Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:16
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Simulation Timestamp: 2023-10-16 09:16:53
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1449.63 | 462.46 | 513.33 |
| Net Site Energy | 1449.63 | 462.46 | 513.33 |
| Total Source Energy | 4536.60 | 1447.26 | 1606.46 |
| Net Source Energy | 4536.60 | 1447.26 | 1606.46 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 26.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 307.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 130.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 377.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1423.52 | 26.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 26.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 307.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 50.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 130.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 377.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 26.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 307.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 50.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 130.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 377.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 288.81 | 9.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 504.08 | 9.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 260.19 | 8.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 454.13 | 8.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1423.520 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1423.520 | 100.00 |
| Total On-Site and Utility Electric Sources | 1423.520 | 100.00 |
| Total Electricity End Uses | 1423.520 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 58.71 |
| Air to Air Heat Recovery for Heating | 0.00 | 41.29 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.17 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8629.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_FL_TAMPA
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:16 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Tampa-MacDill AFB FL USA TMY3 WMO#=747880 |
| Latitude [deg] | 27.85 |
| Longitude [deg] | -82.5 |
| Elevation [m] | 8.00 |
| Time Zone | -5.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 09-SEP-17:30 | 05-FEB-07:19 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 50436.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 31556.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 5231.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22609.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 8897.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 29135.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 97430.93 | 50436.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 50436.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 31556.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4887.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 344.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18441.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 8897.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 29135.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 28.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 974.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 412.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1195.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 4508.29 | 28.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 10.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 345.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 56.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 146.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 423.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1596.43 | 10.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 9.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 310.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 381.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1438.23 | 9.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.354086 |
| SPLIT GNW SUPPLY FAN | 0.338807 |
| SPLIT OFFICE SUPPLY FAN | 0.392321 |
| SPLIT GNE SUPPLY FAN | 0.315660 |
| SPLIT GN1 SUPPLY FAN | 0.282965 |
| SPLIT GN2 SUPPLY FAN | 0.282551 |
| SPLIT GS1 SUPPLY FAN | 0.299996 |
| SPLIT GS2 SUPPLY FAN | 0.302213 |
| SPLIT MSW SUPPLY FAN | 0.791266 |
| SPLIT MNW SUPPLY FAN | 0.759189 |
| SPLIT MSE SUPPLY FAN | 0.729840 |
| SPLIT MNE SUPPLY FAN | 0.698204 |
| SPLIT MN1 SUPPLY FAN | 0.626779 |
| SPLIT MN2 SUPPLY FAN | 0.625750 |
| SPLIT MS1 SUPPLY FAN | 0.662300 |
| SPLIT MS2 SUPPLY FAN | 0.661230 |
| SPLIT TSW SUPPLY FAN | 0.441412 |
| SPLIT TNW SUPPLY FAN | 0.428825 |
| SPLIT TSE SUPPLY FAN | 0.394443 |
| SPLIT TNE SUPPLY FAN | 0.381856 |
| SPLIT TN1 SUPPLY FAN | 0.353952 |
| SPLIT TN2 SUPPLY FAN | 0.352453 |
| SPLIT TS1 SUPPLY FAN | 0.367495 |
| SPLIT TS2 SUPPLY FAN | 0.366004 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.354086 |
| G NW APARTMENT DIRECT AIR | 0.338807 |
| OFFICE DIRECT AIR | 0.392321 |
| G NE APARTMENT DIRECT AIR | 0.315660 |
| G N1 APARTMENT DIRECT AIR | 0.282965 |
| G N2 APARTMENT DIRECT AIR | 0.282551 |
| G S1 APARTMENT DIRECT AIR | 0.299996 |
| G S2 APARTMENT DIRECT AIR | 0.302213 |
| M SW APARTMENT DIRECT AIR | 0.791266 |
| M NW APARTMENT DIRECT AIR | 0.759189 |
| M SE APARTMENT DIRECT AIR | 0.729840 |
| M NE APARTMENT DIRECT AIR | 0.698204 |
| M N1 APARTMENT DIRECT AIR | 0.626779 |
| M N2 APARTMENT DIRECT AIR | 0.625750 |
| M S1 APARTMENT DIRECT AIR | 0.662300 |
| M S2 APARTMENT DIRECT AIR | 0.661230 |
| T SW APARTMENT DIRECT AIR | 0.441412 |
| T NW APARTMENT DIRECT AIR | 0.428825 |
| T SE APARTMENT DIRECT AIR | 0.394443 |
| T NE APARTMENT DIRECT AIR | 0.381856 |
| T N1 APARTMENT DIRECT AIR | 0.353952 |
| T N2 APARTMENT DIRECT AIR | 0.352453 |
| T S1 APARTMENT DIRECT AIR | 0.367495 |
| T S2 APARTMENT DIRECT AIR | 0.366004 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.354086 | 0.354086 | 0.354086 | 0.354086 | 0.354086 | 0.354086 | 1.00 | 1.00 | 0.354086 |
| SPLIT GNW | 0.338807 | 0.338807 | 0.338807 | 0.338807 | 0.338807 | 0.338807 | 1.00 | 1.00 | 0.338807 |
| SPLIT OFFICE | 0.392321 | 0.392321 | 0.392321 | 0.392321 | 0.392321 | 0.392321 | 1.00 | 1.00 | 0.392321 |
| SPLIT GNE | 0.315660 | 0.315660 | 0.315660 | 0.315660 | 0.315660 | 0.315660 | 1.00 | 1.00 | 0.315660 |
| SPLIT GN1 | 0.282965 | 0.282965 | 0.282965 | 0.282965 | 0.282965 | 0.282965 | 1.00 | 1.00 | 0.282965 |
| SPLIT GN2 | 0.282551 | 0.282551 | 0.282551 | 0.282551 | 0.282551 | 0.282551 | 1.00 | 1.00 | 0.282551 |
| SPLIT GS1 | 0.299996 | 0.299996 | 0.299996 | 0.299996 | 0.299996 | 0.299996 | 1.00 | 1.00 | 0.299996 |
| SPLIT GS2 | 0.302213 | 0.302213 | 0.302213 | 0.302213 | 0.302213 | 0.302213 | 1.00 | 1.00 | 0.302213 |
| SPLIT MSW | 0.791266 | 0.791266 | 0.791266 | 0.791266 | 0.791266 | 0.791266 | 1.00 | 1.00 | 0.791266 |
| SPLIT MNW | 0.759189 | 0.759189 | 0.759189 | 0.759189 | 0.759189 | 0.759189 | 1.00 | 1.00 | 0.759189 |
| SPLIT MSE | 0.729840 | 0.729840 | 0.729840 | 0.729840 | 0.729840 | 0.729840 | 1.00 | 1.000000 | 0.729840 |
| SPLIT MNE | 0.698204 | 0.698204 | 0.698204 | 0.698204 | 0.698204 | 0.698204 | 1.00 | 1.00 | 0.698204 |
| SPLIT MN1 | 0.626779 | 0.626779 | 0.626779 | 0.626779 | 0.626779 | 0.626779 | 1.00 | 1.000000 | 0.626779 |
| SPLIT MN2 | 0.625750 | 0.625750 | 0.625750 | 0.625750 | 0.625750 | 0.625750 | 1.00 | 1.000000 | 0.625750 |
| SPLIT MS1 | 0.662300 | 0.662300 | 0.662300 | 0.662300 | 0.662300 | 0.662300 | 1.00 | 1.00 | 0.662300 |
| SPLIT MS2 | 0.661230 | 0.661230 | 0.661230 | 0.661230 | 0.661230 | 0.661230 | 1.00 | 1.000000 | 0.661230 |
| SPLIT TSW | 0.441412 | 0.441412 | 0.441412 | 0.441412 | 0.441412 | 0.441412 | 1.00 | 1.000000 | 0.441412 |
| SPLIT TNW | 0.428825 | 0.428825 | 0.428825 | 0.428825 | 0.428825 | 0.428825 | 1.00 | 1.00 | 0.428825 |
| SPLIT TSE | 0.394443 | 0.394443 | 0.394443 | 0.394443 | 0.394443 | 0.394443 | 1.00 | 1.00 | 0.394443 |
| SPLIT TNE | 0.381856 | 0.381856 | 0.381856 | 0.381856 | 0.381856 | 0.381856 | 1.00 | 1.00 | 0.381856 |
| SPLIT TN1 | 0.353952 | 0.353952 | 0.353952 | 0.353952 | 0.353952 | 0.353952 | 1.00 | 1.00 | 0.353952 |
| SPLIT TN2 | 0.352453 | 0.352453 | 0.352453 | 0.352453 | 0.352453 | 0.352453 | 1.00 | 1.00 | 0.352453 |
| SPLIT TS1 | 0.367495 | 0.367495 | 0.367495 | 0.367495 | 0.367495 | 0.367495 | 1.00 | 1.00 | 0.367495 |
| SPLIT TS2 | 0.366004 | 0.366004 | 0.366004 | 0.366004 | 0.366004 | 0.366004 | 1.00 | 1.00 | 0.366004 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.354086 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.338807 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.392321 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.315660 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.282965 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.282551 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.299996 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.302213 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.791266 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.759189 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.729840 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.698204 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.626779 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.625750 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.662300 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.661230 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.441412 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.428825 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.394443 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.381856 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.353952 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.352453 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.367495 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.366004 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.354086 | 0.354086 | 0.354086 | 0.354086 | 6574.62 | 8608.96 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.338807 | 0.338807 | 0.338807 | 0.338807 | 6322.01 | 8259.70 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.392321 | 0.392321 | 0.392321 | 0.392321 | 7243.39 | 9724.95 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.315660 | 0.315660 | 0.315660 | 0.315660 | 5982.20 | 7730.78 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.282965 | 0.282965 | 0.282965 | 0.282965 | 5389.01 | 6983.61 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.282551 | 0.282551 | 0.282551 | 0.282551 | 5382.77 | 6974.16 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.299996 | 0.299996 | 0.299996 | 0.299996 | 5676.82 | 7372.88 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.302213 | 0.302213 | 0.302213 | 0.302213 | 5710.99 | 7423.55 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.791266 | 0.791266 | 0.791266 | 0.791266 | 14634.66 | 19116.81 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.759189 | 0.759189 | 0.759189 | 0.759189 | 14114.77 | 18383.58 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.729840 | 0.729840 | 0.729840 | 0.729840 | 13730.66 | 17713.16 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.698204 | 0.698204 | 0.698204 | 0.698204 | 13219.30 | 16990.01 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.626779 | 0.626779 | 0.626779 | 0.626779 | 11873.00 | 15357.74 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.625750 | 0.625750 | 0.625750 | 0.625750 | 11857.44 | 15334.22 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.662300 | 0.662300 | 0.662300 | 0.662300 | 12449.29 | 16169.62 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.661230 | 0.661230 | 0.661230 | 0.661230 | 12433.39 | 16145.17 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.441412 | 0.441412 | 0.441412 | 0.441412 | 8112.88 | 10604.64 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.428825 | 0.428825 | 0.428825 | 0.428825 | 7905.19 | 10316.86 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.394443 | 0.394443 | 0.394443 | 0.394443 | 7396.60 | 9531.33 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.381856 | 0.381856 | 0.381856 | 0.381856 | 7188.75 | 9243.57 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.353952 | 0.353952 | 0.353952 | 0.353952 | 6578.83 | 8605.80 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.352453 | 0.352453 | 0.352453 | 0.352453 | 6556.09 | 8571.55 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.367495 | 0.367495 | 0.367495 | 0.367495 | 6802.97 | 8915.40 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.366004 | 0.366004 | 0.366004 | 0.366004 | 6780.39 | 8881.33 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.354086 | 6574.62 | 0.800771 |
| SPLIT GNW COOLING COIL | 0.338807 | 6322.01 | 0.800159 |
| SPLIT OFFICE COOLING COIL | 0.392321 | 7243.39 | 0.800633 |
| SPLIT GNE COOLING COIL | 0.315660 | 5982.20 | 0.798137 |
| SPLIT GN1 COOLING COIL | 0.282965 | 5389.01 | 0.796562 |
| SPLIT GN2 COOLING COIL | 0.282551 | 5382.77 | 0.796465 |
| SPLIT GS1 COOLING COIL | 0.299996 | 5676.82 | 0.798619 |
| SPLIT GS2 COOLING COIL | 0.302213 | 5710.99 | 0.800058 |
| SPLIT MSW COOLING COIL | 0.791266 | 14634.66 | 0.800057 |
| SPLIT MNW COOLING COIL | 0.759189 | 14114.77 | 0.800347 |
| SPLIT MSE COOLING COIL | 0.729840 | 13730.66 | 0.800495 |
| SPLIT MNE COOLING COIL | 0.698204 | 13219.30 | 0.798444 |
| SPLIT MN1 COOLING COIL | 0.626779 | 11873.00 | 0.798282 |
| SPLIT MN2 COOLING COIL | 0.625750 | 11857.44 | 0.798175 |
| SPLIT MS1 COOLING COIL | 0.662300 | 12449.29 | 0.800774 |
| SPLIT MS2 COOLING COIL | 0.661230 | 12433.39 | 0.800664 |
| SPLIT TSW COOLING COIL | 0.441412 | 8112.88 | 0.800132 |
| SPLIT TNW COOLING COIL | 0.428825 | 7905.19 | 0.800141 |
| SPLIT TSE COOLING COIL | 0.394443 | 7396.60 | 0.800551 |
| SPLIT TNE COOLING COIL | 0.381856 | 7188.75 | 0.800280 |
| SPLIT TN1 COOLING COIL | 0.353952 | 6578.83 | 0.800437 |
| SPLIT TN2 COOLING COIL | 0.352453 | 6556.09 | 0.800181 |
| SPLIT TS1 COOLING COIL | 0.367495 | 6802.97 | 0.800764 |
| SPLIT TS2 COOLING COIL | 0.366004 | 6780.39 | 0.800522 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 8608.96 |
| SPLIT GNW HEATING COIL | 8259.70 |
| SPLIT OFFICE HEATING COIL | 9724.95 |
| SPLIT GNE HEATING COIL | 7730.78 |
| SPLIT GN1 HEATING COIL | 6983.61 |
| SPLIT GN2 HEATING COIL | 6974.16 |
| SPLIT GS1 HEATING COIL | 7372.88 |
| SPLIT GS2 HEATING COIL | 7423.55 |
| SPLIT MSW HEATING COIL | 19116.81 |
| SPLIT MNW HEATING COIL | 18383.58 |
| SPLIT MSE HEATING COIL | 17713.16 |
| SPLIT MNE HEATING COIL | 16990.01 |
| SPLIT MN1 HEATING COIL | 15357.74 |
| SPLIT MN2 HEATING COIL | 15334.22 |
| SPLIT MS1 HEATING COIL | 16169.62 |
| SPLIT MS2 HEATING COIL | 16145.17 |
| SPLIT TSW HEATING COIL | 10604.64 |
| SPLIT TNW HEATING COIL | 10316.86 |
| SPLIT TSE HEATING COIL | 9531.33 |
| SPLIT TNE HEATING COIL | 9243.57 |
| SPLIT TN1 HEATING COIL | 8605.80 |
| SPLIT TN2 HEATING COIL | 8571.55 |
| SPLIT TS1 HEATING COIL | 8915.40 |
| SPLIT TS2 HEATING COIL | 8881.33 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 24.20 | 18.90 | 15.70 | 13.60 | 15.50 | 17.10 | 21.20 | 26.90 | 27.60 | 27.90 | 27.40 | 26.20 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Tampa-MacDill AFB FL USA TMY3 WMO#=747880 | 27.85 | -82.52 | -5.00 | 8.00 | 101229 | 1.2032 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 21.85 | 14.30 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 1.025E-003 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 1.025E-003 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 6.000E-002 | 6.799E-004 | 4.088E-004 | 0.803 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 3.619E-002 | 4.101E-004 | 2.929E-004 | 0.484 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.025E-003 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 1.048E-002 | 1.349E-004 | 1.192E-004 | 0.159 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 4173.72229 | 5008.46675 | 0.29507 | 0.35409 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 806.81466 | 968.17759 | 3.47934E-002 | 4.17520E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3998.63055 | 4798.35666 | 0.28234 | 0.33881 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 686.71301 | 824.05561 | 2.96146E-002 | 3.55375E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4451.81282 | 5342.17538 | 0.32693 | 0.39232 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 30.00267 | 1.65290E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 1246.98840 | 1496.38607 | 5.37763E-002 | 6.45315E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 4.60000 | 5.25715E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 3731.19809 | 4477.43771 | 0.26305 | 0.31566 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 688.25119 | 825.90142 | 2.96809E-002 | 3.56171E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 3354.14337 | 4024.97205 | 0.23580 | 0.28296 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 321.74456 | 386.09348 | 1.38754E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 3349.38707 | 4019.26448 | 0.23546 | 0.28255 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 321.79064 | 386.14877 | 1.38774E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3550.34745 | 4260.41694 | 0.25000 | 0.30000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 441.57450 | 529.88939 | 1.90428E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3575.79188 | 4290.95026 | 0.25184 | 0.30221 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 451.75106 | 542.10127 | 1.94817E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 9303.48463 | 11164.18156 | 0.65939 | 0.79127 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 1737.45586 | 2084.94703 | 7.49261E-002 | 8.99113E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 8934.02888 | 10720.83465 | 0.63266 | 0.75919 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 1466.37274 | 1759.64729 | 6.32369E-002 | 7.58842E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 8596.09859 | 10315.31831 | 0.60820 | 0.72984 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 1741.26411 | 2089.51694 | 7.50903E-002 | 9.01084E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 8232.92166 | 9879.50599 | 0.58184 | 0.69820 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 1470.29754 | 1764.35704 | 6.34061E-002 | 7.60874E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 7410.42832 | 8892.51398 | 0.52232 | 0.62678 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 579.04063 | 694.84876 | 2.49713E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 7398.51191 | 8878.21430 | 0.52146 | 0.62575 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 579.14423 | 694.97307 | 2.49757E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 7821.66718 | 9386.00061 | 0.55192 | 0.66230 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 840.25067 | 1008.30080 | 3.62355E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 7809.41543 | 9371.29852 | 0.55102 | 0.66123 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 840.35103 | 1008.42123 | 3.62398E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5183.87329 | 6220.64795 | 0.36784 | 0.44141 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 1684.42527 | 2021.31033 | 7.26382E-002 | 8.71658E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 5038.42337 | 6046.10805 | 0.35735 | 0.42882 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 1539.02163 | 1846.82596 | 6.63689E-002 | 7.96427E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4640.46669 | 5568.56002 | 0.32870 | 0.39444 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 1686.46761 | 2023.76113 | 7.27263E-002 | 8.72715E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 4495.05302 | 5394.06363 | 0.31821 | 0.38186 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 1541.16387 | 1849.39665 | 6.64613E-002 | 7.97536E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 4173.74598 | 5008.49517 | 0.29496 | 0.35395 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 1018.43151 | 1222.11781 | 4.39198E-002 | 5.27037E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 4156.49973 | 4987.79967 | 0.29371 | 0.35245 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 1018.49428 | 1222.19314 | 4.39225E-002 | 5.27070E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4329.81678 | 5195.78014 | 0.30625 | 0.36750 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 1164.34073 | 1397.20888 | 5.02113E-002 | 6.02535E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4312.64054 | 5175.16864 | 0.30500 | 0.36600 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 1164.40014 | 1397.28017 | 5.02138E-002 | 6.02566E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 5025.73 | 0.35409 | 0.35409 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 1471.82 | 4.17520E-002 | 4.17520E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4817.27 | 0.33881 | 0.33881 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 1329.81 | 3.55375E-002 | 3.55375E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5545.58 | 0.39232 | 0.39232 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 2234.74 | 6.45315E-002 | 6.45315E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 4500.35 | 0.31566 | 0.31566 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 1331.62 | 3.56171E-002 | 3.56171E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 4053.04 | 0.28296 | 0.28296 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 4047.38 | 0.28255 | 0.28255 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 4286.07 | 0.30000 | 0.30000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 4316.25 | 0.30221 | 0.30221 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 11187.05 | 0.79127 | 0.79127 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 3090.06 | 8.99113E-002 | 8.99113E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 10748.74 | 0.75919 | 0.75919 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 2769.51 | 7.58842E-002 | 7.58842E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 10347.33 | 0.72984 | 0.72984 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 3094.56 | 9.01084E-002 | 9.01084E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 9915.39 | 0.69820 | 0.69820 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 2774.15 | 7.60874E-002 | 7.60874E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 8939.09 | 0.62678 | 0.62678 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 8924.99 | 0.62575 | 0.62575 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9425.79 | 0.66230 | 0.66230 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9411.19 | 0.66123 | 0.66123 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6221.72 | 0.44141 | 0.44141 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 2509.60 | 8.71658E-002 | 8.71658E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 6049.64 | 0.42882 | 0.42882 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 2337.66 | 7.96427E-002 | 7.96427E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 5579.10 | 0.39444 | 0.39444 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 2512.01 | 8.72715E-002 | 8.72715E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 5406.96 | 0.38186 | 0.38186 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 2340.20 | 7.97536E-002 | 7.97536E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 5025.98 | 0.35395 | 0.35395 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 1722.07 | 5.27037E-002 | 5.27037E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 5005.51 | 0.35245 | 0.35245 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 1722.14 | 5.27070E-002 | 5.27070E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5211.05 | 0.36750 | 0.36750 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 1894.60 | 6.02535E-002 | 6.02535E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5190.69 | 0.36600 | 0.36600 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 1894.67 | 6.02566E-002 | 6.02566E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35409 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33881 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.39232 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31566 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.28296 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.28255 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30000 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30221 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.79127 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.75919 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.72984 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.69820 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.62678 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.62575 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66230 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66123 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.44141 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42882 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.39444 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38186 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35395 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35245 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36750 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36600 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35409 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35409 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35409 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35409 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35409 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.35409 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33881 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33881 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33881 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33881 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33881 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.33881 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.39232 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.39232 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.39232 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.39232 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.39232 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.39232 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31566 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31566 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31566 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31566 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31566 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.31566 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.28296 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.28296 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.28296 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.28296 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.28296 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.28296 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.28255 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.28255 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.28255 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.28255 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.28255 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.28255 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30000 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30000 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30000 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30000 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30000 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30000 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30221 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30221 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30221 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30221 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30221 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30221 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.79127 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.79127 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.79127 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.79127 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.79127 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.79127 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.75919 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.75919 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.75919 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.75919 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.75919 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.75919 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.72984 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.72984 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.72984 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.72984 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.72984 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.72984 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.69820 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.69820 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.69820 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.69820 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.69820 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.69820 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.62678 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.62678 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.62678 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.62678 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.62678 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.62678 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.62575 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.62575 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.62575 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.62575 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.62575 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.62575 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66230 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66230 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66230 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66230 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66230 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66230 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66123 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66123 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66123 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66123 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66123 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66123 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.44141 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.44141 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.44141 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.44141 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.44141 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.44141 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42882 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42882 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42882 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42882 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42882 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.42882 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.39444 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.39444 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.39444 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.39444 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.39444 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.39444 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38186 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38186 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38186 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38186 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38186 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.38186 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35395 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35395 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35395 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35395 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35395 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35395 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35245 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35245 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35245 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35245 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35245 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.35245 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36750 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36750 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36750 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36750 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36750 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36750 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36600 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36600 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36600 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36600 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36600 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36600 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.35409 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.33881 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.39232 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.31566 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.28296 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.28255 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.30000 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.30221 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.79127 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.75919 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.72984 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.69820 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.62678 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.62575 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.66230 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.66123 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.44141 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.42882 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.39444 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.38186 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.35395 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.35245 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.36750 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.36600 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35409 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35409 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35409 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35409 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35409 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6574.61735 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8608.95768 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35409 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35409 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6574.61735 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80077 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 8608.95768 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33881 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33881 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33881 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33881 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33881 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6322.00700 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8259.70006 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33881 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33881 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6322.00700 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80016 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 8259.70006 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.39232 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.39232 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.39232 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.39232 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.39232 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7243.39239 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9724.94748 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.39232 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39232 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7243.39239 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80063 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 9724.94748 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31566 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31566 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31566 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31566 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31566 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5982.20480 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7730.77837 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31566 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31566 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5982.20480 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79814 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 7730.77837 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.28296 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.28296 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28296 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28296 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28296 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5389.01286 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6983.61287 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.28296 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28296 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5389.01286 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79656 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 6983.61287 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.28255 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.28255 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28255 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28255 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28255 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5382.76871 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6974.15551 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.28255 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28255 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5382.76871 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79646 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 6974.15551 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30000 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30000 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30000 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30000 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30000 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5676.82326 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7372.88439 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30000 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30000 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5676.82326 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79862 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 7372.88439 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30221 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30221 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30221 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30221 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30221 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5710.98965 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7423.55031 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30221 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30221 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5710.98965 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80006 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 7423.55031 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.79127 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.79127 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.79127 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.79127 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.79127 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14634.66197 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 19116.81354 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.79127 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.79127 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14634.66197 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80006 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 19116.81354 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.75919 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.75919 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.75919 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.75919 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.75919 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14114.77163 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18383.57893 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.75919 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.75919 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14114.77163 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80035 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 18383.57893 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.72984 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.72984 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.72984 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.72984 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.72984 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13730.65906 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17713.16432 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.72984 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.72984 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13730.65906 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80050 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 17713.16432 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.69820 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.69820 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.69820 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.69820 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.69820 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13219.29678 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16990.00978 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.69820 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69820 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13219.29678 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79844 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 16990.00978 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.62678 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.62678 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.62678 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.62678 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.62678 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11872.99834 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 15357.74221 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.62678 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.62678 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11872.99834 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79828 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 15357.74221 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.62575 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.62575 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.62575 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.62575 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.62575 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11857.43573 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 15334.22469 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.62575 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.62575 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11857.43573 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79818 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 15334.22469 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66230 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66230 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66230 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66230 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66230 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12449.29486 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16169.62498 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66230 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66230 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12449.29486 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80077 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 16169.62498 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66123 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66123 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66123 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66123 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66123 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12433.39367 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 16145.17151 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66123 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66123 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12433.39367 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 16145.17151 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.44141 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.44141 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.44141 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.44141 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.44141 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 8112.87924 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10604.63841 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.44141 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44141 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 8112.87924 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80013 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 10604.63841 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42882 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42882 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42882 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42882 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42882 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7905.18617 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10316.86062 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42882 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42882 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7905.18617 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80014 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 10316.86062 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.39444 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.39444 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.39444 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.39444 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.39444 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7396.60059 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9531.32658 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.39444 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39444 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7396.60059 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80055 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 9531.32658 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38186 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38186 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38186 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38186 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38186 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7188.74634 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9243.57497 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38186 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38186 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7188.74634 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80028 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 9243.57497 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35395 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35395 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35395 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35395 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35395 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6578.83321 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8605.79896 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35395 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35395 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6578.83321 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80044 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 8605.79896 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35245 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35245 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35245 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35245 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35245 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6556.08960 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8571.55199 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35245 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35245 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6556.08960 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80018 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 8571.55199 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36750 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36750 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36750 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36750 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36750 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6802.97252 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8915.39929 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36750 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36750 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6802.97252 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80076 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 8915.39929 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36600 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36600 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36600 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36600 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36600 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6780.38622 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8881.33442 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36600 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36600 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6780.38622 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80052 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 8881.33442 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 6296.7 | 3.20 | 10.91 | 11.35 | 10.73 | 10.72 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 6056.0 | 3.20 | 10.92 | 11.36 | 10.74 | 10.74 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 6935.5 | 3.19 | 10.90 | 11.33 | 10.72 | 10.71 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 5734.4 | 3.21 | 10.95 | 11.39 | 10.78 | 10.78 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 5166.8 | 3.21 | 10.96 | 11.40 | 10.79 | 10.80 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 5160.9 | 3.21 | 10.96 | 11.40 | 10.79 | 10.80 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 5441.3 | 3.21 | 10.95 | 11.39 | 10.77 | 10.78 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 5473.7 | 3.21 | 10.94 | 11.39 | 10.77 | 10.77 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 14013.6 | 3.19 | 10.90 | 11.34 | 10.73 | 10.71 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 13518.8 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 13157.7 | 3.20 | 10.94 | 11.38 | 10.76 | 10.76 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 12671.1 | 3.21 | 10.95 | 11.39 | 10.77 | 10.78 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 11380.9 | 3.21 | 10.95 | 11.39 | 10.77 | 10.78 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 11366.1 | 3.21 | 10.95 | 11.39 | 10.78 | 10.78 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 11929.3 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 11914.3 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 7766.4 | 3.19 | 10.89 | 11.32 | 10.71 | 10.69 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 7568.6 | 3.19 | 10.89 | 11.33 | 10.72 | 10.70 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 7086.9 | 3.20 | 10.93 | 11.37 | 10.75 | 10.75 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 6888.9 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 6301.0 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 6279.4 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 6514.5 | 3.20 | 10.90 | 11.34 | 10.73 | 10.71 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 6493.1 | 3.20 | 10.90 | 11.34 | 10.73 | 10.72 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.200 | 1.017 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.200 | 1.017 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.844 | 0.750 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.854 | 0.757 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.854 | 0.757 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5369_SHGC_0.25 | N/A | 3.053 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.7405685198E-005 | 9.4557074836E-005 | Pass | Pass | 3.0535610870E-002 | 7.4988449455E-002 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.4605824502E-003 | 1.6132622661E-002 | Pass | Pass | 3.3277749879E-002 | 4.2118408039E-002 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 3.1211628631E-002 | 3.4505442440E-002 | Pass | Pass | 0.4703689218 | 1.5989544830 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.6157766761E-003 | 1.5189453984E-002 | Pass | Pass | 2.8678182019E-002 | 4.2149749516E-002 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5493568570E-003 | 9.1725271735E-003 | Pass | Pass | 2.7674204383E-002 | 6.8978014258E-002 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5488983812E-003 | 9.1530992212E-003 | Pass | Pass | 2.7513904591E-002 | 6.8753872143E-002 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.7352033487E-005 | 9.4906532646E-005 | Pass | Pass | 2.3602516797E-002 | 5.4644018077E-002 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.7281207378E-005 | 9.3267440320E-005 | Pass | Pass | 2.0676151795E-002 | 4.3128449681E-002 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 9.1370370083E-004 | 4.7217799251E-003 | Pass | Pass | 3.7133650379E-002 | 7.7836652761E-002 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.4333218425E-003 | 1.9118354943E-002 | Pass | Pass | 3.7655906720E-002 | 3.6800619967E-002 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1451254986E-003 | 5.9724725542E-003 | Pass | Pass | 3.5916178348E-002 | 7.5708743057E-002 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 5.3252844415E-003 | 1.9337628499E-002 | Pass | Pass | 2.9454654703E-002 | 3.6956775367E-002 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5262127454E-003 | 1.0184318808E-002 | Pass | Pass | 2.9473011630E-002 | 6.1648957215E-002 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5284576818E-003 | 1.0225236097E-002 | Pass | Pass | 2.8999349854E-002 | 6.1139648001E-002 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6357994092E-005 | 8.7918171554E-005 | Pass | Pass | 3.0369893026E-002 | 7.6961925141E-002 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6352224342E-005 | 8.7865550982E-005 | Pass | Pass | 3.0416064562E-002 | 7.7151246662E-002 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.7631881380E-002 | 3.8366191047E-002 | Pass | Pass | 4.7348763010E-002 | 5.0744837679E-002 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.2517225155E-002 | 3.7705233263E-002 | Pass | Pass | 5.0679601280E-002 | 7.1293794733E-002 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.8070829057E-002 | 4.1593818600E-002 | Pass | Pass | 4.4418659974E-002 | 4.8919270190E-002 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.2236717941E-002 | 3.8593655413E-002 | Pass | Pass | 4.2267023298E-002 | 6.8930086603E-002 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6502265392E-002 | 3.2222616375E-002 | Pass | Pass | 4.2507441171E-002 | 7.2372563155E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.6516395552E-002 | 3.2210252027E-002 | Pass | Pass | 4.1526773629E-002 | 6.5089226992E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1494878761E-002 | 3.2892626831E-002 | Pass | Pass | 4.4395476709E-002 | 5.1766527712E-002 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1574217506E-002 | 3.2952094934E-002 | Pass | Pass | 4.4510544190E-002 | 4.9051982377E-002 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 3.1250539499E-002 | 1.7124617527E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.1127595493 | 0.2844388431 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 7.6851386843E-003 | 4.1089455532E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1544.38 | -15.0 | 0.00 | 1.44 | 1537.19 | 3067.98 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 4.60 | 0.00 | 4.60 | Wetbulb [C] | 2.50 | 10.00 |
| TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 7.90 | 25.10 | Wetbulb [C] | 3.10 | 270.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 66.00 | 12 | |||
| Feb | 66.00 | 22 | |||
| Mar | 126.00 | 32 | |||
| Apr | 206.00 | 19 | |||
| May | 144.00 | 46 | |||
| Jun | 99.00 | 30 | |||
| Jul | 192.00 | 52 | |||
| Aug | 240.00 | 34 | |||
| Sep | 310.00 | 44 | |||
| Oct | 34.00 | 10 | |||
| Nov | 63.00 | 12 | |||
| Dec | 35.00 | 24 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.273 | 0.283 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.017 | 1.200 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.750 | 0.844 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.757 | 0.854 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.053 | 0.251 | 0.251 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.053 | 0.251 | 0.251 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.5369_SHGC_0.25 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.053 | 0.251 | 0.251 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.5369_SHGC_0.25 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.053 | 0.251 | 0.251 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.5369_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 3.053 | 0.251 | 0.251 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.5369_SHGC_0.25 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 3.053 | 0.251 | 0.251 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.5369_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 3.053 | 0.251 | 0.251 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 3.053 | 0.251 | 0.251 | |||||||||||||||||
| North Total or Average | 112.97 | 3.053 | 0.251 | 0.251 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 3.053 | 0.251 | 0.251 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.73 | 83.73 | 50.03 | |
| Exterior Lighting Total | 3183.33 | 50.03 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6574.62 | 5264.76 | 1309.86 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6322.01 | 5058.61 | 1263.40 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7243.39 | 5799.30 | 1444.09 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5982.20 | 4774.62 | 1207.59 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5389.01 | 4292.68 | 1096.33 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5382.77 | 4287.19 | 1095.58 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5676.82 | 4533.62 | 1143.20 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5710.99 | 4569.12 | 1141.87 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14634.66 | 11708.57 | 2926.09 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14114.77 | 11296.71 | 2818.06 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13730.66 | 10991.33 | 2739.33 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13219.30 | 10554.87 | 2664.43 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11873.00 | 9478.00 | 2395.00 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11857.44 | 9464.31 | 2393.13 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12449.29 | 9969.07 | 2480.22 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12433.39 | 9954.97 | 2478.42 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8112.88 | 6491.37 | 1621.51 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7905.19 | 6325.26 | 1579.92 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7396.60 | 5921.36 | 1475.24 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7188.75 | 5753.01 | 1435.74 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6578.83 | 5265.94 | 1312.89 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6556.09 | 5246.06 | 1310.03 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6802.97 | 5447.58 | 1355.39 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6780.39 | 5427.85 | 1352.54 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 6296.7 | 3.20 | 10.91 | 11.35 | 10.73 | 10.72 | |
| SPLIT GNW COOLING COIL | 6056.0 | 3.20 | 10.92 | 11.36 | 10.74 | 10.74 | |
| SPLIT OFFICE COOLING COIL | 6935.5 | 3.19 | 10.90 | 11.33 | 10.72 | 10.71 | |
| SPLIT GNE COOLING COIL | 5734.4 | 3.21 | 10.95 | 11.39 | 10.78 | 10.78 | |
| SPLIT GN1 COOLING COIL | 5166.8 | 3.21 | 10.96 | 11.40 | 10.79 | 10.80 | |
| SPLIT GN2 COOLING COIL | 5160.9 | 3.21 | 10.96 | 11.40 | 10.79 | 10.80 | |
| SPLIT GS1 COOLING COIL | 5441.3 | 3.21 | 10.95 | 11.39 | 10.77 | 10.78 | |
| SPLIT GS2 COOLING COIL | 5473.7 | 3.21 | 10.94 | 11.39 | 10.77 | 10.77 | |
| SPLIT MSW COOLING COIL | 14013.6 | 3.19 | 10.90 | 11.34 | 10.73 | 10.71 | |
| SPLIT MNW COOLING COIL | 13518.8 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT MSE COOLING COIL | 13157.7 | 3.20 | 10.94 | 11.38 | 10.76 | 10.76 | |
| SPLIT MNE COOLING COIL | 12671.1 | 3.21 | 10.95 | 11.39 | 10.77 | 10.78 | |
| SPLIT MN1 COOLING COIL | 11380.9 | 3.21 | 10.95 | 11.39 | 10.77 | 10.78 | |
| SPLIT MN2 COOLING COIL | 11366.1 | 3.21 | 10.95 | 11.39 | 10.78 | 10.78 | |
| SPLIT MS1 COOLING COIL | 11929.3 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 | |
| SPLIT MS2 COOLING COIL | 11914.3 | 3.20 | 10.93 | 11.37 | 10.76 | 10.76 | |
| SPLIT TSW COOLING COIL | 7766.4 | 3.19 | 10.89 | 11.32 | 10.71 | 10.69 | |
| SPLIT TNW COOLING COIL | 7568.6 | 3.19 | 10.89 | 11.33 | 10.72 | 10.70 | |
| SPLIT TSE COOLING COIL | 7086.9 | 3.20 | 10.93 | 11.37 | 10.75 | 10.75 | |
| SPLIT TNE COOLING COIL | 6888.9 | 3.21 | 10.94 | 11.38 | 10.76 | 10.76 | |
| SPLIT TN1 COOLING COIL | 6301.0 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT TN2 COOLING COIL | 6279.4 | 3.20 | 10.91 | 11.35 | 10.74 | 10.73 | |
| SPLIT TS1 COOLING COIL | 6514.5 | 3.20 | 10.90 | 11.34 | 10.73 | 10.71 | |
| SPLIT TS2 COOLING COIL | 6493.1 | 3.20 | 10.90 | 11.34 | 10.73 | 10.72 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 8608.96 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 8259.70 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 9724.95 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 7730.78 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 6983.61 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 6974.16 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 7372.88 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 7423.55 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 19116.81 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 18383.58 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 17713.16 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 16990.01 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 15357.74 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 15334.22 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 16169.62 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 16145.17 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 10604.64 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 10316.86 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 9531.33 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 9243.57 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 8605.80 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 8571.55 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 8915.40 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 8881.33 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 396.61 | 1120.11 | 1.00 | 1.79 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 379.50 | 1120.11 | 1.00 | 1.81 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 439.44 | 1120.11 | 1.00 | 1.73 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 353.57 | 1120.11 | 1.00 | 1.86 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 316.95 | 1120.11 | 1.00 | 1.94 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 316.49 | 1120.11 | 1.00 | 1.94 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 336.03 | 1120.11 | 1.00 | 1.90 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 338.51 | 1120.11 | 1.00 | 1.89 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.79 | 886.30 | 1120.11 | 1.00 | 1.44 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.76 | 850.37 | 1120.11 | 1.00 | 1.45 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.73 | 817.50 | 1120.11 | 1.00 | 1.46 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.70 | 782.06 | 1120.11 | 1.00 | 1.48 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.63 | 702.06 | 1120.11 | 1.00 | 1.51 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.63 | 700.91 | 1120.11 | 1.00 | 1.51 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.66 | 741.85 | 1120.11 | 1.00 | 1.49 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.66 | 740.65 | 1120.11 | 1.00 | 1.49 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.44 | 494.43 | 1120.11 | 1.00 | 1.66 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 480.33 | 1120.11 | 1.00 | 1.68 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 441.82 | 1120.11 | 1.00 | 1.72 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 427.72 | 1120.11 | 1.00 | 1.74 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 396.46 | 1120.11 | 1.00 | 1.79 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 394.79 | 1120.11 | 1.00 | 1.79 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 411.63 | 1120.11 | 1.00 | 1.76 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 409.96 | 1120.11 | 1.00 | 1.77 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 4173.72 | 5008.47 | 56.75 | 0.295 | 0.354 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00844 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G NW APARTMENT | 3998.63 | 4798.36 | 54.37 | 0.282 | 0.339 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00844 | 30.82 | 0.01653 | 0.026 | 0.00 |
| OFFICE | 4451.81 | 5342.18 | 60.54 | 0.327 | 0.392 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 23.90 | 23.90 | 0.00825 | 30.00 | 0.01653 | 0.038 | 0.00 |
| G NE APARTMENT | 3731.20 | 4477.44 | 50.74 | 0.263 | 0.316 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00850 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G N1 APARTMENT | 3354.14 | 4024.97 | 45.61 | 0.236 | 0.283 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00843 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G N2 APARTMENT | 3349.39 | 4019.26 | 45.54 | 0.235 | 0.283 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00844 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G S1 APARTMENT | 3550.35 | 4260.42 | 48.28 | 0.250 | 0.300 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00844 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G S2 APARTMENT | 3575.79 | 4290.95 | 48.62 | 0.252 | 0.302 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00844 | 30.82 | 0.01653 | 0.026 | 0.00 |
| M SW APARTMENT | 9303.48 | 11164.18 | 126.51 | 0.659 | 0.791 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00850 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M NW APARTMENT | 8934.03 | 10720.83 | 121.48 | 0.633 | 0.759 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00851 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M SE APARTMENT | 8596.10 | 10315.32 | 116.89 | 0.608 | 0.730 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00857 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M NE APARTMENT | 8232.92 | 9879.51 | 111.95 | 0.582 | 0.698 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00858 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M N1 APARTMENT | 7410.43 | 8892.51 | 100.77 | 0.522 | 0.627 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00849 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M N2 APARTMENT | 7398.51 | 8878.21 | 100.60 | 0.521 | 0.626 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00849 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M S1 APARTMENT | 7821.67 | 9386.00 | 106.36 | 0.552 | 0.662 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00848 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M S2 APARTMENT | 7809.42 | 9371.30 | 106.19 | 0.551 | 0.661 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00848 | 30.82 | 0.01653 | 0.052 | 0.00 |
| T SW APARTMENT | 5183.87 | 6220.65 | 70.49 | 0.368 | 0.441 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00853 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T NW APARTMENT | 5038.42 | 6046.11 | 68.51 | 0.357 | 0.429 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00853 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T SE APARTMENT | 4640.47 | 5568.56 | 63.10 | 0.329 | 0.394 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00860 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T NE APARTMENT | 4495.05 | 5394.06 | 61.12 | 0.318 | 0.382 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00861 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T N1 APARTMENT | 4173.75 | 5008.50 | 56.75 | 0.295 | 0.354 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00845 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T N2 APARTMENT | 4156.50 | 4987.80 | 56.52 | 0.294 | 0.352 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00845 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T S1 APARTMENT | 4329.82 | 5195.78 | 58.88 | 0.306 | 0.367 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00845 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T S2 APARTMENT | 4312.64 | 5175.17 | 58.64 | 0.305 | 0.366 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00845 | 30.82 | 0.01653 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 806.81 | 968.18 | 10.97 | 0.035 | 0.042 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | 21.10 | 21.10 | 0.00746 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G NW APARTMENT | 686.71 | 824.06 | 9.34 | 0.030 | 0.036 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00775 | 4.60 | 0.00526 | 0.026 | 0.00 |
| OFFICE | 1246.99 | 1496.39 | 16.96 | 0.054 | 0.065 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00762 | 4.60 | 0.00526 | 0.038 | 0.00 |
| G NE APARTMENT | 688.25 | 825.90 | 9.36 | 0.030 | 0.036 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00775 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G N1 APARTMENT | 321.74 | 386.09 | 4.38 | 0.014 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00791 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G N2 APARTMENT | 321.79 | 386.15 | 4.38 | 0.014 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00791 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G S1 APARTMENT | 441.57 | 529.89 | 6.00 | 0.019 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | 21.10 | 21.10 | 0.00738 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G S2 APARTMENT | 451.75 | 542.10 | 6.14 | 0.019 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00739 | 4.60 | 0.00526 | 0.026 | 0.00 |
| M SW APARTMENT | 1737.46 | 2084.95 | 23.63 | 0.075 | 0.090 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00732 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M NW APARTMENT | 1466.37 | 1759.65 | 19.94 | 0.063 | 0.076 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00755 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M SE APARTMENT | 1741.26 | 2089.52 | 23.68 | 0.075 | 0.090 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00732 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M NE APARTMENT | 1470.30 | 1764.36 | 19.99 | 0.063 | 0.076 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00755 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M N1 APARTMENT | 579.04 | 694.85 | 7.87 | 0.025 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00759 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M N2 APARTMENT | 579.14 | 694.97 | 7.88 | 0.025 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00759 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M S1 APARTMENT | 840.25 | 1008.30 | 11.43 | 0.036 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00715 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M S2 APARTMENT | 840.35 | 1008.42 | 11.43 | 0.036 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00715 | 4.60 | 0.00526 | 0.052 | 0.00 |
| T SW APARTMENT | 1684.43 | 2021.31 | 22.90 | 0.073 | 0.087 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00750 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T NW APARTMENT | 1539.02 | 1846.83 | 20.93 | 0.066 | 0.080 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00763 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T SE APARTMENT | 1686.47 | 2023.76 | 22.93 | 0.073 | 0.087 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00750 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T NE APARTMENT | 1541.16 | 1849.40 | 20.96 | 0.066 | 0.080 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00763 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T N1 APARTMENT | 1018.43 | 1222.12 | 13.85 | 0.044 | 0.053 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00776 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T N2 APARTMENT | 1018.49 | 1222.19 | 13.85 | 0.044 | 0.053 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00776 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T S1 APARTMENT | 1164.34 | 1397.21 | 15.83 | 0.050 | 0.060 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00755 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T S2 APARTMENT | 1164.40 | 1397.28 | 15.83 | 0.050 | 0.060 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00755 | 4.60 | 0.00526 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.35 | 0.35 | 0.04 | 0.04 | 0.3541 | 0.3541 | 0.3541 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.34 | 0.34 | 0.04 | 0.04 | 0.3388 | 0.3388 | 0.3388 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.39 | 0.39 | 0.06 | 0.06 | 0.3923 | 0.3923 | 0.3923 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.32 | 0.32 | 0.04 | 0.04 | 0.3157 | 0.3157 | 0.3157 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.28 | 0.28 | 0.03 | 0.03 | 0.2830 | 0.2830 | 0.2830 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.28 | 0.28 | 0.03 | 0.03 | 0.2826 | 0.2826 | 0.2826 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.30 | 0.30 | 0.03 | 0.03 | 0.3000 | 0.3000 | 0.3000 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.30 | 0.30 | 0.03 | 0.03 | 0.3022 | 0.3022 | 0.3022 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.79 | 0.79 | 0.09 | 0.09 | 0.7913 | 0.7913 | 0.7913 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.76 | 0.76 | 0.08 | 0.08 | 0.7592 | 0.7592 | 0.7592 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.73 | 0.73 | 0.09 | 0.09 | 0.7298 | 0.7298 | 0.7298 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.70 | 0.70 | 0.08 | 0.08 | 0.6982 | 0.6982 | 0.6982 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.63 | 0.63 | 0.05 | 0.05 | 0.6268 | 0.6268 | 0.6268 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.63 | 0.63 | 0.05 | 0.05 | 0.6257 | 0.6257 | 0.6257 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.66 | 0.66 | 0.05 | 0.05 | 0.6623 | 0.6623 | 0.6623 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.66 | 0.66 | 0.05 | 0.05 | 0.6612 | 0.6612 | 0.6612 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.44 | 0.44 | 0.09 | 0.09 | 0.4414 | 0.4414 | 0.4414 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.43 | 0.43 | 0.08 | 0.08 | 0.4288 | 0.4288 | 0.4288 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.39 | 0.39 | 0.09 | 0.09 | 0.3944 | 0.3944 | 0.3944 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.38 | 0.38 | 0.08 | 0.08 | 0.3819 | 0.3819 | 0.3819 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.35 | 0.35 | 0.05 | 0.05 | 0.3540 | 0.3540 | 0.3540 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.35 | 0.35 | 0.05 | 0.05 | 0.3525 | 0.3525 | 0.3525 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.37 | 0.37 | 0.06 | 0.06 | 0.3675 | 0.3675 | 0.3675 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.37 | 0.37 | 0.06 | 0.06 | 0.3660 | 0.3660 | 0.3660 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6574.617 | 5264.762 | 0.354086 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6438.91 | 5477.70 | 0.354086 | 25.45 | 17.34 | 0.00903687 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.3300 | 24.00 | 0.00844413 | 45.4250 | 4173.72 | 0.00 | 6573.50 | 5258.37 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 8608.958 | 8608.958 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | 8608.96 | 8608.96 | 0.354086 | 19.89 | 13.76 | 0.00729422 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.3300 | 21.10 | 0.00745535 | 47.9044 | 806.81 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 6322.007 | 5058.612 | 0.338807 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6195.86 | 5251.66 | 0.338807 | 25.47 | 17.37 | 0.00906382 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.6606 | 24.00 | 0.00844437 | 45.4261 | 3998.63 | 0.00 | 6320.93 | 5051.74 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 8259.700 | 8259.700 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 8259.70 | 8259.70 | 0.338807 | 19.84 | 13.99 | 0.00755473 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.6606 | 21.10 | 0.00774533 | 49.7438 | 686.71 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 7243.392 | 5799.300 | 0.392321 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 7132.52 | 6049.89 | 0.392321 | 25.40 | 17.34 | 0.00905399 | 12.80 | 11.59 | 0.00800000 | 30.00 | 0.01652904 | 24.11 | 9.7130 | 23.90 | 0.00824052 | 44.6110 | 4407.25 | 0.00 | 7242.16 | 5791.89 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 9724.947 | 9724.947 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 9724.95 | 9724.95 | 0.392321 | 19.50 | 13.70 | 0.00739031 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.7130 | 21.10 | 0.00761980 | 48.9477 | 1246.99 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 5982.205 | 4774.620 | 0.315660 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5875.81 | 4912.65 | 0.315660 | 25.50 | 17.46 | 0.00916253 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.2223 | 24.00 | 0.00850243 | 45.7345 | 3731.20 | 0.00 | 5981.19 | 4768.63 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 7730.778 | 7730.778 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 7730.78 | 7730.78 | 0.315660 | 19.74 | 13.94 | 0.00754121 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.2223 | 21.10 | 0.00774584 | 49.7469 | 688.25 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 5389.013 | 4292.683 | 0.282965 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5297.06 | 4422.32 | 0.282965 | 25.56 | 17.49 | 0.00917717 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.1724 | 24.00 | 0.00843458 | 45.3737 | 3354.14 | 0.00 | 5388.10 | 4287.36 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 6983.613 | 6983.613 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 17:50:00 | 6983.61 | 6983.61 | 0.282965 | 19.59 | 14.00 | 0.00766952 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.1724 | 21.10 | 0.00778049 | 49.9663 | 274.28 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 5382.769 | 4287.185 | 0.282551 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5291.15 | 4416.25 | 0.282551 | 25.56 | 17.49 | 0.00917908 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.1858 | 24.00 | 0.00843548 | 45.3785 | 3349.39 | 0.00 | 5381.85 | 4281.81 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 6974.156 | 6974.156 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 6974.16 | 6974.16 | 0.282551 | 19.58 | 14.00 | 0.00766919 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.1858 | 21.10 | 0.00778054 | 49.9666 | 274.33 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5676.823 | 4533.620 | 0.299996 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5574.76 | 4675.59 | 0.299996 | 25.53 | 17.45 | 0.00914221 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.6516 | 24.00 | 0.00844246 | 45.4158 | 3550.35 | 0.00 | 5675.86 | 4527.25 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 7372.884 | 7372.884 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 7372.88 | 7372.88 | 0.299996 | 19.67 | 13.58 | 0.00719651 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.6516 | 21.10 | 0.00728845 | 46.8438 | 387.23 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5710.990 | 4569.123 | 0.302213 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5607.21 | 4708.09 | 0.302213 | 25.52 | 17.44 | 0.00913397 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.5882 | 24.00 | 0.00843905 | 45.3977 | 3575.79 | 0.00 | 5710.02 | 4557.05 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 7423.550 | 7423.550 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 7423.55 | 7423.55 | 0.302213 | 19.68 | 13.60 | 0.00720613 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.5882 | 21.10 | 0.00730565 | 46.9531 | 398.39 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 14634.662 | 11708.569 | 0.791266 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 14324.35 | 12198.01 | 0.791266 | 25.41 | 17.32 | 0.00902687 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.5603 | 24.00 | 0.00850004 | 45.7222 | 18606.97 | 0.00 | 14632.17 | 11695.53 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 19116.814 | 19116.814 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 19116.81 | 19116.81 | 0.791266 | 20.02 | 13.71 | 0.00718431 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.5603 | 21.10 | 0.00731962 | 47.0428 | 3474.91 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 14114.772 | 11296.712 | 0.759189 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 13825.66 | 11724.04 | 0.759189 | 25.42 | 17.35 | 0.00905713 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.8374 | 24.00 | 0.00850864 | 45.7677 | 17868.06 | 0.00 | 14112.37 | 11282.55 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 18383.579 | 18383.579 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18383.58 | 18383.58 | 0.759189 | 19.97 | 13.89 | 0.00739121 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.8374 | 21.10 | 0.00754783 | 48.4910 | 2932.75 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 13730.659 | 10991.331 | 0.729840 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 13471.92 | 11299.50 | 0.729840 | 25.44 | 17.42 | 0.00913501 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.1124 | 24.00 | 0.00856873 | 46.0870 | 17192.20 | 0.00 | 13728.32 | 10978.34 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 17713.164 | 17713.164 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17713.16 | 17713.16 | 0.729840 | 19.93 | 13.66 | 0.00717401 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.1124 | 21.10 | 0.00732078 | 47.0502 | 3482.53 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 13219.297 | 10554.871 | 0.698204 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12982.03 | 10832.24 | 0.698204 | 25.46 | 17.45 | 0.00917318 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.4347 | 24.00 | 0.00858225 | 46.1586 | 16465.84 | 0.00 | 13217.05 | 10539.82 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 16990.010 | 16990.010 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 16990.01 | 16990.01 | 0.698204 | 19.87 | 13.84 | 0.00737838 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.4347 | 21.10 | 0.00754875 | 48.4969 | 2940.60 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 11872.998 | 9477.998 | 0.626779 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11661.11 | 9756.71 | 0.626779 | 25.51 | 17.46 | 0.00915770 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.2819 | 24.00 | 0.00849196 | 45.6787 | 14820.86 | 0.00 | 11870.98 | 9464.29 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 15357.742 | 15357.742 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:30:00 | 15357.74 | 15357.74 | 0.626779 | 19.73 | 13.80 | 0.00739467 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.2819 | 21.10 | 0.00735266 | 47.2512 | 887.97 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 11857.436 | 9464.311 | 0.625750 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11646.38 | 9741.58 | 0.625750 | 25.51 | 17.46 | 0.00915981 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.2955 | 24.00 | 0.00849305 | 45.6845 | 14797.02 | 0.00 | 11855.42 | 9450.50 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 15334.225 | 15334.225 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 15334.22 | 15334.22 | 0.625750 | 19.73 | 13.80 | 0.00739442 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.2955 | 21.10 | 0.00735278 | 47.2520 | 888.17 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 12449.295 | 9969.072 | 0.662300 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12213.57 | 10282.99 | 0.662300 | 25.48 | 17.41 | 0.00911171 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.8377 | 24.00 | 0.00848079 | 45.6195 | 15643.33 | 0.00 | 12447.18 | 9957.62 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 16169.625 | 16169.625 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 16169.62 | 16169.62 | 0.662300 | 19.81 | 13.45 | 0.00699814 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.8377 | 21.10 | 0.00695107 | 44.6996 | 1359.42 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 12433.394 | 9954.974 | 0.661230 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12198.56 | 10267.34 | 0.661230 | 25.48 | 17.41 | 0.00911383 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.8504 | 24.00 | 0.00848199 | 45.6259 | 15618.83 | 0.00 | 12431.28 | 9943.41 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 16145.172 | 16145.172 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:20:00 | 16145.17 | 16145.17 | 0.661230 | 19.80 | 13.45 | 0.00699798 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.8504 | 21.10 | 0.00695118 | 44.7003 | 1359.62 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 8112.879 | 6491.372 | 0.441412 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7933.76 | 6783.30 | 0.441412 | 25.37 | 17.28 | 0.00899670 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 5.8799 | 24.00 | 0.00852604 | 45.8606 | 5183.87 | 0.00 | 8111.50 | 6482.44 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 10604.638 | 10604.638 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10604.64 | 10604.64 | 0.441412 | 20.13 | 13.93 | 0.00736921 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 5.8799 | 21.10 | 0.00750116 | 48.1964 | 1684.43 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 7905.186 | 6325.264 | 0.428825 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7733.91 | 6596.87 | 0.428825 | 25.38 | 17.30 | 0.00901360 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.0525 | 24.00 | 0.00852933 | 45.8780 | 5038.42 | 0.00 | 7903.84 | 6316.09 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 10316.861 | 10316.861 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10316.86 | 10316.86 | 0.428825 | 20.10 | 14.03 | 0.00748842 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.0525 | 21.10 | 0.00763216 | 49.0270 | 1539.02 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 7396.601 | 5921.360 | 0.394443 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7253.76 | 6093.30 | 0.394443 | 25.41 | 17.40 | 0.00912225 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.5801 | 24.00 | 0.00860044 | 46.2556 | 4640.47 | 0.00 | 7395.34 | 5914.97 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 9531.327 | 9531.327 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9531.33 | 9531.33 | 0.394443 | 20.01 | 13.87 | 0.00735396 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.5801 | 21.10 | 0.00750165 | 48.1995 | 1686.47 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 7188.746 | 5753.008 | 0.381856 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7053.88 | 5906.73 | 0.381856 | 25.42 | 17.42 | 0.00914540 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.7969 | 24.00 | 0.00860683 | 46.2894 | 4495.05 | 0.00 | 7187.52 | 5746.06 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 9243.575 | 9243.575 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9243.57 | 9243.57 | 0.381856 | 19.98 | 13.96 | 0.00747112 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.7969 | 21.10 | 0.00763258 | 49.0297 | 1541.16 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 6578.833 | 5265.941 | 0.353952 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6443.97 | 5478.14 | 0.353952 | 25.46 | 17.35 | 0.00904213 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.3328 | 24.00 | 0.00844956 | 45.4536 | 4173.75 | 0.00 | 6577.71 | 5259.38 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 8605.799 | 8605.799 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 8605.80 | 8605.80 | 0.353952 | 19.89 | 14.03 | 0.00757649 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.3328 | 21.10 | 0.00776002 | 49.8372 | 1018.43 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 6556.090 | 5246.062 | 0.352453 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6422.40 | 5456.17 | 0.352453 | 25.46 | 17.35 | 0.00904689 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.3640 | 24.00 | 0.00845199 | 45.4665 | 4156.50 | 0.00 | 6554.97 | 5239.40 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 8571.552 | 8571.552 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 8571.55 | 8571.55 | 0.352453 | 19.88 | 14.03 | 0.00757572 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.3640 | 21.10 | 0.00776004 | 49.8372 | 1018.49 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 6802.973 | 5447.579 | 0.367495 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6659.69 | 5678.75 | 0.367495 | 25.44 | 17.32 | 0.00901992 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.0626 | 24.00 | 0.00844917 | 45.4516 | 4329.82 | 0.00 | 6801.81 | 5441.40 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 8915.399 | 8915.399 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 8915.40 | 8915.40 | 0.367495 | 19.93 | 13.87 | 0.00739004 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.0626 | 21.10 | 0.00755212 | 48.5189 | 1164.34 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 6780.386 | 5427.845 | 0.366004 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6638.27 | 5656.90 | 0.366004 | 25.44 | 17.33 | 0.00902444 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.0913 | 24.00 | 0.00845153 | 45.4641 | 4312.64 | 0.00 | 6779.23 | 5421.58 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 8881.334 | 8881.334 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 8881.33 | 8881.33 | 0.366004 | 19.93 | 13.87 | 0.00738939 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.0913 | 21.10 | 0.00755214 | 48.5190 | 1164.40 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6574.617 | 5264.762 | 0.354086 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6391 | 1004.8586 | 1.2032 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.354086 | 0.42602465 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6438.91 | 5477.70 | 0.9794 | 0.42602465 | 0.354086 | 25.45 | 17.34 | 0.00903687 | 48602.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 396.615 | 6042.29 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.3300 | 24.04 | 0.00844413 | 24.00 | 0.00844413 | 45.4250 | 4173.72 | 0.00 | 6573.50 | 5258.37 | 0.40919990 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.11 | 14.00 | 0.00992456 | 39258.1 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8608.958 | 8608.958 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.354086 | 0.42602465 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:20:00 | Sensible | 8608.96 | 8608.96 | 1.0000 | 0.42602465 | 0.354086 | 19.89 | 13.76 | 0.00729422 | 38498.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8608.96 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.3300 | 21.10 | 0.00745535 | 21.10 | 0.00745535 | 47.9044 | 806.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6322.007 | 5058.612 | 0.338807 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6892 | 1004.8586 | 1.2032 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.338807 | 0.40764155 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6195.86 | 5251.66 | 0.9800 | 0.40764155 | 0.338807 | 25.47 | 17.37 | 0.00906382 | 48692.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 379.501 | 5816.36 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.6606 | 24.04 | 0.00844437 | 24.00 | 0.00844437 | 45.4261 | 3998.63 | 0.00 | 6320.93 | 5051.74 | 0.39154280 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.06 | 13.97 | 0.00991373 | 39178.7 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8259.700 | 8259.700 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.338807 | 0.40764155 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 8259.70 | 8259.70 | 1.0000 | 0.40764155 | 0.338807 | 19.84 | 13.99 | 0.00755473 | 39104.3 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8259.70 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.6606 | 21.10 | 0.00774533 | 21.10 | 0.00774533 | 49.7438 | 686.71 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7243.392 | 5799.300 | 0.392321 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6709 | 1004.8586 | 1.2032 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.392321 | 0.47202706 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | Sensible | 7132.52 | 6049.89 | 0.9847 | 0.47202706 | 0.392321 | 25.40 | 17.34 | 0.00905399 | 48596.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 439.441 | 6693.08 | 30.00 | 0.01652904 | 24.11 | 0.03810604 | 9.7130 | 23.90 | 0.00824983 | 23.90 | 0.00824052 | 44.6110 | 4407.25 | 0.00 | 7242.16 | 5791.89 | 0.45338556 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.18 | 14.03 | 0.00993050 | 39348.9 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9724.947 | 9724.947 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.392321 | 0.47202706 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 9724.95 | 9724.95 | 1.0000 | 0.47202706 | 0.392321 | 19.50 | 13.70 | 0.00739031 | 38342.0 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9724.95 | 4.60 | 0.00525715 | 4.60 | 0.03810604 | 9.7130 | 21.10 | 0.00761980 | 21.10 | 0.00761980 | 48.9477 | 1246.99 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5982.205 | 4774.620 | 0.315660 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8727 | 1004.8586 | 1.2032 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.315660 | 0.37979191 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5875.81 | 4912.65 | 0.9822 | 0.37979191 | 0.315660 | 25.50 | 17.46 | 0.00916253 | 48976.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 353.574 | 5522.23 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.2223 | 24.03 | 0.00850243 | 24.00 | 0.00850243 | 45.7345 | 3731.20 | 0.00 | 5981.19 | 4768.63 | 0.36479300 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.89 | 13.87 | 0.00988141 | 38926.3 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7730.778 | 7730.778 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.315660 | 0.37979191 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 7730.78 | 7730.78 | 1.0000 | 0.37979191 | 0.315660 | 19.74 | 13.94 | 0.00754121 | 38975.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7730.78 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.2223 | 21.10 | 0.00774584 | 21.10 | 0.00774584 | 49.7469 | 688.25 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5389.013 | 4292.683 | 0.282965 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8999 | 1004.8586 | 1.2032 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.282965 | 0.34045382 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5297.06 | 4422.32 | 0.9829 | 0.34045382 | 0.282965 | 25.56 | 17.49 | 0.00917717 | 49069.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 316.951 | 4980.10 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 9.1724 | 24.02 | 0.00843458 | 24.00 | 0.00843458 | 45.3737 | 3354.14 | 0.00 | 5388.10 | 4287.36 | 0.32700847 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.85 | 13.84 | 0.00986489 | 38845.5 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6983.613 | 6983.613 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.282965 | 0.34045382 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 17:50:00 | Sensible | 6983.61 | 6983.61 | 1.0000 | 0.34045382 | 0.282965 | 19.59 | 14.00 | 0.00766952 | 39141.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6983.61 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.1724 | 21.10 | 0.00791314 | 21.10 | 0.00778049 | 49.9663 | 274.28 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5382.769 | 4287.185 | 0.282551 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9035 | 1004.8586 | 1.2032 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.282551 | 0.33995585 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5291.15 | 4416.25 | 0.9830 | 0.33995585 | 0.282551 | 25.56 | 17.49 | 0.00917908 | 49075.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 316.487 | 4974.66 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 9.1858 | 24.02 | 0.00843548 | 24.00 | 0.00843548 | 45.3785 | 3349.39 | 0.00 | 5381.85 | 4281.81 | 0.32653016 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.85 | 13.84 | 0.00986380 | 38840.4 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6974.156 | 6974.156 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.282551 | 0.33995585 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 6974.16 | 6974.16 | 1.0000 | 0.33995585 | 0.282551 | 19.58 | 14.00 | 0.00766919 | 39138.5 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6974.16 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.1858 | 21.10 | 0.00791316 | 21.10 | 0.00778054 | 49.9666 | 274.33 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5676.823 | 4533.620 | 0.299996 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8349 | 1004.8586 | 1.2032 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.299996 | 0.36094522 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5574.76 | 4675.59 | 0.9820 | 0.36094522 | 0.299996 | 25.53 | 17.45 | 0.00914221 | 48949.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 336.028 | 5238.73 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.6516 | 24.03 | 0.00844246 | 24.00 | 0.00844246 | 45.4158 | 3550.35 | 0.00 | 5675.86 | 4527.25 | 0.34669061 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.90 | 13.88 | 0.00988569 | 38950.9 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7372.884 | 7372.884 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.299996 | 0.36094522 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 7372.88 | 7372.88 | 1.0000 | 0.36094522 | 0.299996 | 19.67 | 13.58 | 0.00719651 | 38028.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7372.88 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.6516 | 21.10 | 0.00738019 | 21.10 | 0.00728845 | 46.8438 | 387.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5710.990 | 4569.123 | 0.302213 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8196 | 1004.8586 | 1.2032 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.302213 | 0.36361291 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5607.21 | 4708.09 | 0.9818 | 0.36361291 | 0.302213 | 25.52 | 17.44 | 0.00913397 | 48924.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 338.511 | 5268.70 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.5882 | 24.03 | 0.00843905 | 24.00 | 0.00843905 | 45.3977 | 3575.79 | 0.00 | 5710.02 | 4557.05 | 0.34925294 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.91 | 13.89 | 0.00989032 | 38973.2 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7423.550 | 7423.550 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.302213 | 0.36361291 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 7423.55 | 7423.55 | 1.0000 | 0.36361291 | 0.302213 | 19.68 | 13.60 | 0.00720613 | 38063.7 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7423.55 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.5882 | 21.10 | 0.00738924 | 21.10 | 0.00730565 | 46.9531 | 398.39 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14634.662 | 11708.569 | 0.791266 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6205 | 1004.8586 | 1.2032 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.791266 | 0.95202475 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 14324.35 | 12198.01 | 0.9788 | 0.95202475 | 0.791266 | 25.41 | 17.32 | 0.00902687 | 48530.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 886.303 | 13438.05 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 6.5603 | 24.05 | 0.00850004 | 24.00 | 0.00850004 | 45.7222 | 18606.97 | 0.00 | 14632.17 | 11695.53 | 0.91442697 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.17 | 14.02 | 0.00992552 | 39320.9 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 19116.814 | 19116.814 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.791266 | 0.95202475 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 19116.81 | 19116.81 | 1.0000 | 0.95202475 | 0.791266 | 20.02 | 13.71 | 0.00718431 | 38348.7 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19116.81 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 6.5603 | 21.10 | 0.00731962 | 21.10 | 0.00731962 | 47.0428 | 3474.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14114.772 | 11296.712 | 0.759189 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6768 | 1004.8586 | 1.2032 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.759189 | 0.91343114 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 13825.66 | 11724.04 | 0.9795 | 0.91343114 | 0.759189 | 25.42 | 17.35 | 0.00905713 | 48624.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 850.374 | 12975.29 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 6.8374 | 24.05 | 0.00850864 | 24.00 | 0.00850864 | 45.7677 | 17868.06 | 0.00 | 14112.37 | 11282.55 | 0.87735752 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00992006 | 39237.3 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18383.579 | 18383.579 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.759189 | 0.91343114 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18383.58 | 18383.58 | 1.0000 | 0.91343114 | 0.759189 | 19.97 | 13.89 | 0.00739121 | 38827.5 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18383.58 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 6.8374 | 21.10 | 0.00754783 | 21.10 | 0.00754783 | 48.4910 | 2932.75 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13730.659 | 10991.331 | 0.729840 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8215 | 1004.8586 | 1.2032 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.729840 | 0.87811932 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 13471.92 | 11299.50 | 0.9812 | 0.87811932 | 0.729840 | 25.44 | 17.42 | 0.00913501 | 48838.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 817.500 | 12654.42 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 7.1124 | 24.04 | 0.00856873 | 24.00 | 0.00856873 | 46.0870 | 17192.20 | 0.00 | 13728.32 | 10978.34 | 0.84344024 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.92 | 0.00990632 | 39045.8 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17713.164 | 17713.164 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.729840 | 0.87811932 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17713.16 | 17713.16 | 1.0000 | 0.87811932 | 0.729840 | 19.93 | 13.66 | 0.00717401 | 38229.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17713.16 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.1124 | 21.10 | 0.00732078 | 21.10 | 0.00732078 | 47.0502 | 3482.53 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13219.297 | 10554.871 | 0.698204 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8925 | 1004.8586 | 1.2032 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.698204 | 0.84005534 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12982.03 | 10832.24 | 0.9821 | 0.84005534 | 0.698204 | 25.46 | 17.45 | 0.00917318 | 48956.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 782.063 | 12199.97 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 7.4347 | 24.04 | 0.00858225 | 24.00 | 0.00858225 | 46.1586 | 16465.84 | 0.00 | 13217.05 | 10539.82 | 0.80687951 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.90 | 13.88 | 0.00988375 | 38941.9 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16990.010 | 16990.010 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.698204 | 0.84005534 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 16990.01 | 16990.01 | 1.0000 | 0.84005534 | 0.698204 | 19.87 | 13.84 | 0.00737838 | 38694.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16990.01 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.4347 | 21.10 | 0.00754875 | 21.10 | 0.00754875 | 48.4969 | 2940.60 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11872.998 | 9477.998 | 0.626779 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8637 | 1004.8586 | 1.2032 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.626779 | 0.75411982 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11661.11 | 9756.71 | 0.9822 | 0.75411982 | 0.626779 | 25.51 | 17.46 | 0.00915770 | 48968.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 702.060 | 10959.05 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 8.2819 | 24.03 | 0.00849196 | 24.00 | 0.00849196 | 45.6787 | 14820.86 | 0.00 | 11870.98 | 9464.29 | 0.72433778 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.90 | 13.88 | 0.00988195 | 38933.7 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 15357.742 | 15357.742 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.626779 | 0.75411982 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:30:00 | Sensible | 15357.74 | 15357.74 | 1.0000 | 0.75411982 | 0.626779 | 19.73 | 13.80 | 0.00739467 | 38593.7 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15357.74 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.2819 | 21.10 | 0.00758768 | 21.10 | 0.00735266 | 47.2512 | 887.97 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11857.436 | 9464.311 | 0.625750 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8676 | 1004.8586 | 1.2032 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.625750 | 0.75288153 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11646.38 | 9741.58 | 0.9822 | 0.75288153 | 0.625750 | 25.51 | 17.46 | 0.00915981 | 48974.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 700.907 | 10945.47 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 8.2955 | 24.03 | 0.00849305 | 24.00 | 0.00849305 | 45.6845 | 14797.02 | 0.00 | 11855.42 | 9450.50 | 0.72314840 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.89 | 13.88 | 0.00988076 | 38928.2 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 15334.225 | 15334.225 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.625750 | 0.75288153 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 15334.22 | 15334.22 | 1.0000 | 0.75288153 | 0.625750 | 19.73 | 13.80 | 0.00739442 | 38590.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15334.22 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.2955 | 21.10 | 0.00758775 | 21.10 | 0.00735278 | 47.2520 | 888.17 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12449.295 | 9969.072 | 0.662300 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7782 | 1004.8586 | 1.2032 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.662300 | 0.79685751 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12213.57 | 10282.99 | 0.9811 | 0.79685751 | 0.662300 | 25.48 | 17.41 | 0.00911171 | 48825.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 741.848 | 11471.72 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 7.8377 | 24.04 | 0.00848079 | 24.00 | 0.00848079 | 45.6195 | 15643.33 | 0.00 | 12447.18 | 9957.62 | 0.76538767 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.92 | 0.00990936 | 39059.8 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16169.625 | 16169.625 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.662300 | 0.79685751 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 16169.62 | 16169.62 | 1.0000 | 0.79685751 | 0.662300 | 19.81 | 13.45 | 0.00699814 | 37661.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16169.62 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.8377 | 21.10 | 0.00714620 | 21.10 | 0.00695107 | 44.6996 | 1359.42 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12433.394 | 9954.974 | 0.661230 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7822 | 1004.8586 | 1.2032 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.661230 | 0.79556996 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12198.56 | 10267.34 | 0.9811 | 0.79556996 | 0.661230 | 25.48 | 17.41 | 0.00911383 | 48831.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 740.649 | 11457.91 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 7.8504 | 24.04 | 0.00848199 | 24.00 | 0.00848199 | 45.6259 | 15618.83 | 0.00 | 12431.28 | 9943.41 | 0.76415097 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.92 | 0.00990816 | 39054.3 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 16145.172 | 16145.172 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.661230 | 0.79556996 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:20:00 | Sensible | 16145.17 | 16145.17 | 1.0000 | 0.79556996 | 0.661230 | 19.80 | 13.45 | 0.00699798 | 37659.3 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16145.17 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.8504 | 21.10 | 0.00714628 | 21.10 | 0.00695118 | 44.7003 | 1359.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 8112.879 | 6491.372 | 0.441412 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5644 | 1004.8586 | 1.2032 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.441412 | 0.53109187 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7933.76 | 6783.30 | 0.9779 | 0.53109187 | 0.441412 | 25.37 | 17.28 | 0.00899670 | 48416.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 494.429 | 7439.33 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 5.8799 | 24.06 | 0.00852604 | 24.00 | 0.00852604 | 45.8606 | 5183.87 | 0.00 | 8111.50 | 6482.44 | 0.51011776 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.25 | 14.06 | 0.00993256 | 39421.2 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10604.638 | 10604.638 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.441412 | 0.53109187 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10604.64 | 10604.64 | 1.0000 | 0.53109187 | 0.441412 | 20.13 | 13.93 | 0.00736921 | 38932.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10604.64 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 5.8799 | 21.10 | 0.00750116 | 21.10 | 0.00750116 | 48.1964 | 1684.43 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7905.186 | 6325.264 | 0.428825 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5958 | 1004.8586 | 1.2032 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.428825 | 0.51594762 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7733.91 | 6596.87 | 0.9783 | 0.51594762 | 0.428825 | 25.38 | 17.30 | 0.00901360 | 48470.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 480.330 | 7253.58 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 6.0525 | 24.06 | 0.00852933 | 24.00 | 0.00852933 | 45.8780 | 5038.42 | 0.00 | 7903.84 | 6316.09 | 0.49557159 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 14.04 | 0.00992849 | 39373.4 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10316.861 | 10316.861 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.428825 | 0.51594762 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10316.86 | 10316.86 | 1.0000 | 0.51594762 | 0.428825 | 20.10 | 14.03 | 0.00748842 | 39205.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10316.86 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.0525 | 21.10 | 0.00763216 | 21.10 | 0.00763216 | 49.0270 | 1539.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7396.601 | 5921.360 | 0.394443 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7978 | 1004.8586 | 1.2032 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.394443 | 0.47458028 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7253.76 | 6093.30 | 0.9807 | 0.47458028 | 0.394443 | 25.41 | 17.40 | 0.00912225 | 48778.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 441.818 | 6811.94 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 6.5801 | 24.05 | 0.00860044 | 24.00 | 0.00860044 | 46.2556 | 4640.47 | 0.00 | 7395.34 | 5914.97 | 0.45583795 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.99 | 13.94 | 0.00991136 | 39098.8 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9531.327 | 9531.327 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.394443 | 0.47458028 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9531.33 | 9531.33 | 1.0000 | 0.47458028 | 0.394443 | 20.01 | 13.87 | 0.00735396 | 38775.7 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9531.33 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.5801 | 21.10 | 0.00750165 | 21.10 | 0.00750165 | 48.1995 | 1686.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7188.746 | 5753.008 | 0.381856 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8408 | 1004.8586 | 1.2032 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.381856 | 0.45943651 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7053.88 | 5906.73 | 0.9812 | 0.45943651 | 0.381856 | 25.42 | 17.42 | 0.00914540 | 48850.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 427.720 | 6626.16 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 6.7969 | 24.05 | 0.00860683 | 24.00 | 0.00860683 | 46.2894 | 4495.05 | 0.00 | 7187.52 | 5746.06 | 0.44129224 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.94 | 13.92 | 0.00990396 | 39034.9 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9243.575 | 9243.575 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.381856 | 0.45943651 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9243.57 | 9243.57 | 1.0000 | 0.45943651 | 0.381856 | 19.98 | 13.96 | 0.00747112 | 39036.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9243.57 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.7969 | 21.10 | 0.00763258 | 21.10 | 0.00763258 | 49.0297 | 1541.16 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6578.833 | 5265.941 | 0.353952 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6489 | 1004.8586 | 1.2032 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.353952 | 0.42586344 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6443.97 | 5478.14 | 0.9795 | 0.42586344 | 0.353952 | 25.46 | 17.35 | 0.00904213 | 48620.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 396.465 | 6047.51 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.3328 | 24.05 | 0.00844956 | 24.00 | 0.00844956 | 45.4536 | 4173.75 | 0.00 | 6577.71 | 5259.38 | 0.40904505 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00992102 | 39241.7 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8605.799 | 8605.799 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.353952 | 0.42586344 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 8605.80 | 8605.80 | 1.0000 | 0.42586344 | 0.353952 | 19.89 | 14.03 | 0.00757649 | 39214.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8605.80 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.3328 | 21.10 | 0.00776002 | 21.10 | 0.00776002 | 49.8372 | 1018.43 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6556.090 | 5246.062 | 0.352453 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6577 | 1004.8586 | 1.2032 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.352453 | 0.42406022 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6422.40 | 5456.17 | 0.9796 | 0.42406022 | 0.352453 | 25.46 | 17.35 | 0.00904689 | 48635.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 394.786 | 6027.62 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.3640 | 24.05 | 0.00845199 | 24.00 | 0.00845199 | 45.4665 | 4156.50 | 0.00 | 6554.97 | 5239.40 | 0.40731305 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00991830 | 39229.2 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8571.552 | 8571.552 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.352453 | 0.42406022 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 8571.55 | 8571.55 | 1.0000 | 0.42406022 | 0.352453 | 19.88 | 14.03 | 0.00757572 | 39207.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8571.55 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.3640 | 21.10 | 0.00776004 | 21.10 | 0.00776004 | 49.8372 | 1018.49 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6802.973 | 5447.579 | 0.367495 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6076 | 1004.8586 | 1.2032 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.367495 | 0.44215806 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6659.69 | 5678.75 | 0.9789 | 0.44215806 | 0.367495 | 25.44 | 17.32 | 0.00901992 | 48547.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 411.634 | 6248.06 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.0626 | 24.05 | 0.00844917 | 24.00 | 0.00844917 | 45.4516 | 4329.82 | 0.00 | 6801.81 | 5441.40 | 0.42469616 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.15 | 14.02 | 0.00992873 | 39306.7 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8915.399 | 8915.399 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.367495 | 0.44215806 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 8915.40 | 8915.40 | 1.0000 | 0.44215806 | 0.367495 | 19.93 | 13.87 | 0.00739004 | 38786.5 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8915.40 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.0626 | 21.10 | 0.00755212 | 21.10 | 0.00755212 | 48.5189 | 1164.34 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6780.386 | 5427.845 | 0.366004 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6160 | 1004.8586 | 1.2032 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.366004 | 0.44036446 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6638.27 | 5656.90 | 0.9790 | 0.44036446 | 0.366004 | 25.44 | 17.33 | 0.00902444 | 48561.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 409.965 | 6228.31 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.0913 | 24.05 | 0.00845153 | 24.00 | 0.00845153 | 45.4641 | 4312.64 | 0.00 | 6779.23 | 5421.58 | 0.42297339 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.14 | 14.01 | 0.00992617 | 39294.8 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8881.334 | 8881.334 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.366004 | 0.44036446 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 8881.33 | 8881.33 | 1.0000 | 0.44036446 | 0.366004 | 19.93 | 13.87 | 0.00738939 | 38780.0 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8881.33 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.0913 | 21.10 | 0.00755214 | 21.10 | 0.00755214 | 48.5190 | 1164.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 4343.83 | 3234.33 | 1965.33 |
