Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:15
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885
Simulation Timestamp: 2023-10-16 09:15:07
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1461.53 | 466.26 | 517.54 |
| Net Site Energy | 1461.53 | 466.26 | 517.54 |
| Total Source Energy | 4064.97 | 1296.80 | 1439.45 |
| Net Source Energy | 4064.97 | 1296.80 | 1439.45 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 270.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 33.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 49.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 71.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 478.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1190.91 | 270.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 270.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 33.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 94.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 4.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 49.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 388.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 65.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 5.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 71.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 478.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 270.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 33.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 99.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 49.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 458.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 71.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 478.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.32 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 52.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 206.48 | 95.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 162.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 421.71 | 95.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 47.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 186.02 | 86.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 146.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 379.92 | 86.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1190.911 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1190.911 | 100.00 |
| Total On-Site and Utility Electric Sources | 1190.911 | 100.00 |
| Total Electricity End Uses | 1190.911 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 0.00 | 52.51 |
| Air to Air Heat Recovery for Heating | 0.00 | 47.49 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 0.00 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.32 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.32 | 100.00 |
| Total Water End Uses | 1875.32 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8760.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| G SW APARTMENT WATER HEATER | G NW APARTMENT WATER HEATER | G NE APARTMENT WATER HEATER | G N1 APARTMENT WATER HEATER | G N2 APARTMENT WATER HEATER | G S1 APARTMENT WATER HEATER | G S2 APARTMENT WATER HEATER | M SW APARTMENT WATER HEATER | M NW APARTMENT WATER HEATER | M SE APARTMENT WATER HEATER | M NE APARTMENT WATER HEATER | M N1 APARTMENT WATER HEATER | M N2 APARTMENT WATER HEATER | M S1 APARTMENT WATER HEATER | M S2 APARTMENT WATER HEATER | T SW APARTMENT WATER HEATER | T NW APARTMENT WATER HEATER | T SE APARTMENT WATER HEATER | T NE APARTMENT WATER HEATER | T N1 APARTMENT WATER HEATER | T N2 APARTMENT WATER HEATER | T S1 APARTMENT WATER HEATER | T S2 APARTMENT WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW COOLING COIL | SPLIT GNW COOLING COIL | SPLIT OFFICE COOLING COIL | SPLIT GNE COOLING COIL | SPLIT GN1 COOLING COIL | SPLIT GN2 COOLING COIL | SPLIT GS1 COOLING COIL | SPLIT GS2 COOLING COIL | SPLIT MSW COOLING COIL | SPLIT MNW COOLING COIL | SPLIT MSE COOLING COIL | SPLIT MNE COOLING COIL | SPLIT MN1 COOLING COIL | SPLIT MN2 COOLING COIL | SPLIT MS1 COOLING COIL | SPLIT MS2 COOLING COIL | SPLIT TSW COOLING COIL | SPLIT TNW COOLING COIL | SPLIT TSE COOLING COIL | SPLIT TNE COOLING COIL | SPLIT TN1 COOLING COIL | SPLIT TN2 COOLING COIL | SPLIT TS1 COOLING COIL | SPLIT TS2 COOLING COIL |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:15 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | William R Fairchild WA USA TMY3 WMO#=727885 |
| Latitude [deg] | 48.12 |
| Longitude [deg] | -123.5 |
| Elevation [m] | 91.00 |
| Time Zone | -8.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 9.7532 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 8.6918 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 8.6918 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 4.7725 | 18.58 | 105.2565 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 4.7725 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 8.3333 | 31.67 | 8.6167 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 8.7250 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 4.7725 | 18.58 | 26.3141 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 9.7532 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 8.6918 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 4.7725 | 18.58 | 105.2565 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 4.7725 | 18.58 | 0.0000 | |
| Total | 3134.61 | 8.3333 | 15.84 | 8.6167 | |||||||
| Conditioned Total | 2823.98 | 8.7250 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 4.7725 | 9.29 | 26.3141 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 6.2575 | 41.91 | 7.1145 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 22-JUL-17:30 | 10-JAN-05:00 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 54764.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 17843.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 5231.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22609.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 6826.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 27586.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 80097.91 | 54764.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 54764.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 17843.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 4887.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 344.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | MiscPlug | 18441.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLift | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| ElevatorLightsFan | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 6826.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Water Heater | 27586.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 293.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 104.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 314.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 158.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1452.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 226.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 1515.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 3771.61 | 293.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 103.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 37.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 111.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 55.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 514.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 80.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 536.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1335.57 | 103.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 93.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 33.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 100.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 50.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 463.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 72.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 483.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1203.21 | 93.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.342774 |
| SPLIT GNW SUPPLY FAN | 0.281246 |
| SPLIT OFFICE SUPPLY FAN | 0.369200 |
| SPLIT GNE SUPPLY FAN | 0.242035 |
| SPLIT GN1 SUPPLY FAN | 0.227851 |
| SPLIT GN2 SUPPLY FAN | 0.226948 |
| SPLIT GS1 SUPPLY FAN | 0.290846 |
| SPLIT GS2 SUPPLY FAN | 0.292100 |
| SPLIT MSW SUPPLY FAN | 0.860018 |
| SPLIT MNW SUPPLY FAN | 0.748244 |
| SPLIT MSE SUPPLY FAN | 0.739065 |
| SPLIT MNE SUPPLY FAN | 0.630222 |
| SPLIT MN1 SUPPLY FAN | 0.577942 |
| SPLIT MN2 SUPPLY FAN | 0.575884 |
| SPLIT MS1 SUPPLY FAN | 0.700828 |
| SPLIT MS2 SUPPLY FAN | 0.698535 |
| SPLIT TSW SUPPLY FAN | 0.459022 |
| SPLIT TNW SUPPLY FAN | 0.414073 |
| SPLIT TSE SUPPLY FAN | 0.371235 |
| SPLIT TNE SUPPLY FAN | 0.326822 |
| SPLIT TN1 SUPPLY FAN | 0.316760 |
| SPLIT TN2 SUPPLY FAN | 0.313998 |
| SPLIT TS1 SUPPLY FAN | 0.364631 |
| SPLIT TS2 SUPPLY FAN | 0.361866 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.342774 |
| G NW APARTMENT DIRECT AIR | 0.281246 |
| OFFICE DIRECT AIR | 0.369200 |
| G NE APARTMENT DIRECT AIR | 0.242035 |
| G N1 APARTMENT DIRECT AIR | 0.227851 |
| G N2 APARTMENT DIRECT AIR | 0.226948 |
| G S1 APARTMENT DIRECT AIR | 0.290846 |
| G S2 APARTMENT DIRECT AIR | 0.292100 |
| M SW APARTMENT DIRECT AIR | 0.860018 |
| M NW APARTMENT DIRECT AIR | 0.748244 |
| M SE APARTMENT DIRECT AIR | 0.739065 |
| M NE APARTMENT DIRECT AIR | 0.630222 |
| M N1 APARTMENT DIRECT AIR | 0.577942 |
| M N2 APARTMENT DIRECT AIR | 0.575884 |
| M S1 APARTMENT DIRECT AIR | 0.700828 |
| M S2 APARTMENT DIRECT AIR | 0.698535 |
| T SW APARTMENT DIRECT AIR | 0.459022 |
| T NW APARTMENT DIRECT AIR | 0.414073 |
| T SE APARTMENT DIRECT AIR | 0.371235 |
| T NE APARTMENT DIRECT AIR | 0.326822 |
| T N1 APARTMENT DIRECT AIR | 0.316760 |
| T N2 APARTMENT DIRECT AIR | 0.313998 |
| T S1 APARTMENT DIRECT AIR | 0.364631 |
| T S2 APARTMENT DIRECT AIR | 0.361866 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.342774 | 0.342774 | 0.342774 | 0.342774 | 0.342774 | 0.342774 | 1.00 | 1.00 | 0.342774 |
| SPLIT GNW | 0.281246 | 0.281246 | 0.281246 | 0.281246 | 0.281246 | 0.281246 | 1.00 | 1.00 | 0.281246 |
| SPLIT OFFICE | 0.369200 | 0.369200 | 0.369200 | 0.369200 | 0.369200 | 0.369200 | 1.00 | 1.00 | 0.369200 |
| SPLIT GNE | 0.242035 | 0.242035 | 0.242035 | 0.242035 | 0.242035 | 0.242035 | 1.00 | 1.00 | 0.242035 |
| SPLIT GN1 | 0.227851 | 0.227851 | 0.227851 | 0.227851 | 0.227851 | 0.227851 | 1.00 | 1.000000 | 0.227851 |
| SPLIT GN2 | 0.226948 | 0.226948 | 0.226948 | 0.226948 | 0.226948 | 0.226948 | 1.00 | 1.00 | 0.226948 |
| SPLIT GS1 | 0.290846 | 0.290846 | 0.290846 | 0.290846 | 0.290846 | 0.290846 | 1.00 | 1.000000 | 0.290846 |
| SPLIT GS2 | 0.292100 | 0.292100 | 0.292100 | 0.292100 | 0.292100 | 0.292100 | 1.00 | 1.00 | 0.292100 |
| SPLIT MSW | 0.860018 | 0.860018 | 0.860018 | 0.860018 | 0.860018 | 0.860018 | 1.00 | 1.000000 | 0.860018 |
| SPLIT MNW | 0.748244 | 0.748244 | 0.748244 | 0.748244 | 0.748244 | 0.748244 | 1.00 | 1.00 | 0.748244 |
| SPLIT MSE | 0.739065 | 0.739065 | 0.739065 | 0.739065 | 0.739065 | 0.739065 | 1.00 | 1.000000 | 0.739065 |
| SPLIT MNE | 0.630222 | 0.630222 | 0.630222 | 0.630222 | 0.630222 | 0.630222 | 1.00 | 1.00 | 0.630222 |
| SPLIT MN1 | 0.577942 | 0.577942 | 0.577942 | 0.577942 | 0.577942 | 0.577942 | 1.00 | 1.00 | 0.577942 |
| SPLIT MN2 | 0.575884 | 0.575884 | 0.575884 | 0.575884 | 0.575884 | 0.575884 | 1.00 | 1.00 | 0.575884 |
| SPLIT MS1 | 0.700828 | 0.700828 | 0.700828 | 0.700828 | 0.700828 | 0.700828 | 1.00 | 1.00 | 0.700828 |
| SPLIT MS2 | 0.698535 | 0.698535 | 0.698535 | 0.698535 | 0.698535 | 0.698535 | 1.00 | 1.00 | 0.698535 |
| SPLIT TSW | 0.459022 | 0.459022 | 0.459022 | 0.459022 | 0.459022 | 0.459022 | 1.00 | 1.000000 | 0.459022 |
| SPLIT TNW | 0.414073 | 0.414073 | 0.414073 | 0.414073 | 0.414073 | 0.414073 | 1.00 | 1.00 | 0.414073 |
| SPLIT TSE | 0.371235 | 0.371235 | 0.371235 | 0.371235 | 0.371235 | 0.371235 | 1.00 | 1.00 | 0.371235 |
| SPLIT TNE | 0.326822 | 0.326822 | 0.326822 | 0.326822 | 0.326822 | 0.326822 | 1.00 | 1.00 | 0.326822 |
| SPLIT TN1 | 0.316760 | 0.316760 | 0.316760 | 0.316760 | 0.316760 | 0.316760 | 1.00 | 1.00 | 0.316760 |
| SPLIT TN2 | 0.313998 | 0.313998 | 0.313998 | 0.313998 | 0.313998 | 0.313998 | 1.00 | 1.00 | 0.313998 |
| SPLIT TS1 | 0.364631 | 0.364631 | 0.364631 | 0.364631 | 0.364631 | 0.364631 | 1.00 | 1.00 | 0.364631 |
| SPLIT TS2 | 0.361866 | 0.361866 | 0.361866 | 0.361866 | 0.361866 | 0.361866 | 1.00 | 1.000000 | 0.361866 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.342774 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.281246 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.369200 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.242035 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.227851 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.226948 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.290846 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.292100 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.860018 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.748244 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.739065 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.630222 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.577942 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.575884 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.700828 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.698535 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.459022 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.414073 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.371235 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.326822 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.316760 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.313998 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.364631 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.361866 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.342774 | 0.342774 | 0.342774 | 0.342774 | 5674.12 | 8544.99 | 40.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.281246 | 0.281246 | 0.281246 | 0.281246 | 4655.61 | 7152.78 | 40.00 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.369200 | 0.369200 | 0.369200 | 0.369200 | 6111.57 | 9512.42 | 40.00 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.242035 | 0.242035 | 0.242035 | 0.242035 | 4006.54 | 6265.60 | 40.00 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.227851 | 0.227851 | 0.227851 | 0.227851 | 3771.75 | 5944.65 | 40.00 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.226948 | 0.226948 | 0.226948 | 0.226948 | 3756.80 | 5924.22 | 40.00 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.290846 | 0.290846 | 0.290846 | 0.290846 | 4814.54 | 7370.04 | 40.00 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.292100 | 0.292100 | 0.292100 | 0.292100 | 4835.30 | 7398.41 | 40.00 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.860018 | 0.860018 | 0.860018 | 0.860018 | 14236.35 | 21037.92 | 40.00 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.748244 | 0.748244 | 0.748244 | 0.748244 | 12386.09 | 18508.54 | 40.00 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.739065 | 0.739065 | 0.739065 | 0.739065 | 12234.15 | 18301.13 | 40.00 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.630222 | 0.630222 | 0.630222 | 0.630222 | 10432.41 | 15838.12 | 40.00 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.577942 | 0.577942 | 0.577942 | 0.577942 | 9566.99 | 14655.12 | 40.00 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.575884 | 0.575884 | 0.575884 | 0.575884 | 9532.92 | 14608.56 | 40.00 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.700828 | 0.700828 | 0.700828 | 0.700828 | 11601.19 | 17435.84 | 40.00 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.698535 | 0.698535 | 0.698535 | 0.698535 | 11563.23 | 17383.96 | 40.00 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.459022 | 0.459022 | 0.459022 | 0.459022 | 7598.45 | 11175.51 | 40.00 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.414073 | 0.414073 | 0.414073 | 0.414073 | 6854.38 | 10158.29 | 40.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.371235 | 0.371235 | 0.371235 | 0.371235 | 6145.26 | 9189.15 | 40.00 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.326822 | 0.326822 | 0.326822 | 0.326822 | 5410.07 | 8184.09 | 40.00 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.316760 | 0.316760 | 0.316760 | 0.316760 | 5243.50 | 7956.33 | 40.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.313998 | 0.313998 | 0.313998 | 0.313998 | 5197.78 | 7893.84 | 40.00 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.364631 | 0.364631 | 0.364631 | 0.364631 | 6035.94 | 9039.64 | 40.00 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.361866 | 0.361866 | 0.361866 | 0.361866 | 5990.17 | 8977.07 | 40.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW COOLING COIL | 0.342774 | 5674.12 | 0.800655 |
| SPLIT GNW COOLING COIL | 0.281246 | 4655.61 | 0.800655 |
| SPLIT OFFICE COOLING COIL | 0.369200 | 6111.57 | 0.800655 |
| SPLIT GNE COOLING COIL | 0.242035 | 4006.54 | 0.800655 |
| SPLIT GN1 COOLING COIL | 0.227851 | 3771.75 | 0.800655 |
| SPLIT GN2 COOLING COIL | 0.226948 | 3756.80 | 0.800655 |
| SPLIT GS1 COOLING COIL | 0.290846 | 4814.54 | 0.800655 |
| SPLIT GS2 COOLING COIL | 0.292100 | 4835.30 | 0.800655 |
| SPLIT MSW COOLING COIL | 0.860018 | 14236.35 | 0.800655 |
| SPLIT MNW COOLING COIL | 0.748244 | 12386.09 | 0.800655 |
| SPLIT MSE COOLING COIL | 0.739065 | 12234.15 | 0.800655 |
| SPLIT MNE COOLING COIL | 0.630222 | 10432.41 | 0.800655 |
| SPLIT MN1 COOLING COIL | 0.577942 | 9566.99 | 0.800655 |
| SPLIT MN2 COOLING COIL | 0.575884 | 9532.92 | 0.800655 |
| SPLIT MS1 COOLING COIL | 0.700828 | 11601.19 | 0.800655 |
| SPLIT MS2 COOLING COIL | 0.698535 | 11563.23 | 0.800655 |
| SPLIT TSW COOLING COIL | 0.459022 | 7598.45 | 0.800655 |
| SPLIT TNW COOLING COIL | 0.414073 | 6854.38 | 0.800655 |
| SPLIT TSE COOLING COIL | 0.371235 | 6145.26 | 0.800655 |
| SPLIT TNE COOLING COIL | 0.326822 | 5410.07 | 0.800655 |
| SPLIT TN1 COOLING COIL | 0.316760 | 5243.50 | 0.800655 |
| SPLIT TN2 COOLING COIL | 0.313998 | 5197.78 | 0.800655 |
| SPLIT TS1 COOLING COIL | 0.364631 | 6035.94 | 0.800655 |
| SPLIT TS2 COOLING COIL | 0.361866 | 5990.17 | 0.800655 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW HEATING COIL | 8544.99 |
| SPLIT GNW HEATING COIL | 7152.78 |
| SPLIT OFFICE HEATING COIL | 9512.42 |
| SPLIT GNE HEATING COIL | 6265.60 |
| SPLIT GN1 HEATING COIL | 5944.65 |
| SPLIT GN2 HEATING COIL | 5924.22 |
| SPLIT GS1 HEATING COIL | 7370.04 |
| SPLIT GS2 HEATING COIL | 7398.41 |
| SPLIT MSW HEATING COIL | 21037.92 |
| SPLIT MNW HEATING COIL | 18508.54 |
| SPLIT MSE HEATING COIL | 18301.13 |
| SPLIT MNE HEATING COIL | 15838.12 |
| SPLIT MN1 HEATING COIL | 14655.12 |
| SPLIT MN2 HEATING COIL | 14608.56 |
| SPLIT MS1 HEATING COIL | 17435.84 |
| SPLIT MS2 HEATING COIL | 17383.96 |
| SPLIT TSW HEATING COIL | 11175.51 |
| SPLIT TNW HEATING COIL | 10158.29 |
| SPLIT TSE HEATING COIL | 9189.15 |
| SPLIT TNE HEATING COIL | 8184.09 |
| SPLIT TN1 HEATING COIL | 7956.33 |
| SPLIT TN2 HEATING COIL | 7893.84 |
| SPLIT TS1 HEATING COIL | 9039.64 |
| SPLIT TS2 HEATING COIL | 8977.07 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 9.30 | 6.70 | 4.10 | 4.20 | 4.20 | 5.90 | 9.00 | 10.00 | 13.30 | 15.00 | 15.70 | 13.40 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | William R Fairchild WA USA TMY3 WMO#=727885 | 48.12 | -123.50 | -8.00 | 91.00 | 100237 | 1.1914 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 9.23 | 11.60 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 9.753 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 16.423 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 8.692 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 15.362 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 105.256 | 0.000 | 0.000 | 0.000 | 0.000 | 110.029 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 4.772 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.772 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 860.710 | 9.753 | 181.220 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 860.710 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 694.381 | 7.868 | 277.753 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 694.381 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 370.628 | 4.772 | 88.667 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 370.628 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 72.668 | 0.823 | 29.067 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 72.668 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 2 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 3 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 4 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 7 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | G CORRIDOR_ELEVATORS_EQUIP | BLDG_ELEVATORS | G CORRIDOR | 77.66 | 4.2 | 8012.150 | 103.170 | 1916.782 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 961.458 | 4006.075 |
| 26 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_24_7 | G CORRIDOR | 77.66 | 4.2 | 162.000 | 2.086 | 38.756 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 162.000 | 162.000 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | G SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 2 | WaterHeater:Mixed | G NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 3 | WaterHeater:Mixed | G NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 4 | WaterHeater:Mixed | G N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 5 | WaterHeater:Mixed | G N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 6 | WaterHeater:Mixed | G S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 7 | WaterHeater:Mixed | G S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 8 | WaterHeater:Mixed | M SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 9 | WaterHeater:Mixed | M NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 10 | WaterHeater:Mixed | M SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 11 | WaterHeater:Mixed | M NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 12 | WaterHeater:Mixed | M N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 13 | WaterHeater:Mixed | M N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 14 | WaterHeater:Mixed | M S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 15 | WaterHeater:Mixed | M S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.498 | 0.7911 |
| 16 | WaterHeater:Mixed | T SW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 17 | WaterHeater:Mixed | T NW APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 18 | WaterHeater:Mixed | T SE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 19 | WaterHeater:Mixed | T NE APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 20 | WaterHeater:Mixed | T N1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 21 | WaterHeater:Mixed | T N2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 22 | WaterHeater:Mixed | T S1 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| 23 | WaterHeater:Mixed | T S2 APARTMENT WATER HEATER | 0.1892 | 14653.5 | 1.496 | 0.7729 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 5.696E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 5.696E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 3.333E-002 | 3.777E-004 | 2.271E-004 | 0.446 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 2.011E-002 | 2.278E-004 | 1.627E-004 | 0.269 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 5.696E-004 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 5.820E-003 | 7.494E-005 | 6.623E-005 | 8.852E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 4004.63085 | 4805.55702 | 0.28564 | 0.34277 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 1385.31593 | 1662.37912 | 6.03335E-002 | 7.24002E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3301.64175 | 3961.97010 | 0.23437 | 0.28125 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 1262.78324 | 1515.33989 | 5.49974E-002 | 6.59969E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4250.43714 | 5100.52457 | 0.30767 | 0.36920 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.39500 | 8.39928E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 1827.02976 | 2192.43571 | 7.95711E-002 | 9.54853E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | -4.30000 | 2.65759E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 2854.49383 | 3425.39259 | 0.20170 | 0.24204 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 1264.66993 | 1517.60392 | 5.50796E-002 | 6.60955E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 2693.43242 | 3232.11891 | 0.18988 | 0.22785 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 726.73454 | 872.08145 | 3.16512E-002 | 3.79815E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 2683.18889 | 3219.82666 | 0.18912 | 0.22695 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 726.79308 | 872.15170 | 3.16538E-002 | 3.79845E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3411.15388 | 4093.38465 | 0.24237 | 0.29085 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 850.92481 | 1021.10978 | 3.70597E-002 | 4.44717E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3425.36273 | 4110.43528 | 0.24342 | 0.29210 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 859.46412 | 1031.35695 | 3.74316E-002 | 4.49180E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 9998.38615 | 11998.06338 | 0.71668 | 0.86002 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 2126.02499 | 2551.22999 | 9.25916E-002 | 0.11111 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 8722.20615 | 10466.64738 | 0.62354 | 0.74824 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 1833.22554 | 2199.87064 | 7.98412E-002 | 9.58094E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 8617.53244 | 10341.03892 | 0.61589 | 0.73907 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 2130.88101 | 2557.05721 | 9.28031E-002 | 0.11136 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 7377.33697 | 8852.80437 | 0.52518 | 0.63022 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 1838.13348 | 2205.76017 | 8.00550E-002 | 9.60659E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 6778.89624 | 8134.67548 | 0.48162 | 0.57794 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 816.18560 | 979.42272 | 3.55470E-002 | 5.19091E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 6755.46882 | 8106.56258 | 0.47990 | 0.57588 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 816.32104 | 979.58525 | 3.55529E-002 | 5.19091E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 8182.72220 | 9819.26664 | 0.58402 | 0.70083 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 1101.42531 | 1321.71037 | 4.79691E-002 | 5.75629E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 8156.67585 | 9788.01102 | 0.58211 | 0.69853 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 1101.55780 | 1321.86936 | 4.79749E-002 | 5.75699E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5333.97877 | 6400.77453 | 0.38252 | 0.45902 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 2008.69795 | 2410.43754 | 8.74812E-002 | 0.10498 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 4820.21883 | 5784.26259 | 0.34506 | 0.41407 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 1849.75792 | 2219.70950 | 8.05606E-002 | 9.66728E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4330.58931 | 5196.70717 | 0.30936 | 0.37124 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 2012.55866 | 2415.07039 | 8.76494E-002 | 0.10518 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 3824.28925 | 4589.14710 | 0.27235 | 0.32682 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 1853.67741 | 2224.41290 | 8.07313E-002 | 9.68776E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 3709.91756 | 4451.90107 | 0.26397 | 0.31676 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 1257.74152 | 1509.28982 | 5.47778E-002 | 6.57334E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 3678.56614 | 4414.27937 | 0.26166 | 0.31400 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 1257.85893 | 1509.43072 | 5.47829E-002 | 6.57395E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4255.07852 | 5106.09422 | 0.30386 | 0.36463 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 1417.26839 | 1700.72207 | 6.17244E-002 | 7.40693E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4223.53924 | 5068.24709 | 0.30155 | 0.36187 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 22.85100 | 8.40154E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 1417.38278 | 1700.85934 | 6.17294E-002 | 7.40753E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | -4.30000 | 2.65759E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4576.23 | 0.34277 | 0.34277 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 2427.38 | 7.24002E-002 | 7.24002E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 3742.02 | 0.28125 | 0.28125 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 2282.49 | 6.59969E-002 | 6.59969E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 4811.79 | 0.36920 | 0.36920 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 3319.22 | 9.54853E-002 | 9.54853E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 3210.60 | 0.24204 | 0.24204 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 2284.72 | 6.60955E-002 | 6.60955E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3018.91 | 0.22785 | 0.22785 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 1648.60 | 3.79815E-002 | 3.79815E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3006.62 | 0.22695 | 0.22695 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 1648.67 | 3.79845E-002 | 3.79845E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 3872.59 | 0.29085 | 0.29085 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 1795.46 | 4.44717E-002 | 4.44717E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 3889.43 | 0.29210 | 0.29210 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 1805.55 | 4.49180E-002 | 4.49180E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 11513.81 | 0.86002 | 0.86002 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 4092.49 | 0.11111 | 0.11111 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 10000.74 | 0.74824 | 0.74824 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 3746.27 | 9.58094E-002 | 9.58094E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 9876.38 | 0.73907 | 0.73907 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 4098.23 | 0.11136 | 0.11136 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 8403.34 | 0.63022 | 0.63022 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 3752.07 | 9.60659E-002 | 9.60659E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 7693.51 | 0.57794 | 0.57794 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 2752.96 | 5.19091E-002 | 5.19091E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 7665.65 | 0.57588 | 0.57588 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 2752.96 | 5.19091E-002 | 5.19091E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:00:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9359.40 | 0.70083 | 0.70083 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 2880.89 | 5.75629E-002 | 5.75629E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9328.42 | 0.69853 | 0.69853 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 2881.04 | 5.75699E-002 | 5.75699E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6151.61 | 0.45902 | 0.45902 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 3164.53 | 0.10498 | 0.10498 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 5543.33 | 0.41407 | 0.41407 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 2976.59 | 9.66728E-002 | 9.66728E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 4963.51 | 0.37124 | 0.37124 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 3169.10 | 0.10518 | 0.10518 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 4362.68 | 0.32682 | 0.32682 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 2981.23 | 9.68776E-002 | 9.68776E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 4226.62 | 0.31676 | 0.31676 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 2276.53 | 6.57334E-002 | 6.57334E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 4189.32 | 0.31400 | 0.31400 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 2276.67 | 6.57395E-002 | 6.57395E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 4874.06 | 0.36463 | 0.36463 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 2465.16 | 7.40693E-002 | 7.40693E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 4836.66 | 0.36187 | 0.36187 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 2465.30 | 7.40753E-002 | 7.40753E-002 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34277 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.28125 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36920 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.24204 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.22785 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.22695 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29085 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29210 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.86002 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.74824 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.73907 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.63022 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57794 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57588 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.70083 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.69853 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.45902 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.41407 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37124 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.32682 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31676 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31400 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36463 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36187 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34277 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34277 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34277 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34277 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34277 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.34277 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.28125 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.28125 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.28125 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.28125 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.28125 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.28125 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36920 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36920 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36920 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36920 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36920 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.36920 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.24204 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.24204 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.24204 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.24204 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.24204 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.24204 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.22785 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.22785 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.22785 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.22785 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.22785 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.22785 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.22695 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.22695 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.22695 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.22695 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.22695 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.22695 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29085 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29085 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29085 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29085 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29085 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29085 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29210 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29210 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29210 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29210 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29210 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.29210 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.86002 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.86002 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.86002 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.86002 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.86002 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.86002 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.74824 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.74824 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.74824 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.74824 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.74824 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.74824 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.73907 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.73907 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.73907 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.73907 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.73907 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.73907 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.63022 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.63022 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.63022 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.63022 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.63022 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.63022 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57794 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57794 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57794 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57794 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57794 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.57794 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57588 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57588 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57588 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57588 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57588 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.57588 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.70083 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.70083 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.70083 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.70083 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.70083 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.70083 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.69853 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.69853 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.69853 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.69853 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.69853 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.69853 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.45902 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.45902 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.45902 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.45902 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.45902 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.45902 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.41407 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.41407 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.41407 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.41407 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.41407 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.41407 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37124 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37124 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37124 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37124 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37124 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.37124 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.32682 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.32682 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.32682 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.32682 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.32682 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.32682 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31676 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31676 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31676 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31676 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31676 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31676 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31400 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31400 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31400 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31400 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31400 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31400 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36463 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36463 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36463 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36463 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36463 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36463 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36187 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36187 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36187 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36187 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36187 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.36187 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.34277 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.28125 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.36920 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.24204 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.22785 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.22695 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.29085 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.29210 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.86002 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.74824 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.73907 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.63022 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.57794 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.57588 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.70083 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.69853 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.45902 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.41407 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.37124 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.32682 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.31676 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.31400 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.36463 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.36187 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34277 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34277 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34277 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34277 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34277 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5674.12202 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8544.99425 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 366 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34277 |
| 367 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34277 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5674.12202 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 370 | Coil:Heating:Fuel | SPLIT GSW HEATING COIL | Design Size Nominal Capacity [W] | 8544.99425 |
| 371 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.28125 |
| 372 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 373 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.28125 |
| 374 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28125 |
| 375 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28125 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28125 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4655.61414 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7152.78241 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 381 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.28125 |
| 382 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28125 |
| 383 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4655.61414 |
| 384 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 385 | Coil:Heating:Fuel | SPLIT GNW HEATING COIL | Design Size Nominal Capacity [W] | 7152.78241 |
| 386 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36920 |
| 387 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 388 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36920 |
| 389 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36920 |
| 390 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36920 |
| 391 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36920 |
| 392 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6111.56854 |
| 393 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9512.42440 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 396 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36920 |
| 397 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36920 |
| 398 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6111.56854 |
| 399 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 400 | Coil:Heating:Fuel | SPLIT OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 9512.42440 |
| 401 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.24204 |
| 402 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 403 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.24204 |
| 404 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.24204 |
| 405 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.24204 |
| 406 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.24204 |
| 407 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4006.54355 |
| 408 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6265.59559 |
| 409 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 410 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 411 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.24204 |
| 412 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.24204 |
| 413 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4006.54355 |
| 414 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 415 | Coil:Heating:Fuel | SPLIT GNE HEATING COIL | Design Size Nominal Capacity [W] | 6265.59559 |
| 416 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.22785 |
| 417 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.22785 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.22785 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.22785 |
| 421 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.22785 |
| 422 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 3771.74933 |
| 423 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 5944.64922 |
| 424 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 425 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 426 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.22785 |
| 427 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.22785 |
| 428 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 3771.74933 |
| 429 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 430 | Coil:Heating:Fuel | SPLIT GN1 HEATING COIL | Design Size Nominal Capacity [W] | 5944.64922 |
| 431 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.22695 |
| 432 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.22695 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.22695 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.22695 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.22695 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 3756.80248 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 5924.21909 |
| 439 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 440 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 441 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.22695 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.22695 |
| 443 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 3756.80248 |
| 444 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 445 | Coil:Heating:Fuel | SPLIT GN2 HEATING COIL | Design Size Nominal Capacity [W] | 5924.21909 |
| 446 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29085 |
| 447 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29085 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29085 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29085 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29085 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4814.53694 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7370.03626 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 456 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29085 |
| 457 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29085 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4814.53694 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 460 | Coil:Heating:Fuel | SPLIT GS1 HEATING COIL | Design Size Nominal Capacity [W] | 7370.03626 |
| 461 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29210 |
| 462 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 463 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29210 |
| 464 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29210 |
| 465 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29210 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29210 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4835.29722 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7398.41274 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 471 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29210 |
| 472 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29210 |
| 473 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4835.29722 |
| 474 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 475 | Coil:Heating:Fuel | SPLIT GS2 HEATING COIL | Design Size Nominal Capacity [W] | 7398.41274 |
| 476 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.86002 |
| 477 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 478 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.86002 |
| 479 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.86002 |
| 480 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.86002 |
| 481 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.86002 |
| 482 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14236.34928 |
| 483 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 21037.91646 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 486 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.86002 |
| 487 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.86002 |
| 488 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14236.34928 |
| 489 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 490 | Coil:Heating:Fuel | SPLIT MSW HEATING COIL | Design Size Nominal Capacity [W] | 21037.91646 |
| 491 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.74824 |
| 492 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 493 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.74824 |
| 494 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.74824 |
| 495 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.74824 |
| 496 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.74824 |
| 497 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12386.09499 |
| 498 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18508.54491 |
| 499 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 500 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 501 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.74824 |
| 502 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.74824 |
| 503 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12386.09499 |
| 504 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 505 | Coil:Heating:Fuel | SPLIT MNW HEATING COIL | Design Size Nominal Capacity [W] | 18508.54491 |
| 506 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.73907 |
| 507 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.73907 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.73907 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.73907 |
| 511 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.73907 |
| 512 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12234.15067 |
| 513 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 18301.13474 |
| 514 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 515 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 516 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.73907 |
| 517 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.73907 |
| 518 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12234.15067 |
| 519 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 520 | Coil:Heating:Fuel | SPLIT MSE HEATING COIL | Design Size Nominal Capacity [W] | 18301.13474 |
| 521 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.63022 |
| 522 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.63022 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.63022 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.63022 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.63022 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10432.40962 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 15838.12297 |
| 529 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 530 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 531 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.63022 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.63022 |
| 533 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10432.40962 |
| 534 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 535 | Coil:Heating:Fuel | SPLIT MNE HEATING COIL | Design Size Nominal Capacity [W] | 15838.12297 |
| 536 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57794 |
| 537 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57794 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57794 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57794 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57794 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9566.99119 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 14655.11877 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 546 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57794 |
| 547 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57794 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9566.99119 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 550 | Coil:Heating:Fuel | SPLIT MN1 HEATING COIL | Design Size Nominal Capacity [W] | 14655.11877 |
| 551 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57588 |
| 552 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 553 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57588 |
| 554 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57588 |
| 555 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57588 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57588 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 9532.92484 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 14608.55506 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 561 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57588 |
| 562 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57588 |
| 563 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 9532.92484 |
| 564 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 565 | Coil:Heating:Fuel | SPLIT MN2 HEATING COIL | Design Size Nominal Capacity [W] | 14608.55506 |
| 566 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.70083 |
| 567 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 568 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.70083 |
| 569 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.70083 |
| 570 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.70083 |
| 571 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70083 |
| 572 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11601.19229 |
| 573 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17435.84294 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 576 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.70083 |
| 577 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.70083 |
| 578 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11601.19229 |
| 579 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 580 | Coil:Heating:Fuel | SPLIT MS1 HEATING COIL | Design Size Nominal Capacity [W] | 17435.84294 |
| 581 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.69853 |
| 582 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 583 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.69853 |
| 584 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.69853 |
| 585 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.69853 |
| 586 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.69853 |
| 587 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11563.23302 |
| 588 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 17383.95725 |
| 589 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 590 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 591 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.69853 |
| 592 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69853 |
| 593 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11563.23302 |
| 594 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 595 | Coil:Heating:Fuel | SPLIT MS2 HEATING COIL | Design Size Nominal Capacity [W] | 17383.95725 |
| 596 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.45902 |
| 597 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.45902 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.45902 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.45902 |
| 601 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.45902 |
| 602 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7598.44842 |
| 603 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 11175.51203 |
| 604 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 605 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 606 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.45902 |
| 607 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.45902 |
| 608 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7598.44842 |
| 609 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 610 | Coil:Heating:Fuel | SPLIT TSW HEATING COIL | Design Size Nominal Capacity [W] | 11175.51203 |
| 611 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.41407 |
| 612 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.41407 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.41407 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.41407 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.41407 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6854.37928 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 10158.28748 |
| 619 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 620 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 621 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.41407 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.41407 |
| 623 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6854.37928 |
| 624 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 625 | Coil:Heating:Fuel | SPLIT TNW HEATING COIL | Design Size Nominal Capacity [W] | 10158.28748 |
| 626 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37124 |
| 627 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37124 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37124 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37124 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37124 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6145.25872 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9189.14930 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 636 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37124 |
| 637 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37124 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6145.25872 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 640 | Coil:Heating:Fuel | SPLIT TSE HEATING COIL | Design Size Nominal Capacity [W] | 9189.14930 |
| 641 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.32682 |
| 642 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 643 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.32682 |
| 644 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.32682 |
| 645 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.32682 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.32682 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5410.06561 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8184.09282 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 651 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.32682 |
| 652 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32682 |
| 653 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5410.06561 |
| 654 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 655 | Coil:Heating:Fuel | SPLIT TNE HEATING COIL | Design Size Nominal Capacity [W] | 8184.09282 |
| 656 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31676 |
| 657 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 658 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31676 |
| 659 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31676 |
| 660 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31676 |
| 661 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31676 |
| 662 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5243.49517 |
| 663 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7956.33222 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 666 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31676 |
| 667 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31676 |
| 668 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5243.49517 |
| 669 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 670 | Coil:Heating:Fuel | SPLIT TN1 HEATING COIL | Design Size Nominal Capacity [W] | 7956.33222 |
| 671 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31400 |
| 672 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 673 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31400 |
| 674 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31400 |
| 675 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31400 |
| 676 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31400 |
| 677 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5197.77885 |
| 678 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7893.84454 |
| 679 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 680 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 681 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31400 |
| 682 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31400 |
| 683 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5197.77885 |
| 684 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 685 | Coil:Heating:Fuel | SPLIT TN2 HEATING COIL | Design Size Nominal Capacity [W] | 7893.84454 |
| 686 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36463 |
| 687 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36463 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36463 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36463 |
| 691 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36463 |
| 692 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6035.94249 |
| 693 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9039.63854 |
| 694 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 695 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 696 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36463 |
| 697 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36463 |
| 698 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6035.94249 |
| 699 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 700 | Coil:Heating:Fuel | SPLIT TS1 HEATING COIL | Design Size Nominal Capacity [W] | 9039.63854 |
| 701 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36187 |
| 702 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36187 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36187 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36187 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36187 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5990.16614 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8977.06763 |
| 709 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 710 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 711 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36187 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36187 |
| 713 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5990.16614 |
| 714 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80066 |
