31-MAY-09:50 | 847.03 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.463316E+10 | 0.119170E+10 | 661.46 | 0.367012E+10 | 0.963039E+09 | 0.00 | 0.60 | 06-JUN-16:40 | 0.00 | 01-JUN-04:50 | 4076.16 | 28-JUN-15:00 | 3435.74 | 06-JUN-17:00 | 1116.10 | 29-JUN-09:50 | 1103.00 | 06-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.560395E+10 | 0.144018E+10 | 718.42 | 0.421391E+10 | 0.139004E+10 | 0.00 | 0.62 | 07-JUL-13:00 | 0.00 | 02-JUL-05:05 | 4262.42 | 07-JUL-13:00 | 3516.37 | 08-JUL-16:03 | 1126.44 | 31-JUL-09:30 | 1162.14 | 08-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.591023E+10 | 0.150279E+10 | 741.33 | 0.428464E+10 | 0.162558E+10 | 0.00 | 0.64 | 01-AUG-17:00 | 0.00 | 25-AUG-05:00 | 4316.68 | 01-AUG-17:00 | 3625.02 | 01-AUG-17:00 | 1235.90 | 20-AUG-16:10 | 1199.94 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.282185E+10 | 0.710825E+09 | 566.34 | 0.214183E+10 | 0.680014E+09 | 0.00 | 0.53 | 06-SEP-13:00 | 0.00 | 02-SEP-05:05 | 3716.36 | 06-SEP-13:00 | 2817.07 | 07-SEP-16:10 | 940.82 | 06-SEP-12:30 | 974.66 | 06-SEP-13:00 | 0.00 | 01-SEP-00:10 |
| October | 0.637505E+09 | 0.158458E+09 | 186.17 | 0.471152E+09 | 0.166353E+09 | 0.00 | 0.34 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 | 2423.66 | 18-OCT-16:05 | 1920.01 | 10-OCT-16:03 | 949.10 | 18-OCT-13:10 | 612.09 | 10-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 25775506.06 | 6452804.56 | 20.08 | 19843082.47 | 5932423.59 | 0.00 | 0.16 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1041.53 | 05-NOV-16:10 | 831.50 | 05-NOV-16:10 | 229.39 | 05-NOV-15:10 | 259.90 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 156662.71 | 40290.90 | 1.17 | 134539.16 | 22123.55 | 0.00 | 0.01 | 12-DEC-17:10 | 0.00 | 01-DEC-00:10 | 82.24 | 12-DEC-17:10 | 70.49 | 12-DEC-17:10 | 11.75 | 12-DEC-17:10 | 21.13 | 12-DEC-17:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.232804E+11 | 0.594120E+10 | 3754.53 | 0.179606E+11 | 0.531982E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.591023E+10 | 0.150279E+10 | 741.33 | 0.428464E+10 | 0.162558E+10 | 0.00 | 0.64 | 0.00 | 4316.68 | 3625.02 | 1235.90 | 1199.94 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 16954918.06 | 4494924.17 | 16.83 | 16954918.06 | 0.00 | 0.00 | 0.10 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 | 543.83 | 28-FEB-17:10 | 543.83 | 28-FEB-17:10 | 0.00 | 26-FEB-17:20 | 142.69 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.187606E+09 | 48102236.19 | 84.50 | 0.165511E+09 | 22095494.07 | 0.00 | 0.31 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 | 1830.17 | 30-MAR-16:10 | 1740.13 | 30-MAR-16:07 | 277.27 | 30-MAR-12:00 | 482.72 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.789579E+09 | 0.202986E+09 | 283.67 | 0.710022E+09 | 79557066.14 | 0.00 | 0.29 | 19-APR-15:10 | 0.00 | 01-APR-00:10 | 1761.71 | 19-APR-15:10 | 1678.25 | 17-APR-16:20 | 406.36 | 04-APR-14:10 | 457.02 | 19-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.203211E+10 | 0.517801E+09 | 514.68 | 0.169465E+10 | 0.337458E+09 | 0.00 | 0.42 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2567.59 | 30-MAY-15:10 | 2195.29 | 30-MAY-15:10 | 600.93 | 07-MAY-17:00 | 684.22 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.383947E+10 | 0.991579E+09 | 667.94 | 0.301686E+10 | 0.822604E+09 | 0.00 | 0.53 | 06-JUN-17:00 | 0.00 | 01-JUN-05:05 | 3239.54 | 23-JUN-17:00 | 2774.94 | 06-JUN-17:05 | 835.93 | 29-JUN-10:00 | 892.20 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.467510E+10 | 0.120626E+10 | 727.97 | 0.347710E+10 | 0.119800E+10 | 0.00 | 0.57 | 08-JUL-16:03 | 0.00 | 03-JUL-05:05 | 3471.91 | 15-JUL-16:50 | 2897.45 | 08-JUL-16:03 | 880.81 | 26-JUL-11:00 | 970.80 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.496511E+10 | 0.126658E+10 | 741.71 | 0.356947E+10 | 0.139564E+10 | 0.00 | 0.58 | 01-AUG-17:00 | 0.00 | 25-AUG-05:05 | 3494.18 | 01-AUG-17:00 | 2931.76 | 01-AUG-17:00 | 997.82 | 20-AUG-16:10 | 981.73 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.243282E+10 | 0.613334E+09 | 581.33 | 0.182352E+10 | 0.609299E+09 | 0.00 | 0.47 | 07-SEP-16:10 | 0.00 | 13-SEP-05:05 | 2914.86 | 07-SEP-16:10 | 2313.04 | 07-SEP-16:08 | 774.37 | 16-SEP-13:30 | 782.21 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.555830E+09 | 0.137994E+09 | 186.78 | 0.403981E+09 | 0.151849E+09 | 0.00 | 0.33 | 18-OCT-16:03 | 0.00 | 01-OCT-00:10 | 2104.35 | 18-OCT-16:03 | 1609.65 | 10-OCT-16:08 | 830.51 | 18-OCT-13:10 | 518.28 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 28217470.71 | 7054083.62 | 25.83 | 21547638.38 | 6669832.33 | 0.00 | 0.17 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1020.82 | 05-NOV-16:10 | 814.27 | 05-NOV-16:10 | 221.62 | 05-NOV-15:10 | 254.27 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 165035.50 | 42395.80 | 0.83 | 141036.91 | 23998.59 | 0.00 | 0.02 | 12-DEC-17:05 | 0.00 | 01-DEC-00:10 | 93.84 | 12-DEC-17:05 | 80.21 | 12-DEC-17:05 | 13.63 | 12-DEC-17:05 | 24.09 | 12-DEC-17:05 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.195230E+11 | 0.499622E+10 | 3832.09 | 0.148998E+11 | 0.462319E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.496511E+10 | 0.126658E+10 | 741.71 | 0.356947E+10 | 0.139564E+10 | 0.00 | 0.58 | 0.00 | 3494.18 | 2931.76 | 997.82 | 981.73 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 17201438.87 | 4560497.44 | 16.67 | 17201438.87 | 0.00 | 0.00 | 0.10 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 | 540.64 | 28-FEB-17:10 | 540.64 | 28-FEB-17:10 | 0.00 | 26-FEB-16:20 | 141.86 | 28-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.187436E+09 | 48058504.53 | 84.67 | 0.165291E+09 | 22145082.28 | 0.00 | 0.31 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 | 1821.03 | 30-MAR-16:10 | 1731.20 | 30-MAR-16:07 | 279.36 | 30-MAR-12:00 | 480.36 | 30-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.792139E+09 | 0.203650E+09 | 284.58 | 0.712515E+09 | 79623987.05 | 0.00 | 0.30 | 19-APR-15:10 | 0.00 | 01-APR-00:10 | 1760.37 | 19-APR-15:10 | 1674.89 | 17-APR-16:20 | 406.17 | 04-APR-14:10 | 456.64 | 19-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.203694E+10 | 0.518972E+09 | 514.47 | 0.169888E+10 | 0.338065E+09 | 0.00 | 0.42 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2570.04 | 30-MAY-15:10 | 2198.07 | 30-MAY-15:10 | 602.29 | 07-MAY-17:00 | 684.72 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.384384E+10 | 0.992550E+09 | 667.69 | 0.302061E+10 | 0.823224E+09 | 0.00 | 0.53 | 06-JUN-17:00 | 0.00 | 01-JUN-05:05 | 3228.18 | 23-JUN-17:00 | 2764.70 | 06-JUN-17:05 | 840.25 | 29-JUN-10:00 | 889.36 | 06-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.467911E+10 | 0.120706E+10 | 727.97 | 0.348014E+10 | 0.119897E+10 | 0.00 | 0.57 | 08-JUL-16:03 | 0.00 | 03-JUL-05:05 | 3460.70 | 15-JUL-16:40 | 2892.20 | 08-JUL-16:03 | 883.47 | 26-JUL-11:00 | 968.96 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.496617E+10 | 0.126668E+10 | 741.71 | 0.357017E+10 | 0.139600E+10 | 0.00 | 0.58 | 01-AUG-17:00 | 0.00 | 25-AUG-05:05 | 3483.82 | 01-AUG-17:00 | 2922.51 | 01-AUG-17:00 | 995.08 | 20-AUG-16:10 | 978.80 | 01-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 0.243548E+10 | 0.613957E+09 | 582.00 | 0.182570E+10 | 0.609787E+09 | 0.00 | 0.47 | 07-SEP-16:10 | 0.00 | 13-SEP-05:05 | 2908.45 | 07-SEP-16:10 | 2307.86 | 07-SEP-16:08 | 774.32 | 16-SEP-13:30 | 780.44 | 07-SEP-16:10 | 0.00 | 01-SEP-00:10 |
| October | 0.557587E+09 | 0.138427E+09 | 187.69 | 0.405396E+09 | 0.152191E+09 | 0.00 | 0.33 | 18-OCT-16:03 | 0.00 | 01-OCT-00:10 | 2104.43 | 18-OCT-16:03 | 1604.44 | 10-OCT-16:08 | 831.33 | 18-OCT-13:10 | 516.51 | 10-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 27990790.36 | 6997475.27 | 24.92 | 21368998.92 | 6621791.44 | 0.00 | 0.17 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 | 1009.94 | 05-NOV-16:10 | 805.11 | 05-NOV-16:10 | 220.32 | 05-NOV-15:10 | 251.59 | 05-NOV-16:10 | 0.00 | 01-NOV-00:10 |
| December | 152907.72 | 39281.22 | 0.83 | 130617.11 | 22290.62 | 0.00 | 0.02 | 12-DEC-17:05 | 0.00 | 01-DEC-00:10 | 91.05 | 12-DEC-17:05 | 77.81 | 12-DEC-17:05 | 13.25 | 12-DEC-17:05 | 23.38 | 12-DEC-17:05 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.195440E+11 | 0.500095E+10 | 3833.21 | 0.149174E+11 | 0.462665E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.496617E+10 | 0.126668E+10 | 741.71 | 0.357017E+10 | 0.139600E+10 | 0.00 | 0.58 | 0.00 | 3483.82 | 2922.51 | 995.08 | 978.80 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 4843597.05 | 1291357.25 | 7.00 | 4843597.05 | 0.00 | 0.00 | 0.09 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 | 521.51 | 29-JAN-15:00 | 521.51 | 29-JAN-15:00 | 0.00 | 29-JAN-17:04 | 138.09 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.142216E+09 | 37026225.38 | 53.92 | 0.142216E+09 | 0.00 | 0.00 | 0.31 | 26-FEB-15:10 | 0.00 | 01-FEB-00:10 | 1830.79 | 26-FEB-15:10 | 1830.79 | 26-FEB-15:10 | 0.00 | 21-FEB-15:20 | 472.11 | 26-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.441139E+09 | 0.113234E+09 | 174.97 | 0.409810E+09 | 31328896.27 | 0.00 | 0.41 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 | 2510.64 | 30-MAR-14:10 | 2364.47 | 30-MAR-15:10 | 368.07 | 30-MAR-11:50 | 651.45 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
| April | 0.110825E+10 | 0.283916E+09 | 318.17 | 0.101744E+10 | 90802619.85 | 0.00 | 0.39 | 16-APR-14:00 | 0.00 | 01-APR-00:10 | 2289.60 | 16-APR-14:00 | 2289.60 | 16-APR-14:00 | 478.64 | 04-APR-13:40 | 613.08 | 16-APR-14:00 | 0.00 | 01-APR-00:10 |
| May | 0.222498E+10 | 0.566271E+09 | 523.08 | 0.187505E+10 | 0.349931E+09 | 0.00 | 0.45 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2746.89 | 30-MAY-15:10 | 2455.00 | 19-MAY-16:05 | 645.32 | 07-MAY-17:00 | 730.32 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.387676E+10 | 0.100213E+10 | 666.81 | 0.305887E+10 | 0.817884E+09 | 0.00 | 0.55 | 25-JUN-16:02 | 0.00 | 01-JUN-05:05 | 3425.78 | 25-JUN-16:02 | 2851.97 | 24-JUN-16:04 | 847.27 | 23-JUN-12:00 | 937.75 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.475761E+10 | 0.122813E+10 | 729.33 | 0.355443E+10 | 0.120318E+10 | 0.00 | 0.60 | 08-JUL-16:03 | 0.00 | 03-JUL-05:05 | 3644.96 | 08-JUL-16:03 | 3142.91 | 08-JUL-16:03 | 912.35 | 26-JUL-11:10 | 1044.73 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.529384E+10 | 0.134971E+10 | 741.71 | 0.386838E+10 | 0.142547E+10 | 0.00 | 0.60 | 19-AUG-14:00 | 0.00 | 25-AUG-05:05 | 3748.32 | 19-AUG-16:10 | 3116.72 | 18-AUG-16:07 | 1057.73 | 20-AUG-16:10 | 1028.30 | 19-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.300339E+10 | 0.754876E+09 | 595.17 | 0.233928E+10 | 0.664103E+09 | 0.00 | 0.56 | 06-SEP-13:30 | 0.00 | 13-SEP-05:05 | 3596.90 | 06-SEP-13:30 | 2901.31 | 07-SEP-15:10 | 867.20 | 16-SEP-13:30 | 943.40 | 06-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 0.112522E+10 | 0.280800E+09 | 288.50 | 0.930124E+09 | 0.195092E+09 | 0.00 | 0.52 | 10-OCT-14:10 | 0.00 | 01-OCT-00:10 | 3224.24 | 11-OCT-14:10 | 2809.51 | 10-OCT-14:10 | 843.68 | 18-OCT-13:10 | 837.16 | 10-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.249883E+09 | 63855286.89 | 127.11 | 0.227231E+09 | 22651066.93 | 0.00 | 0.33 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 | 2094.26 | 05-NOV-15:30 | 1782.36 | 05-NOV-16:05 | 437.02 | 05-NOV-13:30 | 513.52 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 |
| December | 44577933.87 | 11492530.09 | 32.67 | 40898443.33 | 3679490.53 | 0.00 | 0.20 | 12-DEC-14:20 | 0.00 | 01-DEC-00:10 | 1250.97 | 12-DEC-14:20 | 1048.40 | 12-DEC-14:20 | 213.58 | 12-DEC-14:00 | 311.30 | 12-DEC-14:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.222727E+11 | 0.569273E+10 | 4258.43 | 0.174686E+11 | 0.480412E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 4843597.05 | 1291357.25 | 7.00 | 4843597.05 | 0.00 | 0.00 | 0.09 | 0.00 | 521.51 | 521.51 | 0.00 | 138.09 | 0.00 | |||||||
| Maximum of Months | 0.529384E+10 | 0.134971E+10 | 741.71 | 0.386838E+10 | 0.142547E+10 | 0.00 | 0.60 | 0.00 | 3748.32 | 3142.91 | 1057.73 | 1044.73 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 5165465.78 | 1376681.10 | 7.17 | 5165465.78 | 0.00 | 0.00 | 0.10 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 | 537.96 | 29-JAN-15:00 | 537.96 | 29-JAN-15:00 | 0.00 | 29-JAN-15:00 | 142.38 | 29-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 0.143877E+09 | 37451714.25 | 54.08 | 0.143877E+09 | -0.0 | 0.00 | 0.32 | 26-FEB-15:10 | 0.00 | 01-FEB-00:10 | 1841.61 | 26-FEB-15:10 | 1841.61 | 26-FEB-15:10 | 0.00 | 21-FEB-15:40 | 474.71 | 26-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.442405E+09 | 0.113558E+09 | 174.50 | 0.411025E+09 | 31380265.12 | 0.00 | 0.41 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 | 2514.48 | 30-MAR-14:10 | 2361.90 | 30-MAR-15:10 | 370.06 | 30-MAR-11:50 | 652.28 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 |
| April | 0.111133E+10 | 0.284679E+09 | 318.00 | 0.102048E+10 | 90853605.60 | 0.00 | 0.39 | 16-APR-14:00 | 0.00 | 01-APR-00:10 | 2302.48 | 16-APR-14:00 | 2302.48 | 16-APR-14:00 | 479.09 | 04-APR-13:40 | 616.21 | 16-APR-14:00 | 0.00 | 01-APR-00:10 |
| May | 0.222990E+10 | 0.567438E+09 | 523.75 | 0.187938E+10 | 0.350513E+09 | 0.00 | 0.45 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2749.44 | 30-MAY-15:10 | 2448.46 | 19-MAY-16:05 | 646.60 | 07-MAY-17:00 | 730.83 | 30-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.388129E+10 | 0.100314E+10 | 666.94 | 0.306278E+10 | 0.818509E+09 | 0.00 | 0.55 | 25-JUN-16:02 | 0.00 | 01-JUN-05:05 | 3418.12 | 25-JUN-16:02 | 2844.84 | 24-JUN-16:04 | 848.41 | 23-JUN-12:00 | 935.59 | 25-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.476167E+10 | 0.122894E+10 | 729.33 | 0.355753E+10 | 0.120414E+10 | 0.00 | 0.60 | 08-JUL-16:03 | 0.00 | 03-JUL-05:05 | 3638.91 | 08-JUL-16:03 | 3137.55 | 08-JUL-16:03 | 914.83 | 26-JUL-11:10 | 1042.86 | 08-JUL-16:03 | 0.00 | 01-JUL-00:10 |
| August | 0.529488E+10 | 0.134976E+10 | 741.71 | 0.386907E+10 | 0.142580E+10 | 0.00 | 0.60 | 19-AUG-14:00 | 0.00 | 25-AUG-05:05 | 3752.48 | 19-AUG-14:00 | 3109.62 | 18-AUG-16:07 | 1055.31 | 20-AUG-16:10 | 1029.68 | 19-AUG-14:00 | 0.00 | 01-AUG-00:10 |
| September | 0.300573E+10 | 0.755353E+09 | 595.33 | 0.234123E+10 | 0.664503E+09 | 0.00 | 0.57 | 06-SEP-13:30 | 0.00 | 13-SEP-05:05 | 3608.66 | 06-SEP-13:30 | 2903.44 | 07-SEP-15:10 | 867.15 | 16-SEP-13:30 | 946.06 | 06-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 0.112914E+10 | 0.281751E+09 | 289.17 | 0.933754E+09 | 0.195387E+09 | 0.00 | 0.52 | 10-OCT-14:10 | 0.00 | 01-OCT-00:10 | 3230.97 | 10-OCT-14:10 | 2816.64 | 10-OCT-14:10 | 844.45 | 18-OCT-13:10 | 838.64 | 10-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.251093E+09 | 64168034.64 | 127.54 | 0.228496E+09 | 22596741.66 | 0.00 | 0.33 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 | 2086.19 | 05-NOV-15:30 | 1772.26 | 05-NOV-16:05 | 437.18 | 05-NOV-13:30 | 511.55 | 05-NOV-15:30 | 0.00 | 01-NOV-00:10 |
| December | 44976144.99 | 11595863.05 | 32.67 | 41278125.39 | 3698019.60 | 0.00 | 0.20 | 12-DEC-14:20 | 0.00 | 01-DEC-00:10 | 1254.05 | 12-DEC-14:10 | 1050.68 | 12-DEC-14:20 | 214.27 | 12-DEC-14:00 | 311.92 | 12-DEC-14:20 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.223015E+11 | 0.569921E+10 | 4260.19 | 0.174941E+11 | 0.480739E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 5165465.78 | 1376681.10 | 7.17 | 5165465.78 | -0.0 | 0.00 | 0.10 | 0.00 | 537.96 | 537.96 | 0.00 | 142.38 | 0.00 | |||||||
| Maximum of Months | 0.529488E+10 | 0.134976E+10 | 741.71 | 0.386907E+10 | 0.142580E+10 | 0.00 | 0.60 | 0.00 | 3752.48 | 3137.55 | 1055.31 | 1042.86 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 184.19 | 192.17 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 195.18 | 158.77 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 192.15 | 101.96 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 166.62 | 84.16 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 138.54 | 55.73 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 151.45 | 34.16 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 160.66 | 22.13 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 192.04 | 17.87 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 183.63 | 49.22 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 217.43 | 106.76 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 213.86 | 137.42 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 196.29 | 162.89 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 182.61 | 93.26 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 138.54 | 17.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 217.43 | 192.17 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 45.09 | 21.02 | 24.07 | 35.22 | 144.05 | 0.00 | 0.00 | 0.00 |
| February | 51.41 | 24.04 | 27.37 | 53.79 | 116.13 | 0.00 | 0.00 | 0.00 |
| March | 75.60 | 36.47 | 39.13 | 98.99 | 69.54 | 0.00 | 0.00 | 0.00 |
| April | 85.02 | 38.83 | 46.19 | 128.28 | 54.73 | 0.00 | 0.00 | 0.00 |
| May | 85.67 | 32.49 | 53.18 | 141.01 | 36.17 | 0.00 | 0.00 | 0.00 |
| June | 90.20 | 34.84 | 55.37 | 167.52 | 22.22 | 0.00 | 0.00 | 0.00 |
| July | 84.82 | 31.42 | 53.40 | 164.10 | 14.36 | 0.00 | 0.00 | 0.00 |
| August | 83.12 | 31.06 | 52.07 | 161.20 | 11.71 | 0.00 | 0.00 | 0.00 |
| September | 67.97 | 28.40 | 39.57 | 112.39 | 32.43 | 0.00 | 0.00 | 0.00 |
| October | 60.17 | 31.15 | 29.02 | 81.73 | 74.73 | 0.00 | 0.00 | 0.00 |
| November | 47.92 | 21.37 | 26.55 | 52.19 | 100.23 | 0.00 | 0.00 | 0.00 |
| December | 39.85 | 17.49 | 22.37 | 33.28 | 121.92 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.16 | 29.07 | 39.09 | 102.74 | 66.26 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.85 | 17.49 | 22.37 | 33.28 | 11.71 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 90.20 | 38.83 | 55.37 | 167.52 | 144.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 45.09 | 21.02 | 24.07 | 36.64 | 141.03 | 0.00 | 0.00 | 0.00 |
| February | 51.41 | 24.04 | 27.37 | 56.00 | 112.64 | 0.00 | 0.00 | 0.00 |
| March | 75.60 | 36.47 | 39.13 | 102.58 | 65.34 | 0.00 | 0.00 | 0.00 |
| April | 85.02 | 38.83 | 46.19 | 130.47 | 52.67 | 0.00 | 0.00 | 0.00 |
| May | 85.67 | 32.49 | 53.18 | 141.62 | 35.70 | 0.00 | 0.00 | 0.00 |
| June | 90.20 | 34.84 | 55.37 | 167.60 | 22.25 | 0.00 | 0.00 | 0.00 |
| July | 84.82 | 31.42 | 53.40 | 164.23 | 14.34 | 0.00 | 0.00 | 0.00 |
| August | 83.12 | 31.06 | 52.07 | 161.80 | 11.49 | 0.00 | 0.00 | 0.00 |
| September | 67.97 | 28.40 | 39.57 | 113.39 | 31.75 | 0.00 | 0.00 | 0.00 |
| October | 60.17 | 31.15 | 29.02 | 83.91 | 71.16 | 0.00 | 0.00 | 0.00 |
| November | 47.92 | 21.37 | 26.55 | 55.78 | 93.09 | 0.00 | 0.00 | 0.00 |
| December | 39.85 | 17.49 | 22.37 | 35.58 | 117.05 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.16 | 29.07 | 39.09 | 104.39 | 63.80 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.85 | 17.49 | 22.37 | 35.58 | 11.49 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 90.20 | 38.83 | 55.37 | 167.60 | 141.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 4.55 | 233.23 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 16.22 | 182.37 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 39.28 | 102.90 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 71.30 | 80.43 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 102.53 | 52.03 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 143.38 | 31.64 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 145.15 | 21.03 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 131.49 | 16.99 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.12 | 48.93 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.77 | 110.92 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 16.42 | 147.10 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.74 | 188.40 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 65.19 | 100.93 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 4.55 | 16.99 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 145.15 | 233.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 190.93 | 167.79 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 198.41 | 145.96 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 189.10 | 105.99 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 161.25 | 91.82 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 130.96 | 66.75 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 138.29 | 50.53 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 142.85 | 41.38 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 175.59 | 38.87 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 172.65 | 69.99 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 211.89 | 119.08 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 211.79 | 142.85 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 198.72 | 156.09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 176.76 | 99.50 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 130.96 | 38.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 211.89 | 167.79 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.01 | 20.10 | 23.91 | 32.84 | 121.43 | 0.00 | 0.00 | 0.00 |
| February | 54.76 | 29.35 | 25.41 | 55.54 | 100.81 | 0.00 | 0.00 | 0.00 |
| March | 69.27 | 31.55 | 37.72 | 81.97 | 68.05 | 0.00 | 0.00 | 0.00 |
| April | 83.65 | 38.19 | 45.47 | 119.58 | 55.99 | 0.00 | 0.00 | 0.00 |
| May | 91.87 | 38.90 | 52.97 | 142.99 | 40.40 | 0.00 | 0.00 | 0.00 |
| June | 95.01 | 39.84 | 55.17 | 164.89 | 30.34 | 0.00 | 0.00 | 0.00 |
| July | 92.65 | 38.96 | 53.69 | 163.67 | 25.25 | 0.00 | 0.00 | 0.00 |
| August | 84.69 | 33.53 | 51.16 | 151.30 | 24.13 | 0.00 | 0.00 | 0.00 |
| September | 69.37 | 30.59 | 38.78 | 105.99 | 44.47 | 0.00 | 0.00 | 0.00 |
| October | 59.50 | 31.00 | 28.50 | 72.46 | 77.98 | 0.00 | 0.00 | 0.00 |
| November | 47.35 | 21.39 | 25.96 | 43.62 | 96.74 | 0.00 | 0.00 | 0.00 |
| December | 41.17 | 18.78 | 22.39 | 30.64 | 109.57 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.51 | 31.01 | 38.50 | 97.34 | 66.08 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.17 | 18.78 | 22.39 | 30.64 | 24.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 95.01 | 39.84 | 55.17 | 164.89 | 121.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.01 | 20.10 | 23.91 | 31.11 | 135.92 | 0.00 | 0.00 | 0.00 |
| February | 54.76 | 29.35 | 25.41 | 55.97 | 106.51 | 0.00 | 0.00 | 0.00 |
| March | 69.27 | 31.55 | 37.72 | 86.89 | 60.44 | 0.00 | 0.00 | 0.00 |
| April | 83.65 | 38.19 | 45.47 | 125.09 | 48.78 | 0.00 | 0.00 | 0.00 |
| May | 91.87 | 38.90 | 52.97 | 148.93 | 33.16 | 0.00 | 0.00 | 0.00 |
| June | 95.01 | 39.84 | 55.17 | 174.30 | 20.51 | 0.00 | 0.00 | 0.00 |
| July | 92.65 | 38.96 | 53.69 | 176.63 | 13.72 | 0.00 | 0.00 | 0.00 |
| August | 84.69 | 33.53 | 51.16 | 163.65 | 10.80 | 0.00 | 0.00 | 0.00 |
| September | 69.37 | 30.59 | 38.78 | 114.49 | 30.40 | 0.00 | 0.00 | 0.00 |
| October | 59.50 | 31.00 | 28.50 | 77.58 | 65.99 | 0.00 | 0.00 | 0.00 |
| November | 47.35 | 21.39 | 25.96 | 48.08 | 85.58 | 0.00 | 0.00 | 0.00 |
| December | 41.17 | 18.78 | 22.39 | 31.19 | 109.16 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.51 | 31.01 | 38.50 | 103.07 | 59.85 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.17 | 18.78 | 22.39 | 31.11 | 10.80 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 95.01 | 39.84 | 55.17 | 176.63 | 135.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 4.50 | 233.17 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 15.98 | 182.37 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 39.12 | 102.20 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 70.75 | 79.83 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 101.91 | 51.83 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 142.88 | 31.48 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 144.74 | 20.94 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 131.27 | 16.81 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 72.81 | 48.73 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.33 | 110.84 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 16.21 | 146.76 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.68 | 188.41 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 64.88 | 100.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 4.50 | 16.81 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 144.74 | 233.17 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 4.39 | 237.38 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 15.77 | 186.26 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 38.26 | 105.89 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 69.62 | 83.96 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 101.69 | 53.79 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 144.26 | 31.54 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 146.53 | 20.72 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 133.17 | 16.38 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.92 | 48.67 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.43 | 114.03 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 15.71 | 150.90 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.48 | 191.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 65.14 | 103.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 4.39 | 16.38 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 146.53 | 237.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 4.39 | 237.37 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 15.76 | 186.27 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 38.26 | 105.84 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 69.60 | 83.92 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 101.66 | 53.79 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 144.24 | 31.54 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 146.51 | 20.72 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 133.17 | 16.37 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.91 | 48.66 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.41 | 114.03 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 15.71 | 150.87 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.47 | 191.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 65.12 | 103.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 4.39 | 16.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 146.51 | 237.37 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 182.58 | 196.21 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 193.34 | 163.17 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 189.44 | 106.99 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 164.28 | 88.42 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 137.75 | 57.63 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 152.31 | 34.14 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 162.01 | 21.86 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 193.62 | 17.31 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 184.30 | 49.02 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 216.70 | 109.60 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 211.76 | 142.29 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 194.22 | 167.36 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 181.80 | 95.81 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 137.75 | 17.31 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 216.70 | 196.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 183.05 | 194.94 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 193.50 | 162.56 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 189.03 | 107.49 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 163.72 | 89.14 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 137.19 | 58.25 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 151.59 | 34.76 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 161.10 | 22.54 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 192.74 | 18.04 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 183.70 | 49.80 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 216.32 | 110.30 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 211.51 | 142.71 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 194.34 | 167.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 181.43 | 96.11 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 137.19 | 18.04 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 216.32 | 194.94 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 179.74 | 199.68 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 189.42 | 169.19 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 182.76 | 115.70 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 157.81 | 96.60 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 133.27 | 61.58 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 149.65 | 35.37 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 159.86 | 22.41 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 191.95 | 17.36 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 183.46 | 48.38 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 217.00 | 104.96 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 213.02 | 136.97 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 193.22 | 166.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 179.22 | 97.54 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 133.27 | 17.36 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 217.00 | 199.68 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 45.09 | 21.02 | 24.07 | 33.50 | 150.18 | 0.00 | 0.00 | 0.00 |
| February | 51.41 | 24.04 | 27.37 | 51.07 | 123.90 | 0.00 | 0.00 | 0.00 |
| March | 75.60 | 36.47 | 39.13 | 93.26 | 78.97 | 0.00 | 0.00 | 0.00 |
| April | 85.02 | 38.83 | 46.19 | 122.22 | 62.75 | 0.00 | 0.00 | 0.00 |
| May | 85.67 | 32.49 | 53.18 | 137.28 | 39.92 | 0.00 | 0.00 | 0.00 |
| June | 90.20 | 34.84 | 55.37 | 165.97 | 23.02 | 0.00 | 0.00 | 0.00 |
| July | 84.82 | 31.42 | 53.40 | 163.37 | 14.55 | 0.00 | 0.00 | 0.00 |
| August | 83.12 | 31.06 | 52.07 | 161.03 | 11.40 | 0.00 | 0.00 | 0.00 |
| September | 67.97 | 28.40 | 39.57 | 112.32 | 31.92 | 0.00 | 0.00 | 0.00 |
| October | 60.17 | 31.15 | 29.02 | 81.56 | 73.53 | 0.00 | 0.00 | 0.00 |
| November | 47.92 | 21.37 | 26.55 | 51.82 | 100.00 | 0.00 | 0.00 | 0.00 |
| December | 39.85 | 17.49 | 22.37 | 32.17 | 125.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.16 | 29.07 | 39.09 | 100.73 | 69.34 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.85 | 17.49 | 22.37 | 32.17 | 11.40 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 90.20 | 38.83 | 55.37 | 165.97 | 150.18 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 45.09 | 21.02 | 24.07 | 35.21 | 146.87 | 0.00 | 0.00 | 0.00 |
| February | 51.41 | 24.04 | 27.37 | 53.48 | 119.83 | 0.00 | 0.00 | 0.00 |
| March | 75.60 | 36.47 | 39.13 | 96.48 | 74.79 | 0.00 | 0.00 | 0.00 |
| April | 85.02 | 38.83 | 46.19 | 123.66 | 61.54 | 0.00 | 0.00 | 0.00 |
| May | 85.67 | 32.49 | 53.18 | 137.64 | 39.76 | 0.00 | 0.00 | 0.00 |
| June | 90.20 | 34.84 | 55.37 | 166.05 | 23.04 | 0.00 | 0.00 | 0.00 |
| July | 84.82 | 31.42 | 53.40 | 163.50 | 14.53 | 0.00 | 0.00 | 0.00 |
| August | 83.12 | 31.06 | 52.07 | 161.57 | 11.23 | 0.00 | 0.00 | 0.00 |
| September | 67.97 | 28.40 | 39.57 | 113.27 | 31.39 | 0.00 | 0.00 | 0.00 |
| October | 60.17 | 31.15 | 29.02 | 83.88 | 70.17 | 0.00 | 0.00 | 0.00 |
| November | 47.92 | 21.37 | 26.55 | 55.59 | 93.35 | 0.00 | 0.00 | 0.00 |
| December | 39.85 | 17.49 | 22.37 | 34.64 | 120.37 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.16 | 29.07 | 39.09 | 102.34 | 66.97 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.85 | 17.49 | 22.37 | 34.64 | 11.23 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 90.20 | 38.83 | 55.37 | 166.05 | 146.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.99 | 243.21 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 13.99 | 194.31 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 32.04 | 118.32 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 62.29 | 94.35 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 96.65 | 58.02 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 141.51 | 32.73 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 144.41 | 21.31 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 131.64 | 16.57 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.40 | 48.31 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 31.20 | 109.23 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 16.55 | 147.38 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.15 | 193.78 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 62.93 | 106.02 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.99 | 16.57 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 144.41 | 243.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 179.44 | 199.34 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 188.71 | 169.02 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 181.96 | 115.14 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 157.04 | 96.20 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 132.76 | 61.37 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 149.21 | 35.20 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 159.50 | 22.30 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 191.74 | 17.17 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 183.15 | 48.15 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 216.50 | 104.60 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 212.44 | 136.66 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 192.82 | 166.56 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 178.73 | 97.26 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 132.76 | 17.17 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 216.50 | 199.34 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.01 | 20.10 | 23.91 | 28.83 | 145.64 | 0.00 | 0.00 | 0.00 |
| February | 54.76 | 29.35 | 25.41 | 51.04 | 117.80 | 0.00 | 0.00 | 0.00 |
| March | 69.27 | 31.55 | 37.72 | 77.24 | 73.88 | 0.00 | 0.00 | 0.00 |
| April | 83.65 | 38.19 | 45.47 | 116.32 | 58.33 | 0.00 | 0.00 | 0.00 |
| May | 91.87 | 38.90 | 52.97 | 144.16 | 37.02 | 0.00 | 0.00 | 0.00 |
| June | 95.01 | 39.84 | 55.17 | 172.69 | 21.19 | 0.00 | 0.00 | 0.00 |
| July | 92.65 | 38.96 | 53.69 | 175.73 | 13.91 | 0.00 | 0.00 | 0.00 |
| August | 84.69 | 33.53 | 51.16 | 162.88 | 10.69 | 0.00 | 0.00 | 0.00 |
| September | 69.37 | 30.59 | 38.78 | 113.44 | 30.56 | 0.00 | 0.00 | 0.00 |
| October | 59.50 | 31.00 | 28.50 | 75.29 | 68.17 | 0.00 | 0.00 | 0.00 |
| November | 47.35 | 21.39 | 25.96 | 44.17 | 92.55 | 0.00 | 0.00 | 0.00 |
| December | 41.17 | 18.78 | 22.39 | 28.38 | 117.77 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.51 | 31.01 | 38.50 | 99.44 | 65.36 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.17 | 18.78 | 22.39 | 28.38 | 10.69 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 95.01 | 39.84 | 55.17 | 175.73 | 145.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.01 | 20.10 | 23.91 | 29.80 | 141.66 | 0.00 | 0.00 | 0.00 |
| February | 54.76 | 29.35 | 25.41 | 53.29 | 113.56 | 0.00 | 0.00 | 0.00 |
| March | 69.27 | 31.55 | 37.72 | 80.50 | 69.49 | 0.00 | 0.00 | 0.00 |
| April | 83.65 | 38.19 | 45.47 | 117.72 | 57.12 | 0.00 | 0.00 | 0.00 |
| May | 91.87 | 38.90 | 52.97 | 144.52 | 36.86 | 0.00 | 0.00 | 0.00 |
| June | 95.01 | 39.84 | 55.17 | 172.77 | 21.20 | 0.00 | 0.00 | 0.00 |
| July | 92.65 | 38.96 | 53.69 | 175.86 | 13.89 | 0.00 | 0.00 | 0.00 |
| August | 84.69 | 33.53 | 51.16 | 163.44 | 10.53 | 0.00 | 0.00 | 0.00 |
| September | 69.37 | 30.59 | 38.78 | 114.37 | 30.03 | 0.00 | 0.00 | 0.00 |
| October | 59.50 | 31.00 | 28.50 | 77.60 | 65.04 | 0.00 | 0.00 | 0.00 |
| November | 47.35 | 21.39 | 25.96 | 47.91 | 85.68 | 0.00 | 0.00 | 0.00 |
| December | 41.17 | 18.78 | 22.39 | 30.16 | 112.22 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.51 | 31.01 | 38.50 | 100.91 | 62.85 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.17 | 18.78 | 22.39 | 29.80 | 10.53 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 95.01 | 39.84 | 55.17 | 175.86 | 141.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.93 | 243.14 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 13.63 | 194.33 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 31.58 | 117.63 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 61.54 | 94.02 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 96.11 | 57.81 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 141.03 | 32.53 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 144.02 | 21.18 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 131.41 | 16.38 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.07 | 48.09 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.63 | 109.17 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 16.31 | 146.95 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.08 | 193.75 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 62.56 | 105.81 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.93 | 16.38 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 144.02 | 243.14 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.82 | 247.26 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 13.50 | 198.68 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 31.22 | 121.65 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 62.16 | 95.84 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 97.47 | 58.08 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 143.07 | 32.18 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 146.20 | 20.79 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 133.48 | 15.93 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 74.14 | 48.28 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.58 | 113.31 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 15.58 | 152.13 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 3.83 | 197.84 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 63.21 | 108.05 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.82 | 15.93 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 146.20 | 247.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.82 | 247.25 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 13.48 | 198.69 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 31.19 | 121.61 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 62.12 | 95.84 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 97.45 | 58.07 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 143.06 | 32.18 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 146.19 | 20.78 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 133.47 | 15.93 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 74.13 | 48.27 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 30.55 | 113.31 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 15.57 | 152.09 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 3.83 | 197.83 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 63.19 | 108.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.82 | 15.93 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 146.19 | 247.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 177.94 | 203.96 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 187.44 | 174.16 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 180.90 | 119.73 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 157.39 | 98.20 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 134.04 | 61.59 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 151.18 | 34.82 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 161.65 | 21.88 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 193.72 | 16.73 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 184.11 | 48.35 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 215.97 | 108.68 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 210.39 | 142.82 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 190.89 | 172.09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 178.76 | 99.85 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 134.04 | 16.73 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 215.97 | 203.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 177.93 | 203.95 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 187.41 | 174.16 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 180.86 | 119.71 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 157.35 | 98.19 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 134.02 | 61.58 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 151.17 | 34.82 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 161.64 | 21.88 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 193.72 | 16.73 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 184.10 | 48.34 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 215.96 | 108.65 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 210.37 | 142.81 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 190.87 | 172.09 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 178.74 | 99.85 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 134.02 | 16.73 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 215.96 | 203.95 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 179.93 | 191.55 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 189.89 | 160.24 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 184.26 | 105.15 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 158.66 | 87.40 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 131.63 | 57.10 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 145.81 | 33.78 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 155.24 | 21.73 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 187.12 | 16.87 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 181.62 | 44.94 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 218.81 | 93.49 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 215.50 | 125.05 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 194.02 | 157.78 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 178.48 | 90.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 131.63 | 16.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 218.81 | 191.55 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 45.09 | 21.02 | 24.07 | 32.97 | 144.17 | 0.00 | 0.00 | 0.00 |
| February | 51.41 | 24.04 | 27.37 | 50.57 | 117.15 | 0.00 | 0.00 | 0.00 |
| March | 75.60 | 36.47 | 39.13 | 93.39 | 71.17 | 0.00 | 0.00 | 0.00 |
| April | 85.02 | 38.83 | 46.19 | 122.37 | 56.29 | 0.00 | 0.00 | 0.00 |
| May | 85.67 | 32.49 | 53.18 | 136.00 | 36.81 | 0.00 | 0.00 | 0.00 |
| June | 90.20 | 34.84 | 55.37 | 163.09 | 21.87 | 0.00 | 0.00 | 0.00 |
| July | 84.82 | 31.42 | 53.40 | 160.19 | 14.06 | 0.00 | 0.00 | 0.00 |
| August | 83.12 | 31.06 | 52.07 | 157.77 | 11.04 | 0.00 | 0.00 | 0.00 |
| September | 67.97 | 28.40 | 39.57 | 110.88 | 29.42 | 0.00 | 0.00 | 0.00 |
| October | 60.17 | 31.15 | 29.02 | 81.57 | 64.70 | 0.00 | 0.00 | 0.00 |
| November | 47.92 | 21.37 | 26.55 | 52.24 | 90.85 | 0.00 | 0.00 | 0.00 |
| December | 39.85 | 17.49 | 22.37 | 31.83 | 118.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.16 | 29.07 | 39.09 | 99.67 | 64.39 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.85 | 17.49 | 22.37 | 31.83 | 11.04 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 90.20 | 38.83 | 55.37 | 163.09 | 144.17 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 45.09 | 21.02 | 24.07 | 35.42 | 141.26 | 0.00 | 0.00 | 0.00 |
| February | 51.41 | 24.04 | 27.37 | 53.58 | 114.36 | 0.00 | 0.00 | 0.00 |
| March | 75.60 | 36.47 | 39.13 | 97.04 | 68.72 | 0.00 | 0.00 | 0.00 |
| April | 85.02 | 38.83 | 46.19 | 124.31 | 55.44 | 0.00 | 0.00 | 0.00 |
| May | 85.67 | 32.49 | 53.18 | 136.54 | 36.68 | 0.00 | 0.00 | 0.00 |
| June | 90.20 | 34.84 | 55.37 | 163.20 | 21.94 | 0.00 | 0.00 | 0.00 |
| July | 84.82 | 31.42 | 53.40 | 160.38 | 14.07 | 0.00 | 0.00 | 0.00 |
| August | 83.12 | 31.06 | 52.07 | 158.52 | 10.93 | 0.00 | 0.00 | 0.00 |
| September | 67.97 | 28.40 | 39.57 | 112.37 | 28.85 | 0.00 | 0.00 | 0.00 |
| October | 60.17 | 31.15 | 29.02 | 85.14 | 62.11 | 0.00 | 0.00 | 0.00 |
| November | 47.92 | 21.37 | 26.55 | 56.46 | 86.85 | 0.00 | 0.00 | 0.00 |
| December | 39.85 | 17.49 | 22.37 | 34.99 | 114.71 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.16 | 29.07 | 39.09 | 101.75 | 62.73 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 39.85 | 17.49 | 22.37 | 34.99 | 10.93 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 90.20 | 38.83 | 55.37 | 163.20 | 141.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 4.07 | 234.58 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 14.21 | 186.10 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 33.33 | 109.30 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 63.58 | 85.20 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 95.63 | 53.82 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 138.00 | 31.54 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 140.05 | 20.80 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 127.30 | 16.22 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 72.30 | 44.56 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 33.42 | 97.05 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 17.96 | 137.52 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.54 | 185.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 62.31 | 99.72 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 4.07 | 16.22 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 140.05 | 234.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 179.43 | 190.96 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 188.86 | 159.72 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 182.96 | 104.03 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 157.17 | 86.40 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 130.53 | 56.60 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 144.96 | 33.46 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 154.70 | 21.51 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 186.81 | 16.59 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 180.95 | 44.48 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 217.55 | 92.83 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 214.56 | 124.36 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 193.39 | 157.23 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 177.60 | 90.32 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 130.53 | 16.59 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 217.55 | 190.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.01 | 20.10 | 23.91 | 29.35 | 140.44 | 0.00 | 0.00 | 0.00 |
| February | 54.76 | 29.35 | 25.41 | 51.59 | 112.00 | 0.00 | 0.00 | 0.00 |
| March | 69.27 | 31.55 | 37.72 | 78.61 | 67.12 | 0.00 | 0.00 | 0.00 |
| April | 83.65 | 38.19 | 45.47 | 117.42 | 52.83 | 0.00 | 0.00 | 0.00 |
| May | 91.87 | 38.90 | 52.97 | 143.30 | 34.57 | 0.00 | 0.00 | 0.00 |
| June | 95.01 | 39.84 | 55.17 | 170.11 | 20.39 | 0.00 | 0.00 | 0.00 |
| July | 92.65 | 38.96 | 53.69 | 172.51 | 13.49 | 0.00 | 0.00 | 0.00 |
| August | 84.69 | 33.53 | 51.16 | 159.56 | 10.36 | 0.00 | 0.00 | 0.00 |
| September | 69.37 | 30.59 | 38.78 | 112.20 | 28.34 | 0.00 | 0.00 | 0.00 |
| October | 59.50 | 31.00 | 28.50 | 76.67 | 60.90 | 0.00 | 0.00 | 0.00 |
| November | 47.35 | 21.39 | 25.96 | 45.95 | 84.67 | 0.00 | 0.00 | 0.00 |
| December | 41.17 | 18.78 | 22.39 | 29.28 | 111.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.51 | 31.01 | 38.50 | 99.13 | 61.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.17 | 18.78 | 22.39 | 29.28 | 10.36 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 95.01 | 39.84 | 55.17 | 172.51 | 140.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.01 | 20.10 | 23.91 | 30.42 | 136.29 | 0.00 | 0.00 | 0.00 |
| February | 54.76 | 29.35 | 25.41 | 53.97 | 108.54 | 0.00 | 0.00 | 0.00 |
| March | 69.27 | 31.55 | 37.72 | 81.93 | 63.99 | 0.00 | 0.00 | 0.00 |
| April | 83.65 | 38.19 | 45.47 | 119.15 | 51.80 | 0.00 | 0.00 | 0.00 |
| May | 91.87 | 38.90 | 52.97 | 143.82 | 34.43 | 0.00 | 0.00 | 0.00 |
| June | 95.01 | 39.84 | 55.17 | 170.21 | 20.43 | 0.00 | 0.00 | 0.00 |
| July | 92.65 | 38.96 | 53.69 | 172.70 | 13.49 | 0.00 | 0.00 | 0.00 |
| August | 84.69 | 33.53 | 51.16 | 160.33 | 10.25 | 0.00 | 0.00 | 0.00 |
| September | 69.37 | 30.59 | 38.78 | 113.63 | 27.76 | 0.00 | 0.00 | 0.00 |
| October | 59.50 | 31.00 | 28.50 | 80.04 | 58.03 | 0.00 | 0.00 | 0.00 |
| November | 47.35 | 21.39 | 25.96 | 49.67 | 79.81 | 0.00 | 0.00 | 0.00 |
| December | 41.17 | 18.78 | 22.39 | 31.10 | 107.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.51 | 31.01 | 38.50 | 100.83 | 59.07 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.17 | 18.78 | 22.39 | 30.42 | 10.25 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 95.01 | 39.84 | 55.17 | 172.70 | 136.29 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.98 | 234.44 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 13.72 | 185.86 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 32.51 | 107.98 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 62.15 | 84.27 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 94.48 | 53.30 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 137.10 | 31.17 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 139.47 | 20.56 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 126.95 | 15.93 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 71.57 | 44.11 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 32.25 | 96.33 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 17.53 | 136.63 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.41 | 184.91 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 61.62 | 99.20 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.98 | 15.93 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 139.47 | 234.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.99 | 238.35 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 14.23 | 189.08 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 33.53 | 110.45 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 63.95 | 86.80 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 96.54 | 54.75 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 139.92 | 31.40 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 142.35 | 20.58 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 129.71 | 15.81 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.22 | 45.28 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 33.47 | 98.99 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 17.82 | 139.83 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.37 | 188.21 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 63.04 | 101.19 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.99 | 15.81 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 142.35 | 238.35 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 30.14 | 0.00 | 30.14 | 3.98 | 238.34 | 0.00 | 0.00 | 0.00 |
| February | 33.41 | 0.00 | 33.41 | 14.18 | 189.06 | 0.00 | 0.00 | 0.00 |
| March | 46.92 | 0.00 | 46.92 | 33.45 | 110.34 | 0.00 | 0.00 | 0.00 |
| April | 56.81 | 0.30 | 56.51 | 63.85 | 86.73 | 0.00 | 0.00 | 0.00 |
| May | 67.86 | 2.12 | 65.74 | 96.47 | 54.72 | 0.00 | 0.00 | 0.00 |
| June | 74.42 | 4.68 | 69.75 | 139.87 | 31.38 | 0.00 | 0.00 | 0.00 |
| July | 70.48 | 3.43 | 67.05 | 142.32 | 20.56 | 0.00 | 0.00 | 0.00 |
| August | 62.82 | 0.79 | 62.03 | 129.70 | 15.80 | 0.00 | 0.00 | 0.00 |
| September | 47.40 | 0.02 | 47.38 | 73.18 | 45.25 | 0.00 | 0.00 | 0.00 |
| October | 36.02 | 0.00 | 36.02 | 33.37 | 98.94 | 0.00 | 0.00 | 0.00 |
| November | 32.23 | 0.00 | 32.23 | 17.78 | 139.74 | 0.00 | 0.00 | 0.00 |
| December | 27.87 | 0.00 | 27.87 | 4.36 | 188.20 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.95 | 0.95 | 48.00 | 62.99 | 101.15 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27.87 | 0.00 | 27.87 | 3.98 | 15.80 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 74.42 | 4.68 | 69.75 | 142.32 | 238.34 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 178.61 | 195.15 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 188.79 | 163.67 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 183.65 | 107.48 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 158.62 | 89.33 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 132.54 | 58.05 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 147.78 | 33.72 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 157.58 | 21.53 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 189.48 | 16.48 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 182.37 | 45.63 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 218.13 | 96.31 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 214.12 | 128.68 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 192.43 | 161.40 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 178.62 | 92.74 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 132.54 | 16.48 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 218.13 | 195.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 158.83 | 109.96 | 48.87 | 178.57 | 195.11 | 0.00 | 0.00 | 0.00 |