| G NW APARTMENT | 5959.17 | 5187.00 | 2916.50 |
| OFFICE | 1395.83 | 373.83 | 214.67 |
| G NE APARTMENT | 5937.17 | 5105.33 | 2831.33 |
| G N1 APARTMENT | 5905.17 | 5154.67 | 2978.33 |
| G N2 APARTMENT | 5905.00 | 5150.50 | 2974.83 |
| G S1 APARTMENT | 4422.67 | 3015.17 | 1968.67 |
| G S2 APARTMENT | 4469.17 | 2603.67 | 1602.83 |
| M SW APARTMENT | 4375.83 | 3179.33 | 1998.83 |
| M NW APARTMENT | 6028.00 | 5037.17 | 2897.17 |
| M SE APARTMENT | 4376.50 | 3229.00 | 2028.83 |
| M NE APARTMENT | 6030.83 | 4942.33 | 2795.83 |
| M N1 APARTMENT | 5973.17 | 4963.50 | 2932.50 |
| M N2 APARTMENT | 5974.17 | 4958.00 | 2928.33 |
| M S1 APARTMENT | 4432.17 | 3018.50 | 2049.17 |
| M S2 APARTMENT | 4432.00 | 3019.33 | 2049.00 |
| T SW APARTMENT | 4468.33 | 3916.83 | 2542.67 |
| T NW APARTMENT | 6417.67 | 5593.83 | 3577.00 |
| T SE APARTMENT | 4464.83 | 3971.67 | 2586.83 |
| T NE APARTMENT | 6403.50 | 5557.83 | 3517.00 |
| T N1 APARTMENT | 6269.83 | 5541.67 | 3407.33 |
| T N2 APARTMENT | 6273.83 | 5536.83 | 3406.33 |
| T S1 APARTMENT | 4374.50 | 3743.33 | 2355.17 |
| T S2 APARTMENT | 4374.00 | 3746.17 | 2357.33 |
| T CORRIDOR | 7792.67 | 8609.50 | 7696.67 |
| G CORRIDOR | 6828.50 | 7698.50 | 6076.00 |
| M CORRIDOR | 8475.00 | 8667.33 | 8438.67 |
| Facility | 8659.00 | 8760.00 | 8629.00 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.17 | 0.00 | 0.17 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.17 | 0.00 | 0.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.126 | 0.000 | 0.054 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.134 | 0.000 | 0.061 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.522 | 0.151 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.134 | 0.000 | 0.061 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.081 | 0.000 | 0.061 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.081 | 0.000 | 0.061 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.076 | 0.000 | 0.054 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.076 | 0.000 | 0.054 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.182 | 0.000 | 0.062 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.193 | 0.000 | 0.073 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.182 | 0.000 | 0.062 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.193 | 0.000 | 0.073 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.116 | 0.000 | 0.073 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.116 | 0.000 | 0.073 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.110 | 0.000 | 0.063 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.110 | 0.000 | 0.063 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.240 | 0.000 | 0.071 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.255 | 0.000 | 0.084 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.240 | 0.000 | 0.071 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.255 | 0.000 | 0.085 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.154 | 0.000 | 0.085 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.154 | 0.000 | 0.085 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.145 | 0.000 | 0.071 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.145 | 0.000 | 0.071 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.500 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.17 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 142464.36 | 960967.14 | 308979.68 | 1269946.82 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 2615.00 |
| G NW APARTMENT | 818502.78 | 140970.86 | 959473.64 | 308979.68 | 1268453.32 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 308979.68 | 1510691.65 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 141262.92 | 959765.69 | 308979.68 | 1268745.37 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 0.00 |
| G N1 APARTMENT | 818502.78 | 141753.02 | 960255.80 | 186368.70 | 1146624.50 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 0.00 |
| G N2 APARTMENT | 818502.78 | 141765.39 | 960268.17 | 186368.70 | 1146636.87 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 0.00 |
| G S1 APARTMENT | 818502.78 | 143232.60 | 961735.37 | 186368.70 | 1148104.07 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 143331.97 | 961834.75 | 186368.70 | 1148203.45 | 818502.78 | 0.00 | 7012.67 | 1747.33 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 167099.45 | 1804105.00 | 444026.76 | 2248131.76 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 168350.23 | 1805355.79 | 444026.76 | 2249382.55 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 0.00 |
| M SE APARTMENT | 1637005.55 | 167288.65 | 1804294.21 | 444026.76 | 2248320.96 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 168626.98 | 1805632.53 | 444026.76 | 2249659.29 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 169099.70 | 1806105.25 | 267825.67 | 2073930.92 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 169111.57 | 1806117.12 | 267825.67 | 2073942.79 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 167609.26 | 1804614.81 | 267825.67 | 2072440.48 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 167613.02 | 1804618.58 | 267825.67 | 2072444.24 | 1637005.55 | 0.00 | 6984.33 | 1775.67 | 2615.00 |
| T SW APARTMENT | 818502.78 | 191836.24 | 1010339.01 | 587353.95 | 1597692.96 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 2615.00 |
| T NW APARTMENT | 818502.78 | 195029.82 | 1013532.60 | 587353.95 | 1600886.55 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 0.00 |
| T SE APARTMENT | 818502.78 | 192468.69 | 1010971.47 | 587353.95 | 1598325.42 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 2615.00 |
| T NE APARTMENT | 818502.78 | 195618.63 | 1014121.40 | 587353.95 | 1601475.35 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 0.00 |
| T N1 APARTMENT | 818502.78 | 195592.39 | 1014095.17 | 354276.99 | 1368372.16 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 0.00 |
| T N2 APARTMENT | 818502.78 | 195626.91 | 1014129.69 | 354276.99 | 1368406.68 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 0.00 |
| T S1 APARTMENT | 818502.78 | 192903.69 | 1011406.46 | 354276.99 | 1365683.45 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 192923.92 | 1011426.69 | 354276.99 | 1365703.68 | 818502.78 | 0.00 | 6986.00 | 1774.00 | 2615.00 |
| Total Facility | 39671342.50 | 5236379.11 | 44907721.62 | 11442736.66 | 56350458.28 | 39671342.50 | 0.00 | 8760.00 | 1778.50 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0039 | 0.0299 | 0.0092 | 0.0391 | 0.0260 | 0.00 | 5074.67 | 1070.33 |
| G NW APARTMENT | 0.0260 | 0.0045 | 0.0304 | 0.0098 | 0.0402 | 0.0260 | 0.00 | 7012.67 | 1747.33 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0111 | 0.0492 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0045 | 0.0304 | 0.0098 | 0.0402 | 0.0260 | 0.00 | 7012.67 | 1747.33 |
| G N1 APARTMENT | 0.0260 | 0.0045 | 0.0304 | 0.0059 | 0.0364 | 0.0260 | 0.00 | 7012.67 | 1747.33 |
| G N2 APARTMENT | 0.0260 | 0.0045 | 0.0304 | 0.0059 | 0.0364 | 0.0260 | 0.00 | 7012.67 | 1747.33 |
| G S1 APARTMENT | 0.0260 | 0.0039 | 0.0299 | 0.0056 | 0.0355 | 0.0260 | 0.00 | 5074.67 | 1070.33 |
| G S2 APARTMENT | 0.0260 | 0.0039 | 0.0299 | 0.0056 | 0.0355 | 0.0260 | 0.00 | 5074.67 | 1070.33 |
| M SW APARTMENT | 0.0519 | 0.0046 | 0.0565 | 0.0133 | 0.0697 | 0.0519 | 0.00 | 5054.17 | 1090.83 |
| M NW APARTMENT | 0.0519 | 0.0053 | 0.0572 | 0.0141 | 0.0713 | 0.0519 | 0.00 | 6984.33 | 1775.67 |
| M SE APARTMENT | 0.0519 | 0.0046 | 0.0565 | 0.0133 | 0.0697 | 0.0519 | 0.00 | 5054.17 | 1090.83 |
| M NE APARTMENT | 0.0519 | 0.0053 | 0.0573 | 0.0141 | 0.0713 | 0.0519 | 0.00 | 6984.33 | 1775.67 |
| M N1 APARTMENT | 0.0519 | 0.0054 | 0.0573 | 0.0085 | 0.0658 | 0.0519 | 0.00 | 6984.33 | 1775.67 |
| M N2 APARTMENT | 0.0519 | 0.0054 | 0.0573 | 0.0085 | 0.0658 | 0.0519 | 0.00 | 6984.33 | 1775.67 |
| M S1 APARTMENT | 0.0519 | 0.0046 | 0.0565 | 0.0080 | 0.0645 | 0.0519 | 0.00 | 5054.17 | 1090.83 |
| M S2 APARTMENT | 0.0519 | 0.0046 | 0.0565 | 0.0080 | 0.0645 | 0.0519 | 0.00 | 5054.17 | 1090.83 |
| T SW APARTMENT | 0.0260 | 0.0052 | 0.0311 | 0.0175 | 0.0487 | 0.0260 | 0.00 | 5056.17 | 1088.83 |
| T NW APARTMENT | 0.0260 | 0.0062 | 0.0321 | 0.0186 | 0.0508 | 0.0260 | 0.00 | 6986.00 | 1774.00 |
| T SE APARTMENT | 0.0260 | 0.0052 | 0.0311 | 0.0175 | 0.0487 | 0.0260 | 0.00 | 5056.17 | 1088.83 |
| T NE APARTMENT | 0.0260 | 0.0062 | 0.0322 | 0.0186 | 0.0508 | 0.0260 | 0.00 | 6986.00 | 1774.00 |
| T N1 APARTMENT | 0.0260 | 0.0062 | 0.0322 | 0.0112 | 0.0434 | 0.0260 | 0.00 | 6986.00 | 1774.00 |
| T N2 APARTMENT | 0.0260 | 0.0062 | 0.0322 | 0.0112 | 0.0434 | 0.0260 | 0.00 | 6986.00 | 1774.00 |
| T S1 APARTMENT | 0.0260 | 0.0052 | 0.0312 | 0.0106 | 0.0417 | 0.0260 | 0.00 | 5056.17 | 1088.83 |
| T S2 APARTMENT | 0.0260 | 0.0052 | 0.0312 | 0.0106 | 0.0417 | 0.0260 | 0.00 | 5056.17 | 1088.83 |
| Total Facility | 1.2580 | 0.1546 | 1.4126 | 0.3542 | 1.7668 | 1.2580 | 0.00 | 8760.00 | 1778.50 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 142464.36 | 142464.36 | 818502.78 | 8115.11 | 54.06 | 590.83 | 677.00 |
| SPLIT GNW | 0.00 | 140970.86 | 140970.86 | 818502.78 | 8168.08 | 62.71 | 529.21 | 0.00 |
| SPLIT OFFICE | 1739610.96 | 0.00 | 1739610.96 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 141262.92 | 141262.92 | 818502.78 | 8166.03 | 63.92 | 530.05 | 0.00 |
| SPLIT GN1 | 0.00 | 141753.02 | 141753.02 | 818502.78 | 8141.83 | 66.73 | 551.44 | 0.00 |
| SPLIT GN2 | 0.00 | 141765.39 | 141765.39 | 818502.78 | 8142.44 | 65.74 | 551.82 | 0.00 |
| SPLIT GS1 | 0.00 | 143232.60 | 143232.60 | 818502.78 | 8096.42 | 49.08 | 614.50 | 677.00 |
| SPLIT GS2 | 0.00 | 143331.97 | 143331.97 | 818502.78 | 8095.08 | 49.00 | 615.92 | 677.00 |
| SPLIT MSW | 0.00 | 167099.45 | 167099.45 | 1637005.55 | 8749.83 | 1.33 | 8.83 | 684.83 |
| SPLIT MNW | 0.00 | 168350.23 | 168350.23 | 1637005.55 | 8745.50 | 2.50 | 12.00 | 0.00 |
| SPLIT MSE | 0.00 | 167288.65 | 167288.65 | 1637005.55 | 8749.83 | 1.17 | 9.00 | 684.83 |
| SPLIT MNE | 0.00 | 168626.98 | 168626.98 | 1637005.55 | 8744.92 | 3.08 | 12.00 | 0.00 |
| SPLIT MN1 | 0.00 | 169099.70 | 169099.70 | 1637005.55 | 8744.58 | 3.25 | 12.17 | 0.00 |
| SPLIT MN2 | 0.00 | 169111.57 | 169111.57 | 1637005.55 | 8744.42 | 3.42 | 12.17 | 0.00 |
| SPLIT MS1 | 0.00 | 167609.26 | 167609.26 | 1637005.55 | 8749.83 | 1.17 | 9.00 | 684.83 |
| SPLIT MS2 | 0.00 | 167613.02 | 167613.02 | 1637005.55 | 8749.83 | 1.17 | 9.00 | 684.83 |
| SPLIT TSW | 0.00 | 191836.24 | 191836.24 | 818502.78 | 7608.17 | 42.00 | 1109.83 | 685.17 |
| SPLIT TNW | 0.00 | 195029.82 | 195029.82 | 818502.78 | 7625.67 | 40.57 | 1093.76 | 0.00 |
| SPLIT TSE | 0.00 | 192468.69 | 192468.69 | 818502.78 | 7604.07 | 38.68 | 1117.25 | 685.17 |
| SPLIT TNE | 0.00 | 195618.63 | 195618.63 | 818502.78 | 7616.63 | 43.94 | 1099.43 | 0.00 |
| SPLIT TN1 | 0.00 | 195592.39 | 195592.39 | 818502.78 | 7607.88 | 45.22 | 1106.91 | 0.00 |
| SPLIT TN2 | 0.00 | 195626.91 | 195626.91 | 818502.78 | 7607.99 | 44.84 | 1107.17 | 0.00 |
| SPLIT TS1 | 0.00 | 192903.69 | 192903.69 | 818502.78 | 7590.54 | 42.21 | 1127.25 | 685.17 |
| SPLIT TS2 | 0.00 | 192923.92 | 192923.92 | 818502.78 | 7590.83 | 41.58 | 1127.58 | 685.17 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0039 | 0.0039 | 0.0260 | 5755.11 | 33.22 | 356.67 |
| SPLIT GNW | 0.0000 | 0.0045 | 0.0045 | 0.0260 | 8168.08 | 62.71 | 529.21 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0552 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0045 | 0.0045 | 0.0260 | 8166.03 | 63.92 | 530.05 |
| SPLIT GN1 | 0.0000 | 0.0045 | 0.0045 | 0.0260 | 8141.83 | 66.73 | 551.44 |
| SPLIT GN2 | 0.0000 | 0.0045 | 0.0045 | 0.0260 | 8142.44 | 65.74 | 551.82 |
| SPLIT GS1 | 0.0000 | 0.0039 | 0.0039 | 0.0260 | 5745.83 | 31.33 | 367.83 |
| SPLIT GS2 | 0.0000 | 0.0039 | 0.0039 | 0.0260 | 5744.92 | 31.75 | 368.33 |
| SPLIT MSW | 0.0000 | 0.0046 | 0.0046 | 0.0519 | 6144.00 | 0.17 | 0.83 |
| SPLIT MNW | 0.0000 | 0.0053 | 0.0053 | 0.0519 | 8745.50 | 2.50 | 12.00 |
| SPLIT MSE | 0.0000 | 0.0046 | 0.0046 | 0.0519 | 6144.00 | 0.17 | 0.83 |
| SPLIT MNE | 0.0000 | 0.0053 | 0.0053 | 0.0519 | 8744.92 | 3.08 | 12.00 |
| SPLIT MN1 | 0.0000 | 0.0054 | 0.0054 | 0.0519 | 8744.58 | 3.25 | 12.17 |
| SPLIT MN2 | 0.0000 | 0.0054 | 0.0054 | 0.0519 | 8744.42 | 3.42 | 12.17 |
| SPLIT MS1 | 0.0000 | 0.0046 | 0.0046 | 0.0519 | 6144.00 | 0.17 | 0.83 |
| SPLIT MS2 | 0.0000 | 0.0046 | 0.0046 | 0.0519 | 6144.00 | 0.17 | 0.83 |
| SPLIT TSW | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 5464.67 | 25.58 | 654.75 |
| SPLIT TNW | 0.0000 | 0.0062 | 0.0062 | 0.0260 | 7625.67 | 40.57 | 1093.76 |
| SPLIT TSE | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 5464.86 | 24.81 | 655.33 |
| SPLIT TNE | 0.0000 | 0.0062 | 0.0062 | 0.0260 | 7616.63 | 43.94 | 1099.43 |
| SPLIT TN1 | 0.0000 | 0.0062 | 0.0062 | 0.0260 | 7607.88 | 45.22 | 1106.91 |
| SPLIT TN2 | 0.0000 | 0.0062 | 0.0062 | 0.0260 | 7607.99 | 44.84 | 1107.17 |
| SPLIT TS1 | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 5452.00 | 28.75 | 664.25 |
| SPLIT TS2 | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 5452.50 | 28.25 | 664.25 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 130.32 | 1679.87 | 27-JAN-17:10 | 9041.49 | 09-SEP-17:00 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| ElectricityPurchased:Plant | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| Cogeneration:ElectricityPurchased | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| General:Cogeneration:ElectricityPurchased | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| ElectricityNet:Plant | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| Cogeneration:ElectricityNet | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| General:Cogeneration:ElectricityNet | 1423.52 | 16933.14 | 20-FEB-03:10 | 97430.93 | 09-SEP-17:30 |
| Electricity:HVAC | 438.03 | 1679.87 | 27-JAN-17:10 | 41406.64 | 09-SEP-17:00 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 130.32 | 1679.87 | 27-JAN-17:10 | 9041.49 | 09-SEP-17:00 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 307.71 | 0.00 | 03-JAN-02:40 | 32365.15 | 09-SEP-17:00 |
| General:Cooling:Electricity | 307.71 | 0.00 | 03-JAN-02:40 | 32365.15 | 09-SEP-17:00 |
| ExteriorLights:Electricity | 50.03 | 0.00 | 01-JAN-07:30 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 50.03 | 0.00 | 01-JAN-07:30 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 377.57 | 1950.00 | 01-JAN-00:10 | 37238.61 | 03-JAN-07:30 |
| WaterSystems:Electricity | 377.57 | 1950.00 | 01-JAN-00:10 | 37238.61 | 03-JAN-07:30 |
| Water Heater:WaterSystems:Electricity | 377.57 | 1950.00 | 01-JAN-00:10 | 37238.61 | 03-JAN-07:30 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 26.11 | 0.00 | 01-JAN-00:10 | 50436.00 | 05-FEB-07:20 |
| NaturalGas:HVAC | 26.11 | 0.00 | 01-JAN-00:10 | 50436.00 | 05-FEB-07:20 |
| Heating:NaturalGas | 26.11 | 0.00 | 01-JAN-00:10 | 50436.00 | 05-FEB-07:20 |
| General:Heating:NaturalGas | 26.11 | 0.00 | 01-JAN-00:10 | 50436.00 | 05-FEB-07:20 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 2080.18 | 2959.74 | 31-DEC-10:30 | 183083.48 | 08-OCT-14:00 |
| EnergyTransfer:Building | 835.03 | 2792.76 | 31-DEC-10:30 | 66880.79 | 09-OCT-14:00 |
| EnergyTransfer:Zone:G SW APARTMENT | 27.22 | 0.10 | 11-MAR-09:30 | 2493.13 | 08-OCT-16:10 |
| Heating:EnergyTransfer | 12.81 | 0.00 | 01-JAN-00:10 | 21890.63 | 05-FEB-07:20 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 230.81 | 05-FEB-08:00 |
| General:Heating:EnergyTransfer | 12.81 | 0.00 | 01-JAN-00:10 | 21890.63 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 230.81 | 05-FEB-08:00 |
| Cooling:EnergyTransfer | 822.22 | 2617.45 | 31-DEC-10:30 | 66880.79 | 09-OCT-14:00 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 27.22 | 0.00 | 05-FEB-04:40 | 2493.13 | 08-OCT-16:10 |
| General:Cooling:EnergyTransfer | 822.22 | 2617.45 | 31-DEC-10:30 | 66880.79 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 27.22 | 0.00 | 05-FEB-04:40 | 2493.13 | 08-OCT-16:10 |
| EnergyTransfer:Zone:G NW APARTMENT | 23.02 | 0.06 | 28-JAN-16:00 | 2191.51 | 03-AUG-17:00 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.05 | 0.00 | 01-JAN-00:10 | 564.11 | 05-FEB-08:10 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.05 | 0.00 | 01-JAN-00:10 | 564.11 | 05-FEB-08:10 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 22.96 | 0.00 | 05-JAN-05:00 | 2191.51 | 03-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 22.96 | 0.00 | 05-JAN-05:00 | 2191.51 | 03-AUG-17:00 |
| EnergyTransfer:Zone:OFFICE | 22.35 | 0.00 | 10-MAR-18:40 | 4501.83 | 10-OCT-12:50 |
| Heating:EnergyTransfer:Zone:OFFICE | 3.73 | 0.00 | 01-JAN-00:10 | 655.63 | 24-AUG-17:40 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 3.73 | 0.00 | 01-JAN-00:10 | 655.63 | 24-AUG-17:40 |
| Cooling:EnergyTransfer:Zone:OFFICE | 18.62 | 0.00 | 01-JAN-09:50 | 4501.83 | 10-OCT-12:50 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 18.62 | 0.00 | 01-JAN-09:50 | 4501.83 | 10-OCT-12:50 |
| EnergyTransfer:Zone:G NE APARTMENT | 23.17 | 0.18 | 11-MAR-08:10 | 1961.78 | 03-AUG-17:00 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.05 | 0.00 | 01-JAN-00:10 | 479.14 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.05 | 0.00 | 01-JAN-00:10 | 479.14 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 23.13 | 0.00 | 09-JAN-22:10 | 1961.78 | 03-AUG-17:00 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 23.13 | 0.00 | 09-JAN-22:10 | 1961.78 | 03-AUG-17:00 |
| EnergyTransfer:Zone:G N1 APARTMENT | 20.59 | 0.06 | 08-FEB-16:30 | 1539.52 | 03-AUG-17:10 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 62.60 | 14-MAR-15:00 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 62.60 | 14-MAR-15:00 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 20.59 | 0.00 | 15-JAN-13:30 | 1539.52 | 03-AUG-17:10 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 20.59 | 0.00 | 15-JAN-13:30 | 1539.52 | 03-AUG-17:10 |
| EnergyTransfer:Zone:G N2 APARTMENT | 20.60 | 0.02 | 08-FEB-16:30 | 1536.70 | 03-AUG-17:10 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 62.20 | 14-MAR-15:00 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 62.20 | 14-MAR-15:00 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 20.60 | 0.00 | 15-JAN-13:30 | 1536.70 | 03-AUG-17:10 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 20.60 | 0.00 | 15-JAN-13:30 | 1536.70 | 03-AUG-17:10 |
| EnergyTransfer:Zone:G S1 APARTMENT | 25.18 | 21.30 | 14-MAR-12:00 | 1982.58 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 25.18 | 21.30 | 14-MAR-12:00 | 1982.58 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 25.18 | 21.30 | 14-MAR-12:00 | 1982.58 | 09-OCT-14:00 |
| EnergyTransfer:Zone:G S2 APARTMENT | 27.45 | 34.83 | 14-MAR-11:50 | 2160.00 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 27.45 | 34.83 | 14-MAR-11:50 | 2160.00 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 27.45 | 34.83 | 14-MAR-11:50 | 2160.00 | 09-OCT-14:00 |
| EnergyTransfer:Zone:M SW APARTMENT | 60.28 | 0.80 | 11-MAR-14:40 | 5467.98 | 08-OCT-15:30 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 1172.31 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 1172.31 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 60.24 | 0.00 | 05-FEB-01:10 | 5467.98 | 08-OCT-15:30 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 60.24 | 0.00 | 05-FEB-01:10 | 5467.98 | 08-OCT-15:30 |
| EnergyTransfer:Zone:M NW APARTMENT | 50.91 | 0.03 | 31-DEC-14:30 | 4752.48 | 03-AUG-16:50 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.24 | 0.00 | 01-JAN-00:10 | 1722.48 | 05-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.24 | 0.00 | 01-JAN-00:10 | 1722.48 | 05-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 50.68 | 0.00 | 05-JAN-01:00 | 4752.48 | 03-AUG-16:50 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 50.68 | 0.00 | 05-JAN-01:00 | 4752.48 | 03-AUG-16:50 |
| EnergyTransfer:Zone:M SE APARTMENT | 60.59 | 1.03 | 11-MAR-14:40 | 5310.93 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 1196.96 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 1196.96 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 60.56 | 0.00 | 05-FEB-01:00 | 5310.93 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 60.56 | 0.00 | 05-FEB-01:00 | 5310.93 | 09-OCT-14:00 |
| EnergyTransfer:Zone:M NE APARTMENT | 51.23 | 0.19 | 14-MAR-12:20 | 4472.55 | 19-JUL-13:00 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.22 | 0.00 | 01-JAN-00:10 | 1624.18 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.22 | 0.00 | 01-JAN-00:10 | 1624.18 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 51.01 | 0.00 | 05-JAN-00:50 | 4472.55 | 19-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 51.01 | 0.00 | 05-JAN-00:50 | 4472.55 | 19-JUL-13:00 |
| EnergyTransfer:Zone:M N1 APARTMENT | 44.39 | 0.35 | 31-DEC-13:30 | 3173.91 | 28-JUN-18:00 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 97.31 | 05-FEB-08:10 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 97.31 | 05-FEB-08:10 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 44.39 | 0.00 | 15-JAN-13:40 | 3173.91 | 28-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 44.39 | 0.00 | 15-JAN-13:40 | 3173.91 | 28-JUN-18:00 |
| EnergyTransfer:Zone:M N2 APARTMENT | 44.41 | 0.62 | 08-FEB-13:20 | 3165.03 | 28-JUN-18:00 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 94.05 | 05-FEB-08:10 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 94.05 | 05-FEB-08:10 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 44.41 | 0.00 | 15-JAN-13:40 | 3165.03 | 28-JUN-18:00 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 44.41 | 0.00 | 15-JAN-13:40 | 3165.03 | 28-JUN-18:00 |
| EnergyTransfer:Zone:M S1 APARTMENT | 54.43 | 229.77 | 13-MAR-12:00 | 4291.40 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 54.43 | 229.77 | 13-MAR-12:00 | 4291.40 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 54.43 | 229.77 | 13-MAR-12:00 | 4291.40 | 09-OCT-14:00 |
| EnergyTransfer:Zone:M S2 APARTMENT | 54.45 | 231.62 | 13-MAR-12:00 | 4296.20 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 54.45 | 231.62 | 13-MAR-12:00 | 4296.20 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 54.45 | 231.62 | 13-MAR-12:00 | 4296.20 | 09-OCT-14:00 |
| EnergyTransfer:Zone:T SW APARTMENT | 32.39 | 0.16 | 07-DEC-07:00 | 3736.25 | 08-OCT-15:30 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 1.15 | 0.00 | 01-JAN-00:10 | 2296.66 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 1.15 | 0.00 | 01-JAN-00:10 | 2296.66 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 31.24 | 0.00 | 03-JAN-05:10 | 3736.25 | 08-OCT-15:30 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 31.24 | 0.00 | 03-JAN-05:10 | 3736.25 | 08-OCT-15:30 |
| EnergyTransfer:Zone:T NW APARTMENT | 28.48 | 0.06 | 14-MAR-12:20 | 3360.15 | 03-AUG-16:30 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 1.90 | 0.00 | 01-JAN-00:10 | 2455.05 | 05-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 1.90 | 0.00 | 01-JAN-00:10 | 2455.05 | 05-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 26.58 | 0.00 | 03-JAN-03:50 | 3360.15 | 03-AUG-16:30 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 26.58 | 0.00 | 03-JAN-03:50 | 3360.15 | 03-AUG-16:30 |
| EnergyTransfer:Zone:T SE APARTMENT | 32.46 | 0.22 | 08-MAR-06:40 | 3586.71 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 1.12 | 0.00 | 01-JAN-00:10 | 2310.30 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 1.12 | 0.00 | 01-JAN-00:10 | 2310.30 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 31.34 | 0.00 | 03-JAN-05:10 | 3586.71 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 31.34 | 0.00 | 03-JAN-05:10 | 3586.71 | 09-OCT-14:00 |
| EnergyTransfer:Zone:T NE APARTMENT | 28.54 | 0.10 | 29-OCT-03:50 | 3170.01 | 19-JUL-13:00 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 1.83 | 0.00 | 01-JAN-00:10 | 2412.52 | 05-FEB-07:20 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 1.83 | 0.00 | 01-JAN-00:10 | 2412.52 | 05-FEB-07:20 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 26.71 | 0.00 | 03-JAN-03:50 | 3170.01 | 19-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 26.71 | 0.00 | 03-JAN-03:50 | 3170.01 | 19-JUL-13:00 |
| EnergyTransfer:Zone:T N1 APARTMENT | 23.50 | 0.08 | 21-DEC-23:00 | 2294.45 | 19-JUL-13:00 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.84 | 0.00 | 01-JAN-00:10 | 1520.41 | 05-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.84 | 0.00 | 01-JAN-00:10 | 1520.41 | 05-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 22.66 | 0.00 | 03-JAN-06:00 | 2294.45 | 19-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 22.66 | 0.00 | 03-JAN-06:00 | 2294.45 | 19-JUL-13:00 |
| EnergyTransfer:Zone:T N2 APARTMENT | 23.52 | 0.01 | 11-JAN-10:10 | 2303.97 | 19-JUL-13:00 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.85 | 0.00 | 01-JAN-00:10 | 1518.81 | 05-FEB-08:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.85 | 0.00 | 01-JAN-00:10 | 1518.81 | 05-FEB-08:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 22.67 | 0.00 | 03-JAN-06:00 | 2303.97 | 19-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 22.67 | 0.00 | 03-JAN-06:00 | 2303.97 | 19-JUL-13:00 |
| EnergyTransfer:Zone:T S1 APARTMENT | 27.92 | 0.29 | 21-JAN-00:20 | 2972.06 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.38 | 0.00 | 01-JAN-00:10 | 1375.64 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.38 | 0.00 | 01-JAN-00:10 | 1375.64 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 27.54 | 0.00 | 03-JAN-06:20 | 2972.06 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 27.54 | 0.00 | 03-JAN-06:20 | 2972.06 | 09-OCT-14:00 |
| EnergyTransfer:Zone:T S2 APARTMENT | 27.94 | 0.17 | 21-JAN-09:30 | 2976.22 | 09-OCT-14:00 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.38 | 0.00 | 01-JAN-00:10 | 1376.21 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.38 | 0.00 | 01-JAN-00:10 | 1376.21 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 27.56 | 0.00 | 03-JAN-06:20 | 2976.22 | 09-OCT-14:00 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 27.56 | 0.00 | 03-JAN-06:20 | 2976.22 | 09-OCT-14:00 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 1245.15 | 0.00 | 08-JAN-10:50 | 117702.41 | 08-OCT-14:00 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 15-JUN-10:00 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-02:30 |
| HeatingCoils:EnergyTransfer | 20.89 | 0.00 | 01-JAN-00:10 | 40348.80 | 05-FEB-07:20 |
| CoolingCoils:EnergyTransfer | 1224.26 | 0.00 | 03-JAN-02:40 | 117702.41 | 08-OCT-14:00 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 2.028 | -3.267 | 0.098 | -26.069 | 0.000 | 0.000 | 3.618 | 1.454 | 12.213 | 10.277 | 0.000 | 0.643 | 4.197 | 0.000 | -3.038 | 0.000 | -2.154 | -0.000 |
| G NW APARTMENT | 2.029 | -3.047 | 0.482 | -22.375 | 0.000 | 0.000 | 3.709 | 1.454 | 12.213 | 6.441 | 0.000 | 0.644 | 3.465 | 0.000 | -3.025 | 0.000 | -1.989 | -0.000 |
| OFFICE | 0.000 | 0.000 | 3.734 | -18.616 | 0.000 | 0.000 | 1.975 | 7.396 | 9.469 | 9.661 | 0.000 | 0.327 | 0.000 | 0.000 | -3.914 | 0.000 | -1.966 | -8.064 |
| G NE APARTMENT | 2.029 | -3.048 | 0.470 | -22.530 | 0.000 | 0.000 | 3.711 | 1.454 | 12.213 | 6.440 | 0.000 | 0.644 | 3.520 | 0.000 | -2.908 | 0.000 | -1.995 | -0.000 |
| G N1 APARTMENT | 2.030 | -3.127 | 0.109 | -19.600 | 0.000 | 0.000 | 3.692 | 1.454 | 12.213 | 2.748 | 0.000 | 0.388 | 3.516 | 0.000 | -1.916 | 0.000 | -1.507 | -0.000 |
| G N2 APARTMENT | 2.030 | -3.127 | 0.109 | -19.610 | 0.000 | 0.000 | 3.692 | 1.454 | 12.213 | 2.748 | 0.000 | 0.388 | 3.527 | 0.000 | -1.916 | 0.000 | -1.507 | -0.000 |
| G S1 APARTMENT | 2.028 | -3.371 | 0.003 | -23.835 | 0.000 | 0.000 | 3.594 | 1.454 | 12.213 | 6.632 | 0.000 | 0.388 | 4.400 | 0.000 | -1.863 | 0.000 | -1.643 | -0.000 |
| G S2 APARTMENT | 2.027 | -3.382 | 0.003 | -26.093 | 0.000 | 0.000 | 3.591 | 1.454 | 12.213 | 6.609 | 0.000 | 0.388 | 6.724 | 0.000 | -1.885 | 0.000 | -1.648 | -0.000 |
| M SW APARTMENT | 4.056 | -6.558 | 0.278 | -57.984 | 0.000 | 0.000 | 7.229 | 2.908 | 24.426 | 20.455 | 0.000 | 1.839 | 15.224 | 0.000 | -6.111 | 0.000 | -5.761 | 0.000 |
| M NW APARTMENT | 4.058 | -6.152 | 1.239 | -49.586 | 0.000 | 0.000 | 7.402 | 2.908 | 24.426 | 12.813 | 0.000 | 1.839 | 12.578 | 0.000 | -6.136 | 0.000 | -5.388 | 0.000 |
| M SE APARTMENT | 4.055 | -6.569 | 0.270 | -58.279 | 0.000 | 0.000 | 7.231 | 2.908 | 24.426 | 20.565 | 0.000 | 1.839 | 15.330 | 0.000 | -5.996 | 0.000 | -5.780 | 0.000 |
| M NE APARTMENT | 4.057 | -6.154 | 1.207 | -49.903 | 0.000 | 0.000 | 7.406 | 2.908 | 24.426 | 12.803 | 0.000 | 1.839 | 12.711 | 0.000 | -5.894 | 0.000 | -5.405 | 0.000 |
| M N1 APARTMENT | 4.058 | -6.331 | 0.263 | -42.380 | 0.000 | 0.000 | 7.363 | 2.908 | 24.426 | 5.478 | 0.000 | 1.109 | 10.992 | 0.000 | -3.895 | 0.000 | -3.991 | 0.000 |
| M N2 APARTMENT | 4.058 | -6.331 | 0.263 | -42.400 | 0.000 | 0.000 | 7.364 | 2.908 | 24.426 | 5.477 | 0.000 | 1.109 | 11.013 | 0.000 | -3.895 | 0.000 | -3.992 | 0.000 |
| M S1 APARTMENT | 4.056 | -6.772 | 0.011 | -51.721 | 0.000 | 0.000 | 7.180 | 2.908 | 24.426 | 13.213 | 0.000 | 1.109 | 13.599 | 0.000 | -3.742 | 0.000 | -4.267 | 0.000 |
| M S2 APARTMENT | 4.056 | -6.772 | 0.011 | -51.748 | 0.000 | 0.000 | 7.180 | 2.908 | 24.426 | 13.212 | 0.000 | 1.109 | 13.627 | 0.000 | -3.742 | 0.000 | -4.267 | 0.000 |
| T SW APARTMENT | 2.027 | -3.007 | 2.160 | -31.277 | 0.000 | 0.000 | 3.678 | 1.454 | 12.213 | 10.102 | 0.000 | 1.203 | 7.609 | 0.000 | -2.792 | 0.000 | -3.371 | -0.000 |
| T NW APARTMENT | 2.028 | -2.851 | 3.276 | -27.139 | 0.000 | 0.000 | 3.751 | 1.454 | 12.213 | 6.297 | 0.000 | 1.203 | 5.753 | 0.000 | -2.816 | 0.000 | -3.169 | -0.000 |
| T SE APARTMENT | 2.027 | -3.015 | 2.119 | -31.347 | 0.000 | 0.000 | 3.680 | 1.454 | 12.213 | 10.156 | 0.000 | 1.203 | 7.647 | 0.000 | -2.738 | 0.000 | -3.400 | -0.000 |
| T NE APARTMENT | 2.028 | -2.849 | 3.207 | -27.264 | 0.000 | 0.000 | 3.754 | 1.454 | 12.213 | 6.309 | 0.000 | 1.203 | 5.840 | 0.000 | -2.710 | 0.000 | -3.184 | -0.001 |
| T N1 APARTMENT | 2.028 | -2.897 | 2.025 | -22.973 | 0.000 | 0.000 | 3.740 | 1.454 | 12.213 | 2.691 | 0.000 | 0.725 | 5.045 | 0.000 | -1.781 | 0.000 | -2.270 | -0.000 |
| T N2 APARTMENT | 2.028 | -2.896 | 2.028 | -22.990 | 0.000 | 0.000 | 3.740 | 1.454 | 12.213 | 2.690 | 0.000 | 0.725 | 5.058 | 0.000 | -1.780 | 0.000 | -2.271 | -0.000 |
| T S1 APARTMENT | 2.028 | -3.095 | 1.101 | -27.195 | 0.000 | 0.000 | 3.658 | 1.454 | 12.213 | 6.552 | 0.000 | 0.725 | 6.736 | 0.000 | -1.718 | 0.000 | -2.459 | -0.000 |
| T S2 APARTMENT | 2.027 | -3.095 | 1.104 | -27.218 | 0.000 | 0.000 | 3.658 | 1.454 | 12.213 | 6.551 | 0.000 | 0.725 | 6.757 | 0.000 | -1.716 | 0.000 | -2.460 | -0.000 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.595 | 11.688 | 0.000 | 0.850 | 0.000 | 0.091 | 0.000 | 0.000 | -0.322 | 0.000 | -0.510 | -17.392 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.431 | 11.688 | 3.530 | 2.502 | 0.000 | 2.035 | 0.000 | 0.000 | -1.010 | 0.000 | -10.189 | -13.987 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.846 | 23.376 | 0.000 | 1.692 | 0.000 | 0.161 | 0.000 | 0.000 | -0.704 | 0.000 | -0.882 | -34.490 |
| Total Facility | 62.878 | -97.713 | 25.567 | -800.131 | 0.000 | 0.000 | 137.467 | 99.229 | 391.594 | 211.963 | 0.000 | 25.601 | 184.867 | 0.000 | -79.964 | 0.000 | -87.424 | -73.936 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 08-OCT-16:07 | 0.00 | 233.35 | 0.00 | -2726.59 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 1072.32 | 0.00 | 210.97 | 367.30 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 03-AUG-17:00 | 0.00 | 349.23 | 0.00 | -2540.61 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 1006.07 | 0.00 | 224.89 | 198.04 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 17-OCT-07:02 | 0.00 | 0.00 | 0.00 | -6898.82 | 0.00 | 0.00 | 258.04 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 5775.89 | 0.00 | -150.25 | 0.00 | -156.39 | 0.00 |
| G NE APARTMENT | 03-AUG-17:00 | 0.00 | 349.30 | 0.00 | -2310.98 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 509.74 | 0.00 | 224.89 | 464.67 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 03-AUG-17:05 | 0.00 | 321.65 | 0.00 | -1861.30 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 307.84 | 0.00 | 133.54 | 246.97 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 03-AUG-17:05 | 0.00 | 321.65 | 0.00 | -1858.48 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 307.88 | 0.00 | 133.54 | 244.12 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 09-OCT-14:00 | 0.00 | 243.75 | 0.00 | -2226.51 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1084.91 | 0.00 | 182.31 | 231.96 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 09-OCT-14:00 | 0.00 | 243.70 | 0.00 | -2403.89 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1082.53 | 0.00 | 182.31 | 411.78 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 08-OCT-15:30 | 0.00 | 488.23 | 0.00 | -5956.14 | 0.00 | 0.00 | 334.45 | 121.52 | 941.80 | 3006.26 | 0.00 | 589.48 | 474.41 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 03-AUG-16:50 | 0.00 | 711.40 | 0.00 | -5463.60 | 0.00 | 0.00 | 173.92 | 173.60 | 1177.25 | 2110.11 | 0.00 | 642.15 | 475.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 09-OCT-14:00 | 0.00 | 487.79 | 0.00 | -5799.44 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 2553.06 | 0.00 | 866.23 | 925.21 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 19-JUL-13:00 | 0.00 | 673.63 | 0.00 | -5147.35 | 0.00 | 0.00 | 83.61 | 34.72 | 776.98 | 1376.55 | 0.00 | 1105.10 | 1096.74 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 28-JUN-18:00 | 0.00 | 564.84 | 0.00 | -3738.93 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 714.41 | 0.00 | 274.02 | 483.08 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 28-JUN-18:00 | 0.00 | 564.84 | 0.00 | -3730.06 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 714.50 | 0.00 | 274.02 | 474.12 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 09-OCT-14:00 | 0.00 | 487.66 | 0.00 | -4779.50 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 2166.34 | 0.00 | 522.49 | 635.86 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 09-OCT-14:00 | 0.00 | 487.65 | 0.00 | -4784.30 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 2166.28 | 0.00 | 522.49 | 640.73 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 08-OCT-15:30 | 0.00 | 243.99 | 0.00 | -3980.21 | 0.00 | 0.00 | 167.23 | 60.76 | 470.90 | 1471.16 | 0.00 | 387.67 | 1178.51 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 03-AUG-16:30 | 0.00 | 368.33 | 0.00 | -3728.39 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 1109.13 | 0.00 | 418.12 | 1070.43 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 09-OCT-14:00 | 0.00 | 243.83 | 0.00 | -3831.08 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1246.62 | 0.00 | 569.67 | 1287.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 19-JUL-13:00 | 0.00 | 336.69 | 0.00 | -3507.70 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 662.86 | 0.00 | 727.97 | 1332.53 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 19-JUL-13:00 | 0.00 | 336.69 | 0.00 | -2631.60 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 407.59 | 0.00 | 439.10 | 1000.56 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 19-JUL-13:00 | 0.00 | 336.68 | 0.00 | -2641.11 | 0.00 | 0.00 | 41.81 | 17.36 | 388.49 | 407.45 | 0.00 | 439.10 | 1010.23 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 09-OCT-14:00 | 0.00 | 243.73 | 0.00 | -3216.11 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1065.95 | 0.00 | 343.61 | 1079.26 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 09-OCT-14:00 | 0.00 | 243.72 | 0.00 | -3220.28 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1065.88 | 0.00 | 343.61 | 1083.49 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 09-OCT-14:00 | 0.00 | 7562.52 | 0.00 | -74450.93 | 0.00 | 0.00 | 2146.06 | 2137.20 | 12123.18 | 28417.99 | 0.00 | 11363.91 | 10700.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 05-FEB-08:00 | -751.52 | 0.00 | 982.33 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 22.21 | 0.00 | -342.02 | 0.00 | -545.01 | 0.00 |
| G NW APARTMENT | 05-FEB-08:10 | -736.79 | 0.00 | 1301.26 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 117.67 | 0.00 | -639.01 | 0.00 | -533.71 | 0.00 |
| OFFICE | 30-AUG-16:13 | 0.00 | 0.00 | 771.29 | 0.00 | 0.00 | 0.00 | 0.00 | 116.58 | 294.31 | 555.68 | 0.00 | 72.47 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1810.33 |
| G NE APARTMENT | 05-FEB-07:20 | -751.47 | 0.00 | 1230.91 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 161.13 | 0.00 | -735.95 | 0.00 | -509.39 | 0.00 |
| G N1 APARTMENT | 14-MAR-15:00 | 62.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.26 | 30.38 | 400.26 | 229.64 | 0.00 | 7.88 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -775.01 |
| G N2 APARTMENT | 14-MAR-15:00 | 62.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.23 | 30.38 | 400.26 | 229.43 | 0.00 | 7.80 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -774.30 |
| G S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 05-FEB-07:20 | -1502.83 | 0.00 | 2676.28 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 765.21 | 0.00 | 0.00 | 0.00 | 468.06 | 0.00 | -1444.30 | 0.00 | -1465.24 | 0.00 |
| M NW APARTMENT | 05-FEB-08:00 | -1502.87 | 0.00 | 3225.37 | 0.00 | 0.00 | 0.00 | 331.49 | 112.83 | 765.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1351.61 | 0.00 | -1567.73 | -12.69 |
| M SE APARTMENT | 05-FEB-07:20 | -1502.83 | 0.00 | 2700.92 | 0.00 | 0.00 | 0.00 | 389.98 | 112.83 | 765.21 | 0.00 | 0.00 | 0.00 | 463.91 | 0.00 | -1464.79 | 0.00 | -1465.24 | 0.00 |
| M NE APARTMENT | 05-FEB-07:20 | -1502.81 | 0.00 | 3127.84 | 0.00 | 0.00 | 0.00 | 331.49 | 112.83 | 765.21 | 0.00 | 0.00 | 0.00 | 112.98 | 0.00 | -1482.30 | 0.00 | -1465.24 | 0.00 |
| M N1 APARTMENT | 05-FEB-08:08 | -1473.63 | 0.00 | 1572.36 | 0.00 | 0.00 | 0.00 | 152.09 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 653.75 | 0.00 | -807.62 | 0.00 | -926.02 | 0.00 |
| M N2 APARTMENT | 05-FEB-08:08 | -1473.63 | 0.00 | 1569.00 | 0.00 | 0.00 | 0.00 | 152.09 | 52.08 | 776.98 | 0.00 | 0.00 | 0.00 | 657.15 | 0.00 | -807.66 | 0.00 | -926.02 | 0.00 |
| M S1 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 05-FEB-07:20 | -751.36 | 0.00 | 3048.33 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -680.30 | 0.00 | -970.68 | -1280.00 |
| T NW APARTMENT | 05-FEB-08:00 | -751.39 | 0.00 | 3206.47 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -639.63 | 0.00 | -1038.58 | -1381.65 |
| T SE APARTMENT | 05-FEB-07:20 | -751.36 | 0.00 | 3061.97 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -690.74 | 0.00 | -970.68 | -1283.19 |
| T NE APARTMENT | 05-FEB-07:20 | -751.36 | 0.00 | 3164.17 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -704.53 | 0.00 | -970.68 | -1342.37 |
| T N1 APARTMENT | 05-FEB-08:00 | -751.47 | 0.00 | 2271.90 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -399.57 | 0.00 | -626.44 | -1099.18 |
| T N2 APARTMENT | 05-FEB-08:00 | -751.47 | 0.00 | 2270.30 | 0.00 | 0.00 | 0.00 | 165.74 | 56.42 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -399.58 | 0.00 | -626.44 | -1097.56 |
| T S1 APARTMENT | 05-FEB-07:00 | -751.44 | 0.00 | 2127.09 | 0.00 | 0.00 | 0.00 | 194.99 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -431.91 | 0.00 | -565.02 | -952.32 |
| T S2 APARTMENT | 05-FEB-07:00 | -751.44 | 0.00 | 2127.66 | 0.00 | 0.00 | 0.00 | 194.99 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -431.91 | 0.00 | -565.02 | -952.91 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 05-FEB-07:20 | -23905.16 | 609.88 | 42211.87 | -609.88 | 0.00 | 0.00 | 6732.48 | 3348.00 | 12263.40 | 0.00 | 0.00 | 0.00 | 8693.07 | 0.00 | -19020.75 | 0.00 | -30322.91 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3541 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3541 | 0.0733 | 1.0000 | Not calculated | 0.0260 | 0.0733 | ||
| SPLIT GNW | 0.3388 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3388 | 0.0766 | 1.0000 | Not calculated | 0.0260 | 0.0766 | ||
| SPLIT OFFICE | 0.3923 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3923 | 0.0971 | 1.0000 | Not calculated | 0.0381 | 0.0971 | ||
| SPLIT GNE | 0.3157 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3157 | 0.0822 | 1.0000 | Not calculated | 0.0260 | 0.0822 | ||
| SPLIT GN1 | 0.2830 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2830 | 0.0917 | 1.0000 | Not calculated | 0.0260 | 0.0917 | ||
| SPLIT GN2 | 0.2826 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2826 | 0.0919 | 1.0000 | Not calculated | 0.0260 | 0.0919 | ||
| SPLIT GS1 | 0.3000 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3000 | 0.0865 | 1.0000 | Not calculated | 0.0260 | 0.0865 | ||
| SPLIT GS2 | 0.3022 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3022 | 0.0859 | 1.0000 | Not calculated | 0.0260 | 0.0859 | ||
| SPLIT MSW | 0.7913 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7913 | 0.0656 | 1.0000 | Not calculated | 0.0519 | 0.0656 | ||
| SPLIT MNW | 0.7592 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7592 | 0.0684 | 1.0000 | Not calculated | 0.0519 | 0.0684 | ||
| SPLIT MSE | 0.7298 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7298 | 0.0711 | 1.0000 | Not calculated | 0.0519 | 0.0711 | ||
| SPLIT MNE | 0.6982 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6982 | 0.0743 | 1.0000 | Not calculated | 0.0519 | 0.0743 | ||
| SPLIT MN1 | 0.6268 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6268 | 0.0828 | 1.0000 | Not calculated | 0.0519 | 0.0828 | ||
| SPLIT MN2 | 0.6257 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6257 | 0.0830 | 1.0000 | Not calculated | 0.0519 | 0.0830 | ||
| SPLIT MS1 | 0.6623 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6623 | 0.0784 | 1.0000 | Not calculated | 0.0519 | 0.0784 | ||
| SPLIT MS2 | 0.6612 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6612 | 0.0785 | 1.0000 | Not calculated | 0.0519 | 0.0785 | ||
| SPLIT TSW | 0.4414 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4414 | 0.0588 | 1.0000 | Not calculated | 0.0260 | 0.0588 | ||
| SPLIT TNW | 0.4288 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4288 | 0.0605 | 1.0000 | Not calculated | 0.0260 | 0.0605 | ||
| SPLIT TSE | 0.3944 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3944 | 0.0658 | 1.0000 | Not calculated | 0.0260 | 0.0658 | ||
| SPLIT TNE | 0.3819 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3819 | 0.0680 | 1.0000 | Not calculated | 0.0260 | 0.0680 | ||
| SPLIT TN1 | 0.3540 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3540 | 0.0733 | 1.0000 | Not calculated | 0.0260 | 0.0733 | ||
| SPLIT TN2 | 0.3525 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3525 | 0.0736 | 1.0000 | Not calculated | 0.0260 | 0.0736 | ||
| SPLIT TS1 | 0.3675 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3675 | 0.0706 | 1.0000 | Not calculated | 0.0260 | 0.0706 | ||
| SPLIT TS2 | 0.3660 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3660 | 0.0709 | 1.0000 | Not calculated | 0.0260 | 0.0709 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3541 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3541 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0733 | ||
| SPLIT GNW | 0.3388 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3388 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0766 | ||
| SPLIT OFFICE | 0.3923 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3923 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0971 | ||
| SPLIT GNE | 0.3157 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3157 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0822 | ||
| SPLIT GN1 | 0.2830 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2830 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0917 | ||
| SPLIT GN2 | 0.2826 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2826 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0919 | ||
| SPLIT GS1 | 0.3000 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3000 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0865 | ||
| SPLIT GS2 | 0.3022 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3022 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0859 | ||
| SPLIT MSW | 0.7913 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7913 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0656 | ||
| SPLIT MNW | 0.7592 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7592 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0684 | ||
| SPLIT MSE | 0.7298 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7298 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0711 | ||
| SPLIT MNE | 0.6982 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6982 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0743 | ||
| SPLIT MN1 | 0.6268 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6268 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0828 | ||
| SPLIT MN2 | 0.6257 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6257 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0830 | ||
| SPLIT MS1 | 0.6623 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6623 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0784 | ||
| SPLIT MS2 | 0.6612 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6612 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0785 | ||
| SPLIT TSW | 0.4414 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4414 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0588 | ||
| SPLIT TNW | 0.4288 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4288 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0605 | ||
| SPLIT TSE | 0.3944 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3944 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0658 | ||
| SPLIT TNE | 0.3819 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3819 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0680 | ||
| SPLIT TN1 | 0.3540 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3540 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0733 | ||
| SPLIT TN2 | 0.3525 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3525 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0736 | ||
| SPLIT TS1 | 0.3675 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3675 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0706 | ||
| SPLIT TS2 | 0.3660 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3660 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0709 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3541 | 0.3541 | 0.3541 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3388 | 0.3388 | 0.3388 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3923 | 0.3923 | 0.3923 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3157 | 0.3157 | 0.3157 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2830 | 0.2830 | 0.2830 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2826 | 0.2826 | 0.2826 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3000 | 0.3000 | 0.3000 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3022 | 0.3022 | 0.3022 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7913 | 0.7913 | 0.7913 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7592 | 0.7592 | 0.7592 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7298 | 0.7298 | 0.7298 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6982 | 0.6982 | 0.6982 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6268 | 0.6268 | 0.6268 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6257 | 0.6257 | 0.6257 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6623 | 0.6623 | 0.6623 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6612 | 0.6612 | 0.6612 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4414 | 0.4414 | 0.4414 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4288 | 0.4288 | 0.4288 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3944 | 0.3944 | 0.3944 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3819 | 0.3819 | 0.3819 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3540 | 0.3540 | 0.3540 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3525 | 0.3525 | 0.3525 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3675 | 0.3675 | 0.3675 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3660 | 0.3660 | 0.3660 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3541 | 0.3541 | 0.3541 | 0.3541 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3388 | 0.3388 | 0.3388 | 0.3388 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3923 | 0.3923 | 0.3923 | 0.3923 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3157 | 0.3157 | 0.3157 | 0.3157 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2830 | 0.2830 | 0.2830 | 0.2830 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2826 | 0.2826 | 0.2826 | 0.2826 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3000 | 0.3000 | 0.3000 | 0.3000 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3022 | 0.3022 | 0.3022 | 0.3022 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.7913 | 0.7913 | 0.7913 | 0.7913 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.7592 | 0.7592 | 0.7592 | 0.7592 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7298 | 0.7298 | 0.7298 | 0.7298 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6982 | 0.6982 | 0.6982 | 0.6982 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6268 | 0.6268 | 0.6268 | 0.6268 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6257 | 0.6257 | 0.6257 | 0.6257 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6623 | 0.6623 | 0.6623 | 0.6623 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6612 | 0.6612 | 0.6612 | 0.6612 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4414 | 0.4414 | 0.4414 | 0.4414 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4288 | 0.4288 | 0.4288 | 0.4288 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3944 | 0.3944 | 0.3944 | 0.3944 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3819 | 0.3819 | 0.3819 | 0.3819 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3540 | 0.3540 | 0.3540 | 0.3540 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3525 | 0.3525 | 0.3525 | 0.3525 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3675 | 0.3675 | 0.3675 | 0.3675 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3660 | 0.3660 | 0.3660 | 0.3660 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3541 | 0.3541 | 0.3541 | No | 0.0260 | 0.6216 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3388 | 0.3388 | 0.3388 | No | 0.0260 | 0.7303 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3923 | 0.3923 | 0.3923 | No | 0.0381 | 0.5905 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3157 | 0.3157 | 0.3157 | No | 0.0260 | 0.7287 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2830 | 0.2830 | 0.2830 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2826 | 0.2826 | 0.2826 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3000 | 0.3000 | 0.3000 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3022 | 0.3022 | 0.3022 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7913 | 0.7913 | 0.7913 | No | 0.0519 | 0.5773 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7592 | 0.7592 | 0.7592 | No | 0.0519 | 0.6841 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7298 | 0.7298 | 0.7298 | No | 0.0519 | 0.5761 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6982 | 0.6982 | 0.6982 | No | 0.0519 | 0.6822 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6268 | 0.6268 | 0.6268 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6257 | 0.6257 | 0.6257 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6623 | 0.6623 | 0.6623 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6612 | 0.6612 | 0.6612 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4414 | 0.4414 | 0.4414 | No | 0.0260 | 0.2978 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4288 | 0.4288 | 0.4288 | No | 0.0260 | 0.3259 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3944 | 0.3944 | 0.3944 | No | 0.0260 | 0.2974 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3819 | 0.3819 | 0.3819 | No | 0.0260 | 0.3254 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3540 | 0.3540 | 0.3540 | No | 0.0260 | 0.4925 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3525 | 0.3525 | 0.3525 | No | 0.0260 | 0.4924 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3675 | 0.3675 | 0.3675 | No | 0.0260 | 0.4308 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3660 | 0.3660 | 0.3660 | No | 0.0260 | 0.4307 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3541 | 0.3541 | 0.3541 | 0.3541 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3388 | 0.3388 | 0.3388 | 0.3388 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3923 | 0.3923 | 0.3923 | 0.3923 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3157 | 0.3157 | 0.3157 | 0.3157 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2830 | 0.2830 | 0.2830 | 0.2830 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2826 | 0.2826 | 0.2826 | 0.2826 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3000 | 0.3000 | 0.3000 | 0.3000 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3022 | 0.3022 | 0.3022 | 0.3022 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.7913 | 0.7913 | 0.7913 | 0.7913 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.7592 | 0.7592 | 0.7592 | 0.7592 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7298 | 0.7298 | 0.7298 | 0.7298 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6982 | 0.6982 | 0.6982 | 0.6982 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6268 | 0.6268 | 0.6268 | 0.6268 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6257 | 0.6257 | 0.6257 | 0.6257 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6623 | 0.6623 | 0.6623 | 0.6623 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6612 | 0.6612 | 0.6612 | 0.6612 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4414 | 0.4414 | 0.4414 | 0.4414 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4288 | 0.4288 | 0.4288 | 0.4288 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3944 | 0.3944 | 0.3944 | 0.3944 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3819 | 0.3819 | 0.3819 | 0.3819 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3540 | 0.3540 | 0.3540 | 0.3540 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3525 | 0.3525 | 0.3525 | 0.3525 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3675 | 0.3675 | 0.3675 | 0.3675 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3660 | 0.3660 | 0.3660 | 0.3660 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Tampa-MacDill AFB FL USA TMY3 WMO#=747880 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.17 |
| Number of hours not met | 0.17 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 26.11 | 50436.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 307.71 | 32365.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 50.03 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 130.32 | 9041.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 377.57 | 37238.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1423.52 |
| Natural Gas | 0.00 | 26.11 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1449.63 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 98.16 |
| Fans (All) | 41.58 |
| Service Water Heating | 120.45 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 454.13 |
| Subtotal | 454.13 |
| Natural Gas [MJ/m2] | |
| Space Heating | 8.33 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 8.33 |
| Subtotal | 8.33 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 6.85 |
| Space Heating | 1.80 |
| Space Cooling | 21.23 |
| Fans (All) | 8.99 |
| Service Water Heating | 26.05 |
| Receptacle Equipment | 31.64 |
| Miscellaneous | 3.45 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 4767.17 | 3176.33 | 816.50 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 3942.33 | 4333.83 | 483.83 | 0.00 | 0.00 |
| G CORRIDOR | 4309.67 | 4101.33 | 349.00 | 0.00 | 0.00 |
| M CORRIDOR | 2899.17 | 5860.83 | 0.00 | 0.00 | 0.00 |
| Min | 2899.17 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 5860.83 | 816.50 | 0.00 | 0.00 |
| Average | 8051.79 | 647.12 | 61.09 | 0.00 | 0.00 |
| Sum | 217398.33 | 17472.33 | 1649.33 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6985.33 | 14.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 10599.00 | 11184.00 | 1212.00 | 0.00 | 0.00 |
| G CORRIDOR | 11200.67 | 10687.00 | 1107.33 | 0.00 | 0.00 |
| M CORRIDOR | 7518.33 | 15476.67 | 0.00 | 0.00 | 0.00 |
| Min | 6985.33 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 11830.00 | 15476.67 | 1212.00 | 0.00 | 0.00 |
| Average | 10868.64 | 1383.79 | 85.90 | 0.00 | 0.00 |
| Sum | 293453.33 | 37362.33 | 2319.33 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 5745.33 | 3014.67 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 5396.17 | 3363.83 | 0.00 | 0.00 | 0.00 |
| OFFICE | 3900.50 | 4712.00 | 147.50 | 0.00 | 0.00 |
| G NE APARTMENT | 5480.50 | 3279.50 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 5231.33 | 3528.67 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 5234.33 | 3525.67 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 5696.67 | 3063.33 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 6150.83 | 2609.17 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 5754.83 | 3005.17 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 5455.67 | 3304.33 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 5807.50 | 2952.50 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 5536.83 | 3223.17 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 5301.67 | 3458.33 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 5306.00 | 3454.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 5664.00 | 3096.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 5666.50 | 3093.50 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 5632.83 | 3127.17 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 5446.00 | 3314.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 5672.67 | 3087.33 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 5487.17 | 3272.83 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 5399.50 | 3360.50 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 5402.17 | 3357.83 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 5649.00 | 3111.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 5653.00 | 3107.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 1378.67 | 5858.00 | 1523.33 | 0.00 | 0.00 |
| G CORRIDOR | 2584.83 | 5367.83 | 807.33 | 0.00 | 0.00 |
| M CORRIDOR | 381.00 | 7609.17 | 769.83 | 0.00 | 0.00 |
| Min | 381.00 | 2609.17 | 0.00 | 0.00 | 0.00 |
| Max | 6150.83 | 7609.17 | 1523.33 | 0.00 | 0.00 |
| Average | 5037.61 | 3602.09 | 120.30 | 0.00 | 0.00 |
| Sum | 136015.50 | 97256.50 | 3248.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 7296.33 | 4533.67 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 6119.67 | 4465.33 | 0.00 | 0.00 | 0.00 |
| OFFICE | 5976.67 | 1023.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 5941.00 | 4644.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 5905.67 | 4679.33 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 5901.17 | 4683.83 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 7206.33 | 4623.67 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 7843.17 | 3986.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 7349.33 | 4480.67 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 6274.00 | 4311.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 7220.33 | 4609.67 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 6091.00 | 4494.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 6091.50 | 4493.50 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 6088.33 | 4496.67 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 7217.17 | 4612.83 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 7218.00 | 4612.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 6990.67 | 4839.33 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 6031.17 | 4553.83 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 6854.17 | 4975.83 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 5809.67 | 4775.33 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 5941.00 | 4644.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 5932.83 | 4652.17 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 6995.33 | 4834.67 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 6991.50 | 4838.50 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 3575.00 | 15566.17 | 3853.83 | 0.00 | 0.00 |
| G CORRIDOR | 6336.33 | 13669.83 | 2988.83 | 0.00 | 0.00 |
| M CORRIDOR | 996.67 | 20202.17 | 1796.17 | 0.00 | 0.00 |
| Min | 996.67 | 1023.33 | 0.00 | 0.00 | 0.00 |
| Max | 7843.17 | 20202.17 | 3853.83 | 0.00 | 0.00 |
| Average | 6229.41 | 5788.97 | 319.96 | 0.00 | 0.00 |
| Sum | 168194.00 | 156302.17 | 8638.83 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:16:53
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2A
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_FL_TAMPA
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.131192E+10 | 1968.31 | 01-JAN-16:10 | 24.83 | 18.70 | 0.112812E+09 | 70.36 | 15-JAN-23:00 | 15.80 | 13.09 |
| February | 0.113484E+10 | 1722.04 | 27-FEB-16:10 | 25.32 | 20.49 | 0.101408E+09 | 70.36 | 07-FEB-19:10 | 25.32 | 20.49 |
| March | 0.107307E+10 | 1445.03 | 06-MAR-16:10 | 25.92 | 21.45 | 0.109885E+09 | 70.35 | 19-MAR-05:10 | 18.37 | 15.61 |
| April | 0.148336E+10 | 1726.29 | 29-APR-16:07 | 29.80 | 23.87 | 0.122298E+09 | 70.37 | 10-APR-20:00 | 29.80 | 23.87 |
| May | 0.253461E+10 | 1778.61 | 10-MAY-16:30 | 32.50 | 22.86 | 0.125733E+09 | 70.30 | 17-MAY-00:49 | 23.40 | 20.30 |
| June | 0.268228E+10 | 1885.28 | 10-JUN-17:05 | 32.52 | 22.13 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.307267E+10 | 1977.41 | 22-JUL-16:40 | 35.37 | 26.88 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 35.37 | 26.88 |
| August | 0.344266E+10 | 2273.83 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.325831E+10 | 2411.72 | 10-SEP-16:04 | 34.10 | 26.94 | 0.123963E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.330109E+10 | 2493.26 | 08-OCT-16:07 | 30.67 | 25.13 | 0.127364E+09 | 70.36 | 28-OCT-00:40 | 12.67 | 7.02 |
| November | 0.219409E+10 | 2113.96 | 06-NOV-16:10 | 28.02 | 20.18 | 0.122996E+09 | 70.37 | 17-NOV-02:49 | 14.38 | 11.20 |
| December | 0.172803E+10 | 2066.69 | 10-DEC-16:10 | 26.67 | 20.14 | 0.119355E+09 | 70.37 | 23-DEC-19:19 | 18.33 | 14.05 |
| Annual Sum or Average | 0.272169E+11 | 0.143947E+10 | ||||||||
| Minimum of Months | 0.107307E+10 | 1445.03 | 24.83 | 18.70 | 0.101408E+09 | 70.28 | 12.67 | 7.02 | ||
| Maximum of Months | 0.344266E+10 | 2493.26 | 36.07 | 26.94 | 0.129276E+09 | 70.37 | 36.07 | 26.88 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.720436E+09 | 1049.46 | 01-JAN-17:03 | 23.33 | 19.19 | 97044605.57 | 70.32 | 18-JAN-00:40 | 19.33 | 17.99 |
| February | 0.615410E+09 | 1053.65 | 27-FEB-17:05 | 24.12 | 20.12 | 93628993.84 | 70.33 | 26-FEB-01:19 | 24.12 | 20.12 |
| March | 0.738398E+09 | 1003.26 | 29-MAR-16:14 | 26.43 | 21.14 | 0.109401E+09 | 70.34 | 29-MAR-01:39 | 26.43 | 21.14 |
| April | 0.125095E+10 | 1535.96 | 29-APR-16:20 | 29.60 | 23.75 | 0.121986E+09 | 70.35 | 19-APR-03:00 | 29.60 | 23.75 |
| May | 0.252083E+10 | 1764.56 | 29-MAY-17:10 | 30.40 | 23.75 | 0.128774E+09 | 70.30 | 17-MAY-00:49 | 30.40 | 23.75 |
| June | 0.275677E+10 | 1939.61 | 28-JUN-17:30 | 32.50 | 24.86 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.50 | 24.86 |
| July | 0.310297E+10 | 2011.00 | 07-JUL-16:30 | 33.60 | 24.99 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 23.30 | 22.94 |
| August | 0.332205E+10 | 2191.51 | 03-AUG-17:00 | 34.30 | 24.07 | 0.128775E+09 | 70.29 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.294530E+10 | 2133.86 | 09-SEP-17:02 | 36.18 | 26.62 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.262932E+10 | 1977.01 | 08-OCT-16:07 | 30.67 | 25.13 | 0.128412E+09 | 70.37 | 27-OCT-23:10 | 13.17 | 8.38 |
| November | 0.132722E+10 | 1497.25 | 02-NOV-16:03 | 28.62 | 23.64 | 0.120637E+09 | 70.37 | 30-NOV-21:19 | 15.70 | 12.60 |
| December | 0.103389E+10 | 1291.36 | 15-DEC-17:04 | 27.67 | 21.24 | 0.108712E+09 | 70.31 | 09-DEC-04:00 | 27.67 | 21.24 |
| Annual Sum or Average | 0.229635E+11 | 0.141539E+10 | ||||||||
| Minimum of Months | 0.615410E+09 | 1003.26 | 23.33 | 19.19 | 93628993.84 | 70.28 | 13.17 | 8.38 | ||
| Maximum of Months | 0.332205E+10 | 2191.51 | 36.18 | 26.62 | 0.128775E+09 | 70.37 | 32.50 | 24.86 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.936056E+09 | 6161.69 | 03-JAN-09:02 | 5.50 | 2.10 | 66598711.12 | 178.80 | 19-JAN-08:09 | 19.33 | 19.22 |
| February | 0.843806E+09 | 5672.18 | 10-FEB-09:02 | 17.67 | 16.35 | 63979308.18 | 192.83 | 28-FEB-08:09 | 19.50 | 18.32 |
| March | 0.835616E+09 | 5806.99 | 01-MAR-09:02 | 13.55 | 12.97 | 77172272.97 | 191.21 | 07-MAR-08:09 | 21.47 | 19.93 |
| April | 0.100266E+10 | 6364.23 | 17-APR-08:62 | 16.47 | 11.47 | 69804336.72 | 205.34 | 24-APR-07:10 | 20.32 | 20.32 |
| May | 0.182296E+10 | 5035.29 | 12-MAY-07:02 | 23.98 | 20.89 | 77766358.17 | 218.44 | 09-MAY-07:10 | 23.98 | 20.89 |
| June | 0.195112E+10 | 5118.66 | 07-JUN-07:02 | 22.98 | 19.91 | 77759908.31 | 220.98 | 06-JUN-07:10 | 22.98 | 19.91 |
| July | 0.198000E+10 | 4478.17 | 10-JUL-08:62 | 29.08 | 25.26 | 70713472.68 | 222.29 | 28-JUL-07:10 | 26.28 | 24.22 |
| August | 0.239686E+10 | 4549.84 | 28-AUG-08:62 | 28.17 | 24.26 | 81317455.42 | 221.23 | 18-AUG-07:10 | 28.17 | 24.26 |
| September | 0.203686E+10 | 5007.14 | 22-SEP-07:02 | 21.97 | 19.93 | 70706003.51 | 220.85 | 27-SEP-07:10 | 23.90 | 23.16 |
| October | 0.217604E+10 | 6898.78 | 17-OCT-07:02 | 15.17 | 9.88 | 74116022.38 | 217.47 | 23-OCT-07:10 | 23.33 | 23.11 |
| November | 0.151683E+10 | 6638.50 | 14-NOV-09:02 | 17.47 | 11.27 | 70122697.16 | 217.47 | 06-NOV-08:09 | 17.47 | 11.27 |
| December | 0.111898E+10 | 6591.20 | 01-DEC-09:02 | 15.17 | 12.23 | 67964881.21 | 216.85 | 11-DEC-08:09 | 20.17 | 20.05 |
| Annual Sum or Average | 0.186178E+11 | 0.868021E+09 | ||||||||
| Minimum of Months | 0.835616E+09 | 4478.17 | 5.50 | 2.10 | 63979308.18 | 178.80 | 17.47 | 11.27 | ||
| Maximum of Months | 0.239686E+10 | 6898.78 | 29.08 | 25.26 | 81317455.42 | 222.29 | 28.17 | 24.26 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.709398E+09 | 869.11 | 01-JAN-17:03 | 23.33 | 19.19 | 96596807.32 | 70.35 | 19-JAN-01:10 | 17.58 | 17.50 |
| February | 0.590912E+09 | 765.82 | 27-FEB-17:05 | 24.12 | 20.12 | 93291818.98 | 70.34 | 26-FEB-00:20 | 24.12 | 20.12 |
| March | 0.762950E+09 | 960.78 | 30-MAR-16:05 | 25.42 | 21.24 | 0.109103E+09 | 70.36 | 26-MAR-00:10 | 25.42 | 21.24 |
| April | 0.124723E+10 | 1304.68 | 29-APR-16:07 | 29.80 | 23.87 | 0.121913E+09 | 70.37 | 08-APR-22:00 | 29.80 | 23.87 |
| May | 0.259833E+10 | 1543.18 | 18-MAY-16:50 | 30.05 | 23.53 | 0.128774E+09 | 70.30 | 17-MAY-00:49 | 30.05 | 23.53 |
| June | 0.280843E+10 | 1689.09 | 28-JUN-18:00 | 32.20 | 24.99 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.20 | 24.99 |
| July | 0.318724E+10 | 1928.44 | 19-JUL-13:00 | 33.90 | 25.04 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.334283E+10 | 1961.78 | 03-AUG-17:00 | 34.30 | 24.07 | 0.128775E+09 | 70.29 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.294833E+10 | 1879.41 | 10-SEP-10:30 | 34.05 | 27.54 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.261596E+10 | 1758.15 | 08-OCT-16:07 | 30.67 | 25.13 | 0.128387E+09 | 70.36 | 18-OCT-01:00 | 14.50 | 12.42 |
| November | 0.132025E+10 | 1286.92 | 02-NOV-16:03 | 28.62 | 23.64 | 0.120704E+09 | 70.37 | 24-NOV-21:49 | 18.20 | 14.66 |
| December | 0.994010E+09 | 1073.75 | 16-DEC-13:00 | 28.00 | 22.41 | 0.107938E+09 | 70.36 | 02-DEC-22:49 | 28.00 | 22.41 |
| Annual Sum or Average | 0.231259E+11 | 0.141350E+10 | ||||||||
| Minimum of Months | 0.590912E+09 | 765.82 | 23.33 | 19.19 | 93291818.98 | 70.28 | 14.50 | 12.42 | ||
| Maximum of Months | 0.334283E+10 | 1961.78 | 34.30 | 27.54 | 0.128775E+09 | 70.37 | 33.90 | 25.04 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.834242E+09 | 810.27 | 02-JAN-17:10 | 25.33 | 18.03 | 0.100518E+09 | 70.35 | 18-JAN-02:09 | 19.17 | 17.83 |
| February | 0.692522E+09 | 724.46 | 28-FEB-17:05 | 23.43 | 20.33 | 96403920.60 | 70.35 | 24-FEB-01:39 | 23.43 | 20.33 |
| March | 0.814706E+09 | 832.12 | 30-MAR-16:05 | 25.42 | 21.24 | 0.113077E+09 | 70.37 | 05-MAR-00:10 | 25.42 | 21.24 |
| April | 0.118760E+10 | 1063.70 | 29-APR-16:07 | 29.80 | 23.87 | 0.123412E+09 | 70.36 | 09-APR-20:10 | 29.80 | 23.87 |
| May | 0.223140E+10 | 1262.89 | 25-MAY-17:20 | 32.43 | 23.48 | 0.128774E+09 | 70.30 | 17-MAY-00:49 | 32.43 | 23.48 |
| June | 0.237781E+10 | 1394.16 | 28-JUN-18:00 | 32.20 | 24.99 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.20 | 24.99 |
| July | 0.265172E+10 | 1474.43 | 19-JUL-17:05 | 32.75 | 25.30 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 32.75 | 25.30 |
| August | 0.276283E+10 | 1539.68 | 03-AUG-17:05 | 33.43 | 23.53 | 0.128775E+09 | 70.30 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.248369E+10 | 1488.37 | 09-SEP-17:15 | 35.97 | 26.59 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.223714E+10 | 1401.23 | 08-OCT-16:03 | 30.67 | 25.13 | 0.128627E+09 | 70.34 | 29-OCT-00:10 | 13.83 | 11.18 |
| November | 0.126083E+10 | 1071.30 | 02-NOV-16:03 | 28.62 | 23.64 | 0.122557E+09 | 70.37 | 22-NOV-01:10 | 13.68 | 10.34 |
| December | 0.105566E+10 | 943.35 | 15-DEC-17:04 | 27.67 | 21.24 | 0.112580E+09 | 70.37 | 01-DEC-01:39 | 27.67 | 21.24 |
| Annual Sum or Average | 0.205901E+11 | 0.143274E+10 | ||||||||
| Minimum of Months | 0.692522E+09 | 724.46 | 23.43 | 18.03 | 96403920.60 | 70.28 | 13.68 | 10.34 | ||
| Maximum of Months | 0.276283E+10 | 1539.68 | 35.97 | 26.59 | 0.128775E+09 | 70.37 | 32.75 | 25.30 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.833804E+09 | 808.57 | 02-JAN-17:10 | 25.33 | 18.03 | 0.100499E+09 | 70.35 | 18-JAN-02:30 | 19.50 | 18.15 |
| February | 0.691096E+09 | 720.00 | 28-FEB-17:05 | 23.43 | 20.33 | 96404878.76 | 70.35 | 25-FEB-04:10 | 23.43 | 20.33 |
| March | 0.816150E+09 | 835.99 | 30-MAR-16:05 | 25.42 | 21.24 | 0.113089E+09 | 70.37 | 26-MAR-02:00 | 25.42 | 21.24 |
| April | 0.118882E+10 | 1061.45 | 29-APR-16:07 | 29.80 | 23.87 | 0.123415E+09 | 70.38 | 10-APR-20:10 | 29.80 | 23.87 |
| May | 0.223490E+10 | 1260.84 | 25-MAY-17:20 | 32.43 | 23.48 | 0.128774E+09 | 70.30 | 17-MAY-00:49 | 32.43 | 23.48 |
| June | 0.238012E+10 | 1390.85 | 28-JUN-18:00 | 32.20 | 24.99 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.20 | 24.99 |
| July | 0.265538E+10 | 1474.66 | 19-JUL-17:05 | 32.75 | 25.30 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 32.75 | 25.30 |
| August | 0.276384E+10 | 1536.87 | 03-AUG-17:05 | 33.43 | 23.53 | 0.128775E+09 | 70.30 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.248391E+10 | 1483.86 | 09-SEP-17:15 | 35.97 | 26.59 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.223689E+10 | 1397.75 | 08-OCT-16:03 | 30.67 | 25.13 | 0.128626E+09 | 70.33 | 29-OCT-00:10 | 13.83 | 11.18 |
| November | 0.126203E+10 | 1068.76 | 02-NOV-16:03 | 28.62 | 23.64 | 0.122567E+09 | 70.37 | 30-NOV-21:30 | 15.60 | 12.64 |
| December | 0.105340E+10 | 936.40 | 15-DEC-17:04 | 27.67 | 21.24 | 0.112495E+09 | 70.37 | 02-DEC-01:10 | 27.67 | 21.24 |
| Annual Sum or Average | 0.206003E+11 | 0.143266E+10 | ||||||||
| Minimum of Months | 0.691096E+09 | 720.00 | 23.43 | 18.03 | 96404878.76 | 70.28 | 13.83 | 11.18 | ||
| Maximum of Months | 0.276384E+10 | 1536.87 | 35.97 | 26.59 | 0.128775E+09 | 70.38 | 32.75 | 25.30 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.144026E+10 | 1740.85 | 01-JAN-14:30 | 25.50 | 18.23 | 0.120390E+09 | 70.38 | 14-JAN-19:19 | 12.33 | 10.46 |
| February | 0.123791E+10 | 1396.92 | 27-FEB-15:10 | 26.00 | 20.45 | 0.106816E+09 | 70.37 | 03-FEB-20:30 | 26.00 | 20.45 |
| March | 0.118004E+10 | 1155.93 | 06-MAR-14:00 | 26.60 | 21.65 | 0.114284E+09 | 70.38 | 23-MAR-21:00 | 17.70 | 11.00 |
| April | 0.144929E+10 | 1253.94 | 29-APR-16:07 | 29.80 | 23.87 | 0.123436E+09 | 70.37 | 01-APR-23:30 | 29.80 | 23.87 |
| May | 0.225734E+10 | 1278.37 | 07-MAY-17:17 | 33.13 | 23.08 | 0.125733E+09 | 70.30 | 17-MAY-00:49 | 23.40 | 20.30 |
| June | 0.231357E+10 | 1346.05 | 10-JUN-17:05 | 32.52 | 22.13 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.263396E+10 | 1458.05 | 23-JUL-16:05 | 32.12 | 26.50 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 32.12 | 26.50 |
| August | 0.289763E+10 | 1623.01 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.281467E+10 | 1768.55 | 10-SEP-16:04 | 34.10 | 26.94 | 0.123963E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.293864E+10 | 1982.58 | 09-OCT-14:00 | 31.00 | 23.79 | 0.127493E+09 | 70.36 | 28-OCT-03:30 | 11.50 | 5.93 |
| November | 0.220396E+10 | 1711.53 | 06-NOV-14:30 | 28.30 | 20.80 | 0.123796E+09 | 70.37 | 26-NOV-04:40 | 10.13 | 8.92 |
| December | 0.180791E+10 | 1756.01 | 16-DEC-13:30 | 27.50 | 21.97 | 0.124085E+09 | 70.36 | 05-DEC-00:40 | 27.50 | 21.97 |
| Annual Sum or Average | 0.251752E+11 | 0.146366E+10 | ||||||||
| Minimum of Months | 0.118004E+10 | 1155.93 | 25.50 | 18.23 | 0.106816E+09 | 70.28 | 10.13 | 5.93 | ||
| Maximum of Months | 0.293864E+10 | 1982.58 | 36.07 | 26.94 | 0.129276E+09 | 70.38 | 36.07 | 26.50 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.151522E+10 | 1895.06 | 01-JAN-14:30 | 25.50 | 18.23 | 0.121030E+09 | 70.36 | 16-JAN-03:49 | 14.53 | 13.59 |
| February | 0.129381E+10 | 1457.45 | 27-FEB-15:10 | 26.00 | 20.45 | 0.107218E+09 | 70.38 | 12-FEB-10:30 | 26.00 | 20.45 |
| March | 0.125685E+10 | 1213.63 | 06-MAR-14:00 | 26.60 | 21.65 | 0.114879E+09 | 70.36 | 02-MAR-22:10 | 26.60 | 21.65 |
| April | 0.157912E+10 | 1357.21 | 29-APR-16:07 | 29.80 | 23.87 | 0.123591E+09 | 70.38 | 10-APR-01:10 | 29.80 | 23.87 |
| May | 0.251139E+10 | 1415.69 | 07-MAY-17:20 | 33.13 | 23.08 | 0.125733E+09 | 70.30 | 17-MAY-00:49 | 23.40 | 20.30 |
| June | 0.257408E+10 | 1462.17 | 10-JUN-17:10 | 32.52 | 22.13 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.293693E+10 | 1614.15 | 23-JUL-16:03 | 32.12 | 26.50 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 32.12 | 26.50 |
| August | 0.319176E+10 | 1712.14 | 27-AUG-16:20 | 33.33 | 24.08 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 33.33 | 24.08 |
| September | 0.309678E+10 | 1926.91 | 10-SEP-16:04 | 34.10 | 26.94 | 0.123963E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.321144E+10 | 2160.00 | 09-OCT-14:00 | 31.00 | 23.79 | 0.127505E+09 | 70.36 | 28-OCT-04:40 | 10.33 | 5.61 |
| November | 0.236521E+10 | 1810.21 | 06-NOV-14:20 | 28.30 | 20.91 | 0.123868E+09 | 70.37 | 26-NOV-06:10 | 9.40 | 8.24 |
| December | 0.191260E+10 | 1867.96 | 10-DEC-14:40 | 27.67 | 20.09 | 0.124598E+09 | 70.37 | 26-DEC-22:49 | 10.25 | 7.30 |
| Annual Sum or Average | 0.274452E+11 | 0.146605E+10 | ||||||||
| Minimum of Months | 0.125685E+10 | 1213.63 | 25.50 | 18.23 | 0.107218E+09 | 70.28 | 9.40 | 5.61 | ||
| Maximum of Months | 0.321144E+10 | 2160.00 | 34.10 | 26.94 | 0.129276E+09 | 70.38 | 33.33 | 26.50 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.141160E+10 | 2293.81 | 01-JAN-15:20 | 25.00 | 18.55 | 0.112061E+09 | 70.32 | 02-JAN-23:49 | 11.17 | 8.31 |
| February | 0.148370E+10 | 2201.75 | 27-FEB-16:10 | 25.32 | 20.49 | 0.104439E+09 | 70.32 | 07-FEB-20:10 | 25.32 | 20.49 |
| March | 0.156633E+10 | 2001.63 | 06-MAR-16:10 | 25.92 | 21.45 | 0.113595E+09 | 70.31 | 15-MAR-23:00 | 15.40 | 15.00 |
| April | 0.219438E+10 | 2275.16 | 29-APR-16:10 | 29.80 | 23.87 | 0.123430E+09 | 70.31 | 09-APR-06:00 | 29.80 | 23.87 |
| May | 0.317274E+10 | 2240.45 | 10-MAY-16:30 | 32.50 | 22.86 | 0.125733E+09 | 70.30 | 17-MAY-00:49 | 23.40 | 20.30 |
| June | 0.319760E+10 | 2309.14 | 10-JUN-17:00 | 32.80 | 22.02 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.336295E+10 | 2247.00 | 22-JUL-16:30 | 35.55 | 26.93 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 35.55 | 26.93 |
| August | 0.341836E+10 | 2483.69 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.318136E+10 | 2595.30 | 10-SEP-16:10 | 34.10 | 26.94 | 0.123963E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.321511E+10 | 2733.99 | 08-OCT-15:30 | 31.00 | 25.48 | 0.127015E+09 | 70.32 | 27-OCT-22:49 | 13.00 | 8.54 |
| November | 0.217766E+10 | 2382.74 | 02-NOV-15:20 | 29.20 | 23.96 | 0.121814E+09 | 70.32 | 17-NOV-01:10 | 15.13 | 11.33 |
| December | 0.173967E+10 | 2416.98 | 10-DEC-15:30 | 27.50 | 20.13 | 0.117053E+09 | 70.30 | 08-DEC-01:39 | 27.50 | 20.13 |
| Annual Sum or Average | 0.301215E+11 | 0.144276E+10 | ||||||||
| Minimum of Months | 0.141160E+10 | 2001.63 | 25.00 | 18.55 | 0.104439E+09 | 70.28 | 11.17 | 8.31 | ||
| Maximum of Months | 0.341836E+10 | 2733.99 | 36.07 | 26.94 | 0.129276E+09 | 70.32 | 36.07 | 26.93 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.733715E+09 | 1212.10 | 19-JAN-16:20 | 24.67 | 20.76 | 97393713.27 | 70.31 | 01-JAN-05:40 | 24.67 | 20.76 |
| February | 0.862349E+09 | 1413.20 | 27-FEB-17:10 | 24.12 | 20.12 | 98437946.02 | 70.31 | 02-FEB-06:10 | 24.12 | 20.12 |
| March | 0.114958E+10 | 1554.17 | 26-MAR-16:20 | 25.90 | 20.05 | 0.114598E+09 | 70.30 | 01-MAR-03:49 | 25.90 | 20.05 |
| April | 0.191962E+10 | 2044.66 | 29-APR-16:20 | 29.60 | 23.75 | 0.123737E+09 | 70.32 | 09-APR-23:00 | 29.60 | 23.75 |
| May | 0.315122E+10 | 2208.98 | 10-MAY-16:30 | 32.50 | 22.86 | 0.128774E+09 | 70.30 | 17-MAY-00:49 | 23.40 | 20.30 |
| June | 0.326510E+10 | 2353.01 | 28-JUN-17:25 | 32.50 | 24.86 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.50 | 24.86 |
| July | 0.338175E+10 | 2310.32 | 07-JUL-16:30 | 33.60 | 24.99 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 23.30 | 22.94 |
| August | 0.327927E+10 | 2376.24 | 03-AUG-16:50 | 34.50 | 24.19 | 0.128775E+09 | 70.29 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.284485E+10 | 2310.66 | 09-SEP-17:04 | 36.18 | 26.62 | 0.124621E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.250167E+10 | 2103.91 | 08-OCT-16:10 | 30.67 | 25.13 | 0.127829E+09 | 70.30 | 26-OCT-04:40 | 23.33 | 14.78 |
| November | 0.126791E+10 | 1630.46 | 02-NOV-16:03 | 28.62 | 23.64 | 0.118748E+09 | 70.32 | 09-NOV-23:10 | 16.35 | 13.00 |
| December | 0.982130E+09 | 1419.70 | 13-DEC-16:10 | 28.67 | 20.87 | 0.106724E+09 | 70.30 | 02-DEC-22:49 | 28.67 | 20.87 |
| Annual Sum or Average | 0.253392E+11 | 0.142303E+10 | ||||||||
| Minimum of Months | 0.733715E+09 | 1212.10 | 24.12 | 20.05 | 97393713.27 | 70.28 | 16.35 | 13.00 | ||
| Maximum of Months | 0.338175E+10 | 2376.24 | 36.18 | 26.62 | 0.128775E+09 | 70.32 | 32.50 | 24.86 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.138621E+10 | 2176.78 | 01-JAN-14:00 | 26.00 | 17.88 | 0.111904E+09 | 70.30 | 20-JAN-07:10 | 17.00 | 17.00 |
| February | 0.145685E+10 | 1926.57 | 02-FEB-13:30 | 28.00 | 20.71 | 0.104275E+09 | 70.31 | 26-FEB-05:30 | 13.60 | 13.60 |
| March | 0.159805E+10 | 1822.59 | 06-MAR-13:00 | 27.20 | 21.71 | 0.113403E+09 | 70.31 | 17-MAR-04:49 | 15.88 | 15.30 |
| April | 0.219190E+10 | 1934.72 | 29-APR-16:10 | 29.80 | 23.87 | 0.123400E+09 | 70.31 | 01-APR-22:49 | 29.80 | 23.87 |
| May | 0.325615E+10 | 1922.32 | 18-MAY-16:40 | 30.70 | 23.58 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 30.70 | 23.58 |
| June | 0.325345E+10 | 1988.16 | 10-JUN-16:30 | 33.35 | 21.77 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.345200E+10 | 2241.67 | 19-JUL-13:00 | 33.90 | 25.04 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.343982E+10 | 2111.68 | 03-AUG-16:10 | 35.30 | 24.68 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 23.67 | 22.51 |
| September | 0.318468E+10 | 2364.32 | 10-SEP-12:00 | 35.20 | 27.76 | 0.123963E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.319810E+10 | 2655.46 | 09-OCT-14:00 | 31.00 | 23.79 | 0.126987E+09 | 70.31 | 30-OCT-04:10 | 16.83 | 14.48 |
| November | 0.217760E+10 | 2186.66 | 07-NOV-13:30 | 28.30 | 24.43 | 0.121828E+09 | 70.31 | 22-NOV-00:20 | 14.20 | 11.24 |
| December | 0.168306E+10 | 2261.85 | 16-DEC-13:30 | 27.50 | 21.97 | 0.116669E+09 | 70.32 | 03-DEC-09:39 | 27.50 | 21.97 |
| Annual Sum or Average | 0.302779E+11 | 0.144182E+10 | ||||||||
| Minimum of Months | 0.138621E+10 | 1822.59 | 26.00 | 17.88 | 0.104275E+09 | 70.28 | 13.60 | 11.24 | ||
| Maximum of Months | 0.345200E+10 | 2655.46 | 35.30 | 27.76 | 0.129276E+09 | 70.32 | 33.90 | 25.04 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.722096E+09 | 1012.08 | 19-JAN-12:00 | 26.00 | 21.87 | 96817258.18 | 70.27 | 19-JAN-22:19 | 21.00 | 21.00 |
| February | 0.832491E+09 | 1087.15 | 24-FEB-13:00 | 27.70 | 21.49 | 98174178.58 | 70.30 | 24-FEB-05:49 | 27.70 | 21.49 |
| March | 0.117854E+10 | 1338.73 | 28-MAR-16:05 | 25.72 | 22.03 | 0.114428E+09 | 70.30 | 25-MAR-02:39 | 25.72 | 22.03 |
| April | 0.191454E+10 | 1710.17 | 29-APR-16:10 | 29.80 | 23.87 | 0.123735E+09 | 70.31 | 04-APR-02:00 | 29.80 | 23.87 |
| May | 0.323471E+10 | 1903.32 | 18-MAY-16:50 | 30.05 | 23.53 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 30.05 | 23.53 |
| June | 0.332117E+10 | 2005.76 | 28-JUN-18:00 | 32.20 | 24.99 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.20 | 24.99 |
| July | 0.347089E+10 | 2236.28 | 19-JUL-13:00 | 33.90 | 25.04 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.330071E+10 | 2062.99 | 03-AUG-16:17 | 35.10 | 24.56 | 0.128775E+09 | 70.29 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.284812E+10 | 1984.54 | 10-SEP-10:10 | 33.82 | 27.46 | 0.124621E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.248457E+10 | 1814.15 | 08-OCT-16:10 | 30.67 | 25.13 | 0.127762E+09 | 70.32 | 27-OCT-01:30 | 14.50 | 8.59 |
| November | 0.125782E+10 | 1342.88 | 02-NOV-16:03 | 28.62 | 23.64 | 0.118770E+09 | 70.31 | 20-NOV-03:09 | 16.48 | 14.29 |
| December | 0.939830E+09 | 1150.78 | 16-DEC-13:00 | 28.00 | 22.41 | 0.105854E+09 | 70.31 | 09-DEC-05:30 | 28.00 | 22.41 |
| Annual Sum or Average | 0.255055E+11 | 0.142111E+10 | ||||||||
| Minimum of Months | 0.722096E+09 | 1012.08 | 25.72 | 21.49 | 96817258.18 | 70.27 | 14.50 | 8.59 | ||
| Maximum of Months | 0.347089E+10 | 2236.28 | 35.10 | 27.46 | 0.128775E+09 | 70.32 | 33.90 | 25.04 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.899113E+09 | 868.15 | 02-JAN-17:10 | 25.33 | 18.03 | 0.101268E+09 | 70.29 | 20-JAN-06:19 | 17.00 | 17.00 |
| February | 0.904706E+09 | 902.72 | 24-FEB-17:03 | 24.12 | 20.85 | 0.101638E+09 | 70.30 | 12-FEB-01:49 | 24.12 | 20.85 |
| March | 0.116031E+10 | 1086.66 | 28-MAR-16:05 | 25.72 | 22.03 | 0.117915E+09 | 70.31 | 03-MAR-23:30 | 25.72 | 22.03 |
| April | 0.167767E+10 | 1316.53 | 29-APR-16:10 | 29.80 | 23.87 | 0.124353E+09 | 70.31 | 17-APR-03:49 | 29.80 | 23.87 |
| May | 0.261792E+10 | 1485.90 | 25-MAY-17:25 | 32.25 | 23.56 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 32.25 | 23.56 |
| June | 0.267139E+10 | 1586.95 | 28-JUN-18:00 | 32.20 | 24.99 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.20 | 24.99 |
| July | 0.278807E+10 | 1575.60 | 19-JUL-17:10 | 32.75 | 25.30 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 32.75 | 25.30 |
| August | 0.268934E+10 | 1573.96 | 03-AUG-17:05 | 33.43 | 23.53 | 0.128775E+09 | 70.29 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.238572E+10 | 1513.98 | 09-SEP-17:04 | 36.18 | 26.62 | 0.124621E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.212247E+10 | 1418.39 | 08-OCT-16:10 | 30.67 | 25.13 | 0.128403E+09 | 70.32 | 28-OCT-22:49 | 15.00 | 12.15 |
| November | 0.123740E+10 | 1102.16 | 02-NOV-16:05 | 28.62 | 23.64 | 0.121804E+09 | 70.32 | 13-NOV-23:49 | 16.45 | 13.89 |
| December | 0.104199E+10 | 981.06 | 15-DEC-17:20 | 27.33 | 21.24 | 0.111577E+09 | 70.32 | 01-DEC-01:10 | 27.33 | 21.24 |
| Annual Sum or Average | 0.221961E+11 | 0.144252E+10 | ||||||||
| Minimum of Months | 0.899113E+09 | 868.15 | 24.12 | 18.03 | 0.101268E+09 | 70.28 | 15.00 | 12.15 | ||
| Maximum of Months | 0.278807E+10 | 1586.95 | 36.18 | 26.62 | 0.128775E+09 | 70.32 | 32.75 | 25.30 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.898465E+09 | 866.03 | 02-JAN-17:10 | 25.33 | 18.03 | 0.101231E+09 | 70.32 | 03-JAN-00:10 | 10.83 | 7.94 |
| February | 0.903705E+09 | 898.46 | 24-FEB-17:03 | 24.12 | 20.85 | 0.101642E+09 | 70.31 | 20-FEB-23:49 | 24.12 | 20.85 |
| March | 0.116216E+10 | 1089.06 | 28-MAR-16:05 | 25.72 | 22.03 | 0.117942E+09 | 70.31 | 05-MAR-05:40 | 25.72 | 22.03 |
| April | 0.167875E+10 | 1313.94 | 29-APR-16:10 | 29.80 | 23.87 | 0.124353E+09 | 70.31 | 17-APR-05:00 | 29.80 | 23.87 |
| May | 0.262103E+10 | 1482.71 | 25-MAY-17:25 | 32.25 | 23.56 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 32.25 | 23.56 |
| June | 0.267349E+10 | 1582.52 | 28-JUN-18:00 | 32.20 | 24.99 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.20 | 24.99 |
| July | 0.279131E+10 | 1575.54 | 19-JUL-17:10 | 32.75 | 25.30 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 32.75 | 25.30 |
| August | 0.269028E+10 | 1570.39 | 03-AUG-17:05 | 33.43 | 23.53 | 0.128775E+09 | 70.29 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.238597E+10 | 1508.50 | 09-SEP-17:04 | 36.18 | 26.62 | 0.124621E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.212219E+10 | 1414.23 | 08-OCT-16:10 | 30.67 | 25.13 | 0.128401E+09 | 70.32 | 28-OCT-22:49 | 15.00 | 12.15 |
| November | 0.123899E+10 | 1099.44 | 02-NOV-16:05 | 28.62 | 23.64 | 0.121814E+09 | 70.32 | 25-NOV-02:09 | 16.42 | 14.46 |
| December | 0.103981E+10 | 973.41 | 15-DEC-17:20 | 27.33 | 21.24 | 0.111478E+09 | 70.30 | 01-DEC-01:10 | 27.33 | 21.24 |
| Annual Sum or Average | 0.222061E+11 | 0.144243E+10 | ||||||||
| Minimum of Months | 0.898465E+09 | 866.03 | 24.12 | 18.03 | 0.101231E+09 | 70.28 | 10.83 | 7.94 | ||
| Maximum of Months | 0.279131E+10 | 1582.52 | 36.18 | 26.62 | 0.128775E+09 | 70.32 | 32.75 | 25.30 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.158081E+10 | 2001.62 | 01-JAN-14:30 | 25.50 | 18.23 | 0.120425E+09 | 70.31 | 14-JAN-20:49 | 10.98 | 10.39 |
| February | 0.156971E+10 | 1715.56 | 27-FEB-15:10 | 26.00 | 20.45 | 0.108966E+09 | 70.31 | 12-FEB-09:30 | 26.00 | 20.45 |
| March | 0.159271E+10 | 1545.55 | 05-MAR-13:40 | 27.70 | 18.32 | 0.117176E+09 | 70.31 | 04-MAR-04:40 | 27.70 | 18.32 |
| April | 0.196097E+10 | 1539.43 | 29-APR-16:07 | 29.80 | 23.87 | 0.123907E+09 | 70.32 | 03-APR-01:00 | 29.80 | 23.87 |
| May | 0.263965E+10 | 1475.34 | 18-MAY-16:40 | 30.70 | 23.58 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 30.70 | 23.58 |
| June | 0.260334E+10 | 1541.16 | 10-JUN-16:50 | 32.98 | 21.94 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.276910E+10 | 1566.87 | 23-JUL-16:05 | 32.12 | 26.50 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 32.12 | 26.50 |
| August | 0.282889E+10 | 1669.51 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.272469E+10 | 1812.28 | 10-SEP-16:08 | 34.10 | 26.94 | 0.123963E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.285298E+10 | 2145.70 | 09-OCT-14:00 | 31.00 | 23.79 | 0.127393E+09 | 70.30 | 26-OCT-04:40 | 23.33 | 14.78 |
| November | 0.222205E+10 | 1894.79 | 06-NOV-14:20 | 28.30 | 20.91 | 0.123394E+09 | 70.32 | 12-NOV-04:10 | 11.40 | 8.31 |
| December | 0.186817E+10 | 2027.51 | 10-DEC-14:30 | 27.50 | 20.13 | 0.122671E+09 | 70.32 | 18-DEC-00:10 | 7.67 | 4.70 |
| Annual Sum or Average | 0.272131E+11 | 0.146729E+10 | ||||||||
| Minimum of Months | 0.156971E+10 | 1475.34 | 25.50 | 18.23 | 0.108966E+09 | 70.28 | 7.67 | 4.70 | ||
| Maximum of Months | 0.285298E+10 | 2145.70 | 36.07 | 26.94 | 0.129276E+09 | 70.32 | 36.07 | 26.50 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.158238E+10 | 2003.48 | 01-JAN-14:30 | 25.50 | 18.23 | 0.120428E+09 | 70.32 | 12-JAN-22:10 | 11.40 | 10.46 |
| February | 0.156985E+10 | 1715.22 | 27-FEB-15:10 | 26.00 | 20.45 | 0.108959E+09 | 70.31 | 20-FEB-01:10 | 26.00 | 20.45 |
| March | 0.159539E+10 | 1549.07 | 05-MAR-13:40 | 27.70 | 18.32 | 0.117186E+09 | 70.31 | 08-MAR-02:30 | 13.90 | 12.30 |
| April | 0.196180E+10 | 1536.68 | 29-APR-16:07 | 29.80 | 23.87 | 0.123906E+09 | 70.31 | 02-APR-01:39 | 29.80 | 23.87 |
| May | 0.264277E+10 | 1474.12 | 18-MAY-16:40 | 30.70 | 23.58 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 30.70 | 23.58 |
| June | 0.260547E+10 | 1537.62 | 10-JUN-16:50 | 32.98 | 21.94 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.277235E+10 | 1569.58 | 23-JUL-16:05 | 32.12 | 26.50 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 32.12 | 26.50 |
| August | 0.282982E+10 | 1666.43 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.272493E+10 | 1809.08 | 10-SEP-16:08 | 34.10 | 26.94 | 0.123963E+09 | 70.29 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.285268E+10 | 2148.10 | 09-OCT-14:00 | 31.00 | 23.79 | 0.127391E+09 | 70.32 | 29-OCT-05:00 | 14.00 | 11.76 |
| November | 0.222306E+10 | 1896.64 | 06-NOV-14:20 | 28.30 | 20.91 | 0.123393E+09 | 70.32 | 12-NOV-04:10 | 11.40 | 8.31 |
| December | 0.186627E+10 | 2028.94 | 10-DEC-14:30 | 27.50 | 20.13 | 0.122636E+09 | 70.32 | 24-DEC-23:30 | 11.00 | 10.74 |
| Annual Sum or Average | 0.272268E+11 | 0.146726E+10 | ||||||||
| Minimum of Months | 0.156985E+10 | 1474.12 | 25.50 | 18.23 | 0.108959E+09 | 70.28 | 11.00 | 8.31 | ||
| Maximum of Months | 0.285268E+10 | 2148.10 | 36.07 | 26.94 | 0.129276E+09 | 70.32 | 36.07 | 26.50 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.105210E+10 | 2983.95 | 01-JAN-15:10 | 25.00 | 18.55 | 99406358.03 | 70.30 | 18-JAN-00:00 | 19.00 | 17.67 |
| February | 0.123775E+10 | 2864.02 | 27-FEB-16:10 | 25.32 | 20.49 | 94323358.83 | 70.36 | 07-FEB-20:19 | 25.32 | 20.49 |
| March | 0.137985E+10 | 2626.61 | 26-MAR-16:10 | 26.00 | 20.08 | 0.104339E+09 | 70.36 | 25-MAR-00:30 | 26.00 | 20.08 |
| April | 0.218037E+10 | 3139.94 | 29-APR-16:07 | 29.80 | 23.87 | 0.118483E+09 | 70.36 | 02-APR-20:30 | 29.80 | 23.87 |
| May | 0.361098E+10 | 3202.62 | 10-MAY-16:15 | 32.60 | 22.94 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 23.40 | 20.23 |
| June | 0.372475E+10 | 3240.09 | 10-JUN-16:40 | 33.17 | 21.86 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.389974E+10 | 3253.44 | 22-JUL-16:30 | 35.55 | 26.93 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 35.55 | 26.93 |
| August | 0.392773E+10 | 3520.64 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.349849E+10 | 3630.76 | 10-SEP-16:04 | 34.10 | 26.94 | 0.123963E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.342489E+10 | 3736.25 | 08-OCT-15:30 | 31.00 | 25.48 | 0.124063E+09 | 70.36 | 02-OCT-03:20 | 31.00 | 25.48 |
| November | 0.189205E+10 | 3259.82 | 02-NOV-15:10 | 29.30 | 24.05 | 0.110490E+09 | 70.37 | 09-NOV-20:19 | 17.23 | 12.81 |
| December | 0.141585E+10 | 3158.53 | 10-DEC-15:10 | 27.83 | 20.05 | 0.105137E+09 | 70.35 | 06-DEC-18:40 | 27.83 | 20.05 |
| Annual Sum or Average | 0.312445E+11 | 0.137960E+10 | ||||||||
| Minimum of Months | 0.105210E+10 | 2626.61 | 25.00 | 18.55 | 94323358.83 | 70.28 | 17.23 | 12.81 | ||
| Maximum of Months | 0.392773E+10 | 3736.25 | 36.07 | 26.94 | 0.129276E+09 | 70.37 | 36.07 | 26.93 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.469125E+09 | 1600.90 | 31-JAN-16:20 | 24.33 | 21.34 | 92769177.20 | 70.34 | 31-JAN-01:39 | 24.33 | 21.34 |
| February | 0.660183E+09 | 1771.08 | 27-FEB-17:05 | 24.12 | 20.12 | 91350497.31 | 70.34 | 23-FEB-23:00 | 24.12 | 20.12 |
| March | 0.983398E+09 | 2122.31 | 26-MAR-16:10 | 26.00 | 20.08 | 0.105667E+09 | 70.36 | 14-MAR-20:19 | 26.00 | 20.08 |
| April | 0.189340E+10 | 2891.22 | 28-APR-16:04 | 32.02 | 25.39 | 0.118381E+09 | 70.34 | 06-APR-02:00 | 32.02 | 25.39 |
| May | 0.358807E+10 | 3138.41 | 10-MAY-16:30 | 32.50 | 22.86 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 23.40 | 20.23 |
| June | 0.379546E+10 | 3243.36 | 28-JUN-17:25 | 32.50 | 24.86 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.50 | 24.86 |
| July | 0.392122E+10 | 3278.08 | 07-JUL-16:30 | 33.60 | 24.99 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 23.30 | 22.94 |
| August | 0.376998E+10 | 3360.15 | 03-AUG-16:30 | 34.90 | 24.44 | 0.128775E+09 | 70.30 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.313075E+10 | 3227.90 | 09-SEP-16:50 | 36.27 | 26.61 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.266609E+10 | 2862.82 | 08-OCT-16:07 | 30.67 | 25.13 | 0.124634E+09 | 70.35 | 02-OCT-02:09 | 30.67 | 25.13 |
| November | 0.102456E+10 | 2186.69 | 02-NOV-16:03 | 28.62 | 23.64 | 0.106730E+09 | 70.34 | 20-NOV-23:00 | 18.20 | 16.56 |
| December | 0.679082E+09 | 1880.85 | 13-DEC-16:10 | 28.67 | 20.87 | 98611928.32 | 70.33 | 14-DEC-06:10 | 20.00 | 20.00 |
| Annual Sum or Average | 0.265813E+11 | 0.137371E+10 | ||||||||
| Minimum of Months | 0.469125E+09 | 1600.90 | 24.12 | 20.08 | 91350497.31 | 70.28 | 18.20 | 16.56 | ||
| Maximum of Months | 0.392122E+10 | 3360.15 | 36.27 | 26.61 | 0.128775E+09 | 70.36 | 32.50 | 25.39 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.101434E+10 | 2823.18 | 01-JAN-14:20 | 25.67 | 18.12 | 98960890.26 | 70.33 | 31-JAN-03:49 | 19.00 | 19.00 |
| February | 0.120131E+10 | 2543.36 | 27-FEB-14:30 | 25.80 | 20.17 | 93815928.36 | 70.35 | 11-FEB-23:10 | 25.80 | 20.17 |