| 715 | Coil:Heating:Fuel | SPLIT TS2 HEATING COIL | Design Size Nominal Capacity [W] | 8977.06763 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW COOLING COIL | 5405.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW COOLING COIL | 4435.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE COOLING COIL | 5822.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE COOLING COIL | 3816.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 COOLING COIL | 3593.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 COOLING COIL | 3578.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 COOLING COIL | 4586.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 COOLING COIL | 4606.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW COOLING COIL | 13562.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW COOLING COIL | 11799.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE COOLING COIL | 11655.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE COOLING COIL | 9938.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 COOLING COIL | 9114.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 COOLING COIL | 9081.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 COOLING COIL | 11052.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 COOLING COIL | 11015.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW COOLING COIL | 7238.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW COOLING COIL | 6529.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE COOLING COIL | 5854.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE COOLING COIL | 5153.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 COOLING COIL | 4995.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 COOLING COIL | 4951.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 COOLING COIL | 5750.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 COOLING COIL | 5706.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.210 | 0.200 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.752 | 0.676 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.125 | 0.121 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.761 | 0.683 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.098 | 0.943 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.098 | 0.943 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.752 | 0.676 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 4.061E-002 | 4.021E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.761 | 0.683 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.3972_SHGC_0.4 | N/A | 2.257 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9996753044E-008 | 1.6208845509E-007 | Pass | Pass | 0.3311003518 | 1.0414034190 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 9.4208487061E-008 | 6.9641616040E-007 | Pass | Pass | 2.2199682012E-002 | 2.6566264071E-002 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 2.3734128629E-002 | 1.9748544317E-002 | Pass | Pass | 2.4721128913E-002 | 2.4716548206E-002 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 8.2571670439E-008 | 5.9997360187E-007 | Pass | Pass | 2.6002935044E-002 | 2.6839152387E-002 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.2267952779E-008 | 2.4742123092E-007 | Pass | Pass | 6.9430265519E-002 | 0.1386433941 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.2036385766E-008 | 2.4566863618E-007 | Pass | Pass | 7.0922047653E-002 | 0.1442023918 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.6949649954E-004 | 2.1286053829E-003 | Pass | Pass | 5.5749002499E-002 | 7.1692730039E-002 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.1685043740E-009 | 4.7092950048E-008 | Pass | Pass | 0.4867008497 | 3.5111702928 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 8.1538475770E-003 | 1.8326022383E-002 | Pass | Pass | 9.1777910300E-002 | 0.2351324655 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.3708239804E-008 | 2.5737608991E-007 | Pass | Pass | 0.5274308393 | 3.4786174740 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.0937070122E-002 | 2.0727727391E-002 | Pass | Pass | 9.4449717587E-002 | 0.3811057756 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.7773355405E-008 | 1.2543702279E-007 | Pass | Pass | 0.2371229043 | 0.5205914237 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6699212791E-008 | 1.7868383202E-007 | Pass | Pass | 5.2605870345E-002 | 7.4984962644E-002 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6963689528E-008 | 1.8053233781E-007 | Pass | Pass | 5.2026865471E-002 | 7.4189688446E-002 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9649360067E-002 | 2.0816367620E-002 | Pass | Pass | 9.1459850967E-003 | 1.5979521499E-002 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.0012778199E-002 | 2.1009468107E-002 | Pass | Pass | 9.7668303042E-003 | 2.0853049734E-002 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.3626822690E-003 | 5.1514411097E-003 | Pass | Pass | 0.2875306744 | 1.1621866140 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 1.5649167959E-007 | 1.1225842926E-006 | Pass | Pass | 2.5512890866E-002 | 2.5706800856E-002 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 6.0753246251E-003 | 1.7115468562E-002 | Pass | Pass | 0.1570494579 | 0.4851921878 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.3517811352E-007 | 9.4203506452E-007 | Pass | Pass | 2.9885751485E-002 | 2.8631942649E-002 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 7.4826233752E-008 | 5.5674024914E-007 | Pass | Pass | 3.6076597682E-002 | 4.0243716420E-002 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 7.4623590122E-008 | 5.5499674443E-007 | Pass | Pass | 3.6629832203E-002 | 4.0390760825E-002 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1053799065E-002 | 2.4640798036E-002 | Pass | Pass | 0.1344280075 | 0.3693688365 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.1489104019E-002 | 2.5371144325E-002 | Pass | Pass | 0.1413086601 | 0.4424677143 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 1.2247195571E-002 | 1.1107688862E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.1784809823 | 0.5682828628 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 5.0748701557E-003 | 4.4264737849E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1661.78 | 111.29 | 0.00 | 18.46 | 217.77 | 2009.32 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | -4.30 | 0.00 | -4.30 | Wetbulb [C] | 1.20 | 110.00 |
| WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.40 | 9.10 | 17.00 | Wetbulb [C] | 2.10 | 90.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 0.00 | 0 | |||
| Feb | 42.00 | 35 | |||
| Mar | 0.00 | 0 | |||
| Apr | 0.00 | 0 | |||
| May | 40.00 | 22 | |||
| Jun | 4.00 | 8 | |||
| Jul | 5.00 | 4 | |||
| Aug | 7.00 | 8 | |||
| Sep | 17.00 | 10 | |||
| Oct | 50.00 | 49 | |||
| Nov | 69.00 | 59 | |||
| Dec | 95.00 | 53 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.203 | 0.210 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.123 | 0.125 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.30 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.943 | 1.098 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.30 | 0.221 | 0.228 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.676 | 0.752 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.040 | 0.041 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.683 | 0.761 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.257 | 0.401 | 0.402 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.257 | 0.401 | 0.402 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.3972_SHGC_0.4 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.257 | 0.401 | 0.402 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.3972_SHGC_0.4 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.257 | 0.401 | 0.402 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.3972_SHGC_0.4 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.257 | 0.401 | 0.402 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.3972_SHGC_0.4 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.257 | 0.401 | 0.402 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.3972_SHGC_0.4 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.257 | 0.401 | 0.402 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 2.257 | 0.401 | 0.402 | |||||||||||||||||
| North Total or Average | 112.97 | 2.257 | 0.401 | 0.402 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 2.257 | 0.401 | 0.402 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 9.7532 | 88.25 | 860.71 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 7.40 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 7.8684 | 176.50 | 1388.76 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 2.63 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 7.8684 | 88.25 | 694.38 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.32 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 4.7725 | 155.32 | 741.26 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 23.38 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 4.7725 | 77.66 | 370.63 | LightsWired | LTG_SCH_CORRIDOR | 168.00 | 168.00 | 168.00 | 0.0000 | N | 11.69 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.8234 | 176.50 | 145.34 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.28 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.8234 | 88.25 | 72.67 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.14 |
| Interior Lighting Total | 4.4498 | 5870.34 | 26121.74 | 75.91 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 3183.33 | AstronomicalClock | - | 83.54 | 83.54 | 49.92 | |
| Exterior Lighting Total | 3183.33 | 49.92 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5674.12 | 4543.02 | 1131.11 | 0.80 | 3.91 | |||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4655.61 | 3727.54 | 928.07 | 0.80 | 3.91 | |||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6111.57 | 4893.26 | 1218.31 | 0.80 | 3.91 | |||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4006.54 | 3207.86 | 798.68 | 0.80 | 3.91 | |||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3771.75 | 3019.87 | 751.88 | 0.80 | 3.91 | |||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3756.80 | 3007.90 | 748.90 | 0.80 | 3.91 | |||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4814.54 | 3854.78 | 959.75 | 0.80 | 3.91 | |||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4835.30 | 3871.41 | 963.89 | 0.80 | 3.91 | |||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14236.35 | 11398.41 | 2837.94 | 0.80 | 3.91 | |||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12386.09 | 9916.99 | 2469.10 | 0.80 | 3.91 | |||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12234.15 | 9795.34 | 2438.81 | 0.80 | 3.91 | |||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10432.41 | 8352.76 | 2079.65 | 0.80 | 3.91 | |||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9566.99 | 7659.86 | 1907.13 | 0.80 | 3.91 | |||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9532.92 | 7632.59 | 1900.34 | 0.80 | 3.91 | |||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11601.19 | 9288.56 | 2312.64 | 0.80 | 3.91 | |||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11563.23 | 9258.16 | 2305.07 | 0.80 | 3.91 | |||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7598.45 | 6083.74 | 1514.71 | 0.80 | 3.91 | |||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6854.38 | 5487.99 | 1366.38 | 0.80 | 3.91 | |||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6145.26 | 4920.23 | 1225.03 | 0.80 | 3.91 | |||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5410.07 | 4331.60 | 1078.47 | 0.80 | 3.91 | |||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5243.50 | 4198.23 | 1045.26 | 0.80 | 3.91 | |||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5197.78 | 4161.63 | 1036.15 | 0.80 | 3.91 | |||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6035.94 | 4832.71 | 1203.23 | 0.80 | 3.91 | |||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5990.17 | 4796.06 | 1194.11 | 0.80 | 3.91 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW COOLING COIL | 5405.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNW COOLING COIL | 4435.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT OFFICE COOLING COIL | 5822.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GNE COOLING COIL | 3816.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN1 COOLING COIL | 3593.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GN2 COOLING COIL | 3578.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS1 COOLING COIL | 4586.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT GS2 COOLING COIL | 4606.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSW COOLING COIL | 13562.4 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNW COOLING COIL | 11799.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MSE COOLING COIL | 11655.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MNE COOLING COIL | 9938.5 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN1 COOLING COIL | 9114.1 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MN2 COOLING COIL | 9081.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS1 COOLING COIL | 11052.0 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT MS2 COOLING COIL | 11015.8 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSW COOLING COIL | 7238.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNW COOLING COIL | 6529.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TSE COOLING COIL | 5854.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TNE COOLING COIL | 5153.9 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN1 COOLING COIL | 4995.3 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TN2 COOLING COIL | 4951.7 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS1 COOLING COIL | 5750.2 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 | |
| SPLIT TS2 COOLING COIL | 5706.6 | 3.13 | 10.67 | 11.09 | 10.49 | 10.38 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:Fuel | 8544.99 | 0.80 | |
| SPLIT GNW HEATING COIL | Coil:Heating:Fuel | 7152.78 | 0.80 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:Fuel | 9512.42 | 0.80 | |
| SPLIT GNE HEATING COIL | Coil:Heating:Fuel | 6265.60 | 0.80 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:Fuel | 5944.65 | 0.80 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:Fuel | 5924.22 | 0.80 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:Fuel | 7370.04 | 0.80 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:Fuel | 7398.41 | 0.80 | |
| SPLIT MSW HEATING COIL | Coil:Heating:Fuel | 21037.92 | 0.80 | |
| SPLIT MNW HEATING COIL | Coil:Heating:Fuel | 18508.54 | 0.80 | |
| SPLIT MSE HEATING COIL | Coil:Heating:Fuel | 18301.13 | 0.80 | |
| SPLIT MNE HEATING COIL | Coil:Heating:Fuel | 15838.12 | 0.80 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:Fuel | 14655.12 | 0.80 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:Fuel | 14608.56 | 0.80 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:Fuel | 17435.84 | 0.80 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:Fuel | 17383.96 | 0.80 | |
| SPLIT TSW HEATING COIL | Coil:Heating:Fuel | 11175.51 | 0.80 | |
| SPLIT TNW HEATING COIL | Coil:Heating:Fuel | 10158.29 | 0.80 | |
| SPLIT TSE HEATING COIL | Coil:Heating:Fuel | 9189.15 | 0.80 | |
| SPLIT TNE HEATING COIL | Coil:Heating:Fuel | 8184.09 | 0.80 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:Fuel | 7956.33 | 0.80 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:Fuel | 7893.84 | 0.80 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:Fuel | 9039.64 | 0.80 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:Fuel | 8977.07 | 0.80 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.05 | 40.01 | 770.84 | 1.00 | 4.13 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 233.69 | 0.03 | 20.01 | 770.84 | 1.00 | 7.36 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 383.94 | 1120.11 | 1.00 | 1.81 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 315.03 | 1120.11 | 1.00 | 1.94 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 413.54 | 1120.11 | 1.00 | 1.76 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 271.11 | 1120.11 | 1.00 | 2.06 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 255.22 | 1120.11 | 1.00 | 2.12 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 254.21 | 1120.11 | 1.00 | 2.12 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 325.78 | 1120.11 | 1.00 | 1.92 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 327.18 | 1120.11 | 1.00 | 1.92 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.86 | 963.31 | 1120.11 | 1.00 | 1.41 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.75 | 838.11 | 1120.11 | 1.00 | 1.45 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.74 | 827.83 | 1120.11 | 1.00 | 1.46 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.63 | 705.92 | 1120.11 | 1.00 | 1.51 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 647.36 | 1120.11 | 1.00 | 1.54 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 645.05 | 1120.11 | 1.00 | 1.55 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.70 | 785.00 | 1120.11 | 1.00 | 1.48 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.70 | 782.43 | 1120.11 | 1.00 | 1.48 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.46 | 514.15 | 1120.11 | 1.00 | 1.65 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.41 | 463.81 | 1120.11 | 1.00 | 1.70 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 415.82 | 1120.11 | 1.00 | 1.76 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 366.08 | 1120.11 | 1.00 | 1.84 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 354.80 | 1120.11 | 1.00 | 1.86 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 351.71 | 1120.11 | 1.00 | 1.86 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 408.43 | 1120.11 | 1.00 | 1.77 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 405.33 | 1120.11 | 1.00 | 1.77 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| None |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.79 |
| T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
| T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 1.50 | 0.77 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 4004.63 | 4805.56 | 54.45 | 0.286 | 0.343 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 22.85 | 0.00840 | 0.026 | 0.00 |
| G NW APARTMENT | 3301.64 | 3961.97 | 44.90 | 0.234 | 0.281 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 22.85 | 0.00840 | 0.026 | 0.00 |
| OFFICE | 4250.44 | 5100.52 | 57.80 | 0.308 | 0.369 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.90 | 23.90 | 0.00801 | 21.39 | 0.00840 | 0.038 | 0.00 |
| G NE APARTMENT | 2854.49 | 3425.39 | 38.81 | 0.202 | 0.242 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00815 | 22.85 | 0.00840 | 0.026 | 0.00 |
| G N1 APARTMENT | 2693.43 | 3232.12 | 36.62 | 0.190 | 0.228 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00817 | 22.85 | 0.00840 | 0.026 | 0.00 |
| G N2 APARTMENT | 2683.19 | 3219.83 | 36.49 | 0.189 | 0.227 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00818 | 22.85 | 0.00840 | 0.026 | 0.00 |
| G S1 APARTMENT | 3411.15 | 4093.38 | 46.38 | 0.242 | 0.291 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00817 | 22.85 | 0.00840 | 0.026 | 0.00 |
| G S2 APARTMENT | 3425.36 | 4110.44 | 46.58 | 0.243 | 0.292 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00817 | 22.85 | 0.00840 | 0.026 | 0.00 |
| M SW APARTMENT | 9998.39 | 11998.06 | 135.96 | 0.717 | 0.860 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00809 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M NW APARTMENT | 8722.21 | 10466.65 | 118.60 | 0.624 | 0.748 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00808 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M SE APARTMENT | 8617.53 | 10341.04 | 117.18 | 0.616 | 0.739 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00811 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M NE APARTMENT | 7377.34 | 8852.80 | 100.32 | 0.525 | 0.630 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00811 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M N1 APARTMENT | 6778.90 | 8134.68 | 92.18 | 0.482 | 0.578 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M N2 APARTMENT | 6755.47 | 8106.56 | 91.86 | 0.480 | 0.576 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00813 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M S1 APARTMENT | 8182.72 | 9819.27 | 111.27 | 0.584 | 0.701 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 22.85 | 0.00840 | 0.052 | 0.00 |
| M S2 APARTMENT | 8156.68 | 9788.01 | 110.91 | 0.582 | 0.699 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 22.85 | 0.00840 | 0.052 | 0.00 |
| T SW APARTMENT | 5333.98 | 6400.77 | 72.53 | 0.383 | 0.459 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00808 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T NW APARTMENT | 4820.22 | 5784.26 | 65.54 | 0.345 | 0.414 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00807 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T SE APARTMENT | 4330.59 | 5196.71 | 58.89 | 0.309 | 0.371 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T NE APARTMENT | 3824.29 | 4589.15 | 52.00 | 0.272 | 0.327 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T N1 APARTMENT | 3709.92 | 4451.90 | 50.45 | 0.264 | 0.317 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T N2 APARTMENT | 3678.57 | 4414.28 | 50.02 | 0.262 | 0.314 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T S1 APARTMENT | 4255.08 | 5106.09 | 57.86 | 0.304 | 0.365 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 22.85 | 0.00840 | 0.026 | 0.00 |
| T S2 APARTMENT | 4223.54 | 5068.25 | 57.43 | 0.302 | 0.362 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00811 | 22.85 | 0.00840 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 1385.32 | 1662.38 | 18.84 | 0.060 | 0.072 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00779 | -4.30 | 0.00266 | 0.026 | 0.00 |
| G NW APARTMENT | 1262.78 | 1515.34 | 17.17 | 0.055 | 0.066 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00797 | -4.30 | 0.00266 | 0.026 | 0.00 |
| OFFICE | 1827.03 | 2192.44 | 24.84 | 0.080 | 0.095 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00784 | -4.30 | 0.00266 | 0.038 | 0.00 |
| G NE APARTMENT | 1264.67 | 1517.60 | 17.20 | 0.055 | 0.066 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00797 | -4.30 | 0.00266 | 0.026 | 0.00 |
| G N1 APARTMENT | 726.73 | 872.08 | 9.88 | 0.032 | 0.038 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00814 | -4.30 | 0.00266 | 0.026 | 0.00 |
| G N2 APARTMENT | 726.79 | 872.15 | 9.88 | 0.032 | 0.038 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00814 | -4.30 | 0.00266 | 0.026 | 0.00 |
| G S1 APARTMENT | 850.92 | 1021.11 | 11.57 | 0.037 | 0.044 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00779 | -4.30 | 0.00266 | 0.026 | 0.00 |
| G S2 APARTMENT | 859.46 | 1031.36 | 11.69 | 0.037 | 0.045 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 21.10 | 21.10 | 0.00780 | -4.30 | 0.00266 | 0.026 | 0.00 |
| M SW APARTMENT | 2126.02 | 2551.23 | 28.91 | 0.093 | 0.111 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00763 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M NW APARTMENT | 1833.23 | 2199.87 | 24.93 | 0.080 | 0.096 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00791 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M SE APARTMENT | 2130.88 | 2557.06 | 28.98 | 0.093 | 0.111 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00763 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M NE APARTMENT | 1838.13 | 2205.76 | 24.99 | 0.080 | 0.096 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00791 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M N1 APARTMENT | 816.19 | 979.42 | 11.10 | 0.036 | 0.052 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00811 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M N2 APARTMENT | 816.32 | 979.59 | 11.10 | 0.036 | 0.052 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00811 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M S1 APARTMENT | 1101.43 | 1321.71 | 14.98 | 0.048 | 0.058 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00755 | -4.30 | 0.00266 | 0.052 | 0.00 |
| M S2 APARTMENT | 1101.56 | 1321.87 | 14.98 | 0.048 | 0.058 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00755 | -4.30 | 0.00266 | 0.052 | 0.00 |
| T SW APARTMENT | 2008.70 | 2410.44 | 27.31 | 0.087 | 0.105 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T NW APARTMENT | 1849.76 | 2219.71 | 25.15 | 0.081 | 0.097 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00788 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T SE APARTMENT | 2012.56 | 2415.07 | 27.37 | 0.088 | 0.105 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T NE APARTMENT | 1853.68 | 2224.41 | 25.21 | 0.081 | 0.097 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00789 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T N1 APARTMENT | 1257.74 | 1509.29 | 17.10 | 0.055 | 0.066 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00799 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T N2 APARTMENT | 1257.86 | 1509.43 | 17.10 | 0.055 | 0.066 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00799 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T S1 APARTMENT | 1417.27 | 1700.72 | 19.27 | 0.062 | 0.074 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00778 | -4.30 | 0.00266 | 0.026 | 0.00 |
| T S2 APARTMENT | 1417.38 | 1700.86 | 19.27 | 0.062 | 0.074 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00778 | -4.30 | 0.00266 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.34 | 0.34 | 0.07 | 0.07 | 0.3428 | 0.3428 | 0.3428 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.28 | 0.28 | 0.07 | 0.07 | 0.2812 | 0.2812 | 0.2812 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.37 | 0.37 | 0.10 | 0.10 | 0.3692 | 0.3692 | 0.3692 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.24 | 0.24 | 0.07 | 0.07 | 0.2420 | 0.2420 | 0.2420 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.23 | 0.23 | 0.04 | 0.04 | 0.2279 | 0.2279 | 0.2279 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.23 | 0.23 | 0.04 | 0.04 | 0.2269 | 0.2269 | 0.2269 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.29 | 0.29 | 0.04 | 0.04 | 0.2908 | 0.2908 | 0.2908 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.29 | 0.29 | 0.04 | 0.04 | 0.2921 | 0.2921 | 0.2921 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.86 | 0.86 | 0.11 | 0.11 | 0.8600 | 0.8600 | 0.8600 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.75 | 0.75 | 0.10 | 0.10 | 0.7482 | 0.7482 | 0.7482 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.74 | 0.74 | 0.11 | 0.11 | 0.7391 | 0.7391 | 0.7391 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.63 | 0.63 | 0.10 | 0.10 | 0.6302 | 0.6302 | 0.6302 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.58 | 0.58 | 0.05 | 0.05 | 0.5779 | 0.5779 | 0.5779 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.58 | 0.58 | 0.05 | 0.05 | 0.5759 | 0.5759 | 0.5759 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.70 | 0.70 | 0.06 | 0.06 | 0.7008 | 0.7008 | 0.7008 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.70 | 0.70 | 0.06 | 0.06 | 0.6985 | 0.6985 | 0.6985 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.46 | 0.46 | 0.10 | 0.10 | 0.4590 | 0.4590 | 0.4590 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.41 | 0.41 | 0.10 | 0.10 | 0.4141 | 0.4141 | 0.4141 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.37 | 0.37 | 0.11 | 0.11 | 0.3712 | 0.3712 | 0.3712 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.33 | 0.33 | 0.10 | 0.10 | 0.3268 | 0.3268 | 0.3268 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.32 | 0.32 | 0.07 | 0.07 | 0.3168 | 0.3168 | 0.3168 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.31 | 0.31 | 0.07 | 0.07 | 0.3140 | 0.3140 | 0.3140 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.36 | 0.36 | 0.07 | 0.07 | 0.3646 | 0.3646 | 0.3646 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.36 | 0.36 | 0.07 | 0.07 | 0.3619 | 0.3619 | 0.3619 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 5674.122 | 4543.016 | 0.342774 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5631.74 | 5496.83 | 0.342774 | 24.87 | 16.28 | 0.00814086 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.5719 | 24.00 | 0.00811951 | 43.2705 | 4004.63 | 0.00 | 5673.16 | 4512.85 |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GSW | 8544.994 | 8544.994 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 8544.99 | 8544.99 | 0.342774 | 19.18 | 13.50 | 0.00740578 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.5719 | 21.10 | 0.00779476 | 49.5665 | 1385.32 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 4655.614 | 3727.542 | 0.281246 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4619.99 | 4505.02 | 0.281246 | 24.84 | 16.27 | 0.00814609 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 9.2284 | 24.00 | 0.00812011 | 43.2735 | 3301.64 | 0.00 | 4654.82 | 3702.79 |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNW | 7152.782 | 7152.782 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 7152.78 | 7152.78 | 0.281246 | 18.76 | 13.40 | 0.00747801 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 9.2284 | 21.10 | 0.00796809 | 50.6542 | 1262.78 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 6111.569 | 4893.259 | 0.369200 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 6044.39 | 5991.89 | 0.369200 | 24.61 | 16.11 | 0.00804937 | 12.80 | 11.50 | 0.00800000 | 21.39 | 0.00839928 | 15.25 | 10.3212 | 23.90 | 0.00800484 | 42.9236 | 4085.78 | 0.00 | 6110.53 | 4860.77 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT OFFICE | 9512.424 | 9512.424 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 9512.42 | 9512.42 | 0.369200 | 18.48 | 13.13 | 0.00730818 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 10.3212 | 21.10 | 0.00784342 | 49.8721 | 1827.03 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 4006.544 | 3207.860 | 0.242035 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 3977.23 | 3856.26 | 0.242035 | 24.80 | 16.29 | 0.00817916 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 10.7235 | 24.00 | 0.00815245 | 43.4437 | 2854.49 | 0.00 | 4005.86 | 3186.56 |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GNE | 6265.596 | 6265.596 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 6265.60 | 6265.60 | 0.242035 | 18.38 | 13.18 | 0.00739860 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 10.7235 | 21.10 | 0.00796807 | 50.6541 | 1264.67 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 3771.749 | 3019.871 | 0.227851 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 3745.22 | 3618.04 | 0.227851 | 24.79 | 16.30 | 0.00820056 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 11.3910 | 24.00 | 0.00817472 | 43.5609 | 2693.43 | 0.00 | 3771.11 | 2999.82 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN1 | 5944.649 | 5944.649 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 5944.65 | 5944.65 | 0.227851 | 18.21 | 13.22 | 0.00751534 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 11.3910 | 21.10 | 0.00813982 | 51.7315 | 726.73 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 3756.802 | 3007.904 | 0.226948 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 3730.39 | 3603.30 | 0.226948 | 24.79 | 16.30 | 0.00820123 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 11.4363 | 24.00 | 0.00817536 | 43.5643 | 2683.19 | 0.00 | 3756.16 | 2987.93 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GN2 | 5924.219 | 5924.219 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 5924.22 | 5924.22 | 0.226948 | 18.20 | 13.21 | 0.00751284 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 11.4363 | 21.10 | 0.00813980 | 51.7314 | 726.79 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 4814.537 | 3854.784 | 0.290846 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4781.44 | 4630.08 | 0.290846 | 24.84 | 16.31 | 0.00818724 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 8.9238 | 24.00 | 0.00816625 | 43.5165 | 3411.15 | 0.00 | 4813.72 | 3829.19 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS1 | 7370.036 | 7370.036 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7370.04 | 7370.04 | 0.290846 | 18.83 | 13.30 | 0.00733640 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 8.9238 | 21.10 | 0.00779484 | 49.5667 | 850.92 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 4835.297 | 3871.406 | 0.292100 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4802.03 | 4650.40 | 0.292100 | 24.84 | 16.31 | 0.00818676 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 8.8855 | 24.00 | 0.00816581 | 43.5143 | 3425.36 | 0.00 | 4834.47 | 3845.70 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT GS2 | 7398.413 | 7398.413 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | 7398.41 | 7398.41 | 0.292100 | 18.84 | 13.30 | 0.00734018 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 8.8855 | 21.10 | 0.00779682 | 49.5792 | 859.46 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 14236.349 | 11398.408 | 0.860018 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 14124.21 | 13871.63 | 0.860018 | 24.90 | 16.26 | 0.00810473 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 6.0358 | 24.00 | 0.00808567 | 43.0923 | 19996.77 | 0.00 | 14233.93 | 11322.72 |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSW | 21037.916 | 21037.916 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21037.92 | 21037.92 | 0.860018 | 19.57 | 13.58 | 0.00733306 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 6.0358 | 21.10 | 0.00763339 | 48.5535 | 4252.05 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 12386.095 | 9916.992 | 0.748244 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12287.09 | 12065.02 | 0.748244 | 24.89 | 16.25 | 0.00810573 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 6.9375 | 24.00 | 0.00808368 | 43.0818 | 17444.41 | 0.00 | 12383.99 | 9851.14 |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNW | 18508.545 | 18508.545 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18508.54 | 18508.54 | 0.748244 | 19.34 | 13.69 | 0.00754173 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 6.9375 | 21.10 | 0.00790582 | 50.2636 | 3666.45 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 12234.151 | 9795.337 | 0.739065 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12141.38 | 11872.66 | 0.739065 | 24.88 | 16.27 | 0.00813000 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.0236 | 24.00 | 0.00810949 | 43.2177 | 17235.06 | 0.00 | 12232.07 | 9730.29 |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MSE | 18301.135 | 18301.135 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 18301.13 | 18301.13 | 0.739065 | 19.32 | 13.44 | 0.00728466 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.0236 | 21.10 | 0.00763419 | 48.5585 | 4261.76 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 10432.410 | 8352.764 | 0.630222 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 10351.82 | 10118.88 | 0.630222 | 24.86 | 16.27 | 0.00813200 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 8.2366 | 24.00 | 0.00810780 | 43.2087 | 14754.67 | 0.00 | 10430.63 | 8297.30 |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MNE | 15838.123 | 15838.123 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 15838.12 | 15838.12 | 0.630222 | 19.01 | 13.50 | 0.00747378 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 8.2366 | 21.10 | 0.00790608 | 50.2652 | 3676.27 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 9566.991 | 7659.862 | 0.577942 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 9494.75 | 9253.14 | 0.577942 | 24.84 | 16.28 | 0.00814953 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 8.9817 | 24.00 | 0.00812466 | 43.2975 | 13557.79 | 0.00 | 9565.36 | 7609.00 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN1 | 14655.119 | 14655.119 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 14655.12 | 14655.12 | 0.577942 | 18.82 | 13.56 | 0.00762311 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 8.9817 | 21.10 | 0.00798334 | 50.7499 | 1353.55 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 9532.925 | 7632.586 | 0.575884 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 9460.99 | 9219.32 | 0.575884 | 24.84 | 16.28 | 0.00815011 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 9.0138 | 24.00 | 0.00812520 | 43.3003 | 13510.94 | 0.00 | 9531.30 | 7581.91 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MN2 | 14608.555 | 14608.555 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:00:00 | 14608.56 | 14608.56 | 0.575884 | 18.81 | 13.56 | 0.00762136 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 9.0138 | 21.10 | 0.00766163 | 48.7299 | 976.36 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 11601.192 | 9288.556 | 0.700828 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11514.78 | 11239.44 | 0.700828 | 24.88 | 16.28 | 0.00814064 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.4068 | 24.00 | 0.00811977 | 43.2718 | 16365.44 | 0.00 | 11599.22 | 9226.88 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS1 | 17435.843 | 17435.843 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17435.84 | 17435.84 | 0.700828 | 19.22 | 13.31 | 0.00718785 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.4068 | 21.10 | 0.00755024 | 48.0305 | 2202.85 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 11563.233 | 9258.163 | 0.698535 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11477.21 | 11201.44 | 0.698535 | 24.88 | 16.28 | 0.00814133 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.4311 | 24.00 | 0.00812044 | 43.2754 | 16313.35 | 0.00 | 11561.27 | 9196.69 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT MS2 | 17383.957 | 17383.957 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 17383.96 | 17383.96 | 0.698535 | 19.21 | 13.30 | 0.00718671 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.4311 | 21.10 | 0.00755030 | 48.0309 | 2203.12 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 7598.448 | 6083.738 | 0.459022 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 7538.21 | 7413.12 | 0.459022 | 24.92 | 16.26 | 0.00809713 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 5.6543 | 24.00 | 0.00807889 | 43.0566 | 5333.98 | 0.00 | 7597.16 | 6043.34 |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSW | 11175.512 | 11175.512 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11175.51 | 11175.51 | 0.459022 | 19.66 | 13.73 | 0.00745316 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 5.6543 | 21.10 | 0.00774057 | 49.2273 | 2008.70 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 6854.379 | 5487.995 | 0.414073 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6799.21 | 6688.60 | 0.414073 | 24.90 | 16.25 | 0.00809511 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 6.2681 | 24.00 | 0.00807462 | 43.0341 | 4820.22 | 0.00 | 6853.21 | 5451.55 |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNW | 10158.287 | 10158.287 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 10158.29 | 10158.29 | 0.414073 | 19.51 | 13.77 | 0.00755727 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 6.2681 | 21.10 | 0.00788493 | 50.1328 | 1849.76 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 6145.259 | 4920.234 | 0.371235 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6098.38 | 5968.54 | 0.371235 | 24.89 | 16.27 | 0.00812499 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 6.9914 | 24.00 | 0.00810421 | 43.1899 | 4330.59 | 0.00 | 6144.21 | 4887.56 |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TSE | 9189.149 | 9189.149 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9189.15 | 9189.15 | 0.371235 | 19.32 | 13.54 | 0.00738564 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 6.9914 | 21.10 | 0.00774105 | 49.2303 | 2012.56 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 5410.066 | 4331.597 | 0.326822 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5367.89 | 5255.42 | 0.326822 | 24.87 | 16.26 | 0.00812281 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.9415 | 24.00 | 0.00809877 | 43.1612 | 3824.29 | 0.00 | 5409.14 | 4302.84 |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TNE | 8184.093 | 8184.093 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 8184.09 | 8184.09 | 0.326822 | 19.08 | 13.52 | 0.00747001 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.9415 | 21.10 | 0.00788516 | 50.1343 | 1853.68 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 5243.495 | 4198.232 | 0.316760 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5202.58 | 5092.24 | 0.316760 | 24.87 | 16.26 | 0.00812431 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 8.1938 | 24.00 | 0.00809956 | 43.1653 | 3709.92 | 0.00 | 5242.60 | 4170.36 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN1 | 7956.332 | 7956.332 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7956.33 | 7956.33 | 0.316760 | 19.02 | 13.58 | 0.00755694 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 8.1938 | 21.10 | 0.00799421 | 50.8181 | 1257.74 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 5197.779 | 4161.629 | 0.313998 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5157.29 | 5046.86 | 0.313998 | 24.87 | 16.26 | 0.00812552 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 8.2658 | 24.00 | 0.00810065 | 43.1710 | 3678.57 | 0.00 | 5196.89 | 4134.00 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TN2 | 7893.845 | 7893.845 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7893.84 | 7893.84 | 0.313998 | 19.00 | 13.57 | 0.00755310 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 8.2658 | 21.10 | 0.00799421 | 50.8181 | 1257.86 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 6035.942 | 4832.709 | 0.364631 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5989.85 | 5861.69 | 0.364631 | 24.89 | 16.27 | 0.00812560 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.1180 | 24.00 | 0.00810446 | 43.1912 | 4255.08 | 0.00 | 6034.92 | 4800.62 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS1 | 9039.639 | 9039.639 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 9039.64 | 9039.64 | 0.364631 | 19.29 | 13.55 | 0.00741147 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.1180 | 21.10 | 0.00777578 | 49.4478 | 1417.27 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 5990.166 | 4796.058 | 0.361866 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5944.50 | 5816.11 | 0.361866 | 24.89 | 16.27 | 0.00812681 | 12.80 | 11.50 | 0.00800000 | 22.85 | 0.00840154 | 15.78 | 7.1724 | 24.00 | 0.00810559 | 43.1971 | 4223.54 | 0.00 | 5989.15 | 4764.21 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoopHVAC | SPLIT TS2 | 8977.068 | 8977.068 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 8977.07 | 8977.07 | 0.361866 | 19.28 | 13.54 | 0.00740870 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 7.1724 | 21.10 | 0.00777580 | 49.4479 | 1417.38 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5674.122 | 4543.016 | 0.342774 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9735 | 1004.8586 | 1.1914 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.342774 | 0.40837101 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5631.74 | 5496.83 | 0.9925 | 0.40837101 | 0.342774 | 24.87 | 16.28 | 0.00814086 | 45730.3 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 383.944 | 5247.80 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 7.5719 | 24.04 | 0.00811951 | 24.00 | 0.00811951 | 43.2705 | 4004.63 | 0.00 | 5673.16 | 4512.85 | 0.39224344 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8544.994 | 8544.994 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.342774 | 0.40837101 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 8544.99 | 8544.99 | 1.0000 | 0.40837101 | 0.342774 | 19.18 | 13.50 | 0.00740578 | 38054.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8544.99 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 7.5719 | 21.10 | 0.00779476 | 21.10 | 0.00779476 | 49.5665 | 1385.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4655.614 | 3727.542 | 0.281246 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9832 | 1004.8586 | 1.1914 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.281246 | 0.33506820 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4619.99 | 4505.02 | 0.9923 | 0.33506820 | 0.281246 | 24.84 | 16.27 | 0.00814609 | 45704.9 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 315.025 | 4304.97 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 9.2284 | 24.02 | 0.00812011 | 24.00 | 0.00812011 | 43.2735 | 3301.64 | 0.00 | 4654.82 | 3702.79 | 0.32183553 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7152.782 | 7152.782 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.281246 | 0.33506820 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 7152.78 | 7152.78 | 1.0000 | 0.33506820 | 0.281246 | 18.76 | 13.40 | 0.00747801 | 37809.5 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7152.78 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 9.2284 | 21.10 | 0.00796809 | 21.10 | 0.00796809 | 50.6542 | 1262.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6111.569 | 4893.259 | 0.369200 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8034 | 1004.8586 | 1.1914 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.369200 | 0.43985437 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | Sensible | 6044.39 | 5991.89 | 0.9890 | 0.43985437 | 0.369200 | 24.61 | 16.11 | 0.00804937 | 45226.8 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 413.544 | 5630.85 | 21.39 | 0.00839928 | 15.25 | 0.03810604 | 10.3212 | 23.95 | 0.00800909 | 23.90 | 0.00800484 | 42.9236 | 4085.78 | 0.00 | 6110.53 | 4860.77 | 0.42248345 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9512.424 | 9512.424 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.369200 | 0.43985437 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 9512.42 | 9512.42 | 1.0000 | 0.43985437 | 0.369200 | 18.48 | 13.13 | 0.00730818 | 37096.1 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9512.42 | -4.30 | 0.00265759 | -4.30 | 0.03810604 | 10.3212 | 21.10 | 0.00784342 | 21.10 | 0.00784342 | 49.8721 | 1827.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4006.544 | 3207.860 | 0.242035 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0446 | 1004.8586 | 1.1914 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.242035 | 0.28835408 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 3977.23 | 3856.26 | 0.9927 | 0.28835408 | 0.242035 | 24.80 | 16.29 | 0.00817916 | 45754.8 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 271.106 | 3706.13 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 10.7235 | 24.00 | 0.00815245 | 24.00 | 0.00815245 | 43.4437 | 2854.49 | 0.00 | 4005.86 | 3186.56 | 0.27696627 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6265.596 | 6265.596 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.242035 | 0.28835408 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 6265.60 | 6265.60 | 1.0000 | 0.28835408 | 0.242035 | 18.38 | 13.18 | 0.00739860 | 37221.4 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6265.60 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 10.7235 | 21.10 | 0.00796807 | 21.10 | 0.00796807 | 50.6541 | 1264.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 3771.749 | 3019.871 | 0.227851 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0844 | 1004.8586 | 1.1914 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.227851 | 0.27145575 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 3745.22 | 3618.04 | 0.9930 | 0.27145575 | 0.227851 | 24.79 | 16.30 | 0.00820056 | 45796.1 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 255.218 | 3490.00 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 11.3910 | 24.00 | 0.00817472 | 24.00 | 0.00817472 | 43.5609 | 2693.43 | 0.00 | 3771.11 | 2999.82 | 0.26073530 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5944.649 | 5944.649 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.227851 | 0.27145575 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 5944.65 | 5944.65 | 1.0000 | 0.27145575 | 0.227851 | 18.21 | 13.22 | 0.00751534 | 37344.6 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5944.65 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 11.3910 | 21.10 | 0.00813982 | 21.10 | 0.00813982 | 51.7315 | 726.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 3756.802 | 3007.904 | 0.226948 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0857 | 1004.8586 | 1.1914 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.226948 | 0.27038002 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 3730.39 | 3603.30 | 0.9930 | 0.27038002 | 0.226948 | 24.79 | 16.30 | 0.00820123 | 45796.6 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 254.207 | 3476.18 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 11.4363 | 24.00 | 0.00817536 | 24.00 | 0.00817536 | 43.5643 | 2683.19 | 0.00 | 3756.16 | 2987.93 | 0.25970205 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5924.219 | 5924.219 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.226948 | 0.27038002 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 5924.22 | 5924.22 | 1.0000 | 0.27038002 | 0.226948 | 18.20 | 13.21 | 0.00751284 | 37326.6 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5924.22 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 11.4363 | 21.10 | 0.00813980 | 21.10 | 0.00813980 | 51.7314 | 726.79 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4814.537 | 3854.784 | 0.290846 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0597 | 1004.8586 | 1.1914 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.290846 | 0.34650599 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4781.44 | 4630.08 | 0.9931 | 0.34650599 | 0.290846 | 24.84 | 16.31 | 0.00818724 | 45817.9 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 325.779 | 4455.66 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 8.9238 | 24.03 | 0.00816625 | 24.00 | 0.00816625 | 43.5165 | 3411.15 | 0.00 | 4813.72 | 3829.19 | 0.33282163 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7370.036 | 7370.036 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.290846 | 0.34650599 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7370.04 | 7370.04 | 1.0000 | 0.34650599 | 0.290846 | 18.83 | 13.30 | 0.00733640 | 37529.2 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7370.04 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 8.9238 | 21.10 | 0.00779484 | 21.10 | 0.00779484 | 49.5667 | 850.92 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4835.297 | 3871.406 | 0.292100 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0588 | 1004.8586 | 1.1914 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.292100 | 0.34800013 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4802.03 | 4650.40 | 0.9931 | 0.34800013 | 0.292100 | 24.84 | 16.31 | 0.00818676 | 45817.1 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 327.184 | 4474.85 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 8.8855 | 24.03 | 0.00816581 | 24.00 | 0.00816581 | 43.5143 | 3425.36 | 0.00 | 4834.47 | 3845.70 | 0.33425675 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7398.413 | 7398.413 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.292100 | 0.34800013 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:50:00 | Sensible | 7398.41 | 7398.41 | 1.0000 | 0.34800013 | 0.292100 | 18.84 | 13.30 | 0.00734018 | 37548.7 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7398.41 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 8.8855 | 21.10 | 0.00779682 | 21.10 | 0.00779682 | 49.5792 | 859.46 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14236.349 | 11398.408 | 0.860018 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9063 | 1004.8586 | 1.1914 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.860018 | 1.02460121 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 14124.21 | 13871.63 | 0.9921 | 1.02460121 | 0.860018 | 24.90 | 16.26 | 0.00810473 | 45670.1 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 963.313 | 13160.90 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 6.0358 | 24.06 | 0.00808567 | 24.00 | 0.00808567 | 43.0923 | 19996.77 | 0.00 | 14233.93 | 11322.72 | 0.98413721 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21037.916 | 21037.916 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.860018 | 1.02460121 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 21037.92 | 21037.92 | 1.0000 | 1.02460121 | 0.860018 | 19.57 | 13.58 | 0.00733306 | 38267.5 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21037.92 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 6.0358 | 21.10 | 0.00763339 | 21.10 | 0.00763339 | 48.5535 | 4252.05 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12386.095 | 9916.992 | 0.748244 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9082 | 1004.8586 | 1.1914 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.748244 | 0.89143696 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12287.09 | 12065.02 | 0.9920 | 0.89143696 | 0.748244 | 24.89 | 16.25 | 0.00810573 | 45653.7 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 838.114 | 11448.98 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 6.9375 | 24.05 | 0.00808368 | 24.00 | 0.00808368 | 43.0818 | 17444.41 | 0.00 | 12383.99 | 9851.14 | 0.85623194 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18508.545 | 18508.545 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.748244 | 0.89143696 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18508.54 | 18508.54 | 1.0000 | 0.89143696 | 0.748244 | 19.34 | 13.69 | 0.00754173 | 38563.9 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18508.54 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 6.9375 | 21.10 | 0.00790582 | 21.10 | 0.00790582 | 50.2636 | 3666.45 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12234.151 | 9795.337 | 0.739065 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9533 | 1004.8586 | 1.1914 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.739065 | 0.88050141 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12141.38 | 11872.66 | 0.9924 | 0.88050141 | 0.739065 | 24.88 | 16.27 | 0.00813000 | 45713.5 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 827.833 | 11313.55 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 7.0236 | 24.05 | 0.00810949 | 24.00 | 0.00810949 | 43.2177 | 17235.06 | 0.00 | 12232.07 | 9730.29 | 0.84572826 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 18301.135 | 18301.135 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.739065 | 0.88050141 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 18301.13 | 18301.13 | 1.0000 | 0.88050141 | 0.739065 | 19.32 | 13.44 | 0.00728466 | 37889.1 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18301.13 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 7.0236 | 21.10 | 0.00763419 | 21.10 | 0.00763419 | 48.5585 | 4261.76 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10432.410 | 8352.764 | 0.630222 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9570 | 1004.8586 | 1.1914 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.630222 | 0.75082869 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 10351.82 | 10118.88 | 0.9923 | 0.75082869 | 0.630222 | 24.86 | 16.27 | 0.00813200 | 45693.5 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 705.917 | 9645.91 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 8.2366 | 24.04 | 0.00810780 | 24.00 | 0.00810780 | 43.2087 | 14754.67 | 0.00 | 10430.63 | 8297.30 | 0.72117663 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 15838.123 | 15838.123 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.630222 | 0.75082869 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 15838.12 | 15838.12 | 1.0000 | 0.75082869 | 0.630222 | 19.01 | 13.50 | 0.00747378 | 38055.4 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15838.12 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 8.2366 | 21.10 | 0.00790608 | 21.10 | 0.00790608 | 50.2652 | 3676.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9566.991 | 7659.862 | 0.577942 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9896 | 1004.8586 | 1.1914 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.577942 | 0.68854385 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 9494.75 | 9253.14 | 0.9924 | 0.68854385 | 0.577942 | 24.84 | 16.28 | 0.00814953 | 45719.4 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 647.357 | 8847.40 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 8.9817 | 24.03 | 0.00812466 | 24.00 | 0.00812466 | 43.2975 | 13557.79 | 0.00 | 9565.36 | 7609.00 | 0.66135157 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14655.119 | 14655.119 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.577942 | 0.68854385 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 14655.12 | 14655.12 | 1.0000 | 0.68854385 | 0.577942 | 18.82 | 13.56 | 0.00762311 | 38241.4 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14655.12 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 8.9817 | 21.10 | 0.00811310 | 21.10 | 0.00798334 | 50.7499 | 1353.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 9532.925 | 7632.586 | 0.575884 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9906 | 1004.8586 | 1.1914 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.575884 | 0.68609207 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 9460.99 | 9219.32 | 0.9925 | 0.68609207 | 0.575884 | 24.84 | 16.28 | 0.00815011 | 45720.2 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 645.052 | 8815.94 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 9.0138 | 24.02 | 0.00812520 | 24.00 | 0.00812520 | 43.3003 | 13510.94 | 0.00 | 9531.30 | 7581.91 | 0.65899662 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14608.555 | 14608.555 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.575884 | 0.68609207 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 18:00:00 | Sensible | 14608.56 | 14608.56 | 1.0000 | 0.68609207 | 0.575884 | 18.81 | 13.56 | 0.00762136 | 38228.6 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14608.56 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 9.0138 | 21.10 | 0.00811311 | 21.10 | 0.00766163 | 48.7299 | 976.36 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11601.192 | 9288.556 | 0.700828 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9730 | 1004.8586 | 1.1914 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.700828 | 0.83494689 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11514.78 | 11239.44 | 0.9926 | 0.83494689 | 0.700828 | 24.88 | 16.28 | 0.00814064 | 45733.3 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 785.003 | 10729.78 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 7.4068 | 24.04 | 0.00811977 | 24.00 | 0.00811977 | 43.2718 | 16365.44 | 0.00 | 11599.22 | 9226.88 | 0.80197280 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17435.843 | 17435.843 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.700828 | 0.83494689 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17435.84 | 17435.84 | 1.0000 | 0.83494689 | 0.700828 | 19.22 | 13.31 | 0.00718785 | 37544.6 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17435.84 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 7.4068 | 21.10 | 0.00755024 | 21.10 | 0.00755024 | 48.0305 | 2202.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11563.233 | 9258.163 | 0.698535 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9743 | 1004.8586 | 1.1914 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.698535 | 0.83221494 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11477.21 | 11201.44 | 0.9926 | 0.83221494 | 0.698535 | 24.88 | 16.28 | 0.00814133 | 45734.6 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 782.435 | 10694.78 | 22.85 | 0.00840154 | 15.78 | 0.05190911 | 7.4311 | 24.04 | 0.00812044 | 24.00 | 0.00812044 | 43.2754 | 16313.35 | 0.00 | 11561.27 | 9196.69 | 0.79934874 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17383.957 | 17383.957 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.698535 | 0.83221494 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 17383.96 | 17383.96 | 1.0000 | 0.83221494 | 0.698535 | 19.21 | 13.30 | 0.00718671 | 37535.4 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17383.96 | -4.30 | 0.00265759 | -4.30 | 0.05190911 | 7.4311 | 21.10 | 0.00755030 | 21.10 | 0.00755030 | 48.0309 | 2203.12 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7598.448 | 6083.738 | 0.459022 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8922 | 1004.8586 | 1.1914 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.459022 | 0.54686628 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 7538.21 | 7413.12 | 0.9921 | 0.54686628 | 0.459022 | 24.92 | 16.26 | 0.00809713 | 45662.4 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 514.154 | 7024.06 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 5.6543 | 24.06 | 0.00807889 | 24.00 | 0.00807889 | 43.0566 | 5333.98 | 0.00 | 7597.16 | 6043.34 | 0.52526920 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11175.512 | 11175.512 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.459022 | 0.54686628 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11175.51 | 11175.51 | 1.0000 | 0.54686628 | 0.459022 | 19.66 | 13.73 | 0.00745316 | 38670.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11175.51 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 5.6543 | 21.10 | 0.00774057 | 21.10 | 0.00774057 | 49.2273 | 2008.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6854.379 | 5487.995 | 0.414073 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8884 | 1004.8586 | 1.1914 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.414073 | 0.49331504 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6799.21 | 6688.60 | 0.9920 | 0.49331504 | 0.414073 | 24.90 | 16.25 | 0.00809511 | 45645.1 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 463.807 | 6335.41 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 6.2681 | 24.06 | 0.00807462 | 24.00 | 0.00807462 | 43.0341 | 4820.22 | 0.00 | 6853.21 | 5451.55 | 0.47383283 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10158.287 | 10158.287 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.414073 | 0.49331504 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 10158.29 | 10158.29 | 1.0000 | 0.49331504 | 0.414073 | 19.51 | 13.77 | 0.00755727 | 38776.4 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10158.29 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 6.2681 | 21.10 | 0.00788493 | 21.10 | 0.00788493 | 50.1328 | 1849.76 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6145.259 | 4920.234 | 0.371235 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9440 | 1004.8586 | 1.1914 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.371235 | 0.44227908 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6098.38 | 5968.54 | 0.9924 | 0.44227908 | 0.371235 | 24.89 | 16.27 | 0.00812499 | 45706.6 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 415.823 | 5682.56 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 6.9914 | 24.05 | 0.00810421 | 24.00 | 0.00810421 | 43.1899 | 4330.59 | 0.00 | 6144.21 | 4887.56 | 0.42481240 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9189.149 | 9189.149 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.371235 | 0.44227908 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9189.15 | 9189.15 | 1.0000 | 0.44227908 | 0.371235 | 19.32 | 13.54 | 0.00738564 | 38153.5 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9189.15 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 6.9914 | 21.10 | 0.00774105 | 21.10 | 0.00774105 | 49.2303 | 2012.56 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5410.066 | 4331.597 | 0.326822 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9399 | 1004.8586 | 1.1914 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.326822 | 0.38936666 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5367.89 | 5255.42 | 0.9922 | 0.38936666 | 0.326822 | 24.87 | 16.26 | 0.00812281 | 45682.8 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 366.076 | 5001.81 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 7.9415 | 24.05 | 0.00809877 | 24.00 | 0.00809877 | 43.1612 | 3824.29 | 0.00 | 5409.14 | 4302.84 | 0.37398962 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8184.093 | 8184.093 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.326822 | 0.38936666 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 8184.09 | 8184.09 | 1.0000 | 0.38936666 | 0.326822 | 19.08 | 13.52 | 0.00747001 | 38122.0 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8184.09 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 7.9415 | 21.10 | 0.00788516 | 21.10 | 0.00788516 | 50.1343 | 1853.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5243.495 | 4198.232 | 0.316760 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9427 | 1004.8586 | 1.1914 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.316760 | 0.37737845 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5202.58 | 5092.24 | 0.9922 | 0.37737845 | 0.316760 | 24.87 | 16.26 | 0.00812431 | 45681.9 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 354.805 | 4847.78 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 8.1938 | 24.04 | 0.00809956 | 24.00 | 0.00809956 | 43.1653 | 3709.92 | 0.00 | 5242.60 | 4170.36 | 0.36247486 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7956.332 | 7956.332 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.316760 | 0.37737845 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7956.33 | 7956.33 | 1.0000 | 0.37737845 | 0.316760 | 19.02 | 13.58 | 0.00755694 | 38277.5 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7956.33 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 8.1938 | 21.10 | 0.00799421 | 21.10 | 0.00799421 | 50.8181 | 1257.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5197.779 | 4161.629 | 0.313998 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9449 | 1004.8586 | 1.1914 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.313998 | 0.37408821 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5157.29 | 5046.86 | 0.9922 | 0.37408821 | 0.313998 | 24.87 | 16.26 | 0.00812552 | 45683.8 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 351.711 | 4805.58 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 8.2658 | 24.04 | 0.00810065 | 24.00 | 0.00810065 | 43.1710 | 3678.57 | 0.00 | 5196.89 | 4134.00 | 0.35931456 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7893.845 | 7893.845 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.313998 | 0.37408821 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7893.84 | 7893.84 | 1.0000 | 0.37408821 | 0.313998 | 19.00 | 13.57 | 0.00755310 | 38249.1 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7893.84 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 8.2658 | 21.10 | 0.00799421 | 21.10 | 0.00799421 | 50.8181 | 1257.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6035.942 | 4832.709 | 0.364631 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9451 | 1004.8586 | 1.1914 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.364631 | 0.43441151 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5989.85 | 5861.69 | 0.9924 | 0.43441151 | 0.364631 | 24.89 | 16.27 | 0.00812560 | 45705.5 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 408.426 | 5581.42 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 7.1180 | 24.05 | 0.00810446 | 24.00 | 0.00810446 | 43.1912 | 4255.08 | 0.00 | 6034.92 | 4800.62 | 0.41725554 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9039.639 | 9039.639 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.364631 | 0.43441151 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 9039.64 | 9039.64 | 1.0000 | 0.43441151 | 0.364631 | 19.29 | 13.55 | 0.00741147 | 38186.5 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9039.64 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 7.1180 | 21.10 | 0.00777578 | 21.10 | 0.00777578 | 49.4478 | 1417.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5990.166 | 4796.058 | 0.361866 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9473 | 1004.8586 | 1.1914 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.361866 | 0.43111695 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5944.50 | 5816.11 | 0.9924 | 0.43111695 | 0.361866 | 24.89 | 16.27 | 0.00812681 | 45707.5 | 12.80 | 11.50 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 405.329 | 5539.17 | 22.85 | 0.00840154 | 15.78 | 0.02595455 | 7.1724 | 24.05 | 0.00810559 | 24.00 | 0.00810559 | 43.1971 | 4223.54 | 0.00 | 5989.15 | 4764.21 | 0.41409109 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.43 | 14.60 | 0.01002485 | 40859.0 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:FUEL | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 8977.068 | 8977.068 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.361866 | 0.43111695 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 8977.07 | 8977.07 | 1.0000 | 0.43111695 | 0.361866 | 19.28 | 13.54 | 0.00740870 | 38165.4 | 40.00 | 21.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8977.07 | -4.30 | 0.00265759 | -4.30 | 0.02595455 | 7.1724 | 21.10 | 0.00777580 | 21.10 | 0.00777580 | 49.4479 | 1417.38 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 1814.00 | 5141.83 | 1618.00 |