| February | 151.64 | 102.02 | 49.61 | 188.72 | 163.65 | 0.00 | 0.00 | 0.00 |
| March | 134.79 | 70.00 | 64.79 | 183.55 | 107.40 | 0.00 | 0.00 | 0.00 |
| April | 104.39 | 36.03 | 68.36 | 158.52 | 89.26 | 0.00 | 0.00 | 0.00 |
| May | 82.47 | 10.10 | 72.37 | 132.47 | 58.02 | 0.00 | 0.00 | 0.00 |
| June | 76.08 | 4.58 | 71.50 | 147.73 | 33.69 | 0.00 | 0.00 | 0.00 |
| July | 76.35 | 5.51 | 70.84 | 157.55 | 21.52 | 0.00 | 0.00 | 0.00 |
| August | 90.87 | 16.55 | 74.32 | 189.46 | 16.47 | 0.00 | 0.00 | 0.00 |
| September | 104.33 | 41.21 | 63.12 | 182.34 | 45.60 | 0.00 | 0.00 | 0.00 |
| October | 144.39 | 93.08 | 51.31 | 218.05 | 96.26 | 0.00 | 0.00 | 0.00 |
| November | 158.10 | 105.39 | 52.71 | 214.05 | 128.63 | 0.00 | 0.00 | 0.00 |
| December | 158.40 | 111.28 | 47.12 | 192.38 | 161.36 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 119.90 | 58.59 | 61.31 | 178.57 | 92.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 76.08 | 4.58 | 47.12 | 132.47 | 16.47 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 158.83 | 111.28 | 74.32 | 218.05 | 195.11 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 10.56 | 4.82 | 5.74 | 7.00 | 34.32 | 3.00 | 0.00 | 0.00 |
| February | 13.14 | 7.04 | 6.10 | 12.47 | 28.02 | 7.00 | 0.00 | 0.00 |
| March | 16.62 | 7.57 | 9.05 | 18.69 | 17.71 | 15.50 | 0.00 | 0.00 |
| April | 20.07 | 9.16 | 10.91 | 27.54 | 14.56 | 158.33 | 0.00 | 0.00 |
| May | 22.05 | 9.33 | 12.71 | 33.04 | 10.08 | 245.33 | 0.00 | 0.00 |
| June | 22.80 | 9.56 | 13.24 | 39.00 | 6.37 | 229.50 | 0.00 | 0.00 |
| July | 22.23 | 9.35 | 12.88 | 39.33 | 4.65 | 285.50 | 0.00 | 0.00 |
| August | 20.32 | 8.05 | 12.28 | 36.33 | 3.92 | 294.17 | 0.00 | 0.00 |
| September | 16.65 | 7.34 | 9.31 | 25.83 | 8.59 | 321.67 | 0.00 | 0.00 |
| October | 14.28 | 7.44 | 6.84 | 18.24 | 16.41 | 211.50 | 0.00 | 0.00 |
| November | 11.36 | 5.13 | 6.23 | 11.12 | 21.64 | 79.67 | 0.00 | 0.00 |
| December | 9.88 | 4.51 | 5.37 | 7.03 | 27.76 | 22.50 | 0.00 | 0.00 |
| Annual Sum or Average | 16.68 | 7.44 | 9.24 | 23.02 | 16.11 | 1873.67 | 0.00 | 0.00 |
| Minimum of Months | 9.88 | 4.51 | 5.37 | 7.00 | 3.92 | 3.00 | 0.00 | 0.00 |
| Maximum of Months | 22.80 | 9.56 | 13.24 | 39.33 | 34.32 | 321.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.45 | 14.36 | 17.09 | 22.75 | 91.97 | 1.00 | 0.00 | 0.00 |
| February | 39.13 | 20.98 | 18.16 | 39.54 | 75.38 | 0.17 | 0.00 | 0.00 |
| March | 49.50 | 22.54 | 26.96 | 58.82 | 48.31 | 0.00 | 0.00 | 0.00 |
| April | 59.78 | 27.29 | 32.49 | 84.76 | 40.49 | 4.17 | 0.00 | 0.00 |
| May | 65.66 | 27.80 | 37.86 | 100.42 | 28.84 | 21.17 | 0.00 | 0.00 |
| June | 67.90 | 28.47 | 39.43 | 115.73 | 19.86 | 38.00 | 0.00 | 0.00 |
| July | 66.21 | 27.84 | 38.37 | 116.01 | 15.05 | 83.67 | 0.00 | 0.00 |
| August | 60.52 | 23.96 | 36.56 | 106.75 | 13.42 | 111.00 | 0.00 | 0.00 |
| September | 49.58 | 21.86 | 27.72 | 75.63 | 27.86 | 46.83 | 0.00 | 0.00 |
| October | 42.52 | 22.15 | 20.37 | 52.34 | 52.74 | 20.33 | 0.00 | 0.00 |
| November | 33.84 | 15.29 | 18.55 | 32.43 | 66.36 | 10.50 | 0.00 | 0.00 |
| December | 29.42 | 13.42 | 16.00 | 22.02 | 78.90 | 1.67 | 0.00 | 0.00 |
| Annual Sum or Average | 49.68 | 22.16 | 27.52 | 69.08 | 46.45 | 338.50 | 0.00 | 0.00 |
| Minimum of Months | 29.42 | 13.42 | 16.00 | 22.02 | 13.42 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 67.90 | 28.47 | 39.43 | 116.01 | 91.97 | 111.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 10.56 | 4.82 | 5.74 | 6.46 | 37.64 | 34.67 | 0.00 | 0.00 |
| February | 13.14 | 7.04 | 6.10 | 11.70 | 30.81 | 37.33 | 0.00 | 0.00 |
| March | 16.62 | 7.57 | 9.05 | 17.50 | 19.86 | 67.83 | 0.00 | 0.00 |
| April | 20.07 | 9.16 | 10.91 | 26.41 | 16.04 | 261.83 | 0.00 | 0.00 |
| May | 22.05 | 9.33 | 12.71 | 32.63 | 10.66 | 324.83 | 0.00 | 0.00 |
| June | 22.80 | 9.56 | 13.24 | 39.24 | 6.52 | 276.83 | 0.00 | 0.00 |
| July | 22.23 | 9.35 | 12.88 | 39.85 | 4.67 | 302.50 | 0.00 | 0.00 |
| August | 20.32 | 8.05 | 12.28 | 36.88 | 3.90 | 304.17 | 0.00 | 0.00 |
| September | 16.65 | 7.34 | 9.31 | 25.64 | 9.17 | 381.17 | 0.00 | 0.00 |
| October | 14.28 | 7.44 | 6.84 | 17.07 | 18.69 | 345.83 | 0.00 | 0.00 |
| November | 11.36 | 5.13 | 6.23 | 9.97 | 24.36 | 180.33 | 0.00 | 0.00 |
| December | 9.88 | 4.51 | 5.37 | 6.32 | 30.82 | 64.33 | 0.00 | 0.00 |
| Annual Sum or Average | 16.68 | 7.44 | 9.24 | 22.53 | 17.70 | 2581.67 | 0.00 | 0.00 |
| Minimum of Months | 9.88 | 4.51 | 5.37 | 6.32 | 3.90 | 34.67 | 0.00 | 0.00 |
| Maximum of Months | 22.80 | 9.56 | 13.24 | 39.85 | 37.64 | 381.17 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.493339E+09 | 0.514718E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.472187E+09 | 0.384106E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.514647E+09 | 0.273099E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.431874E+09 | 0.218137E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.371065E+09 | 0.149276E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.392560E+09 | 88542029.64 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.430322E+09 | 59267411.02 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.514369E+09 | 47866394.74 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.475965E+09 | 0.127567E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.582354E+09 | 0.285959E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.554319E+09 | 0.356197E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.525732E+09 | 0.436290E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.575873E+10 | 0.294102E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.371065E+09 | 47866394.74 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.582354E+09 | 0.514718E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120771E+09 | 56313031.91 | 64458147.34 | 94324954.64 | 0.385812E+09 |
| February | 0.124373E+09 | 58154304.47 | 66218721.00 | 0.130126E+09 | 0.280946E+09 |
| March | 0.202495E+09 | 97694523.29 | 0.104800E+09 | 0.265133E+09 | 0.186265E+09 |
| April | 0.220381E+09 | 0.100660E+09 | 0.119721E+09 | 0.332493E+09 | 0.141851E+09 |
| May | 0.229470E+09 | 87024837.16 | 0.142446E+09 | 0.377681E+09 | 96867810.06 |
| June | 0.233803E+09 | 90295579.12 | 0.143508E+09 | 0.434209E+09 | 57582946.88 |
| July | 0.227185E+09 | 84166289.99 | 0.143019E+09 | 0.439531E+09 | 38452259.45 |
| August | 0.222640E+09 | 83177971.56 | 0.139462E+09 | 0.431762E+09 | 31368525.06 |
| September | 0.176179E+09 | 73606709.13 | 0.102572E+09 | 0.291305E+09 | 84065586.32 |
| October | 0.161170E+09 | 83434328.24 | 77735453.80 | 0.218915E+09 | 0.200159E+09 |
| November | 0.124218E+09 | 55388735.27 | 68829041.14 | 0.135274E+09 | 0.259804E+09 |
| December | 0.106747E+09 | 46844477.73 | 59902831.09 | 89133723.03 | 0.326546E+09 |
| Annual Sum or Average | 0.214943E+10 | 0.916761E+09 | 0.123267E+10 | 0.323989E+10 | 0.208972E+10 |
| Minimum of Months | 0.106747E+09 | 46844477.73 | 59902831.09 | 89133723.03 | 31368525.06 |
| Maximum of Months | 0.233803E+09 | 0.100660E+09 | 0.143508E+09 | 0.439531E+09 | 0.385812E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120771E+09 | 56313031.91 | 64458147.34 | 98142093.09 | 0.377741E+09 |
| February | 0.124373E+09 | 58154304.47 | 66218721.00 | 0.135480E+09 | 0.272505E+09 |
| March | 0.202495E+09 | 97694523.29 | 0.104800E+09 | 0.274737E+09 | 0.175013E+09 |
| April | 0.220381E+09 | 0.100660E+09 | 0.119721E+09 | 0.338179E+09 | 0.136523E+09 |
| May | 0.229470E+09 | 87024837.16 | 0.142446E+09 | 0.379325E+09 | 95619269.43 |
| June | 0.233803E+09 | 90295579.12 | 0.143508E+09 | 0.434422E+09 | 57661841.59 |
| July | 0.227185E+09 | 84166289.99 | 0.143019E+09 | 0.439877E+09 | 38398577.48 |
| August | 0.222640E+09 | 83177971.56 | 0.139462E+09 | 0.433358E+09 | 30777546.78 |
| September | 0.176179E+09 | 73606709.13 | 0.102572E+09 | 0.293911E+09 | 82306229.21 |
| October | 0.161170E+09 | 83434328.24 | 77735453.80 | 0.224749E+09 | 0.190582E+09 |
| November | 0.124218E+09 | 55388735.27 | 68829041.14 | 0.144577E+09 | 0.241285E+09 |
| December | 0.106747E+09 | 46844477.73 | 59902831.09 | 95291116.53 | 0.313511E+09 |
| Annual Sum or Average | 0.214943E+10 | 0.916761E+09 | 0.123267E+10 | 0.329205E+10 | 0.201192E+10 |
| Minimum of Months | 0.106747E+09 | 46844477.73 | 59902831.09 | 95291116.53 | 30777546.78 |
| Maximum of Months | 0.233803E+09 | 0.100660E+09 | 0.143508E+09 | 0.439877E+09 | 0.377741E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 12190663.97 | 0.624676E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 39240716.47 | 0.441200E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.105199E+09 | 0.275609E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.184813E+09 | 0.208472E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.274616E+09 | 0.139352E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.371648E+09 | 82001889.97 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.388766E+09 | 56314987.32 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.352190E+09 | 45507727.64 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.189523E+09 | 0.126827E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 82421500.89 | 0.297089E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 42563021.58 | 0.381277E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 12686770.96 | 0.504624E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.205586E+10 | 0.318295E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 12190663.97 | 45507727.64 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.388766E+09 | 0.624676E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.511381E+09 | 0.449402E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.479991E+09 | 0.353101E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.506487E+09 | 0.283876E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.417971E+09 | 0.238010E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.350774E+09 | 0.178796E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.358460E+09 | 0.130973E+09 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.382610E+09 | 0.110842E+09 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.470302E+09 | 0.104109E+09 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.447507E+09 | 0.181418E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.567525E+09 | 0.318950E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.548971E+09 | 0.370259E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.532256E+09 | 0.418066E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.557424E+10 | 0.313780E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.350774E+09 | 0.104109E+09 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.567525E+09 | 0.449402E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.117863E+09 | 53826816.83 | 64036606.61 | 87955836.71 | 0.325232E+09 |
| February | 0.132468E+09 | 71006560.18 | 61461519.81 | 0.134373E+09 | 0.243872E+09 |
| March | 0.185522E+09 | 84491138.33 | 0.101031E+09 | 0.219537E+09 | 0.182252E+09 |
| April | 0.216831E+09 | 98976089.63 | 0.117855E+09 | 0.309959E+09 | 0.145139E+09 |
| May | 0.246075E+09 | 0.104195E+09 | 0.141880E+09 | 0.382987E+09 | 0.108194E+09 |
| June | 0.246278E+09 | 0.103278E+09 | 0.143000E+09 | 0.427383E+09 | 78649475.47 |
| July | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.438386E+09 | 67625784.51 |
| August | 0.226821E+09 | 89799634.56 | 0.137021E+09 | 0.405243E+09 | 64622153.84 |
| September | 0.179818E+09 | 79289350.92 | 0.100529E+09 | 0.274724E+09 | 0.115258E+09 |
| October | 0.159367E+09 | 83019956.12 | 76346646.76 | 0.194066E+09 | 0.208851E+09 |
| November | 0.122728E+09 | 55443708.03 | 67284120.35 | 0.113062E+09 | 0.250758E+09 |
| December | 0.110258E+09 | 50296868.29 | 59960923.26 | 82056478.07 | 0.293478E+09 |
| Annual Sum or Average | 0.219218E+10 | 0.977978E+09 | 0.121421E+10 | 0.306973E+10 | 0.208393E+10 |
| Minimum of Months | 0.110258E+09 | 50296868.29 | 59960923.26 | 82056478.07 | 64622153.84 |
| Maximum of Months | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.438386E+09 | 0.325232E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.117863E+09 | 53826816.83 | 64036606.61 | 83338348.19 | 0.364046E+09 |
| February | 0.132468E+09 | 71006560.18 | 61461519.81 | 0.135409E+09 | 0.257669E+09 |
| March | 0.185522E+09 | 84491138.33 | 0.101031E+09 | 0.232727E+09 | 0.161888E+09 |
| April | 0.216831E+09 | 98976089.63 | 0.117855E+09 | 0.324236E+09 | 0.126433E+09 |
| May | 0.246075E+09 | 0.104195E+09 | 0.141880E+09 | 0.398901E+09 | 88821245.44 |
| June | 0.246278E+09 | 0.103278E+09 | 0.143000E+09 | 0.451789E+09 | 53174559.35 |
| July | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.473082E+09 | 36741428.52 |
| August | 0.226821E+09 | 89799634.56 | 0.137021E+09 | 0.438308E+09 | 28931242.87 |
| September | 0.179818E+09 | 79289350.92 | 0.100529E+09 | 0.296752E+09 | 78799434.45 |
| October | 0.159367E+09 | 83019956.12 | 76346646.76 | 0.207797E+09 | 0.176741E+09 |
| November | 0.122728E+09 | 55443708.03 | 67284120.35 | 0.124612E+09 | 0.221817E+09 |
| December | 0.110258E+09 | 50296868.29 | 59960923.26 | 83529441.49 | 0.292375E+09 |
| Annual Sum or Average | 0.219218E+10 | 0.977978E+09 | 0.121421E+10 | 0.325048E+10 | 0.188744E+10 |
| Minimum of Months | 0.110258E+09 | 50296868.29 | 59960923.26 | 83338348.19 | 28931242.87 |
| Maximum of Months | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.473082E+09 | 0.364046E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 12064012.19 | 0.624512E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 38663270.07 | 0.441191E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.104770E+09 | 0.273732E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.183382E+09 | 0.206911E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.272943E+09 | 0.138824E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.370352E+09 | 81598982.99 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.387665E+09 | 56081586.20 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.351594E+09 | 45030385.31 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.188734E+09 | 0.126312E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 81237746.48 | 0.296873E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 42023520.86 | 0.380415E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 12526983.31 | 0.504632E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.204596E+10 | 0.317611E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 12064012.19 | 45030385.31 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.387665E+09 | 0.624512E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 11770603.17 | 0.635786E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 38151475.09 | 0.450612E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.102472E+09 | 0.283624E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.180451E+09 | 0.217629E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.272360E+09 | 0.144067E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.373916E+09 | 81764403.93 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.392464E+09 | 55501382.57 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.356694E+09 | 43859517.72 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.191594E+09 | 0.126147E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 81512122.32 | 0.305417E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 40729277.31 | 0.391131E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 11986810.72 | 0.513898E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.205410E+10 | 0.324944E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 11770603.17 | 43859517.72 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.392464E+09 | 0.635786E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 11765606.67 | 0.635776E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 38114540.17 | 0.450629E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.102464E+09 | 0.283490E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.180398E+09 | 0.217522E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.272283E+09 | 0.144065E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.373865E+09 | 81759943.52 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.392419E+09 | 55501944.49 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.356672E+09 | 43844942.14 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.191566E+09 | 0.126133E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 81446529.68 | 0.305417E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 40709154.11 | 0.391057E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 11980551.18 | 0.513898E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.205368E+10 | 0.324910E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 11765606.67 | 43844942.14 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.392419E+09 | 0.635776E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.489031E+09 | 0.525523E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.467731E+09 | 0.394748E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.507396E+09 | 0.286551E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.425821E+09 | 0.229182E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.368937E+09 | 0.154366E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.394792E+09 | 88495123.63 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.433922E+09 | 58559847.26 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.518589E+09 | 46359765.56 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.477694E+09 | 0.127072E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.580402E+09 | 0.293542E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.548872E+09 | 0.368812E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.520191E+09 | 0.448261E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.573338E+10 | 0.302147E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.368937E+09 | 46359765.56 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.580402E+09 | 0.525523E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.490282E+09 | 0.522136E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.468120E+09 | 0.393275E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.506295E+09 | 0.287914E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.424361E+09 | 0.231047E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.367456E+09 | 0.156014E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.392931E+09 | 90108706.93 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.431500E+09 | 60381429.87 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.516234E+09 | 48305649.41 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.476159E+09 | 0.129089E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.579392E+09 | 0.295424E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.548239E+09 | 0.369911E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.520511E+09 | 0.447302E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.572148E+10 | 0.303091E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.367456E+09 | 48305649.41 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.579392E+09 | 0.522136E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.481423E+09 | 0.534817E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.458242E+09 | 0.409296E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.489495E+09 | 0.309878E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.409036E+09 | 0.250382E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.356943E+09 | 0.164941E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.387895E+09 | 91685989.82 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.428177E+09 | 60026116.18 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.514117E+09 | 46496927.66 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.475520E+09 | 0.125405E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.581226E+09 | 0.281134E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.552151E+09 | 0.355034E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.517515E+09 | 0.446892E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.565174E+10 | 0.307599E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.356943E+09 | 46496927.66 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.581226E+09 | 0.534817E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120771E+09 | 56313031.91 | 64458147.34 | 89719099.57 | 0.402232E+09 |
| February | 0.124373E+09 | 58154304.47 | 66218721.00 | 0.123558E+09 | 0.299740E+09 |
| March | 0.202495E+09 | 97694523.29 | 0.104800E+09 | 0.249799E+09 | 0.211514E+09 |
| April | 0.220381E+09 | 0.100660E+09 | 0.119721E+09 | 0.316785E+09 | 0.162654E+09 |
| May | 0.229470E+09 | 87024837.16 | 0.142446E+09 | 0.367682E+09 | 0.106920E+09 |
| June | 0.233803E+09 | 90295579.12 | 0.143508E+09 | 0.430190E+09 | 59676788.86 |
| July | 0.227185E+09 | 84166289.99 | 0.143019E+09 | 0.437562E+09 | 38965714.61 |
| August | 0.222640E+09 | 83177971.56 | 0.139462E+09 | 0.431297E+09 | 30528222.11 |
| September | 0.176179E+09 | 73606709.13 | 0.102572E+09 | 0.291138E+09 | 82737047.97 |
| October | 0.161170E+09 | 83434328.24 | 77735453.80 | 0.218462E+09 | 0.196931E+09 |
| November | 0.124218E+09 | 55388735.27 | 68829041.14 | 0.134329E+09 | 0.259211E+09 |
| December | 0.106747E+09 | 46844477.73 | 59902831.09 | 86176784.25 | 0.335463E+09 |
| Annual Sum or Average | 0.214943E+10 | 0.916761E+09 | 0.123267E+10 | 0.317670E+10 | 0.218657E+10 |
| Minimum of Months | 0.106747E+09 | 46844477.73 | 59902831.09 | 86176784.25 | 30528222.11 |
| Maximum of Months | 0.233803E+09 | 0.100660E+09 | 0.143508E+09 | 0.437562E+09 | 0.402232E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120771E+09 | 56313031.91 | 64458147.34 | 94314877.43 | 0.393387E+09 |
| February | 0.124373E+09 | 58154304.47 | 66218721.00 | 0.129377E+09 | 0.289897E+09 |
| March | 0.202495E+09 | 97694523.29 | 0.104800E+09 | 0.258405E+09 | 0.200322E+09 |
| April | 0.220381E+09 | 0.100660E+09 | 0.119721E+09 | 0.320525E+09 | 0.159518E+09 |
| May | 0.229470E+09 | 87024837.16 | 0.142446E+09 | 0.368664E+09 | 0.106488E+09 |
| June | 0.233803E+09 | 90295579.12 | 0.143508E+09 | 0.430413E+09 | 59729675.06 |
| July | 0.227185E+09 | 84166289.99 | 0.143019E+09 | 0.437920E+09 | 38910510.50 |
| August | 0.222640E+09 | 83177971.56 | 0.139462E+09 | 0.432748E+09 | 30086126.81 |
| September | 0.176179E+09 | 73606709.13 | 0.102572E+09 | 0.293586E+09 | 81350271.99 |
| October | 0.161170E+09 | 83434328.24 | 77735453.80 | 0.224656E+09 | 0.187941E+09 |
| November | 0.124218E+09 | 55388735.27 | 68829041.14 | 0.144102E+09 | 0.241951E+09 |
| December | 0.106747E+09 | 46844477.73 | 59902831.09 | 92768969.20 | 0.322397E+09 |
| Annual Sum or Average | 0.214943E+10 | 0.916761E+09 | 0.123267E+10 | 0.322748E+10 | 0.211198E+10 |
| Minimum of Months | 0.106747E+09 | 46844477.73 | 59902831.09 | 92768969.20 | 30086126.81 |
| Maximum of Months | 0.233803E+09 | 0.100660E+09 | 0.143508E+09 | 0.437920E+09 | 0.393387E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10679665.88 | 0.651418E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 33834001.72 | 0.470080E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 85821086.99 | 0.316901E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.161450E+09 | 0.244566E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.258881E+09 | 0.155413E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.366782E+09 | 84838267.35 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.386789E+09 | 57067795.93 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.352593E+09 | 44390968.01 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.190245E+09 | 0.125212E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 83575330.47 | 0.292575E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 42908047.26 | 0.382018E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 11114187.87 | 0.519016E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.198467E+10 | 0.334350E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10679665.88 | 44390968.01 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.386789E+09 | 0.651418E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.480607E+09 | 0.533917E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.456532E+09 | 0.408901E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.487358E+09 | 0.308393E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.407040E+09 | 0.249348E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.355577E+09 | 0.164375E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.386743E+09 | 91236748.39 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.427196E+09 | 59715584.25 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.513568E+09 | 46000790.56 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.474722E+09 | 0.124804E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.579864E+09 | 0.280157E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.550650E+09 | 0.354217E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.516440E+09 | 0.446118E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.563630E+10 | 0.306718E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.355577E+09 | 46000790.56 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.579864E+09 | 0.533917E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.117863E+09 | 53826816.83 | 64036606.61 | 77230893.03 | 0.390076E+09 |
| February | 0.132468E+09 | 71006560.18 | 61461519.81 | 0.123467E+09 | 0.284987E+09 |
| March | 0.185522E+09 | 84491138.33 | 0.101031E+09 | 0.206885E+09 | 0.197870E+09 |
| April | 0.216831E+09 | 98976089.63 | 0.117855E+09 | 0.301499E+09 | 0.151180E+09 |
| May | 0.246075E+09 | 0.104195E+09 | 0.141880E+09 | 0.386115E+09 | 99167630.34 |
| June | 0.246278E+09 | 0.103278E+09 | 0.143000E+09 | 0.447612E+09 | 54928562.80 |
| July | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.470663E+09 | 37262359.27 |
| August | 0.226821E+09 | 89799634.56 | 0.137021E+09 | 0.436263E+09 | 28636129.38 |
| September | 0.179818E+09 | 79289350.92 | 0.100529E+09 | 0.294025E+09 | 79212176.09 |
| October | 0.159367E+09 | 83019956.12 | 76346646.76 | 0.201663E+09 | 0.182580E+09 |
| November | 0.122728E+09 | 55443708.03 | 67284120.35 | 0.114499E+09 | 0.239891E+09 |
| December | 0.110258E+09 | 50296868.29 | 59960923.26 | 76010230.15 | 0.315427E+09 |
| Annual Sum or Average | 0.219218E+10 | 0.977978E+09 | 0.121421E+10 | 0.313593E+10 | 0.206122E+10 |
| Minimum of Months | 0.110258E+09 | 50296868.29 | 59960923.26 | 76010230.15 | 28636129.38 |
| Maximum of Months | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.470663E+09 | 0.390076E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.117863E+09 | 53826816.83 | 64036606.61 | 79825898.07 | 0.379412E+09 |
| February | 0.132468E+09 | 71006560.18 | 61461519.81 | 0.128911E+09 | 0.274727E+09 |
| March | 0.185522E+09 | 84491138.33 | 0.101031E+09 | 0.215602E+09 | 0.186131E+09 |
| April | 0.216831E+09 | 98976089.63 | 0.117855E+09 | 0.305135E+09 | 0.148067E+09 |
| May | 0.246075E+09 | 0.104195E+09 | 0.141880E+09 | 0.387089E+09 | 98730736.75 |
| June | 0.246278E+09 | 0.103278E+09 | 0.143000E+09 | 0.447823E+09 | 54938315.65 |
| July | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.471018E+09 | 37190860.96 |
| August | 0.226821E+09 | 89799634.56 | 0.137021E+09 | 0.437750E+09 | 28201379.49 |
| September | 0.179818E+09 | 79289350.92 | 0.100529E+09 | 0.296456E+09 | 77848442.40 |
| October | 0.159367E+09 | 83019956.12 | 76346646.76 | 0.207831E+09 | 0.174199E+09 |
| November | 0.122728E+09 | 55443708.03 | 67284120.35 | 0.124184E+09 | 0.222072E+09 |
| December | 0.110258E+09 | 50296868.29 | 59960923.26 | 80777811.93 | 0.300583E+09 |
| Annual Sum or Average | 0.219218E+10 | 0.977978E+09 | 0.121421E+10 | 0.318240E+10 | 0.198210E+10 |
| Minimum of Months | 0.110258E+09 | 50296868.29 | 59960923.26 | 79825898.07 | 28201379.49 |
| Maximum of Months | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.471018E+09 | 0.379412E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10531210.51 | 0.651234E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 32984568.12 | 0.470129E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 84579223.82 | 0.315067E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.159517E+09 | 0.243699E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.257434E+09 | 0.154840E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.365547E+09 | 84316974.98 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.385738E+09 | 56721551.02 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.351978E+09 | 43876067.62 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.189405E+09 | 0.124648E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 82038025.32 | 0.292404E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 42276169.60 | 0.380894E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 10936500.45 | 0.518941E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.197296E+10 | 0.333677E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10531210.51 | 43876067.62 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.385738E+09 | 0.651234E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10236281.52 | 0.662259E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 32664190.65 | 0.480639E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 83610672.25 | 0.325829E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.161131E+09 | 0.248428E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.261056E+09 | 0.155549E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.370844E+09 | 83423088.73 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.391587E+09 | 55676832.37 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.357503E+09 | 42676123.90 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.192178E+09 | 0.125139E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 81907480.19 | 0.303489E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 40392981.00 | 0.394319E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 10271192.53 | 0.529886E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.199338E+10 | 0.340731E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10236281.52 | 42676123.90 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.391587E+09 | 0.662259E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10229156.48 | 0.662247E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 32603978.07 | 0.480676E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 83537494.56 | 0.325724E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.161023E+09 | 0.248421E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.261001E+09 | 0.155533E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.370802E+09 | 83410065.49 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.391550E+09 | 55669618.78 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.357481E+09 | 42659026.00 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.192147E+09 | 0.125120E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 81812166.29 | 0.303500E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 40367229.24 | 0.394219E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 10264033.16 | 0.529881E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.199282E+10 | 0.340706E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10229156.48 | 42659026.00 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.391550E+09 | 0.662247E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.476602E+09 | 0.546286E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.453459E+09 | 0.421318E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.484514E+09 | 0.320676E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.407943E+09 | 0.254534E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.359004E+09 | 0.164959E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.391871E+09 | 90262311.28 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.432960E+09 | 58614845.74 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.518873E+09 | 44821505.69 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.477221E+09 | 0.125321E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.578465E+09 | 0.291077E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.545336E+09 | 0.370188E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.511279E+09 | 0.460936E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.563753E+10 | 0.314899E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.359004E+09 | 44821505.69 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.578465E+09 | 0.546286E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.476559E+09 | 0.546252E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.453373E+09 | 0.421336E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.484419E+09 | 0.320623E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.407850E+09 | 0.254518E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.358953E+09 | 0.164941E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.391829E+09 | 90249877.56 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.432924E+09 | 58607543.13 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.518852E+09 | 44804189.23 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.477196E+09 | 0.125303E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.578426E+09 | 0.291019E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.545272E+09 | 0.370175E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.511219E+09 | 0.460925E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.563687E+10 | 0.314875E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.358953E+09 | 44804189.23 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.578426E+09 | 0.546252E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.481938E+09 | 0.513045E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.459383E+09 | 0.387649E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.493525E+09 | 0.281621E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.411247E+09 | 0.226532E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.352557E+09 | 0.152940E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.377949E+09 | 87557109.30 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.415799E+09 | 58194754.66 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.501188E+09 | 45176647.93 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.470749E+09 | 0.116484E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.586054E+09 | 0.250413E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.558578E+09 | 0.324129E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.519663E+09 | 0.422592E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.562863E+10 | 0.286633E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.352557E+09 | 45176647.93 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.586054E+09 | 0.513045E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120771E+09 | 56313031.91 | 64458147.34 | 88312987.00 | 0.386143E+09 |
| February | 0.124373E+09 | 58154304.47 | 66218721.00 | 0.122347E+09 | 0.283403E+09 |
| March | 0.202495E+09 | 97694523.29 | 0.104800E+09 | 0.250128E+09 | 0.190628E+09 |
| April | 0.220381E+09 | 0.100660E+09 | 0.119721E+09 | 0.317181E+09 | 0.145915E+09 |
| May | 0.229470E+09 | 87024837.16 | 0.142446E+09 | 0.364251E+09 | 98579187.85 |
| June | 0.233803E+09 | 90295579.12 | 0.143508E+09 | 0.422734E+09 | 56687629.29 |
| July | 0.227185E+09 | 84166289.99 | 0.143019E+09 | 0.429047E+09 | 37647877.77 |
| August | 0.222640E+09 | 83177971.56 | 0.139462E+09 | 0.422566E+09 | 29580967.74 |
| September | 0.176179E+09 | 73606709.13 | 0.102572E+09 | 0.287410E+09 | 76266403.19 |
| October | 0.161170E+09 | 83434328.24 | 77735453.80 | 0.218474E+09 | 0.173283E+09 |
| November | 0.124218E+09 | 55388735.27 | 68829041.14 | 0.135395E+09 | 0.235478E+09 |
| December | 0.106747E+09 | 46844477.73 | 59902831.09 | 85253576.62 | 0.316857E+09 |
| Annual Sum or Average | 0.214943E+10 | 0.916761E+09 | 0.123267E+10 | 0.314310E+10 | 0.203047E+10 |
| Minimum of Months | 0.106747E+09 | 46844477.73 | 59902831.09 | 85253576.62 | 29580967.74 |
| Maximum of Months | 0.233803E+09 | 0.100660E+09 | 0.143508E+09 | 0.429047E+09 | 0.386143E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.120771E+09 | 56313031.91 | 64458147.34 | 94878411.27 | 0.378362E+09 |
| February | 0.124373E+09 | 58154304.47 | 66218721.00 | 0.129613E+09 | 0.276663E+09 |
| March | 0.202495E+09 | 97694523.29 | 0.104800E+09 | 0.259901E+09 | 0.184072E+09 |
| April | 0.220381E+09 | 0.100660E+09 | 0.119721E+09 | 0.322220E+09 | 0.143701E+09 |
| May | 0.229470E+09 | 87024837.16 | 0.142446E+09 | 0.365702E+09 | 98254175.13 |
| June | 0.233803E+09 | 90295579.12 | 0.143508E+09 | 0.423009E+09 | 56860683.23 |
| July | 0.227185E+09 | 84166289.99 | 0.143019E+09 | 0.429553E+09 | 37678019.82 |
| August | 0.222640E+09 | 83177971.56 | 0.139462E+09 | 0.424585E+09 | 29281711.15 |
| September | 0.176179E+09 | 73606709.13 | 0.102572E+09 | 0.291261E+09 | 74791793.83 |
| October | 0.161170E+09 | 83434328.24 | 77735453.80 | 0.228043E+09 | 0.166344E+09 |
| November | 0.124218E+09 | 55388735.27 | 68829041.14 | 0.146341E+09 | 0.225119E+09 |
| December | 0.106747E+09 | 46844477.73 | 59902831.09 | 93720430.21 | 0.307227E+09 |
| Annual Sum or Average | 0.214943E+10 | 0.916761E+09 | 0.123267E+10 | 0.320883E+10 | 0.197836E+10 |
| Minimum of Months | 0.106747E+09 | 46844477.73 | 59902831.09 | 93720430.21 | 29281711.15 |
| Maximum of Months | 0.233803E+09 | 0.100660E+09 | 0.143508E+09 | 0.429553E+09 | 0.378362E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10910428.30 | 0.628310E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 34384808.32 | 0.450214E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 89266879.44 | 0.292743E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.164809E+09 | 0.220849E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.256143E+09 | 0.144155E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.357709E+09 | 81761945.98 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.375121E+09 | 55721212.05 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.340960E+09 | 43436467.94 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.187408E+09 | 0.115499E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 89516705.67 | 0.259934E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 46542600.34 | 0.356451E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 12148902.41 | 0.495592E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.196492E+10 | 0.314467E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10910428.30 | 43436467.94 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.375121E+09 | 0.628310E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.480580E+09 | 0.511456E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.456891E+09 | 0.386386E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.490053E+09 | 0.278626E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.407391E+09 | 0.223954E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.349615E+09 | 0.151584E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.375743E+09 | 86727663.17 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.414338E+09 | 57612215.14 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.500351E+09 | 44433320.41 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.469033E+09 | 0.115301E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.582680E+09 | 0.248631E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.556152E+09 | 0.322342E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.517970E+09 | 0.421131E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.560080E+10 | 0.284818E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.349615E+09 | 44433320.41 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.582680E+09 | 0.511456E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.117863E+09 | 53826816.83 | 64036606.61 | 78611508.14 | 0.376155E+09 |
| February | 0.132468E+09 | 71006560.18 | 61461519.81 | 0.124814E+09 | 0.270952E+09 |
| March | 0.185522E+09 | 84491138.33 | 0.101031E+09 | 0.210542E+09 | 0.179779E+09 |
| April | 0.216831E+09 | 98976089.63 | 0.117855E+09 | 0.304360E+09 | 0.136934E+09 |
| May | 0.246075E+09 | 0.104195E+09 | 0.141880E+09 | 0.383821E+09 | 92596686.10 |
| June | 0.246278E+09 | 0.103278E+09 | 0.143000E+09 | 0.440923E+09 | 52863457.34 |
| July | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.462060E+09 | 36140668.27 |
| August | 0.226821E+09 | 89799634.56 | 0.137021E+09 | 0.427371E+09 | 27747175.51 |
| September | 0.179818E+09 | 79289350.92 | 0.100529E+09 | 0.290825E+09 | 73467730.52 |
| October | 0.159367E+09 | 83019956.12 | 76346646.76 | 0.205341E+09 | 0.163125E+09 |
| November | 0.122728E+09 | 55443708.03 | 67284120.35 | 0.119097E+09 | 0.219469E+09 |
| December | 0.110258E+09 | 50296868.29 | 59960923.26 | 78436319.23 | 0.299641E+09 |
| Annual Sum or Average | 0.219218E+10 | 0.977978E+09 | 0.121421E+10 | 0.312620E+10 | 0.192887E+10 |
| Minimum of Months | 0.110258E+09 | 50296868.29 | 59960923.26 | 78436319.23 | 27747175.51 |
| Maximum of Months | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.462060E+09 | 0.376155E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.117863E+09 | 53826816.83 | 64036606.61 | 81465574.26 | 0.365029E+09 |
| February | 0.132468E+09 | 71006560.18 | 61461519.81 | 0.130572E+09 | 0.262585E+09 |
| March | 0.185522E+09 | 84491138.33 | 0.101031E+09 | 0.219438E+09 | 0.171379E+09 |
| April | 0.216831E+09 | 98976089.63 | 0.117855E+09 | 0.308844E+09 | 0.134272E+09 |
| May | 0.246075E+09 | 0.104195E+09 | 0.141880E+09 | 0.385212E+09 | 92223036.12 |
| June | 0.246278E+09 | 0.103278E+09 | 0.143000E+09 | 0.441184E+09 | 52963653.67 |
| July | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.462569E+09 | 36139093.74 |
| August | 0.226821E+09 | 89799634.56 | 0.137021E+09 | 0.429425E+09 | 27441397.16 |
| September | 0.179818E+09 | 79289350.92 | 0.100529E+09 | 0.294523E+09 | 71956365.07 |
| October | 0.159367E+09 | 83019956.12 | 76346646.76 | 0.214383E+09 | 0.155436E+09 |
| November | 0.122728E+09 | 55443708.03 | 67284120.35 | 0.128739E+09 | 0.206871E+09 |
| December | 0.110258E+09 | 50296868.29 | 59960923.26 | 83308518.61 | 0.286578E+09 |
| Annual Sum or Average | 0.219218E+10 | 0.977978E+09 | 0.121421E+10 | 0.317966E+10 | 0.186287E+10 |
| Minimum of Months | 0.110258E+09 | 50296868.29 | 59960923.26 | 81465574.26 | 27441397.16 |
| Maximum of Months | 0.248155E+09 | 0.104355E+09 | 0.143801E+09 | 0.462569E+09 | 0.365029E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10652855.03 | 0.627936E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 33180536.51 | 0.449624E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 87084987.92 | 0.289208E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.161083E+09 | 0.218433E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.253063E+09 | 0.142769E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.355370E+09 | 80795999.81 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.373547E+09 | 55066010.85 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.340014E+09 | 42663903.30 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.185513E+09 | 0.114336E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 86368725.70 | 0.258006E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 45439379.90 | 0.354151E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 11799941.18 | 0.495264E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.194312E+10 | 0.312825E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10652855.03 | 42663903.30 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.373547E+09 | 0.627936E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10689248.10 | 0.638385E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 34418390.88 | 0.457418E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 89806600.35 | 0.295835E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.165763E+09 | 0.224991E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.258569E+09 | 0.146647E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.362663E+09 | 81398022.38 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.381268E+09 | 55111344.81 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.347426E+09 | 42355721.05 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.189794E+09 | 0.117358E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 89632674.98 | 0.265142E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 46191832.73 | 0.362447E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 11699347.31 | 0.504106E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.198792E+10 | 0.319119E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10689248.10 | 42355721.05 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.381268E+09 | 0.638385E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80736292.62 | 0.00 | 80736292.62 | 10673111.02 | 0.638358E+09 |
| February | 80828105.99 | 0.00 | 80828105.99 | 34313560.08 | 0.457374E+09 |
| March | 0.125673E+09 | 6696.11 | 0.125666E+09 | 89600871.53 | 0.295528E+09 |
| April | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.165492E+09 | 0.224797E+09 |
| May | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.258387E+09 | 0.146558E+09 |
| June | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.362542E+09 | 81345948.73 |
| July | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.381196E+09 | 55076677.96 |
| August | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.347377E+09 | 42312211.53 |
| September | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.189687E+09 | 0.117286E+09 |
| October | 96464614.35 | 0.00 | 96464614.35 | 89367590.92 | 0.265009E+09 |
| November | 83547509.06 | 0.00 | 83547509.06 | 46097544.46 | 0.362216E+09 |
| December | 74634708.72 | 0.00 | 74634708.72 | 11674645.94 | 0.504069E+09 |
| Annual Sum or Average | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.198641E+10 | 0.318993E+10 |
| Minimum of Months | 74634708.72 | 0.00 | 74634708.72 | 10673111.02 | 42312211.53 |
| Maximum of Months | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.381196E+09 | 0.638358E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.478387E+09 | 0.522688E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.456730E+09 | 0.395954E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.491891E+09 | 0.287879E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.411139E+09 | 0.231552E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.354984E+09 | 0.155486E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.383036E+09 | 87389472.06 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.422063E+09 | 57663093.55 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.507505E+09 | 44145566.97 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.472712E+09 | 0.118264E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.584228E+09 | 0.257947E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.554996E+09 | 0.333546E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.515401E+09 | 0.432289E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.563307E+10 | 0.292480E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.354984E+09 | 44145566.97 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.584228E+09 | 0.522688E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.478277E+09 | 0.522582E+09 |
| February | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.456558E+09 | 0.395894E+09 |
| March | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.491628E+09 | 0.287669E+09 |
| April | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.410888E+09 | 0.231357E+09 |
| May | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.354811E+09 | 0.155392E+09 |
| June | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.382915E+09 | 87336351.16 |
| July | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.421991E+09 | 57628271.86 |
| August | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.507460E+09 | 44101903.18 |
| September | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.472628E+09 | 0.118195E+09 |
| October | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.584020E+09 | 0.257830E+09 |
| November | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.554828E+09 | 0.333419E+09 |
| December | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.515262E+09 | 0.432191E+09 |
| Annual Sum or Average | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.563127E+10 | 0.292360E+10 |
| Minimum of Months | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.354811E+09 | 44101903.18 |
| Maximum of Months | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.584020E+09 | 0.522582E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 28281808.21 | 12915963.80 | 15365844.41 | 18742165.08 | 91909737.13 |
| February | 31786254.99 | 17038313.14 | 14747941.85 | 30166779.84 | 67785517.75 |
| March | 44516708.42 | 20273992.56 | 24242715.87 | 50072464.66 | 47423853.37 |
| April | 52029480.59 | 23749715.58 | 28279765.02 | 71396166.29 | 37738480.40 |
| May | 59046655.09 | 25001956.46 | 34044698.63 | 88482797.22 | 27007667.90 |
| June | 59095323.58 | 24781941.39 | 34313382.19 | 0.101097E+09 | 16520706.21 |
| July | 59545920.41 | 25040374.86 | 34505545.55 | 0.105353E+09 | 12453138.16 |
| August | 54426599.54 | 21547787.83 | 32878811.70 | 97311383.53 | 10488552.20 |
| September | 43148161.42 | 19025802.49 | 24122358.93 | 66940833.25 | 22260954.50 |
| October | 38240665.04 | 19920976.39 | 18319688.65 | 48866819.33 | 43953404.90 |
| November | 29449041.97 | 13303943.42 | 16145098.55 | 28828759.83 | 56091228.05 |
| December | 26456805.88 | 12068938.28 | 14387867.60 | 18838314.54 | 74363332.00 |
| Annual Sum or Average | 0.526023E+09 | 0.234670E+09 | 0.291354E+09 | 0.726096E+09 | 0.507997E+09 |
| Minimum of Months | 26456805.88 | 12068938.28 | 14387867.60 | 18742165.08 | 10488552.20 |
| Maximum of Months | 59545920.41 | 25040374.86 | 34505545.55 | 0.105353E+09 | 91909737.13 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 84230263.14 | 38466954.49 | 45763308.65 | 60923654.99 | 0.246330E+09 |
| February | 94667377.79 | 50744336.74 | 43923041.05 | 95643736.49 | 0.182366E+09 |
| March | 0.132582E+09 | 60380995.28 | 72200840.98 | 0.157544E+09 | 0.129384E+09 |
| April | 0.154957E+09 | 70732563.43 | 84224178.01 | 0.219697E+09 | 0.104955E+09 |
| May | 0.175856E+09 | 74462048.41 | 0.101394E+09 | 0.268958E+09 | 77236389.44 |
| June | 0.176001E+09 | 73806788.78 | 0.102194E+09 | 0.299966E+09 | 51487601.77 |
| July | 0.177343E+09 | 74576467.96 | 0.102766E+09 | 0.310716E+09 | 40309030.38 |
| August | 0.162096E+09 | 64174674.62 | 97921283.58 | 0.285923E+09 | 35953389.75 |
| September | 0.128506E+09 | 56663574.65 | 71842388.06 | 0.196031E+09 | 72204608.61 |
| October | 0.113890E+09 | 59329625.30 | 54560591.90 | 0.140201E+09 | 0.141270E+09 |
| November | 87706575.77 | 39622454.37 | 48084121.41 | 84050077.21 | 0.172013E+09 |
| December | 78794952.03 | 35944301.70 | 42850650.33 | 58988828.51 | 0.211324E+09 |
| Annual Sum or Average | 0.156663E+10 | 0.698905E+09 | 0.867724E+09 | 0.217864E+10 | 0.146483E+10 |
| Minimum of Months | 78794952.03 | 35944301.70 | 42850650.33 | 58988828.51 | 35953389.75 |
| Maximum of Months | 0.177343E+09 | 74576467.96 | 0.102766E+09 | 0.310716E+09 | 0.246330E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 28281808.21 | 12915963.80 | 15365844.41 | 17302108.68 | 0.100809E+09 |
| February | 31786254.99 | 17038313.14 | 14747941.85 | 28297142.68 | 74542072.66 |
| March | 44516708.42 | 20273992.56 | 24242715.87 | 46865925.00 | 53198153.45 |
| April | 52029480.59 | 23749715.58 | 28279765.02 | 68461449.59 | 41586500.57 |
| May | 59046655.09 | 25001956.46 | 34044698.63 | 87406205.41 | 28559680.22 |
| June | 59095323.58 | 24781941.39 | 34313382.19 | 0.101714E+09 | 16887341.34 |
| July | 59545920.41 | 25040374.86 | 34505545.55 | 0.106739E+09 | 12513666.55 |