| March | 0.140252E+10 | 2409.44 | 06-MAR-13:40 | 26.80 | 21.67 | 0.104011E+09 | 70.37 | 22-MAR-18:30 | 14.10 | 9.00 |
| April | 0.216480E+10 | 2700.87 | 28-APR-15:10 | 33.12 | 23.52 | 0.118280E+09 | 70.36 | 18-APR-02:20 | 33.12 | 23.52 |
| May | 0.369753E+10 | 2764.74 | 07-MAY-14:00 | 33.90 | 23.76 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 23.40 | 20.23 |
| June | 0.378589E+10 | 2757.05 | 10-JUN-16:30 | 33.35 | 21.77 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.399764E+10 | 3194.03 | 19-JUL-13:00 | 33.90 | 25.04 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.394842E+10 | 2979.18 | 03-AUG-16:10 | 35.30 | 24.68 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 23.67 | 22.51 |
| September | 0.350107E+10 | 3405.56 | 10-SEP-13:00 | 35.00 | 27.79 | 0.123963E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.339899E+10 | 3586.71 | 09-OCT-14:00 | 31.00 | 23.79 | 0.123946E+09 | 70.36 | 02-OCT-02:49 | 31.00 | 23.79 |
| November | 0.187637E+10 | 3051.48 | 02-NOV-13:30 | 29.70 | 24.41 | 0.110500E+09 | 70.38 | 30-NOV-22:10 | 15.22 | 12.81 |
| December | 0.135156E+10 | 3002.88 | 16-DEC-13:30 | 27.50 | 21.97 | 0.104736E+09 | 70.34 | 13-DEC-02:30 | 27.50 | 21.97 |
| Annual Sum or Average | 0.313404E+11 | 0.137761E+10 | ||||||||
| Minimum of Months | 0.101434E+10 | 2409.44 | 25.67 | 18.12 | 93815928.36 | 70.28 | 14.10 | 9.00 | ||
| Maximum of Months | 0.399764E+10 | 3586.71 | 35.30 | 27.79 | 0.129276E+09 | 70.38 | 33.90 | 25.04 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.436531E+09 | 1251.59 | 19-JAN-12:50 | 25.17 | 21.60 | 92073954.69 | 70.31 | 01-JAN-23:49 | 25.17 | 21.60 |
| February | 0.627817E+09 | 1366.69 | 24-FEB-14:00 | 27.20 | 21.39 | 90666035.59 | 70.35 | 26-FEB-23:00 | 17.80 | 17.48 |
| March | 0.100615E+10 | 1883.44 | 26-MAR-14:10 | 28.97 | 20.05 | 0.105198E+09 | 70.34 | 01-MAR-00:10 | 28.97 | 20.05 |
| April | 0.187557E+10 | 2383.23 | 28-APR-15:10 | 33.12 | 23.52 | 0.118176E+09 | 70.35 | 18-APR-02:09 | 33.12 | 23.52 |
| May | 0.367501E+10 | 2601.30 | 18-MAY-16:30 | 31.35 | 23.60 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 31.35 | 23.60 |
| June | 0.385712E+10 | 2719.78 | 28-JUN-15:10 | 33.30 | 25.80 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 33.30 | 25.80 |
| July | 0.401939E+10 | 3170.01 | 19-JUL-13:00 | 33.90 | 25.04 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.379066E+10 | 2885.77 | 03-AUG-16:08 | 35.30 | 24.68 | 0.128775E+09 | 70.30 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.313322E+10 | 2807.61 | 10-SEP-12:00 | 35.20 | 27.76 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.264519E+10 | 2495.06 | 07-OCT-13:00 | 33.00 | 26.99 | 0.124334E+09 | 70.32 | 19-OCT-01:49 | 20.83 | 17.69 |
| November | 0.101217E+10 | 1821.59 | 02-NOV-14:10 | 29.40 | 24.42 | 0.106210E+09 | 70.35 | 20-NOV-23:00 | 18.20 | 16.56 |
| December | 0.629571E+09 | 1517.80 | 16-DEC-13:00 | 28.00 | 22.41 | 97775470.09 | 70.35 | 10-DEC-00:00 | 28.00 | 22.41 |
| Annual Sum or Average | 0.267084E+11 | 0.137000E+10 | ||||||||
| Minimum of Months | 0.436531E+09 | 1251.59 | 25.17 | 20.05 | 90666035.59 | 70.28 | 17.80 | 16.56 | ||
| Maximum of Months | 0.401939E+10 | 3170.01 | 35.30 | 27.76 | 0.128775E+09 | 70.35 | 33.90 | 25.80 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.466747E+09 | 1082.10 | 31-JAN-16:10 | 24.67 | 21.45 | 93903649.80 | 70.34 | 29-JAN-21:10 | 24.67 | 21.45 |
| February | 0.602424E+09 | 1095.18 | 27-FEB-16:10 | 25.32 | 20.49 | 93044945.43 | 70.34 | 27-FEB-00:49 | 25.32 | 20.49 |
| March | 0.900215E+09 | 1477.07 | 26-MAR-16:20 | 25.90 | 20.05 | 0.107610E+09 | 70.36 | 04-MAR-21:19 | 25.90 | 20.05 |
| April | 0.160287E+10 | 1932.45 | 28-APR-16:04 | 32.02 | 25.39 | 0.120117E+09 | 70.36 | 13-APR-00:20 | 32.02 | 25.39 |
| May | 0.301609E+10 | 2118.14 | 28-MAY-16:30 | 32.50 | 24.77 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 32.50 | 24.77 |
| June | 0.315782E+10 | 2224.84 | 28-JUN-17:30 | 32.50 | 24.86 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.50 | 24.86 |
| July | 0.328652E+10 | 2294.45 | 19-JUL-13:00 | 33.90 | 25.04 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.313267E+10 | 2290.30 | 03-AUG-16:17 | 35.10 | 24.56 | 0.128775E+09 | 70.30 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.264260E+10 | 2168.80 | 09-SEP-16:40 | 36.13 | 26.58 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.224408E+10 | 1962.38 | 08-OCT-16:03 | 30.67 | 25.13 | 0.125444E+09 | 70.35 | 31-OCT-02:49 | 19.00 | 17.10 |
| November | 0.954305E+09 | 1469.65 | 02-NOV-16:05 | 28.62 | 23.64 | 0.109044E+09 | 70.36 | 19-NOV-21:49 | 17.70 | 14.66 |
| December | 0.654340E+09 | 1250.94 | 15-DEC-15:10 | 28.83 | 21.51 | 99984920.23 | 70.30 | 09-DEC-01:19 | 28.83 | 21.51 |
| Annual Sum or Average | 0.226607E+11 | 0.138471E+10 | ||||||||
| Minimum of Months | 0.466747E+09 | 1082.10 | 24.67 | 20.05 | 93044945.43 | 70.28 | 17.70 | 14.66 | ||
| Maximum of Months | 0.328652E+10 | 2294.45 | 36.13 | 26.58 | 0.128775E+09 | 70.36 | 33.90 | 25.39 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.465770E+09 | 1074.12 | 31-JAN-16:10 | 24.67 | 21.45 | 93849077.80 | 70.35 | 18-JAN-03:20 | 24.67 | 21.45 |
| February | 0.601933E+09 | 1088.38 | 27-FEB-16:10 | 25.32 | 20.49 | 92984664.14 | 70.34 | 26-FEB-00:10 | 25.32 | 20.49 |
| March | 0.903125E+09 | 1471.60 | 26-MAR-16:10 | 26.00 | 20.08 | 0.107578E+09 | 70.34 | 31-MAR-03:09 | 17.25 | 17.25 |
| April | 0.160465E+10 | 1922.11 | 28-APR-16:04 | 32.02 | 25.39 | 0.120092E+09 | 70.35 | 20-APR-03:49 | 32.02 | 25.39 |
| May | 0.301987E+10 | 2108.32 | 28-MAY-16:30 | 32.50 | 24.77 | 0.128774E+09 | 70.30 | 12-MAY-02:49 | 32.50 | 24.77 |
| June | 0.316052E+10 | 2213.09 | 28-JUN-17:30 | 32.50 | 24.86 | 0.124621E+09 | 70.30 | 11-JUN-02:49 | 32.50 | 24.86 |
| July | 0.329044E+10 | 2303.97 | 19-JUL-13:00 | 33.90 | 25.04 | 0.128775E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.313381E+10 | 2282.14 | 03-AUG-16:17 | 35.10 | 24.56 | 0.128775E+09 | 70.30 | 19-AUG-05:19 | 23.57 | 23.36 |
| September | 0.264302E+10 | 2157.41 | 09-SEP-16:40 | 36.13 | 26.58 | 0.124621E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.224394E+10 | 1952.18 | 08-OCT-16:03 | 30.67 | 25.13 | 0.125409E+09 | 70.38 | 26-OCT-23:00 | 16.30 | 9.90 |
| November | 0.955384E+09 | 1464.28 | 02-NOV-15:10 | 29.30 | 24.05 | 0.108989E+09 | 70.35 | 06-NOV-06:10 | 18.80 | 17.70 |
| December | 0.652500E+09 | 1243.92 | 15-DEC-15:10 | 28.83 | 21.51 | 99896919.97 | 70.28 | 09-DEC-01:19 | 28.83 | 21.51 |
| Annual Sum or Average | 0.226750E+11 | 0.138436E+10 | ||||||||
| Minimum of Months | 0.465770E+09 | 1074.12 | 24.67 | 20.08 | 92984664.14 | 70.28 | 16.30 | 9.90 | ||
| Maximum of Months | 0.329044E+10 | 2303.97 | 36.13 | 26.58 | 0.128775E+09 | 70.38 | 33.90 | 25.39 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.111194E+10 | 2635.07 | 01-JAN-14:30 | 25.50 | 18.23 | 0.103097E+09 | 70.35 | 02-JAN-03:39 | 16.67 | 16.05 |
| February | 0.121376E+10 | 2293.31 | 27-FEB-14:40 | 25.90 | 20.26 | 97575525.09 | 70.36 | 19-FEB-19:30 | 25.90 | 20.26 |
| March | 0.130773E+10 | 2034.53 | 06-MAR-14:20 | 26.43 | 21.45 | 0.107170E+09 | 70.35 | 13-MAR-19:00 | 13.30 | 9.25 |
| April | 0.189384E+10 | 2220.09 | 28-APR-15:10 | 33.12 | 23.52 | 0.120377E+09 | 70.37 | 03-APR-23:49 | 33.12 | 23.52 |
| May | 0.303902E+10 | 2179.72 | 10-MAY-16:04 | 32.70 | 23.02 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 23.40 | 20.23 |
| June | 0.308602E+10 | 2238.20 | 10-JUN-16:30 | 33.35 | 21.77 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.326480E+10 | 2323.81 | 22-JUL-16:17 | 35.73 | 26.98 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 35.73 | 26.98 |
| August | 0.329163E+10 | 2452.40 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.301408E+10 | 2710.08 | 10-SEP-13:50 | 35.67 | 27.34 | 0.123963E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.301199E+10 | 2972.06 | 09-OCT-14:00 | 31.00 | 23.79 | 0.125124E+09 | 70.34 | 31-OCT-03:49 | 18.17 | 16.77 |
| November | 0.185691E+10 | 2647.78 | 02-NOV-14:10 | 29.40 | 24.42 | 0.114162E+09 | 70.36 | 20-NOV-00:00 | 17.10 | 14.63 |
| December | 0.144809E+10 | 2676.80 | 10-DEC-14:30 | 27.50 | 20.13 | 0.108512E+09 | 70.35 | 23-DEC-19:49 | 17.33 | 13.65 |
| Annual Sum or Average | 0.275398E+11 | 0.139937E+10 | ||||||||
| Minimum of Months | 0.111194E+10 | 2034.53 | 25.50 | 18.23 | 97575525.09 | 70.28 | 13.30 | 9.25 | ||
| Maximum of Months | 0.329163E+10 | 2972.06 | 36.07 | 27.34 | 0.129276E+09 | 70.37 | 36.07 | 26.98 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.111335E+10 | 2638.80 | 01-JAN-14:30 | 25.50 | 18.23 | 0.103046E+09 | 70.35 | 01-JAN-03:30 | 25.50 | 18.23 |
| February | 0.121448E+10 | 2296.48 | 27-FEB-14:40 | 25.90 | 20.26 | 97521595.08 | 70.35 | 22-FEB-02:49 | 25.90 | 20.26 |
| March | 0.131167E+10 | 2043.46 | 06-MAR-14:00 | 26.60 | 21.65 | 0.107137E+09 | 70.36 | 23-MAR-20:10 | 15.82 | 11.29 |
| April | 0.189583E+10 | 2216.34 | 28-APR-15:10 | 33.12 | 23.52 | 0.120353E+09 | 70.37 | 02-APR-20:49 | 33.12 | 23.52 |
| May | 0.304284E+10 | 2170.87 | 10-MAY-16:04 | 32.70 | 23.02 | 0.125733E+09 | 70.30 | 12-MAY-02:49 | 23.40 | 20.23 |
| June | 0.308878E+10 | 2228.94 | 10-JUN-16:30 | 33.35 | 21.77 | 0.120421E+09 | 70.30 | 11-JUN-02:49 | 23.40 | 20.23 |
| July | 0.326874E+10 | 2325.34 | 19-JUL-13:00 | 33.90 | 25.04 | 0.129276E+09 | 70.28 | 12-JUL-03:00 | 33.90 | 25.04 |
| August | 0.329277E+10 | 2442.60 | 30-AUG-16:03 | 36.07 | 23.60 | 0.123963E+09 | 70.30 | 20-AUG-06:40 | 36.07 | 23.60 |
| September | 0.301449E+10 | 2716.81 | 10-SEP-13:50 | 35.67 | 27.34 | 0.123963E+09 | 70.30 | 25-SEP-00:00 | 23.30 | 21.69 |
| October | 0.301195E+10 | 2976.22 | 09-OCT-14:00 | 31.00 | 23.79 | 0.125111E+09 | 70.34 | 29-OCT-23:40 | 17.33 | 14.85 |
| November | 0.185939E+10 | 2651.78 | 02-NOV-14:10 | 29.40 | 24.42 | 0.114139E+09 | 70.34 | 28-NOV-04:49 | 17.58 | 16.27 |
| December | 0.144704E+10 | 2679.05 | 10-DEC-14:30 | 27.50 | 20.13 | 0.108458E+09 | 70.35 | 02-DEC-22:49 | 27.50 | 20.13 |
| Annual Sum or Average | 0.275613E+11 | 0.139912E+10 | ||||||||
| Minimum of Months | 0.111335E+10 | 2043.46 | 25.50 | 18.23 | 97521595.08 | 70.28 | 15.82 | 11.29 | ||
| Maximum of Months | 0.329277E+10 | 2976.22 | 36.07 | 27.34 | 0.129276E+09 | 70.37 | 36.07 | 25.04 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 | 0.181652E+09 | 150.74 | 01-JAN-21:10 | 19.00 | 17.58 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.182056E+09 | 149.76 | 28-FEB-21:10 | 19.30 | 18.37 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 | 0.213509E+09 | 157.73 | 26-MAR-20:10 | 21.18 | 18.86 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.249599E+09 | 168.66 | 29-APR-20:10 | 26.00 | 22.58 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.11 | 0.291761E+09 | 176.68 | 25-MAY-20:10 | 29.63 | 24.18 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 | 0.286298E+09 | 178.98 | 28-JUN-20:10 | 29.22 | 24.17 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 | 0.297455E+09 | 180.39 | 22-JUL-20:10 | 28.12 | 24.42 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.55 | 0.295431E+09 | 178.84 | 24-AUG-20:10 | 31.58 | 24.53 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 | 0.278577E+09 | 181.42 | 09-SEP-20:10 | 34.67 | 27.13 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 | 0.275684E+09 | 176.17 | 05-OCT-20:10 | 27.00 | 24.12 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 | 0.222643E+09 | 161.55 | 02-NOV-20:10 | 24.92 | 23.29 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 | 0.197625E+09 | 155.53 | 15-DEC-21:10 | 23.00 | 22.28 |
| Annual Sum or Average | 0.00 | 0.297229E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.181652E+09 | 149.76 | 19.00 | 17.58 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.297455E+09 | 181.42 | 34.67 | 27.13 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 | 0.183666E+09 | 158.37 | 01-JAN-22:49 | 18.17 | 17.32 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.177039E+09 | 152.15 | 27-FEB-22:49 | 19.30 | 18.52 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 | 0.209100E+09 | 152.22 | 29-MAR-21:49 | 21.10 | 19.57 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.248966E+09 | 187.33 | 28-APR-17:10 | 29.80 | 24.19 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.11 | 0.308874E+09 | 209.91 | 07-MAY-17:10 | 33.22 | 23.18 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 | 0.307883E+09 | 210.88 | 13-JUN-17:10 | 33.03 | 21.90 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 | 0.323776E+09 | 230.60 | 22-JUL-17:10 | 34.63 | 26.60 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.55 | 0.323034E+09 | 228.08 | 30-AUG-17:10 | 34.67 | 23.11 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 | 0.302719E+09 | 238.95 | 09-SEP-17:10 | 36.18 | 26.62 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 | 0.299440E+09 | 208.98 | 05-OCT-17:10 | 32.83 | 23.08 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 | 0.240986E+09 | 167.57 | 02-NOV-21:49 | 24.17 | 23.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 | 0.211121E+09 | 163.14 | 16-DEC-22:49 | 22.00 | 22.00 |
| Annual Sum or Average | 0.00 | 0.313660E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.177039E+09 | 152.15 | 18.17 | 17.32 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.323776E+09 | 238.95 | 36.18 | 26.62 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 | 0.223581E+09 | 153.01 | 01-JAN-21:10 | 19.00 | 17.58 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.216770E+09 | 153.32 | 27-FEB-21:10 | 19.30 | 18.52 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 | 0.247017E+09 | 153.92 | 26-MAR-20:10 | 21.18 | 18.86 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.265203E+09 | 159.46 | 29-APR-20:10 | 26.00 | 22.58 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.11 | 0.285918E+09 | 161.93 | 03-MAY-20:10 | 28.30 | 22.17 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 | 0.278785E+09 | 163.46 | 28-JUN-20:10 | 29.22 | 24.17 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 | 0.288713E+09 | 163.87 | 22-JUL-20:10 | 28.12 | 24.42 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.55 | 0.287652E+09 | 162.90 | 30-AUG-20:10 | 29.63 | 22.50 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 | 0.275550E+09 | 164.77 | 10-SEP-20:10 | 28.45 | 24.95 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 | 0.281018E+09 | 161.55 | 05-OCT-20:10 | 27.00 | 24.12 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 | 0.256189E+09 | 157.10 | 02-NOV-20:10 | 24.92 | 23.29 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 | 0.238495E+09 | 154.12 | 16-DEC-21:10 | 22.08 | 21.69 |
| Annual Sum or Average | 0.00 | 0.314489E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.216770E+09 | 153.01 | 19.00 | 17.58 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.288713E+09 | 164.77 | 29.63 | 24.95 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 1809103.71 | 230.81 | 05-FEB-08:00 | -3.4 |
| March | 4588622.89 | 177.62 | 12-MAR-07:00 | 6.60 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 6397726.60 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 4588622.89 | 230.81 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 10552998.91 | 255.12 | 10-JAN-05:00 | 1.00 |
| February | 24934054.31 | 564.47 | 05-FEB-08:10 | -2.9 |
| March | 14341170.46 | 271.64 | 11-MAR-10:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 3101323.14 | 165.72 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 52929546.82 | |||
| Minimum of Months | 0.00 | 0.00 | -2.9 | |
| Maximum of Months | 24934054.31 | 564.47 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 79981500.78 | 387.59 | 16-JAN-15:00 | 27.00 |
| February | 0.105010E+09 | 397.20 | 25-FEB-17:00 | 27.20 |
| March | 0.186609E+09 | 503.08 | 26-MAR-14:00 | 30.00 |
| April | 0.310688E+09 | 676.25 | 28-APR-16:12 | 31.83 |
| May | 0.576797E+09 | 716.23 | 25-MAY-16:12 | 32.80 |
| June | 0.557906E+09 | 718.62 | 16-JUN-16:12 | 32.80 |
| July | 0.527264E+09 | 758.71 | 21-JUL-16:13 | 34.80 |
| August | 0.449425E+09 | 771.25 | 30-AUG-16:13 | 35.83 |
| September | 0.369104E+09 | 614.91 | 06-SEP-16:13 | 31.93 |
| October | 0.307895E+09 | 630.23 | 05-OCT-16:13 | 32.33 |
| November | 0.146519E+09 | 532.34 | 01-NOV-16:12 | 28.30 |
| December | 0.116665E+09 | 481.71 | 15-DEC-17:12 | 27.33 |
| Annual Sum or Average | 0.373386E+10 | |||
| Minimum of Months | 79981500.78 | 387.59 | 27.00 | |
| Maximum of Months | 0.576797E+09 | 771.25 | 35.83 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 9316929.22 | 257.24 | 10-JAN-04:00 | 2.00 |
| February | 20766949.53 | 479.44 | 05-FEB-07:20 | -3.4 |
| March | 12992959.26 | 265.78 | 11-MAR-10:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 4026681.45 | 195.40 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 47103519.45 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 20766949.53 | 479.44 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 324747.27 | 47.04 | 16-JAN-12:50 | 24.83 |
| February | 617276.97 | 61.74 | 20-FEB-15:00 | 25.00 |
| March | 693229.52 | 62.60 | 14-MAR-15:00 | 24.40 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 316930.08 | 28.77 | 27-DEC-14:00 | 24.00 |
| Annual Sum or Average | 1952183.85 | |||
| Minimum of Months | 0.00 | 0.00 | 20.72 | |
| Maximum of Months | 693229.52 | 62.60 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 328966.29 | 47.12 | 16-JAN-12:50 | 24.83 |
| February | 612971.05 | 61.72 | 20-FEB-15:00 | 25.00 |
| March | 683186.15 | 62.20 | 14-MAR-15:00 | 24.40 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 314986.43 | 28.71 | 27-DEC-14:00 | 24.00 |
| Annual Sum or Average | 1940109.91 | |||
| Minimum of Months | 0.00 | 0.00 | 20.72 | |
| Maximum of Months | 683186.15 | 62.20 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 9832526.45 | 586.72 | 05-FEB-07:20 | -3.4 |
| March | 4853955.60 | 186.60 | 11-MAR-10:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 2437601.67 | 185.07 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 17124083.72 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 9832526.45 | 586.72 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 36542299.50 | 429.50 | 10-JAN-04:00 | 2.00 |
| February | 38455204.03 | 861.24 | 05-FEB-08:00 | -3.4 |
| March | 11711106.86 | 325.40 | 11-MAR-10:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 31615494.59 | 472.72 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.118324E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 38455204.03 | 861.24 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 8544502.81 | 599.04 | 05-FEB-07:20 | -3.4 |
| March | 4580403.81 | 180.92 | 11-MAR-10:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 3341790.14 | 225.86 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 16466696.77 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 8544502.81 | 599.04 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 33243594.59 | 438.77 | 10-JAN-04:00 | 2.00 |
| February | 32399122.91 | 812.52 | 05-FEB-07:20 | -3.4 |
| March | 11104687.40 | 321.83 | 11-MAR-10:00 | 6.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 31657973.93 | 493.59 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.108405E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 33243594.59 | 812.52 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 76736.21 | 25.89 | 15-JAN-14:00 | 23.70 |
| February | 200955.90 | 49.37 | 05-FEB-08:08 | -2.9 |
| March | 330051.32 | 39.67 | 14-MAR-15:00 | 24.40 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 428573.31 | 29.91 | 27-DEC-14:00 | 24.00 |
| Annual Sum or Average | 1036316.74 | |||
| Minimum of Months | 0.00 | 0.00 | -2.9 | |
| Maximum of Months | 428573.31 | 49.37 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 76138.28 | 26.14 | 15-JAN-14:00 | 23.70 |
| February | 186799.54 | 47.68 | 05-FEB-08:08 | -2.9 |
| March | 320727.52 | 39.10 | 14-MAR-15:00 | 24.40 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 430906.23 | 29.78 | 27-DEC-14:00 | 24.00 |
| Annual Sum or Average | 1014571.57 | |||
| Minimum of Months | 0.00 | 0.00 | -2.9 | |
| Maximum of Months | 430906.23 | 47.68 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.373346E+09 | 1407.18 | 21-JAN-06:00 | 1.00 |
| February | 0.261400E+09 | 2296.96 | 05-FEB-07:20 | -3.4 |
| March | 0.219651E+09 | 1354.00 | 09-MAR-07:00 | 1.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 777287.25 | 93.81 | 28-OCT-06:00 | 10.00 |
| November | 17761646.80 | 396.64 | 16-NOV-06:00 | 9.40 |
| December | 0.275768E+09 | 1579.02 | 20-DEC-07:25 | 1.50 |
| Annual Sum or Average | 0.114870E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.373346E+09 | 2296.96 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.668833E+09 | 1566.62 | 05-JAN-05:00 | 1.00 |
| February | 0.419909E+09 | 2455.05 | 05-FEB-08:00 | -3.4 |
| March | 0.281051E+09 | 1514.22 | 09-MAR-07:00 | 1.10 |
| April | 184973.88 | 210.61 | 03-APR-08:07 | 16.55 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 4103731.06 | 292.41 | 28-OCT-08:00 | 10.00 |
| November | 60411318.12 | 616.20 | 16-NOV-05:00 | 9.20 |
| December | 0.460779E+09 | 1631.59 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.189527E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.668833E+09 | 2455.05 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.362010E+09 | 1429.89 | 21-JAN-06:00 | 1.00 |
| February | 0.251670E+09 | 2310.60 | 05-FEB-07:20 | -3.4 |
| March | 0.215456E+09 | 1374.95 | 09-MAR-06:50 | 1.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 711048.98 | 111.59 | 28-OCT-06:00 | 10.00 |
| November | 17256606.75 | 413.30 | 16-NOV-06:00 | 9.40 |
| December | 0.277380E+09 | 1583.43 | 20-DEC-07:25 | 1.50 |
| Annual Sum or Average | 0.112448E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.362010E+09 | 2310.60 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.639076E+09 | 1590.15 | 05-JAN-05:00 | 1.00 |
| February | 0.403928E+09 | 2412.81 | 05-FEB-07:20 | -3.4 |
| March | 0.272630E+09 | 1530.90 | 09-MAR-06:50 | 1.10 |
| April | 48211.30 | 227.46 | 03-APR-05:07 | 12.28 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 3226900.11 | 238.87 | 28-OCT-05:00 | 10.00 |
| November | 54645305.81 | 640.26 | 16-NOV-05:00 | 9.20 |
| December | 0.456060E+09 | 1656.84 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.182961E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.639076E+09 | 2412.81 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.313289E+09 | 999.64 | 05-JAN-05:00 | 1.00 |
| February | 0.201228E+09 | 1520.41 | 05-FEB-08:00 | -3.4 |
| March | 0.116647E+09 | 847.53 | 09-MAR-07:00 | 1.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 12557341.94 | 307.14 | 16-NOV-05:00 | 9.20 |
| December | 0.199997E+09 | 1025.35 | 21-DEC-06:00 | 1.00 |
| Annual Sum or Average | 0.843718E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.313289E+09 | 1520.41 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.313541E+09 | 1000.84 | 05-JAN-05:00 | 1.00 |
| February | 0.201430E+09 | 1518.81 | 05-FEB-08:00 | -3.4 |
| March | 0.116865E+09 | 847.82 | 09-MAR-07:00 | 1.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 12708661.23 | 309.13 | 16-NOV-05:00 | 9.20 |
| December | 0.201030E+09 | 1027.22 | 21-DEC-06:00 | 1.00 |
| Annual Sum or Average | 0.845576E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.313541E+09 | 1518.81 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.113348E+09 | 730.42 | 05-JAN-06:00 | 0.00 |
| February | 95023316.31 | 1375.64 | 05-FEB-07:00 | -3.4 |
| March | 78228984.74 | 674.12 | 09-MAR-07:00 | 1.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 369549.49 | 67.17 | 16-NOV-06:00 | 9.40 |
| December | 91610696.29 | 868.55 | 20-DEC-07:25 | 1.50 |
| Annual Sum or Average | 0.378580E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.113348E+09 | 1375.64 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.113833E+09 | 731.89 | 05-JAN-06:00 | 0.00 |
| February | 95249664.87 | 1376.21 | 05-FEB-07:00 | -3.4 |
| March | 78362697.74 | 675.44 | 09-MAR-07:00 | 1.10 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 390837.64 | 69.01 | 16-NOV-06:00 | 9.40 |
| December | 92094588.59 | 868.94 | 20-DEC-07:25 | 1.50 |
| Annual Sum or Average | 0.379931E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -3.4 | |
| Maximum of Months | 0.113833E+09 | 1376.21 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1800384.69 | 0.332487E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3752136.30 | 0.234508E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10602896.08 | 0.241922E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24174057.51 | 85126137.00 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 96772719.40 | 1623543.42 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91835194.09 | 2783504.07 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110035E+09 | 313611.11 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117747E+09 | 3472107.42 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87272746.11 | 6911264.70 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82747273.00 | 69603726.65 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10262158.70 | 0.146657E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6271056.25 | 0.279278E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.643273E+09 | 0.140469E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1800384.69 | 313611.11 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117747E+09 | 0.332487E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1812494.59 | 0.299020E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3788125.53 | 0.215169E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10700542.95 | 0.230737E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24174063.63 | 83741544.63 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 96772734.82 | 1623541.79 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91835207.02 | 2783505.47 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110035E+09 | 313611.22 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117747E+09 | 3472105.15 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87272751.95 | 6911255.52 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82747269.49 | 68877261.30 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10262160.30 | 0.142549E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6282560.31 | 0.257827E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.643430E+09 | 0.131302E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1812494.59 | 313611.22 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117747E+09 | 0.299020E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1137052.70 | 0.365245E+09 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3101734.55 | 0.255296E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6189390.70 | 0.284281E+09 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12671529.82 | 0.125430E+09 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 48846637.30 | 51709600.59 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 50614776.98 | 36659468.66 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47436916.17 | 32228258.67 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 62576654.85 | 58914790.59 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41217741.14 | 77046031.64 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41899507.78 | 0.160699E+09 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7604029.87 | 0.193534E+09 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3398258.75 | 0.324931E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326694E+09 | 0.196598E+10 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1137052.70 | 32228258.67 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 62576654.85 | 0.365245E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1807114.50 | 0.299125E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3800355.64 | 0.215468E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10680194.01 | 0.231492E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24174071.95 | 84172454.63 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 96772772.51 | 1623538.83 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91835234.67 | 2783500.37 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110035E+09 | 313611.11 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117747E+09 | 3472100.26 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87272786.17 | 6911244.26 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82747301.51 | 68948705.65 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10262165.05 | 0.143152E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6286954.50 | 0.257068E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.643421E+09 | 0.131453E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807114.50 | 313611.11 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117747E+09 | 0.299125E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1092679.65 | 0.184650E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2294673.77 | 0.133640E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6459177.12 | 0.144310E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14581191.52 | 51784395.45 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58370891.30 | 979274.43 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55392690.45 | 1678933.19 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66370431.21 | 189159.72 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021956.83 | 2094280.07 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52640737.68 | 4168678.23 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49911080.29 | 41883510.14 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6189879.87 | 87624959.42 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3790855.93 | 0.160247E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388116E+09 | 0.813250E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1092679.65 | 189159.72 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021956.83 | 0.184650E+09 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1092843.80 | 0.184665E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2294357.35 | 0.133678E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6457856.72 | 0.144365E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14581191.56 | 51796389.54 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58370891.62 | 979274.44 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55392690.67 | 1678933.09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66370431.54 | 189159.74 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021957.17 | 2094280.04 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52640737.97 | 4168678.13 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49911080.54 | 41883594.64 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6189879.91 | 87641040.99 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3790923.84 | 0.160170E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388115E+09 | 0.813309E+09 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1092843.80 | 189159.74 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021957.17 | 0.184665E+09 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1085948.61 | 0.208388E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2263196.67 | 0.147841E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6395406.39 | 0.151932E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14581188.01 | 52351182.33 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58370882.47 | 979275.76 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55392683.06 | 1678932.55 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66370421.27 | 189159.67 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021948.41 | 2094281.39 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52640734.32 | 4168684.14 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49911081.97 | 42111683.09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6189879.78 | 89017666.38 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3782545.22 | 0.174073E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388006E+09 | 0.874825E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1085948.61 | 189159.67 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021948.41 | 0.208388E+09 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1085948.61 | 0.208988E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2263196.63 | 0.148329E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6395405.99 | 0.152770E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14581187.56 | 52483526.75 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58370882.52 | 979282.87 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55392683.59 | 1678938.94 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66370423.74 | 189160.87 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021951.09 | 2094281.99 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52640737.02 | 4168687.14 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49911084.93 | 42121859.05 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6189879.70 | 89070011.15 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3782545.37 | 0.174676E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388006E+09 | 0.877549E+09 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1085948.61 | 189160.87 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71021951.09 | 0.208988E+09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2538566.62 | 0.475531E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5320141.70 | 0.344204E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15063876.35 | 0.356147E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34509576.56 | 0.124974E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138247E+09 | 2425913.40 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131371E+09 | 4090111.74 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157407E+09 | 470732.59 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 5098872.37 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124704E+09 | 10185236.45 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118238E+09 | 99488405.07 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14624308.58 | 0.209159E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8938586.69 | 0.395080E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919341E+09 | 0.202685E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2538566.62 | 470732.59 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 0.475531E+09 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2543237.33 | 0.429515E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5320144.95 | 0.319804E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15081019.31 | 0.344632E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34509584.67 | 0.124132E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138247E+09 | 2425909.80 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131371E+09 | 4090112.49 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157407E+09 | 470732.55 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 5098868.46 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124704E+09 | 10185220.98 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118238E+09 | 97213390.12 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14624312.43 | 0.200909E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8985443.64 | 0.364686E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919410E+09 | 0.190316E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2543237.33 | 470732.55 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 0.429515E+09 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2538571.18 | 0.477382E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5320148.30 | 0.344852E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15063893.01 | 0.357248E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34509595.90 | 0.125224E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138247E+09 | 2425905.38 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131371E+09 | 4090102.69 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157407E+09 | 470732.06 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 5098862.64 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124704E+09 | 10185214.04 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118239E+09 | 99532584.95 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14624320.08 | 0.209503E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8938593.27 | 0.395240E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919342E+09 | 0.203125E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2538571.18 | 470732.06 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 0.477382E+09 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2544963.18 | 0.429357E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5320150.05 | 0.320376E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15063907.17 | 0.346120E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34509600.65 | 0.124607E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138247E+09 | 2425902.91 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131371E+09 | 4090104.40 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157407E+09 | 470732.27 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 5098860.23 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124704E+09 | 10185202.14 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118239E+09 | 97408000.82 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14624320.43 | 0.202115E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8977945.71 | 0.363473E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919388E+09 | 0.190573E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2544963.18 | 470732.27 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168379E+09 | 0.429357E+09 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1532705.24 | 0.265979E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3208981.36 | 0.199657E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9106138.88 | 0.214803E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20815320.74 | 75820196.58 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83387239.50 | 1463233.89 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79239436.95 | 2467037.91 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94944079.45 | 283929.28 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 3075499.73 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 75218154.49 | 6143443.93 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71318473.75 | 59917758.15 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8821021.65 | 0.125165E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5403606.38 | 0.228408E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554557E+09 | 0.118318E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1532705.24 | 283929.28 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 0.265979E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1532775.94 | 0.265986E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3208981.38 | 0.199716E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9104276.08 | 0.214912E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20815320.81 | 75826665.34 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83387240.03 | 1463233.82 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79239437.32 | 2467037.76 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94944079.97 | 283929.31 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 3075499.67 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 75218154.91 | 6143443.77 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71318474.14 | 59919130.65 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8821021.69 | 0.125198E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5403524.18 | 0.228281E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554555E+09 | 0.118327E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1532775.94 | 283929.31 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 0.265986E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1531202.70 | 0.299853E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3208979.83 | 0.215655E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9086162.93 | 0.222247E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20815316.66 | 76090322.21 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83387227.30 | 1463235.59 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79239426.91 | 2467036.82 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94944066.39 | 283929.11 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 3075501.39 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 75218150.41 | 6143452.17 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71318476.16 | 60682181.40 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8821021.02 | 0.127894E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5391534.04 | 0.248088E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554524E+09 | 0.126394E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1531202.70 | 283929.11 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 0.299853E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1531202.73 | 0.299886E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3208979.88 | 0.215664E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9086163.09 | 0.222297E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20815316.77 | 76091169.05 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83387227.83 | 1463235.51 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79239427.28 | 2467036.66 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94944066.91 | 283929.14 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 3075501.34 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 75218150.87 | 6143452.01 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 71318476.66 | 60680188.46 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8821021.12 | 0.127895E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5391534.10 | 0.248057E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554524E+09 | 0.126400E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1531202.73 | 283929.14 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101562E+09 | 0.299886E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3229094.15 | 0.590740E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6848874.87 | 0.423492E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19474272.02 | 0.434931E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45043378.70 | 0.153093E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180698E+09 | 3455626.65 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172180E+09 | 5649333.70 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206309E+09 | 676285.85 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 7035508.25 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163073E+09 | 14147395.31 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154620E+09 | 0.119741E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19020630.02 | 0.250001E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11629716.06 | 0.483724E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120266E+10 | 0.248669E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3229094.15 | 676285.85 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 0.590740E+09 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3229095.26 | 0.552915E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6848876.11 | 0.401180E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19474296.10 | 0.419833E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45043383.75 | 0.150356E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180698E+09 | 3455623.14 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172180E+09 | 5649337.61 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206309E+09 | 676286.08 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 7035505.25 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163073E+09 | 14147378.91 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154620E+09 | 0.113945E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19038858.96 | 0.231912E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11665312.06 | 0.456954E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120271E+10 | 0.235806E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3229095.26 | 676286.08 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 0.552915E+09 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3229103.31 | 0.592765E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6848887.93 | 0.424630E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19474304.07 | 0.437597E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45043417.32 | 0.154628E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180698E+09 | 3455612.74 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172180E+09 | 5649320.91 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206309E+09 | 676284.37 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 7035491.20 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163073E+09 | 14147357.09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154620E+09 | 0.120266E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19020652.21 | 0.251822E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11629729.34 | 0.484571E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120266E+10 | 0.249724E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3229103.31 | 676284.37 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 0.592765E+09 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3229102.21 | 0.551569E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6848886.34 | 0.401318E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19474320.02 | 0.421940E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45043420.14 | 0.152096E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180698E+09 | 3455609.11 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172180E+09 | 5649324.41 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206309E+09 | 676284.53 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 7035488.25 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163073E+09 | 14147340.95 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154620E+09 | 0.113741E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19020648.76 | 0.233171E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11629728.98 | 0.455274E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120266E+10 | 0.236007E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3229102.21 | 676284.53 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220532E+09 | 0.551569E+09 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.82 | 0.335319E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4131074.85 | 0.244728E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11746419.92 | 0.258074E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27169045.93 | 93871022.65 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108992E+09 | 2084334.18 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103855E+09 | 3407524.66 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124440E+09 | 407912.64 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 4243628.46 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98361665.98 | 8533314.71 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93263093.59 | 70924423.11 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11474306.78 | 0.144053E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7026383.01 | 0.277980E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.725426E+09 | 0.144363E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.82 | 407912.64 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 0.335319E+09 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.87 | 0.335303E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4131074.93 | 0.244759E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11746419.85 | 0.258212E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27169046.45 | 93909741.01 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108992E+09 | 2084333.85 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103855E+09 | 3407524.29 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124440E+09 | 407912.67 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 4243628.22 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98361667.77 | 8533314.19 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93263095.21 | 70874466.06 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11473659.29 | 0.144093E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7024320.88 | 0.277870E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.725424E+09 | 0.144370E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.87 | 407912.67 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 0.335303E+09 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.66 | 0.365020E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4131074.56 | 0.262618E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11746406.55 | 0.269616E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27169042.13 | 95623689.40 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108992E+09 | 2084336.49 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103855E+09 | 3407522.31 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124440E+09 | 407912.46 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 4243630.47 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98361666.69 | 8533325.23 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93263109.28 | 75220729.91 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11472772.69 | 0.156884E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7014756.73 | 0.298977E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.725413E+09 | 0.154264E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.66 | 407912.46 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 0.365020E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.79 | 0.365079E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4131074.76 | 0.262640E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11746407.21 | 0.269717E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27169042.66 | 95640017.85 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108992E+09 | 2084336.17 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103855E+09 | 3407521.95 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124440E+09 | 407912.50 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 4243630.26 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98361668.52 | 8533324.72 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93263111.16 | 75210512.05 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11472773.04 | 0.156895E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7014756.94 | 0.298956E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.725413E+09 | 0.154281E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1947712.79 | 407912.50 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133019E+09 | 0.365079E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46472.02 | 0.105928E+09 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 273134.62 | 77505468.69 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 761783.94 | 85499371.79 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2834265.56 | 36030558.05 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13278234.05 | 6878421.63 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14040796.97 | 4814819.48 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16690883.74 | 2458347.39 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17995395.02 | 7166702.52 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12444450.36 | 11521325.16 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10797496.92 | 32413063.10 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1189770.82 | 50891800.32 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 647278.04 | 89089813.32 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90999962.05 | 0.510198E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46472.02 | 2458347.39 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17995395.02 | 0.105928E+09 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1330498.85 | 0.208368E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4634065.02 | 0.153529E+10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18466607.41 | 0.142150E+10 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 84132135.00 | 0.795109E+09 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339942E+09 | 0.149827E+09 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.408479E+09 | 98313163.45 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.390528E+09 | 89748666.06 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.375740E+09 | 0.163226E+09 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207755E+09 | 0.246943E+09 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168766E+09 | 0.535236E+09 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22710887.66 | 0.126891E+10 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12764976.63 | 0.180109E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203525E+10 | 0.101889E+11 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1330498.85 | 89748666.06 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.408479E+09 | 0.208368E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33247.28 | 91676882.02 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181141.80 | 68033289.84 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 628893.22 | 75161492.52 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2582153.29 | 30410040.18 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11768825.10 | 4834163.66 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12549794.78 | 3529803.21 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14835930.75 | 1695204.92 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15823598.45 | 5056966.08 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10932539.78 | 8555814.52 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9808914.60 | 27639838.25 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 936533.11 | 45511055.99 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 551079.10 | 78831210.14 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80632651.25 | 0.440936E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33247.28 | 1695204.92 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15823598.45 | 91676882.02 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 19-JAN-12:10 | 446.79 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.47 | 02-FEB-13:00 | 583.32 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.26 | 28-MAR-14:00 | 432.95 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.93 | 29-APR-16:00 | 260.19 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.84 | 25-MAY-14:00 | 21.56 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 223.49 | 08-JUN-15:00 | 48.06 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 19-JUL-13:00 | 20.99 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 233.74 | 20-AUG-14:00 | 79.55 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.48 | 09-SEP-23:00 | 57.32 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 302.24 | 09-OCT-14:00 | 231.37 | 28-OCT-08:40 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.18 | 07-NOV-13:00 | 310.27 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.89 | 13-DEC-14:00 | 468.30 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 20.99 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 583.32 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 19-JAN-12:10 | 388.83 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.47 | 02-FEB-13:00 | 545.01 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.26 | 28-MAR-14:00 | 409.18 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.93 | 29-APR-16:00 | 254.60 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.84 | 25-MAY-14:00 | 21.56 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 223.49 | 08-JUN-15:00 | 48.06 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 19-JUL-13:00 | 20.99 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 233.74 | 20-AUG-14:00 | 79.55 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.48 | 09-SEP-23:00 | 57.32 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 302.24 | 09-OCT-14:00 | 230.80 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.18 | 07-NOV-13:00 | 301.21 | 12-NOV-07:10 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.89 | 13-DEC-14:00 | 443.95 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 20.99 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 545.01 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 19-JAN-12:10 | 474.77 | 09-JAN-17:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 108.47 | 02-FEB-13:00 | 617.85 | 16-FEB-18:01 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 107.26 | 28-MAR-14:00 | 459.15 | 20-MAR-19:00 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.83 | 28-APR-15:00 | 289.85 | 01-APR-21:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.84 | 25-MAY-14:00 | 112.74 | 14-MAY-12:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 223.49 | 08-JUN-15:00 | 151.92 | 06-JUN-21:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 385.22 | 19-JUL-13:00 | 120.54 | 30-JUL-11:00 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 215.63 | 03-AUG-16:00 | 156.10 | 16-AUG-04:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.78 | 13-SEP-13:00 | 183.54 | 12-SEP-20:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.61 | 10-OCT-15:00 | 273.42 | 27-OCT-07:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.14 | 07-NOV-13:00 | 343.81 | 12-NOV-08:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 78.89 | 13-DEC-14:00 | 501.90 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 112.74 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 385.22 | 617.85 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 19-JAN-12:10 | 388.83 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.47 | 02-FEB-13:00 | 545.01 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.26 | 28-MAR-14:00 | 408.84 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.93 | 29-APR-16:00 | 255.30 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.84 | 25-MAY-14:00 | 21.56 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 223.49 | 08-JUN-15:00 | 48.06 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 19-JUL-13:00 | 20.99 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 233.74 | 20-AUG-14:00 | 79.55 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.48 | 09-SEP-23:00 | 57.32 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 302.24 | 09-OCT-14:00 | 230.84 | 27-OCT-07:30 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.18 | 07-NOV-13:00 | 303.57 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.89 | 13-DEC-14:00 | 443.42 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.81 | 20.99 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 545.01 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 19-JAN-12:10 | 237.40 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.43 | 02-FEB-13:00 | 331.17 | 16-FEB-18:25 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.70 | 28-MAR-14:00 | 259.60 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.12 | 29-APR-16:00 | 157.41 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.16 | 25-MAY-14:00 | 13.00 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 134.81 | 08-JUN-15:00 | 28.99 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 19-JUL-13:00 | 12.66 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.99 | 20-AUG-14:00 | 47.98 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.94 | 09-SEP-23:00 | 34.58 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 09-OCT-14:00 | 139.18 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.77 | 07-NOV-13:00 | 186.31 | 12-NOV-07:10 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.59 | 13-DEC-14:00 | 285.75 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 12.66 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 331.17 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 19-JAN-12:10 | 237.41 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.43 | 02-FEB-13:00 | 331.19 | 16-FEB-18:25 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.70 | 28-MAR-14:00 | 259.75 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.12 | 29-APR-16:00 | 157.41 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.16 | 25-MAY-14:00 | 13.00 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 134.81 | 08-JUN-15:00 | 28.99 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 19-JUL-13:00 | 12.66 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.99 | 20-AUG-14:00 | 47.98 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.94 | 09-SEP-23:00 | 34.58 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 09-OCT-14:00 | 139.18 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.77 | 07-NOV-13:00 | 186.31 | 12-NOV-07:10 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.59 | 13-DEC-14:00 | 285.72 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 12.66 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 331.19 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 19-JAN-12:10 | 280.76 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.43 | 02-FEB-13:00 | 373.06 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.70 | 28-MAR-14:00 | 274.68 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.12 | 29-APR-16:00 | 157.41 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.16 | 25-MAY-14:00 | 13.00 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 134.81 | 08-JUN-15:00 | 28.99 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 19-JUL-13:00 | 12.66 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.99 | 20-AUG-14:00 | 47.98 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.94 | 09-SEP-23:00 | 34.58 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 09-OCT-14:00 | 143.10 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.77 | 07-NOV-13:00 | 192.34 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.59 | 13-DEC-14:00 | 301.39 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 12.66 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 373.06 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 19-JAN-12:10 | 282.12 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.43 | 02-FEB-13:00 | 375.85 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.70 | 28-MAR-14:00 | 276.81 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.12 | 29-APR-16:00 | 157.41 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.16 | 25-MAY-14:00 | 13.00 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 134.81 | 08-JUN-15:00 | 28.99 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 19-JUL-13:00 | 12.66 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.99 | 20-AUG-14:00 | 47.98 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.94 | 09-SEP-23:00 | 34.58 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 09-OCT-14:00 | 143.10 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.77 | 07-NOV-13:00 | 192.71 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.59 | 13-DEC-14:00 | 303.63 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 24.02 | 12.66 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 232.38 | 375.85 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 19-JAN-12:10 | 644.92 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.17 | 02-FEB-13:00 | 871.93 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.19 | 28-MAR-14:00 | 642.56 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 252.00 | 29-APR-16:00 | 375.91 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.14 | 25-MAY-14:00 | 31.49 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 320.40 | 08-JUN-15:00 | 69.46 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 19-JUL-13:00 | 31.03 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 335.24 | 20-AUG-14:00 | 114.91 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.71 | 09-SEP-23:00 | 83.06 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 433.12 | 09-OCT-14:00 | 326.11 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.41 | 07-NOV-13:00 | 435.10 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.93 | 13-DEC-14:00 | 637.58 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 31.03 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 871.93 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 19-JAN-12:10 | 559.62 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.17 | 02-FEB-13:00 | 785.98 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.19 | 28-MAR-14:00 | 613.91 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 252.00 | 29-APR-16:00 | 375.91 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.14 | 25-MAY-14:00 | 31.49 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 320.40 | 08-JUN-15:00 | 69.46 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 19-JUL-13:00 | 31.03 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 335.24 | 20-AUG-14:00 | 114.91 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.71 | 09-SEP-23:00 | 83.06 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 433.12 | 09-OCT-14:00 | 319.97 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.41 | 07-NOV-13:00 | 421.96 | 12-NOV-07:10 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.93 | 13-DEC-14:00 | 637.49 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 31.03 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 785.98 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 19-JAN-12:10 | 634.76 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.17 | 02-FEB-13:00 | 857.81 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.19 | 28-MAR-14:00 | 637.50 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 252.00 | 29-APR-16:00 | 375.91 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.14 | 25-MAY-14:00 | 31.49 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 320.40 | 08-JUN-15:00 | 69.46 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 19-JUL-13:00 | 31.03 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 335.24 | 20-AUG-14:00 | 114.91 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.71 | 09-SEP-23:00 | 83.06 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 433.12 | 09-OCT-14:00 | 330.51 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.41 | 07-NOV-13:00 | 443.12 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.93 | 13-DEC-14:00 | 637.58 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 31.03 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 857.81 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 19-JAN-12:10 | 559.62 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.17 | 02-FEB-13:00 | 783.86 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.19 | 28-MAR-14:00 | 609.98 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 252.00 | 29-APR-16:00 | 375.91 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 295.14 | 25-MAY-14:00 | 31.49 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 320.40 | 08-JUN-15:00 | 69.46 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 19-JUL-13:00 | 31.03 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 335.24 | 20-AUG-14:00 | 114.91 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 294.71 | 09-SEP-23:00 | 83.06 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 433.12 | 09-OCT-14:00 | 322.91 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.41 | 07-NOV-13:00 | 428.64 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.93 | 13-DEC-14:00 | 637.49 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.60 | 31.03 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 783.86 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 19-JAN-12:10 | 340.82 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.59 | 02-FEB-13:00 | 502.24 | 16-FEB-18:25 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.40 | 28-MAR-14:00 | 388.29 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.00 | 29-APR-16:00 | 226.74 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.02 | 25-MAY-14:00 | 18.99 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.26 | 08-JUN-15:00 | 41.90 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 19-JUL-13:00 | 18.72 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.21 | 20-AUG-14:00 | 69.31 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.76 | 09-SEP-23:00 | 50.10 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 09-OCT-14:00 | 200.45 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.63 | 07-NOV-13:00 | 264.16 | 12-NOV-07:10 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.12 | 13-DEC-14:00 | 394.68 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 502.24 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 19-JAN-12:10 | 340.82 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.59 | 02-FEB-13:00 | 502.20 | 16-FEB-18:25 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.40 | 28-MAR-14:00 | 388.56 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.00 | 29-APR-16:00 | 226.74 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.02 | 25-MAY-14:00 | 18.99 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.26 | 08-JUN-15:00 | 41.90 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 19-JUL-13:00 | 18.72 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.21 | 20-AUG-14:00 | 69.31 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.76 | 09-SEP-23:00 | 50.10 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 09-OCT-14:00 | 200.45 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.63 | 07-NOV-13:00 | 264.16 | 12-NOV-07:10 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.12 | 13-DEC-14:00 | 394.66 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 502.20 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 19-JAN-12:10 | 407.30 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.59 | 02-FEB-13:00 | 550.76 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.40 | 28-MAR-14:00 | 403.26 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.00 | 29-APR-16:00 | 226.74 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.02 | 25-MAY-14:00 | 18.99 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.26 | 08-JUN-15:00 | 41.90 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 19-JUL-13:00 | 18.72 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.21 | 20-AUG-14:00 | 69.31 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.76 | 09-SEP-23:00 | 50.10 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 09-OCT-14:00 | 204.10 | 28-OCT-08:40 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.63 | 07-NOV-13:00 | 272.73 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.12 | 13-DEC-14:00 | 418.16 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 550.76 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 19-JAN-12:10 | 407.40 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 93.59 | 02-FEB-13:00 | 550.59 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.40 | 28-MAR-14:00 | 403.29 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.00 | 29-APR-16:00 | 226.74 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.02 | 25-MAY-14:00 | 18.99 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.26 | 08-JUN-15:00 | 41.90 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 19-JUL-13:00 | 18.72 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 202.21 | 20-AUG-14:00 | 69.31 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 177.76 | 09-SEP-23:00 | 50.10 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 09-OCT-14:00 | 204.16 | 28-OCT-08:40 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.63 | 07-NOV-13:00 | 272.79 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.12 | 13-DEC-14:00 | 418.18 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.14 | 18.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 333.28 | 550.59 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 19-JAN-12:10 | 828.35 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 203.35 | 02-FEB-13:00 | 1038.58 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 200.11 | 28-MAR-14:00 | 779.86 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.13 | 29-APR-16:00 | 471.49 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.64 | 25-MAY-14:00 | 43.01 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 421.77 | 08-JUN-15:00 | 92.95 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 19-JUL-13:00 | 43.31 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 441.69 | 20-AUG-14:00 | 153.58 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.31 | 09-SEP-23:00 | 111.67 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 569.67 | 09-OCT-14:00 | 358.16 | 28-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 157.81 | 07-NOV-13:00 | 504.65 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.19 | 13-DEC-14:00 | 845.82 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 43.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 1038.58 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 19-JAN-12:10 | 742.51 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 203.35 | 02-FEB-13:00 | 1038.58 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 200.11 | 28-MAR-14:00 | 779.86 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.13 | 29-APR-16:00 | 456.12 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.64 | 25-MAY-14:00 | 43.01 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 421.77 | 08-JUN-15:00 | 92.95 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 19-JUL-13:00 | 43.31 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 441.69 | 20-AUG-14:00 | 153.58 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.31 | 09-SEP-23:00 | 111.67 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 569.67 | 09-OCT-14:00 | 358.16 | 28-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 157.81 | 07-NOV-13:00 | 504.65 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.19 | 13-DEC-14:00 | 845.82 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 43.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 1038.58 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 19-JAN-12:10 | 797.43 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 203.35 | 02-FEB-13:00 | 1038.58 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 200.11 | 28-MAR-14:00 | 779.86 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.13 | 29-APR-16:00 | 467.16 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.64 | 25-MAY-14:00 | 43.01 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 421.77 | 08-JUN-15:00 | 92.95 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 19-JUL-13:00 | 43.31 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 441.69 | 20-AUG-14:00 | 153.58 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.31 | 09-SEP-23:00 | 111.67 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 569.67 | 09-OCT-14:00 | 358.17 | 27-OCT-08:40 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 157.81 | 07-NOV-13:00 | 504.65 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.19 | 13-DEC-14:00 | 845.82 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 43.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 1038.58 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 19-JAN-12:10 | 742.51 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 203.35 | 02-FEB-13:00 | 1038.58 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 200.11 | 28-MAR-14:00 | 779.86 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 331.13 | 29-APR-16:00 | 450.85 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.64 | 25-MAY-14:00 | 43.01 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 421.77 | 08-JUN-15:00 | 92.95 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 19-JUL-13:00 | 43.31 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 441.69 | 20-AUG-14:00 | 153.58 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 388.31 | 09-SEP-23:00 | 111.67 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 569.67 | 09-OCT-14:00 | 358.16 | 28-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 157.81 | 07-NOV-13:00 | 504.65 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.19 | 13-DEC-14:00 | 845.82 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 73.23 | 43.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 1038.58 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 19-JAN-12:10 | 447.86 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 122.66 | 02-FEB-13:00 | 626.44 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.70 | 28-MAR-14:00 | 470.39 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.73 | 29-APR-16:00 | 294.13 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.42 | 25-MAY-14:00 | 25.94 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.40 | 08-JUN-15:00 | 56.07 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 19-JUL-13:00 | 26.12 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 266.41 | 20-AUG-14:00 | 92.64 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.22 | 09-SEP-23:00 | 67.36 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 09-OCT-14:00 | 227.52 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.18 | 07-NOV-13:00 | 304.62 | 12-NOV-07:01 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.39 | 13-DEC-14:00 | 510.18 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 25.94 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 626.44 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 19-JAN-12:10 | 447.86 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 122.66 | 02-FEB-13:00 | 626.44 | 05-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.70 | 28-MAR-14:00 | 470.39 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.73 | 29-APR-16:00 | 293.82 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.42 | 25-MAY-14:00 | 25.94 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.40 | 08-JUN-15:00 | 56.07 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 19-JUL-13:00 | 26.12 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 266.41 | 20-AUG-14:00 | 92.64 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.22 | 09-SEP-23:00 | 67.36 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 09-OCT-14:00 | 227.36 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.18 | 07-NOV-13:00 | 304.57 | 12-NOV-07:01 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.39 | 13-DEC-14:00 | 510.18 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 25.94 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 626.44 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 19-JAN-12:10 | 515.49 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 122.66 | 02-FEB-13:00 | 660.97 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.70 | 28-MAR-14:00 | 470.39 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.73 | 29-APR-16:00 | 301.29 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.42 | 25-MAY-14:00 | 25.94 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.40 | 08-JUN-15:00 | 56.07 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 19-JUL-13:00 | 26.12 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 266.41 | 20-AUG-14:00 | 92.64 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.22 | 09-SEP-23:00 | 67.36 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 09-OCT-14:00 | 232.63 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.19 | 07-NOV-13:00 | 312.77 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.39 | 13-DEC-14:00 | 510.18 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 25.94 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 660.97 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 19-JAN-12:10 | 515.43 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 122.66 | 02-FEB-13:00 | 660.40 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.70 | 28-MAR-14:00 | 470.39 | 09-MAR-09:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.73 | 29-APR-16:00 | 301.22 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.42 | 25-MAY-14:00 | 25.94 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.40 | 08-JUN-15:00 | 56.07 | 07-JUN-02:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 19-JUL-13:00 | 26.12 | 31-JUL-11:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 266.41 | 20-AUG-14:00 | 92.64 | 25-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.22 | 09-SEP-23:00 | 67.36 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 09-OCT-14:00 | 232.48 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.19 | 07-NOV-13:00 | 312.88 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.39 | 13-DEC-14:00 | 510.18 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 44.17 | 25.94 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 660.40 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.81 | 16-JAN-15:00 | 141.96 | 09-JAN-17:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.97 | 02-FEB-13:00 | 193.54 | 16-FEB-18:12 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.31 | 27-MAR-15:00 | 142.53 | 20-MAR-19:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.00 | 28-APR-15:00 | 95.36 | 01-APR-21:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.11 | 25-MAY-14:00 | 24.43 | 19-MAY-19:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.24 | 08-JUN-15:00 | 36.36 | 06-JUN-21:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.85 | 19-JUL-13:00 | 29.18 | 31-JUL-11:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.62 | 20-AUG-14:00 | 38.36 | 25-AUG-24:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.05 | 09-SEP-17:00 | 39.45 | 19-SEP-19:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.43 | 09-OCT-14:00 | 73.45 | 27-OCT-07:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.94 | 28-NOV-13:00 | 98.96 | 12-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.45 | 13-DEC-14:00 | 143.27 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.81 | 24.43 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.85 | 193.54 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 176.13 | 16-JAN-15:00 | 12919.43 | 21-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.04 | 02-FEB-13:00 | 15015.35 | 05-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 636.08 | 27-MAR-16:03 | 12766.48 | 09-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2524.48 | 28-APR-16:02 | 8503.72 | 11-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2996.42 | 28-MAY-16:02 | 2044.35 | 02-MAY-06:03 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3124.43 | 10-JUN-16:02 | 2325.62 | 07-JUN-06:03 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4111.85 | 22-JUL-16:01 | 1358.05 | 12-JUL-16:03 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4256.29 | 30-AUG-16:01 | 2455.51 | 29-AUG-06:02 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4131.29 | 09-SEP-16:01 | 2854.68 | 07-SEP-16:02 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2343.95 | 05-OCT-16:02 | 8358.09 | 28-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 846.12 | 01-NOV-16:02 | 10167.90 | 12-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 469.95 | 15-DEC-17:02 | 12604.14 | 18-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 176.13 | 1358.05 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 4256.29 | 15015.35 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 16-JAN-15:00 | 115.64 | 09-JAN-17:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.65 | 02-FEB-13:00 | 165.09 | 16-FEB-18:12 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.13 | 27-MAR-15:00 | 126.28 | 20-MAR-19:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.33 | 28-APR-15:00 | 76.98 | 01-APR-21:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.15 | 25-MAY-14:00 | 16.11 | 05-MAY-06:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.62 | 08-JUN-15:00 | 26.19 | 06-JUN-21:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.23 | 19-JUL-13:00 | 20.64 | 31-JUL-11:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.87 | 20-AUG-14:00 | 30.10 | 25-AUG-24:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.84 | 09-SEP-17:00 | 27.45 | 19-SEP-19:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.15 | 09-OCT-14:00 | 66.00 | 27-OCT-07:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.38 | 28-NOV-13:00 | 85.46 | 12-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.52 | 13-DEC-14:20 | 130.51 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 16.11 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.23 | 165.09 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1968.31 | 01-JAN-16:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 4.60 | 0.00 |
| February | 1722.04 | 27-FEB-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 19.95 | 0.00 |
| March | 1445.03 | 06-MAR-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 51.88 | 0.00 |
| April | 1726.29 | 29-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 164.26 | 0.00 |
| May | 1778.61 | 10-MAY-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 124.07 | 0.00 |
| June | 1885.28 | 10-JUN-17:05 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 186.41 | 0.00 |
| July | 1977.41 | 22-JUL-16:40 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 49.86 | 0.00 |
| August | 2273.83 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 99.98 | 0.00 |
| September | 2411.72 | 10-SEP-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 84.43 | 0.00 |
| October | 2493.26 | 08-OCT-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 210.97 | 0.00 |
| November | 2113.96 | 06-NOV-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 19.32 | 0.00 |
| December | 2066.69 | 10-DEC-16:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 30.20 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1445.03 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 4.60 | 0.00 | |
| Maximum of Months | 2493.26 | 1187.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 210.97 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1049.46 | 01-JAN-17:03 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.09 |
| February | 1053.65 | 27-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 | 0.00 |
| March | 1003.26 | 29-MAR-16:14 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 47.84 | 0.00 |
| April | 1535.96 | 29-APR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 152.98 | 0.00 |
| May | 1764.56 | 29-MAY-17:10 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 91.76 | 0.00 |
| June | 1939.61 | 28-JUN-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 139.94 | 0.00 |
| July | 2011.00 | 07-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 112.39 | 0.00 |
| August | 2191.51 | 03-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 224.89 | 0.00 |
| September | 2133.86 | 09-SEP-17:02 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 200.54 | 0.00 |
| October | 1977.01 | 08-OCT-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 210.97 | 0.00 |
| November | 1497.25 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 50.19 | 0.00 |
| December | 1291.36 | 15-DEC-17:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 15.34 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1003.26 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2191.51 | 1033.12 | 585.91 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 224.89 | 3.09 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6161.69 | 03-JAN-09:02 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 405.34 |
| February | 5672.18 | 10-FEB-09:02 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 5806.99 | 01-MAR-09:02 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 173.24 |
| April | 6364.23 | 17-APR-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.79 |
| May | 5035.29 | 12-MAY-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 |
| June | 5118.66 | 07-JUN-07:02 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.45 |
| July | 4478.17 | 10-JUL-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 3.78 | 0.00 |
| August | 4549.84 | 28-AUG-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 28.57 | 0.00 |
| September | 5007.14 | 22-SEP-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.49 |
| October | 6898.78 | 17-OCT-07:02 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.39 |
| November | 6638.50 | 14-NOV-09:02 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.68 |
| December | 6591.20 | 01-DEC-09:02 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 200.59 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4478.17 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6898.78 | 2707.23 | 3497.50 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 28.57 | 405.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 869.11 | 01-JAN-17:03 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.09 |
| February | 765.82 | 27-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 | 0.00 |
| March | 960.78 | 30-MAR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 26.90 | 0.00 |
| April | 1304.68 | 29-APR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 164.26 | 0.00 |
| May | 1543.18 | 18-MAY-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 186.55 | 0.00 |
| June | 1689.09 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 158.44 | 0.00 |
| July | 1928.44 | 19-JUL-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 0.00 |
| August | 1961.78 | 03-AUG-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 224.89 | 0.00 |
| September | 1879.41 | 10-SEP-10:30 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 123.11 | 0.00 |
| October | 1758.15 | 08-OCT-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 210.97 | 0.00 |
| November | 1286.92 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 50.19 | 0.00 |
| December | 1073.75 | 16-DEC-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 70.78 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 765.82 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1961.78 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 385.27 | 3.09 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 810.27 | 02-JAN-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 3.11 | 0.00 |
| February | 724.46 | 28-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.12 |
| March | 832.12 | 30-MAR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 16.23 | 0.00 |
| April | 1063.70 | 29-APR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 99.08 | 0.00 |
| May | 1262.89 | 25-MAY-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 72.21 | 0.00 |
| June | 1394.16 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.57 | 0.00 |
| July | 1474.43 | 19-JUL-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 104.00 | 0.00 |
| August | 1539.68 | 03-AUG-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 133.54 | 0.00 |
| September | 1488.37 | 09-SEP-17:15 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 118.89 | 0.00 |
| October | 1401.23 | 08-OCT-16:03 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 127.25 | 0.00 |
| November | 1071.30 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 30.27 | 0.00 |
| December | 943.35 | 15-DEC-17:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 9.25 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 724.46 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1539.68 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 133.54 | 6.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 808.57 | 02-JAN-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 3.11 | 0.00 |
| February | 720.00 | 28-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.12 |
| March | 835.99 | 30-MAR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 16.23 | 0.00 |
| April | 1061.45 | 29-APR-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 99.08 | 0.00 |
| May | 1260.84 | 25-MAY-17:20 | 619.87 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 72.21 | 0.00 |
| June | 1390.85 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 95.57 | 0.00 |
| July | 1474.66 | 19-JUL-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 104.00 | 0.00 |
| August | 1536.87 | 03-AUG-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 133.54 | 0.00 |
| September | 1483.86 | 09-SEP-17:15 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 118.89 | 0.00 |
| October | 1397.75 | 08-OCT-16:03 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 127.25 | 0.00 |
| November | 1068.76 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 30.27 | 0.00 |
| December | 936.40 | 15-DEC-17:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 9.25 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 720.00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1536.87 | 826.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 133.54 | 6.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1740.85 | 01-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 0.00 |
| February | 1396.92 | 27-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 12.89 | 0.00 |
| March | 1155.93 | 06-MAR-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 39.88 | 0.00 |
| April | 1253.94 | 29-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 99.08 | 0.00 |
| May | 1278.37 | 07-MAY-17:17 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 64.65 | 0.00 |
| June | 1346.05 | 10-JUN-17:05 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 112.44 | 0.00 |
| July | 1458.05 | 23-JUL-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.82 | 0.00 |
| August | 1623.01 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 60.31 | 0.00 |
| September | 1768.55 | 10-SEP-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 50.93 | 0.00 |
| October | 1982.58 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 0.00 |
| November | 1711.53 | 06-NOV-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 12.47 | 0.00 |
| December | 1756.01 | 16-DEC-13:30 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 37.42 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1155.93 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 0.00 | |
| Maximum of Months | 1982.58 | 1187.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1895.06 | 01-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 0.00 |
| February | 1457.45 | 27-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 12.89 | 0.00 |
| March | 1213.63 | 06-MAR-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 39.88 | 0.00 |
| April | 1357.21 | 29-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 99.08 | 0.00 |
| May | 1415.69 | 07-MAY-17:20 | 712.50 | 351.55 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 64.65 | 0.00 |
| June | 1462.17 | 10-JUN-17:10 | 950.00 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 112.44 | 0.00 |
| July | 1614.15 | 23-JUL-16:03 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 80.82 | 0.00 |
| August | 1712.14 | 27-AUG-16:20 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 103.37 | 0.00 |
| September | 1926.91 | 10-SEP-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 50.93 | 0.00 |
| October | 2160.00 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 0.00 |
| November | 1810.21 | 06-NOV-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11.64 | 0.00 |
| December | 1867.96 | 10-DEC-14:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 23.24 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1213.63 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 0.00 | |
| Maximum of Months | 2160.00 | 1187.50 | 468.73 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 182.31 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2293.81 | 01-JAN-15:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 10.42 | 0.00 |
| February | 2201.75 | 27-FEB-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 28.24 | 0.00 |
| March | 2001.63 | 06-MAR-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 73.79 | 0.00 |
| April | 2275.16 | 29-APR-16:10 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 235.24 | 0.00 |
| May | 2240.45 | 10-MAY-16:30 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 177.88 | 0.00 |
| June | 2309.14 | 10-JUN-17:00 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 271.92 | 0.00 |
| July | 2247.00 | 22-JUL-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 77.84 | 0.00 |
| August | 2483.69 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 143.45 | 0.00 |
| September | 2595.30 | 10-SEP-16:10 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 121.09 | 0.00 |
| October | 2733.99 | 08-OCT-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 294.74 | 0.00 |
| November | 2382.74 | 02-NOV-15:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 96.93 | 0.00 |
| December | 2416.98 | 10-DEC-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 54.86 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2001.63 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 10.42 | 0.00 | |
| Maximum of Months | 2733.99 | 1187.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 294.74 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1212.10 | 19-JAN-16:20 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 21.00 | 0.00 |
| February | 1413.20 | 27-FEB-17:10 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1.68 | 0.00 |
| March | 1554.17 | 26-MAR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 53.40 | 0.00 |
| April | 2044.66 | 29-APR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 219.06 | 0.00 |
| May | 2208.98 | 10-MAY-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 177.88 | 0.00 |
| June | 2353.01 | 28-JUN-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 200.63 | 0.00 |
| July | 2310.32 | 07-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 161.18 | 0.00 |
| August | 2376.24 | 03-AUG-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 321.08 | 0.00 |
| September | 2310.66 | 09-SEP-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 287.72 | 0.00 |
| October | 2103.91 | 08-OCT-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 302.28 | 0.00 |
| November | 1630.46 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 71.81 | 0.00 |
| December | 1419.70 | 13-DEC-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 70.74 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1212.10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 1.68 | 0.00 | |
| Maximum of Months | 2376.24 | 1033.12 | 585.91 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 321.08 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2176.78 | 01-JAN-14:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 16.54 | 0.00 |
| February | 1926.57 | 02-FEB-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 144.29 | 0.00 |
| March | 1822.59 | 06-MAR-13:00 | 0.00 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 107.30 | 0.00 |
| April | 1934.72 | 29-APR-16:10 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 235.24 | 0.00 |
| May | 1922.32 | 18-MAY-16:40 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 251.61 | 0.00 |
| June | 1988.16 | 10-JUN-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 260.57 | 0.00 |
| July | 2241.67 | 19-JUL-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 0.00 |
| August | 2111.68 | 03-AUG-16:10 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 312.28 | 0.00 |
| September | 2364.32 | 10-SEP-12:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 174.95 | 0.00 |
| October | 2655.46 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 433.12 | 0.00 |
| November | 2186.66 | 07-NOV-13:30 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 120.35 | 0.00 |
| December | 2261.85 | 16-DEC-13:30 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.64 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1822.59 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 16.54 | 0.00 | |
| Maximum of Months | 2655.46 | 712.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1012.08 | 19-JAN-12:00 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 56.09 | 0.00 |
| February | 1087.15 | 24-FEB-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 83.56 | 0.00 |
| March | 1338.73 | 28-MAR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 88.37 | 0.00 |
| April | 1710.17 | 29-APR-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 235.24 | 0.00 |
| May | 1903.32 | 18-MAY-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 267.21 | 0.00 |
| June | 2005.76 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 227.14 | 0.00 |
| July | 2236.28 | 19-JUL-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 0.00 |
| August | 2062.99 | 03-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 314.91 | 0.00 |
| September | 1984.54 | 10-SEP-10:10 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 199.14 | 0.00 |
| October | 1814.15 | 08-OCT-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 302.28 | 0.00 |
| November | 1342.88 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 71.81 | 0.00 |
| December | 1150.78 | 16-DEC-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 101.22 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1012.08 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 56.09 | 0.00 | |
| Maximum of Months | 2236.28 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 552.55 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 868.15 | 02-JAN-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 4.41 | 0.00 |
| February | 902.72 | 24-FEB-17:03 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 | 0.00 |
| March | 1086.66 | 28-MAR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 53.30 | 0.00 |
| April | 1316.53 | 29-APR-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 141.89 | 0.00 |
| May | 1485.90 | 25-MAY-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 103.58 | 0.00 |
| June | 1586.95 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 137.01 | 0.00 |
| July | 1575.60 | 19-JUL-17:10 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 149.12 | 0.00 |
| August | 1573.96 | 03-AUG-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 191.51 | 0.00 |
| September | 1513.98 | 09-SEP-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 173.54 | 0.00 |
| October | 1418.39 | 08-OCT-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 182.33 | 0.00 |
| November | 1102.16 | 02-NOV-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 43.32 | 0.00 |
| December | 981.06 | 15-DEC-17:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 12.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 868.15 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 | 0.00 | |
| Maximum of Months | 1586.95 | 1033.12 | 585.91 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 191.51 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 866.03 | 02-JAN-17:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 4.41 | 0.00 |
| February | 898.46 | 24-FEB-17:03 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 | 0.00 |
| March | 1089.06 | 28-MAR-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 53.30 | 0.00 |
| April | 1313.94 | 29-APR-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 141.89 | 0.00 |
| May | 1482.71 | 25-MAY-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 103.58 | 0.00 |
| June | 1582.52 | 28-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 137.01 | 0.00 |
| July | 1575.54 | 19-JUL-17:10 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 149.12 | 0.00 |
| August | 1570.39 | 03-AUG-17:05 | 826.50 | 468.73 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 191.51 | 0.00 |
| September | 1508.50 | 09-SEP-17:04 | 1033.12 | 585.91 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 173.54 | 0.00 |
| October | 1414.23 | 08-OCT-16:10 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 182.33 | 0.00 |
| November | 1099.44 | 02-NOV-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 43.32 | 0.00 |
| December | 973.41 | 15-DEC-17:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 12.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 866.03 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 | 0.00 | |
| Maximum of Months | 1582.52 | 1033.12 | 585.91 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 191.51 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2001.62 | 01-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 8.97 | 0.00 |
| February | 1715.56 | 27-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 18.34 | 0.00 |
| March | 1545.55 | 05-MAR-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 50.47 | 0.00 |
| April | 1539.43 | 29-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 141.89 | 0.00 |
| May | 1475.34 | 18-MAY-16:40 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 151.77 | 0.00 |
| June | 1541.16 | 10-JUN-16:50 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 161.95 | 0.00 |
| July | 1566.87 | 23-JUL-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 115.86 | 0.00 |
| August | 1669.51 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 86.52 | 0.00 |
| September | 1812.28 | 10-SEP-16:08 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 73.04 | 0.00 |
| October | 2145.70 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 0.00 |
| November | 1894.79 | 06-NOV-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 16.65 | 0.00 |
| December | 2027.51 | 10-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 31.33 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1475.34 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 8.97 | 0.00 | |
| Maximum of Months | 2145.70 | 1187.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2003.48 | 01-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 8.97 | 0.00 |
| February | 1715.22 | 27-FEB-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 18.34 | 0.00 |
| March | 1549.07 | 05-MAR-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 50.47 | 0.00 |
| April | 1536.68 | 29-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 141.89 | 0.00 |
| May | 1474.12 | 18-MAY-16:40 | 0.00 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 151.77 | 0.00 |
| June | 1537.62 | 10-JUN-16:50 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 161.95 | 0.00 |
| July | 1569.58 | 23-JUL-16:05 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 115.86 | 0.00 |
| August | 1666.43 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 86.52 | 0.00 |
| September | 1809.08 | 10-SEP-16:08 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 73.04 | 0.00 |
| October | 2148.10 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 0.00 |
| November | 1896.64 | 06-NOV-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 16.65 | 0.00 |
| December | 2028.94 | 10-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 31.33 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1474.12 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 8.97 | 0.00 | |
| Maximum of Months | 2148.10 | 1187.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 261.25 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2983.95 | 01-JAN-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 13.92 | 0.00 |