| G NW APARTMENT | 3220.00 | 8090.67 | 3165.00 |
| OFFICE | 909.67 | 1144.17 | 542.50 |
| G NE APARTMENT | 3185.50 | 8002.00 | 3140.17 |
| G N1 APARTMENT | 2194.33 | 8014.33 | 2171.67 |
| G N2 APARTMENT | 2192.33 | 8002.67 | 2170.00 |
| G S1 APARTMENT | 787.33 | 4840.00 | 622.17 |
| G S2 APARTMENT | 1081.50 | 4772.00 | 885.33 |
| M SW APARTMENT | 745.67 | 4294.17 | 327.17 |
| M NW APARTMENT | 1370.17 | 6632.00 | 1006.67 |
| M SE APARTMENT | 685.50 | 4308.50 | 319.50 |
| M NE APARTMENT | 1255.00 | 6498.33 | 952.67 |
| M N1 APARTMENT | 377.17 | 6350.17 | 266.00 |
| M N2 APARTMENT | 375.17 | 6330.67 | 264.83 |
| M S1 APARTMENT | 331.00 | 4005.17 | 50.50 |
| M S2 APARTMENT | 330.17 | 4004.00 | 50.67 |
| T SW APARTMENT | 2402.67 | 5185.83 | 1967.50 |
| T NW APARTMENT | 3689.33 | 7589.17 | 3152.83 |
| T SE APARTMENT | 2355.83 | 5210.83 | 1967.33 |
| T NE APARTMENT | 3706.17 | 7427.00 | 3145.67 |
| T N1 APARTMENT | 2831.00 | 7620.83 | 2514.50 |
| T N2 APARTMENT | 2836.50 | 7603.50 | 2516.17 |
| T S1 APARTMENT | 1678.00 | 5127.33 | 1339.67 |
| T S2 APARTMENT | 1679.83 | 5128.00 | 1341.67 |
| T CORRIDOR | 8356.17 | 8756.33 | 8353.67 |
| G CORRIDOR | 5004.50 | 7484.00 | 4325.67 |
| M CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| Facility | 8760.00 | 8760.00 | 8760.00 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.054 | 0.000 | 0.026 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.057 | 0.000 | 0.044 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.517 | 0.061 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.057 | 0.000 | 0.044 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.034 | 0.000 | 0.044 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.034 | 0.000 | 0.044 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.033 | 0.000 | 0.026 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.033 | 0.000 | 0.026 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.078 | 0.000 | 0.029 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.082 | 0.000 | 0.050 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.078 | 0.000 | 0.029 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.082 | 0.000 | 0.050 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.049 | 0.000 | 0.050 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.049 | 0.000 | 0.050 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.047 | 0.000 | 0.029 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.047 | 0.000 | 0.029 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.103 | 0.000 | 0.032 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.108 | 0.000 | 0.055 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.103 | 0.000 | 0.032 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.108 | 0.000 | 0.056 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.065 | 0.000 | 0.056 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.065 | 0.000 | 0.056 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.062 | 0.000 | 0.032 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.062 | 0.000 | 0.032 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.498 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.19 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 102825.66 | 921328.43 | 132563.99 | 1053892.43 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| G NW APARTMENT | 818502.78 | 100678.38 | 919181.15 | 132563.99 | 1051745.14 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| OFFICE | 1201711.97 | 0.00 | 1201711.97 | 132563.99 | 1334275.96 | 1201711.97 | 0.00 | 8760.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 101754.45 | 920257.23 | 132563.99 | 1052821.22 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| G N1 APARTMENT | 818502.78 | 100959.46 | 919462.24 | 79959.23 | 999421.47 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| G N2 APARTMENT | 818502.78 | 101053.16 | 919555.94 | 79959.23 | 999515.17 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| G S1 APARTMENT | 818502.78 | 103171.70 | 921674.48 | 79959.23 | 1001633.72 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 103279.62 | 921782.40 | 79959.23 | 1001741.63 | 818502.78 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 114277.12 | 1751282.67 | 190504.81 | 1941787.48 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 115600.75 | 1752606.30 | 190504.81 | 1943111.11 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| M SE APARTMENT | 1637005.55 | 114293.42 | 1751298.97 | 190504.81 | 1941803.78 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 115899.88 | 1752905.43 | 190504.81 | 1943410.24 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 115762.27 | 1752767.82 | 114907.66 | 1867675.49 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 115789.69 | 1752795.25 | 114907.66 | 1867702.91 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 114310.26 | 1751315.81 | 114907.66 | 1866223.47 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 114310.52 | 1751316.07 | 114907.66 | 1866223.73 | 1637005.55 | 0.00 | 7693.00 | 1067.00 | 2615.00 |
| T SW APARTMENT | 818502.78 | 126337.59 | 944840.37 | 251999.09 | 1196839.45 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 2615.00 |
| T NW APARTMENT | 818502.78 | 127829.83 | 946332.61 | 251999.09 | 1198331.69 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 0.00 |
| T SE APARTMENT | 818502.78 | 127028.03 | 945530.81 | 251999.09 | 1197529.89 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 2615.00 |
| T NE APARTMENT | 818502.78 | 129293.47 | 947796.25 | 251999.09 | 1199795.33 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 0.00 |
| T N1 APARTMENT | 818502.78 | 128224.07 | 946726.85 | 151999.45 | 1098726.30 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 0.00 |
| T N2 APARTMENT | 818502.78 | 128357.96 | 946860.73 | 151999.45 | 1098860.19 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 0.00 |
| T S1 APARTMENT | 818502.78 | 126774.96 | 945277.73 | 151999.45 | 1097277.18 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 126808.83 | 945311.61 | 151999.45 | 1097311.06 | 818502.78 | 0.00 | 7693.50 | 1066.50 | 2615.00 |
| Total Facility | 39671342.50 | 3574864.95 | 43246207.46 | 4909386.80 | 48155594.26 | 39671342.50 | 0.00 | 8760.00 | 1067.33 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0019 | 0.0279 | 0.0040 | 0.0319 | 0.0260 | 0.00 | 5712.00 | 433.00 |
| G NW APARTMENT | 0.0260 | 0.0032 | 0.0291 | 0.0042 | 0.0334 | 0.0260 | 0.00 | 7693.00 | 1067.00 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0045 | 0.0426 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0032 | 0.0292 | 0.0042 | 0.0334 | 0.0260 | 0.00 | 7693.00 | 1067.00 |
| G N1 APARTMENT | 0.0260 | 0.0032 | 0.0292 | 0.0025 | 0.0317 | 0.0260 | 0.00 | 7693.00 | 1067.00 |
| G N2 APARTMENT | 0.0260 | 0.0032 | 0.0292 | 0.0025 | 0.0317 | 0.0260 | 0.00 | 7693.00 | 1067.00 |
| G S1 APARTMENT | 0.0260 | 0.0019 | 0.0279 | 0.0024 | 0.0303 | 0.0260 | 0.00 | 5712.00 | 433.00 |
| G S2 APARTMENT | 0.0260 | 0.0019 | 0.0279 | 0.0024 | 0.0303 | 0.0260 | 0.00 | 5712.00 | 433.00 |
| M SW APARTMENT | 0.0519 | 0.0021 | 0.0540 | 0.0058 | 0.0598 | 0.0519 | 0.00 | 5712.00 | 433.00 |
| M NW APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0060 | 0.0616 | 0.0519 | 0.00 | 7693.00 | 1067.00 |
| M SE APARTMENT | 0.0519 | 0.0021 | 0.0540 | 0.0058 | 0.0598 | 0.0519 | 0.00 | 5712.00 | 433.00 |
| M NE APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0060 | 0.0616 | 0.0519 | 0.00 | 7693.00 | 1067.00 |
| M N1 APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0036 | 0.0592 | 0.0519 | 0.00 | 7693.00 | 1067.00 |
| M N2 APARTMENT | 0.0519 | 0.0037 | 0.0556 | 0.0036 | 0.0592 | 0.0519 | 0.00 | 7693.00 | 1067.00 |
| M S1 APARTMENT | 0.0519 | 0.0021 | 0.0540 | 0.0035 | 0.0575 | 0.0519 | 0.00 | 5712.00 | 433.00 |
| M S2 APARTMENT | 0.0519 | 0.0021 | 0.0540 | 0.0035 | 0.0575 | 0.0519 | 0.00 | 5712.00 | 433.00 |
| T SW APARTMENT | 0.0260 | 0.0023 | 0.0283 | 0.0076 | 0.0359 | 0.0260 | 0.00 | 5712.17 | 432.83 |
| T NW APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0080 | 0.0380 | 0.0260 | 0.00 | 7693.50 | 1066.50 |
| T SE APARTMENT | 0.0260 | 0.0024 | 0.0283 | 0.0076 | 0.0359 | 0.0260 | 0.00 | 5712.17 | 432.83 |
| T NE APARTMENT | 0.0260 | 0.0041 | 0.0301 | 0.0080 | 0.0380 | 0.0260 | 0.00 | 7693.50 | 1066.50 |
| T N1 APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0048 | 0.0348 | 0.0260 | 0.00 | 7693.50 | 1066.50 |
| T N2 APARTMENT | 0.0260 | 0.0041 | 0.0300 | 0.0048 | 0.0348 | 0.0260 | 0.00 | 7693.50 | 1066.50 |
| T S1 APARTMENT | 0.0260 | 0.0023 | 0.0283 | 0.0046 | 0.0329 | 0.0260 | 0.00 | 5712.17 | 432.83 |
| T S2 APARTMENT | 0.0260 | 0.0023 | 0.0283 | 0.0046 | 0.0329 | 0.0260 | 0.00 | 5712.17 | 432.83 |
| Total Facility | 1.2580 | 0.0907 | 1.3487 | 0.1526 | 1.5013 | 1.2580 | 0.00 | 8760.00 | 1067.33 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 102825.66 | 102825.66 | 818502.78 | 8076.37 | 46.13 | 637.50 | 634.00 |
| SPLIT GNW | 0.00 | 100678.38 | 100678.38 | 818502.78 | 8130.62 | 54.76 | 574.62 | 0.00 |
| SPLIT OFFICE | 1705670.64 | 0.00 | 1705670.64 | 1201711.97 | 0.00 | 0.00 | 8760.00 | 7010.00 |
| SPLIT GNE | 0.00 | 101754.45 | 101754.45 | 818502.78 | 8098.44 | 45.67 | 615.89 | 0.00 |
| SPLIT GN1 | 0.00 | 100959.46 | 100959.46 | 818502.78 | 8121.08 | 50.64 | 588.28 | 0.00 |
| SPLIT GN2 | 0.00 | 101053.16 | 101053.16 | 818502.78 | 8117.26 | 50.41 | 592.33 | 0.00 |
| SPLIT GS1 | 0.00 | 103171.70 | 103171.70 | 818502.78 | 8066.67 | 45.42 | 647.92 | 634.00 |
| SPLIT GS2 | 0.00 | 103279.62 | 103279.62 | 818502.78 | 8064.80 | 44.03 | 651.17 | 634.00 |
| SPLIT MSW | 0.00 | 114277.12 | 114277.12 | 1637005.55 | 8755.17 | 1.33 | 3.50 | 634.00 |
| SPLIT MNW | 0.00 | 115600.75 | 115600.75 | 1637005.55 | 8755.83 | 1.00 | 3.17 | 0.00 |
| SPLIT MSE | 0.00 | 114293.42 | 114293.42 | 1637005.55 | 8755.17 | 1.33 | 3.50 | 634.00 |
| SPLIT MNE | 0.00 | 115899.88 | 115899.88 | 1637005.55 | 8755.58 | 1.08 | 3.33 | 0.00 |
| SPLIT MN1 | 0.00 | 115762.27 | 115762.27 | 1637005.55 | 8755.67 | 1.17 | 3.17 | 0.00 |
| SPLIT MN2 | 0.00 | 115789.69 | 115789.69 | 1637005.55 | 8755.58 | 1.25 | 3.17 | 0.00 |
| SPLIT MS1 | 0.00 | 114310.26 | 114310.26 | 1637005.55 | 8755.17 | 1.33 | 3.50 | 634.00 |
| SPLIT MS2 | 0.00 | 114310.52 | 114310.52 | 1637005.55 | 8755.17 | 1.33 | 3.50 | 634.00 |
| SPLIT TSW | 0.00 | 126337.59 | 126337.59 | 818502.78 | 7840.58 | 21.08 | 898.33 | 633.67 |
| SPLIT TNW | 0.00 | 127829.83 | 127829.83 | 818502.78 | 7820.53 | 16.22 | 923.25 | 0.00 |
| SPLIT TSE | 0.00 | 127028.03 | 127028.03 | 818502.78 | 7833.50 | 17.57 | 908.93 | 633.67 |
| SPLIT TNE | 0.00 | 129293.47 | 129293.47 | 818502.78 | 7806.92 | 14.36 | 938.72 | 0.00 |
| SPLIT TN1 | 0.00 | 128224.07 | 128224.07 | 818502.78 | 7813.75 | 17.02 | 929.22 | 0.00 |
| SPLIT TN2 | 0.00 | 128357.96 | 128357.96 | 818502.78 | 7812.47 | 17.06 | 930.47 | 0.00 |
| SPLIT TS1 | 0.00 | 126774.96 | 126774.96 | 818502.78 | 7834.37 | 19.98 | 905.65 | 633.67 |
| SPLIT TS2 | 0.00 | 126808.83 | 126808.83 | 818502.78 | 7834.20 | 20.07 | 905.73 | 633.67 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0019 | 0.0019 | 0.0260 | 5830.33 | 16.08 | 298.58 |
| SPLIT GNW | 0.0000 | 0.0032 | 0.0032 | 0.0260 | 8130.62 | 54.76 | 574.62 |
| SPLIT OFFICE | 0.0541 | 0.0000 | 0.0541 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0032 | 0.0032 | 0.0260 | 8098.44 | 45.67 | 615.89 |
| SPLIT GN1 | 0.0000 | 0.0032 | 0.0032 | 0.0260 | 8121.08 | 50.64 | 588.28 |
| SPLIT GN2 | 0.0000 | 0.0032 | 0.0032 | 0.0260 | 8117.26 | 50.41 | 592.33 |
| SPLIT GS1 | 0.0000 | 0.0019 | 0.0019 | 0.0260 | 5829.33 | 14.92 | 300.75 |
| SPLIT GS2 | 0.0000 | 0.0019 | 0.0019 | 0.0260 | 5828.63 | 15.20 | 301.17 |
| SPLIT MSW | 0.0000 | 0.0021 | 0.0021 | 0.0519 | 6144.00 | 0.33 | 0.67 |
| SPLIT MNW | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 8755.83 | 1.00 | 3.17 |
| SPLIT MSE | 0.0000 | 0.0021 | 0.0021 | 0.0519 | 6144.00 | 0.33 | 0.67 |
| SPLIT MNE | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 8755.58 | 1.08 | 3.33 |
| SPLIT MN1 | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 8755.67 | 1.17 | 3.17 |
| SPLIT MN2 | 0.0000 | 0.0037 | 0.0037 | 0.0519 | 8755.58 | 1.25 | 3.17 |
| SPLIT MS1 | 0.0000 | 0.0021 | 0.0021 | 0.0519 | 6144.00 | 0.33 | 0.67 |
| SPLIT MS2 | 0.0000 | 0.0021 | 0.0021 | 0.0519 | 6144.00 | 0.33 | 0.67 |
| SPLIT TSW | 0.0000 | 0.0023 | 0.0023 | 0.0260 | 5765.04 | 7.46 | 372.50 |
| SPLIT TNW | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 7820.53 | 16.22 | 923.25 |
| SPLIT TSE | 0.0000 | 0.0024 | 0.0024 | 0.0260 | 5761.17 | 6.23 | 377.60 |
| SPLIT TNE | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 7806.92 | 14.36 | 938.72 |
| SPLIT TN1 | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 7813.75 | 17.02 | 929.22 |
| SPLIT TN2 | 0.0000 | 0.0041 | 0.0041 | 0.0260 | 7812.47 | 17.06 | 930.47 |
| SPLIT TS1 | 0.0000 | 0.0023 | 0.0023 | 0.0260 | 5762.70 | 6.65 | 375.65 |
| SPLIT TS2 | 0.0000 | 0.0023 | 0.0023 | 0.0260 | 5762.53 | 6.73 | 375.73 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0541 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1536 |
| Defaulted Fields | 1816 |
| Fields with Defaults | 5921 |
| Autosized Fields | 617 |
| Autosizable Fields | 759 |
| Autocalculated Fields | 331 |
| Autocalculatable Fields | 508 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| Electricity:Building | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| Electricity:Zone:G SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 557.89 | 10119.94 | 01-JAN-03:10 | 27841.36 | 01-JAN-18:10 |
| InteriorLights:Electricity | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 99.23 | 1868.27 | 01-JAN-00:10 | 5904.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 94.96 | 1842.77 | 01-JAN-00:10 | 5496.56 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 16.86 | 310.83 | 01-JAN-00:10 | 1171.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 7.40 | 116.58 | 01-JAN-00:10 | 582.92 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 27.33 | 464.72 | 01-JAN-03:10 | 1411.61 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.91 | 17.37 | 01-JAN-00:10 | 277.76 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.63 | 15.72 | 01-JAN-00:10 | 251.45 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.67 | 232.36 | 01-JAN-03:10 | 705.80 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.45 | 8.68 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.32 | 7.86 | 01-JAN-00:10 | 125.72 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 82.28 | 1494.09 | 01-JAN-00:10 | 4538.70 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 23.38 | 741.26 | 01-JAN-00:10 | 741.26 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 11.69 | 370.63 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 4.27 | 25.50 | 01-JAN-00:10 | 407.87 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.28 | 1.65 | 01-JAN-00:10 | 26.31 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.14 | 0.82 | 01-JAN-00:10 | 13.16 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 458.66 | 8251.68 | 01-JAN-03:10 | 22709.69 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 388.06 | 7128.22 | 01-JAN-03:10 | 18541.61 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 9.47 | 194.25 | 01-JAN-00:10 | 588.62 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 70.59 | 1123.46 | 01-JAN-00:10 | 4168.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 65.48 | 961.46 | 01-JAN-00:10 | 4006.07 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 5.11 | 162.00 | 01-JAN-00:10 | 162.00 | 01-JAN-00:10 |
| Fans:Electricity | 71.54 | 1653.97 | 16-MAY-17:10 | 6881.08 | 22-JUL-16:10 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| ElectricityPurchased:Plant | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| Cogeneration:ElectricityPurchased | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| General:Cogeneration:ElectricityPurchased | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| ElectricityNet:Plant | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| Cogeneration:ElectricityNet | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| General:Cogeneration:ElectricityNet | 1190.91 | 16756.99 | 22-JUN-04:50 | 80097.91 | 22-JUL-17:30 |
| Electricity:HVAC | 104.64 | 1653.97 | 16-MAY-17:10 | 24838.49 | 22-JUL-16:10 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 71.54 | 1653.97 | 16-MAY-17:10 | 6881.08 | 22-JUL-16:10 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:Electricity | 33.10 | 0.00 | 01-JAN-00:10 | 17957.41 | 22-JUL-16:10 |
| General:Cooling:Electricity | 33.10 | 0.00 | 01-JAN-00:10 | 17957.41 | 22-JUL-16:10 |
| ExteriorLights:Electricity | 49.92 | 0.00 | 01-JAN-08:20 | 3183.33 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 49.92 | 0.00 | 01-JAN-08:20 | 3183.33 | 01-JAN-00:10 |
| Electricity:Plant | 478.47 | 1950.00 | 01-JAN-00:10 | 37826.41 | 05-FEB-07:20 |
| WaterSystems:Electricity | 478.47 | 1950.00 | 01-JAN-00:10 | 37826.41 | 05-FEB-07:20 |
| Water Heater:WaterSystems:Electricity | 478.47 | 1950.00 | 01-JAN-00:10 | 37826.41 | 05-FEB-07:20 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 270.62 | 0.00 | 02-APR-15:20 | 54764.95 | 10-JAN-06:00 |
| NaturalGas:HVAC | 270.62 | 0.00 | 02-APR-15:20 | 54764.95 | 10-JAN-06:00 |
| Heating:NaturalGas | 270.62 | 0.00 | 02-APR-15:20 | 54764.95 | 10-JAN-06:00 |
| General:Heating:NaturalGas | 270.62 | 0.00 | 02-APR-15:20 | 54764.95 | 10-JAN-06:00 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:MainsWater | 1875.32 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 751.74 | 5038.93 | 17-OCT-14:20 | 125594.79 | 22-JUL-16:10 |
| EnergyTransfer:Building | 404.70 | 3817.75 | 24-NOV-12:00 | 57638.81 | 22-JUL-16:10 |
| EnergyTransfer:Zone:G SW APARTMENT | 10.49 | 0.00 | 23-NOV-11:00 | 1870.49 | 22-JUL-16:30 |
| Heating:EnergyTransfer | 65.77 | 0.00 | 18-JAN-19:00 | 22272.28 | 30-DEC-02:00 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 2.57 | 0.00 | 01-JAN-09:50 | 798.97 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer | 65.77 | 0.00 | 18-JAN-19:00 | 22272.28 | 30-DEC-02:00 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 2.57 | 0.00 | 01-JAN-09:50 | 798.97 | 10-JAN-06:00 |
| Cooling:EnergyTransfer | 338.92 | 0.00 | 14-DEC-13:50 | 57224.90 | 22-JUL-16:10 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 7.93 | 0.00 | 01-JAN-00:10 | 1870.49 | 22-JUL-16:30 |
| General:Cooling:EnergyTransfer | 338.92 | 0.00 | 14-DEC-13:50 | 57224.90 | 22-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 7.93 | 0.00 | 01-JAN-00:10 | 1870.49 | 22-JUL-16:30 |
| EnergyTransfer:Zone:G NW APARTMENT | 9.30 | 0.00 | 19-OCT-09:40 | 1495.59 | 22-JUL-18:30 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 4.63 | 0.00 | 17-JAN-16:10 | 1004.78 | 10-JAN-09:00 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 4.63 | 0.00 | 17-JAN-16:10 | 1004.78 | 10-JAN-09:00 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 4.67 | 0.00 | 01-JAN-00:10 | 1495.59 | 22-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 4.67 | 0.00 | 01-JAN-00:10 | 1495.59 | 22-JUL-18:30 |
| EnergyTransfer:Zone:OFFICE | 9.54 | 0.00 | 18-JAN-13:40 | 2623.86 | 24-JUL-13:00 |
| Heating:EnergyTransfer:Zone:OFFICE | 1.22 | 0.00 | 01-JAN-00:10 | 2165.38 | 09-JAN-08:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 1.22 | 0.00 | 01-JAN-00:10 | 2165.38 | 09-JAN-08:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 8.32 | 0.00 | 03-JAN-07:30 | 2623.86 | 24-JUL-13:00 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 8.32 | 0.00 | 03-JAN-07:30 | 2623.86 | 24-JUL-13:00 |
| EnergyTransfer:Zone:G NE APARTMENT | 9.24 | 0.05 | 04-NOV-13:50 | 1153.54 | 22-JUL-18:30 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 4.55 | 0.00 | 18-JAN-19:00 | 990.30 | 11-JAN-05:00 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 4.55 | 0.00 | 18-JAN-19:00 | 990.30 | 11-JAN-05:00 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.69 | 0.00 | 01-JAN-00:10 | 1153.54 | 22-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.69 | 0.00 | 01-JAN-00:10 | 1153.54 | 22-JUL-18:30 |
| EnergyTransfer:Zone:G N1 APARTMENT | 6.62 | 0.01 | 22-NOV-00:30 | 959.14 | 22-JUL-18:40 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 1.19 | 0.00 | 06-JAN-17:10 | 512.38 | 12-JAN-02:10 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 1.19 | 0.00 | 06-JAN-17:10 | 512.38 | 12-JAN-02:10 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 5.43 | 0.00 | 01-JAN-00:10 | 959.14 | 22-JUL-18:40 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 5.43 | 0.00 | 01-JAN-00:10 | 959.14 | 22-JUL-18:40 |
| EnergyTransfer:Zone:G N2 APARTMENT | 6.63 | 0.00 | 21-FEB-22:50 | 951.81 | 22-JUL-18:40 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 1.18 | 0.00 | 06-JAN-17:10 | 512.81 | 12-JAN-02:10 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 1.18 | 0.00 | 06-JAN-17:10 | 512.81 | 12-JAN-02:10 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 5.45 | 0.00 | 01-JAN-00:10 | 951.81 | 22-JUL-18:40 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 5.45 | 0.00 | 01-JAN-00:10 | 951.81 | 22-JUL-18:40 |
| EnergyTransfer:Zone:G S1 APARTMENT | 10.12 | 0.01 | 25-FEB-01:30 | 1384.68 | 22-JUL-16:10 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.32 | 0.00 | 01-JAN-00:10 | 317.06 | 30-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.32 | 0.00 | 01-JAN-00:10 | 317.06 | 30-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 9.80 | 0.00 | 03-JAN-02:40 | 1384.68 | 22-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 9.80 | 0.00 | 03-JAN-02:40 | 1384.68 | 22-JUL-16:10 |
| EnergyTransfer:Zone:G S2 APARTMENT | 10.36 | 0.02 | 29-MAR-00:40 | 1468.56 | 22-JUL-16:10 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.59 | 0.00 | 01-JAN-00:20 | 400.60 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.59 | 0.00 | 01-JAN-00:20 | 400.60 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 9.78 | 0.00 | 01-JAN-00:10 | 1468.56 | 22-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 9.78 | 0.00 | 01-JAN-00:10 | 1468.56 | 22-JUL-16:10 |
| EnergyTransfer:Zone:M SW APARTMENT | 31.54 | 0.04 | 02-JAN-04:30 | 5117.54 | 30-APR-16:10 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 1.27 | 0.00 | 01-JAN-00:10 | 1256.44 | 28-DEC-02:00 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 1.27 | 0.00 | 01-JAN-00:10 | 1256.44 | 28-DEC-02:00 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 30.28 | 0.00 | 01-JAN-06:00 | 5117.54 | 30-APR-16:10 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 30.28 | 0.00 | 01-JAN-06:00 | 5117.54 | 30-APR-16:10 |
| EnergyTransfer:Zone:M NW APARTMENT | 22.13 | 0.01 | 09-MAR-07:30 | 4321.52 | 13-JUN-17:30 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 2.69 | 0.00 | 01-JAN-20:40 | 1492.02 | 30-DEC-02:00 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 2.69 | 0.00 | 01-JAN-20:40 | 1492.02 | 30-DEC-02:00 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 19.44 | 0.00 | 01-JAN-00:10 | 4321.52 | 13-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 19.44 | 0.00 | 01-JAN-00:10 | 4321.52 | 13-JUN-17:30 |
| EnergyTransfer:Zone:M SE APARTMENT | 31.90 | 0.10 | 07-FEB-07:00 | 4563.02 | 22-JUL-13:30 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 1.24 | 0.00 | 01-JAN-00:10 | 1262.31 | 30-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 1.24 | 0.00 | 01-JAN-00:10 | 1262.31 | 30-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 30.66 | 0.00 | 03-JAN-01:10 | 4563.02 | 22-JUL-13:30 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 30.66 | 0.00 | 03-JAN-01:10 | 4563.02 | 22-JUL-13:30 |
| EnergyTransfer:Zone:M NE APARTMENT | 22.18 | 0.04 | 27-JAN-07:30 | 3235.15 | 22-JUL-18:30 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 2.60 | 0.00 | 01-JAN-09:30 | 1531.50 | 30-DEC-02:00 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 2.60 | 0.00 | 01-JAN-09:30 | 1531.50 | 30-DEC-02:00 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 19.59 | 0.00 | 01-JAN-00:10 | 3235.15 | 22-JUL-18:30 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 19.59 | 0.00 | 01-JAN-00:10 | 3235.15 | 22-JUL-18:30 |
| EnergyTransfer:Zone:M N1 APARTMENT | 22.32 | 0.08 | 23-DEC-07:00 | 2609.73 | 22-JUL-18:40 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.16 | 0.00 | 01-JAN-00:10 | 510.24 | 30-DEC-02:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.16 | 0.00 | 01-JAN-00:10 | 510.24 | 30-DEC-02:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 22.17 | 0.00 | 04-JAN-00:10 | 2609.73 | 22-JUL-18:40 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 22.17 | 0.00 | 04-JAN-00:10 | 2609.73 | 22-JUL-18:40 |
| EnergyTransfer:Zone:M N2 APARTMENT | 22.36 | 0.03 | 16-DEC-15:10 | 2591.80 | 22-JUL-18:40 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.16 | 0.00 | 01-JAN-00:10 | 511.47 | 30-DEC-02:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.16 | 0.00 | 01-JAN-00:10 | 511.47 | 30-DEC-02:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 22.20 | 0.00 | 04-JAN-00:10 | 2591.80 | 22-JUL-18:40 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 22.20 | 0.00 | 04-JAN-00:10 | 2591.80 | 22-JUL-18:40 |
| EnergyTransfer:Zone:M S1 APARTMENT | 33.96 | 0.02 | 01-DEC-03:50 | 3815.73 | 27-SEP-13:30 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 318.35 | 30-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 318.35 | 30-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 33.93 | 0.00 | 04-JAN-02:10 | 3815.73 | 27-SEP-13:30 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 33.93 | 0.00 | 04-JAN-02:10 | 3815.73 | 27-SEP-13:30 |
| EnergyTransfer:Zone:M S2 APARTMENT | 34.00 | 0.07 | 16-FEB-04:50 | 3824.01 | 27-SEP-13:30 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 319.65 | 30-DEC-04:00 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.03 | 0.00 | 01-JAN-00:10 | 319.65 | 30-DEC-04:00 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 33.97 | 0.00 | 04-JAN-02:10 | 3824.01 | 27-SEP-13:30 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 33.97 | 0.00 | 04-JAN-02:10 | 3824.01 | 27-SEP-13:30 |
| EnergyTransfer:Zone:T SW APARTMENT | 17.43 | 0.09 | 01-MAR-19:20 | 3495.61 | 22-JUL-16:10 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 6.21 | 0.00 | 01-JAN-10:00 | 1667.25 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 6.21 | 0.00 | 01-JAN-10:00 | 1667.25 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 11.22 | 0.00 | 01-JAN-00:10 | 3495.61 | 22-JUL-16:10 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 11.22 | 0.00 | 01-JAN-00:10 | 3495.61 | 22-JUL-16:10 |
| EnergyTransfer:Zone:T NW APARTMENT | 14.90 | 0.02 | 22-OCT-19:50 | 2941.59 | 13-JUN-17:30 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 8.19 | 0.00 | 15-JAN-12:40 | 1737.12 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 8.19 | 0.00 | 15-JAN-12:40 | 1737.12 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 6.70 | 0.00 | 01-JAN-00:10 | 2941.59 | 13-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 6.70 | 0.00 | 01-JAN-00:10 | 2941.59 | 13-JUN-17:30 |
| EnergyTransfer:Zone:T SE APARTMENT | 17.39 | 0.05 | 20-OCT-11:40 | 3152.74 | 22-JUL-13:30 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 6.14 | 0.00 | 01-JAN-09:30 | 1681.61 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 6.14 | 0.00 | 01-JAN-09:30 | 1681.61 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 11.25 | 0.00 | 01-JAN-00:10 | 3152.74 | 22-JUL-13:30 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 11.25 | 0.00 | 01-JAN-00:10 | 3152.74 | 22-JUL-13:30 |
| EnergyTransfer:Zone:T NE APARTMENT | 14.58 | 0.01 | 08-NOV-20:40 | 2164.03 | 22-JUL-16:20 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 8.06 | 0.00 | 06-JAN-11:50 | 1750.57 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 8.06 | 0.00 | 06-JAN-11:50 | 1750.57 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 6.52 | 0.00 | 01-JAN-00:10 | 2164.03 | 22-JUL-16:20 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 6.52 | 0.00 | 01-JAN-00:10 | 2164.03 | 22-JUL-16:20 |
| EnergyTransfer:Zone:T N1 APARTMENT | 10.09 | 0.00 | 12-NOV-12:50 | 1769.28 | 22-JUL-16:30 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 3.86 | 0.00 | 06-JAN-12:00 | 1108.11 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 3.86 | 0.00 | 06-JAN-12:00 | 1108.11 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 6.23 | 0.00 | 01-JAN-00:10 | 1769.28 | 22-JUL-16:30 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 6.23 | 0.00 | 01-JAN-00:10 | 1769.28 | 22-JUL-16:30 |
| EnergyTransfer:Zone:T N2 APARTMENT | 10.12 | 0.01 | 18-JAN-11:00 | 1755.32 | 22-JUL-16:20 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 3.86 | 0.00 | 06-JAN-11:50 | 1108.81 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 3.86 | 0.00 | 06-JAN-11:50 | 1108.81 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 6.25 | 0.00 | 01-JAN-00:10 | 1755.32 | 22-JUL-16:20 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 6.25 | 0.00 | 01-JAN-00:10 | 1755.32 | 22-JUL-16:20 |
| EnergyTransfer:Zone:T S1 APARTMENT | 13.72 | 0.05 | 09-MAY-03:30 | 2630.72 | 22-JUL-13:50 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 2.51 | 0.00 | 01-JAN-09:10 | 1031.60 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 2.51 | 0.00 | 01-JAN-09:10 | 1031.60 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 11.21 | 0.00 | 01-JAN-00:10 | 2630.72 | 22-JUL-13:50 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 11.21 | 0.00 | 01-JAN-00:10 | 2630.72 | 22-JUL-13:50 |
| EnergyTransfer:Zone:T S2 APARTMENT | 13.77 | 0.06 | 19-MAR-01:50 | 2639.51 | 22-JUL-13:50 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 2.51 | 0.00 | 01-JAN-09:10 | 1032.43 | 10-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 2.51 | 0.00 | 01-JAN-09:10 | 1032.43 | 10-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 11.26 | 0.00 | 01-JAN-00:10 | 2639.51 | 22-JUL-13:50 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 11.26 | 0.00 | 01-JAN-00:10 | 2639.51 | 22-JUL-13:50 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:HVAC | 347.05 | 0.00 | 02-APR-15:20 | 67955.99 | 22-JUL-16:10 |
| HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 29-JAN-04:10 |
| HeatRecoveryForCooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 28-APR-13:50 |
| HeatingCoils:EnergyTransfer | 216.50 | 0.00 | 02-APR-15:20 | 43811.96 | 10-JAN-06:00 |
| CoolingCoils:EnergyTransfer | 130.55 | 0.00 | 01-JAN-00:10 | 67955.99 | 22-JUL-16:10 |
| PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 0.013 | -12.144 | 9.097 | -2.322 | 0.000 | 0.000 | 3.955 | 1.454 | 12.213 | 10.545 | 0.000 | 0.002 | 0.000 | 0.000 | -6.187 | 0.000 | -2.658 | -13.968 |
| G NW APARTMENT | 0.013 | -11.856 | 12.449 | -0.651 | 0.000 | 0.000 | 4.061 | 1.454 | 12.213 | 5.236 | 0.000 | 0.002 | 0.000 | 0.000 | -6.118 | 0.000 | -2.536 | -14.267 |
| OFFICE | 0.000 | 0.000 | 1.224 | -8.315 | 0.000 | 0.000 | 2.170 | 7.396 | 9.469 | 10.612 | 0.000 | 0.000 | 0.000 | 0.000 | -5.886 | 0.000 | -1.894 | -14.776 |
| G NE APARTMENT | 0.013 | -11.884 | 12.320 | -0.580 | 0.000 | 0.000 | 4.061 | 1.454 | 12.213 | 5.246 | 0.000 | 0.002 | 0.000 | 0.000 | -5.981 | 0.000 | -2.563 | -14.301 |
| G N1 APARTMENT | 0.013 | -11.930 | 8.086 | -0.418 | 0.000 | 0.000 | 4.045 | 1.454 | 12.213 | 1.753 | 0.000 | 0.001 | 0.000 | 0.000 | -3.817 | 0.000 | -1.815 | -9.586 |
| G N2 APARTMENT | 0.013 | -11.934 | 8.079 | -0.421 | 0.000 | 0.000 | 4.044 | 1.454 | 12.213 | 1.752 | 0.000 | 0.001 | 0.000 | 0.000 | -3.817 | 0.000 | -1.817 | -9.567 |
| G S1 APARTMENT | 0.013 | -12.278 | 5.112 | -2.326 | 0.000 | 0.000 | 3.927 | 1.454 | 12.213 | 7.136 | 0.000 | 0.001 | 0.000 | 0.000 | -3.845 | 0.000 | -1.923 | -9.483 |
| G S2 APARTMENT | 0.013 | -12.292 | 5.677 | -2.586 | 0.000 | 0.000 | 3.923 | 1.454 | 12.213 | 7.133 | 0.000 | 0.001 | 0.000 | 0.000 | -3.841 | 0.000 | -1.928 | -9.767 |
| M SW APARTMENT | 0.026 | -25.120 | 8.843 | -12.759 | 0.000 | 0.000 | 7.740 | 2.908 | 24.426 | 20.535 | 0.000 | 0.005 | 0.000 | 0.000 | -13.143 | 0.000 | -7.392 | -6.069 |
| M NW APARTMENT | 0.026 | -24.619 | 13.883 | -6.040 | 0.000 | 0.000 | 7.931 | 2.908 | 24.426 | 9.896 | 0.000 | 0.005 | 0.000 | 0.000 | -13.064 | 0.000 | -7.275 | -8.076 |
| M SE APARTMENT | 0.026 | -25.156 | 8.786 | -13.074 | 0.000 | 0.000 | 7.738 | 2.908 | 24.426 | 20.627 | 0.000 | 0.005 | 0.000 | 0.000 | -12.914 | 0.000 | -7.402 | -5.970 |
| M NE APARTMENT | 0.026 | -24.683 | 13.780 | -6.114 | 0.000 | 0.000 | 7.928 | 2.908 | 24.426 | 9.899 | 0.000 | 0.005 | 0.000 | 0.000 | -12.765 | 0.000 | -7.309 | -8.101 |
| M N1 APARTMENT | 0.026 | -24.843 | 7.373 | -4.566 | 0.000 | 0.000 | 7.883 | 2.908 | 24.426 | 3.201 | 0.000 | 0.003 | 0.000 | 0.000 | -8.139 | 0.000 | -5.099 | -3.173 |
| M N2 APARTMENT | 0.026 | -24.851 | 7.371 | -4.593 | 0.000 | 0.000 | 7.882 | 2.908 | 24.426 | 3.198 | 0.000 | 0.003 | 0.000 | 0.000 | -8.141 | 0.000 | -5.102 | -3.127 |
| M S1 APARTMENT | 0.026 | -25.524 | 3.346 | -11.742 | 0.000 | 0.000 | 7.658 | 2.908 | 24.426 | 13.973 | 0.000 | 0.003 | 0.001 | 0.000 | -8.166 | 0.000 | -5.182 | -1.726 |
| M S2 APARTMENT | 0.026 | -25.527 | 3.345 | -11.784 | 0.000 | 0.000 | 7.657 | 2.908 | 24.426 | 13.972 | 0.000 | 0.003 | 0.001 | 0.000 | -8.167 | 0.000 | -5.182 | -1.677 |
| T SW APARTMENT | 0.013 | -12.087 | 12.987 | -5.930 | 0.000 | 0.000 | 3.983 | 1.454 | 12.213 | 10.322 | 0.000 | 0.003 | 0.000 | 0.000 | -6.113 | 0.000 | -4.537 | -12.310 |
| T NW APARTMENT | 0.013 | -11.875 | 16.077 | -2.724 | 0.000 | 0.000 | 4.063 | 1.454 | 12.213 | 5.042 | 0.000 | 0.003 | 0.000 | 0.000 | -6.115 | 0.000 | -4.434 | -13.718 |
| T SE APARTMENT | 0.013 | -12.123 | 12.844 | -5.844 | 0.000 | 0.000 | 3.984 | 1.454 | 12.213 | 10.373 | 0.000 | 0.003 | 0.000 | 0.000 | -6.016 | 0.000 | -4.569 | -12.332 |
| T NE APARTMENT | 0.013 | -11.932 | 15.904 | -2.450 | 0.000 | 0.000 | 4.063 | 1.454 | 12.213 | 5.041 | 0.000 | 0.003 | 0.000 | 0.000 | -5.978 | 0.000 | -4.498 | -13.833 |
| T N1 APARTMENT | 0.013 | -11.945 | 11.132 | -1.562 | 0.000 | 0.000 | 4.048 | 1.454 | 12.213 | 1.669 | 0.000 | 0.002 | 0.000 | 0.000 | -3.814 | 0.000 | -3.048 | -10.163 |
| T N2 APARTMENT | 0.013 | -11.951 | 11.129 | -1.579 | 0.000 | 0.000 | 4.047 | 1.454 | 12.213 | 1.665 | 0.000 | 0.002 | 0.000 | 0.000 | -3.813 | 0.000 | -3.053 | -10.126 |
| T S1 APARTMENT | 0.013 | -12.217 | 8.238 | -4.734 | 0.000 | 0.000 | 3.955 | 1.454 | 12.213 | 7.032 | 0.000 | 0.002 | 0.000 | 0.000 | -3.799 | 0.000 | -3.135 | -9.023 |
| T S2 APARTMENT | 0.013 | -12.219 | 8.239 | -4.774 | 0.000 | 0.000 | 3.956 | 1.454 | 12.213 | 7.030 | 0.000 | 0.002 | 0.000 | 0.000 | -3.798 | 0.000 | -3.136 | -8.980 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.570 | 11.688 | 0.000 | 0.827 | 0.000 | 0.000 | 0.000 | 0.000 | -0.620 | 0.000 | -0.660 | -17.805 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.982 | 11.688 | 3.530 | 2.551 | 0.000 | 0.013 | 7.448 | 0.000 | -1.702 | 0.000 | -30.510 | -0.001 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 12.154 | 23.376 | 0.000 | 1.601 | 0.000 | 0.000 | 0.000 | 0.000 | -1.358 | 0.000 | -1.101 | -34.672 |
| Total Facility | 0.402 | -380.988 | 225.321 | -117.886 | 0.000 | 0.000 | 150.407 | 99.229 | 391.594 | 197.868 | 0.000 | 0.075 | 7.451 | 0.000 | -167.116 | 0.000 | -129.758 | -276.596 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 22-JUL-16:30 | 0.00 | 177.57 | 0.00 | -2048.06 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 1600.72 | 0.00 | 27.18 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -600.07 |
| G NW APARTMENT | 22-JUL-18:30 | 0.00 | 193.27 | 0.00 | -1688.89 | 0.00 | 0.00 | 145.49 | 138.88 | 547.42 | 1323.44 | 0.00 | 14.91 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -674.51 |
| OFFICE | 26-SEP-08:62 | 0.00 | 0.00 | 0.00 | -5598.31 | 0.00 | 0.00 | 288.42 | 582.92 | 588.62 | 478.10 | 0.00 | 0.00 | 3705.34 | 0.00 | -0.00 | 0.00 | -45.09 | 0.00 |
| G NE APARTMENT | 22-JUL-18:30 | 0.00 | 193.26 | 0.00 | -1346.83 | 0.00 | 0.00 | 145.49 | 138.88 | 547.42 | 526.98 | 0.00 | 14.91 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -220.10 |
| G N1 APARTMENT | 22-JUL-18:40 | 0.00 | 188.03 | 0.00 | -1147.20 | 0.00 | 0.00 | 145.49 | 138.88 | 547.42 | 376.76 | 0.00 | 11.63 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -261.01 |
| G N2 APARTMENT | 22-JUL-18:40 | 0.00 | 188.03 | 0.00 | -1139.87 | 0.00 | 0.00 | 145.49 | 138.88 | 547.42 | 376.85 | 0.00 | 11.63 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -268.43 |
| G S1 APARTMENT | 22-JUL-16:10 | 0.00 | 177.58 | 0.00 | -1562.34 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 512.55 | 0.00 | 16.39 | 13.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 22-JUL-16:10 | 0.00 | 177.58 | 0.00 | -1646.21 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 511.66 | 0.00 | 16.39 | 97.93 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 30-APR-16:10 | 0.00 | 40.07 | 0.00 | -5157.65 | 0.00 | 0.00 | 334.45 | 173.60 | 1177.25 | 3628.39 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -0.03 | -196.09 |
| M NW APARTMENT | 13-JUN-17:30 | 0.00 | 131.44 | 0.00 | -4452.88 | 0.00 | 0.00 | 290.97 | 234.36 | 1177.25 | 3422.75 | 0.00 | 27.02 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -830.91 |
| M SE APARTMENT | 22-JUL-13:30 | 0.00 | 292.13 | 0.00 | -4854.95 | 0.00 | 0.00 | 167.23 | 34.72 | 765.21 | 3284.97 | 0.00 | 86.52 | 224.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 22-JUL-18:30 | 0.00 | 386.51 | 0.00 | -3621.74 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 1041.56 | 0.00 | 42.70 | 487.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 22-JUL-18:40 | 0.00 | 376.04 | 0.00 | -2985.85 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 746.49 | 0.00 | 33.31 | 166.43 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 22-JUL-18:40 | 0.00 | 376.04 | 0.00 | -2967.92 | 0.00 | 0.00 | 290.97 | 277.76 | 1094.84 | 746.64 | 0.00 | 33.31 | 148.35 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 27-SEP-13:30 | 0.00 | -117.27 | 0.00 | -3698.10 | 0.00 | 0.00 | 0.00 | 34.72 | 765.21 | 3834.78 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -146.71 | -672.63 |
| M S2 APARTMENT | 27-SEP-13:30 | 0.00 | -117.27 | 0.00 | -3706.38 | 0.00 | 0.00 | 0.00 | 34.72 | 765.21 | 3834.71 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -146.71 | -664.28 |
| T SW APARTMENT | 22-JUL-16:10 | 0.00 | 177.55 | 0.00 | -3673.23 | 0.00 | 0.00 | 167.23 | 86.80 | 588.62 | 1658.98 | 0.00 | 51.05 | 943.00 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 13-JUN-17:30 | 0.00 | 65.70 | 0.00 | -3007.24 | 0.00 | 0.00 | 145.49 | 117.18 | 588.62 | 1688.79 | 0.00 | 17.38 | 384.08 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 22-JUL-13:30 | 0.00 | 146.05 | 0.00 | -3298.69 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1619.28 | 0.00 | 56.66 | 993.12 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 22-JUL-16:20 | 0.00 | 177.50 | 0.00 | -2341.64 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 557.27 | 0.00 | 51.05 | 793.44 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 22-JUL-16:30 | 0.00 | 177.51 | 0.00 | -1946.75 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 332.74 | 0.00 | 30.79 | 643.32 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 22-JUL-16:20 | 0.00 | 177.52 | 0.00 | -1932.94 | 0.00 | 0.00 | 86.96 | 86.80 | 588.62 | 340.35 | 0.00 | 30.79 | 621.90 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 22-JUL-13:50 | 0.00 | 146.06 | 0.00 | -2776.71 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1283.81 | 0.00 | 34.16 | 829.10 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 22-JUL-13:50 | 0.00 | 146.06 | 0.00 | -2785.50 | 0.00 | 0.00 | 83.61 | 17.36 | 382.60 | 1283.72 | 0.00 | 34.16 | 837.98 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 22-JUL-16:10 | -414.46 | 5918.34 | 414.46 | -62729.01 | 0.00 | 0.00 | 4374.78 | 4289.87 | 18649.95 | 25218.44 | 0.00 | 1746.66 | 2531.10 | 0.00 | 0.00 | 0.00 | -0.13 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 10-JAN-06:00 | -763.84 | 0.00 | 1562.81 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -554.31 | 0.00 | -181.89 | -567.28 |
| G NW APARTMENT | 10-JAN-09:00 | -763.47 | 0.00 | 1768.23 | 0.00 | 0.00 | 0.00 | 76.05 | 26.04 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -459.57 | 0.00 | -152.84 | -882.93 |
| OFFICE | 20-MAR-07:01 | 0.00 | 0.00 | 8932.61 | 0.00 | 0.00 | 0.00 | 413.65 | 582.92 | 588.62 | 24.80 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -70.90 | -10471.70 |
| G NE APARTMENT | 11-JAN-05:00 | -731.54 | 0.00 | 1721.87 | 0.00 | 0.00 | 0.00 | 194.99 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -514.00 | 0.00 | -145.62 | -775.41 |
| G N1 APARTMENT | 12-JAN-02:70 | -764.12 | 0.00 | 1276.50 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -333.49 | 0.00 | -53.48 | -558.65 |
| G N2 APARTMENT | 12-JAN-02:70 | -764.12 | 0.00 | 1276.93 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -333.49 | 0.00 | -53.48 | -559.08 |
| G S1 APARTMENT | 30-DEC-04:00 | -701.27 | 0.00 | 1018.33 | 0.00 | 0.00 | 0.00 | 194.99 | 8.68 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -322.18 | 0.00 | -117.32 | -304.91 |
| G S2 APARTMENT | 10-JAN-06:00 | -763.88 | 0.00 | 1164.48 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -338.58 | 0.00 | -109.71 | -456.83 |
| M SW APARTMENT | 28-DEC-02:00 | -1156.18 | 0.00 | 2412.60 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 482.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -911.40 | 0.00 | -786.41 | -448.64 |
| M NW APARTMENT | 30-DEC-02:00 | -1402.19 | 0.00 | 2894.19 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 482.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1055.33 | 0.00 | -637.22 | -689.48 |
| M SE APARTMENT | 30-DEC-04:00 | -1402.35 | 0.00 | 2664.67 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1067.49 | 0.00 | -559.54 | -490.00 |
| M NE APARTMENT | 30-DEC-02:00 | -1402.19 | 0.00 | 2933.67 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 482.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1043.54 | 0.00 | -637.22 | -740.75 |
| M N1 APARTMENT | 30-DEC-02:00 | -1402.33 | 0.00 | 1912.56 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 482.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -638.99 | 0.00 | -384.35 | -376.91 |
| M N2 APARTMENT | 30-DEC-02:00 | -1402.33 | 0.00 | 1913.80 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 482.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -638.96 | 0.00 | -384.35 | -378.17 |
| M S1 APARTMENT | 30-DEC-04:00 | -1402.47 | 0.00 | 1720.83 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -660.92 | 0.00 | -337.50 | -174.64 |
| M S2 APARTMENT | 30-DEC-04:00 | -1402.47 | 0.00 | 1722.12 | 0.00 | 0.00 | 0.00 | 389.98 | 17.37 | 447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -660.90 | 0.00 | -337.50 | -175.96 |
| T SW APARTMENT | 10-JAN-06:00 | -763.76 | 0.00 | 2431.00 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -547.67 | 0.00 | -346.59 | -1277.50 |
| T NW APARTMENT | 10-JAN-06:00 | -763.76 | 0.00 | 2500.88 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -554.73 | 0.00 | -346.59 | -1340.30 |
| T SE APARTMENT | 10-JAN-06:00 | -763.76 | 0.00 | 2445.37 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -553.10 | 0.00 | -346.59 | -1286.43 |
| T NE APARTMENT | 10-JAN-06:00 | -763.76 | 0.00 | 2514.33 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -560.17 | 0.00 | -346.59 | -1348.32 |
| T N1 APARTMENT | 10-JAN-06:00 | -763.83 | 0.00 | 1871.93 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -343.17 | 0.00 | -209.06 | -1060.39 |
| T N2 APARTMENT | 10-JAN-06:00 | -763.83 | 0.00 | 1872.63 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -343.16 | 0.00 | -209.06 | -1061.11 |
| T S1 APARTMENT | 10-JAN-06:00 | -763.82 | 0.00 | 1795.43 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -335.58 | 0.00 | -209.06 | -991.48 |
| T S2 APARTMENT | 10-JAN-06:00 | -763.82 | 0.00 | 1796.25 | 0.00 | 0.00 | 0.00 | 194.99 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -335.57 | 0.00 | -209.06 | -992.32 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 28-DEC-08:61 | -18719.71 | 0.00 | 46172.10 | 0.00 | 0.00 | 0.00 | 2174.85 | 2872.71 | 12840.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12186.41 | 0.00 | -9836.33 | -23317.45 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3428 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3428 | 0.0757 | 1.0000 | Not calculated | 0.0260 | 0.0757 | ||
| SPLIT GNW | 0.2812 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2812 | 0.0923 | 1.0000 | Not calculated | 0.0260 | 0.0923 | ||
| SPLIT OFFICE | 0.3692 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3692 | 0.1032 | 1.0000 | Not calculated | 0.0381 | 0.1032 | ||
| SPLIT GNE | 0.2420 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2420 | 0.1072 | 1.0000 | Not calculated | 0.0260 | 0.1072 | ||
| SPLIT GN1 | 0.2279 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2279 | 0.1139 | 1.0000 | Not calculated | 0.0260 | 0.1139 | ||
| SPLIT GN2 | 0.2269 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2269 | 0.1144 | 1.0000 | Not calculated | 0.0260 | 0.1144 | ||
| SPLIT GS1 | 0.2908 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2908 | 0.0892 | 1.0000 | Not calculated | 0.0260 | 0.0892 | ||
| SPLIT GS2 | 0.2921 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2921 | 0.0889 | 1.0000 | Not calculated | 0.0260 | 0.0889 | ||
| SPLIT MSW | 0.8600 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8600 | 0.0604 | 1.0000 | Not calculated | 0.0519 | 0.0604 | ||
| SPLIT MNW | 0.7482 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7482 | 0.0694 | 1.0000 | Not calculated | 0.0519 | 0.0694 | ||
| SPLIT MSE | 0.7391 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7391 | 0.0702 | 1.0000 | Not calculated | 0.0519 | 0.0702 | ||
| SPLIT MNE | 0.6302 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6302 | 0.0824 | 1.0000 | Not calculated | 0.0519 | 0.0824 | ||
| SPLIT MN1 | 0.5779 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5779 | 0.0898 | 1.0000 | Not calculated | 0.0519 | 0.0898 | ||
| SPLIT MN2 | 0.5759 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5759 | 0.0901 | 1.0000 | Not calculated | 0.0519 | 0.0901 | ||
| SPLIT MS1 | 0.7008 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7008 | 0.0741 | 1.0000 | Not calculated | 0.0519 | 0.0741 | ||
| SPLIT MS2 | 0.6985 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6985 | 0.0743 | 1.0000 | Not calculated | 0.0519 | 0.0743 | ||
| SPLIT TSW | 0.4590 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4590 | 0.0565 | 1.0000 | Not calculated | 0.0260 | 0.0565 | ||
| SPLIT TNW | 0.4141 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4141 | 0.0627 | 1.0000 | Not calculated | 0.0260 | 0.0627 | ||
| SPLIT TSE | 0.3712 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3712 | 0.0699 | 1.0000 | Not calculated | 0.0260 | 0.0699 | ||
| SPLIT TNE | 0.3268 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3268 | 0.0794 | 1.0000 | Not calculated | 0.0260 | 0.0794 | ||
| SPLIT TN1 | 0.3168 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3168 | 0.0819 | 1.0000 | Not calculated | 0.0260 | 0.0819 | ||
| SPLIT TN2 | 0.3140 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3140 | 0.0827 | 1.0000 | Not calculated | 0.0260 | 0.0827 | ||
| SPLIT TS1 | 0.3646 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3646 | 0.0712 | 1.0000 | Not calculated | 0.0260 | 0.0712 | ||
| SPLIT TS2 | 0.3619 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3619 | 0.0717 | 1.0000 | Not calculated | 0.0260 | 0.0717 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3428 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3428 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0757 | ||
| SPLIT GNW | 0.2812 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2812 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0923 | ||
| SPLIT OFFICE | 0.3692 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3692 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.1032 | ||
| SPLIT GNE | 0.2420 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2420 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.1072 | ||
| SPLIT GN1 | 0.2279 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2279 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.1139 | ||
| SPLIT GN2 | 0.2269 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2269 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.1144 | ||
| SPLIT GS1 | 0.2908 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2908 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0892 | ||
| SPLIT GS2 | 0.2921 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2921 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0889 | ||
| SPLIT MSW | 0.8600 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8600 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0604 | ||
| SPLIT MNW | 0.7482 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7482 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0694 | ||
| SPLIT MSE | 0.7391 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7391 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0702 | ||
| SPLIT MNE | 0.6302 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6302 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0824 | ||
| SPLIT MN1 | 0.5779 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5779 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0898 | ||
| SPLIT MN2 | 0.5759 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5759 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0901 | ||
| SPLIT MS1 | 0.7008 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7008 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0741 | ||
| SPLIT MS2 | 0.6985 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6985 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0743 | ||
| SPLIT TSW | 0.4590 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4590 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0565 | ||
| SPLIT TNW | 0.4141 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4141 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0627 | ||
| SPLIT TSE | 0.3712 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3712 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0699 | ||
| SPLIT TNE | 0.3268 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3268 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0794 | ||
| SPLIT TN1 | 0.3168 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3168 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0819 | ||
| SPLIT TN2 | 0.3140 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3140 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0827 | ||
| SPLIT TS1 | 0.3646 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3646 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0712 | ||
| SPLIT TS2 | 0.3619 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3619 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0717 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3428 | 0.3428 | 0.3428 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2812 | 0.2812 | 0.2812 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3692 | 0.3692 | 0.3692 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2420 | 0.2420 | 0.2420 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2279 | 0.2279 | 0.2279 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2269 | 0.2269 | 0.2269 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2908 | 0.2908 | 0.2908 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2921 | 0.2921 | 0.2921 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8600 | 0.8600 | 0.8600 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7482 | 0.7482 | 0.7482 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7391 | 0.7391 | 0.7391 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6302 | 0.6302 | 0.6302 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5779 | 0.5779 | 0.5779 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5759 | 0.5759 | 0.5759 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7008 | 0.7008 | 0.7008 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6985 | 0.6985 | 0.6985 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4590 | 0.4590 | 0.4590 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4141 | 0.4141 | 0.4141 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3712 | 0.3712 | 0.3712 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3268 | 0.3268 | 0.3268 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3168 | 0.3168 | 0.3168 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3140 | 0.3140 | 0.3140 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3646 | 0.3646 | 0.3646 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3619 | 0.3619 | 0.3619 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3428 | 0.3428 | 0.3428 | 0.3428 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.2812 | 0.2812 | 0.2812 | 0.2812 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3692 | 0.3692 | 0.3692 | 0.3692 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.2420 | 0.2420 | 0.2420 | 0.2420 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2279 | 0.2279 | 0.2279 | 0.2279 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2269 | 0.2269 | 0.2269 | 0.2269 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2908 | 0.2908 | 0.2908 | 0.2908 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2921 | 0.2921 | 0.2921 | 0.2921 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.8600 | 0.8600 | 0.8600 | 0.8600 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.7482 | 0.7482 | 0.7482 | 0.7482 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7391 | 0.7391 | 0.7391 | 0.7391 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6302 | 0.6302 | 0.6302 | 0.6302 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.5779 | 0.5779 | 0.5779 | 0.5779 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.5759 | 0.5759 | 0.5759 | 0.5759 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7008 | 0.7008 | 0.7008 | 0.7008 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6985 | 0.6985 | 0.6985 | 0.6985 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4590 | 0.4590 | 0.4590 | 0.4590 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4141 | 0.4141 | 0.4141 | 0.4141 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3712 | 0.3712 | 0.3712 | 0.3712 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3268 | 0.3268 | 0.3268 | 0.3268 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3168 | 0.3168 | 0.3168 | 0.3168 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3140 | 0.3140 | 0.3140 | 0.3140 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3646 | 0.3646 | 0.3646 | 0.3646 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3619 | 0.3619 | 0.3619 | 0.3619 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3428 | 0.3428 | 0.3428 | No | 0.0260 | 0.3585 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2812 | 0.2812 | 0.2812 | No | 0.0260 | 0.3933 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3692 | 0.3692 | 0.3692 | No | 0.0381 | 0.3991 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2420 | 0.2420 | 0.2420 | No | 0.0260 | 0.3927 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2279 | 0.2279 | 0.2279 | No | 0.0260 | 0.6833 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2269 | 0.2269 | 0.2269 | No | 0.0260 | 0.6833 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2908 | 0.2908 | 0.2908 | No | 0.0260 | 0.5836 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2921 | 0.2921 | 0.2921 | No | 0.0260 | 0.5778 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8600 | 0.8600 | 0.8600 | No | 0.0519 | 0.4672 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7482 | 0.7482 | 0.7482 | No | 0.0519 | 0.5418 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7391 | 0.7391 | 0.7391 | No | 0.0519 | 0.4661 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6302 | 0.6302 | 0.6302 | No | 0.0519 | 0.5403 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5779 | 0.5779 | 0.5779 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5759 | 0.5759 | 0.5759 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7008 | 0.7008 | 0.7008 | No | 0.0519 | 0.9018 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6985 | 0.6985 | 0.6985 | No | 0.0519 | 0.9017 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4590 | 0.4590 | 0.4590 | No | 0.0260 | 0.2472 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4141 | 0.4141 | 0.4141 | No | 0.0260 | 0.2685 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3712 | 0.3712 | 0.3712 | No | 0.0260 | 0.2468 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3268 | 0.3268 | 0.3268 | No | 0.0260 | 0.2679 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3168 | 0.3168 | 0.3168 | No | 0.0260 | 0.3948 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3140 | 0.3140 | 0.3140 | No | 0.0260 | 0.3948 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3646 | 0.3646 | 0.3646 | No | 0.0260 | 0.3504 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3619 | 0.3619 | 0.3619 | No | 0.0260 | 0.3504 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3428 | 0.3428 | 0.3428 | 0.3428 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.2812 | 0.2812 | 0.2812 | 0.2812 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3692 | 0.3692 | 0.3692 | 0.3692 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.2420 | 0.2420 | 0.2420 | 0.2420 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2279 | 0.2279 | 0.2279 | 0.2279 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2269 | 0.2269 | 0.2269 | 0.2269 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2908 | 0.2908 | 0.2908 | 0.2908 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2921 | 0.2921 | 0.2921 | 0.2921 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.8600 | 0.8600 | 0.8600 | 0.8600 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.7482 | 0.7482 | 0.7482 | 0.7482 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7391 | 0.7391 | 0.7391 | 0.7391 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6302 | 0.6302 | 0.6302 | 0.6302 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.5779 | 0.5779 | 0.5779 | 0.5779 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.5759 | 0.5759 | 0.5759 | 0.5759 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.7008 | 0.7008 | 0.7008 | 0.7008 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6985 | 0.6985 | 0.6985 | 0.6985 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4590 | 0.4590 | 0.4590 | 0.4590 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4141 | 0.4141 | 0.4141 | 0.4141 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3712 | 0.3712 | 0.3712 | 0.3712 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3268 | 0.3268 | 0.3268 | 0.3268 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3168 | 0.3168 | 0.3168 | 0.3168 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3140 | 0.3140 | 0.3140 | 0.3140 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3646 | 0.3646 | 0.3646 | 0.3646 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3619 | 0.3619 | 0.3619 | 0.3619 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Natural Gas |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 270.62 | 54764.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 33.10 | 17957.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 94.96 | 5496.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 4.27 | 407.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 49.92 | 3183.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 388.06 | 18541.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 65.48 | 4006.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 5.11 | 162.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 71.54 | 6881.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 478.47 | 37826.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 458.66 | 1190.91 |
| Natural Gas | 0.00 | 270.62 |
| Additional | 0.00 | 0.00 |
| Total | 458.66 | 1461.53 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 31.66 |
| Space Heating | 0.00 |
| Space Cooling | 10.56 |
| Fans (All) | 22.82 |
| Service Water Heating | 152.64 |
| Receptacle Equipment | 146.32 |
| Miscellaneous (All) | 379.92 |
| Subtotal | 379.92 |
| Natural Gas [MJ/m2] | |
| Space Heating | 86.33 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 86.33 |
| Subtotal | 86.33 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 6.79 |
| Space Heating | 18.52 |
| Space Cooling | 2.26 |
| Fans (All) | 4.89 |
| Service Water Heating | 32.74 |
| Receptacle Equipment | 31.38 |
| Miscellaneous | 3.42 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 8760. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 4531. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| BLDG_ELEVATORS | 2270. | 8760. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_YES_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 8679.67 | 80.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 8424.17 | 335.83 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 8758.67 | 1.33 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 6904.00 | 1856.00 | 0.00 | 0.00 | 0.00 |
| Min | 6904.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 1856.00 | 0.00 | 0.00 | 0.00 |
| Average | 8675.80 | 84.20 | 0.00 | 0.00 | 0.00 |
| Sum | 234246.50 | 2273.50 | 0.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 22191.67 | 803.33 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 22992.17 | 2.83 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 18342.83 | 4652.17 | 0.00 | 0.00 | 0.00 |
| Min | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 22992.17 | 4652.17 | 0.00 | 0.00 | 0.00 |
| Average | 12136.17 | 202.16 | 0.00 | 0.00 | 0.00 |
| Sum | 327676.67 | 5458.33 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 8674.83 | 85.17 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 2914.00 | 5845.00 | 1.00 | 0.00 | 0.00 |
| G CORRIDOR | 8326.83 | 433.17 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 63.83 | 8687.67 | 8.50 | 0.00 | 0.00 |
| Min | 63.83 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 8687.67 | 8.50 | 0.00 | 0.00 |
| Average | 8202.20 | 557.44 | 0.35 | 0.00 | 0.00 |
| Sum | 221459.50 | 15051.00 | 9.50 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6996.67 | 3.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 7416.50 | 15574.50 | 4.00 | 0.00 | 0.00 |
| G CORRIDOR | 21267.50 | 1727.50 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 176.33 | 22790.17 | 28.50 | 0.00 | 0.00 |
| Min | 176.33 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 21267.50 | 22790.17 | 28.50 | 0.00 | 0.00 |
| Average | 10852.11 | 1485.02 | 1.20 | 0.00 | 0.00 |
| Sum | 293007.00 | 40095.50 | 32.50 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:15:07
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 4.180 |
| February | 4.245 |
| March | 5.898 |
| April | 8.962 |
| May | 9.987 |
| June | 13.308 |
| July | 15.016 |
| August | 15.650 |
| September | 13.434 |
| October | 9.327 |
| November | 6.665 |
| December | 4.103 |
| Annual Sum or Average | 9.257 |
| Minimum of Months | 4.103 |
| Maximum of Months | 15.650 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.130330E+09 | 516.61 | 21-JAN-17:01 | 4.00 | 3.53 | 78235000.27 | 45.39 | 15-JAN-16:10 | 4.00 | 3.53 |
| February | 0.160752E+09 | 535.87 | 19-FEB-17:45 | 3.50 | 2.91 | 69747681.87 | 49.31 | 04-FEB-16:10 | 3.50 | 2.91 |
| March | 83276859.05 | 392.56 | 23-MAR-18:00 | 8.00 | 6.08 | 74999914.26 | 45.21 | 23-MAR-17:10 | 8.00 | 6.08 |
| April | 0.710985E+09 | 1340.18 | 30-APR-16:10 | 24.00 | 13.04 | 84938619.83 | 70.35 | 22-APR-17:10 | 24.00 | 13.04 |
| May | 0.807309E+09 | 726.38 | 25-MAY-16:40 | 15.33 | 12.87 | 89749578.86 | 70.35 | 25-MAY-19:49 | 11.17 | 9.94 |
| June | 0.990438E+09 | 1459.64 | 13-JUN-17:20 | 25.97 | 17.22 | 0.104745E+09 | 70.35 | 16-JUN-19:30 | 13.50 | 11.52 |
| July | 0.131923E+10 | 1870.49 | 22-JUL-16:30 | 29.00 | 16.57 | 0.120767E+09 | 70.36 | 31-JUL-22:10 | 11.13 | 9.99 |
| August | 0.136737E+10 | 1693.80 | 14-AUG-16:14 | 26.33 | 15.41 | 0.120622E+09 | 70.35 | 24-AUG-22:40 | 14.67 | 10.56 |
| September | 0.133856E+10 | 1656.88 | 13-SEP-16:05 | 23.00 | 16.14 | 0.116097E+09 | 70.36 | 26-SEP-01:19 | 12.33 | 9.47 |
| October | 0.744735E+09 | 984.80 | 03-OCT-16:04 | 13.83 | 8.88 | 89377260.18 | 70.37 | 07-OCT-18:40 | 9.67 | 7.47 |
| November | 0.235785E+09 | 552.91 | 11-NOV-17:55 | 3.00 | 2.55 | 75224425.44 | 53.25 | 05-NOV-15:50 | 3.00 | 2.55 |
| December | 36532233.47 | 452.49 | 26-DEC-14:40 | 6.00 | 3.11 | 78198344.13 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.792529E+10 | 0.110270E+10 | ||||||||
| Minimum of Months | 36532233.47 | 392.56 | 3.00 | 2.55 | 69747681.87 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.136737E+10 | 1870.49 | 29.00 | 17.22 | 0.120767E+09 | 70.37 | 24.00 | 13.04 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 2098531.64 | 136.64 | 19-JAN-16:10 | 7.67 | 7.22 | 77895344.66 | 42.51 | 11-JAN-06:49 | 7.67 | 7.22 |
| February | 2572915.87 | 227.23 | 27-FEB-17:02 | 7.83 | 6.89 | 70357085.50 | 42.51 | 04-FEB-22:00 | 7.83 | 6.89 |
| March | 19437805.40 | 338.11 | 20-MAR-16:20 | 9.67 | 6.04 | 77881768.08 | 42.51 | 18-MAR-05:30 | 9.67 | 6.04 |
| April | 0.334084E+09 | 481.27 | 30-APR-17:40 | 24.00 | 12.95 | 78549826.00 | 68.31 | 30-APR-20:10 | 16.67 | 12.21 |
| May | 0.559597E+09 | 519.25 | 01-MAY-05:00 | 4.00 | 3.53 | 84832089.21 | 66.45 | 23-MAY-20:10 | 13.67 | 10.55 |
| June | 0.815305E+09 | 1096.64 | 13-JUN-18:00 | 23.90 | 16.48 | 0.102417E+09 | 70.36 | 25-JUN-22:30 | 15.50 | 12.91 |
| July | 0.979761E+09 | 1495.59 | 22-JUL-18:30 | 29.50 | 16.91 | 0.117293E+09 | 70.35 | 24-JUL-00:20 | 13.00 | 13.00 |
| August | 0.801436E+09 | 1052.59 | 14-AUG-17:05 | 27.00 | 14.28 | 0.119690E+09 | 70.36 | 19-AUG-21:10 | 12.17 | 10.98 |
| September | 0.743214E+09 | 735.80 | 13-SEP-16:30 | 23.00 | 15.99 | 0.101377E+09 | 70.27 | 13-SEP-20:10 | 14.50 | 12.28 |
| October | 0.376017E+09 | 491.19 | 05-OCT-20:00 | 5.00 | 4.09 | 79736882.22 | 51.28 | 03-OCT-17:10 | 5.00 | 4.09 |
| November | 38758765.65 | 377.98 | 10-NOV-16:40 | 8.33 | 7.19 | 75372312.89 | 42.51 | 29-NOV-06:49 | -1.0 | -1.5 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 77895344.65 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.467228E+10 | 0.106330E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 4.00 | 3.53 | 70357085.50 | 42.51 | -1.0 | -1.5 | ||
| Maximum of Months | 0.979761E+09 | 1495.59 | 29.50 | 16.91 | 0.119690E+09 | 70.36 | 16.67 | 13.00 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.527210E+09 | 980.93 | 10-JAN-08:03 | -5.7 | -6.7 | 39396776.38 | 97.65 | 20-JAN-15:39 | 7.33 | 6.17 |
| February | 0.516725E+09 | 834.52 | 17-FEB-08:03 | -2.3 | -2.4 | 37160066.25 | 90.95 | 09-FEB-15:00 | -2.3 | -2.4 |
| March | 0.406479E+09 | 666.66 | 13-MAR-07:03 | 1.33 | 0.37 | 44997391.34 | 89.10 | 30-MAR-15:20 | 12.00 | 6.31 |