| August | 54426599.54 | 21547787.83 | 32878811.70 | 98778034.17 | 10455700.66 |
| September | 43148161.42 | 19025802.49 | 24122358.93 | 66451795.06 | 23763531.62 |
| October | 38240665.04 | 19920976.39 | 18319688.65 | 45708974.96 | 50069698.13 |
| November | 29449041.97 | 13303943.42 | 16145098.55 | 25851990.91 | 63142125.03 |
| December | 26456805.88 | 12068938.28 | 14387867.60 | 16929176.43 | 82546995.29 |
| Annual Sum or Average | 0.526023E+09 | 0.234670E+09 | 0.291354E+09 | 0.710506E+09 | 0.558074E+09 |
| Minimum of Months | 26456805.88 | 12068938.28 | 14387867.60 | 16929176.43 | 10455700.66 |
| Maximum of Months | 59545920.41 | 25040374.86 | 34505545.55 | 0.106739E+09 | 0.100809E+09 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 207.06 | 323.87 | 203.92 | 130.98 | 72.93 | 0.00 | 0.00 |
| February | 239.44 | 265.37 | 203.05 | 126.06 | 76.98 | 0.00 | 0.00 |
| March | 288.10 | 168.47 | 210.39 | 106.47 | 103.92 | 0.00 | 0.00 |
| April | 293.19 | 137.18 | 189.42 | 74.87 | 114.55 | 0.00 | 0.00 |
| May | 279.08 | 91.43 | 168.15 | 42.59 | 125.55 | 0.00 | 0.00 |
| June | 318.85 | 56.25 | 166.28 | 39.42 | 126.86 | 0.00 | 0.00 |
| July | 324.74 | 36.46 | 161.17 | 36.94 | 124.23 | 0.00 | 0.00 |
| August | 353.23 | 29.57 | 173.99 | 47.61 | 126.39 | 0.00 | 0.00 |
| September | 295.66 | 81.29 | 172.30 | 69.61 | 102.70 | 0.00 | 0.00 |
| October | 296.01 | 178.35 | 204.57 | 124.23 | 80.33 | 0.00 | 0.00 |
| November | 259.55 | 231.16 | 206.03 | 126.76 | 79.27 | 0.00 | 0.00 |
| December | 218.94 | 274.18 | 198.26 | 128.77 | 69.49 | 0.00 | 0.00 |
| Annual Sum or Average | 281.38 | 155.56 | 188.05 | 87.66 | 100.40 | 0.00 | 0.00 |
| Minimum of Months | 207.06 | 29.57 | 161.17 | 36.94 | 69.49 | 0.00 | 0.00 |
| Maximum of Months | 353.23 | 323.87 | 210.39 | 130.98 | 126.86 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 29.00 | 362.07 | 75.23 | 21.02 | 54.21 | 0.00 | 0.00 |
| February | 64.70 | 287.50 | 84.82 | 24.04 | 60.78 | 0.00 | 0.00 |
| March | 139.81 | 166.20 | 122.52 | 36.48 | 86.05 | 0.00 | 0.00 |
| April | 200.74 | 132.07 | 141.83 | 39.13 | 102.70 | 0.00 | 0.00 |
| May | 243.59 | 87.17 | 153.53 | 34.61 | 118.92 | 0.00 | 0.00 |
| June | 310.18 | 53.08 | 164.62 | 39.51 | 125.11 | 0.00 | 0.00 |
| July | 308.92 | 34.91 | 155.30 | 34.86 | 120.44 | 0.00 | 0.00 |
| August | 293.13 | 28.32 | 145.95 | 31.85 | 114.10 | 0.00 | 0.00 |
| September | 186.30 | 80.47 | 115.37 | 28.42 | 86.95 | 0.00 | 0.00 |
| October | 112.80 | 180.19 | 96.19 | 31.15 | 65.04 | 0.00 | 0.00 |
| November | 69.20 | 237.18 | 80.16 | 21.37 | 58.79 | 0.00 | 0.00 |
| December | 33.68 | 298.82 | 67.72 | 17.49 | 50.23 | 0.00 | 0.00 |
| Annual Sum or Average | 166.56 | 161.70 | 117.11 | 30.02 | 87.09 | 0.00 | 0.00 |
| Minimum of Months | 29.00 | 28.32 | 67.72 | 17.49 | 50.23 | 0.00 | 0.00 |
| Maximum of Months | 310.18 | 362.07 | 164.62 | 39.51 | 125.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 214.93 | 280.38 | 202.83 | 130.05 | 72.78 | 0.00 | 0.00 |
| February | 248.52 | 241.33 | 206.39 | 131.37 | 75.02 | 0.00 | 0.00 |
| March | 267.52 | 170.49 | 204.06 | 101.54 | 102.51 | 0.00 | 0.00 |
| April | 275.96 | 142.95 | 188.05 | 74.22 | 113.83 | 0.00 | 0.00 |
| May | 270.50 | 103.70 | 174.35 | 49.00 | 125.34 | 0.00 | 0.00 |
| June | 300.25 | 77.94 | 171.09 | 44.43 | 126.67 | 0.00 | 0.00 |
| July | 304.42 | 64.53 | 169.00 | 44.47 | 124.53 | 0.00 | 0.00 |
| August | 325.37 | 61.47 | 175.55 | 50.08 | 125.47 | 0.00 | 0.00 |
| September | 276.70 | 112.52 | 173.71 | 71.80 | 101.91 | 0.00 | 0.00 |
| October | 281.42 | 194.13 | 203.89 | 124.08 | 79.82 | 0.00 | 0.00 |
| November | 252.34 | 236.52 | 205.45 | 126.78 | 78.67 | 0.00 | 0.00 |
| December | 223.53 | 259.83 | 199.57 | 130.06 | 69.51 | 0.00 | 0.00 |
| Annual Sum or Average | 270.23 | 161.71 | 189.41 | 89.60 | 99.81 | 0.00 | 0.00 |
| Minimum of Months | 214.93 | 61.47 | 169.00 | 44.43 | 69.51 | 0.00 | 0.00 |
| Maximum of Months | 325.37 | 280.38 | 206.39 | 131.37 | 126.67 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.07 | 353.54 | 74.15 | 20.10 | 54.05 | 0.00 | 0.00 |
| February | 56.90 | 273.83 | 88.17 | 29.35 | 58.82 | 0.00 | 0.00 |
| March | 118.53 | 155.17 | 116.19 | 31.55 | 84.64 | 0.00 | 0.00 |
| April | 191.17 | 123.93 | 140.46 | 38.48 | 101.98 | 0.00 | 0.00 |
| May | 249.80 | 83.96 | 159.73 | 41.02 | 118.71 | 0.00 | 0.00 |
| June | 316.93 | 51.74 | 169.44 | 44.52 | 124.92 | 0.00 | 0.00 |
| July | 321.31 | 34.60 | 163.13 | 42.39 | 120.74 | 0.00 | 0.00 |
| August | 294.76 | 27.46 | 147.51 | 34.32 | 113.18 | 0.00 | 0.00 |
| September | 185.48 | 77.31 | 116.78 | 30.61 | 86.17 | 0.00 | 0.00 |
| October | 100.38 | 169.29 | 95.52 | 31.00 | 64.52 | 0.00 | 0.00 |
| November | 54.15 | 222.20 | 79.58 | 21.39 | 58.19 | 0.00 | 0.00 |
| December | 21.70 | 283.41 | 69.03 | 18.78 | 50.25 | 0.00 | 0.00 |
| Annual Sum or Average | 161.50 | 154.12 | 118.46 | 31.96 | 86.50 | 0.00 | 0.00 |
| Minimum of Months | 20.07 | 27.46 | 69.03 | 18.78 | 50.25 | 0.00 | 0.00 |
| Maximum of Months | 321.31 | 353.54 | 169.44 | 44.52 | 124.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 4.39 | 237.38 | 30.14 | 0.00 | 30.14 | 0.00 | 0.00 |
| February | 15.77 | 186.26 | 33.41 | 0.00 | 33.41 | 0.00 | 0.00 |
| March | 38.26 | 105.89 | 46.92 | 0.00 | 46.92 | 0.00 | 0.00 |
| April | 69.62 | 83.96 | 56.81 | 0.30 | 56.51 | 0.00 | 0.00 |
| May | 101.69 | 53.79 | 67.86 | 2.12 | 65.74 | 0.00 | 0.00 |
| June | 144.26 | 31.54 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
| July | 146.53 | 20.72 | 70.48 | 3.43 | 67.05 | 0.00 | 0.00 |
| August | 133.17 | 16.38 | 62.82 | 0.79 | 62.03 | 0.00 | 0.00 |
| September | 73.92 | 48.67 | 47.40 | 0.02 | 47.38 | 0.00 | 0.00 |
| October | 30.43 | 114.03 | 36.02 | 0.00 | 36.02 | 0.00 | 0.00 |
| November | 15.71 | 150.90 | 32.23 | 0.00 | 32.23 | 0.00 | 0.00 |
| December | 4.48 | 191.87 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Annual Sum or Average | 65.14 | 103.04 | 48.95 | 0.95 | 48.00 | 0.00 | 0.00 |
| Minimum of Months | 4.39 | 16.38 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Maximum of Months | 146.53 | 237.38 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 4.39 | 237.37 | 30.14 | 0.00 | 30.14 | 0.00 | 0.00 |
| February | 15.76 | 186.27 | 33.41 | 0.00 | 33.41 | 0.00 | 0.00 |
| March | 38.26 | 105.84 | 46.92 | 0.00 | 46.92 | 0.00 | 0.00 |
| April | 69.60 | 83.92 | 56.81 | 0.30 | 56.51 | 0.00 | 0.00 |
| May | 101.66 | 53.79 | 67.86 | 2.12 | 65.74 | 0.00 | 0.00 |
| June | 144.24 | 31.54 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
| July | 146.51 | 20.72 | 70.48 | 3.43 | 67.05 | 0.00 | 0.00 |
| August | 133.17 | 16.37 | 62.82 | 0.79 | 62.03 | 0.00 | 0.00 |
| September | 73.91 | 48.66 | 47.40 | 0.02 | 47.38 | 0.00 | 0.00 |
| October | 30.41 | 114.03 | 36.02 | 0.00 | 36.02 | 0.00 | 0.00 |
| November | 15.71 | 150.87 | 32.23 | 0.00 | 32.23 | 0.00 | 0.00 |
| December | 4.47 | 191.87 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Annual Sum or Average | 65.12 | 103.03 | 48.95 | 0.95 | 48.00 | 0.00 | 0.00 |
| Minimum of Months | 4.39 | 16.37 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Maximum of Months | 146.51 | 237.37 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 182.58 | 196.21 | 158.83 | 109.96 | 48.87 | 0.00 | 0.00 |
| February | 193.34 | 163.17 | 151.64 | 102.02 | 49.61 | 0.00 | 0.00 |
| March | 189.44 | 106.99 | 134.79 | 70.00 | 64.79 | 0.00 | 0.00 |
| April | 164.28 | 88.42 | 104.39 | 36.03 | 68.36 | 0.00 | 0.00 |
| May | 137.75 | 57.63 | 82.47 | 10.10 | 72.37 | 0.00 | 0.00 |
| June | 152.31 | 34.14 | 76.08 | 4.58 | 71.50 | 0.00 | 0.00 |
| July | 162.01 | 21.86 | 76.35 | 5.51 | 70.84 | 0.00 | 0.00 |
| August | 193.62 | 17.31 | 90.87 | 16.55 | 74.32 | 0.00 | 0.00 |
| September | 184.30 | 49.02 | 104.33 | 41.21 | 63.12 | 0.00 | 0.00 |
| October | 216.70 | 109.60 | 144.39 | 93.08 | 51.31 | 0.00 | 0.00 |
| November | 211.76 | 142.29 | 158.10 | 105.39 | 52.71 | 0.00 | 0.00 |
| December | 194.22 | 167.36 | 158.40 | 111.28 | 47.12 | 0.00 | 0.00 |
| Annual Sum or Average | 181.80 | 95.81 | 119.90 | 58.59 | 61.31 | 0.00 | 0.00 |
| Minimum of Months | 137.75 | 17.31 | 76.08 | 4.58 | 47.12 | 0.00 | 0.00 |
| Maximum of Months | 216.70 | 196.21 | 158.83 | 111.28 | 74.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 183.05 | 194.94 | 158.83 | 109.96 | 48.87 | 0.00 | 0.00 |
| February | 193.50 | 162.56 | 151.64 | 102.02 | 49.61 | 0.00 | 0.00 |
| March | 189.03 | 107.49 | 134.79 | 70.00 | 64.79 | 0.00 | 0.00 |
| April | 163.72 | 89.14 | 104.39 | 36.03 | 68.36 | 0.00 | 0.00 |
| May | 137.19 | 58.25 | 82.47 | 10.10 | 72.37 | 0.00 | 0.00 |
| June | 151.59 | 34.76 | 76.08 | 4.58 | 71.50 | 0.00 | 0.00 |
| July | 161.10 | 22.54 | 76.35 | 5.51 | 70.84 | 0.00 | 0.00 |
| August | 192.74 | 18.04 | 90.87 | 16.55 | 74.32 | 0.00 | 0.00 |
| September | 183.70 | 49.80 | 104.33 | 41.21 | 63.12 | 0.00 | 0.00 |
| October | 216.32 | 110.30 | 144.39 | 93.08 | 51.31 | 0.00 | 0.00 |
| November | 211.51 | 142.71 | 158.10 | 105.39 | 52.71 | 0.00 | 0.00 |
| December | 194.34 | 167.00 | 158.40 | 111.28 | 47.12 | 0.00 | 0.00 |
| Annual Sum or Average | 181.43 | 96.11 | 119.90 | 58.59 | 61.31 | 0.00 | 0.00 |
| Minimum of Months | 137.19 | 18.04 | 76.08 | 4.58 | 47.12 | 0.00 | 0.00 |
| Maximum of Months | 216.32 | 194.94 | 158.83 | 111.28 | 74.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 200.14 | 336.75 | 203.92 | 130.98 | 72.93 | 0.00 | 0.00 |
| February | 230.20 | 282.79 | 203.05 | 126.06 | 76.98 | 0.00 | 0.00 |
| March | 272.24 | 190.89 | 210.39 | 106.47 | 103.92 | 0.00 | 0.00 |
| April | 277.75 | 157.08 | 189.42 | 74.87 | 114.55 | 0.00 | 0.00 |
| May | 269.94 | 100.90 | 168.15 | 42.59 | 125.55 | 0.00 | 0.00 |
| June | 315.48 | 58.25 | 166.28 | 39.42 | 126.86 | 0.00 | 0.00 |
| July | 323.21 | 36.94 | 161.17 | 36.94 | 124.23 | 0.00 | 0.00 |
| August | 352.97 | 28.75 | 173.99 | 47.61 | 126.39 | 0.00 | 0.00 |
| September | 295.43 | 79.95 | 172.30 | 69.61 | 102.70 | 0.00 | 0.00 |
| October | 295.52 | 175.44 | 204.57 | 124.23 | 80.33 | 0.00 | 0.00 |
| November | 258.41 | 230.54 | 206.03 | 126.76 | 79.27 | 0.00 | 0.00 |
| December | 214.41 | 281.12 | 198.26 | 128.77 | 69.49 | 0.00 | 0.00 |
| Annual Sum or Average | 275.72 | 162.65 | 188.05 | 87.66 | 100.40 | 0.00 | 0.00 |
| Minimum of Months | 200.14 | 28.75 | 161.17 | 36.94 | 69.49 | 0.00 | 0.00 |
| Maximum of Months | 352.97 | 336.75 | 210.39 | 130.98 | 126.86 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 26.43 | 377.32 | 75.23 | 21.02 | 54.21 | 0.00 | 0.00 |
| February | 59.37 | 306.05 | 84.82 | 24.04 | 60.78 | 0.00 | 0.00 |
| March | 125.62 | 190.21 | 122.52 | 36.48 | 86.05 | 0.00 | 0.00 |
| April | 184.38 | 154.33 | 141.83 | 39.13 | 102.70 | 0.00 | 0.00 |
| May | 233.68 | 97.16 | 153.53 | 34.61 | 118.92 | 0.00 | 0.00 |
| June | 306.74 | 54.95 | 164.62 | 39.51 | 125.11 | 0.00 | 0.00 |
| July | 307.45 | 35.38 | 155.30 | 34.86 | 120.44 | 0.00 | 0.00 |
| August | 293.05 | 27.64 | 145.95 | 31.85 | 114.10 | 0.00 | 0.00 |
| September | 186.45 | 79.48 | 115.37 | 28.42 | 86.95 | 0.00 | 0.00 |
| October | 113.25 | 177.58 | 96.19 | 31.15 | 65.04 | 0.00 | 0.00 |
| November | 69.15 | 237.73 | 80.16 | 21.37 | 58.79 | 0.00 | 0.00 |
| December | 31.88 | 307.24 | 67.72 | 17.49 | 50.23 | 0.00 | 0.00 |
| Annual Sum or Average | 162.02 | 169.73 | 117.11 | 30.02 | 87.09 | 0.00 | 0.00 |
| Minimum of Months | 26.43 | 27.64 | 67.72 | 17.49 | 50.23 | 0.00 | 0.00 |
| Maximum of Months | 307.45 | 377.32 | 164.62 | 39.51 | 125.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 196.77 | 333.47 | 202.83 | 130.05 | 72.78 | 0.00 | 0.00 |
| February | 232.79 | 279.86 | 206.39 | 131.37 | 75.02 | 0.00 | 0.00 |
| March | 255.15 | 184.96 | 204.06 | 101.54 | 102.51 | 0.00 | 0.00 |
| April | 267.92 | 149.09 | 188.05 | 74.22 | 113.83 | 0.00 | 0.00 |
| May | 273.56 | 95.04 | 174.35 | 49.00 | 125.34 | 0.00 | 0.00 |
| June | 319.70 | 54.19 | 171.09 | 44.43 | 126.67 | 0.00 | 0.00 |
| July | 334.19 | 35.17 | 169.00 | 44.47 | 124.53 | 0.00 | 0.00 |
| August | 354.00 | 27.24 | 175.55 | 50.08 | 125.47 | 0.00 | 0.00 |
| September | 295.18 | 77.31 | 173.71 | 71.80 | 101.91 | 0.00 | 0.00 |
| October | 289.33 | 170.31 | 203.89 | 124.08 | 79.82 | 0.00 | 0.00 |
| November | 253.69 | 226.28 | 205.45 | 126.78 | 78.67 | 0.00 | 0.00 |
| December | 214.38 | 277.51 | 199.57 | 130.06 | 69.51 | 0.00 | 0.00 |
| Annual Sum or Average | 274.11 | 158.57 | 189.41 | 89.60 | 99.81 | 0.00 | 0.00 |
| Minimum of Months | 196.77 | 27.24 | 169.00 | 44.43 | 69.51 | 0.00 | 0.00 |
| Maximum of Months | 354.00 | 333.47 | 206.39 | 131.37 | 126.67 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 17.80 | 368.86 | 74.15 | 20.10 | 54.05 | 0.00 | 0.00 |
| February | 51.08 | 292.05 | 88.17 | 29.35 | 58.82 | 0.00 | 0.00 |
| March | 103.46 | 178.51 | 116.19 | 31.55 | 84.64 | 0.00 | 0.00 |
| April | 173.44 | 145.32 | 140.46 | 38.48 | 101.98 | 0.00 | 0.00 |
| May | 239.32 | 93.36 | 159.73 | 41.02 | 118.71 | 0.00 | 0.00 |
| June | 313.51 | 53.44 | 169.44 | 44.52 | 124.92 | 0.00 | 0.00 |
| July | 319.82 | 35.00 | 163.13 | 42.39 | 120.74 | 0.00 | 0.00 |
| August | 294.70 | 26.76 | 147.51 | 34.32 | 113.18 | 0.00 | 0.00 |
| September | 185.65 | 76.32 | 116.78 | 30.61 | 86.17 | 0.00 | 0.00 |
| October | 100.81 | 166.80 | 95.52 | 31.00 | 64.52 | 0.00 | 0.00 |
| November | 54.10 | 222.51 | 79.58 | 21.39 | 58.19 | 0.00 | 0.00 |
| December | 19.81 | 291.55 | 69.03 | 18.78 | 50.25 | 0.00 | 0.00 |
| Annual Sum or Average | 156.71 | 161.89 | 118.46 | 31.96 | 86.50 | 0.00 | 0.00 |
| Minimum of Months | 17.80 | 26.76 | 69.03 | 18.78 | 50.25 | 0.00 | 0.00 |
| Maximum of Months | 319.82 | 368.86 | 169.44 | 44.52 | 124.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 3.82 | 247.26 | 30.14 | 0.00 | 30.14 | 0.00 | 0.00 |
| February | 13.50 | 198.68 | 33.41 | 0.00 | 33.41 | 0.00 | 0.00 |
| March | 31.22 | 121.65 | 46.92 | 0.00 | 46.92 | 0.00 | 0.00 |
| April | 62.16 | 95.84 | 56.81 | 0.30 | 56.51 | 0.00 | 0.00 |
| May | 97.47 | 58.08 | 67.86 | 2.12 | 65.74 | 0.00 | 0.00 |
| June | 143.07 | 32.18 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
| July | 146.20 | 20.79 | 70.48 | 3.43 | 67.05 | 0.00 | 0.00 |
| August | 133.48 | 15.93 | 62.82 | 0.79 | 62.03 | 0.00 | 0.00 |
| September | 74.14 | 48.28 | 47.40 | 0.02 | 47.38 | 0.00 | 0.00 |
| October | 30.58 | 113.31 | 36.02 | 0.00 | 36.02 | 0.00 | 0.00 |
| November | 15.58 | 152.13 | 32.23 | 0.00 | 32.23 | 0.00 | 0.00 |
| December | 3.83 | 197.84 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Annual Sum or Average | 63.21 | 108.05 | 48.95 | 0.95 | 48.00 | 0.00 | 0.00 |
| Minimum of Months | 3.82 | 15.93 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Maximum of Months | 146.20 | 247.26 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 3.82 | 247.25 | 30.14 | 0.00 | 30.14 | 0.00 | 0.00 |
| February | 13.48 | 198.69 | 33.41 | 0.00 | 33.41 | 0.00 | 0.00 |
| March | 31.19 | 121.61 | 46.92 | 0.00 | 46.92 | 0.00 | 0.00 |
| April | 62.12 | 95.84 | 56.81 | 0.30 | 56.51 | 0.00 | 0.00 |
| May | 97.45 | 58.07 | 67.86 | 2.12 | 65.74 | 0.00 | 0.00 |
| June | 143.06 | 32.18 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
| July | 146.19 | 20.78 | 70.48 | 3.43 | 67.05 | 0.00 | 0.00 |
| August | 133.47 | 15.93 | 62.82 | 0.79 | 62.03 | 0.00 | 0.00 |
| September | 74.13 | 48.27 | 47.40 | 0.02 | 47.38 | 0.00 | 0.00 |
| October | 30.55 | 113.31 | 36.02 | 0.00 | 36.02 | 0.00 | 0.00 |
| November | 15.57 | 152.09 | 32.23 | 0.00 | 32.23 | 0.00 | 0.00 |
| December | 3.83 | 197.83 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Annual Sum or Average | 63.19 | 108.04 | 48.95 | 0.95 | 48.00 | 0.00 | 0.00 |
| Minimum of Months | 3.82 | 15.93 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Maximum of Months | 146.19 | 247.25 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 177.94 | 203.96 | 158.83 | 109.96 | 48.87 | 0.00 | 0.00 |
| February | 187.44 | 174.16 | 151.64 | 102.02 | 49.61 | 0.00 | 0.00 |
| March | 180.90 | 119.73 | 134.79 | 70.00 | 64.79 | 0.00 | 0.00 |
| April | 157.39 | 98.20 | 104.39 | 36.03 | 68.36 | 0.00 | 0.00 |
| May | 134.04 | 61.59 | 82.47 | 10.10 | 72.37 | 0.00 | 0.00 |
| June | 151.18 | 34.82 | 76.08 | 4.58 | 71.50 | 0.00 | 0.00 |
| July | 161.65 | 21.88 | 76.35 | 5.51 | 70.84 | 0.00 | 0.00 |
| August | 193.72 | 16.73 | 90.87 | 16.55 | 74.32 | 0.00 | 0.00 |
| September | 184.11 | 48.35 | 104.33 | 41.21 | 63.12 | 0.00 | 0.00 |
| October | 215.97 | 108.68 | 144.39 | 93.08 | 51.31 | 0.00 | 0.00 |
| November | 210.39 | 142.82 | 158.10 | 105.39 | 52.71 | 0.00 | 0.00 |
| December | 190.89 | 172.09 | 158.40 | 111.28 | 47.12 | 0.00 | 0.00 |
| Annual Sum or Average | 178.76 | 99.85 | 119.90 | 58.59 | 61.31 | 0.00 | 0.00 |
| Minimum of Months | 134.04 | 16.73 | 76.08 | 4.58 | 47.12 | 0.00 | 0.00 |
| Maximum of Months | 215.97 | 203.96 | 158.83 | 111.28 | 74.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 177.93 | 203.95 | 158.83 | 109.96 | 48.87 | 0.00 | 0.00 |
| February | 187.41 | 174.16 | 151.64 | 102.02 | 49.61 | 0.00 | 0.00 |
| March | 180.86 | 119.71 | 134.79 | 70.00 | 64.79 | 0.00 | 0.00 |
| April | 157.35 | 98.19 | 104.39 | 36.03 | 68.36 | 0.00 | 0.00 |
| May | 134.02 | 61.58 | 82.47 | 10.10 | 72.37 | 0.00 | 0.00 |
| June | 151.17 | 34.82 | 76.08 | 4.58 | 71.50 | 0.00 | 0.00 |
| July | 161.64 | 21.88 | 76.35 | 5.51 | 70.84 | 0.00 | 0.00 |
| August | 193.72 | 16.73 | 90.87 | 16.55 | 74.32 | 0.00 | 0.00 |
| September | 184.10 | 48.34 | 104.33 | 41.21 | 63.12 | 0.00 | 0.00 |
| October | 215.96 | 108.65 | 144.39 | 93.08 | 51.31 | 0.00 | 0.00 |
| November | 210.37 | 142.81 | 158.10 | 105.39 | 52.71 | 0.00 | 0.00 |
| December | 190.87 | 172.09 | 158.40 | 111.28 | 47.12 | 0.00 | 0.00 |
| Annual Sum or Average | 178.74 | 99.85 | 119.90 | 58.59 | 61.31 | 0.00 | 0.00 |
| Minimum of Months | 134.02 | 16.73 | 76.08 | 4.58 | 47.12 | 0.00 | 0.00 |
| Maximum of Months | 215.96 | 203.95 | 158.83 | 111.28 | 74.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 200.10 | 322.91 | 203.92 | 130.98 | 72.93 | 0.00 | 0.00 |
| February | 230.60 | 267.52 | 203.05 | 126.06 | 76.98 | 0.00 | 0.00 |
| March | 274.16 | 172.83 | 210.39 | 106.47 | 103.92 | 0.00 | 0.00 |
| April | 278.71 | 141.37 | 189.42 | 74.87 | 114.55 | 0.00 | 0.00 |
| May | 266.95 | 93.23 | 168.15 | 42.59 | 125.55 | 0.00 | 0.00 |
| June | 308.73 | 55.47 | 166.28 | 39.42 | 126.86 | 0.00 | 0.00 |
| July | 315.41 | 35.76 | 161.17 | 36.94 | 124.23 | 0.00 | 0.00 |
| August | 344.88 | 27.90 | 173.99 | 47.61 | 126.39 | 0.00 | 0.00 |
| September | 292.14 | 74.01 | 172.30 | 69.61 | 102.70 | 0.00 | 0.00 |
| October | 297.99 | 155.80 | 204.57 | 124.23 | 80.33 | 0.00 | 0.00 |
| November | 262.00 | 210.16 | 206.03 | 126.76 | 79.27 | 0.00 | 0.00 |
| December | 215.35 | 265.57 | 198.26 | 128.77 | 69.49 | 0.00 | 0.00 |
| Annual Sum or Average | 274.15 | 151.27 | 188.05 | 87.66 | 100.40 | 0.00 | 0.00 |
| Minimum of Months | 200.10 | 27.90 | 161.17 | 36.94 | 69.49 | 0.00 | 0.00 |
| Maximum of Months | 344.88 | 322.91 | 210.39 | 130.98 | 126.86 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 26.88 | 363.24 | 75.23 | 21.02 | 54.21 | 0.00 | 0.00 |
| February | 59.69 | 292.37 | 84.82 | 24.04 | 60.78 | 0.00 | 0.00 |
| March | 127.30 | 174.96 | 122.52 | 36.48 | 86.05 | 0.00 | 0.00 |
| April | 186.35 | 139.10 | 141.83 | 39.13 | 102.70 | 0.00 | 0.00 |
| May | 231.56 | 89.90 | 153.53 | 34.61 | 118.92 | 0.00 | 0.00 |
| June | 300.45 | 52.72 | 164.62 | 39.51 | 125.11 | 0.00 | 0.00 |
| July | 300.01 | 34.45 | 155.30 | 34.86 | 120.44 | 0.00 | 0.00 |
| August | 285.67 | 26.99 | 145.95 | 31.85 | 114.10 | 0.00 | 0.00 |
| September | 184.42 | 73.16 | 115.37 | 28.42 | 86.95 | 0.00 | 0.00 |
| October | 116.70 | 157.30 | 96.19 | 31.15 | 65.04 | 0.00 | 0.00 |
| November | 71.39 | 221.35 | 80.16 | 21.37 | 58.79 | 0.00 | 0.00 |
| December | 32.78 | 293.00 | 67.72 | 17.49 | 50.23 | 0.00 | 0.00 |
| Annual Sum or Average | 160.82 | 159.21 | 117.11 | 30.02 | 87.09 | 0.00 | 0.00 |
| Minimum of Months | 26.88 | 26.99 | 67.72 | 17.49 | 50.23 | 0.00 | 0.00 |
| Maximum of Months | 300.45 | 363.24 | 164.62 | 39.51 | 125.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 196.98 | 319.60 | 202.83 | 130.05 | 72.78 | 0.00 | 0.00 |
| February | 233.41 | 264.67 | 206.39 | 131.37 | 75.02 | 0.00 | 0.00 |
| March | 257.76 | 167.34 | 204.06 | 101.54 | 102.51 | 0.00 | 0.00 |
| April | 270.01 | 134.64 | 188.05 | 74.22 | 113.83 | 0.00 | 0.00 |
| May | 271.07 | 88.40 | 174.35 | 49.00 | 125.34 | 0.00 | 0.00 |
| June | 313.18 | 51.97 | 171.09 | 44.43 | 126.67 | 0.00 | 0.00 |
| July | 326.28 | 34.07 | 169.00 | 44.47 | 124.53 | 0.00 | 0.00 |
| August | 345.82 | 26.39 | 175.55 | 50.08 | 125.47 | 0.00 | 0.00 |
| September | 291.98 | 71.65 | 173.71 | 71.80 | 101.91 | 0.00 | 0.00 |
| October | 291.99 | 151.51 | 203.89 | 124.08 | 79.82 | 0.00 | 0.00 |
| November | 257.47 | 205.99 | 205.45 | 126.78 | 78.67 | 0.00 | 0.00 |
| December | 215.56 | 262.00 | 199.57 | 130.06 | 69.51 | 0.00 | 0.00 |
| Annual Sum or Average | 272.83 | 147.58 | 189.41 | 89.60 | 99.81 | 0.00 | 0.00 |
| Minimum of Months | 196.98 | 26.39 | 169.00 | 44.43 | 69.51 | 0.00 | 0.00 |
| Maximum of Months | 345.82 | 319.60 | 206.39 | 131.37 | 126.67 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 18.76 | 355.10 | 74.15 | 20.10 | 54.05 | 0.00 | 0.00 |
| February | 52.43 | 279.14 | 88.17 | 29.35 | 58.82 | 0.00 | 0.00 |
| March | 106.72 | 164.24 | 116.19 | 31.55 | 84.64 | 0.00 | 0.00 |
| April | 176.61 | 131.39 | 140.46 | 38.48 | 101.98 | 0.00 | 0.00 |
| May | 237.40 | 86.83 | 159.73 | 41.02 | 118.71 | 0.00 | 0.00 |
| June | 307.07 | 51.36 | 169.44 | 44.52 | 124.92 | 0.00 | 0.00 |
| July | 312.12 | 34.00 | 163.13 | 42.39 | 120.74 | 0.00 | 0.00 |
| August | 287.14 | 26.04 | 147.51 | 34.32 | 113.18 | 0.00 | 0.00 |
| September | 183.77 | 70.44 | 116.78 | 30.61 | 86.17 | 0.00 | 0.00 |
| October | 106.46 | 148.53 | 95.52 | 31.00 | 64.52 | 0.00 | 0.00 |
| November | 57.74 | 206.98 | 79.58 | 21.39 | 58.19 | 0.00 | 0.00 |
| December | 21.54 | 277.93 | 69.03 | 18.78 | 50.25 | 0.00 | 0.00 |
| Annual Sum or Average | 156.21 | 152.04 | 118.46 | 31.96 | 86.50 | 0.00 | 0.00 |
| Minimum of Months | 18.76 | 26.04 | 69.03 | 18.78 | 50.25 | 0.00 | 0.00 |
| Maximum of Months | 312.12 | 355.10 | 169.44 | 44.52 | 124.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 3.99 | 238.35 | 30.14 | 0.00 | 30.14 | 0.00 | 0.00 |
| February | 14.23 | 189.08 | 33.41 | 0.00 | 33.41 | 0.00 | 0.00 |
| March | 33.53 | 110.45 | 46.92 | 0.00 | 46.92 | 0.00 | 0.00 |
| April | 63.95 | 86.80 | 56.81 | 0.30 | 56.51 | 0.00 | 0.00 |
| May | 96.54 | 54.75 | 67.86 | 2.12 | 65.74 | 0.00 | 0.00 |
| June | 139.92 | 31.40 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
| July | 142.35 | 20.58 | 70.48 | 3.43 | 67.05 | 0.00 | 0.00 |
| August | 129.71 | 15.81 | 62.82 | 0.79 | 62.03 | 0.00 | 0.00 |
| September | 73.22 | 45.28 | 47.40 | 0.02 | 47.38 | 0.00 | 0.00 |
| October | 33.47 | 98.99 | 36.02 | 0.00 | 36.02 | 0.00 | 0.00 |
| November | 17.82 | 139.83 | 32.23 | 0.00 | 32.23 | 0.00 | 0.00 |
| December | 4.37 | 188.21 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Annual Sum or Average | 63.04 | 101.19 | 48.95 | 0.95 | 48.00 | 0.00 | 0.00 |
| Minimum of Months | 3.99 | 15.81 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Maximum of Months | 142.35 | 238.35 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 3.98 | 238.34 | 30.14 | 0.00 | 30.14 | 0.00 | 0.00 |
| February | 14.18 | 189.06 | 33.41 | 0.00 | 33.41 | 0.00 | 0.00 |
| March | 33.45 | 110.34 | 46.92 | 0.00 | 46.92 | 0.00 | 0.00 |
| April | 63.85 | 86.73 | 56.81 | 0.30 | 56.51 | 0.00 | 0.00 |
| May | 96.47 | 54.72 | 67.86 | 2.12 | 65.74 | 0.00 | 0.00 |
| June | 139.87 | 31.38 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
| July | 142.32 | 20.56 | 70.48 | 3.43 | 67.05 | 0.00 | 0.00 |
| August | 129.70 | 15.80 | 62.82 | 0.79 | 62.03 | 0.00 | 0.00 |
| September | 73.18 | 45.25 | 47.40 | 0.02 | 47.38 | 0.00 | 0.00 |
| October | 33.37 | 98.94 | 36.02 | 0.00 | 36.02 | 0.00 | 0.00 |
| November | 17.78 | 139.74 | 32.23 | 0.00 | 32.23 | 0.00 | 0.00 |
| December | 4.36 | 188.20 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Annual Sum or Average | 62.99 | 101.15 | 48.95 | 0.95 | 48.00 | 0.00 | 0.00 |
| Minimum of Months | 3.98 | 15.80 | 27.87 | 0.00 | 27.87 | 0.00 | 0.00 |
| Maximum of Months | 142.32 | 238.34 | 74.42 | 4.68 | 69.75 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 178.61 | 195.15 | 158.83 | 109.96 | 48.87 | 0.00 | 0.00 |
| February | 188.79 | 163.67 | 151.64 | 102.02 | 49.61 | 0.00 | 0.00 |
| March | 183.65 | 107.48 | 134.79 | 70.00 | 64.79 | 0.00 | 0.00 |
| April | 158.62 | 89.33 | 104.39 | 36.03 | 68.36 | 0.00 | 0.00 |
| May | 132.54 | 58.05 | 82.47 | 10.10 | 72.37 | 0.00 | 0.00 |
| June | 147.78 | 33.72 | 76.08 | 4.58 | 71.50 | 0.00 | 0.00 |
| July | 157.58 | 21.53 | 76.35 | 5.51 | 70.84 | 0.00 | 0.00 |
| August | 189.48 | 16.48 | 90.87 | 16.55 | 74.32 | 0.00 | 0.00 |
| September | 182.37 | 45.63 | 104.33 | 41.21 | 63.12 | 0.00 | 0.00 |
| October | 218.13 | 96.31 | 144.39 | 93.08 | 51.31 | 0.00 | 0.00 |
| November | 214.12 | 128.68 | 158.10 | 105.39 | 52.71 | 0.00 | 0.00 |
| December | 192.43 | 161.40 | 158.40 | 111.28 | 47.12 | 0.00 | 0.00 |
| Annual Sum or Average | 178.62 | 92.74 | 119.90 | 58.59 | 61.31 | 0.00 | 0.00 |
| Minimum of Months | 132.54 | 16.48 | 76.08 | 4.58 | 47.12 | 0.00 | 0.00 |
| Maximum of Months | 218.13 | 195.15 | 158.83 | 111.28 | 74.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 178.57 | 195.11 | 158.83 | 109.96 | 48.87 | 0.00 | 0.00 |
| February | 188.72 | 163.65 | 151.64 | 102.02 | 49.61 | 0.00 | 0.00 |
| March | 183.55 | 107.40 | 134.79 | 70.00 | 64.79 | 0.00 | 0.00 |
| April | 158.52 | 89.26 | 104.39 | 36.03 | 68.36 | 0.00 | 0.00 |
| May | 132.47 | 58.02 | 82.47 | 10.10 | 72.37 | 0.00 | 0.00 |
| June | 147.73 | 33.69 | 76.08 | 4.58 | 71.50 | 0.00 | 0.00 |
| July | 157.55 | 21.52 | 76.35 | 5.51 | 70.84 | 0.00 | 0.00 |
| August | 189.46 | 16.47 | 90.87 | 16.55 | 74.32 | 0.00 | 0.00 |
| September | 182.34 | 45.60 | 104.33 | 41.21 | 63.12 | 0.00 | 0.00 |
| October | 218.05 | 96.26 | 144.39 | 93.08 | 51.31 | 0.00 | 0.00 |
| November | 214.05 | 128.63 | 158.10 | 105.39 | 52.71 | 0.00 | 0.00 |
| December | 192.38 | 161.36 | 158.40 | 111.28 | 47.12 | 0.00 | 0.00 |
| Annual Sum or Average | 178.57 | 92.71 | 119.90 | 58.59 | 61.31 | 0.00 | 0.00 |
| Minimum of Months | 132.47 | 16.47 | 76.08 | 4.58 | 47.12 | 0.00 | 0.00 |
| Maximum of Months | 218.05 | 195.11 | 158.83 | 111.28 | 74.32 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 7.00 | 34.32 | 10.56 | 4.82 | 5.74 | 0.00 | 0.00 |
| February | 12.47 | 28.02 | 13.14 | 7.04 | 6.10 | 0.00 | 0.00 |
| March | 18.69 | 17.71 | 16.62 | 7.57 | 9.05 | 0.00 | 0.00 |
| April | 27.54 | 14.56 | 20.07 | 9.16 | 10.91 | 0.00 | 0.00 |
| May | 33.04 | 10.08 | 22.05 | 9.33 | 12.71 | 0.00 | 0.00 |
| June | 39.00 | 6.37 | 22.80 | 9.56 | 13.24 | 0.00 | 0.00 |
| July | 39.33 | 4.65 | 22.23 | 9.35 | 12.88 | 0.00 | 0.00 |
| August | 36.33 | 3.92 | 20.32 | 8.05 | 12.28 | 0.00 | 0.00 |
| September | 25.83 | 8.59 | 16.65 | 7.34 | 9.31 | 0.00 | 0.00 |
| October | 18.24 | 16.41 | 14.28 | 7.44 | 6.84 | 0.00 | 0.00 |
| November | 11.12 | 21.64 | 11.36 | 5.13 | 6.23 | 0.00 | 0.00 |
| December | 7.03 | 27.76 | 9.88 | 4.51 | 5.37 | 0.00 | 0.00 |
| Annual Sum or Average | 23.02 | 16.11 | 16.68 | 7.44 | 9.24 | 0.00 | 0.00 |
| Minimum of Months | 7.00 | 3.92 | 9.88 | 4.51 | 5.37 | 0.00 | 0.00 |
| Maximum of Months | 39.33 | 34.32 | 22.80 | 9.56 | 13.24 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 22.75 | 91.97 | 31.45 | 14.36 | 17.09 | 0.00 | 0.00 |
| February | 39.54 | 75.38 | 39.13 | 20.98 | 18.16 | 0.00 | 0.00 |
| March | 58.82 | 48.31 | 49.50 | 22.54 | 26.96 | 0.00 | 0.00 |
| April | 84.76 | 40.49 | 59.78 | 27.29 | 32.49 | 0.00 | 0.00 |
| May | 100.42 | 28.84 | 65.66 | 27.80 | 37.86 | 0.00 | 0.00 |
| June | 115.73 | 19.86 | 67.90 | 28.47 | 39.43 | 0.00 | 0.00 |
| July | 116.01 | 15.05 | 66.21 | 27.84 | 38.37 | 0.00 | 0.00 |
| August | 106.75 | 13.42 | 60.52 | 23.96 | 36.56 | 0.00 | 0.00 |
| September | 75.63 | 27.86 | 49.58 | 21.86 | 27.72 | 0.00 | 0.00 |
| October | 52.34 | 52.74 | 42.52 | 22.15 | 20.37 | 0.00 | 0.00 |
| November | 32.43 | 66.36 | 33.84 | 15.29 | 18.55 | 0.00 | 0.00 |
| December | 22.02 | 78.90 | 29.42 | 13.42 | 16.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.08 | 46.45 | 49.68 | 22.16 | 27.52 | 0.00 | 0.00 |
| Minimum of Months | 22.02 | 13.42 | 29.42 | 13.42 | 16.00 | 0.00 | 0.00 |
| Maximum of Months | 116.01 | 91.97 | 67.90 | 28.47 | 39.43 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 6.46 | 37.64 | 10.56 | 4.82 | 5.74 | 0.00 | 0.00 |
| February | 11.70 | 30.81 | 13.14 | 7.04 | 6.10 | 0.00 | 0.00 |
| March | 17.50 | 19.86 | 16.62 | 7.57 | 9.05 | 0.00 | 0.00 |
| April | 26.41 | 16.04 | 20.07 | 9.16 | 10.91 | 0.00 | 0.00 |
| May | 32.63 | 10.66 | 22.05 | 9.33 | 12.71 | 0.00 | 0.00 |
| June | 39.24 | 6.52 | 22.80 | 9.56 | 13.24 | 0.00 | 0.00 |
| July | 39.85 | 4.67 | 22.23 | 9.35 | 12.88 | 0.00 | 0.00 |
| August | 36.88 | 3.90 | 20.32 | 8.05 | 12.28 | 0.00 | 0.00 |
| September | 25.64 | 9.17 | 16.65 | 7.34 | 9.31 | 0.00 | 0.00 |
| October | 17.07 | 18.69 | 14.28 | 7.44 | 6.84 | 0.00 | 0.00 |
| November | 9.97 | 24.36 | 11.36 | 5.13 | 6.23 | 0.00 | 0.00 |
| December | 6.32 | 30.82 | 9.88 | 4.51 | 5.37 | 0.00 | 0.00 |
| Annual Sum or Average | 22.53 | 17.70 | 16.68 | 7.44 | 9.24 | 0.00 | 0.00 |
| Minimum of Months | 6.32 | 3.90 | 9.88 | 4.51 | 5.37 | 0.00 | 0.00 |
| Maximum of Months | 39.85 | 37.64 | 22.80 | 9.56 | 13.24 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.554577E+09 | 0.867442E+09 | 0.546169E+09 | 0.350822E+09 | 0.195347E+09 | 0.00 | 0.00 |
| February | 0.579253E+09 | 0.641992E+09 | 0.491210E+09 | 0.304969E+09 | 0.186241E+09 | 0.00 | 0.00 |
| March | 0.771658E+09 | 0.451242E+09 | 0.563514E+09 | 0.285175E+09 | 0.278339E+09 | 0.00 | 0.00 |
| April | 0.759950E+09 | 0.355571E+09 | 0.490971E+09 | 0.194052E+09 | 0.296918E+09 | 0.00 | 0.00 |
| May | 0.747488E+09 | 0.244886E+09 | 0.450364E+09 | 0.114077E+09 | 0.336286E+09 | 0.00 | 0.00 |
| June | 0.826446E+09 | 0.145802E+09 | 0.430996E+09 | 0.102168E+09 | 0.328828E+09 | 0.00 | 0.00 |
| July | 0.869794E+09 | 97660293.50 | 0.431680E+09 | 98930857.14 | 0.332749E+09 | 0.00 | 0.00 |
| August | 0.946104E+09 | 79208655.38 | 0.466022E+09 | 0.127510E+09 | 0.338512E+09 | 0.00 | 0.00 |
| September | 0.766341E+09 | 0.210703E+09 | 0.446613E+09 | 0.180422E+09 | 0.266191E+09 | 0.00 | 0.00 |
| October | 0.792837E+09 | 0.477685E+09 | 0.547910E+09 | 0.332744E+09 | 0.215166E+09 | 0.00 | 0.00 |
| November | 0.672761E+09 | 0.599169E+09 | 0.534017E+09 | 0.328551E+09 | 0.205466E+09 | 0.00 | 0.00 |
| December | 0.586398E+09 | 0.734369E+09 | 0.531008E+09 | 0.344893E+09 | 0.186115E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.887361E+10 | 0.490573E+10 | 0.593047E+10 | 0.276432E+10 | 0.316616E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.554577E+09 | 79208655.38 | 0.430996E+09 | 98930857.14 | 0.186115E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.946104E+09 | 0.867442E+09 | 0.563514E+09 | 0.350822E+09 | 0.338512E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 77685646.33 | 0.969770E+09 | 0.201507E+09 | 56313031.91 | 0.145194E+09 | 0.00 | 0.00 |
| February | 0.156523E+09 | 0.695508E+09 | 0.205201E+09 | 58154304.47 | 0.147047E+09 | 0.00 | 0.00 |
| March | 0.374471E+09 | 0.445158E+09 | 0.328167E+09 | 97701219.40 | 0.230466E+09 | 0.00 | 0.00 |
| April | 0.520331E+09 | 0.342334E+09 | 0.367625E+09 | 0.101430E+09 | 0.266195E+09 | 0.00 | 0.00 |
| May | 0.652443E+09 | 0.233473E+09 | 0.411223E+09 | 92696533.44 | 0.318527E+09 | 0.00 | 0.00 |
| June | 0.803977E+09 | 0.137572E+09 | 0.426708E+09 | 0.102420E+09 | 0.324288E+09 | 0.00 | 0.00 |
| July | 0.827423E+09 | 93493542.68 | 0.415954E+09 | 93358637.44 | 0.322596E+09 | 0.00 | 0.00 |
| August | 0.785110E+09 | 75846833.07 | 0.390901E+09 | 85305621.19 | 0.305595E+09 | 0.00 | 0.00 |
| September | 0.482881E+09 | 0.208580E+09 | 0.299042E+09 | 73656709.08 | 0.225385E+09 | 0.00 | 0.00 |
| October | 0.302111E+09 | 0.482612E+09 | 0.257634E+09 | 83434328.24 | 0.174200E+09 | 0.00 | 0.00 |
| November | 0.179360E+09 | 0.614782E+09 | 0.207765E+09 | 55388735.27 | 0.152377E+09 | 0.00 | 0.00 |
| December | 90212143.20 | 0.800368E+09 | 0.181382E+09 | 46844477.73 | 0.134538E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.525253E+10 | 0.509950E+10 | 0.369311E+10 | 0.946703E+09 | 0.274641E+10 | 0.00 | 0.00 |
| Minimum of Months | 77685646.33 | 75846833.07 | 0.181382E+09 | 46844477.73 | 0.134538E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.827423E+09 | 0.969770E+09 | 0.426708E+09 | 0.102420E+09 | 0.324288E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.575667E+09 | 0.750964E+09 | 0.543261E+09 | 0.348336E+09 | 0.194926E+09 | 0.00 | 0.00 |
| February | 0.601213E+09 | 0.583822E+09 | 0.499306E+09 | 0.317822E+09 | 0.181484E+09 | 0.00 | 0.00 |
| March | 0.716525E+09 | 0.456629E+09 | 0.546541E+09 | 0.271972E+09 | 0.274569E+09 | 0.00 | 0.00 |
| April | 0.715301E+09 | 0.370519E+09 | 0.487420E+09 | 0.192368E+09 | 0.295052E+09 | 0.00 | 0.00 |
| May | 0.724511E+09 | 0.277740E+09 | 0.466968E+09 | 0.131247E+09 | 0.335721E+09 | 0.00 | 0.00 |
| June | 0.778253E+09 | 0.202033E+09 | 0.443470E+09 | 0.115150E+09 | 0.328320E+09 | 0.00 | 0.00 |
| July | 0.815370E+09 | 0.172842E+09 | 0.452650E+09 | 0.119119E+09 | 0.333531E+09 | 0.00 | 0.00 |
| August | 0.871465E+09 | 0.164651E+09 | 0.470203E+09 | 0.134132E+09 | 0.336071E+09 | 0.00 | 0.00 |
| September | 0.717208E+09 | 0.291654E+09 | 0.450252E+09 | 0.186104E+09 | 0.264148E+09 | 0.00 | 0.00 |
| October | 0.753749E+09 | 0.519958E+09 | 0.546107E+09 | 0.332330E+09 | 0.213777E+09 | 0.00 | 0.00 |
| November | 0.654071E+09 | 0.613055E+09 | 0.532527E+09 | 0.328606E+09 | 0.203921E+09 | 0.00 | 0.00 |
| December | 0.598692E+09 | 0.695925E+09 | 0.534519E+09 | 0.348346E+09 | 0.186173E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.852203E+10 | 0.509979E+10 | 0.597322E+10 | 0.282553E+10 | 0.314769E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.575667E+09 | 0.164651E+09 | 0.443470E+09 | 0.115150E+09 | 0.181484E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.871465E+09 | 0.750964E+09 | 0.546541E+09 | 0.348346E+09 | 0.336071E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 53755741.58 | 0.946912E+09 | 0.198600E+09 | 53826816.83 | 0.144773E+09 | 0.00 | 0.00 |
| February | 0.137651E+09 | 0.662439E+09 | 0.213296E+09 | 71006560.18 | 0.142290E+09 | 0.00 | 0.00 |
| March | 0.317480E+09 | 0.415604E+09 | 0.311194E+09 | 84497834.44 | 0.226697E+09 | 0.00 | 0.00 |
| April | 0.495503E+09 | 0.321229E+09 | 0.364075E+09 | 99746099.60 | 0.264329E+09 | 0.00 | 0.00 |
| May | 0.669074E+09 | 0.224875E+09 | 0.427828E+09 | 0.109866E+09 | 0.317961E+09 | 0.00 | 0.00 |
| June | 0.821485E+09 | 0.134117E+09 | 0.439182E+09 | 0.115402E+09 | 0.323780E+09 | 0.00 | 0.00 |
| July | 0.860588E+09 | 92664166.57 | 0.436925E+09 | 0.113547E+09 | 0.323378E+09 | 0.00 | 0.00 |
| August | 0.789491E+09 | 73550256.04 | 0.395081E+09 | 91927284.19 | 0.303154E+09 | 0.00 | 0.00 |
| September | 0.480764E+09 | 0.200390E+09 | 0.302682E+09 | 79339350.87 | 0.223342E+09 | 0.00 | 0.00 |
| October | 0.268850E+09 | 0.453429E+09 | 0.255831E+09 | 83019956.12 | 0.172811E+09 | 0.00 | 0.00 |
| November | 0.140357E+09 | 0.575953E+09 | 0.206275E+09 | 55443708.03 | 0.150832E+09 | 0.00 | 0.00 |
| December | 58122968.97 | 0.759073E+09 | 0.184893E+09 | 50296868.29 | 0.134596E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.509312E+10 | 0.486024E+10 | 0.373586E+10 | 0.100792E+10 | 0.272794E+10 | 0.00 | 0.00 |
| Minimum of Months | 53755741.58 | 73550256.04 | 0.184893E+09 | 50296868.29 | 0.134596E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.860588E+09 | 0.946912E+09 | 0.439182E+09 | 0.115402E+09 | 0.323780E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 11770603.17 | 0.635786E+09 | 80736292.62 | 0.00 | 80736292.62 | 0.00 | 0.00 |
| February | 38151475.09 | 0.450612E+09 | 80828105.99 | 0.00 | 80828105.99 | 0.00 | 0.00 |
| March | 0.102472E+09 | 0.283624E+09 | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.00 | 0.00 |
| April | 0.180451E+09 | 0.217629E+09 | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.00 | 0.00 |
| May | 0.272360E+09 | 0.144067E+09 | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.00 | 0.00 |
| June | 0.373916E+09 | 81764403.93 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
| July | 0.392464E+09 | 55501382.57 | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.00 | 0.00 |
| August | 0.356694E+09 | 43859517.72 | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.00 | 0.00 |
| September | 0.191594E+09 | 0.126147E+09 | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.00 | 0.00 |
| October | 81512122.32 | 0.305417E+09 | 96464614.35 | 0.00 | 96464614.35 | 0.00 | 0.00 |
| November | 40729277.31 | 0.391131E+09 | 83547509.06 | 0.00 | 83547509.06 | 0.00 | 0.00 |
| December | 11986810.72 | 0.513898E+09 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Annual Sum or Average | 0.205410E+10 | 0.324944E+10 | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.00 | 0.00 |
| Minimum of Months | 11770603.17 | 43859517.72 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Maximum of Months | 0.392464E+09 | 0.635786E+09 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 11765606.67 | 0.635776E+09 | 80736292.62 | 0.00 | 80736292.62 | 0.00 | 0.00 |
| February | 38114540.17 | 0.450629E+09 | 80828105.99 | 0.00 | 80828105.99 | 0.00 | 0.00 |
| March | 0.102464E+09 | 0.283490E+09 | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.00 | 0.00 |
| April | 0.180398E+09 | 0.217522E+09 | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.00 | 0.00 |
| May | 0.272283E+09 | 0.144065E+09 | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.00 | 0.00 |
| June | 0.373865E+09 | 81759943.52 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
| July | 0.392419E+09 | 55501944.49 | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.00 | 0.00 |
| August | 0.356672E+09 | 43844942.14 | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.00 | 0.00 |
| September | 0.191566E+09 | 0.126133E+09 | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.00 | 0.00 |
| October | 81446529.68 | 0.305417E+09 | 96464614.35 | 0.00 | 96464614.35 | 0.00 | 0.00 |
| November | 40709154.11 | 0.391057E+09 | 83547509.06 | 0.00 | 83547509.06 | 0.00 | 0.00 |
| December | 11980551.18 | 0.513898E+09 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Annual Sum or Average | 0.205368E+10 | 0.324910E+10 | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.00 | 0.00 |
| Minimum of Months | 11765606.67 | 43844942.14 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Maximum of Months | 0.392419E+09 | 0.635776E+09 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.489031E+09 | 0.525523E+09 | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.00 | 0.00 |
| February | 0.467731E+09 | 0.394748E+09 | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.00 | 0.00 |
| March | 0.507396E+09 | 0.286551E+09 | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.00 | 0.00 |
| April | 0.425821E+09 | 0.229182E+09 | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.00 | 0.00 |
| May | 0.368937E+09 | 0.154366E+09 | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.00 | 0.00 |
| June | 0.394792E+09 | 88495123.63 | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.00 | 0.00 |
| July | 0.433922E+09 | 58559847.26 | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.00 | 0.00 |
| August | 0.518589E+09 | 46359765.56 | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.00 | 0.00 |
| September | 0.477694E+09 | 0.127072E+09 | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.00 | 0.00 |
| October | 0.580402E+09 | 0.293542E+09 | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.00 | 0.00 |
| November | 0.548872E+09 | 0.368812E+09 | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.00 | 0.00 |
| December | 0.520191E+09 | 0.448261E+09 | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.573338E+10 | 0.302147E+10 | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.368937E+09 | 46359765.56 | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.580402E+09 | 0.525523E+09 | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.490282E+09 | 0.522136E+09 | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.00 | 0.00 |
| February | 0.468120E+09 | 0.393275E+09 | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.00 | 0.00 |
| March | 0.506295E+09 | 0.287914E+09 | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.00 | 0.00 |
| April | 0.424361E+09 | 0.231047E+09 | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.00 | 0.00 |
| May | 0.367456E+09 | 0.156014E+09 | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.00 | 0.00 |
| June | 0.392931E+09 | 90108706.93 | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.00 | 0.00 |
| July | 0.431500E+09 | 60381429.87 | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.00 | 0.00 |
| August | 0.516234E+09 | 48305649.41 | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.00 | 0.00 |
| September | 0.476159E+09 | 0.129089E+09 | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.00 | 0.00 |
| October | 0.579392E+09 | 0.295424E+09 | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.00 | 0.00 |
| November | 0.548239E+09 | 0.369911E+09 | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.00 | 0.00 |
| December | 0.520511E+09 | 0.447302E+09 | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.572148E+10 | 0.303091E+10 | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.367456E+09 | 48305649.41 | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.579392E+09 | 0.522136E+09 | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.536045E+09 | 0.901952E+09 | 0.546169E+09 | 0.350822E+09 | 0.195347E+09 | 0.00 | 0.00 |
| February | 0.556889E+09 | 0.684124E+09 | 0.491210E+09 | 0.304969E+09 | 0.186241E+09 | 0.00 | 0.00 |
| March | 0.729179E+09 | 0.511279E+09 | 0.563514E+09 | 0.285175E+09 | 0.278339E+09 | 0.00 | 0.00 |
| April | 0.719928E+09 | 0.407142E+09 | 0.490971E+09 | 0.194052E+09 | 0.296918E+09 | 0.00 | 0.00 |
| May | 0.723020E+09 | 0.270256E+09 | 0.450364E+09 | 0.114077E+09 | 0.336286E+09 | 0.00 | 0.00 |
| June | 0.817713E+09 | 0.150992E+09 | 0.430996E+09 | 0.102168E+09 | 0.328828E+09 | 0.00 | 0.00 |
| July | 0.865676E+09 | 98929139.95 | 0.431680E+09 | 98930857.14 | 0.332749E+09 | 0.00 | 0.00 |
| August | 0.945388E+09 | 76998993.59 | 0.466022E+09 | 0.127510E+09 | 0.338512E+09 | 0.00 | 0.00 |
| September | 0.765752E+09 | 0.207236E+09 | 0.446613E+09 | 0.180422E+09 | 0.266191E+09 | 0.00 | 0.00 |
| October | 0.791513E+09 | 0.469891E+09 | 0.547910E+09 | 0.332744E+09 | 0.215166E+09 | 0.00 | 0.00 |
| November | 0.669797E+09 | 0.597562E+09 | 0.534017E+09 | 0.328551E+09 | 0.205466E+09 | 0.00 | 0.00 |
| December | 0.574289E+09 | 0.752952E+09 | 0.531008E+09 | 0.344893E+09 | 0.186115E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.869519E+10 | 0.512931E+10 | 0.593047E+10 | 0.276432E+10 | 0.316616E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.536045E+09 | 76998993.59 | 0.430996E+09 | 98930857.14 | 0.186115E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.945388E+09 | 0.901952E+09 | 0.563514E+09 | 0.350822E+09 | 0.338512E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 70790680.35 | 0.101060E+10 | 0.201507E+09 | 56313031.91 | 0.145194E+09 | 0.00 | 0.00 |
| February | 0.143639E+09 | 0.740406E+09 | 0.205201E+09 | 58154304.47 | 0.147047E+09 | 0.00 | 0.00 |
| March | 0.336449E+09 | 0.509446E+09 | 0.328167E+09 | 97701219.40 | 0.230466E+09 | 0.00 | 0.00 |
| April | 0.477908E+09 | 0.400016E+09 | 0.367625E+09 | 0.101430E+09 | 0.266195E+09 | 0.00 | 0.00 |
| May | 0.625885E+09 | 0.260242E+09 | 0.411223E+09 | 92696533.44 | 0.318527E+09 | 0.00 | 0.00 |
| June | 0.795060E+09 | 0.142433E+09 | 0.426708E+09 | 0.102420E+09 | 0.324288E+09 | 0.00 | 0.00 |
| July | 0.823480E+09 | 94749899.02 | 0.415954E+09 | 93358637.44 | 0.322596E+09 | 0.00 | 0.00 |
| August | 0.784903E+09 | 74038923.07 | 0.390901E+09 | 85305621.19 | 0.305595E+09 | 0.00 | 0.00 |
| September | 0.483289E+09 | 0.206020E+09 | 0.299042E+09 | 73656709.08 | 0.225385E+09 | 0.00 | 0.00 |
| October | 0.303338E+09 | 0.475623E+09 | 0.257634E+09 | 83434328.24 | 0.174200E+09 | 0.00 | 0.00 |
| November | 0.179245E+09 | 0.616204E+09 | 0.207765E+09 | 55388735.27 | 0.152377E+09 | 0.00 | 0.00 |
| December | 85381172.28 | 0.822912E+09 | 0.181382E+09 | 46844477.73 | 0.134538E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.510937E+10 | 0.535269E+10 | 0.369311E+10 | 0.946703E+09 | 0.274641E+10 | 0.00 | 0.00 |
| Minimum of Months | 70790680.35 | 74038923.07 | 0.181382E+09 | 46844477.73 | 0.134538E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.823480E+09 | 0.101060E+10 | 0.426708E+09 | 0.102420E+09 | 0.324288E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.527015E+09 | 0.893170E+09 | 0.543261E+09 | 0.348336E+09 | 0.194926E+09 | 0.00 | 0.00 |
| February | 0.563155E+09 | 0.677043E+09 | 0.499306E+09 | 0.317822E+09 | 0.181484E+09 | 0.00 | 0.00 |
| March | 0.683388E+09 | 0.495409E+09 | 0.546541E+09 | 0.271972E+09 | 0.274569E+09 | 0.00 | 0.00 |
| April | 0.694453E+09 | 0.386443E+09 | 0.487420E+09 | 0.192368E+09 | 0.295052E+09 | 0.00 | 0.00 |
| May | 0.732716E+09 | 0.254565E+09 | 0.466968E+09 | 0.131247E+09 | 0.335721E+09 | 0.00 | 0.00 |
| June | 0.828656E+09 | 0.140467E+09 | 0.443470E+09 | 0.115150E+09 | 0.328320E+09 | 0.00 | 0.00 |
| July | 0.895089E+09 | 94207448.98 | 0.452650E+09 | 0.119119E+09 | 0.333531E+09 | 0.00 | 0.00 |
| August | 0.948142E+09 | 72947381.09 | 0.470203E+09 | 0.134132E+09 | 0.336071E+09 | 0.00 | 0.00 |
| September | 0.765118E+09 | 0.200387E+09 | 0.450252E+09 | 0.186104E+09 | 0.264148E+09 | 0.00 | 0.00 |
| October | 0.774943E+09 | 0.456153E+09 | 0.546107E+09 | 0.332330E+09 | 0.213777E+09 | 0.00 | 0.00 |
| November | 0.657560E+09 | 0.586519E+09 | 0.532527E+09 | 0.328606E+09 | 0.203921E+09 | 0.00 | 0.00 |
| December | 0.574187E+09 | 0.743282E+09 | 0.534519E+09 | 0.348346E+09 | 0.186173E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.864442E+10 | 0.500059E+10 | 0.597322E+10 | 0.282553E+10 | 0.314769E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.527015E+09 | 72947381.09 | 0.443470E+09 | 0.115150E+09 | 0.181484E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.948142E+09 | 0.893170E+09 | 0.546541E+09 | 0.348346E+09 | 0.336071E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 47670848.77 | 0.987959E+09 | 0.198600E+09 | 53826816.83 | 0.144773E+09 | 0.00 | 0.00 |
| February | 0.123564E+09 | 0.706525E+09 | 0.213296E+09 | 71006560.18 | 0.142290E+09 | 0.00 | 0.00 |
| March | 0.277117E+09 | 0.478133E+09 | 0.311194E+09 | 84497834.44 | 0.226697E+09 | 0.00 | 0.00 |
| April | 0.449555E+09 | 0.376669E+09 | 0.364075E+09 | 99746099.60 | 0.264329E+09 | 0.00 | 0.00 |
| May | 0.640998E+09 | 0.250046E+09 | 0.427828E+09 | 0.109866E+09 | 0.317961E+09 | 0.00 | 0.00 |
| June | 0.812630E+09 | 0.138515E+09 | 0.439182E+09 | 0.115402E+09 | 0.323780E+09 | 0.00 | 0.00 |
| July | 0.856593E+09 | 93749125.33 | 0.436925E+09 | 0.113547E+09 | 0.323378E+09 | 0.00 | 0.00 |
| August | 0.789321E+09 | 71670108.05 | 0.395081E+09 | 91927284.19 | 0.303154E+09 | 0.00 | 0.00 |
| September | 0.481194E+09 | 0.197829E+09 | 0.302682E+09 | 79339350.87 | 0.223342E+09 | 0.00 | 0.00 |
| October | 0.270018E+09 | 0.446751E+09 | 0.255831E+09 | 83019956.12 | 0.172811E+09 | 0.00 | 0.00 |
| November | 0.140232E+09 | 0.576738E+09 | 0.206275E+09 | 55443708.03 | 0.150832E+09 | 0.00 | 0.00 |
| December | 53065971.88 | 0.780876E+09 | 0.184893E+09 | 50296868.29 | 0.134596E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.494196E+10 | 0.510546E+10 | 0.373586E+10 | 0.100792E+10 | 0.272794E+10 | 0.00 | 0.00 |
| Minimum of Months | 47670848.77 | 71670108.05 | 0.184893E+09 | 50296868.29 | 0.134596E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.856593E+09 | 0.987959E+09 | 0.439182E+09 | 0.115402E+09 | 0.323780E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 10236281.52 | 0.662259E+09 | 80736292.62 | 0.00 | 80736292.62 | 0.00 | 0.00 |
| February | 32664190.65 | 0.480639E+09 | 80828105.99 | 0.00 | 80828105.99 | 0.00 | 0.00 |
| March | 83610672.25 | 0.325829E+09 | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.00 | 0.00 |
| April | 0.161131E+09 | 0.248428E+09 | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.00 | 0.00 |
| May | 0.261056E+09 | 0.155549E+09 | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.00 | 0.00 |
| June | 0.370844E+09 | 83423088.73 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
| July | 0.391587E+09 | 55676832.37 | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.00 | 0.00 |
| August | 0.357503E+09 | 42676123.90 | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.00 | 0.00 |
| September | 0.192178E+09 | 0.125139E+09 | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.00 | 0.00 |
| October | 81907480.19 | 0.303489E+09 | 96464614.35 | 0.00 | 96464614.35 | 0.00 | 0.00 |
| November | 40392981.00 | 0.394319E+09 | 83547509.06 | 0.00 | 83547509.06 | 0.00 | 0.00 |
| December | 10271192.53 | 0.529886E+09 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Annual Sum or Average | 0.199338E+10 | 0.340731E+10 | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.00 | 0.00 |
| Minimum of Months | 10236281.52 | 42676123.90 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Maximum of Months | 0.391587E+09 | 0.662259E+09 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 10229156.48 | 0.662247E+09 | 80736292.62 | 0.00 | 80736292.62 | 0.00 | 0.00 |
| February | 32603978.07 | 0.480676E+09 | 80828105.99 | 0.00 | 80828105.99 | 0.00 | 0.00 |
| March | 83537494.56 | 0.325724E+09 | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.00 | 0.00 |
| April | 0.161023E+09 | 0.248421E+09 | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.00 | 0.00 |
| May | 0.261001E+09 | 0.155533E+09 | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.00 | 0.00 |
| June | 0.370802E+09 | 83410065.49 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
| July | 0.391550E+09 | 55669618.78 | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.00 | 0.00 |
| August | 0.357481E+09 | 42659026.00 | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.00 | 0.00 |
| September | 0.192147E+09 | 0.125120E+09 | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.00 | 0.00 |
| October | 81812166.29 | 0.303500E+09 | 96464614.35 | 0.00 | 96464614.35 | 0.00 | 0.00 |
| November | 40367229.24 | 0.394219E+09 | 83547509.06 | 0.00 | 83547509.06 | 0.00 | 0.00 |
| December | 10264033.16 | 0.529881E+09 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Annual Sum or Average | 0.199282E+10 | 0.340706E+10 | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.00 | 0.00 |
| Minimum of Months | 10229156.48 | 42659026.00 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Maximum of Months | 0.391550E+09 | 0.662247E+09 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.476602E+09 | 0.546286E+09 | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.00 | 0.00 |
| February | 0.453459E+09 | 0.421318E+09 | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.00 | 0.00 |
| March | 0.484514E+09 | 0.320676E+09 | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.00 | 0.00 |
| April | 0.407943E+09 | 0.254534E+09 | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.00 | 0.00 |
| May | 0.359004E+09 | 0.164959E+09 | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.00 | 0.00 |
| June | 0.391871E+09 | 90262311.28 | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.00 | 0.00 |
| July | 0.432960E+09 | 58614845.74 | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.00 | 0.00 |
| August | 0.518873E+09 | 44821505.69 | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.00 | 0.00 |
| September | 0.477221E+09 | 0.125321E+09 | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.00 | 0.00 |
| October | 0.578465E+09 | 0.291077E+09 | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.00 | 0.00 |
| November | 0.545336E+09 | 0.370188E+09 | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.00 | 0.00 |
| December | 0.511279E+09 | 0.460936E+09 | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.563753E+10 | 0.314899E+10 | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.359004E+09 | 44821505.69 | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.578465E+09 | 0.546286E+09 | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.476559E+09 | 0.546252E+09 | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.00 | 0.00 |