| February | 2864.02 | 27-FEB-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 36.22 | 0.00 |
| March | 2626.61 | 26-MAR-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 72.89 | 0.00 |
| April | 3139.94 | 29-APR-16:07 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 309.04 | 0.00 |
| May | 3202.62 | 10-MAY-16:15 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 242.07 | 0.00 |
| June | 3240.09 | 10-JUN-16:40 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 348.64 | 0.00 |
| July | 3253.44 | 22-JUL-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 102.62 | 0.00 |
| August | 3520.64 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 189.13 | 0.00 |
| September | 3630.76 | 10-SEP-16:04 | 1187.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 159.55 | 0.00 |
| October | 3736.25 | 08-OCT-15:30 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 387.67 | 0.00 |
| November | 3259.82 | 02-NOV-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 133.49 | 0.00 |
| December | 3158.53 | 10-DEC-15:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 77.66 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2626.61 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 13.92 | 0.00 | |
| Maximum of Months | 3736.25 | 1187.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 387.67 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1600.90 | 31-JAN-16:20 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 11.79 | 0.00 |
| February | 1771.08 | 27-FEB-17:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1.31 | 0.00 |
| March | 2122.31 | 26-MAR-16:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 72.89 | 0.00 |
| April | 2891.22 | 28-APR-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 200.73 | 0.00 |
| May | 3138.41 | 10-MAY-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 234.20 | 0.00 |
| June | 3243.36 | 28-JUN-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 264.16 | 0.00 |
| July | 3278.08 | 07-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 212.32 | 0.00 |
| August | 3360.15 | 03-AUG-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 418.12 | 0.00 |
| September | 3227.90 | 09-SEP-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 376.00 | 0.00 |
| October | 2862.82 | 08-OCT-16:07 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 397.47 | 0.00 |
| November | 2186.69 | 02-NOV-16:03 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 94.18 | 0.00 |
| December | 1880.85 | 13-DEC-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 92.77 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1600.90 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 1.31 | 0.00 | |
| Maximum of Months | 3360.15 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 418.12 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2823.18 | 01-JAN-14:20 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 20.16 | 0.00 |
| February | 2543.36 | 27-FEB-14:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 35.17 | 0.00 |
| March | 2409.44 | 06-MAR-13:40 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 129.09 | 0.00 |
| April | 2700.87 | 28-APR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 261.06 | 0.00 |
| May | 2764.74 | 07-MAY-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 289.92 | 0.00 |
| June | 2757.05 | 10-JUN-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 343.21 | 0.00 |
| July | 3194.03 | 19-JUL-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 0.00 |
| August | 2979.18 | 03-AUG-16:10 | 0.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 411.63 | 0.00 |
| September | 3405.56 | 10-SEP-13:00 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 226.84 | 0.00 |
| October | 3586.71 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 569.67 | 0.00 |
| November | 3051.48 | 02-NOV-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 102.55 | 0.00 |
| December | 3002.88 | 16-DEC-13:30 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 115.92 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2409.44 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 20.16 | 0.00 | |
| Maximum of Months | 3586.71 | 237.50 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1251.59 | 19-JAN-12:50 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 62.62 | 0.00 |
| February | 1366.69 | 24-FEB-14:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 69.06 | 0.00 |
| March | 1883.44 | 26-MAR-14:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 116.87 | 0.00 |
| April | 2383.23 | 28-APR-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 261.06 | 0.00 |
| May | 2601.30 | 18-MAY-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 299.41 | 0.00 |
| June | 2719.78 | 28-JUN-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 289.04 | 0.00 |
| July | 3170.01 | 19-JUL-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 0.00 |
| August | 2885.77 | 03-AUG-16:08 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 411.63 | 0.00 |
| September | 2807.61 | 10-SEP-12:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 230.61 | 0.00 |
| October | 2495.06 | 07-OCT-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 231.59 | 0.00 |
| November | 1821.59 | 02-NOV-14:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 120.46 | 0.00 |
| December | 1517.80 | 16-DEC-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 132.56 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1251.59 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 62.62 | 0.00 | |
| Maximum of Months | 3170.01 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 727.97 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1082.10 | 31-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 16.25 | 0.00 |
| February | 1095.18 | 27-FEB-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 21.84 | 0.00 |
| March | 1477.07 | 26-MAR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 41.71 | 0.00 |
| April | 1932.45 | 28-APR-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 121.08 | 0.00 |
| May | 2118.14 | 28-MAY-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 122.88 | 0.00 |
| June | 2224.84 | 28-JUN-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 159.33 | 0.00 |
| July | 2294.45 | 19-JUL-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 0.00 |
| August | 2290.30 | 03-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 250.36 | 0.00 |
| September | 2168.80 | 09-SEP-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 220.92 | 0.00 |
| October | 1962.38 | 08-OCT-16:03 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 239.74 | 0.00 |
| November | 1469.65 | 02-NOV-16:05 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 56.80 | 0.00 |
| December | 1250.94 | 15-DEC-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 50.88 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1082.10 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 16.25 | 0.00 | |
| Maximum of Months | 2294.45 | 741.00 | 520.80 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 1074.12 | 31-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 16.25 | 0.00 |
| February | 1088.38 | 27-FEB-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 21.84 | 0.00 |
| March | 1471.60 | 26-MAR-16:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 43.96 | 0.00 |
| April | 1922.11 | 28-APR-16:04 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 121.08 | 0.00 |
| May | 2108.32 | 28-MAY-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 122.88 | 0.00 |
| June | 2213.09 | 28-JUN-17:30 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 159.33 | 0.00 |
| July | 2303.97 | 19-JUL-13:00 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 0.00 |
| August | 2282.14 | 03-AUG-16:17 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 250.36 | 0.00 |
| September | 2157.41 | 09-SEP-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 220.92 | 0.00 |
| October | 1952.18 | 08-OCT-16:03 | 370.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 239.74 | 0.00 |
| November | 1464.28 | 02-NOV-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 80.52 | 0.00 |
| December | 1243.92 | 15-DEC-15:10 | 59.38 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 50.88 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1074.12 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 16.25 | 0.00 | |
| Maximum of Months | 2303.97 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2635.07 | 01-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11.55 | 0.00 |
| February | 2293.31 | 27-FEB-14:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 | 0.00 |
| March | 2034.53 | 06-MAR-14:20 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 67.50 | 0.00 |
| April | 2220.09 | 28-APR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 157.47 | 0.00 |
| May | 2179.72 | 10-MAY-16:04 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 150.82 | 0.00 |
| June | 2238.20 | 10-JUN-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 207.01 | 0.00 |
| July | 2323.81 | 22-JUL-16:17 | 712.50 | 260.40 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 67.05 | 0.00 |
| August | 2452.40 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 114.08 | 0.00 |
| September | 2710.08 | 10-SEP-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 124.01 | 0.00 |
| October | 2972.06 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 0.00 |
| November | 2647.78 | 02-NOV-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 72.66 | 0.00 |
| December | 2676.80 | 10-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 40.98 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2034.53 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11.55 | 0.00 | |
| Maximum of Months | 2972.06 | 712.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2638.80 | 01-JAN-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11.55 | 0.00 |
| February | 2296.48 | 27-FEB-14:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 | 0.00 |
| March | 2043.46 | 06-MAR-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 74.08 | 0.00 |
| April | 2216.34 | 28-APR-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 157.47 | 0.00 |
| May | 2170.87 | 10-MAY-16:04 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 150.82 | 0.00 |
| June | 2228.94 | 10-JUN-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 207.01 | 0.00 |
| July | 2325.34 | 19-JUL-13:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 0.00 |
| August | 2442.60 | 30-AUG-16:03 | 0.00 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 114.08 | 0.00 |
| September | 2716.81 | 10-SEP-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 124.01 | 0.00 |
| October | 2976.22 | 09-OCT-14:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 343.61 | 0.00 |
| November | 2651.78 | 02-NOV-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 72.66 | 0.00 |
| December | 2679.05 | 10-DEC-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 40.98 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2043.46 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11.55 | 0.00 | |
| Maximum of Months | 2976.22 | 237.50 | 607.59 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 439.10 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.73 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.94 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.66 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.61 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.75 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.24 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.61 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.94 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.45 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.80 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.34 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.97 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.45 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.73 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.18 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.20 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.71 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.61 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.03 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.68 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.72 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.73 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.37 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.58 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.56 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.43 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.24 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.19 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.76 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.37 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.70 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.27 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.10 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.94 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.61 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.61 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.984683E+11 | 81985.13 | 01-JAN-17:49 | 0.888708E+10 | 30336.17 | 10-JAN-04:00 |
| February | 0.914279E+11 | 72982.21 | 02-FEB-18:49 | 0.603485E+10 | 50436.00 | 05-FEB-07:19 |
| March | 0.101957E+12 | 76869.08 | 07-MAR-18:49 | 0.427740E+10 | 22983.12 | 11-MAR-10:09 |
| April | 0.108229E+12 | 84691.02 | 29-APR-16:40 | 16865129.89 | 1411.00 | 11-APR-05:00 |
| May | 0.135642E+12 | 88465.90 | 25-MAY-17:49 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 0.133473E+12 | 87264.42 | 08-JUN-16:19 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 0.141948E+12 | 91328.99 | 18-JUL-16:30 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 0.140977E+12 | 94047.51 | 03-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 0.132864E+12 | 97430.93 | 09-SEP-17:30 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 0.130313E+12 | 90326.24 | 08-OCT-17:19 | 61705666.61 | 2728.17 | 28-OCT-05:00 |
| November | 0.105177E+12 | 79202.16 | 01-NOV-17:49 | 0.705326E+09 | 6747.29 | 16-NOV-04:00 |
| December | 0.103044E+12 | 72917.80 | 16-DEC-18:30 | 0.613081E+10 | 34595.15 | 21-DEC-06:00 |
| Annual Sum or Average | 0.142352E+13 | 0.261140E+11 | ||||
| Minimum of Months | 0.914279E+11 | 72917.80 | 0.00 | 0.00 | ||
| Maximum of Months | 0.141948E+12 | 97430.93 | 0.888708E+10 | 50436.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.480555E+10 | 0.389380E+11 | 0.00 | 0.608253E+10 | 0.00 | 0.00 | 0.491824E+10 | 0.00 | 0.00 | 0.00 | 0.353147E+11 | 0.00 |
| February | 0.760941E+10 | 0.415043E+10 | 0.351823E+11 | 0.00 | 0.602191E+10 | 0.00 | 0.00 | 0.678804E+10 | 0.00 | 0.00 | 0.00 | 0.316758E+11 | 0.00 |
| March | 0.845392E+10 | 0.430896E+10 | 0.389781E+11 | 0.00 | 0.699440E+10 | 0.00 | 0.00 | 0.913112E+10 | 0.00 | 0.00 | 0.00 | 0.340903E+11 | 0.00 |
| April | 0.814762E+10 | 0.389258E+10 | 0.376905E+11 | 0.00 | 0.897129E+10 | 0.00 | 0.00 | 0.180753E+11 | 0.00 | 0.00 | 0.00 | 0.314516E+11 | 0.00 |
| May | 0.843904E+10 | 0.377225E+10 | 0.389647E+11 | 0.00 | 0.142581E+11 | 0.00 | 0.00 | 0.393565E+11 | 0.00 | 0.00 | 0.00 | 0.308509E+11 | 0.00 |
| June | 0.817737E+10 | 0.351440E+10 | 0.377173E+11 | 0.00 | 0.144318E+11 | 0.00 | 0.00 | 0.410491E+11 | 0.00 | 0.00 | 0.00 | 0.285826E+11 | 0.00 |
| July | 0.840929E+10 | 0.370349E+10 | 0.389380E+11 | 0.00 | 0.157883E+11 | 0.00 | 0.00 | 0.462262E+11 | 0.00 | 0.00 | 0.00 | 0.288832E+11 | 0.00 |
| August | 0.845392E+10 | 0.390595E+10 | 0.389781E+11 | 0.00 | 0.155194E+11 | 0.00 | 0.00 | 0.450208E+11 | 0.00 | 0.00 | 0.00 | 0.290994E+11 | 0.00 |
| September | 0.814762E+10 | 0.405302E+10 | 0.376905E+11 | 0.00 | 0.141955E+11 | 0.00 | 0.00 | 0.396474E+11 | 0.00 | 0.00 | 0.00 | 0.291301E+11 | 0.00 |
| October | 0.842417E+10 | 0.447895E+10 | 0.389514E+11 | 0.00 | 0.129433E+11 | 0.00 | 0.00 | 0.338917E+11 | 0.00 | 0.00 | 0.00 | 0.316240E+11 | 0.00 |
| November | 0.814762E+10 | 0.457636E+10 | 0.376905E+11 | 0.00 | 0.806472E+10 | 0.00 | 0.00 | 0.144855E+11 | 0.00 | 0.00 | 0.00 | 0.322120E+11 | 0.00 |
| December | 0.840929E+10 | 0.486858E+10 | 0.389380E+11 | 0.00 | 0.705068E+10 | 0.00 | 0.00 | 0.911787E+10 | 0.00 | 0.00 | 0.00 | 0.346597E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.500305E+11 | 0.458657E+12 | 0.00 | 0.130322E+12 | 0.00 | 0.00 | 0.307708E+12 | 0.00 | 0.00 | 0.00 | 0.377574E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.351440E+10 | 0.351823E+11 | 0.00 | 0.602191E+10 | 0.00 | 0.00 | 0.491824E+10 | 0.00 | 0.00 | 0.00 | 0.285826E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.486858E+10 | 0.389781E+11 | 0.00 | 0.157883E+11 | 0.00 | 0.00 | 0.462262E+11 | 0.00 | 0.00 | 0.00 | 0.353147E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.888708E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.603485E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.427740E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 16865129.89 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 61705666.61 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.705326E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.613081E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.261140E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.888708E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 6009.72 | 19-JAN-15:09 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 5787.83 | 02-FEB-13:30 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 5822.16 | 06-MAR-16:10 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 7589.30 | 29-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 7529.13 | 28-MAY-16:10 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 8010.00 | 28-JUN-17:30 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 8461.71 | 22-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 8547.04 | 03-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 9041.49 | 09-SEP-16:00 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 8918.00 | 08-OCT-13:00 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 7271.59 | 02-NOV-15:09 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 6617.35 | 16-DEC-12:00 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 5787.83 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 9041.49 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 17422.83 | 19-JAN-15:09 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 37238.61 | 03-JAN-07:30 | 0.00 |
| February | 17165.25 | 02-FEB-12:00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 31147.60 | 04-FEB-06:19 | 0.00 |
| March | 16922.79 | 30-MAR-12:00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 33437.58 | 03-MAR-06:49 | 0.00 |
| April | 24034.51 | 29-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 30676.92 | 28-APR-05:40 | 0.00 |
| May | 25404.23 | 25-MAY-14:09 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 32415.78 | 10-MAY-06:40 | 0.00 |
| June | 27874.01 | 28-JUN-15:09 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 32275.92 | 02-JUN-07:49 | 0.00 |
| July | 29848.06 | 19-JUL-12:00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 30757.29 | 14-JUL-06:19 | 0.00 |
| August | 30183.98 | 03-AUG-15:00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 29814.66 | 25-AUG-06:19 | 0.00 |
| September | 32365.15 | 09-SEP-16:00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 29690.98 | 29-SEP-07:00 | 0.00 |
| October | 31159.33 | 08-OCT-13:00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 32004.58 | 27-OCT-07:30 | 0.00 |
| November | 23756.05 | 02-NOV-15:09 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 30063.17 | 14-NOV-06:40 | 0.00 |
| December | 20174.20 | 15-DEC-13:00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 33556.89 | 19-DEC-07:30 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 16922.79 | 0.00 | 0.00 | 0.00 | 29690.98 | 0.00 | |||
| Maximum of Months | 32365.15 | 0.00 | 0.00 | 0.00 | 37238.61 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 81985.13 | 01-JAN-17:49 | 4289.87 | 22609.62 | 3183.33 | 0.00 | 4539.08 | 0.00 | 0.00 | 10687.32 | 0.00 |
| February | 72982.21 | 02-FEB-18:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 4294.62 | 0.00 | 0.00 | 9839.16 | 0.00 |
| March | 76869.08 | 07-MAR-18:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 4794.65 | 0.00 | 0.00 | 11725.49 | 0.00 |
| April | 84691.02 | 29-APR-16:40 | 4289.87 | 22609.62 | 0.00 | 0.00 | 7361.96 | 0.00 | 0.00 | 22932.50 | 0.00 |
| May | 88465.90 | 25-MAY-17:49 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7343.37 | 0.00 | 0.00 | 23366.29 | 0.00 |
| June | 87264.42 | 08-JUN-16:19 | 4289.87 | 22709.69 | 0.00 | 0.00 | 7210.11 | 0.00 | 0.00 | 22883.62 | 0.00 |
| July | 91328.99 | 18-JUL-16:30 | 4289.87 | 22709.69 | 0.00 | 0.00 | 8047.50 | 0.00 | 0.00 | 27364.83 | 0.00 |
| August | 94047.51 | 03-AUG-16:10 | 4289.87 | 22709.69 | 0.00 | 0.00 | 8547.04 | 0.00 | 0.00 | 29580.69 | 0.00 |
| September | 97430.93 | 09-SEP-17:30 | 5231.74 | 22609.62 | 0.00 | 0.00 | 8897.41 | 0.00 | 0.00 | 31556.70 | 0.00 |
| October | 90326.24 | 08-OCT-17:19 | 5231.74 | 22609.62 | 0.00 | 0.00 | 7943.48 | 0.00 | 0.00 | 25329.24 | 0.00 |
| November | 79202.16 | 01-NOV-17:49 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 5762.62 | 0.00 | 0.00 | 16120.20 | 0.00 |
| December | 72917.80 | 16-DEC-18:30 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 5234.48 | 0.00 | 0.00 | 13366.30 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 72917.80 | 4289.87 | 22609.62 | 0.00 | 0.00 | 4294.62 | 0.00 | 0.00 | 9839.16 | 0.00 | |
| Maximum of Months | 97430.93 | 5231.74 | 22709.69 | 3183.33 | 0.00 | 8897.41 | 0.00 | 0.00 | 31556.70 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 30336.17 | 10-JAN-04:00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 50436.00 | 05-FEB-07:19 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 22983.12 | 11-MAR-10:09 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 1411.00 | 11-APR-05:00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 2728.17 | 28-OCT-05:00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 6747.29 | 16-NOV-04:00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 34595.15 | 21-DEC-06:00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 50436.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.60 | 0.17 | 24.60 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.17 | 24.60 | 0.17 | 24.60 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.60 | 0.17 | 24.60 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 388.33 | 22.80 | 146.17 | 23.11 | 45.67 | 23.17 |
| February | 295.67 | 22.67 | 197.67 | 23.17 | 42.83 | 23.20 |
| March | 367.00 | 22.89 | 179.50 | 23.23 | 100.17 | 23.34 |
| April | 202.33 | 23.81 | 330.00 | 23.92 | 127.00 | 23.94 |
| May | 273.17 | 24.00 | 515.00 | 24.00 | 273.17 | 24.00 |
| June | 252.50 | 24.00 | 492.00 | 24.00 | 252.50 | 24.00 |
| July | 358.83 | 24.00 | 533.00 | 24.00 | 358.83 | 24.00 |
| August | 265.50 | 24.00 | 506.00 | 24.00 | 265.50 | 24.00 |
| September | 251.83 | 24.00 | 510.00 | 24.00 | 251.83 | 24.00 |
| October | 176.17 | 23.98 | 455.00 | 24.00 | 161.50 | 24.00 |
| November | 122.17 | 23.79 | 275.17 | 23.94 | 40.50 | 23.94 |
| December | 280.83 | 23.01 | 204.33 | 23.42 | 45.83 | 23.47 |
| Annual Sum or Average | 3234.33 | 23.50 | 4343.83 | 23.78 | 1965.33 | 23.82 |
| Minimum of Months | 122.17 | 22.67 | 146.17 | 23.11 | 40.50 | 23.17 |
| Maximum of Months | 388.33 | 24.00 | 533.00 | 24.00 | 358.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 669.50 | 22.11 | 175.50 | 22.43 | 122.67 | 22.56 |
| February | 536.17 | 22.33 | 275.33 | 22.73 | 167.17 | 22.81 |
| March | 623.67 | 22.77 | 241.67 | 23.08 | 160.17 | 23.20 |
| April | 330.67 | 23.74 | 451.67 | 23.89 | 180.00 | 23.90 |
| May | 342.83 | 24.00 | 744.00 | 24.00 | 342.83 | 24.00 |
| June | 298.33 | 24.00 | 720.00 | 24.00 | 298.33 | 24.00 |
| July | 437.17 | 24.00 | 744.00 | 24.00 | 437.17 | 24.00 |
| August | 350.00 | 24.00 | 744.00 | 24.00 | 350.00 | 24.00 |
| September | 386.33 | 24.00 | 720.00 | 24.00 | 386.33 | 24.00 |
| October | 304.83 | 23.96 | 625.17 | 23.99 | 258.33 | 23.99 |
| November | 323.83 | 23.60 | 298.17 | 23.79 | 96.33 | 23.82 |
| December | 583.67 | 22.66 | 219.67 | 23.01 | 117.17 | 23.13 |
| Annual Sum or Average | 5187.00 | 23.24 | 5959.17 | 23.63 | 2916.50 | 23.69 |
| Minimum of Months | 298.33 | 22.11 | 175.50 | 22.43 | 96.33 | 22.56 |
| Maximum of Months | 669.50 | 24.00 | 744.00 | 24.00 | 437.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 55.50 | 23.73 | 47.83 | 23.96 | 5.33 | 24.02 |
| February | 37.00 | 23.70 | 75.50 | 24.02 | 6.00 | 24.06 |
| March | 61.00 | 23.82 | 78.00 | 24.03 | 8.00 | 24.11 |
| April | 10.83 | 24.98 | 115.83 | 24.29 | 9.67 | 24.35 |
| May | 31.00 | 25.22 | 154.00 | 24.41 | 31.00 | 24.52 |
| June | 31.17 | 25.22 | 154.00 | 24.41 | 31.17 | 24.53 |
| July | 29.17 | 25.20 | 140.00 | 24.42 | 29.17 | 24.53 |
| August | 32.67 | 25.23 | 161.00 | 24.42 | 32.67 | 24.53 |
| September | 27.17 | 25.27 | 140.00 | 24.41 | 27.17 | 24.53 |
| October | 17.83 | 25.33 | 141.00 | 24.37 | 17.83 | 24.47 |
| November | 9.33 | 25.25 | 117.33 | 24.32 | 9.33 | 24.38 |
| December | 31.17 | 23.89 | 71.33 | 24.11 | 7.33 | 24.18 |
| Annual Sum or Average | 373.83 | 24.51 | 1395.83 | 24.30 | 214.67 | 24.40 |
| Minimum of Months | 9.33 | 23.70 | 47.83 | 23.96 | 5.33 | 24.02 |
| Maximum of Months | 61.00 | 25.33 | 161.00 | 24.42 | 32.67 | 24.53 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 670.50 | 22.11 | 171.33 | 22.43 | 120.83 | 22.56 |
| February | 545.67 | 22.36 | 269.00 | 22.74 | 175.17 | 22.83 |
| March | 616.83 | 22.77 | 233.50 | 23.08 | 151.50 | 23.20 |
| April | 331.67 | 23.76 | 451.17 | 23.89 | 186.33 | 23.91 |
| May | 322.67 | 24.00 | 744.00 | 24.00 | 322.67 | 24.00 |
| June | 274.83 | 24.00 | 720.00 | 24.00 | 274.83 | 24.00 |
| July | 412.83 | 24.00 | 744.00 | 24.00 | 412.83 | 24.00 |
| August | 335.50 | 24.00 | 744.00 | 24.00 | 335.50 | 24.00 |
| September | 382.00 | 24.00 | 720.00 | 24.00 | 382.00 | 24.00 |
| October | 302.00 | 23.96 | 619.50 | 23.99 | 254.50 | 23.99 |
| November | 320.33 | 23.64 | 303.67 | 23.81 | 92.50 | 23.84 |
| December | 590.50 | 22.64 | 217.00 | 22.98 | 122.67 | 23.10 |
| Annual Sum or Average | 5105.33 | 23.23 | 5937.17 | 23.62 | 2831.33 | 23.68 |
| Minimum of Months | 274.83 | 22.11 | 171.33 | 22.43 | 92.50 | 22.56 |
| Maximum of Months | 670.50 | 24.00 | 744.00 | 24.00 | 412.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 671.67 | 22.34 | 160.67 | 22.62 | 113.83 | 22.76 |
| February | 519.67 | 22.49 | 256.50 | 22.94 | 130.83 | 23.05 |
| March | 580.50 | 22.94 | 228.33 | 23.24 | 143.67 | 23.35 |
| April | 275.50 | 23.87 | 449.67 | 23.95 | 160.83 | 23.96 |
| May | 328.50 | 24.00 | 744.00 | 24.00 | 328.50 | 24.00 |
| June | 307.67 | 24.00 | 720.00 | 24.00 | 307.67 | 24.00 |
| July | 480.50 | 24.00 | 744.00 | 24.00 | 480.50 | 24.00 |
| August | 400.67 | 24.00 | 744.00 | 24.00 | 400.67 | 24.00 |
| September | 427.00 | 24.00 | 720.00 | 24.00 | 427.00 | 24.00 |
| October | 304.33 | 23.99 | 615.83 | 24.00 | 267.00 | 24.00 |
| November | 298.67 | 23.78 | 306.83 | 23.89 | 103.33 | 23.91 |
| December | 560.00 | 22.88 | 215.33 | 23.18 | 114.50 | 23.28 |
| Annual Sum or Average | 5154.67 | 23.37 | 5905.17 | 23.70 | 2978.33 | 23.76 |
| Minimum of Months | 275.50 | 22.34 | 160.67 | 22.62 | 103.33 | 22.76 |
| Maximum of Months | 671.67 | 24.00 | 744.00 | 24.00 | 480.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 672.00 | 22.34 | 160.83 | 22.63 | 114.00 | 22.76 |
| February | 519.83 | 22.50 | 256.33 | 22.94 | 131.67 | 23.06 |
| March | 579.83 | 22.94 | 228.33 | 23.24 | 142.83 | 23.35 |
| April | 274.00 | 23.87 | 449.83 | 23.95 | 160.00 | 23.96 |
| May | 328.00 | 24.00 | 744.00 | 24.00 | 328.00 | 24.00 |
| June | 307.33 | 24.00 | 720.00 | 24.00 | 307.33 | 24.00 |
| July | 479.00 | 24.00 | 744.00 | 24.00 | 479.00 | 24.00 |
| August | 400.67 | 24.00 | 744.00 | 24.00 | 400.67 | 24.00 |
| September | 426.67 | 24.00 | 720.00 | 24.00 | 426.67 | 24.00 |
| October | 304.00 | 23.99 | 615.50 | 24.00 | 266.50 | 24.00 |
| November | 298.67 | 23.79 | 307.00 | 23.89 | 103.33 | 23.91 |
| December | 560.50 | 22.87 | 215.17 | 23.18 | 114.83 | 23.27 |
| Annual Sum or Average | 5150.50 | 23.37 | 5905.00 | 23.70 | 2974.83 | 23.76 |
| Minimum of Months | 274.00 | 22.34 | 160.83 | 22.63 | 103.33 | 22.76 |
| Maximum of Months | 672.00 | 24.00 | 744.00 | 24.00 | 479.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 339.67 | 23.28 | 155.50 | 23.50 | 41.17 | 23.54 |
| February | 250.33 | 23.08 | 210.83 | 23.49 | 34.67 | 23.52 |
| March | 301.17 | 23.08 | 189.33 | 23.44 | 69.50 | 23.51 |
| April | 170.67 | 23.93 | 334.50 | 23.98 | 117.50 | 23.98 |
| May | 264.50 | 24.00 | 515.00 | 24.00 | 264.50 | 24.00 |
| June | 259.50 | 24.00 | 492.00 | 24.00 | 259.50 | 24.00 |
| July | 393.67 | 24.00 | 533.00 | 24.00 | 393.67 | 24.00 |
| August | 289.67 | 24.00 | 506.00 | 24.00 | 289.67 | 24.00 |
| September | 261.67 | 24.00 | 510.00 | 24.00 | 261.67 | 24.00 |
| October | 172.33 | 24.00 | 456.67 | 24.00 | 160.67 | 24.00 |
| November | 81.33 | 23.95 | 304.67 | 23.99 | 40.50 | 23.99 |
| December | 230.67 | 23.39 | 215.17 | 23.68 | 35.67 | 23.71 |
| Annual Sum or Average | 3015.17 | 23.70 | 4422.67 | 23.88 | 1968.67 | 23.90 |
| Minimum of Months | 81.33 | 23.08 | 155.50 | 23.44 | 34.67 | 23.51 |
| Maximum of Months | 393.67 | 24.00 | 533.00 | 24.00 | 393.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 326.17 | 23.31 | 160.33 | 23.53 | 38.50 | 23.57 |
| February | 244.33 | 23.10 | 212.67 | 23.51 | 32.67 | 23.54 |
| March | 277.33 | 23.06 | 196.83 | 23.45 | 51.67 | 23.50 |
| April | 152.83 | 23.95 | 343.83 | 23.98 | 108.17 | 23.99 |
| May | 217.67 | 24.00 | 515.00 | 24.00 | 217.67 | 24.00 |
| June | 220.17 | 24.00 | 492.00 | 24.00 | 220.17 | 24.00 |
| July | 326.17 | 24.00 | 533.00 | 24.00 | 326.17 | 24.00 |
| August | 228.83 | 24.00 | 506.00 | 24.00 | 228.83 | 24.00 |
| September | 194.67 | 24.00 | 510.00 | 24.00 | 194.67 | 24.00 |
| October | 146.83 | 24.00 | 460.33 | 24.00 | 137.83 | 24.00 |
| November | 62.00 | 23.96 | 318.67 | 23.99 | 25.17 | 23.99 |
| December | 206.67 | 23.39 | 220.50 | 23.70 | 21.33 | 23.72 |
| Annual Sum or Average | 2603.67 | 23.68 | 4469.17 | 23.88 | 1602.83 | 23.90 |
| Minimum of Months | 62.00 | 23.06 | 160.33 | 23.45 | 21.33 | 23.50 |
| Maximum of Months | 326.17 | 24.00 | 533.00 | 24.00 | 326.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 374.50 | 22.69 | 152.67 | 23.05 | 46.67 | 23.12 |
| February | 236.00 | 22.70 | 216.17 | 23.28 | 31.17 | 23.29 |
| March | 266.50 | 22.88 | 208.67 | 23.37 | 55.33 | 23.44 |
| April | 133.50 | 23.90 | 359.33 | 23.97 | 94.17 | 23.98 |
| May | 229.00 | 24.00 | 515.00 | 24.00 | 229.00 | 24.00 |
| June | 217.00 | 24.00 | 492.00 | 24.00 | 217.00 | 24.00 |
| July | 355.67 | 24.00 | 533.00 | 24.00 | 355.67 | 24.00 |
| August | 312.67 | 24.00 | 506.00 | 24.00 | 312.67 | 24.00 |
| September | 338.33 | 24.00 | 510.00 | 24.00 | 338.33 | 24.00 |
| October | 239.00 | 23.95 | 438.83 | 23.98 | 204.33 | 23.99 |
| November | 170.17 | 23.69 | 249.83 | 23.87 | 57.83 | 23.89 |
| December | 307.00 | 22.87 | 194.33 | 23.31 | 56.67 | 23.38 |
| Annual Sum or Average | 3179.33 | 23.52 | 4375.83 | 23.80 | 1998.83 | 23.84 |
| Minimum of Months | 133.50 | 22.69 | 152.67 | 23.05 | 31.17 | 23.12 |
| Maximum of Months | 374.50 | 24.00 | 533.00 | 24.00 | 355.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 646.83 | 22.04 | 174.83 | 22.38 | 114.50 | 22.52 |
| February | 431.17 | 22.36 | 296.67 | 22.91 | 88.00 | 22.92 |
| March | 474.50 | 22.82 | 265.33 | 23.23 | 102.00 | 23.31 |
| April | 206.00 | 23.86 | 493.83 | 23.96 | 121.00 | 23.96 |
| May | 289.50 | 24.00 | 744.00 | 24.00 | 289.50 | 24.00 |
| June | 253.50 | 24.00 | 720.00 | 24.00 | 253.50 | 24.00 |
| July | 445.33 | 24.00 | 744.00 | 24.00 | 445.33 | 24.00 |
| August | 433.83 | 24.00 | 744.00 | 24.00 | 433.83 | 24.00 |
| September | 494.50 | 24.00 | 720.00 | 24.00 | 494.50 | 24.00 |
| October | 379.00 | 23.90 | 600.17 | 23.96 | 308.50 | 23.97 |
| November | 383.50 | 23.47 | 291.00 | 23.70 | 109.67 | 23.74 |
| December | 599.50 | 22.53 | 234.17 | 22.88 | 136.83 | 22.99 |
| Annual Sum or Average | 5037.17 | 23.27 | 6028.00 | 23.65 | 2897.17 | 23.71 |
| Minimum of Months | 206.00 | 22.04 | 174.83 | 22.38 | 88.00 | 22.52 |
| Maximum of Months | 646.83 | 24.00 | 744.00 | 24.00 | 494.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 379.33 | 22.70 | 153.67 | 23.06 | 49.67 | 23.13 |
| February | 241.67 | 22.72 | 214.67 | 23.29 | 33.67 | 23.30 |
| March | 264.83 | 22.85 | 208.33 | 23.36 | 53.00 | 23.42 |
| April | 143.67 | 23.91 | 359.83 | 23.97 | 98.67 | 23.98 |
| May | 226.17 | 24.00 | 515.00 | 24.00 | 226.17 | 24.00 |
| June | 222.67 | 24.00 | 492.00 | 24.00 | 222.67 | 24.00 |
| July | 355.00 | 24.00 | 533.00 | 24.00 | 355.00 | 24.00 |
| August | 320.67 | 24.00 | 506.00 | 24.00 | 320.67 | 24.00 |
| September | 343.83 | 24.00 | 510.00 | 24.00 | 343.83 | 24.00 |
| October | 243.00 | 23.95 | 437.83 | 23.98 | 207.67 | 23.99 |
| November | 172.67 | 23.69 | 256.33 | 23.88 | 58.00 | 23.89 |
| December | 315.50 | 22.87 | 189.83 | 23.29 | 59.83 | 23.37 |
| Annual Sum or Average | 3229.00 | 23.52 | 4376.50 | 23.79 | 2028.83 | 23.84 |
| Minimum of Months | 143.67 | 22.70 | 153.67 | 23.06 | 33.67 | 23.13 |
| Maximum of Months | 379.33 | 24.00 | 533.00 | 24.00 | 355.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 650.00 | 22.05 | 171.83 | 22.39 | 115.33 | 22.53 |
| February | 433.83 | 22.38 | 298.83 | 22.92 | 91.83 | 22.94 |
| March | 459.00 | 22.81 | 270.00 | 23.25 | 86.33 | 23.33 |
| April | 197.17 | 23.88 | 495.00 | 23.97 | 119.50 | 23.97 |
| May | 272.00 | 24.00 | 744.00 | 24.00 | 272.00 | 24.00 |
| June | 230.17 | 24.00 | 720.00 | 24.00 | 230.17 | 24.00 |
| July | 416.83 | 24.00 | 744.00 | 24.00 | 416.83 | 24.00 |
| August | 422.67 | 24.00 | 744.00 | 24.00 | 422.67 | 24.00 |
| September | 481.00 | 24.00 | 720.00 | 24.00 | 481.00 | 24.00 |
| October | 381.83 | 23.91 | 599.50 | 23.96 | 305.00 | 23.97 |
| November | 388.17 | 23.51 | 294.67 | 23.72 | 114.00 | 23.76 |
| December | 609.67 | 22.52 | 229.00 | 22.87 | 141.17 | 22.98 |
| Annual Sum or Average | 4942.33 | 23.26 | 6030.83 | 23.65 | 2795.83 | 23.71 |
| Minimum of Months | 197.17 | 22.05 | 171.83 | 22.39 | 86.33 | 22.53 |
| Maximum of Months | 650.00 | 24.00 | 744.00 | 24.00 | 481.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 628.83 | 22.25 | 162.00 | 22.59 | 95.33 | 22.72 |
| February | 409.00 | 22.58 | 283.33 | 23.14 | 60.67 | 23.18 |
| March | 427.50 | 23.00 | 267.33 | 23.38 | 75.50 | 23.44 |
| April | 188.17 | 23.96 | 489.67 | 23.99 | 117.17 | 23.99 |
| May | 290.00 | 24.00 | 744.00 | 24.00 | 290.00 | 24.00 |
| June | 276.50 | 24.00 | 720.00 | 24.00 | 276.50 | 24.00 |
| July | 489.50 | 24.00 | 744.00 | 24.00 | 489.50 | 24.00 |
| August | 471.33 | 24.00 | 744.00 | 24.00 | 471.33 | 24.00 |
| September | 511.17 | 24.00 | 720.00 | 24.00 | 511.17 | 24.00 |
| October | 371.83 | 23.96 | 587.83 | 23.99 | 314.33 | 23.99 |
| November | 332.17 | 23.72 | 295.67 | 23.85 | 116.67 | 23.88 |
| December | 567.50 | 22.80 | 215.33 | 23.12 | 114.33 | 23.23 |
| Annual Sum or Average | 4963.50 | 23.42 | 5973.17 | 23.73 | 2932.50 | 23.78 |
| Minimum of Months | 188.17 | 22.25 | 162.00 | 22.59 | 60.67 | 22.72 |
| Maximum of Months | 628.83 | 24.00 | 744.00 | 24.00 | 511.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 628.83 | 22.25 | 162.17 | 22.58 | 95.33 | 22.72 |
| February | 409.17 | 22.59 | 283.17 | 23.14 | 60.83 | 23.19 |
| March | 426.00 | 23.00 | 268.00 | 23.39 | 75.33 | 23.45 |
| April | 187.83 | 23.96 | 489.83 | 23.99 | 117.17 | 23.99 |
| May | 289.33 | 24.00 | 744.00 | 24.00 | 289.33 | 24.00 |
| June | 276.00 | 24.00 | 720.00 | 24.00 | 276.00 | 24.00 |
| July | 487.67 | 24.00 | 744.00 | 24.00 | 487.67 | 24.00 |
| August | 470.67 | 24.00 | 744.00 | 24.00 | 470.67 | 24.00 |
| September | 510.67 | 24.00 | 720.00 | 24.00 | 510.67 | 24.00 |
| October | 371.67 | 23.96 | 587.67 | 23.99 | 314.00 | 23.99 |
| November | 331.83 | 23.73 | 296.00 | 23.85 | 116.33 | 23.88 |
| December | 568.33 | 22.80 | 215.33 | 23.12 | 115.00 | 23.23 |
| Annual Sum or Average | 4958.00 | 23.42 | 5974.17 | 23.73 | 2928.33 | 23.78 |
| Minimum of Months | 187.83 | 22.25 | 162.17 | 22.58 | 60.83 | 22.72 |
| Maximum of Months | 628.83 | 24.00 | 744.00 | 24.00 | 510.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 322.83 | 23.25 | 160.33 | 23.49 | 41.00 | 23.53 |
| February | 187.83 | 23.08 | 221.83 | 23.58 | 15.83 | 23.59 |
| March | 233.83 | 23.15 | 222.67 | 23.56 | 36.67 | 23.60 |
| April | 114.33 | 23.99 | 362.33 | 24.00 | 91.17 | 24.00 |
| May | 236.33 | 24.00 | 515.00 | 24.00 | 236.33 | 24.00 |
| June | 241.17 | 24.00 | 492.00 | 24.00 | 241.17 | 24.00 |
| July | 400.83 | 24.00 | 533.00 | 24.00 | 400.83 | 24.00 |
| August | 345.00 | 24.00 | 506.00 | 24.00 | 345.00 | 24.00 |
| September | 341.50 | 24.00 | 510.00 | 24.00 | 341.50 | 24.00 |
| October | 218.83 | 23.99 | 437.67 | 24.00 | 196.67 | 24.00 |
| November | 122.83 | 23.88 | 262.50 | 23.96 | 53.17 | 23.97 |
| December | 253.17 | 23.28 | 208.83 | 23.61 | 49.83 | 23.64 |
| Annual Sum or Average | 3018.50 | 23.73 | 4432.17 | 23.89 | 2049.17 | 23.91 |
| Minimum of Months | 114.33 | 23.08 | 160.33 | 23.49 | 15.83 | 23.53 |
| Maximum of Months | 400.83 | 24.00 | 533.00 | 24.00 | 400.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 323.50 | 23.25 | 160.67 | 23.49 | 41.00 | 23.53 |
| February | 188.17 | 23.08 | 221.83 | 23.58 | 16.00 | 23.59 |
| March | 233.83 | 23.15 | 222.50 | 23.57 | 36.83 | 23.60 |
| April | 114.17 | 23.99 | 362.17 | 24.00 | 91.00 | 24.00 |
| May | 236.50 | 24.00 | 515.00 | 24.00 | 236.50 | 24.00 |
| June | 241.00 | 24.00 | 492.00 | 24.00 | 241.00 | 24.00 |
| July | 400.00 | 24.00 | 533.00 | 24.00 | 400.00 | 24.00 |
| August | 345.17 | 24.00 | 506.00 | 24.00 | 345.17 | 24.00 |
| September | 341.83 | 24.00 | 510.00 | 24.00 | 341.83 | 24.00 |
| October | 219.00 | 23.99 | 437.67 | 24.00 | 196.67 | 24.00 |
| November | 122.83 | 23.88 | 262.50 | 23.96 | 53.17 | 23.97 |
| December | 253.33 | 23.28 | 208.67 | 23.60 | 49.83 | 23.64 |
| Annual Sum or Average | 3019.33 | 23.73 | 4432.00 | 23.89 | 2049.00 | 23.91 |
| Minimum of Months | 114.17 | 23.08 | 160.67 | 23.49 | 16.00 | 23.53 |
| Maximum of Months | 400.00 | 24.00 | 533.00 | 24.00 | 400.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 428.17 | 21.96 | 213.00 | 22.23 | 145.83 | 22.22 |
| February | 342.00 | 22.21 | 233.83 | 22.57 | 131.67 | 22.53 |
| March | 370.83 | 22.45 | 234.33 | 22.80 | 143.67 | 22.83 |
| April | 250.00 | 23.38 | 340.67 | 23.73 | 137.00 | 23.77 |
| May | 270.50 | 24.00 | 515.00 | 24.00 | 270.50 | 24.00 |
| June | 243.50 | 24.00 | 492.00 | 24.00 | 243.50 | 24.00 |
| July | 338.00 | 24.00 | 533.00 | 24.00 | 338.00 | 24.00 |
| August | 314.83 | 24.00 | 505.50 | 24.00 | 314.83 | 24.00 |
| September | 354.83 | 24.00 | 510.00 | 24.00 | 354.83 | 24.00 |
| October | 295.33 | 23.66 | 426.50 | 23.86 | 230.00 | 23.90 |
| November | 311.33 | 22.77 | 217.83 | 23.24 | 88.00 | 23.32 |
| December | 397.50 | 22.23 | 246.67 | 22.64 | 144.83 | 22.67 |
| Annual Sum or Average | 3916.83 | 23.13 | 4468.33 | 23.50 | 2542.67 | 23.54 |
| Minimum of Months | 243.50 | 21.96 | 213.00 | 22.23 | 88.00 | 22.22 |
| Maximum of Months | 428.17 | 24.00 | 533.00 | 24.00 | 354.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 665.67 | 21.81 | 346.33 | 21.97 | 290.17 | 21.96 |
| February | 528.67 | 22.12 | 360.50 | 22.43 | 234.33 | 22.40 |
| March | 570.33 | 22.36 | 337.50 | 22.71 | 212.00 | 22.75 |
| April | 335.67 | 23.31 | 476.67 | 23.70 | 170.50 | 23.75 |
| May | 336.50 | 24.00 | 744.00 | 24.00 | 336.50 | 24.00 |
| June | 286.33 | 24.00 | 720.00 | 24.00 | 286.33 | 24.00 |
| July | 413.17 | 24.00 | 744.00 | 24.00 | 413.17 | 24.00 |
| August | 417.00 | 24.00 | 743.50 | 24.00 | 417.00 | 24.00 |
| September | 481.17 | 24.00 | 720.00 | 24.00 | 481.17 | 24.00 |
| October | 424.33 | 23.61 | 595.17 | 23.83 | 320.17 | 23.87 |
| November | 506.17 | 22.67 | 289.67 | 23.06 | 159.00 | 23.14 |
| December | 628.83 | 22.09 | 340.33 | 22.38 | 256.67 | 22.41 |
| Annual Sum or Average | 5593.83 | 22.99 | 6417.67 | 23.39 | 3577.00 | 23.42 |
| Minimum of Months | 286.33 | 21.81 | 289.67 | 21.97 | 159.00 | 21.96 |
| Maximum of Months | 665.67 | 24.00 | 744.00 | 24.00 | 481.17 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 430.17 | 21.95 | 215.67 | 22.21 | 151.00 | 22.21 |
| February | 351.00 | 22.22 | 234.67 | 22.57 | 137.50 | 22.54 |
| March | 375.00 | 22.45 | 230.83 | 22.79 | 145.17 | 22.83 |
| April | 263.83 | 23.40 | 337.83 | 23.73 | 146.67 | 23.77 |
| May | 271.83 | 24.00 | 515.00 | 24.00 | 271.83 | 24.00 |
| June | 247.00 | 24.00 | 492.00 | 24.00 | 247.00 | 24.00 |
| July | 331.17 | 24.00 | 533.00 | 24.00 | 331.17 | 24.00 |
| August | 321.33 | 24.00 | 505.67 | 24.00 | 321.33 | 24.00 |
| September | 359.83 | 24.00 | 510.00 | 24.00 | 359.83 | 24.00 |
| October | 299.50 | 23.66 | 424.33 | 23.86 | 232.83 | 23.89 |
| November | 317.33 | 22.79 | 219.50 | 23.25 | 93.00 | 23.33 |
| December | 403.67 | 22.23 | 246.33 | 22.62 | 149.50 | 22.65 |
| Annual Sum or Average | 3971.67 | 23.13 | 4464.83 | 23.49 | 2586.83 | 23.53 |
| Minimum of Months | 247.00 | 21.95 | 215.67 | 22.21 | 93.00 | 22.21 |
| Maximum of Months | 430.17 | 24.00 | 533.00 | 24.00 | 359.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 671.33 | 21.80 | 343.50 | 21.96 | 290.50 | 21.96 |
| February | 531.67 | 22.11 | 359.50 | 22.44 | 230.17 | 22.42 |
| March | 557.83 | 22.35 | 335.33 | 22.72 | 199.17 | 22.75 |
| April | 342.67 | 23.37 | 477.67 | 23.72 | 175.33 | 23.76 |
| May | 323.67 | 24.00 | 744.00 | 24.00 | 323.67 | 24.00 |
| June | 276.17 | 24.00 | 720.00 | 24.00 | 276.17 | 24.00 |
| July | 393.67 | 24.00 | 744.00 | 24.00 | 393.67 | 24.00 |
| August | 404.00 | 24.00 | 743.50 | 24.00 | 404.00 | 24.00 |
| September | 476.67 | 24.00 | 720.00 | 24.00 | 476.67 | 24.00 |
| October | 425.00 | 23.60 | 587.50 | 23.83 | 316.83 | 23.86 |
| November | 518.50 | 22.72 | 287.00 | 23.10 | 163.67 | 23.19 |
| December | 636.67 | 22.08 | 341.50 | 22.35 | 267.17 | 22.39 |
| Annual Sum or Average | 5557.83 | 22.98 | 6403.50 | 23.39 | 3517.00 | 23.42 |
| Minimum of Months | 276.17 | 21.80 | 287.00 | 21.96 | 163.67 | 21.96 |
| Maximum of Months | 671.33 | 24.00 | 744.00 | 24.00 | 476.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 660.83 | 21.85 | 307.50 | 22.04 | 254.67 | 22.06 |
| February | 526.50 | 22.23 | 343.83 | 22.54 | 215.50 | 22.52 |
| March | 558.67 | 22.46 | 308.17 | 22.83 | 174.83 | 22.87 |
| April | 319.67 | 23.48 | 470.83 | 23.79 | 161.33 | 23.82 |
| May | 324.83 | 24.00 | 744.00 | 24.00 | 324.83 | 24.00 |
| June | 284.33 | 24.00 | 720.00 | 24.00 | 284.33 | 24.00 |
| July | 416.17 | 24.00 | 744.00 | 24.00 | 416.17 | 24.00 |
| August | 419.83 | 24.00 | 744.00 | 24.00 | 419.83 | 24.00 |
| September | 477.83 | 24.00 | 720.00 | 24.00 | 477.83 | 24.00 |
| October | 409.00 | 23.67 | 585.83 | 23.86 | 309.17 | 23.90 |
| November | 503.17 | 22.83 | 280.00 | 23.20 | 146.17 | 23.29 |
| December | 640.83 | 22.19 | 301.67 | 22.49 | 222.67 | 22.55 |
| Annual Sum or Average | 5541.67 | 23.05 | 6269.83 | 23.45 | 3407.33 | 23.49 |
| Minimum of Months | 284.33 | 21.85 | 280.00 | 22.04 | 146.17 | 22.06 |
| Maximum of Months | 660.83 | 24.00 | 744.00 | 24.00 | 477.83 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 660.17 | 21.84 | 308.33 | 22.04 | 255.33 | 22.06 |
| February | 526.17 | 22.22 | 345.00 | 22.54 | 215.67 | 22.53 |
| March | 558.67 | 22.47 | 308.00 | 22.83 | 174.33 | 22.88 |
| April | 318.83 | 23.48 | 471.17 | 23.79 | 160.83 | 23.82 |
| May | 325.00 | 24.00 | 744.00 | 24.00 | 325.00 | 24.00 |
| June | 283.00 | 24.00 | 720.00 | 24.00 | 283.00 | 24.00 |
| July | 414.83 | 24.00 | 744.00 | 24.00 | 414.83 | 24.00 |
| August | 419.00 | 24.00 | 744.00 | 24.00 | 419.00 | 24.00 |
| September | 478.00 | 24.00 | 720.00 | 24.00 | 478.00 | 24.00 |
| October | 409.50 | 23.67 | 586.00 | 23.86 | 309.33 | 23.90 |
| November | 502.83 | 22.83 | 280.33 | 23.20 | 146.50 | 23.29 |
| December | 640.83 | 22.19 | 303.00 | 22.48 | 224.50 | 22.54 |
| Annual Sum or Average | 5536.83 | 23.05 | 6273.83 | 23.45 | 3406.33 | 23.49 |
| Minimum of Months | 283.00 | 21.84 | 280.33 | 22.04 | 146.50 | 22.06 |
| Maximum of Months | 660.17 | 24.00 | 744.00 | 24.00 | 478.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 408.50 | 22.14 | 180.00 | 22.47 | 105.17 | 22.50 |
| February | 322.50 | 22.42 | 214.83 | 22.80 | 101.83 | 22.78 |
| March | 353.83 | 22.62 | 212.33 | 22.98 | 113.50 | 23.02 |
| April | 223.33 | 23.56 | 340.33 | 23.82 | 126.33 | 23.85 |
| May | 264.00 | 24.00 | 515.00 | 24.00 | 264.00 | 24.00 |
| June | 242.83 | 24.00 | 492.00 | 24.00 | 242.83 | 24.00 |
| July | 340.83 | 24.00 | 533.00 | 24.00 | 340.83 | 24.00 |
| August | 315.50 | 24.00 | 506.00 | 24.00 | 315.50 | 24.00 |
| September | 346.67 | 24.00 | 510.00 | 24.00 | 346.67 | 24.00 |
| October | 272.83 | 23.75 | 427.83 | 23.90 | 214.83 | 23.93 |
| November | 276.83 | 23.00 | 225.00 | 23.45 | 74.50 | 23.52 |
| December | 375.67 | 22.40 | 218.17 | 22.83 | 109.17 | 22.88 |
| Annual Sum or Average | 3743.33 | 23.25 | 4374.50 | 23.60 | 2355.17 | 23.64 |
| Minimum of Months | 223.33 | 22.14 | 180.00 | 22.47 | 74.50 | 22.50 |
| Maximum of Months | 408.50 | 24.00 | 533.00 | 24.00 | 346.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 408.67 | 22.14 | 180.33 | 22.47 | 105.67 | 22.49 |
| February | 323.17 | 22.42 | 214.83 | 22.80 | 102.50 | 22.78 |
| March | 353.50 | 22.61 | 212.67 | 22.98 | 113.83 | 23.02 |
| April | 223.83 | 23.56 | 339.50 | 23.82 | 126.50 | 23.85 |
| May | 264.33 | 24.00 | 515.00 | 24.00 | 264.33 | 24.00 |
| June | 243.33 | 24.00 | 492.00 | 24.00 | 243.33 | 24.00 |
| July | 339.67 | 24.00 | 533.00 | 24.00 | 339.67 | 24.00 |
| August | 315.33 | 24.00 | 506.00 | 24.00 | 315.33 | 24.00 |
| September | 347.00 | 24.00 | 510.00 | 24.00 | 347.00 | 24.00 |
| October | 273.17 | 23.75 | 427.67 | 23.90 | 215.17 | 23.93 |
| November | 277.17 | 23.00 | 225.33 | 23.45 | 74.50 | 23.52 |
| December | 377.00 | 22.40 | 217.67 | 22.83 | 109.50 | 22.88 |
| Annual Sum or Average | 3746.17 | 23.25 | 4374.00 | 23.60 | 2357.33 | 23.64 |
| Minimum of Months | 223.83 | 22.14 | 180.33 | 22.47 | 74.50 | 22.49 |
| Maximum of Months | 408.67 | 24.00 | 533.00 | 24.00 | 347.00 | 24.00 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 734.00 | 22.87 | 428.83 | 23.15 | 427.33 | 23.28 |
| February | 664.83 | 23.51 | 494.50 | 23.75 | 491.83 | 23.84 |
| March | 704.67 | 23.81 | 528.83 | 24.16 | 501.67 | 24.30 |
| April | 711.33 | 25.28 | 718.17 | 25.28 | 710.67 | 25.28 |
| May | 744.00 | 26.30 | 744.00 | 26.30 | 744.00 | 26.30 |
| June | 720.00 | 26.41 | 720.00 | 26.41 | 720.00 | 26.41 |
| July | 744.00 | 26.45 | 744.00 | 26.45 | 744.00 | 26.45 |
| August | 744.00 | 26.39 | 744.00 | 26.39 | 744.00 | 26.39 |
| September | 720.00 | 26.19 | 720.00 | 26.19 | 720.00 | 26.19 |
| October | 716.67 | 25.85 | 719.33 | 25.88 | 699.67 | 25.89 |
| November | 695.17 | 24.47 | 697.33 | 24.49 | 675.33 | 24.50 |
| December | 710.83 | 23.36 | 533.67 | 23.59 | 518.17 | 23.67 |
| Annual Sum or Average | 8609.50 | 25.10 | 7792.67 | 25.27 | 7696.67 | 25.34 |
| Minimum of Months | 664.83 | 22.87 | 428.83 | 23.15 | 427.33 | 23.28 |
| Maximum of Months | 744.00 | 26.45 | 744.00 | 26.45 | 744.00 | 26.45 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 676.67 | 22.54 | 255.33 | 22.84 | 212.17 | 22.93 |
| February | 619.50 | 23.09 | 341.50 | 23.41 | 314.00 | 23.54 |
| March | 623.67 | 23.44 | 354.67 | 23.86 | 298.67 | 24.01 |
| April | 489.33 | 25.34 | 620.67 | 25.44 | 433.67 | 25.50 |
| May | 744.00 | 26.81 | 744.00 | 26.81 | 744.00 | 26.81 |
| June | 720.00 | 27.07 | 720.00 | 27.07 | 720.00 | 27.07 |
| July | 744.00 | 27.20 | 744.00 | 27.20 | 744.00 | 27.20 |
| August | 744.00 | 27.18 | 744.00 | 27.18 | 744.00 | 27.18 |
| September | 720.00 | 26.88 | 720.00 | 26.88 | 720.00 | 26.88 |
| October | 597.83 | 26.71 | 704.33 | 26.67 | 582.83 | 26.72 |
| November | 425.00 | 25.00 | 528.50 | 25.29 | 312.50 | 25.42 |
| December | 594.50 | 23.40 | 351.50 | 23.92 | 250.17 | 24.09 |
| Annual Sum or Average | 7698.50 | 25.50 | 6828.50 | 25.84 | 6076.00 | 25.99 |
| Minimum of Months | 425.00 | 22.54 | 255.33 | 22.84 | 212.17 | 22.93 |
| Maximum of Months | 744.00 | 27.20 | 744.00 | 27.20 | 744.00 | 27.20 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 722.83 | 24.25 | 672.67 | 24.28 | 672.17 | 24.29 |
| February | 655.33 | 24.76 | 566.33 | 24.88 | 562.50 | 24.92 |
| March | 694.33 | 24.98 | 663.33 | 25.06 | 633.17 | 25.10 |
| April | 720.00 | 25.75 | 720.00 | 25.75 | 720.00 | 25.75 |
| May | 744.00 | 26.09 | 744.00 | 26.09 | 744.00 | 26.09 |
| June | 720.00 | 26.15 | 720.00 | 26.15 | 720.00 | 26.15 |
| July | 744.00 | 26.17 | 744.00 | 26.17 | 744.00 | 26.17 |
| August | 744.00 | 26.14 | 744.00 | 26.14 | 744.00 | 26.14 |
| September | 720.00 | 26.06 | 720.00 | 26.06 | 720.00 | 26.06 |
| October | 744.00 | 25.95 | 744.00 | 25.95 | 744.00 | 25.95 |
| November | 720.00 | 25.49 | 720.00 | 25.49 | 720.00 | 25.49 |
| December | 738.83 | 24.69 | 716.67 | 24.72 | 714.83 | 24.73 |
| Annual Sum or Average | 8667.33 | 25.55 | 8475.00 | 25.58 | 8438.67 | 25.59 |
| Minimum of Months | 655.33 | 24.25 | 566.33 | 24.28 | 562.50 | 24.29 |
| Maximum of Months | 744.00 | 26.17 | 744.00 | 26.17 | 744.00 | 26.17 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.755234E+09 | 0.186332E+09 | 277.60 | 0.595968E+09 | 0.159266E+09 | 0.00 | 0.42 | 19-JAN-15:30 | 0.00 | 02-JAN-07:15 | 2601.65 | 19-JAN-15:30 | 2169.59 | 01-JAN-16:10 | 646.45 | 19-JAN-10:40 | 627.07 | 19-JAN-15:30 | 0.00 | 01-JAN-00:10 |
| February | 0.869727E+09 | 0.214772E+09 | 294.08 | 0.675752E+09 | 0.193976E+09 | 0.00 | 0.38 | 27-FEB-16:10 | 0.00 | 01-FEB-06:05 | 2305.61 | 27-FEB-16:10 | 1930.97 | 27-FEB-16:10 | 486.45 | 24-FEB-11:10 | 568.75 | 27-FEB-16:10 | 0.00 | 01-FEB-00:10 |
| March | 0.929470E+09 | 0.231143E+09 | 330.19 | 0.704825E+09 | 0.224645E+09 | 0.00 | 0.35 | 06-MAR-16:10 | 0.00 | 01-MAR-06:40 | 2162.80 | 06-MAR-16:10 | 1661.64 | 06-MAR-16:10 | 651.73 | 07-MAR-17:03 | 534.87 | 06-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.187626E+10 | 0.472020E+09 | 577.97 | 0.143300E+10 | 0.443260E+09 | 0.00 | 0.47 | 29-APR-16:03 | 0.00 | 01-APR-17:30 | 2931.70 | 29-APR-16:03 | 2120.97 | 28-APR-16:10 | 819.90 | 29-APR-16:03 | 753.70 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.440769E+10 | 0.111974E+10 | 744.00 | 0.311184E+10 | 0.129585E+10 | 0.00 | 0.46 | 28-MAY-16:10 | 0.10 | 01-MAY-00:10 | 2793.86 | 28-MAY-17:10 | 2245.46 | 10-MAY-16:30 | 878.84 | 26-MAY-11:00 | 759.41 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.466819E+10 | 0.119643E+10 | 720.00 | 0.332490E+10 | 0.134329E+10 | 0.00 | 0.50 | 17-JUN-16:30 | 0.10 | 07-JUN-01:50 | 3078.73 | 17-JUN-16:30 | 2365.81 | 10-JUN-16:50 | 822.98 | 29-JUN-15:40 | 832.30 | 17-JUN-16:30 | 0.00 | 01-JUN-00:10 |
| July | 0.558450E+10 | 0.141979E+10 | 744.00 | 0.380713E+10 | 0.177737E+10 | 0.00 | 0.56 | 22-JUL-16:30 | 0.18 | 15-JUL-04:00 | 3379.31 | 22-JUL-16:30 | 2582.30 | 22-JUL-16:30 | 1050.03 | 03-JUL-16:13 | 950.94 | 22-JUL-16:06 | 0.00 | 01-JUL-00:10 |
| August | 0.588930E+10 | 0.148862E+10 | 744.00 | 0.415376E+10 | 0.173554E+10 | 0.00 | 0.58 | 03-AUG-16:02 | 0.17 | 17-AUG-02:50 | 3467.68 | 03-AUG-16:02 | 2900.33 | 30-AUG-16:03 | 1106.70 | 10-AUG-20:20 | 972.59 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.548017E+10 | 0.136204E+10 | 720.00 | 0.383148E+10 | 0.164869E+10 | 0.00 | 0.64 | 09-SEP-17:00 | 0.17 | 28-SEP-04:00 | 3938.62 | 10-SEP-16:02 | 3000.10 | 10-SEP-16:04 | 1149.40 | 18-SEP-14:30 | 1097.17 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.495158E+10 | 0.123302E+10 | 721.40 | 0.368414E+10 | 0.126745E+10 | 0.00 | 0.64 | 08-OCT-15:30 | 0.00 | 17-OCT-05:50 | 4099.89 | 08-OCT-15:30 | 2976.92 | 08-OCT-15:30 | 1253.34 | 24-OCT-13:30 | 1066.56 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.243922E+10 | 0.606374E+09 | 625.52 | 0.198739E+10 | 0.451824E+09 | 0.00 | 0.52 | 02-NOV-15:10 | 0.00 | 05-NOV-06:00 | 3199.05 | 02-NOV-15:10 | 2472.46 | 02-NOV-15:20 | 861.45 | 07-NOV-13:40 | 816.00 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.153363E+10 | 0.379286E+09 | 413.15 | 0.121817E+10 | 0.315457E+09 | 0.00 | 0.46 | 16-DEC-13:30 | 0.00 | 01-DEC-03:10 | 2845.08 | 16-DEC-13:30 | 2366.30 | 10-DEC-15:10 | 718.95 | 13-DEC-11:00 | 712.02 | 16-DEC-13:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.393850E+11 | 0.990957E+10 | 6911.91 | 0.285284E+11 | 0.108566E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.755234E+09 | 0.186332E+09 | 277.60 | 0.595968E+09 | 0.159266E+09 | 0.00 | 0.35 | 0.00 | 2162.80 | 1661.64 | 486.45 | 534.87 | 0.00 | |||||||
| Maximum of Months | 0.588930E+10 | 0.148862E+10 | 744.00 | 0.415376E+10 | 0.177737E+10 | 0.00 | 0.64 | 0.18 | 4099.89 | 3000.10 | 1253.34 | 1097.17 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.278826E+09 | 68601664.94 | 133.81 | 0.199418E+09 | 79408085.68 | 0.00 | 0.26 | 19-JAN-16:10 | 0.00 | 01-JAN-06:03 | 1532.70 | 19-JAN-16:10 | 1160.70 | 01-JAN-16:10 | 466.43 | 19-JAN-15:20 | 373.15 | 19-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.377082E+09 | 93248893.58 | 166.68 | 0.271480E+09 | 0.105602E+09 | 0.00 | 0.26 | 27-FEB-17:05 | 0.00 | 01-FEB-03:20 | 1507.74 | 27-FEB-17:05 | 1172.37 | 27-FEB-17:05 | 379.23 | 28-FEB-17:20 | 367.85 | 27-FEB-17:05 | 0.00 | 01-FEB-00:10 |
| March | 0.576802E+09 | 0.143309E+09 | 249.32 | 0.411983E+09 | 0.164818E+09 | 0.00 | 0.28 | 29-MAR-16:03 | 0.00 | 01-MAR-02:40 | 1636.43 | 28-MAR-16:10 | 1203.07 | 29-MAR-16:10 | 573.23 | 07-MAR-17:03 | 407.82 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.159063E+10 | 0.399940E+09 | 533.83 | 0.118532E+10 | 0.405312E+09 | 0.00 | 0.45 | 29-APR-16:03 | 0.00 | 01-APR-16:00 | 2681.73 | 29-APR-16:03 | 1957.99 | 28-APR-16:10 | 776.76 | 29-APR-16:03 | 695.24 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.439382E+10 | 0.111395E+10 | 744.00 | 0.309518E+10 | 0.129864E+10 | 0.00 | 0.47 | 28-MAY-17:10 | 0.10 | 01-MAY-00:10 | 2785.86 | 28-MAY-17:10 | 2217.60 | 10-MAY-16:30 | 892.16 | 26-MAY-11:00 | 741.70 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.476420E+10 | 0.121800E+10 | 720.00 | 0.340316E+10 | 0.136104E+10 | 0.00 | 0.54 | 28-JUN-17:30 | 0.10 | 07-JUN-01:50 | 3168.85 | 28-JUN-17:30 | 2429.33 | 28-JUN-17:30 | 844.68 | 29-JUN-15:40 | 849.51 | 28-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.562124E+10 | 0.142584E+10 | 744.00 | 0.383712E+10 | 0.178412E+10 | 0.00 | 0.57 | 22-JUL-16:30 | 0.19 | 15-JUL-04:00 | 3337.93 | 03-JUL-16:40 | 2538.31 | 07-JUL-16:30 | 1079.83 | 03-JUL-16:30 | 921.77 | 22-JUL-16:30 | 0.00 | 01-JUL-00:10 |
| August | 0.574492E+10 | 0.144948E+10 | 744.00 | 0.402154E+10 | 0.172338E+10 | 0.00 | 0.60 | 03-AUG-16:13 | 0.18 | 17-AUG-02:50 | 3444.24 | 03-AUG-16:40 | 2763.50 | 03-AUG-16:50 | 1094.45 | 10-AUG-20:20 | 960.51 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.509158E+10 | 0.126461E+10 | 720.00 | 0.349239E+10 | 0.159919E+10 | 0.00 | 0.63 | 09-SEP-17:00 | 0.17 | 28-SEP-04:00 | 3650.95 | 09-SEP-17:10 | 2774.13 | 09-SEP-17:04 | 1113.61 | 18-SEP-16:13 | 1028.53 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.414093E+10 | 0.103259E+10 | 700.62 | 0.296083E+10 | 0.118010E+10 | 0.00 | 0.57 | 08-OCT-16:03 | 0.00 | 17-OCT-05:30 | 3451.48 | 08-OCT-16:03 | 2417.25 | 08-OCT-16:07 | 1160.96 | 24-OCT-13:40 | 883.49 | 08-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.143215E+10 | 0.355102E+09 | 467.51 | 0.106558E+10 | 0.366573E+09 | 0.00 | 0.42 | 02-NOV-16:03 | 0.00 | 05-NOV-05:03 | 2469.62 | 02-NOV-16:03 | 1817.02 | 02-NOV-16:03 | 753.27 | 07-NOV-14:00 | 629.08 | 02-NOV-16:03 | 0.00 | 01-NOV-00:10 |
| December | 0.816078E+09 | 0.200715E+09 | 249.89 | 0.579207E+09 | 0.236871E+09 | 0.00 | 0.34 | 13-DEC-15:10 | 0.00 | 01-DEC-00:20 | 1982.33 | 14-DEC-16:10 | 1557.80 | 13-DEC-16:10 | 657.92 | 13-DEC-11:10 | 518.74 | 13-DEC-15:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.348283E+11 | 0.876539E+10 | 6173.66 | 0.245232E+11 | 0.103051E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.278826E+09 | 68601664.94 | 133.81 | 0.199418E+09 | 79408085.68 | 0.00 | 0.26 | 0.00 | 1507.74 | 1160.70 | 379.23 | 367.85 | 0.00 | |||||||
| Maximum of Months | 0.574492E+10 | 0.144948E+10 | 744.00 | 0.402154E+10 | 0.178412E+10 | 0.00 | 0.63 | 0.19 | 3650.95 | 2774.13 | 1160.96 | 1028.53 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.817823E+09 | 0.201565E+09 | 163.67 | 0.694776E+09 | 0.123046E+09 | 0.00 | 1.00 | 17-JAN-09:02 | 0.00 | 01-JAN-00:10 | 7932.89 | 31-JAN-09:02 | 6279.63 | 03-JAN-09:02 | 2879.34 | 31-JAN-09:02 | 1630.12 | 18-JAN-09:02 | 0.00 | 01-JAN-00:10 |
| February | 0.985661E+09 | 0.240132E+09 | 152.50 | 0.809005E+09 | 0.176656E+09 | 0.00 | 1.00 | 01-FEB-09:02 | 0.00 | 01-FEB-00:10 | 7882.57 | 27-FEB-08:62 | 6340.99 | 10-FEB-09:02 | 2645.97 | 21-FEB-09:02 | 1630.12 | 28-FEB-09:02 | 0.00 | 01-FEB-00:10 |
| March | 0.110667E+10 | 0.271461E+09 | 179.97 | 0.902918E+09 | 0.203753E+09 | 0.00 | 1.00 | 01-MAR-09:02 | 0.00 | 01-MAR-00:10 | 7977.62 | 07-MAR-09:02 | 6302.78 | 01-MAR-09:02 | 3004.70 | 07-MAR-09:02 | 1630.12 | 31-MAR-08:62 | 0.00 | 01-MAR-00:10 |
| April | 0.155402E+10 | 0.384597E+09 | 180.66 | 0.127703E+10 | 0.276988E+09 | 0.00 | 1.00 | 04-APR-08:62 | 0.00 | 01-APR-00:10 | 8251.86 | 28-APR-07:03 | 7067.21 | 17-APR-08:62 | 3598.22 | 28-APR-07:03 | 1647.26 | 28-APR-08:62 | 0.00 | 01-APR-00:10 |
| May | 0.316823E+10 | 0.787721E+09 | 263.70 | 0.238894E+10 | 0.779289E+09 | 0.00 | 1.00 | 01-MAY-07:02 | 0.00 | 01-MAY-00:10 | 8360.27 | 23-MAY-07:02 | 5657.15 | 12-MAY-07:02 | 4495.19 | 24-MAY-07:05 | 1740.37 | 16-MAY-08:62 | 0.00 | 01-MAY-00:10 |
| June | 0.344098E+10 | 0.858474E+09 | 294.02 | 0.257013E+10 | 0.870847E+09 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 8356.80 | 30-JUN-07:02 | 5802.20 | 07-JUN-07:02 | 4243.80 | 29-JUN-07:05 | 1786.96 | 28-JUN-08:15 | 0.00 | 01-JUN-00:10 |
| July | 0.371697E+10 | 0.915880E+09 | 367.24 | 0.265903E+10 | 0.105795E+10 | 0.00 | 1.00 | 03-JUL-06:03 | 0.00 | 01-JUL-00:10 | 8358.89 | 14-JUL-07:02 | 5294.60 | 10-JUL-08:62 | 4182.84 | 13-JUL-07:03 | 1791.28 | 19-JUL-08:15 | 0.00 | 01-JUL-00:10 |
| August | 0.426128E+10 | 0.104374E+10 | 383.99 | 0.311597E+10 | 0.114531E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 8361.32 | 28-AUG-06:03 | 5327.19 | 21-AUG-08:62 | 4242.07 | 18-AUG-07:05 | 1770.15 | 22-AUG-08:15 | 0.00 | 01-AUG-00:10 |
| September | 0.366194E+10 | 0.875970E+09 | 352.14 | 0.264647E+10 | 0.101547E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 8361.87 | 05-SEP-06:03 | 5523.87 | 22-SEP-07:02 | 3989.34 | 27-SEP-07:03 | 1751.72 | 01-SEP-08:62 | 0.00 | 01-SEP-00:10 |
| October | 0.341357E+10 | 0.826986E+09 | 315.09 | 0.267407E+10 | 0.739504E+09 | 0.00 | 1.00 | 02-OCT-07:02 | 0.00 | 01-OCT-00:10 | 8361.87 | 23-OCT-06:02 | 7507.31 | 26-OCT-07:02 | 4654.69 | 25-OCT-07:05 | 1723.09 | 06-OCT-08:15 | 0.00 | 01-OCT-00:10 |
| November | 0.195543E+10 | 0.474014E+09 | 192.82 | 0.165210E+10 | 0.303339E+09 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 8353.67 | 02-NOV-07:02 | 7238.40 | 17-NOV-09:02 | 3923.42 | 02-NOV-07:03 | 1637.71 | 07-NOV-09:04 | 0.00 | 01-NOV-00:10 |
| December | 0.121280E+10 | 0.295654E+09 | 173.13 | 0.101426E+10 | 0.198543E+09 | 0.00 | 1.00 | 01-DEC-09:02 | 0.00 | 01-DEC-00:10 | 8217.59 | 15-DEC-08:62 | 7218.86 | 01-DEC-09:02 | 3461.43 | 15-DEC-08:62 | 1629.99 | 11-DEC-09:04 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.292954E+11 | 0.717619E+10 | 3018.93 | 0.224047E+11 | 0.689069E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.817823E+09 | 0.201565E+09 | 152.50 | 0.694776E+09 | 0.123046E+09 | 0.00 | 1.00 | 0.00 | 7882.57 | 5294.60 | 2645.97 | 1629.99 | 0.00 | |||||||
| Maximum of Months | 0.426128E+10 | 0.104374E+10 | 383.99 | 0.311597E+10 | 0.114531E+10 | 0.00 | 1.00 | 0.00 | 8361.87 | 7507.31 | 4654.69 | 1791.28 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.259348E+09 | 63794463.82 | 130.50 | 0.184707E+09 | 74640972.25 | 0.00 | 0.25 | 19-JAN-12:00 | 0.00 | 01-JAN-06:03 | 1399.34 | 19-JAN-12:00 | 997.92 | 02-JAN-17:10 | 488.74 | 19-JAN-10:50 | 346.01 | 19-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.341050E+09 | 84350372.83 | 164.17 | 0.242871E+09 | 98178655.24 | 0.00 | 0.24 | 02-FEB-13:00 | 0.00 | 01-FEB-02:70 | 1330.44 | 02-FEB-13:00 | 983.08 | 02-FEB-13:00 | 389.45 | 24-FEB-11:10 | 346.70 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.603868E+09 | 0.149695E+09 | 251.22 | 0.430953E+09 | 0.172914E+09 | 0.00 | 0.30 | 30-MAR-13:00 | 0.00 | 01-MAR-02:70 | 1667.67 | 30-MAR-13:00 | 1245.96 | 30-MAR-13:00 | 565.33 | 07-MAR-17:03 | 439.19 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.158650E+10 | 0.398291E+09 | 536.42 | 0.117886E+10 | 0.407633E+09 | 0.00 | 0.42 | 29-APR-16:03 | 0.00 | 01-APR-15:50 | 2365.50 | 29-APR-16:03 | 1676.04 | 28-APR-16:10 | 712.97 | 29-APR-16:03 | 611.15 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.449154E+10 | 0.113530E+10 | 744.00 | 0.317334E+10 | 0.131821E+10 | 0.00 | 0.46 | 26-MAY-11:00 | 0.10 | 01-MAY-00:10 | 2622.94 | 26-MAY-11:00 | 1967.49 | 25-MAY-17:05 | 904.53 | 26-MAY-11:00 | 683.90 | 25-MAY-14:10 | 0.00 | 01-MAY-00:10 |
| June | 0.482650E+10 | 0.123021E+10 | 720.00 | 0.345282E+10 | 0.137368E+10 | 0.00 | 0.51 | 28-JUN-17:30 | 0.10 | 07-JUN-01:50 | 2867.86 | 28-JUN-18:00 | 2154.34 | 28-JUN-17:30 | 918.02 | 19-JUN-08:40 | 768.93 | 28-JUN-16:02 | 0.00 | 01-JUN-00:10 |
| July | 0.572107E+10 | 0.144650E+10 | 744.00 | 0.392054E+10 | 0.180053E+10 | 0.00 | 0.58 | 19-JUL-13:00 | 0.20 | 15-JUL-04:00 | 3207.30 | 03-JUL-16:40 | 2462.46 | 19-JUL-13:00 | 1059.83 | 03-JUL-16:30 | 873.03 | 19-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.576603E+10 | 0.145038E+10 | 744.00 | 0.403661E+10 | 0.172942E+10 | 0.00 | 0.58 | 03-AUG-16:02 | 0.18 | 17-AUG-02:70 | 3184.17 | 03-AUG-16:02 | 2522.29 | 03-AUG-16:03 | 1096.75 | 10-AUG-20:20 | 891.43 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.509141E+10 | 0.126114E+10 | 720.00 | 0.348934E+10 | 0.160207E+10 | 0.00 | 0.61 | 10-SEP-12:00 | 0.18 | 28-SEP-04:00 | 3432.22 | 10-SEP-10:30 | 2474.70 | 09-SEP-17:00 | 1049.42 | 18-SEP-16:02 | 939.80 | 10-SEP-12:00 | 0.00 | 01-SEP-00:10 |
| October | 0.412384E+10 | 0.102544E+10 | 695.78 | 0.294133E+10 | 0.118252E+10 | 0.00 | 0.56 | 08-OCT-14:00 | 0.00 | 17-OCT-05:15 | 3185.99 | 08-OCT-14:00 | 2190.66 | 08-OCT-14:00 | 1163.92 | 06-OCT-09:00 | 848.91 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.142273E+10 | 0.352174E+09 | 473.25 | 0.105495E+10 | 0.367775E+09 | 0.00 | 0.39 | 02-NOV-15:10 | 0.00 | 05-NOV-05:03 | 2213.43 | 02-NOV-15:10 | 1587.54 | 02-NOV-16:03 | 721.60 | 07-NOV-13:40 | 570.57 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.770815E+09 | 0.189293E+09 | 238.08 | 0.540812E+09 | 0.230002E+09 | 0.00 | 0.33 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 | 1816.46 | 16-DEC-13:00 | 1332.97 | 16-DEC-13:00 | 661.87 | 13-DEC-11:10 | 464.18 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.350047E+11 | 0.878657E+10 | 6161.43 | 0.246471E+11 | 0.103576E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.259348E+09 | 63794463.82 | 130.50 | 0.184707E+09 | 74640972.25 | 0.00 | 0.24 | 0.00 | 1330.44 | 983.08 | 389.45 | 346.01 | 0.00 | |||||||
| Maximum of Months | 0.576603E+10 | 0.145038E+10 | 744.00 | 0.403661E+10 | 0.180053E+10 | 0.00 | 0.61 | 0.20 | 3432.22 | 2522.29 | 1163.92 | 939.80 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.249983E+09 | 61451220.61 | 139.76 | 0.176848E+09 | 73134605.12 | 0.00 | 0.22 | 02-JAN-17:10 | 0.00 | 01-JAN-06:03 | 1092.53 | 19-JAN-17:10 | 942.02 | 02-JAN-17:10 | 377.47 | 19-JAN-12:00 | 272.49 | 02-JAN-17:10 | 0.00 | 01-JAN-00:10 |
| February | 0.342836E+09 | 84655894.66 | 187.42 | 0.242787E+09 | 0.100048E+09 | 0.00 | 0.23 | 02-FEB-13:00 | 0.00 | 01-FEB-06:05 | 1146.35 | 02-FEB-13:00 | 847.53 | 25-FEB-17:10 | 341.50 | 24-FEB-13:00 | 298.96 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.573930E+09 | 0.142150E+09 | 281.85 | 0.406810E+09 | 0.167120E+09 | 0.00 | 0.28 | 30-MAR-13:00 | 0.00 | 01-MAR-06:40 | 1422.24 | 28-MAR-16:10 | 1020.99 | 30-MAR-13:00 | 514.86 | 07-MAR-17:03 | 367.33 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.150397E+10 | 0.376713E+09 | 588.25 | 0.110833E+10 | 0.395642E+09 | 0.00 | 0.39 | 29-APR-16:03 | 0.00 | 01-APR-17:00 | 1990.23 | 29-APR-16:03 | 1441.63 | 28-APR-16:10 | 601.37 | 29-APR-16:03 | 525.65 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.396078E+10 | 0.100016E+10 | 744.00 | 0.277278E+10 | 0.118799E+10 | 0.00 | 0.44 | 25-MAY-17:05 | 0.13 | 01-MAY-00:10 | 2197.04 | 26-MAY-11:00 | 1687.36 | 25-MAY-17:20 | 771.94 | 26-MAY-11:00 | 589.68 | 25-MAY-17:00 | 0.00 | 01-MAY-00:10 |
| June | 0.423580E+10 | 0.107834E+10 | 720.00 | 0.298460E+10 | 0.125120E+10 | 0.00 | 0.49 | 28-JUN-17:40 | 0.13 | 07-JUN-05:10 | 2463.95 | 28-JUN-18:00 | 1829.34 | 28-JUN-17:40 | 766.75 | 29-JUN-17:10 | 662.11 | 28-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.495491E+10 | 0.125233E+10 | 744.00 | 0.333748E+10 | 0.161743E+10 | 0.00 | 0.53 | 22-JUL-16:40 | 0.22 | 15-JUL-04:00 | 2701.64 | 03-JUL-16:40 | 1937.75 | 19-JUL-17:00 | 894.75 | 03-JUL-16:30 | 734.11 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.493718E+10 | 0.124272E+10 | 744.00 | 0.340546E+10 | 0.153172E+10 | 0.00 | 0.53 | 03-AUG-16:02 | 0.20 | 17-AUG-02:70 | 2642.00 | 17-AUG-16:02 | 2043.41 | 03-AUG-17:00 | 890.65 | 10-AUG-20:20 | 736.21 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.440452E+10 | 0.109115E+10 | 720.00 | 0.298240E+10 | 0.142212E+10 | 0.00 | 0.57 | 09-SEP-17:10 | 0.20 | 22-SEP-03:00 | 2807.07 | 09-SEP-17:10 | 2070.70 | 09-SEP-17:04 | 895.19 | 18-SEP-16:02 | 795.07 | 09-SEP-17:10 | 0.00 | 01-SEP-00:10 |
| October | 0.356978E+10 | 0.888543E+09 | 710.25 | 0.252736E+10 | 0.104242E+10 | 0.00 | 0.51 | 08-OCT-16:03 | 0.00 | 17-OCT-05:40 | 2612.59 | 08-OCT-16:03 | 1788.65 | 08-OCT-16:03 | 964.17 | 24-OCT-13:00 | 690.00 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.132838E+10 | 0.328765E+09 | 513.40 | 0.983035E+09 | 0.345346E+09 | 0.00 | 0.38 | 02-NOV-16:03 | 0.00 | 05-NOV-05:03 | 1899.71 | 02-NOV-16:03 | 1353.38 | 02-NOV-16:03 | 607.57 | 01-NOV-12:00 | 485.23 | 02-NOV-16:03 | 0.00 | 01-NOV-00:10 |
| December | 0.749357E+09 | 0.183799E+09 | 264.17 | 0.526513E+09 | 0.222844E+09 | 0.00 | 0.31 | 13-DEC-14:00 | 0.00 | 01-DEC-01:30 | 1562.63 | 13-DEC-13:50 | 1172.32 | 15-DEC-17:04 | 599.99 | 13-DEC-11:10 | 405.52 | 13-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.308114E+11 | 0.773078E+10 | 6357.10 | 0.214544E+11 | 0.935701E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.249983E+09 | 61451220.61 | 139.76 | 0.176848E+09 | 73134605.12 | 0.00 | 0.22 | 0.00 | 1092.53 | 847.53 | 341.50 | 272.49 | 0.00 | |||||||
| Maximum of Months | 0.495491E+10 | 0.125233E+10 | 744.00 | 0.340546E+10 | 0.161743E+10 | 0.00 | 0.57 | 0.22 | 2807.07 | 2070.70 | 964.17 | 795.07 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.248979E+09 | 61205182.79 | 139.60 | 0.176122E+09 | 72857421.22 | 0.00 | 0.22 | 02-JAN-17:10 | 0.00 | 01-JAN-06:03 | 1085.97 | 19-JAN-17:10 | 940.18 | 02-JAN-17:10 | 378.34 | 19-JAN-12:00 | 271.98 | 02-JAN-17:10 | 0.00 | 01-JAN-00:10 |
| February | 0.340592E+09 | 84105125.78 | 186.56 | 0.241086E+09 | 99505689.21 | 0.00 | 0.23 | 02-FEB-13:00 | 0.00 | 01-FEB-06:05 | 1146.25 | 02-FEB-13:00 | 839.87 | 02-FEB-13:00 | 341.76 | 24-FEB-13:00 | 298.93 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.575479E+09 | 0.142525E+09 | 282.05 | 0.407952E+09 | 0.167527E+09 | 0.00 | 0.28 | 30-MAR-13:00 | 0.00 | 01-MAR-06:40 | 1424.91 | 28-MAR-16:10 | 1026.40 | 30-MAR-13:00 | 514.92 | 07-MAR-17:03 | 368.89 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.150548E+10 | 0.377092E+09 | 588.25 | 0.110958E+10 | 0.395904E+09 | 0.00 | 0.39 | 29-APR-16:03 | 0.00 | 01-APR-17:00 | 1986.78 | 29-APR-16:03 | 1437.81 | 28-APR-16:10 | 600.41 | 29-APR-16:03 | 524.40 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.396530E+10 | 0.100125E+10 | 744.00 | 0.277647E+10 | 0.118882E+10 | 0.00 | 0.44 | 25-MAY-17:05 | 0.13 | 01-MAY-00:10 | 2198.75 | 26-MAY-11:00 | 1685.09 | 25-MAY-17:20 | 772.29 | 26-MAY-11:00 | 588.98 | 25-MAY-17:00 | 0.00 | 01-MAY-00:10 |
| June | 0.423875E+10 | 0.107903E+10 | 720.00 | 0.298699E+10 | 0.125176E+10 | 0.00 | 0.49 | 28-JUN-17:30 | 0.13 | 07-JUN-05:10 | 2459.62 | 28-JUN-18:00 | 1825.98 | 28-JUN-17:40 | 766.80 | 29-JUN-17:10 | 661.09 | 28-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.495954E+10 | 0.125342E+10 | 744.00 | 0.334130E+10 | 0.161824E+10 | 0.00 | 0.53 | 22-JUL-16:30 | 0.22 | 15-JUL-04:00 | 2699.80 | 03-JUL-16:40 | 1937.95 | 19-JUL-17:00 | 894.35 | 03-JUL-16:30 | 734.08 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.493847E+10 | 0.124298E+10 | 744.00 | 0.340644E+10 | 0.153203E+10 | 0.00 | 0.53 | 03-AUG-16:02 | 0.20 | 17-AUG-02:70 | 2639.54 | 17-AUG-16:02 | 2040.75 | 03-AUG-16:40 | 890.79 | 10-AUG-20:20 | 735.60 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.440484E+10 | 0.109118E+10 | 720.00 | 0.298253E+10 | 0.142230E+10 | 0.00 | 0.57 | 09-SEP-17:10 | 0.20 | 22-SEP-03:00 | 2801.58 | 09-SEP-17:10 | 2065.96 | 09-SEP-17:04 | 894.31 | 18-SEP-16:02 | 793.56 | 09-SEP-17:10 | 0.00 | 01-SEP-00:10 |
| October | 0.356951E+10 | 0.888441E+09 | 710.08 | 0.252702E+10 | 0.104250E+10 | 0.00 | 0.51 | 08-OCT-16:03 | 0.00 | 17-OCT-05:40 | 2607.82 | 08-OCT-16:03 | 1784.84 | 08-OCT-16:03 | 964.49 | 24-OCT-13:00 | 690.00 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.132971E+10 | 0.329101E+09 | 514.13 | 0.984220E+09 | 0.345490E+09 | 0.00 | 0.37 | 02-NOV-16:03 | 0.00 | 05-NOV-05:03 | 1896.00 | 02-NOV-16:03 | 1350.58 | 02-NOV-16:03 | 607.63 | 01-NOV-12:00 | 484.31 | 02-NOV-16:03 | 0.00 | 01-NOV-00:10 |
| December | 0.747010E+09 | 0.183220E+09 | 263.42 | 0.524584E+09 | 0.222426E+09 | 0.00 | 0.31 | 13-DEC-14:00 | 0.00 | 01-DEC-01:30 | 1560.58 | 13-DEC-13:50 | 1164.83 | 15-DEC-17:04 | 599.86 | 13-DEC-11:10 | 404.92 | 13-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.308237E+11 | 0.773355E+10 | 6356.09 | 0.214643E+11 | 0.935937E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.248979E+09 | 61205182.79 | 139.60 | 0.176122E+09 | 72857421.22 | 0.00 | 0.22 | 0.00 | 1085.97 | 839.87 | 341.76 | 271.98 | 0.00 | |||||||
| Maximum of Months | 0.495954E+10 | 0.125342E+10 | 744.00 | 0.340644E+10 | 0.161824E+10 | 0.00 | 0.57 | 0.22 | 2801.58 | 2065.96 | 964.49 | 793.56 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.859598E+09 | 0.212928E+09 | 369.27 | 0.694701E+09 | 0.164897E+09 | 0.00 | 0.42 | 01-JAN-14:00 | 0.00 | 03-JAN-01:40 | 2219.10 | 19-JAN-14:00 | 1953.81 | 01-JAN-14:00 | 621.89 | 19-JAN-10:40 | 540.58 | 01-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.926054E+09 | 0.228671E+09 | 357.96 | 0.723289E+09 | 0.202765E+09 | 0.00 | 0.38 | 02-FEB-13:00 | 0.00 | 01-FEB-06:05 | 1979.38 | 02-FEB-13:00 | 1603.24 | 02-FEB-13:30 | 469.57 | 24-FEB-11:00 | 509.79 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.981713E+09 | 0.243780E+09 | 392.58 | 0.748794E+09 | 0.232919E+09 | 0.00 | 0.34 | 06-MAR-13:00 | 0.00 | 01-MAR-06:40 | 1795.84 | 06-MAR-13:00 | 1369.74 | 05-MAR-14:00 | 589.03 | 07-MAR-17:03 | 453.81 | 06-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.182583E+10 | 0.457909E+09 | 634.53 | 0.138878E+10 | 0.437050E+09 | 0.00 | 0.42 | 29-APR-16:03 | 0.00 | 01-APR-18:00 | 2239.62 | 29-APR-16:03 | 1618.90 | 28-APR-15:10 | 644.60 | 29-APR-16:03 | 579.86 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.398890E+10 | 0.100982E+10 | 744.00 | 0.280275E+10 | 0.118614E+10 | 0.00 | 0.42 | 07-MAY-17:10 | 0.13 | 01-MAY-00:10 | 2162.62 | 26-MAY-11:00 | 1726.31 | 07-MAY-17:17 | 758.20 | 26-MAY-11:00 | 592.27 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.415071E+10 | 0.105988E+10 | 720.00 | 0.291769E+10 | 0.123302E+10 | 0.00 | 0.45 | 17-JUN-16:40 | 0.12 | 07-JUN-01:50 | 2373.17 | 17-JUN-16:40 | 1783.34 | 10-JUN-16:40 | 738.75 | 29-JUN-17:20 | 645.10 | 17-JUN-16:40 | 0.00 | 01-JUN-00:10 |
| July | 0.493219E+10 | 0.125021E+10 | 744.00 | 0.332126E+10 | 0.161093E+10 | 0.00 | 0.52 | 22-JUL-16:10 | 0.21 | 15-JUL-04:00 | 2702.03 | 22-JUL-16:10 | 2001.40 | 22-JUL-16:09 | 864.25 | 03-JUL-16:30 | 767.47 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.509887E+10 | 0.128648E+10 | 744.00 | 0.355296E+10 | 0.154591E+10 | 0.00 | 0.52 | 03-AUG-16:02 | 0.19 | 17-AUG-02:70 | 2675.45 | 17-AUG-16:02 | 2196.13 | 30-AUG-16:03 | 901.97 | 10-AUG-20:20 | 748.98 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.481644E+10 | 0.119462E+10 | 720.00 | 0.334059E+10 | 0.147585E+10 | 0.00 | 0.60 | 10-SEP-13:40 | 0.20 | 28-SEP-04:00 | 3193.33 | 10-SEP-13:30 | 2315.20 | 10-SEP-15:10 | 930.79 | 18-SEP-14:20 | 886.37 | 10-SEP-13:50 | 0.00 | 01-SEP-00:10 |
| October | 0.441535E+10 | 0.109796E+10 | 735.81 | 0.328236E+10 | 0.113299E+10 | 0.00 | 0.61 | 08-OCT-14:00 | 0.00 | 18-OCT-05:40 | 3323.11 | 08-OCT-14:00 | 2413.22 | 09-OCT-14:00 | 1050.99 | 07-OCT-09:00 | 881.95 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.242598E+10 | 0.602467E+09 | 678.83 | 0.199081E+10 | 0.435170E+09 | 0.00 | 0.51 | 07-NOV-13:30 | 0.00 | 09-NOV-03:10 | 2760.09 | 07-NOV-13:30 | 2037.50 | 02-NOV-15:10 | 800.75 | 29-NOV-12:20 | 689.18 | 07-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.158363E+10 | 0.391622E+09 | 485.69 | 0.127320E+10 | 0.310428E+09 | 0.00 | 0.48 | 16-DEC-13:00 | 0.00 | 03-DEC-23:00 | 2589.49 | 16-DEC-13:00 | 2049.06 | 10-DEC-15:00 | 665.03 | 14-DEC-11:30 | 651.09 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.360052E+11 | 0.903633E+10 | 7326.66 | 0.260372E+11 | 0.996806E+10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.859598E+09 | 0.212928E+09 | 357.96 | 0.694701E+09 | 0.164897E+09 | 0.00 | 0.34 | 0.00 | 1795.84 | 1369.74 | 469.57 | 453.81 | 0.00 | |||||||
| Maximum of Months | 0.509887E+10 | 0.128648E+10 | 744.00 | 0.355296E+10 | 0.161093E+10 | 0.00 | 0.61 | 0.21 | 3323.11 | 2413.22 | 1050.99 | 886.37 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.946748E+09 | 0.234566E+09 | 387.36 | 0.772800E+09 | 0.173948E+09 | 0.00 | 0.44 | 01-JAN-14:00 | 0.00 | 03-JAN-02:40 | 2326.76 | 01-JAN-14:00 | 2118.46 | 01-JAN-14:00 | 632.81 | 19-JAN-10:40 | 580.36 | 01-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.995108E+09 | 0.245654E+09 | 371.50 | 0.781801E+09 | 0.213307E+09 | 0.00 | 0.39 | 02-FEB-13:00 | 0.00 | 01-FEB-06:05 | 2029.78 | 02-FEB-13:00 | 1665.14 | 27-FEB-15:10 | 478.87 | 24-FEB-11:00 | 522.46 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.107655E+10 | 0.267221E+09 | 410.11 | 0.828349E+09 | 0.248199E+09 | 0.00 | 0.35 | 06-MAR-13:00 | 0.00 | 01-MAR-06:40 | 1868.06 | 07-MAR-11:30 | 1440.57 | 05-MAR-14:00 | 606.98 | 07-MAR-17:03 | 469.89 | 06-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.199266E+10 | 0.499077E+09 | 646.40 | 0.152871E+10 | 0.463953E+09 | 0.00 | 0.44 | 29-APR-16:03 | 0.00 | 01-APR-18:30 | 2366.05 | 29-APR-16:03 | 1706.21 | 29-APR-16:07 | 659.99 | 29-APR-16:03 | 611.44 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.431266E+10 | 0.108974E+10 | 744.00 | 0.307694E+10 | 0.123572E+10 | 0.00 | 0.44 | 07-MAY-17:20 | 0.15 | 01-MAY-00:10 | 2298.53 | 28-MAY-17:10 | 1873.70 | 07-MAY-17:20 | 766.70 | 26-MAY-11:00 | 632.72 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.447781E+10 | 0.114115E+10 | 720.00 | 0.319855E+10 | 0.127926E+10 | 0.00 | 0.47 | 17-JUN-16:40 | 0.14 | 07-JUN-01:50 | 2513.72 | 17-JUN-16:40 | 1906.84 | 10-JUN-16:40 | 753.14 | 29-JUN-17:20 | 681.76 | 17-JUN-16:40 | 0.00 | 01-JUN-00:10 |
| July | 0.531405E+10 | 0.134444E+10 | 744.00 | 0.364761E+10 | 0.166644E+10 | 0.00 | 0.55 | 22-JUL-16:10 | 0.23 | 15-JUL-04:00 | 2857.41 | 23-JUL-17:10 | 2143.15 | 22-JUL-16:03 | 879.48 | 02-JUL-09:00 | 808.28 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.546533E+10 | 0.137603E+10 | 744.00 | 0.386959E+10 | 0.159574E+10 | 0.00 | 0.53 | 27-AUG-16:10 | 0.21 | 17-AUG-02:70 | 2791.63 | 13-AUG-15:10 | 2283.82 | 30-AUG-16:10 | 930.80 | 10-AUG-20:20 | 772.55 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.517084E+10 | 0.128002E+10 | 720.00 | 0.364437E+10 | 0.152647E+10 | 0.00 | 0.63 | 10-SEP-13:50 | 0.22 | 28-SEP-04:00 | 3378.27 | 10-SEP-13:30 | 2486.07 | 10-SEP-15:10 | 944.45 | 18-SEP-14:20 | 935.10 | 10-SEP-13:50 | 0.00 | 01-SEP-00:10 |
| October | 0.474733E+10 | 0.117799E+10 | 741.67 | 0.357578E+10 | 0.117155E+10 | 0.00 | 0.64 | 08-OCT-14:00 | 0.00 | 28-OCT-04:30 | 3511.60 | 08-OCT-14:00 | 2602.95 | 09-OCT-14:00 | 1069.49 | 07-OCT-09:00 | 928.77 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.261678E+10 | 0.649216E+09 | 694.99 | 0.216426E+10 | 0.452517E+09 | 0.00 | 0.52 | 07-NOV-13:40 | 0.00 | 09-NOV-04:30 | 2860.95 | 07-NOV-13:40 | 2125.16 | 07-NOV-13:40 | 814.76 | 29-NOV-12:20 | 713.43 | 07-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.170819E+10 | 0.422067E+09 | 497.66 | 0.138372E+10 | 0.324474E+09 | 0.00 | 0.50 | 16-DEC-13:00 | 0.00 | 03-DEC-23:10 | 2714.16 | 16-DEC-13:00 | 2169.89 | 10-DEC-15:00 | 685.54 | 13-DEC-11:00 | 680.98 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.388240E+11 | 0.972718E+10 | 7421.68 | 0.284725E+11 | 0.103516E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.946748E+09 | 0.234566E+09 | 371.50 | 0.772800E+09 | 0.173948E+09 | 0.00 | 0.35 | 0.00 | 1868.06 | 1440.57 | 478.87 | 469.89 | 0.00 | |||||||
| Maximum of Months | 0.546533E+10 | 0.137603E+10 | 744.00 | 0.386959E+10 | 0.166644E+10 | 0.00 | 0.64 | 0.23 | 3511.60 | 2602.95 | 1069.49 | 935.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.181324E+10 | 0.447072E+09 | 280.14 | 0.144431E+10 | 0.368935E+09 | 0.00 | 0.46 | 19-JAN-15:30 | 0.00 | 01-JAN-06:03 | 6387.11 | 19-JAN-15:30 | 5051.71 | 01-JAN-15:20 | 1564.37 | 19-JAN-10:40 | 1531.05 | 19-JAN-15:30 | 0.00 | 01-JAN-00:10 |
| February | 0.260590E+10 | 0.643292E+09 | 362.94 | 0.208430E+10 | 0.521596E+09 | 0.00 | 0.43 | 27-FEB-16:10 | 0.00 | 01-FEB-06:05 | 5777.38 | 27-FEB-16:10 | 4895.91 | 27-FEB-16:10 | 1182.83 | 02-FEB-11:00 | 1417.38 | 27-FEB-16:10 | 0.00 | 01-FEB-00:10 |
| March | 0.307050E+10 | 0.761862E+09 | 415.53 | 0.242419E+10 | 0.646309E+09 | 0.00 | 0.42 | 06-MAR-16:10 | 0.00 | 01-MAR-06:50 | 5791.45 | 06-MAR-16:10 | 4527.50 | 06-MAR-16:10 | 1769.77 | 07-MAR-16:30 | 1420.42 | 06-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.558693E+10 | 0.140013E+10 | 649.56 | 0.439938E+10 | 0.118755E+10 | 0.00 | 0.53 | 29-APR-16:03 | 0.00 | 01-APR-18:20 | 7417.45 | 29-APR-16:03 | 5415.68 | 29-APR-16:10 | 2002.24 | 29-APR-16:03 | 1891.62 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.106227E+11 | 0.269363E+10 | 744.00 | 0.761560E+10 | 0.300712E+10 | 0.00 | 0.50 | 28-MAY-16:30 | 0.13 | 01-MAY-00:10 | 6737.16 | 28-MAY-17:10 | 5488.72 | 10-MAY-16:30 | 2025.90 | 26-MAY-11:00 | 1823.64 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.107688E+11 | 0.275976E+10 | 720.00 | 0.777372E+10 | 0.299510E+10 | 0.00 | 0.53 | 17-JUN-16:30 | 0.10 | 07-JUN-01:50 | 7185.60 | 17-JUN-16:30 | 5661.45 | 10-JUN-16:40 | 1905.68 | 29-JUN-15:40 | 1937.95 | 17-JUN-16:30 | 0.00 | 01-JUN-00:10 |
| July | 0.121326E+11 | 0.308817E+10 | 744.00 | 0.825787E+10 | 0.387470E+10 | 0.00 | 0.56 | 22-JUL-16:30 | 0.17 | 12-JUL-04:00 | 7466.57 | 22-JUL-16:30 | 5753.33 | 22-JUL-16:30 | 2440.94 | 03-JUL-16:13 | 2107.53 | 22-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 0.119572E+11 | 0.303220E+10 | 744.00 | 0.827356E+10 | 0.368365E+10 | 0.00 | 0.57 | 03-AUG-16:02 | 0.13 | 17-AUG-03:00 | 7574.48 | 03-AUG-16:02 | 6258.99 | 30-AUG-16:03 | 2538.51 | 10-AUG-20:20 | 2126.75 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.109940E+11 | 0.274090E+10 | 720.00 | 0.751405E+10 | 0.347995E+10 | 0.00 | 0.63 | 09-SEP-17:00 | 0.14 | 28-SEP-04:00 | 8487.94 | 09-SEP-17:00 | 6475.54 | 09-SEP-17:00 | 2665.85 | 18-SEP-14:20 | 2394.62 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.988028E+10 | 0.246740E+10 | 696.50 | 0.719956E+10 | 0.268072E+10 | 0.00 | 0.64 | 08-OCT-15:30 | 0.00 | 17-OCT-05:03 | 9127.96 | 08-OCT-15:30 | 6504.66 | 08-OCT-15:30 | 2902.20 | 24-OCT-13:30 | 2359.76 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.487225E+10 | 0.121288E+10 | 576.13 | 0.395117E+10 | 0.921080E+09 | 0.00 | 0.52 | 02-NOV-15:10 | 0.00 | 05-NOV-05:03 | 7229.30 | 02-NOV-15:10 | 5593.02 | 02-NOV-15:10 | 2018.19 | 29-NOV-12:20 | 1842.26 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.319784E+10 | 0.791746E+09 | 387.13 | 0.254315E+10 | 0.654690E+09 | 0.00 | 0.47 | 16-DEC-13:30 | 0.00 | 01-DEC-01:40 | 6478.68 | 16-DEC-13:30 | 5521.18 | 10-DEC-15:10 | 1635.77 | 14-DEC-11:30 | 1619.46 | 15-DEC-15:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.875023E+11 | 0.220390E+11 | 7039.93 | 0.634809E+11 | 0.240214E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.181324E+10 | 0.447072E+09 | 280.14 | 0.144431E+10 | 0.368935E+09 | 0.00 | 0.42 | 0.00 | 5777.38 | 4527.50 | 1182.83 | 1417.38 | 0.00 | |||||||
| Maximum of Months | 0.121326E+11 | 0.308817E+10 | 744.00 | 0.827356E+10 | 0.387470E+10 | 0.00 | 0.64 | 0.17 | 9127.96 | 6504.66 | 2902.20 | 2394.62 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.782390E+09 | 0.191920E+09 | 151.72 | 0.558496E+09 | 0.223894E+09 | 0.00 | 0.29 | 19-JAN-16:10 | 0.00 | 01-JAN-04:50 | 3847.86 | 19-JAN-16:10 | 2753.68 | 19-JAN-16:10 | 1177.80 | 31-JAN-17:10 | 934.39 | 19-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.134508E+10 | 0.331957E+09 | 245.26 | 0.994892E+09 | 0.350187E+09 | 0.00 | 0.30 | 27-FEB-17:10 | 0.00 | 01-FEB-06:05 | 3928.86 | 27-FEB-17:03 | 3182.84 | 25-FEB-17:10 | 982.10 | 28-FEB-17:20 | 955.22 | 27-FEB-17:10 | 0.00 | 01-FEB-00:10 |
| March | 0.218543E+10 | 0.541297E+09 | 331.18 | 0.163435E+10 | 0.551089E+09 | 0.00 | 0.33 | 26-MAR-16:10 | 0.00 | 01-MAR-03:40 | 4418.10 | 28-MAR-16:10 | 3546.37 | 26-MAR-16:20 | 1606.03 | 07-MAR-16:30 | 1087.14 | 26-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.493133E+10 | 0.123500E+10 | 626.47 | 0.380752E+10 | 0.112381E+10 | 0.00 | 0.51 | 29-APR-16:03 | 0.00 | 01-APR-17:40 | 6817.93 | 29-APR-16:03 | 4999.07 | 28-APR-16:10 | 1904.44 | 29-APR-16:03 | 1742.82 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.105708E+11 | 0.267512E+10 | 744.00 | 0.756424E+10 | 0.300655E+10 | 0.00 | 0.51 | 28-MAY-17:10 | 0.13 | 01-MAY-00:10 | 6715.60 | 28-MAY-17:10 | 5419.81 | 10-MAY-16:30 | 2049.43 | 26-MAY-11:00 | 1777.01 | 28-MAY-16:30 | 0.00 | 01-MAY-00:10 |
| June | 0.109368E+11 | 0.279622E+10 | 720.00 | 0.791393E+10 | 0.302289E+10 | 0.00 | 0.56 | 28-JUN-17:30 | 0.10 | 07-JUN-05:10 | 7432.22 | 28-JUN-17:30 | 5754.66 | 28-JUN-17:25 | 1946.74 | 29-JUN-15:40 | 1986.03 | 28-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.121720E+11 | 0.309179E+10 | 744.00 | 0.829220E+10 | 0.387976E+10 | 0.00 | 0.56 | 22-JUL-16:30 | 0.18 | 12-JUL-04:00 | 7572.78 | 03-JUL-16:30 | 5727.53 | 07-JUL-16:30 | 2500.60 | 03-JUL-16:13 | 2029.49 | 22-JUL-16:30 | 0.00 | 01-JUL-00:10 |
| August | 0.116139E+11 | 0.294026E+10 | 744.00 | 0.796851E+10 | 0.364543E+10 | 0.00 | 0.58 | 03-AUG-16:13 | 0.14 | 17-AUG-03:00 | 7508.38 | 03-AUG-16:13 | 5958.25 | 03-AUG-16:30 | 2506.90 | 10-AUG-20:20 | 2096.56 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.101401E+11 | 0.252606E+10 | 720.00 | 0.678376E+10 | 0.335630E+10 | 0.00 | 0.61 | 09-SEP-17:00 | 0.14 | 28-SEP-04:00 | 7896.74 | 09-SEP-17:10 | 5947.43 | 09-SEP-17:00 | 2539.97 | 18-SEP-16:13 | 2231.07 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.813154E+10 | 0.203318E+10 | 671.05 | 0.566376E+10 | 0.246778E+10 | 0.00 | 0.55 | 08-OCT-16:03 | 0.00 | 17-OCT-05:03 | 7498.82 | 08-OCT-16:03 | 5124.11 | 08-OCT-16:10 | 2625.84 | 24-OCT-13:40 | 1919.19 | 08-OCT-16:03 | 0.00 | 01-OCT-00:10 |
| November | 0.276302E+10 | 0.685855E+09 | 431.70 | 0.202323E+10 | 0.739786E+09 | 0.00 | 0.40 | 02-NOV-16:03 | 0.00 | 05-NOV-05:03 | 5364.59 | 02-NOV-16:03 | 3928.14 | 02-NOV-16:03 | 1696.41 | 07-NOV-14:00 | 1368.05 | 02-NOV-16:03 | 0.00 | 01-NOV-00:10 |
| December | 0.166608E+10 | 0.410211E+09 | 241.50 | 0.117372E+10 | 0.492357E+09 | 0.00 | 0.33 | 13-DEC-15:10 | 0.00 | 01-DEC-00:10 | 4371.27 | 14-DEC-16:10 | 3450.13 | 13-DEC-16:10 | 1442.91 | 13-DEC-11:10 | 1145.17 | 13-DEC-15:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.772384E+11 | 0.194589E+11 | 6370.89 | 0.543786E+11 | 0.228598E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.782390E+09 | 0.191920E+09 | 151.72 | 0.558496E+09 | 0.223894E+09 | 0.00 | 0.29 | 0.00 | 3847.86 | 2753.68 | 982.10 | 934.39 | 0.00 | |||||||
| Maximum of Months | 0.121720E+11 | 0.309179E+10 | 744.00 | 0.829220E+10 | 0.387976E+10 | 0.00 | 0.61 | 0.18 | 7896.74 | 5958.25 | 2625.84 | 2231.07 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.173990E+10 | 0.428157E+09 | 274.80 | 0.137914E+10 | 0.360755E+09 | 0.00 | 0.46 | 19-JAN-14:00 | 0.00 | 01-JAN-06:03 | 6046.19 | 19-JAN-14:00 | 4863.65 | 01-JAN-14:00 | 1751.75 | 19-JAN-10:40 | 1448.01 | 19-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.252868E+10 | 0.623337E+09 | 365.94 | 0.201817E+10 | 0.510510E+09 | 0.00 | 0.43 | 02-FEB-13:00 | 0.00 | 01-FEB-06:05 | 5513.77 | 02-FEB-13:00 | 4491.42 | 02-FEB-13:30 | 1296.19 | 02-FEB-10:40 | 1409.28 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.314120E+10 | 0.777445E+09 | 418.13 | 0.248161E+10 | 0.659590E+09 | 0.00 | 0.43 | 07-MAR-11:30 | 0.00 | 01-MAR-06:50 | 5614.85 | 07-MAR-11:30 | 4223.00 | 06-MAR-13:00 | 1713.26 | 07-MAR-16:30 | 1358.69 | 07-MAR-11:30 | 0.00 | 01-MAR-00:10 |
| April | 0.557105E+10 | 0.139322E+10 | 654.94 | 0.438574E+10 | 0.118531E+10 | 0.00 | 0.50 | 29-APR-16:03 | 0.00 | 01-APR-18:00 | 6512.76 | 29-APR-16:03 | 4712.02 | 28-APR-15:10 | 1840.94 | 29-APR-16:03 | 1666.09 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.108166E+11 | 0.273270E+10 | 744.00 | 0.777987E+10 | 0.303675E+10 | 0.00 | 0.49 | 25-MAY-14:00 | 0.13 | 01-MAY-00:10 | 6294.01 | 28-MAY-10:00 | 4849.05 | 07-MAY-14:00 | 2175.42 | 27-MAY-08:40 | 1671.20 | 25-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.108903E+11 | 0.278119E+10 | 720.00 | 0.787821E+10 | 0.301210E+10 | 0.00 | 0.51 | 28-JUN-15:10 | 0.10 | 07-JUN-01:50 | 6478.39 | 28-JUN-15:10 | 4986.80 | 10-JUN-16:30 | 1989.34 | 19-JUN-08:40 | 1761.50 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.123305E+11 | 0.312757E+10 | 744.00 | 0.843154E+10 | 0.389892E+10 | 0.00 | 0.57 | 19-JUL-13:00 | 0.18 | 12-JUL-04:00 | 7314.46 | 19-JUL-13:00 | 5610.97 | 19-JUL-13:00 | 2383.22 | 03-JUL-16:13 | 1995.86 | 19-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.119878E+11 | 0.302968E+10 | 744.00 | 0.830213E+10 | 0.368569E+10 | 0.00 | 0.55 | 03-AUG-16:02 | 0.14 | 17-AUG-03:00 | 6908.49 | 17-AUG-16:02 | 5422.14 | 03-AUG-16:10 | 2533.28 | 10-AUG-20:20 | 1930.31 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.109799E+11 | 0.272865E+10 | 720.00 | 0.750515E+10 | 0.347480E+10 | 0.00 | 0.64 | 10-SEP-12:00 | 0.15 | 28-SEP-04:00 | 8208.83 | 10-SEP-12:00 | 5988.26 | 10-SEP-12:00 | 2515.58 | 18-SEP-14:20 | 2257.00 | 10-SEP-12:00 | 0.00 | 01-SEP-00:10 |
| October | 0.982573E+10 | 0.244516E+10 | 697.73 | 0.714864E+10 | 0.267709E+10 | 0.00 | 0.65 | 08-OCT-14:00 | 0.00 | 17-OCT-05:03 | 8627.93 | 08-OCT-14:00 | 6293.24 | 09-OCT-14:00 | 2822.48 | 24-OCT-13:30 | 2270.46 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.486250E+10 | 0.120793E+10 | 584.73 | 0.394331E+10 | 0.919190E+09 | 0.00 | 0.53 | 07-NOV-13:30 | 0.00 | 05-NOV-05:03 | 7037.86 | 07-NOV-13:30 | 5160.86 | 02-NOV-14:10 | 2018.20 | 29-NOV-12:20 | 1747.08 | 07-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.305942E+10 | 0.755931E+09 | 388.91 | 0.241911E+10 | 0.640310E+09 | 0.00 | 0.51 | 16-DEC-13:00 | 0.00 | 01-DEC-01:10 | 6606.43 | 16-DEC-13:00 | 5212.62 | 16-DEC-13:00 | 1678.76 | 16-DEC-09:40 | 1654.39 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.877336E+11 | 0.220310E+11 | 7057.19 | 0.636726E+11 | 0.240610E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.173990E+10 | 0.428157E+09 | 274.80 | 0.137914E+10 | 0.360755E+09 | 0.00 | 0.43 | 0.00 | 5513.77 | 4223.00 | 1296.19 | 1358.69 | 0.00 | |||||||
| Maximum of Months | 0.123305E+11 | 0.312757E+10 | 744.00 | 0.843154E+10 | 0.389892E+10 | 0.00 | 0.65 | 0.18 | 8627.93 | 6293.24 | 2822.48 | 2270.46 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.734534E+09 | 0.180097E+09 | 152.89 | 0.520812E+09 | 0.213722E+09 | 0.00 | 0.28 | 19-JAN-12:00 | 0.00 | 01-JAN-04:50 | 3474.54 | 19-JAN-12:00 | 2402.13 | 19-JAN-12:00 | 1211.85 | 19-JAN-10:40 | 857.78 | 19-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.126598E+10 | 0.312252E+09 | 241.64 | 0.927957E+09 | 0.338023E+09 | 0.00 | 0.29 | 24-FEB-13:00 | 0.00 | 01-FEB-06:05 | 3597.79 | 24-FEB-13:00 | 2673.15 | 24-FEB-13:00 | 1047.80 | 24-FEB-11:00 | 920.60 | 24-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.225008E+10 | 0.555900E+09 | 337.20 | 0.167965E+10 | 0.570426E+09 | 0.00 | 0.35 | 28-MAR-16:10 | 0.00 | 01-MAR-03:20 | 4455.32 | 28-MAR-16:10 | 3289.18 | 26-MAR-14:00 | 1563.90 | 07-MAR-17:03 | 1115.42 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.491844E+10 | 0.122940E+10 | 635.08 | 0.378875E+10 | 0.112969E+10 | 0.00 | 0.47 | 29-APR-16:03 | 0.00 | 01-APR-17:12 | 5926.33 | 29-APR-16:03 | 4221.88 | 28-APR-15:10 | 1740.71 | 29-APR-16:03 | 1520.18 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.107767E+11 | 0.271702E+10 | 744.00 | 0.772862E+10 | 0.304809E+10 | 0.00 | 0.50 | 25-MAY-14:00 | 0.13 | 01-MAY-00:10 | 6231.16 | 26-MAY-11:00 | 4711.41 | 25-MAY-17:10 | 2127.35 | 27-MAY-08:30 | 1653.48 | 25-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.110687E+11 | 0.281962E+10 | 720.00 | 0.801843E+10 | 0.305027E+10 | 0.00 | 0.54 | 28-JUN-18:00 | 0.11 | 07-JUN-05:10 | 6627.55 | 28-JUN-18:00 | 4983.90 | 28-JUN-17:50 | 2061.04 | 19-JUN-08:40 | 1772.94 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.123808E+11 | 0.313343E+10 | 744.00 | 0.846569E+10 | 0.391509E+10 | 0.00 | 0.59 | 19-JUL-13:00 | 0.19 | 12-JUL-04:00 | 7321.80 | 19-JUL-13:00 | 5595.80 | 19-JUL-13:00 | 2449.71 | 03-JUL-16:13 | 1990.92 | 19-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.116579E+11 | 0.294156E+10 | 744.00 | 0.799756E+10 | 0.366031E+10 | 0.00 | 0.56 | 03-AUG-16:02 | 0.14 | 17-AUG-03:00 | 6844.21 | 17-AUG-16:02 | 5303.65 | 03-AUG-16:10 | 2506.42 | 10-AUG-20:20 | 1902.36 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.101397E+11 | 0.251856E+10 | 720.00 | 0.677619E+10 | 0.336346E+10 | 0.00 | 0.58 | 10-SEP-10:30 | 0.14 | 22-SEP-06:00 | 7300.44 | 10-SEP-10:30 | 5141.90 | 09-SEP-17:00 | 2368.98 | 18-SEP-14:20 | 1982.70 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.809135E+10 | 0.201663E+10 | 669.76 | 0.561536E+10 | 0.247599E+10 | 0.00 | 0.54 | 08-OCT-14:00 | 0.00 | 17-OCT-05:03 | 6783.13 | 08-OCT-14:00 | 4524.66 | 08-OCT-14:00 | 2589.69 | 24-OCT-13:00 | 1808.05 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.273692E+10 | 0.677971E+09 | 430.79 | 0.199398E+10 | 0.742938E+09 | 0.00 | 0.38 | 02-NOV-15:10 | 0.00 | 05-NOV-05:00 | 4707.04 | 07-NOV-13:40 | 3319.42 | 02-NOV-15:10 | 1610.30 | 07-NOV-13:40 | 1210.83 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.157350E+10 | 0.386748E+09 | 235.42 | 0.109529E+10 | 0.478206E+09 | 0.00 | 0.32 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 | 3906.04 | 16-DEC-13:00 | 2836.71 | 16-DEC-13:00 | 1461.10 | 13-DEC-11:10 | 998.22 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.775945E+11 | 0.194892E+11 | 6374.78 | 0.546083E+11 | 0.229862E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.734534E+09 | 0.180097E+09 | 152.89 | 0.520812E+09 | 0.213722E+09 | 0.00 | 0.28 | 0.00 | 3474.54 | 2402.13 | 1047.80 | 857.78 | 0.00 | |||||||
| Maximum of Months | 0.123808E+11 | 0.313343E+10 | 744.00 | 0.846569E+10 | 0.391509E+10 | 0.00 | 0.59 | 0.19 | 7321.80 | 5595.80 | 2589.69 | 1990.92 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.744268E+09 | 0.182439E+09 | 162.79 | 0.526898E+09 | 0.217371E+09 | 0.00 | 0.24 | 31-JAN-16:10 | 0.00 | 01-JAN-06:03 | 2701.09 | 31-JAN-16:10 | 2009.64 | 02-JAN-17:10 | 963.14 | 31-JAN-13:00 | 655.18 | 31-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.122279E+10 | 0.301597E+09 | 271.98 | 0.891901E+09 | 0.330887E+09 | 0.00 | 0.26 | 24-FEB-13:00 | 0.00 | 01-FEB-06:05 | 2872.35 | 24-FEB-13:00 | 2163.16 | 25-FEB-17:10 | 873.83 | 02-FEB-22:10 | 738.31 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.200933E+10 | 0.497006E+09 | 373.82 | 0.149201E+10 | 0.517322E+09 | 0.00 | 0.32 | 28-MAR-16:10 | 0.00 | 01-MAR-06:50 | 3619.45 | 28-MAR-16:10 | 2621.89 | 27-MAR-16:05 | 1354.29 | 07-MAR-17:03 | 889.49 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.428869E+10 | 0.107209E+10 | 663.34 | 0.327162E+10 | 0.101707E+10 | 0.00 | 0.42 | 29-APR-16:03 | 0.00 | 01-APR-17:40 | 4721.42 | 29-APR-16:03 | 3435.66 | 28-APR-16:10 | 1393.29 | 29-APR-16:03 | 1234.59 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.901793E+10 | 0.227607E+10 | 744.00 | 0.638851E+10 | 0.262942E+10 | 0.00 | 0.45 | 25-MAY-17:05 | 0.15 | 01-MAY-00:10 | 4979.69 | 26-MAY-11:00 | 3856.29 | 25-MAY-17:17 | 1703.05 | 26-MAY-11:00 | 1329.86 | 25-MAY-17:05 | 0.00 | 01-MAY-00:10 |
| June | 0.929303E+10 | 0.236850E+10 | 720.00 | 0.661041E+10 | 0.268261E+10 | 0.00 | 0.49 | 28-JUN-18:00 | 0.13 | 07-JUN-05:10 | 5471.77 | 28-JUN-18:00 | 4073.91 | 28-JUN-18:00 | 1629.12 | 29-JUN-17:10 | 1465.49 | 28-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.103920E+11 | 0.263247E+10 | 744.00 | 0.698113E+10 | 0.341088E+10 | 0.00 | 0.52 | 03-JUL-16:40 | 0.21 | 12-JUL-04:00 | 5869.74 | 03-JUL-16:40 | 4103.66 | 19-JUL-13:00 | 1983.23 | 03-JUL-16:30 | 1547.92 | 03-JUL-16:40 | 0.00 | 01-JUL-00:10 |
| August | 0.982977E+10 | 0.248310E+10 | 744.00 | 0.666570E+10 | 0.316407E+10 | 0.00 | 0.50 | 03-AUG-16:02 | 0.17 | 17-AUG-02:40 | 5596.33 | 17-AUG-16:03 | 4197.07 | 03-AUG-16:17 | 1967.06 | 10-AUG-20:20 | 1534.68 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.869388E+10 | 0.216023E+10 | 720.00 | 0.576554E+10 | 0.292834E+10 | 0.00 | 0.53 | 09-SEP-17:10 | 0.16 | 22-SEP-03:00 | 5774.83 | 09-SEP-17:10 | 4208.35 | 09-SEP-17:04 | 1939.71 | 18-SEP-16:13 | 1643.98 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.695990E+10 | 0.173690E+10 | 695.47 | 0.481901E+10 | 0.214088E+10 | 0.00 | 0.48 | 08-OCT-16:03 | 0.00 | 17-OCT-05:03 | 5432.91 | 08-OCT-16:03 | 3625.11 | 08-OCT-16:10 | 2094.95 | 24-OCT-13:00 | 1432.44 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.262659E+10 | 0.650816E+09 | 487.98 | 0.192492E+10 | 0.701666E+09 | 0.00 | 0.35 | 02-NOV-16:02 | 0.00 | 05-NOV-05:03 | 3929.12 | 02-NOV-16:02 | 2777.97 | 02-NOV-16:05 | 1348.11 | 29-NOV-12:20 | 1005.96 | 02-NOV-16:02 | 0.00 | 01-NOV-00:10 |
| December | 0.155299E+10 | 0.381267E+09 | 258.00 | 0.108632E+10 | 0.466670E+09 | 0.00 | 0.30 | 13-DEC-14:00 | 0.00 | 01-DEC-01:00 | 3302.33 | 13-DEC-14:00 | 2438.92 | 13-DEC-15:10 | 1312.19 | 13-DEC-11:10 | 858.26 | 13-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.666312E+11 | 0.167425E+11 | 6585.39 | 0.464240E+11 | 0.202072E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.744268E+09 | 0.182439E+09 | 162.79 | 0.526898E+09 | 0.217371E+09 | 0.00 | 0.24 | 0.00 | 2701.09 | 2009.64 | 873.83 | 655.18 | 0.00 | |||||||
| Maximum of Months | 0.103920E+11 | 0.263247E+10 | 744.00 | 0.698113E+10 | 0.341088E+10 | 0.00 | 0.53 | 0.21 | 5869.74 | 4208.35 | 2094.95 | 1643.98 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.742329E+09 | 0.181963E+09 | 162.54 | 0.525413E+09 | 0.216916E+09 | 0.00 | 0.24 | 31-JAN-16:10 | 0.00 | 01-JAN-06:03 | 2690.75 | 31-JAN-16:10 | 2005.04 | 02-JAN-17:10 | 963.68 | 31-JAN-13:00 | 656.62 | 19-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.121964E+10 | 0.300823E+09 | 271.61 | 0.889382E+09 | 0.330260E+09 | 0.00 | 0.26 | 24-FEB-13:00 | 0.00 | 01-FEB-06:05 | 2883.06 | 24-FEB-13:00 | 2146.14 | 25-FEB-17:10 | 872.93 | 02-FEB-22:10 | 739.40 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.201342E+10 | 0.497992E+09 | 375.24 | 0.149521E+10 | 0.518203E+09 | 0.00 | 0.32 | 28-MAR-16:10 | 0.00 | 01-MAR-06:50 | 3625.63 | 28-MAR-16:10 | 2621.37 | 27-MAR-16:05 | 1355.21 | 07-MAR-17:03 | 892.54 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.429114E+10 | 0.107270E+10 | 663.62 | 0.327381E+10 | 0.101732E+10 | 0.00 | 0.42 | 29-APR-16:03 | 0.00 | 01-APR-17:40 | 4713.51 | 29-APR-16:03 | 3426.39 | 28-APR-16:10 | 1391.13 | 29-APR-16:03 | 1231.61 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.902590E+10 | 0.227796E+10 | 744.00 | 0.639498E+10 | 0.263091E+10 | 0.00 | 0.45 | 25-MAY-17:05 | 0.15 | 01-MAY-00:10 | 4982.63 | 26-MAY-11:00 | 3849.44 | 25-MAY-17:17 | 1703.73 | 26-MAY-11:00 | 1327.78 | 25-MAY-17:05 | 0.00 | 01-MAY-00:10 |
| June | 0.929837E+10 | 0.236974E+10 | 720.00 | 0.661471E+10 | 0.268366E+10 | 0.00 | 0.49 | 28-JUN-18:00 | 0.13 | 07-JUN-05:10 | 5460.33 | 28-JUN-18:00 | 4064.22 | 28-JUN-18:00 | 1629.17 | 29-JUN-17:10 | 1462.49 | 28-JUN-18:00 | 0.00 | 01-JUN-00:10 |
| July | 0.104002E+11 | 0.263440E+10 | 744.00 | 0.698784E+10 | 0.341241E+10 | 0.00 | 0.52 | 03-JUL-16:40 | 0.21 | 12-JUL-04:00 | 5865.29 | 03-JUL-16:40 | 4113.74 | 19-JUL-13:00 | 1982.29 | 03-JUL-16:30 | 1546.68 | 03-JUL-16:40 | 0.00 | 01-JUL-00:10 |
| August | 0.983221E+10 | 0.248360E+10 | 744.00 | 0.666748E+10 | 0.316473E+10 | 0.00 | 0.50 | 03-AUG-16:02 | 0.17 | 17-AUG-02:40 | 5591.07 | 17-AUG-16:03 | 4192.21 | 03-AUG-16:17 | 1967.43 | 10-AUG-20:20 | 1533.16 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.869461E+10 | 0.216033E+10 | 720.00 | 0.576586E+10 | 0.292875E+10 | 0.00 | 0.53 | 09-SEP-17:10 | 0.16 | 22-SEP-03:00 | 5760.93 | 09-SEP-17:10 | 4196.40 | 09-SEP-17:04 | 1937.14 | 18-SEP-16:13 | 1640.21 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.695927E+10 | 0.173668E+10 | 695.29 | 0.481823E+10 | 0.214104E+10 | 0.00 | 0.48 | 08-OCT-16:03 | 0.00 | 17-OCT-05:03 | 5421.25 | 08-OCT-16:03 | 3615.99 | 08-OCT-16:10 | 2095.96 | 24-OCT-13:00 | 1432.58 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.263015E+10 | 0.651713E+09 | 488.98 | 0.192808E+10 | 0.702064E+09 | 0.00 | 0.35 | 02-NOV-16:02 | 0.00 | 05-NOV-05:03 | 3920.93 | 02-NOV-16:02 | 2771.97 | 02-NOV-16:05 | 1349.09 | 29-NOV-12:20 | 1005.16 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.154898E+10 | 0.380277E+09 | 257.17 | 0.108304E+10 | 0.465944E+09 | 0.00 | 0.30 | 13-DEC-14:00 | 0.00 | 01-DEC-01:00 | 3298.31 | 13-DEC-14:00 | 2430.38 | 13-DEC-15:10 | 1312.23 | 13-DEC-11:10 | 857.20 | 13-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.666563E+11 | 0.167482E+11 | 6586.45 | 0.464440E+11 | 0.202122E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.742329E+09 | 0.181963E+09 | 162.54 | 0.525413E+09 | 0.216916E+09 | 0.00 | 0.24 | 0.00 | 2690.75 | 2005.04 | 872.93 | 656.62 | 0.00 | |||||||
| Maximum of Months | 0.104002E+11 | 0.263440E+10 | 744.00 | 0.698784E+10 | 0.341241E+10 | 0.00 | 0.53 | 0.21 | 5865.29 | 4196.40 | 2095.96 | 1640.21 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.206586E+10 | 0.511988E+09 | 390.02 | 0.169433E+10 | 0.371533E+09 | 0.00 | 0.45 | 19-JAN-14:00 | 0.00 | 03-JAN-01:00 | 5320.21 | 19-JAN-14:00 | 4472.39 | 01-JAN-14:00 | 1483.55 | 19-JAN-10:40 | 1276.58 | 19-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.266920E+10 | 0.659616E+09 | 442.12 | 0.215290E+10 | 0.516300E+09 | 0.00 | 0.42 | 02-FEB-13:30 | 0.00 | 01-FEB-06:05 | 4843.25 | 02-FEB-13:00 | 4001.43 | 02-FEB-13:30 | 1100.00 | 02-FEB-10:50 | 1241.05 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.297446E+10 | 0.738202E+09 | 489.38 | 0.236118E+10 | 0.613277E+09 | 0.00 | 0.39 | 06-MAR-13:00 | 0.00 | 01-MAR-06:50 | 4500.99 | 06-MAR-13:00 | 3624.92 | 05-MAR-13:40 | 1470.73 | 07-MAR-17:03 | 1131.92 | 06-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.495874E+10 | 0.124102E+10 | 689.03 | 0.388271E+10 | 0.107603E+10 | 0.00 | 0.45 | 29-APR-16:03 | 0.00 | 02-APR-01:30 | 5296.47 | 29-APR-16:03 | 3849.80 | 28-APR-15:10 | 1485.06 | 29-APR-16:03 | 1365.76 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.905883E+10 | 0.229187E+10 | 744.00 | 0.644045E+10 | 0.261838E+10 | 0.00 | 0.43 | 28-MAY-16:10 | 0.15 | 01-MAY-00:10 | 4902.39 | 26-MAY-11:00 | 3856.64 | 07-MAY-17:08 | 1674.61 | 26-MAY-11:00 | 1331.84 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.911071E+10 | 0.232838E+10 | 720.00 | 0.646928E+10 | 0.264143E+10 | 0.00 | 0.45 | 17-JUN-16:15 | 0.13 | 07-JUN-01:50 | 5188.46 | 17-JUN-16:15 | 4019.03 | 10-JUN-16:20 | 1573.84 | 29-JUN-17:20 | 1410.93 | 17-JUN-16:15 | 0.00 | 01-JUN-00:10 |
| July | 0.103402E+11 | 0.262587E+10 | 744.00 | 0.694681E+10 | 0.339336E+10 | 0.00 | 0.50 | 22-JUL-16:10 | 0.20 | 12-JUL-04:00 | 5710.05 | 03-JUL-16:30 | 4228.57 | 22-JUL-16:03 | 1916.38 | 03-JUL-16:13 | 1620.56 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.101644E+11 | 0.257310E+10 | 744.00 | 0.697167E+10 | 0.319277E+10 | 0.00 | 0.49 | 03-AUG-16:02 | 0.16 | 17-AUG-02:30 | 5658.22 | 17-AUG-16:02 | 4497.66 | 30-AUG-16:03 | 1990.27 | 10-AUG-20:20 | 1562.28 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.954439E+10 | 0.237471E+10 | 720.00 | 0.650053E+10 | 0.304386E+10 | 0.00 | 0.57 | 10-SEP-13:30 | 0.16 | 28-SEP-04:00 | 6654.41 | 10-SEP-13:30 | 4771.76 | 10-SEP-14:00 | 2056.16 | 18-SEP-14:20 | 1851.40 | 10-SEP-13:40 | 0.00 | 01-SEP-00:10 |
| October | 0.873233E+10 | 0.217798E+10 | 722.92 | 0.639195E+10 | 0.234039E+10 | 0.00 | 0.60 | 08-OCT-14:00 | 0.00 | 17-OCT-05:30 | 7149.81 | 08-OCT-14:00 | 5187.21 | 09-OCT-14:00 | 2337.76 | 24-OCT-13:30 | 1898.52 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.490704E+10 | 0.122018E+10 | 651.58 | 0.402641E+10 | 0.880634E+09 | 0.00 | 0.51 | 07-NOV-13:30 | 0.00 | 05-NOV-05:03 | 6022.40 | 07-NOV-13:30 | 4484.77 | 02-NOV-15:10 | 1872.15 | 29-NOV-12:20 | 1502.97 | 07-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.333130E+10 | 0.824690E+09 | 467.49 | 0.269280E+10 | 0.638497E+09 | 0.00 | 0.50 | 16-DEC-13:00 | 0.00 | 01-DEC-03:50 | 5820.23 | 16-DEC-13:00 | 4670.23 | 10-DEC-15:00 | 1504.60 | 14-DEC-11:30 | 1461.19 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.778575E+11 | 0.195676E+11 | 7524.53 | 0.565310E+11 | 0.213265E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.206586E+10 | 0.511988E+09 | 390.02 | 0.169433E+10 | 0.371533E+09 | 0.00 | 0.39 | 0.00 | 4500.99 | 3624.92 | 1100.00 | 1131.92 | 0.00 | |||||||
| Maximum of Months | 0.103402E+11 | 0.262587E+10 | 744.00 | 0.697167E+10 | 0.339336E+10 | 0.00 | 0.60 | 0.20 | 7149.81 | 5187.21 | 2337.76 | 1898.52 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.206892E+10 | 0.512788E+09 | 390.85 | 0.169751E+10 | 0.371409E+09 | 0.00 | 0.45 | 19-JAN-14:00 | 0.00 | 03-JAN-01:00 | 5327.92 | 19-JAN-14:00 | 4478.90 | 01-JAN-14:00 | 1487.87 | 19-JAN-10:40 | 1278.27 | 19-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.266911E+10 | 0.659599E+09 | 442.71 | 0.215308E+10 | 0.516028E+09 | 0.00 | 0.42 | 02-FEB-13:30 | 0.00 | 01-FEB-06:05 | 4848.38 | 02-FEB-13:00 | 4005.01 | 02-FEB-13:30 | 1102.32 | 02-FEB-10:50 | 1242.22 | 02-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.298067E+10 | 0.739719E+09 | 488.83 | 0.236662E+10 | 0.614056E+09 | 0.00 | 0.39 | 06-MAR-13:00 | 0.00 | 01-MAR-06:50 | 4515.39 | 06-MAR-13:00 | 3632.35 | 05-MAR-13:40 | 1471.44 | 07-MAR-17:03 | 1135.35 | 06-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.496063E+10 | 0.124147E+10 | 689.25 | 0.388439E+10 | 0.107623E+10 | 0.00 | 0.45 | 29-APR-16:03 | 0.00 | 02-APR-01:30 | 5288.40 | 29-APR-16:03 | 3846.70 | 28-APR-15:10 | 1483.09 | 29-APR-16:03 | 1363.71 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.906682E+10 | 0.229379E+10 | 744.00 | 0.644695E+10 | 0.261987E+10 | 0.00 | 0.43 | 28-MAY-16:10 | 0.15 | 01-MAY-00:10 | 4905.33 | 26-MAY-11:00 | 3859.54 | 07-MAY-17:08 | 1675.30 | 26-MAY-11:00 | 1330.37 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.911617E+10 | 0.232967E+10 | 720.00 | 0.647365E+10 | 0.264252E+10 | 0.00 | 0.45 | 17-JUN-16:15 | 0.12 | 07-JUN-01:50 | 5178.15 | 17-JUN-16:15 | 4013.45 | 10-JUN-16:20 | 1573.99 | 29-JUN-17:20 | 1408.19 | 17-JUN-16:15 | 0.00 | 01-JUN-00:10 |
| July | 0.103485E+11 | 0.262784E+10 | 744.00 | 0.695355E+10 | 0.339492E+10 | 0.00 | 0.50 | 22-JUL-16:10 | 0.20 | 12-JUL-04:00 | 5713.10 | 23-JUL-16:10 | 4228.18 | 22-JUL-16:03 | 1915.41 | 03-JUL-16:13 | 1620.10 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.101668E+11 | 0.257359E+10 | 744.00 | 0.697342E+10 | 0.319341E+10 | 0.00 | 0.49 | 03-AUG-16:02 | 0.16 | 17-AUG-02:30 | 5653.00 | 17-AUG-16:02 | 4490.87 | 30-AUG-16:03 | 1990.64 | 10-AUG-20:20 | 1560.78 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.954506E+10 | 0.237476E+10 | 720.00 | 0.650081E+10 | 0.304425E+10 | 0.00 | 0.57 | 10-SEP-13:30 | 0.16 | 28-SEP-04:00 | 6663.22 | 10-SEP-13:30 | 4777.95 | 10-SEP-14:00 | 2055.19 | 18-SEP-14:20 | 1853.49 | 10-SEP-13:30 | 0.00 | 01-SEP-00:10 |
| October | 0.873172E+10 | 0.217771E+10 | 722.67 | 0.639108E+10 | 0.234064E+10 | 0.00 | 0.60 | 08-OCT-14:00 | 0.00 | 17-OCT-05:30 | 7150.49 | 08-OCT-14:00 | 5192.13 | 09-OCT-14:00 | 2337.94 | 24-OCT-13:30 | 1898.50 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.490930E+10 | 0.122069E+10 | 651.81 | 0.402847E+10 | 0.880834E+09 | 0.00 | 0.51 | 07-NOV-13:30 | 0.00 | 05-NOV-05:03 | 6030.00 | 07-NOV-13:30 | 4486.93 | 02-NOV-14:20 | 1872.81 | 29-NOV-12:20 | 1504.66 | 07-NOV-13:30 | 0.00 | 01-NOV-00:10 |
| December | 0.332698E+10 | 0.823593E+09 | 467.04 | 0.268891E+10 | 0.638061E+09 | 0.00 | 0.50 | 16-DEC-13:00 | 0.00 | 01-DEC-03:50 | 5827.01 | 16-DEC-13:00 | 4669.89 | 10-DEC-15:00 | 1505.27 | 14-DEC-11:30 | 1462.68 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.778907E+11 | 0.195752E+11 | 7525.16 | 0.565584E+11 | 0.213322E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.206892E+10 | 0.512788E+09 | 390.85 | 0.169751E+10 | 0.371409E+09 | 0.00 | 0.39 | 0.00 | 4515.39 | 3632.35 | 1102.32 | 1135.35 | 0.00 | |||||||
| Maximum of Months | 0.103485E+11 | 0.262784E+10 | 744.00 | 0.697342E+10 | 0.339492E+10 | 0.00 | 0.60 | 0.20 | 7150.49 | 5192.13 | 2337.94 | 1898.50 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.888031E+09 | 0.218979E+09 | 214.65 | 0.729201E+09 | 0.158830E+09 | 0.00 | 0.52 | 19-JAN-15:30 | 0.00 | 01-JAN-01:20 | 4032.63 | 19-JAN-15:30 | 3266.55 | 01-JAN-15:10 | 929.94 | 19-JAN-14:20 | 959.39 | 19-JAN-15:30 | 0.00 | 01-JAN-00:10 |
| February | 0.121507E+10 | 0.299272E+09 | 244.83 | 0.992224E+09 | 0.222841E+09 | 0.00 | 0.49 | 27-FEB-16:10 | 0.00 | 01-FEB-01:40 | 3678.40 | 27-FEB-16:10 | 3160.90 | 27-FEB-16:10 | 719.59 | 21-FEB-13:30 | 895.60 | 27-FEB-16:10 | 0.00 | 01-FEB-00:10 |
| March | 0.151154E+10 | 0.374780E+09 | 313.58 | 0.121397E+10 | 0.297569E+09 | 0.00 | 0.48 | 06-MAR-16:10 | 0.00 | 01-MAR-00:50 | 3685.59 | 06-MAR-16:10 | 2932.75 | 26-MAR-16:10 | 1066.19 | 07-MAR-16:30 | 897.08 | 06-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.276583E+10 | 0.694154E+09 | 530.17 | 0.220718E+10 | 0.558649E+09 | 0.00 | 0.62 | 29-APR-16:03 | 0.00 | 01-APR-17:40 | 4862.14 | 29-APR-16:03 | 3691.05 | 28-APR-15:30 | 1219.35 | 29-APR-16:03 | 1225.48 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.590152E+10 | 0.150062E+10 | 744.00 | 0.428568E+10 | 0.161583E+10 | 0.00 | 0.60 | 28-MAY-16:30 | 0.06 | 01-MAY-00:10 | 4500.81 | 28-MAY-16:50 | 3783.92 | 10-MAY-16:10 | 1220.68 | 26-MAY-11:00 | 1211.40 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.606568E+10 | 0.155830E+10 | 720.00 | 0.445972E+10 | 0.160596E+10 | 0.00 | 0.62 | 28-JUN-15:30 | 0.03 | 07-JUN-05:30 | 4694.57 | 28-JUN-15:20 | 3837.70 | 10-JUN-16:30 | 1163.47 | 29-JUN-15:30 | 1259.60 | 28-JUN-15:20 | 0.00 | 01-JUN-00:10 |