| April | 0.579180E+09 | 1177.46 | 28-APR-14:40 | 20.07 | 13.39 | 55540344.01 | 142.24 | 28-APR-08:09 | 20.07 | 13.39 |
| May | 0.625997E+09 | 2615.72 | 23-MAY-08:63 | 17.33 | 14.10 | 65903104.57 | 151.21 | 23-MAY-08:09 | 17.33 | 14.10 |
| June | 0.749659E+09 | 5457.80 | 21-JUN-08:62 | 17.33 | 14.02 | 74185301.13 | 171.08 | 26-JUN-07:10 | 19.67 | 14.49 |
| July | 0.979666E+09 | 5398.84 | 12-JUL-08:62 | 13.50 | 12.10 | 69172937.72 | 181.30 | 24-JUL-07:10 | 14.00 | 13.43 |
| August | 0.121088E+10 | 5525.91 | 29-AUG-08:62 | 13.50 | 12.10 | 80032145.43 | 167.27 | 15-AUG-07:10 | 13.50 | 12.10 |
| September | 0.114798E+10 | 5598.24 | 26-SEP-08:62 | 12.50 | 10.03 | 68511556.27 | 166.81 | 13-SEP-08:09 | 12.50 | 10.03 |
| October | 0.618341E+09 | 1305.80 | 03-OCT-14:30 | 14.00 | 9.18 | 57646646.92 | 138.50 | 02-OCT-08:09 | 14.00 | 9.18 |
| November | 0.459345E+09 | 754.52 | 29-NOV-08:03 | -0.7 | -1.6 | 41417359.82 | 114.91 | 10-NOV-15:30 | -0.7 | -1.6 |
| December | 0.493635E+09 | 770.65 | 27-DEC-08:03 | -1.0 | -1.4 | 38898483.72 | 83.76 | 21-DEC-15:09 | -1.0 | -1.4 |
| Annual Sum or Average | 0.831509E+10 | 0.672862E+09 | ||||||||
| Minimum of Months | 0.406479E+09 | 666.66 | -5.7 | -6.7 | 37160066.25 | 83.76 | -2.3 | -2.4 | ||
| Maximum of Months | 0.121088E+10 | 5598.24 | 20.07 | 14.10 | 80032145.43 | 181.30 | 20.07 | 14.49 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 130384.34 | 33.25 | 29-JAN-17:02 | 9.88 | 9.33 | 77895344.66 | 42.51 | 11-JAN-06:49 | 9.88 | 9.33 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 | 5.79 | 70357085.50 | 42.51 | 04-FEB-22:00 | 5.00 | 4.51 |
| March | 12853631.69 | 337.82 | 20-MAR-16:20 | 9.67 | 6.04 | 77882417.73 | 42.51 | 10-MAR-22:30 | 9.67 | 6.04 |
| April | 0.381725E+09 | 427.81 | 29-APR-05:50 | 6.83 | 6.31 | 78456910.00 | 66.75 | 30-APR-20:10 | 16.67 | 12.21 |
| May | 0.583788E+09 | 519.71 | 01-MAY-05:00 | 4.00 | 3.53 | 83911958.90 | 62.39 | 23-MAY-20:10 | 13.67 | 10.55 |
| June | 0.792741E+09 | 721.99 | 25-JUN-16:10 | 24.33 | 14.70 | 0.100851E+09 | 70.35 | 24-JUN-20:30 | 24.33 | 14.70 |
| July | 0.927741E+09 | 1153.54 | 22-JUL-18:30 | 29.50 | 16.91 | 0.117521E+09 | 70.36 | 27-JUL-20:00 | 13.00 | 11.88 |
| August | 0.813297E+09 | 786.35 | 14-AUG-17:30 | 27.00 | 14.07 | 0.120307E+09 | 70.36 | 24-AUG-20:30 | 14.50 | 10.49 |
| September | 0.756197E+09 | 563.65 | 13-SEP-16:20 | 23.00 | 16.07 | 0.103142E+09 | 70.27 | 13-SEP-20:10 | 14.50 | 12.28 |
| October | 0.387563E+09 | 488.12 | 05-OCT-20:00 | 5.00 | 4.09 | 79655927.85 | 50.16 | 01-OCT-20:10 | 5.00 | 4.09 |
| November | 29252037.47 | 377.71 | 10-NOV-16:40 | 8.33 | 7.19 | 75371499.72 | 42.51 | 29-NOV-06:49 | -1.0 | -1.5 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 77895344.65 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.468529E+10 | 0.106325E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 4.00 | 3.53 | 70357085.50 | 42.51 | -1.0 | -1.5 | ||
| Maximum of Months | 0.927741E+09 | 1153.54 | 29.50 | 16.91 | 0.120307E+09 | 70.36 | 24.33 | 14.70 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 54944745.64 | 222.79 | 29-JAN-17:02 | 9.88 | 9.33 | 77895344.66 | 42.51 | 11-JAN-06:49 | 9.88 | 9.33 |
| February | 25393871.16 | 164.06 | 27-FEB-17:02 | 7.83 | 6.89 | 70357085.50 | 42.51 | 18-FEB-06:49 | 7.83 | 6.89 |
| March | 0.116114E+09 | 338.16 | 20-MAR-16:20 | 9.67 | 6.04 | 77890489.64 | 42.51 | 18-MAR-21:30 | 9.67 | 6.04 |
| April | 0.476176E+09 | 441.41 | 25-APR-21:00 | 6.40 | 5.73 | 78160005.70 | 64.10 | 30-APR-20:10 | 16.67 | 12.21 |
| May | 0.715737E+09 | 527.13 | 01-MAY-05:00 | 4.00 | 3.53 | 84666162.33 | 61.42 | 23-MAY-20:10 | 13.67 | 10.55 |
| June | 0.792812E+09 | 582.12 | 13-JUN-18:00 | 23.90 | 16.48 | 0.105015E+09 | 70.34 | 13-JUN-20:10 | 16.50 | 13.79 |
| July | 0.883023E+09 | 959.14 | 22-JUL-18:40 | 29.33 | 16.94 | 0.120852E+09 | 70.36 | 09-JUL-22:10 | 29.33 | 16.94 |
| August | 0.762150E+09 | 673.31 | 14-AUG-18:00 | 27.00 | 13.76 | 0.123141E+09 | 70.36 | 03-AUG-20:40 | 27.00 | 13.76 |
| September | 0.751434E+09 | 514.57 | 20-SEP-24:00 | 5.00 | 4.51 | 0.106792E+09 | 70.33 | 15-SEP-20:00 | 5.00 | 4.51 |
| October | 0.632761E+09 | 542.91 | 04-OCT-01:50 | 3.17 | 3.09 | 81303981.91 | 54.14 | 01-OCT-20:10 | 3.17 | 3.09 |
| November | 0.211331E+09 | 379.03 | 10-NOV-16:40 | 8.33 | 7.19 | 75388345.59 | 42.83 | 08-NOV-21:10 | 8.33 | 7.19 |
| December | 12443096.82 | 132.32 | 05-DEC-19:00 | 6.00 | 5.48 | 77895344.66 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.543432E+10 | 0.107936E+10 | ||||||||
| Minimum of Months | 12443096.82 | 132.32 | 3.17 | 3.09 | 70357085.50 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.883023E+09 | 959.14 | 29.33 | 16.94 | 0.123141E+09 | 70.36 | 29.33 | 16.94 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 54689202.09 | 222.28 | 29-JAN-17:02 | 9.88 | 9.33 | 77895344.66 | 42.51 | 11-JAN-06:49 | 9.88 | 9.33 |
| February | 24880642.32 | 161.83 | 07-FEB-17:02 | 8.83 | 8.36 | 70357085.50 | 42.51 | 18-FEB-06:49 | -1.8 | -1.9 |
| March | 0.116123E+09 | 338.16 | 20-MAR-16:20 | 9.67 | 6.04 | 77890509.91 | 42.51 | 18-MAR-21:30 | 9.67 | 6.04 |
| April | 0.480402E+09 | 448.86 | 25-APR-21:03 | 6.17 | 5.53 | 78206260.02 | 64.21 | 30-APR-20:10 | 16.67 | 12.21 |
| May | 0.718194E+09 | 527.56 | 01-MAY-05:00 | 4.00 | 3.53 | 84641790.62 | 61.28 | 23-MAY-20:10 | 13.67 | 10.55 |
| June | 0.792020E+09 | 581.47 | 25-JUN-18:00 | 22.00 | 19.93 | 0.104850E+09 | 70.28 | 13-JUN-20:10 | 22.00 | 19.93 |
| July | 0.882329E+09 | 951.81 | 22-JUL-18:40 | 29.33 | 16.94 | 0.120983E+09 | 70.37 | 09-JUL-22:10 | 29.33 | 16.94 |
| August | 0.765762E+09 | 670.20 | 14-AUG-18:00 | 27.00 | 13.76 | 0.123250E+09 | 70.37 | 06-AUG-21:49 | 27.00 | 13.76 |
| September | 0.755174E+09 | 515.46 | 20-SEP-24:00 | 5.00 | 4.51 | 0.107202E+09 | 70.36 | 15-SEP-20:00 | 5.00 | 4.51 |
| October | 0.633863E+09 | 542.90 | 04-OCT-01:50 | 3.17 | 3.09 | 81322383.24 | 54.10 | 01-OCT-20:10 | 3.17 | 3.09 |
| November | 0.211244E+09 | 379.00 | 10-NOV-16:40 | 8.33 | 7.19 | 75388202.18 | 42.82 | 08-NOV-21:10 | 8.33 | 7.19 |
| December | 12638933.21 | 131.89 | 05-DEC-19:00 | 6.00 | 5.48 | 77895344.66 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.544732E+10 | 0.107988E+10 | ||||||||
| Minimum of Months | 12638933.21 | 131.89 | 3.17 | 3.09 | 70357085.50 | 42.51 | -1.8 | -1.9 | ||
| Maximum of Months | 0.882329E+09 | 951.81 | 29.33 | 19.93 | 0.123250E+09 | 70.37 | 29.33 | 19.93 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.398899E+09 | 634.90 | 11-JAN-14:00 | -2.0 | -3.5 | 78391739.73 | 47.98 | 21-JAN-16:10 | 5.75 | 4.88 |
| February | 0.381761E+09 | 579.50 | 19-FEB-18:25 | 2.00 | 1.78 | 69885672.83 | 51.41 | 04-FEB-16:10 | 2.00 | 1.78 |
| March | 0.290897E+09 | 432.05 | 12-MAR-16:17 | 6.67 | 4.14 | 75070804.36 | 45.93 | 25-MAR-16:49 | 11.00 | 9.78 |
| April | 0.897212E+09 | 1007.24 | 30-APR-16:10 | 24.00 | 13.04 | 87629063.58 | 70.31 | 29-APR-21:19 | 24.00 | 13.04 |
| May | 0.934894E+09 | 577.03 | 03-MAY-05:00 | 3.00 | 2.55 | 93340940.56 | 70.36 | 22-MAY-18:30 | 19.00 | 14.26 |
| June | 0.968214E+09 | 939.00 | 13-JUN-16:05 | 26.58 | 17.67 | 0.108880E+09 | 70.37 | 19-JUN-19:00 | 11.00 | 9.86 |
| July | 0.124654E+10 | 1384.76 | 22-JUL-16:10 | 29.00 | 16.57 | 0.124651E+09 | 70.36 | 14-JUL-21:49 | 29.00 | 16.57 |
| August | 0.140407E+10 | 1310.49 | 20-AUG-16:05 | 23.67 | 14.78 | 0.122966E+09 | 70.37 | 22-AUG-23:40 | 12.00 | 8.74 |
| September | 0.146450E+10 | 1354.34 | 25-SEP-15:10 | 22.00 | 13.57 | 0.120640E+09 | 70.36 | 29-SEP-23:00 | 11.00 | 7.52 |
| October | 0.102268E+10 | 955.24 | 01-OCT-14:10 | 13.00 | 9.37 | 95373885.09 | 70.36 | 02-OCT-20:19 | 8.67 | 7.29 |
| November | 0.599985E+09 | 583.55 | 11-NOV-21:00 | 2.00 | 2.00 | 75763992.15 | 55.11 | 05-NOV-15:50 | 2.00 | 2.00 |
| December | 0.187901E+09 | 501.02 | 26-DEC-15:30 | 4.50 | 2.61 | 78201210.61 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.979755E+10 | 0.113079E+10 | ||||||||
| Minimum of Months | 0.187901E+09 | 432.05 | -2.0 | -3.5 | 69885672.83 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.146450E+10 | 1384.76 | 29.00 | 17.67 | 0.124651E+09 | 70.37 | 29.00 | 16.57 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.318275E+09 | 584.36 | 11-JAN-14:00 | -2.0 | -3.5 | 78322781.67 | 47.22 | 21-JAN-16:10 | 5.75 | 4.88 |
| February | 0.313923E+09 | 534.66 | 19-FEB-17:45 | 3.50 | 2.91 | 69791914.55 | 50.45 | 04-FEB-16:10 | 3.50 | 2.91 |
| March | 0.239275E+09 | 400.14 | 10-MAR-16:20 | 7.67 | 3.99 | 75046600.46 | 45.32 | 25-MAR-16:49 | 11.00 | 9.78 |
| April | 0.895937E+09 | 1070.21 | 30-APR-16:10 | 24.00 | 13.04 | 88045081.37 | 70.36 | 28-APR-17:40 | 24.00 | 13.04 |
| May | 0.950367E+09 | 579.79 | 03-MAY-05:00 | 3.00 | 2.55 | 94027710.34 | 70.35 | 25-MAY-18:00 | 12.00 | 10.35 |
| June | 0.996673E+09 | 981.38 | 26-JUN-15:10 | 22.83 | 17.31 | 0.109571E+09 | 70.36 | 26-JUN-02:20 | 22.83 | 17.31 |
| July | 0.131408E+10 | 1468.64 | 22-JUL-16:10 | 29.00 | 16.57 | 0.125233E+09 | 70.36 | 13-JUL-03:00 | 29.00 | 16.57 |
| August | 0.149275E+10 | 1384.92 | 20-AUG-16:10 | 23.67 | 14.78 | 0.123251E+09 | 70.36 | 23-AUG-23:30 | 12.50 | 9.56 |
| September | 0.153039E+10 | 1400.04 | 25-SEP-15:10 | 22.00 | 13.57 | 0.121014E+09 | 70.36 | 25-SEP-03:00 | 22.00 | 13.57 |
| October | 0.103231E+10 | 984.45 | 01-OCT-14:10 | 13.00 | 9.37 | 95716538.22 | 70.37 | 04-OCT-19:40 | 6.67 | 6.00 |
| November | 0.552174E+09 | 582.39 | 11-NOV-21:00 | 2.00 | 2.00 | 75663050.65 | 54.36 | 05-NOV-15:39 | 2.00 | 2.00 |
| December | 0.139667E+09 | 484.24 | 26-DEC-15:20 | 5.00 | 2.88 | 78198669.38 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.977583E+10 | 0.113388E+10 | ||||||||
| Minimum of Months | 0.139667E+09 | 400.14 | -2.0 | -3.5 | 69791914.55 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.153039E+10 | 1468.64 | 29.00 | 17.31 | 0.125233E+09 | 70.37 | 29.00 | 17.31 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.585646E+09 | 736.89 | 11-JAN-17:01 | -3.2 | -4.7 | 79951452.59 | 60.18 | 21-JAN-16:10 | 5.75 | 4.88 |
| February | 0.632971E+09 | 734.58 | 17-FEB-21:00 | -3.0 | -3.0 | 71910338.82 | 65.65 | 04-FEB-16:10 | -3.0 | -3.0 |
| March | 0.651990E+09 | 559.74 | 10-MAR-21:00 | 3.00 | 3.00 | 76904085.42 | 59.49 | 20-MAR-17:10 | 8.83 | 5.63 |
| April | 0.158265E+10 | 2558.77 | 30-APR-16:10 | 24.00 | 13.04 | 0.106135E+09 | 70.32 | 20-APR-22:00 | 24.00 | 13.04 |
| May | 0.153303E+10 | 2035.37 | 22-MAY-16:10 | 22.33 | 15.17 | 0.111147E+09 | 70.30 | 26-MAY-22:40 | 10.33 | 8.89 |
| June | 0.183542E+10 | 2422.84 | 13-JUN-17:10 | 26.48 | 17.38 | 0.117324E+09 | 70.31 | 28-JUN-21:49 | 12.00 | 12.00 |
| July | 0.213540E+10 | 2556.38 | 22-JUL-16:20 | 29.00 | 16.57 | 0.127217E+09 | 70.32 | 03-JUL-21:10 | 29.00 | 16.57 |
| August | 0.216804E+10 | 2463.30 | 14-AUG-16:10 | 26.17 | 15.64 | 0.123389E+09 | 70.31 | 01-AUG-01:00 | 26.17 | 15.64 |
| September | 0.201336E+10 | 2316.26 | 12-SEP-15:30 | 21.50 | 15.72 | 0.120374E+09 | 70.31 | 12-SEP-03:30 | 21.50 | 15.72 |
| October | 0.118317E+10 | 1687.49 | 03-OCT-15:30 | 14.00 | 8.96 | 97828378.33 | 70.28 | 02-OCT-20:49 | 14.00 | 8.96 |
| November | 0.609150E+09 | 605.72 | 11-NOV-21:00 | 2.00 | 2.00 | 77109571.29 | 63.09 | 05-NOV-15:39 | 2.00 | 2.00 |
| December | 0.207144E+09 | 597.49 | 18-DEC-19:00 | 0.00 | -0.5 | 78254566.41 | 43.16 | 21-DEC-18:10 | 2.83 | 2.83 |
| Annual Sum or Average | 0.151380E+11 | 0.118754E+10 | ||||||||
| Minimum of Months | 0.207144E+09 | 559.74 | -3.2 | -4.7 | 71910338.82 | 43.16 | -3.0 | -3.0 | ||
| Maximum of Months | 0.216804E+10 | 2558.77 | 29.00 | 17.38 | 0.127217E+09 | 70.32 | 29.00 | 16.57 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.176152E+09 | 475.90 | 19-JAN-17:35 | 5.33 | 5.00 | 77904899.35 | 42.51 | 11-JAN-06:49 | 5.33 | 5.00 |
| February | 0.193370E+09 | 517.41 | 24-FEB-17:25 | 4.00 | 3.36 | 70387622.89 | 42.51 | 18-FEB-06:49 | 4.00 | 3.36 |
| March | 0.424539E+09 | 501.14 | 23-MAR-21:25 | 4.50 | 4.02 | 78477285.34 | 47.27 | 25-MAR-20:10 | 9.83 | 8.82 |
| April | 0.106306E+10 | 1717.92 | 30-APR-17:30 | 24.00 | 12.86 | 94233179.81 | 70.30 | 21-APR-20:10 | 24.00 | 12.86 |
| May | 0.119918E+10 | 1434.55 | 22-MAY-16:10 | 22.33 | 15.17 | 0.107334E+09 | 70.29 | 23-MAY-22:00 | 11.00 | 9.41 |
| June | 0.150918E+10 | 2160.76 | 13-JUN-17:30 | 25.45 | 17.05 | 0.120595E+09 | 70.30 | 22-JUN-23:30 | 11.00 | 10.48 |
| July | 0.167020E+10 | 2147.72 | 22-JUL-18:30 | 29.50 | 16.91 | 0.126321E+09 | 70.31 | 28-JUL-05:40 | 13.33 | 12.58 |
| August | 0.141486E+10 | 1790.67 | 14-AUG-17:05 | 27.00 | 14.28 | 0.127119E+09 | 70.31 | 04-AUG-23:49 | 27.00 | 14.28 |
| September | 0.106557E+10 | 1465.63 | 13-SEP-16:30 | 23.00 | 15.99 | 0.116066E+09 | 70.31 | 02-SEP-00:20 | 23.00 | 15.99 |
| October | 0.738604E+09 | 578.78 | 07-OCT-04:00 | 2.00 | 2.00 | 86844070.98 | 62.04 | 01-OCT-20:10 | 2.00 | 2.00 |
| November | 0.243406E+09 | 462.33 | 10-NOV-19:00 | 5.00 | 4.51 | 75499414.68 | 45.84 | 08-NOV-21:10 | 5.00 | 4.51 |
| December | 21297106.94 | 217.58 | 21-DEC-17:02 | 5.50 | 5.09 | 77895344.65 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.971941E+10 | 0.115868E+10 | ||||||||
| Minimum of Months | 21297106.94 | 217.58 | 2.00 | 2.00 | 70387622.89 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.167020E+10 | 2160.76 | 29.50 | 17.05 | 0.127119E+09 | 70.31 | 27.00 | 15.99 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.591039E+09 | 723.88 | 11-JAN-14:00 | -2.0 | -3.5 | 79977311.62 | 58.39 | 21-JAN-16:10 | 5.75 | 4.88 |
| February | 0.614058E+09 | 693.36 | 17-FEB-20:20 | -1.7 | -1.9 | 71459432.79 | 62.27 | 04-FEB-16:10 | -1.7 | -1.9 |
| March | 0.654241E+09 | 557.51 | 10-MAR-21:00 | 3.00 | 3.00 | 76840715.86 | 57.00 | 25-MAR-16:19 | 11.00 | 9.56 |
| April | 0.163302E+10 | 2213.62 | 30-APR-13:50 | 22.83 | 12.83 | 0.107036E+09 | 70.31 | 12-APR-17:00 | 22.83 | 12.83 |
| May | 0.153535E+10 | 1704.58 | 22-MAY-14:10 | 23.17 | 15.81 | 0.111514E+09 | 70.31 | 31-MAY-21:00 | 11.10 | 10.04 |
| June | 0.181084E+10 | 1952.63 | 13-JUN-13:30 | 24.55 | 17.26 | 0.116862E+09 | 70.31 | 10-JUN-22:10 | 24.55 | 17.26 |
| July | 0.210772E+10 | 2281.51 | 22-JUL-13:30 | 28.00 | 16.51 | 0.127277E+09 | 70.31 | 30-JUL-22:49 | 10.33 | 8.56 |
| August | 0.223631E+10 | 2096.75 | 14-AUG-14:10 | 24.17 | 16.49 | 0.123297E+09 | 70.31 | 23-AUG-23:40 | 12.33 | 9.47 |
| September | 0.210586E+10 | 2066.14 | 25-SEP-13:10 | 21.83 | 13.18 | 0.120609E+09 | 70.31 | 12-SEP-05:00 | 21.83 | 13.18 |
| October | 0.120222E+10 | 1452.29 | 03-OCT-13:40 | 13.67 | 9.38 | 97963430.09 | 70.31 | 11-OCT-19:00 | 8.00 | 7.45 |
| November | 0.611388E+09 | 604.12 | 11-NOV-21:00 | 2.00 | 2.00 | 77043104.05 | 60.77 | 05-NOV-15:39 | 2.00 | 2.00 |
| December | 0.228499E+09 | 591.07 | 18-DEC-19:00 | 0.00 | -0.5 | 78264205.40 | 43.65 | 03-DEC-10:00 | 0.00 | -0.5 |
| Annual Sum or Average | 0.153306E+11 | 0.118814E+10 | ||||||||
| Minimum of Months | 0.228499E+09 | 557.51 | -2.0 | -3.5 | 71459432.79 | 43.65 | -1.7 | -1.9 | ||
| Maximum of Months | 0.223631E+10 | 2281.51 | 28.00 | 17.26 | 0.127277E+09 | 70.31 | 24.55 | 17.26 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.173236E+09 | 369.77 | 19-JAN-17:08 | 5.83 | 5.75 | 77895846.86 | 42.51 | 11-JAN-06:49 | 5.83 | 5.75 |
| February | 0.166527E+09 | 392.90 | 22-FEB-18:00 | 7.00 | 5.54 | 70357770.28 | 42.51 | 18-FEB-06:49 | 7.00 | 5.54 |
| March | 0.433056E+09 | 463.27 | 12-MAR-17:15 | 5.67 | 3.58 | 78320016.23 | 48.60 | 25-MAR-20:10 | 9.83 | 8.82 |
| April | 0.109533E+10 | 1192.28 | 30-APR-17:20 | 24.00 | 12.77 | 95412487.73 | 70.31 | 27-APR-21:10 | 24.00 | 12.77 |
| May | 0.118621E+10 | 1126.11 | 23-MAY-10:10 | 20.00 | 14.59 | 0.107763E+09 | 70.29 | 11-MAY-20:40 | 20.00 | 14.59 |
| June | 0.148434E+10 | 1507.34 | 13-JUN-17:30 | 25.45 | 17.05 | 0.120100E+09 | 70.31 | 14-JUN-00:49 | 12.00 | 12.00 |
| July | 0.164201E+10 | 1617.58 | 22-JUL-18:30 | 29.50 | 16.91 | 0.126249E+09 | 70.31 | 26-JUL-00:30 | 13.00 | 13.00 |
| August | 0.147855E+10 | 1306.73 | 14-AUG-17:30 | 27.00 | 14.07 | 0.126985E+09 | 70.31 | 09-AUG-21:10 | 27.00 | 14.07 |
| September | 0.111432E+10 | 1046.17 | 13-SEP-16:20 | 23.00 | 16.07 | 0.117072E+09 | 70.31 | 04-SEP-21:49 | 23.00 | 16.07 |
| October | 0.753287E+09 | 579.03 | 07-OCT-04:00 | 2.00 | 2.00 | 86908468.73 | 61.47 | 01-OCT-20:10 | 2.00 | 2.00 |
| November | 0.239351E+09 | 428.19 | 10-NOV-17:08 | 6.83 | 6.31 | 75466624.42 | 45.59 | 08-NOV-21:10 | 6.83 | 6.31 |
| December | 26626714.55 | 206.44 | 20-DEC-20:00 | 6.00 | 6.00 | 77895344.66 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.979285E+10 | 0.116042E+10 | ||||||||
| Minimum of Months | 26626714.55 | 206.44 | 2.00 | 2.00 | 70357770.28 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.164201E+10 | 1617.58 | 29.50 | 17.05 | 0.126985E+09 | 70.31 | 27.00 | 16.07 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.534131E+09 | 528.28 | 19-JAN-18:35 | 3.67 | 2.94 | 78098399.24 | 44.93 | 29-JAN-21:10 | 8.00 | 7.45 |
| February | 0.505089E+09 | 487.69 | 27-FEB-19:00 | 5.00 | 5.00 | 70417909.14 | 44.36 | 07-FEB-21:10 | 5.00 | 5.00 |
| March | 0.825299E+09 | 540.89 | 21-MAR-21:50 | 3.23 | 2.35 | 79334325.58 | 50.27 | 25-MAR-20:10 | 9.83 | 8.82 |
| April | 0.108773E+10 | 984.87 | 30-APR-18:50 | 24.00 | 13.14 | 97104842.99 | 70.27 | 30-APR-21:10 | 14.77 | 10.98 |
| May | 0.114767E+10 | 851.19 | 24-MAY-19:00 | 13.00 | 10.31 | 0.112346E+09 | 70.29 | 30-MAY-20:19 | 9.87 | 8.89 |
| June | 0.135582E+10 | 1232.36 | 13-JUN-18:00 | 23.90 | 16.48 | 0.122595E+09 | 70.31 | 15-JUN-03:20 | 12.00 | 10.35 |
| July | 0.143406E+10 | 1304.86 | 22-JUL-18:40 | 29.33 | 16.94 | 0.127794E+09 | 70.31 | 14-JUL-23:30 | 29.33 | 16.94 |
| August | 0.126691E+10 | 1063.19 | 14-AUG-18:00 | 27.00 | 13.76 | 0.128255E+09 | 70.31 | 29-AUG-02:49 | 13.83 | 11.07 |
| September | 0.103744E+10 | 871.59 | 13-SEP-17:00 | 23.00 | 15.75 | 0.120099E+09 | 70.31 | 14-SEP-01:10 | 12.00 | 10.35 |
| October | 0.969221E+09 | 595.80 | 07-OCT-04:00 | 2.00 | 2.00 | 92716969.07 | 65.25 | 01-OCT-20:10 | 2.00 | 2.00 |
| November | 0.624045E+09 | 525.54 | 10-NOV-22:00 | 3.00 | 3.00 | 76121757.30 | 49.36 | 08-NOV-21:10 | 3.00 | 3.00 |
| December | 0.295676E+09 | 397.66 | 20-DEC-20:00 | 6.00 | 6.00 | 77895312.84 | 42.51 | 17-DEC-22:00 | 6.00 | 6.00 |
| Annual Sum or Average | 0.110831E+11 | 0.118278E+10 | ||||||||
| Minimum of Months | 0.295676E+09 | 397.66 | 2.00 | 2.00 | 70417909.14 | 42.51 | 2.00 | 2.00 | ||
| Maximum of Months | 0.143406E+10 | 1304.86 | 29.33 | 16.94 | 0.128255E+09 | 70.31 | 29.33 | 16.94 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.534487E+09 | 528.00 | 19-JAN-18:35 | 3.67 | 2.94 | 78095854.66 | 44.92 | 29-JAN-21:10 | 8.00 | 7.45 |
| February | 0.503369E+09 | 487.04 | 27-FEB-19:00 | 5.00 | 5.00 | 70416608.86 | 44.35 | 07-FEB-21:10 | 5.00 | 5.00 |
| March | 0.824869E+09 | 540.57 | 21-MAR-21:50 | 3.23 | 2.35 | 79326813.22 | 50.35 | 25-MAR-20:10 | 9.83 | 8.82 |
| April | 0.109284E+10 | 980.58 | 30-APR-18:50 | 24.00 | 13.14 | 97419022.74 | 70.31 | 29-APR-23:40 | 24.00 | 13.14 |
| May | 0.114952E+10 | 838.29 | 24-MAY-19:00 | 13.00 | 10.31 | 0.112561E+09 | 70.31 | 24-MAY-22:10 | 9.00 | 8.43 |
| June | 0.135496E+10 | 1221.61 | 13-JUN-18:00 | 23.90 | 16.48 | 0.122556E+09 | 70.31 | 28-JUN-01:30 | 10.95 | 10.43 |
| July | 0.143419E+10 | 1295.90 | 22-JUL-18:40 | 29.33 | 16.94 | 0.127794E+09 | 70.31 | 21-JUL-01:49 | 29.33 | 16.94 |
| August | 0.127013E+10 | 1056.16 | 14-AUG-17:50 | 27.00 | 13.86 | 0.128250E+09 | 70.31 | 29-AUG-02:49 | 13.83 | 11.07 |
| September | 0.104557E+10 | 866.72 | 13-SEP-16:50 | 23.00 | 15.83 | 0.120228E+09 | 70.31 | 02-SEP-02:30 | 23.00 | 15.83 |
| October | 0.970112E+09 | 596.14 | 07-OCT-04:00 | 2.00 | 2.00 | 92800784.55 | 65.29 | 01-OCT-20:10 | 2.00 | 2.00 |
| November | 0.624090E+09 | 522.61 | 10-NOV-22:00 | 3.00 | 3.00 | 76115501.57 | 49.33 | 08-NOV-21:10 | 3.00 | 3.00 |
| December | 0.297354E+09 | 399.31 | 20-DEC-20:00 | 6.00 | 6.00 | 77895318.37 | 42.51 | 17-DEC-22:00 | 6.00 | 6.00 |
| Annual Sum or Average | 0.111015E+11 | 0.118346E+10 | ||||||||
| Minimum of Months | 0.297354E+09 | 399.31 | 2.00 | 2.00 | 70416608.86 | 42.51 | 2.00 | 2.00 | ||
| Maximum of Months | 0.143419E+10 | 1295.90 | 29.33 | 16.94 | 0.128250E+09 | 70.31 | 29.33 | 16.94 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.105579E+10 | 800.67 | 11-JAN-19:00 | -5.0 | -6.0 | 83621527.80 | 63.71 | 21-JAN-16:10 | 5.75 | 4.88 |
| February | 0.102820E+10 | 750.16 | 17-FEB-21:00 | -3.0 | -3.0 | 74614501.34 | 66.76 | 04-FEB-16:10 | -3.0 | -3.0 |
| March | 0.105189E+10 | 613.15 | 02-MAR-21:00 | 1.00 | 0.59 | 79366319.74 | 58.90 | 20-MAR-17:10 | 8.83 | 5.63 |
| April | 0.158466E+10 | 1889.38 | 30-APR-14:10 | 23.17 | 12.84 | 0.111855E+09 | 70.32 | 09-APR-18:49 | 23.17 | 12.84 |
| May | 0.149335E+10 | 1388.40 | 22-MAY-15:10 | 23.83 | 15.94 | 0.116772E+09 | 70.30 | 01-MAY-02:09 | 23.83 | 15.94 |
| June | 0.169131E+10 | 1544.19 | 13-JUN-14:10 | 25.25 | 17.52 | 0.119110E+09 | 70.32 | 02-JUN-23:10 | 25.25 | 17.52 |
| July | 0.190730E+10 | 1806.48 | 22-JUL-13:40 | 28.00 | 16.51 | 0.128574E+09 | 70.31 | 29-JUL-03:09 | 12.00 | 10.91 |
| August | 0.204373E+10 | 1761.56 | 14-AUG-14:30 | 24.50 | 16.32 | 0.123887E+09 | 70.31 | 23-AUG-02:39 | 10.33 | 8.09 |
| September | 0.206449E+10 | 1907.87 | 27-SEP-13:30 | 21.50 | 13.33 | 0.122773E+09 | 70.31 | 22-SEP-00:30 | 21.50 | 13.33 |
| October | 0.136833E+10 | 1526.70 | 03-OCT-14:10 | 14.00 | 9.33 | 0.107121E+09 | 70.31 | 12-OCT-19:10 | 12.00 | 10.91 |
| November | 0.101499E+10 | 672.68 | 28-NOV-21:00 | -1.0 | -1.8 | 82168809.44 | 65.03 | 05-NOV-15:39 | -1.0 | -1.8 |
| December | 0.658891E+09 | 709.81 | 26-DEC-20:00 | -2.0 | -2.4 | 78670432.85 | 48.02 | 18-DEC-18:30 | -2.0 | -2.4 |
| Annual Sum or Average | 0.169629E+11 | 0.122853E+10 | ||||||||
| Minimum of Months | 0.658891E+09 | 613.15 | -5.0 | -6.0 | 74614501.34 | 48.02 | -3.0 | -3.0 | ||
| Maximum of Months | 0.206449E+10 | 1907.87 | 28.00 | 17.52 | 0.128574E+09 | 70.32 | 25.25 | 17.52 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.105630E+10 | 800.57 | 11-JAN-19:00 | -5.0 | -6.0 | 83631203.26 | 63.77 | 21-JAN-16:10 | 5.75 | 4.88 |
| February | 0.102652E+10 | 749.73 | 17-FEB-21:00 | -3.0 | -3.0 | 74557127.58 | 66.71 | 04-FEB-16:10 | -3.0 | -3.0 |
| March | 0.105153E+10 | 612.94 | 02-MAR-21:00 | 1.00 | 0.59 | 79363273.05 | 58.84 | 20-MAR-17:10 | 8.83 | 5.63 |
| April | 0.159323E+10 | 1894.61 | 30-APR-14:10 | 23.17 | 12.84 | 0.112012E+09 | 70.31 | 29-APR-00:49 | 23.17 | 12.84 |
| May | 0.149798E+10 | 1391.93 | 22-MAY-14:20 | 23.33 | 15.87 | 0.116842E+09 | 70.32 | 08-MAY-19:19 | 23.33 | 15.87 |
| June | 0.169038E+10 | 1548.39 | 13-JUN-14:10 | 25.25 | 17.52 | 0.119077E+09 | 70.31 | 16-JUN-01:10 | 10.92 | 9.33 |
| July | 0.190736E+10 | 1812.64 | 22-JUL-13:40 | 28.00 | 16.51 | 0.128582E+09 | 70.31 | 06-JUL-00:49 | 28.00 | 16.51 |
| August | 0.204642E+10 | 1765.40 | 14-AUG-14:20 | 24.33 | 16.41 | 0.123885E+09 | 70.31 | 24-AUG-01:49 | 12.00 | 9.30 |
| September | 0.207017E+10 | 1912.00 | 27-SEP-13:30 | 21.50 | 13.33 | 0.122790E+09 | 70.31 | 30-SEP-01:00 | 9.00 | 6.57 |
| October | 0.137011E+10 | 1530.24 | 03-OCT-14:10 | 14.00 | 9.33 | 0.107161E+09 | 70.31 | 12-OCT-19:10 | 12.00 | 10.91 |
| November | 0.101523E+10 | 672.90 | 28-NOV-21:00 | -1.0 | -1.8 | 82159438.31 | 64.98 | 11-NOV-16:10 | -1.0 | -1.8 |
| December | 0.660996E+09 | 709.94 | 26-DEC-20:00 | -2.0 | -2.4 | 78676497.14 | 48.04 | 18-DEC-18:30 | -2.0 | -2.4 |
| Annual Sum or Average | 0.169862E+11 | 0.122873E+10 | ||||||||
| Minimum of Months | 0.660996E+09 | 612.94 | -5.0 | -6.0 | 74557127.58 | 48.04 | -3.0 | -3.0 | ||
| Maximum of Months | 0.207017E+10 | 1912.00 | 28.00 | 17.52 | 0.128582E+09 | 70.32 | 28.00 | 16.51 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.214219E+09 | 773.12 | 15-JAN-15:00 | 8.00 | 6.09 | 79151254.98 | 70.36 | 15-JAN-16:30 | 6.00 | 5.06 |
| February | 0.289141E+09 | 1168.41 | 27-FEB-16:10 | 8.00 | 6.56 | 71330320.49 | 70.27 | 04-FEB-16:10 | 8.00 | 6.56 |
| March | 0.259580E+09 | 526.80 | 10-MAR-20:20 | 3.67 | 2.82 | 76171386.66 | 69.15 | 20-MAR-17:10 | 8.83 | 5.63 |
| April | 0.124208E+10 | 3321.31 | 30-APR-16:10 | 24.00 | 13.04 | 91891584.64 | 70.34 | 22-APR-21:10 | 24.00 | 13.04 |
| May | 0.117740E+10 | 2792.06 | 22-MAY-16:10 | 22.33 | 15.17 | 92827916.43 | 70.36 | 06-MAY-20:19 | 22.33 | 15.17 |
| June | 0.163345E+10 | 3263.08 | 13-JUN-17:10 | 26.48 | 17.38 | 0.100437E+09 | 70.35 | 13-JUN-23:19 | 12.67 | 12.30 |
| July | 0.198325E+10 | 3495.69 | 22-JUL-16:10 | 29.00 | 16.57 | 0.113161E+09 | 70.36 | 05-JUL-22:10 | 29.00 | 16.57 |
| August | 0.194966E+10 | 3186.51 | 14-AUG-16:05 | 26.17 | 15.64 | 0.109821E+09 | 70.35 | 28-AUG-22:40 | 13.73 | 11.79 |
| September | 0.160942E+10 | 2861.08 | 12-SEP-15:30 | 21.50 | 15.72 | 0.100935E+09 | 70.36 | 26-SEP-20:00 | 12.00 | 10.35 |
| October | 0.597380E+09 | 2045.35 | 07-OCT-15:20 | 18.67 | 9.96 | 84425029.27 | 70.32 | 11-OCT-18:30 | 9.00 | 8.18 |
| November | 0.188914E+09 | 659.29 | 11-NOV-14:20 | 9.00 | 7.01 | 76140153.61 | 70.27 | 05-NOV-15:39 | 9.00 | 7.01 |
| December | 77304258.67 | 568.25 | 26-DEC-16:20 | 2.33 | 1.24 | 78259262.19 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.112218E+11 | 0.107455E+10 | ||||||||
| Minimum of Months | 77304258.67 | 526.80 | 2.33 | 1.24 | 71330320.49 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.198325E+10 | 3495.69 | 29.00 | 17.38 | 0.113161E+09 | 70.36 | 29.00 | 16.57 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 25700988.14 | 423.03 | 19-JAN-16:30 | 7.00 | 6.74 | 77896111.24 | 42.51 | 11-JAN-06:49 | 7.00 | 6.74 |
| February | 46473893.59 | 485.10 | 19-FEB-17:12 | 5.00 | 3.94 | 70391158.42 | 42.51 | 04-FEB-22:00 | 5.00 | 3.94 |
| March | 0.129884E+09 | 460.82 | 23-MAR-19:10 | 5.83 | 4.52 | 78146473.76 | 46.36 | 23-MAR-17:19 | 5.83 | 4.52 |
| April | 0.688040E+09 | 2251.17 | 30-APR-17:20 | 24.00 | 12.77 | 87063052.40 | 70.33 | 28-APR-21:10 | 24.00 | 12.77 |
| May | 0.811884E+09 | 2164.95 | 22-MAY-16:05 | 22.33 | 15.17 | 92039401.30 | 70.35 | 11-MAY-20:30 | 22.33 | 15.17 |
| June | 0.130062E+10 | 2941.59 | 13-JUN-17:30 | 25.45 | 17.05 | 0.103203E+09 | 70.36 | 08-JUN-20:19 | 25.45 | 17.05 |
| July | 0.150494E+10 | 2886.63 | 22-JUL-17:30 | 29.50 | 16.69 | 0.112163E+09 | 70.35 | 22-JUL-01:39 | 29.50 | 16.69 |
| August | 0.120026E+10 | 2335.42 | 14-AUG-16:40 | 26.67 | 14.92 | 0.111564E+09 | 70.34 | 03-AUG-21:10 | 26.67 | 14.92 |
| September | 0.732833E+09 | 1785.31 | 13-SEP-16:30 | 23.00 | 15.99 | 95084989.90 | 70.33 | 09-SEP-20:19 | 23.00 | 15.99 |
| October | 0.228440E+09 | 501.27 | 03-OCT-19:00 | 6.00 | 5.05 | 80498831.70 | 61.14 | 03-OCT-17:10 | 6.00 | 5.05 |
| November | 33990229.43 | 380.37 | 10-NOV-16:40 | 8.33 | 7.19 | 75384659.96 | 42.51 | 29-NOV-06:49 | -1.0 | -1.5 |
| December | 1097.89 | 1.83 | 02-DEC-13:40 | 9.00 | 7.93 | 77895344.63 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.670307E+10 | 0.106133E+10 | ||||||||
| Minimum of Months | 1097.89 | 1.83 | 5.00 | 3.94 | 70391158.42 | 42.51 | -1.0 | -1.5 | ||
| Maximum of Months | 0.150494E+10 | 2941.59 | 29.50 | 17.05 | 0.112163E+09 | 70.36 | 29.50 | 17.05 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.213238E+09 | 725.35 | 11-JAN-14:10 | -2.0 | -3.7 | 79180525.63 | 67.80 | 15-JAN-16:10 | 6.67 | 5.70 |
| February | 0.271286E+09 | 942.41 | 04-FEB-14:20 | 9.00 | 6.28 | 70818631.31 | 70.27 | 04-FEB-16:10 | 7.00 | 5.54 |
| March | 0.266563E+09 | 541.83 | 25-MAR-12:00 | 12.00 | 8.90 | 75993561.57 | 65.26 | 25-MAR-15:09 | 11.00 | 9.40 |
| April | 0.127191E+10 | 2853.46 | 30-APR-13:50 | 22.83 | 12.83 | 91958119.95 | 70.35 | 26-APR-19:40 | 22.83 | 12.83 |
| May | 0.116397E+10 | 2370.52 | 22-MAY-14:10 | 23.17 | 15.81 | 92449202.10 | 70.35 | 28-MAY-18:40 | 11.33 | 7.30 |
| June | 0.159061E+10 | 2710.26 | 13-JUN-13:30 | 24.55 | 17.26 | 99744088.16 | 70.34 | 22-JUN-20:40 | 12.00 | 11.10 |
| July | 0.192730E+10 | 3152.74 | 22-JUL-13:30 | 28.00 | 16.51 | 0.113287E+09 | 70.36 | 12-JUL-22:49 | 28.00 | 16.51 |
| August | 0.199341E+10 | 2697.75 | 14-AUG-14:10 | 24.17 | 16.49 | 0.109845E+09 | 70.35 | 24-AUG-21:00 | 14.00 | 10.27 |
| September | 0.166736E+10 | 2516.55 | 12-SEP-12:40 | 20.33 | 16.13 | 0.101196E+09 | 70.36 | 05-SEP-18:00 | 20.33 | 16.13 |
| October | 0.608831E+09 | 1696.65 | 07-OCT-13:40 | 17.00 | 9.65 | 84351340.62 | 70.34 | 05-OCT-18:30 | 17.00 | 9.65 |
| November | 0.190407E+09 | 618.87 | 11-NOV-13:40 | 9.00 | 7.15 | 76029347.24 | 68.02 | 05-NOV-15:39 | 9.00 | 7.15 |
| December | 86104755.13 | 559.68 | 26-DEC-16:10 | 2.67 | 1.50 | 78267742.24 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.112510E+11 | 0.107312E+10 | ||||||||
| Minimum of Months | 86104755.13 | 541.83 | -2.0 | -3.7 | 70818631.31 | 42.51 | 1.00 | 0.58 | ||
| Maximum of Months | 0.199341E+10 | 3152.74 | 28.00 | 17.26 | 0.113287E+09 | 70.36 | 28.00 | 16.51 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 14498923.01 | 262.48 | 23-JAN-13:00 | 11.00 | 9.86 | 77895344.65 | 42.51 | 11-JAN-06:49 | 11.00 | 9.86 |
| February | 15105989.59 | 248.53 | 27-FEB-17:02 | 7.83 | 6.89 | 70357085.48 | 42.51 | 04-FEB-22:00 | 7.83 | 6.89 |
| March | 0.122911E+09 | 390.35 | 30-MAR-17:25 | 8.00 | 5.20 | 78065418.71 | 46.39 | 25-MAR-20:10 | 8.00 | 5.20 |
| April | 0.704634E+09 | 1507.11 | 30-APR-16:20 | 24.00 | 12.95 | 87138659.51 | 70.29 | 28-APR-20:40 | 24.00 | 12.95 |
| May | 0.791682E+09 | 1506.73 | 22-MAY-15:10 | 23.83 | 15.94 | 91658381.42 | 70.27 | 21-MAY-20:40 | 23.83 | 15.94 |
| June | 0.124385E+10 | 1991.86 | 13-JUN-16:15 | 26.67 | 17.64 | 0.102920E+09 | 70.36 | 11-JUN-20:49 | 26.67 | 17.64 |
| July | 0.142790E+10 | 2164.17 | 22-JUL-16:20 | 29.00 | 16.57 | 0.112230E+09 | 70.36 | 08-JUL-20:19 | 29.00 | 16.57 |
| August | 0.121531E+10 | 1624.63 | 14-AUG-16:14 | 26.33 | 15.41 | 0.111713E+09 | 70.33 | 07-AUG-21:00 | 26.33 | 15.41 |
| September | 0.727219E+09 | 1185.88 | 13-SEP-16:05 | 23.00 | 16.14 | 95689861.79 | 70.29 | 11-SEP-20:19 | 23.00 | 16.14 |
| October | 0.237970E+09 | 486.44 | 05-OCT-20:00 | 5.00 | 4.09 | 80060215.65 | 56.35 | 07-OCT-17:10 | 14.33 | 8.93 |
| November | 20029242.58 | 377.16 | 10-NOV-16:40 | 8.33 | 7.19 | 75371597.06 | 42.51 | 29-NOV-06:49 | -1.0 | -1.5 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 77895344.63 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.652111E+10 | 0.106099E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 4.00 | 3.53 | 70357085.48 | 42.51 | -1.0 | -1.5 | ||
| Maximum of Months | 0.142790E+10 | 2164.17 | 29.00 | 17.64 | 0.112230E+09 | 70.36 | 29.00 | 17.64 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 52463170.17 | 271.20 | 19-JAN-16:10 | 7.67 | 7.22 | 77895344.66 | 42.51 | 11-JAN-06:49 | 7.67 | 7.22 |
| February | 55308421.48 | 401.95 | 27-FEB-17:17 | 7.67 | 6.81 | 70357089.95 | 42.51 | 18-FEB-06:49 | 7.67 | 6.81 |
| March | 0.223062E+09 | 413.08 | 30-MAR-17:50 | 7.33 | 4.86 | 78165286.19 | 47.57 | 25-MAR-20:10 | 7.33 | 4.86 |
| April | 0.671651E+09 | 1211.89 | 30-APR-16:30 | 24.00 | 12.86 | 86817376.43 | 70.30 | 28-APR-20:49 | 24.00 | 12.86 |
| May | 0.796565E+09 | 1191.92 | 22-MAY-16:05 | 22.33 | 15.17 | 92700240.18 | 70.31 | 22-MAY-22:00 | 14.00 | 12.24 |
| June | 0.110727E+10 | 1692.08 | 13-JUN-17:30 | 25.45 | 17.05 | 0.107328E+09 | 70.32 | 17-JUN-21:10 | 12.00 | 12.00 |
| July | 0.121851E+10 | 1769.28 | 22-JUL-16:30 | 29.00 | 16.57 | 0.116165E+09 | 70.35 | 18-JUL-00:40 | 29.00 | 16.57 |
| August | 0.987165E+09 | 1334.62 | 14-AUG-17:20 | 27.00 | 14.18 | 0.115923E+09 | 70.35 | 15-AUG-22:00 | 14.00 | 12.84 |
| September | 0.712218E+09 | 985.63 | 13-SEP-16:30 | 23.00 | 15.99 | 97748260.93 | 70.33 | 01-SEP-20:19 | 23.00 | 15.99 |
| October | 0.325421E+09 | 497.10 | 05-OCT-20:00 | 5.00 | 4.09 | 80332598.45 | 55.16 | 07-OCT-17:19 | 13.67 | 8.88 |
| November | 74258958.69 | 378.84 | 10-NOV-16:40 | 8.33 | 7.19 | 75385294.01 | 42.51 | 29-NOV-06:49 | -1.0 | -1.5 |
| December | 1129145.82 | 106.30 | 02-DEC-13:40 | 9.00 | 7.93 | 77895344.65 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.622502E+10 | 0.107671E+10 | ||||||||
| Minimum of Months | 1129145.82 | 106.30 | 5.00 | 4.09 | 70357089.95 | 42.51 | -1.0 | -1.5 | ||
| Maximum of Months | 0.121851E+10 | 1769.28 | 29.00 | 17.05 | 0.116165E+09 | 70.35 | 29.00 | 16.57 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 52089394.36 | 263.30 | 19-JAN-16:10 | 7.67 | 7.22 | 77895344.66 | 42.51 | 11-JAN-06:49 | 7.67 | 7.22 |
| February | 54049026.82 | 370.52 | 27-FEB-17:02 | 7.83 | 6.89 | 70357085.49 | 42.51 | 18-FEB-06:49 | 7.83 | 6.89 |
| March | 0.223450E+09 | 412.95 | 30-MAR-17:50 | 7.33 | 4.86 | 78167464.39 | 47.95 | 25-MAR-20:10 | 7.33 | 4.86 |
| April | 0.677240E+09 | 1205.37 | 30-APR-16:30 | 24.00 | 12.86 | 86939609.98 | 70.29 | 28-APR-20:49 | 24.00 | 12.86 |
| May | 0.799928E+09 | 1187.47 | 22-MAY-16:10 | 22.33 | 15.17 | 92740791.84 | 70.27 | 23-MAY-20:10 | 13.67 | 10.55 |
| June | 0.110986E+10 | 1668.89 | 13-JUN-17:30 | 25.45 | 17.05 | 0.107277E+09 | 70.36 | 16-JUN-20:30 | 12.50 | 11.11 |
| July | 0.122099E+10 | 1755.44 | 22-JUL-16:20 | 29.00 | 16.57 | 0.116175E+09 | 70.34 | 29-JUL-20:10 | 14.00 | 12.24 |
| August | 0.995052E+09 | 1319.71 | 14-AUG-17:10 | 27.00 | 14.28 | 0.115911E+09 | 70.36 | 19-AUG-21:10 | 12.17 | 10.98 |
| September | 0.718396E+09 | 977.68 | 13-SEP-16:15 | 23.00 | 16.07 | 97906294.11 | 70.34 | 24-SEP-20:10 | 13.67 | 12.03 |
| October | 0.326095E+09 | 495.89 | 05-OCT-20:00 | 5.00 | 4.09 | 80330155.65 | 55.10 | 07-OCT-17:19 | 13.67 | 8.88 |
| November | 73778524.47 | 378.68 | 10-NOV-16:40 | 8.33 | 7.19 | 75384651.29 | 42.51 | 29-NOV-06:49 | -1.0 | -1.5 |
| December | 1138194.21 | 106.87 | 02-DEC-13:40 | 9.00 | 7.93 | 77895344.65 | 42.51 | 30-DEC-22:00 | 1.00 | 0.58 |
| Annual Sum or Average | 0.625207E+10 | 0.107698E+10 | ||||||||
| Minimum of Months | 1138194.21 | 106.87 | 5.00 | 4.09 | 70357085.49 | 42.51 | -1.0 | -1.5 | ||
| Maximum of Months | 0.122099E+10 | 1755.44 | 29.00 | 17.05 | 0.116175E+09 | 70.36 | 24.00 | 12.86 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.336799E+09 | 831.26 | 15-JAN-13:50 | 9.17 | 6.97 | 79782710.83 | 70.27 | 15-JAN-16:19 | 6.33 | 5.38 |
| February | 0.391345E+09 | 1133.81 | 04-FEB-14:30 | 9.00 | 6.35 | 71759349.10 | 70.33 | 19-FEB-16:00 | 6.00 | 4.60 |
| March | 0.393083E+09 | 549.26 | 10-MAR-21:00 | 3.00 | 3.00 | 76602484.72 | 64.88 | 20-MAR-17:10 | 8.83 | 5.63 |
| April | 0.123423E+10 | 2489.22 | 30-APR-14:10 | 23.17 | 12.84 | 94198909.19 | 70.36 | 30-APR-23:19 | 11.63 | 8.77 |
| May | 0.115001E+10 | 1985.89 | 22-MAY-14:40 | 23.67 | 15.97 | 95111938.74 | 70.35 | 26-MAY-19:19 | 10.00 | 9.41 |
| June | 0.144367E+10 | 2268.62 | 13-JUN-14:10 | 25.25 | 17.52 | 0.104764E+09 | 70.36 | 02-JUN-20:40 | 25.25 | 17.52 |
| July | 0.170666E+10 | 2630.72 | 22-JUL-13:50 | 28.00 | 16.51 | 0.117433E+09 | 70.35 | 08-JUL-20:00 | 28.00 | 16.51 |
| August | 0.175455E+10 | 2341.42 | 14-AUG-14:30 | 24.50 | 16.32 | 0.114348E+09 | 70.35 | 31-AUG-22:10 | 12.13 | 10.56 |
| September | 0.159321E+10 | 2268.17 | 11-SEP-14:10 | 21.17 | 15.98 | 0.106057E+09 | 70.36 | 25-SEP-23:30 | 14.50 | 10.26 |
| October | 0.740604E+09 | 1582.66 | 07-OCT-15:10 | 18.83 | 10.03 | 86759744.09 | 70.35 | 11-OCT-18:40 | 8.67 | 7.94 |
| November | 0.318054E+09 | 783.14 | 11-NOV-13:40 | 9.00 | 7.15 | 76827841.00 | 70.32 | 05-NOV-16:10 | 9.00 | 7.15 |
| December | 0.149959E+09 | 601.59 | 18-DEC-17:45 | 1.33 | 0.91 | 78341381.20 | 42.88 | 17-DEC-16:10 | 1.33 | 0.91 |
| Annual Sum or Average | 0.112122E+11 | 0.110199E+10 | ||||||||
| Minimum of Months | 0.149959E+09 | 549.26 | 1.33 | 0.91 | 71759349.10 | 42.88 | 1.33 | 0.91 | ||
| Maximum of Months | 0.175455E+10 | 2630.72 | 28.00 | 17.52 | 0.117433E+09 | 70.36 | 28.00 | 17.52 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.336965E+09 | 841.29 | 15-JAN-13:50 | 9.17 | 6.97 | 79789159.78 | 70.27 | 15-JAN-16:19 | 6.33 | 5.38 |
| February | 0.390147E+09 | 1141.09 | 04-FEB-14:30 | 9.00 | 6.35 | 71707402.00 | 70.37 | 19-FEB-16:49 | 5.83 | 4.51 |
| March | 0.393575E+09 | 548.67 | 10-MAR-21:00 | 3.00 | 3.00 | 76596660.89 | 64.67 | 20-MAR-17:10 | 8.83 | 5.63 |
| April | 0.124347E+10 | 2500.30 | 30-APR-14:10 | 23.17 | 12.84 | 94237833.87 | 70.36 | 06-APR-18:40 | 23.17 | 12.84 |
| May | 0.115596E+10 | 1997.56 | 22-MAY-14:20 | 23.33 | 15.87 | 95076051.67 | 70.34 | 07-MAY-20:10 | 23.33 | 15.87 |
| June | 0.144732E+10 | 2274.95 | 13-JUN-14:10 | 25.25 | 17.52 | 0.104645E+09 | 70.36 | 05-JUN-18:30 | 25.25 | 17.52 |
| July | 0.171020E+10 | 2639.51 | 22-JUL-13:50 | 28.00 | 16.51 | 0.117405E+09 | 70.35 | 12-JUL-23:30 | 28.00 | 16.51 |
| August | 0.176238E+10 | 2348.38 | 14-AUG-14:30 | 24.50 | 16.32 | 0.114301E+09 | 70.36 | 01-AUG-21:00 | 24.50 | 16.32 |
| September | 0.160293E+10 | 2277.76 | 11-SEP-14:10 | 21.17 | 15.98 | 0.106054E+09 | 70.36 | 30-SEP-19:19 | 7.00 | 5.55 |
| October | 0.743636E+09 | 1588.19 | 07-OCT-14:30 | 18.00 | 10.02 | 86751363.15 | 70.35 | 05-OCT-18:00 | 18.00 | 10.02 |
| November | 0.317995E+09 | 798.06 | 11-NOV-13:40 | 9.00 | 7.15 | 76816047.36 | 70.28 | 05-NOV-16:19 | 9.00 | 7.15 |
| December | 0.150853E+09 | 601.45 | 18-DEC-17:45 | 1.33 | 0.91 | 78344037.97 | 42.87 | 17-DEC-16:10 | 1.33 | 0.91 |
| Annual Sum or Average | 0.112554E+11 | 0.110172E+10 | ||||||||
| Minimum of Months | 0.150853E+09 | 548.67 | 1.33 | 0.91 | 71707402.00 | 42.87 | 1.33 | 0.91 | ||
| Maximum of Months | 0.176238E+10 | 2639.51 | 28.00 | 17.52 | 0.117405E+09 | 70.37 | 28.00 | 17.52 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 | 1.45 | 0.118805E+09 | 80.83 | 23-JAN-21:10 | 8.83 | 7.44 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 | 5.79 | 0.110470E+09 | 87.36 | 27-FEB-21:10 | 5.83 | 5.83 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 | 3.71 | 0.128866E+09 | 97.93 | 25-MAR-20:10 | 9.83 | 8.82 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 | 1.84 | 0.176311E+09 | 160.90 | 30-APR-20:10 | 16.67 | 12.21 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 | 8.15 | 0.186679E+09 | 155.38 | 22-MAY-20:10 | 16.67 | 12.87 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 | 7.39 | 0.217660E+09 | 167.59 | 13-JUN-20:10 | 16.50 | 13.79 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 | 9.95 | 0.238658E+09 | 175.48 | 22-JUL-20:10 | 25.33 | 16.66 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 | 9.82 | 0.237326E+09 | 160.44 | 14-AUG-20:10 | 20.28 | 12.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 | 10.95 | 0.202893E+09 | 150.20 | 11-SEP-20:10 | 15.67 | 13.48 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 | 5.83 | 0.149545E+09 | 116.77 | 07-OCT-20:10 | 8.00 | 6.07 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 | 4.29 | 0.120227E+09 | 85.20 | 05-NOV-20:10 | 7.00 | 6.40 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 0.109943E+09 | 68.10 | 21-DEC-21:10 | 2.17 | 2.17 |
| Annual Sum or Average | 0.00 | 0.199738E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 1.92 | 1.45 | 0.109943E+09 | 68.10 | 2.17 | 2.17 | ||
| Maximum of Months | 0.00 | 0.00 | 12.43 | 10.95 | 0.238658E+09 | 175.48 | 25.33 | 16.66 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 | 1.45 | 74974030.12 | 69.24 | 19-JAN-06:10 | 5.50 | 4.82 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 | 5.79 | 69110499.55 | 66.15 | 23-FEB-06:10 | 1.83 | 1.83 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 | 3.71 | 82558641.03 | 69.86 | 26-MAR-05:10 | 4.83 | 4.43 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 | 1.84 | 0.119654E+09 | 130.38 | 30-APR-21:49 | 13.83 | 10.30 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 | 8.15 | 0.140185E+09 | 126.37 | 01-MAY-00:10 | 10.47 | 8.15 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 | 7.39 | 0.182004E+09 | 143.18 | 26-JUN-22:10 | 14.17 | 14.07 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 | 9.95 | 0.215671E+09 | 169.04 | 22-JUL-20:10 | 25.33 | 16.66 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 | 9.82 | 0.222768E+09 | 149.66 | 14-AUG-21:49 | 16.37 | 11.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 | 10.95 | 0.191193E+09 | 140.32 | 13-SEP-22:19 | 11.67 | 10.19 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 | 5.83 | 0.127032E+09 | 115.73 | 01-OCT-00:10 | 7.57 | 5.83 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 | 4.29 | 87921869.91 | 78.05 | 01-NOV-05:10 | 5.00 | 4.51 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 72364336.99 | 64.20 | 24-DEC-06:10 | 6.83 | 5.84 |
| Annual Sum or Average | 0.00 | 0.158544E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 1.92 | 1.45 | 69110499.55 | 64.20 | 1.83 | 1.83 | ||
| Maximum of Months | 0.00 | 0.00 | 12.43 | 10.95 | 0.222768E+09 | 169.04 | 25.33 | 16.66 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 | 1.45 | 0.159672E+09 | 97.86 | 21-JAN-21:10 | 0.98 | 0.57 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 | 5.79 | 0.146523E+09 | 97.11 | 04-FEB-22:10 | 3.33 | 3.26 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 | 3.71 | 0.165078E+09 | 101.40 | 25-MAR-20:10 | 9.83 | 8.82 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 | 1.84 | 0.217375E+09 | 158.07 | 30-APR-20:10 | 16.67 | 12.21 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 | 8.15 | 0.239397E+09 | 153.04 | 23-MAY-20:10 | 13.67 | 10.55 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 | 7.39 | 0.257216E+09 | 160.32 | 13-JUN-20:10 | 16.50 | 13.79 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 | 9.95 | 0.270932E+09 | 163.58 | 22-JUL-20:10 | 25.33 | 16.66 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 | 9.82 | 0.271636E+09 | 157.91 | 14-AUG-20:10 | 20.28 | 12.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 | 10.95 | 0.253012E+09 | 154.63 | 13-SEP-20:10 | 14.50 | 12.28 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 | 5.83 | 0.201683E+09 | 138.79 | 01-OCT-20:10 | 9.00 | 6.72 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 | 4.29 | 0.158430E+09 | 99.13 | 11-NOV-21:10 | 2.00 | 2.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 0.149940E+09 | 87.97 | 21-DEC-21:19 | 2.33 | 2.33 |
| Annual Sum or Average | 0.00 | 0.249089E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 1.92 | 1.45 | 0.146523E+09 | 87.97 | 0.98 | 0.57 | ||
| Maximum of Months | 0.00 | 0.00 | 12.43 | 10.95 | 0.271636E+09 | 163.58 | 25.33 | 16.66 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.523336E+09 | 798.97 | 10-JAN-06:00 | -4.0 |
| February | 0.439798E+09 | 722.11 | 17-FEB-04:00 | -2.0 |
| March | 0.494838E+09 | 604.76 | 04-MAR-06:00 | 3.00 |
| April | 28090642.57 | 284.92 | 01-APR-03:00 | 3.20 |
| May | 20909848.92 | 359.56 | 18-MAY-21:03 | 7.17 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 25150993.81 | 269.61 | 28-OCT-02:00 | 8.00 |
| November | 0.204013E+09 | 510.34 | 29-NOV-04:00 | -1.0 |
| December | 0.832996E+09 | 782.77 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.256913E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.832996E+09 | 798.97 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.104290E+10 | 1004.78 | 10-JAN-09:00 | -4.0 |
| February | 0.895711E+09 | 829.80 | 17-FEB-04:00 | -2.0 |
| March | 0.718940E+09 | 665.53 | 04-MAR-06:00 | 3.00 |
| April | 0.132804E+09 | 389.74 | 02-APR-05:00 | 3.00 |
| May | 48133559.96 | 803.61 | 21-MAY-07:01 | 11.08 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 92118578.78 | 686.12 | 24-OCT-16:01 | 9.83 |
| November | 0.491072E+09 | 743.59 | 29-NOV-04:00 | -1.0 |
| December | 0.120614E+10 | 917.83 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.462782E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.120614E+10 | 1004.78 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.292410E+09 | 8927.69 | 17-JAN-08:61 | 7.17 |
| February | 0.182342E+09 | 8886.83 | 22-FEB-08:61 | 7.17 |
| March | 0.217047E+09 | 8932.62 | 20-MAR-07:01 | 7.33 |
| April | 15505243.76 | 8821.34 | 03-APR-07:01 | 4.67 |
| May | 10468606.44 | 233.55 | 21-MAY-18:00 | 20.00 |
| June | 24293895.62 | 449.32 | 13-JUN-16:25 | 26.75 |
| July | 41653452.39 | 519.34 | 21-JUL-16:12 | 28.33 |
| August | 25547636.99 | 430.92 | 14-AUG-16:12 | 26.33 |
| September | 13200641.39 | 256.55 | 11-SEP-16:25 | 22.50 |
| October | 2579801.24 | 5073.50 | 23-OCT-07:01 | 4.50 |
| November | 67356081.45 | 8866.27 | 21-NOV-08:61 | 5.17 |
| December | 0.331511E+09 | 8875.74 | 05-DEC-08:61 | 6.17 |
| Annual Sum or Average | 0.122392E+10 | |||
| Minimum of Months | 2579801.24 | 233.55 | 4.50 | |
| Maximum of Months | 0.331511E+09 | 8932.62 | 28.33 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.103332E+10 | 990.30 | 11-JAN-05:00 | -3.0 |
| February | 0.925619E+09 | 888.72 | 17-FEB-04:00 | -2.0 |
| March | 0.708152E+09 | 703.40 | 04-MAR-06:00 | 3.00 |
| April | 0.114732E+09 | 409.48 | 02-APR-05:00 | 3.00 |
| May | 42680354.79 | 375.94 | 18-MAY-21:03 | 7.17 |
| June | 6308.37 | 10.51 | 08-JUN-04:00 | 6.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 85678496.73 | 907.08 | 24-OCT-16:01 | 9.83 |
| November | 0.476564E+09 | 723.60 | 29-NOV-04:00 | -1.0 |
| December | 0.116774E+10 | 931.42 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.455449E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -3.0 | |
| Maximum of Months | 0.116774E+10 | 990.30 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.330949E+09 | 512.38 | 12-JAN-02:70 | -4.0 |
| February | 0.270943E+09 | 421.52 | 18-FEB-04:00 | -2.0 |
| March | 0.149450E+09 | 281.52 | 04-MAR-06:00 | 3.00 |
| April | 7330110.83 | 104.86 | 01-APR-02:30 | 3.35 |
| May | 382473.62 | 42.53 | 22-MAY-15:00 | 24.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 177420.20 | 85.83 | 24-OCT-16:01 | 9.83 |
| November | 71816400.73 | 318.33 | 29-NOV-04:00 | -1.0 |
| December | 0.354605E+09 | 451.09 | 30-DEC-02:70 | -2.0 |
| Annual Sum or Average | 0.118565E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.354605E+09 | 512.38 | 24.00 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.330323E+09 | 512.81 | 12-JAN-02:70 | -4.0 |
| February | 0.272091E+09 | 423.59 | 18-FEB-04:00 | -2.0 |
| March | 0.149540E+09 | 283.72 | 04-MAR-06:00 | 3.00 |
| April | 7363729.02 | 105.31 | 01-APR-02:30 | 3.35 |
| May | 398255.72 | 42.20 | 22-MAY-15:00 | 24.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 181879.58 | 88.37 | 24-OCT-16:01 | 9.83 |
| November | 71583172.73 | 316.87 | 29-NOV-04:00 | -1.0 |
| December | 0.352968E+09 | 451.26 | 30-DEC-02:70 | -2.0 |
| Annual Sum or Average | 0.118445E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.352968E+09 | 512.81 | 24.00 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 62704287.18 | 295.97 | 10-JAN-06:00 | -4.0 |
| February | 50745741.53 | 301.96 | 17-FEB-04:00 | -2.0 |
| March | 54947020.01 | 216.33 | 04-MAR-06:00 | 3.00 |
| April | 163851.11 | 18.08 | 01-APR-03:00 | 3.20 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 4912390.52 | 104.18 | 29-NOV-04:00 | -1.0 |
| December | 0.146047E+09 | 317.06 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.319520E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.146047E+09 | 317.06 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.120052E+09 | 400.60 | 10-JAN-06:00 | -4.0 |
| February | 93606279.81 | 372.78 | 17-FEB-04:00 | -2.0 |
| March | 0.108530E+09 | 275.33 | 04-MAR-06:00 | 3.00 |
| April | 687120.75 | 48.67 | 01-APR-03:00 | 3.20 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 14559887.91 | 154.50 | 29-NOV-04:00 | -1.0 |
| December | 0.250035E+09 | 394.11 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.587470E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.250035E+09 | 400.60 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.100920E+09 | 566.79 | 10-JAN-06:00 | -4.0 |
| February | 65753648.04 | 423.97 | 17-FEB-04:00 | -2.0 |
| March | 25814927.48 | 294.13 | 04-MAR-06:00 | 3.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 2306087.24 | 165.25 | 28-OCT-02:00 | 8.00 |
| November | 73329117.46 | 414.14 | 29-NOV-04:00 | -1.0 |
| December | 0.364862E+09 | 628.22 | 28-DEC-02:00 | 2.00 |
| Annual Sum or Average | 0.632985E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.364862E+09 | 628.22 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.301537E+09 | 724.23 | 10-JAN-06:00 | -4.0 |
| February | 0.201516E+09 | 525.60 | 17-FEB-04:00 | -2.0 |
| March | 58251352.63 | 336.48 | 04-MAR-06:00 | 3.00 |
| April | 1393.48 | 1.73 | 01-APR-03:00 | 3.20 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 8331529.50 | 198.31 | 28-OCT-02:00 | 8.00 |
| November | 0.195764E+09 | 621.04 | 29-NOV-04:00 | -1.0 |
| December | 0.578535E+09 | 746.01 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.134394E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.578535E+09 | 746.01 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.100270E+09 | 580.27 | 10-JAN-06:00 | -4.0 |
| February | 72430066.42 | 486.26 | 17-FEB-04:00 | -2.0 |
| March | 25557778.74 | 322.25 | 04-MAR-06:00 | 3.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 3017523.74 | 171.56 | 28-OCT-02:00 | 8.00 |
| November | 70343459.75 | 394.04 | 29-NOV-04:00 | -1.0 |
| December | 0.349891E+09 | 631.15 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.621509E+09 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.349891E+09 | 631.15 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.291588E+09 | 739.54 | 10-JAN-06:00 | -4.0 |
| February | 0.207803E+09 | 593.50 | 17-FEB-04:00 | -2.0 |
| March | 57822354.85 | 375.91 | 04-MAR-06:00 | 3.00 |
| April | 318275.63 | 30.91 | 02-APR-05:00 | 3.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 8473565.01 | 201.61 | 28-OCT-02:00 | 8.00 |
| November | 0.186356E+09 | 600.45 | 29-NOV-04:00 | -1.0 |
| December | 0.545210E+09 | 765.75 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.129757E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.545210E+09 | 765.75 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 25911782.34 | 239.57 | 11-JAN-05:00 | -3.0 |
| February | 5951749.01 | 145.20 | 17-FEB-04:00 | -2.0 |
| March | 18665.92 | 19.72 | 04-MAR-06:00 | 3.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 7179060.16 | 167.93 | 29-NOV-04:00 | -1.0 |
| December | 38972924.60 | 255.12 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 78034182.04 | |||
| Minimum of Months | 0.00 | 0.00 | -3.0 | |
| Maximum of Months | 38972924.60 | 255.12 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 25885869.96 | 240.35 | 11-JAN-05:00 | -3.0 |
| February | 6202399.13 | 148.66 | 17-FEB-04:00 | -2.0 |
| March | 23006.34 | 22.12 | 04-MAR-06:00 | 3.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 7122375.04 | 167.46 | 29-NOV-04:00 | -1.0 |
| December | 38754755.49 | 255.74 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 77988405.96 | |||
| Minimum of Months | 0.00 | 0.00 | -3.0 | |
| Maximum of Months | 38754755.49 | 255.74 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1098505.47 | 115.37 | 10-JAN-06:00 | -4.0 |
| February | 271800.42 | 57.36 | 17-FEB-04:00 | -2.0 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 |
| December | 14639715.25 | 159.18 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 16010021.14 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 14639715.25 | 159.18 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1100437.92 | 115.76 | 10-JAN-06:00 | -4.0 |
| February | 310655.73 | 62.46 | 17-FEB-04:00 | -2.0 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 |
| December | 14562632.33 | 159.82 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 15973725.97 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 14562632.33 | 159.82 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.114293E+10 | 1667.25 | 10-JAN-06:00 | -4.0 |
| February | 0.918891E+09 | 1447.19 | 17-FEB-04:00 | -2.0 |
| March | 0.760593E+09 | 1119.89 | 04-MAR-06:00 | 3.00 |
| April | 0.148091E+09 | 684.21 | 11-APR-06:00 | 5.00 |
| May | 0.149470E+09 | 950.41 | 05-MAY-04:50 | 5.83 |
| June | 10970055.79 | 1015.72 | 02-JUN-06:01 | 9.33 |
| July | 1817343.26 | 782.20 | 02-JUL-06:01 | 10.17 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 12946516.65 | 309.43 | 20-SEP-06:00 | 6.00 |
| October | 0.375322E+09 | 824.00 | 19-OCT-04:00 | 6.00 |
| November | 0.918666E+09 | 1413.38 | 29-NOV-04:00 | -1.0 |
| December | 0.176611E+10 | 1637.22 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.620580E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.176611E+10 | 1667.25 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.158660E+10 | 1737.12 | 10-JAN-06:00 | -4.0 |
| February | 0.128224E+10 | 1536.03 | 17-FEB-04:00 | -2.0 |
| March | 0.897042E+09 | 1142.66 | 04-MAR-06:00 | 3.00 |
| April | 0.247509E+09 | 741.91 | 09-APR-05:00 | 1.00 |
| May | 0.182877E+09 | 952.42 | 05-MAY-04:50 | 5.83 |
| June | 11315939.86 | 516.70 | 08-JUN-04:00 | 6.00 |
| July | 2775920.83 | 1049.49 | 02-JUL-06:01 | 10.17 |
| August | 8253.66 | 59.02 | 24-AUG-06:02 | 8.83 |
| September | 43923389.09 | 430.89 | 20-SEP-04:00 | 5.00 |
| October | 0.570497E+09 | 846.60 | 23-OCT-06:40 | 4.00 |
| November | 0.124644E+10 | 1522.15 | 29-NOV-04:00 | -1.0 |
| December | 0.212352E+10 | 1722.55 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.819475E+10 | |||
| Minimum of Months | 8253.66 | 59.02 | -4.0 | |
| Maximum of Months | 0.212352E+10 | 1737.12 | 10.17 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.113828E+10 | 1681.61 | 10-JAN-06:00 | -4.0 |
| February | 0.929292E+09 | 1512.73 | 17-FEB-04:00 | -2.0 |
| March | 0.754830E+09 | 1146.68 | 04-MAR-06:00 | 3.00 |
| April | 0.134588E+09 | 668.25 | 01-APR-05:00 | 2.00 |
| May | 0.142898E+09 | 955.77 | 05-MAY-04:50 | 5.83 |
| June | 12895129.61 | 553.69 | 08-JUN-04:00 | 6.00 |
| July | 973889.25 | 775.04 | 02-JUL-06:01 | 10.17 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 9334830.83 | 313.64 | 20-SEP-06:00 | 6.00 |
| October | 0.369934E+09 | 824.21 | 19-OCT-04:00 | 6.00 |
| November | 0.912960E+09 | 1394.15 | 29-NOV-04:00 | -1.0 |
| December | 0.173489E+10 | 1652.16 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.614088E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.173489E+10 | 1681.61 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.156805E+10 | 1750.57 | 10-JAN-06:00 | -4.0 |
| February | 0.128707E+10 | 1588.24 | 17-FEB-04:00 | -2.0 |
| March | 0.878563E+09 | 1168.51 | 04-MAR-06:00 | 3.00 |
| April | 0.230922E+09 | 732.39 | 01-APR-05:00 | 2.00 |
| May | 0.182050E+09 | 959.75 | 05-MAY-04:50 | 5.83 |
| June | 15035886.13 | 574.86 | 08-JUN-04:00 | 6.00 |
| July | 1495864.40 | 909.63 | 02-JUL-06:01 | 10.17 |
| August | 25698.09 | 20.90 | 23-AUG-05:00 | 9.00 |
| September | 34719351.29 | 424.01 | 20-SEP-04:00 | 5.00 |
| October | 0.554996E+09 | 1021.56 | 24-OCT-16:01 | 9.83 |
| November | 0.122387E+10 | 1510.51 | 29-NOV-04:00 | -1.0 |
| December | 0.207918E+10 | 1736.98 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.805598E+10 | |||
| Minimum of Months | 25698.09 | 20.90 | -4.0 | |
| Maximum of Months | 0.207918E+10 | 1750.57 | 10.17 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.826372E+09 | 1108.11 | 10-JAN-06:00 | -4.0 |
| February | 0.646992E+09 | 1000.01 | 17-FEB-04:00 | -2.0 |
| March | 0.398978E+09 | 681.96 | 04-MAR-06:00 | 3.00 |
| April | 71975655.57 | 389.52 | 01-APR-05:00 | 2.00 |
| May | 43557814.94 | 483.28 | 05-MAY-04:50 | 5.83 |
| June | 1468028.93 | 187.57 | 08-JUN-04:00 | 6.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 1952105.70 | 101.15 | 21-SEP-05:00 | 6.00 |
| October | 0.195243E+09 | 451.97 | 23-OCT-06:00 | 4.00 |
| November | 0.564222E+09 | 938.39 | 29-NOV-04:00 | -1.0 |
| December | 0.111310E+10 | 1087.60 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.386387E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.111310E+10 | 1108.11 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.825940E+09 | 1108.81 | 10-JAN-06:00 | -4.0 |
| February | 0.648468E+09 | 1004.47 | 17-FEB-04:00 | -2.0 |
| March | 0.399314E+09 | 684.33 | 04-MAR-06:00 | 3.00 |
| April | 71905564.93 | 391.41 | 01-APR-05:00 | 2.00 |
| May | 44059445.06 | 484.19 | 05-MAY-04:50 | 5.83 |
| June | 1578076.12 | 195.99 | 08-JUN-04:00 | 6.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 1843081.73 | 101.38 | 21-SEP-05:00 | 6.00 |
| October | 0.195427E+09 | 453.74 | 23-OCT-06:00 | 4.00 |
| November | 0.563862E+09 | 936.76 | 29-NOV-04:00 | -1.0 |
| December | 0.111115E+10 | 1090.04 | 30-DEC-02:00 | -2.0 |
| Annual Sum or Average | 0.386355E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.111115E+10 | 1108.81 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.496979E+09 | 1031.60 | 10-JAN-06:00 | -4.0 |
| February | 0.386243E+09 | 910.87 | 17-FEB-04:00 | -2.0 |
| March | 0.310908E+09 | 657.07 | 04-MAR-06:00 | 3.00 |
| April | 21674658.86 | 310.48 | 01-APR-05:00 | 2.00 |
| May | 27112969.55 | 477.17 | 05-MAY-04:50 | 5.83 |
| June | 1269621.01 | 153.34 | 08-JUN-04:00 | 6.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 83476188.44 | 397.13 | 28-OCT-02:70 | 8.00 |
| November | 0.343629E+09 | 808.50 | 29-NOV-05:00 | 0.00 |
| December | 0.841091E+09 | 1015.80 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.251238E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.841091E+09 | 1031.60 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.497248E+09 | 1032.43 | 10-JAN-06:00 | -4.0 |
| February | 0.388379E+09 | 917.38 | 17-FEB-04:00 | -2.0 |
| March | 0.311724E+09 | 659.77 | 04-MAR-06:00 | 3.00 |
| April | 21545303.68 | 313.96 | 01-APR-05:00 | 2.00 |
| May | 27128889.24 | 478.49 | 05-MAY-04:50 | 5.83 |
| June | 1381454.97 | 161.13 | 08-JUN-04:00 | 6.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 83565263.26 | 396.82 | 28-OCT-02:70 | 8.00 |
| November | 0.343935E+09 | 806.31 | 29-NOV-05:00 | 0.00 |
| December | 0.839969E+09 | 1017.01 | 30-DEC-04:00 | -2.0 |
| Annual Sum or Average | 0.251488E+10 | |||
| Minimum of Months | 0.00 | 0.00 | -4.0 | |
| Maximum of Months | 0.839969E+09 | 1032.43 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1.92 | |
| Maximum of Months | 0.00 | 0.00 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1.92 | |
| Maximum of Months | 0.00 | 0.00 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1.92 | |
| Maximum of Months | 0.00 | 0.00 | 12.43 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.609777E+09 | 582.92 | 03-JAN-08:09 | 0.787690E+09 | 588.62 | 03-JAN-08:09 |
| February | 0.564682E+09 | 582.92 | 01-FEB-08:09 | 0.723971E+09 | 588.62 | 01-FEB-08:09 |
| March | 0.654405E+09 | 582.92 | 01-MAR-08:09 | 0.827804E+09 | 588.62 | 01-MAR-08:09 |
| April | 0.599704E+09 | 582.92 | 03-APR-07:10 | 0.770907E+09 | 588.62 | 03-APR-07:10 |
| May | 0.639529E+09 | 582.92 | 01-MAY-07:10 | 0.814432E+09 | 588.62 | 01-MAY-07:10 |
| June | 0.629456E+09 | 582.92 | 01-JUN-07:10 | 0.797650E+09 | 588.62 | 01-JUN-07:10 |
| July | 0.609777E+09 | 582.92 | 03-JUL-07:10 | 0.787690E+09 | 588.62 | 03-JUL-07:10 |
| August | 0.654405E+09 | 582.92 | 01-AUG-07:10 | 0.827804E+09 | 588.62 | 01-AUG-07:10 |
| September | 0.599704E+09 | 582.92 | 01-SEP-07:10 | 0.770907E+09 | 588.62 | 01-SEP-07:10 |
| October | 0.624653E+09 | 582.92 | 02-OCT-07:10 | 0.801061E+09 | 588.62 | 02-OCT-07:10 |
| November | 0.599704E+09 | 582.92 | 01-NOV-07:10 | 0.770907E+09 | 588.62 | 01-NOV-07:10 |
| December | 0.609777E+09 | 582.92 | 01-DEC-08:09 | 0.787690E+09 | 588.62 | 01-DEC-08:09 |
| Annual Sum or Average | 0.739557E+10 | 0.946851E+10 | ||||
| Minimum of Months | 0.564682E+09 | 582.92 | 0.723971E+09 | 588.62 | ||
| Maximum of Months | 0.654405E+09 | 582.92 | 0.827804E+09 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.123508E+09 | 138.88 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 0.111556E+09 | 138.88 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 0.123508E+09 | 138.88 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 0.119524E+09 | 138.88 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 0.123508E+09 | 138.88 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 0.119524E+09 | 138.88 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 0.123508E+09 | 138.88 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 0.123508E+09 | 138.88 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 0.119524E+09 | 138.88 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 0.123508E+09 | 138.88 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 0.119524E+09 | 138.88 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 0.123508E+09 | 138.88 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.145421E+10 | 0.122128E+11 | ||||
| Minimum of Months | 0.111556E+09 | 138.88 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 0.123508E+09 | 138.88 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.599555E+10 | 4168.07 | 01-JAN-07:10 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.541534E+10 | 4168.07 | 01-FEB-07:10 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.599555E+10 | 4168.07 | 01-MAR-07:10 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.580215E+10 | 4168.07 | 01-APR-06:10 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.599555E+10 | 4168.07 | 01-MAY-06:10 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.580215E+10 | 4168.07 | 01-JUN-06:10 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.599555E+10 | 4168.07 | 01-JUL-06:10 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.599555E+10 | 4168.07 | 01-AUG-06:10 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.580215E+10 | 4168.07 | 01-SEP-06:10 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.599555E+10 | 4168.07 | 01-OCT-06:10 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.580215E+10 | 4168.07 | 01-NOV-06:10 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.599555E+10 | 4168.07 | 01-DEC-07:10 |
| Annual Sum or Average | 0.116881E+11 | 0.705928E+11 | ||||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.541534E+10 | 4168.07 | ||
| Maximum of Months | 0.992689E+09 | 370.63 | 0.599555E+10 | 4168.07 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.992689E+09 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.896622E+09 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.992689E+09 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.960667E+09 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.992689E+09 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.960667E+09 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.992689E+09 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.992689E+09 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.960667E+09 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.992689E+09 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.960667E+09 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.992689E+09 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.116881E+11 | 0.00 | 0.00 | ||
| Minimum of Months | 0.896622E+09 | 370.63 | 0.00 | 0.00 | |
| Maximum of Months | 0.992689E+09 | 370.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106959E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145549E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101700E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106956E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243602E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 308801.98 | 0.191028E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1206983.07 | 0.165399E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 195417.24 | 0.134077E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145863E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144802E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178039E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244927E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1711202.28 | 0.190890E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101700E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1206983.07 | 0.244927E+09 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106877E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145409E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101663E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101112E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 493.18 | 0.232975E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 308802.55 | 0.183248E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1206985.01 | 0.161685E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 195417.89 | 0.129717E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132574E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136533E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177640E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244918E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1711698.62 | 0.185435E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101112E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1206985.01 | 0.244918E+09 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93907577.46 |
| February | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128237E+09 |
| March | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92844693.62 |
| April | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110540E+09 |
| May | 0.250148E+09 | 0.639529E+09 | 0.814432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252939E+09 |
| June | 0.250148E+09 | 0.629456E+09 | 0.797650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 166725.54 | 0.203077E+09 |
| July | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 233266.12 | 0.183988E+09 |
| August | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 62850.59 | 0.153047E+09 |
| September | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157604E+09 |
| October | 0.238778E+09 | 0.624653E+09 | 0.801061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146355E+09 |
| November | 0.227408E+09 | 0.599704E+09 | 0.770907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162299E+09 |
| December | 0.227408E+09 | 0.609777E+09 | 0.787690E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208772E+09 |
| Annual Sum or Average | 0.284259E+10 | 0.739557E+10 | 0.946851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 462842.24 | 0.189361E+10 |
| Minimum of Months | 0.216037E+09 | 0.564682E+09 | 0.723971E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92844693.62 |