| February | 0.453373E+09 | 0.421336E+09 | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.00 | 0.00 |
| March | 0.484419E+09 | 0.320623E+09 | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.00 | 0.00 |
| April | 0.407850E+09 | 0.254518E+09 | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.00 | 0.00 |
| May | 0.358953E+09 | 0.164941E+09 | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.00 | 0.00 |
| June | 0.391829E+09 | 90249877.56 | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.00 | 0.00 |
| July | 0.432924E+09 | 58607543.13 | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.00 | 0.00 |
| August | 0.518852E+09 | 44804189.23 | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.00 | 0.00 |
| September | 0.477196E+09 | 0.125303E+09 | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.00 | 0.00 |
| October | 0.578426E+09 | 0.291019E+09 | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.00 | 0.00 |
| November | 0.545272E+09 | 0.370175E+09 | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.00 | 0.00 |
| December | 0.511219E+09 | 0.460925E+09 | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.563687E+10 | 0.314875E+10 | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.358953E+09 | 44804189.23 | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.578426E+09 | 0.546252E+09 | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.535935E+09 | 0.864872E+09 | 0.546169E+09 | 0.350822E+09 | 0.195347E+09 | 0.00 | 0.00 |
| February | 0.557860E+09 | 0.647181E+09 | 0.491210E+09 | 0.304969E+09 | 0.186241E+09 | 0.00 | 0.00 |
| March | 0.734319E+09 | 0.462915E+09 | 0.563514E+09 | 0.285175E+09 | 0.278339E+09 | 0.00 | 0.00 |
| April | 0.722414E+09 | 0.366432E+09 | 0.490971E+09 | 0.194052E+09 | 0.296918E+09 | 0.00 | 0.00 |
| May | 0.714992E+09 | 0.249704E+09 | 0.450364E+09 | 0.114077E+09 | 0.336286E+09 | 0.00 | 0.00 |
| June | 0.800217E+09 | 0.143778E+09 | 0.430996E+09 | 0.102168E+09 | 0.328828E+09 | 0.00 | 0.00 |
| July | 0.844785E+09 | 95781037.81 | 0.431680E+09 | 98930857.14 | 0.332749E+09 | 0.00 | 0.00 |
| August | 0.923717E+09 | 74720457.05 | 0.466022E+09 | 0.127510E+09 | 0.338512E+09 | 0.00 | 0.00 |
| September | 0.757233E+09 | 0.191825E+09 | 0.446613E+09 | 0.180422E+09 | 0.266191E+09 | 0.00 | 0.00 |
| October | 0.798136E+09 | 0.417304E+09 | 0.547910E+09 | 0.332744E+09 | 0.215166E+09 | 0.00 | 0.00 |
| November | 0.679096E+09 | 0.544730E+09 | 0.534017E+09 | 0.328551E+09 | 0.205466E+09 | 0.00 | 0.00 |
| December | 0.576781E+09 | 0.711312E+09 | 0.531008E+09 | 0.344893E+09 | 0.186115E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.864548E+10 | 0.477056E+10 | 0.593047E+10 | 0.276432E+10 | 0.316616E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.535935E+09 | 74720457.05 | 0.430996E+09 | 98930857.14 | 0.186115E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.923717E+09 | 0.864872E+09 | 0.563514E+09 | 0.350822E+09 | 0.338512E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 72006012.09 | 0.972889E+09 | 0.201507E+09 | 56313031.91 | 0.145194E+09 | 0.00 | 0.00 |
| February | 0.144410E+09 | 0.707290E+09 | 0.205201E+09 | 58154304.47 | 0.147047E+09 | 0.00 | 0.00 |
| March | 0.340959E+09 | 0.468605E+09 | 0.328167E+09 | 97701219.40 | 0.230466E+09 | 0.00 | 0.00 |
| April | 0.483013E+09 | 0.360535E+09 | 0.367625E+09 | 0.101430E+09 | 0.266195E+09 | 0.00 | 0.00 |
| May | 0.620221E+09 | 0.240786E+09 | 0.411223E+09 | 92696533.44 | 0.318527E+09 | 0.00 | 0.00 |
| June | 0.778757E+09 | 0.136662E+09 | 0.426708E+09 | 0.102420E+09 | 0.324288E+09 | 0.00 | 0.00 |
| July | 0.803536E+09 | 92261798.60 | 0.415954E+09 | 93358637.44 | 0.322596E+09 | 0.00 | 0.00 |
| August | 0.765126E+09 | 72299295.10 | 0.390901E+09 | 85305621.19 | 0.305595E+09 | 0.00 | 0.00 |
| September | 0.478004E+09 | 0.189625E+09 | 0.299042E+09 | 73656709.08 | 0.225385E+09 | 0.00 | 0.00 |
| October | 0.312582E+09 | 0.421299E+09 | 0.257634E+09 | 83434328.24 | 0.174200E+09 | 0.00 | 0.00 |
| November | 0.185048E+09 | 0.573735E+09 | 0.207765E+09 | 55388735.27 | 0.152377E+09 | 0.00 | 0.00 |
| December | 87808026.25 | 0.784758E+09 | 0.181382E+09 | 46844477.73 | 0.134538E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.507147E+10 | 0.502075E+10 | 0.369311E+10 | 0.946703E+09 | 0.274641E+10 | 0.00 | 0.00 |
| Minimum of Months | 72006012.09 | 72299295.10 | 0.181382E+09 | 46844477.73 | 0.134538E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.803536E+09 | 0.972889E+09 | 0.426708E+09 | 0.102420E+09 | 0.324288E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.527589E+09 | 0.856009E+09 | 0.543261E+09 | 0.348336E+09 | 0.194926E+09 | 0.00 | 0.00 |
| February | 0.564665E+09 | 0.640298E+09 | 0.499306E+09 | 0.317822E+09 | 0.181484E+09 | 0.00 | 0.00 |
| March | 0.690387E+09 | 0.448197E+09 | 0.546541E+09 | 0.271972E+09 | 0.274569E+09 | 0.00 | 0.00 |
| April | 0.699856E+09 | 0.348992E+09 | 0.487420E+09 | 0.192368E+09 | 0.295052E+09 | 0.00 | 0.00 |
| May | 0.726031E+09 | 0.236776E+09 | 0.466968E+09 | 0.131247E+09 | 0.335721E+09 | 0.00 | 0.00 |
| June | 0.811769E+09 | 0.134693E+09 | 0.443470E+09 | 0.115150E+09 | 0.328320E+09 | 0.00 | 0.00 |
| July | 0.873897E+09 | 91251919.04 | 0.452650E+09 | 0.119119E+09 | 0.333531E+09 | 0.00 | 0.00 |
| August | 0.926232E+09 | 70690490.17 | 0.470203E+09 | 0.134132E+09 | 0.336071E+09 | 0.00 | 0.00 |
| September | 0.756800E+09 | 0.185711E+09 | 0.450252E+09 | 0.186104E+09 | 0.264148E+09 | 0.00 | 0.00 |
| October | 0.782061E+09 | 0.405795E+09 | 0.546107E+09 | 0.332330E+09 | 0.213777E+09 | 0.00 | 0.00 |
| November | 0.667357E+09 | 0.533919E+09 | 0.532527E+09 | 0.328606E+09 | 0.203921E+09 | 0.00 | 0.00 |
| December | 0.577362E+09 | 0.701728E+09 | 0.534519E+09 | 0.348346E+09 | 0.186173E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.860400E+10 | 0.465406E+10 | 0.597322E+10 | 0.282553E+10 | 0.314769E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.527589E+09 | 70690490.17 | 0.443470E+09 | 0.115150E+09 | 0.181484E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.926232E+09 | 0.856009E+09 | 0.546541E+09 | 0.348346E+09 | 0.336071E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 50250001.12 | 0.951096E+09 | 0.198600E+09 | 53826816.83 | 0.144773E+09 | 0.00 | 0.00 |
| February | 0.126850E+09 | 0.675305E+09 | 0.213296E+09 | 71006560.18 | 0.142290E+09 | 0.00 | 0.00 |
| March | 0.285826E+09 | 0.439889E+09 | 0.311194E+09 | 84497834.44 | 0.226697E+09 | 0.00 | 0.00 |
| April | 0.457779E+09 | 0.340558E+09 | 0.364075E+09 | 99746099.60 | 0.264329E+09 | 0.00 | 0.00 |
| May | 0.635842E+09 | 0.232560E+09 | 0.427828E+09 | 0.109866E+09 | 0.317961E+09 | 0.00 | 0.00 |
| June | 0.795922E+09 | 0.133128E+09 | 0.439182E+09 | 0.115402E+09 | 0.323780E+09 | 0.00 | 0.00 |
| July | 0.835976E+09 | 91065541.23 | 0.436925E+09 | 0.113547E+09 | 0.323378E+09 | 0.00 | 0.00 |
| August | 0.769079E+09 | 69745178.09 | 0.395081E+09 | 91927284.19 | 0.303154E+09 | 0.00 | 0.00 |
| September | 0.476334E+09 | 0.182590E+09 | 0.302682E+09 | 79339350.87 | 0.223342E+09 | 0.00 | 0.00 |
| October | 0.285131E+09 | 0.397821E+09 | 0.255831E+09 | 83019956.12 | 0.172811E+09 | 0.00 | 0.00 |
| November | 0.149660E+09 | 0.536504E+09 | 0.206275E+09 | 55443708.03 | 0.150832E+09 | 0.00 | 0.00 |
| December | 57683622.21 | 0.744416E+09 | 0.184893E+09 | 50296868.29 | 0.134596E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.492633E+10 | 0.479468E+10 | 0.373586E+10 | 0.100792E+10 | 0.272794E+10 | 0.00 | 0.00 |
| Minimum of Months | 50250001.12 | 69745178.09 | 0.184893E+09 | 50296868.29 | 0.134596E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.835976E+09 | 0.951096E+09 | 0.439182E+09 | 0.115402E+09 | 0.323780E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 10689248.10 | 0.638385E+09 | 80736292.62 | 0.00 | 80736292.62 | 0.00 | 0.00 |
| February | 34418390.88 | 0.457418E+09 | 80828105.99 | 0.00 | 80828105.99 | 0.00 | 0.00 |
| March | 89806600.35 | 0.295835E+09 | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.00 | 0.00 |
| April | 0.165763E+09 | 0.224991E+09 | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.00 | 0.00 |
| May | 0.258569E+09 | 0.146647E+09 | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.00 | 0.00 |
| June | 0.362663E+09 | 81398022.38 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
| July | 0.381268E+09 | 55111344.81 | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.00 | 0.00 |
| August | 0.347426E+09 | 42355721.05 | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.00 | 0.00 |
| September | 0.189794E+09 | 0.117358E+09 | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.00 | 0.00 |
| October | 89632674.98 | 0.265142E+09 | 96464614.35 | 0.00 | 96464614.35 | 0.00 | 0.00 |
| November | 46191832.73 | 0.362447E+09 | 83547509.06 | 0.00 | 83547509.06 | 0.00 | 0.00 |
| December | 11699347.31 | 0.504106E+09 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Annual Sum or Average | 0.198792E+10 | 0.319119E+10 | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.00 | 0.00 |
| Minimum of Months | 10689248.10 | 42355721.05 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Maximum of Months | 0.381268E+09 | 0.638385E+09 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 10673111.02 | 0.638358E+09 | 80736292.62 | 0.00 | 80736292.62 | 0.00 | 0.00 |
| February | 34313560.08 | 0.457374E+09 | 80828105.99 | 0.00 | 80828105.99 | 0.00 | 0.00 |
| March | 89600871.53 | 0.295528E+09 | 0.125673E+09 | 6696.11 | 0.125666E+09 | 0.00 | 0.00 |
| April | 0.165492E+09 | 0.224797E+09 | 0.147244E+09 | 770009.96 | 0.146474E+09 | 0.00 | 0.00 |
| May | 0.258387E+09 | 0.146558E+09 | 0.181753E+09 | 5671696.28 | 0.176081E+09 | 0.00 | 0.00 |
| June | 0.362542E+09 | 81345948.73 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
| July | 0.381196E+09 | 55076677.96 | 0.188769E+09 | 9192347.44 | 0.179577E+09 | 0.00 | 0.00 |
| August | 0.347377E+09 | 42312211.53 | 0.168260E+09 | 2127649.63 | 0.166133E+09 | 0.00 | 0.00 |
| September | 0.189687E+09 | 0.117286E+09 | 0.122863E+09 | 49999.95 | 0.122813E+09 | 0.00 | 0.00 |
| October | 89367590.92 | 0.265009E+09 | 96464614.35 | 0.00 | 96464614.35 | 0.00 | 0.00 |
| November | 46097544.46 | 0.362216E+09 | 83547509.06 | 0.00 | 83547509.06 | 0.00 | 0.00 |
| December | 11674645.94 | 0.504069E+09 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Annual Sum or Average | 0.198641E+10 | 0.318993E+10 | 0.154368E+10 | 29942432.46 | 0.151374E+10 | 0.00 | 0.00 |
| Minimum of Months | 10673111.02 | 42312211.53 | 74634708.72 | 0.00 | 74634708.72 | 0.00 | 0.00 |
| Maximum of Months | 0.381196E+09 | 0.638358E+09 | 0.192905E+09 | 12124033.09 | 0.180781E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.478387E+09 | 0.522688E+09 | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.00 | 0.00 |
| February | 0.456730E+09 | 0.395954E+09 | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.00 | 0.00 |
| March | 0.491891E+09 | 0.287879E+09 | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.00 | 0.00 |
| April | 0.411139E+09 | 0.231552E+09 | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.00 | 0.00 |
| May | 0.354984E+09 | 0.155486E+09 | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.00 | 0.00 |
| June | 0.383036E+09 | 87389472.06 | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.00 | 0.00 |
| July | 0.422063E+09 | 57663093.55 | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.00 | 0.00 |
| August | 0.507505E+09 | 44145566.97 | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.00 | 0.00 |
| September | 0.472712E+09 | 0.118264E+09 | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.00 | 0.00 |
| October | 0.584228E+09 | 0.257947E+09 | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.00 | 0.00 |
| November | 0.554996E+09 | 0.333546E+09 | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.00 | 0.00 |
| December | 0.515401E+09 | 0.432289E+09 | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.563307E+10 | 0.292480E+10 | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.354984E+09 | 44145566.97 | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.584228E+09 | 0.522688E+09 | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.478277E+09 | 0.522582E+09 | 0.425398E+09 | 0.294509E+09 | 0.130889E+09 | 0.00 | 0.00 |
| February | 0.456558E+09 | 0.395894E+09 | 0.366837E+09 | 0.246815E+09 | 0.120022E+09 | 0.00 | 0.00 |
| March | 0.491628E+09 | 0.287669E+09 | 0.361019E+09 | 0.187481E+09 | 0.173539E+09 | 0.00 | 0.00 |
| April | 0.410888E+09 | 0.231357E+09 | 0.270589E+09 | 93392172.06 | 0.177197E+09 | 0.00 | 0.00 |
| May | 0.354811E+09 | 0.155392E+09 | 0.220893E+09 | 27052476.98 | 0.193841E+09 | 0.00 | 0.00 |
| June | 0.382915E+09 | 87336351.16 | 0.197193E+09 | 11872485.42 | 0.185320E+09 | 0.00 | 0.00 |
| July | 0.421991E+09 | 57628271.86 | 0.204495E+09 | 14764567.15 | 0.189730E+09 | 0.00 | 0.00 |
| August | 0.507460E+09 | 44101903.18 | 0.243382E+09 | 44332195.87 | 0.199050E+09 | 0.00 | 0.00 |
| September | 0.472628E+09 | 0.118195E+09 | 0.270434E+09 | 0.106815E+09 | 0.163619E+09 | 0.00 | 0.00 |
| October | 0.584020E+09 | 0.257830E+09 | 0.386740E+09 | 0.249310E+09 | 0.137430E+09 | 0.00 | 0.00 |
| November | 0.554828E+09 | 0.333419E+09 | 0.409799E+09 | 0.273163E+09 | 0.136637E+09 | 0.00 | 0.00 |
| December | 0.515262E+09 | 0.432191E+09 | 0.424261E+09 | 0.298049E+09 | 0.126212E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.563127E+10 | 0.292360E+10 | 0.378104E+10 | 0.184756E+10 | 0.193349E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.354811E+09 | 44101903.18 | 0.197193E+09 | 11872485.42 | 0.120022E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.584020E+09 | 0.522582E+09 | 0.425398E+09 | 0.298049E+09 | 0.199050E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 18742165.08 | 91909737.13 | 28281808.21 | 12915963.80 | 15365844.41 | 0.00 | 0.00 |
| February | 30166779.84 | 67785517.75 | 31786254.99 | 17038313.14 | 14747941.85 | 0.00 | 0.00 |
| March | 50072464.66 | 47423853.37 | 44516708.42 | 20273992.56 | 24242715.87 | 0.00 | 0.00 |
| April | 71396166.29 | 37738480.40 | 52029480.59 | 23749715.58 | 28279765.02 | 0.00 | 0.00 |
| May | 88482797.22 | 27007667.90 | 59046655.09 | 25001956.46 | 34044698.63 | 0.00 | 0.00 |
| June | 0.101097E+09 | 16520706.21 | 59095323.58 | 24781941.39 | 34313382.19 | 0.00 | 0.00 |
| July | 0.105353E+09 | 12453138.16 | 59545920.41 | 25040374.86 | 34505545.55 | 0.00 | 0.00 |
| August | 97311383.53 | 10488552.20 | 54426599.54 | 21547787.83 | 32878811.70 | 0.00 | 0.00 |
| September | 66940833.25 | 22260954.50 | 43148161.42 | 19025802.49 | 24122358.93 | 0.00 | 0.00 |
| October | 48866819.33 | 43953404.90 | 38240665.04 | 19920976.39 | 18319688.65 | 0.00 | 0.00 |
| November | 28828759.83 | 56091228.05 | 29449041.97 | 13303943.42 | 16145098.55 | 0.00 | 0.00 |
| December | 18838314.54 | 74363332.00 | 26456805.88 | 12068938.28 | 14387867.60 | 0.00 | 0.00 |
| Annual Sum or Average | 0.726096E+09 | 0.507997E+09 | 0.526023E+09 | 0.234670E+09 | 0.291354E+09 | 0.00 | 0.00 |
| Minimum of Months | 18742165.08 | 10488552.20 | 26456805.88 | 12068938.28 | 14387867.60 | 0.00 | 0.00 |
| Maximum of Months | 0.105353E+09 | 91909737.13 | 59545920.41 | 25040374.86 | 34505545.55 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 60923654.99 | 0.246330E+09 | 84230263.14 | 38466954.49 | 45763308.65 | 0.00 | 0.00 |
| February | 95643736.49 | 0.182366E+09 | 94667377.79 | 50744336.74 | 43923041.05 | 0.00 | 0.00 |
| March | 0.157544E+09 | 0.129384E+09 | 0.132582E+09 | 60380995.28 | 72200840.98 | 0.00 | 0.00 |
| April | 0.219697E+09 | 0.104955E+09 | 0.154957E+09 | 70732563.43 | 84224178.01 | 0.00 | 0.00 |
| May | 0.268958E+09 | 77236389.44 | 0.175856E+09 | 74462048.41 | 0.101394E+09 | 0.00 | 0.00 |
| June | 0.299966E+09 | 51487601.77 | 0.176001E+09 | 73806788.78 | 0.102194E+09 | 0.00 | 0.00 |
| July | 0.310716E+09 | 40309030.38 | 0.177343E+09 | 74576467.96 | 0.102766E+09 | 0.00 | 0.00 |
| August | 0.285923E+09 | 35953389.75 | 0.162096E+09 | 64174674.62 | 97921283.58 | 0.00 | 0.00 |
| September | 0.196031E+09 | 72204608.61 | 0.128506E+09 | 56663574.65 | 71842388.06 | 0.00 | 0.00 |
| October | 0.140201E+09 | 0.141270E+09 | 0.113890E+09 | 59329625.30 | 54560591.90 | 0.00 | 0.00 |
| November | 84050077.21 | 0.172013E+09 | 87706575.77 | 39622454.37 | 48084121.41 | 0.00 | 0.00 |
| December | 58988828.51 | 0.211324E+09 | 78794952.03 | 35944301.70 | 42850650.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.217864E+10 | 0.146483E+10 | 0.156663E+10 | 0.698905E+09 | 0.867724E+09 | 0.00 | 0.00 |
| Minimum of Months | 58988828.51 | 35953389.75 | 78794952.03 | 35944301.70 | 42850650.33 | 0.00 | 0.00 |
| Maximum of Months | 0.310716E+09 | 0.246330E+09 | 0.177343E+09 | 74576467.96 | 0.102766E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 17302108.68 | 0.100809E+09 | 28281808.21 | 12915963.80 | 15365844.41 | 0.00 | 0.00 |
| February | 28297142.68 | 74542072.66 | 31786254.99 | 17038313.14 | 14747941.85 | 0.00 | 0.00 |
| March | 46865925.00 | 53198153.45 | 44516708.42 | 20273992.56 | 24242715.87 | 0.00 | 0.00 |
| April | 68461449.59 | 41586500.57 | 52029480.59 | 23749715.58 | 28279765.02 | 0.00 | 0.00 |
| May | 87406205.41 | 28559680.22 | 59046655.09 | 25001956.46 | 34044698.63 | 0.00 | 0.00 |
| June | 0.101714E+09 | 16887341.34 | 59095323.58 | 24781941.39 | 34313382.19 | 0.00 | 0.00 |
| July | 0.106739E+09 | 12513666.55 | 59545920.41 | 25040374.86 | 34505545.55 | 0.00 | 0.00 |
| August | 98778034.17 | 10455700.66 | 54426599.54 | 21547787.83 | 32878811.70 | 0.00 | 0.00 |
| September | 66451795.06 | 23763531.62 | 43148161.42 | 19025802.49 | 24122358.93 | 0.00 | 0.00 |
| October | 45708974.96 | 50069698.13 | 38240665.04 | 19920976.39 | 18319688.65 | 0.00 | 0.00 |
| November | 25851990.91 | 63142125.03 | 29449041.97 | 13303943.42 | 16145098.55 | 0.00 | 0.00 |
| December | 16929176.43 | 82546995.29 | 26456805.88 | 12068938.28 | 14387867.60 | 0.00 | 0.00 |
| Annual Sum or Average | 0.710506E+09 | 0.558074E+09 | 0.526023E+09 | 0.234670E+09 | 0.291354E+09 | 0.00 | 0.00 |
| Minimum of Months | 16929176.43 | 10455700.66 | 26456805.88 | 12068938.28 | 14387867.60 | 0.00 | 0.00 |
| Maximum of Months | 0.106739E+09 | 0.100809E+09 | 59545920.41 | 25040374.86 | 34505545.55 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 3.96 | 1.39 | -3.0 | 4.56 | -7.8 | 48.74 | 150.20 | 0.00 |
| February | 7.94 | 4.18 | -1.3 | 5.19 | -4.0 | 51.84 | 169.20 | 0.00 |
| March | 13.76 | 8.97 | 3.80 | 4.89 | 2.25 | 76.95 | 193.22 | 0.00 |
| April | 17.21 | 12.54 | 8.82 | 3.95 | 6.45 | 95.37 | 211.82 | 0.00 |
| May | 20.84 | 16.44 | 13.69 | 3.50 | 11.46 | 117.34 | 200.00 | 0.00 |
| June | 24.80 | 19.35 | 16.45 | 3.85 | 15.08 | 121.81 | 213.08 | 0.00 |
| July | 26.06 | 21.68 | 19.85 | 3.24 | 17.64 | 119.92 | 194.46 | 0.00 |
| August | 26.55 | 22.42 | 20.72 | 3.39 | 18.21 | 115.12 | 179.15 | 0.00 |
| September | 22.53 | 18.74 | 16.82 | 3.06 | 13.44 | 83.74 | 156.58 | 0.02 |
| October | 16.03 | 13.02 | 10.77 | 4.05 | 5.85 | 53.01 | 190.38 | 0.00 |
| November | 11.94 | 8.22 | 4.17 | 4.16 | 0.30 | 52.20 | 150.38 | 0.00 |
| December | 7.70 | 4.64 | 0.26 | 4.69 | -4.1 | 44.81 | 142.03 | 0.00 |
| Annual Sum or Average | 16.65 | 12.68 | 9.31 | 4.04 | 6.29 | 81.91 | 179.25 | 0.00 |
| Minimum of Months | 3.96 | 1.39 | -3.0 | 3.06 | -7.8 | 44.81 | 142.03 | 0.00 |
| Maximum of Months | 26.55 | 22.42 | 20.72 | 5.19 | 18.21 | 121.81 | 213.08 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 21.10 | 31-JAN-14:00 | 12.97 | 6.70 | 5.70 | 12.22 | 200.50 | 90.50 |
| February | 25.00 | 26-FEB-14:00 | 12.75 | 1.70 | 4.10 | 8.15 | 91.50 | 816.00 |
| March | 27.80 | 30-MAR-13:00 | 17.87 | 12.20 | 5.70 | 16.30 | 231.50 | 710.50 |
| April | 28.90 | 17-APR-14:20 | 16.56 | 8.13 | 2.03 | 13.35 | 125.83 | 887.67 |
| May | 30.60 | 19-MAY-13:00 | 18.49 | 11.70 | 4.60 | 15.76 | 140.00 | 875.50 |
| June | 34.40 | 06-JUN-14:00 | 22.39 | 17.20 | 8.20 | 22.13 | 251.00 | 561.00 |
| July | 36.70 | 08-JUL-14:00 | 23.91 | 18.90 | 2.10 | 24.66 | 274.00 | 567.00 |
| August | 35.00 | 01-AUG-14:00 | 23.84 | 19.40 | 2.60 | 26.15 | 306.00 | 508.00 |
| September | 31.70 | 07-SEP-15:09 | 23.05 | 19.60 | 4.02 | 22.55 | 218.67 | 591.33 |
| October | 30.00 | 10-OCT-15:00 | 20.56 | 16.10 | 3.60 | 17.57 | 97.00 | 561.00 |
| November | 24.40 | 05-NOV-15:00 | 17.95 | 14.40 | 2.10 | 14.10 | 117.50 | 361.50 |
| December | 22.80 | 12-DEC-14:20 | 16.78 | 13.33 | 5.20 | 13.35 | 144.17 | 433.83 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 21.10 | 12.75 | 1.70 | 2.03 | 8.15 | 91.50 | 90.50 | |
| Maximum of Months | 36.70 | 23.91 | 19.60 | 8.20 | 26.15 | 306.00 | 887.67 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -6.7 | 14-JAN-06:10 | -7.8 | -10.6 | 4.95 | -24.7 | 0.00 | 0.00 |
| February | -12.8 | 12-FEB-06:00 | -13.8 | -18.3 | 7.20 | -30.1 | 0.00 | 0.00 |
| March | 1.10 | 19-MAR-06:00 | -1.5 | -6.1 | 0.00 | -16.2 | 17.00 | 290.50 |
| April | 0.00 | 06-APR-04:00 | -1.1 | -2.8 | 3.10 | -16.5 | 0.00 | 0.00 |
| May | 7.80 | 11-MAY-05:00 | 5.45 | 2.80 | 4.10 | -7.8 | 21.50 | 204.50 |
| June | 11.10 | 10-JUN-04:00 | 8.73 | 6.70 | 0.00 | -2.5 | 0.00 | 0.00 |
| July | 17.20 | 28-JUL-22:00 | 16.88 | 16.70 | 4.10 | 14.28 | 0.00 | 0.00 |
| August | 18.30 | 25-AUG-05:00 | 17.20 | 16.70 | 3.60 | 5.13 | 0.00 | 0.00 |
| September | 11.70 | 29-SEP-03:00 | 11.07 | 10.60 | 2.60 | -2.3 | 0.00 | 0.00 |
| October | 2.20 | 26-OCT-04:00 | 1.95 | 1.70 | 3.10 | -13.4 | 0.00 | 0.00 |
| November | -3.3 | 22-NOV-05:00 | -4.0 | -5.6 | 5.20 | -20.2 | 0.00 | 0.00 |
| December | -5.6 | 18-DEC-07:00 | -7.3 | -11.7 | 2.60 | -22.7 | 17.00 | 320.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -12.8 | -13.8 | -18.3 | 0.00 | -30.1 | 0.00 | 0.00 | |
| Maximum of Months | 18.30 | 17.20 | 16.70 | 7.20 | 14.28 | 21.50 | 320.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 16.51 | 19-JAN-21:00 | 18.30 | 15.60 | 8.80 | 15.21 | 0.00 | 0.00 |
| February | 15.81 | 18-FEB-15:00 | 17.20 | 15.00 | 5.20 | 13.91 | 73.00 | 1.00 |
| March | 18.16 | 30-MAR-12:30 | 25.85 | 13.85 | 5.45 | 15.39 | 323.00 | 600.00 |
| April | 20.01 | 04-APR-13:00 | 25.00 | 17.80 | 9.30 | 18.64 | 307.00 | 197.50 |
| May | 22.34 | 30-MAY-17:00 | 27.80 | 20.00 | 4.10 | 21.96 | 97.50 | 79.50 |
| June | 24.32 | 23-JUN-11:39 | 31.13 | 21.87 | 4.83 | 22.98 | 338.17 | 565.17 |
| July | 25.06 | 07-JUL-11:00 | 33.30 | 22.20 | 3.60 | 20.75 | 116.50 | 900.00 |
| August | 25.13 | 19-AUG-16:00 | 30.00 | 23.30 | 3.10 | 23.66 | 197.00 | 136.50 |
| September | 24.10 | 09-SEP-10:00 | 30.60 | 21.70 | 2.60 | 21.27 | 236.00 | 482.00 |
| October | 23.20 | 18-OCT-15:00 | 25.60 | 22.20 | 5.70 | 23.82 | 159.00 | 2.00 |
| November | 18.88 | 19-NOV-14:00 | 24.40 | 16.10 | 8.20 | 13.91 | 143.00 | 384.50 |
| December | 17.57 | 13-DEC-10:00 | 19.40 | 16.70 | 4.60 | 14.47 | 227.50 | 77.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 15.81 | 17.20 | 13.85 | 2.60 | 13.91 | 0.00 | 0.00 | |
| Maximum of Months | 25.13 | 33.30 | 23.30 | 9.30 | 23.82 | 338.17 | 900.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 15.60 | 19-JAN-17:00 | 17.20 | 16.13 | 6.70 | 14.10 | 0.00 | 0.00 |
| February | 15.00 | 18-FEB-16:19 | 17.20 | 15.81 | 5.53 | 13.91 | 50.33 | 1.00 |
| March | 16.10 | 31-MAR-10:00 | 21.70 | 18.06 | 13.90 | 18.64 | 268.00 | 8.00 |
| April | 17.80 | 04-APR-09:20 | 20.77 | 18.74 | 7.53 | 16.79 | 242.00 | 111.50 |
| May | 20.60 | 30-MAY-19:00 | 25.00 | 21.79 | 2.60 | 12.41 | 0.00 | 0.00 |
| June | 22.80 | 18-JUN-16:00 | 28.30 | 24.23 | 0.00 | 24.66 | 140.50 | 115.50 |
| July | 23.30 | 26-JUL-09:00 | 26.10 | 24.10 | 3.60 | 24.66 | 338.00 | 251.50 |
| August | 23.90 | 08-AUG-19:00 | 26.10 | 24.51 | 1.50 | 24.83 | 0.00 | 0.00 |
| September | 23.30 | 16-SEP-16:00 | 25.60 | 23.89 | 2.10 | 22.13 | 108.00 | 57.50 |
| October | 22.20 | 18-OCT-14:00 | 25.00 | 23.04 | 4.60 | 23.32 | 234.50 | 2.00 |
| November | 17.20 | 04-NOV-13:00 | 17.80 | 17.48 | 3.60 | 15.02 | 276.50 | 2.50 |
| December | 16.70 | 13-DEC-16:19 | 17.03 | 16.82 | 2.93 | 14.10 | 54.00 | 4.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 15.00 | 17.03 | 15.81 | 0.00 | 12.41 | 0.00 | 0.00 | |
| Maximum of Months | 23.90 | 28.30 | 24.51 | 13.90 | 24.83 | 338.00 | 251.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 13.74 | 22.89 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 13.65 | 27.55 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 15.17 | 38.46 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 17.98 | 47.59 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 21.32 | 52.44 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 24.28 | 55.84 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 26.07 | 52.33 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 26.20 | 48.31 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 24.63 | 36.35 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 21.78 | 31.91 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 18.45 | 24.33 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 15.51 | 20.76 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.94 | 38.29 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 13.65 | 20.76 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 26.20 | 55.84 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116885E+10 | -982533312.6 | 0.00 | 0.00 | 744.00 | 0.00 | -186315682.9 | 59.44 | 0.00 | 0.00 |
| February | 0.105614E+10 | -889196309.4 | 0.00 | 0.00 | 672.00 | 0.00 | -166948555.1 | 59.44 | 0.00 | 0.00 |
| March | 0.113353E+10 | -951830716.5 | 0.00 | 0.00 | 744.00 | 0.00 | -181699091.1 | 59.44 | 0.00 | 0.00 |
| April | 0.103461E+10 | -862682345.2 | 0.00 | 0.00 | 720.00 | 0.00 | -171931554.2 | 59.44 | 0.00 | 0.00 |
| May | 0.993443E+09 | -819693073.9 | 0.00 | 0.00 | 744.00 | 0.00 | -173750147.4 | 59.44 | 0.00 | 0.00 |
| June | 0.898516E+09 | -731537888.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166978059.0 | 59.44 | 0.00 | 0.00 |
| July | 0.889942E+09 | -717455390.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172486145.7 | 59.44 | 0.00 | 0.00 |
| August | 0.887212E+09 | -714728992.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172482605.2 | 59.44 | 0.00 | 0.00 |
| September | 0.891393E+09 | -724396156.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166996934.5 | 59.44 | 0.00 | 0.00 |
| October | 0.984343E+09 | -809662764.5 | 0.00 | 0.00 | 744.00 | 0.00 | -174680459.3 | 59.44 | 0.00 | 0.00 |
| November | 0.102548E+10 | -853014323.3 | 0.00 | 0.00 | 720.00 | 0.00 | -172469436.6 | 59.44 | 0.00 | 0.00 |
| December | 0.112920E+10 | -944581791.1 | 0.00 | 0.00 | 744.00 | 0.00 | -184613366.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120927E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209135E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887212E+09 | -982533312.6 | 0.00 | 0.00 | 672.00 | 0.00 | -186315682.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116885E+10 | -714728992.1 | 0.00 | 0.00 | 744.00 | 0.00 | -166948555.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116910E+10 | -982533040.2 | 0.00 | 0.00 | 744.00 | 0.00 | -186563681.4 | 59.44 | 0.00 | 0.00 |
| February | 0.105714E+10 | -889193782.3 | 0.00 | 0.00 | 672.00 | 0.00 | -167947561.9 | 59.44 | 0.00 | 0.00 |
| March | 0.113589E+10 | -951830409.7 | 0.00 | 0.00 | 744.00 | 0.00 | -184055339.5 | 59.44 | 0.00 | 0.00 |
| April | 0.103587E+10 | -862684922.0 | 0.00 | 0.00 | 720.00 | 0.00 | -173184809.9 | 59.44 | 0.00 | 0.00 |
| May | 0.993637E+09 | -819692930.6 | 0.00 | 0.00 | 744.00 | 0.00 | -173944359.1 | 59.44 | 0.00 | 0.00 |
| June | 0.898504E+09 | -731533646.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166970842.7 | 59.44 | 0.00 | 0.00 |
| July | 0.889945E+09 | -717444412.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172500113.7 | 59.44 | 0.00 | 0.00 |
| August | 0.887208E+09 | -714716658.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172491628.5 | 59.44 | 0.00 | 0.00 |
| September | 0.891423E+09 | -724399553.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167023426.3 | 59.44 | 0.00 | 0.00 |
| October | 0.985857E+09 | -809669287.2 | 0.00 | 0.00 | 744.00 | 0.00 | -176187763.2 | 59.44 | 0.00 | 0.00 |
| November | 0.102904E+10 | -853013169.9 | 0.00 | 0.00 | 720.00 | 0.00 | -176028046.8 | 59.44 | 0.00 | 0.00 |
| December | 0.113069E+10 | -944577633.9 | 0.00 | 0.00 | 744.00 | 0.00 | -186109427.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121043E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210301E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887208E+09 | -982533040.2 | 0.00 | 0.00 | 672.00 | 0.00 | -186563681.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116910E+10 | -714716658.6 | 0.00 | 0.00 | 744.00 | 0.00 | -166970842.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116910E+10 | -982533091.8 | 0.00 | 0.00 | 744.00 | 0.00 | -186567071.2 | 59.44 | 0.00 | 0.00 |
| February | 0.105714E+10 | -889193804.5 | 0.00 | 0.00 | 672.00 | 0.00 | -167941848.6 | 59.44 | 0.00 | 0.00 |
| March | 0.113604E+10 | -951829854.7 | 0.00 | 0.00 | 744.00 | 0.00 | -184210488.9 | 59.44 | 0.00 | 0.00 |
| April | 0.103588E+10 | -862684584.3 | 0.00 | 0.00 | 720.00 | 0.00 | -173198038.0 | 59.44 | 0.00 | 0.00 |
| May | 0.993585E+09 | -819692722.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173892222.3 | 59.44 | 0.00 | 0.00 |
| June | 0.898497E+09 | -731537521.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166959323.6 | 59.44 | 0.00 | 0.00 |
| July | 0.889946E+09 | -717444306.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172501687.8 | 59.44 | 0.00 | 0.00 |
| August | 0.887208E+09 | -714714885.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172493048.3 | 59.44 | 0.00 | 0.00 |
| September | 0.891423E+09 | -724399614.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167023406.8 | 59.44 | 0.00 | 0.00 |
| October | 0.985762E+09 | -809669643.7 | 0.00 | 0.00 | 744.00 | 0.00 | -176092748.9 | 59.44 | 0.00 | 0.00 |
| November | 0.102909E+10 | -853012383.4 | 0.00 | 0.00 | 720.00 | 0.00 | -176082523.3 | 59.44 | 0.00 | 0.00 |
| December | 0.113071E+10 | -944578789.6 | 0.00 | 0.00 | 744.00 | 0.00 | -186132588.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121044E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210309E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887208E+09 | -982533091.8 | 0.00 | 0.00 | 672.00 | 0.00 | -186567071.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116910E+10 | -714714885.1 | 0.00 | 0.00 | 744.00 | 0.00 | -166959323.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116905E+10 | -982533114.7 | 0.00 | 0.00 | 744.00 | 0.00 | -186511979.1 | 59.44 | 0.00 | 0.00 |
| February | 0.105695E+10 | -889195272.6 | 0.00 | 0.00 | 672.00 | 0.00 | -167756507.3 | 59.44 | 0.00 | 0.00 |
| March | 0.113525E+10 | -951828835.0 | 0.00 | 0.00 | 744.00 | 0.00 | -183416973.8 | 59.44 | 0.00 | 0.00 |
| April | 0.103461E+10 | -862681130.2 | 0.00 | 0.00 | 720.00 | 0.00 | -171931246.0 | 59.44 | 0.00 | 0.00 |
| May | 0.992979E+09 | -819689848.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173289383.9 | 59.44 | 0.00 | 0.00 |
| June | 0.898469E+09 | -731528368.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166940864.9 | 59.44 | 0.00 | 0.00 |
| July | 0.889942E+09 | -717448066.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172493439.6 | 59.44 | 0.00 | 0.00 |
| August | 0.887209E+09 | -714720270.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172488787.7 | 59.44 | 0.00 | 0.00 |
| September | 0.891353E+09 | -724399480.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166953378.4 | 59.44 | 0.00 | 0.00 |
| October | 0.984670E+09 | -809663680.3 | 0.00 | 0.00 | 744.00 | 0.00 | -175005992.5 | 59.44 | 0.00 | 0.00 |
| November | 0.102789E+10 | -853018632.0 | 0.00 | 0.00 | 720.00 | 0.00 | -174866438.4 | 59.44 | 0.00 | 0.00 |
| December | 0.113049E+10 | -944578788.5 | 0.00 | 0.00 | 744.00 | 0.00 | -185913489.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120989E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209757E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887209E+09 | -982533114.7 | 0.00 | 0.00 | 672.00 | 0.00 | -186511979.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116905E+10 | -714720270.9 | 0.00 | 0.00 | 744.00 | 0.00 | -166940864.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116905E+10 | -982533105.0 | 0.00 | 0.00 | 744.00 | 0.00 | -186511966.3 | 59.44 | 0.00 | 0.00 |
| February | 0.105695E+10 | -889195268.4 | 0.00 | 0.00 | 672.00 | 0.00 | -167752433.3 | 59.44 | 0.00 | 0.00 |
| March | 0.113526E+10 | -951829354.1 | 0.00 | 0.00 | 744.00 | 0.00 | -183425720.4 | 59.44 | 0.00 | 0.00 |
| April | 0.103462E+10 | -862680515.7 | 0.00 | 0.00 | 720.00 | 0.00 | -171938780.6 | 59.44 | 0.00 | 0.00 |
| May | 0.992978E+09 | -819689656.1 | 0.00 | 0.00 | 744.00 | 0.00 | -173288324.7 | 59.44 | 0.00 | 0.00 |
| June | 0.898469E+09 | -731528697.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166940567.5 | 59.44 | 0.00 | 0.00 |
| July | 0.889942E+09 | -717447931.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172493600.2 | 59.44 | 0.00 | 0.00 |
| August | 0.887209E+09 | -714720156.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172488877.7 | 59.44 | 0.00 | 0.00 |
| September | 0.891353E+09 | -724399506.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166953451.9 | 59.44 | 0.00 | 0.00 |
| October | 0.984668E+09 | -809663544.6 | 0.00 | 0.00 | 744.00 | 0.00 | -175004578.5 | 59.44 | 0.00 | 0.00 |
| November | 0.102789E+10 | -853018588.5 | 0.00 | 0.00 | 720.00 | 0.00 | -174871769.8 | 59.44 | 0.00 | 0.00 |
| December | 0.113049E+10 | -944578830.1 | 0.00 | 0.00 | 744.00 | 0.00 | -185914171.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120989E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209758E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887209E+09 | -982533105.0 | 0.00 | 0.00 | 672.00 | 0.00 | -186511966.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116905E+10 | -714720156.8 | 0.00 | 0.00 | 744.00 | 0.00 | -166940567.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116859E+10 | -982534370.0 | 0.00 | 0.00 | 744.00 | 0.00 | -186052887.1 | 59.44 | 0.00 | 0.00 |
| February | 0.105551E+10 | -889194150.7 | 0.00 | 0.00 | 672.00 | 0.00 | -166316244.0 | 59.44 | 0.00 | 0.00 |
| March | 0.113164E+10 | -951830363.9 | 0.00 | 0.00 | 744.00 | 0.00 | -179806567.9 | 59.44 | 0.00 | 0.00 |
| April | 0.103299E+10 | -862684256.1 | 0.00 | 0.00 | 720.00 | 0.00 | -170308673.9 | 59.44 | 0.00 | 0.00 |
| May | 0.992801E+09 | -819692460.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173108489.1 | 59.44 | 0.00 | 0.00 |
| June | 0.898472E+09 | -731529989.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166941666.7 | 59.44 | 0.00 | 0.00 |
| July | 0.889941E+09 | -717445724.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172495742.0 | 59.44 | 0.00 | 0.00 |
| August | 0.887209E+09 | -714718617.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172490099.6 | 59.44 | 0.00 | 0.00 |
| September | 0.891337E+09 | -724399927.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166937166.0 | 59.44 | 0.00 | 0.00 |
| October | 0.983240E+09 | -809664602.6 | 0.00 | 0.00 | 744.00 | 0.00 | -173575063.9 | 59.44 | 0.00 | 0.00 |
| November | 0.102364E+10 | -853019692.2 | 0.00 | 0.00 | 720.00 | 0.00 | -170622780.3 | 59.44 | 0.00 | 0.00 |
| December | 0.112803E+10 | -944579175.4 | 0.00 | 0.00 | 744.00 | 0.00 | -183450264.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120834E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208211E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887209E+09 | -982534370.0 | 0.00 | 0.00 | 672.00 | 0.00 | -186052887.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116859E+10 | -714718617.3 | 0.00 | 0.00 | 744.00 | 0.00 | -166316244.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116867E+10 | -982534096.5 | 0.00 | 0.00 | 744.00 | 0.00 | -186139220.9 | 59.44 | 0.00 | 0.00 |
| February | 0.105551E+10 | -889195314.6 | 0.00 | 0.00 | 672.00 | 0.00 | -166309746.3 | 59.44 | 0.00 | 0.00 |
| March | 0.113141E+10 | -951830129.7 | 0.00 | 0.00 | 744.00 | 0.00 | -179583807.4 | 59.44 | 0.00 | 0.00 |
| April | 0.103275E+10 | -862680716.1 | 0.00 | 0.00 | 720.00 | 0.00 | -170072815.9 | 59.44 | 0.00 | 0.00 |
| May | 0.992703E+09 | -819690141.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173013216.4 | 59.44 | 0.00 | 0.00 |
| June | 0.898460E+09 | -731537820.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166922351.4 | 59.44 | 0.00 | 0.00 |
| July | 0.889943E+09 | -717444201.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172498695.0 | 59.44 | 0.00 | 0.00 |
| August | 0.887208E+09 | -714715035.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172492935.4 | 59.44 | 0.00 | 0.00 |
| September | 0.891329E+09 | -724399892.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166928900.3 | 59.44 | 0.00 | 0.00 |
| October | 0.983113E+09 | -809664325.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173448851.8 | 59.44 | 0.00 | 0.00 |
| November | 0.102352E+10 | -853020316.2 | 0.00 | 0.00 | 720.00 | 0.00 | -170498235.5 | 59.44 | 0.00 | 0.00 |
| December | 0.112806E+10 | -944578708.0 | 0.00 | 0.00 | 744.00 | 0.00 | -183484336.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120827E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208139E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887208E+09 | -982534096.5 | 0.00 | 0.00 | 672.00 | 0.00 | -186139220.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116867E+10 | -714715035.6 | 0.00 | 0.00 | 744.00 | 0.00 | -166309746.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215085E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185783152.7 | 59.44 | 0.00 | 0.00 |
| February | 0.194390E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165508737.9 | 59.44 | 0.00 | 0.00 |
| March | 0.208128E+10 | -0.190366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177616241.9 | 59.44 | 0.00 | 0.00 |
| April | 0.189398E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168608140.7 | 59.44 | 0.00 | 0.00 |
| May | 0.181212E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172733385.6 | 59.44 | 0.00 | 0.00 |
| June | 0.163002E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166939649.3 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143492E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484363.2 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482830.8 | 59.44 | 0.00 | 0.00 |
| September | 0.161587E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167069800.9 | 59.44 | 0.00 | 0.00 |
| October | 0.179484E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175496922.2 | 59.44 | 0.00 | 0.00 |
| November | 0.187909E+10 | -0.170604E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -173052157.7 | 59.44 | 0.00 | 0.00 |
| December | 0.207319E+10 | -0.188917E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184019097.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220845E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208179E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -185783152.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215085E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -165508737.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215149E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186420952.6 | 59.44 | 0.00 | 0.00 |
| February | 0.194530E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166910194.2 | 59.44 | 0.00 | 0.00 |
| March | 0.208376E+10 | -0.190366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180101828.2 | 59.44 | 0.00 | 0.00 |
| April | 0.189460E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169228073.7 | 59.44 | 0.00 | 0.00 |
| May | 0.181215E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172761008.7 | 59.44 | 0.00 | 0.00 |
| June | 0.163001E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166936351.8 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143492E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484478.4 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482825.7 | 59.44 | 0.00 | 0.00 |
| September | 0.161591E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167109035.0 | 59.44 | 0.00 | 0.00 |
| October | 0.179641E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177073452.2 | 59.44 | 0.00 | 0.00 |
| November | 0.188253E+10 | -0.170604E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176495862.3 | 59.44 | 0.00 | 0.00 |
| December | 0.207501E+10 | -0.188917E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185843951.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220965E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209385E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186420952.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215149E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166910194.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215086E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185796603.4 | 59.44 | 0.00 | 0.00 |
| February | 0.194380E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165404142.3 | 59.44 | 0.00 | 0.00 |
| March | 0.208117E+10 | -0.190367E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177496436.0 | 59.44 | 0.00 | 0.00 |
| April | 0.189387E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168501038.4 | 59.44 | 0.00 | 0.00 |
| May | 0.181209E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172697678.2 | 59.44 | 0.00 | 0.00 |
| June | 0.163001E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166935748.3 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143492E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484438.0 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482841.4 | 59.44 | 0.00 | 0.00 |
| September | 0.161587E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167069371.1 | 59.44 | 0.00 | 0.00 |
| October | 0.179481E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175473135.3 | 59.44 | 0.00 | 0.00 |
| November | 0.187901E+10 | -0.170604E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -172970784.4 | 59.44 | 0.00 | 0.00 |
| December | 0.207318E+10 | -0.188917E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184015621.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220840E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208133E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -185796603.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215086E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -165404142.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215150E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186427783.1 | 59.44 | 0.00 | 0.00 |
| February | 0.194523E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166839355.1 | 59.44 | 0.00 | 0.00 |
| March | 0.208380E+10 | -0.190366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180133708.2 | 59.44 | 0.00 | 0.00 |
| April | 0.189448E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169107046.8 | 59.44 | 0.00 | 0.00 |
| May | 0.181212E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172730016.2 | 59.44 | 0.00 | 0.00 |
| June | 0.163001E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166934409.1 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143492E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172484536.2 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482842.3 | 59.44 | 0.00 | 0.00 |
| September | 0.161591E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167107226.7 | 59.44 | 0.00 | 0.00 |
| October | 0.179626E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176925845.1 | 59.44 | 0.00 | 0.00 |
| November | 0.188260E+10 | -0.170604E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176566644.1 | 59.44 | 0.00 | 0.00 |
| December | 0.207504E+10 | -0.188917E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185876787.7 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220963E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209362E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186427783.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215150E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166839355.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215134E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186274357.5 | 59.44 | 0.00 | 0.00 |
| February | 0.194457E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166176244.3 | 59.44 | 0.00 | 0.00 |
| March | 0.208244E+10 | -0.190366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178773417.2 | 59.44 | 0.00 | 0.00 |
| April | 0.189389E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168513321.3 | 59.44 | 0.00 | 0.00 |
| May | 0.181199E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172594145.0 | 59.44 | 0.00 | 0.00 |
| June | 0.163000E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166924296.5 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143491E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485261.4 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486037.8 | 59.44 | 0.00 | 0.00 |
| September | 0.161579E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166986433.0 | 59.44 | 0.00 | 0.00 |
| October | 0.179493E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175594383.7 | 59.44 | 0.00 | 0.00 |
| November | 0.188114E+10 | -0.170603E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175105046.7 | 59.44 | 0.00 | 0.00 |
| December | 0.207462E+10 | -0.188917E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185450456.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220900E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208736E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186274357.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215134E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166176244.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215134E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186273927.2 | 59.44 | 0.00 | 0.00 |
| February | 0.194456E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166167583.5 | 59.44 | 0.00 | 0.00 |
| March | 0.208244E+10 | -0.190366E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178775576.2 | 59.44 | 0.00 | 0.00 |
| April | 0.189388E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168505796.8 | 59.44 | 0.00 | 0.00 |
| May | 0.181199E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172593710.9 | 59.44 | 0.00 | 0.00 |
| June | 0.163000E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166924399.5 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143491E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485246.2 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486038.0 | 59.44 | 0.00 | 0.00 |
| September | 0.161579E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166986614.0 | 59.44 | 0.00 | 0.00 |
| October | 0.179493E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175589179.3 | 59.44 | 0.00 | 0.00 |
| November | 0.188115E+10 | -0.170603E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -175112195.5 | 59.44 | 0.00 | 0.00 |
| December | 0.207462E+10 | -0.188917E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185451300.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220900E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.208735E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186273927.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215134E+10 | -0.142945E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166167583.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215007E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185001835.2 | 59.44 | 0.00 | 0.00 |
| February | 0.194262E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -164224200.3 | 59.44 | 0.00 | 0.00 |
| March | 0.207946E+10 | -0.190367E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175798366.0 | 59.44 | 0.00 | 0.00 |
| April | 0.189319E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167815971.3 | 59.44 | 0.00 | 0.00 |
| May | 0.181197E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172578274.4 | 59.44 | 0.00 | 0.00 |
| June | 0.163000E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166923857.2 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143492E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485396.0 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142946E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483577.9 | 59.44 | 0.00 | 0.00 |
| September | 0.161576E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166958678.7 | 59.44 | 0.00 | 0.00 |
| October | 0.179339E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174050747.9 | 59.44 | 0.00 | 0.00 |
| November | 0.187686E+10 | -0.170604E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170818880.8 | 59.44 | 0.00 | 0.00 |
| December | 0.207162E+10 | -0.188916E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182458806.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220743E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.207160E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -185001835.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215007E+10 | -0.142946E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164224200.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.215007E+10 | -0.196507E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184999511.1 | 59.44 | 0.00 | 0.00 |
| February | 0.194261E+10 | -0.177839E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -164217497.9 | 59.44 | 0.00 | 0.00 |
| March | 0.207946E+10 | -0.190367E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175796781.5 | 59.44 | 0.00 | 0.00 |
| April | 0.189318E+10 | -0.172537E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167810849.6 | 59.44 | 0.00 | 0.00 |
| May | 0.181197E+10 | -0.163939E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172578047.4 | 59.44 | 0.00 | 0.00 |
| June | 0.163000E+10 | -0.146308E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166923791.0 | 59.44 | 0.00 | 0.00 |
| July | 0.160740E+10 | -0.143492E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485397.4 | 59.44 | 0.00 | 0.00 |
| August | 0.160194E+10 | -0.142946E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483578.0 | 59.44 | 0.00 | 0.00 |
| September | 0.161576E+10 | -0.144880E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166958743.9 | 59.44 | 0.00 | 0.00 |
| October | 0.179340E+10 | -0.161934E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174055495.7 | 59.44 | 0.00 | 0.00 |
| November | 0.187685E+10 | -0.170604E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170814896.4 | 59.44 | 0.00 | 0.00 |
| December | 0.207162E+10 | -0.188916E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182453925.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.220743E+11 | -0.200027E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.207158E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.160194E+10 | -0.196507E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -184999511.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.215007E+10 | -0.142946E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164217497.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116844E+10 | -982534005.0 | 0.00 | 0.00 | 744.00 | 0.00 | -185907247.8 | 59.44 | 0.00 | 0.00 |
| February | 0.105573E+10 | -889194623.3 | 0.00 | 0.00 | 672.00 | 0.00 | -166536475.5 | 59.44 | 0.00 | 0.00 |
| March | 0.113248E+10 | -951829914.2 | 0.00 | 0.00 | 744.00 | 0.00 | -180647603.7 | 59.44 | 0.00 | 0.00 |
| April | 0.103430E+10 | -862684450.7 | 0.00 | 0.00 | 720.00 | 0.00 | -171615681.3 | 59.44 | 0.00 | 0.00 |
| May | 0.993927E+09 | -819691507.1 | 0.00 | 0.00 | 744.00 | 0.00 | -174235260.5 | 59.44 | 0.00 | 0.00 |
| June | 0.898839E+09 | -731542086.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167296939.5 | 59.44 | 0.00 | 0.00 |
| July | 0.889996E+09 | -717445825.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172549992.9 | 59.44 | 0.00 | 0.00 |
| August | 0.887213E+09 | -714713061.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172499843.6 | 59.44 | 0.00 | 0.00 |
| September | 0.892392E+09 | -724405178.9 | 0.00 | 0.00 | 720.00 | 0.00 | -167986529.1 | 59.44 | 0.00 | 0.00 |
| October | 0.988746E+09 | -809666797.2 | 0.00 | 0.00 | 744.00 | 0.00 | -179079348.8 | 59.44 | 0.00 | 0.00 |
| November | 0.102902E+10 | -853020329.7 | 0.00 | 0.00 | 720.00 | 0.00 | -176003790.6 | 59.44 | 0.00 | 0.00 |
| December | 0.112941E+10 | -944579282.3 | 0.00 | 0.00 | 744.00 | 0.00 | -184835710.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121005E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209919E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887213E+09 | -982534005.0 | 0.00 | 0.00 | 672.00 | 0.00 | -185907247.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116844E+10 | -714713061.0 | 0.00 | 0.00 | 744.00 | 0.00 | -166536475.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116900E+10 | -982532775.4 | 0.00 | 0.00 | 744.00 | 0.00 | -186469828.5 | 59.44 | 0.00 | 0.00 |