| July | 0.682098E+10 | 0.173884E+10 | 744.00 | 0.471533E+10 | 0.210565E+10 | 0.00 | 0.66 | 22-JUL-16:30 | 0.11 | 15-JUL-04:00 | 4915.58 | 22-JUL-16:30 | 3960.09 | 22-JUL-16:30 | 1470.16 | 03-JUL-16:13 | 1369.35 | 22-JUL-16:01 | 0.00 | 01-JUL-00:10 |
| August | 0.669047E+10 | 0.169938E+10 | 744.00 | 0.469290E+10 | 0.199757E+10 | 0.00 | 0.68 | 03-AUG-16:02 | 0.06 | 17-AUG-03:00 | 5043.74 | 03-AUG-16:02 | 4244.39 | 30-AUG-16:03 | 1482.28 | 13-AUG-14:30 | 1394.92 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.595804E+10 | 0.148774E+10 | 720.00 | 0.410459E+10 | 0.185345E+10 | 0.00 | 0.73 | 09-SEP-16:50 | 0.07 | 07-SEP-23:10 | 5497.62 | 09-SEP-16:40 | 4332.63 | 09-SEP-16:40 | 1623.22 | 18-SEP-14:30 | 1527.12 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.526415E+10 | 0.131526E+10 | 651.47 | 0.384903E+10 | 0.141512E+10 | 0.00 | 0.74 | 08-OCT-15:30 | 0.00 | 01-OCT-05:05 | 5928.67 | 08-OCT-15:30 | 4335.18 | 08-OCT-15:30 | 1749.43 | 24-OCT-13:30 | 1516.41 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.219048E+10 | 0.544645E+09 | 425.77 | 0.176933E+10 | 0.421152E+09 | 0.00 | 0.61 | 02-NOV-15:10 | 0.00 | 05-NOV-01:10 | 4692.05 | 02-NOV-15:10 | 3741.10 | 02-NOV-15:10 | 1217.50 | 29-NOV-12:30 | 1183.57 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.149961E+10 | 0.371290E+09 | 309.81 | 0.121038E+10 | 0.289238E+09 | 0.00 | 0.54 | 15-DEC-15:10 | 0.00 | 01-DEC-00:10 | 4128.38 | 16-DEC-13:40 | 3558.78 | 10-DEC-15:10 | 974.98 | 14-DEC-11:30 | 1044.00 | 15-DEC-15:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.467714E+11 | 0.118033E+11 | 6362.28 | 0.342295E+11 | 0.125419E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.888031E+09 | 0.218979E+09 | 214.65 | 0.729201E+09 | 0.158830E+09 | 0.00 | 0.48 | 0.00 | 3678.40 | 2932.75 | 719.59 | 895.60 | 0.00 | |||||||
| Maximum of Months | 0.682098E+10 | 0.173884E+10 | 744.00 | 0.471533E+10 | 0.210565E+10 | 0.00 | 0.74 | 0.11 | 5928.67 | 4335.18 | 1749.43 | 1527.12 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.396586E+09 | 97529624.23 | 119.33 | 0.291529E+09 | 0.105057E+09 | 0.00 | 0.34 | 31-JAN-16:10 | 0.00 | 01-JAN-00:10 | 2515.13 | 31-JAN-16:10 | 1791.37 | 31-JAN-16:10 | 739.08 | 31-JAN-17:10 | 604.27 | 31-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.625682E+09 | 0.154573E+09 | 176.72 | 0.471984E+09 | 0.153698E+09 | 0.00 | 0.33 | 27-FEB-16:20 | 0.00 | 01-FEB-01:10 | 2448.42 | 27-FEB-16:30 | 1976.26 | 27-FEB-16:20 | 597.03 | 28-FEB-17:20 | 603.16 | 27-FEB-16:20 | 0.00 | 01-FEB-00:10 |
| March | 0.109114E+10 | 0.270645E+09 | 271.33 | 0.832787E+09 | 0.258350E+09 | 0.00 | 0.39 | 26-MAR-16:10 | 0.00 | 01-MAR-00:10 | 2880.76 | 26-MAR-16:10 | 2390.62 | 26-MAR-16:10 | 988.51 | 07-MAR-16:30 | 715.82 | 26-MAR-16:10 | 0.00 | 01-MAR-00:10 |
| April | 0.243685E+10 | 0.611938E+09 | 510.65 | 0.190531E+10 | 0.531532E+09 | 0.00 | 0.59 | 29-APR-16:03 | 0.00 | 01-APR-17:02 | 4479.28 | 29-APR-16:03 | 3441.47 | 28-APR-16:10 | 1165.88 | 29-APR-16:03 | 1150.26 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.587926E+10 | 0.149264E+10 | 744.00 | 0.425958E+10 | 0.161968E+10 | 0.00 | 0.60 | 28-MAY-16:30 | 0.06 | 01-MAY-00:10 | 4476.47 | 28-MAY-17:10 | 3710.20 | 10-MAY-16:30 | 1232.44 | 26-MAY-11:00 | 1180.91 | 28-MAY-16:30 | 0.00 | 01-MAY-00:10 |
| June | 0.615641E+10 | 0.157844E+10 | 720.00 | 0.453422E+10 | 0.162218E+10 | 0.00 | 0.65 | 28-JUN-17:30 | 0.02 | 07-JUN-05:30 | 4805.69 | 28-JUN-17:30 | 3837.13 | 28-JUN-17:30 | 1180.89 | 29-JUN-15:30 | 1270.95 | 28-JUN-17:30 | 0.00 | 01-JUN-00:10 |
| July | 0.684735E+10 | 0.174278E+10 | 744.00 | 0.473644E+10 | 0.211091E+10 | 0.00 | 0.65 | 18-JUL-16:02 | 0.12 | 15-JUL-04:00 | 4799.13 | 18-JUL-16:02 | 3906.14 | 07-JUL-16:30 | 1505.40 | 03-JUL-16:13 | 1319.83 | 22-JUL-16:30 | 0.00 | 01-JUL-00:10 |
| August | 0.650341E+10 | 0.165040E+10 | 744.00 | 0.452159E+10 | 0.198183E+10 | 0.00 | 0.68 | 03-AUG-16:13 | 0.06 | 17-AUG-03:00 | 4969.19 | 03-AUG-16:13 | 4050.16 | 03-AUG-16:17 | 1469.71 | 13-AUG-14:30 | 1369.14 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.550191E+10 | 0.137442E+10 | 720.00 | 0.370722E+10 | 0.179469E+10 | 0.00 | 0.70 | 09-SEP-17:00 | 0.07 | 07-SEP-23:10 | 5102.54 | 09-SEP-17:10 | 3968.59 | 09-SEP-17:00 | 1550.75 | 18-SEP-14:30 | 1425.56 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.435449E+10 | 0.109146E+10 | 624.87 | 0.304350E+10 | 0.131098E+10 | 0.00 | 0.63 | 08-OCT-15:40 | 0.00 | 01-OCT-05:05 | 4835.74 | 08-OCT-15:30 | 3396.87 | 07-OCT-16:20 | 1600.34 | 24-OCT-13:40 | 1231.54 | 08-OCT-15:30 | 0.00 | 01-OCT-00:10 |
| November | 0.124492E+10 | 0.309659E+09 | 321.99 | 0.905137E+09 | 0.339778E+09 | 0.00 | 0.46 | 02-NOV-15:20 | 0.00 | 05-NOV-00:20 | 3415.32 | 02-NOV-15:20 | 2566.05 | 02-NOV-16:03 | 1038.50 | 07-NOV-14:00 | 873.61 | 02-NOV-15:20 | 0.00 | 01-NOV-00:10 |
| December | 0.762474E+09 | 0.188759E+09 | 204.34 | 0.546554E+09 | 0.215920E+09 | 0.00 | 0.38 | 13-DEC-15:30 | 0.00 | 01-DEC-00:10 | 2734.52 | 13-DEC-15:20 | 2223.55 | 13-DEC-16:10 | 797.07 | 13-DEC-11:30 | 720.90 | 13-DEC-15:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.418005E+11 | 0.105632E+11 | 5901.23 | 0.297559E+11 | 0.120446E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.396586E+09 | 97529624.23 | 119.33 | 0.291529E+09 | 0.105057E+09 | 0.00 | 0.33 | 0.00 | 2448.42 | 1791.37 | 597.03 | 603.16 | 0.00 | |||||||
| Maximum of Months | 0.684735E+10 | 0.174278E+10 | 744.00 | 0.473644E+10 | 0.211091E+10 | 0.00 | 0.70 | 0.12 | 5102.54 | 4050.16 | 1600.34 | 1425.56 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.834245E+09 | 0.205069E+09 | 215.86 | 0.680336E+09 | 0.153909E+09 | 0.00 | 0.54 | 19-JAN-13:40 | 0.00 | 01-JAN-01:10 | 3865.31 | 19-JAN-13:40 | 3114.67 | 01-JAN-14:00 | 1070.27 | 19-JAN-10:40 | 913.22 | 19-JAN-13:40 | 0.00 | 01-JAN-00:10 |
| February | 0.116625E+10 | 0.286390E+09 | 243.83 | 0.947855E+09 | 0.218400E+09 | 0.00 | 0.50 | 02-FEB-13:30 | 0.00 | 01-FEB-01:10 | 3431.24 | 24-FEB-13:50 | 2846.87 | 24-FEB-14:00 | 776.22 | 24-FEB-11:00 | 863.09 | 02-FEB-13:30 | 0.00 | 01-FEB-00:10 |
| March | 0.153206E+10 | 0.378331E+09 | 319.78 | 0.122782E+10 | 0.304233E+09 | 0.00 | 0.50 | 07-MAR-11:40 | 0.00 | 01-MAR-00:30 | 3572.00 | 07-MAR-11:30 | 2822.58 | 26-MAR-14:00 | 1024.15 | 07-MAR-16:30 | 855.54 | 07-MAR-11:30 | 0.00 | 01-MAR-00:10 |
| April | 0.274252E+10 | 0.685935E+09 | 532.46 | 0.218426E+10 | 0.558253E+09 | 0.00 | 0.59 | 29-APR-16:10 | 0.00 | 01-APR-17:30 | 4211.70 | 29-APR-16:10 | 3257.32 | 28-APR-15:10 | 1118.69 | 29-APR-16:03 | 1065.30 | 29-APR-15:40 | 0.00 | 01-APR-00:10 |
| May | 0.600201E+10 | 0.151756E+10 | 744.00 | 0.436842E+10 | 0.163360E+10 | 0.00 | 0.59 | 25-MAY-14:00 | 0.06 | 01-MAY-00:10 | 4115.75 | 25-MAY-14:00 | 3355.19 | 07-MAY-14:00 | 1316.67 | 27-MAY-09:10 | 1100.41 | 25-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.613060E+10 | 0.156635E+10 | 720.00 | 0.451459E+10 | 0.161601E+10 | 0.00 | 0.62 | 28-JUN-15:10 | 0.03 | 07-JUN-05:30 | 4324.75 | 28-JUN-15:10 | 3323.41 | 10-JUN-16:20 | 1195.89 | 19-JUN-08:40 | 1158.87 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.692590E+10 | 0.175572E+10 | 744.00 | 0.480806E+10 | 0.211784E+10 | 0.00 | 0.70 | 19-JUL-13:00 | 0.12 | 15-JUL-04:00 | 4879.60 | 19-JUL-13:00 | 3830.40 | 19-JUL-13:00 | 1429.66 | 03-JUL-16:13 | 1307.07 | 19-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.670161E+10 | 0.169307E+10 | 744.00 | 0.470297E+10 | 0.199864E+10 | 0.00 | 0.66 | 03-AUG-16:02 | 0.07 | 17-AUG-03:00 | 4492.51 | 03-AUG-16:02 | 3644.21 | 03-AUG-16:10 | 1469.05 | 10-AUG-20:20 | 1244.17 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.594756E+10 | 0.147767E+10 | 720.00 | 0.409667E+10 | 0.185089E+10 | 0.00 | 0.77 | 10-SEP-12:50 | 0.08 | 08-SEP-00:10 | 5391.81 | 10-SEP-13:00 | 4104.87 | 10-SEP-13:00 | 1519.93 | 18-SEP-14:30 | 1453.69 | 10-SEP-12:00 | 0.00 | 01-SEP-00:10 |
| October | 0.522590E+10 | 0.129842E+10 | 650.92 | 0.381115E+10 | 0.141474E+10 | 0.00 | 0.78 | 08-OCT-14:00 | 0.00 | 01-OCT-05:05 | 5614.60 | 08-OCT-14:00 | 4148.49 | 09-OCT-14:00 | 1700.40 | 24-OCT-13:30 | 1451.28 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.216376E+10 | 0.536014E+09 | 429.21 | 0.174315E+10 | 0.420613E+09 | 0.00 | 0.62 | 07-NOV-13:30 | 0.00 | 05-NOV-01:00 | 4475.05 | 07-NOV-13:30 | 3518.59 | 02-NOV-13:30 | 1214.48 | 29-NOV-12:30 | 1099.34 | 02-NOV-13:00 | 0.00 | 01-NOV-00:10 |
| December | 0.141933E+10 | 0.350225E+09 | 301.84 | 0.113695E+10 | 0.282382E+09 | 0.00 | 0.60 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 | 4212.66 | 16-DEC-13:00 | 3389.26 | 16-DEC-13:30 | 1011.04 | 16-DEC-10:00 | 1042.37 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.467918E+11 | 0.117508E+11 | 6365.90 | 0.342222E+11 | 0.125695E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.834245E+09 | 0.205069E+09 | 215.86 | 0.680336E+09 | 0.153909E+09 | 0.00 | 0.50 | 0.00 | 3431.24 | 2822.58 | 776.22 | 855.54 | 0.00 | |||||||
| Maximum of Months | 0.692590E+10 | 0.175572E+10 | 744.00 | 0.480806E+10 | 0.211784E+10 | 0.00 | 0.78 | 0.12 | 5614.60 | 4148.49 | 1700.40 | 1453.69 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.363794E+09 | 89386196.33 | 120.25 | 0.264546E+09 | 99248049.51 | 0.00 | 0.31 | 19-JAN-12:00 | 0.00 | 01-JAN-00:10 | 2090.63 | 19-JAN-12:00 | 1440.54 | 19-JAN-12:10 | 693.53 | 19-JAN-10:50 | 513.49 | 19-JAN-12:00 | 0.00 | 01-JAN-00:10 |
| February | 0.581436E+09 | 0.143513E+09 | 173.67 | 0.434077E+09 | 0.147358E+09 | 0.00 | 0.33 | 24-FEB-13:00 | 0.00 | 01-FEB-00:30 | 2174.65 | 24-FEB-13:00 | 1622.96 | 24-FEB-13:40 | 591.15 | 24-FEB-11:20 | 553.75 | 24-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.111408E+10 | 0.275337E+09 | 277.22 | 0.847783E+09 | 0.266294E+09 | 0.00 | 0.40 | 28-MAR-15:10 | 0.00 | 01-MAR-00:10 | 2761.37 | 28-MAR-15:20 | 2254.98 | 26-MAR-14:00 | 945.69 | 07-MAR-16:30 | 691.01 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.241196E+10 | 0.603746E+09 | 510.22 | 0.188021E+10 | 0.531751E+09 | 0.00 | 0.56 | 29-APR-16:03 | 0.00 | 01-APR-16:00 | 3833.27 | 29-APR-16:03 | 2916.99 | 28-APR-15:10 | 1059.35 | 29-APR-16:03 | 979.12 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.597966E+10 | 0.150919E+10 | 744.00 | 0.434229E+10 | 0.163737E+10 | 0.00 | 0.60 | 25-MAY-14:00 | 0.06 | 01-MAY-00:10 | 4051.58 | 25-MAY-14:00 | 3130.81 | 28-MAY-16:10 | 1286.56 | 27-MAY-08:40 | 1081.52 | 25-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.622047E+10 | 0.158547E+10 | 720.00 | 0.458891E+10 | 0.163156E+10 | 0.00 | 0.64 | 28-JUN-15:10 | 0.02 | 07-JUN-05:30 | 4327.16 | 28-JUN-15:10 | 3301.38 | 28-JUN-15:10 | 1240.37 | 19-JUN-08:40 | 1155.99 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.695175E+10 | 0.175885E+10 | 744.00 | 0.482883E+10 | 0.212293E+10 | 0.00 | 0.71 | 19-JUL-13:00 | 0.13 | 15-JUL-04:00 | 4858.20 | 19-JUL-13:00 | 3802.85 | 19-JUL-13:00 | 1466.04 | 03-JUL-16:13 | 1297.79 | 19-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.651532E+10 | 0.164445E+10 | 744.00 | 0.453162E+10 | 0.198370E+10 | 0.00 | 0.66 | 03-AUG-16:02 | 0.07 | 17-AUG-03:00 | 4408.13 | 03-AUG-16:02 | 3543.46 | 03-AUG-16:08 | 1457.87 | 10-AUG-20:20 | 1218.95 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.549326E+10 | 0.136581E+10 | 720.00 | 0.369984E+10 | 0.179342E+10 | 0.00 | 0.69 | 10-SEP-12:00 | 0.08 | 07-SEP-23:10 | 4687.60 | 10-SEP-12:00 | 3471.44 | 10-SEP-12:00 | 1434.94 | 18-SEP-14:30 | 1279.19 | 10-SEP-12:00 | 0.00 | 01-SEP-00:10 |
| October | 0.432751E+10 | 0.107930E+10 | 622.50 | 0.301463E+10 | 0.131289E+10 | 0.00 | 0.64 | 08-OCT-14:00 | 0.00 | 01-OCT-05:05 | 4414.92 | 08-OCT-14:00 | 3055.50 | 07-OCT-13:00 | 1558.18 | 24-OCT-13:00 | 1161.29 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.122088E+10 | 0.302766E+09 | 318.35 | 0.881869E+09 | 0.339007E+09 | 0.00 | 0.44 | 02-NOV-15:10 | 0.00 | 05-NOV-00:10 | 3027.73 | 07-NOV-13:40 | 2200.04 | 02-NOV-13:30 | 985.17 | 07-NOV-13:40 | 765.76 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.707034E+09 | 0.174601E+09 | 201.00 | 0.499387E+09 | 0.207647E+09 | 0.00 | 0.37 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 | 2466.06 | 16-DEC-13:00 | 1816.97 | 16-DEC-13:00 | 811.10 | 13-DEC-11:20 | 626.37 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.418871E+11 | 0.105324E+11 | 5895.21 | 0.298140E+11 | 0.120732E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.363794E+09 | 89386196.33 | 120.25 | 0.264546E+09 | 99248049.51 | 0.00 | 0.31 | 0.00 | 2090.63 | 1440.54 | 591.15 | 513.49 | 0.00 | |||||||
| Maximum of Months | 0.695175E+10 | 0.175885E+10 | 744.00 | 0.482883E+10 | 0.212293E+10 | 0.00 | 0.71 | 0.13 | 4858.20 | 3802.85 | 1558.18 | 1297.79 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.335161E+09 | 82296474.10 | 130.54 | 0.240211E+09 | 94950209.41 | 0.00 | 0.28 | 31-JAN-16:10 | 0.00 | 01-JAN-01:00 | 1742.97 | 31-JAN-16:10 | 1230.86 | 31-JAN-16:10 | 585.83 | 31-JAN-13:00 | 421.72 | 31-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.506093E+09 | 0.124974E+09 | 181.89 | 0.372194E+09 | 0.133899E+09 | 0.00 | 0.28 | 24-FEB-14:00 | 0.00 | 01-FEB-02:30 | 1677.56 | 24-FEB-14:00 | 1258.37 | 27-FEB-16:10 | 488.53 | 24-FEB-13:00 | 427.42 | 24-FEB-13:50 | 0.00 | 01-FEB-00:10 |
| March | 0.931681E+09 | 0.230589E+09 | 290.58 | 0.695712E+09 | 0.235969E+09 | 0.00 | 0.36 | 28-MAR-16:10 | 0.00 | 01-MAR-01:10 | 2223.15 | 28-MAR-16:10 | 1773.14 | 26-MAR-14:00 | 800.36 | 07-MAR-17:03 | 549.44 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.205177E+10 | 0.514553E+09 | 534.81 | 0.157573E+10 | 0.476031E+09 | 0.00 | 0.51 | 28-APR-16:10 | 0.00 | 01-APR-17:00 | 3121.51 | 29-APR-16:03 | 2402.89 | 28-APR-16:10 | 837.11 | 29-APR-16:03 | 824.87 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.503475E+10 | 0.127554E+10 | 744.00 | 0.363130E+10 | 0.140346E+10 | 0.00 | 0.53 | 25-MAY-16:50 | 0.08 | 01-MAY-00:10 | 3214.97 | 25-MAY-14:10 | 2620.79 | 28-MAY-16:20 | 1007.75 | 26-MAY-11:00 | 868.47 | 25-MAY-14:10 | 0.00 | 01-MAY-00:10 |
| June | 0.526519E+10 | 0.134636E+10 | 720.00 | 0.383664E+10 | 0.142856E+10 | 0.00 | 0.57 | 28-JUN-15:10 | 0.05 | 07-JUN-05:30 | 3527.02 | 28-JUN-15:10 | 2736.32 | 28-JUN-17:30 | 940.13 | 19-JUN-08:40 | 951.56 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.587228E+10 | 0.149144E+10 | 744.00 | 0.403749E+10 | 0.183479E+10 | 0.00 | 0.60 | 19-JUL-13:00 | 0.14 | 15-JUL-04:00 | 3691.86 | 03-JUL-16:30 | 2862.50 | 19-JUL-13:00 | 1164.16 | 03-JUL-16:13 | 1009.20 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.552187E+10 | 0.139910E+10 | 744.00 | 0.382003E+10 | 0.170184E+10 | 0.00 | 0.60 | 03-AUG-16:02 | 0.09 | 17-AUG-03:00 | 3608.44 | 03-AUG-16:02 | 2898.56 | 03-AUG-16:08 | 1132.51 | 10-AUG-20:20 | 1008.38 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.472040E+10 | 0.117700E+10 | 720.00 | 0.316812E+10 | 0.155229E+10 | 0.00 | 0.61 | 09-SEP-17:00 | 0.10 | 08-SEP-00:10 | 3706.51 | 09-SEP-17:10 | 2815.75 | 09-SEP-17:00 | 1151.95 | 18-SEP-14:30 | 1046.10 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.368665E+10 | 0.922944E+09 | 632.72 | 0.256463E+10 | 0.112202E+10 | 0.00 | 0.56 | 08-OCT-14:00 | 0.00 | 01-OCT-05:05 | 3505.62 | 08-OCT-14:10 | 2437.04 | 05-OCT-15:10 | 1242.31 | 24-OCT-13:00 | 934.23 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.108784E+10 | 0.269737E+09 | 334.08 | 0.776562E+09 | 0.311275E+09 | 0.00 | 0.40 | 02-NOV-15:10 | 0.00 | 05-NOV-01:30 | 2489.63 | 02-NOV-15:10 | 1810.14 | 02-NOV-15:10 | 794.45 | 07-NOV-13:40 | 641.89 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.668444E+09 | 0.164695E+09 | 214.74 | 0.464896E+09 | 0.203548E+09 | 0.00 | 0.33 | 15-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2034.06 | 15-DEC-14:00 | 1553.25 | 15-DEC-15:00 | 718.68 | 13-DEC-11:20 | 530.32 | 13-DEC-15:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.356821E+11 | 0.899923E+10 | 5991.36 | 0.251835E+11 | 0.104986E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.335161E+09 | 82296474.10 | 130.54 | 0.240211E+09 | 94950209.41 | 0.00 | 0.28 | 0.00 | 1677.56 | 1230.86 | 488.53 | 421.72 | 0.00 | |||||||
| Maximum of Months | 0.587228E+10 | 0.149144E+10 | 744.00 | 0.403749E+10 | 0.183479E+10 | 0.00 | 0.61 | 0.14 | 3706.51 | 2898.56 | 1242.31 | 1046.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.334894E+09 | 82233900.76 | 130.33 | 0.240055E+09 | 94838961.42 | 0.00 | 0.28 | 31-JAN-16:10 | 0.00 | 01-JAN-01:00 | 1731.70 | 31-JAN-16:10 | 1222.10 | 31-JAN-16:10 | 586.32 | 31-JAN-13:00 | 419.02 | 31-JAN-16:10 | 0.00 | 01-JAN-00:10 |
| February | 0.505506E+09 | 0.124830E+09 | 182.06 | 0.371750E+09 | 0.133756E+09 | 0.00 | 0.28 | 24-FEB-14:00 | 0.00 | 01-FEB-02:30 | 1690.46 | 24-FEB-13:00 | 1267.37 | 24-FEB-14:00 | 489.53 | 24-FEB-13:00 | 431.16 | 24-FEB-13:00 | 0.00 | 01-FEB-00:10 |
| March | 0.935563E+09 | 0.231531E+09 | 290.75 | 0.698902E+09 | 0.236661E+09 | 0.00 | 0.36 | 28-MAR-16:10 | 0.00 | 01-MAR-01:10 | 2226.95 | 28-MAR-16:10 | 1781.13 | 26-MAR-14:00 | 800.69 | 07-MAR-17:03 | 551.86 | 30-MAR-13:00 | 0.00 | 01-MAR-00:10 |
| April | 0.205377E+10 | 0.515026E+09 | 535.06 | 0.157752E+10 | 0.476244E+09 | 0.00 | 0.51 | 28-APR-16:10 | 0.00 | 01-APR-17:00 | 3110.50 | 29-APR-16:03 | 2395.27 | 28-APR-15:10 | 834.91 | 29-APR-16:03 | 821.40 | 28-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.503966E+10 | 0.127658E+10 | 744.00 | 0.363507E+10 | 0.140459E+10 | 0.00 | 0.53 | 25-MAY-14:10 | 0.08 | 01-MAY-00:10 | 3218.85 | 25-MAY-14:10 | 2610.99 | 28-MAY-16:20 | 1008.43 | 26-MAY-11:00 | 869.25 | 25-MAY-14:10 | 0.00 | 01-MAY-00:10 |
| June | 0.526863E+10 | 0.134700E+10 | 720.00 | 0.383922E+10 | 0.142941E+10 | 0.00 | 0.58 | 28-JUN-15:10 | 0.05 | 07-JUN-05:30 | 3525.80 | 28-JUN-15:10 | 2723.48 | 28-JUN-17:30 | 945.42 | 19-JUN-08:40 | 951.02 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.587720E+10 | 0.149242E+10 | 744.00 | 0.404133E+10 | 0.183587E+10 | 0.00 | 0.60 | 19-JUL-13:00 | 0.14 | 15-JUL-04:00 | 3690.27 | 19-JUL-13:00 | 2872.39 | 19-JUL-13:00 | 1163.17 | 03-JUL-16:30 | 1007.32 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.552336E+10 | 0.139926E+10 | 744.00 | 0.382091E+10 | 0.170245E+10 | 0.00 | 0.60 | 03-AUG-16:02 | 0.09 | 17-AUG-03:00 | 3598.95 | 03-AUG-16:02 | 2890.46 | 03-AUG-16:08 | 1132.52 | 10-AUG-20:20 | 1005.65 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.472101E+10 | 0.117699E+10 | 720.00 | 0.316828E+10 | 0.155273E+10 | 0.00 | 0.61 | 09-SEP-17:00 | 0.10 | 08-SEP-00:10 | 3697.00 | 10-SEP-13:20 | 2801.84 | 09-SEP-17:00 | 1150.35 | 18-SEP-14:30 | 1041.71 | 09-SEP-17:00 | 0.00 | 01-SEP-00:10 |
| October | 0.368678E+10 | 0.922850E+09 | 632.13 | 0.256438E+10 | 0.112239E+10 | 0.00 | 0.56 | 08-OCT-14:00 | 0.00 | 01-OCT-05:05 | 3506.15 | 08-OCT-14:00 | 2433.08 | 05-OCT-15:10 | 1242.82 | 24-OCT-13:00 | 934.15 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.108943E+10 | 0.270126E+09 | 334.29 | 0.777922E+09 | 0.311504E+09 | 0.00 | 0.40 | 02-NOV-15:10 | 0.00 | 05-NOV-01:30 | 2485.64 | 02-NOV-15:10 | 1807.79 | 02-NOV-15:10 | 794.86 | 07-NOV-13:40 | 640.83 | 02-NOV-15:10 | 0.00 | 01-NOV-00:10 |
| December | 0.667255E+09 | 0.164405E+09 | 214.74 | 0.464032E+09 | 0.203223E+09 | 0.00 | 0.34 | 15-DEC-14:00 | 0.00 | 01-DEC-00:10 | 2032.18 | 15-DEC-14:00 | 1546.49 | 15-DEC-15:00 | 719.68 | 13-DEC-11:20 | 528.54 | 15-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.357031E+11 | 0.900325E+10 | 5991.36 | 0.251994E+11 | 0.105037E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.334894E+09 | 82233900.76 | 130.33 | 0.240055E+09 | 94838961.42 | 0.00 | 0.28 | 0.00 | 1690.46 | 1222.10 | 489.53 | 419.02 | 0.00 | |||||||
| Maximum of Months | 0.587720E+10 | 0.149242E+10 | 744.00 | 0.404133E+10 | 0.183587E+10 | 0.00 | 0.61 | 0.14 | 3697.00 | 2890.46 | 1242.82 | 1041.71 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.842986E+09 | 0.207729E+09 | 253.01 | 0.690287E+09 | 0.152699E+09 | 0.00 | 0.52 | 19-JAN-14:00 | 0.00 | 01-JAN-03:30 | 3407.88 | 19-JAN-14:00 | 2905.48 | 01-JAN-14:30 | 894.45 | 19-JAN-10:40 | 810.21 | 19-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.111020E+10 | 0.273120E+09 | 273.32 | 0.901124E+09 | 0.209073E+09 | 0.00 | 0.47 | 02-FEB-13:30 | 0.00 | 01-FEB-03:20 | 3010.30 | 24-FEB-14:00 | 2563.67 | 27-FEB-14:50 | 647.39 | 24-FEB-11:10 | 760.90 | 02-FEB-13:30 | 0.00 | 01-FEB-00:10 |
| March | 0.134871E+10 | 0.333992E+09 | 346.47 | 0.107276E+10 | 0.275951E+09 | 0.00 | 0.46 | 06-MAR-14:00 | 0.00 | 01-MAR-02:70 | 2918.21 | 06-MAR-14:00 | 2343.27 | 26-MAR-14:00 | 869.15 | 07-MAR-16:40 | 721.14 | 06-MAR-14:00 | 0.00 | 01-MAR-00:10 |
| April | 0.239052E+10 | 0.599388E+09 | 563.36 | 0.188551E+10 | 0.505013E+09 | 0.00 | 0.54 | 29-APR-16:03 | 0.00 | 01-APR-17:50 | 3497.13 | 29-APR-16:03 | 2742.06 | 28-APR-15:10 | 889.71 | 29-APR-16:03 | 892.64 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.505712E+10 | 0.128373E+10 | 744.00 | 0.365763E+10 | 0.139950E+10 | 0.00 | 0.53 | 28-MAY-16:10 | 0.08 | 01-MAY-00:10 | 3277.42 | 25-MAY-14:10 | 2704.99 | 28-MAY-16:10 | 996.21 | 26-MAY-11:00 | 894.06 | 28-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.517262E+10 | 0.132593E+10 | 720.00 | 0.376120E+10 | 0.141142E+10 | 0.00 | 0.56 | 28-JUN-15:10 | 0.06 | 07-JUN-05:10 | 3522.56 | 28-JUN-15:10 | 2766.34 | 10-JUN-16:20 | 916.80 | 29-JUN-15:30 | 953.50 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.584527E+10 | 0.148761E+10 | 744.00 | 0.401638E+10 | 0.182889E+10 | 0.00 | 0.61 | 22-JUL-16:10 | 0.14 | 15-JUL-04:00 | 3777.89 | 22-JUL-16:10 | 2966.63 | 22-JUL-16:03 | 1128.15 | 03-JUL-16:13 | 1063.40 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.571046E+10 | 0.144873E+10 | 744.00 | 0.399278E+10 | 0.171768E+10 | 0.00 | 0.60 | 03-AUG-16:02 | 0.09 | 17-AUG-03:00 | 3691.44 | 03-AUG-16:02 | 3092.49 | 30-AUG-16:03 | 1142.48 | 10-AUG-20:20 | 1033.34 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.517962E+10 | 0.129146E+10 | 720.00 | 0.356944E+10 | 0.161019E+10 | 0.00 | 0.70 | 10-SEP-13:30 | 0.10 | 08-SEP-00:10 | 4454.11 | 10-SEP-13:20 | 3383.18 | 10-SEP-14:00 | 1226.70 | 18-SEP-14:30 | 1220.94 | 10-SEP-13:40 | 0.00 | 01-SEP-00:10 |
| October | 0.460505E+10 | 0.114951E+10 | 665.00 | 0.338239E+10 | 0.122266E+10 | 0.00 | 0.72 | 08-OCT-14:00 | 0.00 | 01-OCT-05:15 | 4699.22 | 08-OCT-14:00 | 3486.02 | 09-OCT-14:00 | 1383.55 | 24-OCT-13:30 | 1229.19 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.206909E+10 | 0.513338E+09 | 465.52 | 0.167224E+10 | 0.396846E+09 | 0.00 | 0.59 | 02-NOV-14:20 | 0.00 | 05-NOV-02:30 | 3829.24 | 02-NOV-14:20 | 3077.78 | 02-NOV-14:10 | 1123.51 | 29-NOV-12:20 | 970.32 | 02-NOV-14:20 | 0.00 | 01-NOV-00:10 |
| December | 0.142537E+10 | 0.351979E+09 | 340.39 | 0.114509E+10 | 0.280282E+09 | 0.00 | 0.57 | 16-DEC-13:30 | 0.00 | 01-DEC-00:10 | 3713.46 | 16-DEC-13:30 | 3028.67 | 16-DEC-13:30 | 894.66 | 14-DEC-11:30 | 918.19 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.407570E+11 | 0.102665E+11 | 6579.07 | 0.297468E+11 | 0.110102E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.842986E+09 | 0.207729E+09 | 253.01 | 0.690287E+09 | 0.152699E+09 | 0.00 | 0.46 | 0.00 | 2918.21 | 2343.27 | 647.39 | 721.14 | 0.00 | |||||||
| Maximum of Months | 0.584527E+10 | 0.148761E+10 | 744.00 | 0.401638E+10 | 0.182889E+10 | 0.00 | 0.72 | 0.14 | 4699.22 | 3486.02 | 1383.55 | 1229.19 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.844679E+09 | 0.208151E+09 | 253.12 | 0.692042E+09 | 0.152637E+09 | 0.00 | 0.53 | 19-JAN-14:00 | 0.00 | 01-JAN-03:20 | 3416.42 | 19-JAN-14:00 | 2910.37 | 01-JAN-14:20 | 900.20 | 19-JAN-10:40 | 811.95 | 19-JAN-14:00 | 0.00 | 01-JAN-00:10 |
| February | 0.111105E+10 | 0.273311E+09 | 273.98 | 0.902058E+09 | 0.208990E+09 | 0.00 | 0.48 | 02-FEB-13:30 | 0.00 | 01-FEB-03:20 | 3018.37 | 24-FEB-14:00 | 2565.51 | 27-FEB-14:50 | 651.80 | 24-FEB-11:10 | 762.49 | 02-FEB-13:30 | 0.00 | 01-FEB-00:10 |
| March | 0.135377E+10 | 0.335208E+09 | 347.05 | 0.107723E+10 | 0.276538E+09 | 0.00 | 0.46 | 06-MAR-14:00 | 0.00 | 01-MAR-02:00 | 2929.42 | 06-MAR-14:00 | 2350.51 | 26-MAR-14:00 | 869.88 | 07-MAR-16:40 | 723.71 | 06-MAR-13:50 | 0.00 | 01-MAR-00:10 |
| April | 0.239272E+10 | 0.599883E+09 | 563.47 | 0.188753E+10 | 0.505195E+09 | 0.00 | 0.54 | 29-APR-16:03 | 0.00 | 01-APR-17:50 | 3486.26 | 29-APR-16:03 | 2737.80 | 28-APR-15:10 | 887.80 | 29-APR-16:03 | 889.85 | 29-APR-16:03 | 0.00 | 01-APR-00:10 |
| May | 0.506206E+10 | 0.128479E+10 | 744.00 | 0.366145E+10 | 0.140061E+10 | 0.00 | 0.53 | 07-MAY-14:00 | 0.08 | 01-MAY-00:10 | 3281.26 | 25-MAY-14:10 | 2705.51 | 07-MAY-14:00 | 996.85 | 26-MAY-11:00 | 895.20 | 07-MAY-14:00 | 0.00 | 01-MAY-00:10 |
| June | 0.517614E+10 | 0.132663E+10 | 720.00 | 0.376387E+10 | 0.141227E+10 | 0.00 | 0.56 | 28-JUN-15:10 | 0.06 | 07-JUN-05:10 | 3521.29 | 28-JUN-15:10 | 2757.08 | 10-JUN-16:20 | 916.46 | 29-JUN-15:30 | 952.97 | 28-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.585023E+10 | 0.148862E+10 | 744.00 | 0.402027E+10 | 0.182996E+10 | 0.00 | 0.61 | 22-JUL-16:10 | 0.14 | 15-JUL-04:00 | 3771.67 | 22-JUL-16:10 | 2961.30 | 22-JUL-16:03 | 1127.11 | 03-JUL-16:13 | 1061.50 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.571190E+10 | 0.144887E+10 | 744.00 | 0.399366E+10 | 0.171824E+10 | 0.00 | 0.60 | 03-AUG-16:02 | 0.09 | 17-AUG-03:00 | 3682.19 | 03-AUG-16:02 | 3081.73 | 30-AUG-16:03 | 1142.45 | 10-AUG-20:20 | 1030.68 | 03-AUG-16:02 | 0.00 | 01-AUG-00:10 |
| September | 0.518016E+10 | 0.129139E+10 | 720.00 | 0.356958E+10 | 0.161058E+10 | 0.00 | 0.70 | 10-SEP-13:30 | 0.10 | 08-SEP-00:10 | 4463.83 | 10-SEP-13:20 | 3388.93 | 10-SEP-14:00 | 1225.28 | 18-SEP-14:30 | 1222.47 | 10-SEP-13:40 | 0.00 | 01-SEP-00:10 |
| October | 0.460512E+10 | 0.114932E+10 | 664.83 | 0.338211E+10 | 0.122300E+10 | 0.00 | 0.72 | 08-OCT-14:00 | 0.00 | 01-OCT-05:15 | 4699.47 | 08-OCT-14:00 | 3490.14 | 09-OCT-14:00 | 1383.42 | 24-OCT-13:30 | 1228.85 | 08-OCT-14:00 | 0.00 | 01-OCT-00:10 |
| November | 0.207202E+10 | 0.514001E+09 | 465.94 | 0.167494E+10 | 0.397086E+09 | 0.00 | 0.60 | 02-NOV-14:10 | 0.00 | 05-NOV-02:30 | 3836.44 | 07-NOV-13:30 | 3081.77 | 02-NOV-14:10 | 1124.32 | 29-NOV-12:20 | 970.63 | 02-NOV-14:20 | 0.00 | 01-NOV-00:10 |
| December | 0.142478E+10 | 0.351799E+09 | 339.89 | 0.114468E+10 | 0.280106E+09 | 0.00 | 0.58 | 16-DEC-13:30 | 0.00 | 01-DEC-00:10 | 3720.93 | 16-DEC-13:30 | 3035.97 | 16-DEC-13:30 | 895.89 | 14-DEC-11:30 | 920.20 | 16-DEC-13:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.407846E+11 | 0.102720E+11 | 6580.29 | 0.297694E+11 | 0.110152E+11 | 0.00 | ||||||||||||||
| Minimum of Months | 0.844679E+09 | 0.208151E+09 | 253.12 | 0.692042E+09 | 0.152637E+09 | 0.00 | 0.46 | 0.00 | 2929.42 | 2350.51 | 651.80 | 723.71 | 0.00 | |||||||
| Maximum of Months | 0.585023E+10 | 0.148862E+10 | 744.00 | 0.402027E+10 | 0.182996E+10 | 0.00 | 0.72 | 0.14 | 4699.47 | 3490.14 | 1383.42 | 1228.85 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 281.98 | 132.16 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 266.79 | 110.83 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 172.96 | 96.08 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 147.48 | 60.97 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 142.34 | 11.98 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 144.48 | 10.01 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 151.69 | 5.50 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 173.25 | 10.81 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 194.11 | 17.68 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 266.73 | 37.20 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.67 | 87.81 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 289.05 | 117.68 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 210.08 | 57.95 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 142.34 | 5.50 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.67 | 132.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.90 | 32.89 | 28.01 | 76.09 | 95.63 | 0.00 | 0.00 | 0.00 |
| February | 68.91 | 34.83 | 34.08 | 91.27 | 78.67 | 0.00 | 0.00 | 0.00 |
| March | 68.05 | 30.11 | 37.94 | 96.17 | 64.49 | 0.00 | 0.00 | 0.00 |
| April | 84.39 | 38.76 | 45.64 | 136.87 | 39.15 | 0.00 | 0.00 | 0.00 |
| May | 70.30 | 22.88 | 47.42 | 142.43 | 7.92 | 0.00 | 0.00 | 0.00 |
| June | 78.17 | 27.47 | 50.69 | 161.16 | 6.52 | 0.00 | 0.00 | 0.00 |
| July | 71.22 | 19.74 | 51.49 | 148.94 | 3.71 | 0.00 | 0.00 | 0.00 |
| August | 72.01 | 21.96 | 50.05 | 147.91 | 7.03 | 0.00 | 0.00 | 0.00 |
| September | 66.39 | 22.79 | 43.60 | 128.37 | 11.54 | 0.00 | 0.00 | 0.00 |
| October | 67.80 | 29.23 | 38.57 | 123.76 | 25.13 | 0.00 | 0.00 | 0.00 |
| November | 58.20 | 29.24 | 28.96 | 84.18 | 63.00 | 0.00 | 0.00 | 0.00 |
| December | 56.00 | 29.78 | 26.22 | 74.15 | 83.13 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.49 | 28.24 | 40.25 | 117.71 | 40.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56.00 | 19.74 | 26.22 | 74.15 | 3.71 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.39 | 38.76 | 51.49 | 161.16 | 95.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.90 | 32.89 | 28.01 | 81.16 | 86.59 | 0.00 | 0.00 | 0.00 |
| February | 68.91 | 34.83 | 34.08 | 95.67 | 72.58 | 0.00 | 0.00 | 0.00 |
| March | 68.05 | 30.11 | 37.94 | 98.67 | 61.52 | 0.00 | 0.00 | 0.00 |
| April | 84.39 | 38.76 | 45.64 | 137.85 | 38.33 | 0.00 | 0.00 | 0.00 |
| May | 70.30 | 22.88 | 47.42 | 142.49 | 7.92 | 0.00 | 0.00 | 0.00 |
| June | 78.17 | 27.47 | 50.69 | 160.96 | 6.61 | 0.00 | 0.00 | 0.00 |
| July | 71.22 | 19.74 | 51.49 | 148.84 | 3.74 | 0.00 | 0.00 | 0.00 |
| August | 72.01 | 21.96 | 50.05 | 148.28 | 6.94 | 0.00 | 0.00 | 0.00 |
| September | 66.39 | 22.79 | 43.60 | 129.18 | 11.14 | 0.00 | 0.00 | 0.00 |
| October | 67.80 | 29.23 | 38.57 | 125.40 | 24.06 | 0.00 | 0.00 | 0.00 |
| November | 58.20 | 29.24 | 28.96 | 86.60 | 59.75 | 0.00 | 0.00 | 0.00 |
| December | 56.00 | 29.78 | 26.22 | 77.61 | 76.47 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.49 | 28.24 | 40.25 | 119.49 | 37.79 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56.00 | 19.74 | 26.22 | 77.61 | 3.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.39 | 38.76 | 51.49 | 160.96 | 86.59 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.88 | 139.88 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 34.56 | 116.14 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 50.85 | 97.08 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 78.79 | 59.15 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 135.89 | 11.56 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 159.17 | 9.59 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 154.79 | 5.61 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 137.81 | 10.30 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 108.77 | 17.03 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 86.32 | 37.27 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.19 | 94.70 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.46 | 123.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 86.44 | 59.83 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.88 | 5.61 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 159.17 | 139.88 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 276.64 | 142.28 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 262.63 | 119.93 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 167.41 | 107.19 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 138.98 | 75.86 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 124.40 | 32.80 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 125.71 | 31.10 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 127.08 | 26.92 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 153.63 | 34.39 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 176.00 | 43.77 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 251.99 | 62.96 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 285.08 | 105.87 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 282.68 | 131.29 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 197.33 | 75.97 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 124.40 | 26.92 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 285.08 | 142.28 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 57.57 | 29.44 | 28.14 | 64.06 | 99.61 | 0.00 | 0.00 | 0.00 |
| February | 63.70 | 30.63 | 33.07 | 77.33 | 81.74 | 0.00 | 0.00 | 0.00 |
| March | 75.12 | 36.17 | 38.94 | 101.14 | 68.69 | 0.00 | 0.00 | 0.00 |
| April | 82.63 | 37.43 | 45.20 | 125.90 | 47.06 | 0.00 | 0.00 | 0.00 |
| May | 85.00 | 36.88 | 48.12 | 154.20 | 20.44 | 0.00 | 0.00 | 0.00 |
| June | 86.16 | 34.18 | 51.98 | 161.57 | 19.32 | 0.00 | 0.00 | 0.00 |
| July | 83.13 | 30.46 | 52.67 | 153.33 | 16.91 | 0.00 | 0.00 | 0.00 |
| August | 76.57 | 26.30 | 50.26 | 140.60 | 21.32 | 0.00 | 0.00 | 0.00 |
| September | 67.72 | 23.24 | 44.48 | 117.12 | 27.90 | 0.00 | 0.00 | 0.00 |
| October | 67.16 | 28.42 | 38.74 | 110.35 | 41.38 | 0.00 | 0.00 | 0.00 |
| November | 59.33 | 30.25 | 29.08 | 76.49 | 72.24 | 0.00 | 0.00 | 0.00 |
| December | 46.75 | 21.20 | 25.54 | 52.64 | 91.76 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 70.93 | 30.37 | 40.55 | 111.41 | 50.54 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.75 | 21.20 | 25.54 | 52.64 | 16.91 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 86.16 | 37.43 | 52.67 | 161.57 | 99.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 57.57 | 29.44 | 28.14 | 71.11 | 82.50 | 0.00 | 0.00 | 0.00 |
| February | 63.70 | 30.63 | 33.07 | 83.35 | 68.74 | 0.00 | 0.00 | 0.00 |
| March | 75.12 | 36.17 | 38.94 | 106.90 | 58.35 | 0.00 | 0.00 | 0.00 |
| April | 82.63 | 37.43 | 45.20 | 132.70 | 36.85 | 0.00 | 0.00 | 0.00 |
| May | 85.00 | 36.88 | 48.12 | 167.02 | 7.44 | 0.00 | 0.00 | 0.00 |
| June | 86.16 | 34.18 | 51.98 | 174.74 | 6.17 | 0.00 | 0.00 | 0.00 |
| July | 83.13 | 30.46 | 52.67 | 169.94 | 3.51 | 0.00 | 0.00 | 0.00 |
| August | 76.57 | 26.30 | 50.26 | 154.93 | 6.56 | 0.00 | 0.00 | 0.00 |
| September | 67.72 | 23.24 | 44.48 | 130.59 | 10.73 | 0.00 | 0.00 | 0.00 |
| October | 67.16 | 28.42 | 38.74 | 121.83 | 22.86 | 0.00 | 0.00 | 0.00 |
| November | 59.33 | 30.25 | 29.08 | 83.60 | 56.31 | 0.00 | 0.00 | 0.00 |
| December | 46.75 | 21.20 | 25.54 | 59.10 | 74.51 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 70.93 | 30.37 | 40.55 | 121.53 | 36.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.75 | 21.20 | 25.54 | 59.10 | 3.51 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 86.16 | 37.43 | 52.67 | 174.74 | 82.50 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.50 | 139.43 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 34.17 | 115.62 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 50.17 | 96.86 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 78.29 | 58.85 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 135.37 | 11.52 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 158.79 | 9.50 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 154.33 | 5.61 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 137.58 | 10.18 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 108.60 | 16.87 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 86.12 | 37.00 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 35.78 | 94.62 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.37 | 122.32 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 86.08 | 59.57 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.50 | 5.61 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 158.79 | 139.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.51 | 143.13 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 34.12 | 119.01 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 50.13 | 100.30 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 78.74 | 60.21 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 137.00 | 11.29 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 160.76 | 9.20 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 156.74 | 5.24 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 139.99 | 9.52 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 110.51 | 16.10 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 87.74 | 36.57 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.28 | 95.77 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.25 | 126.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 87.14 | 60.75 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.51 | 5.24 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 160.76 | 143.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.50 | 143.12 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 34.10 | 119.00 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 50.10 | 100.31 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 78.72 | 60.21 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 136.97 | 11.30 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 160.74 | 9.20 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 156.72 | 5.24 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 139.98 | 9.52 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 110.50 | 16.09 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 87.73 | 36.56 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.26 | 95.78 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.26 | 126.21 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 87.13 | 60.74 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.50 | 5.24 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 160.74 | 143.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 279.70 | 136.92 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 264.80 | 114.74 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 171.65 | 99.68 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 147.42 | 61.91 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 143.39 | 11.76 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 146.01 | 9.62 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 153.61 | 5.16 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 175.34 | 10.07 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 195.69 | 16.82 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 267.96 | 36.60 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.67 | 88.34 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 287.86 | 120.86 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 210.31 | 59.08 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 143.39 | 5.16 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.67 | 136.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 279.28 | 137.59 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 264.43 | 115.25 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 171.18 | 100.44 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 146.92 | 62.53 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 142.38 | 12.47 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 144.94 | 10.29 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 152.23 | 5.70 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 174.21 | 10.76 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 194.78 | 17.72 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 267.19 | 37.48 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.22 | 89.00 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 287.44 | 121.61 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 209.56 | 59.78 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 142.38 | 5.70 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.22 | 137.59 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 280.12 | 132.60 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 262.89 | 114.52 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 169.07 | 100.82 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 144.63 | 63.90 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 141.10 | 12.48 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 143.91 | 10.13 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 152.33 | 5.10 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 174.82 | 9.53 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 195.15 | 15.84 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 267.14 | 35.32 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.10 | 86.42 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 288.23 | 116.17 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 209.10 | 58.27 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 141.10 | 5.10 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.10 | 132.60 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.90 | 32.89 | 28.01 | 75.18 | 95.99 | 0.00 | 0.00 | 0.00 |
| February | 68.91 | 34.83 | 34.08 | 89.26 | 81.46 | 0.00 | 0.00 | 0.00 |
| March | 68.05 | 30.11 | 37.94 | 93.74 | 67.78 | 0.00 | 0.00 | 0.00 |
| April | 84.39 | 38.76 | 45.64 | 134.74 | 41.07 | 0.00 | 0.00 | 0.00 |
| May | 70.30 | 22.88 | 47.42 | 141.46 | 8.27 | 0.00 | 0.00 | 0.00 |
| June | 78.17 | 27.47 | 50.69 | 160.50 | 6.61 | 0.00 | 0.00 | 0.00 |
| July | 71.22 | 19.74 | 51.49 | 149.11 | 3.47 | 0.00 | 0.00 | 0.00 |
| August | 72.01 | 21.96 | 50.05 | 148.83 | 6.20 | 0.00 | 0.00 | 0.00 |
| September | 66.39 | 22.79 | 43.60 | 129.12 | 10.39 | 0.00 | 0.00 | 0.00 |
| October | 67.80 | 29.23 | 38.57 | 124.33 | 23.90 | 0.00 | 0.00 | 0.00 |
| November | 58.20 | 29.24 | 28.96 | 84.14 | 62.04 | 0.00 | 0.00 | 0.00 |
| December | 56.00 | 29.78 | 26.22 | 73.87 | 82.11 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.49 | 28.24 | 40.25 | 117.14 | 40.56 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56.00 | 19.74 | 26.22 | 73.87 | 3.47 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.39 | 38.76 | 51.49 | 160.50 | 95.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.90 | 32.89 | 28.01 | 80.27 | 87.62 | 0.00 | 0.00 | 0.00 |
| February | 68.91 | 34.83 | 34.08 | 93.12 | 76.43 | 0.00 | 0.00 | 0.00 |
| March | 68.05 | 30.11 | 37.94 | 95.76 | 65.55 | 0.00 | 0.00 | 0.00 |
| April | 84.39 | 38.76 | 45.64 | 135.47 | 40.62 | 0.00 | 0.00 | 0.00 |
| May | 70.30 | 22.88 | 47.42 | 141.52 | 8.27 | 0.00 | 0.00 | 0.00 |
| June | 78.17 | 27.47 | 50.69 | 160.36 | 6.66 | 0.00 | 0.00 | 0.00 |
| July | 71.22 | 19.74 | 51.49 | 149.06 | 3.48 | 0.00 | 0.00 | 0.00 |
| August | 72.01 | 21.96 | 50.05 | 149.19 | 6.13 | 0.00 | 0.00 | 0.00 |
| September | 66.39 | 22.79 | 43.60 | 129.89 | 10.09 | 0.00 | 0.00 | 0.00 |
| October | 67.80 | 29.23 | 38.57 | 125.95 | 22.97 | 0.00 | 0.00 | 0.00 |
| November | 58.20 | 29.24 | 28.96 | 86.69 | 58.90 | 0.00 | 0.00 | 0.00 |
| December | 56.00 | 29.78 | 26.22 | 77.49 | 75.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.49 | 28.24 | 40.25 | 118.84 | 38.34 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56.00 | 19.74 | 26.22 | 77.49 | 3.48 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.39 | 38.76 | 51.49 | 160.36 | 87.62 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.24 | 141.47 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 32.06 | 122.48 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 47.51 | 103.61 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 76.04 | 62.75 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 134.70 | 12.01 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 158.62 | 9.62 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 155.42 | 5.19 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 139.64 | 9.02 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 110.28 | 15.35 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 87.68 | 35.47 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.72 | 93.24 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.71 | 122.14 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 86.05 | 60.70 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.24 | 5.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 158.62 | 141.47 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 279.29 | 132.16 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 262.29 | 114.02 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 168.25 | 100.56 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 144.19 | 63.56 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 140.61 | 12.39 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 143.53 | 10.01 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 151.90 | 5.06 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 174.59 | 9.40 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 194.97 | 15.67 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 266.94 | 35.05 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 292.67 | 86.12 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 287.97 | 115.56 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 208.66 | 58.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 140.61 | 5.06 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 292.67 | 132.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 57.57 | 29.44 | 28.14 | 65.73 | 92.67 | 0.00 | 0.00 | 0.00 |
| February | 63.70 | 30.63 | 33.07 | 77.37 | 77.87 | 0.00 | 0.00 | 0.00 |
| March | 75.12 | 36.17 | 38.94 | 101.73 | 64.43 | 0.00 | 0.00 | 0.00 |
| April | 82.63 | 37.43 | 45.20 | 129.55 | 39.41 | 0.00 | 0.00 | 0.00 |
| May | 85.00 | 36.88 | 48.12 | 165.76 | 7.70 | 0.00 | 0.00 | 0.00 |
| June | 86.16 | 34.18 | 51.98 | 174.22 | 6.13 | 0.00 | 0.00 | 0.00 |
| July | 83.13 | 30.46 | 52.67 | 170.16 | 3.19 | 0.00 | 0.00 | 0.00 |
| August | 76.57 | 26.30 | 50.26 | 155.47 | 5.81 | 0.00 | 0.00 | 0.00 |
| September | 67.72 | 23.24 | 44.48 | 130.51 | 9.96 | 0.00 | 0.00 | 0.00 |
| October | 67.16 | 28.42 | 38.74 | 120.64 | 22.71 | 0.00 | 0.00 | 0.00 |
| November | 59.33 | 30.25 | 29.08 | 81.07 | 58.56 | 0.00 | 0.00 | 0.00 |
| December | 46.75 | 21.20 | 25.54 | 55.58 | 80.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 70.93 | 30.37 | 40.55 | 119.22 | 38.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.75 | 21.20 | 25.54 | 55.58 | 3.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 86.16 | 37.43 | 52.67 | 174.22 | 92.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 57.57 | 29.44 | 28.14 | 70.18 | 83.39 | 0.00 | 0.00 | 0.00 |
| February | 63.70 | 30.63 | 33.07 | 80.82 | 72.45 | 0.00 | 0.00 | 0.00 |
| March | 75.12 | 36.17 | 38.94 | 103.69 | 62.17 | 0.00 | 0.00 | 0.00 |
| April | 82.63 | 37.43 | 45.20 | 130.25 | 38.96 | 0.00 | 0.00 | 0.00 |
| May | 85.00 | 36.88 | 48.12 | 165.83 | 7.69 | 0.00 | 0.00 | 0.00 |
| June | 86.16 | 34.18 | 51.98 | 174.07 | 6.18 | 0.00 | 0.00 | 0.00 |
| July | 83.13 | 30.46 | 52.67 | 170.11 | 3.20 | 0.00 | 0.00 | 0.00 |
| August | 76.57 | 26.30 | 50.26 | 155.83 | 5.74 | 0.00 | 0.00 | 0.00 |
| September | 67.72 | 23.24 | 44.48 | 131.29 | 9.65 | 0.00 | 0.00 | 0.00 |
| October | 67.16 | 28.42 | 38.74 | 122.34 | 21.74 | 0.00 | 0.00 | 0.00 |
| November | 59.33 | 30.25 | 29.08 | 83.65 | 55.53 | 0.00 | 0.00 | 0.00 |
| December | 46.75 | 21.20 | 25.54 | 59.02 | 73.89 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 70.93 | 30.37 | 40.55 | 120.82 | 36.52 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.75 | 21.20 | 25.54 | 59.02 | 3.20 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 86.16 | 37.43 | 52.67 | 174.07 | 83.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 23.78 | 140.85 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 31.58 | 122.01 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 46.74 | 103.42 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 75.56 | 62.43 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 134.22 | 11.91 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 158.25 | 9.50 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 155.00 | 5.16 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 139.42 | 8.89 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 110.11 | 15.18 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 87.46 | 35.16 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.20 | 93.12 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.56 | 121.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 85.66 | 60.40 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 23.78 | 5.16 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 158.25 | 140.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 23.73 | 145.22 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 31.72 | 125.52 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 47.23 | 106.17 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 76.81 | 62.73 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 136.41 | 11.42 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 160.66 | 9.04 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 157.55 | 4.82 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 141.60 | 8.48 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 111.79 | 14.75 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 88.81 | 35.32 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.49 | 95.35 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.28 | 126.36 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 86.85 | 61.76 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 23.73 | 4.82 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 160.66 | 145.22 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 23.71 | 145.19 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 31.69 | 125.52 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 47.18 | 106.19 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 76.79 | 62.72 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 136.39 | 11.42 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 160.65 | 9.03 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 157.53 | 4.82 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 141.59 | 8.48 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 111.79 | 14.75 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 88.80 | 35.31 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 36.47 | 95.36 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.29 | 126.26 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 86.83 | 61.75 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 23.71 | 4.82 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 160.65 | 145.19 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 277.57 | 137.84 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 261.44 | 117.65 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 168.41 | 103.50 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 145.38 | 63.81 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 142.79 | 11.88 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 145.92 | 9.51 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 154.50 | 4.72 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 176.74 | 8.99 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 196.57 | 15.27 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 268.17 | 35.10 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 292.86 | 87.41 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 286.76 | 119.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 209.50 | 59.33 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 142.79 | 4.72 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 292.86 | 137.84 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 277.54 | 137.84 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 261.42 | 117.64 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 168.37 | 103.50 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 145.37 | 63.80 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 142.78 | 11.88 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 145.91 | 9.51 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 154.48 | 4.72 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 176.73 | 8.99 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 196.56 | 15.27 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 268.16 | 35.09 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 292.85 | 87.41 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 286.76 | 119.95 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 209.48 | 59.33 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 142.78 | 4.72 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 292.85 | 137.84 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 281.47 | 120.62 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 263.79 | 104.36 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 169.45 | 91.31 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 142.64 | 59.41 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 136.36 | 12.37 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 138.69 | 10.12 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 146.99 | 5.04 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 169.57 | 9.41 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 190.67 | 15.57 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 263.56 | 32.96 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.67 | 78.28 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 289.21 | 104.76 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 206.88 | 53.41 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 136.36 | 5.04 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.67 | 120.62 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.90 | 32.89 | 28.01 | 74.53 | 86.51 | 0.00 | 0.00 | 0.00 |
| February | 68.91 | 34.83 | 34.08 | 88.64 | 73.50 | 0.00 | 0.00 | 0.00 |
| March | 68.05 | 30.11 | 37.94 | 93.29 | 60.80 | 0.00 | 0.00 | 0.00 |
| April | 84.39 | 38.76 | 45.64 | 133.04 | 37.85 | 0.00 | 0.00 | 0.00 |
| May | 70.30 | 22.88 | 47.42 | 138.25 | 8.17 | 0.00 | 0.00 | 0.00 |
| June | 78.17 | 27.47 | 50.69 | 156.84 | 6.55 | 0.00 | 0.00 | 0.00 |
| July | 71.22 | 19.74 | 51.49 | 145.41 | 3.41 | 0.00 | 0.00 | 0.00 |
| August | 72.01 | 21.96 | 50.05 | 145.28 | 6.10 | 0.00 | 0.00 | 0.00 |
| September | 66.39 | 22.79 | 43.60 | 126.15 | 10.17 | 0.00 | 0.00 | 0.00 |
| October | 67.80 | 29.23 | 38.57 | 121.86 | 22.13 | 0.00 | 0.00 | 0.00 |
| November | 58.20 | 29.24 | 28.96 | 83.16 | 55.21 | 0.00 | 0.00 | 0.00 |
| December | 56.00 | 29.78 | 26.22 | 73.19 | 73.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.49 | 28.24 | 40.25 | 115.08 | 36.77 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56.00 | 19.74 | 26.22 | 73.19 | 3.41 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.39 | 38.76 | 51.49 | 156.84 | 86.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 60.90 | 32.89 | 28.01 | 80.31 | 81.69 | 0.00 | 0.00 | 0.00 |
| February | 68.91 | 34.83 | 34.08 | 93.43 | 70.02 | 0.00 | 0.00 | 0.00 |
| March | 68.05 | 30.11 | 37.94 | 95.95 | 59.17 | 0.00 | 0.00 | 0.00 |
| April | 84.39 | 38.76 | 45.64 | 134.23 | 37.32 | 0.00 | 0.00 | 0.00 |
| May | 70.30 | 22.88 | 47.42 | 138.33 | 8.18 | 0.00 | 0.00 | 0.00 |
| June | 78.17 | 27.47 | 50.69 | 156.65 | 6.60 | 0.00 | 0.00 | 0.00 |
| July | 71.22 | 19.74 | 51.49 | 145.32 | 3.42 | 0.00 | 0.00 | 0.00 |
| August | 72.01 | 21.96 | 50.05 | 145.77 | 6.05 | 0.00 | 0.00 | 0.00 |
| September | 66.39 | 22.79 | 43.60 | 127.23 | 9.93 | 0.00 | 0.00 | 0.00 |
| October | 67.80 | 29.23 | 38.57 | 124.31 | 21.16 | 0.00 | 0.00 | 0.00 |
| November | 58.20 | 29.24 | 28.96 | 87.64 | 51.81 | 0.00 | 0.00 | 0.00 |
| December | 56.00 | 29.78 | 26.22 | 77.97 | 68.84 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.49 | 28.24 | 40.25 | 117.36 | 35.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56.00 | 19.74 | 26.22 | 77.97 | 3.42 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 84.39 | 38.76 | 51.49 | 156.65 | 81.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.47 | 132.39 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 32.82 | 112.77 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 48.15 | 93.93 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 74.81 | 57.97 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 130.07 | 11.96 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 153.26 | 9.58 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 150.11 | 5.14 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 134.72 | 8.92 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 106.45 | 15.16 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 85.38 | 32.70 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 38.20 | 82.21 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 26.49 | 111.29 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 84.06 | 55.87 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.47 | 5.14 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 153.26 | 132.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 280.18 | 119.63 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 262.64 | 103.33 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 167.89 | 90.57 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 141.59 | 58.67 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 135.64 | 12.16 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 138.13 | 9.88 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 146.40 | 4.94 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 169.23 | 9.20 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 190.39 | 15.29 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 263.14 | 32.47 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 292.57 | 77.60 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 288.58 | 103.83 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 206.08 | 52.86 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 135.64 | 4.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 292.57 | 119.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 57.57 | 29.44 | 28.14 | 66.80 | 84.69 | 0.00 | 0.00 | 0.00 |
| February | 63.70 | 30.63 | 33.07 | 78.17 | 71.15 | 0.00 | 0.00 | 0.00 |
| March | 75.12 | 36.17 | 38.94 | 102.19 | 58.40 | 0.00 | 0.00 | 0.00 |
| April | 82.63 | 37.43 | 45.20 | 128.40 | 36.74 | 0.00 | 0.00 | 0.00 |
| May | 85.00 | 36.88 | 48.12 | 162.23 | 7.56 | 0.00 | 0.00 | 0.00 |
| June | 86.16 | 34.18 | 51.98 | 170.45 | 6.05 | 0.00 | 0.00 | 0.00 |
| July | 83.13 | 30.46 | 52.67 | 166.41 | 3.11 | 0.00 | 0.00 | 0.00 |
| August | 76.57 | 26.30 | 50.26 | 151.82 | 5.68 | 0.00 | 0.00 | 0.00 |
| September | 67.72 | 23.24 | 44.48 | 127.42 | 9.70 | 0.00 | 0.00 | 0.00 |
| October | 67.16 | 28.42 | 38.74 | 118.21 | 21.09 | 0.00 | 0.00 | 0.00 |
| November | 59.33 | 30.25 | 29.08 | 81.43 | 53.19 | 0.00 | 0.00 | 0.00 |
| December | 46.75 | 21.20 | 25.54 | 56.20 | 72.93 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 70.93 | 30.37 | 40.55 | 117.70 | 35.67 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.75 | 21.20 | 25.54 | 56.20 | 3.11 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 86.16 | 37.43 | 52.67 | 170.45 | 84.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 57.57 | 29.44 | 28.14 | 70.95 | 77.98 | 0.00 | 0.00 | 0.00 |
| February | 63.70 | 30.63 | 33.07 | 82.02 | 66.63 | 0.00 | 0.00 | 0.00 |
| March | 75.12 | 36.17 | 38.94 | 104.58 | 56.43 | 0.00 | 0.00 | 0.00 |
| April | 82.63 | 37.43 | 45.20 | 129.49 | 36.14 | 0.00 | 0.00 | 0.00 |
| May | 85.00 | 36.88 | 48.12 | 162.31 | 7.57 | 0.00 | 0.00 | 0.00 |
| June | 86.16 | 34.18 | 51.98 | 170.26 | 6.10 | 0.00 | 0.00 | 0.00 |
| July | 83.13 | 30.46 | 52.67 | 166.33 | 3.12 | 0.00 | 0.00 | 0.00 |
| August | 76.57 | 26.30 | 50.26 | 152.31 | 5.63 | 0.00 | 0.00 | 0.00 |
| September | 67.72 | 23.24 | 44.48 | 128.50 | 9.45 | 0.00 | 0.00 | 0.00 |
| October | 67.16 | 28.42 | 38.74 | 120.75 | 19.98 | 0.00 | 0.00 | 0.00 |
| November | 59.33 | 30.25 | 29.08 | 85.54 | 49.13 | 0.00 | 0.00 | 0.00 |
| December | 46.75 | 21.20 | 25.54 | 60.17 | 67.41 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 70.93 | 30.37 | 40.55 | 119.64 | 33.62 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46.75 | 21.20 | 25.54 | 60.17 | 3.12 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 86.16 | 37.43 | 52.67 | 170.26 | 77.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 23.60 | 131.23 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 31.82 | 111.58 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 46.67 | 93.11 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 73.69 | 57.18 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 129.39 | 11.74 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 152.74 | 9.36 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 149.55 | 5.05 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 134.40 | 8.71 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 106.17 | 14.88 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 84.96 | 32.06 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 37.02 | 81.21 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 25.93 | 109.92 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 83.31 | 55.21 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 23.60 | 5.05 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 152.74 | 131.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.48 | 134.14 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 32.87 | 114.51 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 48.46 | 95.74 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 75.77 | 58.71 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 132.29 | 11.56 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 155.88 | 9.15 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 152.74 | 4.89 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 137.24 | 8.55 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 108.46 | 14.79 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 86.99 | 32.84 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 38.34 | 83.69 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 26.64 | 112.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 85.34 | 56.49 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.48 | 4.89 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 155.88 | 134.14 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 33.86 | 0.00 | 33.86 | 24.42 | 134.06 | 0.00 | 0.00 | 0.00 |
| February | 39.94 | 0.00 | 39.94 | 32.80 | 114.43 | 0.00 | 0.00 | 0.00 |
| March | 46.35 | 0.00 | 46.34 | 48.35 | 95.69 | 0.00 | 0.00 | 0.00 |
| April | 54.83 | 0.32 | 54.51 | 75.70 | 58.66 | 0.00 | 0.00 | 0.00 |
| May | 62.05 | 2.34 | 59.72 | 132.26 | 11.54 | 0.00 | 0.00 | 0.00 |
| June | 70.35 | 4.79 | 65.56 | 155.86 | 9.14 | 0.00 | 0.00 | 0.00 |
| July | 68.32 | 2.55 | 65.77 | 152.71 | 4.89 | 0.00 | 0.00 | 0.00 |
| August | 61.44 | 0.63 | 60.81 | 137.22 | 8.54 | 0.00 | 0.00 | 0.00 |
| September | 52.90 | 0.01 | 52.89 | 108.44 | 14.78 | 0.00 | 0.00 | 0.00 |
| October | 45.95 | 0.00 | 45.95 | 86.97 | 32.79 | 0.00 | 0.00 | 0.00 |
| November | 34.88 | 0.00 | 34.88 | 38.26 | 83.61 | 0.00 | 0.00 | 0.00 |
| December | 31.47 | 0.00 | 31.47 | 26.60 | 112.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 50.25 | 0.89 | 49.36 | 85.29 | 56.44 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 31.47 | 0.00 | 31.47 | 24.42 | 4.89 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70.35 | 4.79 | 65.77 | 155.86 | 134.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 280.27 | 123.97 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 262.90 | 107.13 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 169.27 | 93.67 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 143.50 | 60.21 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 138.57 | 11.96 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 141.27 | 9.66 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 149.67 | 4.79 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 172.04 | 9.04 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 192.57 | 15.22 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 264.83 | 33.26 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.19 | 80.44 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 288.45 | 107.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 207.76 | 54.47 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 138.57 | 4.79 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.19 | 123.97 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 193.76 | 137.63 | 56.13 | 280.18 | 123.90 | 0.00 | 0.00 | 0.00 |
| February | 178.74 | 116.14 | 62.61 | 262.82 | 107.05 | 0.00 | 0.00 | 0.00 |
| March | 111.84 | 49.67 | 62.17 | 169.17 | 93.62 | 0.00 | 0.00 | 0.00 |
| April | 85.87 | 21.55 | 64.32 | 143.44 | 60.17 | 0.00 | 0.00 | 0.00 |
| May | 64.39 | 2.92 | 61.47 | 138.54 | 11.95 | 0.00 | 0.00 | 0.00 |
| June | 63.46 | 0.66 | 62.80 | 141.24 | 9.65 | 0.00 | 0.00 | 0.00 |
| July | 66.40 | 1.25 | 65.15 | 149.65 | 4.78 | 0.00 | 0.00 | 0.00 |
| August | 77.41 | 8.70 | 68.71 | 172.03 | 9.03 | 0.00 | 0.00 | 0.00 |
| September | 94.94 | 25.95 | 68.99 | 192.56 | 15.20 | 0.00 | 0.00 | 0.00 |
| October | 142.72 | 73.10 | 69.63 | 264.81 | 33.23 | 0.00 | 0.00 | 0.00 |
| November | 185.68 | 128.07 | 57.62 | 293.13 | 80.40 | 0.00 | 0.00 | 0.00 |
| December | 190.91 | 137.01 | 53.89 | 288.41 | 107.58 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 121.02 | 58.24 | 62.78 | 207.72 | 54.43 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63.46 | 0.66 | 53.89 | 138.54 | 4.78 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 193.76 | 137.63 | 69.63 | 293.13 | 123.90 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 13.81 | 7.06 | 6.75 | 16.00 | 21.78 | 212.83 | 0.00 | 0.00 |
| February | 15.28 | 7.35 | 7.93 | 18.60 | 18.71 | 221.83 | 0.00 | 0.00 |
| March | 18.02 | 8.68 | 9.34 | 23.93 | 15.98 | 228.83 | 0.00 | 0.00 |
| April | 19.83 | 8.98 | 10.85 | 29.59 | 10.74 | 325.67 | 0.00 | 0.00 |
| May | 20.40 | 8.85 | 11.55 | 36.60 | 3.38 | 302.50 | 0.00 | 0.00 |
| June | 20.67 | 8.20 | 12.47 | 38.53 | 2.96 | 280.67 | 0.00 | 0.00 |
| July | 19.95 | 7.31 | 12.64 | 37.24 | 1.97 | 255.50 | 0.00 | 0.00 |
| August | 18.37 | 6.31 | 12.06 | 34.03 | 2.78 | 296.33 | 0.00 | 0.00 |
| September | 16.25 | 5.58 | 10.67 | 28.68 | 4.03 | 334.50 | 0.00 | 0.00 |
| October | 16.12 | 6.82 | 9.30 | 26.95 | 6.94 | 276.50 | 0.00 | 0.00 |
| November | 14.24 | 7.26 | 6.98 | 19.22 | 14.54 | 310.83 | 0.00 | 0.00 |
| December | 11.22 | 5.09 | 6.13 | 13.37 | 19.21 | 262.50 | 0.00 | 0.00 |
| Annual Sum or Average | 17.02 | 7.29 | 9.73 | 26.94 | 10.21 | 3308.50 | 0.00 | 0.00 |
| Minimum of Months | 11.22 | 5.09 | 6.13 | 13.37 | 1.97 | 212.83 | 0.00 | 0.00 |
| Maximum of Months | 20.67 | 8.98 | 12.64 | 38.53 | 21.78 | 334.50 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.14 | 21.04 | 20.11 | 47.73 | 65.87 | 22.67 | 0.00 | 0.00 |
| February | 45.52 | 21.89 | 23.63 | 56.10 | 55.37 | 37.00 | 0.00 | 0.00 |
| March | 53.68 | 25.85 | 27.83 | 72.18 | 47.56 | 24.83 | 0.00 | 0.00 |
| April | 59.05 | 26.75 | 32.30 | 88.72 | 32.09 | 50.50 | 0.00 | 0.00 |
| May | 60.74 | 26.36 | 34.39 | 108.19 | 11.30 | 109.50 | 0.00 | 0.00 |
| June | 61.57 | 24.43 | 37.15 | 113.21 | 10.34 | 115.83 | 0.00 | 0.00 |
| July | 59.41 | 21.77 | 37.64 | 108.74 | 7.77 | 148.33 | 0.00 | 0.00 |
| August | 54.72 | 18.80 | 35.92 | 99.03 | 10.57 | 132.33 | 0.00 | 0.00 |
| September | 48.40 | 16.61 | 31.79 | 83.58 | 14.57 | 120.50 | 0.00 | 0.00 |
| October | 48.00 | 20.31 | 27.69 | 78.70 | 23.59 | 90.33 | 0.00 | 0.00 |
| November | 42.40 | 21.62 | 20.78 | 55.61 | 46.62 | 44.83 | 0.00 | 0.00 |
| December | 33.41 | 15.15 | 18.25 | 38.94 | 60.27 | 24.17 | 0.00 | 0.00 |
| Annual Sum or Average | 50.69 | 21.71 | 28.98 | 79.35 | 32.04 | 920.83 | 0.00 | 0.00 |
| Minimum of Months | 33.41 | 15.15 | 18.25 | 38.94 | 7.77 | 22.67 | 0.00 | 0.00 |
| Maximum of Months | 61.57 | 26.75 | 37.64 | 113.21 | 65.87 | 148.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 13.81 | 7.06 | 6.75 | 15.04 | 24.32 | 394.50 | 0.00 | 0.00 |
| February | 15.28 | 7.35 | 7.93 | 17.63 | 20.86 | 322.83 | 0.00 | 0.00 |
| March | 18.02 | 8.68 | 9.34 | 23.06 | 17.88 | 305.50 | 0.00 | 0.00 |
| April | 19.83 | 8.98 | 10.85 | 29.22 | 11.44 | 386.00 | 0.00 | 0.00 |
| May | 20.40 | 8.85 | 11.55 | 37.24 | 3.29 | 309.50 | 0.00 | 0.00 |
| June | 20.67 | 8.20 | 12.47 | 39.26 | 2.85 | 277.67 | 0.00 | 0.00 |
| July | 19.95 | 7.31 | 12.64 | 38.02 | 1.87 | 231.33 | 0.00 | 0.00 |
| August | 18.37 | 6.31 | 12.06 | 34.75 | 2.70 | 286.67 | 0.00 | 0.00 |
| September | 16.25 | 5.58 | 10.67 | 29.19 | 4.03 | 345.17 | 0.00 | 0.00 |
| October | 16.12 | 6.82 | 9.30 | 27.09 | 7.30 | 324.67 | 0.00 | 0.00 |
| November | 14.24 | 7.26 | 6.98 | 18.28 | 16.22 | 418.67 | 0.00 | 0.00 |
| December | 11.22 | 5.09 | 6.13 | 12.52 | 21.74 | 431.67 | 0.00 | 0.00 |
| Annual Sum or Average | 17.02 | 7.29 | 9.73 | 26.83 | 11.16 | 4034.17 | 0.00 | 0.00 |
| Minimum of Months | 11.22 | 5.09 | 6.13 | 12.52 | 1.87 | 231.33 | 0.00 | 0.00 |
| Maximum of Months | 20.67 | 8.98 | 12.64 | 39.26 | 24.32 | 431.67 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.755248E+09 | 0.353974E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.645419E+09 | 0.268128E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.463262E+09 | 0.257335E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.382270E+09 | 0.158040E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.381231E+09 | 32097823.48 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.374503E+09 | 25935049.10 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.406287E+09 | 14741985.43 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.464025E+09 | 28965248.08 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.503135E+09 | 45820486.23 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.714414E+09 | 99636868.03 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.761183E+09 | 0.227603E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.774182E+09 | 0.315200E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.662516E+10 | 0.182748E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.374503E+09 | 14741985.43 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.774182E+09 | 0.353974E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.163106E+09 | 88094626.44 | 75011424.02 | 0.203788E+09 | 0.256145E+09 |
| February | 0.166715E+09 | 84264227.65 | 82450954.55 | 0.220801E+09 | 0.190317E+09 |
| March | 0.182253E+09 | 80642087.83 | 0.101611E+09 | 0.257580E+09 | 0.172736E+09 |
| April | 0.218751E+09 | 0.100464E+09 | 0.118287E+09 | 0.354767E+09 | 0.101481E+09 |
| May | 0.188304E+09 | 61283070.74 | 0.127021E+09 | 0.381479E+09 | 21214993.96 |
| June | 0.202615E+09 | 71213815.09 | 0.131401E+09 | 0.417717E+09 | 16889158.82 |
| July | 0.190768E+09 | 52858399.85 | 0.137909E+09 | 0.398929E+09 | 9932599.75 |
| August | 0.192879E+09 | 58813639.82 | 0.134066E+09 | 0.396172E+09 | 18822331.24 |
| September | 0.172085E+09 | 59083595.57 | 0.113002E+09 | 0.332734E+09 | 29915353.72 |
| October | 0.181583E+09 | 78285677.91 | 0.103297E+09 | 0.331487E+09 | 67302270.04 |
| November | 0.150867E+09 | 75789925.26 | 75076667.81 | 0.218185E+09 | 0.163293E+09 |
| December | 0.149994E+09 | 79754632.26 | 70238955.06 | 0.198609E+09 | 0.222662E+09 |
| Annual Sum or Average | 0.215992E+10 | 0.890548E+09 | 0.126937E+10 | 0.371225E+10 | 0.127071E+10 |
| Minimum of Months | 0.149994E+09 | 52858399.85 | 70238955.06 | 0.198609E+09 | 9932599.75 |
| Maximum of Months | 0.218751E+09 | 0.100464E+09 | 0.137909E+09 | 0.417717E+09 | 0.256145E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.163106E+09 | 88094626.44 | 75011424.02 | 0.217389E+09 | 0.231912E+09 |
| February | 0.166715E+09 | 84264227.65 | 82450954.55 | 0.231441E+09 | 0.175597E+09 |
| March | 0.182253E+09 | 80642087.83 | 0.101611E+09 | 0.264278E+09 | 0.164773E+09 |
| April | 0.218751E+09 | 0.100464E+09 | 0.118287E+09 | 0.357304E+09 | 99357949.02 |
| May | 0.188304E+09 | 61283070.74 | 0.127021E+09 | 0.381649E+09 | 21219755.85 |
| June | 0.202615E+09 | 71213815.09 | 0.131401E+09 | 0.417211E+09 | 17131593.12 |
| July | 0.190768E+09 | 52858399.85 | 0.137909E+09 | 0.398657E+09 | 10017562.41 |
| August | 0.192879E+09 | 58813639.82 | 0.134066E+09 | 0.397153E+09 | 18598545.94 |
| September | 0.172085E+09 | 59083595.57 | 0.113002E+09 | 0.334832E+09 | 28875679.22 |
| October | 0.181583E+09 | 78285677.91 | 0.103297E+09 | 0.335865E+09 | 64444289.56 |
| November | 0.150867E+09 | 75789925.26 | 75076667.81 | 0.224474E+09 | 0.154875E+09 |
| December | 0.149994E+09 | 79754632.26 | 70238955.06 | 0.207870E+09 | 0.204807E+09 |
| Annual Sum or Average | 0.215992E+10 | 0.890548E+09 | 0.126937E+10 | 0.376812E+10 | 0.119161E+10 |
| Minimum of Months | 0.149994E+09 | 52858399.85 | 70238955.06 | 0.207870E+09 | 10017562.41 |
| Maximum of Months | 0.218751E+09 | 0.100464E+09 | 0.137909E+09 | 0.417211E+09 | 0.231912E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 66626134.49 | 0.374652E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 83611845.77 | 0.280969E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.136210E+09 | 0.260032E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.204214E+09 | 0.153309E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.363977E+09 | 30956823.59 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.412575E+09 | 24857522.29 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.414597E+09 | 15013265.27 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.369102E+09 | 27585066.85 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.281920E+09 | 44140778.42 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.231198E+09 | 99834094.82 |
| November | 90416797.23 | 0.00 | 90416797.23 | 93797136.93 | 0.245464E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 68194297.14 | 0.329951E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.272602E+10 | 0.188676E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 66626134.49 | 15013265.27 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.414597E+09 | 0.374652E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.740944E+09 | 0.381071E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.635353E+09 | 0.290136E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.448400E+09 | 0.287090E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.360223E+09 | 0.196637E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.333205E+09 | 87854009.96 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.325848E+09 | 80613094.14 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.340363E+09 | 72102925.98 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.411482E+09 | 92097981.64 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.456183E+09 | 0.113447E+09 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.674938E+09 | 0.168620E+09 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.738937E+09 | 0.274409E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.757120E+09 | 0.351657E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.622300E+10 | 0.239574E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.325848E+09 | 72102925.98 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.757120E+09 | 0.381071E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.154199E+09 | 78839041.99 | 75359594.22 | 0.171568E+09 | 0.266808E+09 |
| February | 0.154100E+09 | 74108536.14 | 79991098.96 | 0.187068E+09 | 0.197736E+09 |
| March | 0.201192E+09 | 96886895.73 | 0.104305E+09 | 0.270905E+09 | 0.183982E+09 |
| April | 0.214172E+09 | 97019692.19 | 0.117153E+09 | 0.326337E+09 | 0.121991E+09 |
| May | 0.227657E+09 | 98785597.66 | 0.128871E+09 | 0.412998E+09 | 54756099.82 |
| June | 0.223323E+09 | 88598292.67 | 0.134725E+09 | 0.418792E+09 | 50065835.81 |
| July | 0.222652E+09 | 81593955.70 | 0.141058E+09 | 0.410668E+09 | 45298795.83 |
| August | 0.205074E+09 | 70448943.86 | 0.134625E+09 | 0.376595E+09 | 57103898.52 |
| September | 0.175533E+09 | 60235005.99 | 0.115298E+09 | 0.303564E+09 | 72310183.85 |
| October | 0.179884E+09 | 76119207.32 | 0.103765E+09 | 0.295549E+09 | 0.110843E+09 |
| November | 0.153779E+09 | 78414852.08 | 75364185.52 | 0.198249E+09 | 0.187242E+09 |
| December | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.140981E+09 | 0.245767E+09 |
| Annual Sum or Average | 0.223677E+10 | 0.957839E+09 | 0.127893E+10 | 0.351328E+10 | 0.159390E+10 |
| Minimum of Months | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.140981E+09 | 45298795.83 |
| Maximum of Months | 0.227657E+09 | 98785597.66 | 0.141058E+09 | 0.418792E+09 | 0.266808E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.154199E+09 | 78839041.99 | 75359594.22 | 0.190448E+09 | 0.220959E+09 |
| February | 0.154100E+09 | 74108536.14 | 79991098.96 | 0.201638E+09 | 0.166288E+09 |
| March | 0.201192E+09 | 96886895.73 | 0.104305E+09 | 0.286329E+09 | 0.156288E+09 |
| April | 0.214172E+09 | 97019692.19 | 0.117153E+09 | 0.343953E+09 | 95503477.42 |
| May | 0.227657E+09 | 98785597.66 | 0.128871E+09 | 0.447334E+09 | 19938087.48 |
| June | 0.223323E+09 | 88598292.67 | 0.134725E+09 | 0.452923E+09 | 15999618.41 |
| July | 0.222652E+09 | 81593955.70 | 0.141058E+09 | 0.455174E+09 | 9391075.36 |
| August | 0.205074E+09 | 70448943.86 | 0.134625E+09 | 0.414978E+09 | 17574897.44 |
| September | 0.175533E+09 | 60235005.99 | 0.115298E+09 | 0.338489E+09 | 27810026.79 |
| October | 0.179884E+09 | 76119207.32 | 0.103765E+09 | 0.326319E+09 | 61231862.99 |
| November | 0.153779E+09 | 78414852.08 | 75364185.52 | 0.216699E+09 | 0.145947E+09 |
| December | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.158300E+09 | 0.199559E+09 |
| Annual Sum or Average | 0.223677E+10 | 0.957839E+09 | 0.127893E+10 | 0.383258E+10 | 0.113649E+10 |
| Minimum of Months | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.158300E+09 | 9391075.36 |
| Maximum of Months | 0.227657E+09 | 98785597.66 | 0.141058E+09 | 0.455174E+09 | 0.220959E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 65611710.56 | 0.373458E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 82671604.35 | 0.279718E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.134389E+09 | 0.259422E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.202917E+09 | 0.152533E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.362588E+09 | 30845181.00 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.411579E+09 | 24621464.32 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.413366E+09 | 15013004.00 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.368492E+09 | 27273098.68 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.281503E+09 | 43725791.09 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.230676E+09 | 99096402.62 |
| November | 90416797.23 | 0.00 | 90416797.23 | 92753702.77 | 0.245267E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 67957980.69 | 0.327622E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.271450E+10 | 0.187859E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 65611710.56 | 15013004.00 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.413366E+09 | 0.373458E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 65654953.93 | 0.383365E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 82542625.91 | 0.287905E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.134280E+09 | 0.268636E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.204092E+09 | 0.156058E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.366930E+09 | 30250250.47 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.416690E+09 | 23839259.41 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.419815E+09 | 14039405.20 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.374949E+09 | 25501484.95 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.286435E+09 | 41727019.94 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.235000E+09 | 97958953.62 |
| November | 90416797.23 | 0.00 | 90416797.23 | 94035529.80 | 0.248245E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 67633042.59 | 0.338271E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.274806E+10 | 0.191580E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 65654953.93 | 14039405.20 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.419815E+09 | 0.383365E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 65615952.49 | 0.383326E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 82497433.92 | 0.287879E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.134183E+09 | 0.268660E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.204031E+09 | 0.156051E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.366873E+09 | 30256378.94 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.416649E+09 | 23837018.35 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.419761E+09 | 14045455.01 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.374925E+09 | 25493443.84 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.286421E+09 | 41714250.13 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.234982E+09 | 97932797.26 |
| November | 90416797.23 | 0.00 | 90416797.23 | 93986919.70 | 0.248271E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 67652555.36 | 0.338046E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.274758E+10 | 0.191551E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 65615952.49 | 14045455.01 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.419761E+09 | 0.383326E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.749159E+09 | 0.366735E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.640609E+09 | 0.277570E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.459757E+09 | 0.266995E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.382115E+09 | 0.160458E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.384052E+09 | 31488841.11 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.378467E+09 | 24934308.19 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.411441E+09 | 13811213.41 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.469619E+09 | 26966164.20 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.507236E+09 | 43591443.74 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.717705E+09 | 98025020.45 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.761190E+09 | 0.228988E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.770999E+09 | 0.323698E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.663235E+10 | 0.186326E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.378467E+09 | 13811213.41 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.770999E+09 | 0.366735E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.748026E+09 | 0.368525E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.639721E+09 | 0.278809E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.458483E+09 | 0.269026E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.380812E+09 | 0.162082E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.381342E+09 | 33388531.68 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.375673E+09 | 26678533.39 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.407734E+09 | 15256484.63 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.466606E+09 | 28813989.10 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.504863E+09 | 45931829.43 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.715650E+09 | 0.100394E+09 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.760035E+09 | 0.230695E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.769872E+09 | 0.325711E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.660882E+10 | 0.188531E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.375673E+09 | 15256484.63 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.769872E+09 | 0.368525E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.750260E+09 | 0.355146E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.635988E+09 | 0.277050E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.452846E+09 | 0.270030E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.374872E+09 | 0.165631E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.377926E+09 | 33419947.13 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.373009E+09 | 26265741.61 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.408006E+09 | 13656572.15 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.468243E+09 | 25522498.89 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.505819E+09 | 41069437.14 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.715517E+09 | 94612184.68 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.759725E+09 | 0.224008E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.771984E+09 | 0.311161E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.659420E+10 | 0.183757E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.373009E+09 | 13656572.15 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.771984E+09 | 0.355146E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.163106E+09 | 88094626.44 | 75011424.02 | 0.201363E+09 | 0.257104E+09 |
| February | 0.166715E+09 | 84264227.65 | 82450954.55 | 0.215927E+09 | 0.197071E+09 |
| March | 0.182253E+09 | 80642087.83 | 0.101611E+09 | 0.251080E+09 | 0.181534E+09 |
| April | 0.218751E+09 | 0.100464E+09 | 0.118287E+09 | 0.349237E+09 | 0.106453E+09 |
| May | 0.188304E+09 | 61283070.74 | 0.127021E+09 | 0.378882E+09 | 22153558.96 |
| June | 0.202615E+09 | 71213815.09 | 0.131401E+09 | 0.416024E+09 | 17130711.00 |
| July | 0.190768E+09 | 52858399.85 | 0.137909E+09 | 0.399385E+09 | 9288705.11 |
| August | 0.192879E+09 | 58813639.82 | 0.134066E+09 | 0.398637E+09 | 16613478.59 |
| September | 0.172085E+09 | 59083595.57 | 0.113002E+09 | 0.334685E+09 | 26943111.66 |
| October | 0.181583E+09 | 78285677.91 | 0.103297E+09 | 0.333001E+09 | 64016924.32 |
| November | 0.150867E+09 | 75789925.26 | 75076667.81 | 0.218086E+09 | 0.160820E+09 |
| December | 0.149994E+09 | 79754632.26 | 70238955.06 | 0.197862E+09 | 0.219924E+09 |
| Annual Sum or Average | 0.215992E+10 | 0.890548E+09 | 0.126937E+10 | 0.369417E+10 | 0.127905E+10 |
| Minimum of Months | 0.149994E+09 | 52858399.85 | 70238955.06 | 0.197862E+09 | 9288705.11 |
| Maximum of Months | 0.218751E+09 | 0.100464E+09 | 0.137909E+09 | 0.416024E+09 | 0.257104E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.163106E+09 | 88094626.44 | 75011424.02 | 0.214994E+09 | 0.234689E+09 |
| February | 0.166715E+09 | 84264227.65 | 82450954.55 | 0.225275E+09 | 0.184906E+09 |
| March | 0.182253E+09 | 80642087.83 | 0.101611E+09 | 0.256483E+09 | 0.175570E+09 |
| April | 0.218751E+09 | 0.100464E+09 | 0.118287E+09 | 0.351144E+09 | 0.105281E+09 |
| May | 0.188304E+09 | 61283070.74 | 0.127021E+09 | 0.379060E+09 | 22139963.93 |
| June | 0.202615E+09 | 71213815.09 | 0.131401E+09 | 0.415642E+09 | 17272959.11 |
| July | 0.190768E+09 | 52858399.85 | 0.137909E+09 | 0.399229E+09 | 9320620.92 |
| August | 0.192879E+09 | 58813639.82 | 0.134066E+09 | 0.399593E+09 | 16424746.04 |
| September | 0.172085E+09 | 59083595.57 | 0.113002E+09 | 0.336677E+09 | 26146757.35 |
| October | 0.181583E+09 | 78285677.91 | 0.103297E+09 | 0.337356E+09 | 61515460.17 |
| November | 0.150867E+09 | 75789925.26 | 75076667.81 | 0.224689E+09 | 0.152665E+09 |
| December | 0.149994E+09 | 79754632.26 | 70238955.06 | 0.207555E+09 | 0.203201E+09 |
| Annual Sum or Average | 0.215992E+10 | 0.890548E+09 | 0.126937E+10 | 0.374770E+10 | 0.120913E+10 |
| Minimum of Months | 0.149994E+09 | 52858399.85 | 70238955.06 | 0.207555E+09 | 9320620.92 |
| Maximum of Months | 0.218751E+09 | 0.100464E+09 | 0.137909E+09 | 0.415642E+09 | 0.234689E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 64915977.03 | 0.378913E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 77568926.48 | 0.296311E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.127240E+09 | 0.277518E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.197088E+09 | 0.162643E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.360775E+09 | 32165113.07 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.411133E+09 | 24946752.72 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.416269E+09 | 13904598.16 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.374010E+09 | 24162307.28 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.285844E+09 | 39776664.66 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.234850E+09 | 94996946.99 |
| November | 90416797.23 | 0.00 | 90416797.23 | 95172259.31 | 0.241667E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 68853320.29 | 0.327134E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.271372E+10 | 0.191414E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 64915977.03 | 13904598.16 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.416269E+09 | 0.378913E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.748041E+09 | 0.353971E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.634523E+09 | 0.275830E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.450638E+09 | 0.269344E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.373748E+09 | 0.164738E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.376612E+09 | 33173849.81 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.372020E+09 | 25933642.87 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.406859E+09 | 13558948.44 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.467635E+09 | 25171858.16 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.505374E+09 | 40625549.40 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.714981E+09 | 93871601.03 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.758606E+09 | 0.223216E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.771310E+09 | 0.309511E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.658035E+10 | 0.182895E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.372020E+09 | 13558948.44 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.771310E+09 | 0.353971E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.154199E+09 | 78839041.99 | 75359594.22 | 0.176052E+09 | 0.248199E+09 |
| February | 0.154100E+09 | 74108536.14 | 79991098.96 | 0.187175E+09 | 0.188390E+09 |
| March | 0.201192E+09 | 96886895.73 | 0.104305E+09 | 0.272465E+09 | 0.172570E+09 |
| April | 0.214172E+09 | 97019692.19 | 0.117153E+09 | 0.335795E+09 | 0.102154E+09 |
| May | 0.227657E+09 | 98785597.66 | 0.128871E+09 | 0.443966E+09 | 20626214.45 |
| June | 0.223323E+09 | 88598292.67 | 0.134725E+09 | 0.451572E+09 | 15882291.70 |
| July | 0.222652E+09 | 81593955.70 | 0.141058E+09 | 0.455768E+09 | 8537484.55 |
| August | 0.205074E+09 | 70448943.86 | 0.134625E+09 | 0.416420E+09 | 15570317.33 |
| September | 0.175533E+09 | 60235005.99 | 0.115298E+09 | 0.338275E+09 | 25804071.17 |
| October | 0.179884E+09 | 76119207.32 | 0.103765E+09 | 0.323133E+09 | 60827834.80 |
| November | 0.153779E+09 | 78414852.08 | 75364185.52 | 0.210140E+09 | 0.151785E+09 |
| December | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.148872E+09 | 0.216009E+09 |
| Annual Sum or Average | 0.223677E+10 | 0.957839E+09 | 0.127893E+10 | 0.375963E+10 | 0.122636E+10 |
| Minimum of Months | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.148872E+09 | 8537484.55 |
| Maximum of Months | 0.227657E+09 | 98785597.66 | 0.141058E+09 | 0.455768E+09 | 0.248199E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.154199E+09 | 78839041.99 | 75359594.22 | 0.187983E+09 | 0.223356E+09 |
| February | 0.154100E+09 | 74108536.14 | 79991098.96 | 0.195521E+09 | 0.175267E+09 |
| March | 0.201192E+09 | 96886895.73 | 0.104305E+09 | 0.277736E+09 | 0.166519E+09 |
| April | 0.214172E+09 | 97019692.19 | 0.117153E+09 | 0.337608E+09 | 0.100993E+09 |
| May | 0.227657E+09 | 98785597.66 | 0.128871E+09 | 0.444146E+09 | 20606834.97 |
| June | 0.223323E+09 | 88598292.67 | 0.134725E+09 | 0.451188E+09 | 16015873.02 |
| July | 0.222652E+09 | 81593955.70 | 0.141058E+09 | 0.455615E+09 | 8569258.72 |
| August | 0.205074E+09 | 70448943.86 | 0.134625E+09 | 0.417383E+09 | 15384556.24 |
| September | 0.175533E+09 | 60235005.99 | 0.115298E+09 | 0.340304E+09 | 25001638.06 |
| October | 0.179884E+09 | 76119207.32 | 0.103765E+09 | 0.327678E+09 | 58240774.18 |
| November | 0.153779E+09 | 78414852.08 | 75364185.52 | 0.216822E+09 | 0.143932E+09 |
| December | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.158089E+09 | 0.197915E+09 |
| Annual Sum or Average | 0.223677E+10 | 0.957839E+09 | 0.127893E+10 | 0.381007E+10 | 0.115180E+10 |
| Minimum of Months | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.158089E+09 | 8569258.72 |
| Maximum of Months | 0.227657E+09 | 98785597.66 | 0.141058E+09 | 0.455615E+09 | 0.223356E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 63700752.13 | 0.377258E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 76388606.90 | 0.295176E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.125182E+09 | 0.276998E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.195859E+09 | 0.161830E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.359487E+09 | 31902543.35 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.410188E+09 | 24629714.03 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.415156E+09 | 13813844.33 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.373409E+09 | 23814225.99 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.285407E+09 | 39344830.57 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.234246E+09 | 94185443.46 |
| November | 90416797.23 | 0.00 | 90416797.23 | 93832468.31 | 0.241370E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 68454048.68 | 0.324602E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.270131E+10 | 0.190492E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 63700752.13 | 13813844.33 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.415156E+09 | 0.377258E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 63546339.50 | 0.388948E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 76727776.43 | 0.303668E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.126488E+09 | 0.284353E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.199088E+09 | 0.162603E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.365347E+09 | 30595970.81 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.416429E+09 | 23421822.88 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.421970E+09 | 12916027.73 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.379264E+09 | 22725760.43 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.289772E+09 | 38239601.66 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.237870E+09 | 94607623.53 |
| November | 90416797.23 | 0.00 | 90416797.23 | 94589019.10 | 0.247134E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 67718751.34 | 0.338434E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.273881E+10 | 0.194765E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 63546339.50 | 12916027.73 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.421970E+09 | 0.388948E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 63502286.18 | 0.388869E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 76668644.13 | 0.303659E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.126374E+09 | 0.284406E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.199039E+09 | 0.162582E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.365301E+09 | 30592761.05 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.416395E+09 | 23414277.94 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.421927E+09 | 12916158.33 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.379242E+09 | 22715172.51 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.289757E+09 | 38225712.83 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.237848E+09 | 94577818.20 |
| November | 90416797.23 | 0.00 | 90416797.23 | 94525347.75 | 0.247162E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 67730543.81 | 0.338182E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.273831E+10 | 0.194730E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 63502286.18 | 12916158.33 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.421927E+09 | 0.388869E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.743434E+09 | 0.369204E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.632478E+09 | 0.284630E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.451065E+09 | 0.277214E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.376835E+09 | 0.165395E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.382461E+09 | 31814139.01 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.378235E+09 | 24655634.66 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.413811E+09 | 12642345.20 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.473387E+09 | 24087419.55 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.509504E+09 | 39592153.03 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.718256E+09 | 94007711.90 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.759105E+09 | 0.226576E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.768070E+09 | 0.321367E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.660664E+10 | 0.187119E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.376835E+09 | 12642345.20 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.768070E+09 | 0.369204E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.743351E+09 | 0.369194E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.632423E+09 | 0.284590E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.450968E+09 | 0.277227E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.376795E+09 | 0.165367E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.382415E+09 | 31811023.25 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.378200E+09 | 24647304.62 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.413768E+09 | 12642360.68 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.473365E+09 | 24076534.89 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.509489E+09 | 39578193.40 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.718240E+09 | 93982006.70 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.759073E+09 | 0.226554E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.768067E+09 | 0.321272E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.660615E+10 | 0.187094E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.376795E+09 | 12642360.68 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.768067E+09 | 0.369194E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.753888E+09 | 0.323061E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.638163E+09 | 0.252457E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.453854E+09 | 0.244565E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.369729E+09 | 0.153987E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.365222E+09 | 33143875.58 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.359492E+09 | 26241625.53 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.393709E+09 | 13504854.84 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.454167E+09 | 25210564.53 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.494224E+09 | 40365737.95 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.705914E+09 | 88288213.31 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.761203E+09 | 0.202902E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.774626E+09 | 0.280587E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.652419E+10 | 0.168431E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.359492E+09 | 13504854.84 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.774626E+09 | 0.323061E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.163106E+09 | 88094626.44 | 75011424.02 | 0.199615E+09 | 0.231719E+09 |
| February | 0.166715E+09 | 84264227.65 | 82450954.55 | 0.214428E+09 | 0.177810E+09 |
| March | 0.182253E+09 | 80642087.83 | 0.101611E+09 | 0.249879E+09 | 0.162855E+09 |
| April | 0.218751E+09 | 0.100464E+09 | 0.118287E+09 | 0.344838E+09 | 98097359.65 |
| May | 0.188304E+09 | 61283070.74 | 0.127021E+09 | 0.370287E+09 | 21891942.69 |
| June | 0.202615E+09 | 71213815.09 | 0.131401E+09 | 0.406535E+09 | 16964799.92 |
| July | 0.190768E+09 | 52858399.85 | 0.137909E+09 | 0.389467E+09 | 9126282.48 |
| August | 0.192879E+09 | 58813639.82 | 0.134066E+09 | 0.389107E+09 | 16326732.10 |
| September | 0.172085E+09 | 59083595.57 | 0.113002E+09 | 0.326986E+09 | 26363810.29 |
| October | 0.181583E+09 | 78285677.91 | 0.103297E+09 | 0.326383E+09 | 59276926.10 |
| November | 0.150867E+09 | 75789925.26 | 75076667.81 | 0.215544E+09 | 0.143105E+09 |
| December | 0.149994E+09 | 79754632.26 | 70238955.06 | 0.196035E+09 | 0.196043E+09 |
| Annual Sum or Average | 0.215992E+10 | 0.890548E+09 | 0.126937E+10 | 0.362910E+10 | 0.115958E+10 |
| Minimum of Months | 0.149994E+09 | 52858399.85 | 70238955.06 | 0.196035E+09 | 9126282.48 |
| Maximum of Months | 0.218751E+09 | 0.100464E+09 | 0.137909E+09 | 0.406535E+09 | 0.231719E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.163106E+09 | 88094626.44 | 75011424.02 | 0.215091E+09 | 0.218804E+09 |
| February | 0.166715E+09 | 84264227.65 | 82450954.55 | 0.226020E+09 | 0.169395E+09 |
| March | 0.182253E+09 | 80642087.83 | 0.101611E+09 | 0.256994E+09 | 0.158477E+09 |
| April | 0.218751E+09 | 0.100464E+09 | 0.118287E+09 | 0.347922E+09 | 96736871.96 |
| May | 0.188304E+09 | 61283070.74 | 0.127021E+09 | 0.370501E+09 | 21921330.42 |
| June | 0.202615E+09 | 71213815.09 | 0.131401E+09 | 0.406027E+09 | 17107134.20 |
| July | 0.190768E+09 | 52858399.85 | 0.137909E+09 | 0.389238E+09 | 9160149.30 |
| August | 0.192879E+09 | 58813639.82 | 0.134066E+09 | 0.390422E+09 | 16213109.09 |
| September | 0.172085E+09 | 59083595.57 | 0.113002E+09 | 0.329768E+09 | 25738763.05 |
| October | 0.181583E+09 | 78285677.91 | 0.103297E+09 | 0.332945E+09 | 56686394.23 |
| November | 0.150867E+09 | 75789925.26 | 75076667.81 | 0.227162E+09 | 0.134293E+09 |
| December | 0.149994E+09 | 79754632.26 | 70238955.06 | 0.208838E+09 | 0.184379E+09 |
| Annual Sum or Average | 0.215992E+10 | 0.890548E+09 | 0.126937E+10 | 0.370093E+10 | 0.110891E+10 |
| Minimum of Months | 0.149994E+09 | 52858399.85 | 70238955.06 | 0.208838E+09 | 9160149.30 |
| Maximum of Months | 0.218751E+09 | 0.100464E+09 | 0.137909E+09 | 0.406027E+09 | 0.218804E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 65532138.91 | 0.354603E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 79399208.17 | 0.272802E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.128955E+09 | 0.251590E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.193895E+09 | 0.150249E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.348379E+09 | 32027856.66 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.397263E+09 | 24828136.07 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.402055E+09 | 13759742.83 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.360830E+09 | 23895801.34 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.275923E+09 | 39306245.33 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.228694E+09 | 87586980.54 |
| November | 90416797.23 | 0.00 | 90416797.23 | 99005886.93 | 0.213099E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 70958770.70 | 0.298070E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.265089E+10 | 0.176182E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 65532138.91 | 13759742.83 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.402055E+09 | 0.354603E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.750434E+09 | 0.320417E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.635380E+09 | 0.249985E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.449679E+09 | 0.242579E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.366999E+09 | 0.152060E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.363299E+09 | 32574220.68 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.358026E+09 | 25621815.97 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.392131E+09 | 13242311.82 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.453274E+09 | 24634939.29 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.493485E+09 | 39628248.23 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.704803E+09 | 86968555.36 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.758353E+09 | 0.201150E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.772927E+09 | 0.278087E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.649879E+10 | 0.166695E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.358026E+09 | 13242311.82 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.772927E+09 | 0.320417E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.154199E+09 | 78839041.99 | 75359594.22 | 0.178917E+09 | 0.226824E+09 |
| February | 0.154100E+09 | 74108536.14 | 79991098.96 | 0.189098E+09 | 0.172125E+09 |
| March | 0.201192E+09 | 96886895.73 | 0.104305E+09 | 0.273715E+09 | 0.156416E+09 |
| April | 0.214172E+09 | 97019692.19 | 0.117153E+09 | 0.332804E+09 | 95219151.09 |
| May | 0.227657E+09 | 98785597.66 | 0.128871E+09 | 0.434504E+09 | 20253526.55 |
| June | 0.223323E+09 | 88598292.67 | 0.134725E+09 | 0.441815E+09 | 15681655.68 |
| July | 0.222652E+09 | 81593955.70 | 0.141058E+09 | 0.445709E+09 | 8319200.94 |
| August | 0.205074E+09 | 70448943.86 | 0.134625E+09 | 0.406637E+09 | 15205473.29 |
| September | 0.175533E+09 | 60235005.99 | 0.115298E+09 | 0.330269E+09 | 25145993.00 |
| October | 0.179884E+09 | 76119207.32 | 0.103765E+09 | 0.316602E+09 | 56474444.21 |
| November | 0.153779E+09 | 78414852.08 | 75364185.52 | 0.211069E+09 | 0.137875E+09 |
| December | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.150534E+09 | 0.195335E+09 |
| Annual Sum or Average | 0.223677E+10 | 0.957839E+09 | 0.127893E+10 | 0.371167E+10 | 0.112488E+10 |
| Minimum of Months | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.150534E+09 | 8319200.94 |
| Maximum of Months | 0.227657E+09 | 98785597.66 | 0.141058E+09 | 0.445709E+09 | 0.226824E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.154199E+09 | 78839041.99 | 75359594.22 | 0.190027E+09 | 0.208855E+09 |
| February | 0.154100E+09 | 74108536.14 | 79991098.96 | 0.198417E+09 | 0.161189E+09 |
| March | 0.201192E+09 | 96886895.73 | 0.104305E+09 | 0.280104E+09 | 0.151131E+09 |
| April | 0.214172E+09 | 97019692.19 | 0.117153E+09 | 0.335644E+09 | 93670934.59 |
| May | 0.227657E+09 | 98785597.66 | 0.128871E+09 | 0.434725E+09 | 20273874.85 |
| June | 0.223323E+09 | 88598292.67 | 0.134725E+09 | 0.441311E+09 | 15817266.13 |
| July | 0.222652E+09 | 81593955.70 | 0.141058E+09 | 0.445487E+09 | 8355558.98 |
| August | 0.205074E+09 | 70448943.86 | 0.134625E+09 | 0.407955E+09 | 15088049.06 |
| September | 0.175533E+09 | 60235005.99 | 0.115298E+09 | 0.333076E+09 | 24494133.31 |
| October | 0.179884E+09 | 76119207.32 | 0.103765E+09 | 0.323412E+09 | 53511751.54 |
| November | 0.153779E+09 | 78414852.08 | 75364185.52 | 0.221720E+09 | 0.127336E+09 |
| December | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.161169E+09 | 0.180557E+09 |
| Annual Sum or Average | 0.223677E+10 | 0.957839E+09 | 0.127893E+10 | 0.377305E+10 | 0.106028E+10 |
| Minimum of Months | 0.125205E+09 | 56788907.17 | 68416348.72 | 0.161169E+09 | 8355558.98 |
| Maximum of Months | 0.227657E+09 | 98785597.66 | 0.141058E+09 | 0.445487E+09 | 0.208855E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 63214867.64 | 0.351493E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 76971923.51 | 0.269942E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.125009E+09 | 0.249379E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.190994E+09 | 0.148219E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.346547E+09 | 31446191.10 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.395896E+09 | 24252138.97 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.400549E+09 | 13519816.11 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.359970E+09 | 23335357.93 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.275189E+09 | 38580317.37 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.227565E+09 | 85878376.53 |