| Maximum of Months | 0.261519E+09 | 0.654405E+09 | 0.827804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 233266.12 | 0.252939E+09 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106877E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145409E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101663E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101467E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1000.81 | 0.232786E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 308803.00 | 0.182413E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1206985.66 | 0.162946E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 195418.18 | 0.130715E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135200E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136707E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177640E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244918E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1712207.65 | 0.185874E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101467E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1206985.66 | 0.244918E+09 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64465207.25 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87706922.55 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61324012.53 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1472.13 | 60875974.05 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6355.72 | 0.140486E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 186262.33 | 0.111996E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728023.58 | 99623223.60 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 117871.40 | 79701580.31 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82667293.65 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83088421.84 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107150E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147728E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1039985.16 | 0.112681E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60875974.05 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728023.58 | 0.147728E+09 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64465207.25 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87706922.55 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61324022.69 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1270.59 | 60909344.48 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6150.95 | 0.140504E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 186262.33 | 0.111915E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728023.56 | 99720494.73 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 117871.41 | 79766929.24 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82888721.20 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83102549.76 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107150E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147728E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1039578.84 | 0.112718E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60909344.48 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728023.56 | 0.147728E+09 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64647694.55 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87939096.44 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61388420.17 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65777349.17 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149649E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 186261.84 | 0.117696E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728022.74 | 0.101813E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 117870.96 | 81755787.37 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89834168.45 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89513308.88 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107778E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147773E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1032155.54 | 0.116556E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61388420.17 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728022.74 | 0.149649E+09 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64605953.67 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87875189.33 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61372422.81 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65966271.99 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150290E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 186261.83 | 0.118190E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728022.64 | 0.102123E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 117870.97 | 81863281.22 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89977294.23 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89655656.83 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107723E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147757E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1032155.43 | 0.116740E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61372422.81 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 728022.64 | 0.150290E+09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155507E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212462E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148624E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171297E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.385344E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 438090.13 | 0.293038E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722420.55 | 0.245988E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 277773.14 | 0.195637E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213953E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215855E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258679E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352822E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2438283.82 | 0.284921E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148624E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722420.55 | 0.385344E+09 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153775E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209231E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146846E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160160E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373453E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 438090.66 | 0.291820E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722422.47 | 0.245363E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 277773.89 | 0.194679E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207771E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203531E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255705E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352377E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2438287.02 | 0.279471E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146846E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722422.47 | 0.373453E+09 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155618E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212265E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148755E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172890E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.387442E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 438090.81 | 0.292809E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722423.11 | 0.246109E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 277773.68 | 0.195579E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214391E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.216239E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258789E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352897E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2438287.60 | 0.285378E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148755E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722423.11 | 0.387442E+09 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153773E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209218E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146685E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162412E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376444E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 438091.29 | 0.291666E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722424.35 | 0.245501E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 277774.50 | 0.194671E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210351E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204146E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255669E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352377E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2438290.14 | 0.280291E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146685E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1722424.35 | 0.376444E+09 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92846621.79 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126209E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88944883.76 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97921900.50 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230097E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 264245.72 | 0.177580E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038923.19 | 0.149062E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 167546.76 | 0.118050E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128172E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126138E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154457E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212545E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1470715.67 | 0.170202E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88944883.76 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038923.19 | 0.230097E+09 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92846698.75 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126210E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88948379.17 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98099766.13 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230376E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 264245.73 | 0.177564E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038923.20 | 0.149066E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 167546.76 | 0.118051E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128294E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126204E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154455E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212545E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1470715.69 | 0.170266E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88948379.17 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038923.20 | 0.230376E+09 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95152946.83 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129595E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90945081.47 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105583E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237731E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 264245.29 | 0.178063E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038921.85 | 0.149256E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 167546.20 | 0.118272E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130482E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135290E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159213E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213367E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1470713.34 | 0.174295E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90945081.47 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038921.85 | 0.237731E+09 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95165374.59 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129583E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90962968.91 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105658E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237834E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 264245.30 | 0.178044E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038921.88 | 0.149262E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 167546.21 | 0.118271E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130494E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135318E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159223E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213376E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1470713.39 | 0.174319E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90962968.91 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1038921.88 | 0.237834E+09 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205712E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281801E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196857E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.216022E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.476006E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 564471.93 | 0.361300E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246384.20 | 0.305524E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 359352.25 | 0.243451E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259466E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273546E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342629E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467891E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3170208.38 | 0.363021E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196857E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246384.20 | 0.476006E+09 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203895E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.277433E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194519E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205320E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.463955E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 564472.05 | 0.357631E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246384.87 | 0.302281E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 359352.75 | 0.238449E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243588E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.261701E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339080E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467212E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3170209.67 | 0.355506E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194519E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246384.87 | 0.467212E+09 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205889E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281487E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196631E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219218E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.479241E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 564473.37 | 0.362403E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246390.72 | 0.307322E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 359353.43 | 0.244563E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.261828E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274193E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342803E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467986E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3170217.51 | 0.364356E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196631E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246390.72 | 0.479241E+09 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203895E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.277416E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194315E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208981E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467624E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 564473.44 | 0.360109E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246389.67 | 0.305677E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 359353.88 | 0.240596E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249559E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262153E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339057E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.467212E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3170216.99 | 0.357659E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194315E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2246389.67 | 0.467624E+09 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122984E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167331E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117274E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123721E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.280765E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 340475.89 | 0.220015E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.63 | 0.186743E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 216753.28 | 0.147347E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149107E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157577E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204513E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281810E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1912193.80 | 0.215919E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117274E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.63 | 0.281810E+09 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122984E+09 |
| February | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167331E+09 |
| March | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117274E+09 |
| April | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124003E+09 |
| May | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281097E+09 |
| June | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 340475.93 | 0.220142E+09 |
| July | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.73 | 0.186950E+09 |
| August | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 216753.30 | 0.147427E+09 |
| September | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149523E+09 |
| October | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157644E+09 |
| November | 0.421173E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204513E+09 |
| December | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281810E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1912193.95 | 0.216070E+10 |
| Minimum of Months | 0.393095E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117274E+09 |
| Maximum of Months | 0.435212E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.73 | 0.281810E+09 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124760E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170526E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119199E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131998E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.290463E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 340475.72 | 0.222357E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.22 | 0.188545E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 216752.73 | 0.150398E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160735E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166913E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207701E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.282583E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1912192.68 | 0.221618E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119199E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.22 | 0.290463E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124783E+09 |
| February | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170526E+09 |
| March | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119217E+09 |
| April | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132159E+09 |
| May | 0.424935E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.290614E+09 |
| June | 0.406980E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 340475.74 | 0.222341E+09 |
| July | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.35 | 0.188599E+09 |
| August | 0.418950E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 216752.76 | 0.150401E+09 |
| September | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160796E+09 |
| October | 0.430920E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166935E+09 |
| November | 0.418950E+09 | 0.119524E+09 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207721E+09 |
| December | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.282595E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.145421E+10 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1912192.85 | 0.221669E+10 |
| Minimum of Months | 0.389025E+09 | 0.111556E+09 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119217E+09 |
| Maximum of Months | 0.436905E+09 | 0.123508E+09 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1354964.35 | 0.290614E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34636984.14 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47603386.03 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34029294.74 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39017437.47 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88096542.80 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.73 | 71057475.28 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90465.13 | 62329633.73 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2475.47 | 50415922.61 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49740313.88 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47815415.80 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58011600.00 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77645410.36 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92950.33 | 0.660399E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34029294.74 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90465.13 | 88096542.80 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339747E+10 |
| February | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300213E+10 |
| March | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.296028E+10 |
| April | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240777E+10 |
| May | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19633.03 | 0.244320E+10 |
| June | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1656822.69 | 0.193795E+10 |
| July | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10463300.01 | 0.179533E+10 |
| August | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 909500.01 | 0.169749E+10 |
| September | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200165E+10 |
| October | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256191E+10 |
| November | 0.704201E+09 | 0.960667E+09 | 0.290107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.290851E+10 |
| December | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339663E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.352964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13049255.73 | 0.305103E+11 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.270767E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169749E+10 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.299778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10463300.01 | 0.339747E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28429409.12 |
| February | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38987966.48 |
| March | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27796244.60 |
| April | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32287542.63 |
| May | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74609271.16 |
| June | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3844.09 | 59102609.32 |
| July | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101111.20 | 51174531.64 |
| August | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5594.66 | 41669231.61 |
| September | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43271670.92 |
| October | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40956814.86 |
| November | 0.704201E+09 | 0.960667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48119514.15 |
| December | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64000924.17 |
| Annual Sum or Average | 0.856778E+10 | 0.116881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110549.95 | 0.550406E+09 |
| Minimum of Months | 0.657255E+09 | 0.896622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27796244.60 |
| Maximum of Months | 0.727675E+09 | 0.992689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101111.20 | 74609271.16 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 229.85 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 213.06 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 256.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 184.77 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 298.67 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 | 13-JUN-15:30 | 212.25 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.44 | 22-JUL-15:00 | 200.73 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.59 | 14-AUG-16:50 | 163.72 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 193.81 | 29-SEP-06:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 227.13 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 302.55 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 395.55 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.72 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 32.44 | 395.55 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 229.85 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 213.06 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 256.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 184.77 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.71 | 22-MAY-15:00 | 298.67 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 | 13-JUN-15:30 | 206.08 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.44 | 22-JUL-15:00 | 200.73 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.59 | 14-AUG-16:50 | 163.68 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 176.26 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 222.27 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 302.55 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 395.55 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.68 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 32.44 | 395.55 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 582.92 | 03-JAN-08:09 | 588.62 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 229.85 | 10-JAN-16:00 |
| February | 451.21 | 01-FEB-08:09 | 582.92 | 01-FEB-08:09 | 588.62 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 197.50 | 01-FEB-16:00 |
| March | 451.21 | 01-MAR-08:09 | 582.92 | 01-MAR-08:09 | 588.62 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 241.23 | 31-MAR-08:00 |
| April | 451.21 | 03-APR-07:10 | 582.92 | 03-APR-07:10 | 588.62 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 186.71 | 23-APR-22:00 |
| May | 451.21 | 01-MAY-07:10 | 582.92 | 01-MAY-07:10 | 588.62 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 311.36 | 05-MAY-09:00 |
| June | 451.21 | 01-JUN-07:10 | 582.92 | 01-JUN-07:10 | 588.62 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 | 13-JUN-15:30 | 229.46 | 05-JUN-14:00 |
| July | 451.21 | 03-JUL-07:10 | 582.92 | 03-JUL-07:10 | 588.62 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.71 | 21-JUL-15:00 | 207.80 | 30-JUL-19:00 |
| August | 451.21 | 01-AUG-07:10 | 582.92 | 01-AUG-07:10 | 588.62 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.29 | 14-AUG-16:00 | 196.94 | 22-AUG-18:00 |
| September | 451.21 | 01-SEP-07:10 | 582.92 | 01-SEP-07:10 | 588.62 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 207.42 | 29-SEP-17:00 |
| October | 451.21 | 02-OCT-07:10 | 582.92 | 02-OCT-07:10 | 588.62 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 232.59 | 01-OCT-24:00 |
| November | 451.21 | 01-NOV-07:10 | 582.92 | 01-NOV-07:10 | 588.62 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 263.18 | 15-NOV-07:00 |
| December | 451.21 | 01-DEC-08:09 | 582.92 | 01-DEC-08:09 | 588.62 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 321.00 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 186.71 | |||||
| Maximum of Months | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 | 321.00 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 229.85 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 213.06 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 256.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 184.77 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 | 22-MAY-15:00 | 298.67 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 | 13-JUN-15:30 | 194.65 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.44 | 22-JUL-15:00 | 193.61 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.59 | 14-AUG-16:50 | 159.60 | 22-AUG-18:40 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 184.36 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 222.27 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 302.55 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 395.55 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.60 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 32.44 | 395.55 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 138.64 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 128.51 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 154.92 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 | 30-APR-15:00 | 111.45 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.39 | 22-MAY-15:00 | 180.15 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.21 | 13-JUN-15:30 | 122.70 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 22-JUL-15:00 | 120.77 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 14-AUG-16:50 | 98.48 | 22-AUG-18:30 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 113.14 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 134.07 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 182.49 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 238.59 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.48 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 238.59 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 138.64 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 128.51 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 154.92 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.61 | 30-APR-15:00 | 111.45 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.35 | 22-MAY-15:00 | 180.15 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.21 | 13-JUN-15:30 | 122.39 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 22-JUL-15:00 | 120.47 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 14-AUG-16:50 | 98.48 | 22-AUG-18:30 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 113.68 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 134.07 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 182.49 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 238.59 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.48 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 238.59 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 138.64 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 128.51 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 154.92 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 118.36 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 180.15 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.21 | 13-JUN-15:30 | 127.68 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 22-JUL-15:00 | 121.07 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 14-AUG-16:50 | 98.75 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 122.95 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 142.33 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 182.49 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 238.59 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.75 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 238.59 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 138.64 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 128.51 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 154.92 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 118.85 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 180.15 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.21 | 13-JUN-15:30 | 128.10 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 22-JUL-15:00 | 121.07 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 14-AUG-16:50 | 98.75 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 123.53 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 142.57 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 182.49 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 238.59 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.75 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 19.57 | 238.59 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 331.21 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 306.58 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 369.50 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 300.19 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 439.36 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.19 | 13-JUN-15:30 | 335.55 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 22-JUL-15:00 | 288.98 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.67 | 14-AUG-16:50 | 235.82 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 291.18 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 334.34 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 435.44 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 569.14 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.82 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 569.14 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 330.58 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 306.58 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 369.50 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 291.61 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 432.52 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.19 | 13-JUN-15:30 | 329.14 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 22-JUL-15:00 | 288.98 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.67 | 14-AUG-16:50 | 235.82 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 278.25 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 319.95 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 435.44 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 569.14 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.82 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 569.14 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 330.58 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 306.58 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 369.50 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 300.91 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 449.28 | 05-MAY-09:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.19 | 13-JUN-15:30 | 333.95 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 22-JUL-15:00 | 288.98 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.67 | 14-AUG-16:50 | 235.82 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 294.96 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 333.20 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 435.44 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 569.14 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.82 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 569.14 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 330.58 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 306.58 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 369.50 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 293.61 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 439.99 | 05-MAY-09:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.19 | 13-JUN-15:30 | 327.57 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 22-JUL-15:00 | 288.98 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.67 | 14-AUG-16:50 | 235.76 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 288.33 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 319.95 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 435.44 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 569.14 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.76 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 46.44 | 569.14 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 199.40 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 184.92 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 222.87 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 184.82 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 275.81 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.81 | 13-JUN-15:30 | 202.87 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 22-JUL-15:00 | 174.31 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.28 | 14-AUG-16:50 | 142.24 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 176.70 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 195.39 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 262.65 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 343.29 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 343.29 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 199.40 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 184.92 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 222.87 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 185.09 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 275.47 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.81 | 13-JUN-15:30 | 202.88 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 22-JUL-15:00 | 174.31 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.28 | 14-AUG-16:50 | 142.24 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 177.28 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 195.48 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 262.65 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 343.29 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 343.29 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 203.74 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 184.92 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 222.87 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 190.11 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 280.47 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.81 | 13-JUN-15:30 | 202.85 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 22-JUL-15:00 | 174.31 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.28 | 14-AUG-16:50 | 142.24 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 177.91 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 208.48 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 263.43 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 343.29 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 343.29 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 203.68 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 184.92 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 222.87 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 190.16 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 280.21 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.81 | 13-JUN-15:30 | 202.85 | 05-JUN-14:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 22-JUL-15:00 | 174.31 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.28 | 14-AUG-16:50 | 142.24 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 177.91 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 208.44 | 01-OCT-24:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 263.53 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 343.29 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.24 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 28.01 | 343.29 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 438.01 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 406.61 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 489.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 352.83 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 569.99 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.53 | 13-JUN-15:40 | 434.52 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 22-JUL-15:00 | 383.64 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.87 | 14-AUG-16:50 | 313.36 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 356.79 | 29-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 424.61 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 577.74 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 754.71 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 313.36 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 754.71 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 438.01 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 406.61 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 489.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 352.83 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 569.99 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.53 | 13-JUN-15:40 | 434.52 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 22-JUL-15:00 | 383.64 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.87 | 14-AUG-16:50 | 313.36 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 342.64 | 29-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 424.61 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 577.74 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 754.71 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 313.36 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 754.71 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 438.01 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 406.61 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 489.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 352.83 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 569.99 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.53 | 13-JUN-15:40 | 422.23 | 06-JUN-12:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 22-JUL-15:00 | 383.64 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.87 | 14-AUG-16:50 | 313.26 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 356.79 | 29-SEP-17:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 424.61 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 577.74 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 754.71 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 313.26 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 754.71 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 438.01 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 406.61 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 489.84 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 352.83 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 569.99 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.53 | 13-JUN-15:40 | 410.02 | 06-JUN-12:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 22-JUL-15:00 | 383.64 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.87 | 14-AUG-16:50 | 296.06 | 22-AUG-18:40 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 334.12 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 424.61 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 577.74 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 754.71 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 296.06 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 60.94 | 754.71 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 264.20 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 245.25 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 295.46 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 212.82 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 343.81 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.44 | 13-JUN-15:40 | 258.99 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 22-JUL-15:00 | 231.40 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 14-AUG-16:50 | 187.40 | 22-AUG-18:30 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 203.81 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 256.11 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 348.48 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 455.22 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.40 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 455.22 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 264.20 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 245.25 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 295.46 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 212.82 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 343.81 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.44 | 13-JUN-15:40 | 257.57 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 22-JUL-15:00 | 231.40 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 14-AUG-16:50 | 186.68 | 22-AUG-18:40 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 205.83 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 256.11 | 20-OCT-22:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 348.48 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 455.22 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 186.68 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 455.22 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 267.19 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 245.25 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 295.46 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 212.82 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 343.81 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.44 | 13-JUN-15:40 | 259.53 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 22-JUL-15:00 | 231.40 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 14-AUG-16:50 | 189.01 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 221.64 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 262.81 | 31-OCT-13:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 348.48 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 455.22 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 455.22 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 138.88 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 266.96 | 10-JAN-16:00 |
| February | 237.50 | 01-FEB-00:10 | 138.88 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 245.25 | 01-FEB-21:00 |
| March | 237.50 | 01-MAR-00:10 | 138.88 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 295.46 | 31-MAR-08:00 |
| April | 237.50 | 01-APR-00:10 | 138.88 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 212.82 | 23-APR-22:00 |
| May | 237.50 | 01-MAY-00:10 | 138.88 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 343.81 | 04-MAY-23:00 |
| June | 237.50 | 01-JUN-00:10 | 138.88 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.44 | 13-JUN-15:40 | 258.51 | 05-JUN-19:00 |
| July | 237.50 | 01-JUL-00:10 | 138.88 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 22-JUL-15:00 | 231.40 | 30-JUL-19:00 |
| August | 237.50 | 01-AUG-00:10 | 138.88 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 14-AUG-16:50 | 189.01 | 22-AUG-18:20 |
| September | 237.50 | 01-SEP-00:10 | 138.88 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 222.46 | 06-SEP-20:00 |
| October | 237.50 | 01-OCT-00:10 | 138.88 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 263.54 | 31-OCT-13:00 |
| November | 237.50 | 01-NOV-00:10 | 138.88 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 348.48 | 15-NOV-07:00 |
| December | 237.50 | 01-DEC-00:10 | 138.88 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 455.22 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.01 | |||||
| Maximum of Months | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 36.76 | 455.22 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 75.28 | 10-JAN-16:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 68.46 | 01-FEB-21:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 82.12 | 31-MAR-08:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 64.70 | 23-APR-22:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 99.14 | 04-MAY-23:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.02 | 13-JUN-17:00 | 79.84 | 05-JUN-19:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.21 | 22-JUL-15:00 | 75.81 | 30-JUL-19:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 | 14-AUG-17:00 | 63.25 | 22-AUG-18:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 66.64 | 06-SEP-20:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 74.35 | 20-OCT-22:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 99.17 | 15-NOV-07:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 127.40 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.25 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.21 | 127.40 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 208.40 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13442.05 | 10-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 208.40 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 13405.47 | 17-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 208.40 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 11521.20 | 08-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 208.40 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 11539.29 | 08-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 208.40 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.87 | 22-MAY-15:00 | 10034.83 | 06-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 208.40 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 443.11 | 13-JUN-16:03 | 8177.27 | 08-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 208.40 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1005.93 | 22-JUL-16:05 | 7496.83 | 05-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 208.40 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 289.57 | 14-AUG-17:00 | 8467.79 | 24-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 208.40 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 10013.26 | 21-SEP-06:01 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 208.40 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 11001.61 | 04-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 208.40 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 11950.49 | 29-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 208.40 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 12218.63 | 27-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7496.83 | |||||
| Maximum of Months | 397.10 | 370.63 | 208.40 | 0.00 | 0.00 | 0.00 | 0.00 | 1005.93 | 13442.05 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 370.63 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 59.71 | 10-JAN-16:00 |
| February | 397.10 | 01-FEB-00:10 | 370.63 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 56.10 | 01-FEB-21:00 |
| March | 397.10 | 01-MAR-00:10 | 370.63 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 68.06 | 31-MAR-08:00 |
| April | 397.10 | 01-APR-00:10 | 370.63 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 58.95 | 23-APR-22:00 |
| May | 397.10 | 01-MAY-00:10 | 370.63 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 87.80 | 04-MAY-23:00 |
| June | 397.10 | 01-JUN-00:10 | 370.63 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.08 | 13-JUN-17:00 | 64.52 | 05-JUN-14:00 |
| July | 397.10 | 01-JUL-00:10 | 370.63 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 | 22-JUL-15:00 | 58.59 | 30-JUL-19:00 |
| August | 397.10 | 01-AUG-00:10 | 370.63 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.02 | 14-AUG-17:00 | 50.14 | 22-AUG-18:00 |
| September | 397.10 | 01-SEP-00:10 | 370.63 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 56.61 | 06-SEP-20:00 |
| October | 397.10 | 01-OCT-00:10 | 370.63 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 64.56 | 01-OCT-24:00 |
| November | 397.10 | 01-NOV-00:10 | 370.63 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 82.57 | 15-NOV-07:00 |
| December | 397.10 | 01-DEC-00:10 | 370.63 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 103.05 | 02-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.14 | ||||
| Maximum of Months | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 | 103.05 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 516.61 | 21-JAN-17:01 | 2375.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 535.87 | 19-FEB-17:45 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.69 |
| March | 392.56 | 23-MAR-18:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.15 |
| April | 1340.18 | 30-APR-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 726.38 | 25-MAY-16:40 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.83 |
| June | 1459.64 | 13-JUN-17:20 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 12.91 | 0.00 |
| July | 1870.49 | 22-JUL-16:30 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 0.00 |
| August | 1693.80 | 14-AUG-16:14 | 0.00 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 16.17 | 0.00 |
| September | 1656.88 | 13-SEP-16:05 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.27 |
| October | 984.80 | 03-OCT-16:04 | 0.00 | 694.39 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.71 |
| November | 552.91 | 11-NOV-17:55 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 452.49 | 26-DEC-14:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 392.56 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1870.49 | 2375.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 77.15 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 136.64 | 19-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 227.23 | 27-FEB-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.43 |
| March | 338.11 | 20-MAR-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.42 |
| April | 481.27 | 30-APR-17:40 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 519.25 | 01-MAY-05:00 | 237.50 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.79 |
| June | 1096.64 | 13-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| July | 1495.59 | 22-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 14.91 | 0.00 |
| August | 1052.59 | 14-AUG-17:05 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 16.49 | 0.00 |
| September | 735.80 | 13-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.56 |
| October | 491.19 | 05-OCT-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.01 |
| November | 377.98 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.87 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.14 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 71.25 | 8.68 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1495.59 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 16.49 | 181.79 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 980.93 | 10-JAN-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.64 |
| February | 834.52 | 17-FEB-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 666.66 | 13-MAR-07:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1177.46 | 28-APR-14:40 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.23 |
| May | 2615.72 | 23-MAY-08:63 | 1353.62 | 1748.75 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.07 |
| June | 5457.80 | 21-JUN-08:62 | 2256.03 | 2914.58 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.68 |
| July | 5398.84 | 12-JUL-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.55 |
| August | 5525.91 | 29-AUG-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.39 |
| September | 5598.24 | 26-SEP-08:62 | 1804.82 | 2331.66 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.09 |
| October | 1305.80 | 03-OCT-14:30 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.63 |
| November | 754.52 | 29-NOV-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.36 |
| December | 770.65 | 27-DEC-08:03 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.55 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 666.66 | 451.21 | 582.92 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5598.24 | 4512.06 | 5829.16 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 33.25 | 29-JAN-17:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 01-FEB-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.34 |
| March | 337.82 | 20-MAR-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.36 |
| April | 427.81 | 29-APR-05:50 | 237.50 | 60.76 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 519.71 | 01-MAY-05:00 | 237.50 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.95 |
| June | 721.99 | 25-JUN-16:10 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 1.14 | 0.00 |
| July | 1153.54 | 22-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 14.91 | 0.00 |
| August | 786.35 | 14-AUG-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 16.49 | 0.00 |
| September | 563.65 | 13-SEP-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.92 |
| October | 488.12 | 05-OCT-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.68 |
| November | 377.71 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.85 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.14 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 71.25 | 8.68 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1153.54 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 16.49 | 181.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 222.79 | 29-JAN-17:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 164.06 | 27-FEB-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.48 |
| March | 338.16 | 20-MAR-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.08 |
| April | 441.41 | 25-APR-21:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 527.13 | 01-MAY-05:00 | 237.50 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.23 |
| June | 582.12 | 13-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
| July | 959.14 | 22-JUL-18:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 11.63 | 0.00 |
| August | 673.31 | 14-AUG-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 0.00 |
| September | 514.57 | 20-SEP-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 542.91 | 04-OCT-01:50 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 379.03 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.04 |
| December | 132.32 | 05-DEC-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 132.32 | 71.25 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 959.14 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 11.63 | 111.23 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 222.28 | 29-JAN-17:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 161.83 | 07-FEB-17:02 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 338.16 | 20-MAR-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.08 |
| April | 448.86 | 25-APR-21:03 | 712.50 | 156.25 | 1253.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 527.56 | 01-MAY-05:00 | 237.50 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.32 |
| June | 581.47 | 25-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 951.81 | 22-JUL-18:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 11.63 | 0.00 |
| August | 670.20 | 14-AUG-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 0.00 |
| September | 515.46 | 20-SEP-24:00 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 542.90 | 04-OCT-01:50 | 237.50 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 379.00 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.04 |
| December | 131.89 | 05-DEC-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 131.89 | 71.25 | 8.68 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 951.81 | 1111.50 | 781.19 | 5297.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11.63 | 111.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 634.90 | 11-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.55 |
| February | 579.50 | 19-FEB-18:25 | 475.00 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.71 |
| March | 432.05 | 12-MAR-16:17 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1007.24 | 30-APR-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 577.03 | 03-MAY-05:00 | 237.50 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 939.00 | 13-JUN-16:05 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 12.95 | 0.00 |
| July | 1384.76 | 22-JUL-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 16.39 | 0.00 |
| August | 1310.49 | 20-AUG-16:05 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.94 |
| September | 1354.34 | 25-SEP-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.06 |
| October | 955.24 | 01-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.44 |
| November | 583.55 | 11-NOV-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 501.02 | 26-DEC-15:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.27 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 432.05 | 0.00 | 17.36 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1384.76 | 950.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 16.39 | 48.55 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 584.36 | 11-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.55 |
| February | 534.66 | 19-FEB-17:45 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.51 |
| March | 400.14 | 10-MAR-16:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.23 |
| April | 1070.21 | 30-APR-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 579.79 | 03-MAY-05:00 | 237.50 | 56.42 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 981.38 | 26-JUN-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.21 |
| July | 1468.64 | 22-JUL-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 16.39 | 0.00 |
| August | 1384.92 | 20-AUG-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.94 |
| September | 1400.04 | 25-SEP-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.06 |
| October | 984.45 | 01-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.44 |
| November | 582.39 | 11-NOV-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 484.24 | 26-DEC-15:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.24 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 400.14 | 0.00 | 17.36 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1468.64 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 16.39 | 48.55 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 736.89 | 11-JAN-17:01 | 0.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.37 |
| February | 734.58 | 17-FEB-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.16 |
| March | 559.74 | 10-MAR-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 2558.77 | 30-APR-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.02 |
| May | 2035.37 | 22-MAY-16:10 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.55 |
| June | 2422.84 | 13-JUN-17:10 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.19 | 0.00 |
| July | 2556.38 | 22-JUL-16:20 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 38.90 | 0.00 |
| August | 2463.30 | 14-AUG-16:10 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 22.49 | 0.00 |
| September | 2316.26 | 12-SEP-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.94 |
| October | 1687.49 | 03-OCT-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.39 |
| November | 605.72 | 11-NOV-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 597.49 | 18-DEC-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 559.74 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2558.77 | 475.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 38.90 | 123.16 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 475.90 | 19-JAN-17:35 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 517.41 | 24-FEB-17:25 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.12 |
| March | 501.14 | 23-MAR-21:25 | 475.00 | 104.17 | 835.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1717.92 | 30-APR-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| May | 1434.55 | 22-MAY-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.55 |
| June | 2160.76 | 13-JUN-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 13.51 | 0.00 |
| July | 2147.72 | 22-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 21.35 | 0.00 |
| August | 1790.67 | 14-AUG-17:05 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 23.54 | 0.00 |
| September | 1465.63 | 13-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.15 |
| October | 578.78 | 07-OCT-04:00 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 462.33 | 10-NOV-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 217.58 | 21-DEC-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 217.58 | 123.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2160.76 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 23.54 | 59.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 723.88 | 11-JAN-14:00 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.42 |
| February | 693.36 | 17-FEB-20:20 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.86 |
| March | 557.51 | 10-MAR-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 2213.62 | 30-APR-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.47 |
| May | 1704.58 | 22-MAY-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.82 |
| June | 1952.63 | 13-JUN-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 5.27 | 0.00 |
| July | 2281.51 | 22-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 43.26 | 0.00 |
| August | 2096.75 | 14-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 | 0.00 |
| September | 2066.14 | 25-SEP-13:10 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.15 |
| October | 1452.29 | 03-OCT-13:40 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.35 |
| November | 604.12 | 11-NOV-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 591.07 | 18-DEC-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 557.51 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2281.51 | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 43.26 | 119.42 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 369.77 | 19-JAN-17:08 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 392.90 | 22-FEB-18:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 463.27 | 12-MAR-17:15 | 1239.75 | 703.09 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1192.28 | 30-APR-17:20 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| May | 1126.11 | 23-MAY-10:10 | 59.38 | 17.36 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.47 |
| June | 1507.34 | 13-JUN-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 13.51 | 0.00 |
| July | 1617.58 | 22-JUL-18:30 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 21.35 | 0.00 |
| August | 1306.73 | 14-AUG-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.54 | 0.00 |
| September | 1046.17 | 13-SEP-16:20 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 |
| October | 579.03 | 07-OCT-04:00 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 428.19 | 10-NOV-17:08 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.36 |
| December | 206.44 | 20-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 206.44 | 59.38 | 17.36 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1617.58 | 1239.75 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 23.54 | 31.47 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 528.28 | 19-JAN-18:35 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.92 |
| February | 487.69 | 27-FEB-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 540.89 | 21-MAR-21:50 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 984.87 | 30-APR-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.06 |
| May | 851.19 | 24-MAY-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.68 |
| June | 1232.36 | 13-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.69 |
| July | 1304.86 | 22-JUL-18:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 16.66 | 0.00 |
| August | 1063.19 | 14-AUG-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 14.20 | 0.00 |
| September | 871.59 | 13-SEP-17:00 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.97 |
| October | 595.80 | 07-OCT-04:00 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 525.54 | 10-NOV-22:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 397.66 | 20-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 397.66 | 123.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1304.86 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 16.66 | 44.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 528.00 | 19-JAN-18:35 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.90 |