| February | 0.105657E+10 | -889195390.5 | 0.00 | 0.00 | 672.00 | 0.00 | -167374701.3 | 59.44 | 0.00 | 0.00 |
| March | 0.113401E+10 | -951830857.8 | 0.00 | 0.00 | 744.00 | 0.00 | -182176628.6 | 59.44 | 0.00 | 0.00 |
| April | 0.103482E+10 | -862685219.7 | 0.00 | 0.00 | 720.00 | 0.00 | -172137843.8 | 59.44 | 0.00 | 0.00 |
| May | 0.993973E+09 | -819698910.9 | 0.00 | 0.00 | 744.00 | 0.00 | -174274455.3 | 59.44 | 0.00 | 0.00 |
| June | 0.898816E+09 | -731528946.2 | 0.00 | 0.00 | 720.00 | 0.00 | -167286977.2 | 59.44 | 0.00 | 0.00 |
| July | 0.890000E+09 | -717445716.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172554186.1 | 59.44 | 0.00 | 0.00 |
| August | 0.887214E+09 | -714715975.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172497656.4 | 59.44 | 0.00 | 0.00 |
| September | 0.892534E+09 | -724404571.6 | 0.00 | 0.00 | 720.00 | 0.00 | -168129565.2 | 59.44 | 0.00 | 0.00 |
| October | 0.990149E+09 | -809661357.1 | 0.00 | 0.00 | 744.00 | 0.00 | -180487288.4 | 59.44 | 0.00 | 0.00 |
| November | 0.103098E+10 | -853014030.1 | 0.00 | 0.00 | 720.00 | 0.00 | -177961140.3 | 59.44 | 0.00 | 0.00 |
| December | 0.113065E+10 | -944579317.2 | 0.00 | 0.00 | 744.00 | 0.00 | -186074300.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121087E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210742E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887214E+09 | -982532775.4 | 0.00 | 0.00 | 672.00 | 0.00 | -186469828.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116900E+10 | -714715975.2 | 0.00 | 0.00 | 744.00 | 0.00 | -167286977.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116849E+10 | -982534308.5 | 0.00 | 0.00 | 744.00 | 0.00 | -185958727.4 | 59.44 | 0.00 | 0.00 |
| February | 0.105565E+10 | -889194496.4 | 0.00 | 0.00 | 672.00 | 0.00 | -166457850.5 | 59.44 | 0.00 | 0.00 |
| March | 0.113240E+10 | -951829915.9 | 0.00 | 0.00 | 744.00 | 0.00 | -180565175.2 | 59.44 | 0.00 | 0.00 |
| April | 0.103418E+10 | -862684386.1 | 0.00 | 0.00 | 720.00 | 0.00 | -171492358.7 | 59.44 | 0.00 | 0.00 |
| May | 0.993818E+09 | -819690077.2 | 0.00 | 0.00 | 744.00 | 0.00 | -174128358.1 | 59.44 | 0.00 | 0.00 |
| June | 0.898790E+09 | -731540644.5 | 0.00 | 0.00 | 720.00 | 0.00 | -167249313.5 | 59.44 | 0.00 | 0.00 |
| July | 0.889996E+09 | -717462281.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172533500.6 | 59.44 | 0.00 | 0.00 |
| August | 0.887218E+09 | -714735062.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172483319.3 | 59.44 | 0.00 | 0.00 |
| September | 0.892362E+09 | -724399377.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167962708.2 | 59.44 | 0.00 | 0.00 |
| October | 0.988575E+09 | -809665209.5 | 0.00 | 0.00 | 744.00 | 0.00 | -178909973.6 | 59.44 | 0.00 | 0.00 |
| November | 0.102898E+10 | -853015026.6 | 0.00 | 0.00 | 720.00 | 0.00 | -175960144.4 | 59.44 | 0.00 | 0.00 |
| December | 0.112945E+10 | -944579065.7 | 0.00 | 0.00 | 744.00 | 0.00 | -184866471.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120999E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209857E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887218E+09 | -982534308.5 | 0.00 | 0.00 | 672.00 | 0.00 | -185958727.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116849E+10 | -714735062.4 | 0.00 | 0.00 | 744.00 | 0.00 | -166457850.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116902E+10 | -982532748.7 | 0.00 | 0.00 | 744.00 | 0.00 | -186487471.8 | 59.44 | 0.00 | 0.00 |
| February | 0.105656E+10 | -889194609.7 | 0.00 | 0.00 | 672.00 | 0.00 | -167365617.5 | 59.44 | 0.00 | 0.00 |
| March | 0.113417E+10 | -951830236.7 | 0.00 | 0.00 | 744.00 | 0.00 | -182336743.7 | 59.44 | 0.00 | 0.00 |
| April | 0.103470E+10 | -862684732.9 | 0.00 | 0.00 | 720.00 | 0.00 | -172015066.8 | 59.44 | 0.00 | 0.00 |
| May | 0.993866E+09 | -819698111.7 | 0.00 | 0.00 | 744.00 | 0.00 | -174167731.7 | 59.44 | 0.00 | 0.00 |
| June | 0.898772E+09 | -731538877.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167233564.8 | 59.44 | 0.00 | 0.00 |
| July | 0.890002E+09 | -717456294.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172545259.2 | 59.44 | 0.00 | 0.00 |
| August | 0.887216E+09 | -714725071.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172490494.1 | 59.44 | 0.00 | 0.00 |
| September | 0.892490E+09 | -724403430.3 | 0.00 | 0.00 | 720.00 | 0.00 | -168086927.9 | 59.44 | 0.00 | 0.00 |
| October | 0.990016E+09 | -809662012.6 | 0.00 | 0.00 | 744.00 | 0.00 | -180353558.0 | 59.44 | 0.00 | 0.00 |
| November | 0.103117E+10 | -853013802.7 | 0.00 | 0.00 | 720.00 | 0.00 | -178154838.5 | 59.44 | 0.00 | 0.00 |
| December | 0.113069E+10 | -944581419.6 | 0.00 | 0.00 | 744.00 | 0.00 | -186110699.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121087E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210735E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887216E+09 | -982532748.7 | 0.00 | 0.00 | 672.00 | 0.00 | -186487471.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116902E+10 | -714725071.9 | 0.00 | 0.00 | 744.00 | 0.00 | -167233564.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116894E+10 | -982532572.8 | 0.00 | 0.00 | 744.00 | 0.00 | -186412161.6 | 59.44 | 0.00 | 0.00 |
| February | 0.105645E+10 | -889194961.8 | 0.00 | 0.00 | 672.00 | 0.00 | -167251581.0 | 59.44 | 0.00 | 0.00 |
| March | 0.113380E+10 | -951831230.0 | 0.00 | 0.00 | 744.00 | 0.00 | -181965860.0 | 59.44 | 0.00 | 0.00 |
| April | 0.103411E+10 | -862683324.1 | 0.00 | 0.00 | 720.00 | 0.00 | -171424806.5 | 59.44 | 0.00 | 0.00 |
| May | 0.993413E+09 | -819690447.5 | 0.00 | 0.00 | 744.00 | 0.00 | -173722258.0 | 59.44 | 0.00 | 0.00 |
| June | 0.898675E+09 | -731529670.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167145541.5 | 59.44 | 0.00 | 0.00 |
| July | 0.889959E+09 | -717448891.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172510008.7 | 59.44 | 0.00 | 0.00 |
| August | 0.887211E+09 | -714720141.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172490645.3 | 59.44 | 0.00 | 0.00 |
| September | 0.892144E+09 | -724406484.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167737560.4 | 59.44 | 0.00 | 0.00 |
| October | 0.989580E+09 | -809672806.4 | 0.00 | 0.00 | 744.00 | 0.00 | -179907437.9 | 59.44 | 0.00 | 0.00 |
| November | 0.103074E+10 | -853017202.5 | 0.00 | 0.00 | 720.00 | 0.00 | -177725749.9 | 59.44 | 0.00 | 0.00 |
| December | 0.113057E+10 | -944578780.2 | 0.00 | 0.00 | 744.00 | 0.00 | -185991674.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121056E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210429E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887211E+09 | -982532572.8 | 0.00 | 0.00 | 672.00 | 0.00 | -186412161.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116894E+10 | -714720141.1 | 0.00 | 0.00 | 744.00 | 0.00 | -167145541.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116895E+10 | -982532572.0 | 0.00 | 0.00 | 744.00 | 0.00 | -186412756.5 | 59.44 | 0.00 | 0.00 |
| February | 0.105644E+10 | -889194920.5 | 0.00 | 0.00 | 672.00 | 0.00 | -167247846.0 | 59.44 | 0.00 | 0.00 |
| March | 0.113381E+10 | -951831345.5 | 0.00 | 0.00 | 744.00 | 0.00 | -181973782.7 | 59.44 | 0.00 | 0.00 |
| April | 0.103411E+10 | -862683444.1 | 0.00 | 0.00 | 720.00 | 0.00 | -171424798.1 | 59.44 | 0.00 | 0.00 |
| May | 0.993411E+09 | -819690463.7 | 0.00 | 0.00 | 744.00 | 0.00 | -173720888.6 | 59.44 | 0.00 | 0.00 |
| June | 0.898674E+09 | -731529713.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167144649.8 | 59.44 | 0.00 | 0.00 |
| July | 0.889959E+09 | -717448895.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172510285.3 | 59.44 | 0.00 | 0.00 |
| August | 0.887211E+09 | -714720136.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172490697.3 | 59.44 | 0.00 | 0.00 |
| September | 0.892145E+09 | -724406490.9 | 0.00 | 0.00 | 720.00 | 0.00 | -167738559.3 | 59.44 | 0.00 | 0.00 |
| October | 0.989572E+09 | -809672371.9 | 0.00 | 0.00 | 744.00 | 0.00 | -179899378.9 | 59.44 | 0.00 | 0.00 |
| November | 0.103076E+10 | -853017287.2 | 0.00 | 0.00 | 720.00 | 0.00 | -177737761.9 | 59.44 | 0.00 | 0.00 |
| December | 0.113057E+10 | -944578790.6 | 0.00 | 0.00 | 744.00 | 0.00 | -185993195.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.121056E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210429E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887211E+09 | -982532572.0 | 0.00 | 0.00 | 672.00 | 0.00 | -186412756.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116895E+10 | -714720136.6 | 0.00 | 0.00 | 744.00 | 0.00 | -167144649.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116816E+10 | -982532337.6 | 0.00 | 0.00 | 744.00 | 0.00 | -185623144.6 | 59.44 | 0.00 | 0.00 |
| February | 0.105525E+10 | -889193913.9 | 0.00 | 0.00 | 672.00 | 0.00 | -166052547.2 | 59.44 | 0.00 | 0.00 |
| March | 0.113167E+10 | -951828974.6 | 0.00 | 0.00 | 744.00 | 0.00 | -179842190.8 | 59.44 | 0.00 | 0.00 |
| April | 0.103342E+10 | -862686436.8 | 0.00 | 0.00 | 720.00 | 0.00 | -170729452.3 | 59.44 | 0.00 | 0.00 |
| May | 0.993367E+09 | -819691687.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173675001.3 | 59.44 | 0.00 | 0.00 |
| June | 0.898698E+09 | -731538800.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167159591.3 | 59.44 | 0.00 | 0.00 |
| July | 0.889954E+09 | -717454357.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172500061.3 | 59.44 | 0.00 | 0.00 |
| August | 0.887212E+09 | -714725447.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172486178.2 | 59.44 | 0.00 | 0.00 |
| September | 0.892014E+09 | -724400355.9 | 0.00 | 0.00 | 720.00 | 0.00 | -167613615.0 | 59.44 | 0.00 | 0.00 |
| October | 0.987722E+09 | -809669202.5 | 0.00 | 0.00 | 744.00 | 0.00 | -178052685.2 | 59.44 | 0.00 | 0.00 |
| November | 0.102801E+10 | -853022391.3 | 0.00 | 0.00 | 720.00 | 0.00 | -174991228.2 | 59.44 | 0.00 | 0.00 |
| December | 0.112882E+10 | -944577789.2 | 0.00 | 0.00 | 744.00 | 0.00 | -184238729.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120943E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209296E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887212E+09 | -982532337.6 | 0.00 | 0.00 | 672.00 | 0.00 | -185623144.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116816E+10 | -714725447.9 | 0.00 | 0.00 | 744.00 | 0.00 | -166052547.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.116815E+10 | -982532322.5 | 0.00 | 0.00 | 744.00 | 0.00 | -185621661.5 | 59.44 | 0.00 | 0.00 |
| February | 0.105524E+10 | -889194023.8 | 0.00 | 0.00 | 672.00 | 0.00 | -166044807.5 | 59.44 | 0.00 | 0.00 |
| March | 0.113167E+10 | -951828657.0 | 0.00 | 0.00 | 744.00 | 0.00 | -179838713.1 | 59.44 | 0.00 | 0.00 |
| April | 0.103342E+10 | -862686054.2 | 0.00 | 0.00 | 720.00 | 0.00 | -170731055.7 | 59.44 | 0.00 | 0.00 |
| May | 0.993366E+09 | -819692083.5 | 0.00 | 0.00 | 744.00 | 0.00 | -173674415.5 | 59.44 | 0.00 | 0.00 |
| June | 0.898698E+09 | -731539307.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167158200.8 | 59.44 | 0.00 | 0.00 |
| July | 0.889954E+09 | -717455167.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172499194.9 | 59.44 | 0.00 | 0.00 |
| August | 0.887212E+09 | -714726864.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172485295.8 | 59.44 | 0.00 | 0.00 |
| September | 0.892015E+09 | -724399840.3 | 0.00 | 0.00 | 720.00 | 0.00 | -167615360.2 | 59.44 | 0.00 | 0.00 |
| October | 0.987719E+09 | -809669545.7 | 0.00 | 0.00 | 744.00 | 0.00 | -178049908.5 | 59.44 | 0.00 | 0.00 |
| November | 0.102801E+10 | -853022375.8 | 0.00 | 0.00 | 720.00 | 0.00 | -174989743.4 | 59.44 | 0.00 | 0.00 |
| December | 0.112881E+10 | -944577873.5 | 0.00 | 0.00 | 744.00 | 0.00 | -184235410.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.120943E+11 | -0.100013E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.209294E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.887212E+09 | -982532322.5 | 0.00 | 0.00 | 672.00 | 0.00 | -185621661.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.116815E+10 | -714726864.0 | 0.00 | 0.00 | 744.00 | 0.00 | -166044807.5 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 290.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 263.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 351.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 369.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 407.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 411.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 411.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 390.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 298.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 293.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 285.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4071.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 263.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 411.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.222349E+10 | 2361.39 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.148099E+10 | 3021.49 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.313796E+09 | 1080.75 | 18-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 77562684.86 | 907.63 | 06-APR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 939594.18 | 129.30 | 26-OCT-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.126133E+09 | 1153.64 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.963762E+09 | 1602.58 | 17-DEC-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.518667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.222349E+10 | 3021.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.294319E+10 | 2522.67 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.197910E+10 | 3140.72 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.600110E+09 | 1259.07 | 18-MAR-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.132560E+09 | 981.20 | 06-APR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 14428729.37 | 457.62 | 26-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.342715E+09 | 1406.75 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.155565E+10 | 1838.26 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.756775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.294319E+10 | 3140.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.717283E+09 | 9365.09 | 03-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.469902E+09 | 9365.09 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 19571737.75 | 7915.17 | 22-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 226173.75 | 1852.82 | 06-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 1534447.69 | 8216.98 | 22-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 82933931.62 | 9365.09 | 04-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.129145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.717283E+09 | 9365.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.294161E+10 | 2516.37 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.195704E+10 | 3155.51 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.592902E+09 | 1236.38 | 18-MAR-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.128395E+09 | 988.95 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 15854978.06 | 508.08 | 26-OCT-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.333058E+09 | 1396.87 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.153808E+10 | 1771.74 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.750694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.294161E+10 | 3155.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.200193E+10 | 1710.96 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.128073E+10 | 2159.09 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.282792E+09 | 779.49 | 18-MAR-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 36401133.78 | 503.91 | 07-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.149842E+09 | 928.20 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.941576E+09 | 1197.35 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.469327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.200193E+10 | 2159.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.200217E+10 | 1710.51 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.128011E+10 | 2160.02 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.283756E+09 | 781.51 | 18-MAR-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 36745598.44 | 505.28 | 07-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.149759E+09 | 928.09 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.941108E+09 | 1197.00 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.469365E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.200217E+10 | 2160.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.132444E+10 | 1541.19 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.828726E+09 | 2033.97 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 93498968.31 | 549.84 | 22-MAR-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 12119150.67 | 315.82 | 06-APR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 20624381.66 | 510.64 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.399005E+09 | 841.37 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.267842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.132444E+10 | 2033.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.147409E+10 | 1647.13 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.906651E+09 | 2154.24 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 92724923.92 | 550.12 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 9906828.91 | 287.27 | 06-APR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 19538398.55 | 505.89 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.436372E+09 | 848.85 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.293928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.147409E+10 | 2154.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.383575E+10 | 5169.00 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.232373E+10 | 6517.32 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.189676E+09 | 1759.66 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 13619831.22 | 801.25 | 06-APR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50878597.91 | 1279.41 | 25-OCT-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.432880E+09 | 3140.79 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.209384E+10 | 4211.58 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.894037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.383575E+10 | 6517.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.528630E+10 | 5450.61 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.320087E+10 | 6783.28 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.422311E+09 | 2246.54 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 46374739.06 | 1147.19 | 06-APR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.122683E+09 | 1782.08 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.997213E+09 | 3531.23 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.331209E+10 | 4512.48 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.133878E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.528630E+10 | 6783.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.382838E+10 | 5158.84 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.230627E+10 | 6549.01 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.189503E+09 | 1776.79 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 12257622.54 | 817.64 | 06-APR-06:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 53254001.91 | 1382.81 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.416050E+09 | 3117.57 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.205423E+10 | 4185.67 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.885995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.382838E+10 | 6549.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.527826E+10 | 5442.10 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.316342E+10 | 6819.46 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.405716E+09 | 2274.05 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 43343732.34 | 1177.66 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.121283E+09 | 1889.22 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.970105E+09 | 3501.91 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.327167E+10 | 4496.70 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.132538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.527826E+10 | 6819.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.325070E+10 | 3453.17 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.190262E+10 | 4408.84 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117446E+09 | 946.49 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 381180.63 | 135.04 | 07-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 11781273.59 | 650.92 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.380478E+09 | 2265.86 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.176010E+10 | 2763.47 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.742351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.325070E+10 | 4408.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.325123E+10 | 3452.45 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.190175E+10 | 4411.53 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118787E+09 | 949.06 | 22-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 387867.36 | 135.42 | 07-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 12236092.31 | 665.53 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.380602E+09 | 2264.83 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.175937E+10 | 2762.86 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.742437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.325123E+10 | 4411.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.191201E+10 | 3182.18 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.114604E+10 | 4220.53 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 19693831.37 | 494.90 | 23-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 94736842.46 | 1665.90 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.736344E+09 | 2151.75 | 17-DEC-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.390882E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.191201E+10 | 4220.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.191388E+10 | 3181.51 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.114532E+10 | 4222.38 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 19779823.59 | 496.87 | 23-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 94430216.83 | 1662.90 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.736878E+09 | 2146.28 | 17-DEC-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.391028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.191388E+10 | 4222.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.371221E+10 | 3906.91 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.244017E+10 | 5242.38 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.771776E+09 | 2183.10 | 18-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.243801E+09 | 2037.09 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22375231.31 | 738.35 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1932023.58 | 263.93 | 29-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.401308E+09 | 1842.20 | 25-OCT-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113645E+10 | 2962.10 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.253691E+10 | 3464.94 | 17-DEC-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.112669E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.371221E+10 | 5242.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.450863E+10 | 4050.01 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.294887E+10 | 5317.65 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.980130E+09 | 2328.69 | 18-MAR-07:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.300814E+09 | 2111.51 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 22772754.46 | 720.99 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 2088033.08 | 270.48 | 29-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.541005E+09 | 1985.69 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.154488E+10 | 3100.24 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.321241E+10 | 3619.27 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140616E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.450863E+10 | 5317.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.370045E+10 | 3904.24 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.241917E+10 | 5246.06 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.746987E+09 | 2170.16 | 18-MAR-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.228230E+09 | 2065.33 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 19792093.96 | 720.70 | 11-MAY-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1930826.99 | 265.12 | 29-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.389967E+09 | 1886.67 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.110899E+10 | 2954.57 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.250671E+10 | 3456.77 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.111222E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.370045E+10 | 5246.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.449939E+10 | 4047.31 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.291479E+10 | 5319.76 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.950543E+09 | 2271.00 | 18-MAR-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.281461E+09 | 2130.88 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20807832.71 | 746.15 | 11-MAY-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 2063286.45 | 270.89 | 29-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.521252E+09 | 2012.55 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.150877E+10 | 3091.95 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.318601E+10 | 3556.42 | 17-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138851E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.449939E+10 | 5319.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.322338E+10 | 2799.45 | 07-JAN-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.202711E+10 | 3778.50 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.586563E+09 | 1594.60 | 18-MAR-07:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.169241E+09 | 1473.94 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 5959541.98 | 341.67 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.284044E+09 | 1407.10 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.991227E+09 | 2232.00 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.220022E+10 | 2495.93 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.948775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.322338E+10 | 3778.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.322378E+10 | 2800.32 | 14-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.202674E+10 | 3779.38 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.588299E+09 | 1597.03 | 18-MAR-07:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.169370E+09 | 1475.83 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 6051015.02 | 345.12 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.284258E+09 | 1409.70 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.992109E+09 | 2231.61 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.220010E+10 | 2495.06 | 02-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.949070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.322378E+10 | 3779.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.244330E+10 | 2663.77 | 14-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.154377E+10 | 3698.11 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.403811E+09 | 1446.75 | 18-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.125972E+09 | 1380.64 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 5629547.62 | 347.51 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.183469E+09 | 1245.46 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.636374E+09 | 2072.02 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156490E+10 | 2284.58 | 17-DEC-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.690722E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.244330E+10 | 3698.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.244461E+10 | 2665.44 | 14-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.154387E+10 | 3699.23 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.404862E+09 | 1451.63 | 18-MAR-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.126194E+09 | 1383.76 | 06-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 5679946.95 | 351.54 | 11-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.183880E+09 | 1251.05 | 26-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.636823E+09 | 2071.36 | 22-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.156540E+10 | 2284.34 | 17-DEC-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.691132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.244461E+10 | 3699.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 28303120.79 | 28303120.79 | 649.20 | 26-FEB-17:10 | 649.20 | 0.00 |
| March | 0.00 | 0.00 | 87144184.38 | 79672307.06 | 1280.24 | 30-MAR-16:07 | 1209.52 | 0.00 |
| April | 0.00 | 0.00 | 0.374551E+09 | 0.348185E+09 | 1370.17 | 17-APR-16:05 | 1370.17 | 0.00 |
| May | 0.00 | 0.00 | 0.127130E+10 | 0.104425E+10 | 1937.19 | 19-MAY-17:30 | 1799.38 | 0.00 |
| June | 0.00 | 0.00 | 0.325080E+10 | 0.250813E+10 | 2849.76 | 25-JUN-16:02 | 2301.92 | 0.00 |
| July | 0.00 | 0.00 | 0.433680E+10 | 0.318851E+10 | 3173.71 | 15-JUL-16:40 | 2465.66 | 0.00 |
| August | 0.00 | 0.00 | 0.512279E+10 | 0.371558E+10 | 3270.16 | 19-AUG-16:10 | 2580.47 | 0.00 |
| September | 0.00 | 0.00 | 0.326725E+10 | 0.254924E+10 | 3130.23 | 07-SEP-16:10 | 2543.07 | 0.00 |
| October | 0.00 | 0.00 | 0.131415E+10 | 0.109683E+10 | 2773.52 | 10-OCT-16:02 | 2440.78 | 0.00 |
| November | 0.00 | 0.00 | 0.230512E+09 | 0.207167E+09 | 1738.46 | 05-NOV-16:05 | 1470.58 | 0.00 |
| December | 0.00 | 0.00 | 7972858.41 | 6790189.55 | 560.03 | 12-DEC-14:30 | 462.08 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.192916E+11 | 0.147727E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.512279E+10 | 0.371558E+10 | 3270.16 | 2580.47 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 25938131.32 | 22393546.24 | 887.55 | 30-MAR-16:30 | 814.94 | 0.00 |
| April | 0.00 | 0.00 | 0.199688E+09 | 0.182557E+09 | 1039.26 | 17-APR-17:05 | 1039.26 | 0.00 |
| May | 0.00 | 0.00 | 0.112360E+10 | 0.912586E+09 | 1846.09 | 19-MAY-17:30 | 1696.03 | 0.00 |
| June | 0.00 | 0.00 | 0.323346E+10 | 0.248708E+10 | 2783.46 | 06-JUN-17:03 | 2385.82 | 0.00 |
| July | 0.00 | 0.00 | 0.427762E+10 | 0.313513E+10 | 3078.94 | 15-JUL-16:50 | 2403.06 | 0.00 |
| August | 0.00 | 0.00 | 0.484888E+10 | 0.347153E+10 | 3098.80 | 03-AUG-16:30 | 2481.63 | 0.00 |
| September | 0.00 | 0.00 | 0.277248E+10 | 0.210593E+10 | 2782.81 | 07-SEP-16:30 | 2192.40 | 0.00 |
| October | 0.00 | 0.00 | 0.728624E+09 | 0.558846E+09 | 1966.09 | 10-OCT-16:02 | 1642.75 | 0.00 |
| November | 0.00 | 0.00 | 24206913.21 | 18645715.76 | 1043.59 | 05-NOV-16:10 | 835.78 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.172345E+11 | 0.128947E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.484888E+10 | 0.347153E+10 | 3098.80 | 2481.63 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 68693347.90 | 68693347.90 | 1381.53 | 28-FEB-15:00 | 1381.53 | 0.00 |
| March | 0.00 | 0.00 | 0.259575E+09 | 0.229488E+09 | 6676.03 | 31-MAR-08:62 | 5050.29 | 0.00 |
| April | 0.00 | 0.00 | 0.562982E+09 | 0.515437E+09 | 6720.34 | 19-APR-08:62 | 5598.27 | 0.00 |
| May | 0.00 | 0.00 | 0.129125E+10 | 0.107608E+10 | 7083.89 | 26-MAY-08:62 | 4434.80 | 0.00 |
| June | 0.00 | 0.00 | 0.253013E+10 | 0.201090E+10 | 7354.99 | 26-JUN-07:02 | 4435.02 | 0.00 |
| July | 0.00 | 0.00 | 0.290235E+10 | 0.223785E+10 | 7455.83 | 27-JUL-07:02 | 3801.00 | 0.00 |
| August | 0.00 | 0.00 | 0.359770E+10 | 0.272295E+10 | 7501.16 | 24-AUG-07:02 | 3836.51 | 0.00 |
| September | 0.00 | 0.00 | 0.229315E+10 | 0.188975E+10 | 7345.33 | 07-SEP-07:02 | 4450.10 | 0.00 |
| October | 0.00 | 0.00 | 0.117779E+10 | 0.100988E+10 | 7304.83 | 19-OCT-07:03 | 4012.44 | 0.00 |
| November | 0.00 | 0.00 | 0.401348E+09 | 0.377737E+09 | 4050.71 | 06-NOV-09:03 | 3869.76 | 0.00 |
| December | 0.00 | 0.00 | 75661329.10 | 62338809.83 | 4011.14 | 13-DEC-09:03 | 2969.13 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.151606E+11 | 0.122011E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.359770E+10 | 0.272295E+10 | 7501.16 | 5598.27 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 15962582.59 | 13744568.16 | 624.94 | 30-MAR-16:07 | 572.19 | 0.00 |
| April | 0.00 | 0.00 | 0.195232E+09 | 0.178344E+09 | 855.20 | 19-APR-16:07 | 781.23 | 0.00 |
| May | 0.00 | 0.00 | 0.115196E+10 | 0.934645E+09 | 1662.06 | 31-MAY-16:03 | 1298.00 | 0.00 |
| June | 0.00 | 0.00 | 0.328537E+10 | 0.253116E+10 | 2528.23 | 29-JUN-17:10 | 1911.44 | 0.00 |
| July | 0.00 | 0.00 | 0.434475E+10 | 0.318812E+10 | 2798.59 | 08-JUL-11:00 | 2133.98 | 0.00 |
| August | 0.00 | 0.00 | 0.485364E+10 | 0.347474E+10 | 2869.27 | 19-AUG-16:10 | 2237.36 | 0.00 |
| September | 0.00 | 0.00 | 0.278704E+10 | 0.211759E+10 | 2539.96 | 07-SEP-16:10 | 1988.72 | 0.00 |
| October | 0.00 | 0.00 | 0.724905E+09 | 0.552737E+09 | 1871.85 | 18-OCT-16:05 | 1203.20 | 0.00 |
| November | 0.00 | 0.00 | 18520826.57 | 13809909.07 | 824.24 | 05-NOV-16:10 | 650.29 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.173774E+11 | 0.130049E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.485364E+10 | 0.347474E+10 | 2869.27 | 2237.36 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 17444967.27 | 14896446.18 | 581.13 | 30-MAR-16:07 | 526.29 | 0.00 |
| April | 0.00 | 0.00 | 0.214139E+09 | 0.188617E+09 | 828.25 | 19-APR-16:07 | 753.56 | 0.00 |
| May | 0.00 | 0.00 | 0.111288E+10 | 0.891652E+09 | 1492.21 | 30-MAY-18:00 | 1130.73 | 0.00 |
| June | 0.00 | 0.00 | 0.289717E+10 | 0.221618E+10 | 2141.34 | 23-JUN-17:00 | 1598.85 | 0.00 |
| July | 0.00 | 0.00 | 0.377706E+10 | 0.273493E+10 | 2391.46 | 15-JUL-17:05 | 1840.62 | 0.00 |
| August | 0.00 | 0.00 | 0.418952E+10 | 0.296325E+10 | 2360.17 | 03-AUG-17:05 | 1858.87 | 0.00 |
| September | 0.00 | 0.00 | 0.248599E+10 | 0.187033E+10 | 2098.88 | 07-SEP-16:10 | 1619.17 | 0.00 |
| October | 0.00 | 0.00 | 0.684745E+09 | 0.520950E+09 | 1666.20 | 18-OCT-16:05 | 1078.48 | 0.00 |
| November | 0.00 | 0.00 | 24985685.75 | 18729601.45 | 832.36 | 05-NOV-16:10 | 658.30 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.154039E+11 | 0.114195E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.418952E+10 | 0.296325E+10 | 2391.46 | 1858.87 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 17238868.80 | 14718238.88 | 577.42 | 30-MAR-16:07 | 522.84 | 0.00 |
| April | 0.00 | 0.00 | 0.214787E+09 | 0.189306E+09 | 829.66 | 19-APR-16:07 | 754.95 | 0.00 |
| May | 0.00 | 0.00 | 0.111584E+10 | 0.894298E+09 | 1491.90 | 30-MAY-18:00 | 1130.49 | 0.00 |
| June | 0.00 | 0.00 | 0.290027E+10 | 0.221883E+10 | 2136.93 | 23-JUN-17:00 | 1595.24 | 0.00 |
| July | 0.00 | 0.00 | 0.378068E+10 | 0.273782E+10 | 2387.18 | 15-JUL-17:05 | 1837.01 | 0.00 |
| August | 0.00 | 0.00 | 0.419023E+10 | 0.296377E+10 | 2357.20 | 03-AUG-17:05 | 1856.39 | 0.00 |
| September | 0.00 | 0.00 | 0.248709E+10 | 0.187121E+10 | 2097.59 | 07-SEP-16:10 | 1618.34 | 0.00 |
| October | 0.00 | 0.00 | 0.687304E+09 | 0.523202E+09 | 1667.58 | 18-OCT-16:05 | 1079.63 | 0.00 |
| November | 0.00 | 0.00 | 24661950.69 | 18477177.88 | 827.33 | 05-NOV-16:10 | 654.04 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.154181E+11 | 0.114316E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.419023E+10 | 0.296377E+10 | 2387.18 | 1856.39 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 35468038.47 | 35468038.47 | 609.67 | 28-FEB-15:10 | 609.67 | 0.00 |
| March | 0.00 | 0.00 | 97120305.04 | 89156474.33 | 984.82 | 30-MAR-16:07 | 926.01 | 0.00 |
| April | 0.00 | 0.00 | 0.414707E+09 | 0.376282E+09 | 1108.80 | 17-APR-16:10 | 1108.80 | 0.00 |
| May | 0.00 | 0.00 | 0.128626E+10 | 0.104471E+10 | 1525.54 | 30-MAY-18:00 | 1167.66 | 0.00 |
| June | 0.00 | 0.00 | 0.292593E+10 | 0.224670E+10 | 2221.35 | 25-JUN-16:02 | 1764.76 | 0.00 |
| July | 0.00 | 0.00 | 0.385300E+10 | 0.280193E+10 | 2469.46 | 15-JUL-16:40 | 1889.64 | 0.00 |
| August | 0.00 | 0.00 | 0.448502E+10 | 0.322431E+10 | 2626.03 | 19-AUG-16:10 | 2048.40 | 0.00 |
| September | 0.00 | 0.00 | 0.300877E+10 | 0.233670E+10 | 2462.55 | 07-SEP-16:10 | 1975.25 | 0.00 |
| October | 0.00 | 0.00 | 0.134580E+10 | 0.113185E+10 | 2281.75 | 11-OCT-14:10 | 1880.44 | 0.00 |
| November | 0.00 | 0.00 | 0.328176E+09 | 0.295999E+09 | 1516.35 | 05-NOV-16:10 | 1275.66 | 0.00 |
| December | 0.00 | 0.00 | 14755244.41 | 12546246.20 | 661.52 | 12-DEC-14:00 | 544.59 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.177950E+11 | 0.135957E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.448502E+10 | 0.322431E+10 | 2626.03 | 2048.40 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 37867076.46 | 37867076.46 | 638.78 | 28-FEB-15:10 | 638.78 | 0.00 |
| March | 0.00 | 0.00 | 0.109417E+09 | 0.100440E+09 | 1022.43 | 30-MAR-16:07 | 962.50 | 0.00 |
| April | 0.00 | 0.00 | 0.461035E+09 | 0.417797E+09 | 1166.58 | 17-APR-16:05 | 1166.58 | 0.00 |
| May | 0.00 | 0.00 | 0.141886E+10 | 0.115596E+10 | 1599.33 | 30-MAY-18:00 | 1231.05 | 0.00 |
| June | 0.00 | 0.00 | 0.317296E+10 | 0.245848E+10 | 2364.64 | 25-JUN-16:02 | 1899.82 | 0.00 |
| July | 0.00 | 0.00 | 0.418443E+10 | 0.308102E+10 | 2611.02 | 15-JUL-16:50 | 2022.84 | 0.00 |
| August | 0.00 | 0.00 | 0.482851E+10 | 0.351638E+10 | 2785.08 | 19-AUG-16:10 | 2193.69 | 0.00 |
| September | 0.00 | 0.00 | 0.327506E+10 | 0.256667E+10 | 2547.76 | 07-SEP-16:10 | 2054.47 | 0.00 |
| October | 0.00 | 0.00 | 0.146422E+10 | 0.123807E+10 | 2358.81 | 11-OCT-14:10 | 1952.61 | 0.00 |
| November | 0.00 | 0.00 | 0.360722E+09 | 0.325573E+09 | 1567.96 | 05-NOV-16:10 | 1323.58 | 0.00 |
| December | 0.00 | 0.00 | 15321975.63 | 12974708.54 | 676.30 | 12-DEC-14:00 | 556.83 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.193284E+11 | 0.149112E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.482851E+10 | 0.351638E+10 | 2785.08 | 2193.69 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.248217E+09 | 0.248217E+09 | 3124.27 | 26-FEB-16:30 | 3124.27 | 0.00 |
| March | 0.00 | 0.00 | 0.101478E+10 | 0.940535E+09 | 4964.34 | 30-MAR-16:20 | 4763.03 | 0.00 |
| April | 0.00 | 0.00 | 0.266013E+10 | 0.242743E+10 | 4709.40 | 15-APR-16:10 | 4709.40 | 0.00 |
| May | 0.00 | 0.00 | 0.513146E+10 | 0.429949E+10 | 5508.70 | 06-MAY-16:03 | 4852.31 | 0.00 |
| June | 0.00 | 0.00 | 0.843560E+10 | 0.661808E+10 | 7011.67 | 25-JUN-16:02 | 5747.15 | 0.00 |
| July | 0.00 | 0.00 | 0.101979E+11 | 0.755264E+10 | 7504.44 | 15-JUL-16:30 | 5855.92 | 0.00 |
| August | 0.00 | 0.00 | 0.113107E+11 | 0.819083E+10 | 7510.67 | 01-AUG-17:10 | 6263.06 | 0.00 |
| September | 0.00 | 0.00 | 0.681062E+10 | 0.529513E+10 | 7004.19 | 07-SEP-16:10 | 5676.25 | 0.00 |
| October | 0.00 | 0.00 | 0.272570E+10 | 0.226528E+10 | 6298.14 | 10-OCT-16:03 | 5554.41 | 0.00 |
| November | 0.00 | 0.00 | 0.495426E+09 | 0.442816E+09 | 4216.30 | 05-NOV-16:10 | 3620.47 | 0.00 |
| December | 0.00 | 0.00 | 54828994.73 | 47503459.21 | 2084.49 | 12-DEC-14:30 | 1748.62 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.490853E+11 | 0.383280E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.113107E+11 | 0.819083E+10 | 7510.67 | 6263.06 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 29296878.85 | 29296878.85 | 1279.08 | 28-FEB-17:10 | 1279.08 | 0.00 |
| March | 0.00 | 0.00 | 0.440248E+09 | 0.393280E+09 | 4083.28 | 30-MAR-16:40 | 3850.86 | 0.00 |
| April | 0.00 | 0.00 | 0.199849E+10 | 0.179358E+10 | 3971.80 | 17-APR-17:05 | 3971.80 | 0.00 |
| May | 0.00 | 0.00 | 0.477525E+10 | 0.397309E+10 | 5295.15 | 19-MAY-17:30 | 4918.18 | 0.00 |
| June | 0.00 | 0.00 | 0.837661E+10 | 0.655710E+10 | 6925.21 | 06-JUN-17:05 | 5975.74 | 0.00 |
| July | 0.00 | 0.00 | 0.100402E+11 | 0.741498E+10 | 7258.13 | 15-JUL-16:40 | 5677.82 | 0.00 |
| August | 0.00 | 0.00 | 0.107052E+11 | 0.765473E+10 | 7324.95 | 01-AUG-17:00 | 6080.09 | 0.00 |
| September | 0.00 | 0.00 | 0.574552E+10 | 0.434366E+10 | 6181.86 | 07-SEP-16:30 | 4855.49 | 0.00 |
| October | 0.00 | 0.00 | 0.149020E+10 | 0.112722E+10 | 4488.04 | 10-OCT-16:02 | 3764.01 | 0.00 |
| November | 0.00 | 0.00 | 62734077.27 | 47802875.78 | 2600.03 | 05-NOV-16:10 | 2121.57 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.436638E+11 | 0.333347E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.107052E+11 | 0.765473E+10 | 7324.95 | 6080.09 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.260713E+09 | 0.260713E+09 | 2767.54 | 26-FEB-15:00 | 2767.54 | 0.00 |
| March | 0.00 | 0.00 | 0.925755E+09 | 0.853360E+09 | 4284.13 | 30-MAR-14:10 | 3924.89 | 0.00 |
| April | 0.00 | 0.00 | 0.262961E+10 | 0.240006E+10 | 4144.17 | 16-APR-14:00 | 4144.17 | 0.00 |
| May | 0.00 | 0.00 | 0.521151E+10 | 0.436591E+10 | 4985.61 | 30-MAY-15:10 | 4255.06 | 0.00 |
| June | 0.00 | 0.00 | 0.855267E+10 | 0.671776E+10 | 6368.67 | 28-JUN-15:00 | 4812.91 | 0.00 |
| July | 0.00 | 0.00 | 0.103399E+11 | 0.766218E+10 | 6774.07 | 22-JUL-11:30 | 5093.26 | 0.00 |
| August | 0.00 | 0.00 | 0.113203E+11 | 0.819593E+10 | 7024.39 | 19-AUG-12:00 | 5490.47 | 0.00 |
| September | 0.00 | 0.00 | 0.684355E+10 | 0.532102E+10 | 6727.76 | 06-SEP-13:00 | 5117.73 | 0.00 |
| October | 0.00 | 0.00 | 0.274128E+10 | 0.227706E+10 | 5868.92 | 11-OCT-14:10 | 4802.94 | 0.00 |
| November | 0.00 | 0.00 | 0.453027E+09 | 0.404519E+09 | 3603.32 | 05-NOV-15:20 | 2993.71 | 0.00 |
| December | 0.00 | 0.00 | 49444543.06 | 42176357.84 | 2011.09 | 12-DEC-14:00 | 1662.74 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.493278E+11 | 0.385007E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.113203E+11 | 0.819593E+10 | 7024.39 | 5490.47 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 24628179.78 | 24628179.78 | 1054.22 | 28-FEB-17:05 | 1054.22 | 0.00 |
| March | 0.00 | 0.00 | 0.377963E+09 | 0.333333E+09 | 3258.75 | 30-MAR-16:10 | 3089.29 | 0.00 |
| April | 0.00 | 0.00 | 0.195983E+10 | 0.175837E+10 | 3281.05 | 04-APR-16:15 | 2469.79 | 0.00 |
| May | 0.00 | 0.00 | 0.485423E+10 | 0.403884E+10 | 4746.70 | 30-MAY-15:10 | 4009.13 | 0.00 |
| June | 0.00 | 0.00 | 0.849286E+10 | 0.665773E+10 | 6338.45 | 28-JUN-15:00 | 4761.28 | 0.00 |
| July | 0.00 | 0.00 | 0.101803E+11 | 0.752453E+10 | 6438.96 | 22-JUL-11:00 | 4760.14 | 0.00 |
| August | 0.00 | 0.00 | 0.107143E+11 | 0.766036E+10 | 6572.80 | 01-AUG-17:00 | 5402.92 | 0.00 |
| September | 0.00 | 0.00 | 0.577933E+10 | 0.436927E+10 | 5606.11 | 06-SEP-12:30 | 4098.34 | 0.00 |
| October | 0.00 | 0.00 | 0.146635E+10 | 0.109799E+10 | 4128.67 | 18-OCT-16:05 | 2616.01 | 0.00 |
| November | 0.00 | 0.00 | 50261220.95 | 37646020.90 | 2001.25 | 05-NOV-16:10 | 1604.87 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.439001E+11 | 0.335027E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.107143E+11 | 0.766036E+10 | 6572.80 | 5402.92 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 21584715.71 | 21584715.71 | 969.98 | 28-FEB-17:10 | 969.98 | 0.00 |
| March | 0.00 | 0.00 | 0.384179E+09 | 0.339149E+09 | 2752.79 | 30-MAR-16:10 | 2595.24 | 0.00 |
| April | 0.00 | 0.00 | 0.181443E+10 | 0.159973E+10 | 2977.90 | 04-APR-16:15 | 2265.96 | 0.00 |
| May | 0.00 | 0.00 | 0.419383E+10 | 0.344332E+10 | 3944.49 | 30-MAY-18:00 | 3071.38 | 0.00 |
| June | 0.00 | 0.00 | 0.703058E+10 | 0.545621E+10 | 4977.62 | 23-JUN-17:00 | 3750.61 | 0.00 |
| July | 0.00 | 0.00 | 0.845669E+10 | 0.615343E+10 | 5281.03 | 15-JUL-17:05 | 4070.08 | 0.00 |
| August | 0.00 | 0.00 | 0.895415E+10 | 0.631625E+10 | 5183.89 | 01-AUG-17:00 | 4212.66 | 0.00 |
| September | 0.00 | 0.00 | 0.510051E+10 | 0.381868E+10 | 4420.93 | 07-SEP-16:10 | 3390.87 | 0.00 |
| October | 0.00 | 0.00 | 0.142469E+10 | 0.107050E+10 | 3649.03 | 18-OCT-16:05 | 2341.96 | 0.00 |
| November | 0.00 | 0.00 | 84550667.11 | 63223212.58 | 2073.39 | 05-NOV-16:05 | 1674.15 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.374652E+11 | 0.282821E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.895415E+10 | 0.631625E+10 | 5281.03 | 4212.66 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 22272302.98 | 22272302.98 | 978.62 | 28-FEB-17:10 | 978.62 | 0.00 |
| March | 0.00 | 0.00 | 0.383631E+09 | 0.338533E+09 | 2743.37 | 30-MAR-16:10 | 2586.15 | 0.00 |
| April | 0.00 | 0.00 | 0.181688E+10 | 0.160224E+10 | 2973.79 | 04-APR-16:15 | 2262.32 | 0.00 |
| May | 0.00 | 0.00 | 0.419932E+10 | 0.344829E+10 | 3943.93 | 30-MAY-18:00 | 3070.93 | 0.00 |
| June | 0.00 | 0.00 | 0.703591E+10 | 0.546080E+10 | 4967.20 | 23-JUN-17:00 | 3741.98 | 0.00 |
| July | 0.00 | 0.00 | 0.846292E+10 | 0.615841E+10 | 5269.51 | 15-JUL-17:05 | 4060.29 | 0.00 |
| August | 0.00 | 0.00 | 0.895547E+10 | 0.631728E+10 | 5178.02 | 01-AUG-17:00 | 4208.00 | 0.00 |
| September | 0.00 | 0.00 | 0.510286E+10 | 0.382059E+10 | 4418.19 | 07-SEP-16:10 | 3389.27 | 0.00 |
| October | 0.00 | 0.00 | 0.143149E+10 | 0.107660E+10 | 3650.77 | 18-OCT-16:05 | 2343.39 | 0.00 |
| November | 0.00 | 0.00 | 83806252.72 | 62651796.46 | 2062.49 | 05-NOV-16:05 | 1664.79 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.374946E+11 | 0.283077E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.895547E+10 | 0.631728E+10 | 5269.51 | 4208.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.318943E+09 | 0.318695E+09 | 2800.31 | 26-FEB-15:00 | 2800.31 | 0.00 |
| March | 0.00 | 0.00 | 0.107894E+10 | 0.100077E+10 | 3698.27 | 30-MAR-14:10 | 3375.06 | 0.00 |
| April | 0.00 | 0.00 | 0.251621E+10 | 0.227443E+10 | 3436.61 | 15-APR-16:07 | 3436.61 | 0.00 |
| May | 0.00 | 0.00 | 0.455271E+10 | 0.377531E+10 | 3997.59 | 29-MAY-16:15 | 3419.81 | 0.00 |
| June | 0.00 | 0.00 | 0.708338E+10 | 0.551556E+10 | 5133.56 | 25-JUN-16:02 | 4123.36 | 0.00 |
| July | 0.00 | 0.00 | 0.860999E+10 | 0.629116E+10 | 5487.59 | 15-JUL-16:30 | 4209.19 | 0.00 |
| August | 0.00 | 0.00 | 0.955954E+10 | 0.685437E+10 | 5694.21 | 19-AUG-16:10 | 4429.54 | 0.00 |
| September | 0.00 | 0.00 | 0.617924E+10 | 0.478452E+10 | 5325.69 | 06-SEP-13:00 | 4010.22 | 0.00 |
| October | 0.00 | 0.00 | 0.279731E+10 | 0.234524E+10 | 5100.24 | 11-OCT-14:10 | 4202.24 | 0.00 |
| November | 0.00 | 0.00 | 0.764581E+09 | 0.687208E+09 | 3592.47 | 05-NOV-16:10 | 3067.22 | 0.00 |
| December | 0.00 | 0.00 | 0.114502E+09 | 99567440.42 | 2436.50 | 12-DEC-14:00 | 2044.33 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.435754E+11 | 0.339468E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.955954E+10 | 0.685437E+10 | 5694.21 | 4429.54 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.323381E+09 | 0.323115E+09 | 2829.84 | 26-FEB-15:00 | 2829.84 | 0.00 |
| March | 0.00 | 0.00 | 0.108157E+10 | 0.100322E+10 | 3699.60 | 30-MAR-14:10 | 3376.41 | 0.00 |
| April | 0.00 | 0.00 | 0.251936E+10 | 0.227760E+10 | 3431.51 | 15-APR-16:07 | 3431.51 | 0.00 |
| May | 0.00 | 0.00 | 0.455815E+10 | 0.378024E+10 | 3995.13 | 30-MAY-18:00 | 3132.20 | 0.00 |
| June | 0.00 | 0.00 | 0.708889E+10 | 0.552033E+10 | 5127.63 | 25-JUN-16:02 | 4118.65 | 0.00 |
| July | 0.00 | 0.00 | 0.861625E+10 | 0.629618E+10 | 5479.65 | 15-JUL-16:30 | 4202.69 | 0.00 |
| August | 0.00 | 0.00 | 0.956084E+10 | 0.685539E+10 | 5691.54 | 19-AUG-16:10 | 4427.41 | 0.00 |
| September | 0.00 | 0.00 | 0.618122E+10 | 0.478615E+10 | 5338.10 | 06-SEP-13:00 | 4021.82 | 0.00 |
| October | 0.00 | 0.00 | 0.280171E+10 | 0.234942E+10 | 5106.26 | 11-OCT-14:10 | 4208.26 | 0.00 |
| November | 0.00 | 0.00 | 0.765652E+09 | 0.688428E+09 | 3582.04 | 05-NOV-16:10 | 3057.69 | 0.00 |
| December | 0.00 | 0.00 | 0.114982E+09 | 0.100016E+09 | 2437.93 | 12-DEC-14:00 | 2045.51 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.436120E+11 | 0.339801E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.956084E+10 | 0.685539E+10 | 5691.54 | 4427.41 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 3356976.86 | 3356976.86 | 427.64 | 29-JAN-15:00 | 427.64 | 0.00 |
| February | 0.00 | 0.00 | 0.162884E+09 | 0.162884E+09 | 2369.69 | 26-FEB-16:30 | 2369.69 | 0.00 |
| March | 0.00 | 0.00 | 0.540802E+09 | 0.506097E+09 | 3272.20 | 30-MAR-16:20 | 3149.68 | 0.00 |
| April | 0.00 | 0.00 | 0.131696E+10 | 0.122297E+10 | 3094.66 | 17-APR-16:10 | 3094.66 | 0.00 |
| May | 0.00 | 0.00 | 0.261110E+10 | 0.222735E+10 | 3664.19 | 06-MAY-16:03 | 3275.94 | 0.00 |
| June | 0.00 | 0.00 | 0.460865E+10 | 0.366280E+10 | 4633.77 | 25-JUN-16:02 | 3900.79 | 0.00 |
| July | 0.00 | 0.00 | 0.560591E+10 | 0.423419E+10 | 4897.19 | 15-JUL-16:40 | 3930.86 | 0.00 |
| August | 0.00 | 0.00 | 0.623116E+10 | 0.458211E+10 | 5035.35 | 01-AUG-17:10 | 4282.64 | 0.00 |
| September | 0.00 | 0.00 | 0.336801E+10 | 0.264190E+10 | 4586.80 | 07-SEP-16:10 | 3804.28 | 0.00 |
| October | 0.00 | 0.00 | 0.123635E+10 | 0.103012E+10 | 3926.20 | 10-OCT-16:02 | 3502.81 | 0.00 |
| November | 0.00 | 0.00 | 0.262808E+09 | 0.241762E+09 | 2516.82 | 05-NOV-16:10 | 2185.19 | 0.00 |
| December | 0.00 | 0.00 | 41496254.77 | 38181586.05 | 1280.68 | 12-DEC-14:30 | 1074.63 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.259895E+11 | 0.205537E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 3356976.86 | 3356976.86 | 427.64 | 427.64 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.623116E+10 | 0.458211E+10 | 5035.35 | 4282.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 36112122.71 | 36112122.71 | 917.15 | 26-FEB-17:10 | 917.15 | 0.00 |
| March | 0.00 | 0.00 | 0.260289E+09 | 0.234141E+09 | 2718.77 | 30-MAR-16:40 | 2575.03 | 0.00 |
| April | 0.00 | 0.00 | 0.100027E+10 | 0.916334E+09 | 2589.96 | 17-APR-17:05 | 2589.96 | 0.00 |
| May | 0.00 | 0.00 | 0.242172E+10 | 0.204955E+10 | 3509.66 | 19-MAY-17:30 | 3285.37 | 0.00 |
| June | 0.00 | 0.00 | 0.457093E+10 | 0.361995E+10 | 4545.92 | 06-JUN-17:03 | 3972.30 | 0.00 |
| July | 0.00 | 0.00 | 0.552535E+10 | 0.415767E+10 | 4757.99 | 15-JUL-16:40 | 3818.65 | 0.00 |
| August | 0.00 | 0.00 | 0.590526E+10 | 0.428547E+10 | 4900.71 | 01-AUG-17:00 | 4163.53 | 0.00 |
| September | 0.00 | 0.00 | 0.280897E+10 | 0.213605E+10 | 4054.10 | 07-SEP-16:13 | 3269.49 | 0.00 |
| October | 0.00 | 0.00 | 0.675769E+09 | 0.510403E+09 | 2791.44 | 10-OCT-16:13 | 2376.81 | 0.00 |
| November | 0.00 | 0.00 | 36800405.34 | 28795982.90 | 1457.85 | 05-NOV-16:10 | 1190.21 | 0.00 |
| December | 0.00 | 0.00 | 583066.32 | 500124.63 | 143.59 | 12-DEC-17:10 | 123.25 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.232421E+11 | 0.179750E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.590526E+10 | 0.428547E+10 | 4900.71 | 4163.53 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 2697997.17 | 2697997.17 | 455.38 | 29-JAN-15:00 | 455.38 | 0.00 |
| February | 0.00 | 0.00 | 0.156615E+09 | 0.156615E+09 | 2053.15 | 26-FEB-15:00 | 2053.15 | 0.00 |
| March | 0.00 | 0.00 | 0.466344E+09 | 0.432992E+09 | 2902.42 | 30-MAR-14:10 | 2687.19 | 0.00 |
| April | 0.00 | 0.00 | 0.127696E+10 | 0.118456E+10 | 2770.10 | 16-APR-14:00 | 2770.10 | 0.00 |
| May | 0.00 | 0.00 | 0.263575E+10 | 0.224344E+10 | 3385.49 | 30-MAY-15:10 | 2941.55 | 0.00 |
| June | 0.00 | 0.00 | 0.466981E+10 | 0.371145E+10 | 4205.11 | 06-JUN-14:10 | 3594.55 | 0.00 |
| July | 0.00 | 0.00 | 0.568458E+10 | 0.428993E+10 | 4455.36 | 08-JUL-13:00 | 3727.78 | 0.00 |
| August | 0.00 | 0.00 | 0.623513E+10 | 0.458067E+10 | 4650.93 | 19-AUG-14:00 | 3865.63 | 0.00 |
| September | 0.00 | 0.00 | 0.338209E+10 | 0.265034E+10 | 4496.14 | 06-SEP-13:00 | 3502.45 | 0.00 |
| October | 0.00 | 0.00 | 0.120232E+10 | 0.994445E+09 | 3686.75 | 11-OCT-14:10 | 3046.09 | 0.00 |
| November | 0.00 | 0.00 | 0.224805E+09 | 0.205901E+09 | 2117.90 | 05-NOV-15:30 | 1780.40 | 0.00 |
| December | 0.00 | 0.00 | 32448358.60 | 29361156.80 | 1218.77 | 12-DEC-14:10 | 1010.93 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.259695E+11 | 0.204824E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 2697997.17 | 2697997.17 | 455.38 | 455.38 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.623513E+10 | 0.458067E+10 | 4650.93 | 3865.63 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 26997427.15 | 26997427.15 | 697.37 | 28-FEB-15:00 | 697.37 | 0.00 |
| March | 0.00 | 0.00 | 0.218629E+09 | 0.193829E+09 | 2160.37 | 30-MAR-16:10 | 2059.24 | 0.00 |