| November | 90416797.23 | 0.00 | 90416797.23 | 95943811.97 | 0.210501E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 69449339.91 | 0.294422E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.262730E+10 | 0.174097E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 63214867.64 | 13519816.11 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.400549E+09 | 0.351493E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 65564351.36 | 0.359279E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 79525714.22 | 0.277032E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.129790E+09 | 0.256430E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.196389E+09 | 0.152187E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.354315E+09 | 30950085.83 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.404046E+09 | 23726430.49 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.409092E+09 | 13099559.77 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.367579E+09 | 22902026.78 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.281126E+09 | 38338512.21 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.233004E+09 | 87970516.51 |
| November | 90416797.23 | 0.00 | 90416797.23 | 99374232.11 | 0.216916E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 71353726.55 | 0.302645E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.269116E+10 | 0.178148E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 65564351.36 | 13099559.77 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.409092E+09 | 0.359279E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 90678595.30 | 0.00 | 90678595.30 | 65404772.52 | 0.359060E+09 |
| February | 96626007.49 | 0.00 | 96626007.49 | 79356610.19 | 0.276823E+09 |
| March | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.129503E+09 | 0.256284E+09 |
| April | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.196203E+09 | 0.152058E+09 |
| May | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.354232E+09 | 30920579.22 |
| June | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.403984E+09 | 23696368.05 |
| July | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.409026E+09 | 13087072.10 |
| August | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.367537E+09 | 22871430.98 |
| September | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.281089E+09 | 38299844.90 |
| October | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.232940E+09 | 87836871.05 |
| November | 90416797.23 | 0.00 | 90416797.23 | 99157130.71 | 0.216729E+09 |
| December | 84296073.93 | 0.00 | 84296073.93 | 71242083.87 | 0.302324E+09 |
| Annual Sum or Average | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.268967E+10 | 0.177999E+10 |
| Minimum of Months | 84296073.93 | 0.00 | 84296073.93 | 65404772.52 | 13087072.10 |
| Maximum of Months | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.409026E+09 | 0.359060E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.750664E+09 | 0.332042E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.635996E+09 | 0.259164E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.453372E+09 | 0.250882E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.371957E+09 | 0.156072E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.371159E+09 | 32046654.50 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.366165E+09 | 25034373.70 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.400886E+09 | 12819146.27 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.460799E+09 | 24205564.67 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.499139E+09 | 39437606.27 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.709328E+09 | 89089062.38 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.759945E+09 | 0.208497E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.772590E+09 | 0.288333E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.655200E+10 | 0.171762E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.366165E+09 | 12819146.27 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.772590E+09 | 0.332042E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.750430E+09 | 0.331861E+09 |
| February | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.635822E+09 | 0.258986E+09 |
| March | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.453108E+09 | 0.250753E+09 |
| April | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.371802E+09 | 0.155952E+09 |
| May | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.371072E+09 | 32016207.44 |
| June | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.366097E+09 | 25002352.66 |
| July | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.400817E+09 | 12805676.30 |
| August | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.460757E+09 | 24174358.01 |
| September | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.499103E+09 | 39399356.83 |
| October | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.709271E+09 | 89008382.88 |
| November | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.759797E+09 | 0.208389E+09 |
| December | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.772484E+09 | 0.288140E+09 |
| Annual Sum or Average | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.655056E+10 | 0.171649E+10 |
| Minimum of Months | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.366097E+09 | 12805676.30 |
| Maximum of Months | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.772484E+09 | 0.331861E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 37000590.41 | 18917749.03 | 18082841.38 | 42842935.81 | 58346153.85 |
| February | 36976834.69 | 17782644.90 | 19194189.79 | 45005212.09 | 45273204.61 |
| March | 48276830.86 | 23248405.00 | 25028425.86 | 64100243.29 | 42813926.74 |
| April | 51391516.41 | 23280270.05 | 28111246.36 | 76704098.65 | 27833681.87 |
| May | 54627221.13 | 23704006.26 | 30923214.88 | 98030789.38 | 9061869.24 |
| June | 53587221.80 | 21259520.96 | 32327700.85 | 99869963.46 | 7678003.98 |
| July | 53426268.34 | 19578801.79 | 33847466.55 | 99742715.86 | 5278786.72 |
| August | 49208437.11 | 16904510.83 | 32303926.28 | 91157481.24 | 7450244.60 |
| September | 42119847.63 | 14453634.87 | 27666212.77 | 74333606.49 | 10438535.10 |
| October | 43163945.43 | 18265113.63 | 24898831.79 | 72194079.71 | 18576303.07 |
| November | 36899906.01 | 18815962.94 | 18083943.08 | 49827567.32 | 37687363.55 |
| December | 30043510.79 | 13626729.43 | 16416781.36 | 35797497.09 | 51454753.92 |
| Annual Sum or Average | 0.536722E+09 | 0.229837E+09 | 0.306885E+09 | 0.849606E+09 | 0.321893E+09 |
| Minimum of Months | 30043510.79 | 13626729.43 | 16416781.36 | 35797497.09 | 5278786.72 |
| Maximum of Months | 54627221.13 | 23704006.26 | 33847466.55 | 99869963.46 | 58346153.85 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.110197E+09 | 56341764.55 | 53855201.78 | 0.127847E+09 | 0.176430E+09 |
| February | 0.110126E+09 | 52961141.95 | 57165073.93 | 0.135710E+09 | 0.133947E+09 |
| March | 0.143780E+09 | 69239535.76 | 74540880.88 | 0.193339E+09 | 0.127388E+09 |
| April | 0.153057E+09 | 69334437.82 | 83722287.52 | 0.229975E+09 | 83186095.08 |
| May | 0.162693E+09 | 70596429.69 | 92097029.55 | 0.289785E+09 | 30264632.99 |
| June | 0.159596E+09 | 63316144.12 | 96279938.30 | 0.293449E+09 | 26796508.67 |
| July | 0.159117E+09 | 58310544.18 | 0.100806E+09 | 0.291237E+09 | 20810328.49 |
| August | 0.146555E+09 | 50345840.18 | 96209131.71 | 0.265229E+09 | 28313128.35 |
| September | 0.125443E+09 | 43046521.61 | 82396866.72 | 0.216643E+09 | 37767378.88 |
| October | 0.128553E+09 | 54398053.92 | 74154917.49 | 0.210789E+09 | 63188915.37 |
| November | 0.109897E+09 | 56038620.23 | 53858482.92 | 0.144142E+09 | 0.120846E+09 |
| December | 89477051.85 | 40583791.43 | 48893260.42 | 0.104291E+09 | 0.161437E+09 |
| Annual Sum or Average | 0.159849E+10 | 0.684513E+09 | 0.913979E+09 | 0.250244E+10 | 0.101037E+10 |
| Minimum of Months | 89477051.85 | 40583791.43 | 48893260.42 | 0.104291E+09 | 20810328.49 |
| Maximum of Months | 0.162693E+09 | 70596429.69 | 0.100806E+09 | 0.293449E+09 | 0.176430E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 37000590.41 | 18917749.03 | 18082841.38 | 40270961.46 | 65137084.14 |
| February | 36976834.69 | 17782644.90 | 19194189.79 | 42639164.32 | 50464594.48 |
| March | 48276830.86 | 23248405.00 | 25028425.86 | 61760290.36 | 47876509.84 |
| April | 51391516.41 | 23280270.05 | 28111246.36 | 75740706.46 | 29657414.60 |
| May | 54627221.13 | 23704006.26 | 30923214.88 | 99756410.80 | 8819721.68 |
| June | 53587221.80 | 21259520.96 | 32327700.85 | 0.101752E+09 | 7380667.88 |
| July | 53426268.34 | 19578801.79 | 33847466.55 | 0.101842E+09 | 5002224.09 |
| August | 49208437.11 | 16904510.83 | 32303926.28 | 93086392.14 | 7218295.84 |
| September | 42119847.63 | 14453634.87 | 27666212.77 | 75652279.46 | 10442574.86 |
| October | 43163945.43 | 18265113.63 | 24898831.79 | 72552654.73 | 19559990.76 |
| November | 36899906.01 | 18815962.94 | 18083943.08 | 47376197.92 | 42037990.85 |
| December | 30043510.79 | 13626729.43 | 16416781.36 | 33540028.42 | 58227960.89 |
| Annual Sum or Average | 0.536722E+09 | 0.229837E+09 | 0.306885E+09 | 0.845969E+09 | 0.351825E+09 |
| Minimum of Months | 30043510.79 | 13626729.43 | 16416781.36 | 33540028.42 | 5002224.09 |
| Maximum of Months | 54627221.13 | 23704006.26 | 33847466.55 | 0.101842E+09 | 65137084.14 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 351.55 | 221.28 | 254.66 | 170.52 | 84.14 | 0.00 | 0.00 |
| February | 353.59 | 185.03 | 247.66 | 150.97 | 96.69 | 0.00 | 0.00 |
| March | 267.18 | 158.62 | 179.89 | 79.78 | 100.10 | 0.00 | 0.00 |
| April | 283.24 | 99.01 | 170.26 | 60.31 | 109.95 | 0.00 | 0.00 |
| May | 284.74 | 19.88 | 134.69 | 25.80 | 108.89 | 0.00 | 0.00 |
| June | 305.61 | 16.49 | 141.63 | 28.13 | 113.50 | 0.00 | 0.00 |
| July | 300.59 | 9.16 | 137.62 | 20.98 | 116.64 | 0.00 | 0.00 |
| August | 321.13 | 17.81 | 149.43 | 30.66 | 118.77 | 0.00 | 0.00 |
| September | 322.40 | 29.14 | 161.33 | 48.74 | 112.59 | 0.00 | 0.00 |
| October | 390.06 | 61.89 | 210.52 | 102.32 | 108.19 | 0.00 | 0.00 |
| November | 373.94 | 146.90 | 243.89 | 157.31 | 86.58 | 0.00 | 0.00 |
| December | 358.73 | 196.35 | 246.91 | 166.79 | 80.12 | 0.00 | 0.00 |
| Annual Sum or Average | 325.89 | 96.33 | 189.51 | 86.48 | 103.04 | 0.00 | 0.00 |
| Minimum of Months | 267.18 | 9.16 | 134.69 | 20.98 | 80.12 | 0.00 | 0.00 |
| Maximum of Months | 390.06 | 221.28 | 254.66 | 170.52 | 118.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 100.05 | 220.47 | 94.75 | 32.89 | 61.86 | 0.00 | 0.00 |
| February | 126.11 | 184.61 | 108.85 | 34.83 | 74.02 | 0.00 | 0.00 |
| March | 147.60 | 156.68 | 114.39 | 30.11 | 84.28 | 0.00 | 0.00 |
| April | 215.74 | 96.59 | 139.23 | 39.08 | 100.14 | 0.00 | 0.00 |
| May | 278.19 | 19.29 | 132.36 | 25.22 | 107.14 | 0.00 | 0.00 |
| June | 319.99 | 16.05 | 148.52 | 32.26 | 116.25 | 0.00 | 0.00 |
| July | 303.58 | 9.29 | 139.54 | 22.28 | 117.26 | 0.00 | 0.00 |
| August | 286.05 | 17.20 | 133.45 | 22.59 | 110.86 | 0.00 | 0.00 |
| September | 237.88 | 28.10 | 119.29 | 22.80 | 96.49 | 0.00 | 0.00 |
| October | 211.29 | 60.91 | 113.74 | 29.23 | 84.52 | 0.00 | 0.00 |
| November | 120.30 | 151.96 | 93.09 | 29.24 | 63.85 | 0.00 | 0.00 |
| December | 99.00 | 195.58 | 87.47 | 29.78 | 57.70 | 0.00 | 0.00 |
| Annual Sum or Average | 204.24 | 95.92 | 118.74 | 29.13 | 89.61 | 0.00 | 0.00 |
| Minimum of Months | 99.00 | 9.29 | 87.47 | 22.28 | 57.70 | 0.00 | 0.00 |
| Maximum of Months | 319.99 | 220.47 | 148.52 | 39.08 | 117.26 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 335.30 | 236.50 | 251.33 | 167.07 | 84.27 | 0.00 | 0.00 |
| February | 336.10 | 197.81 | 242.44 | 146.77 | 95.67 | 0.00 | 0.00 |
| March | 265.00 | 172.32 | 186.96 | 85.85 | 101.11 | 0.00 | 0.00 |
| April | 261.52 | 119.57 | 168.50 | 58.98 | 109.52 | 0.00 | 0.00 |
| May | 277.24 | 51.89 | 149.38 | 39.80 | 109.58 | 0.00 | 0.00 |
| June | 286.24 | 49.38 | 149.61 | 34.84 | 114.78 | 0.00 | 0.00 |
| July | 279.60 | 43.03 | 149.53 | 31.71 | 117.82 | 0.00 | 0.00 |
| August | 293.18 | 54.65 | 153.98 | 35.00 | 118.97 | 0.00 | 0.00 |
| September | 292.32 | 70.87 | 162.66 | 49.19 | 113.47 | 0.00 | 0.00 |
| October | 361.37 | 103.37 | 209.88 | 101.51 | 108.37 | 0.00 | 0.00 |
| November | 358.82 | 175.36 | 245.01 | 158.32 | 86.69 | 0.00 | 0.00 |
| December | 331.52 | 219.26 | 237.66 | 158.22 | 79.44 | 0.00 | 0.00 |
| Annual Sum or Average | 306.35 | 124.13 | 191.95 | 88.61 | 103.34 | 0.00 | 0.00 |
| Minimum of Months | 261.52 | 43.03 | 149.38 | 31.71 | 79.44 | 0.00 | 0.00 |
| Maximum of Months | 361.37 | 236.50 | 251.33 | 167.07 | 118.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 85.58 | 211.91 | 91.43 | 29.44 | 61.99 | 0.00 | 0.00 |
| February | 109.45 | 176.29 | 103.64 | 30.63 | 73.01 | 0.00 | 0.00 |
| March | 151.50 | 149.63 | 121.46 | 36.18 | 85.29 | 0.00 | 0.00 |
| April | 208.66 | 93.37 | 137.46 | 37.75 | 99.70 | 0.00 | 0.00 |
| May | 302.38 | 18.95 | 147.05 | 39.22 | 107.83 | 0.00 | 0.00 |
| June | 333.50 | 15.64 | 156.51 | 38.97 | 117.54 | 0.00 | 0.00 |
| July | 324.26 | 9.09 | 151.45 | 33.01 | 118.43 | 0.00 | 0.00 |
| August | 292.42 | 16.65 | 138.00 | 26.94 | 111.07 | 0.00 | 0.00 |
| September | 238.95 | 27.35 | 120.62 | 23.25 | 97.37 | 0.00 | 0.00 |
| October | 206.65 | 58.55 | 113.11 | 28.42 | 84.69 | 0.00 | 0.00 |
| November | 112.08 | 143.63 | 94.21 | 30.25 | 63.96 | 0.00 | 0.00 |
| December | 78.38 | 190.73 | 78.22 | 21.20 | 57.02 | 0.00 | 0.00 |
| Annual Sum or Average | 204.21 | 92.21 | 121.17 | 31.26 | 89.91 | 0.00 | 0.00 |
| Minimum of Months | 78.38 | 9.09 | 78.22 | 21.20 | 57.02 | 0.00 | 0.00 |
| Maximum of Months | 333.50 | 211.91 | 156.51 | 39.22 | 118.43 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 24.51 | 143.13 | 33.86 | 0.00 | 33.86 | 0.00 | 0.00 |
| February | 34.12 | 119.01 | 39.94 | 0.00 | 39.94 | 0.00 | 0.00 |
| March | 50.13 | 100.30 | 46.35 | 0.00 | 46.34 | 0.00 | 0.00 |
| April | 78.74 | 60.21 | 54.83 | 0.32 | 54.51 | 0.00 | 0.00 |
| May | 137.00 | 11.29 | 62.05 | 2.34 | 59.72 | 0.00 | 0.00 |
| June | 160.76 | 9.20 | 70.35 | 4.79 | 65.56 | 0.00 | 0.00 |
| July | 156.74 | 5.24 | 68.32 | 2.55 | 65.77 | 0.00 | 0.00 |
| August | 139.99 | 9.52 | 61.44 | 0.63 | 60.81 | 0.00 | 0.00 |
| September | 110.51 | 16.10 | 52.90 | 0.01 | 52.89 | 0.00 | 0.00 |
| October | 87.74 | 36.57 | 45.95 | 0.00 | 45.95 | 0.00 | 0.00 |
| November | 36.28 | 95.77 | 34.88 | 0.00 | 34.88 | 0.00 | 0.00 |
| December | 25.25 | 126.30 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Annual Sum or Average | 87.14 | 60.75 | 50.25 | 0.89 | 49.36 | 0.00 | 0.00 |
| Minimum of Months | 24.51 | 5.24 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Maximum of Months | 160.76 | 143.13 | 70.35 | 4.79 | 65.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 24.50 | 143.12 | 33.86 | 0.00 | 33.86 | 0.00 | 0.00 |
| February | 34.10 | 119.00 | 39.94 | 0.00 | 39.94 | 0.00 | 0.00 |
| March | 50.10 | 100.31 | 46.35 | 0.00 | 46.34 | 0.00 | 0.00 |
| April | 78.72 | 60.21 | 54.83 | 0.32 | 54.51 | 0.00 | 0.00 |
| May | 136.97 | 11.30 | 62.05 | 2.34 | 59.72 | 0.00 | 0.00 |
| June | 160.74 | 9.20 | 70.35 | 4.79 | 65.56 | 0.00 | 0.00 |
| July | 156.72 | 5.24 | 68.32 | 2.55 | 65.77 | 0.00 | 0.00 |
| August | 139.98 | 9.52 | 61.44 | 0.63 | 60.81 | 0.00 | 0.00 |
| September | 110.50 | 16.09 | 52.90 | 0.01 | 52.89 | 0.00 | 0.00 |
| October | 87.73 | 36.56 | 45.95 | 0.00 | 45.95 | 0.00 | 0.00 |
| November | 36.26 | 95.78 | 34.88 | 0.00 | 34.88 | 0.00 | 0.00 |
| December | 25.26 | 126.21 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Annual Sum or Average | 87.13 | 60.74 | 50.25 | 0.89 | 49.36 | 0.00 | 0.00 |
| Minimum of Months | 24.50 | 5.24 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Maximum of Months | 160.74 | 143.12 | 70.35 | 4.79 | 65.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 279.70 | 136.92 | 193.76 | 137.63 | 56.13 | 0.00 | 0.00 |
| February | 264.80 | 114.74 | 178.74 | 116.14 | 62.61 | 0.00 | 0.00 |
| March | 171.65 | 99.68 | 111.84 | 49.67 | 62.17 | 0.00 | 0.00 |
| April | 147.42 | 61.91 | 85.87 | 21.55 | 64.32 | 0.00 | 0.00 |
| May | 143.39 | 11.76 | 64.39 | 2.92 | 61.47 | 0.00 | 0.00 |
| June | 146.01 | 9.62 | 63.46 | 0.66 | 62.80 | 0.00 | 0.00 |
| July | 153.61 | 5.16 | 66.40 | 1.25 | 65.15 | 0.00 | 0.00 |
| August | 175.34 | 10.07 | 77.41 | 8.70 | 68.71 | 0.00 | 0.00 |
| September | 195.69 | 16.82 | 94.94 | 25.95 | 68.99 | 0.00 | 0.00 |
| October | 267.96 | 36.60 | 142.72 | 73.10 | 69.63 | 0.00 | 0.00 |
| November | 293.67 | 88.34 | 185.68 | 128.07 | 57.62 | 0.00 | 0.00 |
| December | 287.86 | 120.86 | 190.91 | 137.01 | 53.89 | 0.00 | 0.00 |
| Annual Sum or Average | 210.31 | 59.08 | 121.02 | 58.24 | 62.78 | 0.00 | 0.00 |
| Minimum of Months | 143.39 | 5.16 | 63.46 | 0.66 | 53.89 | 0.00 | 0.00 |
| Maximum of Months | 293.67 | 136.92 | 193.76 | 137.63 | 69.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 279.28 | 137.59 | 193.76 | 137.63 | 56.13 | 0.00 | 0.00 |
| February | 264.43 | 115.25 | 178.74 | 116.14 | 62.61 | 0.00 | 0.00 |
| March | 171.18 | 100.44 | 111.84 | 49.67 | 62.17 | 0.00 | 0.00 |
| April | 146.92 | 62.53 | 85.87 | 21.55 | 64.32 | 0.00 | 0.00 |
| May | 142.38 | 12.47 | 64.39 | 2.92 | 61.47 | 0.00 | 0.00 |
| June | 144.94 | 10.29 | 63.46 | 0.66 | 62.80 | 0.00 | 0.00 |
| July | 152.23 | 5.70 | 66.40 | 1.25 | 65.15 | 0.00 | 0.00 |
| August | 174.21 | 10.76 | 77.41 | 8.70 | 68.71 | 0.00 | 0.00 |
| September | 194.78 | 17.72 | 94.94 | 25.95 | 68.99 | 0.00 | 0.00 |
| October | 267.19 | 37.48 | 142.72 | 73.10 | 69.63 | 0.00 | 0.00 |
| November | 293.22 | 89.00 | 185.68 | 128.07 | 57.62 | 0.00 | 0.00 |
| December | 287.44 | 121.61 | 190.91 | 137.01 | 53.89 | 0.00 | 0.00 |
| Annual Sum or Average | 209.56 | 59.78 | 121.02 | 58.24 | 62.78 | 0.00 | 0.00 |
| Minimum of Months | 142.38 | 5.70 | 63.46 | 0.66 | 53.89 | 0.00 | 0.00 |
| Maximum of Months | 293.22 | 137.59 | 193.76 | 137.63 | 69.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 348.84 | 222.13 | 254.66 | 170.52 | 84.14 | 0.00 | 0.00 |
| February | 347.43 | 191.26 | 247.66 | 150.97 | 96.69 | 0.00 | 0.00 |
| March | 260.66 | 166.44 | 179.89 | 79.78 | 100.10 | 0.00 | 0.00 |
| April | 278.13 | 103.74 | 170.26 | 60.31 | 109.95 | 0.00 | 0.00 |
| May | 282.53 | 20.72 | 134.69 | 25.80 | 108.89 | 0.00 | 0.00 |
| June | 304.38 | 16.71 | 141.63 | 28.13 | 113.50 | 0.00 | 0.00 |
| July | 301.40 | 8.52 | 137.62 | 20.98 | 116.64 | 0.00 | 0.00 |
| August | 323.63 | 15.70 | 149.43 | 30.66 | 118.77 | 0.00 | 0.00 |
| September | 324.19 | 26.17 | 161.33 | 48.74 | 112.59 | 0.00 | 0.00 |
| October | 391.05 | 58.81 | 210.52 | 102.32 | 108.19 | 0.00 | 0.00 |
| November | 373.40 | 144.63 | 243.89 | 157.31 | 86.58 | 0.00 | 0.00 |
| December | 357.74 | 193.93 | 246.91 | 166.79 | 80.12 | 0.00 | 0.00 |
| Annual Sum or Average | 324.31 | 96.89 | 189.51 | 86.48 | 103.04 | 0.00 | 0.00 |
| Minimum of Months | 260.66 | 8.52 | 134.69 | 20.98 | 80.12 | 0.00 | 0.00 |
| Maximum of Months | 391.05 | 222.13 | 254.66 | 170.52 | 118.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 98.49 | 223.07 | 94.75 | 32.89 | 61.86 | 0.00 | 0.00 |
| February | 120.58 | 194.31 | 108.85 | 34.83 | 74.02 | 0.00 | 0.00 |
| March | 141.08 | 166.98 | 114.39 | 30.11 | 84.28 | 0.00 | 0.00 |
| April | 210.50 | 102.36 | 139.23 | 39.08 | 100.14 | 0.00 | 0.00 |
| May | 276.02 | 20.07 | 132.36 | 25.22 | 107.14 | 0.00 | 0.00 |
| June | 318.82 | 16.14 | 148.52 | 32.26 | 116.25 | 0.00 | 0.00 |
| July | 304.42 | 8.62 | 139.54 | 22.28 | 117.26 | 0.00 | 0.00 |
| August | 288.79 | 15.12 | 133.45 | 22.59 | 110.86 | 0.00 | 0.00 |
| September | 240.11 | 25.37 | 119.29 | 22.80 | 96.49 | 0.00 | 0.00 |
| October | 213.23 | 58.03 | 113.74 | 29.23 | 84.52 | 0.00 | 0.00 |
| November | 120.98 | 149.71 | 93.09 | 29.24 | 63.85 | 0.00 | 0.00 |
| December | 99.21 | 194.02 | 87.47 | 29.78 | 57.70 | 0.00 | 0.00 |
| Annual Sum or Average | 203.14 | 97.29 | 118.74 | 29.13 | 89.61 | 0.00 | 0.00 |
| Minimum of Months | 98.49 | 8.62 | 87.47 | 22.28 | 57.70 | 0.00 | 0.00 |
| Maximum of Months | 318.82 | 223.07 | 148.52 | 39.08 | 117.26 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 339.99 | 219.80 | 251.33 | 167.07 | 84.27 | 0.00 | 0.00 |
| February | 335.93 | 188.17 | 242.44 | 146.77 | 95.67 | 0.00 | 0.00 |
| March | 266.51 | 161.52 | 186.96 | 85.85 | 101.11 | 0.00 | 0.00 |
| April | 270.76 | 99.99 | 168.50 | 58.98 | 109.52 | 0.00 | 0.00 |
| May | 305.99 | 19.71 | 149.38 | 39.80 | 109.58 | 0.00 | 0.00 |
| June | 317.45 | 15.84 | 149.61 | 34.84 | 114.78 | 0.00 | 0.00 |
| July | 321.99 | 8.17 | 149.53 | 31.71 | 117.82 | 0.00 | 0.00 |
| August | 329.87 | 15.01 | 153.98 | 35.00 | 118.97 | 0.00 | 0.00 |
| September | 325.29 | 25.43 | 162.66 | 49.19 | 113.47 | 0.00 | 0.00 |
| October | 387.05 | 57.22 | 209.88 | 101.51 | 108.37 | 0.00 | 0.00 |
| November | 371.78 | 142.71 | 245.01 | 158.32 | 86.69 | 0.00 | 0.00 |
| December | 340.45 | 193.10 | 237.66 | 158.22 | 79.44 | 0.00 | 0.00 |
| Annual Sum or Average | 326.06 | 95.06 | 191.95 | 88.61 | 103.34 | 0.00 | 0.00 |
| Minimum of Months | 266.51 | 8.17 | 149.38 | 31.71 | 79.44 | 0.00 | 0.00 |
| Maximum of Months | 387.05 | 219.80 | 251.33 | 167.07 | 118.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 83.89 | 214.16 | 91.43 | 29.44 | 61.99 | 0.00 | 0.00 |
| February | 103.77 | 185.83 | 103.64 | 30.63 | 73.01 | 0.00 | 0.00 |
| March | 144.31 | 159.47 | 121.46 | 36.18 | 85.29 | 0.00 | 0.00 |
| April | 203.18 | 98.77 | 137.46 | 37.75 | 99.70 | 0.00 | 0.00 |
| May | 300.03 | 19.59 | 147.05 | 39.22 | 107.83 | 0.00 | 0.00 |
| June | 332.29 | 15.65 | 156.51 | 38.97 | 117.54 | 0.00 | 0.00 |
| July | 325.09 | 8.34 | 151.45 | 33.01 | 118.43 | 0.00 | 0.00 |
| August | 295.17 | 14.56 | 138.00 | 26.94 | 111.07 | 0.00 | 0.00 |
| September | 241.19 | 24.62 | 120.62 | 23.25 | 97.37 | 0.00 | 0.00 |
| October | 208.54 | 55.66 | 113.11 | 28.42 | 84.69 | 0.00 | 0.00 |
| November | 112.72 | 141.52 | 94.21 | 30.25 | 63.96 | 0.00 | 0.00 |
| December | 78.58 | 189.09 | 78.22 | 21.20 | 57.02 | 0.00 | 0.00 |
| Annual Sum or Average | 202.99 | 93.44 | 121.17 | 31.26 | 89.91 | 0.00 | 0.00 |
| Minimum of Months | 78.58 | 8.34 | 78.22 | 21.20 | 57.02 | 0.00 | 0.00 |
| Maximum of Months | 332.29 | 214.16 | 156.51 | 39.22 | 118.43 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 23.73 | 145.22 | 33.86 | 0.00 | 33.86 | 0.00 | 0.00 |
| February | 31.72 | 125.52 | 39.94 | 0.00 | 39.94 | 0.00 | 0.00 |
| March | 47.23 | 106.17 | 46.35 | 0.00 | 46.34 | 0.00 | 0.00 |
| April | 76.81 | 62.73 | 54.83 | 0.32 | 54.51 | 0.00 | 0.00 |
| May | 136.41 | 11.42 | 62.05 | 2.34 | 59.72 | 0.00 | 0.00 |
| June | 160.66 | 9.04 | 70.35 | 4.79 | 65.56 | 0.00 | 0.00 |
| July | 157.55 | 4.82 | 68.32 | 2.55 | 65.77 | 0.00 | 0.00 |
| August | 141.60 | 8.48 | 61.44 | 0.63 | 60.81 | 0.00 | 0.00 |
| September | 111.79 | 14.75 | 52.90 | 0.01 | 52.89 | 0.00 | 0.00 |
| October | 88.81 | 35.32 | 45.95 | 0.00 | 45.95 | 0.00 | 0.00 |
| November | 36.49 | 95.35 | 34.88 | 0.00 | 34.88 | 0.00 | 0.00 |
| December | 25.28 | 126.36 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Annual Sum or Average | 86.85 | 61.76 | 50.25 | 0.89 | 49.36 | 0.00 | 0.00 |
| Minimum of Months | 23.73 | 4.82 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Maximum of Months | 160.66 | 145.22 | 70.35 | 4.79 | 65.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 23.71 | 145.19 | 33.86 | 0.00 | 33.86 | 0.00 | 0.00 |
| February | 31.69 | 125.52 | 39.94 | 0.00 | 39.94 | 0.00 | 0.00 |
| March | 47.18 | 106.19 | 46.35 | 0.00 | 46.34 | 0.00 | 0.00 |
| April | 76.79 | 62.72 | 54.83 | 0.32 | 54.51 | 0.00 | 0.00 |
| May | 136.39 | 11.42 | 62.05 | 2.34 | 59.72 | 0.00 | 0.00 |
| June | 160.65 | 9.03 | 70.35 | 4.79 | 65.56 | 0.00 | 0.00 |
| July | 157.53 | 4.82 | 68.32 | 2.55 | 65.77 | 0.00 | 0.00 |
| August | 141.59 | 8.48 | 61.44 | 0.63 | 60.81 | 0.00 | 0.00 |
| September | 111.79 | 14.75 | 52.90 | 0.01 | 52.89 | 0.00 | 0.00 |
| October | 88.80 | 35.31 | 45.95 | 0.00 | 45.95 | 0.00 | 0.00 |
| November | 36.47 | 95.36 | 34.88 | 0.00 | 34.88 | 0.00 | 0.00 |
| December | 25.29 | 126.26 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Annual Sum or Average | 86.83 | 61.75 | 50.25 | 0.89 | 49.36 | 0.00 | 0.00 |
| Minimum of Months | 23.71 | 4.82 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Maximum of Months | 160.65 | 145.19 | 70.35 | 4.79 | 65.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 277.57 | 137.84 | 193.76 | 137.63 | 56.13 | 0.00 | 0.00 |
| February | 261.44 | 117.65 | 178.74 | 116.14 | 62.61 | 0.00 | 0.00 |
| March | 168.41 | 103.50 | 111.84 | 49.67 | 62.17 | 0.00 | 0.00 |
| April | 145.38 | 63.81 | 85.87 | 21.55 | 64.32 | 0.00 | 0.00 |
| May | 142.79 | 11.88 | 64.39 | 2.92 | 61.47 | 0.00 | 0.00 |
| June | 145.92 | 9.51 | 63.46 | 0.66 | 62.80 | 0.00 | 0.00 |
| July | 154.50 | 4.72 | 66.40 | 1.25 | 65.15 | 0.00 | 0.00 |
| August | 176.74 | 8.99 | 77.41 | 8.70 | 68.71 | 0.00 | 0.00 |
| September | 196.57 | 15.27 | 94.94 | 25.95 | 68.99 | 0.00 | 0.00 |
| October | 268.17 | 35.10 | 142.72 | 73.10 | 69.63 | 0.00 | 0.00 |
| November | 292.86 | 87.41 | 185.68 | 128.07 | 57.62 | 0.00 | 0.00 |
| December | 286.76 | 119.98 | 190.91 | 137.01 | 53.89 | 0.00 | 0.00 |
| Annual Sum or Average | 209.50 | 59.33 | 121.02 | 58.24 | 62.78 | 0.00 | 0.00 |
| Minimum of Months | 142.79 | 4.72 | 63.46 | 0.66 | 53.89 | 0.00 | 0.00 |
| Maximum of Months | 292.86 | 137.84 | 193.76 | 137.63 | 69.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 277.54 | 137.84 | 193.76 | 137.63 | 56.13 | 0.00 | 0.00 |
| February | 261.42 | 117.64 | 178.74 | 116.14 | 62.61 | 0.00 | 0.00 |
| March | 168.37 | 103.50 | 111.84 | 49.67 | 62.17 | 0.00 | 0.00 |
| April | 145.37 | 63.80 | 85.87 | 21.55 | 64.32 | 0.00 | 0.00 |
| May | 142.78 | 11.88 | 64.39 | 2.92 | 61.47 | 0.00 | 0.00 |
| June | 145.91 | 9.51 | 63.46 | 0.66 | 62.80 | 0.00 | 0.00 |
| July | 154.48 | 4.72 | 66.40 | 1.25 | 65.15 | 0.00 | 0.00 |
| August | 176.73 | 8.99 | 77.41 | 8.70 | 68.71 | 0.00 | 0.00 |
| September | 196.56 | 15.27 | 94.94 | 25.95 | 68.99 | 0.00 | 0.00 |
| October | 268.16 | 35.09 | 142.72 | 73.10 | 69.63 | 0.00 | 0.00 |
| November | 292.85 | 87.41 | 185.68 | 128.07 | 57.62 | 0.00 | 0.00 |
| December | 286.76 | 119.95 | 190.91 | 137.01 | 53.89 | 0.00 | 0.00 |
| Annual Sum or Average | 209.48 | 59.33 | 121.02 | 58.24 | 62.78 | 0.00 | 0.00 |
| Minimum of Months | 142.78 | 4.72 | 63.46 | 0.66 | 53.89 | 0.00 | 0.00 |
| Maximum of Months | 292.85 | 137.84 | 193.76 | 137.63 | 69.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 350.57 | 201.70 | 254.66 | 170.52 | 84.14 | 0.00 | 0.00 |
| February | 348.38 | 173.81 | 247.66 | 150.97 | 96.69 | 0.00 | 0.00 |
| March | 260.74 | 150.11 | 179.89 | 79.78 | 100.10 | 0.00 | 0.00 |
| April | 274.34 | 95.91 | 170.26 | 60.31 | 109.95 | 0.00 | 0.00 |
| May | 274.57 | 20.51 | 134.69 | 25.80 | 108.89 | 0.00 | 0.00 |
| June | 295.47 | 16.60 | 141.63 | 28.13 | 113.50 | 0.00 | 0.00 |
| July | 292.33 | 8.37 | 137.62 | 20.98 | 116.64 | 0.00 | 0.00 |
| August | 314.80 | 15.46 | 149.43 | 30.66 | 118.77 | 0.00 | 0.00 |
| September | 316.74 | 25.66 | 161.33 | 48.74 | 112.59 | 0.00 | 0.00 |
| October | 385.07 | 54.75 | 210.52 | 102.32 | 108.19 | 0.00 | 0.00 |
| November | 373.89 | 130.55 | 243.89 | 157.31 | 86.58 | 0.00 | 0.00 |
| December | 359.05 | 174.60 | 246.91 | 166.79 | 80.12 | 0.00 | 0.00 |
| Annual Sum or Average | 320.32 | 88.55 | 189.51 | 86.48 | 103.04 | 0.00 | 0.00 |
| Minimum of Months | 260.74 | 8.37 | 134.69 | 20.98 | 80.12 | 0.00 | 0.00 |
| Maximum of Months | 385.07 | 201.70 | 254.66 | 170.52 | 118.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 98.81 | 208.12 | 94.75 | 32.89 | 61.86 | 0.00 | 0.00 |
| February | 121.64 | 178.18 | 108.85 | 34.83 | 74.02 | 0.00 | 0.00 |
| March | 141.88 | 150.88 | 114.39 | 30.11 | 84.28 | 0.00 | 0.00 |
| April | 207.91 | 94.16 | 139.23 | 39.08 | 100.14 | 0.00 | 0.00 |
| May | 268.21 | 19.96 | 132.36 | 25.22 | 107.14 | 0.00 | 0.00 |
| June | 309.77 | 16.04 | 148.52 | 32.26 | 116.25 | 0.00 | 0.00 |
| July | 295.37 | 8.50 | 139.54 | 22.28 | 117.26 | 0.00 | 0.00 |
| August | 280.45 | 14.94 | 133.45 | 22.59 | 110.86 | 0.00 | 0.00 |
| September | 233.60 | 25.02 | 119.29 | 22.80 | 96.49 | 0.00 | 0.00 |
| October | 209.26 | 53.43 | 113.74 | 29.23 | 84.52 | 0.00 | 0.00 |
| November | 123.56 | 131.75 | 93.09 | 29.24 | 63.85 | 0.00 | 0.00 |
| December | 100.57 | 176.23 | 87.47 | 29.78 | 57.70 | 0.00 | 0.00 |
| Annual Sum or Average | 199.68 | 89.29 | 118.74 | 29.13 | 89.61 | 0.00 | 0.00 |
| Minimum of Months | 98.81 | 8.50 | 87.47 | 22.28 | 57.70 | 0.00 | 0.00 |
| Maximum of Months | 309.77 | 208.12 | 148.52 | 39.08 | 117.26 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 341.86 | 199.20 | 251.33 | 167.07 | 84.27 | 0.00 | 0.00 |
| February | 337.31 | 170.99 | 242.44 | 146.77 | 95.67 | 0.00 | 0.00 |
| March | 267.11 | 145.99 | 186.96 | 85.85 | 101.11 | 0.00 | 0.00 |
| April | 267.59 | 93.01 | 168.50 | 58.98 | 109.52 | 0.00 | 0.00 |
| May | 297.54 | 19.40 | 149.38 | 39.80 | 109.58 | 0.00 | 0.00 |
| June | 308.32 | 15.68 | 149.61 | 34.84 | 114.78 | 0.00 | 0.00 |
| July | 312.75 | 7.98 | 149.53 | 31.71 | 117.82 | 0.00 | 0.00 |
| August | 320.88 | 14.70 | 153.98 | 35.00 | 118.97 | 0.00 | 0.00 |
| September | 317.64 | 24.83 | 162.66 | 49.19 | 113.47 | 0.00 | 0.00 |
| October | 380.89 | 53.09 | 209.88 | 101.51 | 108.37 | 0.00 | 0.00 |
| November | 372.05 | 128.84 | 245.01 | 158.32 | 86.69 | 0.00 | 0.00 |
| December | 341.52 | 173.50 | 237.66 | 158.22 | 79.44 | 0.00 | 0.00 |
| Annual Sum or Average | 322.06 | 86.82 | 191.95 | 88.61 | 103.34 | 0.00 | 0.00 |
| Minimum of Months | 267.11 | 7.98 | 149.38 | 31.71 | 79.44 | 0.00 | 0.00 |
| Maximum of Months | 380.89 | 199.20 | 251.33 | 167.07 | 118.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 85.49 | 200.15 | 91.43 | 29.44 | 61.99 | 0.00 | 0.00 |
| February | 106.32 | 170.70 | 103.64 | 30.63 | 73.01 | 0.00 | 0.00 |
| March | 146.21 | 144.49 | 121.46 | 36.18 | 85.29 | 0.00 | 0.00 |
| April | 201.28 | 91.42 | 137.46 | 37.75 | 99.70 | 0.00 | 0.00 |
| May | 291.68 | 19.30 | 147.05 | 39.22 | 107.83 | 0.00 | 0.00 |
| June | 322.96 | 15.42 | 156.51 | 38.97 | 117.54 | 0.00 | 0.00 |
| July | 315.85 | 8.14 | 151.45 | 33.01 | 118.43 | 0.00 | 0.00 |
| August | 286.64 | 14.28 | 138.00 | 26.94 | 111.07 | 0.00 | 0.00 |
| September | 234.49 | 24.16 | 120.62 | 23.25 | 97.37 | 0.00 | 0.00 |
| October | 204.67 | 51.01 | 113.11 | 28.42 | 84.69 | 0.00 | 0.00 |
| November | 117.19 | 124.97 | 94.21 | 30.25 | 63.96 | 0.00 | 0.00 |
| December | 81.15 | 172.39 | 78.22 | 21.20 | 57.02 | 0.00 | 0.00 |
| Annual Sum or Average | 200.05 | 85.92 | 121.17 | 31.26 | 89.91 | 0.00 | 0.00 |
| Minimum of Months | 81.15 | 8.14 | 78.22 | 21.20 | 57.02 | 0.00 | 0.00 |
| Maximum of Months | 322.96 | 200.15 | 156.51 | 39.22 | 118.43 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 24.48 | 134.14 | 33.86 | 0.00 | 33.86 | 0.00 | 0.00 |
| February | 32.87 | 114.51 | 39.94 | 0.00 | 39.94 | 0.00 | 0.00 |
| March | 48.46 | 95.74 | 46.35 | 0.00 | 46.34 | 0.00 | 0.00 |
| April | 75.77 | 58.71 | 54.83 | 0.32 | 54.51 | 0.00 | 0.00 |
| May | 132.29 | 11.56 | 62.05 | 2.34 | 59.72 | 0.00 | 0.00 |
| June | 155.88 | 9.15 | 70.35 | 4.79 | 65.56 | 0.00 | 0.00 |
| July | 152.74 | 4.89 | 68.32 | 2.55 | 65.77 | 0.00 | 0.00 |
| August | 137.24 | 8.55 | 61.44 | 0.63 | 60.81 | 0.00 | 0.00 |
| September | 108.46 | 14.79 | 52.90 | 0.01 | 52.89 | 0.00 | 0.00 |
| October | 86.99 | 32.84 | 45.95 | 0.00 | 45.95 | 0.00 | 0.00 |
| November | 38.34 | 83.69 | 34.88 | 0.00 | 34.88 | 0.00 | 0.00 |
| December | 26.64 | 112.99 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Annual Sum or Average | 85.34 | 56.49 | 50.25 | 0.89 | 49.36 | 0.00 | 0.00 |
| Minimum of Months | 24.48 | 4.89 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Maximum of Months | 155.88 | 134.14 | 70.35 | 4.79 | 65.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 24.42 | 134.06 | 33.86 | 0.00 | 33.86 | 0.00 | 0.00 |
| February | 32.80 | 114.43 | 39.94 | 0.00 | 39.94 | 0.00 | 0.00 |
| March | 48.35 | 95.69 | 46.35 | 0.00 | 46.34 | 0.00 | 0.00 |
| April | 75.70 | 58.66 | 54.83 | 0.32 | 54.51 | 0.00 | 0.00 |
| May | 132.26 | 11.54 | 62.05 | 2.34 | 59.72 | 0.00 | 0.00 |
| June | 155.86 | 9.14 | 70.35 | 4.79 | 65.56 | 0.00 | 0.00 |
| July | 152.71 | 4.89 | 68.32 | 2.55 | 65.77 | 0.00 | 0.00 |
| August | 137.22 | 8.54 | 61.44 | 0.63 | 60.81 | 0.00 | 0.00 |
| September | 108.44 | 14.78 | 52.90 | 0.01 | 52.89 | 0.00 | 0.00 |
| October | 86.97 | 32.79 | 45.95 | 0.00 | 45.95 | 0.00 | 0.00 |
| November | 38.26 | 83.61 | 34.88 | 0.00 | 34.88 | 0.00 | 0.00 |
| December | 26.60 | 112.87 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Annual Sum or Average | 85.29 | 56.44 | 50.25 | 0.89 | 49.36 | 0.00 | 0.00 |
| Minimum of Months | 24.42 | 4.89 | 31.47 | 0.00 | 31.47 | 0.00 | 0.00 |
| Maximum of Months | 155.86 | 134.06 | 70.35 | 4.79 | 65.77 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 280.27 | 123.97 | 193.76 | 137.63 | 56.13 | 0.00 | 0.00 |
| February | 262.90 | 107.13 | 178.74 | 116.14 | 62.61 | 0.00 | 0.00 |
| March | 169.27 | 93.67 | 111.84 | 49.67 | 62.17 | 0.00 | 0.00 |
| April | 143.50 | 60.21 | 85.87 | 21.55 | 64.32 | 0.00 | 0.00 |
| May | 138.57 | 11.96 | 64.39 | 2.92 | 61.47 | 0.00 | 0.00 |
| June | 141.27 | 9.66 | 63.46 | 0.66 | 62.80 | 0.00 | 0.00 |
| July | 149.67 | 4.79 | 66.40 | 1.25 | 65.15 | 0.00 | 0.00 |
| August | 172.04 | 9.04 | 77.41 | 8.70 | 68.71 | 0.00 | 0.00 |
| September | 192.57 | 15.22 | 94.94 | 25.95 | 68.99 | 0.00 | 0.00 |
| October | 264.83 | 33.26 | 142.72 | 73.10 | 69.63 | 0.00 | 0.00 |
| November | 293.19 | 80.44 | 185.68 | 128.07 | 57.62 | 0.00 | 0.00 |
| December | 288.45 | 107.65 | 190.91 | 137.01 | 53.89 | 0.00 | 0.00 |
| Annual Sum or Average | 207.76 | 54.47 | 121.02 | 58.24 | 62.78 | 0.00 | 0.00 |
| Minimum of Months | 138.57 | 4.79 | 63.46 | 0.66 | 53.89 | 0.00 | 0.00 |
| Maximum of Months | 293.19 | 123.97 | 193.76 | 137.63 | 69.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 280.18 | 123.90 | 193.76 | 137.63 | 56.13 | 0.00 | 0.00 |
| February | 262.82 | 107.05 | 178.74 | 116.14 | 62.61 | 0.00 | 0.00 |
| March | 169.17 | 93.62 | 111.84 | 49.67 | 62.17 | 0.00 | 0.00 |
| April | 143.44 | 60.17 | 85.87 | 21.55 | 64.32 | 0.00 | 0.00 |
| May | 138.54 | 11.95 | 64.39 | 2.92 | 61.47 | 0.00 | 0.00 |
| June | 141.24 | 9.65 | 63.46 | 0.66 | 62.80 | 0.00 | 0.00 |
| July | 149.65 | 4.78 | 66.40 | 1.25 | 65.15 | 0.00 | 0.00 |
| August | 172.03 | 9.03 | 77.41 | 8.70 | 68.71 | 0.00 | 0.00 |
| September | 192.56 | 15.20 | 94.94 | 25.95 | 68.99 | 0.00 | 0.00 |
| October | 264.81 | 33.23 | 142.72 | 73.10 | 69.63 | 0.00 | 0.00 |
| November | 293.13 | 80.40 | 185.68 | 128.07 | 57.62 | 0.00 | 0.00 |
| December | 288.41 | 107.58 | 190.91 | 137.01 | 53.89 | 0.00 | 0.00 |
| Annual Sum or Average | 207.72 | 54.43 | 121.02 | 58.24 | 62.78 | 0.00 | 0.00 |
| Minimum of Months | 138.54 | 4.78 | 63.46 | 0.66 | 53.89 | 0.00 | 0.00 |
| Maximum of Months | 293.13 | 123.90 | 193.76 | 137.63 | 69.63 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 16.00 | 21.78 | 13.81 | 7.06 | 6.75 | 0.00 | 0.00 |
| February | 18.60 | 18.71 | 15.28 | 7.35 | 7.93 | 0.00 | 0.00 |
| March | 23.93 | 15.98 | 18.02 | 8.68 | 9.34 | 0.00 | 0.00 |
| April | 29.59 | 10.74 | 19.83 | 8.98 | 10.85 | 0.00 | 0.00 |
| May | 36.60 | 3.38 | 20.40 | 8.85 | 11.55 | 0.00 | 0.00 |
| June | 38.53 | 2.96 | 20.67 | 8.20 | 12.47 | 0.00 | 0.00 |
| July | 37.24 | 1.97 | 19.95 | 7.31 | 12.64 | 0.00 | 0.00 |
| August | 34.03 | 2.78 | 18.37 | 6.31 | 12.06 | 0.00 | 0.00 |
| September | 28.68 | 4.03 | 16.25 | 5.58 | 10.67 | 0.00 | 0.00 |
| October | 26.95 | 6.94 | 16.12 | 6.82 | 9.30 | 0.00 | 0.00 |
| November | 19.22 | 14.54 | 14.24 | 7.26 | 6.98 | 0.00 | 0.00 |
| December | 13.37 | 19.21 | 11.22 | 5.09 | 6.13 | 0.00 | 0.00 |
| Annual Sum or Average | 26.94 | 10.21 | 17.02 | 7.29 | 9.73 | 0.00 | 0.00 |
| Minimum of Months | 13.37 | 1.97 | 11.22 | 5.09 | 6.13 | 0.00 | 0.00 |
| Maximum of Months | 38.53 | 21.78 | 20.67 | 8.98 | 12.64 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 47.73 | 65.87 | 41.14 | 21.04 | 20.11 | 0.00 | 0.00 |
| February | 56.10 | 55.37 | 45.52 | 21.89 | 23.63 | 0.00 | 0.00 |
| March | 72.18 | 47.56 | 53.68 | 25.85 | 27.83 | 0.00 | 0.00 |
| April | 88.72 | 32.09 | 59.05 | 26.75 | 32.30 | 0.00 | 0.00 |
| May | 108.19 | 11.30 | 60.74 | 26.36 | 34.39 | 0.00 | 0.00 |
| June | 113.21 | 10.34 | 61.57 | 24.43 | 37.15 | 0.00 | 0.00 |
| July | 108.74 | 7.77 | 59.41 | 21.77 | 37.64 | 0.00 | 0.00 |
| August | 99.03 | 10.57 | 54.72 | 18.80 | 35.92 | 0.00 | 0.00 |
| September | 83.58 | 14.57 | 48.40 | 16.61 | 31.79 | 0.00 | 0.00 |
| October | 78.70 | 23.59 | 48.00 | 20.31 | 27.69 | 0.00 | 0.00 |
| November | 55.61 | 46.62 | 42.40 | 21.62 | 20.78 | 0.00 | 0.00 |
| December | 38.94 | 60.27 | 33.41 | 15.15 | 18.25 | 0.00 | 0.00 |
| Annual Sum or Average | 79.35 | 32.04 | 50.69 | 21.71 | 28.98 | 0.00 | 0.00 |
| Minimum of Months | 38.94 | 7.77 | 33.41 | 15.15 | 18.25 | 0.00 | 0.00 |
| Maximum of Months | 113.21 | 65.87 | 61.57 | 26.75 | 37.64 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.04 | 24.32 | 13.81 | 7.06 | 6.75 | 0.00 | 0.00 |
| February | 17.63 | 20.86 | 15.28 | 7.35 | 7.93 | 0.00 | 0.00 |
| March | 23.06 | 17.88 | 18.02 | 8.68 | 9.34 | 0.00 | 0.00 |
| April | 29.22 | 11.44 | 19.83 | 8.98 | 10.85 | 0.00 | 0.00 |
| May | 37.24 | 3.29 | 20.40 | 8.85 | 11.55 | 0.00 | 0.00 |
| June | 39.26 | 2.85 | 20.67 | 8.20 | 12.47 | 0.00 | 0.00 |
| July | 38.02 | 1.87 | 19.95 | 7.31 | 12.64 | 0.00 | 0.00 |
| August | 34.75 | 2.70 | 18.37 | 6.31 | 12.06 | 0.00 | 0.00 |
| September | 29.19 | 4.03 | 16.25 | 5.58 | 10.67 | 0.00 | 0.00 |
| October | 27.09 | 7.30 | 16.12 | 6.82 | 9.30 | 0.00 | 0.00 |
| November | 18.28 | 16.22 | 14.24 | 7.26 | 6.98 | 0.00 | 0.00 |
| December | 12.52 | 21.74 | 11.22 | 5.09 | 6.13 | 0.00 | 0.00 |
| Annual Sum or Average | 26.83 | 11.16 | 17.02 | 7.29 | 9.73 | 0.00 | 0.00 |
| Minimum of Months | 12.52 | 1.87 | 11.22 | 5.09 | 6.13 | 0.00 | 0.00 |
| Maximum of Months | 39.26 | 24.32 | 20.67 | 8.98 | 12.64 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.941599E+09 | 0.592683E+09 | 0.682078E+09 | 0.456729E+09 | 0.225350E+09 | 0.00 | 0.00 |
| February | 0.855406E+09 | 0.447632E+09 | 0.599127E+09 | 0.365221E+09 | 0.233907E+09 | 0.00 | 0.00 |
| March | 0.715627E+09 | 0.424855E+09 | 0.481804E+09 | 0.213689E+09 | 0.268115E+09 | 0.00 | 0.00 |
| April | 0.734148E+09 | 0.256632E+09 | 0.441321E+09 | 0.156321E+09 | 0.285000E+09 | 0.00 | 0.00 |
| May | 0.762638E+09 | 53240362.81 | 0.360754E+09 | 69103708.33 | 0.291650E+09 | 0.00 | 0.00 |
| June | 0.792138E+09 | 42742336.64 | 0.367094E+09 | 72913976.44 | 0.294180E+09 | 0.00 | 0.00 |
| July | 0.805087E+09 | 24545552.82 | 0.368608E+09 | 56201476.21 | 0.312407E+09 | 0.00 | 0.00 |
| August | 0.860112E+09 | 47702397.69 | 0.400220E+09 | 82117847.38 | 0.318102E+09 | 0.00 | 0.00 |
| September | 0.835663E+09 | 75529583.42 | 0.418165E+09 | 0.126342E+09 | 0.291823E+09 | 0.00 | 0.00 |
| October | 0.104473E+10 | 0.165765E+09 | 0.563850E+09 | 0.274064E+09 | 0.289786E+09 | 0.00 | 0.00 |
| November | 0.969248E+09 | 0.380776E+09 | 0.632159E+09 | 0.407742E+09 | 0.224417E+09 | 0.00 | 0.00 |
| December | 0.960823E+09 | 0.525895E+09 | 0.661324E+09 | 0.446734E+09 | 0.214590E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.102772E+11 | 0.303800E+10 | 0.597650E+10 | 0.272718E+10 | 0.324933E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.715627E+09 | 24545552.82 | 0.360754E+09 | 56201476.21 | 0.214590E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.104473E+10 | 0.592683E+09 | 0.682078E+09 | 0.456729E+09 | 0.318102E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.267968E+09 | 0.590518E+09 | 0.253785E+09 | 88094626.44 | 0.165690E+09 | 0.00 | 0.00 |
| February | 0.305096E+09 | 0.446609E+09 | 0.263341E+09 | 84264227.65 | 0.179077E+09 | 0.00 | 0.00 |
| March | 0.395338E+09 | 0.419654E+09 | 0.306384E+09 | 80647891.77 | 0.225736E+09 | 0.00 | 0.00 |
| April | 0.559205E+09 | 0.250354E+09 | 0.360873E+09 | 0.101305E+09 | 0.259568E+09 | 0.00 | 0.00 |
| May | 0.745109E+09 | 51659159.48 | 0.354511E+09 | 67541717.01 | 0.286969E+09 | 0.00 | 0.00 |
| June | 0.829409E+09 | 41612839.36 | 0.384959E+09 | 83629160.20 | 0.301330E+09 | 0.00 | 0.00 |
| July | 0.813099E+09 | 24876552.06 | 0.373755E+09 | 59687626.65 | 0.314067E+09 | 0.00 | 0.00 |
| August | 0.766152E+09 | 46080686.00 | 0.357436E+09 | 60507999.00 | 0.296928E+09 | 0.00 | 0.00 |
| September | 0.616579E+09 | 72843650.25 | 0.309207E+09 | 59110265.69 | 0.250096E+09 | 0.00 | 0.00 |
| October | 0.565926E+09 | 0.163142E+09 | 0.304654E+09 | 78285677.91 | 0.226368E+09 | 0.00 | 0.00 |
| November | 0.311806E+09 | 0.393874E+09 | 0.241283E+09 | 75789925.26 | 0.165493E+09 | 0.00 | 0.00 |
| December | 0.265155E+09 | 0.523848E+09 | 0.234290E+09 | 79754632.26 | 0.154535E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.644084E+10 | 0.302507E+10 | 0.374448E+10 | 0.918619E+09 | 0.282586E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.265155E+09 | 24876552.06 | 0.234290E+09 | 59110265.69 | 0.154535E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.829409E+09 | 0.590518E+09 | 0.384959E+09 | 0.101305E+09 | 0.314067E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.898075E+09 | 0.633442E+09 | 0.673171E+09 | 0.447473E+09 | 0.225698E+09 | 0.00 | 0.00 |
| February | 0.813087E+09 | 0.478537E+09 | 0.586512E+09 | 0.355065E+09 | 0.231447E+09 | 0.00 | 0.00 |
| March | 0.709783E+09 | 0.461550E+09 | 0.500743E+09 | 0.229934E+09 | 0.270809E+09 | 0.00 | 0.00 |
| April | 0.677854E+09 | 0.309922E+09 | 0.436742E+09 | 0.152876E+09 | 0.283866E+09 | 0.00 | 0.00 |
| May | 0.742567E+09 | 0.138974E+09 | 0.400107E+09 | 0.106606E+09 | 0.293501E+09 | 0.00 | 0.00 |
| June | 0.741944E+09 | 0.127983E+09 | 0.387802E+09 | 90298454.01 | 0.297503E+09 | 0.00 | 0.00 |
| July | 0.748883E+09 | 0.115254E+09 | 0.400493E+09 | 84937032.06 | 0.315556E+09 | 0.00 | 0.00 |
| August | 0.785257E+09 | 0.146381E+09 | 0.412415E+09 | 93753151.42 | 0.318662E+09 | 0.00 | 0.00 |
| September | 0.757687E+09 | 0.183696E+09 | 0.421613E+09 | 0.127493E+09 | 0.294120E+09 | 0.00 | 0.00 |
| October | 0.967903E+09 | 0.276879E+09 | 0.562151E+09 | 0.271898E+09 | 0.290254E+09 | 0.00 | 0.00 |
| November | 0.930056E+09 | 0.454521E+09 | 0.635071E+09 | 0.410367E+09 | 0.224705E+09 | 0.00 | 0.00 |
| December | 0.887947E+09 | 0.587271E+09 | 0.636536E+09 | 0.423768E+09 | 0.212767E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.966104E+10 | 0.391441E+10 | 0.605336E+10 | 0.279447E+10 | 0.325889E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.677854E+09 | 0.115254E+09 | 0.387802E+09 | 84937032.06 | 0.212767E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.967903E+09 | 0.633442E+09 | 0.673171E+09 | 0.447473E+09 | 0.318662E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.229231E+09 | 0.567588E+09 | 0.244877E+09 | 78839041.99 | 0.166038E+09 | 0.00 | 0.00 |
| February | 0.264782E+09 | 0.426479E+09 | 0.250726E+09 | 74108536.14 | 0.176617E+09 | 0.00 | 0.00 |
| March | 0.405772E+09 | 0.400765E+09 | 0.325322E+09 | 96892699.66 | 0.228430E+09 | 0.00 | 0.00 |
| April | 0.540837E+09 | 0.242003E+09 | 0.356294E+09 | 97860358.53 | 0.258434E+09 | 0.00 | 0.00 |
| May | 0.809889E+09 | 50750248.58 | 0.393864E+09 | 0.105044E+09 | 0.288820E+09 | 0.00 | 0.00 |
| June | 0.864431E+09 | 40550317.36 | 0.405667E+09 | 0.101014E+09 | 0.304653E+09 | 0.00 | 0.00 |
| July | 0.868493E+09 | 24356473.89 | 0.405639E+09 | 88423182.50 | 0.317216E+09 | 0.00 | 0.00 |
| August | 0.783212E+09 | 44589961.43 | 0.369631E+09 | 72143303.05 | 0.297488E+09 | 0.00 | 0.00 |
| September | 0.619349E+09 | 70892674.60 | 0.312655E+09 | 60261676.10 | 0.252393E+09 | 0.00 | 0.00 |
| October | 0.553485E+09 | 0.156818E+09 | 0.302955E+09 | 76119207.32 | 0.226836E+09 | 0.00 | 0.00 |
| November | 0.290521E+09 | 0.372282E+09 | 0.244196E+09 | 78414852.08 | 0.165781E+09 | 0.00 | 0.00 |
| December | 0.209933E+09 | 0.510856E+09 | 0.209501E+09 | 56788907.17 | 0.152712E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.643993E+10 | 0.290793E+10 | 0.382133E+10 | 0.985910E+09 | 0.283542E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.209933E+09 | 24356473.89 | 0.209501E+09 | 56788907.17 | 0.152712E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.868493E+09 | 0.567588E+09 | 0.405667E+09 | 0.105044E+09 | 0.317216E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 65654953.93 | 0.383365E+09 | 90678595.30 | 0.00 | 90678595.30 | 0.00 | 0.00 |
| February | 82542625.91 | 0.287905E+09 | 96626007.49 | 0.00 | 96626007.49 | 0.00 | 0.00 |
| March | 0.134280E+09 | 0.268636E+09 | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.00 | 0.00 |
| April | 0.204092E+09 | 0.156058E+09 | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.00 | 0.00 |
| May | 0.366930E+09 | 30250250.47 | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.00 | 0.00 |
| June | 0.416690E+09 | 23839259.41 | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.00 | 0.00 |
| July | 0.419815E+09 | 14039405.20 | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.00 | 0.00 |
| August | 0.374949E+09 | 25501484.95 | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.00 | 0.00 |
| September | 0.286435E+09 | 41727019.94 | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.00 | 0.00 |
| October | 0.235000E+09 | 97958953.62 | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.00 | 0.00 |
| November | 94035529.80 | 0.248245E+09 | 90416797.23 | 0.00 | 90416797.23 | 0.00 | 0.00 |
| December | 67633042.59 | 0.338271E+09 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.274806E+10 | 0.191580E+10 | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.00 | 0.00 |
| Minimum of Months | 65654953.93 | 14039405.20 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Maximum of Months | 0.419815E+09 | 0.383365E+09 | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 65615952.49 | 0.383326E+09 | 90678595.30 | 0.00 | 90678595.30 | 0.00 | 0.00 |
| February | 82497433.92 | 0.287879E+09 | 96626007.49 | 0.00 | 96626007.49 | 0.00 | 0.00 |
| March | 0.134183E+09 | 0.268660E+09 | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.00 | 0.00 |
| April | 0.204031E+09 | 0.156051E+09 | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.00 | 0.00 |
| May | 0.366873E+09 | 30256378.94 | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.00 | 0.00 |
| June | 0.416649E+09 | 23837018.35 | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.00 | 0.00 |
| July | 0.419761E+09 | 14045455.01 | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.00 | 0.00 |
| August | 0.374925E+09 | 25493443.84 | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.00 | 0.00 |
| September | 0.286421E+09 | 41714250.13 | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.00 | 0.00 |
| October | 0.234982E+09 | 97932797.26 | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.00 | 0.00 |
| November | 93986919.70 | 0.248271E+09 | 90416797.23 | 0.00 | 90416797.23 | 0.00 | 0.00 |
| December | 67652555.36 | 0.338046E+09 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.274758E+10 | 0.191551E+10 | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.00 | 0.00 |
| Minimum of Months | 65615952.49 | 14045455.01 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Maximum of Months | 0.419761E+09 | 0.383326E+09 | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.749159E+09 | 0.366735E+09 | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.00 | 0.00 |
| February | 0.640609E+09 | 0.277570E+09 | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.00 | 0.00 |
| March | 0.459757E+09 | 0.266995E+09 | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.00 | 0.00 |
| April | 0.382115E+09 | 0.160458E+09 | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.00 | 0.00 |
| May | 0.384052E+09 | 31488841.11 | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.00 | 0.00 |
| June | 0.378467E+09 | 24934308.19 | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.00 | 0.00 |
| July | 0.411441E+09 | 13811213.41 | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.00 | 0.00 |
| August | 0.469619E+09 | 26966164.20 | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.00 | 0.00 |
| September | 0.507236E+09 | 43591443.74 | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.00 | 0.00 |
| October | 0.717705E+09 | 98025020.45 | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.00 | 0.00 |
| November | 0.761190E+09 | 0.228988E+09 | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.00 | 0.00 |
| December | 0.770999E+09 | 0.323698E+09 | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.663235E+10 | 0.186326E+10 | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.378467E+09 | 13811213.41 | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.770999E+09 | 0.366735E+09 | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.748026E+09 | 0.368525E+09 | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.00 | 0.00 |
| February | 0.639721E+09 | 0.278809E+09 | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.00 | 0.00 |
| March | 0.458483E+09 | 0.269026E+09 | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.00 | 0.00 |
| April | 0.380812E+09 | 0.162082E+09 | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.00 | 0.00 |
| May | 0.381342E+09 | 33388531.68 | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.00 | 0.00 |
| June | 0.375673E+09 | 26678533.39 | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.00 | 0.00 |
| July | 0.407734E+09 | 15256484.63 | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.00 | 0.00 |
| August | 0.466606E+09 | 28813989.10 | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.00 | 0.00 |
| September | 0.504863E+09 | 45931829.43 | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.00 | 0.00 |
| October | 0.715650E+09 | 0.100394E+09 | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.00 | 0.00 |
| November | 0.760035E+09 | 0.230695E+09 | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.00 | 0.00 |
| December | 0.769872E+09 | 0.325711E+09 | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.660882E+10 | 0.188531E+10 | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.375673E+09 | 15256484.63 | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.769872E+09 | 0.368525E+09 | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.934322E+09 | 0.594949E+09 | 0.682078E+09 | 0.456729E+09 | 0.225350E+09 | 0.00 | 0.00 |
| February | 0.840498E+09 | 0.462704E+09 | 0.599127E+09 | 0.365221E+09 | 0.233907E+09 | 0.00 | 0.00 |
| March | 0.698155E+09 | 0.445792E+09 | 0.481804E+09 | 0.213689E+09 | 0.268115E+09 | 0.00 | 0.00 |
| April | 0.720913E+09 | 0.268887E+09 | 0.441321E+09 | 0.156321E+09 | 0.285000E+09 | 0.00 | 0.00 |
| May | 0.756732E+09 | 55497773.03 | 0.360754E+09 | 69103708.33 | 0.291650E+09 | 0.00 | 0.00 |
| June | 0.788940E+09 | 43303977.02 | 0.367094E+09 | 72913976.44 | 0.294180E+09 | 0.00 | 0.00 |
| July | 0.807262E+09 | 22815791.14 | 0.368608E+09 | 56201476.21 | 0.312407E+09 | 0.00 | 0.00 |
| August | 0.866805E+09 | 42060709.76 | 0.400220E+09 | 82117847.38 | 0.318102E+09 | 0.00 | 0.00 |
| September | 0.840312E+09 | 67820750.67 | 0.418165E+09 | 0.126342E+09 | 0.291823E+09 | 0.00 | 0.00 |
| October | 0.104740E+10 | 0.157509E+09 | 0.563850E+09 | 0.274064E+09 | 0.289786E+09 | 0.00 | 0.00 |
| November | 0.967864E+09 | 0.374882E+09 | 0.632159E+09 | 0.407742E+09 | 0.224417E+09 | 0.00 | 0.00 |
| December | 0.958171E+09 | 0.519410E+09 | 0.661324E+09 | 0.446734E+09 | 0.214590E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.102274E+11 | 0.305563E+10 | 0.597650E+10 | 0.272718E+10 | 0.324933E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.698155E+09 | 22815791.14 | 0.360754E+09 | 56201476.21 | 0.214590E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.104740E+10 | 0.594949E+09 | 0.682078E+09 | 0.456729E+09 | 0.318102E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.263784E+09 | 0.597476E+09 | 0.253785E+09 | 88094626.44 | 0.165690E+09 | 0.00 | 0.00 |
| February | 0.291706E+09 | 0.470079E+09 | 0.263341E+09 | 84264227.65 | 0.179077E+09 | 0.00 | 0.00 |
| March | 0.377862E+09 | 0.447227E+09 | 0.306384E+09 | 80647891.77 | 0.225736E+09 | 0.00 | 0.00 |
| April | 0.545616E+09 | 0.265308E+09 | 0.360873E+09 | 0.101305E+09 | 0.259568E+09 | 0.00 | 0.00 |
| May | 0.739287E+09 | 53755924.56 | 0.354511E+09 | 67541717.01 | 0.286969E+09 | 0.00 | 0.00 |
| June | 0.826390E+09 | 41834286.57 | 0.384959E+09 | 83629160.20 | 0.301330E+09 | 0.00 | 0.00 |
| July | 0.815349E+09 | 23076261.36 | 0.373755E+09 | 59687626.65 | 0.314067E+09 | 0.00 | 0.00 |
| August | 0.773506E+09 | 40489932.25 | 0.357436E+09 | 60507999.00 | 0.296928E+09 | 0.00 | 0.00 |
| September | 0.622363E+09 | 65765910.91 | 0.309207E+09 | 59110265.69 | 0.250096E+09 | 0.00 | 0.00 |
| October | 0.571109E+09 | 0.155416E+09 | 0.304654E+09 | 78285677.91 | 0.226368E+09 | 0.00 | 0.00 |
| November | 0.313588E+09 | 0.388060E+09 | 0.241283E+09 | 75789925.26 | 0.165493E+09 | 0.00 | 0.00 |
| December | 0.265727E+09 | 0.519654E+09 | 0.234290E+09 | 79754632.26 | 0.154535E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.640629E+10 | 0.306814E+10 | 0.374448E+10 | 0.918619E+09 | 0.282586E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.263784E+09 | 23076261.36 | 0.234290E+09 | 59110265.69 | 0.154535E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.826390E+09 | 0.597476E+09 | 0.384959E+09 | 0.101305E+09 | 0.314067E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.910622E+09 | 0.588700E+09 | 0.673171E+09 | 0.447473E+09 | 0.225698E+09 | 0.00 | 0.00 |
| February | 0.812690E+09 | 0.455211E+09 | 0.586512E+09 | 0.355065E+09 | 0.231447E+09 | 0.00 | 0.00 |
| March | 0.713809E+09 | 0.432620E+09 | 0.500743E+09 | 0.229934E+09 | 0.270809E+09 | 0.00 | 0.00 |
| April | 0.701817E+09 | 0.259165E+09 | 0.436742E+09 | 0.152876E+09 | 0.283866E+09 | 0.00 | 0.00 |
| May | 0.819568E+09 | 52790482.22 | 0.400107E+09 | 0.106606E+09 | 0.293501E+09 | 0.00 | 0.00 |
| June | 0.822828E+09 | 41052554.21 | 0.387802E+09 | 90298454.01 | 0.297503E+09 | 0.00 | 0.00 |
| July | 0.862421E+09 | 21890697.71 | 0.400493E+09 | 84937032.06 | 0.315556E+09 | 0.00 | 0.00 |
| August | 0.883527E+09 | 40214645.22 | 0.412415E+09 | 93753151.42 | 0.318662E+09 | 0.00 | 0.00 |
| September | 0.843145E+09 | 65925423.03 | 0.421613E+09 | 0.127493E+09 | 0.294120E+09 | 0.00 | 0.00 |
| October | 0.103668E+10 | 0.153269E+09 | 0.562151E+09 | 0.271898E+09 | 0.290254E+09 | 0.00 | 0.00 |
| November | 0.963648E+09 | 0.369904E+09 | 0.635071E+09 | 0.410367E+09 | 0.224705E+09 | 0.00 | 0.00 |
| December | 0.911851E+09 | 0.517190E+09 | 0.636536E+09 | 0.423768E+09 | 0.212767E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.102826E+11 | 0.299793E+10 | 0.605336E+10 | 0.279447E+10 | 0.325889E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.701817E+09 | 21890697.71 | 0.387802E+09 | 84937032.06 | 0.212767E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.103668E+10 | 0.588700E+09 | 0.673171E+09 | 0.447473E+09 | 0.318662E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.224685E+09 | 0.573615E+09 | 0.244877E+09 | 78839041.99 | 0.166038E+09 | 0.00 | 0.00 |
| February | 0.251029E+09 | 0.449562E+09 | 0.250726E+09 | 74108536.14 | 0.176617E+09 | 0.00 | 0.00 |
| March | 0.386531E+09 | 0.427130E+09 | 0.325322E+09 | 96892699.66 | 0.228430E+09 | 0.00 | 0.00 |
| April | 0.526652E+09 | 0.256008E+09 | 0.356294E+09 | 97860358.53 | 0.258434E+09 | 0.00 | 0.00 |
| May | 0.803592E+09 | 52468554.26 | 0.393864E+09 | 0.105044E+09 | 0.288820E+09 | 0.00 | 0.00 |
| June | 0.861303E+09 | 40572237.11 | 0.405667E+09 | 0.101014E+09 | 0.304653E+09 | 0.00 | 0.00 |
| July | 0.870715E+09 | 22327723.43 | 0.405639E+09 | 88423182.50 | 0.317216E+09 | 0.00 | 0.00 |
| August | 0.790580E+09 | 38986151.85 | 0.369631E+09 | 72143303.05 | 0.297488E+09 | 0.00 | 0.00 |
| September | 0.625174E+09 | 63808612.71 | 0.312655E+09 | 60261676.10 | 0.252393E+09 | 0.00 | 0.00 |
| October | 0.558564E+09 | 0.149067E+09 | 0.302955E+09 | 76119207.32 | 0.226836E+09 | 0.00 | 0.00 |
| November | 0.292176E+09 | 0.366823E+09 | 0.244196E+09 | 78414852.08 | 0.165781E+09 | 0.00 | 0.00 |
| December | 0.210482E+09 | 0.506456E+09 | 0.209501E+09 | 56788907.17 | 0.152712E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.640148E+10 | 0.294683E+10 | 0.382133E+10 | 0.985910E+09 | 0.283542E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.210482E+09 | 22327723.43 | 0.209501E+09 | 56788907.17 | 0.152712E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.870715E+09 | 0.573615E+09 | 0.405667E+09 | 0.105044E+09 | 0.317216E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 63546339.50 | 0.388948E+09 | 90678595.30 | 0.00 | 90678595.30 | 0.00 | 0.00 |
| February | 76727776.43 | 0.303668E+09 | 96626007.49 | 0.00 | 96626007.49 | 0.00 | 0.00 |
| March | 0.126488E+09 | 0.284353E+09 | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.00 | 0.00 |
| April | 0.199088E+09 | 0.162603E+09 | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.00 | 0.00 |
| May | 0.365347E+09 | 30595970.81 | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.00 | 0.00 |
| June | 0.416429E+09 | 23421822.88 | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.00 | 0.00 |
| July | 0.421970E+09 | 12916027.73 | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.00 | 0.00 |
| August | 0.379264E+09 | 22725760.43 | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.00 | 0.00 |
| September | 0.289772E+09 | 38239601.66 | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.00 | 0.00 |
| October | 0.237870E+09 | 94607623.53 | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.00 | 0.00 |
| November | 94589019.10 | 0.247134E+09 | 90416797.23 | 0.00 | 90416797.23 | 0.00 | 0.00 |
| December | 67718751.34 | 0.338434E+09 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.273881E+10 | 0.194765E+10 | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.00 | 0.00 |
| Minimum of Months | 63546339.50 | 12916027.73 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Maximum of Months | 0.421970E+09 | 0.388948E+09 | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 63502286.18 | 0.388869E+09 | 90678595.30 | 0.00 | 90678595.30 | 0.00 | 0.00 |
| February | 76668644.13 | 0.303659E+09 | 96626007.49 | 0.00 | 96626007.49 | 0.00 | 0.00 |
| March | 0.126374E+09 | 0.284406E+09 | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.00 | 0.00 |
| April | 0.199039E+09 | 0.162582E+09 | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.00 | 0.00 |
| May | 0.365301E+09 | 30592761.05 | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.00 | 0.00 |
| June | 0.416395E+09 | 23414277.94 | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.00 | 0.00 |
| July | 0.421927E+09 | 12916158.33 | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.00 | 0.00 |
| August | 0.379242E+09 | 22715172.51 | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.00 | 0.00 |
| September | 0.289757E+09 | 38225712.83 | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.00 | 0.00 |
| October | 0.237848E+09 | 94577818.20 | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.00 | 0.00 |
| November | 94525347.75 | 0.247162E+09 | 90416797.23 | 0.00 | 90416797.23 | 0.00 | 0.00 |
| December | 67730543.81 | 0.338182E+09 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.273831E+10 | 0.194730E+10 | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.00 | 0.00 |
| Minimum of Months | 63502286.18 | 12916158.33 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Maximum of Months | 0.421927E+09 | 0.388869E+09 | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.743434E+09 | 0.369204E+09 | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.00 | 0.00 |
| February | 0.632478E+09 | 0.284630E+09 | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.00 | 0.00 |
| March | 0.451065E+09 | 0.277214E+09 | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.00 | 0.00 |
| April | 0.376835E+09 | 0.165395E+09 | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.00 | 0.00 |
| May | 0.382461E+09 | 31814139.01 | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.00 | 0.00 |
| June | 0.378235E+09 | 24655634.66 | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.00 | 0.00 |
| July | 0.413811E+09 | 12642345.20 | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.00 | 0.00 |
| August | 0.473387E+09 | 24087419.55 | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.00 | 0.00 |
| September | 0.509504E+09 | 39592153.03 | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.00 | 0.00 |
| October | 0.718256E+09 | 94007711.90 | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.00 | 0.00 |
| November | 0.759105E+09 | 0.226576E+09 | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.00 | 0.00 |
| December | 0.768070E+09 | 0.321367E+09 | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.660664E+10 | 0.187119E+10 | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.376835E+09 | 12642345.20 | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.768070E+09 | 0.369204E+09 | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.743351E+09 | 0.369194E+09 | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.00 | 0.00 |
| February | 0.632423E+09 | 0.284590E+09 | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.00 | 0.00 |
| March | 0.450968E+09 | 0.277227E+09 | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.00 | 0.00 |
| April | 0.376795E+09 | 0.165367E+09 | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.00 | 0.00 |
| May | 0.382415E+09 | 31811023.25 | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.00 | 0.00 |
| June | 0.378200E+09 | 24647304.62 | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.00 | 0.00 |
| July | 0.413768E+09 | 12642360.68 | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.00 | 0.00 |
| August | 0.473365E+09 | 24076534.89 | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.00 | 0.00 |
| September | 0.509489E+09 | 39578193.40 | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.00 | 0.00 |
| October | 0.718240E+09 | 93982006.70 | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.00 | 0.00 |
| November | 0.759073E+09 | 0.226554E+09 | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.00 | 0.00 |
| December | 0.768067E+09 | 0.321272E+09 | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.660615E+10 | 0.187094E+10 | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.376795E+09 | 12642360.68 | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.768067E+09 | 0.369194E+09 | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.938966E+09 | 0.540242E+09 | 0.682078E+09 | 0.456729E+09 | 0.225350E+09 | 0.00 | 0.00 |
| February | 0.842804E+09 | 0.420479E+09 | 0.599127E+09 | 0.365221E+09 | 0.233907E+09 | 0.00 | 0.00 |
| March | 0.698359E+09 | 0.402047E+09 | 0.481804E+09 | 0.213689E+09 | 0.268115E+09 | 0.00 | 0.00 |
| April | 0.711077E+09 | 0.248595E+09 | 0.441321E+09 | 0.156321E+09 | 0.285000E+09 | 0.00 | 0.00 |
| May | 0.735414E+09 | 54941127.36 | 0.360754E+09 | 69103708.33 | 0.291650E+09 | 0.00 | 0.00 |
| June | 0.765858E+09 | 43037678.58 | 0.367094E+09 | 72913976.44 | 0.294180E+09 | 0.00 | 0.00 |
| July | 0.782968E+09 | 22423433.82 | 0.368608E+09 | 56201476.21 | 0.312407E+09 | 0.00 | 0.00 |
| August | 0.843154E+09 | 41417962.76 | 0.400220E+09 | 82117847.38 | 0.318102E+09 | 0.00 | 0.00 |
| September | 0.820983E+09 | 66503127.65 | 0.418165E+09 | 0.126342E+09 | 0.291823E+09 | 0.00 | 0.00 |
| October | 0.103137E+10 | 0.146639E+09 | 0.563850E+09 | 0.274064E+09 | 0.289786E+09 | 0.00 | 0.00 |
| November | 0.969125E+09 | 0.338386E+09 | 0.632159E+09 | 0.407742E+09 | 0.224417E+09 | 0.00 | 0.00 |
| December | 0.961686E+09 | 0.467655E+09 | 0.661324E+09 | 0.446734E+09 | 0.214590E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.101018E+11 | 0.279237E+10 | 0.597650E+10 | 0.272718E+10 | 0.324933E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.698359E+09 | 22423433.82 | 0.360754E+09 | 56201476.21 | 0.214590E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.103137E+10 | 0.540242E+09 | 0.682078E+09 | 0.456729E+09 | 0.318102E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.264646E+09 | 0.557430E+09 | 0.253785E+09 | 88094626.44 | 0.165690E+09 | 0.00 | 0.00 |
| February | 0.294271E+09 | 0.431050E+09 | 0.263341E+09 | 84264227.65 | 0.179077E+09 | 0.00 | 0.00 |
| March | 0.380012E+09 | 0.404130E+09 | 0.306384E+09 | 80647891.77 | 0.225736E+09 | 0.00 | 0.00 |
| April | 0.538905E+09 | 0.244074E+09 | 0.360873E+09 | 0.101305E+09 | 0.259568E+09 | 0.00 | 0.00 |
| May | 0.718381E+09 | 53450754.33 | 0.354511E+09 | 67541717.01 | 0.286969E+09 | 0.00 | 0.00 |
| June | 0.802935E+09 | 41581062.18 | 0.384959E+09 | 83629160.20 | 0.301330E+09 | 0.00 | 0.00 |
| July | 0.791131E+09 | 22758619.75 | 0.373755E+09 | 59687626.65 | 0.314067E+09 | 0.00 | 0.00 |
| August | 0.751154E+09 | 40010937.26 | 0.357436E+09 | 60507999.00 | 0.296928E+09 | 0.00 | 0.00 |
| September | 0.605486E+09 | 64840248.71 | 0.309207E+09 | 59110265.69 | 0.250096E+09 | 0.00 | 0.00 |
| October | 0.560478E+09 | 0.143112E+09 | 0.304654E+09 | 78285677.91 | 0.226368E+09 | 0.00 | 0.00 |
| November | 0.320280E+09 | 0.341504E+09 | 0.241283E+09 | 75789925.26 | 0.165493E+09 | 0.00 | 0.00 |
| December | 0.269358E+09 | 0.472010E+09 | 0.234290E+09 | 79754632.26 | 0.154535E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.629704E+10 | 0.281595E+10 | 0.374448E+10 | 0.918619E+09 | 0.282586E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.264646E+09 | 22758619.75 | 0.234290E+09 | 59110265.69 | 0.154535E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.802935E+09 | 0.557430E+09 | 0.384959E+09 | 0.101305E+09 | 0.314067E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.915642E+09 | 0.533532E+09 | 0.673171E+09 | 0.447473E+09 | 0.225698E+09 | 0.00 | 0.00 |
| February | 0.816028E+09 | 0.413660E+09 | 0.586512E+09 | 0.355065E+09 | 0.231447E+09 | 0.00 | 0.00 |
| March | 0.715432E+09 | 0.391033E+09 | 0.500743E+09 | 0.229934E+09 | 0.270809E+09 | 0.00 | 0.00 |
| April | 0.693601E+09 | 0.241077E+09 | 0.436742E+09 | 0.152876E+09 | 0.283866E+09 | 0.00 | 0.00 |
| May | 0.796933E+09 | 51958634.23 | 0.400107E+09 | 0.106606E+09 | 0.293501E+09 | 0.00 | 0.00 |
| June | 0.799167E+09 | 40630114.47 | 0.387802E+09 | 90298454.01 | 0.297503E+09 | 0.00 | 0.00 |
| July | 0.837663E+09 | 21384226.71 | 0.400493E+09 | 84937032.06 | 0.315556E+09 | 0.00 | 0.00 |
| August | 0.859439E+09 | 39368724.03 | 0.412415E+09 | 93753151.42 | 0.318662E+09 | 0.00 | 0.00 |
| September | 0.823333E+09 | 64354067.88 | 0.421613E+09 | 0.127493E+09 | 0.294120E+09 | 0.00 | 0.00 |
| October | 0.102017E+10 | 0.142206E+09 | 0.562151E+09 | 0.271898E+09 | 0.290254E+09 | 0.00 | 0.00 |
| November | 0.964359E+09 | 0.333962E+09 | 0.635071E+09 | 0.410367E+09 | 0.224705E+09 | 0.00 | 0.00 |
| December | 0.914729E+09 | 0.464691E+09 | 0.636536E+09 | 0.423768E+09 | 0.212767E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.101565E+11 | 0.273786E+10 | 0.605336E+10 | 0.279447E+10 | 0.325889E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.693601E+09 | 21384226.71 | 0.387802E+09 | 84937032.06 | 0.212767E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.102017E+10 | 0.533532E+09 | 0.673171E+09 | 0.447473E+09 | 0.318662E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.228985E+09 | 0.536091E+09 | 0.244877E+09 | 78839041.99 | 0.166038E+09 | 0.00 | 0.00 |
| February | 0.257217E+09 | 0.412958E+09 | 0.250726E+09 | 74108536.14 | 0.176617E+09 | 0.00 | 0.00 |
| March | 0.391603E+09 | 0.387001E+09 | 0.325322E+09 | 96892699.66 | 0.228430E+09 | 0.00 | 0.00 |
| April | 0.521717E+09 | 0.236969E+09 | 0.356294E+09 | 97860358.53 | 0.258434E+09 | 0.00 | 0.00 |
| May | 0.781232E+09 | 51679824.73 | 0.393864E+09 | 0.105044E+09 | 0.288820E+09 | 0.00 | 0.00 |
| June | 0.837120E+09 | 39981580.85 | 0.405667E+09 | 0.101014E+09 | 0.304653E+09 | 0.00 | 0.00 |
| July | 0.845960E+09 | 21799351.79 | 0.405639E+09 | 88423182.50 | 0.317216E+09 | 0.00 | 0.00 |
| August | 0.767743E+09 | 38241557.67 | 0.369631E+09 | 72143303.05 | 0.297488E+09 | 0.00 | 0.00 |
| September | 0.607807E+09 | 62615574.15 | 0.312655E+09 | 60261676.10 | 0.252393E+09 | 0.00 | 0.00 |
| October | 0.548199E+09 | 0.136612E+09 | 0.302955E+09 | 76119207.32 | 0.226836E+09 | 0.00 | 0.00 |
| November | 0.303746E+09 | 0.323918E+09 | 0.244196E+09 | 78414852.08 | 0.165781E+09 | 0.00 | 0.00 |
| December | 0.217363E+09 | 0.461724E+09 | 0.209501E+09 | 56788907.17 | 0.152712E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.630869E+10 | 0.270959E+10 | 0.382133E+10 | 0.985910E+09 | 0.283542E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.217363E+09 | 21799351.79 | 0.209501E+09 | 56788907.17 | 0.152712E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.845960E+09 | 0.536091E+09 | 0.405667E+09 | 0.105044E+09 | 0.317216E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 65564351.36 | 0.359279E+09 | 90678595.30 | 0.00 | 90678595.30 | 0.00 | 0.00 |
| February | 79525714.22 | 0.277032E+09 | 96626007.49 | 0.00 | 96626007.49 | 0.00 | 0.00 |
| March | 0.129790E+09 | 0.256430E+09 | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.00 | 0.00 |
| April | 0.196389E+09 | 0.152187E+09 | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.00 | 0.00 |
| May | 0.354315E+09 | 30950085.83 | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.00 | 0.00 |
| June | 0.404046E+09 | 23726430.49 | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.00 | 0.00 |
| July | 0.409092E+09 | 13099559.77 | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.00 | 0.00 |
| August | 0.367579E+09 | 22902026.78 | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.00 | 0.00 |
| September | 0.281126E+09 | 38338512.21 | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.00 | 0.00 |
| October | 0.233004E+09 | 87970516.51 | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.00 | 0.00 |
| November | 99374232.11 | 0.216916E+09 | 90416797.23 | 0.00 | 90416797.23 | 0.00 | 0.00 |
| December | 71353726.55 | 0.302645E+09 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269116E+10 | 0.178148E+10 | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.00 | 0.00 |
| Minimum of Months | 65564351.36 | 13099559.77 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Maximum of Months | 0.409092E+09 | 0.359279E+09 | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 65404772.52 | 0.359060E+09 | 90678595.30 | 0.00 | 90678595.30 | 0.00 | 0.00 |
| February | 79356610.19 | 0.276823E+09 | 96626007.49 | 0.00 | 96626007.49 | 0.00 | 0.00 |
| March | 0.129503E+09 | 0.256284E+09 | 0.124130E+09 | 5803.94 | 0.124125E+09 | 0.00 | 0.00 |
| April | 0.196203E+09 | 0.152058E+09 | 0.142122E+09 | 840666.33 | 0.141281E+09 | 0.00 | 0.00 |
| May | 0.354232E+09 | 30920579.22 | 0.166207E+09 | 6258646.27 | 0.159949E+09 | 0.00 | 0.00 |
| June | 0.403984E+09 | 23696368.05 | 0.182344E+09 | 12415345.12 | 0.169929E+09 | 0.00 | 0.00 |
| July | 0.409026E+09 | 13087072.10 | 0.182987E+09 | 6829226.80 | 0.176158E+09 | 0.00 | 0.00 |
| August | 0.367537E+09 | 22871430.98 | 0.164557E+09 | 1694359.18 | 0.162863E+09 | 0.00 | 0.00 |
| September | 0.281089E+09 | 38299844.90 | 0.137122E+09 | 26670.12 | 0.137095E+09 | 0.00 | 0.00 |
| October | 0.232940E+09 | 87836871.05 | 0.123071E+09 | 0.00 | 0.123071E+09 | 0.00 | 0.00 |
| November | 99157130.71 | 0.216729E+09 | 90416797.23 | 0.00 | 90416797.23 | 0.00 | 0.00 |
| December | 71242083.87 | 0.302324E+09 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268967E+10 | 0.177999E+10 | 0.158456E+10 | 28070717.76 | 0.155649E+10 | 0.00 | 0.00 |
| Minimum of Months | 65404772.52 | 13087072.10 | 84296073.93 | 0.00 | 84296073.93 | 0.00 | 0.00 |
| Maximum of Months | 0.409026E+09 | 0.359060E+09 | 0.182987E+09 | 12415345.12 | 0.176158E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.750664E+09 | 0.332042E+09 | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.00 | 0.00 |
| February | 0.635996E+09 | 0.259164E+09 | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.00 | 0.00 |
| March | 0.453372E+09 | 0.250882E+09 | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.00 | 0.00 |
| April | 0.371957E+09 | 0.156072E+09 | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.00 | 0.00 |
| May | 0.371159E+09 | 32046654.50 | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.00 | 0.00 |
| June | 0.366165E+09 | 25034373.70 | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.00 | 0.00 |
| July | 0.400886E+09 | 12819146.27 | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.00 | 0.00 |
| August | 0.460799E+09 | 24205564.67 | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.00 | 0.00 |
| September | 0.499139E+09 | 39437606.27 | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.00 | 0.00 |
| October | 0.709328E+09 | 89089062.38 | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.00 | 0.00 |
| November | 0.759945E+09 | 0.208497E+09 | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.00 | 0.00 |
| December | 0.772590E+09 | 0.288333E+09 | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.655200E+10 | 0.171762E+10 | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.366165E+09 | 12819146.27 | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.772590E+09 | 0.332042E+09 | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.750430E+09 | 0.331861E+09 | 0.518972E+09 | 0.368634E+09 | 0.150338E+09 | 0.00 | 0.00 |
| February | 0.635822E+09 | 0.258986E+09 | 0.432412E+09 | 0.280956E+09 | 0.151456E+09 | 0.00 | 0.00 |
| March | 0.453108E+09 | 0.250753E+09 | 0.299551E+09 | 0.133047E+09 | 0.166504E+09 | 0.00 | 0.00 |
| April | 0.371802E+09 | 0.155952E+09 | 0.222570E+09 | 55856672.97 | 0.166713E+09 | 0.00 | 0.00 |
| May | 0.371072E+09 | 32016207.44 | 0.172450E+09 | 7820637.59 | 0.164629E+09 | 0.00 | 0.00 |
| June | 0.366097E+09 | 25002352.66 | 0.164479E+09 | 1700161.35 | 0.162779E+09 | 0.00 | 0.00 |
| July | 0.400817E+09 | 12805676.30 | 0.177841E+09 | 3343076.35 | 0.174498E+09 | 0.00 | 0.00 |
| August | 0.460757E+09 | 24174358.01 | 0.207341E+09 | 23304207.56 | 0.184037E+09 | 0.00 | 0.00 |
| September | 0.499103E+09 | 39399356.83 | 0.246080E+09 | 67258100.01 | 0.178822E+09 | 0.00 | 0.00 |
| October | 0.709271E+09 | 89008382.88 | 0.382267E+09 | 0.195778E+09 | 0.186489E+09 | 0.00 | 0.00 |
| November | 0.759797E+09 | 0.208389E+09 | 0.481292E+09 | 0.331952E+09 | 0.149340E+09 | 0.00 | 0.00 |
| December | 0.772484E+09 | 0.288140E+09 | 0.511330E+09 | 0.366979E+09 | 0.144351E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.655056E+10 | 0.171649E+10 | 0.381659E+10 | 0.183663E+10 | 0.197996E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.366097E+09 | 12805676.30 | 0.164479E+09 | 1700161.35 | 0.144351E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.772484E+09 | 0.331861E+09 | 0.518972E+09 | 0.368634E+09 | 0.186489E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 42842935.81 | 58346153.85 | 37000590.41 | 18917749.03 | 18082841.38 | 0.00 | 0.00 |
| February | 45005212.09 | 45273204.61 | 36976834.69 | 17782644.90 | 19194189.79 | 0.00 | 0.00 |
| March | 64100243.29 | 42813926.74 | 48276830.86 | 23248405.00 | 25028425.86 | 0.00 | 0.00 |
| April | 76704098.65 | 27833681.87 | 51391516.41 | 23280270.05 | 28111246.36 | 0.00 | 0.00 |
| May | 98030789.38 | 9061869.24 | 54627221.13 | 23704006.26 | 30923214.88 | 0.00 | 0.00 |
| June | 99869963.46 | 7678003.98 | 53587221.80 | 21259520.96 | 32327700.85 | 0.00 | 0.00 |
| July | 99742715.86 | 5278786.72 | 53426268.34 | 19578801.79 | 33847466.55 | 0.00 | 0.00 |
| August | 91157481.24 | 7450244.60 | 49208437.11 | 16904510.83 | 32303926.28 | 0.00 | 0.00 |
| September | 74333606.49 | 10438535.10 | 42119847.63 | 14453634.87 | 27666212.77 | 0.00 | 0.00 |
| October | 72194079.71 | 18576303.07 | 43163945.43 | 18265113.63 | 24898831.79 | 0.00 | 0.00 |
| November | 49827567.32 | 37687363.55 | 36899906.01 | 18815962.94 | 18083943.08 | 0.00 | 0.00 |
| December | 35797497.09 | 51454753.92 | 30043510.79 | 13626729.43 | 16416781.36 | 0.00 | 0.00 |
| Annual Sum or Average | 0.849606E+09 | 0.321893E+09 | 0.536722E+09 | 0.229837E+09 | 0.306885E+09 | 0.00 | 0.00 |
| Minimum of Months | 35797497.09 | 5278786.72 | 30043510.79 | 13626729.43 | 16416781.36 | 0.00 | 0.00 |
| Maximum of Months | 99869963.46 | 58346153.85 | 54627221.13 | 23704006.26 | 33847466.55 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.127847E+09 | 0.176430E+09 | 0.110197E+09 | 56341764.55 | 53855201.78 | 0.00 | 0.00 |
| February | 0.135710E+09 | 0.133947E+09 | 0.110126E+09 | 52961141.95 | 57165073.93 | 0.00 | 0.00 |
| March | 0.193339E+09 | 0.127388E+09 | 0.143780E+09 | 69239535.76 | 74540880.88 | 0.00 | 0.00 |
| April | 0.229975E+09 | 83186095.08 | 0.153057E+09 | 69334437.82 | 83722287.52 | 0.00 | 0.00 |
| May | 0.289785E+09 | 30264632.99 | 0.162693E+09 | 70596429.69 | 92097029.55 | 0.00 | 0.00 |
| June | 0.293449E+09 | 26796508.67 | 0.159596E+09 | 63316144.12 | 96279938.30 | 0.00 | 0.00 |
| July | 0.291237E+09 | 20810328.49 | 0.159117E+09 | 58310544.18 | 0.100806E+09 | 0.00 | 0.00 |
| August | 0.265229E+09 | 28313128.35 | 0.146555E+09 | 50345840.18 | 96209131.71 | 0.00 | 0.00 |
| September | 0.216643E+09 | 37767378.88 | 0.125443E+09 | 43046521.61 | 82396866.72 | 0.00 | 0.00 |
| October | 0.210789E+09 | 63188915.37 | 0.128553E+09 | 54398053.92 | 74154917.49 | 0.00 | 0.00 |
| November | 0.144142E+09 | 0.120846E+09 | 0.109897E+09 | 56038620.23 | 53858482.92 | 0.00 | 0.00 |
| December | 0.104291E+09 | 0.161437E+09 | 89477051.85 | 40583791.43 | 48893260.42 | 0.00 | 0.00 |
| Annual Sum or Average | 0.250244E+10 | 0.101037E+10 | 0.159849E+10 | 0.684513E+09 | 0.913979E+09 | 0.00 | 0.00 |
| Minimum of Months | 0.104291E+09 | 20810328.49 | 89477051.85 | 40583791.43 | 48893260.42 | 0.00 | 0.00 |
| Maximum of Months | 0.293449E+09 | 0.176430E+09 | 0.162693E+09 | 70596429.69 | 0.100806E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 40270961.46 | 65137084.14 | 37000590.41 | 18917749.03 | 18082841.38 | 0.00 | 0.00 |
| February | 42639164.32 | 50464594.48 | 36976834.69 | 17782644.90 | 19194189.79 | 0.00 | 0.00 |
| March | 61760290.36 | 47876509.84 | 48276830.86 | 23248405.00 | 25028425.86 | 0.00 | 0.00 |
| April | 75740706.46 | 29657414.60 | 51391516.41 | 23280270.05 | 28111246.36 | 0.00 | 0.00 |
| May | 99756410.80 | 8819721.68 | 54627221.13 | 23704006.26 | 30923214.88 | 0.00 | 0.00 |
| June | 0.101752E+09 | 7380667.88 | 53587221.80 | 21259520.96 | 32327700.85 | 0.00 | 0.00 |
| July | 0.101842E+09 | 5002224.09 | 53426268.34 | 19578801.79 | 33847466.55 | 0.00 | 0.00 |
| August | 93086392.14 | 7218295.84 | 49208437.11 | 16904510.83 | 32303926.28 | 0.00 | 0.00 |
| September | 75652279.46 | 10442574.86 | 42119847.63 | 14453634.87 | 27666212.77 | 0.00 | 0.00 |
| October | 72552654.73 | 19559990.76 | 43163945.43 | 18265113.63 | 24898831.79 | 0.00 | 0.00 |
| November | 47376197.92 | 42037990.85 | 36899906.01 | 18815962.94 | 18083943.08 | 0.00 | 0.00 |
| December | 33540028.42 | 58227960.89 | 30043510.79 | 13626729.43 | 16416781.36 | 0.00 | 0.00 |
| Annual Sum or Average | 0.845969E+09 | 0.351825E+09 | 0.536722E+09 | 0.229837E+09 | 0.306885E+09 | 0.00 | 0.00 |
| Minimum of Months | 33540028.42 | 5002224.09 | 30043510.79 | 13626729.43 | 16416781.36 | 0.00 | 0.00 |
| Maximum of Months | 0.101842E+09 | 65137084.14 | 54627221.13 | 23704006.26 | 33847466.55 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 13.57 | 11.02 | 8.64 | 3.24 | 3.13 | 48.31 | 209.17 | 0.01 |
| February | 15.49 | 12.82 | 10.40 | 2.82 | 4.36 | 58.07 | 218.23 | 0.02 |
| March | 17.07 | 13.58 | 10.72 | 3.68 | 7.24 | 76.61 | 186.08 | 0.03 |
| April | 21.23 | 17.54 | 15.23 | 2.65 | 11.47 | 90.28 | 216.86 | 0.02 |
| May | 26.90 | 22.82 | 21.10 | 3.11 | 19.64 | 106.10 | 173.47 | 0.04 |
| June | 27.61 | 23.37 | 21.62 | 2.44 | 19.77 | 115.40 | 187.69 | 0.03 |
| July | 27.94 | 24.58 | 23.34 | 2.53 | 20.70 | 123.49 | 154.05 | 0.05 |
| August | 27.43 | 23.90 | 22.52 | 3.20 | 20.40 | 118.51 | 145.78 | 0.03 |
| September | 26.23 | 23.37 | 22.24 | 3.39 | 19.02 | 101.73 | 135.58 | 0.05 |
| October | 24.23 | 20.47 | 18.40 | 4.11 | 16.60 | 78.24 | 178.15 | 0.01 |
| November | 18.91 | 15.31 | 12.62 | 2.63 | 7.99 | 49.56 | 205.43 | 0.01 |
| December | 15.68 | 12.88 | 10.53 | 3.17 | 6.01 | 45.08 | 191.18 | 0.02 |
| Annual Sum or Average | 21.89 | 18.50 | 16.48 | 3.09 | 13.08 | 84.44 | 183.16 | 0.03 |
| Minimum of Months | 13.57 | 11.02 | 8.64 | 2.44 | 3.13 | 45.08 | 135.58 | 0.01 |
| Maximum of Months | 27.94 | 24.58 | 23.34 | 4.11 | 20.70 | 123.49 | 218.23 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 27.00 | 02-JAN-14:00 | 18.67 | 14.00 | 1.50 | 17.75 | 146.50 | 0.00 |
| February | 28.30 | 02-FEB-12:00 | 20.78 | 17.20 | 6.60 | 17.93 | 127.50 | 748.50 |
| March | 30.00 | 26-MAR-13:00 | 19.88 | 14.40 | 3.00 | 19.52 | 288.50 | 548.00 |
| April | 33.30 | 28-APR-14:00 | 23.06 | 18.80 | 4.10 | 23.15 | 150.50 | 762.50 |
| May | 33.90 | 07-MAY-13:00 | 23.76 | 19.40 | 4.10 | 23.15 | 287.50 | 507.50 |
| June | 35.00 | 14-JUN-13:00 | 23.95 | 19.40 | 2.10 | 24.16 | 194.50 | 712.50 |
| July | 36.10 | 21-JUL-15:00 | 25.96 | 22.20 | 1.50 | 26.65 | 216.00 | 245.00 |
| August | 36.30 | 30-AUG-15:00 | 23.74 | 18.50 | 2.40 | 25.33 | 116.00 | 698.50 |
| September | 36.40 | 09-SEP-16:00 | 26.65 | 23.40 | 4.40 | 26.48 | 114.00 | 401.50 |
| October | 34.00 | 05-OCT-14:00 | 24.05 | 20.00 | 2.60 | 29.55 | 169.50 | 606.00 |
| November | 30.00 | 01-NOV-13:00 | 25.01 | 23.30 | 2.00 | 26.48 | 216.50 | 118.00 |
| December | 30.00 | 13-DEC-14:00 | 21.84 | 18.00 | 3.10 | 20.92 | 101.50 | 682.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 27.00 | 18.67 | 14.00 | 1.50 | 17.75 | 101.50 | 0.00 | |
| Maximum of Months | 36.40 | 26.65 | 23.40 | 6.60 | 29.55 | 288.50 | 762.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 0.00 | 05-JAN-05:00 | -0.0 | -0.0 | 2.10 | -16.0 | 0.00 | 0.00 |
| February | -3.4 | 05-FEB-07:10 | -5.4 | -9.4 | 4.68 | -21.3 | 0.00 | 0.00 |
| March | 1.10 | 09-MAR-05:00 | -2.1 | -7.3 | 3.60 | -14.4 | 0.00 | 0.00 |
| April | 8.30 | 11-APR-05:00 | 6.95 | 5.50 | 0.00 | -6.9 | 0.00 | 0.00 |
| May | 21.10 | 07-MAY-00:00 | 19.58 | 18.90 | 0.00 | 11.46 | 0.00 | 0.00 |
| June | 20.60 | 07-JUN-01:00 | 18.00 | 16.70 | 3.60 | 10.50 | 0.00 | 0.00 |
| July | 22.20 | 11-JUL-19:00 | 21.37 | 21.10 | 2.10 | 20.22 | 0.00 | 0.00 |
| August | 20.20 | 25-AUG-23:00 | 20.20 | 20.20 | 5.30 | 11.84 | 0.00 | 0.00 |
| September | 19.20 | 07-SEP-17:00 | 19.20 | 19.20 | 2.50 | 16.85 | 35.00 | 7.00 |
| October | 10.00 | 28-OCT-04:00 | 5.56 | 0.00 | 3.60 | -0.1 | 0.00 | 0.00 |
| November | 7.20 | 12-NOV-07:49 | 4.12 | 0.18 | 4.60 | -9.0 | 36.00 | 517.00 |
| December | 0.00 | 21-DEC-04:00 | -0.9 | -2.0 | 2.10 | -16.2 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -3.4 | -5.4 | -9.4 | 0.00 | -21.3 | 0.00 | 0.00 | |
| Maximum of Months | 22.20 | 21.37 | 21.10 | 5.30 | 20.22 | 36.00 | 517.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 22.11 | 31-JAN-12:00 | 25.00 | 21.00 | 5.70 | 20.92 | 336.50 | 96.00 |
| February | 21.49 | 24-FEB-12:00 | 27.70 | 18.80 | 4.10 | 17.75 | 165.00 | 746.50 |
| March | 22.77 | 30-MAR-12:00 | 29.40 | 20.00 | 2.50 | 27.14 | 340.00 | 0.00 |
| April | 25.55 | 28-APR-15:00 | 32.20 | 23.30 | 3.60 | 22.47 | 156.00 | 575.50 |
| May | 25.84 | 27-MAY-13:00 | 31.70 | 23.90 | 3.10 | 22.13 | 168.50 | 735.50 |
| June | 26.52 | 29-JUN-16:00 | 29.40 | 25.60 | 1.50 | 26.32 | 164.00 | 36.00 |
| July | 27.17 | 22-JUL-10:00 | 32.20 | 25.60 | 2.10 | 21.96 | 191.00 | 719.50 |
| August | 27.24 | 07-AUG-12:00 | 31.00 | 26.00 | 3.10 | 27.95 | 473.00 | 200.00 |
| September | 27.79 | 10-SEP-12:00 | 35.00 | 25.50 | 2.90 | 24.66 | 239.50 | 662.00 |
| October | 28.18 | 07-OCT-07:00 | 29.00 | 28.00 | 2.60 | 21.09 | 95.00 | 500.50 |
| November | 25.01 | 01-NOV-13:00 | 30.00 | 23.30 | 2.00 | 26.48 | 216.50 | 118.00 |
| December | 24.12 | 12-DEC-13:00 | 27.00 | 23.00 | 2.10 | 19.17 | 160.50 | 599.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 21.49 | 25.00 | 18.80 | 1.50 | 17.75 | 95.00 | 0.00 | |
| Maximum of Months | 28.18 | 35.00 | 28.00 | 5.70 | 27.95 | 473.00 | 746.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 21.00 | 31-JAN-12:00 | 25.00 | 22.11 | 5.70 | 20.92 | 336.50 | 96.00 |
| February | 20.20 | 02-FEB-22:00 | 21.50 | 20.56 | 4.80 | 14.65 | 0.00 | 0.00 |
| March | 21.10 | 07-MAR-08:00 | 23.30 | 21.69 | 2.00 | 13.91 | 126.00 | 566.50 |
| April | 23.30 | 28-APR-15:00 | 32.20 | 25.55 | 3.60 | 22.47 | 156.00 | 575.50 |
| May | 24.40 | 26-MAY-08:20 | 27.07 | 25.09 | 3.10 | 23.71 | 252.67 | 47.33 |
| June | 25.60 | 29-JUN-14:00 | 27.20 | 26.00 | 5.10 | 24.16 | 335.00 | 238.00 |
| July | 25.60 | 02-JUL-05:00 | 26.10 | 25.71 | 2.60 | 19.52 | 30.50 | 8.50 |
| August | 26.60 | 09-AUG-18:00 | 26.60 | 26.60 | 1.90 | 19.52 | 26.00 | 23.00 |
| September | 25.50 | 10-SEP-12:00 | 35.00 | 27.79 | 2.90 | 24.66 | 239.50 | 662.00 |
| October | 28.00 | 07-OCT-07:00 | 29.00 | 28.18 | 2.60 | 21.09 | 95.00 | 500.50 |
| November | 23.80 | 01-NOV-10:00 | 26.10 | 24.39 | 2.00 | 22.64 | 228.50 | 113.00 |
| December | 23.00 | 12-DEC-13:00 | 27.00 | 24.12 | 2.10 | 19.17 | 160.50 | 599.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 20.20 | 21.50 | 20.56 | 1.90 | 13.91 | 0.00 | 0.00 | |
| Maximum of Months | 28.00 | 35.00 | 28.18 | 5.70 | 24.66 | 336.50 | 662.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 20.46 | 29.60 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 20.78 | 36.65 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 22.23 | 38.94 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 24.49 | 49.11 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 26.95 | 46.95 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 28.93 | 51.71 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 29.89 | 48.43 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 29.58 | 45.50 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 28.08 | 39.22 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 25.80 | 37.51 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 23.35 | 31.26 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 21.40 | 27.18 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 25.18 | 40.17 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 20.46 | 27.18 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 29.89 | 51.71 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101440E+10 | -838197005.2 | 0.00 | 0.00 | 744.00 | 0.00 | -176204724.3 | 59.44 | 0.00 | 0.00 |
| February | 0.909787E+09 | -750833223.1 | 0.00 | 0.00 | 672.00 | 0.00 | -158954156.4 | 59.44 | 0.00 | 0.00 |
| March | 0.976183E+09 | -800122270.3 | 0.00 | 0.00 | 744.00 | 0.00 | -176060359.4 | 59.44 | 0.00 | 0.00 |
| April | 0.894471E+09 | -727173183.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167297604.7 | 59.44 | 0.00 | 0.00 |
| May | 0.871168E+09 | -698684920.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172482712.1 | 59.44 | 0.00 | 0.00 |
| June | 0.801866E+09 | -634940203.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166925578.5 | 59.44 | 0.00 | 0.00 |
| July | 0.807788E+09 | -635305977.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172481986.4 | 59.44 | 0.00 | 0.00 |
| August | 0.814525E+09 | -642037462.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172487292.9 | 59.44 | 0.00 | 0.00 |
| September | 0.819465E+09 | -652547490.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166917839.7 | 59.44 | 0.00 | 0.00 |
| October | 0.895917E+09 | -723406640.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172510168.0 | 59.44 | 0.00 | 0.00 |
| November | 0.918116E+09 | -751004120.5 | 0.00 | 0.00 | 720.00 | 0.00 | -167112113.4 | 59.44 | 0.00 | 0.00 |
| December | 0.992789E+09 | -818000233.8 | 0.00 | 0.00 | 744.00 | 0.00 | -174788393.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107165E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.204422E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801866E+09 | -838197005.2 | 0.00 | 0.00 | 672.00 | 0.00 | -176204724.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101440E+10 | -634940203.3 | 0.00 | 0.00 | 744.00 | 0.00 | -158954156.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101897E+10 | -838195742.1 | 0.00 | 0.00 | 744.00 | 0.00 | -180773370.7 | 59.44 | 0.00 | 0.00 |
| February | 0.912541E+09 | -750832410.2 | 0.00 | 0.00 | 672.00 | 0.00 | -161708563.0 | 59.44 | 0.00 | 0.00 |
| March | 0.977642E+09 | -800117923.4 | 0.00 | 0.00 | 744.00 | 0.00 | -177524388.1 | 59.44 | 0.00 | 0.00 |
| April | 0.894706E+09 | -727166104.4 | 0.00 | 0.00 | 720.00 | 0.00 | -167539793.9 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698680627.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172486748.7 | 59.44 | 0.00 | 0.00 |
| June | 0.801864E+09 | -634944497.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166919419.6 | 59.44 | 0.00 | 0.00 |
| July | 0.807790E+09 | -635309317.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172480548.5 | 59.44 | 0.00 | 0.00 |
| August | 0.814524E+09 | -642037342.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172486425.6 | 59.44 | 0.00 | 0.00 |
| September | 0.819467E+09 | -652546544.1 | 0.00 | 0.00 | 720.00 | 0.00 | -166920645.5 | 59.44 | 0.00 | 0.00 |
| October | 0.895985E+09 | -723406392.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172578387.7 | 59.44 | 0.00 | 0.00 |
| November | 0.918829E+09 | -751008581.2 | 0.00 | 0.00 | 720.00 | 0.00 | -167820099.8 | 59.44 | 0.00 | 0.00 |
| December | 0.995633E+09 | -817998263.1 | 0.00 | 0.00 | 744.00 | 0.00 | -177634375.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107291E+11 | -0.867224E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205687E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801864E+09 | -838195742.1 | 0.00 | 0.00 | 672.00 | 0.00 | -180773370.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101897E+10 | -634944497.9 | 0.00 | 0.00 | 744.00 | 0.00 | -161708563.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101898E+10 | -838195562.4 | 0.00 | 0.00 | 744.00 | 0.00 | -180780844.2 | 59.44 | 0.00 | 0.00 |
| February | 0.912536E+09 | -750832286.7 | 0.00 | 0.00 | 672.00 | 0.00 | -161703774.7 | 59.44 | 0.00 | 0.00 |
| March | 0.977572E+09 | -800117623.7 | 0.00 | 0.00 | 744.00 | 0.00 | -177454763.5 | 59.44 | 0.00 | 0.00 |
| April | 0.894667E+09 | -727163805.4 | 0.00 | 0.00 | 720.00 | 0.00 | -167503117.3 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698679732.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172487480.5 | 59.44 | 0.00 | 0.00 |
| June | 0.801862E+09 | -634945772.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166916621.1 | 59.44 | 0.00 | 0.00 |
| July | 0.807792E+09 | -635308116.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172483451.1 | 59.44 | 0.00 | 0.00 |
| August | 0.814522E+09 | -642039881.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172482253.6 | 59.44 | 0.00 | 0.00 |
| September | 0.819469E+09 | -652545598.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166922938.0 | 59.44 | 0.00 | 0.00 |
| October | 0.895982E+09 | -723405306.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172576720.6 | 59.44 | 0.00 | 0.00 |
| November | 0.918744E+09 | -751004195.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167740229.8 | 59.44 | 0.00 | 0.00 |
| December | 0.995772E+09 | -818001303.9 | 0.00 | 0.00 | 744.00 | 0.00 | -177770799.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107291E+11 | -0.867224E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205682E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801862E+09 | -838195562.4 | 0.00 | 0.00 | 672.00 | 0.00 | -180780844.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101898E+10 | -634945772.3 | 0.00 | 0.00 | 744.00 | 0.00 | -161703774.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101800E+10 | -838196933.4 | 0.00 | 0.00 | 744.00 | 0.00 | -179802478.2 | 59.44 | 0.00 | 0.00 |
| February | 0.911789E+09 | -750836172.8 | 0.00 | 0.00 | 672.00 | 0.00 | -160952709.4 | 59.44 | 0.00 | 0.00 |
| March | 0.976669E+09 | -800118577.7 | 0.00 | 0.00 | 744.00 | 0.00 | -176550424.4 | 59.44 | 0.00 | 0.00 |
| April | 0.894367E+09 | -727160519.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167206796.8 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698679020.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172488180.0 | 59.44 | 0.00 | 0.00 |
| June | 0.801864E+09 | -634950445.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166913779.1 | 59.44 | 0.00 | 0.00 |
| July | 0.807792E+09 | -635306761.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172485269.9 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642043836.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172479290.2 | 59.44 | 0.00 | 0.00 |
| September | 0.819468E+09 | -652547636.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166920136.6 | 59.44 | 0.00 | 0.00 |
| October | 0.895928E+09 | -723401540.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172526315.2 | 59.44 | 0.00 | 0.00 |
| November | 0.918386E+09 | -751006089.0 | 0.00 | 0.00 | 720.00 | 0.00 | -167380366.4 | 59.44 | 0.00 | 0.00 |
| December | 0.994619E+09 | -817998050.9 | 0.00 | 0.00 | 744.00 | 0.00 | -176620996.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107246E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205233E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801864E+09 | -838196933.4 | 0.00 | 0.00 | 672.00 | 0.00 | -179802478.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101800E+10 | -634950445.7 | 0.00 | 0.00 | 744.00 | 0.00 | -160952709.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101800E+10 | -838196881.1 | 0.00 | 0.00 | 744.00 | 0.00 | -179801394.1 | 59.44 | 0.00 | 0.00 |
| February | 0.911784E+09 | -750835977.1 | 0.00 | 0.00 | 672.00 | 0.00 | -160948061.3 | 59.44 | 0.00 | 0.00 |
| March | 0.976660E+09 | -800118466.3 | 0.00 | 0.00 | 744.00 | 0.00 | -176541305.7 | 59.44 | 0.00 | 0.00 |
| April | 0.894365E+09 | -727160635.6 | 0.00 | 0.00 | 720.00 | 0.00 | -167204793.5 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698679003.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172488185.8 | 59.44 | 0.00 | 0.00 |
| June | 0.801864E+09 | -634950459.0 | 0.00 | 0.00 | 720.00 | 0.00 | -166913779.1 | 59.44 | 0.00 | 0.00 |
| July | 0.807792E+09 | -635306758.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172485269.4 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642043832.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172479293.2 | 59.44 | 0.00 | 0.00 |
| September | 0.819468E+09 | -652547645.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920125.0 | 59.44 | 0.00 | 0.00 |
| October | 0.895928E+09 | -723401540.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172526403.1 | 59.44 | 0.00 | 0.00 |
| November | 0.918382E+09 | -751006295.4 | 0.00 | 0.00 | 720.00 | 0.00 | -167375929.9 | 59.44 | 0.00 | 0.00 |
| December | 0.994638E+09 | -817998042.7 | 0.00 | 0.00 | 744.00 | 0.00 | -176640103.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107246E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205232E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801864E+09 | -838196881.1 | 0.00 | 0.00 | 672.00 | 0.00 | -179801394.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101800E+10 | -634950459.0 | 0.00 | 0.00 | 744.00 | 0.00 | -160948061.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101257E+10 | -838199693.1 | 0.00 | 0.00 | 744.00 | 0.00 | -174368254.4 | 59.44 | 0.00 | 0.00 |
| February | 0.908448E+09 | -750840066.1 | 0.00 | 0.00 | 672.00 | 0.00 | -157608328.1 | 59.44 | 0.00 | 0.00 |
| March | 0.974968E+09 | -800112108.4 | 0.00 | 0.00 | 744.00 | 0.00 | -174855910.3 | 59.44 | 0.00 | 0.00 |
| April | 0.894213E+09 | -727172783.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167040057.9 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698680632.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172486674.5 | 59.44 | 0.00 | 0.00 |
| June | 0.801864E+09 | -634944986.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166919443.3 | 59.44 | 0.00 | 0.00 |
| July | 0.807789E+09 | -635308359.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172480575.6 | 59.44 | 0.00 | 0.00 |
| August | 0.814524E+09 | -642037444.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172486859.5 | 59.44 | 0.00 | 0.00 |
| September | 0.819467E+09 | -652546678.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166920225.2 | 59.44 | 0.00 | 0.00 |
| October | 0.895892E+09 | -723406289.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172486164.2 | 59.44 | 0.00 | 0.00 |
| November | 0.917959E+09 | -751008695.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166949874.5 | 59.44 | 0.00 | 0.00 |
| December | 0.991616E+09 | -817995417.5 | 0.00 | 0.00 | 744.00 | 0.00 | -173620877.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107105E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203822E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801864E+09 | -838199693.1 | 0.00 | 0.00 | 672.00 | 0.00 | -174855910.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101257E+10 | -634944986.8 | 0.00 | 0.00 | 744.00 | 0.00 | -157608328.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101242E+10 | -838195605.0 | 0.00 | 0.00 | 744.00 | 0.00 | -174220457.5 | 59.44 | 0.00 | 0.00 |
| February | 0.908345E+09 | -750838898.8 | 0.00 | 0.00 | 672.00 | 0.00 | -157506294.5 | 59.44 | 0.00 | 0.00 |
| March | 0.974803E+09 | -800123574.5 | 0.00 | 0.00 | 744.00 | 0.00 | -174679440.7 | 59.44 | 0.00 | 0.00 |
| April | 0.894177E+09 | -727158509.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167018219.4 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698679075.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172488150.0 | 59.44 | 0.00 | 0.00 |
| June | 0.801864E+09 | -634950401.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166913783.2 | 59.44 | 0.00 | 0.00 |
| July | 0.807792E+09 | -635306781.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172485272.4 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642043867.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172479268.5 | 59.44 | 0.00 | 0.00 |
| September | 0.819468E+09 | -652547542.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166920223.1 | 59.44 | 0.00 | 0.00 |
| October | 0.895889E+09 | -723401707.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172487443.3 | 59.44 | 0.00 | 0.00 |
| November | 0.917943E+09 | -751001464.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166941753.7 | 59.44 | 0.00 | 0.00 |
| December | 0.991492E+09 | -818001476.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173490994.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107099E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203763E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801864E+09 | -838195605.0 | 0.00 | 0.00 | 672.00 | 0.00 | -174679440.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101242E+10 | -634950401.3 | 0.00 | 0.00 | 744.00 | 0.00 | -157506294.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185285E+10 | -0.167640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176453829.6 | 59.44 | 0.00 | 0.00 |
| February | 0.165990E+10 | -0.150167E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -158224574.0 | 59.44 | 0.00 | 0.00 |
| March | 0.177538E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175144339.2 | 59.44 | 0.00 | 0.00 |
| April | 0.162139E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167043690.6 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486736.2 | 59.44 | 0.00 | 0.00 |
| June | 0.143681E+10 | -0.126989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919486.4 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483358.3 | 59.44 | 0.00 | 0.00 |
| August | 0.145657E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485009.2 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130509E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920274.7 | 59.44 | 0.00 | 0.00 |
| October | 0.161941E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172591301.8 | 59.44 | 0.00 | 0.00 |
| November | 0.166936E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167346082.7 | 59.44 | 0.00 | 0.00 |
| December | 0.181140E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175399833.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193880E+11 | -0.173445E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.204350E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143681E+10 | -0.167640E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -176453829.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185285E+10 | -0.126989E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -158224574.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185719E+10 | -0.167640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180792893.2 | 59.44 | 0.00 | 0.00 |
| February | 0.166215E+10 | -0.150168E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -160466414.2 | 59.44 | 0.00 | 0.00 |
| March | 0.177646E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176221034.3 | 59.44 | 0.00 | 0.00 |
| April | 0.162147E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167131514.2 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486685.3 | 59.44 | 0.00 | 0.00 |
| June | 0.143681E+10 | -0.126989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919510.1 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483360.7 | 59.44 | 0.00 | 0.00 |
| August | 0.145657E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485012.7 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130509E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920277.6 | 59.44 | 0.00 | 0.00 |
| October | 0.161955E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172738039.5 | 59.44 | 0.00 | 0.00 |
| November | 0.167032E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168300472.5 | 59.44 | 0.00 | 0.00 |
| December | 0.181424E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178241227.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193997E+11 | -0.173445E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205519E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143681E+10 | -0.167640E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -180792893.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185719E+10 | -0.126989E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -160466414.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185272E+10 | -0.167640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176324113.3 | 59.44 | 0.00 | 0.00 |
| February | 0.165985E+10 | -0.150168E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -158169037.8 | 59.44 | 0.00 | 0.00 |
| March | 0.177528E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175038005.5 | 59.44 | 0.00 | 0.00 |
| April | 0.162137E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167028791.7 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172487173.1 | 59.44 | 0.00 | 0.00 |
| June | 0.143681E+10 | -0.126989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919468.7 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483369.1 | 59.44 | 0.00 | 0.00 |
| August | 0.145657E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485017.8 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130509E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920283.2 | 59.44 | 0.00 | 0.00 |
| October | 0.161941E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172590798.5 | 59.44 | 0.00 | 0.00 |
| November | 0.166934E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167318985.0 | 59.44 | 0.00 | 0.00 |
| December | 0.181143E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175426370.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193877E+11 | -0.173445E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.204319E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143681E+10 | -0.167640E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -176324113.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185272E+10 | -0.126989E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -158169037.8 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185723E+10 | -0.167640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180831396.5 | 59.44 | 0.00 | 0.00 |
| February | 0.166211E+10 | -0.150167E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -160440509.3 | 59.44 | 0.00 | 0.00 |
| March | 0.177635E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176107120.4 | 59.44 | 0.00 | 0.00 |
| April | 0.162144E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167095545.8 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486750.4 | 59.44 | 0.00 | 0.00 |
| June | 0.143681E+10 | -0.126989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919497.6 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483370.2 | 59.44 | 0.00 | 0.00 |
| August | 0.145657E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485020.2 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130509E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920284.9 | 59.44 | 0.00 | 0.00 |
| October | 0.161955E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172733658.4 | 59.44 | 0.00 | 0.00 |
| November | 0.167021E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168194830.3 | 59.44 | 0.00 | 0.00 |
| December | 0.181439E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -178390677.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193996E+11 | -0.173445E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205509E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143681E+10 | -0.167640E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -180831396.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185723E+10 | -0.126989E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -160440509.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185611E+10 | -0.167639E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179711420.0 | 59.44 | 0.00 | 0.00 |
| February | 0.166129E+10 | -0.150168E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -159607969.2 | 59.44 | 0.00 | 0.00 |
| March | 0.177558E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175336777.7 | 59.44 | 0.00 | 0.00 |
| April | 0.162132E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166981367.3 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486732.1 | 59.44 | 0.00 | 0.00 |
| June | 0.143681E+10 | -0.126989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919498.7 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483373.1 | 59.44 | 0.00 | 0.00 |
| August | 0.145657E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485022.8 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130509E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920288.6 | 59.44 | 0.00 | 0.00 |
| October | 0.161941E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172591981.4 | 59.44 | 0.00 | 0.00 |
| November | 0.166959E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167571819.1 | 59.44 | 0.00 | 0.00 |
| December | 0.181296E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176951621.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193946E+11 | -0.173445E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205005E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143681E+10 | -0.167639E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -179711420.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185611E+10 | -0.126989E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -159607969.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185611E+10 | -0.167639E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -179713829.9 | 59.44 | 0.00 | 0.00 |
| February | 0.166128E+10 | -0.150168E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -159601748.0 | 59.44 | 0.00 | 0.00 |
| March | 0.177556E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175323787.0 | 59.44 | 0.00 | 0.00 |
| April | 0.162132E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166980440.3 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172486730.9 | 59.44 | 0.00 | 0.00 |