| February | 487.04 | 27-FEB-19:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 540.57 | 21-MAR-21:50 | 237.50 | 52.08 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 980.58 | 30-APR-18:50 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.06 |
| May | 838.29 | 24-MAY-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.68 |
| June | 1221.61 | 13-JUN-18:00 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.69 |
| July | 1295.90 | 22-JUL-18:40 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 16.66 | 0.00 |
| August | 1056.16 | 14-AUG-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 14.20 | 0.00 |
| September | 866.72 | 13-SEP-16:50 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 |
| October | 596.14 | 07-OCT-04:00 | 237.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 522.61 | 10-NOV-22:00 | 237.50 | 95.48 | 500.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 399.31 | 20-DEC-20:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 399.31 | 123.50 | 26.04 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1295.90 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 16.66 | 44.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 800.67 | 11-JAN-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 750.16 | 17-FEB-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.81 |
| March | 613.15 | 02-MAR-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1889.38 | 30-APR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.81 |
| May | 1388.40 | 22-MAY-15:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 |
| June | 1544.19 | 13-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 9.29 | 0.00 |
| July | 1806.48 | 22-JUL-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 26.09 | 0.00 |
| August | 1761.56 | 14-AUG-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 2.76 | 0.00 |
| September | 1907.87 | 27-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.21 |
| October | 1526.70 | 03-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.60 |
| November | 672.68 | 28-NOV-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 709.81 | 26-DEC-20:00 | 237.50 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 613.15 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1907.87 | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 26.09 | 75.81 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 800.57 | 11-JAN-19:00 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 749.73 | 17-FEB-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.77 |
| March | 612.94 | 02-MAR-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 1894.61 | 30-APR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.81 |
| May | 1391.93 | 22-MAY-14:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.31 |
| June | 1548.39 | 13-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 9.29 | 0.00 |
| July | 1812.64 | 22-JUL-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 26.09 | 0.00 |
| August | 1765.40 | 14-AUG-14:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1.80 | 0.00 |
| September | 1912.00 | 27-SEP-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.21 |
| October | 1530.24 | 03-OCT-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.60 |
| November | 672.90 | 28-NOV-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 709.94 | 26-DEC-20:00 | 237.50 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 612.94 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1912.00 | 237.50 | 138.88 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 26.09 | 75.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 773.12 | 15-JAN-15:00 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.91 |
| February | 1168.41 | 27-FEB-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 526.80 | 10-MAR-20:20 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 3321.31 | 30-APR-16:10 | 237.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.06 |
| May | 2792.06 | 22-MAY-16:10 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.41 |
| June | 3263.08 | 13-JUN-17:10 | 237.50 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.19 | 0.00 |
| July | 3495.69 | 22-JUL-16:10 | 475.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 51.05 | 0.00 |
| August | 3186.51 | 14-AUG-16:05 | 0.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 29.19 | 0.00 |
| September | 2861.08 | 12-SEP-15:30 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.61 |
| October | 2045.35 | 07-OCT-15:20 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.25 |
| November | 659.29 | 11-NOV-14:20 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 157.48 |
| December | 568.25 | 26-DEC-16:20 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.62 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 526.80 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3495.69 | 475.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 51.05 | 157.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 423.03 | 19-JAN-16:30 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 485.10 | 19-FEB-17:12 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.98 |
| March | 460.82 | 23-MAR-19:10 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.08 |
| April | 2251.17 | 30-APR-17:20 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 2164.95 | 22-MAY-16:05 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.41 |
| June | 2941.59 | 13-JUN-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 17.38 | 0.00 |
| July | 2886.63 | 22-JUL-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 28.05 | 0.00 |
| August | 2335.42 | 14-AUG-16:40 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 | 0.00 |
| September | 1785.31 | 13-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.19 |
| October | 501.27 | 03-OCT-19:00 | 206.62 | 138.88 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 380.37 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.78 |
| December | 1.83 | 02-DEC-13:40 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1.83 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2941.59 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 | 83.08 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 725.35 | 11-JAN-14:10 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.11 |
| February | 942.41 | 04-FEB-14:20 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.95 |
| March | 541.83 | 25-MAR-12:00 | 118.75 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 2853.46 | 30-APR-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.94 |
| May | 2370.52 | 22-MAY-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.44 |
| June | 2710.26 | 13-JUN-13:30 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 6.46 | 0.00 |
| July | 3152.74 | 22-JUL-13:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 56.66 | 0.00 |
| August | 2697.75 | 14-AUG-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 | 0.00 |
| September | 2516.55 | 12-SEP-12:40 | 0.00 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.98 |
| October | 1696.65 | 07-OCT-13:40 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.95 |
| November | 618.87 | 11-NOV-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.27 |
| December | 559.68 | 26-DEC-16:10 | 0.00 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.14 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 541.83 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 3152.74 | 118.75 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 56.66 | 169.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 262.48 | 23-JAN-13:00 | 59.38 | 17.36 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 248.53 | 27-FEB-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.18 |
| March | 390.35 | 30-MAR-17:25 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 218.64 |
| April | 1507.11 | 30-APR-16:20 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.12 |
| May | 1506.73 | 22-MAY-15:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.46 |
| June | 1991.86 | 13-JUN-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 39.43 | 0.00 |
| July | 2164.17 | 22-JUL-16:20 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 51.05 | 0.00 |
| August | 1624.63 | 14-AUG-16:14 | 617.50 | 434.00 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 29.95 | 0.00 |
| September | 1185.88 | 13-SEP-16:05 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.63 |
| October | 486.44 | 05-OCT-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.88 |
| November | 377.16 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.40 |
| December | 0.00 | 01-DEC-00:10 | 237.50 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.02 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 59.38 | 8.68 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2164.17 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 51.05 | 218.64 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 271.20 | 19-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 401.95 | 27-FEB-17:17 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.33 |
| March | 413.08 | 30-MAR-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.58 |
| April | 1211.89 | 30-APR-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
| May | 1191.92 | 22-MAY-16:05 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.52 |
| June | 1692.08 | 13-JUN-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 10.48 | 0.00 |
| July | 1769.28 | 22-JUL-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 | 0.00 |
| August | 1334.62 | 14-AUG-17:20 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 18.53 | 0.00 |
| September | 985.63 | 13-SEP-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.75 |
| October | 497.10 | 05-OCT-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.20 |
| November | 378.84 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.71 |
| December | 106.30 | 02-DEC-13:40 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 106.30 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1769.28 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 | 169.58 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 263.30 | 19-JAN-16:10 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 370.52 | 27-FEB-17:02 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.55 |
| March | 412.95 | 30-MAR-17:50 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.53 |
| April | 1205.37 | 30-APR-16:30 | 123.50 | 86.80 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
| May | 1187.47 | 22-MAY-16:10 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.52 |
| June | 1668.89 | 13-JUN-17:30 | 206.62 | 117.18 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 10.48 | 0.00 |
| July | 1755.44 | 22-JUL-16:20 | 247.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 | 0.00 |
| August | 1319.71 | 14-AUG-17:10 | 413.25 | 234.36 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 18.53 | 0.00 |
| September | 977.68 | 13-SEP-16:15 | 494.00 | 347.20 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.19 |
| October | 495.89 | 05-OCT-20:00 | 206.62 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.05 |
| November | 378.68 | 10-NOV-16:40 | 71.25 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.69 |
| December | 106.87 | 02-DEC-13:40 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 106.87 | 59.38 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1755.44 | 1235.00 | 867.99 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 | 169.53 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 831.26 | 15-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.25 |
| February | 1133.81 | 04-FEB-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.27 |
| March | 549.26 | 10-MAR-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 2489.22 | 30-APR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.28 |
| May | 1985.89 | 22-MAY-14:40 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 |
| June | 2268.62 | 13-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 11.89 | 0.00 |
| July | 2630.72 | 22-JUL-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 34.16 | 0.00 |
| August | 2341.42 | 14-AUG-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 3.35 | 0.00 |
| September | 2268.17 | 11-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.62 |
| October | 1582.66 | 07-OCT-15:10 | 237.50 | 60.76 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.25 |
| November | 783.14 | 11-NOV-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.50 |
| December | 601.59 | 18-DEC-17:45 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.37 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 549.26 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2630.72 | 237.50 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 34.16 | 101.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 841.29 | 15-JAN-13:50 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.25 |
| February | 1141.09 | 04-FEB-14:30 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.27 |
| March | 548.67 | 10-MAR-21:00 | 237.50 | 138.88 | 523.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 2500.30 | 30-APR-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.28 |
| May | 1997.56 | 22-MAY-14:20 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.63 |
| June | 2274.95 | 13-JUN-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 11.89 | 0.00 |
| July | 2639.51 | 22-JUL-13:50 | 118.75 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 34.16 | 0.00 |
| August | 2348.38 | 14-AUG-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 3.35 | 0.00 |
| September | 2277.76 | 11-SEP-14:10 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.62 |
| October | 1588.19 | 07-OCT-14:30 | 0.00 | 30.38 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.67 |
| November | 798.06 | 11-NOV-13:40 | 118.75 | 17.36 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.50 |
| December | 601.45 | 18-DEC-17:45 | 0.00 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.35 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 548.67 | 0.00 | 17.36 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2639.51 | 237.50 | 173.60 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 34.16 | 101.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.59 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.87 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.33 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.55 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.01 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.84 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.61 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.16 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.81 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.02 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.78 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.93 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.18 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.41 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.14 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.34 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.66 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.99 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.30 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.79 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.57 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 56.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.82 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.81 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.01 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.19 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.01 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.82 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.80 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.88 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.38 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.08 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 370.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.01 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.101366E+12 | 71299.45 | 12-JAN-18:40 | 0.535390E+11 | 54764.95 | 10-JAN-05:00 |
| February | 0.912461E+11 | 68490.16 | 08-FEB-18:40 | 0.449635E+11 | 48478.36 | 17-FEB-03:00 |
| March | 0.997936E+11 | 67223.56 | 28-MAR-18:40 | 0.374119E+11 | 35703.29 | 04-MAR-05:00 |
| April | 0.969210E+11 | 73204.53 | 30-APR-16:10 | 0.892819E+10 | 24416.57 | 01-APR-04:00 |
| May | 0.984688E+11 | 66009.75 | 22-MAY-16:10 | 0.554600E+10 | 17874.05 | 05-MAY-03:00 |
| June | 0.986634E+11 | 73193.79 | 12-JUN-17:30 | 0.393769E+09 | 9290.83 | 08-JUN-03:00 |
| July | 0.104780E+12 | 80097.91 | 22-JUL-17:30 | 0.127284E+09 | 3535.47 | 05-JUL-04:30 |
| August | 0.105062E+12 | 74294.33 | 14-AUG-17:40 | 16090110.84 | 1184.51 | 23-AUG-04:00 |
| September | 0.991995E+11 | 69044.93 | 24-SEP-17:40 | 0.870780E+09 | 6173.91 | 20-SEP-03:00 |
| October | 0.979798E+11 | 63709.87 | 09-OCT-17:40 | 0.134392E+11 | 22809.78 | 28-OCT-06:00 |
| November | 0.959961E+11 | 64535.43 | 04-NOV-17:10 | 0.367916E+11 | 44849.97 | 29-NOV-03:00 |
| December | 0.101433E+12 | 68738.87 | 30-DEC-18:00 | 0.685924E+11 | 52650.86 | 30-DEC-01:00 |
| Annual Sum or Average | 0.119091E+13 | 0.270620E+12 | ||||
| Minimum of Months | 0.912461E+11 | 63709.87 | 16090110.84 | 1184.51 | ||
| Maximum of Months | 0.105062E+12 | 80097.91 | 0.685924E+11 | 54764.95 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
| January | 0.840929E+10 | 0.545686E+10 | 0.389380E+11 | 0.00 | 0.632352E+10 | 0.00 | 0.00 | 3185226.51 | 0.00 | 0.00 | 0.00 | 0.422354E+11 | 0.00 |
| February | 0.760941E+10 | 0.449041E+10 | 0.351823E+11 | 0.00 | 0.559770E+10 | 0.00 | 0.00 | 12259644.18 | 0.00 | 0.00 | 0.00 | 0.383540E+11 | 0.00 |
| March | 0.845392E+10 | 0.437008E+10 | 0.389781E+11 | 0.00 | 0.575099E+10 | 0.00 | 0.00 | 293356.47 | 0.00 | 0.00 | 0.00 | 0.422403E+11 | 0.00 |
| April | 0.814762E+10 | 0.362136E+10 | 0.376905E+11 | 0.00 | 0.523437E+10 | 0.00 | 0.00 | 0.206207E+10 | 0.00 | 0.00 | 0.00 | 0.401650E+11 | 0.00 |
| May | 0.843904E+10 | 0.320880E+10 | 0.389647E+11 | 0.00 | 0.522656E+10 | 0.00 | 0.00 | 0.199876E+10 | 0.00 | 0.00 | 0.00 | 0.406309E+11 | 0.00 |
| June | 0.817737E+10 | 0.282107E+10 | 0.377173E+11 | 0.00 | 0.596138E+10 | 0.00 | 0.00 | 0.559646E+10 | 0.00 | 0.00 | 0.00 | 0.383899E+11 | 0.00 |
| July | 0.840929E+10 | 0.304072E+10 | 0.389380E+11 | 0.00 | 0.692905E+10 | 0.00 | 0.00 | 0.845282E+10 | 0.00 | 0.00 | 0.00 | 0.390106E+11 | 0.00 |
| August | 0.845392E+10 | 0.350485E+10 | 0.389781E+11 | 0.00 | 0.691149E+10 | 0.00 | 0.00 | 0.844991E+10 | 0.00 | 0.00 | 0.00 | 0.387640E+11 | 0.00 |
| September | 0.814762E+10 | 0.396516E+10 | 0.376905E+11 | 0.00 | 0.597186E+10 | 0.00 | 0.00 | 0.564179E+10 | 0.00 | 0.00 | 0.00 | 0.377825E+11 | 0.00 |
| October | 0.842417E+10 | 0.472152E+10 | 0.389514E+11 | 0.00 | 0.517020E+10 | 0.00 | 0.00 | 0.878264E+09 | 0.00 | 0.00 | 0.00 | 0.398343E+11 | 0.00 |
| November | 0.814762E+10 | 0.511497E+10 | 0.376905E+11 | 0.00 | 0.559924E+10 | 0.00 | 0.00 | 2346397.01 | 0.00 | 0.00 | 0.00 | 0.394414E+11 | 0.00 |
| December | 0.840929E+10 | 0.560393E+10 | 0.389380E+11 | 0.00 | 0.686286E+10 | 0.00 | 0.00 | 16823.19 | 0.00 | 0.00 | 0.00 | 0.416194E+11 | 0.00 |
| Annual Sum or Average | 0.992286E+11 | 0.499197E+11 | 0.458657E+12 | 0.00 | 0.715392E+11 | 0.00 | 0.00 | 0.330982E+11 | 0.00 | 0.00 | 0.00 | 0.478468E+12 | 0.00 |
| Minimum of Months | 0.760941E+10 | 0.282107E+10 | 0.351823E+11 | 0.00 | 0.517020E+10 | 0.00 | 0.00 | 16823.19 | 0.00 | 0.00 | 0.00 | 0.377825E+11 | 0.00 |
| Maximum of Months | 0.845392E+10 | 0.560393E+10 | 0.389781E+11 | 0.00 | 0.692905E+10 | 0.00 | 0.00 | 0.845282E+10 | 0.00 | 0.00 | 0.00 | 0.422403E+11 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.535390E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.449635E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.374119E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.892819E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.554600E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.393769E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.127284E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 16090110.84 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.870780E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.134392E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.367916E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.685924E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.270620E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 16090110.84 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.685924E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 5904.43 | 01-JAN-19:10 | 3183.33 | 01-JAN-00:10 | 22709.69 | 03-JAN-17:10 | 0.00 | 3616.29 | 10-JAN-05:00 | 0.00 | 0.00 | 01-JAN-00:10 |
| February | 5904.43 | 01-FEB-19:10 | 3183.33 | 01-FEB-00:10 | 22709.69 | 01-FEB-17:10 | 0.00 | 3390.75 | 17-FEB-03:00 | 0.00 | 0.00 | 01-FEB-00:10 |
| March | 5904.43 | 01-MAR-19:10 | 3183.33 | 01-MAR-00:10 | 22709.69 | 01-MAR-17:10 | 0.00 | 2933.14 | 04-MAR-05:00 | 0.00 | 0.00 | 01-MAR-00:10 |
| April | 5904.43 | 01-APR-18:10 | 3183.33 | 01-APR-00:10 | 22709.69 | 03-APR-16:10 | 0.00 | 5576.87 | 30-APR-16:10 | 0.00 | 0.00 | 01-APR-00:10 |
| May | 5904.43 | 01-MAY-18:10 | 3183.33 | 01-MAY-00:10 | 22709.69 | 01-MAY-16:10 | 0.00 | 4772.02 | 22-MAY-15:09 | 0.00 | 0.00 | 01-MAY-00:10 |
| June | 5904.43 | 01-JUN-18:10 | 3183.33 | 01-JUN-00:10 | 22709.69 | 01-JUN-16:10 | 0.00 | 6286.10 | 13-JUN-16:30 | 0.00 | 0.00 | 01-JUN-00:10 |
| July | 5904.43 | 01-JUL-18:10 | 3183.33 | 01-JUL-00:10 | 22709.69 | 03-JUL-16:10 | 0.00 | 6881.08 | 22-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
| August | 5904.43 | 01-AUG-18:10 | 3183.33 | 01-AUG-00:10 | 22709.69 | 01-AUG-16:10 | 0.00 | 6048.68 | 14-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
| September | 5904.43 | 01-SEP-18:10 | 3183.33 | 01-SEP-00:10 | 22709.69 | 01-SEP-16:10 | 0.00 | 5442.65 | 13-SEP-16:10 | 0.00 | 0.00 | 01-SEP-00:10 |
| October | 5904.43 | 01-OCT-18:10 | 3183.33 | 01-OCT-00:10 | 22709.69 | 02-OCT-16:10 | 0.00 | 3239.14 | 07-OCT-15:09 | 0.00 | 0.00 | 01-OCT-00:10 |
| November | 5904.43 | 01-NOV-18:10 | 3183.33 | 01-NOV-00:10 | 22709.69 | 01-NOV-16:10 | 0.00 | 3261.34 | 29-NOV-03:00 | 0.00 | 0.00 | 01-NOV-00:10 |
| December | 5904.43 | 01-DEC-19:10 | 3183.33 | 01-DEC-00:10 | 22709.69 | 01-DEC-17:10 | 0.00 | 3540.88 | 30-DEC-01:00 | 0.00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 2933.14 | 0.00 | 0.00 | |||||
| Maximum of Months | 5904.43 | 3183.33 | 22709.69 | 0.00 | 6881.08 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
| January | 363.42 | 15-JAN-13:39 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 37817.01 | 29-JAN-07:30 | 0.00 |
| February | 705.22 | 04-FEB-14:30 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 37826.41 | 05-FEB-07:19 | 0.00 |
| March | 53.08 | 25-MAR-11:00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 36643.05 | 29-MAR-07:00 | 0.00 |
| April | 12704.43 | 30-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 36535.37 | 12-APR-06:19 | 0.00 |
| May | 10534.65 | 22-MAY-15:09 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 32762.99 | 02-MAY-06:40 | 0.00 |
| June | 15836.39 | 13-JUN-16:49 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 32792.84 | 23-JUN-07:49 | 0.00 |
| July | 17957.41 | 22-JUL-16:10 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 31291.82 | 24-JUL-06:19 | 0.00 |
| August | 14860.65 | 14-AUG-15:39 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 31960.58 | 20-AUG-05:10 | 0.00 |
| September | 12842.77 | 13-SEP-15:20 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 31249.37 | 27-SEP-07:19 | 0.00 |
| October | 5106.60 | 07-OCT-15:09 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 32946.12 | 13-OCT-07:10 | 0.00 |
| November | 289.94 | 11-NOV-13:50 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 33598.11 | 08-NOV-07:00 | 0.00 |
| December | 10.09 | 18-DEC-13:00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 35635.32 | 31-DEC-07:10 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 10.09 | 0.00 | 0.00 | 0.00 | 31249.37 | 0.00 | |||
| Maximum of Months | 17957.41 | 0.00 | 0.00 | 0.00 | 37826.41 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 71299.45 | 12-JAN-18:40 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2847.62 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 68490.16 | 08-FEB-18:40 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 1926.18 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 67223.56 | 28-MAR-18:40 | 5904.43 | 20531.10 | 3183.33 | 0.00 | 1748.69 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 73204.53 | 30-APR-16:10 | 4289.87 | 22609.62 | 0.00 | 0.00 | 5576.87 | 0.00 | 0.00 | 12704.43 | 0.00 |
| May | 66009.75 | 22-MAY-16:10 | 4289.87 | 22709.69 | 0.00 | 0.00 | 4661.21 | 0.00 | 0.00 | 9834.06 | 0.00 |
| June | 73193.79 | 12-JUN-17:30 | 5231.74 | 22609.62 | 0.00 | 0.00 | 5613.31 | 0.00 | 0.00 | 13239.75 | 0.00 |
| July | 80097.91 | 22-JUL-17:30 | 5231.74 | 22609.62 | 0.00 | 0.00 | 6826.75 | 0.00 | 0.00 | 17843.60 | 0.00 |
| August | 74294.33 | 14-AUG-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 5873.65 | 0.00 | 0.00 | 14184.27 | 0.00 |
| September | 69044.93 | 24-SEP-17:40 | 5231.74 | 22609.62 | 0.00 | 0.00 | 3731.33 | 0.00 | 0.00 | 6811.70 | 0.00 |
| October | 63709.87 | 09-OCT-17:40 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 1669.19 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 64535.43 | 04-NOV-17:10 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 1750.43 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 68738.87 | 30-DEC-18:00 | 5231.74 | 22609.62 | 3183.33 | 0.00 | 2806.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 63709.87 | 4289.87 | 20531.10 | 0.00 | 0.00 | 1669.19 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 80097.91 | 5904.43 | 22709.69 | 3183.33 | 0.00 | 6826.75 | 0.00 | 0.00 | 17843.60 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 54764.95 | 10-JAN-05:00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 48478.36 | 17-FEB-03:00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 35703.29 | 04-MAR-05:00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 24416.57 | 01-APR-04:00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 17874.05 | 05-MAY-03:00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 9290.83 | 08-JUN-03:00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 3535.47 | 05-JUL-04:30 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 1184.51 | 23-AUG-04:00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 6173.91 | 20-SEP-03:00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 22809.78 | 28-OCT-06:00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 44849.97 | 29-NOV-03:00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 52650.86 | 30-DEC-01:00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 1184.51 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 54764.95 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.10 | 332.00 | 21.10 | 332.00 | 21.10 |
| February | 473.00 | 21.11 | 295.50 | 21.11 | 295.50 | 21.10 |
| March | 506.00 | 21.10 | 377.50 | 21.10 | 377.50 | 21.10 |
| April | 494.50 | 21.65 | 28.00 | 21.62 | 28.00 | 21.60 |
| May | 504.17 | 21.89 | 0.00 | 21.89 | 0.00 | 21.89 |
| June | 383.67 | 22.84 | 19.00 | 22.89 | 0.00 | 22.89 |
| July | 256.67 | 23.09 | 78.17 | 23.30 | 0.00 | 23.30 |
| August | 166.83 | 23.52 | 65.17 | 23.65 | 0.00 | 23.65 |
| September | 266.17 | 23.21 | 33.67 | 23.30 | 0.00 | 23.30 |
| October | 514.83 | 21.80 | 2.00 | 21.80 | 2.00 | 21.80 |
| November | 510.00 | 21.12 | 115.50 | 21.12 | 115.50 | 21.11 |
| December | 533.00 | 21.10 | 467.50 | 21.10 | 467.50 | 21.10 |
| Annual Sum or Average | 5141.83 | 21.72 | 1814.00 | 21.64 | 1618.00 | 21.54 |
| Minimum of Months | 166.83 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.52 | 467.50 | 23.65 | 467.50 | 23.65 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 619.83 | 21.10 | 619.83 | 21.10 |
| February | 672.00 | 21.10 | 609.50 | 21.10 | 609.50 | 21.10 |
| March | 744.00 | 21.10 | 637.50 | 21.10 | 637.50 | 21.10 |
| April | 720.00 | 21.31 | 209.50 | 21.27 | 209.50 | 21.23 |
| May | 744.00 | 21.55 | 4.00 | 21.55 | 4.00 | 21.54 |
| June | 630.33 | 22.64 | 10.50 | 22.67 | 0.00 | 22.67 |
| July | 435.17 | 23.05 | 37.33 | 23.12 | 0.00 | 23.12 |
| August | 504.67 | 23.37 | 7.17 | 23.38 | 0.00 | 23.38 |
| September | 688.50 | 22.71 | 0.00 | 22.71 | 0.00 | 22.71 |
| October | 744.00 | 21.24 | 18.67 | 21.24 | 18.67 | 21.23 |
| November | 720.00 | 21.10 | 353.00 | 21.10 | 353.00 | 21.10 |
| December | 744.00 | 21.10 | 713.00 | 21.10 | 713.00 | 21.10 |
| Annual Sum or Average | 8090.67 | 21.68 | 3220.00 | 21.53 | 3165.00 | 21.43 |
| Minimum of Months | 435.17 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.37 | 713.00 | 23.38 | 713.00 | 23.38 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 140.00 | 21.00 | 106.17 | 20.95 | 106.17 | 20.94 |
| February | 133.00 | 20.97 | 98.67 | 20.93 | 98.67 | 20.92 |
| March | 161.00 | 20.97 | 137.83 | 20.94 | 137.83 | 20.94 |
| April | 131.00 | 22.71 | 10.00 | 22.56 | 10.00 | 22.42 |
| May | 118.83 | 23.03 | 0.50 | 23.02 | 0.50 | 23.01 |
| June | 43.33 | 23.78 | 45.50 | 23.99 | 0.00 | 23.99 |
| July | 8.00 | 23.98 | 102.50 | 24.19 | 0.00 | 24.19 |
| August | 0.00 | 0.00 | 141.17 | 24.21 | 0.00 | 24.21 |
| September | 10.17 | 23.94 | 78.00 | 24.13 | 0.00 | 24.13 |
| October | 118.83 | 22.41 | 4.33 | 22.34 | 4.33 | 22.27 |
| November | 140.00 | 21.22 | 53.33 | 21.10 | 53.33 | 21.03 |
| December | 140.00 | 20.94 | 131.67 | 20.94 | 131.67 | 20.93 |
| Annual Sum or Average | 1144.17 | 21.72 | 909.67 | 21.94 | 542.50 | 21.72 |
| Minimum of Months | 0.00 | 0.00 | 0.50 | 20.93 | 0.00 | 20.92 |
| Maximum of Months | 161.00 | 23.98 | 141.17 | 24.21 | 137.83 | 24.21 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 627.83 | 21.10 | 627.83 | 21.10 |
| February | 672.00 | 21.10 | 610.83 | 21.10 | 610.83 | 21.10 |
| March | 744.00 | 21.10 | 647.67 | 21.10 | 647.67 | 21.10 |
| April | 720.00 | 21.35 | 166.00 | 21.30 | 166.00 | 21.27 |
| May | 744.00 | 21.55 | 3.50 | 21.55 | 3.50 | 21.55 |
| June | 624.67 | 22.61 | 8.33 | 22.62 | 0.00 | 22.62 |
| July | 448.00 | 23.19 | 28.33 | 23.24 | 0.00 | 23.24 |
| August | 426.67 | 23.40 | 8.67 | 23.41 | 0.00 | 23.41 |
| September | 670.67 | 22.86 | 0.00 | 22.86 | 0.00 | 22.86 |
| October | 744.00 | 21.25 | 18.00 | 21.25 | 18.00 | 21.25 |
| November | 720.00 | 21.10 | 355.67 | 21.10 | 355.67 | 21.10 |
| December | 744.00 | 21.10 | 710.67 | 21.10 | 710.67 | 21.10 |
| Annual Sum or Average | 8002.00 | 21.68 | 3185.50 | 21.53 | 3140.17 | 21.43 |
| Minimum of Months | 426.67 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.40 | 710.67 | 23.41 | 710.67 | 23.41 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 458.17 | 21.10 | 458.17 | 21.10 |
| February | 672.00 | 21.10 | 462.83 | 21.10 | 462.83 | 21.10 |
| March | 744.00 | 21.10 | 444.00 | 21.10 | 444.00 | 21.10 |
| April | 720.00 | 21.30 | 56.67 | 21.28 | 56.67 | 21.27 |
| May | 744.00 | 21.55 | 0.00 | 21.55 | 0.00 | 21.55 |
| June | 649.83 | 22.85 | 9.50 | 22.86 | 0.00 | 22.86 |
| July | 418.67 | 23.34 | 13.17 | 23.36 | 0.00 | 23.36 |
| August | 421.67 | 23.57 | 0.00 | 23.57 | 0.00 | 23.57 |
| September | 692.17 | 23.03 | 0.00 | 23.03 | 0.00 | 23.03 |
| October | 744.00 | 21.34 | 0.00 | 21.34 | 0.00 | 21.34 |
| November | 720.00 | 21.10 | 179.33 | 21.10 | 179.33 | 21.10 |
| December | 744.00 | 21.10 | 570.67 | 21.10 | 570.67 | 21.10 |
| Annual Sum or Average | 8014.33 | 21.74 | 2194.33 | 21.61 | 2171.67 | 21.52 |
| Minimum of Months | 418.67 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.57 | 570.67 | 23.57 | 570.67 | 23.57 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 457.83 | 21.10 | 457.83 | 21.10 |
| February | 672.00 | 21.10 | 462.50 | 21.10 | 462.50 | 21.10 |
| March | 744.00 | 21.10 | 444.17 | 21.10 | 444.17 | 21.10 |
| April | 720.00 | 21.30 | 56.00 | 21.29 | 56.00 | 21.27 |
| May | 744.00 | 21.55 | 0.00 | 21.55 | 0.00 | 21.55 |
| June | 649.67 | 22.84 | 9.50 | 22.85 | 0.00 | 22.85 |
| July | 419.17 | 23.36 | 12.83 | 23.38 | 0.00 | 23.38 |
| August | 412.50 | 23.58 | 0.00 | 23.58 | 0.00 | 23.58 |
| September | 689.33 | 23.05 | 0.00 | 23.05 | 0.00 | 23.05 |
| October | 744.00 | 21.34 | 0.00 | 21.34 | 0.00 | 21.34 |
| November | 720.00 | 21.10 | 179.50 | 21.10 | 179.50 | 21.10 |
| December | 744.00 | 21.10 | 570.00 | 21.10 | 570.00 | 21.10 |
| Annual Sum or Average | 8002.67 | 21.74 | 2192.33 | 21.61 | 2170.00 | 21.52 |
| Minimum of Months | 412.50 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.58 | 570.00 | 23.58 | 570.00 | 23.58 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.12 | 143.83 | 21.11 | 143.83 | 21.11 |
| February | 473.00 | 21.12 | 89.67 | 21.12 | 89.67 | 21.12 |
| March | 506.00 | 21.11 | 151.50 | 21.11 | 151.50 | 21.10 |
| April | 494.00 | 21.83 | 7.67 | 21.82 | 7.67 | 21.81 |
| May | 512.33 | 22.15 | 0.00 | 22.15 | 0.00 | 22.15 |
| June | 347.83 | 23.08 | 16.00 | 23.12 | 0.00 | 23.12 |
| July | 194.83 | 23.39 | 56.33 | 23.53 | 0.00 | 23.53 |
| August | 58.67 | 23.71 | 52.17 | 23.85 | 0.00 | 23.85 |
| September | 174.00 | 23.50 | 40.67 | 23.59 | 0.00 | 23.59 |
| October | 503.33 | 22.12 | 0.00 | 22.12 | 0.00 | 22.12 |
| November | 510.00 | 21.16 | 11.17 | 21.16 | 11.17 | 21.16 |
| December | 533.00 | 21.10 | 218.33 | 21.10 | 218.33 | 21.10 |
| Annual Sum or Average | 4840.00 | 21.76 | 787.33 | 21.75 | 622.17 | 21.68 |
| Minimum of Months | 58.67 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.71 | 218.33 | 23.85 | 218.33 | 23.85 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.11 | 189.50 | 21.11 | 189.50 | 21.11 |
| February | 473.00 | 21.12 | 138.00 | 21.11 | 138.00 | 21.11 |
| March | 506.00 | 21.11 | 209.83 | 21.10 | 209.83 | 21.10 |
| April | 491.67 | 21.84 | 8.17 | 21.83 | 8.17 | 21.82 |
| May | 512.00 | 22.19 | 0.00 | 22.19 | 0.00 | 22.19 |
| June | 337.33 | 23.11 | 16.17 | 23.15 | 0.00 | 23.15 |
| July | 171.67 | 23.41 | 65.17 | 23.57 | 0.00 | 23.57 |
| August | 41.17 | 23.73 | 68.00 | 23.90 | 0.00 | 23.90 |
| September | 162.67 | 23.52 | 46.83 | 23.63 | 0.00 | 23.63 |
| October | 500.50 | 22.13 | 0.00 | 22.13 | 0.00 | 22.13 |
| November | 510.00 | 21.15 | 24.17 | 21.15 | 24.17 | 21.15 |
| December | 533.00 | 21.10 | 315.67 | 21.10 | 315.67 | 21.10 |
| Annual Sum or Average | 4772.00 | 21.74 | 1081.50 | 21.72 | 885.33 | 21.64 |
| Minimum of Months | 41.17 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.73 | 315.67 | 23.90 | 315.67 | 23.90 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.22 | 105.83 | 21.20 | 105.83 | 21.19 |
| February | 473.00 | 21.27 | 28.50 | 21.26 | 28.50 | 21.25 |
| March | 506.00 | 21.23 | 22.67 | 21.22 | 22.67 | 21.22 |
| April | 418.33 | 22.77 | 9.83 | 22.80 | 0.00 | 22.80 |
| May | 391.17 | 22.95 | 11.17 | 22.98 | 0.00 | 22.98 |
| June | 149.33 | 23.48 | 68.67 | 23.65 | 0.00 | 23.65 |
| July | 93.00 | 23.45 | 131.00 | 23.77 | 0.00 | 23.77 |
| August | 37.17 | 23.73 | 132.83 | 23.94 | 0.00 | 23.94 |
| September | 169.83 | 23.43 | 65.00 | 23.59 | 0.00 | 23.59 |
| October | 480.33 | 22.19 | 0.00 | 22.19 | 0.00 | 22.19 |
| November | 510.00 | 21.25 | 17.33 | 21.25 | 17.33 | 21.24 |
| December | 533.00 | 21.11 | 152.83 | 21.11 | 152.83 | 21.10 |
| Annual Sum or Average | 4294.17 | 21.87 | 745.67 | 22.00 | 327.17 | 21.94 |
| Minimum of Months | 37.17 | 21.11 | 0.00 | 21.11 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 23.73 | 152.83 | 23.94 | 152.83 | 23.94 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 277.33 | 21.10 | 277.33 | 21.10 |
| February | 672.00 | 21.10 | 142.00 | 21.10 | 142.00 | 21.10 |
| March | 744.00 | 21.14 | 70.83 | 21.14 | 70.83 | 21.13 |
| April | 682.50 | 22.21 | 0.00 | 22.21 | 0.00 | 22.21 |
| May | 645.83 | 22.72 | 11.50 | 22.74 | 0.00 | 22.74 |
| June | 235.67 | 23.50 | 72.00 | 23.62 | 0.00 | 23.62 |
| July | 138.67 | 23.53 | 155.67 | 23.78 | 0.00 | 23.78 |
| August | 121.67 | 23.67 | 101.50 | 23.82 | 0.00 | 23.82 |
| September | 439.67 | 23.32 | 22.83 | 23.36 | 0.00 | 23.36 |
| October | 744.00 | 21.68 | 0.00 | 21.68 | 0.00 | 21.68 |
| November | 720.00 | 21.11 | 114.17 | 21.11 | 114.17 | 21.11 |
| December | 744.00 | 21.10 | 402.33 | 21.10 | 402.33 | 21.10 |
| Annual Sum or Average | 6632.00 | 21.77 | 1370.17 | 21.79 | 1006.67 | 21.71 |
| Minimum of Months | 121.67 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.67 | 402.33 | 23.82 | 402.33 | 23.82 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.23 | 104.33 | 21.21 | 104.33 | 21.19 |
| February | 473.00 | 21.24 | 31.83 | 21.23 | 31.83 | 21.22 |
| March | 506.00 | 21.23 | 23.00 | 21.22 | 23.00 | 21.22 |
| April | 421.50 | 22.85 | 9.33 | 22.88 | 0.00 | 22.88 |
| May | 387.33 | 22.97 | 3.17 | 22.98 | 0.00 | 22.98 |
| June | 170.50 | 23.47 | 54.33 | 23.60 | 0.00 | 23.60 |
| July | 94.50 | 23.50 | 109.50 | 23.77 | 0.00 | 23.77 |
| August | 36.33 | 23.67 | 125.17 | 23.93 | 0.00 | 23.93 |
| September | 164.00 | 23.46 | 64.50 | 23.61 | 0.00 | 23.61 |
| October | 479.33 | 22.20 | 0.00 | 22.20 | 0.00 | 22.20 |
| November | 510.00 | 21.25 | 17.00 | 21.25 | 17.00 | 21.24 |
| December | 533.00 | 21.11 | 143.33 | 21.11 | 143.33 | 21.11 |
| Annual Sum or Average | 4308.50 | 21.89 | 685.50 | 21.99 | 319.50 | 21.94 |
| Minimum of Months | 36.33 | 21.11 | 0.00 | 21.11 | 0.00 | 21.11 |
| Maximum of Months | 533.00 | 23.67 | 143.33 | 23.93 | 143.33 | 23.93 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 262.83 | 21.10 | 262.83 | 21.10 |
| February | 672.00 | 21.10 | 148.83 | 21.10 | 148.83 | 21.10 |
| March | 744.00 | 21.13 | 63.33 | 21.13 | 63.33 | 21.13 |
| April | 673.00 | 22.35 | 0.00 | 22.35 | 0.00 | 22.35 |
| May | 636.50 | 22.82 | 5.00 | 22.83 | 0.00 | 22.83 |
| June | 224.83 | 23.45 | 68.83 | 23.58 | 0.00 | 23.58 |
| July | 120.00 | 23.49 | 136.67 | 23.76 | 0.00 | 23.76 |
| August | 109.50 | 23.64 | 77.33 | 23.79 | 0.00 | 23.79 |
| September | 366.50 | 23.39 | 14.50 | 23.41 | 0.00 | 23.41 |
| October | 744.00 | 21.71 | 0.00 | 21.71 | 0.00 | 21.71 |
| November | 720.00 | 21.11 | 105.83 | 21.11 | 105.83 | 21.10 |
| December | 744.00 | 21.10 | 371.83 | 21.10 | 371.83 | 21.10 |
| Annual Sum or Average | 6498.33 | 21.77 | 1255.00 | 21.77 | 952.67 | 21.70 |
| Minimum of Months | 109.50 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.64 | 371.83 | 23.79 | 371.83 | 23.79 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.12 | 130.50 | 21.11 | 130.50 | 21.11 |
| February | 672.00 | 21.10 | 18.00 | 21.10 | 18.00 | 21.10 |
| March | 744.00 | 21.20 | 0.00 | 21.20 | 0.00 | 21.20 |
| April | 694.33 | 22.42 | 0.00 | 22.42 | 0.00 | 22.42 |
| May | 647.00 | 23.04 | 0.00 | 23.04 | 0.00 | 23.04 |
| June | 148.50 | 23.65 | 27.83 | 23.71 | 0.00 | 23.71 |
| July | 75.00 | 23.70 | 46.00 | 23.82 | 0.00 | 23.82 |
| August | 50.67 | 23.81 | 35.50 | 23.89 | 0.00 | 23.89 |
| September | 366.67 | 23.60 | 1.83 | 23.60 | 0.00 | 23.60 |
| October | 744.00 | 22.03 | 0.00 | 22.03 | 0.00 | 22.03 |
| November | 720.00 | 21.15 | 19.00 | 21.15 | 19.00 | 21.15 |
| December | 744.00 | 21.10 | 98.50 | 21.10 | 98.50 | 21.10 |
| Annual Sum or Average | 6350.17 | 21.83 | 377.17 | 21.83 | 266.00 | 21.81 |
| Minimum of Months | 50.67 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.81 | 130.50 | 23.89 | 130.50 | 23.89 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.12 | 130.17 | 21.11 | 130.17 | 21.11 |
| February | 672.00 | 21.10 | 18.33 | 21.10 | 18.33 | 21.10 |
| March | 744.00 | 21.20 | 0.00 | 21.20 | 0.00 | 21.20 |
| April | 692.17 | 22.44 | 0.00 | 22.44 | 0.00 | 22.44 |
| May | 646.50 | 23.06 | 0.00 | 23.06 | 0.00 | 23.06 |
| June | 149.00 | 23.65 | 27.67 | 23.70 | 0.00 | 23.70 |
| July | 73.83 | 23.70 | 45.50 | 23.82 | 0.00 | 23.82 |
| August | 50.00 | 23.81 | 35.00 | 23.89 | 0.00 | 23.89 |
| September | 351.17 | 23.60 | 2.17 | 23.60 | 0.00 | 23.60 |
| October | 744.00 | 22.03 | 0.00 | 22.03 | 0.00 | 22.03 |
| November | 720.00 | 21.15 | 18.50 | 21.15 | 18.50 | 21.15 |
| December | 744.00 | 21.10 | 97.83 | 21.10 | 97.83 | 21.10 |
| Annual Sum or Average | 6330.67 | 21.83 | 375.17 | 21.83 | 264.83 | 21.81 |
| Minimum of Months | 50.00 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 23.81 | 130.17 | 23.89 | 130.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.45 | 27.00 | 21.43 | 27.00 | 21.42 |
| February | 473.00 | 21.46 | 0.50 | 21.46 | 0.50 | 21.46 |
| March | 506.00 | 21.38 | 0.00 | 21.38 | 0.00 | 21.38 |
| April | 412.83 | 23.17 | 0.00 | 23.17 | 0.00 | 23.17 |
| May | 362.50 | 23.32 | 0.33 | 23.32 | 0.00 | 23.32 |
| June | 76.67 | 23.62 | 35.33 | 23.74 | 0.00 | 23.74 |
| July | 54.67 | 23.69 | 81.67 | 23.88 | 0.00 | 23.88 |
| August | 8.83 | 23.87 | 101.83 | 23.99 | 0.00 | 23.99 |
| September | 98.17 | 23.69 | 61.33 | 23.81 | 0.00 | 23.81 |
| October | 436.50 | 22.66 | 0.00 | 22.66 | 0.00 | 22.66 |
| November | 510.00 | 21.58 | 0.00 | 21.58 | 0.00 | 21.58 |
| December | 533.00 | 21.14 | 23.00 | 21.14 | 23.00 | 21.14 |
| Annual Sum or Average | 4005.17 | 22.03 | 331.00 | 22.14 | 50.50 | 22.13 |
| Minimum of Months | 8.83 | 21.14 | 0.00 | 21.14 | 0.00 | 21.14 |
| Maximum of Months | 533.00 | 23.87 | 101.83 | 23.99 | 27.00 | 23.99 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.00 | 21.45 | 27.00 | 21.43 | 27.00 | 21.42 |
| February | 473.00 | 21.45 | 0.67 | 21.45 | 0.67 | 21.45 |
| March | 506.00 | 21.38 | 0.00 | 21.38 | 0.00 | 21.38 |
| April | 411.17 | 23.18 | 0.00 | 23.18 | 0.00 | 23.18 |
| May | 362.50 | 23.32 | 0.33 | 23.32 | 0.00 | 23.32 |
| June | 78.50 | 23.62 | 34.83 | 23.74 | 0.00 | 23.74 |
| July | 54.33 | 23.69 | 80.67 | 23.88 | 0.00 | 23.88 |
| August | 9.00 | 23.87 | 101.83 | 23.99 | 0.00 | 23.99 |
| September | 97.83 | 23.69 | 61.83 | 23.81 | 0.00 | 23.81 |
| October | 435.67 | 22.66 | 0.00 | 22.66 | 0.00 | 22.66 |
| November | 510.00 | 21.58 | 0.00 | 21.58 | 0.00 | 21.58 |
| December | 533.00 | 21.14 | 23.00 | 21.14 | 23.00 | 21.14 |
| Annual Sum or Average | 4004.00 | 22.03 | 330.17 | 22.14 | 50.67 | 22.13 |
| Minimum of Months | 9.00 | 21.14 | 0.00 | 21.14 | 0.00 | 21.14 |
| Maximum of Months | 533.00 | 23.87 | 101.83 | 23.99 | 27.00 | 23.99 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 531.67 | 21.17 | 382.83 | 21.14 | 382.83 | 21.13 |
| February | 469.83 | 21.21 | 330.33 | 21.16 | 330.33 | 21.14 |
| March | 506.00 | 21.18 | 324.67 | 21.15 | 324.67 | 21.13 |
| April | 434.67 | 21.82 | 111.00 | 21.80 | 87.33 | 21.70 |
| May | 429.50 | 21.75 | 43.33 | 21.82 | 21.50 | 21.79 |
| June | 324.17 | 22.23 | 86.00 | 22.58 | 2.17 | 22.58 |
| July | 302.67 | 22.48 | 118.83 | 22.91 | 0.00 | 22.91 |
| August | 287.00 | 22.61 | 119.00 | 23.02 | 0.00 | 23.02 |
| September | 360.17 | 22.15 | 65.33 | 22.43 | 0.00 | 22.43 |
| October | 498.83 | 21.43 | 68.17 | 21.40 | 65.50 | 21.37 |
| November | 508.33 | 21.18 | 256.17 | 21.15 | 256.17 | 21.14 |
| December | 533.00 | 21.11 | 497.00 | 21.10 | 497.00 | 21.10 |
| Annual Sum or Average | 5185.83 | 21.59 | 2402.67 | 21.60 | 1967.50 | 21.50 |
| Minimum of Months | 287.00 | 21.11 | 43.33 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 22.61 | 497.00 | 23.02 | 497.00 | 23.02 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 612.33 | 21.10 | 612.33 | 21.10 |
| February | 672.00 | 21.10 | 541.83 | 21.10 | 541.83 | 21.10 |
| March | 744.00 | 21.12 | 481.00 | 21.11 | 481.00 | 21.11 |
| April | 667.17 | 21.71 | 167.17 | 21.62 | 157.50 | 21.54 |
| May | 660.00 | 21.76 | 69.67 | 21.83 | 37.00 | 21.79 |
| June | 456.50 | 22.31 | 115.67 | 22.65 | 1.67 | 22.64 |
| July | 407.33 | 22.58 | 190.67 | 23.03 | 0.00 | 23.03 |
| August | 430.00 | 22.58 | 151.50 | 22.95 | 0.00 | 22.95 |
| September | 600.17 | 22.09 | 40.67 | 22.20 | 2.67 | 22.19 |
| October | 744.00 | 21.29 | 160.33 | 21.26 | 160.33 | 21.23 |
| November | 720.00 | 21.10 | 431.67 | 21.10 | 431.67 | 21.10 |
| December | 744.00 | 21.10 | 726.83 | 21.10 | 726.83 | 21.10 |
| Annual Sum or Average | 7589.17 | 21.55 | 3689.33 | 21.54 | 3152.83 | 21.44 |
| Minimum of Months | 407.33 | 21.10 | 40.67 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 22.58 | 726.83 | 23.03 | 726.83 | 23.03 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 531.67 | 21.18 | 384.83 | 21.14 | 384.83 | 21.13 |
| February | 471.00 | 21.19 | 336.83 | 21.15 | 336.83 | 21.14 |
| March | 506.00 | 21.17 | 329.83 | 21.14 | 329.83 | 21.13 |
| April | 443.33 | 21.88 | 100.83 | 21.85 | 78.67 | 21.76 |
| May | 435.17 | 21.77 | 33.83 | 21.81 | 20.33 | 21.78 |
| June | 330.50 | 22.21 | 69.33 | 22.50 | 2.33 | 22.49 |
| July | 304.17 | 22.51 | 109.83 | 22.90 | 0.00 | 22.90 |
| August | 289.50 | 22.62 | 112.67 | 23.01 | 0.00 | 23.01 |
| September | 358.67 | 22.17 | 60.17 | 22.43 | 0.00 | 22.43 |
| October | 499.33 | 21.44 | 67.00 | 21.41 | 63.83 | 21.38 |
| November | 508.50 | 21.18 | 254.83 | 21.15 | 254.83 | 21.14 |
| December | 533.00 | 21.11 | 495.83 | 21.10 | 495.83 | 21.10 |
| Annual Sum or Average | 5210.83 | 21.60 | 2355.83 | 21.59 | 1967.33 | 21.49 |
| Minimum of Months | 289.50 | 21.11 | 33.83 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 533.00 | 22.62 | 495.83 | 23.01 | 495.83 | 23.01 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 612.00 | 21.10 | 612.00 | 21.10 |
| February | 672.00 | 21.10 | 559.83 | 21.10 | 559.83 | 21.10 |
| March | 744.00 | 21.12 | 474.00 | 21.11 | 474.00 | 21.11 |
| April | 662.83 | 21.85 | 139.33 | 21.72 | 139.33 | 21.63 |
| May | 653.67 | 21.87 | 61.83 | 21.90 | 37.17 | 21.86 |
| June | 425.67 | 22.31 | 113.33 | 22.66 | 2.50 | 22.65 |
| July | 360.17 | 22.58 | 195.33 | 23.08 | 0.00 | 23.08 |
| August | 384.33 | 22.59 | 193.17 | 23.06 | 0.00 | 23.06 |
| September | 572.33 | 22.23 | 38.33 | 22.33 | 1.83 | 22.32 |
| October | 744.00 | 21.30 | 153.67 | 21.26 | 153.67 | 21.24 |
| November | 720.00 | 21.10 | 440.83 | 21.10 | 440.83 | 21.10 |
| December | 744.00 | 21.10 | 724.50 | 21.10 | 724.50 | 21.10 |
| Annual Sum or Average | 7427.00 | 21.56 | 3706.17 | 21.55 | 3145.67 | 21.45 |
| Minimum of Months | 360.17 | 21.10 | 38.33 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 22.59 | 724.50 | 23.08 | 724.50 | 23.08 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 510.67 | 21.10 | 510.67 | 21.10 |
| February | 672.00 | 21.10 | 448.83 | 21.10 | 448.83 | 21.10 |
| March | 744.00 | 21.12 | 396.50 | 21.11 | 396.50 | 21.11 |
| April | 692.67 | 21.80 | 69.33 | 21.73 | 69.33 | 21.68 |
| May | 684.33 | 21.90 | 20.83 | 21.92 | 9.00 | 21.91 |
| June | 446.83 | 22.64 | 69.33 | 22.82 | 0.00 | 22.82 |
| July | 381.67 | 22.89 | 147.67 | 23.20 | 0.00 | 23.20 |
| August | 413.17 | 22.92 | 75.50 | 23.09 | 0.00 | 23.09 |
| September | 634.17 | 22.36 | 12.17 | 22.39 | 0.00 | 22.39 |
| October | 744.00 | 21.28 | 59.67 | 21.27 | 59.67 | 21.25 |
| November | 720.00 | 21.10 | 345.67 | 21.10 | 345.67 | 21.10 |
| December | 744.00 | 21.10 | 674.83 | 21.10 | 674.83 | 21.10 |
| Annual Sum or Average | 7620.83 | 21.64 | 2831.00 | 21.58 | 2514.50 | 21.49 |
| Minimum of Months | 381.67 | 21.10 | 12.17 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 22.92 | 674.83 | 23.20 | 674.83 | 23.20 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 21.10 | 510.33 | 21.10 | 510.33 | 21.10 |
| February | 672.00 | 21.10 | 451.50 | 21.10 | 451.50 | 21.10 |
| March | 744.00 | 21.12 | 396.67 | 21.11 | 396.67 | 21.11 |
| April | 691.83 | 21.81 | 69.17 | 21.75 | 69.17 | 21.69 |
| May | 683.33 | 21.91 | 20.83 | 21.94 | 8.83 | 21.93 |
| June | 444.33 | 22.64 | 68.83 | 22.82 | 0.00 | 22.82 |
| July | 374.83 | 22.89 | 147.50 | 23.20 | 0.00 | 23.20 |
| August | 409.33 | 22.92 | 79.50 | 23.09 | 0.00 | 23.09 |
| September | 631.83 | 22.38 | 12.50 | 22.41 | 0.00 | 22.41 |
| October | 744.00 | 21.28 | 59.50 | 21.27 | 59.50 | 21.26 |
| November | 720.00 | 21.10 | 345.83 | 21.10 | 345.83 | 21.10 |
| December | 744.00 | 21.10 | 674.33 | 21.10 | 674.33 | 21.10 |
| Annual Sum or Average | 7603.50 | 21.64 | 2836.50 | 21.58 | 2516.17 | 21.49 |
| Minimum of Months | 374.83 | 21.10 | 12.50 | 21.10 | 0.00 | 21.10 |
| Maximum of Months | 744.00 | 22.92 | 674.33 | 23.20 | 674.33 | 23.20 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 531.17 | 21.21 | 278.33 | 21.17 | 278.33 | 21.15 |
| February | 470.67 | 21.25 | 204.00 | 21.20 | 204.00 | 21.18 |
| March | 506.00 | 21.21 | 246.00 | 21.17 | 246.00 | 21.15 |
| April | 447.17 | 22.04 | 36.50 | 22.05 | 22.83 | 22.01 |
| May | 440.17 | 21.97 | 12.83 | 21.99 | 6.00 | 21.98 |
| June | 309.17 | 22.56 | 59.83 | 22.80 | 0.00 | 22.80 |
| July | 277.33 | 22.80 | 97.33 | 23.11 | 0.00 | 23.11 |
| August | 264.50 | 22.99 | 106.67 | 23.28 | 0.00 | 23.28 |
| September | 342.00 | 22.50 | 54.00 | 22.71 | 0.00 | 22.71 |
| October | 498.33 | 21.58 | 10.67 | 21.57 | 10.67 | 21.56 |
| November | 507.83 | 21.23 | 156.50 | 21.20 | 156.50 | 21.18 |
| December | 533.00 | 21.12 | 415.33 | 21.11 | 415.33 | 21.11 |
| Annual Sum or Average | 5127.33 | 21.72 | 1678.00 | 21.71 | 1339.67 | 21.61 |
| Minimum of Months | 264.50 | 21.12 | 10.67 | 21.11 | 0.00 | 21.11 |
| Maximum of Months | 533.00 | 22.99 | 415.33 | 23.28 | 415.33 | 23.28 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 531.00 | 21.21 | 277.67 | 21.17 | 277.67 | 21.15 |
| February | 470.67 | 21.24 | 207.00 | 21.20 | 207.00 | 21.18 |
| March | 506.00 | 21.21 | 246.00 | 21.17 | 246.00 | 21.15 |
| April | 446.67 | 22.04 | 36.33 | 22.06 | 22.67 | 22.01 |
| May | 440.17 | 21.97 | 12.67 | 21.99 | 6.00 | 21.97 |
| June | 310.33 | 22.56 | 59.33 | 22.79 | 0.00 | 22.79 |
| July | 278.17 | 22.80 | 97.50 | 23.11 | 0.00 | 23.11 |
| August | 265.00 | 22.99 | 106.83 | 23.28 | 0.00 | 23.28 |
| September | 340.67 | 22.50 | 54.17 | 22.70 | 0.00 | 22.70 |
| October | 498.67 | 21.58 | 10.83 | 21.57 | 10.83 | 21.56 |
| November | 507.67 | 21.23 | 156.50 | 21.20 | 156.50 | 21.18 |
| December | 533.00 | 21.12 | 415.00 | 21.11 | 415.00 | 21.11 |
| Annual Sum or Average | 5128.00 | 21.72 | 1679.83 | 21.71 | 1341.67 | 21.61 |
| Minimum of Months | 265.00 | 21.12 | 10.83 | 21.11 | 0.00 | 21.11 |
| Maximum of Months | 533.00 | 22.99 | 415.00 | 23.28 | 415.00 | 23.28 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 20.68 | 720.33 | 20.69 | 720.33 | 20.69 |
| February | 672.00 | 20.84 | 672.00 | 20.84 | 672.00 | 20.84 |
| March | 744.00 | 21.05 | 744.00 | 21.05 | 744.00 | 21.05 |
| April | 720.00 | 22.91 | 720.00 | 22.91 | 720.00 | 22.91 |
| May | 740.33 | 23.06 | 723.83 | 23.07 | 721.33 | 23.07 |
| June | 720.00 | 24.30 | 718.00 | 24.31 | 718.00 | 24.31 |
| July | 744.00 | 24.74 | 744.00 | 24.74 | 744.00 | 24.74 |
| August | 744.00 | 24.70 | 744.00 | 24.70 | 744.00 | 24.70 |
| September | 720.00 | 23.83 | 720.00 | 23.83 | 720.00 | 23.83 |
| October | 744.00 | 21.79 | 730.50 | 21.79 | 730.50 | 21.79 |
| November | 720.00 | 20.89 | 557.67 | 20.92 | 557.67 | 20.94 |
| December | 744.00 | 20.34 | 561.83 | 20.35 | 561.83 | 20.36 |
| Annual Sum or Average | 8756.33 | 22.43 | 8356.17 | 22.48 | 8353.67 | 22.49 |
| Minimum of Months | 672.00 | 20.34 | 557.67 | 20.35 | 557.67 | 20.36 |
| Maximum of Months | 744.00 | 24.74 | 744.00 | 24.74 | 744.00 | 24.74 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 18.25 | 704.67 | 18.18 | 704.67 | 18.16 |
| February | 672.00 | 18.38 | 660.17 | 18.36 | 660.17 | 18.35 |
| March | 744.00 | 18.70 | 691.50 | 18.63 | 691.50 | 18.60 |
| April | 713.50 | 20.46 | 277.50 | 19.99 | 277.50 | 19.73 |
| May | 739.00 | 21.13 | 129.00 | 20.75 | 129.00 | 20.47 |
| June | 558.67 | 22.43 | 153.50 | 22.81 | 60.33 | 22.85 |
| July | 382.83 | 23.12 | 317.50 | 23.94 | 92.67 | 24.04 |
| August | 240.67 | 23.37 | 361.67 | 24.26 | 97.83 | 24.35 |
| September | 481.33 | 22.70 | 159.33 | 23.06 | 62.33 | 23.08 |
| October | 744.00 | 20.62 | 250.50 | 20.16 | 250.50 | 19.88 |
| November | 720.00 | 19.06 | 558.83 | 18.82 | 558.83 | 18.73 |
| December | 744.00 | 18.14 | 740.33 | 18.14 | 740.33 | 18.14 |
| Annual Sum or Average | 7484.00 | 20.12 | 5004.50 | 19.92 | 4325.67 | 19.64 |
| Minimum of Months | 240.67 | 18.14 | 129.00 | 18.14 | 60.33 | 18.14 |
| Maximum of Months | 744.00 | 23.37 | 740.33 | 24.26 | 740.33 | 24.35 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 22.16 | 744.00 | 22.16 | 744.00 | 22.16 |
| February | 672.00 | 22.26 | 672.00 | 22.26 | 672.00 | 22.26 |
| March | 744.00 | 22.34 | 744.00 | 22.34 | 744.00 | 22.34 |
| April | 720.00 | 24.27 | 720.00 | 24.27 | 720.00 | 24.27 |
| May | 744.00 | 24.74 | 744.00 | 24.74 | 744.00 | 24.74 |
| June | 720.00 | 25.53 | 720.00 | 25.53 | 720.00 | 25.53 |
| July | 744.00 | 25.68 | 744.00 | 25.68 | 744.00 | 25.68 |
| August | 744.00 | 25.70 | 744.00 | 25.70 | 744.00 | 25.70 |
| September | 720.00 | 25.40 | 720.00 | 25.40 | 720.00 | 25.40 |
| October | 744.00 | 23.54 | 744.00 | 23.54 | 744.00 | 23.54 |
| November | 720.00 | 22.30 | 720.00 | 22.30 | 720.00 | 22.30 |
| December | 744.00 | 21.82 | 744.00 | 21.82 | 744.00 | 21.82 |
| Annual Sum or Average | 8760.00 | 23.82 | 8760.00 | 23.82 | 8760.00 | 23.82 |
| Minimum of Months | 672.00 | 21.82 | 672.00 | 21.82 | 672.00 | 21.82 |
| Maximum of Months | 744.00 | 25.70 | 744.00 | 25.70 | 744.00 | 25.70 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 65076793.14 | 16749059.68 | 33.26 | 65076793.14 | 0.00 | 0.00 | 0.30 | 30-APR-16:10 | 0.00 | 01-APR-00:10 | 1475.64 | 30-APR-16:10 | 1475.64 | 30-APR-16:10 | 0.00 | 29-APR-17:13 | 373.98 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 42632282.06 | 10991466.43 | 41.00 | 40783130.77 | 1849151.29 | 0.00 | 0.16 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 | 779.78 | 22-MAY-16:10 | 752.08 | 22-MAY-16:05 | 48.56 | 23-MAY-16:13 | 198.97 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.279356E+09 | 70989580.56 | 172.18 | 0.258187E+09 | 21169365.46 | 0.00 | 0.36 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 1797.71 | 13-JUN-17:00 | 1694.75 | 13-JUN-17:00 | 239.64 | 26-JUN-17:10 | 464.83 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.762467E+09 | 0.193901E+09 | 357.11 | 0.703811E+09 | 58656563.36 | 0.00 | 0.45 | 22-JUL-17:30 | 0.00 | 01-JUL-00:10 | 2226.64 | 22-JUL-17:30 | 2226.64 | 22-JUL-17:30 | 220.64 | 23-JUL-17:50 | 593.99 | 22-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.853427E+09 | 0.216247E+09 | 418.54 | 0.793093E+09 | 60334273.82 | 0.00 | 0.39 | 14-AUG-16:12 | 0.00 | 01-AUG-00:10 | 1959.43 | 14-AUG-16:03 | 1936.74 | 14-AUG-16:14 | 213.22 | 18-AUG-16:03 | 501.83 | 14-AUG-16:12 | 0.00 | 01-AUG-00:10 |
| September | 0.639723E+09 | 0.162411E+09 | 326.97 | 0.605670E+09 | 34053318.32 | 0.00 | 0.37 | 13-SEP-16:05 | 0.00 | 01-SEP-00:10 | 1887.86 | 13-SEP-16:03 | 1786.13 | 13-SEP-16:05 | 190.69 | 12-SEP-14:20 | 464.72 | 13-SEP-16:05 | 0.00 | 01-SEP-00:10 |
| October | 63561559.57 | 16597509.88 | 53.00 | 63561559.57 | -0.0 | 0.00 | 0.16 | 03-OCT-16:04 | 0.00 | 01-OCT-00:10 | 745.46 | 03-OCT-16:04 | 745.46 | 03-OCT-16:04 | 0.00 | 03-OCT-16:05 | 193.07 | 03-OCT-16:04 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.270624E+10 | 0.687887E+09 | 1402.07 | 0.253018E+10 | 0.176063E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.853427E+09 | 0.216247E+09 | 418.54 | 0.793093E+09 | 60334273.82 | 0.00 | 0.45 | 0.00 | 2226.64 | 2226.64 | 239.64 | 593.99 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 7167460.98 | 1871081.14 | 5.17 | 7167460.98 | 0.00 | 0.00 | 0.14 | 30-APR-17:40 | 0.00 | 01-APR-00:10 | 545.14 | 30-APR-17:40 | 545.14 | 30-APR-17:40 | 0.00 | 30-APR-19:10 | 141.88 | 30-APR-17:40 | 0.00 | 01-APR-00:10 |
| May | 1017409.88 | 264371.85 | 4.58 | 964662.95 | 52746.93 | 0.00 | 0.04 | 22-MAY-16:05 | 0.00 | 01-MAY-00:10 | 162.37 | 22-MAY-16:05 | 153.04 | 22-MAY-16:05 | 9.34 | 22-MAY-16:10 | 42.04 | 22-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.123480E+09 | 31338301.52 | 82.13 | 0.111379E+09 | 12100829.67 | 0.00 | 0.33 | 13-JUN-17:10 | 0.00 | 01-JUN-00:10 | 1386.35 | 13-JUN-17:10 | 1272.36 | 13-JUN-17:10 | 197.92 | 26-JUN-17:10 | 357.53 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.383914E+09 | 98072971.27 | 238.10 | 0.351959E+09 | 31955300.05 | 0.00 | 0.45 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 1837.78 | 22-JUL-18:00 | 1837.78 | 22-JUL-18:00 | 187.25 | 23-JUL-18:00 | 494.10 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.221668E+09 | 56597662.25 | 205.44 | 0.202974E+09 | 18693640.89 | 0.00 | 0.31 | 14-AUG-17:05 | 0.00 | 01-AUG-00:10 | 1271.37 | 14-AUG-16:50 | 1265.73 | 14-AUG-17:05 | 153.78 | 18-AUG-16:03 | 332.57 | 14-AUG-17:00 | 0.00 | 01-AUG-00:10 |
| September | 39583713.95 | 10108413.29 | 39.08 | 36101251.62 | 3482462.33 | 0.00 | 0.21 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 | 865.36 | 13-SEP-16:30 | 789.64 | 13-SEP-16:30 | 76.41 | 13-SEP-16:12 | 217.28 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.776830E+09 | 0.198253E+09 | 574.50 | 0.710545E+09 | 66284979.86 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.383914E+09 | 98072971.27 | 238.10 | 0.351959E+09 | 31955300.05 | 0.00 | 0.45 | 0.00 | 1837.78 | 1837.78 | 197.92 | 494.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 93525698.73 | 24306206.48 | 51.83 | 93523944.24 | 1754.49 | 0.00 | 0.27 | 28-APR-14:40 | 0.00 | 01-APR-00:10 | 1409.28 | 28-APR-14:40 | 1409.28 | 28-APR-14:40 | 1.10 | 28-APR-09:10 | 357.53 | 28-APR-14:40 | 0.00 | 01-APR-00:10 |
| May | 0.194061E+09 | 49803757.20 | 83.94 | 0.183995E+09 | 10066075.97 | 0.00 | 0.57 | 23-MAY-08:63 | 0.00 | 01-MAY-00:10 | 3239.87 | 23-MAY-08:63 | 3023.00 | 23-MAY-08:63 | 216.86 | 23-MAY-08:63 | 771.40 | 23-MAY-08:63 | 0.00 | 01-MAY-00:10 |
| June | 0.585531E+09 | 0.147321E+09 | 162.39 | 0.534927E+09 | 50604458.59 | 0.00 | 1.00 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 | 6403.33 | 27-JUN-08:62 | 5935.32 | 21-JUN-08:62 | 1452.83 | 27-JUN-08:62 | 1372.21 | 27-JUN-08:62 | 0.00 | 01-JUN-00:10 |
| July | 0.938942E+09 | 0.232812E+09 | 166.45 | 0.853706E+09 | 85236567.34 | 0.00 | 1.00 | 10-JUL-08:62 | 0.00 | 01-JUL-00:10 | 6335.04 | 18-JUL-08:62 | 5998.97 | 21-JUL-08:62 | 1022.37 | 18-JUL-08:62 | 1369.47 | 18-JUL-08:62 | 0.00 | 01-JUL-00:10 |
| August | 0.123940E+10 | 0.305907E+09 | 194.01 | 0.114208E+10 | 97322059.50 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 6348.46 | 17-AUG-08:62 | 6097.82 | 15-AUG-08:62 | 1133.24 | 17-AUG-08:62 | 1370.07 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
| September | 0.934986E+09 | 0.232670E+09 | 163.68 | 0.886049E+09 | 48936903.83 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:10 | 6283.38 | 01-SEP-08:62 | 6066.85 | 25-SEP-08:62 | 884.48 | 01-SEP-08:62 | 1366.85 | 01-SEP-08:62 | 0.00 | 01-SEP-00:10 |
| October | 0.156332E+09 | 40400681.58 | 53.08 | 0.155373E+09 | 959087.88 | 0.00 | 0.24 | 03-OCT-14:30 | 0.00 | 01-OCT-00:10 | 1258.50 | 03-OCT-14:30 | 1258.50 | 03-OCT-14:30 | 63.24 | 10-OCT-14:40 | 322.62 | 03-OCT-14:30 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.414278E+10 | 0.103322E+10 | 875.39 | 0.384965E+10 | 0.293127E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.123940E+10 | 0.305907E+09 | 194.01 | 0.114208E+10 | 97322059.50 | 0.00 | 1.00 | 0.00 | 6403.33 | 6097.82 | 1452.83 | 1372.21 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 4554829.57 | 1195380.12 | 5.67 | 4554829.57 | -0.0 | 0.00 | 0.10 | 30-APR-18:00 | 0.00 | 01-APR-00:10 | 325.35 | 30-APR-18:00 | 325.35 | 30-APR-18:00 | 0.00 | 30-APR-14:30 | 85.21 | 30-APR-18:00 | 0.00 | 01-APR-00:10 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 |
| June | 0.105752E+09 | 26871940.24 | 73.78 | 95537461.98 | 10214869.00 | 0.00 | 0.28 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 983.42 | 13-JUN-17:00 | 893.42 | 13-JUN-17:00 | 142.12 | 26-JUN-16:20 | 256.30 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.315189E+09 | 80392305.37 | 223.46 | 0.289004E+09 | 26184868.93 | 0.00 | 0.42 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 1465.57 | 22-JUL-18:00 | 1465.57 | 22-JUL-18:00 | 153.69 | 23-JUL-18:00 | 396.01 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.228362E+09 | 58275685.57 | 237.62 | 0.208897E+09 | 19465554.93 | 0.00 | 0.28 | 14-AUG-17:40 | 0.00 | 01-AUG-00:10 | 977.75 | 14-AUG-16:50 | 977.48 | 14-AUG-17:30 | 117.16 | 17-AUG-10:00 | 257.90 | 14-AUG-17:40 | 0.00 | 01-AUG-00:10 |
| September | 38744785.36 | 9898186.83 | 49.17 | 35020047.12 | 3724738.24 | 0.00 | 0.19 | 13-SEP-16:20 | 0.00 | 01-SEP-00:10 | 662.00 | 13-SEP-16:20 | 602.25 | 13-SEP-16:20 | 60.17 | 13-SEP-16:12 | 166.73 | 13-SEP-16:20 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.692603E+09 | 0.176633E+09 | 589.70 | 0.633013E+09 | 59590031.10 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.315189E+09 | 80392305.37 | 237.62 | 0.289004E+09 | 26184868.93 | 0.00 | 0.42 | 0.00 | 1465.57 | 1465.57 | 153.69 | 396.01 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 757326.33 | 200335.17 | 2.83 | 757326.33 | -0.0 | 0.00 | 0.04 | 30-APR-19:00 | 0.00 | 01-APR-00:10 | 124.19 | 30-APR-19:00 | 124.19 | 30-APR-19:00 | 0.00 | 30-APR-17:00 | 32.79 | 30-APR-19:00 | 0.00 | 01-APR-00:10 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 |
| June | 70535328.64 | 18000376.54 | 80.24 | 62902724.79 | 7632603.85 | 0.00 | 0.24 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 793.01 | 13-JUN-17:00 | 712.51 | 13-JUN-17:00 | 115.16 | 26-JUN-16:20 | 207.64 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.252420E+09 | 64726756.92 | 242.28 | 0.229554E+09 | 22865925.18 | 0.00 | 0.38 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 1250.02 | 22-JUL-18:00 | 1250.02 | 22-JUL-18:00 | 133.90 | 23-JUL-18:00 | 339.76 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.159482E+09 | 40784733.36 | 215.33 | 0.144682E+09 | 14799825.56 | 0.00 | 0.26 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 | 855.20 | 14-AUG-18:00 | 855.20 | 14-AUG-18:00 | 100.01 | 18-AUG-16:03 | 226.47 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 |
| September | 20053896.35 | 5134271.92 | 31.96 | 18155806.99 | 1898089.36 | 0.00 | 0.16 | 13-SEP-16:40 | 0.00 | 01-SEP-00:10 | 529.71 | 13-SEP-16:40 | 479.32 | 13-SEP-16:50 | 51.22 | 13-SEP-16:12 | 133.87 | 13-SEP-16:40 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.503248E+09 | 0.128846E+09 | 572.64 | 0.456052E+09 | 47196443.95 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.252420E+09 | 64726756.92 | 242.28 | 0.229554E+09 | 22865925.18 | 0.00 | 0.38 | 0.00 | 1250.02 | 1250.02 | 133.90 | 339.76 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 841369.19 | 222512.04 | 2.83 | 841369.19 | -0.0 | 0.00 | 0.04 | 30-APR-19:00 | 0.00 | 01-APR-00:10 | 129.84 | 30-APR-19:00 | 129.84 | 30-APR-19:00 | 0.00 | 30-APR-18:50 | 34.27 | 30-APR-19:00 | 0.00 | 01-APR-00:10 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 |
| June | 70394015.40 | 17962504.71 | 78.90 | 62782898.12 | 7611117.28 | 0.00 | 0.24 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 783.73 | 13-JUN-17:00 | 704.01 | 13-JUN-17:00 | 115.32 | 26-JUN-16:20 | 205.27 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.250522E+09 | 64239375.61 | 239.58 | 0.227922E+09 | 22599482.51 | 0.00 | 0.38 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 1242.59 | 22-JUL-18:00 | 1242.59 | 22-JUL-18:00 | 133.14 | 23-JUL-18:00 | 337.78 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.163021E+09 | 41687515.68 | 219.64 | 0.147962E+09 | 15059200.36 | 0.00 | 0.26 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 | 851.82 | 14-AUG-18:00 | 851.82 | 14-AUG-18:00 | 99.75 | 18-AUG-16:03 | 225.57 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 |
| September | 22069411.84 | 5648468.96 | 36.42 | 19949586.38 | 2119825.47 | 0.00 | 0.16 | 13-SEP-16:40 | 0.00 | 01-SEP-00:10 | 537.25 | 13-SEP-16:40 | 487.15 | 13-SEP-16:50 | 51.83 | 13-SEP-16:12 | 135.73 | 13-SEP-16:40 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.506848E+09 | 0.129760E+09 | 577.37 | 0.459458E+09 | 47389625.61 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.250522E+09 | 64239375.61 | 239.58 | 0.227922E+09 | 22599482.51 | 0.00 | 0.38 | 0.00 | 1242.59 | 1242.59 | 133.14 | 337.78 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 50811677.74 | 13093275.94 | 31.58 | 50811677.74 | -0.0 | 0.00 | 0.27 | 30-APR-16:10 | 0.00 | 01-APR-00:10 | 1114.89 | 30-APR-16:10 | 1114.89 | 30-APR-16:10 | 0.00 | 30-APR-15:50 | 283.92 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 18007421.32 | 4668100.10 | 33.83 | 17289113.98 | 718307.34 | 0.00 | 0.11 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 | 449.05 | 22-MAY-15:10 | 430.26 | 22-MAY-15:10 | 24.44 | 23-MAY-14:00 | 115.36 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.230259E+09 | 58675234.07 | 205.30 | 0.211328E+09 | 18931869.44 | 0.00 | 0.29 | 13-JUN-16:05 | 0.00 | 01-JUN-00:10 | 1222.81 | 13-JUN-16:05 | 1133.22 | 13-JUN-16:05 | 164.35 | 26-JUN-16:20 | 316.91 | 13-JUN-16:05 | 0.00 | 01-JUN-00:10 |
| July | 0.663741E+09 | 0.169078E+09 | 415.72 | 0.608334E+09 | 55407454.72 | 0.00 | 0.40 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 | 1693.57 | 22-JUL-16:10 | 1693.57 | 22-JUL-16:10 | 179.74 | 23-JUL-16:10 | 451.37 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.890919E+09 | 0.225814E+09 | 553.59 | 0.823871E+09 | 67047983.22 | 0.00 | 0.36 | 14-AUG-16:03 | 0.00 | 01-AUG-00:10 | 1529.59 | 14-AUG-15:10 | 1489.14 | 14-AUG-16:05 | 175.09 | 17-AUG-13:00 | 388.98 | 14-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.765358E+09 | 0.194378E+09 | 461.95 | 0.724121E+09 | 41237537.49 | 0.00 | 0.35 | 13-SEP-15:10 | 0.00 | 01-SEP-01:30 | 1533.34 | 13-SEP-15:10 | 1435.66 | 13-SEP-15:10 | 171.26 | 12-SEP-14:20 | 378.11 | 13-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 98864379.80 | 25717822.16 | 79.90 | 98787133.35 | 77246.46 | 0.00 | 0.17 | 03-OCT-15:10 | 0.00 | 01-OCT-00:10 | 709.43 | 03-OCT-15:10 | 709.43 | 03-OCT-15:10 | 7.84 | 08-OCT-16:10 | 183.02 | 03-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.271796E+10 | 0.691424E+09 | 1781.88 | 0.253454E+10 | 0.183420E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.890919E+09 | 0.225814E+09 | 553.59 | 0.823871E+09 | 67047983.22 | 0.00 | 0.40 | 0.00 | 1693.57 | 1693.57 | 179.74 | 451.37 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 58207816.13 | 14985394.76 | 36.50 | 58207816.13 | 0.00 | 0.00 | 0.28 | 30-APR-16:10 | 0.00 | 01-APR-00:10 | 1183.00 | 30-APR-16:10 | 1183.00 | 30-APR-16:10 | 0.00 | 30-APR-12:30 | 300.58 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 21589932.33 | 5597536.84 | 36.17 | 20765496.82 | 824435.51 | 0.00 | 0.11 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 | 463.88 | 22-MAY-15:10 | 444.57 | 22-MAY-15:10 | 26.86 | 23-MAY-14:00 | 119.12 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.259726E+09 | 66165889.48 | 224.75 | 0.238573E+09 | 21153249.10 | 0.00 | 0.29 | 13-JUN-16:05 | 0.00 | 01-JUN-00:10 | 1259.21 | 13-JUN-16:05 | 1168.66 | 13-JUN-16:05 | 171.31 | 26-JUN-17:10 | 326.04 | 13-JUN-16:05 | 0.00 | 01-JUN-00:10 |