| April | 0.00 | 0.00 | 0.954998E+09 | 0.872422E+09 | 2093.83 | 19-APR-15:10 | 1920.83 | 0.00 |
| May | 0.00 | 0.00 | 0.244720E+10 | 0.206575E+10 | 3204.20 | 30-MAY-15:10 | 2756.27 | 0.00 |
| June | 0.00 | 0.00 | 0.463316E+10 | 0.367012E+10 | 4076.16 | 28-JUN-15:00 | 3112.99 | 0.00 |
| July | 0.00 | 0.00 | 0.560395E+10 | 0.421391E+10 | 4262.42 | 07-JUL-13:00 | 3363.84 | 0.00 |
| August | 0.00 | 0.00 | 0.591023E+10 | 0.428464E+10 | 4316.68 | 01-AUG-17:00 | 3625.02 | 0.00 |
| September | 0.00 | 0.00 | 0.282185E+10 | 0.214183E+10 | 3716.36 | 06-SEP-13:00 | 2791.73 | 0.00 |
| October | 0.00 | 0.00 | 0.637505E+09 | 0.471152E+09 | 2423.66 | 18-OCT-16:05 | 1549.72 | 0.00 |
| November | 0.00 | 0.00 | 25775506.06 | 19843082.47 | 1041.53 | 05-NOV-16:10 | 831.50 | 0.00 |
| December | 0.00 | 0.00 | 156662.71 | 134539.16 | 82.24 | 12-DEC-17:10 | 70.49 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.232804E+11 | 0.179606E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.591023E+10 | 0.428464E+10 | 4316.68 | 3625.02 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 16954918.06 | 16954918.06 | 543.83 | 28-FEB-17:10 | 543.83 | 0.00 |
| March | 0.00 | 0.00 | 0.187606E+09 | 0.165511E+09 | 1830.17 | 30-MAR-16:10 | 1739.93 | 0.00 |
| April | 0.00 | 0.00 | 0.789579E+09 | 0.710022E+09 | 1761.71 | 19-APR-15:10 | 1611.39 | 0.00 |
| May | 0.00 | 0.00 | 0.203211E+10 | 0.169465E+10 | 2567.59 | 30-MAY-15:10 | 2195.29 | 0.00 |
| June | 0.00 | 0.00 | 0.383947E+10 | 0.301686E+10 | 3239.54 | 23-JUN-17:00 | 2522.07 | 0.00 |
| July | 0.00 | 0.00 | 0.467510E+10 | 0.347710E+10 | 3471.91 | 15-JUL-16:50 | 2759.73 | 0.00 |
| August | 0.00 | 0.00 | 0.496511E+10 | 0.356947E+10 | 3494.18 | 01-AUG-17:00 | 2931.76 | 0.00 |
| September | 0.00 | 0.00 | 0.243282E+10 | 0.182352E+10 | 2914.86 | 07-SEP-16:10 | 2312.97 | 0.00 |
| October | 0.00 | 0.00 | 0.555830E+09 | 0.403981E+09 | 2104.35 | 18-OCT-16:03 | 1368.59 | 0.00 |
| November | 0.00 | 0.00 | 28217470.71 | 21547638.38 | 1020.82 | 05-NOV-16:10 | 814.27 | 0.00 |
| December | 0.00 | 0.00 | 165035.50 | 141036.91 | 93.84 | 12-DEC-17:05 | 80.21 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.195230E+11 | 0.148998E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.496511E+10 | 0.356947E+10 | 3494.18 | 2931.76 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 17201438.87 | 17201438.87 | 540.64 | 28-FEB-17:10 | 540.64 | 0.00 |
| March | 0.00 | 0.00 | 0.187436E+09 | 0.165291E+09 | 1821.03 | 30-MAR-16:10 | 1731.00 | 0.00 |
| April | 0.00 | 0.00 | 0.792139E+09 | 0.712515E+09 | 1760.37 | 19-APR-15:10 | 1610.28 | 0.00 |
| May | 0.00 | 0.00 | 0.203694E+10 | 0.169888E+10 | 2570.04 | 30-MAY-15:10 | 2198.07 | 0.00 |
| June | 0.00 | 0.00 | 0.384384E+10 | 0.302061E+10 | 3228.18 | 23-JUN-17:00 | 2512.24 | 0.00 |
| July | 0.00 | 0.00 | 0.467911E+10 | 0.348014E+10 | 3460.70 | 15-JUL-16:40 | 2745.52 | 0.00 |
| August | 0.00 | 0.00 | 0.496617E+10 | 0.357017E+10 | 3483.82 | 01-AUG-17:00 | 2922.51 | 0.00 |
| September | 0.00 | 0.00 | 0.243548E+10 | 0.182570E+10 | 2908.45 | 07-SEP-16:10 | 2307.79 | 0.00 |
| October | 0.00 | 0.00 | 0.557587E+09 | 0.405396E+09 | 2104.43 | 18-OCT-16:03 | 1368.60 | 0.00 |
| November | 0.00 | 0.00 | 27990790.36 | 21368998.92 | 1009.94 | 05-NOV-16:10 | 805.11 | 0.00 |
| December | 0.00 | 0.00 | 152907.72 | 130617.11 | 91.05 | 12-DEC-17:05 | 77.81 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.195440E+11 | 0.149174E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.496617E+10 | 0.357017E+10 | 3483.82 | 2922.51 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 4843597.05 | 4843597.05 | 521.51 | 29-JAN-15:00 | 521.51 | 0.00 |
| February | 0.00 | 0.00 | 0.142216E+09 | 0.142216E+09 | 1830.79 | 26-FEB-15:10 | 1830.79 | 0.00 |
| March | 0.00 | 0.00 | 0.441139E+09 | 0.409810E+09 | 2510.64 | 30-MAR-14:10 | 2316.47 | 0.00 |
| April | 0.00 | 0.00 | 0.110825E+10 | 0.101744E+10 | 2289.60 | 16-APR-14:00 | 2289.60 | 0.00 |
| May | 0.00 | 0.00 | 0.222498E+10 | 0.187505E+10 | 2746.89 | 30-MAY-15:10 | 2379.00 | 0.00 |
| June | 0.00 | 0.00 | 0.387676E+10 | 0.305887E+10 | 3425.78 | 25-JUN-16:02 | 2849.63 | 0.00 |
| July | 0.00 | 0.00 | 0.475761E+10 | 0.355443E+10 | 3644.96 | 08-JUL-16:03 | 3142.91 | 0.00 |
| August | 0.00 | 0.00 | 0.529384E+10 | 0.386838E+10 | 3748.32 | 19-AUG-16:10 | 3009.02 | 0.00 |
| September | 0.00 | 0.00 | 0.300339E+10 | 0.233928E+10 | 3596.90 | 06-SEP-13:30 | 2821.57 | 0.00 |
| October | 0.00 | 0.00 | 0.112522E+10 | 0.930124E+09 | 3224.24 | 11-OCT-14:10 | 2690.67 | 0.00 |
| November | 0.00 | 0.00 | 0.249883E+09 | 0.227231E+09 | 2094.26 | 05-NOV-15:30 | 1768.94 | 0.00 |
| December | 0.00 | 0.00 | 44577933.87 | 40898443.33 | 1250.97 | 12-DEC-14:20 | 1048.40 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.222727E+11 | 0.174686E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 4843597.05 | 4843597.05 | 521.51 | 521.51 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.529384E+10 | 0.386838E+10 | 3748.32 | 3142.91 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 5165465.78 | 5165465.78 | 537.96 | 29-JAN-15:00 | 537.96 | 0.00 |
| February | 0.00 | 0.00 | 0.143877E+09 | 0.143877E+09 | 1841.61 | 26-FEB-15:10 | 1841.61 | 0.00 |
| March | 0.00 | 0.00 | 0.442405E+09 | 0.411025E+09 | 2514.48 | 30-MAR-14:10 | 2320.32 | 0.00 |
| April | 0.00 | 0.00 | 0.111133E+10 | 0.102048E+10 | 2302.48 | 16-APR-14:00 | 2302.48 | 0.00 |
| May | 0.00 | 0.00 | 0.222990E+10 | 0.187938E+10 | 2749.44 | 30-MAY-15:10 | 2381.83 | 0.00 |
| June | 0.00 | 0.00 | 0.388129E+10 | 0.306278E+10 | 3418.12 | 25-JUN-16:02 | 2843.01 | 0.00 |
| July | 0.00 | 0.00 | 0.476167E+10 | 0.355753E+10 | 3638.91 | 08-JUL-16:03 | 3137.55 | 0.00 |
| August | 0.00 | 0.00 | 0.529488E+10 | 0.386907E+10 | 3752.48 | 19-AUG-14:00 | 3106.44 | 0.00 |
| September | 0.00 | 0.00 | 0.300573E+10 | 0.234123E+10 | 3608.66 | 06-SEP-13:30 | 2833.09 | 0.00 |
| October | 0.00 | 0.00 | 0.112914E+10 | 0.933754E+09 | 3230.97 | 10-OCT-14:10 | 2816.64 | 0.00 |
| November | 0.00 | 0.00 | 0.251093E+09 | 0.228496E+09 | 2086.19 | 05-NOV-15:30 | 1761.69 | 0.00 |
| December | 0.00 | 0.00 | 44976144.99 | 41278125.39 | 1254.05 | 12-DEC-14:10 | 1044.88 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.223015E+11 | 0.174941E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 5165465.78 | 5165465.78 | 537.96 | 537.96 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.529488E+10 | 0.386907E+10 | 3752.48 | 3137.55 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.101916E+09 | 0.85 | 108.24 | 07-JAN-10:00 | 0.96 |
| February | 70059544.45 | 0.73 | 138.49 | 12-FEB-06:00 | 0.96 |
| March | 20783014.26 | 0.35 | 93.71 | 30-MAR-16:07 | 1.07 |
| April | 31151655.60 | 0.37 | 102.52 | 17-APR-16:08 | 1.07 |
| May | 90475110.14 | 0.67 | 140.45 | 19-MAY-17:30 | 1.05 |
| June | 0.226865E+09 | 1.02 | 199.42 | 25-JUN-16:02 | 1.02 |
| July | 0.298395E+09 | 1.05 | 221.33 | 08-JUL-16:03 | 1.01 |
| August | 0.349143E+09 | 1.05 | 226.00 | 18-AUG-17:20 | 1.01 |
| September | 0.226164E+09 | 1.00 | 215.48 | 07-SEP-16:10 | 1.02 |
| October | 92779241.79 | 0.58 | 194.11 | 10-OCT-16:03 | 1.03 |
| November | 22765004.68 | 0.33 | 121.16 | 05-NOV-16:05 | 1.06 |
| December | 44752465.04 | 0.61 | 73.46 | 17-DEC-04:50 | 0.95 |
| Annual Sum or Average | 0.157525E+10 | 0.72 | |||
| Minimum of Months | 20783014.26 | 0.33 | 73.46 | 0.95 | |
| Maximum of Months | 0.349143E+09 | 1.05 | 226.00 | 1.07 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.65 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.134575E+09 | 0.92 | 115.35 | 07-JAN-10:00 | 0.96 |
| February | 90493087.48 | 0.79 | 143.61 | 12-FEB-06:00 | 0.96 |
| March | 29324211.43 | 0.50 | 65.05 | 30-MAR-16:30 | 1.08 |
| April | 20755165.40 | 0.33 | 77.89 | 17-APR-17:00 | 1.08 |
| May | 79829204.13 | 0.64 | 133.55 | 19-MAY-17:30 | 1.05 |
| June | 0.225140E+09 | 1.02 | 197.93 | 06-JUN-17:03 | 1.02 |
| July | 0.293745E+09 | 1.05 | 212.07 | 15-JUL-16:50 | 1.01 |
| August | 0.329969E+09 | 1.05 | 218.24 | 01-AUG-17:00 | 1.01 |
| September | 0.191772E+09 | 0.99 | 191.22 | 07-SEP-16:17 | 1.02 |
| October | 51602393.60 | 0.44 | 138.75 | 10-OCT-16:02 | 1.05 |
| November | 17381683.18 | 0.32 | 73.21 | 05-NOV-16:10 | 1.08 |
| December | 71130884.35 | 0.82 | 84.05 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.153572E+10 | 0.74 | |||
| Minimum of Months | 17381683.18 | 0.32 | 65.05 | 0.96 | |
| Maximum of Months | 0.329969E+09 | 1.05 | 218.24 | 1.08 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.110846E+10 | 0.95 | 413.85 | 01-JAN-00:10 | 0.95 |
| February | 0.100119E+10 | 0.95 | 413.85 | 01-FEB-00:10 | 0.95 |
| March | 0.110846E+10 | 0.95 | 413.85 | 01-MAR-00:10 | 0.95 |
| April | 0.107270E+10 | 0.95 | 413.85 | 01-APR-00:10 | 0.95 |
| May | 0.110846E+10 | 0.94 | 413.85 | 01-MAY-00:10 | 0.94 |
| June | 0.107270E+10 | 0.94 | 413.85 | 01-JUN-00:10 | 0.94 |
| July | 0.110846E+10 | 0.94 | 413.85 | 01-JUL-00:10 | 0.93 |
| August | 0.110846E+10 | 0.94 | 413.85 | 01-AUG-00:10 | 0.93 |
| September | 0.107270E+10 | 0.94 | 413.85 | 01-SEP-00:10 | 0.94 |
| October | 0.110846E+10 | 0.95 | 413.85 | 01-OCT-00:10 | 0.94 |
| November | 0.107270E+10 | 0.95 | 413.85 | 01-NOV-00:10 | 0.95 |
| December | 0.110846E+10 | 0.95 | 413.85 | 01-DEC-00:10 | 0.95 |
| Annual Sum or Average | 0.130512E+11 | 0.95 | |||
| Minimum of Months | 0.100119E+10 | 0.94 | 413.85 | 0.93 | |
| Maximum of Months | 0.110846E+10 | 0.95 | 413.85 | 0.95 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.133423E+09 | 0.92 | 114.14 | 07-JAN-10:00 | 0.96 |
| February | 88765407.73 | 0.78 | 143.12 | 12-FEB-06:00 | 0.96 |
| March | 28039554.18 | 0.51 | 56.08 | 18-MAR-06:50 | 0.96 |
| April | 19990156.71 | 0.33 | 61.47 | 19-APR-16:07 | 1.08 |
| May | 80527950.27 | 0.65 | 114.92 | 30-MAY-15:10 | 1.05 |
| June | 0.224895E+09 | 1.02 | 176.66 | 06-JUN-17:00 | 1.03 |
| July | 0.293041E+09 | 1.05 | 193.85 | 08-JUL-16:01 | 1.02 |
| August | 0.324569E+09 | 1.05 | 196.72 | 01-AUG-17:00 | 1.02 |
| September | 0.189613E+09 | 0.99 | 172.51 | 07-SEP-16:10 | 1.03 |
| October | 50568229.17 | 0.46 | 122.11 | 18-OCT-16:05 | 1.05 |
| November | 16388408.37 | 0.30 | 63.36 | 22-NOV-06:00 | 0.96 |
| December | 69762557.84 | 0.83 | 80.36 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.151958E+10 | 0.74 | |||
| Minimum of Months | 16388408.37 | 0.30 | 56.08 | 0.95 | |
| Maximum of Months | 0.324569E+09 | 1.05 | 196.72 | 1.08 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 89797534.94 | 0.90 | 76.75 | 07-JAN-10:00 | 0.96 |
| February | 57447998.55 | 0.71 | 96.85 | 12-FEB-06:00 | 0.96 |
| March | 13934498.56 | 0.36 | 42.15 | 30-MAR-16:07 | 1.09 |
| April | 17013109.54 | 0.30 | 59.35 | 19-APR-16:07 | 1.08 |
| May | 77669493.28 | 0.76 | 101.41 | 30-MAY-18:00 | 1.05 |
| June | 0.198483E+09 | 1.04 | 146.44 | 06-JUN-17:03 | 1.03 |
| July | 0.254942E+09 | 1.06 | 162.99 | 15-JUL-17:05 | 1.02 |
| August | 0.280351E+09 | 1.05 | 162.23 | 03-AUG-17:05 | 1.02 |
| September | 0.169149E+09 | 1.02 | 142.98 | 07-SEP-16:10 | 1.03 |
| October | 47097086.10 | 0.48 | 108.86 | 18-OCT-16:05 | 1.05 |
| November | 8453106.35 | 0.21 | 57.51 | 05-NOV-16:10 | 1.08 |
| December | 42234929.99 | 0.75 | 53.71 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.125657E+10 | 0.72 | |||
| Minimum of Months | 8453106.35 | 0.21 | 42.15 | 0.96 | |
| Maximum of Months | 0.280351E+09 | 1.06 | 162.99 | 1.09 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.65 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 89792493.54 | 0.90 | 76.71 | 07-JAN-10:00 | 0.96 |
| February | 57409989.52 | 0.71 | 96.87 | 12-FEB-06:00 | 0.96 |
| March | 13960523.88 | 0.36 | 41.88 | 30-MAR-16:07 | 1.09 |
| April | 17072657.63 | 0.30 | 59.44 | 19-APR-16:07 | 1.08 |
| May | 77856283.12 | 0.76 | 101.36 | 30-MAY-18:00 | 1.05 |
| June | 0.198636E+09 | 1.04 | 146.25 | 06-JUN-17:03 | 1.03 |
| July | 0.255103E+09 | 1.06 | 162.66 | 15-JUL-17:05 | 1.02 |
| August | 0.280312E+09 | 1.05 | 161.99 | 03-AUG-17:05 | 1.02 |
| September | 0.169173E+09 | 1.02 | 142.85 | 07-SEP-16:10 | 1.03 |
| October | 47264866.99 | 0.48 | 108.92 | 18-OCT-16:05 | 1.05 |
| November | 8425151.22 | 0.21 | 57.15 | 05-NOV-16:10 | 1.08 |
| December | 42206457.04 | 0.75 | 53.68 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.125721E+10 | 0.72 | |||
| Minimum of Months | 8425151.22 | 0.21 | 41.88 | 0.96 | |
| Maximum of Months | 0.280312E+09 | 1.06 | 162.66 | 1.09 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.65 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 59680953.82 | 0.76 | 69.45 | 07-JAN-10:00 | 0.96 |
| February | 40027241.44 | 0.60 | 91.65 | 12-FEB-06:00 | 0.96 |
| March | 11263249.82 | 0.23 | 71.24 | 30-MAR-16:07 | 1.08 |
| April | 30443860.91 | 0.40 | 81.95 | 17-APR-16:10 | 1.07 |
| May | 89970394.67 | 0.80 | 106.25 | 29-MAY-17:07 | 1.06 |
| June | 0.201060E+09 | 1.04 | 153.77 | 25-JUN-16:02 | 1.03 |
| July | 0.260788E+09 | 1.06 | 172.89 | 08-JUL-16:03 | 1.02 |
| August | 0.300835E+09 | 1.05 | 177.92 | 19-AUG-16:10 | 1.02 |
| September | 0.204989E+09 | 1.03 | 167.82 | 07-SEP-16:10 | 1.02 |
| October | 93749616.32 | 0.72 | 156.77 | 10-OCT-16:03 | 1.03 |
| November | 24758767.53 | 0.39 | 103.98 | 05-NOV-16:10 | 1.06 |
| December | 19030083.57 | 0.44 | 46.35 | 12-DEC-14:00 | 1.09 |
| Annual Sum or Average | 0.133660E+10 | 0.71 | |||
| Minimum of Months | 11263249.82 | 0.23 | 46.35 | 0.96 | |
| Maximum of Months | 0.300835E+09 | 1.06 | 177.92 | 1.09 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.65 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 66486125.08 | 0.79 | 74.29 | 07-JAN-10:00 | 0.96 |
| February | 43760632.05 | 0.62 | 97.16 | 12-FEB-06:00 | 0.96 |
| March | 12135128.27 | 0.24 | 74.02 | 30-MAR-16:07 | 1.08 |
| April | 33686744.52 | 0.43 | 86.19 | 17-APR-16:05 | 1.07 |
| May | 99305891.16 | 0.84 | 111.20 | 29-MAY-16:40 | 1.05 |
| June | 0.218150E+09 | 1.05 | 163.67 | 25-JUN-16:02 | 1.03 |
| July | 0.283303E+09 | 1.05 | 183.37 | 08-JUL-16:01 | 1.02 |
| August | 0.323965E+09 | 1.05 | 188.55 | 19-AUG-16:10 | 1.01 |
| September | 0.223225E+09 | 1.04 | 173.71 | 07-SEP-16:10 | 1.02 |
| October | 0.102142E+09 | 0.75 | 161.87 | 10-OCT-16:03 | 1.03 |
| November | 27094440.49 | 0.40 | 107.61 | 05-NOV-16:10 | 1.06 |
| December | 20772919.12 | 0.46 | 47.44 | 12-DEC-14:00 | 1.09 |
| Annual Sum or Average | 0.145403E+10 | 0.73 | |||
| Minimum of Months | 12135128.27 | 0.24 | 47.44 | 0.96 | |
| Maximum of Months | 0.323965E+09 | 1.05 | 188.55 | 1.09 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.65 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.178883E+09 | 0.74 | 241.06 | 07-JAN-10:00 | 0.96 |
| February | 0.127587E+09 | 0.57 | 303.94 | 12-FEB-06:00 | 0.96 |
| March | 84398362.45 | 0.38 | 362.23 | 30-MAR-16:20 | 1.05 |
| April | 0.196664E+09 | 0.66 | 352.97 | 15-APR-16:03 | 1.05 |
| May | 0.369614E+09 | 0.93 | 402.08 | 19-MAY-17:30 | 1.04 |
| June | 0.598714E+09 | 1.04 | 501.71 | 06-JUN-17:05 | 1.02 |
| July | 0.714623E+09 | 1.06 | 525.89 | 15-JUL-16:30 | 1.02 |
| August | 0.785936E+09 | 1.05 | 540.24 | 01-AUG-17:00 | 1.01 |
| September | 0.480622E+09 | 0.98 | 492.24 | 07-SEP-16:10 | 1.02 |
| October | 0.197958E+09 | 0.55 | 449.75 | 10-OCT-16:03 | 1.03 |
| November | 57191389.95 | 0.34 | 299.24 | 05-NOV-16:10 | 1.06 |
| December | 0.101697E+09 | 0.58 | 196.41 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.389389E+10 | 0.74 | |||
| Minimum of Months | 57191389.95 | 0.34 | 196.41 | 0.95 | |
| Maximum of Months | 0.785936E+09 | 1.06 | 540.24 | 1.06 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.246155E+09 | 0.88 | 253.81 | 07-JAN-10:00 | 0.96 |
| February | 0.151336E+09 | 0.63 | 315.86 | 12-FEB-06:00 | 0.96 |
| March | 52062727.88 | 0.33 | 298.85 | 30-MAR-16:30 | 1.06 |
| April | 0.149215E+09 | 0.60 | 297.01 | 17-APR-17:05 | 1.06 |
| May | 0.343596E+09 | 0.92 | 386.30 | 19-MAY-17:30 | 1.04 |
| June | 0.593417E+09 | 1.04 | 499.74 | 06-JUN-17:05 | 1.02 |
| July | 0.702456E+09 | 1.06 | 508.98 | 15-JUL-16:40 | 1.02 |
| August | 0.742892E+09 | 1.06 | 525.95 | 01-AUG-17:00 | 1.01 |
| September | 0.405122E+09 | 0.97 | 434.13 | 07-SEP-16:13 | 1.03 |
| October | 0.111464E+09 | 0.46 | 322.92 | 10-OCT-16:02 | 1.05 |
| November | 50920047.11 | 0.37 | 185.77 | 05-NOV-16:10 | 1.08 |
| December | 0.154226E+09 | 0.78 | 210.12 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.370286E+10 | 0.76 | |||
| Minimum of Months | 50920047.11 | 0.33 | 185.77 | 0.95 | |
| Maximum of Months | 0.742892E+09 | 1.06 | 525.95 | 1.08 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.177233E+09 | 0.74 | 238.83 | 07-JAN-10:00 | 0.96 |
| February | 0.126676E+09 | 0.57 | 303.18 | 12-FEB-06:00 | 0.96 |
| March | 76660709.86 | 0.38 | 306.87 | 30-MAR-14:10 | 1.05 |
| April | 0.191454E+09 | 0.67 | 306.77 | 16-APR-14:00 | 1.06 |
| May | 0.369254E+09 | 0.94 | 352.87 | 30-MAY-15:10 | 1.04 |
| June | 0.596690E+09 | 1.04 | 449.12 | 06-JUN-15:10 | 1.02 |
| July | 0.711658E+09 | 1.05 | 472.27 | 08-JUL-16:03 | 1.02 |
| August | 0.772973E+09 | 1.05 | 489.55 | 19-AUG-14:00 | 1.01 |
| September | 0.474915E+09 | 0.98 | 458.21 | 06-SEP-13:00 | 1.02 |
| October | 0.196210E+09 | 0.57 | 403.04 | 10-OCT-14:00 | 1.03 |
| November | 52640414.87 | 0.35 | 251.71 | 05-NOV-15:30 | 1.06 |
| December | 98682319.39 | 0.58 | 193.77 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.384505E+10 | 0.75 | |||
| Minimum of Months | 52640414.87 | 0.35 | 193.77 | 0.95 | |
| Maximum of Months | 0.772973E+09 | 1.05 | 489.55 | 1.06 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.243921E+09 | 0.88 | 251.49 | 07-JAN-10:00 | 0.96 |
| February | 0.148084E+09 | 0.62 | 315.14 | 12-FEB-06:00 | 0.96 |
| March | 46123749.60 | 0.31 | 237.46 | 30-MAR-16:10 | 1.07 |
| April | 0.144051E+09 | 0.59 | 235.47 | 17-APR-16:08 | 1.07 |
| May | 0.343546E+09 | 0.93 | 335.35 | 30-MAY-15:10 | 1.04 |
| June | 0.591243E+09 | 1.04 | 438.97 | 06-JUN-17:00 | 1.02 |
| July | 0.699360E+09 | 1.05 | 445.58 | 15-JUL-16:50 | 1.02 |
| August | 0.730569E+09 | 1.05 | 465.57 | 01-AUG-17:00 | 1.02 |
| September | 0.400858E+09 | 0.97 | 382.58 | 06-SEP-12:40 | 1.03 |
| October | 0.107861E+09 | 0.47 | 274.11 | 18-OCT-16:05 | 1.05 |
| November | 48366579.65 | 0.36 | 161.83 | 22-NOV-06:00 | 0.96 |
| December | 0.151191E+09 | 0.79 | 207.80 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.365518E+10 | 0.76 | |||
| Minimum of Months | 46123749.60 | 0.31 | 161.83 | 0.95 | |
| Maximum of Months | 0.730569E+09 | 1.05 | 465.57 | 1.07 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.148658E+09 | 0.83 | 157.92 | 07-JAN-10:00 | 0.96 |
| February | 88670857.38 | 0.54 | 201.62 | 12-FEB-06:00 | 0.96 |
| March | 33287637.31 | 0.27 | 201.13 | 30-MAR-16:10 | 1.07 |
| April | 0.131458E+09 | 0.66 | 206.25 | 04-APR-16:15 | 1.06 |
| May | 0.297616E+09 | 0.98 | 272.71 | 30-MAY-18:00 | 1.05 |
| June | 0.491544E+09 | 1.06 | 348.59 | 06-JUN-17:05 | 1.03 |
| July | 0.583110E+09 | 1.06 | 368.25 | 15-JUL-17:05 | 1.03 |
| August | 0.612550E+09 | 1.06 | 370.38 | 01-AUG-17:00 | 1.03 |
| September | 0.354542E+09 | 1.01 | 308.39 | 07-SEP-16:10 | 1.04 |
| October | 0.100203E+09 | 0.46 | 243.24 | 18-OCT-16:05 | 1.05 |
| November | 23358292.38 | 0.26 | 146.16 | 05-NOV-16:05 | 1.08 |
| December | 80491088.78 | 0.67 | 126.38 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.294549E+10 | 0.74 | |||
| Minimum of Months | 23358292.38 | 0.26 | 126.38 | 0.96 | |
| Maximum of Months | 0.612550E+09 | 1.06 | 370.38 | 1.08 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.65 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.148661E+09 | 0.83 | 157.86 | 07-JAN-10:00 | 0.96 |
| February | 88671023.78 | 0.54 | 201.71 | 12-FEB-06:00 | 0.96 |
| March | 33299826.89 | 0.27 | 200.42 | 30-MAR-16:10 | 1.07 |
| April | 0.131609E+09 | 0.66 | 205.91 | 04-APR-16:15 | 1.06 |
| May | 0.297927E+09 | 0.98 | 272.59 | 30-MAY-18:00 | 1.05 |
| June | 0.491777E+09 | 1.06 | 348.01 | 06-JUN-17:05 | 1.03 |
| July | 0.583364E+09 | 1.06 | 367.37 | 15-JUL-17:08 | 1.03 |
| August | 0.612469E+09 | 1.06 | 369.88 | 01-AUG-17:00 | 1.03 |
| September | 0.354610E+09 | 1.01 | 308.13 | 07-SEP-16:10 | 1.04 |
| October | 0.100692E+09 | 0.46 | 243.29 | 18-OCT-16:05 | 1.05 |
| November | 23307456.47 | 0.26 | 145.37 | 05-NOV-16:05 | 1.08 |
| December | 80446248.76 | 0.67 | 126.33 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.294683E+10 | 0.74 | |||
| Minimum of Months | 23307456.47 | 0.26 | 126.33 | 0.96 | |
| Maximum of Months | 0.612469E+09 | 1.06 | 369.88 | 1.08 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.65 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 87663035.51 | 0.58 | 145.90 | 07-JAN-10:00 | 0.96 |
| February | 76912883.77 | 0.52 | 210.79 | 26-FEB-15:00 | 1.07 |
| March | 80406360.70 | 0.43 | 265.60 | 30-MAR-14:10 | 1.05 |
| April | 0.182910E+09 | 0.75 | 256.07 | 15-APR-16:07 | 1.06 |
| May | 0.323603E+09 | 0.99 | 285.19 | 29-MAY-16:15 | 1.05 |
| June | 0.496450E+09 | 1.06 | 362.73 | 25-JUN-16:02 | 1.03 |
| July | 0.594967E+09 | 1.06 | 387.52 | 08-JUL-16:03 | 1.03 |
| August | 0.655247E+09 | 1.05 | 394.62 | 19-AUG-16:10 | 1.02 |
| September | 0.430087E+09 | 1.02 | 366.75 | 07-SEP-16:10 | 1.03 |
| October | 0.198504E+09 | 0.66 | 355.08 | 10-OCT-14:10 | 1.03 |
| November | 60790124.21 | 0.40 | 251.28 | 05-NOV-16:10 | 1.06 |
| December | 42110859.29 | 0.42 | 172.34 | 12-DEC-14:00 | 1.07 |
| Annual Sum or Average | 0.322965E+10 | 0.75 | |||
| Minimum of Months | 42110859.29 | 0.40 | 145.90 | 0.96 | |
| Maximum of Months | 0.655247E+09 | 1.06 | 394.62 | 1.07 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.65 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 87736225.53 | 0.58 | 145.85 | 07-JAN-10:00 | 0.96 |
| February | 77203027.70 | 0.52 | 212.86 | 26-FEB-15:00 | 1.07 |
| March | 80586188.53 | 0.43 | 265.62 | 30-MAR-14:10 | 1.05 |
| April | 0.183093E+09 | 0.75 | 255.64 | 15-APR-16:07 | 1.06 |
| May | 0.323898E+09 | 0.99 | 284.77 | 29-MAY-16:15 | 1.05 |
| June | 0.496691E+09 | 1.06 | 362.23 | 25-JUN-16:02 | 1.03 |
| July | 0.595214E+09 | 1.06 | 387.26 | 08-JUL-16:03 | 1.03 |
| August | 0.655143E+09 | 1.05 | 394.32 | 19-AUG-16:10 | 1.02 |
| September | 0.430097E+09 | 1.02 | 366.65 | 06-SEP-13:00 | 1.03 |
| October | 0.198765E+09 | 0.66 | 355.39 | 10-OCT-14:10 | 1.03 |
| November | 60847241.51 | 0.40 | 250.50 | 05-NOV-16:10 | 1.06 |
| December | 42164732.38 | 0.42 | 172.39 | 12-DEC-14:00 | 1.07 |
| Annual Sum or Average | 0.323144E+10 | 0.75 | |||
| Minimum of Months | 42164732.38 | 0.40 | 145.85 | 0.96 | |
| Maximum of Months | 0.655143E+09 | 1.06 | 394.32 | 1.07 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.66 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.64 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.64 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.65 |
| December | 0.107173E+09 | 0.66 | 40.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.64 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.66 | 40.01 | 01-JAN-00:10 | 0.65 |
| February | 96801429.15 | 0.66 | 40.01 | 01-FEB-00:10 | 0.65 |
| March | 0.107173E+09 | 0.65 | 40.01 | 01-MAR-00:10 | 0.65 |
| April | 0.103716E+09 | 0.65 | 40.01 | 01-APR-00:10 | 0.65 |
| May | 0.107173E+09 | 0.65 | 40.01 | 01-MAY-00:10 | 0.65 |
| June | 0.103716E+09 | 0.65 | 40.01 | 01-JUN-00:10 | 0.65 |
| July | 0.107173E+09 | 0.65 | 40.01 | 01-JUL-00:10 | 0.65 |
| August | 0.107173E+09 | 0.65 | 40.01 | 01-AUG-00:10 | 0.65 |
| September | 0.103716E+09 | 0.65 | 40.01 | 01-SEP-00:10 | 0.65 |
| October | 0.107173E+09 | 0.65 | 40.01 | 01-OCT-00:10 | 0.65 |
| November | 0.103716E+09 | 0.65 | 40.01 | 01-NOV-00:10 | 0.66 |
| December | 0.107173E+09 | 0.65 | 40.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.126188E+10 | 0.65 | |||
| Minimum of Months | 96801429.15 | 0.65 | 40.01 | 0.65 | |
| Maximum of Months | 0.107173E+09 | 0.66 | 40.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.175072E+09 | 0.84 | 183.97 | 07-JAN-10:00 | 0.96 |
| February | 0.127522E+09 | 0.77 | 246.86 | 12-FEB-06:00 | 0.96 |
| March | 76777358.83 | 0.61 | 237.60 | 30-MAR-16:20 | 1.04 |
| April | 0.108852E+09 | 0.58 | 230.25 | 17-APR-16:10 | 1.04 |
| May | 0.189440E+09 | 0.71 | 266.62 | 19-MAY-16:10 | 1.03 |
| June | 0.327555E+09 | 0.97 | 328.58 | 25-JUN-16:02 | 1.01 |
| July | 0.394032E+09 | 1.02 | 348.44 | 08-JUL-16:01 | 1.00 |
| August | 0.434293E+09 | 1.05 | 359.86 | 01-AUG-17:00 | 1.00 |
| September | 0.238187E+09 | 0.87 | 321.19 | 07-SEP-16:10 | 1.01 |
| October | 0.107694E+09 | 0.63 | 280.11 | 10-OCT-16:02 | 1.02 |
| November | 73330721.89 | 0.58 | 179.22 | 05-NOV-16:10 | 1.05 |
| December | 0.122608E+09 | 0.76 | 163.16 | 17-DEC-04:50 | 0.95 |
| Annual Sum or Average | 0.237536E+10 | 0.78 | |||
| Minimum of Months | 73330721.89 | 0.58 | 163.16 | 0.95 | |
| Maximum of Months | 0.434293E+09 | 1.05 | 359.86 | 1.05 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.212161E+09 | 0.90 | 190.58 | 07-JAN-10:00 | 0.96 |
| February | 0.141596E+09 | 0.80 | 250.23 | 12-FEB-06:00 | 0.96 |
| March | 65323944.64 | 0.59 | 198.50 | 30-MAR-16:30 | 1.05 |
| April | 88283359.75 | 0.56 | 193.82 | 17-APR-16:50 | 1.05 |
| May | 0.175942E+09 | 0.71 | 255.23 | 19-MAY-17:30 | 1.03 |
| June | 0.324814E+09 | 0.97 | 326.90 | 06-JUN-17:00 | 1.01 |
| July | 0.388451E+09 | 1.02 | 333.03 | 15-JUL-16:40 | 1.00 |
| August | 0.411896E+09 | 1.05 | 350.36 | 01-AUG-17:00 | 1.00 |
| September | 0.198975E+09 | 0.84 | 284.71 | 07-SEP-16:13 | 1.02 |
| October | 73527088.99 | 0.61 | 201.39 | 10-OCT-16:02 | 1.05 |
| November | 75361017.82 | 0.62 | 145.89 | 22-NOV-06:00 | 0.96 |
| December | 0.151209E+09 | 0.87 | 170.31 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.230754E+10 | 0.80 | |||
| Minimum of Months | 65323944.64 | 0.56 | 145.89 | 0.96 | |
| Maximum of Months | 0.411896E+09 | 1.05 | 350.36 | 1.05 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.172915E+09 | 0.83 | 182.21 | 07-JAN-10:00 | 0.96 |
| February | 0.124833E+09 | 0.77 | 244.84 | 12-FEB-06:00 | 0.96 |
| March | 69056517.85 | 0.59 | 206.08 | 30-MAR-14:10 | 1.04 |
| April | 0.103343E+09 | 0.57 | 203.06 | 16-APR-14:00 | 1.04 |
| May | 0.187234E+09 | 0.72 | 237.40 | 30-MAY-15:10 | 1.03 |
| June | 0.324754E+09 | 0.97 | 295.78 | 06-JUN-14:10 | 1.01 |
| July | 0.390606E+09 | 1.02 | 313.65 | 08-JUL-13:00 | 1.00 |
| August | 0.425100E+09 | 1.05 | 321.73 | 19-AUG-14:00 | 1.00 |
| September | 0.234214E+09 | 0.87 | 302.83 | 06-SEP-13:00 | 1.00 |
| October | 0.102806E+09 | 0.63 | 253.56 | 10-OCT-14:00 | 1.02 |
| November | 68415428.91 | 0.57 | 147.94 | 05-NOV-15:30 | 1.06 |
| December | 0.119392E+09 | 0.76 | 161.33 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.232267E+10 | 0.78 | |||
| Minimum of Months | 68415428.91 | 0.57 | 147.94 | 0.95 | |
| Maximum of Months | 0.425100E+09 | 1.05 | 321.73 | 1.06 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.209810E+09 | 0.91 | 188.73 | 07-JAN-10:00 | 0.96 |
| February | 0.138005E+09 | 0.80 | 248.06 | 12-FEB-06:00 | 0.96 |
| March | 60151356.17 | 0.56 | 156.74 | 30-MAR-16:10 | 1.06 |
| April | 82647180.32 | 0.56 | 150.19 | 19-APR-15:10 | 1.06 |
| May | 0.174144E+09 | 0.72 | 224.94 | 30-MAY-15:10 | 1.03 |
| June | 0.322133E+09 | 0.97 | 281.64 | 06-JUN-16:40 | 1.01 |
| July | 0.385124E+09 | 1.02 | 293.80 | 07-JUL-13:00 | 1.00 |
| August | 0.403363E+09 | 1.05 | 303.41 | 01-AUG-17:00 | 1.00 |
| September | 0.195906E+09 | 0.85 | 252.47 | 06-SEP-13:00 | 1.02 |
| October | 68629436.19 | 0.60 | 162.63 | 10-OCT-16:03 | 1.05 |
| November | 72185770.81 | 0.61 | 144.18 | 22-NOV-06:00 | 0.96 |
| December | 0.148577E+09 | 0.87 | 165.84 | 17-DEC-04:00 | 0.95 |
| Annual Sum or Average | 0.226068E+10 | 0.79 | |||
| Minimum of Months | 60151356.17 | 0.56 | 144.18 | 0.95 | |
| Maximum of Months | 0.403363E+09 | 1.05 | 303.41 | 1.06 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.149274E+09 | 0.89 | 129.64 | 07-JAN-10:00 | 0.96 |
| February | 95201538.72 | 0.75 | 174.98 | 12-FEB-06:00 | 0.96 |
| March | 40900887.88 | 0.51 | 134.74 | 30-MAR-16:10 | 1.06 |
| April | 65948374.21 | 0.54 | 128.24 | 19-APR-15:10 | 1.06 |
| May | 0.146168E+09 | 0.76 | 183.71 | 30-MAY-15:10 | 1.04 |
| June | 0.271528E+09 | 0.99 | 231.63 | 06-JUN-17:00 | 1.02 |
| July | 0.326769E+09 | 1.04 | 246.72 | 08-JUL-16:03 | 1.01 |
| August | 0.344446E+09 | 1.05 | 251.11 | 01-AUG-17:00 | 1.01 |
| September | 0.171164E+09 | 0.87 | 205.26 | 07-SEP-16:10 | 1.03 |
| October | 52226392.87 | 0.53 | 142.20 | 18-OCT-16:03 | 1.05 |
| November | 47927912.86 | 0.56 | 103.36 | 22-NOV-06:00 | 0.96 |
| December | 0.101904E+09 | 0.85 | 115.59 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.181346E+10 | 0.78 | |||
| Minimum of Months | 40900887.88 | 0.51 | 103.36 | 0.96 | |
| Maximum of Months | 0.344446E+09 | 1.05 | 251.11 | 1.06 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.149242E+09 | 0.89 | 129.64 | 14-JAN-07:00 | 0.96 |
| February | 95171519.66 | 0.75 | 174.96 | 12-FEB-06:00 | 0.96 |
| March | 40952423.36 | 0.51 | 134.01 | 30-MAR-16:10 | 1.06 |
| April | 66109203.83 | 0.54 | 128.07 | 19-APR-15:10 | 1.06 |
| May | 0.146425E+09 | 0.76 | 183.75 | 30-MAY-15:10 | 1.04 |
| June | 0.271651E+09 | 0.99 | 230.77 | 06-JUN-17:00 | 1.02 |
| July | 0.326812E+09 | 1.04 | 246.13 | 08-JUL-16:03 | 1.01 |
| August | 0.344282E+09 | 1.05 | 250.22 | 01-AUG-17:00 | 1.01 |
| September | 0.171243E+09 | 0.87 | 204.68 | 07-SEP-16:10 | 1.03 |
| October | 52333351.45 | 0.53 | 142.11 | 18-OCT-16:03 | 1.05 |
| November | 47935916.79 | 0.55 | 103.31 | 22-NOV-06:00 | 0.96 |
| December | 0.101863E+09 | 0.85 | 115.51 | 02-DEC-08:00 | 0.96 |
| Annual Sum or Average | 0.181402E+10 | 0.78 | |||
| Minimum of Months | 40952423.36 | 0.51 | 103.31 | 0.96 | |
| Maximum of Months | 0.344282E+09 | 1.05 | 250.22 | 1.06 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.113665E+09 | 0.78 | 123.50 | 14-JAN-07:00 | 0.96 |
| February | 82545058.18 | 0.69 | 171.46 | 12-FEB-06:00 | 0.96 |
| March | 51503701.26 | 0.54 | 180.84 | 30-MAR-14:10 | 1.04 |
| April | 87289001.49 | 0.56 | 170.76 | 16-APR-14:00 | 1.05 |
| May | 0.159875E+09 | 0.77 | 196.37 | 30-MAY-15:10 | 1.04 |
| June | 0.274266E+09 | 0.99 | 243.38 | 25-JUN-16:02 | 1.02 |
| July | 0.332509E+09 | 1.04 | 265.60 | 08-JUL-16:03 | 1.01 |
| August | 0.367008E+09 | 1.05 | 265.05 | 19-AUG-14:00 | 1.01 |
| September | 0.211005E+09 | 0.88 | 248.33 | 06-SEP-13:30 | 1.01 |
| October | 88760615.55 | 0.59 | 227.21 | 10-OCT-14:10 | 1.02 |
| November | 48187483.15 | 0.53 | 147.58 | 05-NOV-15:30 | 1.05 |
| December | 75914882.40 | 0.69 | 105.92 | 17-DEC-05:00 | 0.95 |
| Annual Sum or Average | 0.189253E+10 | 0.76 | |||
| Minimum of Months | 48187483.15 | 0.53 | 105.92 | 0.95 | |
| Maximum of Months | 0.367008E+09 | 1.05 | 265.60 | 1.05 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.113714E+09 | 0.78 | 123.54 | 14-JAN-07:00 | 0.96 |
| February | 82647070.07 | 0.69 | 171.45 | 12-FEB-06:00 | 0.96 |
| March | 51625868.74 | 0.54 | 180.98 | 30-MAR-14:10 | 1.04 |
| April | 87473091.65 | 0.56 | 171.55 | 16-APR-14:00 | 1.05 |
| May | 0.160123E+09 | 0.77 | 196.41 | 30-MAY-15:10 | 1.04 |
| June | 0.274398E+09 | 0.99 | 242.69 | 25-JUN-16:02 | 1.02 |
| July | 0.332552E+09 | 1.04 | 264.99 | 08-JUL-16:03 | 1.01 |
| August | 0.366821E+09 | 1.05 | 265.28 | 19-AUG-14:00 | 1.01 |
| September | 0.211024E+09 | 0.88 | 248.92 | 06-SEP-13:30 | 1.01 |
| October | 89010176.39 | 0.59 | 227.50 | 10-OCT-14:10 | 1.02 |
| November | 48281652.24 | 0.53 | 146.94 | 05-NOV-15:30 | 1.05 |
| December | 75943165.12 | 0.69 | 105.87 | 17-DEC-05:00 | 0.95 |
| Annual Sum or Average | 0.189361E+10 | 0.76 | |||
| Minimum of Months | 48281652.24 | 0.53 | 105.87 | 0.95 | |
| Maximum of Months | 0.366821E+09 | 1.05 | 265.28 | 1.05 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.66 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.64 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.64 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.65 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.66 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.64 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.66 | 20.01 | 01-JAN-00:10 | 0.65 |
| February | 48400714.57 | 0.66 | 20.01 | 01-FEB-00:10 | 0.65 |
| March | 53586505.42 | 0.65 | 20.01 | 01-MAR-00:10 | 0.65 |
| April | 51857908.47 | 0.65 | 20.01 | 01-APR-00:10 | 0.65 |
| May | 53586505.42 | 0.65 | 20.01 | 01-MAY-00:10 | 0.65 |
| June | 51857908.47 | 0.65 | 20.01 | 01-JUN-00:10 | 0.65 |
| July | 53586505.42 | 0.65 | 20.01 | 01-JUL-00:10 | 0.65 |
| August | 53586505.42 | 0.65 | 20.01 | 01-AUG-00:10 | 0.65 |
| September | 51857908.47 | 0.65 | 20.01 | 01-SEP-00:10 | 0.65 |
| October | 53586505.42 | 0.65 | 20.01 | 01-OCT-00:10 | 0.65 |
| November | 51857908.47 | 0.65 | 20.01 | 01-NOV-00:10 | 0.66 |
| December | 53586505.42 | 0.66 | 20.01 | 01-DEC-00:10 | 0.65 |
| Annual Sum or Average | 0.630938E+09 | 0.65 | |||
| Minimum of Months | 48400714.57 | 0.65 | 20.01 | 0.65 | |
| Maximum of Months | 53586505.42 | 0.66 | 20.01 | 0.66 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.101916E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 77533146.91 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 43524479.85 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.129220E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.417607E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.106698E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.141378E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.164713E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.104323E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.420915E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 81716466.20 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 46782870.43 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.649034E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 43524479.85 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.164713E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.134575E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 90493087.48 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 36143098.76 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 73155840.12 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.369155E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.105953E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.139269E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.155832E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.886328E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.233220E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 23427183.74 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 71130884.35 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.592816E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 23427183.74 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.155832E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.110846E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.101912E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.117463E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.121636E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.143093E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.170377E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.182692E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.198736E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.162632E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.139569E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.117499E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.112745E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.167920E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.101912E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.198736E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.133423E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 88765407.73 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 32261382.20 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 71258174.84 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.376366E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.106968E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.140416E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.154985E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.886061E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.230866E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 20994671.03 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 69762557.84 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.593344E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 20994671.03 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.154985E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 89797534.94 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 57447998.55 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 18524260.48 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 72622060.52 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.362505E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.942985E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.122073E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.133812E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.790048E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.217359E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 14673689.95 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 42234929.99 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.516706E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 14673689.95 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.133812E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 89792493.54 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 57409989.52 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 18496998.97 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 72856631.16 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.363442E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.943890E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.122173E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.133822E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.790325E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.218169E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 14564725.08 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 42206457.04 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.517110E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 14564725.08 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.133822E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 59680953.82 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 49378089.51 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 36552077.80 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.138161E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.419083E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.954518E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.124773E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.143421E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.955445E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.429804E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.108679E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 22778901.14 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.585601E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 22778901.14 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.143421E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 66486125.08 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 53738400.98 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 40593608.07 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.153213E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.461638E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.103315E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.135202E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.154104E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.103847E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.467568E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.119292E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 24662930.37 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.635188E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 24662930.37 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.154104E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.178883E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.192418E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.344936E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.877817E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.167491E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.277501E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.334183E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.366463E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.219211E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.879800E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.183721E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.115676E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.164217E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.115676E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.366463E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.246155E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.159087E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.165178E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.661765E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.155871E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.275200E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.328691E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.346698E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.185112E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.483165E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 66539275.74 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.154226E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.148518E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 66539275.74 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.346698E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.177233E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.194758E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.314173E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.864036E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.169097E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.279432E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.336225E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.364277E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.218926E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.880879E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.168421E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.111246E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.163903E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.111246E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.364277E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.243921E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.154602E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.143169E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.646286E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.157519E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.277078E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.330667E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.344650E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.185151E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.472535E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 60869932.57 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.151191E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.148232E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 60869932.57 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.344650E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.148658E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 94381360.12 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.131906E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.595365E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.136215E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.229873E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.275151E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.288385E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.163383E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.454526E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 44392364.93 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 80491088.78 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.124798E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 44392364.93 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.288385E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.148661E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 94562918.09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.131773E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.596159E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.136382E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.230025E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.275321E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.288404E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.163446E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.456737E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 44156111.58 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 80446248.76 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.124883E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 44156111.58 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.288404E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 87663035.51 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.160115E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.357371E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.826029E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.147913E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.231998E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.280530E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.308165E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.197807E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.897777E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.256122E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 71249083.36 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.143205E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 71249083.36 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.308165E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 87736225.53 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.161552E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.358222E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.827003E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.148075E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.232154E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.280700E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.308178E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.197850E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.899116E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.256463E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 71427666.30 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.143311E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 71427666.30 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.308178E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.175970E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.169890E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.215607E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.446302E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.854814E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.152085E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.184542E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.202637E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.108705E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.416896E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.140614E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.133318E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.903310E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133318E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.202637E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.212161E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.151126E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.132089E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.345582E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.793815E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.150760E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.181866E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.192188E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.909169E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.242265E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 84582338.17 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.151358E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.827028E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 84582338.17 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.192188E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.173634E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.165560E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.188626E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.430136E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.856086E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.152665E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.185186E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.200881E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.108266E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.402521E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.125974E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.127730E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.894025E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.125974E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.200881E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.209810E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.145153E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.116203E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.328262E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.796096E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.151383E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.182530E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.190615E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.906731E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.227088E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 78638575.37 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.148618E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.820188E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 78638575.37 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.190615E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.149274E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 99696462.90 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 89003124.06 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.268934E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.663969E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.126311E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.153303E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.161102E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.784498E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.190220E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 54981996.48 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.101946E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.680968E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 54981996.48 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.161102E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.149242E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 99732017.11 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 89010927.89 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.269759E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.665397E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.126420E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.153387E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.161096E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.785200E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.190761E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 54933392.06 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.101902E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.681497E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 54933392.06 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.161096E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.114956E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.119571E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.164738E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.371205E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.726147E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.127640E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.156064E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.171671E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.965881E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.369561E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.112043E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 87407412.49 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.758526E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 87407412.49 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.171671E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.115091E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.120099E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.165184E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.372152E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.727561E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.127754E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.156149E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.171658E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.966377E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.370762E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.112450E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 87539028.17 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.759282E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 87539028.17 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.171658E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.101916E+09 | 0.00 | 0.222349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 70059544.45 | 28303120.79 | 0.148099E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 20783014.26 | 87144184.38 | 0.313796E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 31151655.60 | 0.374551E+09 | 77562684.