| June | 0.143681E+10 | -0.126989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166919498.6 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172483373.2 | 59.44 | 0.00 | 0.00 |
| August | 0.145657E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172485022.9 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130509E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920288.7 | 59.44 | 0.00 | 0.00 |
| October | 0.161941E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172592027.8 | 59.44 | 0.00 | 0.00 |
| November | 0.166958E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167566120.4 | 59.44 | 0.00 | 0.00 |
| December | 0.181298E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176973481.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193946E+11 | -0.173445E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205005E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143681E+10 | -0.167639E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -179713829.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185611E+10 | -0.126989E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -159601748.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185078E+10 | -0.167640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174380095.8 | 59.44 | 0.00 | 0.00 |
| February | 0.165878E+10 | -0.150168E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -157104772.6 | 59.44 | 0.00 | 0.00 |
| March | 0.177437E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174124962.3 | 59.44 | 0.00 | 0.00 |
| April | 0.162128E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166933814.8 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481529.8 | 59.44 | 0.00 | 0.00 |
| June | 0.143682E+10 | -0.126990E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920578.7 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482213.5 | 59.44 | 0.00 | 0.00 |
| August | 0.145656E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482560.5 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130510E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166921958.7 | 59.44 | 0.00 | 0.00 |
| October | 0.161932E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172511349.3 | 59.44 | 0.00 | 0.00 |
| November | 0.166904E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167026380.9 | 59.44 | 0.00 | 0.00 |
| December | 0.181000E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -173994444.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193819E+11 | -0.173446E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203736E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143682E+10 | -0.167640E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -174380095.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185078E+10 | -0.126990E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -157104772.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.185077E+10 | -0.167640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174376051.9 | 59.44 | 0.00 | 0.00 |
| February | 0.165878E+10 | -0.150168E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -157104014.1 | 59.44 | 0.00 | 0.00 |
| March | 0.177436E+10 | -0.160024E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174118569.3 | 59.44 | 0.00 | 0.00 |
| April | 0.162128E+10 | -0.145434E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166933735.3 | 59.44 | 0.00 | 0.00 |
| May | 0.156985E+10 | -0.139737E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172481531.4 | 59.44 | 0.00 | 0.00 |
| June | 0.143682E+10 | -0.126990E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166920577.0 | 59.44 | 0.00 | 0.00 |
| July | 0.144310E+10 | -0.127062E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482213.8 | 59.44 | 0.00 | 0.00 |
| August | 0.145656E+10 | -0.128408E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172482560.6 | 59.44 | 0.00 | 0.00 |
| September | 0.147202E+10 | -0.130510E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -166921958.8 | 59.44 | 0.00 | 0.00 |
| October | 0.161932E+10 | -0.144681E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172511597.9 | 59.44 | 0.00 | 0.00 |
| November | 0.166904E+10 | -0.150202E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167026578.2 | 59.44 | 0.00 | 0.00 |
| December | 0.181001E+10 | -0.163600E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174000949.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193819E+11 | -0.173446E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.203736E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.143682E+10 | -0.167640E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -174376051.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.185077E+10 | -0.126990E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -157104014.1 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101777E+10 | -838197603.2 | 0.00 | 0.00 | 744.00 | 0.00 | -179573302.4 | 59.44 | 0.00 | 0.00 |
| February | 0.911556E+09 | -750839122.6 | 0.00 | 0.00 | 672.00 | 0.00 | -160717018.7 | 59.44 | 0.00 | 0.00 |
| March | 0.977864E+09 | -800116446.2 | 0.00 | 0.00 | 744.00 | 0.00 | -177747405.9 | 59.44 | 0.00 | 0.00 |
| April | 0.895416E+09 | -727161226.0 | 0.00 | 0.00 | 720.00 | 0.00 | -168255121.8 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698679024.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172487995.1 | 59.44 | 0.00 | 0.00 |
| June | 0.801862E+09 | -634948983.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166913286.6 | 59.44 | 0.00 | 0.00 |
| July | 0.807793E+09 | -635307537.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172484999.2 | 59.44 | 0.00 | 0.00 |
| August | 0.814521E+09 | -642042476.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172478948.1 | 59.44 | 0.00 | 0.00 |
| September | 0.819469E+09 | -652543632.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166925854.9 | 59.44 | 0.00 | 0.00 |
| October | 0.896707E+09 | -723404775.7 | 0.00 | 0.00 | 744.00 | 0.00 | -173302244.5 | 59.44 | 0.00 | 0.00 |
| November | 0.920806E+09 | -750996137.5 | 0.00 | 0.00 | 720.00 | 0.00 | -169809782.8 | 59.44 | 0.00 | 0.00 |
| December | 0.996406E+09 | -817998788.7 | 0.00 | 0.00 | 744.00 | 0.00 | -178407601.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107313E+11 | -0.867224E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205910E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801862E+09 | -838197603.2 | 0.00 | 0.00 | 672.00 | 0.00 | -179573302.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101777E+10 | -634948983.9 | 0.00 | 0.00 | 744.00 | 0.00 | -160717018.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.102024E+10 | -838203568.8 | 0.00 | 0.00 | 744.00 | 0.00 | -182040660.0 | 59.44 | 0.00 | 0.00 |
| February | 0.913157E+09 | -750832215.4 | 0.00 | 0.00 | 672.00 | 0.00 | -162324751.0 | 59.44 | 0.00 | 0.00 |
| March | 0.978737E+09 | -800118049.3 | 0.00 | 0.00 | 744.00 | 0.00 | -178619364.2 | 59.44 | 0.00 | 0.00 |
| April | 0.895628E+09 | -727172830.2 | 0.00 | 0.00 | 720.00 | 0.00 | -168455439.9 | 59.44 | 0.00 | 0.00 |
| May | 0.871168E+09 | -698686661.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172481674.5 | 59.44 | 0.00 | 0.00 |
| June | 0.801866E+09 | -634950303.2 | 0.00 | 0.00 | 720.00 | 0.00 | -166915944.6 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635307986.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172482970.8 | 59.44 | 0.00 | 0.00 |
| August | 0.814524E+09 | -642041476.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172482034.7 | 59.44 | 0.00 | 0.00 |
| September | 0.819466E+09 | -652547070.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166919045.9 | 59.44 | 0.00 | 0.00 |
| October | 0.896992E+09 | -723398172.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173593844.5 | 59.44 | 0.00 | 0.00 |
| November | 0.922327E+09 | -751004888.4 | 0.00 | 0.00 | 720.00 | 0.00 | -171321678.9 | 59.44 | 0.00 | 0.00 |
| December | 0.998355E+09 | -817999560.4 | 0.00 | 0.00 | 744.00 | 0.00 | -180355873.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107403E+11 | -0.867226E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.206799E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801866E+09 | -838203568.8 | 0.00 | 0.00 | 672.00 | 0.00 | -182040660.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.102024E+10 | -634950303.2 | 0.00 | 0.00 | 744.00 | 0.00 | -162324751.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101768E+10 | -838198308.2 | 0.00 | 0.00 | 744.00 | 0.00 | -179482339.9 | 59.44 | 0.00 | 0.00 |
| February | 0.911507E+09 | -750840276.9 | 0.00 | 0.00 | 672.00 | 0.00 | -160666226.3 | 59.44 | 0.00 | 0.00 |
| March | 0.977721E+09 | -800117262.2 | 0.00 | 0.00 | 744.00 | 0.00 | -177604078.6 | 59.44 | 0.00 | 0.00 |
| April | 0.895339E+09 | -727162241.8 | 0.00 | 0.00 | 720.00 | 0.00 | -168177079.3 | 59.44 | 0.00 | 0.00 |
| May | 0.871168E+09 | -698684010.4 | 0.00 | 0.00 | 744.00 | 0.00 | -172483816.6 | 59.44 | 0.00 | 0.00 |
| June | 0.801866E+09 | -634950971.4 | 0.00 | 0.00 | 720.00 | 0.00 | -166914664.2 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635308635.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172482849.8 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642041461.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172481919.6 | 59.44 | 0.00 | 0.00 |
| September | 0.819466E+09 | -652547162.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166919103.9 | 59.44 | 0.00 | 0.00 |
| October | 0.896694E+09 | -723398719.3 | 0.00 | 0.00 | 744.00 | 0.00 | -173295182.8 | 59.44 | 0.00 | 0.00 |
| November | 0.920694E+09 | -751000973.4 | 0.00 | 0.00 | 720.00 | 0.00 | -169693141.0 | 59.44 | 0.00 | 0.00 |
| December | 0.996402E+09 | -818002057.4 | 0.00 | 0.00 | 744.00 | 0.00 | -178399682.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107309E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205860E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801866E+09 | -838198308.2 | 0.00 | 0.00 | 672.00 | 0.00 | -179482339.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101768E+10 | -634950971.4 | 0.00 | 0.00 | 744.00 | 0.00 | -160666226.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.102035E+10 | -838199547.1 | 0.00 | 0.00 | 744.00 | 0.00 | -182149659.2 | 59.44 | 0.00 | 0.00 |
| February | 0.913198E+09 | -750839656.9 | 0.00 | 0.00 | 672.00 | 0.00 | -162358431.6 | 59.44 | 0.00 | 0.00 |
| March | 0.978642E+09 | -800123296.9 | 0.00 | 0.00 | 744.00 | 0.00 | -178518689.4 | 59.44 | 0.00 | 0.00 |
| April | 0.895540E+09 | -727163094.5 | 0.00 | 0.00 | 720.00 | 0.00 | -168377148.5 | 59.44 | 0.00 | 0.00 |
| May | 0.871168E+09 | -698682569.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172485092.6 | 59.44 | 0.00 | 0.00 |
| June | 0.801865E+09 | -634950830.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166914478.5 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635308268.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172483073.7 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642043245.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172479881.7 | 59.44 | 0.00 | 0.00 |
| September | 0.819468E+09 | -652547966.3 | 0.00 | 0.00 | 720.00 | 0.00 | -166919590.2 | 59.44 | 0.00 | 0.00 |
| October | 0.897021E+09 | -723400035.5 | 0.00 | 0.00 | 744.00 | 0.00 | -173621245.2 | 59.44 | 0.00 | 0.00 |
| November | 0.922292E+09 | -751004306.4 | 0.00 | 0.00 | 720.00 | 0.00 | -171287990.3 | 59.44 | 0.00 | 0.00 |
| December | 0.998500E+09 | -818001196.2 | 0.00 | 0.00 | 744.00 | 0.00 | -180499284.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107404E+11 | -0.867226E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.206809E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801865E+09 | -838199547.1 | 0.00 | 0.00 | 672.00 | 0.00 | -182149659.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.102035E+10 | -634950830.7 | 0.00 | 0.00 | 744.00 | 0.00 | -162358431.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.102001E+10 | -838197312.9 | 0.00 | 0.00 | 744.00 | 0.00 | -181814359.9 | 59.44 | 0.00 | 0.00 |
| February | 0.912750E+09 | -750837977.4 | 0.00 | 0.00 | 672.00 | 0.00 | -161912416.0 | 59.44 | 0.00 | 0.00 |
| March | 0.978238E+09 | -800120915.5 | 0.00 | 0.00 | 744.00 | 0.00 | -178117047.0 | 59.44 | 0.00 | 0.00 |
| April | 0.895200E+09 | -727167500.0 | 0.00 | 0.00 | 720.00 | 0.00 | -168032103.5 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698678905.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172488013.2 | 59.44 | 0.00 | 0.00 |
| June | 0.801865E+09 | -634950675.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166914231.6 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635306658.9 | 0.00 | 0.00 | 744.00 | 0.00 | -172484696.0 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642043500.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172479569.0 | 59.44 | 0.00 | 0.00 |
| September | 0.819468E+09 | -652547877.7 | 0.00 | 0.00 | 720.00 | 0.00 | -166919860.7 | 59.44 | 0.00 | 0.00 |
| October | 0.896788E+09 | -723399217.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173388963.8 | 59.44 | 0.00 | 0.00 |
| November | 0.921812E+09 | -750999739.3 | 0.00 | 0.00 | 720.00 | 0.00 | -170812516.4 | 59.44 | 0.00 | 0.00 |
| December | 0.998065E+09 | -817999053.9 | 0.00 | 0.00 | 744.00 | 0.00 | -180065691.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107377E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.206543E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801865E+09 | -838197312.9 | 0.00 | 0.00 | 672.00 | 0.00 | -181814359.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.102001E+10 | -634950675.9 | 0.00 | 0.00 | 744.00 | 0.00 | -161912416.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.102002E+10 | -838197376.9 | 0.00 | 0.00 | 744.00 | 0.00 | -181819892.6 | 59.44 | 0.00 | 0.00 |
| February | 0.912755E+09 | -750837788.8 | 0.00 | 0.00 | 672.00 | 0.00 | -161917396.6 | 59.44 | 0.00 | 0.00 |
| March | 0.978232E+09 | -800120503.7 | 0.00 | 0.00 | 744.00 | 0.00 | -178111283.1 | 59.44 | 0.00 | 0.00 |
| April | 0.895198E+09 | -727166656.3 | 0.00 | 0.00 | 720.00 | 0.00 | -168031742.7 | 59.44 | 0.00 | 0.00 |
| May | 0.871167E+09 | -698681858.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172485569.3 | 59.44 | 0.00 | 0.00 |
| June | 0.801865E+09 | -634950785.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166914493.1 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635308081.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172483245.2 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642043259.2 | 0.00 | 0.00 | 744.00 | 0.00 | -172479864.6 | 59.44 | 0.00 | 0.00 |
| September | 0.819468E+09 | -652547954.9 | 0.00 | 0.00 | 720.00 | 0.00 | -166919601.5 | 59.44 | 0.00 | 0.00 |
| October | 0.896794E+09 | -723399098.4 | 0.00 | 0.00 | 744.00 | 0.00 | -173394839.0 | 59.44 | 0.00 | 0.00 |
| November | 0.921813E+09 | -750999826.7 | 0.00 | 0.00 | 720.00 | 0.00 | -170813317.8 | 59.44 | 0.00 | 0.00 |
| December | 0.998079E+09 | -817998949.2 | 0.00 | 0.00 | 744.00 | 0.00 | -180080342.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107377E+11 | -0.867225E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.206545E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801865E+09 | -838197376.9 | 0.00 | 0.00 | 672.00 | 0.00 | -181819892.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.102002E+10 | -634950785.6 | 0.00 | 0.00 | 744.00 | 0.00 | -161917396.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101676E+10 | -838196154.9 | 0.00 | 0.00 | 744.00 | 0.00 | -178563776.8 | 59.44 | 0.00 | 0.00 |
| February | 0.910685E+09 | -750835754.0 | 0.00 | 0.00 | 672.00 | 0.00 | -159849502.7 | 59.44 | 0.00 | 0.00 |
| March | 0.977094E+09 | -800123597.1 | 0.00 | 0.00 | 744.00 | 0.00 | -176970690.9 | 59.44 | 0.00 | 0.00 |
| April | 0.894964E+09 | -727166408.1 | 0.00 | 0.00 | 720.00 | 0.00 | -167797741.4 | 59.44 | 0.00 | 0.00 |
| May | 0.871168E+09 | -698686505.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172481775.5 | 59.44 | 0.00 | 0.00 |
| June | 0.801866E+09 | -634950536.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166915490.7 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635308036.7 | 0.00 | 0.00 | 744.00 | 0.00 | -172482958.3 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642041227.5 | 0.00 | 0.00 | 744.00 | 0.00 | -172482168.9 | 59.44 | 0.00 | 0.00 |
| September | 0.819466E+09 | -652547066.6 | 0.00 | 0.00 | 720.00 | 0.00 | -166919068.3 | 59.44 | 0.00 | 0.00 |
| October | 0.896439E+09 | -723399528.2 | 0.00 | 0.00 | 744.00 | 0.00 | -173039946.0 | 59.44 | 0.00 | 0.00 |
| November | 0.919993E+09 | -751008428.8 | 0.00 | 0.00 | 720.00 | 0.00 | -168984683.9 | 59.44 | 0.00 | 0.00 |
| December | 0.995561E+09 | -817998708.0 | 0.00 | 0.00 | 744.00 | 0.00 | -177562676.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107263E+11 | -0.867226E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205405E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801866E+09 | -838196154.9 | 0.00 | 0.00 | 672.00 | 0.00 | -178563776.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101676E+10 | -634950536.5 | 0.00 | 0.00 | 744.00 | 0.00 | -159849502.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.101676E+10 | -838196171.2 | 0.00 | 0.00 | 744.00 | 0.00 | -178562375.9 | 59.44 | 0.00 | 0.00 |
| February | 0.910688E+09 | -750835762.8 | 0.00 | 0.00 | 672.00 | 0.00 | -159852494.0 | 59.44 | 0.00 | 0.00 |
| March | 0.977090E+09 | -800123558.7 | 0.00 | 0.00 | 744.00 | 0.00 | -176966447.5 | 59.44 | 0.00 | 0.00 |
| April | 0.894965E+09 | -727166323.5 | 0.00 | 0.00 | 720.00 | 0.00 | -167798655.2 | 59.44 | 0.00 | 0.00 |
| May | 0.871168E+09 | -698686516.6 | 0.00 | 0.00 | 744.00 | 0.00 | -172481769.6 | 59.44 | 0.00 | 0.00 |
| June | 0.801866E+09 | -634950537.8 | 0.00 | 0.00 | 720.00 | 0.00 | -166915494.5 | 59.44 | 0.00 | 0.00 |
| July | 0.807791E+09 | -635308037.3 | 0.00 | 0.00 | 744.00 | 0.00 | -172482959.4 | 59.44 | 0.00 | 0.00 |
| August | 0.814523E+09 | -642041229.8 | 0.00 | 0.00 | 744.00 | 0.00 | -172482168.7 | 59.44 | 0.00 | 0.00 |
| September | 0.819466E+09 | -652547066.5 | 0.00 | 0.00 | 720.00 | 0.00 | -166919068.3 | 59.44 | 0.00 | 0.00 |
| October | 0.896441E+09 | -723399507.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173041607.7 | 59.44 | 0.00 | 0.00 |
| November | 0.919994E+09 | -751008376.1 | 0.00 | 0.00 | 720.00 | 0.00 | -168985659.2 | 59.44 | 0.00 | 0.00 |
| December | 0.995568E+09 | -817998456.2 | 0.00 | 0.00 | 744.00 | 0.00 | -177569313.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107263E+11 | -0.867226E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.205406E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.801866E+09 | -838196171.2 | 0.00 | 0.00 | 672.00 | 0.00 | -178562375.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.101676E+10 | -634950537.8 | 0.00 | 0.00 | 744.00 | 0.00 | -159852494.0 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 307.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 295.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 296.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 347.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 353.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 394.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 390.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 380.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 342.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 330.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 308.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 282.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4027.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 282.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 394.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 3521663.61 | 228.11 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 36132292.46 | 939.05 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 48164986.98 | 588.68 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5701732.49 | 357.63 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 93520675.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 48164986.98 | 939.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.153414E+09 | 831.22 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.152834E+09 | 1253.90 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 96083133.94 | 695.16 | 11-MAR-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 59336762.97 | 776.69 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.461669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.153414E+09 | 1253.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.150032E+09 | 833.34 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.147542E+09 | 1177.07 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 89630486.10 | 689.69 | 11-MAR-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 62872151.34 | 805.24 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.450076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.150032E+09 | 1177.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 31549648.07 | 477.93 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 43599804.71 | 584.85 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 21585108.79 | 306.92 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 7520594.27 | 342.25 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.104255E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 43599804.71 | 584.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 31359568.95 | 476.55 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 43555184.22 | 585.07 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 21363569.54 | 306.13 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 7665940.12 | 344.44 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.103944E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 43555184.22 | 585.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1227723.49 | 189.86 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 1787018.33 | 167.04 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 3014741.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1787018.33 | 189.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 1134072.14 | 185.33 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 1351522.16 | 153.11 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 2485594.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1351522.16 | 185.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 30114220.54 | 943.38 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 90779352.77 | 2557.69 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 78459196.85 | 1227.38 | 11-MAR-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 66387868.92 | 1589.67 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.265741E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 90779352.77 | 2557.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.469250E+09 | 1979.59 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.296339E+09 | 3082.73 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.154149E+09 | 1492.60 | 11-MAR-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.264046E+09 | 2139.68 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.118378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.469250E+09 | 3082.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 27373709.49 | 933.79 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 85948077.42 | 2581.76 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 75129523.41 | 1216.75 | 11-MAR-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 69294007.36 | 1667.97 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.257745E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 85948077.42 | 2581.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.451719E+09 | 1994.71 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.285371E+09 | 2990.20 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.143719E+09 | 1486.10 | 11-MAR-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.272610E+09 | 2180.06 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.115342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.451719E+09 | 2990.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 92708957.77 | 1114.01 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81577981.73 | 1523.99 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 18692238.76 | 473.50 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 58336891.36 | 1261.35 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.251316E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 92708957.77 | 1523.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 92574870.61 | 1112.86 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81475851.85 | 1521.77 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 18440822.54 | 472.49 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 58925745.60 | 1264.45 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.251417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 92574870.61 | 1521.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 8700438.79 | 796.89 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 984968.49 | 199.40 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 500502.05 | 190.11 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 10185909.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 8700438.79 | 796.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 8686864.48 | 797.45 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 960868.78 | 197.75 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 554729.23 | 197.56 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 10202462.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 8686864.48 | 797.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.670467E+09 | 1932.33 | 21-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.436597E+09 | 2912.53 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.382379E+09 | 1876.78 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1536175.44 | 218.21 | 11-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 6354980.16 | 405.74 | 28-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 66979435.47 | 717.54 | 16-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.500709E+09 | 2081.48 | 20-DEC-07:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.206502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.670467E+09 | 2912.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.108382E+10 | 2087.79 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.654938E+09 | 3063.79 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.471458E+09 | 2029.98 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 5471959.30 | 345.05 | 03-APR-05:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 15905058.16 | 595.67 | 28-OCT-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.145851E+09 | 929.98 | 16-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.762140E+09 | 2176.81 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.313959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.108382E+10 | 3063.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.655371E+09 | 1954.53 | 21-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.425378E+09 | 2926.31 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.373458E+09 | 1897.29 | 09-MAR-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1400861.81 | 251.14 | 11-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 5855505.56 | 422.83 | 28-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63279858.78 | 732.38 | 16-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.500960E+09 | 2086.23 | 20-DEC-07:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.202570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.655371E+09 | 2926.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.106163E+10 | 2109.02 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.637674E+09 | 3024.23 | 05-FEB-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.457321E+09 | 2046.51 | 09-MAR-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 5083107.36 | 467.58 | 03-APR-05:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 15741521.08 | 544.49 | 28-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.133921E+09 | 953.23 | 16-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.763017E+09 | 2201.54 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.307438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.106163E+10 | 3024.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.703512E+09 | 1552.05 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.418727E+09 | 2171.82 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.278389E+09 | 1393.70 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 2739347.51 | 248.67 | 28-OCT-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63480467.01 | 634.98 | 16-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.469346E+09 | 1598.29 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193619E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.703512E+09 | 2171.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.704485E+09 | 1553.12 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.418938E+09 | 2170.32 | 05-FEB-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.278739E+09 | 1394.00 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 2759253.13 | 248.32 | 28-OCT-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63839391.50 | 636.89 | 16-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.471118E+09 | 1599.98 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193988E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.704485E+09 | 2170.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.348006E+09 | 1316.75 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.235173E+09 | 2033.20 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.204603E+09 | 1227.82 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 13388995.98 | 399.57 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.251262E+09 | 1438.75 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.348006E+09 | 2033.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.348755E+09 | 1318.16 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.235548E+09 | 2033.77 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.205071E+09 | 1229.08 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 8867.70 | 28.01 | 28-OCT-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 13520072.14 | 401.33 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.252345E+09 | 1441.70 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.348755E+09 | 2033.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.755234E+09 | 0.595968E+09 | 2601.65 | 19-JAN-15:30 | 1996.35 | 0.00 |
| February | 0.00 | 0.00 | 0.869727E+09 | 0.675752E+09 | 2305.61 | 27-FEB-16:10 | 1930.97 | 0.00 |
| March | 0.00 | 0.00 | 0.929470E+09 | 0.704825E+09 | 2162.80 | 06-MAR-16:10 | 1661.64 | 0.00 |
| April | 0.00 | 0.00 | 0.187626E+10 | 0.143300E+10 | 2931.70 | 29-APR-16:03 | 2111.81 | 0.00 |
| May | 0.00 | 0.00 | 0.440769E+10 | 0.311184E+10 | 2793.86 | 28-MAY-17:10 | 2141.42 | 0.00 |
| June | 0.00 | 0.00 | 0.466819E+10 | 0.332490E+10 | 3078.73 | 17-JUN-16:30 | 2305.54 | 0.00 |
| July | 0.00 | 0.00 | 0.558450E+10 | 0.380713E+10 | 3379.31 | 22-JUL-16:30 | 2582.30 | 0.00 |
| August | 0.00 | 0.00 | 0.588930E+10 | 0.415376E+10 | 3467.68 | 03-AUG-16:02 | 2794.90 | 0.00 |
| September | 0.00 | 0.00 | 0.548017E+10 | 0.383148E+10 | 3938.62 | 10-SEP-16:02 | 2999.92 | 0.00 |
| October | 0.00 | 0.00 | 0.495158E+10 | 0.368414E+10 | 4099.89 | 08-OCT-15:30 | 2976.92 | 0.00 |
| November | 0.00 | 0.00 | 0.243922E+10 | 0.198739E+10 | 3199.05 | 02-NOV-15:10 | 2472.30 | 0.00 |
| December | 0.00 | 0.00 | 0.153363E+10 | 0.121817E+10 | 2845.08 | 16-DEC-13:30 | 2240.78 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.393850E+11 | 0.285284E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.755234E+09 | 0.595968E+09 | 2162.80 | 1661.64 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.588930E+10 | 0.415376E+10 | 4099.89 | 2999.92 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.278826E+09 | 0.199418E+09 | 1532.70 | 19-JAN-16:10 | 1079.16 | 0.00 |
| February | 0.00 | 0.00 | 0.377082E+09 | 0.271480E+09 | 1507.74 | 27-FEB-17:05 | 1172.37 | 0.00 |
| March | 0.00 | 0.00 | 0.576802E+09 | 0.411983E+09 | 1636.43 | 28-MAR-16:10 | 1116.87 | 0.00 |
| April | 0.00 | 0.00 | 0.159063E+10 | 0.118532E+10 | 2681.73 | 29-APR-16:03 | 1904.97 | 0.00 |
| May | 0.00 | 0.00 | 0.439382E+10 | 0.309518E+10 | 2785.86 | 28-MAY-17:10 | 2147.91 | 0.00 |
| June | 0.00 | 0.00 | 0.476420E+10 | 0.340316E+10 | 3168.85 | 28-JUN-17:30 | 2429.33 | 0.00 |
| July | 0.00 | 0.00 | 0.562124E+10 | 0.383712E+10 | 3337.93 | 03-JUL-16:40 | 2261.18 | 0.00 |
| August | 0.00 | 0.00 | 0.574492E+10 | 0.402154E+10 | 3444.24 | 03-AUG-16:40 | 2762.56 | 0.00 |
| September | 0.00 | 0.00 | 0.509158E+10 | 0.349239E+10 | 3650.95 | 09-SEP-17:10 | 2773.84 | 0.00 |
| October | 0.00 | 0.00 | 0.414093E+10 | 0.296083E+10 | 3451.48 | 08-OCT-16:03 | 2417.07 | 0.00 |
| November | 0.00 | 0.00 | 0.143215E+10 | 0.106558E+10 | 2469.62 | 02-NOV-16:03 | 1817.02 | 0.00 |
| December | 0.00 | 0.00 | 0.816078E+09 | 0.579207E+09 | 1982.33 | 14-DEC-16:10 | 1446.25 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.348283E+11 | 0.245232E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.278826E+09 | 0.199418E+09 | 1507.74 | 1079.16 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.574492E+10 | 0.402154E+10 | 3650.95 | 2773.84 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.817823E+09 | 0.694776E+09 | 7932.89 | 31-JAN-09:02 | 5053.54 | 0.00 |
| February | 0.00 | 0.00 | 0.985661E+09 | 0.809005E+09 | 7882.57 | 27-FEB-08:62 | 5596.27 | 0.00 |
| March | 0.00 | 0.00 | 0.110667E+10 | 0.902918E+09 | 7977.62 | 07-MAR-09:02 | 4972.92 | 0.00 |
| April | 0.00 | 0.00 | 0.155402E+10 | 0.127703E+10 | 8251.86 | 28-APR-07:03 | 4653.64 | 0.00 |
| May | 0.00 | 0.00 | 0.316823E+10 | 0.238894E+10 | 8360.27 | 23-MAY-07:02 | 4167.14 | 0.00 |
| June | 0.00 | 0.00 | 0.344098E+10 | 0.257013E+10 | 8356.80 | 30-JUN-07:02 | 4495.90 | 0.00 |
| July | 0.00 | 0.00 | 0.371697E+10 | 0.265903E+10 | 8358.89 | 14-JUL-07:02 | 4281.17 | 0.00 |
| August | 0.00 | 0.00 | 0.426128E+10 | 0.311597E+10 | 8361.32 | 28-AUG-06:03 | 4931.15 | 0.00 |
| September | 0.00 | 0.00 | 0.366194E+10 | 0.264647E+10 | 8361.87 | 05-SEP-06:03 | 4573.98 | 0.00 |
| October | 0.00 | 0.00 | 0.341357E+10 | 0.267407E+10 | 8361.87 | 23-OCT-06:02 | 4455.14 | 0.00 |
| November | 0.00 | 0.00 | 0.195543E+10 | 0.165210E+10 | 8353.67 | 02-NOV-07:02 | 4504.96 | 0.00 |
| December | 0.00 | 0.00 | 0.121280E+10 | 0.101426E+10 | 8217.59 | 15-DEC-08:62 | 4756.16 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.292954E+11 | 0.224047E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.817823E+09 | 0.694776E+09 | 7882.57 | 4167.14 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.426128E+10 | 0.311597E+10 | 8361.87 | 5596.27 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.259348E+09 | 0.184707E+09 | 1399.34 | 19-JAN-12:00 | 945.44 | 0.00 |
| February | 0.00 | 0.00 | 0.341050E+09 | 0.242871E+09 | 1330.44 | 02-FEB-13:00 | 983.08 | 0.00 |
| March | 0.00 | 0.00 | 0.603868E+09 | 0.430953E+09 | 1667.67 | 30-MAR-13:00 | 1245.96 | 0.00 |
| April | 0.00 | 0.00 | 0.158650E+10 | 0.117886E+10 | 2365.50 | 29-APR-16:03 | 1652.53 | 0.00 |
| May | 0.00 | 0.00 | 0.449154E+10 | 0.317334E+10 | 2622.94 | 26-MAY-11:00 | 1718.41 | 0.00 |
| June | 0.00 | 0.00 | 0.482650E+10 | 0.345282E+10 | 2867.86 | 28-JUN-18:00 | 2146.78 | 0.00 |
| July | 0.00 | 0.00 | 0.572107E+10 | 0.392054E+10 | 3207.30 | 03-JUL-16:40 | 2150.41 | 0.00 |
| August | 0.00 | 0.00 | 0.576603E+10 | 0.403661E+10 | 3184.17 | 03-AUG-16:02 | 2522.10 | 0.00 |
| September | 0.00 | 0.00 | 0.509141E+10 | 0.348934E+10 | 3432.22 | 10-SEP-10:30 | 2427.31 | 0.00 |
| October | 0.00 | 0.00 | 0.412384E+10 | 0.294133E+10 | 3185.99 | 08-OCT-14:00 | 2190.66 | 0.00 |
| November | 0.00 | 0.00 | 0.142273E+10 | 0.105495E+10 | 2213.43 | 02-NOV-15:10 | 1584.47 | 0.00 |
| December | 0.00 | 0.00 | 0.770815E+09 | 0.540812E+09 | 1816.46 | 16-DEC-13:00 | 1332.97 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.350047E+11 | 0.246471E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.259348E+09 | 0.184707E+09 | 1330.44 | 945.44 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.576603E+10 | 0.403661E+10 | 3432.22 | 2522.10 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.249983E+09 | 0.176848E+09 | 1092.53 | 19-JAN-17:10 | 764.46 | 0.00 |
| February | 0.00 | 0.00 | 0.342836E+09 | 0.242787E+09 | 1146.35 | 02-FEB-13:00 | 840.00 | 0.00 |
| March | 0.00 | 0.00 | 0.573930E+09 | 0.406810E+09 | 1422.24 | 28-MAR-16:10 | 983.87 | 0.00 |
| April | 0.00 | 0.00 | 0.150397E+10 | 0.110833E+10 | 1990.23 | 29-APR-16:03 | 1388.87 | 0.00 |
| May | 0.00 | 0.00 | 0.396078E+10 | 0.277278E+10 | 2197.04 | 26-MAY-11:00 | 1425.10 | 0.00 |
| June | 0.00 | 0.00 | 0.423580E+10 | 0.298460E+10 | 2463.95 | 28-JUN-18:00 | 1826.62 | 0.00 |
| July | 0.00 | 0.00 | 0.495491E+10 | 0.333748E+10 | 2701.64 | 03-JUL-16:40 | 1807.54 | 0.00 |
| August | 0.00 | 0.00 | 0.493718E+10 | 0.340546E+10 | 2642.00 | 17-AUG-16:02 | 1757.40 | 0.00 |
| September | 0.00 | 0.00 | 0.440452E+10 | 0.298240E+10 | 2807.07 | 09-SEP-17:10 | 2070.38 | 0.00 |
| October | 0.00 | 0.00 | 0.356978E+10 | 0.252736E+10 | 2612.59 | 08-OCT-16:03 | 1788.65 | 0.00 |
| November | 0.00 | 0.00 | 0.132838E+10 | 0.983035E+09 | 1899.71 | 02-NOV-16:03 | 1353.38 | 0.00 |
| December | 0.00 | 0.00 | 0.749357E+09 | 0.526513E+09 | 1562.63 | 13-DEC-13:50 | 1103.27 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.308114E+11 | 0.214544E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.249983E+09 | 0.176848E+09 | 1092.53 | 764.46 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.495491E+10 | 0.340546E+10 | 2807.07 | 2070.38 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.248979E+09 | 0.176122E+09 | 1085.97 | 19-JAN-17:10 | 759.35 | 0.00 |
| February | 0.00 | 0.00 | 0.340592E+09 | 0.241086E+09 | 1146.25 | 02-FEB-13:00 | 839.87 | 0.00 |
| March | 0.00 | 0.00 | 0.575479E+09 | 0.407952E+09 | 1424.91 | 28-MAR-16:10 | 986.08 | 0.00 |
| April | 0.00 | 0.00 | 0.150548E+10 | 0.110958E+10 | 1986.78 | 29-APR-16:03 | 1386.37 | 0.00 |
| May | 0.00 | 0.00 | 0.396530E+10 | 0.277647E+10 | 2198.75 | 26-MAY-11:00 | 1426.47 | 0.00 |
| June | 0.00 | 0.00 | 0.423875E+10 | 0.298699E+10 | 2459.62 | 28-JUN-18:00 | 1823.00 | 0.00 |
| July | 0.00 | 0.00 | 0.495954E+10 | 0.334130E+10 | 2699.80 | 03-JUL-16:40 | 1806.12 | 0.00 |
| August | 0.00 | 0.00 | 0.493847E+10 | 0.340644E+10 | 2639.54 | 17-AUG-16:02 | 1755.41 | 0.00 |
| September | 0.00 | 0.00 | 0.440484E+10 | 0.298253E+10 | 2801.58 | 09-SEP-17:10 | 2065.63 | 0.00 |
| October | 0.00 | 0.00 | 0.356951E+10 | 0.252702E+10 | 2607.82 | 08-OCT-16:03 | 1784.84 | 0.00 |
| November | 0.00 | 0.00 | 0.132971E+10 | 0.984220E+09 | 1896.00 | 02-NOV-16:03 | 1350.58 | 0.00 |
| December | 0.00 | 0.00 | 0.747010E+09 | 0.524584E+09 | 1560.58 | 13-DEC-13:50 | 1101.54 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.308237E+11 | 0.214643E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.248979E+09 | 0.176122E+09 | 1085.97 | 759.35 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.495954E+10 | 0.340644E+10 | 2801.58 | 2065.63 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.859598E+09 | 0.694701E+09 | 2219.10 | 19-JAN-14:00 | 1696.95 | 0.00 |
| February | 0.00 | 0.00 | 0.926054E+09 | 0.723289E+09 | 1979.38 | 02-FEB-13:00 | 1579.84 | 0.00 |
| March | 0.00 | 0.00 | 0.981713E+09 | 0.748794E+09 | 1795.84 | 06-MAR-13:00 | 1363.00 | 0.00 |
| April | 0.00 | 0.00 | 0.182583E+10 | 0.138878E+10 | 2239.62 | 29-APR-16:03 | 1595.01 | 0.00 |
| May | 0.00 | 0.00 | 0.398890E+10 | 0.280275E+10 | 2162.62 | 26-MAY-11:00 | 1404.42 | 0.00 |
| June | 0.00 | 0.00 | 0.415071E+10 | 0.291769E+10 | 2373.17 | 17-JUN-16:40 | 1723.00 | 0.00 |
| July | 0.00 | 0.00 | 0.493219E+10 | 0.332126E+10 | 2702.03 | 22-JUL-16:10 | 2001.34 | 0.00 |
| August | 0.00 | 0.00 | 0.509887E+10 | 0.355296E+10 | 2675.45 | 17-AUG-16:02 | 1809.01 | 0.00 |
| September | 0.00 | 0.00 | 0.481644E+10 | 0.334059E+10 | 3193.33 | 10-SEP-13:30 | 2295.91 | 0.00 |
| October | 0.00 | 0.00 | 0.441535E+10 | 0.328236E+10 | 3323.11 | 08-OCT-14:00 | 2404.80 | 0.00 |
| November | 0.00 | 0.00 | 0.242598E+10 | 0.199081E+10 | 2760.09 | 07-NOV-13:30 | 2031.24 | 0.00 |
| December | 0.00 | 0.00 | 0.158363E+10 | 0.127320E+10 | 2589.49 | 16-DEC-13:00 | 2040.27 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.360052E+11 | 0.260372E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.859598E+09 | 0.694701E+09 | 1795.84 | 1363.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.509887E+10 | 0.355296E+10 | 3323.11 | 2404.80 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.946748E+09 | 0.772800E+09 | 2326.76 | 01-JAN-14:00 | 2118.46 | 0.00 |
| February | 0.00 | 0.00 | 0.995108E+09 | 0.781801E+09 | 2029.78 | 02-FEB-13:00 | 1628.04 | 0.00 |
| March | 0.00 | 0.00 | 0.107655E+10 | 0.828349E+09 | 1868.06 | 07-MAR-11:30 | 1316.07 | 0.00 |
| April | 0.00 | 0.00 | 0.199266E+10 | 0.152871E+10 | 2366.05 | 29-APR-16:03 | 1706.05 | 0.00 |
| May | 0.00 | 0.00 | 0.431266E+10 | 0.307694E+10 | 2298.53 | 28-MAY-17:10 | 1745.38 | 0.00 |
| June | 0.00 | 0.00 | 0.447781E+10 | 0.319855E+10 | 2513.72 | 17-JUN-16:40 | 1852.80 | 0.00 |
| July | 0.00 | 0.00 | 0.531405E+10 | 0.364761E+10 | 2857.41 | 23-JUL-17:10 | 2023.31 | 0.00 |
| August | 0.00 | 0.00 | 0.546533E+10 | 0.386959E+10 | 2791.63 | 13-AUG-15:10 | 1901.93 | 0.00 |
| September | 0.00 | 0.00 | 0.517084E+10 | 0.364437E+10 | 3378.27 | 10-SEP-13:30 | 2467.57 | 0.00 |
| October | 0.00 | 0.00 | 0.474733E+10 | 0.357578E+10 | 3511.60 | 08-OCT-14:00 | 2578.84 | 0.00 |
| November | 0.00 | 0.00 | 0.261678E+10 | 0.216426E+10 | 2860.95 | 07-NOV-13:40 | 2125.16 | 0.00 |
| December | 0.00 | 0.00 | 0.170819E+10 | 0.138372E+10 | 2714.16 | 16-DEC-13:00 | 2156.81 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.388240E+11 | 0.284725E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.946748E+09 | 0.772800E+09 | 1868.06 | 1316.07 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.546533E+10 | 0.386959E+10 | 3511.60 | 2578.84 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.181324E+10 | 0.144431E+10 | 6387.11 | 19-JAN-15:30 | 4929.99 | 0.00 |
| February | 0.00 | 0.00 | 0.260590E+10 | 0.208430E+10 | 5777.38 | 27-FEB-16:10 | 4895.91 | 0.00 |
| March | 0.00 | 0.00 | 0.307050E+10 | 0.242419E+10 | 5791.45 | 06-MAR-16:10 | 4527.50 | 0.00 |
| April | 0.00 | 0.00 | 0.558693E+10 | 0.439938E+10 | 7417.45 | 29-APR-16:03 | 5415.21 | 0.00 |
| May | 0.00 | 0.00 | 0.106227E+11 | 0.761560E+10 | 6737.16 | 28-MAY-17:10 | 5216.60 | 0.00 |
| June | 0.00 | 0.00 | 0.107688E+11 | 0.777372E+10 | 7185.60 | 17-JUN-16:30 | 5456.78 | 0.00 |
| July | 0.00 | 0.00 | 0.121326E+11 | 0.825787E+10 | 7466.57 | 22-JUL-16:30 | 5753.33 | 0.00 |
| August | 0.00 | 0.00 | 0.119572E+11 | 0.827356E+10 | 7574.48 | 03-AUG-16:02 | 6051.00 | 0.00 |
| September | 0.00 | 0.00 | 0.109940E+11 | 0.751405E+10 | 8487.94 | 09-SEP-17:00 | 6475.54 | 0.00 |
| October | 0.00 | 0.00 | 0.988028E+10 | 0.719956E+10 | 9127.96 | 08-OCT-15:30 | 6504.66 | 0.00 |
| November | 0.00 | 0.00 | 0.487225E+10 | 0.395117E+10 | 7229.30 | 02-NOV-15:10 | 5593.02 | 0.00 |
| December | 0.00 | 0.00 | 0.319784E+10 | 0.254315E+10 | 6478.68 | 16-DEC-13:30 | 5097.31 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.875023E+11 | 0.634809E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.181324E+10 | 0.144431E+10 | 5777.38 | 4527.50 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.121326E+11 | 0.827356E+10 | 9127.96 | 6504.66 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.782390E+09 | 0.558496E+09 | 3847.86 | 19-JAN-16:10 | 2753.68 | 0.00 |
| February | 0.00 | 0.00 | 0.134508E+10 | 0.994892E+09 | 3928.86 | 27-FEB-17:03 | 3120.61 | 0.00 |
| March | 0.00 | 0.00 | 0.218543E+10 | 0.163435E+10 | 4418.10 | 28-MAR-16:10 | 3059.22 | 0.00 |
| April | 0.00 | 0.00 | 0.493133E+10 | 0.380752E+10 | 6817.93 | 29-APR-16:03 | 4913.50 | 0.00 |
| May | 0.00 | 0.00 | 0.105708E+11 | 0.756424E+10 | 6715.60 | 28-MAY-17:10 | 5224.47 | 0.00 |
| June | 0.00 | 0.00 | 0.109368E+11 | 0.791393E+10 | 7432.22 | 28-JUN-17:30 | 5754.28 | 0.00 |
| July | 0.00 | 0.00 | 0.121720E+11 | 0.829220E+10 | 7572.78 | 03-JUL-16:30 | 5073.56 | 0.00 |
| August | 0.00 | 0.00 | 0.116139E+11 | 0.796851E+10 | 7508.38 | 03-AUG-16:13 | 5953.25 | 0.00 |
| September | 0.00 | 0.00 | 0.101401E+11 | 0.678376E+10 | 7896.74 | 09-SEP-17:10 | 5940.36 | 0.00 |
| October | 0.00 | 0.00 | 0.813154E+10 | 0.566376E+10 | 7498.82 | 08-OCT-16:03 | 5123.36 | 0.00 |
| November | 0.00 | 0.00 | 0.276302E+10 | 0.202323E+10 | 5364.59 | 02-NOV-16:03 | 3928.14 | 0.00 |
| December | 0.00 | 0.00 | 0.166608E+10 | 0.117372E+10 | 4371.27 | 14-DEC-16:10 | 3181.28 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.772384E+11 | 0.543786E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.782390E+09 | 0.558496E+09 | 3847.86 | 2753.68 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.121720E+11 | 0.829220E+10 | 7896.74 | 5953.25 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.173990E+10 | 0.137914E+10 | 6046.19 | 19-JAN-14:00 | 4580.37 | 0.00 |
| February | 0.00 | 0.00 | 0.252868E+10 | 0.201817E+10 | 5513.77 | 02-FEB-13:00 | 4447.15 | 0.00 |
| March | 0.00 | 0.00 | 0.314120E+10 | 0.248161E+10 | 5614.85 | 07-MAR-11:30 | 4067.72 | 0.00 |
| April | 0.00 | 0.00 | 0.557105E+10 | 0.438574E+10 | 6512.76 | 29-APR-16:03 | 4671.82 | 0.00 |
| May | 0.00 | 0.00 | 0.108166E+11 | 0.777987E+10 | 6294.01 | 28-MAY-10:00 | 4316.91 | 0.00 |
| June | 0.00 | 0.00 | 0.108903E+11 | 0.787821E+10 | 6478.39 | 28-JUN-15:10 | 4762.74 | 0.00 |
| July | 0.00 | 0.00 | 0.123305E+11 | 0.843154E+10 | 7314.46 | 19-JUL-13:00 | 5610.97 | 0.00 |
| August | 0.00 | 0.00 | 0.119878E+11 | 0.830213E+10 | 6908.49 | 17-AUG-16:02 | 4573.28 | 0.00 |
| September | 0.00 | 0.00 | 0.109799E+11 | 0.750515E+10 | 8208.83 | 10-SEP-12:00 | 5988.26 | 0.00 |
| October | 0.00 | 0.00 | 0.982573E+10 | 0.714864E+10 | 8627.93 | 08-OCT-14:00 | 6121.96 | 0.00 |
| November | 0.00 | 0.00 | 0.486250E+10 | 0.394331E+10 | 7037.86 | 07-NOV-13:30 | 5107.65 | 0.00 |
| December | 0.00 | 0.00 | 0.305942E+10 | 0.241911E+10 | 6606.43 | 16-DEC-13:00 | 5212.62 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.877336E+11 | 0.636726E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.173990E+10 | 0.137914E+10 | 5513.77 | 4067.72 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.123305E+11 | 0.843154E+10 | 8627.93 | 6121.96 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.734534E+09 | 0.520812E+09 | 3474.54 | 19-JAN-12:00 | 2402.13 | 0.00 |
| February | 0.00 | 0.00 | 0.126598E+10 | 0.927957E+09 | 3597.79 | 24-FEB-13:00 | 2673.15 | 0.00 |
| March | 0.00 | 0.00 | 0.225008E+10 | 0.167965E+10 | 4455.32 | 28-MAR-16:10 | 3092.03 | 0.00 |
| April | 0.00 | 0.00 | 0.491844E+10 | 0.378875E+10 | 5926.33 | 29-APR-16:03 | 4185.62 | 0.00 |
| May | 0.00 | 0.00 | 0.107767E+11 | 0.772862E+10 | 6231.16 | 26-MAY-11:00 | 4153.04 | 0.00 |
| June | 0.00 | 0.00 | 0.110687E+11 | 0.801843E+10 | 6627.55 | 28-JUN-18:00 | 4980.76 | 0.00 |
| July | 0.00 | 0.00 | 0.123808E+11 | 0.846569E+10 | 7321.80 | 19-JUL-13:00 | 5595.80 | 0.00 |
| August | 0.00 | 0.00 | 0.116579E+11 | 0.799756E+10 | 6844.21 | 17-AUG-16:02 | 4470.62 | 0.00 |
| September | 0.00 | 0.00 | 0.101397E+11 | 0.677619E+10 | 7300.44 | 10-SEP-10:30 | 5083.18 | 0.00 |
| October | 0.00 | 0.00 | 0.809135E+10 | 0.561536E+10 | 6783.13 | 08-OCT-14:00 | 4524.66 | 0.00 |
| November | 0.00 | 0.00 | 0.273692E+10 | 0.199398E+10 | 4707.04 | 07-NOV-13:40 | 3096.74 | 0.00 |
| December | 0.00 | 0.00 | 0.157350E+10 | 0.109529E+10 | 3906.04 | 16-DEC-13:00 | 2836.71 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.775945E+11 | 0.546083E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.734534E+09 | 0.520812E+09 | 3474.54 | 2402.13 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.123808E+11 | 0.846569E+10 | 7321.80 | 5595.80 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.744268E+09 | 0.526898E+09 | 2701.09 | 31-JAN-16:10 | 1858.45 | 0.00 |
| February | 0.00 | 0.00 | 0.122279E+10 | 0.891901E+09 | 2872.35 | 24-FEB-13:00 | 2068.99 | 0.00 |
| March | 0.00 | 0.00 | 0.200933E+10 | 0.149201E+10 | 3619.45 | 28-MAR-16:10 | 2539.53 | 0.00 |
| April | 0.00 | 0.00 | 0.428869E+10 | 0.327162E+10 | 4721.42 | 29-APR-16:03 | 3328.13 | 0.00 |
| May | 0.00 | 0.00 | 0.901793E+10 | 0.638851E+10 | 4979.69 | 26-MAY-11:00 | 3276.64 | 0.00 |
| June | 0.00 | 0.00 | 0.929303E+10 | 0.661041E+10 | 5471.77 | 28-JUN-18:00 | 4073.91 | 0.00 |
| July | 0.00 | 0.00 | 0.103920E+11 | 0.698113E+10 | 5869.74 | 03-JUL-16:40 | 3891.67 | 0.00 |
| August | 0.00 | 0.00 | 0.982977E+10 | 0.666570E+10 | 5596.33 | 17-AUG-16:03 | 3656.16 | 0.00 |
| September | 0.00 | 0.00 | 0.869388E+10 | 0.576554E+10 | 5774.83 | 09-SEP-17:10 | 4207.07 | 0.00 |
| October | 0.00 | 0.00 | 0.695990E+10 | 0.481901E+10 | 5432.91 | 08-OCT-16:03 | 3624.33 | 0.00 |
| November | 0.00 | 0.00 | 0.262659E+10 | 0.192492E+10 | 3929.12 | 02-NOV-16:02 | 2777.17 | 0.00 |
| December | 0.00 | 0.00 | 0.155299E+10 | 0.108632E+10 | 3302.33 | 13-DEC-14:00 | 2349.39 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.666312E+11 | 0.464240E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.744268E+09 | 0.526898E+09 | 2701.09 | 1858.45 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.103920E+11 | 0.698113E+10 | 5869.74 | 4207.07 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.742329E+09 | 0.525413E+09 | 2690.75 | 31-JAN-16:10 | 1850.74 | 0.00 |
| February | 0.00 | 0.00 | 0.121964E+10 | 0.889382E+09 | 2883.06 | 24-FEB-13:00 | 2078.54 | 0.00 |
| March | 0.00 | 0.00 | 0.201342E+10 | 0.149521E+10 | 3625.63 | 28-MAR-16:10 | 2544.61 | 0.00 |
| April | 0.00 | 0.00 | 0.429114E+10 | 0.327381E+10 | 4713.51 | 29-APR-16:03 | 3322.38 | 0.00 |
| May | 0.00 | 0.00 | 0.902590E+10 | 0.639498E+10 | 4982.63 | 26-MAY-11:00 | 3278.90 | 0.00 |
| June | 0.00 | 0.00 | 0.929837E+10 | 0.661471E+10 | 5460.33 | 28-JUN-18:00 | 4064.22 | 0.00 |
| July | 0.00 | 0.00 | 0.104002E+11 | 0.698784E+10 | 5865.29 | 03-JUL-16:40 | 3888.19 | 0.00 |
| August | 0.00 | 0.00 | 0.983221E+10 | 0.666748E+10 | 5591.07 | 17-AUG-16:03 | 3651.98 | 0.00 |
| September | 0.00 | 0.00 | 0.869461E+10 | 0.576586E+10 | 5760.93 | 09-SEP-17:10 | 4195.12 | 0.00 |
| October | 0.00 | 0.00 | 0.695927E+10 | 0.481823E+10 | 5421.25 | 08-OCT-16:03 | 3615.20 | 0.00 |
| November | 0.00 | 0.00 | 0.263015E+10 | 0.192808E+10 | 3920.93 | 02-NOV-16:02 | 2771.17 | 0.00 |
| December | 0.00 | 0.00 | 0.154898E+10 | 0.108304E+10 | 3298.31 | 13-DEC-14:00 | 2346.07 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.666563E+11 | 0.464440E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.742329E+09 | 0.525413E+09 | 2690.75 | 1850.74 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.104002E+11 | 0.698784E+10 | 5865.29 | 4195.12 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.206586E+10 | 0.169433E+10 | 5320.21 | 19-JAN-14:00 | 4101.76 | 0.00 |
| February | 0.00 | 0.00 | 0.266920E+10 | 0.215290E+10 | 4843.25 | 02-FEB-13:00 | 3926.88 | 0.00 |
| March | 0.00 | 0.00 | 0.297446E+10 | 0.236118E+10 | 4500.99 | 06-MAR-13:00 | 3494.38 | 0.00 |
| April | 0.00 | 0.00 | 0.495874E+10 | 0.388271E+10 | 5296.47 | 29-APR-16:03 | 3811.42 | 0.00 |
| May | 0.00 | 0.00 | 0.905883E+10 | 0.644045E+10 | 4902.39 | 26-MAY-11:00 | 3227.77 | 0.00 |
| June | 0.00 | 0.00 | 0.911071E+10 | 0.646928E+10 | 5188.46 | 17-JUN-16:15 | 3784.30 | 0.00 |
| July | 0.00 | 0.00 | 0.103402E+11 | 0.694681E+10 | 5710.05 | 03-JUL-16:30 | 3796.89 | 0.00 |
| August | 0.00 | 0.00 | 0.101644E+11 | 0.697167E+10 | 5658.22 | 17-AUG-16:02 | 3758.79 | 0.00 |
| September | 0.00 | 0.00 | 0.954439E+10 | 0.650053E+10 | 6654.41 | 10-SEP-13:30 | 4754.47 | 0.00 |
| October | 0.00 | 0.00 | 0.873233E+10 | 0.639195E+10 | 7149.81 | 08-OCT-14:00 | 5111.69 | 0.00 |
| November | 0.00 | 0.00 | 0.490704E+10 | 0.402641E+10 | 6022.40 | 07-NOV-13:30 | 4406.33 | 0.00 |
| December | 0.00 | 0.00 | 0.333130E+10 | 0.269280E+10 | 5820.23 | 16-DEC-13:00 | 4609.56 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.778575E+11 | 0.565310E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.206586E+10 | 0.169433E+10 | 4500.99 | 3227.77 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.103402E+11 | 0.697167E+10 | 7149.81 | 5111.69 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.206892E+10 | 0.169751E+10 | 5327.92 | 19-JAN-14:00 | 4108.97 | 0.00 |
| February | 0.00 | 0.00 | 0.266911E+10 | 0.215308E+10 | 4848.38 | 02-FEB-13:00 | 3931.63 | 0.00 |
| March | 0.00 | 0.00 | 0.298067E+10 | 0.236662E+10 | 4515.39 | 06-MAR-13:00 | 3507.82 | 0.00 |
| April | 0.00 | 0.00 | 0.496063E+10 | 0.388439E+10 | 5288.40 | 29-APR-16:03 | 3805.31 | 0.00 |
| May | 0.00 | 0.00 | 0.906682E+10 | 0.644695E+10 | 4905.33 | 26-MAY-11:00 | 3230.04 | 0.00 |
| June | 0.00 | 0.00 | 0.911617E+10 | 0.647365E+10 | 5178.15 | 17-JUN-16:15 | 3776.19 | 0.00 |
| July | 0.00 | 0.00 | 0.103485E+11 | 0.695355E+10 | 5713.10 | 23-JUL-16:10 | 4045.92 | 0.00 |
| August | 0.00 | 0.00 | 0.101668E+11 | 0.697342E+10 | 5653.00 | 17-AUG-16:02 | 3754.59 | 0.00 |
| September | 0.00 | 0.00 | 0.954506E+10 | 0.650081E+10 | 6663.22 | 10-SEP-13:30 | 4763.14 | 0.00 |
| October | 0.00 | 0.00 | 0.873172E+10 | 0.639108E+10 | 7150.49 | 08-OCT-14:00 | 5112.89 | 0.00 |
| November | 0.00 | 0.00 | 0.490930E+10 | 0.402847E+10 | 6030.00 | 07-NOV-13:30 | 4413.58 | 0.00 |
| December | 0.00 | 0.00 | 0.332698E+10 | 0.268891E+10 | 5827.01 | 16-DEC-13:00 | 4616.01 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.778907E+11 | 0.565584E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.206892E+10 | 0.169751E+10 | 4515.39 | 3230.04 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.103485E+11 | 0.697342E+10 | 7150.49 | 5112.89 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.888031E+09 | 0.729201E+09 | 4032.63 | 19-JAN-15:30 | 3157.66 | 0.00 |
| February | 0.00 | 0.00 | 0.121507E+10 | 0.992224E+09 | 3678.40 | 27-FEB-16:10 | 3160.90 | 0.00 |
| March | 0.00 | 0.00 | 0.151154E+10 | 0.121397E+10 | 3685.59 | 06-MAR-16:10 | 2918.05 | 0.00 |
| April | 0.00 | 0.00 | 0.276583E+10 | 0.220718E+10 | 4862.14 | 29-APR-16:03 | 3642.79 | 0.00 |
| May | 0.00 | 0.00 | 0.590152E+10 | 0.428568E+10 | 4500.81 | 28-MAY-16:50 | 3690.30 | 0.00 |
| June | 0.00 | 0.00 | 0.606568E+10 | 0.445972E+10 | 4694.57 | 28-JUN-15:20 | 3603.74 | 0.00 |
| July | 0.00 | 0.00 | 0.682098E+10 | 0.471533E+10 | 4915.58 | 22-JUL-16:30 | 3960.09 | 0.00 |
| August | 0.00 | 0.00 | 0.669047E+10 | 0.469290E+10 | 5043.74 | 03-AUG-16:02 | 4142.24 | 0.00 |
| September | 0.00 | 0.00 | 0.595804E+10 | 0.410459E+10 | 5497.62 | 09-SEP-16:40 | 4332.63 | 0.00 |
| October | 0.00 | 0.00 | 0.526415E+10 | 0.384903E+10 | 5928.67 | 08-OCT-15:30 | 4335.18 | 0.00 |
| November | 0.00 | 0.00 | 0.219048E+10 | 0.176933E+10 | 4692.05 | 02-NOV-15:10 | 3741.10 | 0.00 |
| December | 0.00 | 0.00 | 0.149961E+10 | 0.121038E+10 | 4128.38 | 16-DEC-13:40 | 3319.12 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.467714E+11 | 0.342295E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.888031E+09 | 0.729201E+09 | 3678.40 | 2918.05 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.682098E+10 | 0.471533E+10 | 5928.67 | 4335.18 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.396586E+09 | 0.291529E+09 | 2515.13 | 31-JAN-16:10 | 1791.37 | 0.00 |
| February | 0.00 | 0.00 | 0.625682E+09 | 0.471984E+09 | 2448.42 | 27-FEB-16:30 | 1975.62 | 0.00 |
| March | 0.00 | 0.00 | 0.109114E+10 | 0.832787E+09 | 2880.76 | 26-MAR-16:10 | 2390.62 | 0.00 |
| April | 0.00 | 0.00 | 0.243685E+10 | 0.190531E+10 | 4479.28 | 29-APR-16:03 | 3313.40 | 0.00 |
| May | 0.00 | 0.00 | 0.587926E+10 | 0.425958E+10 | 4476.47 | 28-MAY-17:10 | 3575.31 | 0.00 |
| June | 0.00 | 0.00 | 0.615641E+10 | 0.453422E+10 | 4805.69 | 28-JUN-17:30 | 3837.13 | 0.00 |
| July | 0.00 | 0.00 | 0.684735E+10 | 0.473644E+10 | 4799.13 | 18-JUL-16:02 | 3862.93 | 0.00 |
| August | 0.00 | 0.00 | 0.650341E+10 | 0.452159E+10 | 4969.19 | 03-AUG-16:13 | 4050.05 | 0.00 |
| September | 0.00 | 0.00 | 0.550191E+10 | 0.370722E+10 | 5102.54 | 09-SEP-17:10 | 3955.17 | 0.00 |
| October | 0.00 | 0.00 | 0.435449E+10 | 0.304350E+10 | 4835.74 | 08-OCT-15:30 | 3360.72 | 0.00 |
| November | 0.00 | 0.00 | 0.124492E+10 | 0.905137E+09 | 3415.32 | 02-NOV-15:20 | 2532.77 | 0.00 |
| December | 0.00 | 0.00 | 0.762474E+09 | 0.546554E+09 | 2734.52 | 13-DEC-15:20 | 2189.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.418005E+11 | 0.297559E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.396586E+09 | 0.291529E+09 | 2448.42 | 1791.37 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.684735E+10 | 0.473644E+10 | 5102.54 | 4050.05 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.834245E+09 | 0.680336E+09 | 3865.31 | 19-JAN-13:40 | 2962.59 | 0.00 |
| February | 0.00 | 0.00 | 0.116625E+10 | 0.947855E+09 | 3431.24 | 24-FEB-13:50 | 2838.81 | 0.00 |
| March | 0.00 | 0.00 | 0.153206E+10 | 0.122782E+10 | 3572.00 | 07-MAR-11:30 | 2612.46 | 0.00 |
| April | 0.00 | 0.00 | 0.274252E+10 | 0.218426E+10 | 4211.70 | 29-APR-16:10 | 3093.44 | 0.00 |
| May | 0.00 | 0.00 | 0.600201E+10 | 0.436842E+10 | 4115.75 | 25-MAY-14:00 | 3198.49 | 0.00 |
| June | 0.00 | 0.00 | 0.613060E+10 | 0.451459E+10 | 4324.75 | 28-JUN-15:10 | 3313.68 | 0.00 |
| July | 0.00 | 0.00 | 0.692590E+10 | 0.480806E+10 | 4879.60 | 19-JUL-13:00 | 3830.40 | 0.00 |
| August | 0.00 | 0.00 | 0.670161E+10 | 0.470297E+10 | 4492.51 | 03-AUG-16:02 | 3643.64 | 0.00 |
| September | 0.00 | 0.00 | 0.594756E+10 | 0.409667E+10 | 5391.81 | 10-SEP-13:00 | 4104.87 | 0.00 |
| October | 0.00 | 0.00 | 0.522590E+10 | 0.381115E+10 | 5614.60 | 08-OCT-14:00 | 4093.76 | 0.00 |
| November | 0.00 | 0.00 | 0.216376E+10 | 0.174315E+10 | 4475.05 | 07-NOV-13:30 | 3314.06 | 0.00 |
| December | 0.00 | 0.00 | 0.141933E+10 | 0.113695E+10 | 4212.66 | 16-DEC-13:00 | 3381.47 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.467918E+11 | 0.342222E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.834245E+09 | 0.680336E+09 | 3431.24 | 2612.46 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.692590E+10 | 0.480806E+10 | 5614.60 | 4104.87 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.363794E+09 | 0.264546E+09 | 2090.63 | 19-JAN-12:00 | 1440.17 | 0.00 |
| February | 0.00 | 0.00 | 0.581436E+09 | 0.434077E+09 | 2174.65 | 24-FEB-13:00 | 1619.26 | 0.00 |
| March | 0.00 | 0.00 | 0.111408E+10 | 0.847783E+09 | 2761.37 | 28-MAR-15:20 | 1983.89 | 0.00 |
| April | 0.00 | 0.00 | 0.241196E+10 | 0.188021E+10 | 3833.27 | 29-APR-16:03 | 2773.92 | 0.00 |
| May | 0.00 | 0.00 | 0.597966E+10 | 0.434229E+10 | 4051.58 | 25-MAY-14:00 | 3130.45 | 0.00 |
| June | 0.00 | 0.00 | 0.622047E+10 | 0.458891E+10 | 4327.16 | 28-JUN-15:10 | 3301.38 | 0.00 |
| July | 0.00 | 0.00 | 0.695175E+10 | 0.482883E+10 | 4858.20 | 19-JUL-13:00 | 3802.85 | 0.00 |
| August | 0.00 | 0.00 | 0.651532E+10 | 0.453162E+10 | 4408.13 | 03-AUG-16:02 | 3542.76 | 0.00 |
| September | 0.00 | 0.00 | 0.549326E+10 | 0.369984E+10 | 4687.60 | 10-SEP-12:00 | 3471.44 | 0.00 |
| October | 0.00 | 0.00 | 0.432751E+10 | 0.301463E+10 | 4414.92 | 08-OCT-14:00 | 3034.27 | 0.00 |
| November | 0.00 | 0.00 | 0.122088E+10 | 0.881869E+09 | 3027.73 | 07-NOV-13:40 | 2042.56 | 0.00 |
| December | 0.00 | 0.00 | 0.707034E+09 | 0.499387E+09 | 2466.06 | 16-DEC-13:00 | 1816.97 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.418871E+11 | 0.298140E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.363794E+09 | 0.264546E+09 | 2090.63 | 1440.17 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.695175E+10 | 0.482883E+10 | 4858.20 | 3802.85 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.335161E+09 | 0.240211E+09 | 1742.97 | 31-JAN-16:10 | 1230.86 | 0.00 |
| February | 0.00 | 0.00 | 0.506093E+09 | 0.372194E+09 | 1677.56 | 24-FEB-14:00 | 1257.40 | 0.00 |
| March | 0.00 | 0.00 | 0.931681E+09 | 0.695712E+09 | 2223.15 | 28-MAR-16:10 | 1581.85 | 0.00 |
| April | 0.00 | 0.00 | 0.205177E+10 | 0.157573E+10 | 3121.51 | 29-APR-16:03 | 2284.40 | 0.00 |
| May | 0.00 | 0.00 | 0.503475E+10 | 0.363130E+10 | 3214.97 | 25-MAY-14:10 | 2479.25 | 0.00 |
| June | 0.00 | 0.00 | 0.526519E+10 | 0.383664E+10 | 3527.02 | 28-JUN-15:10 | 2668.68 | 0.00 |
| July | 0.00 | 0.00 | 0.587228E+10 | 0.403749E+10 | 3691.86 | 03-JUL-16:30 | 2527.82 | 0.00 |
| August | 0.00 | 0.00 | 0.552187E+10 | 0.382003E+10 | 3608.44 | 03-AUG-16:02 | 2898.11 | 0.00 |
| September | 0.00 | 0.00 | 0.472040E+10 | 0.316812E+10 | 3706.51 | 09-SEP-17:10 | 2811.04 | 0.00 |
| October | 0.00 | 0.00 | 0.368665E+10 | 0.256463E+10 | 3505.62 | 08-OCT-14:10 | 2424.13 | 0.00 |
| November | 0.00 | 0.00 | 0.108784E+10 | 0.776562E+09 | 2489.63 | 02-NOV-15:10 | 1810.14 | 0.00 |
| December | 0.00 | 0.00 | 0.668444E+09 | 0.464896E+09 | 2034.06 | 15-DEC-14:00 | 1526.03 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.356821E+11 | 0.251835E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.335161E+09 | 0.240211E+09 | 1677.56 | 1230.86 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.587228E+10 | 0.403749E+10 | 3706.51 | 2898.11 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.334894E+09 | 0.240055E+09 | 1731.70 | 31-JAN-16:10 | 1222.10 | 0.00 |
| February | 0.00 | 0.00 | 0.505506E+09 | 0.371750E+09 | 1690.46 | 24-FEB-13:00 | 1200.93 | 0.00 |
| March | 0.00 | 0.00 | 0.935563E+09 | 0.698902E+09 | 2226.95 | 28-MAR-16:10 | 1584.94 | 0.00 |
| April | 0.00 | 0.00 | 0.205377E+10 | 0.157752E+10 | 3110.50 | 29-APR-16:03 | 2275.59 | 0.00 |
| May | 0.00 | 0.00 | 0.503966E+10 | 0.363507E+10 | 3218.85 | 25-MAY-14:10 | 2483.20 | 0.00 |
| June | 0.00 | 0.00 | 0.526863E+10 | 0.383922E+10 | 3525.80 | 28-JUN-15:10 | 2668.50 | 0.00 |
| July | 0.00 | 0.00 | 0.587720E+10 | 0.404133E+10 | 3690.27 | 19-JUL-13:00 | 2872.39 | 0.00 |
| August | 0.00 | 0.00 | 0.552336E+10 | 0.382091E+10 | 3598.95 | 03-AUG-16:02 | 2889.81 | 0.00 |
| September | 0.00 | 0.00 | 0.472101E+10 | 0.316828E+10 | 3697.00 | 10-SEP-13:20 | 2673.19 | 0.00 |
| October | 0.00 | 0.00 | 0.368678E+10 | 0.256438E+10 | 3506.15 | 08-OCT-14:00 | 2421.37 | 0.00 |
| November | 0.00 | 0.00 | 0.108943E+10 | 0.777922E+09 | 2485.64 | 02-NOV-15:10 | 1807.79 | 0.00 |
| December | 0.00 | 0.00 | 0.667255E+09 | 0.464032E+09 | 2032.18 | 15-DEC-14:00 | 1524.59 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.357031E+11 | 0.251994E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.334894E+09 | 0.240055E+09 | 1690.46 | 1200.93 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.587720E+10 | 0.404133E+10 | 3697.00 | 2889.81 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.842986E+09 | 0.690287E+09 | 3407.88 | 19-JAN-14:00 | 2670.86 | 0.00 |
| February | 0.00 | 0.00 | 0.111020E+10 | 0.901124E+09 | 3010.30 | 24-FEB-14:00 | 2494.14 | 0.00 |
| March | 0.00 | 0.00 | 0.134871E+10 | 0.107276E+10 | 2918.21 | 06-MAR-14:00 | 2318.56 | 0.00 |
| April | 0.00 | 0.00 | 0.239052E+10 | 0.188551E+10 | 3497.13 | 29-APR-16:03 | 2607.42 | 0.00 |
| May | 0.00 | 0.00 | 0.505712E+10 | 0.365763E+10 | 3277.42 | 25-MAY-14:10 | 2545.63 | 0.00 |
| June | 0.00 | 0.00 | 0.517262E+10 | 0.376120E+10 | 3522.56 | 28-JUN-15:10 | 2678.69 | 0.00 |
| July | 0.00 | 0.00 | 0.584527E+10 | 0.401638E+10 | 3777.89 | 22-JUL-16:10 | 2966.43 | 0.00 |
| August | 0.00 | 0.00 | 0.571046E+10 | 0.399278E+10 | 3691.44 | 03-AUG-16:02 | 2999.24 | 0.00 |
| September | 0.00 | 0.00 | 0.517962E+10 | 0.356944E+10 | 4454.11 | 10-SEP-13:20 | 3355.66 | 0.00 |
| October | 0.00 | 0.00 | 0.460505E+10 | 0.338239E+10 | 4699.22 | 08-OCT-14:00 | 3485.40 | 0.00 |
| November | 0.00 | 0.00 | 0.206909E+10 | 0.167224E+10 | 3829.24 | 02-NOV-14:20 | 3073.44 | 0.00 |
| December | 0.00 | 0.00 | 0.142537E+10 | 0.114509E+10 | 3713.46 | 16-DEC-13:30 | 3028.67 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.407570E+11 | 0.297468E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.842986E+09 | 0.690287E+09 | 2918.21 | 2318.56 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.584527E+10 | 0.401638E+10 | 4699.22 | 3485.40 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.844679E+09 | 0.692042E+09 | 3416.42 | 19-JAN-14:00 | 2678.97 | 0.00 |
| February | 0.00 | 0.00 | 0.111105E+10 | 0.902058E+09 | 3018.37 | 24-FEB-14:00 | 2502.43 | 0.00 |
| March | 0.00 | 0.00 | 0.135377E+10 | 0.107723E+10 | 2929.42 | 06-MAR-14:00 | 2329.35 | 0.00 |
| April | 0.00 | 0.00 | 0.239272E+10 | 0.188753E+10 | 3486.26 | 29-APR-16:03 | 2598.46 | 0.00 |
| May | 0.00 | 0.00 | 0.506206E+10 | 0.366145E+10 | 3281.26 | 25-MAY-14:10 | 2549.59 | 0.00 |
| June | 0.00 | 0.00 | 0.517614E+10 | 0.376387E+10 | 3521.29 | 28-JUN-15:10 | 2678.50 | 0.00 |
| July | 0.00 | 0.00 | 0.585023E+10 | 0.402027E+10 | 3771.67 | 22-JUL-16:10 | 2961.12 | 0.00 |
| August | 0.00 | 0.00 | 0.571190E+10 | 0.399366E+10 | 3682.19 | 03-AUG-16:02 | 2991.06 | 0.00 |
| September | 0.00 | 0.00 | 0.518016E+10 | 0.356958E+10 | 4463.83 | 10-SEP-13:20 | 3365.40 | 0.00 |
| October | 0.00 | 0.00 | 0.460512E+10 | 0.338211E+10 | 4699.47 | 08-OCT-14:00 | 3486.14 | 0.00 |
| November | 0.00 | 0.00 | 0.207202E+10 | 0.167494E+10 | 3836.44 | 07-NOV-13:30 | 2880.26 | 0.00 |
| December | 0.00 | 0.00 | 0.142478E+10 | 0.114468E+10 | 3720.93 | 16-DEC-13:30 | 3035.97 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.407846E+11 | 0.297694E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.844679E+09 | 0.692042E+09 | 2929.42 | 2329.35 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.585023E+10 | 0.402027E+10 | 4699.47 | 3486.14 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 50137083.08 | 0.40 | 165.96 | 19-JAN-15:30 | 1.00 |
| February | 59007607.91 | 0.51 | 150.55 | 27-FEB-16:10 | 1.01 |
| March | 63613382.04 | 0.52 | 139.82 | 06-MAR-16:10 | 1.01 |
| April | 0.123989E+09 | 0.84 | 186.75 | 29-APR-16:03 | 0.99 |
| May | 0.285745E+09 | 1.02 | 182.82 | 28-MAY-16:10 | 1.00 |
| June | 0.302683E+09 | 1.02 | 199.92 | 17-JUN-16:30 | 0.99 |
| July | 0.357204E+09 | 1.01 | 222.46 | 22-JUL-16:30 | 0.98 |
| August | 0.377262E+09 | 1.01 | 229.95 | 03-AUG-16:02 | 0.98 |
| September | 0.349688E+09 | 1.01 | 255.23 | 09-SEP-17:00 | 0.97 |
| October | 0.318892E+09 | 0.99 | 255.63 | 08-OCT-15:30 | 0.96 |
| November | 0.161614E+09 | 0.91 | 204.46 | 02-NOV-15:10 | 0.99 |
| December | 0.101396E+09 | 0.59 | 182.60 | 16-DEC-13:30 | 1.00 |
| Annual Sum or Average | 0.255123E+10 | 0.82 | |||
| Minimum of Months | 50137083.08 | 0.40 | 139.82 | 0.96 | |
| Maximum of Months | 0.377262E+09 | 1.02 | 255.63 | 1.01 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 25246954.72 | 0.39 | 98.23 | 19-JAN-16:10 | 1.03 |
| February | 31659064.31 | 0.41 | 98.09 | 27-FEB-17:05 | 1.03 |
| March | 42111998.39 | 0.46 | 104.72 | 29-MAR-16:03 | 1.02 |
| April | 0.104291E+09 | 0.78 | 170.17 | 29-APR-16:03 | 1.00 |
| May | 0.282917E+09 | 1.02 | 179.72 | 28-MAY-17:10 | 0.99 |
| June | 0.306704E+09 | 1.02 | 204.18 | 28-JUN-17:30 | 0.98 |
| July | 0.357042E+09 | 1.01 | 214.81 | 22-JUL-16:30 | 0.98 |
| August | 0.365511E+09 | 1.01 | 225.83 | 03-AUG-16:13 | 0.97 |
| September | 0.323008E+09 | 1.01 | 237.79 | 09-SEP-17:00 | 0.97 |
| October | 0.265104E+09 | 0.96 | 215.02 | 08-OCT-16:03 | 0.98 |
| November | 93398217.97 | 0.68 | 157.60 | 02-NOV-16:03 | 1.00 |
| December | 55559587.66 | 0.42 | 128.52 | 13-DEC-15:10 | 1.01 |
| Annual Sum or Average | 0.225255E+10 | 0.77 | |||
| Minimum of Months | 25246954.72 | 0.39 | 98.09 | 0.97 | |
| Maximum of Months | 0.365511E+09 | 1.02 | 237.79 | 1.03 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.117700E+10 | 0.91 | 439.44 | 01-JAN-00:10 | 0.91 |
| February | 0.106310E+10 | 0.91 | 439.44 | 01-FEB-00:10 | 0.90 |
| March | 0.117700E+10 | 0.91 | 439.44 | 01-MAR-00:10 | 0.91 |
| April | 0.113903E+10 | 0.91 | 439.44 | 01-APR-00:10 | 0.90 |
| May | 0.117700E+10 | 0.90 | 439.44 | 01-MAY-00:10 | 0.91 |
| June | 0.113903E+10 | 0.90 | 439.44 | 01-JUN-00:10 | 0.90 |
| July | 0.117700E+10 | 0.90 | 439.44 | 01-JUL-00:10 | 0.90 |
| August | 0.117700E+10 | 0.90 | 439.44 | 01-AUG-00:10 | 0.90 |
| September | 0.113903E+10 | 0.90 | 439.44 | 01-SEP-00:10 | 0.90 |
| October | 0.117700E+10 | 0.91 | 439.44 | 01-OCT-00:10 | 0.90 |
| November | 0.113903E+10 | 0.91 | 439.44 | 01-NOV-00:10 | 0.90 |
| December | 0.117700E+10 | 0.91 | 439.44 | 01-DEC-00:10 | 0.91 |
| Annual Sum or Average | 0.138582E+11 | 0.91 | |||
| Minimum of Months | 0.106310E+10 | 0.90 | 439.44 | 0.90 | |
| Maximum of Months | 0.117700E+10 | 0.91 | 439.44 | 0.91 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 23520406.83 | 0.37 | 88.08 | 19-JAN-12:00 | 1.03 |
| February | 28676294.67 | 0.41 | 85.90 | 02-FEB-13:00 | 1.03 |
| March | 42857867.51 | 0.45 | 107.43 | 30-MAR-13:00 | 1.02 |
| April | 0.102304E+09 | 0.78 | 148.06 | 29-APR-16:03 | 1.00 |
| May | 0.283977E+09 | 1.02 | 162.25 | 26-MAY-11:00 | 0.99 |
| June | 0.305053E+09 | 1.01 | 181.48 | 28-JUN-17:30 | 0.99 |
| July | 0.356653E+09 | 1.01 | 203.70 | 19-JUL-13:00 | 0.98 |
| August | 0.360095E+09 | 1.01 | 206.05 | 03-AUG-16:02 | 0.98 |
| September | 0.317161E+09 | 1.01 | 214.80 | 10-SEP-12:00 | 0.97 |
| October | 0.259200E+09 | 0.96 | 197.63 | 08-OCT-14:00 | 0.98 |
| November | 91202934.61 | 0.69 | 139.29 | 02-NOV-15:10 | 1.00 |
| December | 51925051.10 | 0.41 | 115.38 | 16-DEC-13:00 | 1.02 |
| Annual Sum or Average | 0.222263E+10 | 0.76 | |||
| Minimum of Months | 23520406.83 | 0.37 | 85.90 | 0.97 | |
| Maximum of Months | 0.360095E+09 | 1.02 | 214.80 | 1.03 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 17412075.58 | 0.27 | 70.54 | 02-JAN-17:10 | 1.04 |
| February | 23906591.99 | 0.37 | 73.68 | 02-FEB-13:00 | 1.03 |
| March | 37675470.16 | 0.45 | 89.30 | 30-MAR-13:00 | 1.02 |
| April | 96511226.79 | 0.85 | 124.48 | 29-APR-16:03 | 1.00 |
| May | 0.249261E+09 | 1.02 | 138.97 | 25-MAY-17:05 | 1.00 |
| June | 0.266284E+09 | 1.01 | 155.47 | 28-JUN-17:40 | 0.99 |
| July | 0.307422E+09 | 1.01 | 166.82 | 22-JUL-16:40 | 0.98 |
| August | 0.307162E+09 | 1.01 | 169.02 | 03-AUG-16:02 | 0.98 |
| September | 0.273302E+09 | 1.01 | 179.75 | 09-SEP-17:10 | 0.98 |
| October | 0.223791E+09 | 0.98 | 160.43 | 08-OCT-16:03 | 0.99 |
| November | 84842323.39 | 0.75 | 118.88 | 02-NOV-16:03 | 1.01 |
| December | 47797386.38 | 0.39 | 98.83 | 13-DEC-14:00 | 1.02 |
| Annual Sum or Average | 0.193537E+10 | 0.76 | |||
| Minimum of Months | 17412075.58 | 0.27 | 70.54 | 0.98 | |
| Maximum of Months | 0.307422E+09 | 1.02 | 179.75 | 1.04 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 17334307.95 | 0.27 | 70.39 | 02-JAN-17:10 | 1.04 |
| February | 23753890.84 | 0.37 | 73.65 | 02-FEB-13:00 | 1.03 |
| March | 37750417.25 | 0.45 | 89.65 | 30-MAR-13:00 | 1.02 |
| April | 96580196.17 | 0.85 | 124.23 | 29-APR-16:03 | 1.00 |
| May | 0.249457E+09 | 1.02 | 138.76 | 25-MAY-17:05 | 1.00 |
| June | 0.266373E+09 | 1.01 | 155.18 | 28-JUN-17:30 | 0.99 |
| July | 0.307597E+09 | 1.01 | 166.71 | 22-JUL-16:30 | 0.98 |
| August | 0.307131E+09 | 1.01 | 168.84 | 03-AUG-16:02 | 0.98 |
| September | 0.273226E+09 | 1.01 | 179.35 | 09-SEP-17:10 | 0.98 |
| October | 0.223694E+09 | 0.98 | 160.09 | 08-OCT-16:03 | 0.99 |
| November | 84905467.30 | 0.75 | 118.62 | 02-NOV-16:03 | 1.01 |
| December | 47638637.11 | 0.39 | 98.65 | 13-DEC-14:00 | 1.02 |
| Annual Sum or Average | 0.193544E+10 | 0.76 | |||
| Minimum of Months | 17334307.95 | 0.27 | 70.39 | 0.98 | |
| Maximum of Months | 0.307597E+09 | 1.02 | 179.35 | 1.04 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 56205462.24 | 0.52 | 140.00 | 01-JAN-14:00 | 1.01 |
| February | 60068348.47 | 0.56 | 127.21 | 02-FEB-13:00 | 1.01 |
| March | 63746455.19 | 0.56 | 114.38 | 06-MAR-13:00 | 1.01 |
| April | 0.118366E+09 | 0.92 | 140.87 | 29-APR-16:03 | 1.00 |
| May | 0.253244E+09 | 1.02 | 139.66 | 07-MAY-17:10 | 1.00 |
| June | 0.263345E+09 | 1.02 | 151.58 | 17-JUN-16:40 | 1.00 |
| July | 0.308807E+09 | 1.01 | 175.02 | 22-JUL-16:10 | 0.98 |
| August | 0.320043E+09 | 1.01 | 173.30 | 03-AUG-16:02 | 0.99 |
| September | 0.301194E+09 | 1.01 | 202.21 | 10-SEP-13:40 | 0.97 |
| October | 0.279052E+09 | 1.01 | 206.64 | 08-OCT-14:00 | 0.97 |
| November | 0.157870E+09 | 0.98 | 170.98 | 07-NOV-13:30 | 0.99 |
| December | 0.102720E+09 | 0.68 | 162.86 | 16-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.228466E+10 | 0.86 | |||
| Minimum of Months | 56205462.24 | 0.52 | 114.38 | 0.97 | |
| Maximum of Months | 0.320043E+09 | 1.02 | 206.64 | 1.01 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62047499.85 | 0.55 | 150.59 | 01-JAN-14:00 | 1.00 |
| February | 64639936.44 | 0.58 | 130.60 | 02-FEB-13:00 | 1.01 |
| March | 69998075.22 | 0.58 | 118.65 | 06-MAR-13:00 | 1.01 |
| April | 0.129318E+09 | 0.94 | 148.88 | 29-APR-16:03 | 1.00 |
| May | 0.274003E+09 | 1.02 | 149.87 | 07-MAY-17:20 | 1.00 |
| June | 0.284316E+09 | 1.02 | 160.65 | 17-JUN-16:40 | 0.99 |
| July | 0.332981E+09 | 1.01 | 184.90 | 22-JUL-16:10 | 0.98 |
| August | 0.343225E+09 | 1.01 | 179.58 | 27-AUG-16:10 | 0.98 |
| September | 0.323509E+09 | 1.01 | 213.97 | 10-SEP-13:50 | 0.97 |
| October | 0.300180E+09 | 1.01 | 218.23 | 08-OCT-14:00 | 0.96 |
| November | 0.170476E+09 | 1.00 | 177.34 | 07-NOV-13:40 | 0.98 |
| December | 0.110927E+09 | 0.70 | 170.67 | 16-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.246562E+10 | 0.87 | |||
| Minimum of Months | 62047499.85 | 0.55 | 118.65 | 0.96 | |
| Maximum of Months | 0.343225E+09 | 1.02 | 218.23 | 1.01 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.63 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.121849E+09 | 0.42 | 406.92 | 19-JAN-15:30 | 1.00 |
| February | 0.177105E+09 | 0.60 | 376.97 | 27-FEB-16:10 | 1.00 |
| March | 0.207631E+09 | 0.63 | 373.14 | 06-MAR-16:10 | 1.00 |
| April | 0.370915E+09 | 0.94 | 471.06 | 29-APR-16:03 | 0.98 |
| May | 0.690872E+09 | 1.02 | 442.76 | 28-MAY-16:30 | 0.99 |
| June | 0.701483E+09 | 1.02 | 468.08 | 17-JUN-16:30 | 0.98 |
| July | 0.779757E+09 | 1.01 | 494.70 | 22-JUL-16:30 | 0.98 |
| August | 0.769955E+09 | 1.01 | 504.24 | 03-AUG-16:02 | 0.98 |
| September | 0.704893E+09 | 1.02 | 558.78 | 09-SEP-17:00 | 0.97 |
| October | 0.638840E+09 | 0.96 | 569.59 | 08-OCT-15:30 | 0.96 |
| November | 0.324191E+09 | 0.83 | 463.50 | 02-NOV-15:10 | 0.99 |
| December | 0.214895E+09 | 0.58 | 416.80 | 16-DEC-13:30 | 0.99 |
| Annual Sum or Average | 0.570239E+10 | 0.84 | |||
| Minimum of Months | 0.121849E+09 | 0.42 | 373.14 | 0.96 | |
| Maximum of Months | 0.779757E+09 | 1.02 | 569.59 | 1.00 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.63 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 72839198.79 | 0.45 | 246.97 | 19-JAN-16:10 | 1.02 |
| February | 0.101996E+09 | 0.50 | 255.86 | 27-FEB-17:10 | 1.02 |
| March | 0.150747E+09 | 0.54 | 284.38 | 26-MAR-16:10 | 1.02 |
| April | 0.324951E+09 | 0.91 | 431.31 | 29-APR-16:03 | 0.99 |
| May | 0.682633E+09 | 1.02 | 433.12 | 28-MAY-17:10 | 0.99 |
| June | 0.707148E+09 | 1.02 | 479.60 | 28-JUN-17:30 | 0.98 |
| July | 0.776714E+09 | 1.01 | 475.09 | 22-JUL-16:30 | 0.98 |
| August | 0.742659E+09 | 1.01 | 494.55 | 03-AUG-16:13 | 0.98 |
| September | 0.646184E+09 | 1.02 | 517.02 | 09-SEP-17:00 | 0.97 |
| October | 0.522354E+09 | 0.93 | 467.95 | 08-OCT-16:03 | 0.98 |
| November | 0.180694E+09 | 0.63 | 343.86 | 02-NOV-16:03 | 1.00 |
| December | 0.120468E+09 | 0.46 | 284.74 | 13-DEC-15:10 | 1.02 |
| Annual Sum or Average | 0.502939E+10 | 0.79 | |||
| Minimum of Months | 72839198.79 | 0.45 | 246.97 | 0.97 | |
| Maximum of Months | 0.776714E+09 | 1.02 | 517.02 | 1.02 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.114627E+09 | 0.41 | 377.16 | 19-JAN-14:00 | 0.99 |
| February | 0.168647E+09 | 0.60 | 353.98 | 02-FEB-13:00 | 1.00 |
| March | 0.208064E+09 | 0.63 | 350.24 | 07-MAR-11:30 | 1.00 |
| April | 0.362984E+09 | 0.95 | 407.30 | 29-APR-16:03 | 0.99 |
| May | 0.689143E+09 | 1.02 | 396.54 | 25-MAY-14:00 | 0.99 |
| June | 0.695001E+09 | 1.01 | 414.35 | 28-JUN-15:10 | 0.99 |
| July | 0.776264E+09 | 1.01 | 468.76 | 19-JUL-13:00 | 0.98 |
| August | 0.756202E+09 | 1.01 | 449.13 | 03-AUG-16:02 | 0.98 |
| September | 0.689837E+09 | 1.01 | 520.47 | 10-SEP-12:00 | 0.97 |
| October | 0.622333E+09 | 0.96 | 533.96 | 08-OCT-14:00 | 0.96 |
| November | 0.317466E+09 | 0.85 | 435.55 | 07-NOV-13:30 | 0.98 |
| December | 0.201957E+09 | 0.58 | 416.22 | 16-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.560252E+10 | 0.84 | |||
| Minimum of Months | 0.114627E+09 | 0.41 | 350.24 | 0.96 | |
| Maximum of Months | 0.776264E+09 | 1.02 | 533.96 | 1.00 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.63 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 67901190.14 | 0.44 | 218.72 | 19-JAN-12:00 | 1.02 |
| February | 94660133.61 | 0.49 | 230.08 | 24-FEB-13:00 | 1.02 |
| March | 0.151394E+09 | 0.55 | 277.19 | 28-MAR-16:10 | 1.01 |
| April | 0.317787E+09 | 0.92 | 368.92 | 29-APR-16:03 | 0.99 |
| May | 0.680991E+09 | 1.02 | 389.68 | 25-MAY-14:00 | 0.99 |
| June | 0.700321E+09 | 1.01 | 418.63 | 28-JUN-18:00 | 0.98 |
| July | 0.772975E+09 | 1.01 | 464.59 | 19-JUL-13:00 | 0.97 |
| August | 0.729553E+09 | 1.01 | 439.38 | 03-AUG-16:02 | 0.98 |
| September | 0.632650E+09 | 1.02 | 456.04 | 10-SEP-10:30 | 0.97 |
| October | 0.508734E+09 | 0.92 | 420.21 | 08-OCT-14:00 | 0.98 |
| November | 0.175388E+09 | 0.63 | 295.64 | 02-NOV-15:10 | 1.01 |
| December | 0.112766E+09 | 0.45 | 248.20 | 16-DEC-13:00 | 1.02 |
| Annual Sum or Average | 0.494512E+10 | 0.79 | |||
| Minimum of Months | 67901190.14 | 0.44 | 218.72 | 0.97 | |
| Maximum of Months | 0.772975E+09 | 1.02 | 464.59 | 1.02 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 51974413.40 | 0.31 | 170.23 | 31-JAN-16:10 | 1.03 |
| February | 82504523.32 | 0.49 | 183.49 | 24-FEB-13:00 | 1.03 |
| March | 0.130386E+09 | 0.55 | 226.60 | 28-MAR-16:10 | 1.02 |
| April | 0.277331E+09 | 0.96 | 296.01 | 29-APR-16:03 | 1.00 |
| May | 0.570717E+09 | 1.02 | 315.78 | 25-MAY-17:05 | 1.00 |
| June | 0.588269E+09 | 1.02 | 347.07 | 28-JUN-18:00 | 0.99 |
| July | 0.649449E+09 | 1.01 | 362.99 | 03-JUL-16:40 | 0.98 |
| August | 0.616126E+09 | 1.01 | 353.66 | 03-AUG-16:02 | 0.99 |
| September | 0.543201E+09 | 1.02 | 372.82 | 09-SEP-17:10 | 0.98 |
| October | 0.438843E+09 | 0.96 | 335.27 | 08-OCT-16:03 | 0.99 |
| November | 0.168681E+09 | 0.71 | 247.64 | 02-NOV-16:02 | 1.01 |
| December | 0.101593E+09 | 0.41 | 210.24 | 13-DEC-14:00 | 1.02 |
| Annual Sum or Average | 0.421908E+10 | 0.79 | |||
| Minimum of Months | 51974413.40 | 0.31 | 170.23 | 0.98 | |
| Maximum of Months | 0.649449E+09 | 1.02 | 372.82 | 1.03 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 51826988.13 | 0.31 | 169.53 | 31-JAN-16:10 | 1.03 |
| February | 82269470.34 | 0.48 | 184.11 | 24-FEB-13:00 | 1.03 |
| March | 0.130588E+09 | 0.56 | 226.90 | 28-MAR-16:10 | 1.02 |
| April | 0.277399E+09 | 0.96 | 295.42 | 29-APR-16:03 | 1.00 |
| May | 0.570999E+09 | 1.02 | 315.18 | 25-MAY-17:05 | 1.00 |
| June | 0.588378E+09 | 1.02 | 346.24 | 28-JUN-18:00 | 0.99 |
| July | 0.649708E+09 | 1.01 | 362.58 | 03-JUL-16:40 | 0.98 |
| August | 0.616041E+09 | 1.01 | 353.20 | 03-AUG-16:02 | 0.99 |
| September | 0.543040E+09 | 1.02 | 371.81 | 09-SEP-17:10 | 0.98 |
| October | 0.438633E+09 | 0.96 | 334.45 | 08-OCT-16:03 | 0.99 |
| November | 0.168863E+09 | 0.71 | 247.05 | 02-NOV-16:02 | 1.01 |
| December | 0.101327E+09 | 0.41 | 209.91 | 13-DEC-14:00 | 1.02 |
| Annual Sum or Average | 0.421907E+10 | 0.79 | |||
| Minimum of Months | 51826988.13 | 0.31 | 169.53 | 0.98 | |
| Maximum of Months | 0.649708E+09 | 1.02 | 371.81 | 1.03 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.136184E+09 | 0.55 | 333.79 | 19-JAN-14:00 | 1.00 |
| February | 0.175121E+09 | 0.70 | 312.71 | 02-FEB-13:30 | 1.00 |
| March | 0.194810E+09 | 0.69 | 287.57 | 06-MAR-13:00 | 1.01 |
| April | 0.324029E+09 | 1.00 | 334.22 | 29-APR-16:03 | 1.00 |
| May | 0.578985E+09 | 1.02 | 316.23 | 28-MAY-16:10 | 1.00 |
| June | 0.582632E+09 | 1.02 | 333.81 | 17-JUN-16:15 | 1.00 |
| July | 0.652675E+09 | 1.01 | 372.07 | 22-JUL-16:10 | 0.99 |
| August | 0.643370E+09 | 1.01 | 363.29 | 03-AUG-16:02 | 0.99 |
| September | 0.601690E+09 | 1.02 | 425.30 | 10-SEP-13:30 | 0.98 |
| October | 0.556008E+09 | 0.99 | 447.15 | 08-OCT-14:00 | 0.97 |
| November | 0.321703E+09 | 0.94 | 375.18 | 07-NOV-13:30 | 0.99 |
| December | 0.217763E+09 | 0.66 | 368.01 | 16-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.498497E+10 | 0.88 | |||
| Minimum of Months | 0.136184E+09 | 0.55 | 287.57 | 0.97 | |
| Maximum of Months | 0.652675E+09 | 1.02 | 447.15 | 1.01 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.63 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.136359E+09 | 0.55 | 334.13 | 19-JAN-14:00 | 1.00 |
| February | 0.175061E+09 | 0.70 | 312.83 | 02-FEB-13:30 | 1.00 |
| March | 0.195147E+09 | 0.69 | 288.36 | 06-MAR-13:00 | 1.01 |
| April | 0.324039E+09 | 1.00 | 333.60 | 29-APR-16:03 | 1.00 |
| May | 0.579270E+09 | 1.02 | 315.78 | 28-MAY-16:10 | 1.00 |
| June | 0.582754E+09 | 1.02 | 333.05 | 17-JUN-16:15 | 1.00 |
| July | 0.652941E+09 | 1.01 | 371.86 | 22-JUL-16:10 | 0.99 |
| August | 0.643269E+09 | 1.01 | 362.83 | 03-AUG-16:02 | 0.99 |
| September | 0.601496E+09 | 1.02 | 425.68 | 10-SEP-13:30 | 0.97 |
| October | 0.555746E+09 | 0.99 | 447.01 | 08-OCT-14:00 | 0.97 |
| November | 0.321735E+09 | 0.94 | 375.49 | 07-NOV-13:30 | 0.99 |
| December | 0.217401E+09 | 0.66 | 368.27 | 16-DEC-13:00 | 0.99 |
| Annual Sum or Average | 0.498522E+10 | 0.88 | |||
| Minimum of Months | 0.136359E+09 | 0.55 | 288.36 | 0.97 | |
| Maximum of Months | 0.652941E+09 | 1.02 | 447.01 | 1.01 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.62 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.62 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.62 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.62 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.62 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.63 | 40.01 | 01-JAN-00:10 | 0.63 |
| February | 96801429.15 | 0.63 | 40.01 | 01-FEB-00:10 | 0.62 |
| March | 0.107173E+09 | 0.63 | 40.01 | 01-MAR-00:10 | 0.62 |
| April | 0.103716E+09 | 0.63 | 40.01 | 01-APR-00:10 | 0.62 |
| May | 0.107173E+09 | 0.62 | 40.01 | 01-MAY-00:10 | 0.63 |
| June | 0.103716E+09 | 0.62 | 40.01 | 01-JUN-00:10 | 0.62 |
| July | 0.107173E+09 | 0.62 | 40.01 | 01-JUL-00:10 | 0.62 |
| August | 0.107173E+09 | 0.62 | 40.01 | 01-AUG-00:10 | 0.62 |
| September | 0.103716E+09 | 0.62 | 40.01 | 01-SEP-00:10 | 0.62 |
| October | 0.107173E+09 | 0.63 | 40.01 | 01-OCT-00:10 | 0.62 |
| November | 0.103716E+09 | 0.63 | 40.01 | 01-NOV-00:10 | 0.62 |
| December | 0.107173E+09 | 0.63 | 40.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.126188E+10 | 0.63 | |||
| Minimum of Months | 96801429.15 | 0.62 | 40.01 | 0.62 | |
| Maximum of Months | 0.107173E+09 | 0.63 | 40.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 90682085.09 | 0.59 | 256.76 | 19-JAN-15:30 | 0.99 |
| February | 0.101216E+09 | 0.56 | 239.93 | 27-FEB-16:10 | 0.99 |
| March | 0.118656E+09 | 0.63 | 237.33 | 06-MAR-16:10 | 0.99 |
| April | 0.184159E+09 | 0.77 | 307.75 | 29-APR-16:03 | 0.97 |
| May | 0.385894E+09 | 1.02 | 296.66 | 28-MAY-16:30 | 0.97 |
| June | 0.397390E+09 | 1.02 | 304.86 | 28-JUN-15:30 | 0.97 |
| July | 0.440797E+09 | 1.01 | 325.73 | 22-JUL-16:30 | 0.96 |
| August | 0.432898E+09 | 1.01 | 334.22 | 03-AUG-16:02 | 0.96 |
| September | 0.383622E+09 | 1.02 | 360.41 | 09-SEP-16:50 | 0.95 |
| October | 0.341307E+09 | 0.90 | 367.97 | 08-OCT-15:30 | 0.95 |
| November | 0.148907E+09 | 0.68 | 300.46 | 02-NOV-15:10 | 0.97 |
| December | 0.122994E+09 | 0.67 | 267.98 | 15-DEC-15:10 | 0.98 |
| Annual Sum or Average | 0.314852E+10 | 0.83 | |||
| Minimum of Months | 90682085.09 | 0.56 | 237.33 | 0.95 | |
| Maximum of Months | 0.440797E+09 | 1.02 | 367.97 | 0.99 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 76659949.39 | 0.62 | 161.45 | 31-JAN-16:10 | 1.01 |
| February | 71888332.30 | 0.56 | 160.87 | 27-FEB-16:20 | 1.02 |
| March | 94230850.89 | 0.61 | 189.07 | 26-MAR-16:10 | 1.01 |
| April | 0.161747E+09 | 0.75 | 283.45 | 29-APR-16:03 | 0.97 |
| May | 0.382765E+09 | 1.02 | 290.41 | 28-MAY-16:30 | 0.97 |
| June | 0.401399E+09 | 1.02 | 310.69 | 28-JUN-17:30 | 0.97 |
| July | 0.440546E+09 | 1.01 | 314.18 | 18-JUL-16:02 | 0.96 |
| August | 0.419137E+09 | 1.01 | 326.94 | 03-AUG-16:13 | 0.96 |
| September | 0.353285E+09 | 1.02 | 334.74 | 09-SEP-17:00 | 0.96 |
| October | 0.282159E+09 | 0.88 | 302.06 | 08-OCT-15:40 | 0.97 |
| November | 88582224.61 | 0.59 | 220.06 | 02-NOV-15:20 | 0.99 |
| December | 85497717.72 | 0.64 | 181.42 | 13-DEC-15:30 | 1.01 |
| Annual Sum or Average | 0.285790E+10 | 0.81 | |||
| Minimum of Months | 71888332.30 | 0.56 | 160.87 | 0.96 | |
| Maximum of Months | 0.440546E+09 | 1.02 | 334.74 | 1.02 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 84877442.37 | 0.59 | 239.31 | 19-JAN-13:40 | 0.98 |
| February | 95518617.39 | 0.56 | 218.76 | 02-FEB-13:30 | 0.99 |
| March | 0.117003E+09 | 0.62 | 221.41 | 07-MAR-11:40 | 0.99 |
| April | 0.178412E+09 | 0.77 | 261.48 | 29-APR-16:10 | 0.97 |
| May | 0.382578E+09 | 1.02 | 262.79 | 25-MAY-14:00 | 0.97 |
| June | 0.391544E+09 | 1.01 | 274.77 | 28-JUN-15:10 | 0.97 |
| July | 0.436180E+09 | 1.01 | 308.92 | 19-JUL-13:00 | 0.96 |
| August | 0.422654E+09 | 1.01 | 291.55 | 03-AUG-16:02 | 0.96 |
| September | 0.373430E+09 | 1.01 | 338.30 | 10-SEP-12:50 | 0.95 |
| October | 0.330194E+09 | 0.90 | 343.40 | 08-OCT-14:00 | 0.94 |
| November | 0.143539E+09 | 0.68 | 274.89 | 07-NOV-13:30 | 0.97 |
| December | 0.115293E+09 | 0.66 | 263.46 | 16-DEC-13:00 | 0.97 |
| Annual Sum or Average | 0.307122E+10 | 0.82 | |||
| Minimum of Months | 84877442.37 | 0.56 | 218.76 | 0.94 | |
| Maximum of Months | 0.436180E+09 | 1.02 | 343.40 | 0.99 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 72616080.67 | 0.62 | 131.66 | 19-JAN-12:00 | 1.02 |
| February | 67110263.26 | 0.54 | 139.94 | 05-FEB-07:20 | 0.92 |
| March | 93106137.78 | 0.60 | 172.69 | 28-MAR-15:10 | 1.00 |
| April | 0.156294E+09 | 0.75 | 237.76 | 29-APR-16:03 | 0.98 |
| May | 0.379053E+09 | 1.01 | 257.11 | 25-MAY-14:00 | 0.97 |
| June | 0.394856E+09 | 1.01 | 272.89 | 28-JUN-15:10 | 0.97 |
| July | 0.435326E+09 | 1.01 | 305.43 | 19-JUL-13:00 | 0.95 |
| August | 0.408886E+09 | 1.01 | 284.16 | 03-AUG-16:02 | 0.96 |
| September | 0.343750E+09 | 1.02 | 295.36 | 10-SEP-12:00 | 0.96 |
| October | 0.273216E+09 | 0.87 | 272.13 | 08-OCT-14:00 | 0.96 |
| November | 84485148.57 | 0.57 | 188.45 | 02-NOV-15:10 | 1.00 |
| December | 80580926.84 | 0.64 | 156.75 | 16-DEC-13:00 | 1.01 |
| Annual Sum or Average | 0.278928E+10 | 0.81 | |||
| Minimum of Months | 67110263.26 | 0.54 | 131.66 | 0.92 | |
| Maximum of Months | 0.435326E+09 | 1.02 | 305.43 | 1.02 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 54326043.47 | 0.60 | 111.72 | 31-JAN-16:10 | 1.02 |
| February | 52464648.05 | 0.52 | 109.54 | 24-FEB-14:00 | 1.02 |
| March | 73868699.10 | 0.60 | 141.41 | 28-MAR-16:10 | 1.01 |
| April | 0.134806E+09 | 0.77 | 200.42 | 28-APR-16:10 | 0.99 |
| May | 0.324877E+09 | 1.02 | 209.56 | 25-MAY-16:50 | 0.99 |
| June | 0.339891E+09 | 1.01 | 227.31 | 28-JUN-15:10 | 0.98 |
| July | 0.374243E+09 | 1.01 | 238.41 | 19-JUL-13:00 | 0.97 |
| August | 0.352830E+09 | 1.01 | 238.07 | 03-AUG-16:02 | 0.97 |
| September | 0.300617E+09 | 1.02 | 242.81 | 09-SEP-17:00 | 0.97 |
| October | 0.236575E+09 | 0.88 | 221.82 | 08-OCT-14:00 | 0.98 |
| November | 73652901.26 | 0.56 | 159.93 | 02-NOV-15:10 | 1.00 |
| December | 64951549.21 | 0.61 | 132.54 | 15-DEC-14:00 | 1.01 |
| Annual Sum or Average | 0.238310E+10 | 0.80 | |||
| Minimum of Months | 52464648.05 | 0.52 | 109.54 | 0.97 | |
| Maximum of Months | 0.374243E+09 | 1.02 | 242.81 | 1.02 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 54328493.23 | 0.60 | 110.92 | 31-JAN-16:10 | 1.02 |
| February | 52404354.05 | 0.52 | 110.12 | 24-FEB-14:00 | 1.02 |
| March | 74083767.72 | 0.60 | 141.51 | 28-MAR-16:10 | 1.01 |
| April | 0.134829E+09 | 0.77 | 199.42 | 28-APR-16:10 | 0.99 |
| May | 0.324887E+09 | 1.02 | 209.11 | 25-MAY-14:10 | 0.98 |
| June | 0.339789E+09 | 1.01 | 227.02 | 28-JUN-15:10 | 0.98 |
| July | 0.374196E+09 | 1.01 | 238.80 | 19-JUL-13:00 | 0.97 |
| August | 0.352591E+09 | 1.01 | 237.25 | 03-AUG-16:02 | 0.97 |
| September | 0.300377E+09 | 1.02 | 241.59 | 09-SEP-17:00 | 0.97 |
| October | 0.236363E+09 | 0.88 | 221.64 | 08-OCT-14:00 | 0.98 |
| November | 73716648.62 | 0.56 | 159.54 | 02-NOV-15:10 | 1.00 |
| December | 64916795.02 | 0.61 | 132.31 | 15-DEC-14:00 | 1.01 |
| Annual Sum or Average | 0.238248E+10 | 0.80 | |||
| Minimum of Months | 52404354.05 | 0.52 | 110.12 | 0.97 | |
| Maximum of Months | 0.374196E+09 | 1.02 | 241.59 | 1.02 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 72051475.42 | 0.58 | 215.28 | 19-JAN-14:00 | 0.99 |
| February | 84137579.60 | 0.56 | 195.47 | 02-FEB-13:30 | 0.99 |
| March | 98643731.68 | 0.63 | 187.77 | 06-MAR-14:00 | 1.00 |
| April | 0.158002E+09 | 0.81 | 222.44 | 29-APR-16:03 | 0.98 |
| May | 0.328205E+09 | 1.02 | 216.62 | 28-MAY-16:10 | 0.99 |
| June | 0.336015E+09 | 1.02 | 228.81 | 28-JUN-15:10 | 0.98 |
| July | 0.374718E+09 | 1.01 | 249.83 | 22-JUL-16:10 | 0.97 |
| August | 0.366827E+09 | 1.01 | 245.34 | 03-AUG-16:02 | 0.97 |
| September | 0.331184E+09 | 1.02 | 286.78 | 10-SEP-13:30 | 0.96 |
| October | 0.296484E+09 | 0.91 | 295.14 | 08-OCT-14:00 | 0.95 |
| November | 0.137246E+09 | 0.70 | 244.39 | 02-NOV-14:20 | 0.97 |
| December | 0.105511E+09 | 0.65 | 236.38 | 16-DEC-13:30 | 0.98 |
| Annual Sum or Average | 0.268903E+10 | 0.83 | |||
| Minimum of Months | 72051475.42 | 0.56 | 187.77 | 0.95 | |
| Maximum of Months | 0.374718E+09 | 1.02 | 295.14 | 1.00 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 72158899.97 | 0.58 | 215.60 | 19-JAN-14:00 | 0.99 |
| February | 84152508.91 | 0.56 | 195.75 | 02-FEB-13:30 | 0.99 |
| March | 98926016.76 | 0.63 | 188.30 | 06-MAR-14:00 | 1.00 |
| April | 0.158021E+09 | 0.81 | 221.57 | 29-APR-16:03 | 0.98 |
| May | 0.328232E+09 | 1.02 | 215.93 | 07-MAY-14:00 | 0.99 |
| June | 0.335943E+09 | 1.02 | 228.53 | 28-JUN-15:10 | 0.98 |
| July | 0.374696E+09 | 1.01 | 249.20 | 22-JUL-16:10 | 0.97 |
| August | 0.366589E+09 | 1.01 | 244.54 | 03-AUG-16:02 | 0.97 |
| September | 0.330920E+09 | 1.02 | 287.03 | 10-SEP-13:30 | 0.96 |
| October | 0.296216E+09 | 0.91 | 294.85 | 08-OCT-14:00 | 0.95 |
| November | 0.137334E+09 | 0.70 | 244.33 | 02-NOV-14:10 | 0.97 |
| December | 0.105443E+09 | 0.65 | 236.60 | 16-DEC-13:30 | 0.98 |
| Annual Sum or Average | 0.268863E+10 | 0.83 | |||
| Minimum of Months | 72158899.97 | 0.56 | 188.30 | 0.95 | |
| Maximum of Months | 0.374696E+09 | 1.02 | 294.85 | 1.00 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.62 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.62 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.62 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.62 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.63 | 20.01 | 01-JAN-00:10 | 0.62 |
| February | 48400714.57 | 0.63 | 20.01 | 01-FEB-00:10 | 0.62 |
| March | 53586505.42 | 0.63 | 20.01 | 01-MAR-00:10 | 0.62 |
| April | 51857908.47 | 0.63 | 20.01 | 01-APR-00:10 | 0.62 |
| May | 53586505.42 | 0.62 | 20.01 | 01-MAY-00:10 | 0.63 |
| June | 51857908.47 | 0.62 | 20.01 | 01-JUN-00:10 | 0.62 |
| July | 53586505.42 | 0.62 | 20.01 | 01-JUL-00:10 | 0.62 |
| August | 53586505.42 | 0.62 | 20.01 | 01-AUG-00:10 | 0.62 |
| September | 51857908.47 | 0.62 | 20.01 | 01-SEP-00:10 | 0.62 |
| October | 53586505.42 | 0.63 | 20.01 | 01-OCT-00:10 | 0.62 |
| November | 51857908.47 | 0.63 | 20.01 | 01-NOV-00:10 | 0.62 |
| December | 53586505.42 | 0.63 | 20.01 | 01-DEC-00:10 | 0.63 |
| Annual Sum or Average | 0.630938E+09 | 0.63 | |||
| Minimum of Months | 48400714.57 | 0.62 | 20.01 | 0.62 | |