| July | 0.740773E+09 | 0.188428E+09 | 442.43 | 0.679295E+09 | 61478501.15 | 0.00 | 0.42 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 | 1784.06 | 22-JUL-16:10 | 1784.06 | 22-JUL-16:10 | 188.49 | 23-JUL-16:10 | 474.10 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.993323E+09 | 0.251584E+09 | 588.96 | 0.919272E+09 | 74051572.52 | 0.00 | 0.36 | 14-AUG-15:10 | 0.00 | 01-AUG-00:10 | 1577.62 | 14-AUG-15:10 | 1533.11 | 14-AUG-16:08 | 179.47 | 17-AUG-13:00 | 399.63 | 14-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.839108E+09 | 0.212965E+09 | 493.08 | 0.794252E+09 | 44856137.98 | 0.00 | 0.36 | 13-SEP-15:10 | 0.00 | 01-SEP-03:00 | 1579.28 | 13-SEP-15:10 | 1480.25 | 13-SEP-15:10 | 174.67 | 12-SEP-14:20 | 388.97 | 13-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.107889E+09 | 28045176.32 | 83.50 | 0.107784E+09 | 104248.90 | 0.00 | 0.18 | 03-OCT-15:10 | 0.00 | 01-OCT-00:10 | 741.57 | 03-OCT-15:10 | 741.57 | 03-OCT-15:10 | 9.00 | 08-OCT-16:10 | 191.11 | 03-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.302062E+10 | 0.767770E+09 | 1905.39 | 0.281815E+10 | 0.202468E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.993323E+09 | 0.251584E+09 | 588.96 | 0.919272E+09 | 74051572.52 | 0.00 | 0.42 | 0.00 | 1784.06 | 1784.06 | 188.49 | 474.10 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.108184E+10 | 0.277976E+09 | 206.67 | 0.108183E+10 | 9669.79 | 0.00 | 0.44 | 30-APR-16:10 | 0.00 | 01-APR-00:10 | 5584.73 | 30-APR-16:10 | 5584.73 | 30-APR-16:10 | 4.43 | 30-APR-08:20 | 1383.78 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.103663E+10 | 0.266074E+09 | 233.31 | 0.101960E+10 | 17028189.34 | 0.00 | 0.35 | 22-MAY-15:30 | 0.00 | 01-MAY-01:30 | 4466.94 | 22-MAY-15:20 | 4342.31 | 22-MAY-16:10 | 247.05 | 23-MAY-16:13 | 1107.34 | 22-MAY-15:30 | 0.00 | 01-MAY-00:10 |
| June | 0.235628E+10 | 0.597822E+09 | 470.13 | 0.223158E+10 | 0.124700E+09 | 0.00 | 0.45 | 13-JUN-17:10 | 0.00 | 01-JUN-00:10 | 5707.89 | 13-JUN-17:10 | 5469.00 | 13-JUN-17:10 | 768.38 | 26-JUN-17:10 | 1454.56 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.334805E+10 | 0.848460E+09 | 587.23 | 0.312939E+10 | 0.218664E+09 | 0.00 | 0.47 | 22-JUL-16:20 | 0.00 | 01-JUL-00:10 | 5922.37 | 22-JUL-16:20 | 5922.37 | 22-JUL-16:20 | 549.87 | 23-JUL-16:10 | 1568.25 | 22-JUL-17:30 | 0.00 | 01-JUL-00:10 |
| August | 0.353667E+10 | 0.892665E+09 | 631.91 | 0.330633E+10 | 0.230335E+09 | 0.00 | 0.44 | 14-AUG-16:03 | 0.00 | 01-AUG-01:50 | 5565.45 | 14-AUG-16:03 | 5524.87 | 14-AUG-16:14 | 552.54 | 18-AUG-16:03 | 1411.90 | 14-AUG-16:12 | 0.00 | 01-AUG-00:10 |
| September | 0.277006E+10 | 0.700800E+09 | 480.08 | 0.264315E+10 | 0.126910E+09 | 0.00 | 0.41 | 12-SEP-15:10 | 0.00 | 01-SEP-02:00 | 5287.44 | 12-SEP-15:10 | 4974.17 | 13-SEP-16:10 | 511.90 | 12-SEP-14:20 | 1290.85 | 12-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.473380E+09 | 0.122498E+09 | 107.56 | 0.472021E+09 | 1358639.37 | 0.00 | 0.26 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 3126.19 | 07-OCT-15:10 | 3126.19 | 07-OCT-15:10 | 76.57 | 10-OCT-14:30 | 800.06 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.146029E+11 | 0.370630E+10 | 2716.87 | 0.138839E+11 | 0.719006E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.353667E+10 | 0.892665E+09 | 631.91 | 0.330633E+10 | 0.230335E+09 | 0.00 | 0.47 | 0.00 | 5922.37 | 5922.37 | 768.38 | 1568.25 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.245342E+09 | 63219939.69 | 60.67 | 0.245342E+09 | -0.0 | 0.00 | 0.35 | 30-APR-17:30 | 0.00 | 01-APR-00:10 | 3769.36 | 30-APR-17:30 | 3769.36 | 30-APR-17:30 | 0.00 | 28-APR-17:30 | 949.42 | 30-APR-17:30 | 0.00 | 01-APR-00:10 |
| May | 0.391129E+09 | 0.100109E+09 | 112.89 | 0.377618E+09 | 13511383.00 | 0.00 | 0.29 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 | 3161.21 | 22-MAY-16:10 | 3044.51 | 22-MAY-16:10 | 230.24 | 23-MAY-16:40 | 790.55 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.163323E+10 | 0.414419E+09 | 415.02 | 0.152967E+10 | 0.103558E+09 | 0.00 | 0.46 | 13-JUN-17:10 | 0.00 | 01-JUN-00:10 | 5126.08 | 13-JUN-17:10 | 4838.61 | 13-JUN-17:10 | 725.41 | 26-JUN-17:30 | 1298.11 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.228995E+10 | 0.581986E+09 | 540.96 | 0.212161E+10 | 0.168341E+09 | 0.00 | 0.47 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 5084.64 | 22-JUL-18:00 | 5084.64 | 22-JUL-18:00 | 487.49 | 23-JUL-18:00 | 1363.53 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.181715E+10 | 0.461977E+09 | 504.49 | 0.167696E+10 | 0.140193E+09 | 0.00 | 0.38 | 14-AUG-17:05 | 0.00 | 01-AUG-00:10 | 4133.94 | 14-AUG-16:23 | 4129.06 | 14-AUG-17:05 | 470.55 | 18-AUG-16:03 | 1072.49 | 14-AUG-17:05 | 0.00 | 01-AUG-00:10 |
| September | 0.678816E+09 | 0.173224E+09 | 239.70 | 0.630793E+09 | 48023341.26 | 0.00 | 0.31 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 | 3397.68 | 13-SEP-16:30 | 3162.71 | 13-SEP-16:30 | 317.34 | 12-SEP-14:40 | 842.79 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 |
| October | 326087.69 | 86108.51 | 1.40 | 326087.69 | 0.00 | 0.00 | 0.01 | 02-OCT-16:02 | 0.00 | 01-OCT-00:10 | 130.45 | 02-OCT-16:02 | 130.45 | 02-OCT-16:02 | 0.00 | 02-OCT-16:08 | 34.31 | 02-OCT-16:02 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.705595E+10 | 0.179502E+10 | 1875.12 | 0.658232E+10 | 0.473626E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.228995E+10 | 0.581986E+09 | 540.96 | 0.212161E+10 | 0.168341E+09 | 0.00 | 0.47 | 0.00 | 5126.08 | 5084.64 | 725.41 | 1363.53 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.117011E+10 | 0.300227E+09 | 237.72 | 0.117008E+10 | 30910.34 | 0.00 | 0.44 | 30-APR-14:10 | 0.00 | 01-APR-00:10 | 4768.97 | 30-APR-14:10 | 4768.97 | 30-APR-14:10 | 11.87 | 30-APR-08:20 | 1178.31 | 30-APR-14:10 | 0.00 | 01-APR-00:10 |
| May | 0.102854E+10 | 0.264056E+09 | 263.48 | 0.101277E+10 | 15770573.57 | 0.00 | 0.35 | 22-MAY-14:40 | 0.00 | 01-MAY-01:10 | 3791.13 | 22-MAY-14:40 | 3688.63 | 22-MAY-14:20 | 216.01 | 23-MAY-14:00 | 940.48 | 22-MAY-14:40 | 0.00 | 01-MAY-00:10 |
| June | 0.230177E+10 | 0.583219E+09 | 469.67 | 0.217918E+10 | 0.122593E+09 | 0.00 | 0.42 | 13-JUN-14:10 | 0.00 | 01-JUN-00:10 | 4637.25 | 13-JUN-14:10 | 4355.59 | 13-JUN-14:10 | 599.34 | 26-JUN-17:10 | 1165.01 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.327787E+10 | 0.829122E+09 | 594.27 | 0.306744E+10 | 0.210423E+09 | 0.00 | 0.49 | 22-JUL-13:00 | 0.00 | 01-JUL-00:10 | 5323.38 | 22-JUL-12:40 | 5256.64 | 22-JUL-13:30 | 489.07 | 23-JUL-16:10 | 1375.51 | 22-JUL-13:00 | 0.00 | 01-JUL-00:10 |
| August | 0.369419E+10 | 0.928643E+09 | 631.68 | 0.345422E+10 | 0.239967E+09 | 0.00 | 0.44 | 14-AUG-13:00 | 0.00 | 01-AUG-00:40 | 4943.47 | 14-AUG-13:00 | 4611.92 | 14-AUG-15:10 | 502.03 | 17-AUG-09:30 | 1201.47 | 14-AUG-13:00 | 0.00 | 01-AUG-00:10 |
| September | 0.297248E+10 | 0.749750E+09 | 500.18 | 0.284004E+10 | 0.132443E+09 | 0.00 | 0.43 | 12-SEP-14:20 | 0.00 | 01-SEP-01:00 | 4780.70 | 12-SEP-14:20 | 4399.55 | 13-SEP-14:10 | 474.70 | 12-SEP-14:20 | 1159.23 | 12-SEP-14:20 | 0.00 | 01-SEP-00:10 |
| October | 0.500890E+09 | 0.129356E+09 | 117.17 | 0.499559E+09 | 1330509.55 | 0.00 | 0.25 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 2612.04 | 07-OCT-15:10 | 2612.04 | 07-OCT-15:10 | 61.70 | 10-OCT-14:10 | 669.18 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.149458E+11 | 0.378437E+10 | 2814.17 | 0.142233E+11 | 0.722558E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.369419E+10 | 0.928643E+09 | 631.68 | 0.345422E+10 | 0.239967E+09 | 0.00 | 0.49 | 0.00 | 5323.38 | 5256.64 | 599.34 | 1375.51 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.261735E+09 | 67660308.27 | 90.75 | 0.261731E+09 | 3974.32 | 0.00 | 0.29 | 30-APR-17:20 | 0.00 | 01-APR-00:10 | 2631.32 | 30-APR-17:20 | 2631.32 | 30-APR-17:20 | 2.62 | 28-APR-09:00 | 668.75 | 30-APR-17:20 | 0.00 | 01-APR-00:10 |
| May | 0.342366E+09 | 87757959.59 | 118.79 | 0.330418E+09 | 11947797.77 | 0.00 | 0.26 | 23-MAY-10:00 | 0.00 | 01-MAY-00:10 | 2391.09 | 23-MAY-10:00 | 2220.25 | 23-MAY-10:10 | 183.60 | 23-MAY-09:40 | 597.54 | 23-MAY-10:00 | 0.00 | 01-MAY-00:10 |
| June | 0.157816E+10 | 0.400517E+09 | 438.63 | 0.147691E+10 | 0.101247E+09 | 0.00 | 0.40 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 3730.74 | 13-JUN-17:00 | 3488.53 | 13-JUN-17:00 | 532.87 | 26-JUN-17:10 | 957.28 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.221706E+10 | 0.563436E+09 | 559.05 | 0.205893E+10 | 0.158125E+09 | 0.00 | 0.43 | 22-JUL-18:30 | 0.00 | 01-JUL-00:10 | 3926.49 | 22-JUL-18:30 | 3926.49 | 22-JUL-18:30 | 400.17 | 23-JUL-18:00 | 1054.92 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.196806E+10 | 0.499741E+09 | 532.38 | 0.181553E+10 | 0.152537E+09 | 0.00 | 0.34 | 14-AUG-17:30 | 0.00 | 01-AUG-00:10 | 3082.19 | 14-AUG-17:30 | 3082.19 | 14-AUG-17:30 | 420.57 | 17-AUG-09:10 | 806.27 | 14-AUG-17:30 | 0.00 | 01-AUG-00:10 |
| September | 0.772777E+09 | 0.197576E+09 | 318.04 | 0.719057E+09 | 53719291.33 | 0.00 | 0.26 | 13-SEP-16:20 | 0.00 | 01-SEP-00:10 | 2437.54 | 13-SEP-16:12 | 2252.66 | 13-SEP-16:20 | 267.14 | 12-SEP-14:20 | 608.12 | 13-SEP-16:12 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.714015E+10 | 0.181669E+10 | 2057.64 | 0.666257E+10 | 0.477579E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.221706E+10 | 0.563436E+09 | 559.05 | 0.205893E+10 | 0.158125E+09 | 0.00 | 0.43 | 0.00 | 3926.49 | 3926.49 | 532.87 | 1054.92 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.125407E+09 | 32492211.94 | 54.47 | 0.125407E+09 | -0.0 | 0.00 | 0.27 | 30-APR-18:50 | 0.00 | 01-APR-00:10 | 2181.78 | 30-APR-18:50 | 2181.78 | 30-APR-18:50 | 0.00 | 30-APR-17:20 | 556.62 | 30-APR-18:50 | 0.00 | 01-APR-00:10 |
| May | 0.207709E+09 | 53534802.46 | 111.11 | 0.199606E+09 | 8102493.08 | 0.00 | 0.18 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 | 1534.96 | 22-MAY-16:10 | 1465.74 | 22-MAY-16:10 | 110.92 | 23-MAY-16:40 | 389.64 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.127353E+10 | 0.324601E+09 | 498.14 | 0.118045E+10 | 93078946.43 | 0.00 | 0.35 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 3008.74 | 13-JUN-17:10 | 2792.32 | 13-JUN-17:10 | 428.46 | 26-JUN-17:10 | 775.87 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.173753E+10 | 0.443553E+09 | 608.30 | 0.159702E+10 | 0.140505E+09 | 0.00 | 0.39 | 22-JUL-18:30 | 0.00 | 01-JUL-00:10 | 3242.95 | 22-JUL-18:30 | 3242.95 | 22-JUL-18:30 | 344.02 | 23-JUL-18:00 | 873.65 | 22-JUL-18:30 | 0.00 | 01-JUL-00:10 |
| August | 0.147373E+10 | 0.375881E+09 | 613.14 | 0.134675E+10 | 0.126986E+09 | 0.00 | 0.31 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 | 2555.43 | 14-AUG-18:00 | 2555.43 | 14-AUG-18:00 | 295.55 | 18-AUG-16:03 | 672.29 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 |
| September | 0.578965E+09 | 0.148222E+09 | 327.71 | 0.532692E+09 | 46273374.21 | 0.00 | 0.24 | 13-SEP-16:50 | 0.00 | 01-SEP-00:10 | 2030.77 | 13-SEP-16:40 | 1873.18 | 13-SEP-17:00 | 205.20 | 12-SEP-14:30 | 508.29 | 13-SEP-16:50 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.539687E+10 | 0.137828E+10 | 2212.86 | 0.498193E+10 | 0.414946E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.173753E+10 | 0.443553E+09 | 613.14 | 0.159702E+10 | 0.140505E+09 | 0.00 | 0.39 | 0.00 | 3242.95 | 3242.95 | 428.46 | 873.65 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.131444E+09 | 34063554.55 | 59.39 | 0.131444E+09 | -0.0 | 0.00 | 0.27 | 30-APR-18:50 | 0.00 | 01-APR-00:10 | 2172.47 | 30-APR-18:50 | 2172.47 | 30-APR-18:50 | 0.00 | 28-APR-15:40 | 554.26 | 30-APR-18:50 | 0.00 | 01-APR-00:10 |
| May | 0.208893E+09 | 53840507.46 | 111.38 | 0.200766E+09 | 8127403.07 | 0.00 | 0.18 | 22-MAY-16:05 | 0.00 | 01-MAY-00:10 | 1538.23 | 22-MAY-16:05 | 1469.72 | 22-MAY-16:05 | 109.83 | 23-MAY-16:40 | 390.44 | 22-MAY-16:05 | 0.00 | 01-MAY-00:10 |
| June | 0.127162E+10 | 0.324115E+09 | 499.60 | 0.117877E+10 | 92853718.33 | 0.00 | 0.35 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 2989.42 | 13-JUN-17:10 | 2774.20 | 13-JUN-17:10 | 425.59 | 26-JUN-17:10 | 771.41 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.173706E+10 | 0.443460E+09 | 608.57 | 0.159725E+10 | 0.139811E+09 | 0.00 | 0.39 | 22-JUL-18:30 | 0.00 | 01-JUL-00:10 | 3224.08 | 22-JUL-18:30 | 3224.08 | 22-JUL-18:30 | 342.27 | 23-JUL-18:00 | 868.69 | 22-JUL-18:30 | 0.00 | 01-JUL-00:10 |
| August | 0.148120E+10 | 0.377761E+09 | 613.65 | 0.135375E+10 | 0.127449E+09 | 0.00 | 0.31 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 | 2540.10 | 14-AUG-17:50 | 2540.10 | 14-AUG-17:50 | 294.25 | 18-AUG-16:03 | 668.23 | 14-AUG-18:00 | 0.00 | 01-AUG-00:10 |
| September | 0.596065E+09 | 0.152610E+09 | 332.55 | 0.548868E+09 | 47196956.89 | 0.00 | 0.24 | 13-SEP-16:40 | 0.00 | 01-SEP-00:10 | 2022.06 | 13-SEP-16:40 | 1862.83 | 13-SEP-16:50 | 206.61 | 12-SEP-14:30 | 506.06 | 13-SEP-16:40 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.542628E+10 | 0.138585E+10 | 2225.13 | 0.501085E+10 | 0.415438E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.173706E+10 | 0.443460E+09 | 613.65 | 0.159725E+10 | 0.139811E+09 | 0.00 | 0.39 | 0.00 | 3224.08 | 3224.08 | 425.59 | 868.69 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.100721E+10 | 0.259635E+09 | 266.31 | 0.100719E+10 | 15471.63 | 0.00 | 0.40 | 30-APR-15:10 | 0.00 | 01-APR-00:10 | 4110.00 | 30-APR-15:10 | 4110.00 | 30-APR-15:10 | 5.74 | 30-APR-08:20 | 1024.78 | 30-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.889398E+09 | 0.229392E+09 | 292.64 | 0.875789E+09 | 13609068.28 | 0.00 | 0.31 | 22-MAY-15:10 | 0.00 | 01-MAY-02:00 | 3144.53 | 22-MAY-15:10 | 3045.28 | 22-MAY-15:10 | 185.83 | 23-MAY-14:00 | 784.83 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.202338E+10 | 0.515240E+09 | 557.28 | 0.190497E+10 | 0.118413E+09 | 0.00 | 0.36 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 | 3766.62 | 13-JUN-15:10 | 3539.93 | 13-JUN-15:10 | 501.55 | 26-JUN-17:10 | 958.86 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.282453E+10 | 0.717909E+09 | 655.34 | 0.262478E+10 | 0.199753E+09 | 0.00 | 0.42 | 22-JUL-15:10 | 0.00 | 01-JUL-00:10 | 4286.35 | 22-JUL-13:30 | 4265.99 | 22-JUL-15:10 | 429.96 | 23-JUL-16:10 | 1134.40 | 22-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.326058E+10 | 0.823972E+09 | 711.20 | 0.303334E+10 | 0.227234E+09 | 0.00 | 0.39 | 14-AUG-14:30 | 0.00 | 01-AUG-07:00 | 4123.59 | 14-AUG-14:20 | 3939.45 | 14-AUG-15:10 | 437.66 | 17-AUG-13:00 | 1024.24 | 14-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.286997E+10 | 0.726234E+09 | 586.14 | 0.273588E+10 | 0.134086E+09 | 0.00 | 0.40 | 12-SEP-14:30 | 0.00 | 01-SEP-07:50 | 4198.47 | 12-SEP-14:30 | 4011.64 | 27-SEP-13:50 | 433.70 | 12-SEP-14:20 | 1022.55 | 12-SEP-14:30 | 0.00 | 01-SEP-00:10 |
| October | 0.603827E+09 | 0.155678E+09 | 144.63 | 0.601001E+09 | 2826044.67 | 0.00 | 0.27 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 2675.06 | 03-OCT-14:10 | 2675.06 | 03-OCT-14:10 | 80.63 | 10-OCT-13:00 | 679.56 | 03-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.134789E+11 | 0.342806E+10 | 3213.53 | 0.127830E+11 | 0.695936E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.326058E+10 | 0.823972E+09 | 711.20 | 0.303334E+10 | 0.227234E+09 | 0.00 | 0.42 | 0.00 | 4286.35 | 4265.99 | 501.55 | 1134.40 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.102388E+10 | 0.263932E+09 | 270.92 | 0.102386E+10 | 16058.71 | 0.00 | 0.40 | 30-APR-15:10 | 0.00 | 01-APR-00:10 | 4110.25 | 30-APR-15:10 | 4110.25 | 30-APR-15:10 | 5.91 | 30-APR-08:20 | 1024.63 | 30-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.898392E+09 | 0.231708E+09 | 294.76 | 0.884793E+09 | 13599299.38 | 0.00 | 0.31 | 22-MAY-15:10 | 0.00 | 01-MAY-02:00 | 3147.16 | 22-MAY-15:10 | 3047.97 | 22-MAY-15:10 | 186.28 | 23-MAY-14:00 | 785.34 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.202131E+10 | 0.514674E+09 | 555.70 | 0.190312E+10 | 0.118196E+09 | 0.00 | 0.36 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 | 3765.78 | 13-JUN-15:10 | 3539.54 | 13-JUN-15:10 | 498.99 | 26-JUN-17:10 | 958.50 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.282396E+10 | 0.717721E+09 | 655.97 | 0.262479E+10 | 0.199174E+09 | 0.00 | 0.42 | 22-JUL-15:10 | 0.00 | 01-JUL-00:10 | 4300.42 | 22-JUL-13:30 | 4266.47 | 22-JUL-15:10 | 429.28 | 23-JUL-16:10 | 1134.29 | 22-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.326665E+10 | 0.825374E+09 | 711.16 | 0.303918E+10 | 0.227466E+09 | 0.00 | 0.40 | 14-AUG-14:20 | 0.00 | 01-AUG-07:00 | 4132.36 | 14-AUG-14:20 | 3939.83 | 14-AUG-15:10 | 438.67 | 17-AUG-13:00 | 1024.04 | 14-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.288238E+10 | 0.729269E+09 | 586.26 | 0.274802E+10 | 0.134359E+09 | 0.00 | 0.40 | 12-SEP-14:30 | 0.00 | 01-SEP-07:50 | 4206.68 | 12-SEP-14:30 | 4019.06 | 27-SEP-13:40 | 433.88 | 12-SEP-14:20 | 1024.26 | 12-SEP-14:30 | 0.00 | 01-SEP-00:10 |
| October | 0.607242E+09 | 0.156532E+09 | 145.08 | 0.604400E+09 | 2842191.51 | 0.00 | 0.27 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 2682.69 | 03-OCT-14:10 | 2682.69 | 03-OCT-14:10 | 81.03 | 10-OCT-13:00 | 681.33 | 03-OCT-14:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.135238E+11 | 0.343921E+10 | 3219.84 | 0.128282E+11 | 0.695652E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.326665E+10 | 0.825374E+09 | 711.16 | 0.303918E+10 | 0.227466E+09 | 0.00 | 0.42 | 0.00 | 4300.42 | 4266.47 | 498.99 | 1134.29 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 2635833.07 | 694266.95 | 3.00 | 2635833.07 | -0.0 | 0.00 | 0.05 | 15-JAN-15:00 | 0.00 | 01-JAN-00:10 | 316.82 | 15-JAN-15:00 | 316.82 | 15-JAN-15:00 | 0.00 | 15-JAN-14:40 | 83.33 | 15-JAN-15:00 | 0.00 | 01-JAN-00:10 |
| February | 17203967.62 | 4517275.51 | 14.00 | 17203967.62 | -0.0 | 0.00 | 0.12 | 04-FEB-15:10 | 0.00 | 01-FEB-00:10 | 745.77 | 27-FEB-16:10 | 745.77 | 27-FEB-16:10 | 0.00 | 27-FEB-17:09 | 194.49 | 04-FEB-15:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.631569E+09 | 0.161139E+09 | 171.97 | 0.631569E+09 | -0.0 | 0.00 | 0.53 | 30-APR-16:10 | 0.00 | 01-APR-00:10 | 3614.01 | 30-APR-16:10 | 3614.01 | 30-APR-16:10 | 0.00 | 29-APR-17:40 | 883.18 | 30-APR-16:10 | 0.00 | 01-APR-00:10 |
| May | 0.569624E+09 | 0.144970E+09 | 163.93 | 0.560485E+09 | 9138993.11 | 0.00 | 0.45 | 22-MAY-15:30 | 0.00 | 01-MAY-00:10 | 3096.96 | 22-MAY-15:30 | 3017.70 | 22-MAY-15:30 | 149.42 | 23-MAY-16:02 | 756.19 | 22-MAY-15:30 | 0.00 | 01-MAY-00:10 |
| June | 0.106312E+10 | 0.267048E+09 | 275.24 | 0.101368E+10 | 49437805.92 | 0.00 | 0.55 | 13-JUN-16:25 | 0.00 | 01-JUN-00:10 | 3792.89 | 13-JUN-16:25 | 3642.25 | 13-JUN-16:40 | 489.03 | 26-JUN-17:10 | 949.98 | 13-JUN-16:40 | 0.00 | 01-JUN-00:10 |
| July | 0.156744E+10 | 0.393738E+09 | 340.17 | 0.147781E+10 | 89632456.46 | 0.00 | 0.58 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 | 3972.87 | 22-JUL-16:10 | 3972.87 | 22-JUL-16:10 | 331.38 | 23-JUL-16:10 | 1029.20 | 22-JUL-16:10 | 0.00 | 01-JUL-00:10 |
| August | 0.156772E+10 | 0.392166E+09 | 353.72 | 0.147387E+10 | 93843775.80 | 0.00 | 0.52 | 14-AUG-16:03 | 0.00 | 01-AUG-00:10 | 3556.00 | 14-AUG-16:03 | 3540.97 | 14-AUG-16:05 | 332.79 | 18-AUG-15:50 | 890.83 | 14-AUG-16:03 | 0.00 | 01-AUG-00:10 |
| September | 0.110775E+10 | 0.278005E+09 | 268.00 | 0.106060E+10 | 47148481.20 | 0.00 | 0.47 | 12-SEP-15:10 | 0.00 | 01-SEP-00:10 | 3256.40 | 12-SEP-15:10 | 3051.19 | 13-SEP-16:08 | 304.92 | 12-SEP-14:20 | 788.13 | 12-SEP-15:10 | 0.00 | 01-SEP-00:10 |
| October | 0.205954E+09 | 53172092.65 | 73.44 | 0.205569E+09 | 385614.82 | 0.00 | 0.32 | 07-OCT-15:20 | 0.00 | 01-OCT-00:10 | 2060.51 | 07-OCT-15:20 | 2060.51 | 07-OCT-15:20 | 41.64 | 10-OCT-14:30 | 522.71 | 07-OCT-15:20 | 0.00 | 01-OCT-00:10 |
| November | 1859155.39 | 490675.82 | 4.67 | 1859155.39 | 0.00 | 0.00 | 0.04 | 11-NOV-14:20 | 0.00 | 01-NOV-00:10 | 226.78 | 11-NOV-14:20 | 226.78 | 11-NOV-14:20 | 0.00 | 11-NOV-14:40 | 59.73 | 11-NOV-14:20 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.673488E+10 | 0.169594E+10 | 1668.15 | 0.644529E+10 | 0.289587E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.156772E+10 | 0.393738E+09 | 353.72 | 0.147781E+10 | 93843775.80 | 0.00 | 0.58 | 0.00 | 3972.87 | 3972.87 | 489.03 | 1029.20 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.185146E+09 | 47573801.91 | 72.56 | 0.185146E+09 | -0.0 | 0.00 | 0.41 | 30-APR-17:20 | 0.00 | 01-APR-00:10 | 2461.05 | 30-APR-17:20 | 2461.05 | 30-APR-17:20 | 0.00 | 28-APR-16:00 | 614.15 | 30-APR-17:20 | 0.00 | 01-APR-00:10 |
| May | 0.248739E+09 | 63318410.45 | 93.15 | 0.241052E+09 | 7687687.25 | 0.00 | 0.39 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 | 2384.55 | 22-MAY-16:10 | 2311.41 | 22-MAY-16:05 | 143.35 | 23-MAY-16:13 | 587.62 | 22-MAY-16:10 | 0.00 | 01-MAY-00:10 |
| June | 0.703084E+09 | 0.176745E+09 | 226.50 | 0.662545E+09 | 40538670.45 | 0.00 | 0.55 | 13-JUN-17:10 | 0.00 | 01-JUN-00:10 | 3430.87 | 13-JUN-17:10 | 3270.46 | 13-JUN-17:10 | 462.93 | 26-JUN-17:10 | 858.45 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.103537E+10 | 0.261636E+09 | 292.83 | 0.967624E+09 | 67747763.00 | 0.00 | 0.55 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 3337.21 | 22-JUL-17:50 | 3337.21 | 22-JUL-17:50 | 293.45 | 24-JUL-16:12 | 882.89 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.731085E+09 | 0.184968E+09 | 275.94 | 0.678723E+09 | 52361890.71 | 0.00 | 0.44 | 14-AUG-17:10 | 0.00 | 01-AUG-00:10 | 2659.77 | 14-AUG-16:23 | 2644.20 | 14-AUG-17:10 | 282.55 | 18-AUG-16:03 | 680.90 | 14-AUG-17:10 | 0.00 | 01-AUG-00:10 |
| September | 0.245300E+09 | 62271307.92 | 112.70 | 0.228602E+09 | 16698072.20 | 0.00 | 0.34 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 | 2065.04 | 13-SEP-16:30 | 1927.93 | 13-SEP-16:30 | 195.34 | 10-SEP-16:20 | 510.14 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 |
| October | 817147.60 | 216851.54 | 2.54 | 817147.60 | 0.00 | 0.00 | 0.03 | 07-OCT-17:00 | 0.00 | 01-OCT-00:10 | 158.64 | 07-OCT-17:00 | 158.64 | 07-OCT-17:00 | 0.00 | 07-OCT-16:00 | 42.10 | 07-OCT-17:00 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.314954E+10 | 0.796728E+09 | 1076.22 | 0.296451E+10 | 0.185034E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.103537E+10 | 0.261636E+09 | 292.83 | 0.967624E+09 | 67747763.00 | 0.00 | 0.55 | 0.00 | 3430.87 | 3337.21 | 462.93 | 882.89 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 1869198.16 | 492119.57 | 2.50 | 1869198.16 | 0.00 | 0.00 | 0.06 | 15-JAN-13:10 | 0.00 | 01-JAN-00:10 | 319.16 | 15-JAN-13:10 | 319.16 | 15-JAN-13:10 | 0.00 | 15-JAN-13:30 | 83.85 | 15-JAN-13:10 | 0.00 | 01-JAN-00:10 |
| February | 4890999.08 | 1284422.67 | 4.83 | 4890999.08 | -0.0 | 0.00 | 0.10 | 04-FEB-14:20 | 0.00 | 01-FEB-00:10 | 535.54 | 04-FEB-14:20 | 535.54 | 04-FEB-14:20 | 0.00 | 04-FEB-14:10 | 140.18 | 04-FEB-14:20 | 0.00 | 01-FEB-00:10 |
| March | 1112933.69 | 293356.47 | 2.33 | 1112933.69 | 0.00 | 0.00 | 0.04 | 25-MAR-12:00 | 0.00 | 01-MAR-00:10 | 201.48 | 25-MAR-12:00 | 201.48 | 25-MAR-12:00 | 0.00 | 25-MAR-11:40 | 53.08 | 25-MAR-12:00 | 0.00 | 01-MAR-00:10 |
| April | 0.624582E+09 | 0.158858E+09 | 193.25 | 0.624582E+09 | 70.25 | 0.00 | 0.55 | 30-APR-14:10 | 0.00 | 01-APR-00:10 | 3070.01 | 30-APR-14:00 | 3070.01 | 30-APR-14:00 | 0.12 | 28-APR-09:00 | 744.90 | 30-APR-14:10 | 0.00 | 01-APR-00:10 |
| May | 0.526112E+09 | 0.133696E+09 | 175.99 | 0.517957E+09 | 8154152.71 | 0.00 | 0.47 | 22-MAY-14:20 | 0.00 | 01-MAY-00:10 | 2624.66 | 22-MAY-14:30 | 2562.52 | 22-MAY-14:20 | 134.22 | 23-MAY-14:00 | 638.86 | 22-MAY-14:20 | 0.00 | 01-MAY-00:10 |
| June | 0.101119E+10 | 0.253213E+09 | 294.28 | 0.962898E+09 | 48288362.65 | 0.00 | 0.56 | 13-JUN-14:10 | 0.00 | 01-JUN-00:10 | 3158.27 | 13-JUN-13:30 | 2987.07 | 13-JUN-14:10 | 367.93 | 26-JUN-17:10 | 769.61 | 13-JUN-14:10 | 0.00 | 01-JUN-00:10 |
| July | 0.149398E+10 | 0.373609E+09 | 368.77 | 0.140782E+10 | 86156883.15 | 0.00 | 0.64 | 22-JUL-13:30 | 0.00 | 01-JUL-00:10 | 3578.47 | 22-JUL-13:30 | 3563.81 | 22-JUL-13:30 | 290.40 | 23-JUL-16:10 | 903.70 | 22-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 0.161424E+10 | 0.401051E+09 | 375.27 | 0.151619E+10 | 98051221.64 | 0.00 | 0.55 | 14-AUG-13:10 | 0.00 | 01-AUG-00:10 | 3114.95 | 14-AUG-13:10 | 2954.18 | 14-AUG-14:30 | 305.58 | 17-AUG-09:40 | 746.19 | 14-AUG-14:20 | 0.00 | 01-AUG-00:10 |
| September | 0.115454E+10 | 0.288601E+09 | 293.33 | 0.110566E+10 | 48874304.42 | 0.00 | 0.51 | 12-SEP-14:10 | 0.00 | 01-SEP-00:10 | 2925.06 | 12-SEP-14:10 | 2709.44 | 13-SEP-14:10 | 280.57 | 12-SEP-14:10 | 699.94 | 12-SEP-14:10 | 0.00 | 01-SEP-00:10 |
| October | 0.206579E+09 | 53250066.23 | 82.50 | 0.206288E+09 | 290741.58 | 0.00 | 0.31 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1654.57 | 07-OCT-15:10 | 1654.57 | 07-OCT-15:10 | 30.93 | 10-OCT-14:10 | 419.80 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 813964.05 | 214684.99 | 1.83 | 813964.05 | 0.00 | 0.00 | 0.04 | 11-NOV-13:40 | 0.00 | 01-NOV-00:10 | 182.80 | 11-NOV-13:40 | 182.80 | 11-NOV-13:40 | 0.00 | 11-NOV-13:40 | 48.16 | 11-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.663991E+10 | 0.166456E+10 | 1794.89 | 0.635009E+10 | 0.289816E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.161424E+10 | 0.401051E+09 | 375.27 | 0.151619E+10 | 98051221.64 | 0.00 | 0.64 | 0.00 | 3578.47 | 3563.81 | 367.93 | 903.70 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.145274E+09 | 37405290.90 | 81.32 | 0.145274E+09 | -0.0 | 0.00 | 0.35 | 30-APR-16:20 | 0.00 | 01-APR-00:10 | 1655.99 | 30-APR-16:20 | 1655.99 | 30-APR-16:20 | 0.00 | 29-APR-16:05 | 416.89 | 30-APR-16:20 | 0.00 | 01-APR-00:10 |
| May | 0.187702E+09 | 47814454.50 | 100.67 | 0.181051E+09 | 6651365.98 | 0.00 | 0.36 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 | 1721.35 | 22-MAY-15:10 | 1650.88 | 22-MAY-15:10 | 105.67 | 23-MAY-09:50 | 425.75 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.634759E+09 | 0.159443E+09 | 256.15 | 0.595617E+09 | 39142232.35 | 0.00 | 0.49 | 13-JUN-16:12 | 0.00 | 01-JUN-00:10 | 2425.37 | 13-JUN-16:12 | 2274.71 | 13-JUN-16:15 | 326.90 | 26-JUN-17:10 | 610.19 | 13-JUN-16:12 | 0.00 | 01-JUN-00:10 |
| July | 0.935490E+09 | 0.236076E+09 | 344.09 | 0.872452E+09 | 63037694.57 | 0.00 | 0.53 | 22-JUL-16:20 | 0.00 | 01-JUL-00:10 | 2534.92 | 22-JUL-16:20 | 2534.92 | 22-JUL-16:20 | 226.44 | 23-JUL-16:10 | 663.05 | 22-JUL-16:20 | 0.00 | 01-JUL-00:10 |
| August | 0.742958E+09 | 0.187835E+09 | 318.44 | 0.687200E+09 | 55758061.15 | 0.00 | 0.39 | 14-AUG-16:12 | 0.00 | 01-AUG-00:10 | 1894.93 | 14-AUG-16:12 | 1862.45 | 14-AUG-16:23 | 238.90 | 17-AUG-09:30 | 484.64 | 14-AUG-16:12 | 0.00 | 01-AUG-00:10 |
| September | 0.201061E+09 | 51079209.76 | 126.28 | 0.185680E+09 | 15381384.66 | 0.00 | 0.29 | 13-SEP-16:05 | 0.00 | 01-SEP-00:10 | 1382.66 | 13-SEP-16:05 | 1278.00 | 13-SEP-16:05 | 153.42 | 12-SEP-14:20 | 343.72 | 13-SEP-16:05 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.284724E+10 | 0.719653E+09 | 1226.94 | 0.266727E+10 | 0.179971E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.935490E+09 | 0.236076E+09 | 344.09 | 0.872452E+09 | 63037694.57 | 0.00 | 0.53 | 0.00 | 2534.92 | 2534.92 | 326.90 | 663.05 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 72867359.43 | 18821883.52 | 46.62 | 72867359.43 | 0.00 | 0.00 | 0.30 | 30-APR-16:30 | 0.00 | 01-APR-00:10 | 1336.86 | 30-APR-16:30 | 1336.86 | 30-APR-16:30 | 0.00 | 30-APR-15:10 | 339.53 | 30-APR-16:30 | 0.00 | 01-APR-00:10 |
| May | 97779366.42 | 24976255.80 | 62.42 | 93243964.86 | 4535401.56 | 0.00 | 0.28 | 22-MAY-15:20 | 0.00 | 01-MAY-00:10 | 1323.69 | 22-MAY-15:20 | 1265.06 | 22-MAY-15:20 | 77.31 | 23-MAY-16:30 | 330.86 | 22-MAY-15:20 | 0.00 | 01-MAY-00:10 |
| June | 0.437300E+09 | 0.110477E+09 | 227.30 | 0.405531E+09 | 31768345.93 | 0.00 | 0.44 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 2055.86 | 13-JUN-17:00 | 1931.84 | 13-JUN-17:00 | 281.21 | 26-JUN-17:10 | 524.79 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.664905E+09 | 0.168982E+09 | 309.53 | 0.614330E+09 | 50575678.49 | 0.00 | 0.46 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 2126.62 | 22-JUL-18:00 | 2126.62 | 22-JUL-18:00 | 201.45 | 23-JUL-18:00 | 570.75 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.459338E+09 | 0.116839E+09 | 285.03 | 0.421786E+09 | 37551593.58 | 0.00 | 0.34 | 14-AUG-17:20 | 0.00 | 01-AUG-00:10 | 1580.32 | 14-AUG-16:23 | 1571.18 | 14-AUG-17:15 | 177.42 | 17-AUG-15:10 | 410.55 | 14-AUG-17:20 | 0.00 | 01-AUG-00:10 |
| September | 0.103295E+09 | 26301219.97 | 82.03 | 94317195.70 | 8978025.17 | 0.00 | 0.25 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 | 1152.52 | 13-SEP-16:30 | 1060.91 | 13-SEP-16:30 | 109.55 | 12-SEP-14:30 | 288.07 | 13-SEP-16:30 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.183548E+10 | 0.466396E+09 | 1012.93 | 0.170208E+10 | 0.133409E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.664905E+09 | 0.168982E+09 | 309.53 | 0.614330E+09 | 50575678.49 | 0.00 | 0.46 | 0.00 | 2126.62 | 2126.62 | 281.21 | 570.75 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 74784678.07 | 19317061.30 | 48.61 | 74784678.07 | 0.00 | 0.00 | 0.30 | 30-APR-16:30 | 0.00 | 01-APR-00:10 | 1329.77 | 30-APR-16:30 | 1329.77 | 30-APR-16:30 | 0.00 | 30-APR-15:50 | 337.67 | 30-APR-16:30 | 0.00 | 01-APR-00:10 |
| May | 99501676.40 | 25415184.77 | 63.58 | 94917442.43 | 4584233.97 | 0.00 | 0.29 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 | 1329.39 | 22-MAY-15:10 | 1270.56 | 22-MAY-15:10 | 78.24 | 23-MAY-14:10 | 332.10 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.440265E+09 | 0.111221E+09 | 228.76 | 0.408396E+09 | 31868574.80 | 0.00 | 0.43 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 | 2033.42 | 13-JUN-17:00 | 1910.45 | 13-JUN-17:00 | 277.09 | 26-JUN-17:10 | 519.12 | 13-JUN-17:00 | 0.00 | 01-JUN-00:10 |
| July | 0.666604E+09 | 0.169399E+09 | 314.17 | 0.616126E+09 | 50477731.75 | 0.00 | 0.46 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 | 2104.24 | 22-JUL-18:00 | 2104.24 | 22-JUL-18:00 | 199.12 | 23-JUL-18:00 | 564.81 | 22-JUL-18:00 | 0.00 | 01-JUL-00:10 |
| August | 0.468061E+09 | 0.119034E+09 | 287.62 | 0.429907E+09 | 38153476.32 | 0.00 | 0.34 | 14-AUG-17:20 | 0.00 | 01-AUG-00:10 | 1567.21 | 14-AUG-16:23 | 1554.85 | 14-AUG-17:10 | 177.19 | 17-AUG-15:10 | 406.12 | 14-AUG-17:10 | 0.00 | 01-AUG-00:10 |
| September | 0.106311E+09 | 27066645.71 | 83.57 | 97098643.69 | 9212450.95 | 0.00 | 0.25 | 13-SEP-16:12 | 0.00 | 01-SEP-00:10 | 1144.52 | 13-SEP-16:12 | 1052.32 | 13-SEP-16:15 | 112.23 | 12-SEP-14:30 | 286.00 | 13-SEP-16:12 | 0.00 | 01-SEP-00:10 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.185553E+10 | 0.471453E+09 | 1026.31 | 0.172123E+10 | 0.134296E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.666604E+09 | 0.169399E+09 | 314.17 | 0.616126E+09 | 50477731.75 | 0.00 | 0.46 | 0.00 | 2104.24 | 2104.24 | 277.09 | 564.81 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 3758290.36 | 986023.43 | 3.92 | 3758290.36 | 0.00 | 0.00 | 0.08 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 | 420.74 | 15-JAN-13:40 | 420.74 | 15-JAN-13:40 | 0.00 | 15-JAN-13:20 | 110.16 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 |
| February | 12318837.35 | 3233412.74 | 13.83 | 12318837.35 | 0.00 | 0.00 | 0.15 | 04-FEB-14:30 | 0.00 | 01-FEB-00:10 | 743.37 | 04-FEB-14:30 | 743.37 | 04-FEB-14:30 | 0.00 | 04-FEB-15:00 | 193.30 | 04-FEB-14:30 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.479463E+09 | 0.122585E+09 | 177.39 | 0.479463E+09 | 0.00 | 0.00 | 0.50 | 30-APR-15:10 | 0.00 | 01-APR-00:10 | 2687.89 | 30-APR-14:20 | 2687.89 | 30-APR-14:20 | 0.00 | 29-APR-13:50 | 659.54 | 30-APR-15:10 | 0.00 | 01-APR-00:10 |
| May | 0.389649E+09 | 99613410.50 | 163.67 | 0.382778E+09 | 6870292.16 | 0.00 | 0.41 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 | 2226.49 | 22-MAY-15:10 | 2162.21 | 22-MAY-14:40 | 120.85 | 23-MAY-14:00 | 546.90 | 22-MAY-15:10 | 0.00 | 01-MAY-00:10 |
| June | 0.803821E+09 | 0.202649E+09 | 297.39 | 0.761187E+09 | 42633998.10 | 0.00 | 0.49 | 13-JUN-14:20 | 0.00 | 01-JUN-00:10 | 2675.97 | 13-JUN-14:10 | 2525.40 | 13-JUN-14:20 | 323.44 | 26-JUN-17:10 | 662.37 | 13-JUN-15:10 | 0.00 | 01-JUN-00:10 |
| July | 0.121397E+10 | 0.305653E+09 | 371.34 | 0.113717E+10 | 76802240.13 | 0.00 | 0.55 | 22-JUL-13:50 | 0.00 | 01-JUL-00:10 | 3016.58 | 22-JUL-13:40 | 3003.17 | 22-JUL-13:50 | 263.16 | 23-JUL-16:10 | 775.38 | 22-JUL-15:10 | 0.00 | 01-JUL-00:10 |
| August | 0.132583E+10 | 0.331523E+09 | 381.58 | 0.124041E+10 | 85418128.63 | 0.00 | 0.49 | 14-AUG-14:30 | 0.00 | 01-AUG-00:10 | 2698.81 | 14-AUG-14:20 | 2588.64 | 14-AUG-15:10 | 269.51 | 17-AUG-13:00 | 659.07 | 14-AUG-15:10 | 0.00 | 01-AUG-00:10 |
| September | 0.986470E+09 | 0.247558E+09 | 301.46 | 0.941901E+09 | 44568685.99 | 0.00 | 0.47 | 12-SEP-14:30 | 0.00 | 01-SEP-00:10 | 2615.68 | 12-SEP-14:30 | 2422.80 | 13-SEP-14:10 | 258.44 | 12-SEP-14:20 | 630.15 | 12-SEP-14:30 | 0.00 | 01-SEP-00:10 |
| October | 0.185706E+09 | 47941681.48 | 81.67 | 0.185371E+09 | 335084.36 | 0.00 | 0.30 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1564.13 | 07-OCT-15:10 | 1564.13 | 07-OCT-15:10 | 32.49 | 10-OCT-14:20 | 397.53 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 3042810.39 | 800119.43 | 6.15 | 3042810.39 | -0.0 | 0.00 | 0.07 | 11-NOV-13:40 | 0.00 | 01-NOV-00:10 | 361.44 | 11-NOV-13:40 | 361.44 | 11-NOV-13:40 | 0.00 | 11-NOV-12:50 | 94.71 | 11-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 20417.49 | 5434.51 | 0.33 | 20417.49 | 0.00 | 0.00 | 0.00 | 18-DEC-14:30 | 0.00 | 01-DEC-00:10 | 19.55 | 18-DEC-14:30 | 19.55 | 18-DEC-14:30 | 0.00 | 18-DEC-14:10 | 5.20 | 18-DEC-14:30 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.540405E+10 | 0.136255E+10 | 1798.72 | 0.514742E+10 | 0.256628E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.132583E+10 | 0.331523E+09 | 381.58 | 0.124041E+10 | 85418128.63 | 0.00 | 0.55 | 0.00 | 3016.58 | 3003.17 | 323.44 | 775.38 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
| January | 3861602.68 | 1012816.56 | 4.08 | 3861602.68 | 0.00 | 0.00 | 0.09 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 | 433.28 | 15-JAN-13:40 | 433.28 | 15-JAN-13:40 | 0.00 | 15-JAN-13:40 | 113.39 | 15-JAN-13:40 | 0.00 | 01-JAN-00:10 |
| February | 12287534.58 | 3224533.26 | 13.67 | 12287534.58 | -0.0 | 0.00 | 0.15 | 04-FEB-14:30 | 0.00 | 01-FEB-00:10 | 751.27 | 04-FEB-14:30 | 751.27 | 04-FEB-14:30 | 0.00 | 04-FEB-14:20 | 195.28 | 04-FEB-14:30 | 0.00 | 01-FEB-00:10 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
| April | 0.487218E+09 | 0.124537E+09 | 179.75 | 0.487218E+09 | 0.00 | 0.00 | 0.50 | 30-APR-14:20 | 0.00 | 01-APR-00:10 | 2697.79 | 30-APR-14:20 | 2697.79 | 30-APR-14:20 | 0.00 | 29-APR-13:50 | 660.12 | 30-APR-14:20 | 0.00 | 01-APR-00:10 |
| May | 0.395800E+09 | 0.101157E+09 | 165.33 | 0.388928E+09 | 6871764.97 | 0.00 | 0.41 | 22-MAY-14:40 | 0.00 | 01-MAY-00:10 | 2232.37 | 22-MAY-14:40 | 2171.11 | 22-MAY-14:40 | 121.17 | 23-MAY-14:00 | 548.09 | 22-MAY-14:40 | 0.00 | 01-MAY-00:10 |
| June | 0.808330E+09 | 0.203734E+09 | 298.42 | 0.765645E+09 | 42685127.45 | 0.00 | 0.49 | 13-JUN-14:10 | 0.00 | 01-JUN-00:10 | 2682.28 | 13-JUN-14:10 | 2531.62 | 13-JUN-14:10 | 320.39 | 26-JUN-17:10 | 662.47 | 13-JUN-14:20 | 0.00 | 01-JUN-00:10 |
| July | 0.121740E+10 | 0.306429E+09 | 373.69 | 0.114071E+10 | 76682528.88 | 0.00 | 0.56 | 22-JUL-13:40 | 0.00 | 01-JUL-00:10 | 3028.01 | 22-JUL-13:40 | 3012.44 | 22-JUL-13:50 | 262.31 | 23-JUL-16:10 | 774.28 | 22-JUL-13:40 | 0.00 | 01-JUL-00:10 |
| August | 0.133468E+10 | 0.333585E+09 | 382.92 | 0.124886E+10 | 85827379.55 | 0.00 | 0.49 | 14-AUG-14:30 | 0.00 | 01-AUG-00:10 | 2706.10 | 14-AUG-14:20 | 2587.84 | 14-AUG-15:10 | 270.05 | 17-AUG-13:00 | 659.90 | 14-AUG-14:30 | 0.00 | 01-AUG-00:10 |
| September | 0.996566E+09 | 0.250015E+09 | 302.24 | 0.951759E+09 | 44806802.93 | 0.00 | 0.47 | 12-SEP-14:20 | 0.00 | 01-SEP-00:10 | 2625.48 | 12-SEP-14:20 | 2431.40 | 13-SEP-14:10 | 258.49 | 12-SEP-14:10 | 631.84 | 12-SEP-14:20 | 0.00 | 01-SEP-00:10 |
| October | 0.188992E+09 | 48772315.62 | 82.00 | 0.188654E+09 | 338500.42 | 0.00 | 0.30 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 | 1564.23 | 07-OCT-15:10 | 1564.23 | 07-OCT-15:10 | 32.73 | 10-OCT-14:10 | 397.41 | 07-OCT-15:10 | 0.00 | 01-OCT-00:10 |
| November | 3198715.28 | 840916.78 | 6.41 | 3198715.28 | -0.0 | 0.00 | 0.08 | 11-NOV-13:40 | 0.00 | 01-NOV-00:10 | 377.66 | 11-NOV-13:40 | 377.66 | 11-NOV-13:40 | 0.00 | 11-NOV-13:50 | 98.90 | 11-NOV-13:40 | 0.00 | 01-NOV-00:10 |
| December | 42809.93 | 11388.68 | 0.33 | 42809.93 | 0.00 | 0.00 | 0.01 | 18-DEC-14:00 | 0.00 | 01-DEC-00:10 | 37.94 | 18-DEC-14:00 | 37.94 | 18-DEC-14:00 | 0.00 | 18-DEC-14:20 | 10.09 | 18-DEC-14:00 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.544838E+10 | 0.137332E+10 | 1808.83 | 0.519116E+10 | 0.257212E+09 | 0.00 | ||||||||||||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Maximum of Months | 0.133468E+10 | 0.333585E+09 | 382.92 | 0.124886E+10 | 85827379.55 | 0.00 | 0.56 | 0.00 | 3028.01 | 3012.44 | 320.39 | 774.28 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 173.05 | 159.89 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 216.81 | 154.41 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 109.80 | 126.77 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 309.30 | 108.12 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 237.43 | 94.87 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 228.12 | 76.28 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 262.48 | 72.87 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 320.30 | 80.96 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 382.45 | 103.23 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 226.21 | 125.19 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 151.59 | 146.69 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 115.05 | 182.63 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 227.37 | 119.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 109.80 | 72.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 382.45 | 182.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.42 | 12.88 | 26.54 | 24.48 | 113.40 | 0.00 | 0.00 | 0.00 |
| February | 69.74 | 29.62 | 40.12 | 56.48 | 106.44 | 0.00 | 0.00 | 0.00 |
| March | 62.85 | 12.08 | 50.77 | 42.13 | 83.81 | 0.00 | 0.00 | 0.00 |
| April | 147.89 | 58.59 | 89.30 | 157.51 | 69.82 | 0.00 | 0.00 | 0.00 |
| May | 173.46 | 70.33 | 103.14 | 183.22 | 59.57 | 0.00 | 0.00 | 0.00 |
| June | 187.69 | 77.44 | 110.24 | 210.53 | 48.32 | 0.00 | 0.00 | 0.00 |
| July | 191.15 | 84.33 | 106.82 | 221.76 | 46.19 | 0.00 | 0.00 | 0.00 |
| August | 160.43 | 69.38 | 91.04 | 186.11 | 52.22 | 0.00 | 0.00 | 0.00 |
| September | 129.86 | 58.69 | 71.16 | 143.16 | 68.04 | 0.00 | 0.00 | 0.00 |
| October | 68.95 | 24.88 | 44.08 | 60.70 | 84.12 | 0.00 | 0.00 | 0.00 |
| November | 37.32 | 10.99 | 26.34 | 23.46 | 101.39 | 0.00 | 0.00 | 0.00 |
| December | 20.96 | 4.36 | 16.60 | 7.59 | 127.41 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 107.59 | 42.81 | 64.78 | 109.94 | 79.93 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20.96 | 4.36 | 16.60 | 7.59 | 46.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 191.15 | 84.33 | 110.24 | 221.76 | 127.41 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.42 | 12.88 | 26.54 | 25.30 | 111.42 | 0.00 | 0.00 | 0.00 |
| February | 69.74 | 29.62 | 40.12 | 57.69 | 104.53 | 0.00 | 0.00 | 0.00 |
| March | 62.85 | 12.08 | 50.77 | 42.77 | 83.17 | 0.00 | 0.00 | 0.00 |
| April | 147.89 | 58.59 | 89.30 | 161.50 | 66.83 | 0.00 | 0.00 | 0.00 |
| May | 173.46 | 70.33 | 103.14 | 186.77 | 57.17 | 0.00 | 0.00 | 0.00 |
| June | 187.69 | 77.44 | 110.24 | 213.13 | 46.54 | 0.00 | 0.00 | 0.00 |
| July | 191.15 | 84.33 | 106.82 | 223.66 | 45.00 | 0.00 | 0.00 | 0.00 |
| August | 160.43 | 69.38 | 91.04 | 188.83 | 49.97 | 0.00 | 0.00 | 0.00 |
| September | 129.86 | 58.69 | 71.16 | 148.10 | 62.30 | 0.00 | 0.00 | 0.00 |
| October | 68.95 | 24.88 | 44.08 | 64.03 | 79.11 | 0.00 | 0.00 | 0.00 |
| November | 37.32 | 10.99 | 26.34 | 24.34 | 99.34 | 0.00 | 0.00 | 0.00 |
| December | 20.96 | 4.36 | 16.60 | 7.89 | 126.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 107.59 | 42.81 | 64.78 | 112.18 | 77.50 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20.96 | 4.36 | 16.60 | 7.89 | 45.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 191.15 | 84.33 | 110.24 | 223.66 | 126.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.91 | 177.64 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 8.64 | 164.06 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 26.71 | 130.78 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 79.52 | 101.47 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 99.98 | 81.80 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 130.29 | 67.23 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 127.66 | 64.60 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 97.76 | 73.33 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 65.78 | 96.25 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 26.33 | 122.34 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.62 | 154.14 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.19 | 193.90 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 56.10 | 118.75 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.19 | 64.60 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 130.29 | 193.90 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 177.69 | 143.02 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 222.17 | 138.45 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 114.41 | 114.41 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 307.52 | 108.59 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 234.78 | 97.60 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 224.91 | 80.29 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 257.57 | 78.84 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 316.00 | 88.60 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 379.26 | 110.02 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 225.61 | 126.87 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 153.77 | 137.54 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 118.54 | 161.43 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 227.31 | 115.35 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 114.41 | 78.84 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 379.26 | 161.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 40.20 | 16.07 | 24.13 | 25.91 | 99.24 | 0.00 | 0.00 | 0.00 |
| February | 60.32 | 22.37 | 37.95 | 43.50 | 92.85 | 0.00 | 0.00 | 0.00 |
| March | 62.82 | 12.34 | 50.48 | 45.06 | 74.37 | 0.00 | 0.00 | 0.00 |
| April | 168.23 | 78.85 | 89.38 | 181.99 | 66.81 | 0.00 | 0.00 | 0.00 |
| May | 177.25 | 77.21 | 100.04 | 185.88 | 59.01 | 0.00 | 0.00 | 0.00 |
| June | 175.68 | 70.25 | 105.43 | 192.28 | 49.18 | 0.00 | 0.00 | 0.00 |
| July | 179.35 | 76.29 | 103.06 | 201.77 | 47.98 | 0.00 | 0.00 | 0.00 |
| August | 169.97 | 81.24 | 88.73 | 194.90 | 53.99 | 0.00 | 0.00 | 0.00 |
| September | 152.48 | 80.89 | 71.59 | 169.07 | 69.04 | 0.00 | 0.00 | 0.00 |
| October | 74.55 | 31.32 | 43.23 | 66.83 | 83.26 | 0.00 | 0.00 | 0.00 |
| November | 38.34 | 12.99 | 25.35 | 23.95 | 92.38 | 0.00 | 0.00 | 0.00 |
| December | 28.45 | 10.55 | 17.90 | 16.02 | 108.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 110.80 | 47.59 | 63.20 | 112.50 | 74.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28.45 | 10.55 | 17.90 | 16.02 | 47.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 179.35 | 81.24 | 105.43 | 201.77 | 108.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 40.20 | 16.07 | 24.13 | 24.52 | 109.24 | 0.00 | 0.00 | 0.00 |
| February | 60.32 | 22.37 | 37.95 | 41.44 | 101.52 | 0.00 | 0.00 | 0.00 |
| March | 62.82 | 12.34 | 50.48 | 42.40 | 81.59 | 0.00 | 0.00 | 0.00 |
| April | 168.23 | 78.85 | 89.38 | 186.28 | 63.40 | 0.00 | 0.00 | 0.00 |
| May | 177.25 | 77.21 | 100.04 | 190.66 | 54.59 | 0.00 | 0.00 | 0.00 |
| June | 175.68 | 70.25 | 105.43 | 197.01 | 44.51 | 0.00 | 0.00 | 0.00 |
| July | 179.35 | 76.29 | 103.06 | 206.70 | 43.09 | 0.00 | 0.00 | 0.00 |
| August | 169.97 | 81.24 | 88.73 | 200.19 | 47.37 | 0.00 | 0.00 | 0.00 |
| September | 152.48 | 80.89 | 71.59 | 175.40 | 59.79 | 0.00 | 0.00 | 0.00 |
| October | 74.55 | 31.32 | 43.23 | 70.15 | 76.98 | 0.00 | 0.00 | 0.00 |
| November | 38.34 | 12.99 | 25.35 | 23.54 | 96.45 | 0.00 | 0.00 | 0.00 |
| December | 28.45 | 10.55 | 17.90 | 14.75 | 121.38 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 110.80 | 47.59 | 63.20 | 114.68 | 74.87 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28.45 | 10.55 | 17.90 | 14.75 | 43.09 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 179.35 | 81.24 | 105.43 | 206.70 | 121.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.88 | 177.64 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 8.55 | 163.77 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 26.60 | 130.68 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 78.44 | 101.42 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 99.25 | 81.41 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 129.99 | 66.42 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 126.73 | 64.27 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 96.55 | 73.35 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 64.05 | 97.02 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 25.92 | 122.26 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.57 | 154.10 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.18 | 194.10 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 55.54 | 118.65 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.18 | 64.27 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 129.99 | 194.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.69 | 181.21 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 8.13 | 167.07 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 25.85 | 133.55 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 79.14 | 102.62 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 99.71 | 82.62 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 129.90 | 68.22 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 127.08 | 65.62 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 97.24 | 74.62 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 64.64 | 98.93 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 25.52 | 125.28 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.33 | 157.28 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.14 | 197.93 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 55.60 | 121.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.14 | 65.62 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 129.90 | 197.93 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.69 | 181.21 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 8.13 | 167.05 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 25.85 | 133.54 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 79.06 | 102.64 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 99.66 | 82.61 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 129.92 | 68.15 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 126.98 | 65.65 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 97.15 | 74.67 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 64.46 | 99.14 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 25.50 | 125.30 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.33 | 157.28 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.14 | 197.94 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 55.56 | 121.05 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.14 | 65.65 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 129.92 | 197.94 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 171.80 | 163.56 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 215.56 | 157.76 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 108.55 | 129.62 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 307.73 | 110.55 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 235.97 | 97.17 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 227.15 | 77.97 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 261.91 | 74.18 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 319.97 | 82.10 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 381.43 | 105.65 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 224.45 | 129.96 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 150.55 | 150.25 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 114.31 | 186.58 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 226.27 | 121.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 108.55 | 74.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 381.43 | 186.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 172.10 | 162.69 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 215.90 | 156.92 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 108.79 | 129.03 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 307.49 | 110.69 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 235.55 | 97.54 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 226.72 | 78.33 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 261.49 | 74.56 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 319.65 | 82.46 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 381.16 | 106.00 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 224.32 | 130.18 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 150.68 | 149.74 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 114.50 | 185.63 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 226.18 | 121.81 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 108.79 | 74.56 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 381.16 | 185.63 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 169.62 | 167.41 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 212.31 | 162.95 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 105.36 | 134.69 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 298.44 | 122.05 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 226.71 | 107.78 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 220.41 | 83.95 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 257.65 | 77.17 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 317.07 | 83.83 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 379.05 | 106.88 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 222.42 | 132.88 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 149.07 | 152.95 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 113.27 | 189.52 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 222.27 | 126.66 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 105.36 | 77.17 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 379.05 | 189.52 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.42 | 12.88 | 26.54 | 23.10 | 119.15 | 0.00 | 0.00 | 0.00 |
| February | 69.74 | 29.62 | 40.12 | 54.16 | 112.58 | 0.00 | 0.00 | 0.00 |
| March | 62.85 | 12.08 | 50.77 | 39.24 | 89.15 | 0.00 | 0.00 | 0.00 |
| April | 147.89 | 58.59 | 89.30 | 149.90 | 78.69 | 0.00 | 0.00 | 0.00 |
| May | 173.46 | 70.33 | 103.14 | 174.97 | 67.28 | 0.00 | 0.00 | 0.00 |
| June | 187.69 | 77.44 | 110.24 | 204.72 | 53.17 | 0.00 | 0.00 | 0.00 |
| July | 191.15 | 84.33 | 106.82 | 218.06 | 48.89 | 0.00 | 0.00 | 0.00 |
| August | 160.43 | 69.38 | 91.04 | 183.71 | 54.10 | 0.00 | 0.00 | 0.00 |
| September | 129.86 | 58.69 | 71.16 | 141.04 | 70.54 | 0.00 | 0.00 | 0.00 |
| October | 68.95 | 24.88 | 44.08 | 58.46 | 89.42 | 0.00 | 0.00 | 0.00 |
| November | 37.32 | 10.99 | 26.34 | 22.32 | 105.98 | 0.00 | 0.00 | 0.00 |
| December | 20.96 | 4.36 | 16.60 | 7.14 | 132.59 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 107.59 | 42.81 | 64.78 | 106.58 | 84.99 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20.96 | 4.36 | 16.60 | 7.14 | 48.89 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 191.15 | 84.33 | 110.24 | 218.06 | 132.59 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.42 | 12.88 | 26.54 | 24.36 | 116.42 | 0.00 | 0.00 | 0.00 |
| February | 69.74 | 29.62 | 40.12 | 56.08 | 109.69 | 0.00 | 0.00 | 0.00 |
| March | 62.85 | 12.08 | 50.77 | 40.25 | 88.06 | 0.00 | 0.00 | 0.00 |
| April | 147.89 | 58.59 | 89.30 | 154.41 | 74.40 | 0.00 | 0.00 | 0.00 |
| May | 173.46 | 70.33 | 103.14 | 177.65 | 65.32 | 0.00 | 0.00 | 0.00 |
| June | 187.69 | 77.44 | 110.24 | 205.64 | 52.76 | 0.00 | 0.00 | 0.00 |
| July | 191.15 | 84.33 | 106.82 | 219.10 | 48.50 | 0.00 | 0.00 | 0.00 |
| August | 160.43 | 69.38 | 91.04 | 185.36 | 53.23 | 0.00 | 0.00 | 0.00 |
| September | 129.86 | 58.69 | 71.16 | 143.91 | 68.10 | 0.00 | 0.00 | 0.00 |
| October | 68.95 | 24.88 | 44.08 | 61.63 | 84.43 | 0.00 | 0.00 | 0.00 |
| November | 37.32 | 10.99 | 26.34 | 23.56 | 103.44 | 0.00 | 0.00 | 0.00 |
| December | 20.96 | 4.36 | 16.60 | 7.55 | 131.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 107.59 | 42.81 | 64.78 | 108.46 | 82.82 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20.96 | 4.36 | 16.60 | 7.55 | 48.50 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 191.15 | 84.33 | 110.24 | 219.10 | 131.00 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.29 | 185.83 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 7.05 | 172.41 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 23.71 | 138.72 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 69.85 | 113.58 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 86.25 | 93.59 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 118.67 | 75.73 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 120.75 | 69.28 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 92.84 | 78.03 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 60.17 | 105.20 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 23.35 | 130.66 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 3.91 | 160.45 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.10 | 201.38 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 50.97 | 126.84 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.10 | 69.28 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 120.75 | 201.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 169.39 | 167.28 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 212.21 | 162.39 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 105.11 | 134.52 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 296.87 | 122.32 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 225.49 | 107.54 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 219.99 | 83.34 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 257.21 | 76.73 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 316.53 | 83.54 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 378.27 | 106.79 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 221.90 | 132.81 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 148.89 | 152.78 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 113.09 | 189.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 221.73 | 126.46 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 105.11 | 76.73 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 378.27 | 189.65 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 40.20 | 16.07 | 24.13 | 22.60 | 117.29 | 0.00 | 0.00 | 0.00 |
| February | 60.32 | 22.37 | 37.95 | 38.41 | 109.89 | 0.00 | 0.00 | 0.00 |
| March | 62.82 | 12.34 | 50.48 | 39.03 | 87.59 | 0.00 | 0.00 | 0.00 |
| April | 168.23 | 78.85 | 89.38 | 174.16 | 75.05 | 0.00 | 0.00 | 0.00 |
| May | 177.25 | 77.21 | 100.04 | 178.80 | 64.64 | 0.00 | 0.00 | 0.00 |
| June | 175.68 | 70.25 | 105.43 | 188.60 | 50.80 | 0.00 | 0.00 | 0.00 |
| July | 179.35 | 76.29 | 103.06 | 201.47 | 46.59 | 0.00 | 0.00 | 0.00 |
| August | 169.97 | 81.24 | 88.73 | 195.42 | 50.89 | 0.00 | 0.00 | 0.00 |
| September | 152.48 | 80.89 | 71.59 | 168.45 | 66.88 | 0.00 | 0.00 | 0.00 |
| October | 74.55 | 31.32 | 43.23 | 64.59 | 87.22 | 0.00 | 0.00 | 0.00 |
| November | 38.34 | 12.99 | 25.35 | 21.74 | 103.17 | 0.00 | 0.00 | 0.00 |
| December | 28.45 | 10.55 | 17.90 | 13.90 | 127.75 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 110.80 | 47.59 | 63.20 | 109.19 | 82.18 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28.45 | 10.55 | 17.90 | 13.90 | 46.59 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 179.35 | 81.24 | 105.43 | 201.47 | 127.75 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 40.20 | 16.07 | 24.13 | 23.52 | 114.19 | 0.00 | 0.00 | 0.00 |
| February | 60.32 | 22.37 | 37.95 | 39.78 | 106.55 | 0.00 | 0.00 | 0.00 |
| March | 62.82 | 12.34 | 50.48 | 39.97 | 86.37 | 0.00 | 0.00 | 0.00 |
| April | 168.23 | 78.85 | 89.38 | 178.44 | 70.83 | 0.00 | 0.00 | 0.00 |
| May | 177.25 | 77.21 | 100.04 | 181.25 | 62.74 | 0.00 | 0.00 | 0.00 |
| June | 175.68 | 70.25 | 105.43 | 189.52 | 50.37 | 0.00 | 0.00 | 0.00 |
| July | 179.35 | 76.29 | 103.06 | 202.49 | 46.17 | 0.00 | 0.00 | 0.00 |
| August | 169.97 | 81.24 | 88.73 | 197.01 | 50.05 | 0.00 | 0.00 | 0.00 |
| September | 152.48 | 80.89 | 71.59 | 171.02 | 64.78 | 0.00 | 0.00 | 0.00 |
| October | 74.55 | 31.32 | 43.23 | 67.59 | 82.17 | 0.00 | 0.00 | 0.00 |
| November | 38.34 | 12.99 | 25.35 | 22.70 | 100.35 | 0.00 | 0.00 | 0.00 |
| December | 28.45 | 10.55 | 17.90 | 14.22 | 126.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 110.80 | 47.59 | 63.20 | 110.88 | 79.92 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28.45 | 10.55 | 17.90 | 14.22 | 46.17 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 179.35 | 81.24 | 105.43 | 202.49 | 126.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.25 | 185.82 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 6.93 | 172.02 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 23.56 | 138.53 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 67.87 | 113.90 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 84.66 | 93.42 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 118.23 | 75.15 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 120.26 | 68.83 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 92.14 | 77.74 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 58.74 | 105.53 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 22.74 | 130.62 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 3.86 | 160.39 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.09 | 201.60 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 50.33 | 126.74 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.09 | 68.83 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 120.26 | 201.60 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.11 | 189.16 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 6.69 | 174.93 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 23.06 | 141.09 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 69.36 | 115.20 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 85.30 | 95.55 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 119.13 | 76.20 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 121.54 | 69.46 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 93.47 | 78.29 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 59.68 | 107.03 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 22.22 | 135.14 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 3.65 | 163.69 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.07 | 205.49 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 50.75 | 129.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.07 | 69.46 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 121.54 | 205.49 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.11 | 189.16 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 6.68 | 174.91 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 23.05 | 141.08 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 69.17 | 115.35 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 85.15 | 95.63 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 119.12 | 76.17 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 121.53 | 69.45 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 93.45 | 78.28 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 59.58 | 107.10 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 22.17 | 135.18 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 3.64 | 163.68 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.07 | 205.50 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 50.70 | 129.07 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.07 | 69.45 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 121.53 | 205.50 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 168.13 | 171.85 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 211.02 | 166.59 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 104.11 | 137.65 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 297.21 | 124.93 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 225.70 | 110.20 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 220.86 | 84.42 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 258.35 | 77.35 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 317.64 | 83.96 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 378.88 | 108.14 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 220.62 | 138.91 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 147.72 | 158.40 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 112.44 | 193.55 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 221.55 | 129.48 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 104.11 | 77.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 378.88 | 193.55 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 168.12 | 171.86 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 211.02 | 166.55 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 104.09 | 137.64 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 297.11 | 125.02 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 225.62 | 110.23 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 220.85 | 84.39 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 258.34 | 77.34 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 317.62 | 83.95 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 378.85 | 108.15 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 220.60 | 138.94 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 147.71 | 158.39 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 112.43 | 193.57 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 221.52 | 129.48 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 104.09 | 77.34 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 378.85 | 193.57 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 170.34 | 159.83 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 212.52 | 156.06 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 106.20 | 128.51 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 299.80 | 111.88 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 229.98 | 96.56 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 222.51 | 75.41 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 258.02 | 70.43 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 317.33 | 76.44 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 381.14 | 95.59 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 224.58 | 120.38 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 149.56 | 145.33 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 113.69 | 182.18 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 223.46 | 118.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 106.20 | 70.43 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 381.14 | 182.18 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.42 | 12.88 | 26.54 | 23.04 | 113.57 | 0.00 | 0.00 | 0.00 |
| February | 69.74 | 29.62 | 40.12 | 53.84 | 107.50 | 0.00 | 0.00 | 0.00 |
| March | 62.85 | 12.08 | 50.77 | 39.59 | 84.86 | 0.00 | 0.00 | 0.00 |
| April | 147.89 | 58.59 | 89.30 | 150.40 | 71.67 | 0.00 | 0.00 | 0.00 |
| May | 173.46 | 70.33 | 103.14 | 177.09 | 59.94 | 0.00 | 0.00 | 0.00 |
| June | 187.69 | 77.44 | 110.24 | 205.81 | 47.40 | 0.00 | 0.00 | 0.00 |
| July | 191.15 | 84.33 | 106.82 | 218.03 | 44.30 | 0.00 | 0.00 | 0.00 |
| August | 160.43 | 69.38 | 91.04 | 183.60 | 49.06 | 0.00 | 0.00 | 0.00 |
| September | 129.86 | 58.69 | 71.16 | 141.84 | 62.50 | 0.00 | 0.00 | 0.00 |
| October | 68.95 | 24.88 | 44.08 | 59.35 | 80.65 | 0.00 | 0.00 | 0.00 |
| November | 37.32 | 10.99 | 26.34 | 22.24 | 100.48 | 0.00 | 0.00 | 0.00 |
| December | 20.96 | 4.36 | 16.60 | 7.09 | 127.31 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 107.59 | 42.81 | 64.78 | 107.01 | 78.96 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20.96 | 4.36 | 16.60 | 7.09 | 44.30 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 191.15 | 84.33 | 110.24 | 218.03 | 127.31 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.42 | 12.88 | 26.54 | 24.74 | 111.49 | 0.00 | 0.00 | 0.00 |
| February | 69.74 | 29.62 | 40.12 | 56.53 | 105.22 | 0.00 | 0.00 | 0.00 |
| March | 62.85 | 12.08 | 50.77 | 40.90 | 84.04 | 0.00 | 0.00 | 0.00 |
| April | 147.89 | 58.59 | 89.30 | 154.95 | 69.58 | 0.00 | 0.00 | 0.00 |
| May | 173.46 | 70.33 | 103.14 | 180.00 | 58.98 | 0.00 | 0.00 | 0.00 |
| June | 187.69 | 77.44 | 110.24 | 207.32 | 47.02 | 0.00 | 0.00 | 0.00 |
| July | 191.15 | 84.33 | 106.82 | 219.77 | 43.85 | 0.00 | 0.00 | 0.00 |
| August | 160.43 | 69.38 | 91.04 | 186.41 | 47.90 | 0.00 | 0.00 | 0.00 |
| September | 129.86 | 58.69 | 71.16 | 146.84 | 59.68 | 0.00 | 0.00 | 0.00 |
| October | 68.95 | 24.88 | 44.08 | 63.01 | 78.09 | 0.00 | 0.00 | 0.00 |
| November | 37.32 | 10.99 | 26.34 | 23.98 | 98.67 | 0.00 | 0.00 | 0.00 |
| December | 20.96 | 4.36 | 16.60 | 7.74 | 125.92 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 107.59 | 42.81 | 64.78 | 109.52 | 77.41 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20.96 | 4.36 | 16.60 | 7.74 | 43.85 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 191.15 | 84.33 | 110.24 | 219.77 | 125.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.56 | 178.21 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 7.61 | 165.63 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 24.59 | 132.59 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 70.96 | 106.62 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 90.56 | 84.74 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 122.38 | 68.18 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 122.93 | 63.40 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 95.19 | 70.69 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 64.69 | 92.64 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 25.38 | 121.06 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.36 | 153.12 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.16 | 193.51 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 52.84 | 118.97 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.16 | 63.40 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 122.93 | 193.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 169.96 | 159.58 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 212.32 | 155.29 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 105.85 | 128.21 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 297.19 | 111.29 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 227.70 | 95.51 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 220.97 | 74.27 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 256.50 | 69.44 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 315.69 | 75.74 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 379.10 | 95.04 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 223.64 | 119.99 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 149.27 | 145.05 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 113.41 | 182.23 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 222.29 | 117.45 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 105.85 | 69.44 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 379.10 | 182.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 40.20 | 16.07 | 24.13 | 23.06 | 112.23 | 0.00 | 0.00 | 0.00 |
| February | 60.32 | 22.37 | 37.95 | 38.87 | 105.50 | 0.00 | 0.00 | 0.00 |
| March | 62.82 | 12.34 | 50.48 | 39.70 | 83.48 | 0.00 | 0.00 | 0.00 |
| April | 168.23 | 78.85 | 89.38 | 175.26 | 68.68 | 0.00 | 0.00 | 0.00 |
| May | 177.25 | 77.21 | 100.04 | 181.30 | 57.83 | 0.00 | 0.00 | 0.00 |