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 90475110.14 | 0.127130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.226865E+09 | 0.325080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.298395E+09 | 0.433680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349143E+09 | 0.512279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.226164E+09 | 0.326725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 92779241.79 | 0.131415E+10 | 939594.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 22765004.68 | 0.230512E+09 | 0.126133E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 44752465.04 | 7972858.41 | 0.963762E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.157525E+10 | 0.192916E+11 | 0.518667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20783014.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.349143E+09 | 0.512279E+10 | 0.222349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.134575E+09 | 0.00 | 0.294319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 90493087.48 | 0.00 | 0.197910E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 29324211.43 | 25938131.32 | 0.600110E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 20755165.40 | 0.199688E+09 | 0.132560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 79829204.13 | 0.112360E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.225140E+09 | 0.323346E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.293745E+09 | 0.427762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.329969E+09 | 0.484888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.191772E+09 | 0.277248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 51602393.60 | 0.728624E+09 | 14428729.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 17381683.18 | 24206913.21 | 0.342715E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 71130884.35 | 0.00 | 0.155565E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.153572E+10 | 0.172345E+11 | 0.756775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17381683.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.329969E+09 | 0.484888E+10 | 0.294319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.110846E+10 | 0.00 | 0.717283E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100119E+10 | 68693347.90 | 0.469902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.110846E+10 | 0.259575E+09 | 19571737.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107270E+10 | 0.562982E+09 | 226173.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.110846E+10 | 0.129125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.107270E+10 | 0.253013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.110846E+10 | 0.290235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.110846E+10 | 0.359770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.107270E+10 | 0.229315E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.110846E+10 | 0.117779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107270E+10 | 0.401348E+09 | 1534447.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.110846E+10 | 75661329.10 | 82933931.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.130512E+11 | 0.151606E+11 | 0.129145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.100119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.110846E+10 | 0.359770E+10 | 0.717283E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.133423E+09 | 0.00 | 0.294161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88765407.73 | 0.00 | 0.195704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 28039554.18 | 15962582.59 | 0.592902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 19990156.71 | 0.195232E+09 | 0.128395E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 80527950.27 | 0.115196E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.224895E+09 | 0.328537E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.293041E+09 | 0.434475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.324569E+09 | 0.485364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.189613E+09 | 0.278704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50568229.17 | 0.724905E+09 | 15854978.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 16388408.37 | 18520826.57 | 0.333058E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 69762557.84 | 0.00 | 0.153808E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.151958E+10 | 0.173774E+11 | 0.750694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 16388408.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.324569E+09 | 0.485364E+10 | 0.294161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 89797534.94 | 0.00 | 0.200193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 57447998.55 | 0.00 | 0.128073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 13934498.56 | 17444967.27 | 0.282792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 17013109.54 | 0.214139E+09 | 36401133.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 77669493.28 | 0.111288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.198483E+09 | 0.289717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.254942E+09 | 0.377706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.280351E+09 | 0.418952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.169149E+09 | 0.248599E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 47097086.10 | 0.684745E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 8453106.35 | 24985685.75 | 0.149842E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42234929.99 | 0.00 | 0.941576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125657E+10 | 0.154039E+11 | 0.469327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 8453106.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.280351E+09 | 0.418952E+10 | 0.200193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 89792493.54 | 0.00 | 0.200217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 57409989.52 | 0.00 | 0.128011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 13960523.88 | 17238868.80 | 0.283756E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 17072657.63 | 0.214787E+09 | 36745598.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 77856283.12 | 0.111584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.198636E+09 | 0.290027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.255103E+09 | 0.378068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.280312E+09 | 0.419023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.169173E+09 | 0.248709E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 47264866.99 | 0.687304E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 8425151.22 | 24661950.69 | 0.149759E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42206457.04 | 0.00 | 0.941108E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125721E+10 | 0.154181E+11 | 0.469365E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 8425151.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.280312E+09 | 0.419023E+10 | 0.200217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 59680953.82 | 0.00 | 0.132444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 40027241.44 | 35468038.47 | 0.828726E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 11263249.82 | 97120305.04 | 93498968.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 30443860.91 | 0.414707E+09 | 12119150.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 89970394.67 | 0.128626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.201060E+09 | 0.292593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.260788E+09 | 0.385300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.300835E+09 | 0.448502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.204989E+09 | 0.300877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 93749616.32 | 0.134580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 24758767.53 | 0.328176E+09 | 20624381.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 19030083.57 | 14755244.41 | 0.399005E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.133660E+10 | 0.177950E+11 | 0.267842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11263249.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.300835E+09 | 0.448502E+10 | 0.132444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 66486125.08 | 0.00 | 0.147409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 43760632.05 | 37867076.46 | 0.906651E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 12135128.27 | 0.109417E+09 | 92724923.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 33686744.52 | 0.461035E+09 | 9906828.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 99305891.16 | 0.141886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.218150E+09 | 0.317296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283303E+09 | 0.418443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.323965E+09 | 0.482851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.223225E+09 | 0.327506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.102142E+09 | 0.146422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 27094440.49 | 0.360722E+09 | 19538398.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 20772919.12 | 15321975.63 | 0.436372E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145403E+10 | 0.193284E+11 | 0.293928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 12135128.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.323965E+09 | 0.482851E+10 | 0.147409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.178883E+09 | 0.00 | 0.383575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.127587E+09 | 0.248217E+09 | 0.232373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 84398362.45 | 0.101478E+10 | 0.189676E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.196664E+09 | 0.266013E+10 | 13619831.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.369614E+09 | 0.513146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.598714E+09 | 0.843560E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.714623E+09 | 0.101979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.785936E+09 | 0.113107E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.480622E+09 | 0.681062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.197958E+09 | 0.272570E+10 | 50878597.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 57191389.95 | 0.495426E+09 | 0.432880E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101697E+09 | 54828994.73 | 0.209384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.389389E+10 | 0.490853E+11 | 0.894037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 57191389.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.785936E+09 | 0.113107E+11 | 0.383575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.246155E+09 | 0.00 | 0.528630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.151336E+09 | 29296878.85 | 0.320087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 52062727.88 | 0.440248E+09 | 0.422311E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.149215E+09 | 0.199849E+10 | 46374739.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.343596E+09 | 0.477525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.593417E+09 | 0.837661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.702456E+09 | 0.100402E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.742892E+09 | 0.107052E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.405122E+09 | 0.574552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.111464E+09 | 0.149020E+10 | 0.122683E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50920047.11 | 62734077.27 | 0.997213E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.154226E+09 | 0.00 | 0.331209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.370286E+10 | 0.436638E+11 | 0.133878E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50920047.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.742892E+09 | 0.107052E+11 | 0.528630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.177233E+09 | 0.00 | 0.382838E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.126676E+09 | 0.260713E+09 | 0.230627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 76660709.86 | 0.925755E+09 | 0.189503E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.191454E+09 | 0.262961E+10 | 12257622.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.369254E+09 | 0.521151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.596690E+09 | 0.855267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.711658E+09 | 0.103399E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.772973E+09 | 0.113203E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.474915E+09 | 0.684355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.196210E+09 | 0.274128E+10 | 53254001.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52640414.87 | 0.453027E+09 | 0.416050E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 98682319.39 | 49444543.06 | 0.205423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.384505E+10 | 0.493278E+11 | 0.885995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52640414.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.772973E+09 | 0.113203E+11 | 0.382838E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.243921E+09 | 0.00 | 0.527826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.148084E+09 | 24628179.78 | 0.316342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 46123749.60 | 0.377963E+09 | 0.405716E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.144051E+09 | 0.195983E+10 | 43343732.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.343546E+09 | 0.485423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.591243E+09 | 0.849286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.699360E+09 | 0.101803E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.730569E+09 | 0.107143E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.400858E+09 | 0.577933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.107861E+09 | 0.146635E+10 | 0.121283E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 48366579.65 | 50261220.95 | 0.970105E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.151191E+09 | 0.00 | 0.327167E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.365518E+10 | 0.439001E+11 | 0.132538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46123749.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.730569E+09 | 0.107143E+11 | 0.527826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.148658E+09 | 0.00 | 0.325070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88670857.38 | 21584715.71 | 0.190262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 33287637.31 | 0.384179E+09 | 0.117446E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.131458E+09 | 0.181443E+10 | 381180.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.297616E+09 | 0.419383E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491544E+09 | 0.703058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.583110E+09 | 0.845669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.612550E+09 | 0.895415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.354542E+09 | 0.510051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.100203E+09 | 0.142469E+10 | 11781273.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 23358292.38 | 84550667.11 | 0.380478E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 80491088.78 | 0.00 | 0.176010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.294549E+10 | 0.374652E+11 | 0.742351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23358292.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.612550E+09 | 0.895415E+10 | 0.325070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.148661E+09 | 0.00 | 0.325123E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88671023.78 | 22272302.98 | 0.190175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 33299826.89 | 0.383631E+09 | 0.118787E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.131609E+09 | 0.181688E+10 | 387867.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.297927E+09 | 0.419932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491777E+09 | 0.703591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.583364E+09 | 0.846292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.612469E+09 | 0.895547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.354610E+09 | 0.510286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.100692E+09 | 0.143149E+10 | 12236092.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 23307456.47 | 83806252.72 | 0.380602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 80446248.76 | 0.00 | 0.175937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.294683E+10 | 0.374946E+11 | 0.742437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23307456.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.612469E+09 | 0.895547E+10 | 0.325123E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 87663035.51 | 0.00 | 0.191201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 76912883.77 | 0.318943E+09 | 0.114604E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 80406360.70 | 0.107894E+10 | 19693831.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.182910E+09 | 0.251621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.323603E+09 | 0.455271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.496450E+09 | 0.708338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.594967E+09 | 0.860999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.655247E+09 | 0.955954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.430087E+09 | 0.617924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198504E+09 | 0.279731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 60790124.21 | 0.764581E+09 | 94736842.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42110859.29 | 0.114502E+09 | 0.736344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.322965E+10 | 0.435754E+11 | 0.390882E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42110859.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.655247E+09 | 0.955954E+10 | 0.191201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 87736225.53 | 0.00 | 0.191388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77203027.70 | 0.323381E+09 | 0.114532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 80586188.53 | 0.108157E+10 | 19779823.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.183093E+09 | 0.251936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.323898E+09 | 0.455815E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.496691E+09 | 0.708889E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.595214E+09 | 0.861625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.655143E+09 | 0.956084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.430097E+09 | 0.618122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198765E+09 | 0.280171E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 60847241.51 | 0.765652E+09 | 94430216.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42164732.38 | 0.114982E+09 | 0.736878E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.323144E+10 | 0.436120E+11 | 0.391028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42164732.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.655143E+09 | 0.956084E+10 | 0.191388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.175072E+09 | 3356976.86 | 0.371221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.127522E+09 | 0.162884E+09 | 0.244017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 76777358.83 | 0.540802E+09 | 0.771776E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.108852E+09 | 0.131696E+10 | 0.243801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.189440E+09 | 0.261110E+10 | 22375231.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.327555E+09 | 0.460865E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.394032E+09 | 0.560591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.434293E+09 | 0.623116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.238187E+09 | 0.336801E+10 | 1932023.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.107694E+09 | 0.123635E+10 | 0.401308E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73330721.89 | 0.262808E+09 | 0.113645E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122608E+09 | 41496254.77 | 0.253691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.237536E+10 | 0.259895E+11 | 0.112669E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 73330721.89 | 3356976.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.434293E+09 | 0.623116E+10 | 0.371221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.212161E+09 | 0.00 | 0.450863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.141596E+09 | 36112122.71 | 0.294887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 65323944.64 | 0.260289E+09 | 0.980130E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 88283359.75 | 0.100027E+10 | 0.300814E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.175942E+09 | 0.242172E+10 | 22772754.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.324814E+09 | 0.457093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.388451E+09 | 0.552535E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.411896E+09 | 0.590526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.198975E+09 | 0.280897E+10 | 2088033.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 73527088.99 | 0.675769E+09 | 0.541005E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 75361017.82 | 36800405.34 | 0.154488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.151209E+09 | 583066.32 | 0.321241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230754E+10 | 0.232421E+11 | 0.140616E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 65323944.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.411896E+09 | 0.590526E+10 | 0.450863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.172915E+09 | 2697997.17 | 0.370045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.124833E+09 | 0.156615E+09 | 0.241917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69056517.85 | 0.466344E+09 | 0.746987E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.103343E+09 | 0.127696E+10 | 0.228230E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.187234E+09 | 0.263575E+10 | 19792093.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.324754E+09 | 0.466981E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.390606E+09 | 0.568458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.425100E+09 | 0.623513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.234214E+09 | 0.338209E+10 | 1930826.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.102806E+09 | 0.120232E+10 | 0.389967E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 68415428.91 | 0.224805E+09 | 0.110899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.119392E+09 | 32448358.60 | 0.250671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.232267E+10 | 0.259695E+11 | 0.111222E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 68415428.91 | 2697997.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.425100E+09 | 0.623513E+10 | 0.370045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.209810E+09 | 0.00 | 0.449939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.138005E+09 | 26997427.15 | 0.291479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 60151356.17 | 0.218629E+09 | 0.950543E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 82647180.32 | 0.954998E+09 | 0.281461E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.174144E+09 | 0.244720E+10 | 20807832.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.322133E+09 | 0.463316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.385124E+09 | 0.560395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.403363E+09 | 0.591023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.195906E+09 | 0.282185E+10 | 2063286.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 68629436.19 | 0.637505E+09 | 0.521252E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 72185770.81 | 25775506.06 | 0.150877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.148577E+09 | 156662.71 | 0.318601E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.226068E+10 | 0.232804E+11 | 0.138851E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 60151356.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.403363E+09 | 0.591023E+10 | 0.449939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.149274E+09 | 0.00 | 0.322338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95201538.72 | 16954918.06 | 0.202711E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 40900887.88 | 0.187606E+09 | 0.586563E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65948374.21 | 0.789579E+09 | 0.169241E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.146168E+09 | 0.203211E+10 | 5959541.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271528E+09 | 0.383947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.326769E+09 | 0.467510E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.344446E+09 | 0.496511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.171164E+09 | 0.243282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 52226392.87 | 0.555830E+09 | 0.284044E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 47927912.86 | 28217470.71 | 0.991227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101904E+09 | 165035.50 | 0.220022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.181346E+10 | 0.195230E+11 | 0.948775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40900887.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.344446E+09 | 0.496511E+10 | 0.322338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.149242E+09 | 0.00 | 0.322378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95171519.66 | 17201438.87 | 0.202674E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 40952423.36 | 0.187436E+09 | 0.588299E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 66109203.83 | 0.792139E+09 | 0.169370E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.146425E+09 | 0.203694E+10 | 6051015.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271651E+09 | 0.384384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.326812E+09 | 0.467911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.344282E+09 | 0.496617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.171243E+09 | 0.243548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 52333351.45 | 0.557587E+09 | 0.284258E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 47935916.79 | 27990790.36 | 0.992109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101863E+09 | 152907.72 | 0.220010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.181402E+10 | 0.195440E+11 | 0.949070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40952423.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.344282E+09 | 0.496617E+10 | 0.322378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.113665E+09 | 4843597.05 | 0.244330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82545058.18 | 0.142216E+09 | 0.154377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51503701.26 | 0.441139E+09 | 0.403811E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87289001.49 | 0.110825E+10 | 0.125972E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.159875E+09 | 0.222498E+10 | 5629547.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.274266E+09 | 0.387676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.332509E+09 | 0.475761E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.367008E+09 | 0.529384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.211005E+09 | 0.300339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88760615.55 | 0.112522E+10 | 0.183469E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 48187483.15 | 0.249883E+09 | 0.636374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 75914882.40 | 44577933.87 | 0.156490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.189253E+10 | 0.222727E+11 | 0.690722E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48187483.15 | 4843597.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.367008E+09 | 0.529384E+10 | 0.244330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.113714E+09 | 5165465.78 | 0.244461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82647070.07 | 0.143877E+09 | 0.154387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51625868.74 | 0.442405E+09 | 0.404862E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87473091.65 | 0.111133E+10 | 0.126194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.160123E+09 | 0.222990E+10 | 5679946.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.274398E+09 | 0.388129E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.332552E+09 | 0.476167E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366821E+09 | 0.529488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.211024E+09 | 0.300573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 89010176.39 | 0.112914E+10 | 0.183880E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 48281652.24 | 0.251093E+09 | 0.636823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 75943165.12 | 44976144.99 | 0.156540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.189361E+10 | 0.223015E+11 | 0.691132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48281652.24 | 5165465.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.366821E+09 | 0.529488E+10 | 0.244461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.101916E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 70059544.45 | 0.00 | 0.00 | 0.00 | 7473602.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 20783014.26 | 0.00 | 0.00 | 0.00 | 22741465.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 31151655.60 | 0.00 | 0.00 | 0.00 | 98068671.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 90475110.14 | 0.00 | 0.00 | 0.00 | 0.327132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.226865E+09 | 0.00 | 0.00 | 0.00 | 0.840117E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.298395E+09 | 0.00 | 0.00 | 0.00 | 0.111539E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349143E+09 | 0.00 | 0.00 | 0.00 | 0.129799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.226164E+09 | 0.00 | 0.00 | 0.00 | 0.817062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 92779241.79 | 0.00 | 0.00 | 0.00 | 0.328135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 22765004.68 | 0.00 | 0.00 | 0.00 | 58951461.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 44752465.04 | 0.00 | 0.00 | 0.00 | 2030405.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.157525E+10 | 0.00 | 0.00 | 0.00 | 0.491509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20783014.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.349143E+09 | 0.00 | 0.00 | 0.00 | 0.129799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.134575E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 90493087.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 29324211.43 | 0.00 | 0.00 | 0.00 | 6818887.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 20755165.40 | 0.00 | 0.00 | 0.00 | 52400674.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 79829204.13 | 0.00 | 0.00 | 0.00 | 0.289325E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.225140E+09 | 0.00 | 0.00 | 0.00 | 0.834386E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.293745E+09 | 0.00 | 0.00 | 0.00 | 0.109894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.329969E+09 | 0.00 | 0.00 | 0.00 | 0.122835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.191772E+09 | 0.00 | 0.00 | 0.00 | 0.694556E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 51602393.60 | 0.00 | 0.00 | 0.00 | 0.181617E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 17381683.18 | 0.00 | 0.00 | 0.00 | 6045500.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 71130884.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.153572E+10 | 0.00 | 0.00 | 0.00 | 0.439244E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17381683.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.329969E+09 | 0.00 | 0.00 | 0.00 | 0.122835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100119E+10 | 0.00 | 0.00 | 0.00 | 17934352.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 66167339.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107270E+10 | 0.00 | 0.00 | 0.00 | 0.143655E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 0.322470E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.107270E+10 | 0.00 | 0.00 | 0.00 | 0.631070E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 0.718460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 0.878902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.107270E+10 | 0.00 | 0.00 | 0.00 | 0.553619E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 0.287226E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107270E+10 | 0.00 | 0.00 | 0.00 | 0.102287E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 18992022.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.130512E+11 | 0.00 | 0.00 | 0.00 | 0.374078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.100119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.110846E+10 | 0.00 | 0.00 | 0.00 | 0.878902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.133423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88765407.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 28039554.18 | 0.00 | 0.00 | 0.00 | 4221828.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 19990156.71 | 0.00 | 0.00 | 0.00 | 51268018.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 80527950.27 | 0.00 | 0.00 | 0.00 | 0.295838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.224895E+09 | 0.00 | 0.00 | 0.00 | 0.844789E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.293041E+09 | 0.00 | 0.00 | 0.00 | 0.111111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.324569E+09 | 0.00 | 0.00 | 0.00 | 0.122528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.189613E+09 | 0.00 | 0.00 | 0.00 | 0.696448E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 50568229.17 | 0.00 | 0.00 | 0.00 | 0.180298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 16388408.37 | 0.00 | 0.00 | 0.00 | 4606262.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 69762557.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.151958E+10 | 0.00 | 0.00 | 0.00 | 0.441386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 16388408.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.324569E+09 | 0.00 | 0.00 | 0.00 | 0.122528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 89797534.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 57447998.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 13934498.56 | 0.00 | 0.00 | 0.00 | 4589761.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 17013109.54 | 0.00 | 0.00 | 0.00 | 55608950.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 77669493.28 | 0.00 | 0.00 | 0.00 | 0.284835E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.198483E+09 | 0.00 | 0.00 | 0.00 | 0.744502E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.254942E+09 | 0.00 | 0.00 | 0.00 | 0.965792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.280351E+09 | 0.00 | 0.00 | 0.00 | 0.105777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.169149E+09 | 0.00 | 0.00 | 0.00 | 0.620900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 47097086.10 | 0.00 | 0.00 | 0.00 | 0.170262E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 8453106.35 | 0.00 | 0.00 | 0.00 | 6220583.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42234929.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125657E+10 | 0.00 | 0.00 | 0.00 | 0.391048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 8453106.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.280351E+09 | 0.00 | 0.00 | 0.00 | 0.105777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 89792493.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 57409989.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 13960523.88 | 0.00 | 0.00 | 0.00 | 4536475.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 17072657.63 | 0.00 | 0.00 | 0.00 | 55783973.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 77856283.12 | 0.00 | 0.00 | 0.00 | 0.285585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.198636E+09 | 0.00 | 0.00 | 0.00 | 0.745254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.255103E+09 | 0.00 | 0.00 | 0.00 | 0.966632E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.280312E+09 | 0.00 | 0.00 | 0.00 | 0.105790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.169173E+09 | 0.00 | 0.00 | 0.00 | 0.621151E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 47264866.99 | 0.00 | 0.00 | 0.00 | 0.170904E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 8425151.22 | 0.00 | 0.00 | 0.00 | 6139573.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42206457.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125721E+10 | 0.00 | 0.00 | 0.00 | 0.391389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 8425151.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.280312E+09 | 0.00 | 0.00 | 0.00 | 0.105790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 59680953.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 40027241.44 | 0.00 | 0.00 | 0.00 | 9350848.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 11263249.82 | 0.00 | 0.00 | 0.00 | 25288827.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 30443860.91 | 0.00 | 0.00 | 0.00 | 0.107717E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 89970394.67 | 0.00 | 0.00 | 0.00 | 0.329113E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.201060E+09 | 0.00 | 0.00 | 0.00 | 0.753458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.260788E+09 | 0.00 | 0.00 | 0.00 | 0.986938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.300835E+09 | 0.00 | 0.00 | 0.00 | 0.113337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.204989E+09 | 0.00 | 0.00 | 0.00 | 0.750456E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 93749616.32 | 0.00 | 0.00 | 0.00 | 0.336054E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 24758767.53 | 0.00 | 0.00 | 0.00 | 83920426.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 19030083.57 | 0.00 | 0.00 | 0.00 | 3748817.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.133660E+10 | 0.00 | 0.00 | 0.00 | 0.451942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11263249.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.300835E+09 | 0.00 | 0.00 | 0.00 | 0.113337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 66486125.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 43760632.05 | 0.00 | 0.00 | 0.00 | 9977768.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 12135128.27 | 0.00 | 0.00 | 0.00 | 28458479.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 33686744.52 | 0.00 | 0.00 | 0.00 | 0.119526E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 99305891.16 | 0.00 | 0.00 | 0.00 | 0.362332E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.218150E+09 | 0.00 | 0.00 | 0.00 | 0.815004E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283303E+09 | 0.00 | 0.00 | 0.00 | 0.106872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.323965E+09 | 0.00 | 0.00 | 0.00 | 0.121708E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.223225E+09 | 0.00 | 0.00 | 0.00 | 0.815243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.102142E+09 | 0.00 | 0.00 | 0.00 | 0.365426E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 27094440.49 | 0.00 | 0.00 | 0.00 | 92197996.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 20772919.12 | 0.00 | 0.00 | 0.00 | 3890011.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.145403E+10 | 0.00 | 0.00 | 0.00 | 0.489785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 12135128.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.323965E+09 | 0.00 | 0.00 | 0.00 | 0.121708E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.178883E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.127587E+09 | 0.00 | 0.00 | 0.00 | 64831072.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 84398362.45 | 0.00 | 0.00 | 0.00 | 0.260537E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.196664E+09 | 0.00 | 0.00 | 0.00 | 0.681153E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.369614E+09 | 0.00 | 0.00 | 0.00 | 0.130529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.598714E+09 | 0.00 | 0.00 | 0.00 | 0.217630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.714623E+09 | 0.00 | 0.00 | 0.00 | 0.262721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.785936E+09 | 0.00 | 0.00 | 0.00 | 0.287869E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.480622E+09 | 0.00 | 0.00 | 0.00 | 0.171149E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.197958E+09 | 0.00 | 0.00 | 0.00 | 0.681842E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 57191389.95 | 0.00 | 0.00 | 0.00 | 0.126529E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101697E+09 | 0.00 | 0.00 | 0.00 | 13978792.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.389389E+10 | 0.00 | 0.00 | 0.00 | 0.125279E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 57191389.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.785936E+09 | 0.00 | 0.00 | 0.00 | 0.287869E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.246155E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.151336E+09 | 0.00 | 0.00 | 0.00 | 7751188.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 52062727.88 | 0.00 | 0.00 | 0.00 | 0.113115E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.149215E+09 | 0.00 | 0.00 | 0.00 | 0.512549E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.343596E+09 | 0.00 | 0.00 | 0.00 | 0.121511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.593417E+09 | 0.00 | 0.00 | 0.00 | 0.215858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.702456E+09 | 0.00 | 0.00 | 0.00 | 0.258445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.742892E+09 | 0.00 | 0.00 | 0.00 | 0.272409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.405122E+09 | 0.00 | 0.00 | 0.00 | 0.144600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.111464E+09 | 0.00 | 0.00 | 0.00 | 0.371701E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50920047.11 | 0.00 | 0.00 | 0.00 | 15619228.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.154226E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.370286E+10 | 0.00 | 0.00 | 0.00 | 0.111490E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50920047.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.742892E+09 | 0.00 | 0.00 | 0.00 | 0.272409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.177233E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.126676E+09 | 0.00 | 0.00 | 0.00 | 68082170.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 76660709.86 | 0.00 | 0.00 | 0.00 | 0.237513E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.191454E+09 | 0.00 | 0.00 | 0.00 | 0.672582E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.369254E+09 | 0.00 | 0.00 | 0.00 | 0.132172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.596690E+09 | 0.00 | 0.00 | 0.00 | 0.219763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.711658E+09 | 0.00 | 0.00 | 0.00 | 0.265060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.772973E+09 | 0.00 | 0.00 | 0.00 | 0.286980E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.474915E+09 | 0.00 | 0.00 | 0.00 | 0.171435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.196210E+09 | 0.00 | 0.00 | 0.00 | 0.684669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52640414.87 | 0.00 | 0.00 | 0.00 | 0.115781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 98682319.39 | 0.00 | 0.00 | 0.00 | 12563300.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.384505E+10 | 0.00 | 0.00 | 0.00 | 0.125453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52640414.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.772973E+09 | 0.00 | 0.00 | 0.00 | 0.286980E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.243921E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.148084E+09 | 0.00 | 0.00 | 0.00 | 6518368.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 46123749.60 | 0.00 | 0.00 | 0.00 | 97044797.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.144051E+09 | 0.00 | 0.00 | 0.00 | 0.502235E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.343546E+09 | 0.00 | 0.00 | 0.00 | 0.123165E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.591243E+09 | 0.00 | 0.00 | 0.00 | 0.217954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.699360E+09 | 0.00 | 0.00 | 0.00 | 0.260731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.730569E+09 | 0.00 | 0.00 | 0.00 | 0.271593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.400858E+09 | 0.00 | 0.00 | 0.00 | 0.145065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.107861E+09 | 0.00 | 0.00 | 0.00 | 0.364674E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 48366579.65 | 0.00 | 0.00 | 0.00 | 12503352.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.151191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.365518E+10 | 0.00 | 0.00 | 0.00 | 0.111680E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46123749.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.730569E+09 | 0.00 | 0.00 | 0.00 | 0.271593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.148658E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88670857.38 | 0.00 | 0.00 | 0.00 | 5710502.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 33287637.31 | 0.00 | 0.00 | 0.00 | 98618151.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.131458E+09 | 0.00 | 0.00 | 0.00 | 0.463907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.297616E+09 | 0.00 | 0.00 | 0.00 | 0.106453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491544E+09 | 0.00 | 0.00 | 0.00 | 0.180719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.583110E+09 | 0.00 | 0.00 | 0.00 | 0.216840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.612550E+09 | 0.00 | 0.00 | 0.00 | 0.227130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.354542E+09 | 0.00 | 0.00 | 0.00 | 0.127929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.100203E+09 | 0.00 | 0.00 | 0.00 | 0.354323E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 23358292.38 | 0.00 | 0.00 | 0.00 | 21034072.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 80491088.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.294549E+10 | 0.00 | 0.00 | 0.00 | 0.953430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23358292.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.612550E+09 | 0.00 | 0.00 | 0.00 | 0.227130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.148661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88671023.78 | 0.00 | 0.00 | 0.00 | 5891894.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 33299826.89 | 0.00 | 0.00 | 0.00 | 98473480.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.131609E+09 | 0.00 | 0.00 | 0.00 | 0.464549E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.297927E+09 | 0.00 | 0.00 | 0.00 | 0.106589E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.491777E+09 | 0.00 | 0.00 | 0.00 | 0.180847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.583364E+09 | 0.00 | 0.00 | 0.00 | 0.216985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.612469E+09 | 0.00 | 0.00 | 0.00 | 0.227157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.354610E+09 | 0.00 | 0.00 | 0.00 | 0.127985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.100692E+09 | 0.00 | 0.00 | 0.00 | 0.356045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 23307456.47 | 0.00 | 0.00 | 0.00 | 20848655.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 80446248.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.294683E+10 | 0.00 | 0.00 | 0.00 | 0.954144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23307456.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.612469E+09 | 0.00 | 0.00 | 0.00 | 0.227157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 87663035.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 76912883.77 | 0.00 | 0.00 | 0.00 | 83201897.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 80406360.70 | 0.00 | 0.00 | 0.00 | 0.276964E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.182910E+09 | 0.00 | 0.00 | 0.00 | 0.643118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.323603E+09 | 0.00 | 0.00 | 0.00 | 0.115553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.496450E+09 | 0.00 | 0.00 | 0.00 | 0.182352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.594967E+09 | 0.00 | 0.00 | 0.00 | 0.221033E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.655247E+09 | 0.00 | 0.00 | 0.00 | 0.242640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.430087E+09 | 0.00 | 0.00 | 0.00 | 0.154798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198504E+09 | 0.00 | 0.00 | 0.00 | 0.699273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 60790124.21 | 0.00 | 0.00 | 0.00 | 0.195332E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42110859.29 | 0.00 | 0.00 | 0.00 | 29138224.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.322965E+10 | 0.00 | 0.00 | 0.00 | 0.110908E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42110859.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.655247E+09 | 0.00 | 0.00 | 0.00 | 0.242640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 87736225.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77203027.70 | 0.00 | 0.00 | 0.00 | 84349130.