| Maximum of Months | 53586505.42 | 0.63 | 20.01 | 0.63 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.236469E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.273779E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.294756E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.596010E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.140548E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.149911E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.177699E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.186589E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.171173E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.155191E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.767987E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.480682E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.124608E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.236469E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186589E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 93848619.66 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.124908E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.185421E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.504231E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.139687E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.152471E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.178289E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.181499E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.158762E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.129769E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.448500E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.256274E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.110179E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 93848619.66 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.181499E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.137856E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.130323E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.144846E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.152363E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.196472E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.199751E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.209288E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.222074E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.201500E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.200399E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.161305E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.147265E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.210344E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.130323E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.222074E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 87314870.65 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.113027E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.192553E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.500595E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.141928E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.153527E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.180315E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.181047E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.157830E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.128464E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.443377E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.241218E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.110092E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 87314870.65 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.181047E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 78863296.20 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.108562E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.179826E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.473224E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.124942E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.134462E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.155975E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.154988E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.136445E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.111233E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.413608E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.231596E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.966614E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 78863296.20 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.155975E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 78539490.74 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.107859E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.180276E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.473672E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.125070E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.134540E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.156102E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.155011E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.136441E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.111214E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.414006E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.230859E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.966899E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 78539490.74 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.156102E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.269134E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.288740E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.307526E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.576275E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.126306E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.132323E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.155901E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.160652E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.149581E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.137701E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.760338E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.494341E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.113210E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.269134E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.160652E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.296614E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.310294E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.337219E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.628395E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.136375E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.142547E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.167742E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.171926E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.160353E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.147817E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.819691E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.532995E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.121928E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.296614E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.171926E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.568920E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.820398E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.969492E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.177105E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.338451E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.346124E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.386793E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.380215E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.344580E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.310624E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.153707E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.100664E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.277414E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.568920E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.386793E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.264760E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.433953E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.692044E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.155996E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.335776E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.350336E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.386851E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.368292E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.317225E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.255554E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.866549E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.530679E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.244883E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.264760E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.386851E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.542783E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.791985E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.985509E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.175620E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.342184E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.347619E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.390383E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.378588E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.341849E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.306750E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.152539E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.957888E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.276335E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.542783E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.390383E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.247998E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.406912E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.707294E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.154719E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.339801E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.351994E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.390641E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.367111E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.315121E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.252536E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.853359E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.499515E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.244343E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.247998E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.390641E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.234413E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.384102E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.627392E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.134942E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.284679E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.295677E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.328192E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.309922E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.270343E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.217575E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.819497E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.482860E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209616E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.234413E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.328192E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.233790E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.383092E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.628580E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.135010E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.284896E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.295812E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.328411E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.309964E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.270337E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.217532E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.820576E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.481605E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209673E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.233790E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.328411E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.648172E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.834737E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.933012E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.156505E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.287086E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.291101E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.327855E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.321647E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.297640E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.273399E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.154188E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.104245E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.245526E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.648172E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.327855E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.649148E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.834660E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.934866E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.156551E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.287306E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.291242E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.328078E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.321686E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.297626E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.273346E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.154243E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.104099E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.245604E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.649148E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.328078E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.309661E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.400489E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.493436E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.878312E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.188651E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.195569E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.217964E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.213228E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.187136E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.165657E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.693552E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.494283E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.149518E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.309661E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.217964E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.174190E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.226461E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.364875E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.773685E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.187540E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.197984E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.218332E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.206954E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.172771E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.137362E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.398242E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.274257E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.134211E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.174190E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.218332E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.289947E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.381908E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.495334E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.864347E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.190014E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.195789E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.219190E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.211572E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.185110E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.162862E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.679554E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.465518E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.148220E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.289947E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.219190E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.162002E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.210623E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.368444E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.760040E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.188824E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.198033E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.219418E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.205334E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.170956E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.135252E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.387251E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.255181E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.133217E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.162002E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.219418E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.136623E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.177439E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.304457E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.649360E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.160042E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.168625E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.186568E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.175193E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.147762E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.115952E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.343390E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.229646E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.113823E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.136623E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186568E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.136562E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.177234E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.305615E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.649854E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.160147E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.168679E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.186661E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.175185E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.147737E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.115921E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.343842E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.229322E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.113857E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.136562E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186661E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.279781E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.357257E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.432636E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.757391E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.161194E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.166195E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.186233E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.181556E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.162264E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.144599E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.650584E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.457490E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.129555E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.279781E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186233E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.280310E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.357463E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.434134E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.757904E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.161302E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.166257E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.186332E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.181546E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.162231E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.144554E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.651335E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.457243E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.129606E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.280310E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.186332E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 50137083.08 | 0.755234E+09 | 3521663.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 59007607.91 | 0.869727E+09 | 36132292.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 63613382.04 | 0.929470E+09 | 48164986.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.123989E+09 | 0.187626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.285745E+09 | 0.440769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.302683E+09 | 0.466819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.357204E+09 | 0.558450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.377262E+09 | 0.588930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.349688E+09 | 0.548017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.318892E+09 | 0.495158E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.161614E+09 | 0.243922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101396E+09 | 0.153363E+10 | 5701732.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.255123E+10 | 0.393850E+11 | 93520675.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50137083.08 | 0.755234E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.377262E+09 | 0.588930E+10 | 48164986.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 25246954.72 | 0.278826E+09 | 0.153414E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 31659064.31 | 0.377082E+09 | 0.152834E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 42111998.39 | 0.576802E+09 | 96083133.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.104291E+09 | 0.159063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.282917E+09 | 0.439382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.306704E+09 | 0.476420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.357042E+09 | 0.562124E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.365511E+09 | 0.574492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323008E+09 | 0.509158E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.265104E+09 | 0.414093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93398217.97 | 0.143215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 55559587.66 | 0.816078E+09 | 59336762.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.225255E+10 | 0.348283E+11 | 0.461669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 25246954.72 | 0.278826E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.365511E+09 | 0.574492E+10 | 0.153414E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.117700E+10 | 0.817823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.106310E+10 | 0.985661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117700E+10 | 0.110667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113903E+10 | 0.155402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.117700E+10 | 0.316823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.113903E+10 | 0.344098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.117700E+10 | 0.371697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.117700E+10 | 0.426128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.113903E+10 | 0.366194E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.117700E+10 | 0.341357E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113903E+10 | 0.195543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.117700E+10 | 0.121280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138582E+11 | 0.292954E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.106310E+10 | 0.817823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.117700E+10 | 0.426128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 23520406.83 | 0.259348E+09 | 0.150032E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 28676294.67 | 0.341050E+09 | 0.147542E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 42857867.51 | 0.603868E+09 | 89630486.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.102304E+09 | 0.158650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.283977E+09 | 0.449154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.305053E+09 | 0.482650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.356653E+09 | 0.572107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.360095E+09 | 0.576603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.317161E+09 | 0.509141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.259200E+09 | 0.412384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 91202934.61 | 0.142273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51925051.10 | 0.770815E+09 | 62872151.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.222263E+10 | 0.350047E+11 | 0.450076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23520406.83 | 0.259348E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.360095E+09 | 0.576603E+10 | 0.150032E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 17412075.58 | 0.249983E+09 | 31549648.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23906591.99 | 0.342836E+09 | 43599804.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 37675470.16 | 0.573930E+09 | 21585108.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96511226.79 | 0.150397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.249261E+09 | 0.396078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.266284E+09 | 0.423580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.307422E+09 | 0.495491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.307162E+09 | 0.493718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.273302E+09 | 0.440452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.223791E+09 | 0.356978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 84842323.39 | 0.132838E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 47797386.38 | 0.749357E+09 | 7520594.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193537E+10 | 0.308114E+11 | 0.104255E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17412075.58 | 0.249983E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.307422E+09 | 0.495491E+10 | 43599804.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 17334307.95 | 0.248979E+09 | 31359568.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23753890.84 | 0.340592E+09 | 43555184.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 37750417.25 | 0.575479E+09 | 21363569.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96580196.17 | 0.150548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.249457E+09 | 0.396530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.266373E+09 | 0.423875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.307597E+09 | 0.495954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.307131E+09 | 0.493847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.273226E+09 | 0.440484E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.223694E+09 | 0.356951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 84905467.30 | 0.132971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 47638637.11 | 0.747010E+09 | 7665940.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193544E+10 | 0.308237E+11 | 0.103944E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17334307.95 | 0.248979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.307597E+09 | 0.495954E+10 | 43555184.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 56205462.24 | 0.859598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60068348.47 | 0.926054E+09 | 1227723.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 63746455.19 | 0.981713E+09 | 1787018.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.118366E+09 | 0.182583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.253244E+09 | 0.398890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.263345E+09 | 0.415071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.308807E+09 | 0.493219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.320043E+09 | 0.509887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.301194E+09 | 0.481644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.279052E+09 | 0.441535E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.157870E+09 | 0.242598E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.102720E+09 | 0.158363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.228466E+10 | 0.360052E+11 | 3014741.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56205462.24 | 0.859598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320043E+09 | 0.509887E+10 | 1787018.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 62047499.85 | 0.946748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64639936.44 | 0.995108E+09 | 1134072.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69998075.22 | 0.107655E+10 | 1351522.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129318E+09 | 0.199266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.274003E+09 | 0.431266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.284316E+09 | 0.447781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.332981E+09 | 0.531405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.343225E+09 | 0.546533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323509E+09 | 0.517084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.300180E+09 | 0.474733E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.170476E+09 | 0.261678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.110927E+09 | 0.170819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.246562E+10 | 0.388240E+11 | 2485594.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62047499.85 | 0.946748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.343225E+09 | 0.546533E+10 | 1351522.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.121849E+09 | 0.181324E+10 | 30114220.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.177105E+09 | 0.260590E+10 | 90779352.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.207631E+09 | 0.307050E+10 | 78459196.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.370915E+09 | 0.558693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.690872E+09 | 0.106227E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.701483E+09 | 0.107688E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.779757E+09 | 0.121326E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.769955E+09 | 0.119572E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.704893E+09 | 0.109940E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.638840E+09 | 0.988028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.324191E+09 | 0.487225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.214895E+09 | 0.319784E+10 | 66387868.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.570239E+10 | 0.875023E+11 | 0.265741E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.121849E+09 | 0.181324E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.779757E+09 | 0.121326E+11 | 90779352.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 72839198.79 | 0.782390E+09 | 0.469250E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101996E+09 | 0.134508E+10 | 0.296339E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.150747E+09 | 0.218543E+10 | 0.154149E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.324951E+09 | 0.493133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.682633E+09 | 0.105708E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.707148E+09 | 0.109368E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.776714E+09 | 0.121720E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.742659E+09 | 0.116139E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.646184E+09 | 0.101401E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.522354E+09 | 0.813154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.180694E+09 | 0.276302E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.120468E+09 | 0.166608E+10 | 0.264046E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.502939E+10 | 0.772384E+11 | 0.118378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72839198.79 | 0.782390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.776714E+09 | 0.121720E+11 | 0.469250E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.114627E+09 | 0.173990E+10 | 27373709.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.168647E+09 | 0.252868E+10 | 85948077.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.208064E+09 | 0.314120E+10 | 75129523.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.362984E+09 | 0.557105E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.689143E+09 | 0.108166E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.695001E+09 | 0.108903E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.776264E+09 | 0.123305E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.756202E+09 | 0.119878E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.689837E+09 | 0.109799E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.622333E+09 | 0.982573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.317466E+09 | 0.486250E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.201957E+09 | 0.305942E+10 | 69294007.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.560252E+10 | 0.877336E+11 | 0.257745E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.114627E+09 | 0.173990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.776264E+09 | 0.123305E+11 | 85948077.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 67901190.14 | 0.734534E+09 | 0.451719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 94660133.61 | 0.126598E+10 | 0.285371E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.151394E+09 | 0.225008E+10 | 0.143719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.317787E+09 | 0.491844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.680991E+09 | 0.107767E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.700321E+09 | 0.110687E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.772975E+09 | 0.123808E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.729553E+09 | 0.116579E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.632650E+09 | 0.101397E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.508734E+09 | 0.809135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.175388E+09 | 0.273692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.112766E+09 | 0.157350E+10 | 0.272610E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.494512E+10 | 0.775945E+11 | 0.115342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 67901190.14 | 0.734534E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.772975E+09 | 0.123808E+11 | 0.451719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 51974413.40 | 0.744268E+09 | 92708957.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82504523.32 | 0.122279E+10 | 81577981.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.130386E+09 | 0.200933E+10 | 18692238.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.277331E+09 | 0.428869E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.570717E+09 | 0.901793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.588269E+09 | 0.929303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649449E+09 | 0.103920E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.616126E+09 | 0.982977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.543201E+09 | 0.869388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.438843E+09 | 0.695990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.168681E+09 | 0.262659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101593E+09 | 0.155299E+10 | 58336891.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.421908E+10 | 0.666312E+11 | 0.251316E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51974413.40 | 0.744268E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.649449E+09 | 0.103920E+11 | 92708957.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 51826988.13 | 0.742329E+09 | 92574870.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82269470.34 | 0.121964E+10 | 81475851.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.130588E+09 | 0.201342E+10 | 18440822.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.277399E+09 | 0.429114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.570999E+09 | 0.902590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.588378E+09 | 0.929837E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649708E+09 | 0.104002E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.616041E+09 | 0.983221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.543040E+09 | 0.869461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.438633E+09 | 0.695927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.168863E+09 | 0.263015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101327E+09 | 0.154898E+10 | 58925745.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.421907E+10 | 0.666563E+11 | 0.251417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51826988.13 | 0.742329E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.649708E+09 | 0.104002E+11 | 92574870.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.136184E+09 | 0.206586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.175121E+09 | 0.266920E+10 | 8700438.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194810E+09 | 0.297446E+10 | 984968.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.324029E+09 | 0.495874E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.578985E+09 | 0.905883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.582632E+09 | 0.911071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.652675E+09 | 0.103402E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.643370E+09 | 0.101644E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.601690E+09 | 0.954439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.556008E+09 | 0.873233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.321703E+09 | 0.490704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.217763E+09 | 0.333130E+10 | 500502.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.498497E+10 | 0.778575E+11 | 10185909.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136184E+09 | 0.206586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.652675E+09 | 0.103402E+11 | 8700438.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.136359E+09 | 0.206892E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.175061E+09 | 0.266911E+10 | 8686864.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.195147E+09 | 0.298067E+10 | 960868.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.324039E+09 | 0.496063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.579270E+09 | 0.906682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.582754E+09 | 0.911617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.652941E+09 | 0.103485E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.643269E+09 | 0.101668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.601496E+09 | 0.954506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.555746E+09 | 0.873172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.321735E+09 | 0.490930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.217401E+09 | 0.332698E+10 | 554729.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.498522E+10 | 0.778907E+11 | 10202462.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136359E+09 | 0.206892E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.652941E+09 | 0.103485E+11 | 8686864.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 90682085.09 | 0.888031E+09 | 0.670467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101216E+09 | 0.121507E+10 | 0.436597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118656E+09 | 0.151154E+10 | 0.382379E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.184159E+09 | 0.276583E+10 | 1536175.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.385894E+09 | 0.590152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.397390E+09 | 0.606568E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.440797E+09 | 0.682098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.432898E+09 | 0.669047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.383622E+09 | 0.595804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.341307E+09 | 0.526415E+10 | 6354980.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.148907E+09 | 0.219048E+10 | 66979435.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122994E+09 | 0.149961E+10 | 0.500709E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.314852E+10 | 0.467714E+11 | 0.206502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 90682085.09 | 0.888031E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.440797E+09 | 0.682098E+10 | 0.670467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 76659949.39 | 0.396586E+09 | 0.108382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 71888332.30 | 0.625682E+09 | 0.654938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 94230850.89 | 0.109114E+10 | 0.471458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.161747E+09 | 0.243685E+10 | 5471959.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.382765E+09 | 0.587926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.401399E+09 | 0.615641E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.440546E+09 | 0.684735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.419137E+09 | 0.650341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.353285E+09 | 0.550191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.282159E+09 | 0.435449E+10 | 15905058.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 88582224.61 | 0.124492E+10 | 0.145851E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 85497717.72 | 0.762474E+09 | 0.762140E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.285790E+10 | 0.418005E+11 | 0.313959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 71888332.30 | 0.396586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.440546E+09 | 0.684735E+10 | 0.108382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 84877442.37 | 0.834245E+09 | 0.655371E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95518617.39 | 0.116625E+10 | 0.425378E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117003E+09 | 0.153206E+10 | 0.373458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.178412E+09 | 0.274252E+10 | 1400861.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.382578E+09 | 0.600201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.391544E+09 | 0.613060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.436180E+09 | 0.692590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.422654E+09 | 0.670161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.373430E+09 | 0.594756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.330194E+09 | 0.522590E+10 | 5855505.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143539E+09 | 0.216376E+10 | 63279858.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.115293E+09 | 0.141933E+10 | 0.500960E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.307122E+10 | 0.467918E+11 | 0.202570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 84877442.37 | 0.834245E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.436180E+09 | 0.692590E+10 | 0.655371E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 72616080.67 | 0.363794E+09 | 0.106163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 67110263.26 | 0.581436E+09 | 0.637674E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 93106137.78 | 0.111408E+10 | 0.457321E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.156294E+09 | 0.241196E+10 | 5083107.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.379053E+09 | 0.597966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.394856E+09 | 0.622047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.435326E+09 | 0.695175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.408886E+09 | 0.651532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.343750E+09 | 0.549326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.273216E+09 | 0.432751E+10 | 15741521.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 84485148.57 | 0.122088E+10 | 0.133921E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 80580926.84 | 0.707034E+09 | 0.763017E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.278928E+10 | 0.418871E+11 | 0.307438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 67110263.26 | 0.363794E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.435326E+09 | 0.695175E+10 | 0.106163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 54326043.47 | 0.335161E+09 | 0.703512E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 52464648.05 | 0.506093E+09 | 0.418727E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 73868699.10 | 0.931681E+09 | 0.278389E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134806E+09 | 0.205177E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324877E+09 | 0.503475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.339891E+09 | 0.526519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374243E+09 | 0.587228E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.352830E+09 | 0.552187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.300617E+09 | 0.472040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.236575E+09 | 0.368665E+10 | 2739347.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73652901.26 | 0.108784E+10 | 63480467.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 64951549.21 | 0.668444E+09 | 0.469346E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.238310E+10 | 0.356821E+11 | 0.193619E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52464648.05 | 0.335161E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374243E+09 | 0.587228E+10 | 0.703512E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 54328493.23 | 0.334894E+09 | 0.704485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 52404354.05 | 0.505506E+09 | 0.418938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 74083767.72 | 0.935563E+09 | 0.278739E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134829E+09 | 0.205377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324887E+09 | 0.503966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.339789E+09 | 0.526863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374196E+09 | 0.587720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.352591E+09 | 0.552336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.300377E+09 | 0.472101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.236363E+09 | 0.368678E+10 | 2759253.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73716648.62 | 0.108943E+10 | 63839391.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 64916795.02 | 0.667255E+09 | 0.471118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.238248E+10 | 0.357031E+11 | 0.193988E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52404354.05 | 0.334894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374196E+09 | 0.587720E+10 | 0.704485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 72051475.42 | 0.842986E+09 | 0.348006E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 84137579.60 | 0.111020E+10 | 0.235173E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98643731.68 | 0.134871E+10 | 0.204603E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.158002E+09 | 0.239052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.328205E+09 | 0.505712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.336015E+09 | 0.517262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374718E+09 | 0.584527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366827E+09 | 0.571046E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.331184E+09 | 0.517962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.296484E+09 | 0.460505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137246E+09 | 0.206909E+10 | 13388995.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105511E+09 | 0.142537E+10 | 0.251262E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268903E+10 | 0.407570E+11 | 0.105243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72051475.42 | 0.842986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374718E+09 | 0.584527E+10 | 0.348006E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 72158899.97 | 0.844679E+09 | 0.348755E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 84152508.91 | 0.111105E+10 | 0.235548E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98926016.76 | 0.135377E+10 | 0.205071E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.158021E+09 | 0.239272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.328232E+09 | 0.506206E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.335943E+09 | 0.517614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374696E+09 | 0.585023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366589E+09 | 0.571190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.330920E+09 | 0.518016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.296216E+09 | 0.460512E+10 | 8867.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137334E+09 | 0.207202E+10 | 13520072.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105443E+09 | 0.142478E+10 | 0.252345E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268863E+10 | 0.407846E+11 | 0.105525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72158899.97 | 0.844679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374696E+09 | 0.585023E+10 | 0.348755E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 50137083.08 | 0.00 | 0.00 | 0.00 | 0.186332E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 59007607.91 | 0.00 | 0.00 | 0.00 | 0.214772E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 63613382.04 | 0.00 | 0.00 | 0.00 | 0.231143E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.123989E+09 | 0.00 | 0.00 | 0.00 | 0.472020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.285745E+09 | 0.00 | 0.00 | 0.00 | 0.111974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.302683E+09 | 0.00 | 0.00 | 0.00 | 0.119643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.357204E+09 | 0.00 | 0.00 | 0.00 | 0.141979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.377262E+09 | 0.00 | 0.00 | 0.00 | 0.148862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.349688E+09 | 0.00 | 0.00 | 0.00 | 0.136204E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.318892E+09 | 0.00 | 0.00 | 0.00 | 0.123302E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.161614E+09 | 0.00 | 0.00 | 0.00 | 0.606374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101396E+09 | 0.00 | 0.00 | 0.00 | 0.379286E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.255123E+10 | 0.00 | 0.00 | 0.00 | 0.990957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50137083.08 | 0.00 | 0.00 | 0.00 | 0.186332E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.377262E+09 | 0.00 | 0.00 | 0.00 | 0.148862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 25246954.72 | 0.00 | 0.00 | 0.00 | 68601664.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 31659064.31 | 0.00 | 0.00 | 0.00 | 93248893.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 42111998.39 | 0.00 | 0.00 | 0.00 | 0.143309E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.104291E+09 | 0.00 | 0.00 | 0.00 | 0.399940E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.282917E+09 | 0.00 | 0.00 | 0.00 | 0.111395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.306704E+09 | 0.00 | 0.00 | 0.00 | 0.121800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.357042E+09 | 0.00 | 0.00 | 0.00 | 0.142584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.365511E+09 | 0.00 | 0.00 | 0.00 | 0.144948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323008E+09 | 0.00 | 0.00 | 0.00 | 0.126461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.265104E+09 | 0.00 | 0.00 | 0.00 | 0.103259E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93398217.97 | 0.00 | 0.00 | 0.00 | 0.355102E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 55559587.66 | 0.00 | 0.00 | 0.00 | 0.200715E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.225255E+10 | 0.00 | 0.00 | 0.00 | 0.876539E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 25246954.72 | 0.00 | 0.00 | 0.00 | 68601664.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.365511E+09 | 0.00 | 0.00 | 0.00 | 0.144948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.201565E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.106310E+10 | 0.00 | 0.00 | 0.00 | 0.240132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.271461E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113903E+10 | 0.00 | 0.00 | 0.00 | 0.384597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.787721E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.113903E+10 | 0.00 | 0.00 | 0.00 | 0.858474E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.915880E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.104374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.113903E+10 | 0.00 | 0.00 | 0.00 | 0.875970E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.826986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.113903E+10 | 0.00 | 0.00 | 0.00 | 0.474014E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.295654E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.138582E+11 | 0.00 | 0.00 | 0.00 | 0.717619E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.106310E+10 | 0.00 | 0.00 | 0.00 | 0.201565E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.104374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 23520406.83 | 0.00 | 0.00 | 0.00 | 63794463.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 28676294.67 | 0.00 | 0.00 | 0.00 | 84350372.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 42857867.51 | 0.00 | 0.00 | 0.00 | 0.149695E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.102304E+09 | 0.00 | 0.00 | 0.00 | 0.398291E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.283977E+09 | 0.00 | 0.00 | 0.00 | 0.113530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.305053E+09 | 0.00 | 0.00 | 0.00 | 0.123021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.356653E+09 | 0.00 | 0.00 | 0.00 | 0.144650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.360095E+09 | 0.00 | 0.00 | 0.00 | 0.145038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.317161E+09 | 0.00 | 0.00 | 0.00 | 0.126114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.259200E+09 | 0.00 | 0.00 | 0.00 | 0.102544E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 91202934.61 | 0.00 | 0.00 | 0.00 | 0.352174E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51925051.10 | 0.00 | 0.00 | 0.00 | 0.189293E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.222263E+10 | 0.00 | 0.00 | 0.00 | 0.878657E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23520406.83 | 0.00 | 0.00 | 0.00 | 63794463.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.360095E+09 | 0.00 | 0.00 | 0.00 | 0.145038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 17412075.58 | 0.00 | 0.00 | 0.00 | 61451220.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23906591.99 | 0.00 | 0.00 | 0.00 | 84655894.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 37675470.16 | 0.00 | 0.00 | 0.00 | 0.142150E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96511226.79 | 0.00 | 0.00 | 0.00 | 0.376713E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.249261E+09 | 0.00 | 0.00 | 0.00 | 0.100016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.266284E+09 | 0.00 | 0.00 | 0.00 | 0.107834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.307422E+09 | 0.00 | 0.00 | 0.00 | 0.125233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.307162E+09 | 0.00 | 0.00 | 0.00 | 0.124272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.273302E+09 | 0.00 | 0.00 | 0.00 | 0.109115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.223791E+09 | 0.00 | 0.00 | 0.00 | 0.888543E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 84842323.39 | 0.00 | 0.00 | 0.00 | 0.328765E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 47797386.38 | 0.00 | 0.00 | 0.00 | 0.183799E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193537E+10 | 0.00 | 0.00 | 0.00 | 0.773078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17412075.58 | 0.00 | 0.00 | 0.00 | 61451220.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.307422E+09 | 0.00 | 0.00 | 0.00 | 0.125233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 17334307.95 | 0.00 | 0.00 | 0.00 | 61205182.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23753890.84 | 0.00 | 0.00 | 0.00 | 84105125.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 37750417.25 | 0.00 | 0.00 | 0.00 | 0.142525E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 96580196.17 | 0.00 | 0.00 | 0.00 | 0.377092E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.249457E+09 | 0.00 | 0.00 | 0.00 | 0.100125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.266373E+09 | 0.00 | 0.00 | 0.00 | 0.107903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.307597E+09 | 0.00 | 0.00 | 0.00 | 0.125342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.307131E+09 | 0.00 | 0.00 | 0.00 | 0.124298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.273226E+09 | 0.00 | 0.00 | 0.00 | 0.109118E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.223694E+09 | 0.00 | 0.00 | 0.00 | 0.888441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 84905467.30 | 0.00 | 0.00 | 0.00 | 0.329101E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 47638637.11 | 0.00 | 0.00 | 0.00 | 0.183220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.193544E+10 | 0.00 | 0.00 | 0.00 | 0.773355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 17334307.95 | 0.00 | 0.00 | 0.00 | 61205182.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.307597E+09 | 0.00 | 0.00 | 0.00 | 0.125342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 56205462.24 | 0.00 | 0.00 | 0.00 | 0.212928E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60068348.47 | 0.00 | 0.00 | 0.00 | 0.228671E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 63746455.19 | 0.00 | 0.00 | 0.00 | 0.243780E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.118366E+09 | 0.00 | 0.00 | 0.00 | 0.457909E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.253244E+09 | 0.00 | 0.00 | 0.00 | 0.100982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.263345E+09 | 0.00 | 0.00 | 0.00 | 0.105988E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.308807E+09 | 0.00 | 0.00 | 0.00 | 0.125021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.320043E+09 | 0.00 | 0.00 | 0.00 | 0.128648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.301194E+09 | 0.00 | 0.00 | 0.00 | 0.119462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.279052E+09 | 0.00 | 0.00 | 0.00 | 0.109796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.157870E+09 | 0.00 | 0.00 | 0.00 | 0.602467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.102720E+09 | 0.00 | 0.00 | 0.00 | 0.391622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.228466E+10 | 0.00 | 0.00 | 0.00 | 0.903633E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 56205462.24 | 0.00 | 0.00 | 0.00 | 0.212928E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320043E+09 | 0.00 | 0.00 | 0.00 | 0.128648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 62047499.85 | 0.00 | 0.00 | 0.00 | 0.234566E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64639936.44 | 0.00 | 0.00 | 0.00 | 0.245654E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69998075.22 | 0.00 | 0.00 | 0.00 | 0.267221E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129318E+09 | 0.00 | 0.00 | 0.00 | 0.499077E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.274003E+09 | 0.00 | 0.00 | 0.00 | 0.108974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.284316E+09 | 0.00 | 0.00 | 0.00 | 0.114115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.332981E+09 | 0.00 | 0.00 | 0.00 | 0.134444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.343225E+09 | 0.00 | 0.00 | 0.00 | 0.137603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323509E+09 | 0.00 | 0.00 | 0.00 | 0.128002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.300180E+09 | 0.00 | 0.00 | 0.00 | 0.117799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.170476E+09 | 0.00 | 0.00 | 0.00 | 0.649216E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.110927E+09 | 0.00 | 0.00 | 0.00 | 0.422067E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.246562E+10 | 0.00 | 0.00 | 0.00 | 0.972718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62047499.85 | 0.00 | 0.00 | 0.00 | 0.234566E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.343225E+09 | 0.00 | 0.00 | 0.00 | 0.137603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.121849E+09 | 0.00 | 0.00 | 0.00 | 0.447072E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.177105E+09 | 0.00 | 0.00 | 0.00 | 0.643292E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.207631E+09 | 0.00 | 0.00 | 0.00 | 0.761862E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.370915E+09 | 0.00 | 0.00 | 0.00 | 0.140013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.690872E+09 | 0.00 | 0.00 | 0.00 | 0.269363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.701483E+09 | 0.00 | 0.00 | 0.00 | 0.275976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.779757E+09 | 0.00 | 0.00 | 0.00 | 0.308817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.769955E+09 | 0.00 | 0.00 | 0.00 | 0.303220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.704893E+09 | 0.00 | 0.00 | 0.00 | 0.274090E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.638840E+09 | 0.00 | 0.00 | 0.00 | 0.246740E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.324191E+09 | 0.00 | 0.00 | 0.00 | 0.121288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.214895E+09 | 0.00 | 0.00 | 0.00 | 0.791746E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.570239E+10 | 0.00 | 0.00 | 0.00 | 0.220390E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.121849E+09 | 0.00 | 0.00 | 0.00 | 0.447072E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.779757E+09 | 0.00 | 0.00 | 0.00 | 0.308817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 72839198.79 | 0.00 | 0.00 | 0.00 | 0.191920E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101996E+09 | 0.00 | 0.00 | 0.00 | 0.331957E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.150747E+09 | 0.00 | 0.00 | 0.00 | 0.541297E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.324951E+09 | 0.00 | 0.00 | 0.00 | 0.123500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.682633E+09 | 0.00 | 0.00 | 0.00 | 0.267512E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.707148E+09 | 0.00 | 0.00 | 0.00 | 0.279622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.776714E+09 | 0.00 | 0.00 | 0.00 | 0.309179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.742659E+09 | 0.00 | 0.00 | 0.00 | 0.294026E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.646184E+09 | 0.00 | 0.00 | 0.00 | 0.252606E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.522354E+09 | 0.00 | 0.00 | 0.00 | 0.203318E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.180694E+09 | 0.00 | 0.00 | 0.00 | 0.685855E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.120468E+09 | 0.00 | 0.00 | 0.00 | 0.410211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.502939E+10 | 0.00 | 0.00 | 0.00 | 0.194589E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72839198.79 | 0.00 | 0.00 | 0.00 | 0.191920E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.776714E+09 | 0.00 | 0.00 | 0.00 | 0.309179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.114627E+09 | 0.00 | 0.00 | 0.00 | 0.428157E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.168647E+09 | 0.00 | 0.00 | 0.00 | 0.623337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.208064E+09 | 0.00 | 0.00 | 0.00 | 0.777445E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.362984E+09 | 0.00 | 0.00 | 0.00 | 0.139322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.689143E+09 | 0.00 | 0.00 | 0.00 | 0.273270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.695001E+09 | 0.00 | 0.00 | 0.00 | 0.278119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.776264E+09 | 0.00 | 0.00 | 0.00 | 0.312757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.756202E+09 | 0.00 | 0.00 | 0.00 | 0.302968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.689837E+09 | 0.00 | 0.00 | 0.00 | 0.272865E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.622333E+09 | 0.00 | 0.00 | 0.00 | 0.244516E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.317466E+09 | 0.00 | 0.00 | 0.00 | 0.120793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.201957E+09 | 0.00 | 0.00 | 0.00 | 0.755931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.560252E+10 | 0.00 | 0.00 | 0.00 | 0.220310E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.114627E+09 | 0.00 | 0.00 | 0.00 | 0.428157E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.776264E+09 | 0.00 | 0.00 | 0.00 | 0.312757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 67901190.14 | 0.00 | 0.00 | 0.00 | 0.180097E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 94660133.61 | 0.00 | 0.00 | 0.00 | 0.312252E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.151394E+09 | 0.00 | 0.00 | 0.00 | 0.555900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.317787E+09 | 0.00 | 0.00 | 0.00 | 0.122940E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.680991E+09 | 0.00 | 0.00 | 0.00 | 0.271702E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.700321E+09 | 0.00 | 0.00 | 0.00 | 0.281962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.772975E+09 | 0.00 | 0.00 | 0.00 | 0.313343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.729553E+09 | 0.00 | 0.00 | 0.00 | 0.294156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.632650E+09 | 0.00 | 0.00 | 0.00 | 0.251856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.508734E+09 | 0.00 | 0.00 | 0.00 | 0.201663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.175388E+09 | 0.00 | 0.00 | 0.00 | 0.677971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.112766E+09 | 0.00 | 0.00 | 0.00 | 0.386748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.494512E+10 | 0.00 | 0.00 | 0.00 | 0.194892E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 67901190.14 | 0.00 | 0.00 | 0.00 | 0.180097E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.772975E+09 | 0.00 | 0.00 | 0.00 | 0.313343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 51974413.40 | 0.00 | 0.00 | 0.00 | 0.182439E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82504523.32 | 0.00 | 0.00 | 0.00 | 0.301597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.130386E+09 | 0.00 | 0.00 | 0.00 | 0.497006E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.277331E+09 | 0.00 | 0.00 | 0.00 | 0.107209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.570717E+09 | 0.00 | 0.00 | 0.00 | 0.227607E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.588269E+09 | 0.00 | 0.00 | 0.00 | 0.236850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649449E+09 | 0.00 | 0.00 | 0.00 | 0.263247E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.616126E+09 | 0.00 | 0.00 | 0.00 | 0.248310E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.543201E+09 | 0.00 | 0.00 | 0.00 | 0.216023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.438843E+09 | 0.00 | 0.00 | 0.00 | 0.173690E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.168681E+09 | 0.00 | 0.00 | 0.00 | 0.650816E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101593E+09 | 0.00 | 0.00 | 0.00 | 0.381267E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.421908E+10 | 0.00 | 0.00 | 0.00 | 0.167425E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51974413.40 | 0.00 | 0.00 | 0.00 | 0.182439E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.649449E+09 | 0.00 | 0.00 | 0.00 | 0.263247E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 51826988.13 | 0.00 | 0.00 | 0.00 | 0.181963E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82269470.34 | 0.00 | 0.00 | 0.00 | 0.300823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.130588E+09 | 0.00 | 0.00 | 0.00 | 0.497992E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.277399E+09 | 0.00 | 0.00 | 0.00 | 0.107270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.570999E+09 | 0.00 | 0.00 | 0.00 | 0.227796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.588378E+09 | 0.00 | 0.00 | 0.00 | 0.236974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649708E+09 | 0.00 | 0.00 | 0.00 | 0.263440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.616041E+09 | 0.00 | 0.00 | 0.00 | 0.248360E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.543040E+09 | 0.00 | 0.00 | 0.00 | 0.216033E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.438633E+09 | 0.00 | 0.00 | 0.00 | 0.173668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.168863E+09 | 0.00 | 0.00 | 0.00 | 0.651713E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.101327E+09 | 0.00 | 0.00 | 0.00 | 0.380277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.421907E+10 | 0.00 | 0.00 | 0.00 | 0.167482E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51826988.13 | 0.00 | 0.00 | 0.00 | 0.181963E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.649708E+09 | 0.00 | 0.00 | 0.00 | 0.263440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.136184E+09 | 0.00 | 0.00 | 0.00 | 0.511988E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.175121E+09 | 0.00 | 0.00 | 0.00 | 0.659616E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.194810E+09 | 0.00 | 0.00 | 0.00 | 0.738202E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.324029E+09 | 0.00 | 0.00 | 0.00 | 0.124102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.578985E+09 | 0.00 | 0.00 | 0.00 | 0.229187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.582632E+09 | 0.00 | 0.00 | 0.00 | 0.232838E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.652675E+09 | 0.00 | 0.00 | 0.00 | 0.262587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.643370E+09 | 0.00 | 0.00 | 0.00 | 0.257310E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.601690E+09 | 0.00 | 0.00 | 0.00 | 0.237471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.556008E+09 | 0.00 | 0.00 | 0.00 | 0.217798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.321703E+09 | 0.00 | 0.00 | 0.00 | 0.122018E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.217763E+09 | 0.00 | 0.00 | 0.00 | 0.824690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.498497E+10 | 0.00 | 0.00 | 0.00 | 0.195676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136184E+09 | 0.00 | 0.00 | 0.00 | 0.511988E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.652675E+09 | 0.00 | 0.00 | 0.00 | 0.262587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.136359E+09 | 0.00 | 0.00 | 0.00 | 0.512788E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.175061E+09 | 0.00 | 0.00 | 0.00 | 0.659599E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.195147E+09 | 0.00 | 0.00 | 0.00 | 0.739719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.324039E+09 | 0.00 | 0.00 | 0.00 | 0.124147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.579270E+09 | 0.00 | 0.00 | 0.00 | 0.229379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.582754E+09 | 0.00 | 0.00 | 0.00 | 0.232967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.652941E+09 | 0.00 | 0.00 | 0.00 | 0.262784E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.643269E+09 | 0.00 | 0.00 | 0.00 | 0.257359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.601496E+09 | 0.00 | 0.00 | 0.00 | 0.237476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.555746E+09 | 0.00 | 0.00 | 0.00 | 0.217771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.321735E+09 | 0.00 | 0.00 | 0.00 | 0.122069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.217401E+09 | 0.00 | 0.00 | 0.00 | 0.823593E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.498522E+10 | 0.00 | 0.00 | 0.00 | 0.195752E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136359E+09 | 0.00 | 0.00 | 0.00 | 0.512788E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.652941E+09 | 0.00 | 0.00 | 0.00 | 0.262784E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 90682085.09 | 0.00 | 0.00 | 0.00 | 0.218979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.101216E+09 | 0.00 | 0.00 | 0.00 | 0.299272E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118656E+09 | 0.00 | 0.00 | 0.00 | 0.374780E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.184159E+09 | 0.00 | 0.00 | 0.00 | 0.694154E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.385894E+09 | 0.00 | 0.00 | 0.00 | 0.150062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.397390E+09 | 0.00 | 0.00 | 0.00 | 0.155830E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.440797E+09 | 0.00 | 0.00 | 0.00 | 0.173884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.432898E+09 | 0.00 | 0.00 | 0.00 | 0.169938E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.383622E+09 | 0.00 | 0.00 | 0.00 | 0.148774E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.341307E+09 | 0.00 | 0.00 | 0.00 | 0.131526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.148907E+09 | 0.00 | 0.00 | 0.00 | 0.544645E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122994E+09 | 0.00 | 0.00 | 0.00 | 0.371290E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.314852E+10 | 0.00 | 0.00 | 0.00 | 0.118033E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 90682085.09 | 0.00 | 0.00 | 0.00 | 0.218979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.440797E+09 | 0.00 | 0.00 | 0.00 | 0.173884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 76659949.39 | 0.00 | 0.00 | 0.00 | 97529624.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 71888332.30 | 0.00 | 0.00 | 0.00 | 0.154573E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 94230850.89 | 0.00 | 0.00 | 0.00 | 0.270645E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.161747E+09 | 0.00 | 0.00 | 0.00 | 0.611938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.382765E+09 | 0.00 | 0.00 | 0.00 | 0.149264E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.401399E+09 | 0.00 | 0.00 | 0.00 | 0.157844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.440546E+09 | 0.00 | 0.00 | 0.00 | 0.174278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.419137E+09 | 0.00 | 0.00 | 0.00 | 0.165040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.353285E+09 | 0.00 | 0.00 | 0.00 | 0.137442E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.282159E+09 | 0.00 | 0.00 | 0.00 | 0.109146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 88582224.61 | 0.00 | 0.00 | 0.00 | 0.309659E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 85497717.72 | 0.00 | 0.00 | 0.00 | 0.188759E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.285790E+10 | 0.00 | 0.00 | 0.00 | 0.105632E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 71888332.30 | 0.00 | 0.00 | 0.00 | 97529624.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.440546E+09 | 0.00 | 0.00 | 0.00 | 0.174278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 84877442.37 | 0.00 | 0.00 | 0.00 | 0.205069E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95518617.39 | 0.00 | 0.00 | 0.00 | 0.286390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.117003E+09 | 0.00 | 0.00 | 0.00 | 0.378331E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.178412E+09 | 0.00 | 0.00 | 0.00 | 0.685935E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.382578E+09 | 0.00 | 0.00 | 0.00 | 0.151756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.391544E+09 | 0.00 | 0.00 | 0.00 | 0.156635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.436180E+09 | 0.00 | 0.00 | 0.00 | 0.175572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.422654E+09 | 0.00 | 0.00 | 0.00 | 0.169307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.373430E+09 | 0.00 | 0.00 | 0.00 | 0.147767E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.330194E+09 | 0.00 | 0.00 | 0.00 | 0.129842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143539E+09 | 0.00 | 0.00 | 0.00 | 0.536014E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.115293E+09 | 0.00 | 0.00 | 0.00 | 0.350225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.307122E+10 | 0.00 | 0.00 | 0.00 | 0.117508E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 84877442.37 | 0.00 | 0.00 | 0.00 | 0.205069E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.436180E+09 | 0.00 | 0.00 | 0.00 | 0.175572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 72616080.67 | 0.00 | 0.00 | 0.00 | 89386196.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 67110263.26 | 0.00 | 0.00 | 0.00 | 0.143513E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 93106137.78 | 0.00 | 0.00 | 0.00 | 0.275337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.156294E+09 | 0.00 | 0.00 | 0.00 | 0.603746E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.379053E+09 | 0.00 | 0.00 | 0.00 | 0.150919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.394856E+09 | 0.00 | 0.00 | 0.00 | 0.158547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.435326E+09 | 0.00 | 0.00 | 0.00 | 0.175885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.408886E+09 | 0.00 | 0.00 | 0.00 | 0.164445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.343750E+09 | 0.00 | 0.00 | 0.00 | 0.136581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.273216E+09 | 0.00 | 0.00 | 0.00 | 0.107930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 84485148.57 | 0.00 | 0.00 | 0.00 | 0.302766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 80580926.84 | 0.00 | 0.00 | 0.00 | 0.174601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.278928E+10 | 0.00 | 0.00 | 0.00 | 0.105324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 67110263.26 | 0.00 | 0.00 | 0.00 | 89386196.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.435326E+09 | 0.00 | 0.00 | 0.00 | 0.175885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 54326043.47 | 0.00 | 0.00 | 0.00 | 82296474.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 52464648.05 | 0.00 | 0.00 | 0.00 | 0.124974E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 73868699.10 | 0.00 | 0.00 | 0.00 | 0.230589E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134806E+09 | 0.00 | 0.00 | 0.00 | 0.514553E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324877E+09 | 0.00 | 0.00 | 0.00 | 0.127554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.339891E+09 | 0.00 | 0.00 | 0.00 | 0.134636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374243E+09 | 0.00 | 0.00 | 0.00 | 0.149144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.352830E+09 | 0.00 | 0.00 | 0.00 | 0.139910E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.300617E+09 | 0.00 | 0.00 | 0.00 | 0.117700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.236575E+09 | 0.00 | 0.00 | 0.00 | 0.922944E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73652901.26 | 0.00 | 0.00 | 0.00 | 0.269737E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 64951549.21 | 0.00 | 0.00 | 0.00 | 0.164695E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.238310E+10 | 0.00 | 0.00 | 0.00 | 0.899923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52464648.05 | 0.00 | 0.00 | 0.00 | 82296474.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374243E+09 | 0.00 | 0.00 | 0.00 | 0.149144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 54328493.23 | 0.00 | 0.00 | 0.00 | 82233900.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 52404354.05 | 0.00 | 0.00 | 0.00 | 0.124830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 74083767.72 | 0.00 | 0.00 | 0.00 | 0.231531E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134829E+09 | 0.00 | 0.00 | 0.00 | 0.515026E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324887E+09 | 0.00 | 0.00 | 0.00 | 0.127658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.339789E+09 | 0.00 | 0.00 | 0.00 | 0.134700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374196E+09 | 0.00 | 0.00 | 0.00 | 0.149242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.352591E+09 | 0.00 | 0.00 | 0.00 | 0.139926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.300377E+09 | 0.00 | 0.00 | 0.00 | 0.117699E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.236363E+09 | 0.00 | 0.00 | 0.00 | 0.922850E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 73716648.62 | 0.00 | 0.00 | 0.00 | 0.270126E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 64916795.02 | 0.00 | 0.00 | 0.00 | 0.164405E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.238248E+10 | 0.00 | 0.00 | 0.00 | 0.900325E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52404354.05 | 0.00 | 0.00 | 0.00 | 82233900.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374196E+09 | 0.00 | 0.00 | 0.00 | 0.149242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 72051475.42 | 0.00 | 0.00 | 0.00 | 0.207729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 84137579.60 | 0.00 | 0.00 | 0.00 | 0.273120E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98643731.68 | 0.00 | 0.00 | 0.00 | 0.333992E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.158002E+09 | 0.00 | 0.00 | 0.00 | 0.599388E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.328205E+09 | 0.00 | 0.00 | 0.00 | 0.128373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.336015E+09 | 0.00 | 0.00 | 0.00 | 0.132593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374718E+09 | 0.00 | 0.00 | 0.00 | 0.148761E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366827E+09 | 0.00 | 0.00 | 0.00 | 0.144873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.331184E+09 | 0.00 | 0.00 | 0.00 | 0.129146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.296484E+09 | 0.00 | 0.00 | 0.00 | 0.114951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137246E+09 | 0.00 | 0.00 | 0.00 | 0.513338E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105511E+09 | 0.00 | 0.00 | 0.00 | 0.351979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268903E+10 | 0.00 | 0.00 | 0.00 | 0.102665E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72051475.42 | 0.00 | 0.00 | 0.00 | 0.207729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374718E+09 | 0.00 | 0.00 | 0.00 | 0.148761E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 72158899.97 | 0.00 | 0.00 | 0.00 | 0.208151E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 84152508.91 | 0.00 | 0.00 | 0.00 | 0.273311E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 98926016.76 | 0.00 | 0.00 | 0.00 | 0.335208E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.158021E+09 | 0.00 | 0.00 | 0.00 | 0.599883E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.328232E+09 | 0.00 | 0.00 | 0.00 | 0.128479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.335943E+09 | 0.00 | 0.00 | 0.00 | 0.132663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.374696E+09 | 0.00 | 0.00 | 0.00 | 0.148862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366589E+09 | 0.00 | 0.00 | 0.00 | 0.144887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.330920E+09 | 0.00 | 0.00 | 0.00 | 0.129139E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.296216E+09 | 0.00 | 0.00 | 0.00 | 0.114932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.137334E+09 | 0.00 | 0.00 | 0.00 | 0.514001E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105443E+09 | 0.00 | 0.00 | 0.00 | 0.351799E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268863E+10 | 0.00 | 0.00 | 0.00 | 0.102720E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72158899.97 | 0.00 | 0.00 | 0.00 | 0.208151E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.374696E+09 | 0.00 | 0.00 | 0.00 | 0.148862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.634894E+09 | 49164672.36 | 0.00 | 781165.04 | 0.00 | 0.00 | 0.166002E+09 | 0.00 | 0.35 |
| February | 0.438445E+09 | 69287052.74 | 0.00 | 598738.09 | 7731.08 | 12159131.93 | 0.117731E+09 | 0.00 | 0.35 |
| March | 0.410966E+09 | 0.106454E+09 | 0.00 | 408434.97 | 133873.89 | 22156363.88 | 84651300.64 | 0.00 | 0.35 |
| April | 0.107258E+09 | 0.280099E+09 | 0.00 | 658129.37 | 10441.43 | 0.00 | 0.125097E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.114671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.131752E+10 | 0.00 | 11918.49 | 0.00 | 0.00 | 276804.21 | 0.00 | 0.36 |
| July | 0.00 | 0.166029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.151259E+10 | 0.00 | 3482.75 | 0.00 | 0.00 | 19484.65 | 0.00 | 0.36 |
| September | 0.00 | 0.129188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13026463.16 | 0.939758E+09 | 0.00 | 692484.27 | 0.00 | 0.00 | 97067202.88 | 0.00 | 0.36 |
| November | 92650176.34 | 0.267447E+09 | 0.00 | 1988755.82 | 0.00 | 0.00 | 0.307830E+09 | 0.00 | 0.35 |
| December | 0.431718E+09 | 0.151410E+09 | 0.00 | 1127564.17 | 0.00 | 0.00 | 0.209834E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.212896E+10 | 0.879261E+10 | 0.00 | 6270672.96 | 152046.39 | 34315495.81 | 0.110851E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 49164672.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.634894E+09 | 0.166029E+10 | 0.00 | 1988755.82 | 133873.89 | 22156363.88 | 0.307830E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.652198E+09 | 29803816.24 | 0.00 | 143582.39 | 497403.77 | 42941993.83 | 41919905.73 | 0.00 | 0.35 |
| February | 0.397629E+09 | 43422428.02 | 0.00 | 188648.97 | 1235802.28 | 94734141.86 | 53811014.37 | 0.00 | 0.35 |
| March | 0.402861E+09 | 85748432.92 | 0.00 | 181897.12 | 1210966.49 | 52709277.20 | 50675591.98 | 0.00 | 0.35 |
| April | 0.138794E+09 | 0.263450E+09 | 0.00 | 468045.17 | 16033.57 | 0.00 | 97455191.69 | 0.00 | 0.36 |
| May | 0.00 | 0.114646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.132692E+10 | 0.00 | 11626.20 | 0.00 | 0.00 | 259545.63 | 0.00 | 0.36 |
| July | 0.00 | 0.166578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.150084E+10 | 0.00 | 3378.13 | 0.00 | 0.00 | 25318.96 | 0.00 | 0.36 |
| September | 0.00 | 0.125628E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 33644299.02 | 0.886238E+09 | 0.00 | 496712.71 | 0.00 | 0.00 | 79473371.49 | 0.00 | 0.36 |
| November | 0.255320E+09 | 0.232180E+09 | 0.00 | 760115.18 | 0.00 | 0.00 | 0.151848E+09 | 0.00 | 0.35 |
| December | 0.528982E+09 | 0.120652E+09 | 0.00 | 229614.83 | 613385.97 | 18039188.96 | 56735523.04 | 0.00 | 0.35 |
| Annual Sum or Average | 0.240943E+10 | 0.855777E+10 | 0.00 | 2483620.70 | 3573592.08 | 0.208425E+09 | 0.532204E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 29803816.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.652198E+09 | 0.166578E+10 | 0.00 | 760115.18 | 1235802.28 | 94734141.86 | 0.151848E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.114433E+10 | 48726888.30 | 0.00 | 703813.89 | 3137248.78 | 0.00 | 0.201470E+09 | 0.00 | 0.52 |
| February | 0.865129E+09 | 78039288.26 | 0.00 | 531803.50 | 4737002.86 | 0.00 | 0.114916E+09 | 0.00 | 0.52 |
| March | 0.808679E+09 | 0.103492E+09 | 0.00 | 585803.85 | 9786501.79 | 0.00 | 0.129046E+09 | 0.00 | 0.52 |
| April | 0.541153E+09 | 0.173254E+09 | 0.00 | 559806.05 | 32305347.92 | 0.00 | 43008650.05 | 0.00 | 0.53 |
| May | 0.169531E+09 | 0.582669E+09 | 0.00 | 237306.40 | 0.128631E+09 | 0.00 | 1420035.76 | 0.00 | 0.53 |
| June | 0.134353E+09 | 0.684190E+09 | 0.00 | 138308.83 | 0.167025E+09 | 0.00 | 1757039.19 | 0.00 | 0.53 |
| July | 0.103934E+09 | 0.777900E+09 | 0.00 | 117372.86 | 0.188450E+09 | 0.00 | 1659649.65 | 0.00 | 0.53 |
| August | 0.147260E+09 | 0.835520E+09 | 0.00 | 97574.52 | 0.158362E+09 | 0.00 | 3078777.71 | 0.00 | 0.53 |
| September | 0.178618E+09 | 0.667782E+09 | 0.00 | 295188.39 | 98841031.05 | 0.00 | 3536799.16 | 0.00 | 0.53 |
| October | 0.394287E+09 | 0.495229E+09 | 0.00 | 887196.49 | 73290152.80 | 0.00 | 43513854.14 | 0.00 | 0.53 |
| November | 0.779101E+09 | 0.181642E+09 | 0.00 | 1256127.14 | 20494261.39 | 0.00 | 84195945.65 | 0.00 | 0.52 |
| December | 0.100865E+10 | 0.109036E+09 | 0.00 | 804988.74 | 7657621.55 | 0.00 | 0.156896E+09 | 0.00 | 0.52 |
| Annual Sum or Average | 0.627503E+10 | 0.473748E+10 | 0.00 | 6215290.64 | 0.892717E+09 | 0.00 | 0.784499E+09 | 0.00 | 0.53 |
| Minimum of Months | 0.103934E+09 | 48726888.30 | 0.00 | 97574.52 | 3137248.78 | 0.00 | 1420035.76 | 0.00 | 0.52 |
| Maximum of Months | 0.114433E+10 | 0.835520E+09 | 0.00 | 1256127.14 | 0.188450E+09 | 0.00 | 0.201470E+09 | 0.00 | 0.53 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.658092E+09 | 29388747.92 | 0.00 | 135772.12 | 326538.77 | 38766466.68 | 41511930.85 | 0.00 | 0.35 |
| February | 0.416403E+09 | 43330001.81 | 0.00 | 170933.61 | 1106748.54 | 86049056.47 | 48385079.73 | 0.00 | 0.35 |
| March | 0.415261E+09 | 90410425.42 | 0.00 | 180292.84 | 898278.13 | 48790120.23 | 42662866.50 | 0.00 | 0.35 |
| April | 0.143604E+09 | 0.265071E+09 | 0.00 | 458067.77 | 6201.17 | 0.00 | 93825263.70 | 0.00 | 0.36 |
| May | 0.00 | 0.115875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.133596E+10 | 0.00 | 11990.59 | 0.00 | 0.00 | 323041.76 | 0.00 | 0.36 |
| July | 0.00 | 0.167749E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.150495E+10 | 0.00 | 3438.08 | 0.00 | 0.00 | 20012.49 | 0.00 | 0.36 |
| September | 0.00 | 0.125862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 32649836.43 | 0.888608E+09 | 0.00 | 479015.00 | 0.00 | 0.00 | 81573372.03 | 0.00 | 0.36 |
| November | 0.248499E+09 | 0.232647E+09 | 0.00 | 733484.98 | 0.00 | 0.00 | 0.160472E+09 | 0.00 | 0.35 |
| December | 0.529498E+09 | 0.117319E+09 | 0.00 | 204300.17 | 396147.80 | 20889808.65 | 51308005.95 | 0.00 | 0.35 |
| Annual Sum or Average | 0.244401E+10 | 0.860255E+10 | 0.00 | 2377295.17 | 2733914.40 | 0.194495E+09 | 0.520081E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 29388747.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.658092E+09 | 0.167749E+10 | 0.00 | 733484.98 | 1106748.54 | 86049056.47 | 0.160472E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.697040E+09 | 28653648.66 | 0.00 | 175345.73 | 484878.31 | 0.00 | 63777162.61 | 0.00 | 0.35 |
| February | 0.480509E+09 | 42247435.86 | 0.00 | 253909.41 | 1181896.19 | 0.00 | 83599298.00 | 0.00 | 0.35 |
| March | 0.442972E+09 | 89267362.91 | 0.00 | 269123.89 | 1105571.65 | 0.00 | 80599990.12 | 0.00 | 0.35 |
| April | 0.101985E+09 | 0.266488E+09 | 0.00 | 577016.08 | 5510.88 | 0.00 | 0.132713E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.115614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.131765E+10 | 0.00 | 9886.47 | 0.00 | 0.00 | 200292.70 | 0.00 | 0.36 |
| July | 0.00 | 0.165038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.148143E+10 | 0.00 | 3958.60 | 0.00 | 0.00 | 36539.83 | 0.00 | 0.36 |
| September | 0.00 | 0.124268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 16623781.93 | 0.878690E+09 | 0.00 | 516192.50 | 0.00 | 0.00 | 98497806.48 | 0.00 | 0.36 |
| November | 0.187469E+09 | 0.229056E+09 | 0.00 | 886163.83 | 0.00 | 0.00 | 0.229280E+09 | 0.00 | 0.35 |
| December | 0.541168E+09 | 0.121277E+09 | 0.00 | 254458.29 | 400454.71 | 0.00 | 86896778.92 | 0.00 | 0.35 |
| Annual Sum or Average | 0.246777E+10 | 0.850397E+10 | 0.00 | 2946054.80 | 3178311.74 | 0.00 | 0.775601E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 28653648.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.697040E+09 | 0.165038E+10 | 0.00 | 886163.83 | 1181896.19 | 0.00 | 0.229280E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.697396E+09 | 28611317.04 | 0.00 | 174380.49 | 475303.97 | 0.00 | 63549309.70 | 0.00 | 0.35 |
| February | 0.480820E+09 | 42191820.26 | 0.00 | 251150.57 | 1177913.25 | 0.00 | 83706817.52 | 0.00 | 0.35 |
| March | 0.443626E+09 | 89488959.10 | 0.00 | 268065.56 | 1089777.41 | 0.00 | 80063073.45 | 0.00 | 0.35 |
| April | 0.101556E+09 | 0.266609E+09 | 0.00 | 578073.05 | 5373.98 | 0.00 | 0.133122E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.115678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.131813E+10 | 0.00 | 9865.56 | 0.00 | 0.00 | 202477.19 | 0.00 | 0.36 |
| July | 0.00 | 0.165106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.148168E+10 | 0.00 | 3963.13 | 0.00 | 0.00 | 36060.25 | 0.00 | 0.36 |
| September | 0.00 | 0.124284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 16884445.49 | 0.878823E+09 | 0.00 | 515320.99 | 0.00 | 0.00 | 98286968.61 | 0.00 | 0.36 |
| November | 0.185855E+09 | 0.229094E+09 | 0.00 | 888899.89 | 0.00 | 0.00 | 0.230925E+09 | 0.00 | 0.35 |
| December | 0.542757E+09 | 0.121075E+09 | 0.00 | 252290.13 | 396085.69 | 0.00 | 84989867.44 | 0.00 | 0.35 |
| Annual Sum or Average | 0.246889E+10 | 0.850639E+10 | 0.00 | 2942009.37 | 3144454.30 | 0.00 | 0.774881E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 28611317.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.697396E+09 | 0.165106E+10 | 0.00 | 888899.89 | 1177913.25 | 0.00 | 0.230925E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.523068E+09 | 51819148.73 | 0.00 | 1281315.03 | 0.00 | 0.00 | 0.312942E+09 | 0.00 | 0.35 |
| February | 0.395457E+09 | 72425491.93 | 0.00 | 865098.47 | 0.00 | 0.00 | 0.194340E+09 | 0.00 | 0.35 |
| March | 0.375130E+09 | 0.113329E+09 | 0.00 | 645149.15 | 0.00 | 0.00 | 0.160692E+09 | 0.00 | 0.35 |
| April | 58659273.41 | 0.285749E+09 | 0.00 | 819533.60 | 0.00 | 0.00 | 0.168983E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.115713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.130724E+10 | 0.00 | 10188.54 | 0.00 | 0.00 | 209205.04 | 0.00 | 0.36 |
| July | 0.00 | 0.164471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.149622E+10 | 0.00 | 3577.99 | 0.00 | 0.00 | 28391.07 | 0.00 | 0.36 |
| September | 0.00 | 0.128607E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 633559.56 | 0.942530E+09 | 0.00 | 764423.18 | 0.00 | 0.00 | 0.110208E+09 | 0.00 | 0.36 |
| November | 12906503.80 | 0.269068E+09 | 0.00 | 2371534.64 | 0.00 | 0.00 | 0.388056E+09 | 0.00 | 0.35 |
| December | 0.334039E+09 | 0.155980E+09 | 0.00 | 1518613.66 | 0.00 | 0.00 | 0.330406E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.169989E+10 | 0.878227E+10 | 0.00 | 8279434.26 | 0.00 | 0.00 | 0.166586E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 51819148.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.523068E+09 | 0.164471E+10 | 0.00 | 2371534.64 | 0.00 | 0.00 | 0.388056E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.499871E+09 | 53761532.39 | 0.00 | 1439609.49 | 0.00 | 0.00 | 0.335488E+09 | 0.00 | 0.35 |
| February | 0.382251E+09 | 74727396.68 | 0.00 | 947625.33 | 0.00 | 0.00 | 0.204689E+09 | 0.00 | 0.35 |
| March | 0.357865E+09 | 0.118346E+09 | 0.00 | 733604.79 | 0.00 | 0.00 | 0.176457E+09 | 0.00 | 0.35 |
| April | 43395114.39 | 0.298571E+09 | 0.00 | 911649.52 | 0.00 | 0.00 | 0.178993E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.119716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134691E+10 | 0.00 | 6151.58 | 0.00 | 0.00 | 99975.77 | 0.00 | 0.36 |
| July | 0.00 | 0.169183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.153658E+10 | 0.00 | 1900.59 | 0.00 | 0.00 | 6042.02 | 0.00 | 0.36 |
| September | 0.00 | 0.132487E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.968877E+09 | 0.00 | 853886.48 | 0.00 | 0.00 | 0.108874E+09 | 0.00 | 0.36 |
| November | 4328114.53 | 0.277512E+09 | 0.00 | 2571499.12 | 0.00 | 0.00 | 0.392873E+09 | 0.00 | 0.35 |
| December | 0.295262E+09 | 0.162762E+09 | 0.00 | 1666622.11 | 0.00 | 0.00 | 0.369389E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.158297E+10 | 0.905192E+10 | 0.00 | 9132548.99 | 0.00 | 0.00 | 0.176687E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 53761532.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.499871E+09 | 0.169183E+10 | 0.00 | 2571499.12 | 0.00 | 0.00 | 0.392873E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.125960E+10 | 0.100420E+09 | 0.00 | 1741576.21 | 0.00 | 0.00 | 0.317973E+09 | 0.00 | 0.35 |
| February | 0.726463E+09 | 0.156264E+09 | 0.00 | 2054504.77 | 0.00 | 46356946.11 | 0.341463E+09 | 0.00 | 0.35 |
| March | 0.688323E+09 | 0.251555E+09 | 0.00 | 1661833.08 | 0.00 | 44773969.37 | 0.295297E+09 | 0.00 | 0.35 |
| April | 0.109375E+09 | 0.633921E+09 | 0.00 | 2281736.63 | 0.00 | 0.00 | 0.304948E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.238112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.270128E+10 | 0.00 | 21655.83 | 0.00 | 0.00 | 286973.65 | 0.00 | 0.36 |
| July | 0.00 | 0.331391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.291957E+10 | 0.00 | 9258.85 | 0.00 | 0.00 | 97236.88 | 0.00 | 0.36 |
| September | 0.00 | 0.245962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 71365009.79 | 0.178560E+10 | 0.00 | 1120070.27 | 0.00 | 0.00 | 0.149936E+09 | 0.00 | 0.36 |
| November | 0.310495E+09 | 0.513964E+09 | 0.00 | 3642891.59 | 0.00 | 0.00 | 0.487117E+09 | 0.00 | 0.35 |
| December | 0.872780E+09 | 0.285810E+09 | 0.00 | 2153105.78 | 0.00 | 36691426.32 | 0.343140E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.403840E+10 | 0.175030E+11 | 0.00 | 14686633.00 | 0.00 | 0.127822E+09 | 0.224026E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.100420E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.125960E+10 | 0.331391E+10 | 0.00 | 3642891.59 | 0.00 | 46356946.11 | 0.487117E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.113806E+10 | 67378104.95 | 0.00 | 402824.36 | 574447.37 | 0.226383E+09 | 83356170.41 | 0.00 | 0.35 |
| February | 0.765131E+09 | 0.109950E+09 | 0.00 | 842537.23 | 878332.83 | 0.155744E+09 | 0.158677E+09 | 0.00 | 0.35 |
| March | 0.780617E+09 | 0.219486E+09 | 0.00 | 861930.95 | 388001.67 | 72344414.97 | 0.152431E+09 | 0.00 | 0.35 |
| April | 0.143170E+09 | 0.607963E+09 | 0.00 | 1853591.39 | 0.00 | 0.00 | 0.278018E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.237662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.271196E+10 | 0.00 | 21808.22 | 0.00 | 0.00 | 284139.89 | 0.00 | 0.36 |
| July | 0.00 | 0.331784E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.288941E+10 | 0.00 | 10121.40 | 0.00 | 0.00 | 121345.64 | 0.00 | 0.36 |
| September | 0.00 | 0.238060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.123986E+09 | 0.167274E+10 | 0.00 | 710230.22 | 0.00 | 0.00 | 0.100459E+09 | 0.00 | 0.36 |
| November | 0.563329E+09 | 0.442601E+09 | 0.00 | 1284736.03 | 19116.92 | 0.00 | 0.233208E+09 | 0.00 | 0.35 |
| December | 0.930216E+09 | 0.227734E+09 | 0.00 | 425245.24 | 1704065.46 | 0.152235E+09 | 93378675.39 | 0.00 | 0.35 |
| Annual Sum or Average | 0.444451E+10 | 0.170243E+11 | 0.00 | 6413025.04 | 3563964.26 | 0.606707E+09 | 0.109993E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 67378104.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.113806E+10 | 0.331784E+10 | 0.00 | 1853591.39 | 1704065.46 | 0.226383E+09 | 0.278018E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.127525E+10 | 99391696.69 | 0.00 | 1570409.62 | 0.00 | 0.00 | 0.310323E+09 | 0.00 | 0.35 |
| February | 0.735012E+09 | 0.156059E+09 | 0.00 | 2004727.68 | 0.00 | 40953684.90 | 0.348597E+09 | 0.00 | 0.35 |
| March | 0.686200E+09 | 0.257062E+09 | 0.00 | 1646577.29 | 0.00 | 43144695.67 | 0.302643E+09 | 0.00 | 0.35 |
| April | 97098094.44 | 0.633237E+09 | 0.00 | 2318623.53 | 0.00 | 0.00 | 0.321499E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.239545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.271113E+10 | 0.00 | 25388.98 | 0.00 | 0.00 | 416729.47 | 0.00 | 0.36 |
| July | 0.00 | 0.332851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.292013E+10 | 0.00 | 9405.35 | 0.00 | 0.00 | 92994.65 | 0.00 | 0.36 |
| September | 0.00 | 0.245725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 73071955.35 | 0.178420E+10 | 0.00 | 1086685.41 | 0.00 | 0.00 | 0.150370E+09 | 0.00 | 0.36 |
| November | 0.294118E+09 | 0.512447E+09 | 0.00 | 3701455.02 | 0.00 | 0.00 | 0.506480E+09 | 0.00 | 0.35 |
| December | 0.876155E+09 | 0.279428E+09 | 0.00 | 2053396.87 | 0.00 | 39118168.78 | 0.338658E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.403691E+10 | 0.175343E+11 | 0.00 | 14416669.76 | 0.00 | 0.123217E+09 | 0.227908E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 99391696.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.127525E+10 | 0.332851E+10 | 0.00 | 3701455.02 | 0.00 | 43144695.67 | 0.506480E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.115175E+10 | 66946860.95 | 0.00 | 387137.39 | 325345.66 | 0.214640E+09 | 83211824.08 | 0.00 | 0.35 |
| February | 0.769009E+09 | 0.111333E+09 | 0.00 | 812166.14 | 712435.90 | 0.148418E+09 | 0.173447E+09 | 0.00 | 0.35 |
| March | 0.784620E+09 | 0.228023E+09 | 0.00 | 851363.21 | 41748.37 | 68701638.63 | 0.154658E+09 | 0.00 | 0.35 |
| April | 0.136184E+09 | 0.611344E+09 | 0.00 | 1885757.09 | 0.00 | 0.00 | 0.288694E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.239870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.272919E+10 | 0.00 | 24517.35 | 0.00 | 0.00 | 389485.60 | 0.00 | 0.36 |
| July | 0.00 | 0.334019E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.289827E+10 | 0.00 | 9104.45 | 0.00 | 0.00 | 106493.93 | 0.00 | 0.36 |
| September | 0.00 | 0.238591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.127211E+09 | 0.167815E+10 | 0.00 | 667312.45 | 0.00 | 0.00 | 99449113.21 | 0.00 | 0.36 |
| November | 0.569962E+09 | 0.444006E+09 | 0.00 | 1199250.48 | 0.00 | 0.00 | 0.231694E+09 | 0.00 | 0.35 |
| December | 0.936748E+09 | 0.221875E+09 | 0.00 | 379163.08 | 989337.17 | 0.156536E+09 | 78286289.88 | 0.00 | 0.35 |
| Annual Sum or Average | 0.447549E+10 | 0.171139E+11 | 0.00 | 6215771.63 | 2068867.09 | 0.588296E+09 | 0.110994E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 66946860.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.115175E+10 | 0.334019E+10 | 0.00 | 1885757.09 | 989337.17 | 0.214640E+09 | 0.288694E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.137620E+10 | 68082776.89 | 0.00 | 503409.40 | 402463.36 | 0.00 | 0.118477E+09 | 0.00 | 0.35 |
| February | 0.883828E+09 | 0.107595E+09 | 0.00 | 1042617.69 | 657646.98 | 11328304.43 | 0.222284E+09 | 0.00 | 0.35 |
| March | 0.782388E+09 | 0.221987E+09 | 0.00 | 1136414.85 | 863983.66 | 0.00 | 0.256664E+09 | 0.00 | 0.35 |
| April | 64750466.24 | 0.597192E+09 | 0.00 | 2020195.78 | 0.00 | 0.00 | 0.358940E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.236754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.267083E+10 | 0.00 | 14318.47 | 0.00 | 0.00 | 278435.69 | 0.00 | 0.36 |
| July | 0.00 | 0.327990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.286786E+10 | 0.00 | 10062.54 | 0.00 | 0.00 | 139874.40 | 0.00 | 0.36 |
| September | 0.00 | 0.237731E+10 | 0.00 | 1667.05 | 0.00 | 0.00 | 4056.61 | 0.00 | 0.36 |
| October | 75387897.60 | 0.167725E+10 | 0.00 | 846151.03 | 0.00 | 0.00 | 0.155499E+09 | 0.00 | 0.36 |
| November | 0.452776E+09 | 0.443216E+09 | 0.00 | 1617365.46 | 0.00 | 0.00 | 0.370316E+09 | 0.00 | 0.35 |
| December | 0.109104E+10 | 0.234553E+09 | 0.00 | 490189.12 | 954699.96 | 5640019.58 | 0.136589E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.472637E+10 | 0.169133E+11 | 0.00 | 7682391.39 | 2878793.96 | 16968324.00 | 0.161919E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 68082776.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.137620E+10 | 0.327990E+10 | 0.00 | 2020195.78 | 954699.96 | 11328304.43 | 0.370316E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.137684E+10 | 68035052.07 | 0.00 | 501028.09 | 398775.98 | 0.00 | 0.117918E+09 | 0.00 | 0.35 |
| February | 0.883863E+09 | 0.107630E+09 | 0.00 | 1038128.73 | 654676.00 | 8946481.57 | 0.225352E+09 | 0.00 | 0.35 |
| March | 0.781427E+09 | 0.222396E+09 | 0.00 | 1138280.34 | 847407.54 | 0.00 | 0.258031E+09 | 0.00 | 0.35 |
| April | 64103632.54 | 0.597366E+09 | 0.00 | 2023126.84 | 0.00 | 0.00 | 0.359663E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.236859E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.267165E+10 | 0.00 | 14447.99 | 0.00 | 0.00 | 281205.70 | 0.00 | 0.36 |
| July | 0.00 | 0.328107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.286835E+10 | 0.00 | 10075.22 | 0.00 | 0.00 | 138391.24 | 0.00 | 0.36 |
| September | 0.00 | 0.237763E+10 | 0.00 | 1667.99 | 0.00 | 0.00 | 3904.86 | 0.00 | 0.36 |
| October | 75456407.51 | 0.167753E+10 | 0.00 | 843254.80 | 0.00 | 0.00 | 0.155564E+09 | 0.00 | 0.36 |
| November | 0.452414E+09 | 0.443374E+09 | 0.00 | 1623434.09 | 0.00 | 0.00 | 0.370815E+09 | 0.00 | 0.35 |
| December | 0.109100E+10 | 0.234241E+09 | 0.00 | 487362.34 | 938822.49 | 5640014.30 | 0.135856E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.472511E+10 | 0.169179E+11 | 0.00 | 7680806.44 | 2839682.02 | 14586495.87 | 0.162362E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 68035052.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.137684E+10 | 0.328107E+10 | 0.00 | 2023126.84 | 938822.49 | 8946481.57 | 0.370815E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.101411E+10 | 0.104803E+09 | 0.00 | 3005129.52 | 0.00 | 0.00 | 0.642992E+09 | 0.00 | 0.35 |
| February | 0.612303E+09 | 0.158460E+09 | 0.00 | 2829146.46 | 0.00 | 0.00 | 0.539020E+09 | 0.00 | 0.35 |
| March | 0.595575E+09 | 0.256755E+09 | 0.00 | 2239935.44 | 0.00 | 0.00 | 0.466921E+09 | 0.00 | 0.35 |
| April | 10376084.69 | 0.623879E+09 | 0.00 | 2562228.49 | 0.00 | 0.00 | 0.404964E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.236402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.264863E+10 | 0.00 | 14959.74 | 0.00 | 0.00 | 292868.03 | 0.00 | 0.36 |
| July | 0.00 | 0.326598E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.289573E+10 | 0.00 | 9767.51 | 0.00 | 0.00 | 121303.45 | 0.00 | 0.36 |
| September | 0.00 | 0.246376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 23943598.66 | 0.180422E+10 | 0.00 | 1312388.40 | 0.00 | 0.00 | 0.200370E+09 | 0.00 | 0.36 |
| November | 0.113801E+09 | 0.520418E+09 | 0.00 | 4554492.49 | 0.00 | 0.00 | 0.689322E+09 | 0.00 | 0.35 |
| December | 0.756743E+09 | 0.297924E+09 | 0.00 | 3031316.54 | 0.00 | 0.00 | 0.551135E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.312685E+10 | 0.174046E+11 | 0.00 | 19559364.60 | 0.00 | 0.00 | 0.349514E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.104803E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.101411E+10 | 0.326598E+10 | 0.00 | 4554492.49 | 0.00 | 0.00 | 0.689322E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.101376E+10 | 0.104820E+09 | 0.00 | 3011063.77 | 0.00 | 0.00 | 0.643589E+09 | 0.00 | 0.35 |
| February | 0.610022E+09 | 0.158512E+09 | 0.00 | 2832086.27 | 0.00 | 0.00 | 0.541605E+09 | 0.00 | 0.35 |
| March | 0.593903E+09 | 0.257082E+09 | 0.00 | 2244574.63 | 0.00 | 0.00 | 0.468753E+09 | 0.00 | 0.35 |
| April | 10258278.43 | 0.624021E+09 | 0.00 | 2563104.40 | 0.00 | 0.00 | 0.405141E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.236506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.264948E+10 | 0.00 | 15362.37 | 0.00 | 0.00 | 295768.97 | 0.00 | 0.36 |
| July | 0.00 | 0.326717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.289620E+10 | 0.00 | 9565.87 | 0.00 | 0.00 | 120086.68 | 0.00 | 0.36 |
| September | 0.00 | 0.246407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 23999864.85 | 0.180447E+10 | 0.00 | 1310425.79 | 0.00 | 0.00 | 0.200381E+09 | 0.00 | 0.36 |
| November | 0.115004E+09 | 0.520511E+09 | 0.00 | 4557425.32 | 0.00 | 0.00 | 0.688117E+09 | 0.00 | 0.35 |
| December | 0.759453E+09 | 0.297748E+09 | 0.00 | 3021719.92 | 0.00 | 0.00 | 0.548256E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.312640E+10 | 0.174091E+11 | 0.00 | 19565328.34 | 0.00 | 0.00 | 0.349626E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.104820E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.101376E+10 | 0.326717E+10 | 0.00 | 4557425.32 | 0.00 | 0.00 | 0.688117E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.329509E+09 | 45355769.47 | 0.00 | 732414.37 | 79236.35 | 0.319668E+09 | 92036926.58 | 0.00 | 0.35 |
| February | 0.279637E+09 | 74414801.48 | 0.00 | 608245.62 | 234528.82 | 0.186391E+09 | 74028817.76 | 0.00 | 0.35 |
| March | 0.239283E+09 | 0.114491E+09 | 9659.50 | 608529.28 | 130097.41 | 0.174519E+09 | 67106063.69 | 131.57 | 0.35 |
| April | 0.132196E+09 | 0.296483E+09 | 0.00 | 733063.18 | 111027.88 | 0.00 | 79688037.88 | 0.00 | 0.36 |
| May | 0.00 | 0.116418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134126E+10 | 0.00 | 14657.79 | 0.00 | 0.00 | 944456.27 | 0.00 | 0.36 |
| July | 0.00 | 0.164873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.143722E+10 | 0.00 | 5248.07 | 0.00 | 0.00 | 183390.98 | 0.00 | 0.36 |
| September | 0.00 | 0.118556E+10 | 0.00 | 1273.07 | 0.00 | 0.00 | 5162.86 | 0.00 | 0.36 |
| October | 65434015.07 | 0.858016E+09 | 0.00 | 337346.34 | 13911.25 | 4207336.19 | 34219317.37 | 0.00 | 0.36 |
| November | 0.234561E+09 | 0.239169E+09 | 0.00 | 1138423.03 | 14577.78 | 37437275.60 | 99568337.86 | 0.00 | 0.35 |
| December | 0.253514E+09 | 0.125179E+09 | 43373.56 | 794447.79 | 74931.98 | 0.238731E+09 | 88069103.25 | 871.69 | 0.35 |
| Annual Sum or Average | 0.153413E+10 | 0.853006E+10 | 53033.06 | 4973648.53 | 658311.47 | 0.960954E+09 | 0.535850E+09 | 1003.26 | 0.36 |
| Minimum of Months | 0.00 | 45355769.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.329509E+09 | 0.164873E+10 | 43373.56 | 1138423.03 | 234528.82 | 0.319668E+09 | 99568337.86 | 871.69 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.224146E+09 | 31932829.56 | 127928.03 | 137175.46 | 413394.38 | 0.460422E+09 | 19869954.35 | 509.74 | 0.35 |
| February | 0.231271E+09 | 53140892.31 | 0.00 | 211634.18 | 1072495.44 | 0.258801E+09 | 33280765.95 | 0.00 | 0.35 |
| March | 0.221368E+09 | 0.101764E+09 | 52807.05 | 316280.81 | 563631.55 | 0.210222E+09 | 38839244.80 | 693.71 | 0.35 |
| April | 0.142184E+09 | 0.286060E+09 | 0.00 | 571148.68 | 176780.52 | 429859.81 | 68395537.87 | 0.00 | 0.36 |
| May | 0.00 | 0.116441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134754E+10 | 0.00 | 14320.59 | 0.00 | 0.00 | 970669.01 | 0.00 | 0.36 |
| July | 0.00 | 0.165216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.142583E+10 | 0.00 | 5561.90 | 0.00 | 0.00 | 195852.73 | 0.00 | 0.36 |
| September | 0.00 | 0.115229E+10 | 0.00 | 2947.45 | 0.00 | 0.00 | 20610.84 | 0.00 | 0.36 |
| October | 70079052.32 | 0.810027E+09 | 0.00 | 195757.35 | 265289.85 | 7701644.00 | 23797070.91 | 0.00 | 0.36 |
| November | 0.228393E+09 | 0.206510E+09 | 0.00 | 298990.13 | 946870.76 | 84555717.46 | 41264019.59 | 0.00 | 0.35 |
| December | 0.198916E+09 | 0.100417E+09 | 90134.25 | 144800.76 | 1259509.05 | 0.333586E+09 | 23088612.32 | 5652.52 | 0.35 |
| Annual Sum or Average | 0.131636E+10 | 0.833208E+10 | 270869.32 | 1898617.30 | 4697971.53 | 0.135572E+10 | 0.249722E+09 | 6855.97 | 0.36 |
| Minimum of Months | 0.00 | 31932829.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.231271E+09 | 0.165216E+10 | 127928.03 | 571148.68 | 1259509.05 | 0.460422E+09 | 68395537.87 | 5652.52 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.341926E+09 | 45082726.11 | 0.00 | 599036.86 | 42245.57 | 0.312834E+09 | 89739480.56 | 0.00 | 0.35 |
| February | 0.288355E+09 | 75001365.10 | 0.00 | 560101.75 | 74926.22 | 0.183339E+09 | 72947583.12 | 0.00 | 0.35 |
| March | 0.247789E+09 | 0.117801E+09 | 0.00 | 566352.07 | 23231.79 | 0.168543E+09 | 67685906.75 | 0.00 | 0.35 |
| April | 0.134655E+09 | 0.296895E+09 | 0.00 | 716056.12 | 44896.59 | 0.00 | 80828024.24 | 0.00 | 0.36 |
| May | 0.00 | 0.117100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134594E+10 | 0.00 | 13899.47 | 0.00 | 0.00 | 1072715.63 | 0.00 | 0.36 |
| July | 0.00 | 0.165486E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.143745E+10 | 0.00 | 6059.04 | 0.00 | 0.00 | 201688.79 | 0.00 | 0.36 |
| September | 0.00 | 0.118463E+10 | 0.00 | 1311.35 | 0.00 | 0.00 | 7413.66 | 0.00 | 0.36 |
| October | 68188078.31 | 0.857571E+09 | 0.00 | 312673.71 | 0.00 | 3060100.55 | 33654925.15 | 0.00 | 0.36 |
| November | 0.235617E+09 | 0.238892E+09 | 0.00 | 1066122.50 | 0.00 | 37510810.88 | 0.101667E+09 | 0.00 | 0.35 |
| December | 0.260015E+09 | 0.122915E+09 | 0.00 | 682556.31 | 107574.90 | 0.238437E+09 | 83598641.34 | 0.00 | 0.35 |
| Annual Sum or Average | 0.157655E+10 | 0.854804E+10 | 0.00 | 4524169.17 | 292875.06 | 0.943724E+09 | 0.531403E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 45082726.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.341926E+09 | 0.165486E+10 | 0.00 | 1066122.50 | 107574.90 | 0.312834E+09 | 0.101667E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.222022E+09 | 31901348.10 | 29915.97 | 119358.90 | 219576.76 | 0.461856E+09 | 19777333.46 | 93.05 | 0.35 |
| February | 0.237553E+09 | 54129705.99 | 0.00 | 186992.33 | 507343.21 | 0.255409E+09 | 33940469.75 | 0.00 | 0.35 |
| March | 0.232661E+09 | 0.106062E+09 | 0.00 | 284964.24 | 82255.88 | 0.203706E+09 | 35756256.97 | 0.00 | 0.35 |
| April | 0.147750E+09 | 0.287056E+09 | 0.00 | 546075.29 | 46138.17 | 77040.73 | 66759930.47 | 0.00 | 0.36 |
| May | 0.00 | 0.117119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.135188E+10 | 0.00 | 14316.83 | 0.00 | 0.00 | 1097422.81 | 0.00 | 0.36 |
| July | 0.00 | 0.165816E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.142655E+10 | 0.00 | 5940.67 | 0.00 | 0.00 | 216906.90 | 0.00 | 0.36 |
| September | 0.00 | 0.115212E+10 | 0.00 | 3465.52 | 0.00 | 0.00 | 25836.44 | 0.00 | 0.36 |
| October | 71735415.37 | 0.810944E+09 | 0.00 | 180809.98 | 56063.42 | 9168130.68 | 20841377.29 | 0.00 | 0.36 |
| November | 0.244546E+09 | 0.207075E+09 | 0.00 | 262942.67 | 177786.53 | 73361487.75 | 37556393.02 | 0.00 | 0.35 |
| December | 0.202132E+09 | 98360480.99 | 53655.20 | 112916.79 | 448025.11 | 0.331920E+09 | 19934696.18 | 3254.79 | 0.35 |
| Annual Sum or Average | 0.135840E+10 | 0.835544E+10 | 83571.17 | 1717783.21 | 1537189.08 | 0.133550E+10 | 0.235907E+09 | 3347.83 | 0.36 |
| Minimum of Months | 0.00 | 31901348.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.244546E+09 | 0.165816E+10 | 53655.20 | 546075.29 | 507343.21 | 0.461856E+09 | 66759930.47 | 3254.79 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.285790E+09 | 31848379.33 | 10238.01 | 144795.88 | 482977.43 | 0.396795E+09 | 31290254.68 | 3.90 | 0.35 |
| February | 0.275343E+09 | 50997315.55 | 0.00 | 210096.39 | 766926.68 | 0.218638E+09 | 42700729.09 | 0.00 | 0.35 |
| March | 0.276571E+09 | 0.103487E+09 | 26276.19 | 294179.15 | 466118.45 | 0.157224E+09 | 46834121.97 | 164.46 | 0.35 |
| April | 0.131197E+09 | 0.285067E+09 | 0.00 | 540499.86 | 110547.20 | 0.00 | 85447343.90 | 0.00 | 0.36 |
| May | 0.00 | 0.117752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134419E+10 | 0.00 | 14003.57 | 0.00 | 0.00 | 558998.03 | 0.00 | 0.36 |
| July | 0.00 | 0.165378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.143523E+10 | 0.00 | 5387.86 | 0.00 | 0.00 | 166115.74 | 0.00 | 0.36 |
| September | 0.00 | 0.116955E+10 | 0.00 | 2380.15 | 0.00 | 0.00 | 9037.54 | 0.00 | 0.36 |
| October | 76565821.06 | 0.824650E+09 | 0.00 | 188363.35 | 185772.53 | 0.00 | 29822364.33 | 0.00 | 0.36 |
| November | 0.279472E+09 | 0.207060E+09 | 0.00 | 294359.52 | 826586.72 | 35895123.14 | 51195644.20 | 0.00 | 0.35 |
| December | 0.283796E+09 | 0.102030E+09 | 58586.33 | 119241.85 | 1225874.33 | 0.258109E+09 | 20798932.13 | 1825.31 | 0.35 |
| Annual Sum or Average | 0.160874E+10 | 0.838541E+10 | 95100.53 | 1813307.58 | 4064803.35 | 0.106666E+10 | 0.308824E+09 | 1993.66 | 0.36 |
| Minimum of Months | 0.00 | 31848379.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.285790E+09 | 0.165378E+10 | 58586.33 | 540499.86 | 1225874.33 | 0.396795E+09 | 85447343.90 | 1825.31 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.285399E+09 | 31929485.82 | 10238.86 | 143925.39 | 468923.60 | 0.397203E+09 | 31230677.05 | 1.80 | 0.35 |
| February | 0.275270E+09 | 51158970.41 | 0.00 | 209263.95 | 759977.12 | 0.218809E+09 | 42774347.12 | 0.00 | 0.35 |
| March | 0.275990E+09 | 0.103842E+09 | 26191.21 | 294996.92 | 428740.83 | 0.157984E+09 | 46697099.20 | 140.00 | 0.35 |
| April | 0.131849E+09 | 0.285264E+09 | 0.00 | 540574.49 | 97228.95 | 0.00 | 84884969.27 | 0.00 | 0.36 |
| May | 0.00 | 0.117821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134477E+10 | 0.00 | 14299.58 | 0.00 | 0.00 | 564716.67 | 0.00 | 0.36 |
| July | 0.00 | 0.165451E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.143564E+10 | 0.00 | 5389.56 | 0.00 | 0.00 | 165433.20 | 0.00 | 0.36 |
| September | 0.00 | 0.116987E+10 | 0.00 | 2166.38 | 0.00 | 0.00 | 8880.25 | 0.00 | 0.36 |
| October | 76983161.40 | 0.824952E+09 | 0.00 | 186443.59 | 184208.71 | 0.00 | 29357296.20 | 0.00 | 0.36 |
| November | 0.279650E+09 | 0.207288E+09 | 0.00 | 295123.91 | 757434.16 | 35818853.07 | 51056021.21 | 0.00 | 0.35 |
| December | 0.282072E+09 | 0.101971E+09 | 58607.36 | 117832.79 | 1193148.60 | 0.259727E+09 | 20672473.09 | 1818.70 | 0.35 |
| Annual Sum or Average | 0.160721E+10 | 0.838941E+10 | 95037.44 | 1810016.57 | 3889661.98 | 0.106954E+10 | 0.307412E+09 | 1960.51 | 0.36 |
| Minimum of Months | 0.00 | 31929485.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.285399E+09 | 0.165451E+10 | 58607.36 | 540574.49 | 1193148.60 | 0.397203E+09 | 84884969.27 | 1818.70 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.412437E+09 | 47513484.54 | 0.00 | 772765.30 | 28995.59 | 0.217635E+09 | 0.132752E+09 | 0.00 | 0.35 |
| February | 0.310782E+09 | 75707837.31 | 0.00 | 655355.17 | 52923.27 | 0.136363E+09 | 0.111389E+09 | 0.00 | 0.35 |
| March | 0.288723E+09 | 0.118409E+09 | 0.00 | 585243.52 | 69452.96 | 0.118031E+09 | 88867197.61 | 0.00 | 0.35 |
| April | 0.116264E+09 | 0.297500E+09 | 0.00 | 731209.70 | 57566.05 | 0.00 | 0.100903E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.117710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.133658E+10 | 0.00 | 12487.58 | 0.00 | 0.00 | 550175.97 | 0.00 | 0.36 |
| July | 0.00 | 0.164953E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.144882E+10 | 0.00 | 5492.83 | 0.00 | 0.00 | 153528.92 | 0.00 | 0.36 |
| September | 0.00 | 0.120905E+10 | 0.00 | 689.15 | 0.00 | 0.00 | 1290.80 | 0.00 | 0.36 |
| October | 64663898.54 | 0.881742E+09 | 0.00 | 348981.57 | 0.00 | 0.00 | 44433521.23 | 0.00 | 0.36 |
| November | 0.248433E+09 | 0.245279E+09 | 0.00 | 1200089.97 | 425.60 | 4008491.22 | 0.134959E+09 | 0.00 | 0.35 |
| December | 0.347567E+09 | 0.131451E+09 | 0.00 | 845412.78 | 91754.58 | 0.136880E+09 | 0.112032E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.178887E+10 | 0.861869E+10 | 0.00 | 5157727.56 | 301118.06 | 0.612917E+09 | 0.726040E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 47513484.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.412437E+09 | 0.164953E+10 | 0.00 | 1200089.97 | 91754.58 | 0.217635E+09 | 0.134959E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.409474E+09 | 47571203.91 | 0.00 | 774919.66 | 28287.93 | 0.217531E+09 | 0.135907E+09 | 0.00 | 0.35 |
| February | 0.311840E+09 | 75826331.94 | 0.00 | 655116.58 | 52995.91 | 0.136074E+09 | 0.110788E+09 | 0.00 | 0.35 |
| March | 0.288520E+09 | 0.118686E+09 | 0.00 | 588725.30 | 66711.89 | 0.118014E+09 | 89144021.21 | 0.00 | 0.35 |
| April | 0.116563E+09 | 0.297660E+09 | 0.00 | 731538.91 | 56947.82 | 0.00 | 0.100680E+09 | 0.00 | 0.36 |
| May | 0.00 | 0.117777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.133716E+10 | 0.00 | 12438.58 | 0.00 | 0.00 | 555728.38 | 0.00 | 0.36 |
| July | 0.00 | 0.165025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.144920E+10 | 0.00 | 5494.50 | 0.00 | 0.00 | 152885.12 | 0.00 | 0.36 |
| September | 0.00 | 0.120933E+10 | 0.00 | 689.39 | 0.00 | 0.00 | 1211.99 | 0.00 | 0.36 |
| October | 64809895.98 | 0.881990E+09 | 0.00 | 348439.75 | 0.00 | 0.00 | 44309090.69 | 0.00 | 0.36 |
| November | 0.249089E+09 | 0.245411E+09 | 0.00 | 1201446.30 | 329.54 | 4008275.00 | 0.134297E+09 | 0.00 | 0.35 |
| December | 0.346626E+09 | 0.131418E+09 | 0.00 | 843149.94 | 91954.79 | 0.137071E+09 | 0.112718E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.178692E+10 | 0.862227E+10 | 0.00 | 5161958.90 | 297227.89 | 0.612698E+09 | 0.728554E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 47571203.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.409474E+09 | 0.165025E+10 | 0.00 | 1201446.30 | 91954.79 | 0.217531E+09 | 0.135907E+09 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:16:53
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.125025E+12 | 0.134235E+11 | 0.00 | 0.129433E+10 | 0.266337E+11 |
| February | 0.127078E+12 | 0.102454E+11 | 0.00 | 0.897801E+09 | 0.355208E+11 |
| March | 0.133406E+12 | 0.987723E+10 | 0.00 | 0.825033E+09 | 0.468547E+11 |
| April | 0.140973E+12 | 0.262016E+10 | 0.00 | 0.379162E+09 | 0.902669E+11 |
| May | 0.138260E+12 | -0.113974E+11 | 0.00 | -540111783.9 | 0.194958E+12 |
| June | 0.134846E+12 | -0.940406E+10 | 0.00 | -714967179.4 | 0.201791E+12 |
| July | 0.141807E+12 | -0.132702E+11 | 0.00 | -860638859.8 | 0.228518E+12 |
| August | 0.134240E+12 | -0.143048E+11 | 0.00 | -843445182.2 | 0.223211E+12 |
| September | 0.119380E+12 | -0.132630E+11 | 0.00 | -584173483.8 | 0.199203E+12 |
| October | 0.129349E+12 | -0.708806E+10 | 0.00 | -129831832.7 | 0.169904E+12 |
| November | 0.106775E+12 | 0.662222E+10 | 0.00 | 0.662417E+09 | 0.730232E+11 |
| December | 0.113240E+12 | 0.109047E+11 | 0.00 | 0.104966E+10 | 0.472969E+11 |
| Annual Sum or Average | 0.154438E+13 | -0.150342E+11 | 0.00 | 0.143523E+10 | 0.153718E+13 |
| Minimum of Months | 0.106775E+12 | -0.143048E+11 | 0.00 | -860638859.8 | 0.266337E+11 |
| Maximum of Months | 0.141807E+12 | 0.134235E+11 | 0.00 | 0.129433E+10 | 0.228518E+12 |