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 80586188.53 | 0.00 | 0.00 | 0.00 | 0.277636E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.183093E+09 | 0.00 | 0.00 | 0.00 | 0.643910E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.323898E+09 | 0.00 | 0.00 | 0.00 | 0.115686E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.496691E+09 | 0.00 | 0.00 | 0.00 | 0.182485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.595214E+09 | 0.00 | 0.00 | 0.00 | 0.221179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.655143E+09 | 0.00 | 0.00 | 0.00 | 0.242664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.430097E+09 | 0.00 | 0.00 | 0.00 | 0.154841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198765E+09 | 0.00 | 0.00 | 0.00 | 0.700350E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 60847241.51 | 0.00 | 0.00 | 0.00 | 0.195616E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 42164732.38 | 0.00 | 0.00 | 0.00 | 29262933.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.323144E+10 | 0.00 | 0.00 | 0.00 | 0.110997E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42164732.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.655143E+09 | 0.00 | 0.00 | 0.00 | 0.242664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.175072E+09 | 0.00 | 0.00 | 0.00 | 897838.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.127522E+09 | 0.00 | 0.00 | 0.00 | 42367617.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 76777358.83 | 0.00 | 0.00 | 0.00 | 0.138830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.108852E+09 | 0.00 | 0.00 | 0.00 | 0.337450E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.189440E+09 | 0.00 | 0.00 | 0.00 | 0.665374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.327555E+09 | 0.00 | 0.00 | 0.00 | 0.119329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.394032E+09 | 0.00 | 0.00 | 0.00 | 0.145139E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.434293E+09 | 0.00 | 0.00 | 0.00 | 0.159208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.238187E+09 | 0.00 | 0.00 | 0.00 | 0.848863E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.107694E+09 | 0.00 | 0.00 | 0.00 | 0.309203E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73330721.89 | 0.00 | 0.00 | 0.00 | 67283323.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122608E+09 | 0.00 | 0.00 | 0.00 | 10709813.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.237536E+10 | 0.00 | 0.00 | 0.00 | 0.665774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 73330721.89 | 0.00 | 0.00 | 0.00 | 897838.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.434293E+09 | 0.00 | 0.00 | 0.00 | 0.159208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.212161E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.141596E+09 | 0.00 | 0.00 | 0.00 | 9530636.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 65323944.64 | 0.00 | 0.00 | 0.00 | 66765009.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 88283359.75 | 0.00 | 0.00 | 0.00 | 0.257299E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.175942E+09 | 0.00 | 0.00 | 0.00 | 0.617872E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.324814E+09 | 0.00 | 0.00 | 0.00 | 0.118278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.388451E+09 | 0.00 | 0.00 | 0.00 | 0.143021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.411896E+09 | 0.00 | 0.00 | 0.00 | 0.150999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.198975E+09 | 0.00 | 0.00 | 0.00 | 0.710193E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 73527088.99 | 0.00 | 0.00 | 0.00 | 0.168738E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 75361017.82 | 0.00 | 0.00 | 0.00 | 9221320.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.151209E+09 | 0.00 | 0.00 | 0.00 | 149840.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.230754E+10 | 0.00 | 0.00 | 0.00 | 0.596274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 65323944.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.411896E+09 | 0.00 | 0.00 | 0.00 | 0.150999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.172915E+09 | 0.00 | 0.00 | 0.00 | 719246.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.124833E+09 | 0.00 | 0.00 | 0.00 | 40726531.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69056517.85 | 0.00 | 0.00 | 0.00 | 0.119570E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.103343E+09 | 0.00 | 0.00 | 0.00 | 0.326793E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.187234E+09 | 0.00 | 0.00 | 0.00 | 0.668853E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.324754E+09 | 0.00 | 0.00 | 0.00 | 0.120190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.390606E+09 | 0.00 | 0.00 | 0.00 | 0.146125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.425100E+09 | 0.00 | 0.00 | 0.00 | 0.158371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.234214E+09 | 0.00 | 0.00 | 0.00 | 0.848447E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.102806E+09 | 0.00 | 0.00 | 0.00 | 0.299715E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 68415428.91 | 0.00 | 0.00 | 0.00 | 57558652.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.119392E+09 | 0.00 | 0.00 | 0.00 | 8337413.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.232267E+10 | 0.00 | 0.00 | 0.00 | 0.661759E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 68415428.91 | 0.00 | 0.00 | 0.00 | 719246.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.425100E+09 | 0.00 | 0.00 | 0.00 | 0.158371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.209810E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.138005E+09 | 0.00 | 0.00 | 0.00 | 7148732.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 60151356.17 | 0.00 | 0.00 | 0.00 | 56051194.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 82647180.32 | 0.00 | 0.00 | 0.00 | 0.245614E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.174144E+09 | 0.00 | 0.00 | 0.00 | 0.621952E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.322133E+09 | 0.00 | 0.00 | 0.00 | 0.119170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.385124E+09 | 0.00 | 0.00 | 0.00 | 0.144018E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.403363E+09 | 0.00 | 0.00 | 0.00 | 0.150279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.195906E+09 | 0.00 | 0.00 | 0.00 | 0.710825E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 68629436.19 | 0.00 | 0.00 | 0.00 | 0.158458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 72185770.81 | 0.00 | 0.00 | 0.00 | 6452804.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.148577E+09 | 0.00 | 0.00 | 0.00 | 40290.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.226068E+10 | 0.00 | 0.00 | 0.00 | 0.594120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 60151356.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.403363E+09 | 0.00 | 0.00 | 0.00 | 0.150279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.149274E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95201538.72 | 0.00 | 0.00 | 0.00 | 4494924.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 40900887.88 | 0.00 | 0.00 | 0.00 | 48102236.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 65948374.21 | 0.00 | 0.00 | 0.00 | 0.202986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.146168E+09 | 0.00 | 0.00 | 0.00 | 0.517801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271528E+09 | 0.00 | 0.00 | 0.00 | 0.991579E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.326769E+09 | 0.00 | 0.00 | 0.00 | 0.120626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.344446E+09 | 0.00 | 0.00 | 0.00 | 0.126658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.171164E+09 | 0.00 | 0.00 | 0.00 | 0.613334E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 52226392.87 | 0.00 | 0.00 | 0.00 | 0.137994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 47927912.86 | 0.00 | 0.00 | 0.00 | 7054083.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101904E+09 | 0.00 | 0.00 | 0.00 | 42395.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.181346E+10 | 0.00 | 0.00 | 0.00 | 0.499622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40900887.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.344446E+09 | 0.00 | 0.00 | 0.00 | 0.126658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.149242E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95171519.66 | 0.00 | 0.00 | 0.00 | 4560497.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 40952423.36 | 0.00 | 0.00 | 0.00 | 48058504.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 66109203.83 | 0.00 | 0.00 | 0.00 | 0.203650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.146425E+09 | 0.00 | 0.00 | 0.00 | 0.518972E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271651E+09 | 0.00 | 0.00 | 0.00 | 0.992550E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.326812E+09 | 0.00 | 0.00 | 0.00 | 0.120706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.344282E+09 | 0.00 | 0.00 | 0.00 | 0.126668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.171243E+09 | 0.00 | 0.00 | 0.00 | 0.613957E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 52333351.45 | 0.00 | 0.00 | 0.00 | 0.138427E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 47935916.79 | 0.00 | 0.00 | 0.00 | 6997475.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101863E+09 | 0.00 | 0.00 | 0.00 | 39281.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.181402E+10 | 0.00 | 0.00 | 0.00 | 0.500095E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40952423.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.344282E+09 | 0.00 | 0.00 | 0.00 | 0.126668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.113665E+09 | 0.00 | 0.00 | 0.00 | 1291357.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82545058.18 | 0.00 | 0.00 | 0.00 | 37026225.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51503701.26 | 0.00 | 0.00 | 0.00 | 0.113234E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87289001.49 | 0.00 | 0.00 | 0.00 | 0.283916E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.159875E+09 | 0.00 | 0.00 | 0.00 | 0.566271E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.274266E+09 | 0.00 | 0.00 | 0.00 | 0.100213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.332509E+09 | 0.00 | 0.00 | 0.00 | 0.122813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.367008E+09 | 0.00 | 0.00 | 0.00 | 0.134971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.211005E+09 | 0.00 | 0.00 | 0.00 | 0.754876E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88760615.55 | 0.00 | 0.00 | 0.00 | 0.280800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 48187483.15 | 0.00 | 0.00 | 0.00 | 63855286.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 75914882.40 | 0.00 | 0.00 | 0.00 | 11492530.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.189253E+10 | 0.00 | 0.00 | 0.00 | 0.569273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48187483.15 | 0.00 | 0.00 | 0.00 | 1291357.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.367008E+09 | 0.00 | 0.00 | 0.00 | 0.134971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.113714E+09 | 0.00 | 0.00 | 0.00 | 1376681.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82647070.07 | 0.00 | 0.00 | 0.00 | 37451714.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51625868.74 | 0.00 | 0.00 | 0.00 | 0.113558E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87473091.65 | 0.00 | 0.00 | 0.00 | 0.284679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.160123E+09 | 0.00 | 0.00 | 0.00 | 0.567438E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.274398E+09 | 0.00 | 0.00 | 0.00 | 0.100314E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.332552E+09 | 0.00 | 0.00 | 0.00 | 0.122894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366821E+09 | 0.00 | 0.00 | 0.00 | 0.134976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.211024E+09 | 0.00 | 0.00 | 0.00 | 0.755353E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 89010176.39 | 0.00 | 0.00 | 0.00 | 0.281751E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 48281652.24 | 0.00 | 0.00 | 0.00 | 64168034.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 75943165.12 | 0.00 | 0.00 | 0.00 | 11595863.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.189361E+10 | 0.00 | 0.00 | 0.00 | 0.569921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48281652.24 | 0.00 | 0.00 | 0.00 | 1376681.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.366821E+09 | 0.00 | 0.00 | 0.00 | 0.134976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.214673E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118108E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.236366E+09 | 722960.63 | 46659.09 | 27510.39 | 134889.00 | 0.752703E+09 | 3190097.66 | 284.07 | 0.35 |
| March | 0.499144E+09 | 8835010.64 | 0.00 | 38518.62 | 1266939.56 | 0.176842E+09 | 8115759.22 | 0.00 | 0.35 |
| April | 0.409482E+09 | 30235387.77 | 0.00 | 146605.59 | 1731775.77 | 44677277.34 | 31346634.29 | 0.00 | 0.35 |
| May | 0.194121E+09 | 0.158750E+09 | 0.00 | 404255.06 | 107776.30 | 0.00 | 84697329.41 | 0.00 | 0.36 |
| June | 24734502.53 | 0.597545E+09 | 0.00 | 350540.07 | 0.00 | 0.00 | 53207681.56 | 0.00 | 0.36 |
| July | 1194198.15 | 0.934612E+09 | 0.00 | 119544.63 | 0.00 | 0.00 | 15919996.48 | 0.00 | 0.36 |
| August | 0.00 | 0.114746E+10 | 0.00 | 27121.34 | 0.00 | 0.00 | 1354351.28 | 0.00 | 0.36 |
| September | 25519410.89 | 0.467220E+09 | 0.00 | 728528.60 | 0.00 | 0.00 | 99159829.24 | 0.00 | 0.36 |
| October | 0.370968E+09 | 92757695.50 | 0.00 | 1289901.06 | 0.00 | 0.00 | 0.240654E+09 | 0.00 | 0.35 |
| November | 0.687830E+09 | 2342631.39 | 0.00 | 498237.24 | 0.00 | 64599668.89 | 0.111275E+09 | 0.00 | 0.35 |
| December | 0.544731E+09 | 0.00 | 0.00 | 16113.52 | 0.00 | 0.575705E+09 | 3206152.44 | 0.00 | 0.35 |
| Annual Sum or Average | 0.320876E+10 | 0.344048E+10 | 46659.09 | 3646876.12 | 3241380.64 | 0.279560E+10 | 0.652127E+09 | 284.07 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.687830E+09 | 0.114746E+10 | 46659.09 | 1289901.06 | 1731775.77 | 0.118108E+10 | 0.240654E+09 | 284.07 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 26443318.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136424E+10 | 0.00 | 0.00 | 0.35 |
| February | 91916531.56 | 0.00 | 45338.25 | 0.00 | 2787830.27 | 0.884322E+09 | 0.00 | 439.75 | 0.35 |
| March | 0.296392E+09 | 3718735.96 | 38010.08 | 1068.25 | 7219057.20 | 0.348538E+09 | 302562.88 | 289.34 | 0.35 |
| April | 0.370807E+09 | 20593372.90 | 0.00 | 71377.82 | 10352964.63 | 77622312.24 | 17241236.54 | 0.00 | 0.35 |
| May | 0.204288E+09 | 0.151111E+09 | 0.00 | 346697.92 | 102904.54 | 0.00 | 74656718.31 | 0.00 | 0.36 |
| June | 23315298.95 | 0.597325E+09 | 0.00 | 366598.68 | 0.00 | 0.00 | 54622154.72 | 0.00 | 0.36 |
| July | 1216034.81 | 0.931671E+09 | 0.00 | 116667.75 | 0.00 | 0.00 | 16029161.38 | 0.00 | 0.36 |
| August | 0.00 | 0.112389E+10 | 0.00 | 31242.93 | 0.00 | 0.00 | 1474326.39 | 0.00 | 0.36 |
| September | 35353857.87 | 0.440177E+09 | 0.00 | 602519.65 | 0.00 | 0.00 | 95731170.65 | 0.00 | 0.36 |
| October | 0.492029E+09 | 76993301.33 | 0.00 | 511330.54 | 112202.88 | 0.00 | 0.102246E+09 | 0.00 | 0.35 |
| November | 0.601087E+09 | 729088.60 | 0.00 | 32932.41 | 454934.53 | 0.190517E+09 | 11397944.56 | 0.00 | 0.35 |
| December | 0.193061E+09 | 0.00 | 0.00 | 0.00 | 339555.39 | 0.904016E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.233591E+10 | 0.334621E+10 | 83348.33 | 2080435.96 | 21369449.44 | 0.376925E+10 | 0.373701E+09 | 729.09 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.601087E+09 | 0.112389E+10 | 45338.25 | 602519.65 | 10352964.63 | 0.136424E+10 | 0.102246E+09 | 439.75 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.129034E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514124E+09 | 0.00 | 0.00 | 0.51 |
| February | 0.101594E+10 | 171532.83 | 0.00 | 69609.76 | 119517.78 | 0.320765E+09 | 20484848.09 | 0.00 | 0.51 |
| March | 0.100298E+10 | 4004808.02 | 0.00 | 205406.02 | 3302389.33 | 21052034.57 | 72237824.65 | 0.00 | 0.52 |
| April | 0.744681E+09 | 18245535.41 | 0.00 | 277344.81 | 3568847.26 | 46695.12 | 66351108.44 | 0.00 | 0.52 |
| May | 0.515313E+09 | 0.115558E+09 | 0.00 | 495035.64 | 18221967.88 | 0.00 | 46612314.65 | 0.00 | 0.53 |
| June | 0.328446E+09 | 0.398548E+09 | 0.00 | 542130.84 | 78036987.11 | 0.00 | 16481421.45 | 0.00 | 0.53 |
| July | 0.267992E+09 | 0.490957E+09 | 0.00 | 455693.17 | 0.116394E+09 | 0.00 | 5631655.85 | 0.00 | 0.53 |
| August | 0.217568E+09 | 0.629282E+09 | 0.00 | 530034.20 | 0.122961E+09 | 0.00 | 8046456.44 | 0.00 | 0.53 |
| September | 0.466480E+09 | 0.241416E+09 | 0.00 | 874777.46 | 31519587.89 | 0.00 | 30742048.28 | 0.00 | 0.53 |
| October | 0.949434E+09 | 77391563.92 | 0.00 | 961907.24 | 7451460.22 | 0.00 | 0.145139E+09 | 0.00 | 0.52 |
| November | 0.122233E+10 | 1474559.79 | 0.00 | 503486.20 | 523061.84 | 841711.93 | 0.131355E+09 | 0.00 | 0.52 |
| December | 0.150003E+10 | 4283.74 | 0.00 | 78995.02 | 0.00 | 71235390.56 | 17840859.47 | 0.00 | 0.51 |
| Annual Sum or Average | 0.952153E+10 | 0.197705E+10 | 0.00 | 4994420.37 | 0.382099E+09 | 0.928066E+09 | 0.560922E+09 | 0.00 | 0.52 |
| Minimum of Months | 0.217568E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 |
| Maximum of Months | 0.150003E+10 | 0.629282E+09 | 0.00 | 961907.24 | 0.122961E+09 | 0.514124E+09 | 0.145139E+09 | 0.00 | 0.53 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 25672212.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136494E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.103617E+09 | 0.00 | 45505.49 | 0.00 | 2573138.00 | 0.872425E+09 | 0.00 | 496.91 | 0.35 |
| March | 0.301423E+09 | 2665258.70 | 0.00 | 659.72 | 7956812.67 | 0.340959E+09 | 188317.73 | 0.00 | 0.35 |
| April | 0.376404E+09 | 20817409.45 | 0.00 | 64792.26 | 9842090.86 | 72369717.42 | 15904250.25 | 0.00 | 0.35 |
| May | 0.204940E+09 | 0.156818E+09 | 0.00 | 374401.11 | 4596.61 | 0.00 | 76310313.60 | 0.00 | 0.36 |
| June | 19697281.45 | 0.601990E+09 | 0.00 | 418270.55 | 0.00 | 0.00 | 58537615.78 | 0.00 | 0.36 |
| July | 1554329.90 | 0.940329E+09 | 0.00 | 110215.04 | 0.00 | 0.00 | 15722044.53 | 0.00 | 0.36 |
| August | 0.00 | 0.112505E+10 | 0.00 | 32937.92 | 0.00 | 0.00 | 1600631.69 | 0.00 | 0.36 |
| September | 34372117.74 | 0.441646E+09 | 0.00 | 621244.80 | 0.00 | 0.00 | 97041420.65 | 0.00 | 0.36 |
| October | 0.479998E+09 | 78567547.93 | 0.00 | 493240.27 | 0.00 | 0.00 | 0.116088E+09 | 0.00 | 0.35 |
| November | 0.610290E+09 | 574773.89 | 0.00 | 21776.94 | 489901.06 | 0.183871E+09 | 7915549.63 | 0.00 | 0.35 |
| December | 0.186701E+09 | 0.00 | 0.00 | 0.00 | 328632.37 | 0.909888E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.234467E+10 | 0.336846E+10 | 45505.49 | 2137538.61 | 21195171.57 | 0.374445E+10 | 0.389308E+09 | 496.91 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.610290E+09 | 0.112505E+10 | 45505.49 | 621244.80 | 9842090.86 | 0.136494E+10 | 0.116088E+09 | 496.91 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.118068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128190E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.236005E+09 | 0.00 | 0.00 | 0.00 | 2744220.22 | 0.751729E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.501737E+09 | 2946411.73 | 0.00 | 1684.06 | 7462825.00 | 0.162578E+09 | 536332.78 | 0.00 | 0.35 |
| April | 0.460650E+09 | 21534069.95 | 0.00 | 110125.93 | 10026940.82 | 1112296.05 | 30995756.33 | 0.00 | 0.35 |
| May | 0.156826E+09 | 0.154093E+09 | 0.00 | 515553.43 | 41635.86 | 0.00 | 0.124991E+09 | 0.00 | 0.36 |
| June | 3374234.68 | 0.602880E+09 | 0.00 | 432051.79 | 0.00 | 0.00 | 74143392.63 | 0.00 | 0.36 |
| July | 0.00 | 0.928130E+09 | 0.00 | 131266.69 | 0.00 | 0.00 | 13624279.93 | 0.00 | 0.36 |
| August | 0.00 | 0.111107E+10 | 0.00 | 31747.80 | 0.00 | 0.00 | 1314220.73 | 0.00 | 0.36 |
| September | 12663632.29 | 0.433824E+09 | 0.00 | 701484.04 | 0.00 | 0.00 | 0.116992E+09 | 0.00 | 0.36 |
| October | 0.447624E+09 | 79548339.54 | 0.00 | 577092.33 | 7303.01 | 0.00 | 0.173089E+09 | 0.00 | 0.35 |
| November | 0.757573E+09 | 628824.44 | 0.00 | 48870.86 | 498318.46 | 51269280.46 | 24286448.04 | 0.00 | 0.35 |
| December | 0.504068E+09 | 0.00 | 0.00 | 0.00 | 359120.80 | 0.605695E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.319859E+10 | 0.333466E+10 | 0.00 | 2549876.93 | 21140364.17 | 0.285428E+10 | 0.559973E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.757573E+09 | 0.111107E+10 | 0.00 | 701484.04 | 10026940.82 | 0.128190E+10 | 0.173089E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.118452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128152E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.236482E+09 | 0.00 | 0.00 | 0.00 | 2715901.15 | 0.751297E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.500934E+09 | 2939425.57 | 0.00 | 1622.15 | 7461582.93 | 0.163272E+09 | 466920.14 | 0.00 | 0.35 |
| April | 0.460323E+09 | 21627145.35 | 0.00 | 110289.25 | 9880983.58 | 1432666.85 | 30814441.70 | 0.00 | 0.35 |
| May | 0.156669E+09 | 0.154352E+09 | 0.00 | 517532.17 | 39144.25 | 0.00 | 0.125193E+09 | 0.00 | 0.36 |
| June | 3254426.35 | 0.603185E+09 | 0.00 | 432810.98 | 0.00 | 0.00 | 74249858.27 | 0.00 | 0.36 |
| July | 0.00 | 0.928647E+09 | 0.00 | 131025.25 | 0.00 | 0.00 | 13609227.05 | 0.00 | 0.36 |
| August | 0.00 | 0.111124E+10 | 0.00 | 31657.98 | 0.00 | 0.00 | 1321666.09 | 0.00 | 0.36 |
| September | 12762609.64 | 0.433981E+09 | 0.00 | 701293.49 | 0.00 | 0.00 | 0.116887E+09 | 0.00 | 0.36 |
| October | 0.446466E+09 | 79703678.17 | 0.00 | 580664.24 | 0.00 | 0.00 | 0.174214E+09 | 0.00 | 0.35 |
| November | 0.758090E+09 | 624927.10 | 0.00 | 47666.93 | 499814.60 | 50948973.66 | 24015453.86 | 0.00 | 0.35 |
| December | 0.503945E+09 | 0.00 | 0.00 | 0.00 | 358332.90 | 0.605802E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.319738E+10 | 0.333630E+10 | 0.00 | 2554562.44 | 20955759.41 | 0.285427E+10 | 0.560772E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.758090E+09 | 0.111124E+10 | 0.00 | 701293.49 | 9880983.58 | 0.128152E+10 | 0.174214E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.595185E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.813911E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.492548E+09 | 714101.55 | 0.00 | 38695.25 | 143887.20 | 0.513610E+09 | 6166385.90 | 0.00 | 0.35 |
| March | 0.675321E+09 | 9231544.83 | 0.00 | 78094.14 | 732783.02 | 28014788.12 | 23876702.60 | 0.00 | 0.35 |
| April | 0.449246E+09 | 33110417.73 | 0.00 | 236275.88 | 811797.66 | 0.00 | 69225816.14 | 0.00 | 0.35 |
| May | 0.146887E+09 | 0.163388E+09 | 0.00 | 609718.96 | 44399.86 | 0.00 | 0.132028E+09 | 0.00 | 0.36 |
| June | 4486500.20 | 0.604581E+09 | 0.00 | 415397.98 | 0.00 | 0.00 | 73029970.31 | 0.00 | 0.36 |
| July | 0.00 | 0.933666E+09 | 0.00 | 134094.08 | 0.00 | 0.00 | 13308656.74 | 0.00 | 0.36 |
| August | 0.00 | 0.114116E+10 | 0.00 | 28456.10 | 0.00 | 0.00 | 1173819.91 | 0.00 | 0.36 |
| September | 5740847.12 | 0.466543E+09 | 0.00 | 839034.23 | 0.00 | 0.00 | 0.116081E+09 | 0.00 | 0.36 |
| October | 0.284850E+09 | 96943590.93 | 0.00 | 1693989.65 | 0.00 | 0.00 | 0.348209E+09 | 0.00 | 0.36 |
| November | 0.678150E+09 | 2911664.09 | 0.00 | 818221.81 | 0.00 | 0.00 | 0.224366E+09 | 0.00 | 0.35 |
| December | 0.100600E+10 | 2759.16 | 0.00 | 34373.50 | 0.00 | 0.136989E+09 | 11424261.23 | 0.00 | 0.35 |
| Annual Sum or Average | 0.433842E+10 | 0.345225E+10 | 0.00 | 4926351.60 | 1732867.75 | 0.149252E+10 | 0.101889E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.100600E+10 | 0.114116E+10 | 0.00 | 1693989.65 | 811797.66 | 0.813911E+09 | 0.348209E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.500541E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.906903E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.451231E+09 | 714564.48 | 0.00 | 41787.32 | 142950.33 | 0.554719E+09 | 6489189.02 | 0.00 | 0.35 |
| March | 0.673932E+09 | 9631643.39 | 0.00 | 95830.75 | 533608.64 | 29692842.74 | 27409487.82 | 0.00 | 0.35 |
| April | 0.432908E+09 | 34307812.30 | 0.00 | 281270.45 | 568831.80 | 0.00 | 88243149.67 | 0.00 | 0.35 |
| May | 0.134642E+09 | 0.169734E+09 | 0.00 | 699911.46 | 19666.94 | 0.00 | 0.138397E+09 | 0.00 | 0.36 |
| June | 2436157.43 | 0.627648E+09 | 0.00 | 463474.77 | 0.00 | 0.00 | 73192247.07 | 0.00 | 0.36 |
| July | 0.00 | 0.969451E+09 | 0.00 | 135779.36 | 0.00 | 0.00 | 11260379.53 | 0.00 | 0.36 |
| August | 0.00 | 0.117979E+10 | 0.00 | 29944.04 | 0.00 | 0.00 | 938646.25 | 0.00 | 0.36 |
| September | 2254743.27 | 0.487431E+09 | 0.00 | 915435.59 | 0.00 | 0.00 | 0.115023E+09 | 0.00 | 0.36 |
| October | 0.265585E+09 | 0.100954E+09 | 0.00 | 1867571.92 | 0.00 | 0.00 | 0.366230E+09 | 0.00 | 0.36 |
| November | 0.661523E+09 | 3151551.75 | 0.00 | 893866.29 | 0.00 | 0.00 | 0.241784E+09 | 0.00 | 0.35 |
| December | 0.964536E+09 | 3251.33 | 0.00 | 38328.74 | 0.00 | 0.175093E+09 | 14062415.04 | 0.00 | 0.35 |
| Annual Sum or Average | 0.408959E+10 | 0.358281E+10 | 0.00 | 5463200.70 | 1265057.71 | 0.166641E+10 | 0.108303E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.964536E+09 | 0.117979E+10 | 0.00 | 1867571.92 | 568831.80 | 0.906903E+09 | 0.366230E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.802796E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199489E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.793307E+09 | 1515227.39 | 0.00 | 347638.78 | 40814.76 | 0.117876E+10 | 52867410.35 | 0.00 | 0.35 |
| March | 0.116218E+10 | 27645813.81 | 0.00 | 1211460.54 | 33871.66 | 0.112091E+09 | 0.216338E+09 | 0.00 | 0.35 |
| April | 0.624013E+09 | 89237706.30 | 0.00 | 2149558.65 | 1529.24 | 0.00 | 0.409271E+09 | 0.00 | 0.35 |
| May | 0.159786E+09 | 0.397110E+09 | 0.00 | 2416082.93 | 0.00 | 0.00 | 0.330190E+09 | 0.00 | 0.36 |
| June | 19049100.93 | 0.126651E+10 | 0.00 | 1005447.11 | 0.00 | 0.00 | 0.124680E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.191707E+10 | 0.00 | 266877.69 | 0.00 | 0.00 | 29528950.74 | 0.00 | 0.36 |
| August | 0.00 | 0.227694E+10 | 0.00 | 55986.42 | 0.00 | 0.00 | 2879427.50 | 0.00 | 0.36 |
| September | 87475788.12 | 0.907523E+09 | 0.00 | 1304149.17 | 0.00 | 0.00 | 0.165488E+09 | 0.00 | 0.36 |
| October | 0.834963E+09 | 0.174788E+09 | 0.00 | 2347711.68 | 0.00 | 15780719.11 | 0.336617E+09 | 0.00 | 0.35 |
| November | 0.129575E+10 | 4951451.40 | 0.00 | 973924.48 | 22281.01 | 0.209573E+09 | 0.185391E+09 | 0.00 | 0.35 |
| December | 0.105917E+10 | 13431.25 | 0.00 | 115560.62 | 0.00 | 0.116861E+10 | 25582255.56 | 0.00 | 0.35 |
| Annual Sum or Average | 0.683848E+10 | 0.706330E+10 | 0.00 | 12194398.06 | 98496.67 | 0.467970E+10 | 0.187883E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.129575E+10 | 0.227694E+10 | 0.00 | 2416082.93 | 40814.76 | 0.199489E+10 | 0.409271E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.211187E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256232E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.492037E+09 | 893145.44 | 12752.91 | 34963.47 | 1480806.87 | 0.147897E+10 | 4145363.62 | 3.28 | 0.35 |
| March | 0.110721E+10 | 23151428.65 | 0.00 | 320985.46 | 1212201.74 | 0.226008E+09 | 76407323.29 | 0.00 | 0.35 |
| April | 0.666516E+09 | 82750224.30 | 0.00 | 1529206.83 | 839476.71 | 4893430.71 | 0.343968E+09 | 0.00 | 0.35 |
| May | 0.172461E+09 | 0.385004E+09 | 0.00 | 2268828.41 | 0.00 | 0.00 | 0.323740E+09 | 0.00 | 0.36 |
| June | 14473473.16 | 0.126335E+10 | 0.00 | 1061708.80 | 0.00 | 0.00 | 0.129154E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.190800E+10 | 0.00 | 263226.51 | 0.00 | 0.00 | 30058327.04 | 0.00 | 0.36 |
| August | 0.00 | 0.222911E+10 | 0.00 | 65874.54 | 0.00 | 0.00 | 3082026.61 | 0.00 | 0.36 |
| September | 0.102349E+09 | 0.853355E+09 | 0.00 | 1105679.32 | 0.00 | 0.00 | 0.161718E+09 | 0.00 | 0.36 |
| October | 0.924295E+09 | 0.145092E+09 | 0.00 | 873429.87 | 437310.54 | 67649385.68 | 0.154378E+09 | 0.00 | 0.35 |
| November | 0.985750E+09 | 1925942.20 | 0.00 | 75073.86 | 826255.70 | 0.562899E+09 | 25153738.32 | 0.00 | 0.35 |
| December | 0.429450E+09 | 0.00 | 0.00 | 0.00 | 371817.50 | 0.176039E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.510573E+10 | 0.689263E+10 | 12752.91 | 7598977.07 | 5167869.06 | 0.666314E+10 | 0.125181E+10 | 3.28 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.110721E+10 | 0.222911E+10 | 12752.91 | 2268828.41 | 1480806.87 | 0.256232E+10 | 0.343968E+09 | 3.28 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.811033E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198605E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.811445E+09 | 1517495.75 | 10783.77 | 367183.12 | 32598.90 | 0.116359E+10 | 53485412.31 | 97.12 | 0.35 |
| March | 0.115872E+10 | 27010225.29 | 0.00 | 1109432.10 | 0.00 | 0.113372E+09 | 0.222340E+09 | 0.00 | 0.35 |
| April | 0.617873E+09 | 89649969.23 | 0.00 | 2188883.24 | 0.00 | 0.00 | 0.420838E+09 | 0.00 | 0.35 |
| May | 0.145144E+09 | 0.406623E+09 | 0.00 | 2586012.95 | 0.00 | 0.00 | 0.349415E+09 | 0.00 | 0.36 |
| June | 13811869.53 | 0.127525E+10 | 0.00 | 1130978.50 | 0.00 | 0.00 | 0.130650E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.193433E+10 | 0.00 | 259204.42 | 0.00 | 0.00 | 30055343.19 | 0.00 | 0.36 |
| August | 0.00 | 0.227968E+10 | 0.00 | 62696.46 | 0.00 | 0.00 | 3038746.64 | 0.00 | 0.36 |
| September | 84813723.63 | 0.909864E+09 | 0.00 | 1385827.52 | 0.00 | 0.00 | 0.169022E+09 | 0.00 | 0.36 |
| October | 0.807822E+09 | 0.176412E+09 | 0.00 | 2375199.91 | 0.00 | 23738339.20 | 0.357201E+09 | 0.00 | 0.35 |
| November | 0.129875E+10 | 4479958.01 | 0.00 | 884846.79 | 35487.10 | 0.207039E+09 | 0.188780E+09 | 0.00 | 0.35 |
| December | 0.108630E+10 | 12923.45 | 0.00 | 98286.52 | 0.00 | 0.114552E+10 | 21421370.64 | 0.00 | 0.35 |
| Annual Sum or Average | 0.683571E+10 | 0.710483E+10 | 10783.77 | 12448551.54 | 68086.00 | 0.463931E+10 | 0.194625E+10 | 97.12 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.129875E+10 | 0.227968E+10 | 10783.77 | 2586012.95 | 35487.10 | 0.198605E+10 | 0.420838E+09 | 97.12 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.171963E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260128E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.502899E+09 | 882697.58 | 12971.22 | 27156.83 | 1113808.91 | 0.147034E+10 | 3836258.86 | 29.56 | 0.35 |
| March | 0.114369E+10 | 22439088.32 | 0.00 | 255925.88 | 858508.88 | 0.208176E+09 | 56082129.36 | 0.00 | 0.35 |
| April | 0.682065E+09 | 83104259.92 | 0.00 | 1521923.37 | 802301.95 | 4334921.34 | 0.334814E+09 | 0.00 | 0.35 |
| May | 0.158490E+09 | 0.394605E+09 | 0.00 | 2439222.54 | 0.00 | 0.00 | 0.342540E+09 | 0.00 | 0.36 |
| June | 12791518.89 | 0.127118E+10 | 0.00 | 1178876.01 | 0.00 | 0.00 | 0.131508E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.192413E+10 | 0.00 | 252130.21 | 0.00 | 0.00 | 30584900.20 | 0.00 | 0.36 |
| August | 0.00 | 0.223135E+10 | 0.00 | 68737.55 | 0.00 | 0.00 | 3284189.03 | 0.00 | 0.36 |
| September | 98732774.25 | 0.856467E+09 | 0.00 | 1170612.79 | 0.00 | 0.00 | 0.166216E+09 | 0.00 | 0.36 |
| October | 0.920307E+09 | 0.148229E+09 | 0.00 | 789509.57 | 0.00 | 65625287.57 | 0.166049E+09 | 0.00 | 0.35 |
| November | 0.100558E+10 | 1560916.16 | 0.00 | 60736.72 | 920448.55 | 0.546068E+09 | 19823029.80 | 0.00 | 0.35 |
| December | 0.425993E+09 | 0.00 | 0.00 | 0.00 | 325639.83 | 0.176252E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.512251E+10 | 0.693395E+10 | 12971.22 | 7764831.47 | 4020708.13 | 0.665835E+10 | 0.125474E+10 | 29.56 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.114369E+10 | 0.223135E+10 | 12971.22 | 2439222.54 | 1113808.91 | 0.260128E+10 | 0.342540E+09 | 29.56 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.661669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213545E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.801625E+09 | 887136.92 | 0.00 | 30541.93 | 1393997.42 | 0.121208E+10 | 6872853.62 | 0.00 | 0.35 |
| March | 0.134914E+10 | 22573656.08 | 0.00 | 376331.67 | 1206251.67 | 10890063.81 | 0.115821E+09 | 0.00 | 0.35 |
| April | 0.565073E+09 | 83286820.67 | 0.00 | 1910397.19 | 1037731.30 | 0.00 | 0.477894E+09 | 0.00 | 0.35 |
| May | 78687064.82 | 0.376608E+09 | 0.00 | 2605120.91 | 0.00 | 0.00 | 0.407695E+09 | 0.00 | 0.36 |
| June | 343577.02 | 0.125832E+10 | 0.00 | 1118225.24 | 0.00 | 0.00 | 0.145366E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.188841E+10 | 0.00 | 292403.42 | 0.00 | 0.00 | 24706513.09 | 0.00 | 0.36 |
| August | 0.00 | 0.220558E+10 | 0.00 | 63076.50 | 0.00 | 0.00 | 2691440.65 | 0.00 | 0.36 |
| September | 47035219.50 | 0.849086E+09 | 0.00 | 1311495.39 | 0.00 | 0.00 | 0.213546E+09 | 0.00 | 0.36 |
| October | 0.936944E+09 | 0.154319E+09 | 0.00 | 1034053.52 | 14025.43 | 0.00 | 0.272158E+09 | 0.00 | 0.35 |
| November | 0.139192E+10 | 1867089.48 | 0.00 | 176737.02 | 814412.28 | 0.181306E+09 | 67509103.32 | 0.00 | 0.35 |
| December | 0.113337E+10 | 0.00 | 0.00 | 0.00 | 386504.74 | 0.109079E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.696581E+10 | 0.684094E+10 | 0.00 | 8918382.79 | 4852922.84 | 0.463052E+10 | 0.173426E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.139192E+10 | 0.220558E+10 | 0.00 | 2605120.91 | 1393997.42 | 0.213545E+10 | 0.477894E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.659544E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213759E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.799992E+09 | 885570.29 | 0.00 | 31472.87 | 1355930.55 | 0.121395E+10 | 6911750.55 | 0.00 | 0.35 |
| March | 0.134935E+10 | 22590794.96 | 0.00 | 374398.47 | 1191365.12 | 10890134.64 | 0.115481E+09 | 0.00 | 0.35 |
| April | 0.567033E+09 | 83332179.14 | 0.00 | 1906753.71 | 1020035.52 | 0.00 | 0.476244E+09 | 0.00 | 0.35 |
| May | 78717654.75 | 0.377087E+09 | 0.00 | 2608428.43 | 0.00 | 0.00 | 0.407826E+09 | 0.00 | 0.36 |
| June | 343783.31 | 0.125881E+10 | 0.00 | 1118796.43 | 0.00 | 0.00 | 0.145376E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.188925E+10 | 0.00 | 291713.09 | 0.00 | 0.00 | 24709318.67 | 0.00 | 0.36 |
| August | 0.00 | 0.220584E+10 | 0.00 | 63359.81 | 0.00 | 0.00 | 2704071.32 | 0.00 | 0.36 |
| September | 47079509.78 | 0.849374E+09 | 0.00 | 1311195.77 | 0.00 | 0.00 | 0.213512E+09 | 0.00 | 0.36 |
| October | 0.931857E+09 | 0.154612E+09 | 0.00 | 1043563.34 | 13258.98 | 0.00 | 0.277313E+09 | 0.00 | 0.35 |
| November | 0.139037E+10 | 1862508.65 | 0.00 | 175316.68 | 819924.17 | 0.182652E+09 | 67507964.26 | 0.00 | 0.35 |
| December | 0.113284E+10 | 0.00 | 0.00 | 0.00 | 384373.79 | 0.109128E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.695713E+10 | 0.684364E+10 | 0.00 | 8924998.59 | 4784888.14 | 0.463636E+10 | 0.173758E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.139037E+10 | 0.220584E+10 | 0.00 | 2608428.43 | 1355930.55 | 0.213759E+10 | 0.476244E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.174216E+10 | 0.00 | 0.00 | 178.02 | 0.00 | 0.110266E+10 | 666447.73 | 0.00 | 0.35 |
| February | 0.131142E+10 | 1493961.90 | 0.00 | 614687.87 | 39297.31 | 0.636279E+09 | 0.144029E+09 | 0.00 | 0.35 |
| March | 0.116380E+10 | 27978432.98 | 0.00 | 1643043.75 | 0.00 | 0.00 | 0.408771E+09 | 0.00 | 0.35 |
| April | 0.439850E+09 | 90400613.10 | 0.00 | 2735546.99 | 0.00 | 0.00 | 0.623334E+09 | 0.00 | 0.35 |
| May | 68108086.38 | 0.389454E+09 | 0.00 | 2806091.96 | 0.00 | 0.00 | 0.411237E+09 | 0.00 | 0.36 |
| June | 1963869.64 | 0.125957E+10 | 0.00 | 1067578.76 | 0.00 | 0.00 | 0.144178E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.189627E+10 | 0.00 | 290954.80 | 0.00 | 0.00 | 24140195.72 | 0.00 | 0.36 |
| August | 0.00 | 0.226012E+10 | 0.00 | 57612.19 | 0.00 | 0.00 | 2488651.72 | 0.00 | 0.36 |
| September | 35339804.97 | 0.910597E+09 | 0.00 | 1573417.60 | 0.00 | 0.00 | 0.212441E+09 | 0.00 | 0.36 |
| October | 0.660202E+09 | 0.185808E+09 | 0.00 | 3091695.22 | 0.00 | 0.00 | 0.583614E+09 | 0.00 | 0.35 |
| November | 0.133132E+10 | 6208251.17 | 0.00 | 1763206.93 | 0.00 | 21475504.20 | 0.428276E+09 | 0.00 | 0.35 |
| December | 0.188263E+10 | 78842.65 | 0.00 | 319388.35 | 0.00 | 0.351783E+09 | 94341961.43 | 0.00 | 0.35 |
| Annual Sum or Average | 0.863680E+10 | 0.702798E+10 | 0.00 | 15963402.45 | 39297.31 | 0.211219E+10 | 0.307752E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 178.02 | 0.00 | 0.00 | 666447.73 | 0.00 | 0.35 |
| Maximum of Months | 0.188263E+10 | 0.226012E+10 | 0.00 | 3091695.22 | 39297.31 | 0.110266E+10 | 0.623334E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.174098E+10 | 0.00 | 0.00 | 257.50 | 0.00 | 0.110391E+10 | 667552.41 | 0.00 | 0.35 |
| February | 0.130755E+10 | 1494364.28 | 0.00 | 626064.59 | 39181.40 | 0.637684E+09 | 0.146709E+09 | 0.00 | 0.35 |
| March | 0.116298E+10 | 28001502.74 | 0.00 | 1649272.48 | 0.00 | 0.00 | 0.409562E+09 | 0.00 | 0.35 |
| April | 0.436884E+09 | 90449606.43 | 0.00 | 2735762.40 | 0.00 | 0.00 | 0.626539E+09 | 0.00 | 0.35 |
| May | 68297139.87 | 0.389909E+09 | 0.00 | 2808341.43 | 0.00 | 0.00 | 0.411194E+09 | 0.00 | 0.36 |
| June | 1683433.06 | 0.126006E+10 | 0.00 | 1068220.05 | 0.00 | 0.00 | 0.144469E+09 | 0.00 | 0.36 |
| July | 0.00 | 0.189710E+10 | 0.00 | 288111.09 | 0.00 | 0.00 | 24147914.47 | 0.00 | 0.36 |
| August | 0.00 | 0.226036E+10 | 0.00 | 57484.94 | 0.00 | 0.00 | 2499844.69 | 0.00 | 0.36 |
| September | 35602837.56 | 0.910817E+09 | 0.00 | 1572838.13 | 0.00 | 0.00 | 0.212194E+09 | 0.00 | 0.36 |
| October | 0.660420E+09 | 0.185935E+09 | 0.00 | 3095096.94 | 0.00 | 0.00 | 0.583238E+09 | 0.00 | 0.35 |
| November | 0.133235E+10 | 6200356.83 | 0.00 | 1764652.96 | 0.00 | 21475503.66 | 0.427454E+09 | 0.00 | 0.35 |
| December | 0.188214E+10 | 79441.05 | 0.00 | 320709.68 | 0.00 | 0.352095E+09 | 94671109.86 | 0.00 | 0.35 |
| Annual Sum or Average | 0.862888E+10 | 0.703041E+10 | 0.00 | 15986812.18 | 39181.40 | 0.211516E+10 | 0.308335E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 257.50 | 0.00 | 0.00 | 667552.41 | 0.00 | 0.35 |
| Maximum of Months | 0.188214E+10 | 0.226036E+10 | 0.00 | 3095096.94 | 39181.40 | 0.110391E+10 | 0.626539E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.161634E+09 | 0.00 | 0.00 | 26528.69 | 0.00 | 0.121920E+10 | 10113940.15 | 0.00 | 0.35 |
| February | 0.168184E+09 | 773961.71 | 11360.39 | 213440.92 | 8825.42 | 0.802178E+09 | 17735124.10 | 667.13 | 0.35 |
| March | 0.282368E+09 | 13876596.59 | 0.00 | 546585.59 | 61934.20 | 0.336677E+09 | 66895416.31 | 0.00 | 0.35 |
| April | 0.284416E+09 | 42835031.04 | 0.00 | 625202.98 | 51871.32 | 0.108187E+09 | 75588032.28 | 0.00 | 0.35 |
| May | 0.160391E+09 | 0.195905E+09 | 0.00 | 642444.97 | 218504.26 | 13951633.35 | 74010888.18 | 0.00 | 0.36 |
| June | 44946550.24 | 0.610018E+09 | 0.00 | 320167.13 | 21115.46 | 0.00 | 29439441.55 | 0.00 | 0.36 |
| July | 10874005.75 | 0.924393E+09 | 0.00 | 115855.95 | 0.00 | 0.00 | 13025334.26 | 0.00 | 0.36 |
| August | 1588193.86 | 0.109765E+10 | 0.00 | 61773.90 | 0.00 | 0.00 | 2605405.46 | 0.00 | 0.36 |
| September | 94802062.16 | 0.422005E+09 | 0.00 | 336057.78 | 0.00 | 170078.20 | 36171381.69 | 0.00 | 0.36 |
| October | 0.271885E+09 | 79378913.64 | 0.00 | 836097.12 | 133341.27 | 0.193525E+09 | 70010812.89 | 0.00 | 0.35 |
| November | 0.292285E+09 | 2326185.10 | 0.00 | 461053.38 | 94056.74 | 0.446934E+09 | 47633604.62 | 0.00 | 0.35 |
| December | 0.204900E+09 | 7720.52 | 0.00 | 102955.65 | 0.00 | 0.882557E+09 | 18610774.70 | 0.00 | 0.35 |
| Annual Sum or Average | 0.197827E+10 | 0.338917E+10 | 11360.39 | 4288164.06 | 589648.67 | 0.400338E+10 | 0.461840E+09 | 667.13 | 0.35 |
| Minimum of Months | 1588193.86 | 0.00 | 0.00 | 26528.69 | 0.00 | 0.00 | 2605405.46 | 0.00 | 0.35 |
| Maximum of Months | 0.292285E+09 | 0.109765E+10 | 11360.39 | 836097.12 | 218504.26 | 0.121920E+10 | 75588032.28 | 667.13 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 31791888.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134864E+10 | 0.00 | 0.00 | 0.35 |
| February | 80504329.61 | 640995.90 | 9821.30 | 39752.91 | 423026.22 | 0.890265E+09 | 3088369.42 | 535.11 | 0.35 |
| March | 0.236878E+09 | 12335776.80 | 19457.52 | 125225.89 | 516030.81 | 0.405424E+09 | 19265502.72 | 171.56 | 0.35 |
| April | 0.271800E+09 | 40222912.24 | 0.00 | 420257.09 | 351692.09 | 0.131282E+09 | 56440457.14 | 0.00 | 0.35 |
| May | 0.164097E+09 | 0.190867E+09 | 0.00 | 584254.24 | 178834.10 | 14054072.01 | 70792431.86 | 0.00 | 0.36 |
| June | 44526892.47 | 0.610485E+09 | 0.00 | 339501.53 | 1780.51 | 0.00 | 29923883.44 | 0.00 | 0.36 |
| July | 11257750.45 | 0.923535E+09 | 0.00 | 117027.36 | 0.00 | 0.00 | 12447264.20 | 0.00 | 0.36 |
| August | 1554442.02 | 0.107979E+10 | 0.00 | 62697.21 | 0.00 | 0.00 | 3013168.84 | 0.00 | 0.36 |
| September | 98652570.06 | 0.398742E+09 | 0.00 | 280904.05 | 57423.53 | 342160.68 | 33846781.12 | 0.00 | 0.36 |
| October | 0.226791E+09 | 65629268.39 | 0.00 | 260763.72 | 1608189.65 | 0.256590E+09 | 31391635.18 | 0.00 | 0.35 |
| November | 0.188115E+09 | 862260.04 | 4530.58 | 38754.14 | 274558.05 | 0.560058E+09 | 5756179.13 | 151.59 | 0.35 |
| December | 58387417.41 | 0.00 | 0.00 | 1958.29 | 170880.24 | 0.102620E+10 | 650565.87 | 0.00 | 0.35 |
| Annual Sum or Average | 0.141436E+10 | 0.332311E+10 | 33809.40 | 2271096.44 | 3582415.20 | 0.463286E+10 | 0.266616E+09 | 858.26 | 0.35 |
| Minimum of Months | 1554442.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.271800E+09 | 0.107979E+10 | 19457.52 | 584254.24 | 1608189.65 | 0.134864E+10 | 70792431.86 | 535.11 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.159282E+09 | 0.00 | 0.00 | 12850.29 | 0.00 | 0.122460E+10 | 6068120.74 | 0.00 | 0.35 |
| February | 0.169339E+09 | 775257.99 | 11459.87 | 195318.47 | 4122.41 | 0.802267E+09 | 17734183.18 | 717.33 | 0.35 |
| March | 0.297882E+09 | 13466105.96 | 0.00 | 448184.83 | 0.00 | 0.327089E+09 | 62129469.35 | 0.00 | 0.35 |
| April | 0.300010E+09 | 43076136.84 | 0.00 | 579962.46 | 30767.14 | 0.101655E+09 | 69232358.62 | 0.00 | 0.35 |
| May | 0.166170E+09 | 0.201751E+09 | 0.00 | 672168.90 | 0.00 | 12158168.83 | 73519539.13 | 0.00 | 0.36 |
| June | 45184739.12 | 0.615586E+09 | 0.00 | 371019.08 | 0.00 | 0.00 | 30631727.04 | 0.00 | 0.36 |
| July | 11576748.06 | 0.934794E+09 | 0.00 | 117792.16 | 0.00 | 0.00 | 12515359.24 | 0.00 | 0.36 |
| August | 1535887.26 | 0.110036E+10 | 0.00 | 65418.37 | 0.00 | 0.00 | 2836412.12 | 0.00 | 0.36 |
| September | 94730555.01 | 0.424183E+09 | 0.00 | 367497.09 | 0.00 | 170077.84 | 37651383.41 | 0.00 | 0.36 |
| October | 0.281535E+09 | 80478641.05 | 0.00 | 740293.26 | 0.00 | 0.186223E+09 | 71023510.13 | 0.00 | 0.35 |
| November | 0.304522E+09 | 2066718.28 | 0.00 | 375030.76 | 101806.48 | 0.438605E+09 | 44906921.16 | 0.00 | 0.35 |
| December | 0.216952E+09 | 7849.13 | 0.00 | 68384.86 | 0.00 | 0.874943E+09 | 13641134.08 | 0.00 | 0.35 |
| Annual Sum or Average | 0.204872E+10 | 0.341654E+10 | 11459.87 | 4013920.54 | 136696.04 | 0.396771E+10 | 0.441890E+09 | 717.33 | 0.35 |
| Minimum of Months | 1535887.26 | 0.00 | 0.00 | 12850.29 | 0.00 | 0.00 | 2836412.12 | 0.00 | 0.35 |
| Maximum of Months | 0.304522E+09 | 0.110036E+10 | 11459.87 | 740293.26 | 101806.48 | 0.122460E+10 | 73519539.13 | 717.33 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 29718263.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135040E+10 | 0.00 | 0.00 | 0.35 |
| February | 83760414.24 | 715265.73 | 9920.40 | 24704.74 | 74298.81 | 0.887163E+09 | 2689634.12 | 738.87 | 0.35 |
| March | 0.243004E+09 | 11946353.84 | 0.00 | 94296.23 | 135561.67 | 0.402438E+09 | 12715746.79 | 0.00 | 0.35 |
| April | 0.287392E+09 | 40576726.30 | 0.00 | 376120.20 | 119077.88 | 0.122641E+09 | 51910899.23 | 0.00 | 0.35 |
| May | 0.170625E+09 | 0.197011E+09 | 0.00 | 615727.15 | 0.00 | 12165378.83 | 69643238.80 | 0.00 | 0.36 |
| June | 44749983.40 | 0.615843E+09 | 0.00 | 385749.98 | 0.00 | 0.00 | 31040818.98 | 0.00 | 0.36 |
| July | 11850112.13 | 0.933602E+09 | 0.00 | 119173.40 | 0.00 | 0.00 | 12068413.84 | 0.00 | 0.36 |
| August | 1498156.71 | 0.108276E+10 | 0.00 | 67711.10 | 0.00 | 0.00 | 3261976.18 | 0.00 | 0.36 |
| September | 99733016.85 | 0.401876E+09 | 0.00 | 301421.34 | 0.00 | 342159.70 | 34291882.11 | 0.00 | 0.36 |
| October | 0.243048E+09 | 67232257.03 | 0.00 | 176129.89 | 597213.14 | 0.248644E+09 | 25282111.38 | 0.00 | 0.35 |
| November | 0.189533E+09 | 630187.61 | 4590.95 | 26856.89 | 321928.65 | 0.557117E+09 | 4130657.49 | 161.13 | 0.35 |
| December | 47495030.29 | 0.00 | 0.00 | 973.06 | 136521.81 | 0.103666E+10 | 349158.77 | 0.00 | 0.35 |
| Annual Sum or Average | 0.145241E+10 | 0.335220E+10 | 14511.34 | 2188863.97 | 1384601.95 | 0.461757E+10 | 0.247385E+09 | 900.00 | 0.35 |
| Minimum of Months | 1498156.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.287392E+09 | 0.108276E+10 | 9920.40 | 615727.15 | 597213.14 | 0.135040E+10 | 69643238.80 | 738.87 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 55292816.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133549E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.155922E+09 | 612758.78 | 33192.31 | 18751.58 | 407160.47 | 0.826651E+09 | 2328731.82 | 556.99 | 0.35 |
| March | 0.335108E+09 | 11907616.80 | 5946.97 | 89468.56 | 726654.69 | 0.321310E+09 | 17577371.24 | 208.71 | 0.35 |
| April | 0.316032E+09 | 39383996.81 | 0.00 | 385293.73 | 366763.82 | 83561234.95 | 78461508.46 | 0.00 | 0.35 |
| May | 0.162866E+09 | 0.188958E+09 | 0.00 | 610638.22 | 157101.98 | 0.00 | 92865737.74 | 0.00 | 0.36 |
| June | 40461651.74 | 0.620146E+09 | 0.00 | 330970.35 | 0.00 | 0.00 | 34974991.60 | 0.00 | 0.36 |
| July | 4561160.95 | 0.932533E+09 | 0.00 | 111489.31 | 0.00 | 0.00 | 15980394.94 | 0.00 | 0.36 |
| August | 1122821.72 | 0.108962E+10 | 0.00 | 54183.74 | 0.00 | 0.00 | 2134781.33 | 0.00 | 0.36 |
| September | 94509932.18 | 0.403097E+09 | 0.00 | 310174.89 | 0.00 | 0.00 | 42770194.64 | 0.00 | 0.36 |
| October | 0.339874E+09 | 67480320.08 | 0.00 | 176036.92 | 1420050.47 | 0.160013E+09 | 30408523.25 | 0.00 | 0.35 |
| November | 0.269431E+09 | 643710.68 | 1929.13 | 36029.42 | 396522.75 | 0.489584E+09 | 8476348.80 | 75.29 | 0.35 |
| December | 0.115587E+09 | 0.00 | 0.00 | 1121.05 | 230944.35 | 0.980636E+09 | 431650.32 | 0.00 | 0.35 |
| Annual Sum or Average | 0.189077E+10 | 0.335438E+10 | 41068.41 | 2124157.76 | 3705198.53 | 0.419724E+10 | 0.326410E+09 | 840.99 | 0.35 |
| Minimum of Months | 1122821.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.339874E+09 | 0.108962E+10 | 33192.31 | 610638.22 | 1420050.47 | 0.133549E+10 | 92865737.74 | 556.99 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 55590032.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133518E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.156246E+09 | 620973.92 | 33200.21 | 18755.32 | 371295.21 | 0.826352E+09 | 2331156.18 | 561.08 | 0.35 |
| March | 0.334403E+09 | 11961651.50 | 5934.06 | 89533.94 | 646056.89 | 0.322055E+09 | 17313409.82 | 186.74 | 0.35 |
| April | 0.317034E+09 | 39465204.72 | 0.00 | 383898.14 | 335254.04 | 83327659.54 | 77665159.55 | 0.00 | 0.35 |
| May | 0.163253E+09 | 0.189436E+09 | 0.00 | 611505.34 | 143313.64 | 0.00 | 92620184.01 | 0.00 | 0.36 |
| June | 40191607.30 | 0.620534E+09 | 0.00 | 332435.01 | 0.00 | 0.00 | 35293854.66 | 0.00 | 0.36 |
| July | 4560148.97 | 0.933128E+09 | 0.00 | 110922.06 | 0.00 | 0.00 | 15995015.10 | 0.00 | 0.36 |
| August | 1298154.36 | 0.108987E+10 | 0.00 | 54183.96 | 0.00 | 0.00 | 1972827.51 | 0.00 | 0.36 |
| September | 94606818.16 | 0.403399E+09 | 0.00 | 311252.83 | 0.00 | 0.00 | 42689710.11 | 0.00 | 0.36 |
| October | 0.338970E+09 | 67732503.13 | 0.00 | 176390.81 | 1345624.56 | 0.160767E+09 | 30666002.76 | 0.00 | 0.35 |
| November | 0.268078E+09 | 640922.73 | 1956.87 | 35791.86 | 399046.38 | 0.490748E+09 | 8428511.53 | 78.19 | 0.35 |
| December | 0.114651E+09 | 0.00 | 0.00 | 1073.53 | 228252.69 | 0.981535E+09 | 431785.68 | 0.00 | 0.35 |
| Annual Sum or Average | 0.188888E+10 | 0.335679E+10 | 41091.14 | 2125742.82 | 3468843.42 | 0.419996E+10 | 0.325408E+09 | 826.01 | 0.35 |
| Minimum of Months | 1298154.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.338970E+09 | 0.108987E+10 | 33200.21 | 611505.34 | 1345624.56 | 0.133518E+10 | 92620184.01 | 561.08 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.301894E+09 | 0.00 | 0.00 | 30341.56 | 0.00 | 0.109085E+10 | 12884926.31 | 0.00 | 0.35 |
| February | 0.298607E+09 | 756411.68 | 35250.53 | 198268.50 | 4388.40 | 0.682088E+09 | 25192955.51 | 828.55 | 0.35 |
| March | 0.406172E+09 | 13868567.61 | 0.00 | 473964.67 | 58421.79 | 0.219178E+09 | 83720602.38 | 0.00 | 0.35 |
| April | 0.324591E+09 | 42554973.70 | 0.00 | 601413.08 | 26030.83 | 68436410.22 | 96616697.76 | 0.00 | 0.35 |
| May | 0.158339E+09 | 0.195126E+09 | 0.00 | 674434.28 | 173955.35 | 0.00 | 96132685.20 | 0.00 | 0.36 |
| June | 40656159.97 | 0.619976E+09 | 0.00 | 317204.70 | 2043.16 | 0.00 | 34746321.40 | 0.00 | 0.36 |
| July | 3713478.18 | 0.934158E+09 | 0.00 | 116025.65 | 0.00 | 0.00 | 16775858.78 | 0.00 | 0.36 |
| August | 879379.47 | 0.111178E+10 | 0.00 | 43601.60 | 0.00 | 0.00 | 2097790.77 | 0.00 | 0.36 |
| September | 87411225.05 | 0.431155E+09 | 0.00 | 380272.62 | 0.00 | 0.00 | 47095223.89 | 0.00 | 0.36 |
| October | 0.370653E+09 | 84044765.94 | 0.00 | 772819.15 | 25803.07 | 98597261.63 | 89028137.76 | 0.00 | 0.35 |
| November | 0.401816E+09 | 2270152.32 | 0.00 | 469420.50 | 107958.81 | 0.340483E+09 | 71215788.68 | 0.00 | 0.35 |
| December | 0.335803E+09 | 14674.32 | 0.00 | 117461.17 | 0.00 | 0.759158E+09 | 31843234.04 | 0.00 | 0.35 |
| Annual Sum or Average | 0.273054E+10 | 0.343571E+10 | 35250.53 | 4195227.47 | 398601.41 | 0.325879E+10 | 0.607350E+09 | 828.55 | 0.35 |
| Minimum of Months | 879379.47 | 0.00 | 0.00 | 30341.56 | 0.00 | 0.00 | 2097790.77 | 0.00 | 0.35 |
| Maximum of Months | 0.406172E+09 | 0.111178E+10 | 35250.53 | 772819.15 | 173955.35 | 0.109085E+10 | 96616697.76 | 828.55 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.303247E+09 | 0.00 | 0.00 | 29849.22 | 0.00 | 0.108982E+10 | 12578199.52 | 0.00 | 0.35 |
| February | 0.298615E+09 | 756722.23 | 35258.18 | 200616.33 | 4185.33 | 0.681704E+09 | 25690492.57 | 834.36 | 0.35 |
| March | 0.405997E+09 | 13877822.71 | 0.00 | 475683.13 | 48652.64 | 0.219661E+09 | 83415147.68 | 0.00 | 0.35 |
| April | 0.324349E+09 | 42620242.39 | 0.00 | 601997.94 | 26367.48 | 68433566.27 | 96838623.66 | 0.00 | 0.35 |
| May | 0.158690E+09 | 0.195580E+09 | 0.00 | 675816.90 | 162485.68 | 0.00 | 95904822.81 | 0.00 | 0.36 |
| June | 40597280.60 | 0.620368E+09 | 0.00 | 318239.94 | 1835.31 | 0.00 | 34855872.60 | 0.00 | 0.36 |
| July | 3765926.72 | 0.934751E+09 | 0.00 | 115475.36 | 0.00 | 0.00 | 16738196.66 | 0.00 | 0.36 |
| August | 1031755.76 | 0.111201E+10 | 0.00 | 43716.05 | 0.00 | 0.00 | 1956123.47 | 0.00 | 0.36 |
| September | 87194622.43 | 0.431385E+09 | 0.00 | 380153.49 | 0.00 | 0.00 | 47325002.48 | 0.00 | 0.36 |
| October | 0.370069E+09 | 84191477.74 | 0.00 | 776439.34 | 24367.48 | 98978918.09 | 89273963.38 | 0.00 | 0.35 |
| November | 0.401608E+09 | 2269013.56 | 0.00 | 470548.24 | 108079.25 | 0.340922E+09 | 71011718.97 | 0.00 | 0.35 |
| December | 0.335215E+09 | 15263.95 | 0.00 | 118471.43 | 0.00 | 0.759731E+09 | 31892843.16 | 0.00 | 0.35 |
| Annual Sum or Average | 0.273038E+10 | 0.343782E+10 | 35258.18 | 4207007.37 | 375973.17 | 0.325925E+10 | 0.607481E+09 | 834.36 | 0.35 |
| Minimum of Months | 1031755.76 | 0.00 | 0.00 | 29849.22 | 0.00 | 0.00 | 1956123.47 | 0.00 | 0.35 |
| Maximum of Months | 0.405997E+09 | 0.111201E+10 | 35258.18 | 776439.34 | 162485.68 | 0.108982E+10 | 96838623.66 | 834.36 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:14:20
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.103114E+12 | 0.291470E+11 | 0.00 | 0.180413E+10 | 0.180018E+11 |
| February | 0.969892E+11 | 0.246860E+11 | 0.00 | 0.135697E+10 | 0.139610E+11 |
| March | 0.133591E+12 | 0.184059E+11 | 0.00 | 0.108917E+10 | 0.136872E+11 |
| April | 0.143288E+12 | 0.113186E+11 | 0.00 | 0.789541E+09 | 0.368618E+11 |
| May | 0.154520E+12 | 0.532451E+10 | 0.00 | 0.428641E+09 | 0.826731E+11 |
| June | 0.148077E+12 | -0.604943E+10 | 0.00 | -131116298.5 | 0.151160E+12 |
| July | 0.144407E+12 | -0.912833E+10 | 0.00 | -333272816.9 | 0.185569E+12 |
| August | 0.136708E+12 | -0.122311E+11 | 0.00 | -526098684.6 | 0.203101E+12 |
| September | 0.110475E+12 | -3687912.2 | 0.00 | 0.225161E+09 | 0.116783E+12 |
| October | 0.110820E+12 | 0.125862E+11 | 0.00 | 0.101069E+10 | 0.409320E+11 |
| November | 0.841111E+11 | 0.183746E+11 | 0.00 | 0.135303E+10 | 0.999310E+10 |
| December | 0.840699E+11 | 0.246943E+11 | 0.00 | 0.158918E+10 | 0.111570E+11 |
| Annual Sum or Average | 0.145017E+13 | 0.117125E+12 | 0.00 | 0.865603E+10 | 0.883881E+12 |
| Minimum of Months | 0.840699E+11 | -0.122311E+11 | 0.00 | -526098684.6 | 0.999310E+10 |
| Maximum of Months | 0.154520E+12 | 0.291470E+11 | 0.00 | 0.180413E+10 | 0.203101E+12 |