| June | 175.68 | 70.25 | 105.43 | 190.10 | 45.73 | 0.00 | 0.00 | 0.00 |
| July | 179.35 | 76.29 | 103.06 | 201.78 | 42.65 | 0.00 | 0.00 | 0.00 |
| August | 169.97 | 81.24 | 88.73 | 195.72 | 46.67 | 0.00 | 0.00 | 0.00 |
| September | 152.48 | 80.89 | 71.59 | 169.85 | 60.06 | 0.00 | 0.00 | 0.00 |
| October | 74.55 | 31.32 | 43.23 | 65.98 | 78.99 | 0.00 | 0.00 | 0.00 |
| November | 38.34 | 12.99 | 25.35 | 22.14 | 98.10 | 0.00 | 0.00 | 0.00 |
| December | 28.45 | 10.55 | 17.90 | 14.20 | 122.77 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 110.80 | 47.59 | 63.20 | 110.09 | 76.75 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28.45 | 10.55 | 17.90 | 14.20 | 42.65 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 179.35 | 81.24 | 105.43 | 201.78 | 122.77 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 40.20 | 16.07 | 24.13 | 24.12 | 109.45 | 0.00 | 0.00 | 0.00 |
| February | 60.32 | 22.37 | 37.95 | 40.50 | 102.26 | 0.00 | 0.00 | 0.00 |
| March | 62.82 | 12.34 | 50.48 | 40.82 | 82.51 | 0.00 | 0.00 | 0.00 |
| April | 168.23 | 78.85 | 89.38 | 179.37 | 66.24 | 0.00 | 0.00 | 0.00 |
| May | 177.25 | 77.21 | 100.04 | 183.83 | 56.66 | 0.00 | 0.00 | 0.00 |
| June | 175.68 | 70.25 | 105.43 | 191.40 | 45.34 | 0.00 | 0.00 | 0.00 |
| July | 179.35 | 76.29 | 103.06 | 203.27 | 42.19 | 0.00 | 0.00 | 0.00 |
| August | 169.97 | 81.24 | 88.73 | 198.18 | 45.53 | 0.00 | 0.00 | 0.00 |
| September | 152.48 | 80.89 | 71.59 | 174.16 | 57.23 | 0.00 | 0.00 | 0.00 |
| October | 74.55 | 31.32 | 43.23 | 69.27 | 75.94 | 0.00 | 0.00 | 0.00 |
| November | 38.34 | 12.99 | 25.35 | 23.31 | 95.72 | 0.00 | 0.00 | 0.00 |
| December | 28.45 | 10.55 | 17.90 | 14.65 | 121.11 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 110.80 | 47.59 | 63.20 | 112.16 | 74.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 28.45 | 10.55 | 17.90 | 14.65 | 42.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 179.35 | 81.24 | 105.43 | 203.27 | 121.11 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.48 | 178.15 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 7.39 | 165.05 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 24.29 | 132.35 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 68.00 | 105.91 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 88.13 | 83.87 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 120.63 | 67.22 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 121.05 | 62.54 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 92.91 | 69.96 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 61.60 | 92.22 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 24.50 | 120.51 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.26 | 153.01 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.14 | 193.72 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 51.51 | 118.48 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.14 | 62.54 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 121.05 | 193.72 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.42 | 181.27 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 7.32 | 167.93 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 24.14 | 134.79 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 71.42 | 107.35 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 91.19 | 85.70 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 122.66 | 69.73 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 123.40 | 64.62 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 95.42 | 72.21 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 64.83 | 94.22 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 25.25 | 122.84 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.17 | 155.97 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.12 | 197.28 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 52.92 | 120.93 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.12 | 64.62 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 123.40 | 197.28 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 29.98 | 0.00 | 29.98 | 2.41 | 181.27 | 0.00 | 0.00 | 0.00 |
| February | 46.81 | 0.00 | 46.81 | 7.31 | 167.90 | 0.00 | 0.00 | 0.00 |
| March | 64.78 | 0.00 | 64.78 | 24.12 | 134.78 | 0.00 | 0.00 | 0.00 |
| April | 105.62 | 0.57 | 105.05 | 71.13 | 107.35 | 0.00 | 0.00 | 0.00 |
| May | 132.43 | 6.85 | 125.58 | 90.94 | 85.66 | 0.00 | 0.00 | 0.00 |
| June | 145.37 | 8.89 | 136.48 | 122.50 | 69.65 | 0.00 | 0.00 | 0.00 |
| July | 138.20 | 7.82 | 130.39 | 123.23 | 64.58 | 0.00 | 0.00 | 0.00 |
| August | 109.18 | 2.12 | 107.07 | 95.24 | 72.16 | 0.00 | 0.00 | 0.00 |
| September | 82.78 | 0.05 | 82.73 | 64.54 | 94.26 | 0.00 | 0.00 | 0.00 |
| October | 53.01 | 0.00 | 53.01 | 25.17 | 122.82 | 0.00 | 0.00 | 0.00 |
| November | 31.85 | 0.00 | 31.85 | 4.16 | 155.96 | 0.00 | 0.00 | 0.00 |
| December | 21.69 | 0.00 | 21.69 | 0.12 | 197.29 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 80.29 | 2.21 | 78.08 | 52.80 | 120.91 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21.69 | 0.00 | 21.69 | 0.12 | 64.58 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 145.37 | 8.89 | 136.48 | 123.23 | 197.29 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 169.27 | 163.01 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 211.71 | 158.87 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 105.42 | 130.90 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 299.37 | 113.73 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 229.81 | 98.06 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 222.59 | 77.08 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 258.39 | 71.80 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 317.43 | 78.21 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 380.59 | 98.27 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 223.77 | 123.43 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 148.69 | 148.57 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 112.94 | 185.87 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 222.99 | 120.46 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 105.42 | 71.80 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 380.59 | 185.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 170.57 | 110.30 | 60.27 | 169.24 | 163.00 | 0.00 | 0.00 | 0.00 |
| February | 208.06 | 127.03 | 81.03 | 211.68 | 158.80 | 0.00 | 0.00 | 0.00 |
| March | 127.38 | 36.29 | 91.09 | 105.39 | 130.89 | 0.00 | 0.00 | 0.00 |
| April | 263.74 | 117.46 | 146.27 | 299.16 | 113.73 | 0.00 | 0.00 | 0.00 |
| May | 218.16 | 69.30 | 148.86 | 229.63 | 97.99 | 0.00 | 0.00 | 0.00 |
| June | 204.13 | 50.02 | 154.11 | 222.48 | 76.98 | 0.00 | 0.00 | 0.00 |
| July | 220.70 | 69.39 | 151.32 | 258.28 | 71.74 | 0.00 | 0.00 | 0.00 |
| August | 256.61 | 114.59 | 142.02 | 317.34 | 78.15 | 0.00 | 0.00 | 0.00 |
| September | 309.50 | 183.14 | 126.36 | 380.47 | 98.24 | 0.00 | 0.00 | 0.00 |
| October | 202.81 | 115.69 | 87.12 | 223.70 | 123.41 | 0.00 | 0.00 | 0.00 |
| November | 148.54 | 90.33 | 58.21 | 148.66 | 148.54 | 0.00 | 0.00 | 0.00 |
| December | 117.68 | 75.38 | 42.30 | 112.93 | 185.88 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 203.66 | 96.18 | 107.48 | 222.91 | 120.42 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 117.68 | 36.29 | 42.30 | 105.39 | 71.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 309.50 | 183.14 | 154.11 | 380.47 | 185.88 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 9.64 | 3.86 | 5.79 | 5.54 | 27.84 | 704.83 | 0.00 | 0.00 |
| February | 14.47 | 5.37 | 9.11 | 9.32 | 26.28 | 630.17 | 0.00 | 0.00 |
| March | 15.07 | 2.96 | 12.11 | 9.31 | 21.15 | 653.50 | 0.00 | 0.00 |
| April | 40.37 | 18.92 | 21.45 | 42.19 | 17.72 | 393.67 | 0.00 | 0.00 |
| May | 42.53 | 18.53 | 24.00 | 43.17 | 15.33 | 356.00 | 0.00 | 0.00 |
| June | 42.16 | 16.86 | 25.30 | 44.88 | 12.55 | 343.83 | 0.00 | 0.00 |
| July | 43.04 | 18.31 | 24.73 | 47.64 | 11.72 | 349.83 | 0.00 | 0.00 |
| August | 40.79 | 19.49 | 21.29 | 46.48 | 12.64 | 367.50 | 0.00 | 0.00 |
| September | 36.59 | 19.41 | 17.18 | 40.85 | 15.81 | 384.17 | 0.00 | 0.00 |
| October | 17.89 | 7.52 | 10.37 | 16.00 | 20.23 | 553.00 | 0.00 | 0.00 |
| November | 9.20 | 3.12 | 6.08 | 5.31 | 24.69 | 550.83 | 0.00 | 0.00 |
| December | 6.83 | 2.53 | 4.29 | 3.38 | 30.43 | 564.33 | 0.00 | 0.00 |
| Annual Sum or Average | 26.59 | 11.42 | 15.17 | 26.23 | 19.67 | 5851.67 | 0.00 | 0.00 |
| Minimum of Months | 6.83 | 2.53 | 4.29 | 3.38 | 11.72 | 343.83 | 0.00 | 0.00 |
| Maximum of Months | 43.04 | 19.49 | 25.30 | 47.64 | 30.43 | 704.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 28.73 | 11.48 | 17.24 | 18.16 | 73.82 | 0.00 | 0.00 | 0.00 |
| February | 43.11 | 15.99 | 27.12 | 30.60 | 69.48 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 8.82 | 36.08 | 31.16 | 56.11 | 0.00 | 0.00 | 0.00 |
| April | 120.22 | 56.35 | 63.87 | 132.04 | 47.31 | 0.00 | 0.00 | 0.00 |
| May | 126.67 | 55.18 | 71.49 | 134.26 | 41.79 | 0.00 | 0.00 | 0.00 |
| June | 125.55 | 50.20 | 75.35 | 138.04 | 35.09 | 0.00 | 0.00 | 0.00 |
| July | 128.17 | 54.52 | 73.65 | 144.76 | 34.00 | 0.00 | 0.00 | 0.00 |
| August | 121.47 | 58.06 | 63.41 | 140.02 | 37.49 | 0.00 | 0.00 | 0.00 |
| September | 108.97 | 57.81 | 51.16 | 122.62 | 47.05 | 0.83 | 0.00 | 0.00 |
| October | 53.28 | 22.38 | 30.90 | 48.88 | 57.69 | 0.00 | 0.00 | 0.00 |
| November | 27.40 | 9.28 | 18.12 | 17.10 | 67.24 | 0.00 | 0.00 | 0.00 |
| December | 20.33 | 7.54 | 12.79 | 11.05 | 81.61 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 79.18 | 34.01 | 45.17 | 80.90 | 53.98 | 0.83 | 0.00 | 0.00 |
| Minimum of Months | 20.33 | 7.54 | 12.79 | 11.05 | 34.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 128.17 | 58.06 | 75.35 | 144.76 | 81.61 | 0.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 9.64 | 3.86 | 5.79 | 5.17 | 30.34 | 722.17 | 0.00 | 0.00 |
| February | 14.47 | 5.37 | 9.11 | 8.80 | 28.50 | 640.83 | 0.00 | 0.00 |
| March | 15.07 | 2.96 | 12.11 | 8.64 | 22.96 | 703.50 | 0.00 | 0.00 |
| April | 40.37 | 18.92 | 21.45 | 41.07 | 19.25 | 531.33 | 0.00 | 0.00 |
| May | 42.53 | 18.53 | 24.00 | 41.63 | 17.12 | 515.67 | 0.00 | 0.00 |
| June | 42.16 | 16.86 | 25.30 | 43.69 | 13.71 | 465.83 | 0.00 | 0.00 |
| July | 43.04 | 18.31 | 24.73 | 46.78 | 12.61 | 445.67 | 0.00 | 0.00 |
| August | 40.79 | 19.49 | 21.29 | 45.58 | 13.64 | 453.50 | 0.00 | 0.00 |
| September | 36.59 | 19.41 | 17.18 | 39.47 | 17.61 | 491.50 | 0.00 | 0.00 |
| October | 17.89 | 7.52 | 10.37 | 15.05 | 22.86 | 667.83 | 0.00 | 0.00 |
| November | 9.20 | 3.12 | 6.08 | 4.93 | 27.11 | 680.50 | 0.00 | 0.00 |
| December | 6.83 | 2.53 | 4.29 | 3.14 | 33.10 | 731.17 | 0.00 | 0.00 |
| Annual Sum or Average | 26.59 | 11.42 | 15.17 | 25.39 | 21.53 | 7049.50 | 0.00 | 0.00 |
| Minimum of Months | 6.83 | 2.53 | 4.29 | 3.14 | 12.61 | 445.67 | 0.00 | 0.00 |
| Maximum of Months | 43.04 | 19.49 | 25.30 | 46.78 | 33.10 | 731.17 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.463507E+09 | 0.428258E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.524504E+09 | 0.373559E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.294093E+09 | 0.339541E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.801698E+09 | 0.280248E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.635941E+09 | 0.254110E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.591292E+09 | 0.197721E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.703039E+09 | 0.195179E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.857900E+09 | 0.216856E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.991318E+09 | 0.267575E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.605875E+09 | 0.335314E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.392931E+09 | 0.380226E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.308154E+09 | 0.489152E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.717025E+10 | 0.375774E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.294093E+09 | 0.195179E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.991318E+09 | 0.489152E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.105594E+09 | 34499043.26 | 71094546.04 | 65571703.66 | 0.303723E+09 |
| February | 0.168713E+09 | 71663277.87 | 97049742.69 | 0.136642E+09 | 0.257502E+09 |
| March | 0.168343E+09 | 32359127.31 | 0.135984E+09 | 0.112830E+09 | 0.224488E+09 |
| April | 0.383341E+09 | 0.151877E+09 | 0.231464E+09 | 0.408278E+09 | 0.180971E+09 |
| May | 0.464608E+09 | 0.188360E+09 | 0.276248E+09 | 0.490736E+09 | 0.159563E+09 |
| June | 0.486481E+09 | 0.200728E+09 | 0.285752E+09 | 0.545694E+09 | 0.125254E+09 |
| July | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.593949E+09 | 0.123710E+09 |
| August | 0.429690E+09 | 0.185838E+09 | 0.243853E+09 | 0.498480E+09 | 0.139855E+09 |
| September | 0.336591E+09 | 0.152135E+09 | 0.184457E+09 | 0.371072E+09 | 0.176363E+09 |
| October | 0.184688E+09 | 66630123.19 | 0.118058E+09 | 0.162584E+09 | 0.225317E+09 |
| November | 96745549.56 | 28481825.66 | 68263723.90 | 60820195.40 | 0.262807E+09 |
| December | 56147233.41 | 11687166.48 | 44460066.93 | 20325675.62 | 0.341258E+09 |
| Annual Sum or Average | 0.339292E+10 | 0.135013E+10 | 0.204280E+10 | 0.346698E+10 | 0.252081E+10 |
| Minimum of Months | 56147233.41 | 11687166.48 | 44460066.93 | 20325675.62 | 0.123710E+09 |
| Maximum of Months | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.593949E+09 | 0.341258E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.105594E+09 | 34499043.26 | 71094546.04 | 67774196.70 | 0.298415E+09 |
| February | 0.168713E+09 | 71663277.87 | 97049742.69 | 0.139569E+09 | 0.252884E+09 |
| March | 0.168343E+09 | 32359127.31 | 0.135984E+09 | 0.114546E+09 | 0.222759E+09 |
| April | 0.383341E+09 | 0.151877E+09 | 0.231464E+09 | 0.418598E+09 | 0.173214E+09 |
| May | 0.464608E+09 | 0.188360E+09 | 0.276248E+09 | 0.500238E+09 | 0.153117E+09 |
| June | 0.486481E+09 | 0.200728E+09 | 0.285752E+09 | 0.552442E+09 | 0.120631E+09 |
| July | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.599042E+09 | 0.120531E+09 |
| August | 0.429690E+09 | 0.185838E+09 | 0.243853E+09 | 0.505764E+09 | 0.133848E+09 |
| September | 0.336591E+09 | 0.152135E+09 | 0.184457E+09 | 0.383881E+09 | 0.161469E+09 |
| October | 0.184688E+09 | 66630123.19 | 0.118058E+09 | 0.171494E+09 | 0.211892E+09 |
| November | 96745549.56 | 28481825.66 | 68263723.90 | 63088378.13 | 0.257499E+09 |
| December | 56147233.41 | 11687166.48 | 44460066.93 | 21142589.78 | 0.337641E+09 |
| Annual Sum or Average | 0.339292E+10 | 0.135013E+10 | 0.204280E+10 | 0.353758E+10 | 0.244390E+10 |
| Minimum of Months | 56147233.41 | 11687166.48 | 44460066.93 | 21142589.78 | 0.120531E+09 |
| Maximum of Months | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.599042E+09 | 0.337641E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 7806538.56 | 0.475783E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 20894826.62 | 0.396902E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 71552810.06 | 0.350272E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.206108E+09 | 0.263017E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.267790E+09 | 0.219099E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.337717E+09 | 0.174266E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.341929E+09 | 0.173029E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.261845E+09 | 0.196403E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.170497E+09 | 0.249479E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 70515509.31 | 0.327684E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 11981574.03 | 0.399532E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 504880.98 | 0.519345E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.176914E+10 | 0.374481E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 504880.98 | 0.173029E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.341929E+09 | 0.519345E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.475928E+09 | 0.383077E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.537474E+09 | 0.334943E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.306424E+09 | 0.306439E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.797093E+09 | 0.281476E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.628830E+09 | 0.261417E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.582972E+09 | 0.208111E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.689873E+09 | 0.211175E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.846386E+09 | 0.237310E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.983036E+09 | 0.285176E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.604265E+09 | 0.339817E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.398566E+09 | 0.356508E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.317495E+09 | 0.432366E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.716834E+10 | 0.363782E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.306424E+09 | 0.208111E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.983036E+09 | 0.432366E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.107658E+09 | 43038899.42 | 64619585.88 | 69399750.81 | 0.265809E+09 |
| February | 0.145931E+09 | 54124494.36 | 91806425.55 | 0.105225E+09 | 0.224629E+09 |
| March | 0.168261E+09 | 33045218.26 | 0.135216E+09 | 0.120689E+09 | 0.199194E+09 |
| April | 0.436044E+09 | 0.204373E+09 | 0.231672E+09 | 0.471723E+09 | 0.173176E+09 |
| May | 0.474737E+09 | 0.206793E+09 | 0.267943E+09 | 0.497864E+09 | 0.158061E+09 |
| June | 0.455362E+09 | 0.182084E+09 | 0.273278E+09 | 0.498378E+09 | 0.127473E+09 |
| July | 0.480369E+09 | 0.204343E+09 | 0.276025E+09 | 0.540427E+09 | 0.128509E+09 |
| August | 0.455251E+09 | 0.217584E+09 | 0.237667E+09 | 0.522028E+09 | 0.144601E+09 |
| September | 0.395227E+09 | 0.209667E+09 | 0.185560E+09 | 0.438227E+09 | 0.178964E+09 |
| October | 0.199679E+09 | 83884359.61 | 0.115794E+09 | 0.178989E+09 | 0.222997E+09 |
| November | 99387111.29 | 33676090.54 | 65711020.75 | 62072816.71 | 0.239442E+09 |
| December | 76200871.68 | 28268796.97 | 47932074.71 | 42914351.92 | 0.289429E+09 |
| Annual Sum or Average | 0.349411E+10 | 0.150088E+10 | 0.199323E+10 | 0.354794E+10 | 0.235228E+10 |
| Minimum of Months | 76200871.68 | 28268796.97 | 47932074.71 | 42914351.92 | 0.127473E+09 |
| Maximum of Months | 0.480369E+09 | 0.217584E+09 | 0.276025E+09 | 0.540427E+09 | 0.289429E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.107658E+09 | 43038899.42 | 64619585.88 | 65668512.00 | 0.292592E+09 |
| February | 0.145931E+09 | 54124494.36 | 91806425.55 | 0.100258E+09 | 0.245592E+09 |
| March | 0.168261E+09 | 33045218.26 | 0.135216E+09 | 0.113571E+09 | 0.218534E+09 |
| April | 0.436044E+09 | 0.204373E+09 | 0.231672E+09 | 0.482834E+09 | 0.164344E+09 |
| May | 0.474737E+09 | 0.206793E+09 | 0.267943E+09 | 0.510660E+09 | 0.146208E+09 |
| June | 0.455362E+09 | 0.182084E+09 | 0.273278E+09 | 0.510640E+09 | 0.115369E+09 |
| July | 0.480369E+09 | 0.204343E+09 | 0.276025E+09 | 0.553623E+09 | 0.115405E+09 |
| August | 0.455251E+09 | 0.217584E+09 | 0.237667E+09 | 0.536185E+09 | 0.126863E+09 |
| September | 0.395227E+09 | 0.209667E+09 | 0.185560E+09 | 0.454645E+09 | 0.154978E+09 |
| October | 0.199679E+09 | 83884359.61 | 0.115794E+09 | 0.187895E+09 | 0.206190E+09 |
| November | 99387111.29 | 33676090.54 | 65711020.75 | 61015459.77 | 0.249988E+09 |
| December | 76200871.68 | 28268796.97 | 47932074.71 | 39493554.99 | 0.325093E+09 |
| Annual Sum or Average | 0.349411E+10 | 0.150088E+10 | 0.199323E+10 | 0.361649E+10 | 0.236116E+10 |
| Minimum of Months | 76200871.68 | 28268796.97 | 47932074.71 | 39493554.99 | 0.115369E+09 |
| Maximum of Months | 0.480369E+09 | 0.217584E+09 | 0.276025E+09 | 0.553623E+09 | 0.325093E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 7703183.02 | 0.475790E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 20687869.83 | 0.396182E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 71234745.30 | 0.350006E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.203320E+09 | 0.262889E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.265829E+09 | 0.218038E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.336927E+09 | 0.172148E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.339440E+09 | 0.172132E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.258596E+09 | 0.196464E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.166024E+09 | 0.251463E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 69433812.46 | 0.327474E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 11856585.40 | 0.399440E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 481044.47 | 0.519874E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.175153E+10 | 0.374190E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 481044.47 | 0.172132E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.339440E+09 | 0.519874E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 7204692.79 | 0.485350E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 19677235.73 | 0.404166E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 69243359.03 | 0.357692E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.205132E+09 | 0.265983E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.267069E+09 | 0.221293E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.336693E+09 | 0.176825E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.340375E+09 | 0.175749E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.260435E+09 | 0.199866E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.167547E+09 | 0.256431E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 68353822.02 | 0.335561E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 11220218.20 | 0.407681E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 383560.52 | 0.530135E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.175333E+10 | 0.381673E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 383560.52 | 0.175749E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.340375E+09 | 0.530135E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 7200972.97 | 0.485351E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 19669951.18 | 0.404132E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 69232972.70 | 0.357680E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.204935E+09 | 0.266054E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.266938E+09 | 0.221273E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.336760E+09 | 0.176641E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.340111E+09 | 0.175827E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.260205E+09 | 0.199990E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.167073E+09 | 0.256965E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 68286828.53 | 0.335596E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 11215381.75 | 0.407675E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 382779.20 | 0.530166E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.175201E+10 | 0.381735E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 382779.20 | 0.175827E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.340111E+09 | 0.530166E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.460154E+09 | 0.438077E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.521493E+09 | 0.381644E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.290751E+09 | 0.347172E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.797625E+09 | 0.286533E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.632033E+09 | 0.260254E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.588768E+09 | 0.202109E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.701497E+09 | 0.198679E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.857011E+09 | 0.219908E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.988663E+09 | 0.273848E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.601159E+09 | 0.348074E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.390233E+09 | 0.389439E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.306172E+09 | 0.499727E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.713556E+10 | 0.384546E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.290751E+09 | 0.198679E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.988663E+09 | 0.499727E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.460943E+09 | 0.435756E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.522306E+09 | 0.379614E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.291383E+09 | 0.345584E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.797024E+09 | 0.286899E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.630896E+09 | 0.261260E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.587646E+09 | 0.203026E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.700382E+09 | 0.199692E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.856153E+09 | 0.220852E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.987971E+09 | 0.274763E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.600817E+09 | 0.348666E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.390564E+09 | 0.388133E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.306673E+09 | 0.497184E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.713276E+10 | 0.384143E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.291383E+09 | 0.199692E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.987971E+09 | 0.497184E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.454318E+09 | 0.448398E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.513609E+09 | 0.394210E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.282185E+09 | 0.360749E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.773551E+09 | 0.316347E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.607223E+09 | 0.288675E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.571310E+09 | 0.217593E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.690089E+09 | 0.206685E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.849228E+09 | 0.224543E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.982504E+09 | 0.277043E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.595730E+09 | 0.355898E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.386398E+09 | 0.396450E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.303381E+09 | 0.507602E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.700953E+10 | 0.399419E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.282185E+09 | 0.206685E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.982504E+09 | 0.507602E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.105594E+09 | 34499043.26 | 71094546.04 | 61880936.19 | 0.319122E+09 |
| February | 0.168713E+09 | 71663277.87 | 97049742.69 | 0.131013E+09 | 0.272363E+09 |
| March | 0.168343E+09 | 32359127.31 | 0.135984E+09 | 0.105113E+09 | 0.238780E+09 |
| April | 0.383341E+09 | 0.151877E+09 | 0.231464E+09 | 0.388552E+09 | 0.203960E+09 |
| May | 0.464608E+09 | 0.188360E+09 | 0.276248E+09 | 0.468642E+09 | 0.180205E+09 |
| June | 0.486481E+09 | 0.200728E+09 | 0.285752E+09 | 0.530633E+09 | 0.137805E+09 |
| July | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.584055E+09 | 0.130960E+09 |
| August | 0.429690E+09 | 0.185838E+09 | 0.243853E+09 | 0.492051E+09 | 0.144913E+09 |
| September | 0.336591E+09 | 0.152135E+09 | 0.184457E+09 | 0.365570E+09 | 0.182852E+09 |
| October | 0.184688E+09 | 66630123.19 | 0.118058E+09 | 0.156579E+09 | 0.239510E+09 |
| November | 96745549.56 | 28481825.66 | 68263723.90 | 57864869.02 | 0.274692E+09 |
| December | 56147233.41 | 11687166.48 | 44460066.93 | 19133866.27 | 0.355139E+09 |
| Annual Sum or Average | 0.339292E+10 | 0.135013E+10 | 0.204280E+10 | 0.336109E+10 | 0.268030E+10 |
| Minimum of Months | 56147233.41 | 11687166.48 | 44460066.93 | 19133866.27 | 0.130960E+09 |
| Maximum of Months | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.584055E+09 | 0.355139E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.105594E+09 | 34499043.26 | 71094546.04 | 65238994.52 | 0.311822E+09 |
| February | 0.168713E+09 | 71663277.87 | 97049742.69 | 0.135663E+09 | 0.265368E+09 |
| March | 0.168343E+09 | 32359127.31 | 0.135984E+09 | 0.107813E+09 | 0.235866E+09 |
| April | 0.383341E+09 | 0.151877E+09 | 0.231464E+09 | 0.400231E+09 | 0.192845E+09 |
| May | 0.464608E+09 | 0.188360E+09 | 0.276248E+09 | 0.475818E+09 | 0.174943E+09 |
| June | 0.486481E+09 | 0.200728E+09 | 0.285752E+09 | 0.533026E+09 | 0.136749E+09 |
| July | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.586836E+09 | 0.129907E+09 |
| August | 0.429690E+09 | 0.185838E+09 | 0.243853E+09 | 0.496470E+09 | 0.142570E+09 |
| September | 0.336591E+09 | 0.152135E+09 | 0.184457E+09 | 0.373027E+09 | 0.176504E+09 |
| October | 0.184688E+09 | 66630123.19 | 0.118058E+09 | 0.165066E+09 | 0.226136E+09 |
| November | 96745549.56 | 28481825.66 | 68263723.90 | 61068876.63 | 0.268129E+09 |
| December | 56147233.41 | 11687166.48 | 44460066.93 | 20229706.71 | 0.350882E+09 |
| Annual Sum or Average | 0.339292E+10 | 0.135013E+10 | 0.204280E+10 | 0.342049E+10 | 0.261172E+10 |
| Minimum of Months | 56147233.41 | 11687166.48 | 44460066.93 | 20229706.71 | 0.129907E+09 |
| Maximum of Months | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.586836E+09 | 0.350882E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 6137324.65 | 0.497728E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 17052273.82 | 0.417090E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 63514312.28 | 0.371540E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.181056E+09 | 0.294396E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.231006E+09 | 0.250671E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.307597E+09 | 0.196301E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.323406E+09 | 0.185547E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.248658E+09 | 0.209006E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.155951E+09 | 0.272667E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 62553636.91 | 0.349950E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 10140586.72 | 0.415896E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 273314.66 | 0.539373E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.160735E+10 | 0.400017E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 273314.66 | 0.185547E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.323406E+09 | 0.539373E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.453697E+09 | 0.448041E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.513371E+09 | 0.392862E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.281516E+09 | 0.360305E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.769485E+09 | 0.317046E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.603956E+09 | 0.288032E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.570224E+09 | 0.216023E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.688919E+09 | 0.205518E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.847793E+09 | 0.223761E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.980475E+09 | 0.276801E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.594328E+09 | 0.355707E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.385926E+09 | 0.396012E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.302893E+09 | 0.507954E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.699258E+10 | 0.398806E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.281516E+09 | 0.205518E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.980475E+09 | 0.507954E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.107658E+09 | 43038899.42 | 64619585.88 | 60541945.48 | 0.314151E+09 |
| February | 0.145931E+09 | 54124494.36 | 91806425.55 | 92910365.92 | 0.265848E+09 |
| March | 0.168261E+09 | 33045218.26 | 0.135216E+09 | 0.104530E+09 | 0.234588E+09 |
| April | 0.436044E+09 | 0.204373E+09 | 0.231672E+09 | 0.451423E+09 | 0.194536E+09 |
| May | 0.474737E+09 | 0.206793E+09 | 0.267943E+09 | 0.478911E+09 | 0.173122E+09 |
| June | 0.455362E+09 | 0.182084E+09 | 0.273278E+09 | 0.488862E+09 | 0.131670E+09 |
| July | 0.480369E+09 | 0.204343E+09 | 0.276025E+09 | 0.539616E+09 | 0.124777E+09 |
| August | 0.455251E+09 | 0.217584E+09 | 0.237667E+09 | 0.523401E+09 | 0.136313E+09 |
| September | 0.395227E+09 | 0.209667E+09 | 0.185560E+09 | 0.436616E+09 | 0.173344E+09 |
| October | 0.199679E+09 | 83884359.61 | 0.115794E+09 | 0.172989E+09 | 0.233612E+09 |
| November | 99387111.29 | 33676090.54 | 65711020.75 | 56360197.04 | 0.267413E+09 |
| December | 76200871.68 | 28268796.97 | 47932074.71 | 37218786.84 | 0.342160E+09 |
| Annual Sum or Average | 0.349411E+10 | 0.150088E+10 | 0.199323E+10 | 0.344338E+10 | 0.259154E+10 |
| Minimum of Months | 76200871.68 | 28268796.97 | 47932074.71 | 37218786.84 | 0.124777E+09 |
| Maximum of Months | 0.480369E+09 | 0.217584E+09 | 0.276025E+09 | 0.539616E+09 | 0.342160E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.107658E+09 | 43038899.42 | 64619585.88 | 63002189.62 | 0.305839E+09 |
| February | 0.145931E+09 | 54124494.36 | 91806425.55 | 96236551.59 | 0.257762E+09 |
| March | 0.168261E+09 | 33045218.26 | 0.135216E+09 | 0.107062E+09 | 0.231321E+09 |
| April | 0.436044E+09 | 0.204373E+09 | 0.231672E+09 | 0.462521E+09 | 0.183600E+09 |
| May | 0.474737E+09 | 0.206793E+09 | 0.267943E+09 | 0.485459E+09 | 0.168031E+09 |
| June | 0.455362E+09 | 0.182084E+09 | 0.273278E+09 | 0.491225E+09 | 0.130567E+09 |
| July | 0.480369E+09 | 0.204343E+09 | 0.276025E+09 | 0.542342E+09 | 0.123654E+09 |
| August | 0.455251E+09 | 0.217584E+09 | 0.237667E+09 | 0.527676E+09 | 0.134053E+09 |
| September | 0.395227E+09 | 0.209667E+09 | 0.185560E+09 | 0.443291E+09 | 0.167903E+09 |
| October | 0.199679E+09 | 83884359.61 | 0.115794E+09 | 0.181041E+09 | 0.220094E+09 |
| November | 99387111.29 | 33676090.54 | 65711020.75 | 58827085.32 | 0.260109E+09 |
| December | 76200871.68 | 28268796.97 | 47932074.71 | 38093856.29 | 0.337562E+09 |
| Annual Sum or Average | 0.349411E+10 | 0.150088E+10 | 0.199323E+10 | 0.349678E+10 | 0.252049E+10 |
| Minimum of Months | 76200871.68 | 28268796.97 | 47932074.71 | 38093856.29 | 0.123654E+09 |
| Maximum of Months | 0.480369E+09 | 0.217584E+09 | 0.276025E+09 | 0.542342E+09 | 0.337562E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 6016535.80 | 0.497707E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 16769643.95 | 0.416155E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 63106148.16 | 0.371026E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.175917E+09 | 0.295222E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.226742E+09 | 0.250213E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.306453E+09 | 0.194782E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.322091E+09 | 0.184363E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.246797E+09 | 0.208214E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.152252E+09 | 0.273528E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 60900908.46 | 0.349843E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 9994799.05 | 0.415731E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 252991.96 | 0.539974E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.158729E+10 | 0.399676E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 252991.96 | 0.184363E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.322091E+09 | 0.539974E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 5648447.67 | 0.506658E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 16177245.05 | 0.423191E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 61750674.26 | 0.377906E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.179770E+09 | 0.298603E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.228474E+09 | 0.255920E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.308795E+09 | 0.197514E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.325545E+09 | 0.186047E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.250357E+09 | 0.209696E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.154678E+09 | 0.277418E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 59505595.96 | 0.361946E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 9453931.08 | 0.424279E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 194226.89 | 0.550379E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.160035E+10 | 0.406956E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 194226.89 | 0.186047E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.325545E+09 | 0.550379E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 5642886.43 | 0.506659E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 16165771.62 | 0.423144E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 61733439.22 | 0.377879E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.179288E+09 | 0.298987E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.228058E+09 | 0.256126E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.308768E+09 | 0.197440E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.325493E+09 | 0.186010E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.250285E+09 | 0.209673E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.154423E+09 | 0.277606E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 59376529.32 | 0.362067E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 9447046.26 | 0.424264E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 193563.19 | 0.550423E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.159887E+10 | 0.407028E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 193563.19 | 0.186010E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.325493E+09 | 0.550423E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.450321E+09 | 0.460293E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.510509E+09 | 0.403026E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.278835E+09 | 0.368680E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.770374E+09 | 0.323808E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.604507E+09 | 0.295155E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.572460E+09 | 0.218810E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.691976E+09 | 0.207168E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.850754E+09 | 0.224878E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.982049E+09 | 0.280296E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.590921E+09 | 0.372067E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.382884E+09 | 0.410564E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.301148E+09 | 0.518403E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.698674E+10 | 0.408315E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.278835E+09 | 0.207168E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.982049E+09 | 0.518403E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.450284E+09 | 0.460297E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.510501E+09 | 0.402911E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.278801E+09 | 0.368660E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.770097E+09 | 0.324043E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.604306E+09 | 0.295228E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.572431E+09 | 0.218730E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.691927E+09 | 0.207134E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.850705E+09 | 0.224852E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.981973E+09 | 0.280316E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.590848E+09 | 0.372127E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.382861E+09 | 0.410542E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.301125E+09 | 0.518450E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.698586E+10 | 0.408329E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.278801E+09 | 0.207134E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.981973E+09 | 0.518450E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.456232E+09 | 0.428101E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.514135E+09 | 0.377544E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.284441E+09 | 0.344188E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.777074E+09 | 0.289986E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.615966E+09 | 0.258629E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.576739E+09 | 0.195472E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.691094E+09 | 0.188645E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.849931E+09 | 0.204750E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.987912E+09 | 0.247780E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.601502E+09 | 0.322434E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.387654E+09 | 0.376707E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.304509E+09 | 0.487945E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.704719E+10 | 0.372218E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.284441E+09 | 0.188645E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.987912E+09 | 0.487945E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.105594E+09 | 34499043.26 | 71094546.04 | 61715557.92 | 0.304191E+09 |
| February | 0.168713E+09 | 71663277.87 | 97049742.69 | 0.130254E+09 | 0.260058E+09 |
| March | 0.168343E+09 | 32359127.31 | 0.135984E+09 | 0.106049E+09 | 0.227278E+09 |
| April | 0.383341E+09 | 0.151877E+09 | 0.231464E+09 | 0.389845E+09 | 0.185766E+09 |
| May | 0.464608E+09 | 0.188360E+09 | 0.276248E+09 | 0.474313E+09 | 0.160547E+09 |
| June | 0.486481E+09 | 0.200728E+09 | 0.285752E+09 | 0.533471E+09 | 0.122870E+09 |
| July | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.583964E+09 | 0.118651E+09 |
| August | 0.429690E+09 | 0.185838E+09 | 0.243853E+09 | 0.491767E+09 | 0.131415E+09 |
| September | 0.336591E+09 | 0.152135E+09 | 0.184457E+09 | 0.367646E+09 | 0.162000E+09 |
| October | 0.184688E+09 | 66630123.19 | 0.118058E+09 | 0.158975E+09 | 0.216003E+09 |
| November | 96745549.56 | 28481825.66 | 68263723.90 | 57656205.26 | 0.260449E+09 |
| December | 56147233.41 | 11687166.48 | 44460066.93 | 18978085.82 | 0.340993E+09 |
| Annual Sum or Average | 0.339292E+10 | 0.135013E+10 | 0.204280E+10 | 0.337463E+10 | 0.249022E+10 |
| Minimum of Months | 56147233.41 | 11687166.48 | 44460066.93 | 18978085.82 | 0.118651E+09 |
| Maximum of Months | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.583964E+09 | 0.340993E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.105594E+09 | 34499043.26 | 71094546.04 | 66258519.84 | 0.298612E+09 |
| February | 0.168713E+09 | 71663277.87 | 97049742.69 | 0.136755E+09 | 0.254542E+09 |
| March | 0.168343E+09 | 32359127.31 | 0.135984E+09 | 0.109554E+09 | 0.225101E+09 |
| April | 0.383341E+09 | 0.151877E+09 | 0.231464E+09 | 0.401631E+09 | 0.180353E+09 |
| May | 0.464608E+09 | 0.188360E+09 | 0.276248E+09 | 0.482117E+09 | 0.157966E+09 |
| June | 0.486481E+09 | 0.200728E+09 | 0.285752E+09 | 0.537377E+09 | 0.121884E+09 |
| July | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.588627E+09 | 0.117440E+09 |
| August | 0.429690E+09 | 0.185838E+09 | 0.243853E+09 | 0.499277E+09 | 0.128292E+09 |
| September | 0.336591E+09 | 0.152135E+09 | 0.184457E+09 | 0.380621E+09 | 0.154702E+09 |
| October | 0.184688E+09 | 66630123.19 | 0.118058E+09 | 0.168758E+09 | 0.209147E+09 |
| November | 96745549.56 | 28481825.66 | 68263723.90 | 62154659.61 | 0.255754E+09 |
| December | 56147233.41 | 11687166.48 | 44460066.93 | 20722923.15 | 0.337265E+09 |
| Annual Sum or Average | 0.339292E+10 | 0.135013E+10 | 0.204280E+10 | 0.345385E+10 | 0.244106E+10 |
| Minimum of Months | 56147233.41 | 11687166.48 | 44460066.93 | 20722923.15 | 0.117440E+09 |
| Maximum of Months | 0.511983E+09 | 0.225869E+09 | 0.286114E+09 | 0.588627E+09 | 0.337265E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 6857776.31 | 0.477307E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 18400594.57 | 0.400682E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 65859378.47 | 0.355118E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.183928E+09 | 0.276364E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.242567E+09 | 0.226972E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.317221E+09 | 0.176733E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.329252E+09 | 0.169809E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.254952E+09 | 0.189346E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.167668E+09 | 0.240119E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 67964775.03 | 0.324236E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 11299919.34 | 0.396886E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 420609.98 | 0.518293E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.166639E+10 | 0.375187E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 420609.98 | 0.169809E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.329252E+09 | 0.518293E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.455228E+09 | 0.427423E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.513640E+09 | 0.375683E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.283498E+09 | 0.343387E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.770310E+09 | 0.288469E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.609866E+09 | 0.255808E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.572754E+09 | 0.192502E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.686996E+09 | 0.186000E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.845545E+09 | 0.202855E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.982628E+09 | 0.246355E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.598994E+09 | 0.321391E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.386912E+09 | 0.375977E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.303758E+09 | 0.488074E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.701013E+10 | 0.370392E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.283498E+09 | 0.186000E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.982628E+09 | 0.488074E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.107658E+09 | 43038899.42 | 64619585.88 | 61769348.53 | 0.300591E+09 |
| February | 0.145931E+09 | 54124494.36 | 91806425.55 | 94037897.73 | 0.255237E+09 |
| March | 0.168261E+09 | 33045218.26 | 0.135216E+09 | 0.106337E+09 | 0.223586E+09 |
| April | 0.436044E+09 | 0.204373E+09 | 0.231672E+09 | 0.454261E+09 | 0.178025E+09 |
| May | 0.474737E+09 | 0.206793E+09 | 0.267943E+09 | 0.485598E+09 | 0.154880E+09 |
| June | 0.455362E+09 | 0.182084E+09 | 0.273278E+09 | 0.492749E+09 | 0.118542E+09 |
| July | 0.480369E+09 | 0.204343E+09 | 0.276025E+09 | 0.540440E+09 | 0.114237E+09 |
| August | 0.455251E+09 | 0.217584E+09 | 0.237667E+09 | 0.524218E+09 | 0.125009E+09 |
| September | 0.395227E+09 | 0.209667E+09 | 0.185560E+09 | 0.440241E+09 | 0.155674E+09 |
| October | 0.199679E+09 | 83884359.61 | 0.115794E+09 | 0.176721E+09 | 0.211574E+09 |
| November | 99387111.29 | 33676090.54 | 65711020.75 | 57379111.80 | 0.254274E+09 |
| December | 76200871.68 | 28268796.97 | 47932074.71 | 38032169.99 | 0.328838E+09 |
| Annual Sum or Average | 0.349411E+10 | 0.150088E+10 | 0.199323E+10 | 0.347178E+10 | 0.242047E+10 |
| Minimum of Months | 76200871.68 | 28268796.97 | 47932074.71 | 38032169.99 | 0.114237E+09 |
| Maximum of Months | 0.480369E+09 | 0.217584E+09 | 0.276025E+09 | 0.540440E+09 | 0.328838E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.107658E+09 | 43038899.42 | 64619585.88 | 64608884.42 | 0.293147E+09 |
| February | 0.145931E+09 | 54124494.36 | 91806425.55 | 97975297.52 | 0.247382E+09 |
| March | 0.168261E+09 | 33045218.26 | 0.135216E+09 | 0.109334E+09 | 0.220997E+09 |
| April | 0.436044E+09 | 0.204373E+09 | 0.231672E+09 | 0.464927E+09 | 0.171705E+09 |
| May | 0.474737E+09 | 0.206793E+09 | 0.267943E+09 | 0.492361E+09 | 0.151750E+09 |
| June | 0.455362E+09 | 0.182084E+09 | 0.273278E+09 | 0.496121E+09 | 0.117533E+09 |
| July | 0.480369E+09 | 0.204343E+09 | 0.276025E+09 | 0.544446E+09 | 0.113014E+09 |
| August | 0.455251E+09 | 0.217584E+09 | 0.237667E+09 | 0.530811E+09 | 0.121945E+09 |
| September | 0.395227E+09 | 0.209667E+09 | 0.185560E+09 | 0.451427E+09 | 0.148347E+09 |
| October | 0.199679E+09 | 83884359.61 | 0.115794E+09 | 0.185543E+09 | 0.203396E+09 |
| November | 99387111.29 | 33676090.54 | 65711020.75 | 60414681.02 | 0.248117E+09 |
| December | 76200871.68 | 28268796.97 | 47932074.71 | 39230503.43 | 0.324393E+09 |
| Annual Sum or Average | 0.349411E+10 | 0.150088E+10 | 0.199323E+10 | 0.353720E+10 | 0.236172E+10 |
| Minimum of Months | 76200871.68 | 28268796.97 | 47932074.71 | 39230503.43 | 0.113014E+09 |
| Maximum of Months | 0.480369E+09 | 0.217584E+09 | 0.276025E+09 | 0.544446E+09 | 0.324393E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 6637416.01 | 0.477153E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 17879715.20 | 0.399299E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 65050096.69 | 0.354494E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.176248E+09 | 0.274530E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.236036E+09 | 0.224642E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.312660E+09 | 0.174239E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.324220E+09 | 0.167520E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.248853E+09 | 0.187370E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.159660E+09 | 0.239044E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 65622872.24 | 0.322784E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 11037853.19 | 0.396599E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 382154.32 | 0.518852E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.162429E+10 | 0.373652E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 382154.32 | 0.167520E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.324220E+09 | 0.518852E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 6481168.41 | 0.485522E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 17715773.25 | 0.406264E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 64664980.34 | 0.361026E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.185122E+09 | 0.278244E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.244251E+09 | 0.229545E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.317926E+09 | 0.180733E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.330513E+09 | 0.173076E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.255561E+09 | 0.193394E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.168035E+09 | 0.244210E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 67621909.24 | 0.329023E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 10803429.79 | 0.404276E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 330053.44 | 0.528382E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.166903E+10 | 0.381370E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 330053.44 | 0.173076E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.330513E+09 | 0.528382E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 80287531.65 | 0.00 | 80287531.65 | 6467621.69 | 0.485510E+09 |
| February | 0.113240E+09 | 0.00 | 0.113240E+09 | 17681377.08 | 0.406183E+09 |
| March | 0.173511E+09 | 2459.32 | 0.173509E+09 | 64609324.74 | 0.360998E+09 |
| April | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.184375E+09 | 0.278260E+09 |
| May | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.243564E+09 | 0.229441E+09 |
| June | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.317518E+09 | 0.180546E+09 |
| July | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.330050E+09 | 0.172958E+09 |
| August | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.255104E+09 | 0.193282E+09 |
| September | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.167286E+09 | 0.244323E+09 |
| October | 0.141972E+09 | 0.00 | 0.141972E+09 | 67411460.55 | 0.328949E+09 |
| November | 82552649.24 | 0.00 | 82552649.24 | 10785341.97 | 0.404252E+09 |
| December | 58092086.33 | 0.00 | 58092086.33 | 328137.47 | 0.528411E+09 |
| Annual Sum or Average | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.166518E+10 | 0.381311E+10 |
| Minimum of Months | 58092086.33 | 0.00 | 58092086.33 | 328137.47 | 0.172958E+09 |
| Maximum of Months | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.330050E+09 | 0.528411E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.453377E+09 | 0.436613E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.512176E+09 | 0.384339E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.282349E+09 | 0.350610E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.775961E+09 | 0.294798E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.615518E+09 | 0.262632E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.576945E+09 | 0.199794E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.692084E+09 | 0.192315E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.850209E+09 | 0.209475E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.986481E+09 | 0.254712E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.599332E+09 | 0.330587E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.385392E+09 | 0.385082E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.302510E+09 | 0.497841E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.703233E+10 | 0.379880E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.282349E+09 | 0.192315E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.986481E+09 | 0.497841E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.453289E+09 | 0.436580E+09 |
| February | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.512107E+09 | 0.384178E+09 |
| March | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.282268E+09 | 0.350562E+09 |
| April | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.775431E+09 | 0.294777E+09 |
| May | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.615032E+09 | 0.262457E+09 |
| June | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.576674E+09 | 0.199542E+09 |
| July | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.691790E+09 | 0.192138E+09 |
| August | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.849951E+09 | 0.209328E+09 |
| September | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.986167E+09 | 0.254641E+09 |
| October | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.599162E+09 | 0.330534E+09 |
| November | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.385328E+09 | 0.385026E+09 |
| December | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.302463E+09 | 0.497869E+09 |
| Annual Sum or Average | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.702966E+10 | 0.379763E+10 |
| Minimum of Months | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.282268E+09 | 0.192138E+09 |
| Maximum of Months | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.986167E+09 | 0.497869E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 25833091.76 | 10327359.10 | 15505732.66 | 14835809.45 | 74558128.87 |
| February | 35016718.23 | 12987392.73 | 22029325.50 | 22558962.12 | 63565399.88 |
| March | 40375009.83 | 7929334.63 | 32445675.21 | 24937151.26 | 56642344.78 |
| April | 0.104631E+09 | 49040048.07 | 55590536.04 | 0.109361E+09 | 45934740.05 |
| May | 0.113915E+09 | 49620905.25 | 64294087.41 | 0.115624E+09 | 41061812.49 |
| June | 0.109266E+09 | 43691914.28 | 65574135.68 | 0.116331E+09 | 32538026.76 |
| July | 0.115266E+09 | 49032981.58 | 66233399.09 | 0.127611E+09 | 31401330.75 |
| August | 0.109239E+09 | 52210172.79 | 57029254.48 | 0.124486E+09 | 33847368.25 |
| September | 94836422.31 | 50310452.31 | 44525970.00 | 0.105873E+09 | 40987412.33 |
| October | 47913730.77 | 20128393.53 | 27785337.24 | 42845375.78 | 54194238.10 |
| November | 23848341.90 | 8080715.00 | 15767626.90 | 13762627.10 | 63988156.19 |
| December | 18284709.33 | 6783212.90 | 11501496.43 | 9065490.57 | 81511624.90 |
| Annual Sum or Average | 0.838425E+09 | 0.360143E+09 | 0.478283E+09 | 0.827290E+09 | 0.620231E+09 |
| Minimum of Months | 18284709.33 | 6783212.90 | 11501496.43 | 9065490.57 | 31401330.75 |
| Maximum of Months | 0.115266E+09 | 52210172.79 | 66233399.09 | 0.127611E+09 | 81511624.90 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 76937376.17 | 30757445.51 | 46179930.67 | 48631448.58 | 0.197715E+09 |
| February | 0.104289E+09 | 38679687.63 | 65608813.63 | 74026874.19 | 0.168075E+09 |
| March | 0.120247E+09 | 23615531.84 | 96631295.30 | 83468006.91 | 0.150285E+09 |
| April | 0.311616E+09 | 0.146053E+09 | 0.165562E+09 | 0.342259E+09 | 0.122637E+09 |
| May | 0.339267E+09 | 0.147783E+09 | 0.191484E+09 | 0.359597E+09 | 0.111928E+09 |
| June | 0.325421E+09 | 0.130125E+09 | 0.195296E+09 | 0.357808E+09 | 90951295.98 |
| July | 0.343292E+09 | 0.146032E+09 | 0.197260E+09 | 0.387716E+09 | 91067160.92 |
| August | 0.325342E+09 | 0.155495E+09 | 0.169847E+09 | 0.375026E+09 | 0.100403E+09 |
| September | 0.282446E+09 | 0.149837E+09 | 0.132609E+09 | 0.317819E+09 | 0.121962E+09 |
| October | 0.142699E+09 | 59947365.16 | 82751649.05 | 0.130917E+09 | 0.154509E+09 |
| November | 71026297.15 | 24066380.26 | 46959916.89 | 44315248.11 | 0.174282E+09 |
| December | 54456414.77 | 20202096.11 | 34254318.66 | 29604650.16 | 0.218583E+09 |
| Annual Sum or Average | 0.249704E+10 | 0.107260E+10 | 0.142444E+10 | 0.255119E+10 | 0.170240E+10 |
| Minimum of Months | 54456414.77 | 20202096.11 | 34254318.66 | 29604650.16 | 90951295.98 |
| Maximum of Months | 0.343292E+09 | 0.155495E+09 | 0.197260E+09 | 0.387716E+09 | 0.218583E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 25833091.76 | 10327359.10 | 15505732.66 | 13842334.48 | 81257249.49 |
| February | 35016718.23 | 12987392.73 | 22029325.50 | 21282539.59 | 68935743.44 |
| March | 40375009.83 | 7929334.63 | 32445675.21 | 23129712.41 | 61482740.85 |
| April | 0.104631E+09 | 49040048.07 | 55590536.04 | 0.106455E+09 | 49908284.10 |
| May | 0.113915E+09 | 49620905.25 | 64294087.41 | 0.111489E+09 | 45859975.49 |
| June | 0.109266E+09 | 43691914.28 | 65574135.68 | 0.113244E+09 | 35534002.29 |
| July | 0.115266E+09 | 49032981.58 | 66233399.09 | 0.125283E+09 | 33765560.10 |
| August | 0.109239E+09 | 52210172.79 | 57029254.48 | 0.122069E+09 | 36534454.51 |
| September | 94836422.31 | 50310452.31 | 44525970.00 | 0.102294E+09 | 45633567.72 |
| October | 47913730.77 | 20128393.53 | 27785337.24 | 40312451.46 | 61223000.40 |
| November | 23848341.90 | 8080715.00 | 15767626.90 | 12773871.40 | 70259549.77 |
| December | 18284709.33 | 6783212.90 | 11501496.43 | 8423519.32 | 88667497.02 |
| Annual Sum or Average | 0.838425E+09 | 0.360143E+09 | 0.478283E+09 | 0.800599E+09 | 0.679062E+09 |
| Minimum of Months | 18284709.33 | 6783212.90 | 11501496.43 | 8423519.32 | 33765560.10 |
| Maximum of Months | 0.115266E+09 | 52210172.79 | 66233399.09 | 0.125283E+09 | 88667497.02 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 191.37 | 267.13 | 210.00 | 123.18 | 86.81 | 0.00 | 0.00 |
| February | 269.81 | 257.38 | 277.80 | 156.66 | 121.15 | 0.00 | 0.00 |
| March | 150.26 | 208.91 | 190.23 | 48.38 | 141.86 | 0.00 | 0.00 |
| April | 464.62 | 175.74 | 411.63 | 176.06 | 235.57 | 0.00 | 0.00 |
| May | 417.34 | 151.13 | 391.63 | 139.63 | 252.00 | 0.00 | 0.00 |
| June | 436.98 | 122.93 | 391.82 | 127.46 | 264.35 | 0.00 | 0.00 |
| July | 482.25 | 117.07 | 411.86 | 153.72 | 258.14 | 0.00 | 0.00 |
| August | 505.10 | 131.87 | 417.04 | 183.97 | 233.07 | 0.00 | 0.00 |
| September | 523.70 | 169.36 | 439.36 | 241.83 | 197.53 | 0.00 | 0.00 |
| October | 284.87 | 207.27 | 271.76 | 140.57 | 131.19 | 0.00 | 0.00 |
| November | 171.45 | 244.47 | 185.86 | 101.32 | 84.54 | 0.00 | 0.00 |
| December | 117.04 | 304.44 | 138.65 | 79.75 | 58.90 | 0.00 | 0.00 |
| Annual Sum or Average | 334.39 | 196.18 | 311.24 | 138.99 | 172.25 | 0.00 | 0.00 |
| Minimum of Months | 117.04 | 117.07 | 138.65 | 48.38 | 58.90 | 0.00 | 0.00 |
| Maximum of Months | 523.70 | 304.44 | 439.36 | 241.83 | 264.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 22.55 | 283.39 | 69.40 | 12.88 | 56.52 | 0.00 | 0.00 |
| February | 62.48 | 264.74 | 116.55 | 29.62 | 86.93 | 0.00 | 0.00 |
| March | 67.15 | 211.62 | 127.63 | 12.08 | 115.55 | 0.00 | 0.00 |
| April | 239.57 | 166.86 | 253.51 | 59.17 | 194.34 | 0.00 | 0.00 |
| May | 284.91 | 137.13 | 305.90 | 77.18 | 228.72 | 0.00 | 0.00 |
| June | 341.86 | 112.21 | 333.06 | 86.33 | 246.72 | 0.00 | 0.00 |
| July | 349.76 | 108.05 | 329.36 | 92.14 | 237.21 | 0.00 | 0.00 |
| August | 285.68 | 122.39 | 269.61 | 71.50 | 198.11 | 0.00 | 0.00 |
| September | 212.31 | 156.98 | 212.64 | 58.74 | 153.89 | 0.00 | 0.00 |
| October | 88.70 | 199.80 | 121.96 | 24.88 | 97.08 | 0.00 | 0.00 |
| November | 26.53 | 251.05 | 69.17 | 10.99 | 58.19 | 0.00 | 0.00 |
| December | 6.01 | 317.89 | 42.65 | 4.36 | 38.29 | 0.00 | 0.00 |
| Annual Sum or Average | 166.04 | 194.01 | 187.88 | 45.02 | 142.86 | 0.00 | 0.00 |
| Minimum of Months | 6.01 | 108.05 | 42.65 | 4.36 | 38.29 | 0.00 | 0.00 |
| Maximum of Months | 349.76 | 317.89 | 333.06 | 92.14 | 246.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 199.54 | 238.21 | 210.77 | 126.37 | 84.39 | 0.00 | 0.00 |
| February | 263.27 | 228.91 | 268.38 | 149.41 | 118.98 | 0.00 | 0.00 |
| March | 158.19 | 187.51 | 190.20 | 48.63 | 141.57 | 0.00 | 0.00 |
| April | 484.18 | 170.07 | 431.96 | 196.31 | 235.65 | 0.00 | 0.00 |
| May | 415.37 | 151.32 | 395.41 | 146.51 | 248.90 | 0.00 | 0.00 |
| June | 413.82 | 126.10 | 379.81 | 120.27 | 259.54 | 0.00 | 0.00 |
| July | 455.63 | 123.11 | 400.05 | 145.68 | 254.37 | 0.00 | 0.00 |
| August | 506.49 | 138.18 | 426.58 | 195.82 | 230.76 | 0.00 | 0.00 |
| September | 543.69 | 174.43 | 461.98 | 264.03 | 197.95 | 0.00 | 0.00 |
| October | 290.83 | 208.52 | 277.36 | 147.01 | 130.35 | 0.00 | 0.00 |
| November | 175.92 | 228.13 | 186.88 | 103.32 | 83.56 | 0.00 | 0.00 |
| December | 132.83 | 267.76 | 146.13 | 85.94 | 60.20 | 0.00 | 0.00 |
| Annual Sum or Average | 336.51 | 186.64 | 314.45 | 143.77 | 170.68 | 0.00 | 0.00 |
| Minimum of Months | 132.83 | 123.11 | 146.13 | 48.63 | 60.20 | 0.00 | 0.00 |
| Maximum of Months | 543.69 | 267.76 | 461.98 | 264.03 | 259.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 19.77 | 279.26 | 70.17 | 16.07 | 54.10 | 0.00 | 0.00 |
| February | 43.86 | 259.15 | 107.13 | 22.37 | 84.76 | 0.00 | 0.00 |
| March | 66.36 | 209.63 | 127.60 | 12.34 | 115.26 | 0.00 | 0.00 |
| April | 260.59 | 160.70 | 273.84 | 79.42 | 194.42 | 0.00 | 0.00 |
| May | 288.17 | 134.26 | 309.68 | 84.06 | 225.62 | 0.00 | 0.00 |
| June | 326.06 | 109.99 | 321.05 | 79.14 | 241.91 | 0.00 | 0.00 |
| July | 332.37 | 106.29 | 317.55 | 84.11 | 233.44 | 0.00 | 0.00 |
| August | 295.27 | 119.25 | 279.16 | 83.35 | 195.80 | 0.00 | 0.00 |
| September | 234.08 | 151.43 | 235.26 | 80.94 | 154.32 | 0.00 | 0.00 |
| October | 92.21 | 195.38 | 127.56 | 31.32 | 96.24 | 0.00 | 0.00 |
| November | 23.08 | 245.52 | 70.19 | 12.99 | 57.20 | 0.00 | 0.00 |
| December | 8.31 | 308.86 | 50.14 | 10.55 | 39.58 | 0.00 | 0.00 |
| Annual Sum or Average | 166.35 | 189.66 | 191.09 | 49.80 | 141.29 | 0.00 | 0.00 |
| Minimum of Months | 8.31 | 106.29 | 50.14 | 10.55 | 39.58 | 0.00 | 0.00 |
| Maximum of Months | 332.37 | 308.86 | 321.05 | 84.11 | 241.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 2.69 | 181.21 | 29.98 | 0.00 | 29.98 | 0.00 | 0.00 |
| February | 8.13 | 167.07 | 46.81 | 0.00 | 46.81 | 0.00 | 0.00 |
| March | 25.85 | 133.55 | 64.78 | 0.00 | 64.78 | 0.00 | 0.00 |
| April | 79.14 | 102.62 | 105.62 | 0.57 | 105.05 | 0.00 | 0.00 |
| May | 99.71 | 82.62 | 132.43 | 6.85 | 125.58 | 0.00 | 0.00 |
| June | 129.90 | 68.22 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
| July | 127.08 | 65.62 | 138.20 | 7.82 | 130.39 | 0.00 | 0.00 |
| August | 97.24 | 74.62 | 109.18 | 2.12 | 107.07 | 0.00 | 0.00 |
| September | 64.64 | 98.93 | 82.78 | 0.05 | 82.73 | 0.00 | 0.00 |
| October | 25.52 | 125.28 | 53.01 | 0.00 | 53.01 | 0.00 | 0.00 |
| November | 4.33 | 157.28 | 31.85 | 0.00 | 31.85 | 0.00 | 0.00 |
| December | 0.14 | 197.93 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Annual Sum or Average | 55.60 | 121.03 | 80.29 | 2.21 | 78.08 | 0.00 | 0.00 |
| Minimum of Months | 0.14 | 65.62 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Maximum of Months | 129.90 | 197.93 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 2.69 | 181.21 | 29.98 | 0.00 | 29.98 | 0.00 | 0.00 |
| February | 8.13 | 167.05 | 46.81 | 0.00 | 46.81 | 0.00 | 0.00 |
| March | 25.85 | 133.54 | 64.78 | 0.00 | 64.78 | 0.00 | 0.00 |
| April | 79.06 | 102.64 | 105.62 | 0.57 | 105.05 | 0.00 | 0.00 |
| May | 99.66 | 82.61 | 132.43 | 6.85 | 125.58 | 0.00 | 0.00 |
| June | 129.92 | 68.15 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
| July | 126.98 | 65.65 | 138.20 | 7.82 | 130.39 | 0.00 | 0.00 |
| August | 97.15 | 74.67 | 109.18 | 2.12 | 107.07 | 0.00 | 0.00 |
| September | 64.46 | 99.14 | 82.78 | 0.05 | 82.73 | 0.00 | 0.00 |
| October | 25.50 | 125.30 | 53.01 | 0.00 | 53.01 | 0.00 | 0.00 |
| November | 4.33 | 157.28 | 31.85 | 0.00 | 31.85 | 0.00 | 0.00 |
| December | 0.14 | 197.94 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Annual Sum or Average | 55.56 | 121.05 | 80.29 | 2.21 | 78.08 | 0.00 | 0.00 |
| Minimum of Months | 0.14 | 65.65 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Maximum of Months | 129.92 | 197.94 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 171.80 | 163.56 | 170.57 | 110.30 | 60.27 | 0.00 | 0.00 |
| February | 215.56 | 157.76 | 208.06 | 127.03 | 81.03 | 0.00 | 0.00 |
| March | 108.55 | 129.62 | 127.38 | 36.29 | 91.09 | 0.00 | 0.00 |
| April | 307.73 | 110.55 | 263.74 | 117.46 | 146.27 | 0.00 | 0.00 |
| May | 235.97 | 97.17 | 218.16 | 69.30 | 148.86 | 0.00 | 0.00 |
| June | 227.15 | 77.97 | 204.13 | 50.02 | 154.11 | 0.00 | 0.00 |
| July | 261.91 | 74.18 | 220.70 | 69.39 | 151.32 | 0.00 | 0.00 |
| August | 319.97 | 82.10 | 256.61 | 114.59 | 142.02 | 0.00 | 0.00 |
| September | 381.43 | 105.65 | 309.50 | 183.14 | 126.36 | 0.00 | 0.00 |
| October | 224.45 | 129.96 | 202.81 | 115.69 | 87.12 | 0.00 | 0.00 |
| November | 150.55 | 150.25 | 148.54 | 90.33 | 58.21 | 0.00 | 0.00 |
| December | 114.31 | 186.58 | 117.68 | 75.38 | 42.30 | 0.00 | 0.00 |
| Annual Sum or Average | 226.27 | 121.94 | 203.66 | 96.18 | 107.48 | 0.00 | 0.00 |
| Minimum of Months | 108.55 | 74.18 | 117.68 | 36.29 | 42.30 | 0.00 | 0.00 |
| Maximum of Months | 381.43 | 186.58 | 309.50 | 183.14 | 154.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 172.10 | 162.69 | 170.57 | 110.30 | 60.27 | 0.00 | 0.00 |
| February | 215.90 | 156.92 | 208.06 | 127.03 | 81.03 | 0.00 | 0.00 |
| March | 108.79 | 129.03 | 127.38 | 36.29 | 91.09 | 0.00 | 0.00 |
| April | 307.49 | 110.69 | 263.74 | 117.46 | 146.27 | 0.00 | 0.00 |
| May | 235.55 | 97.54 | 218.16 | 69.30 | 148.86 | 0.00 | 0.00 |
| June | 226.72 | 78.33 | 204.13 | 50.02 | 154.11 | 0.00 | 0.00 |
| July | 261.49 | 74.56 | 220.70 | 69.39 | 151.32 | 0.00 | 0.00 |
| August | 319.65 | 82.46 | 256.61 | 114.59 | 142.02 | 0.00 | 0.00 |
| September | 381.16 | 106.00 | 309.50 | 183.14 | 126.36 | 0.00 | 0.00 |
| October | 224.32 | 130.18 | 202.81 | 115.69 | 87.12 | 0.00 | 0.00 |
| November | 150.68 | 149.74 | 148.54 | 90.33 | 58.21 | 0.00 | 0.00 |
| December | 114.50 | 185.63 | 117.68 | 75.38 | 42.30 | 0.00 | 0.00 |
| Annual Sum or Average | 226.18 | 121.81 | 203.66 | 96.18 | 107.48 | 0.00 | 0.00 |
| Minimum of Months | 108.79 | 74.56 | 117.68 | 36.29 | 42.30 | 0.00 | 0.00 |
| Maximum of Months | 381.16 | 185.63 | 309.50 | 183.14 | 154.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 186.05 | 279.88 | 210.00 | 123.18 | 86.81 | 0.00 | 0.00 |
| February | 262.64 | 271.71 | 277.80 | 156.66 | 121.15 | 0.00 | 0.00 |
| March | 142.74 | 221.97 | 190.23 | 48.38 | 141.86 | 0.00 | 0.00 |
| April | 445.52 | 197.92 | 411.63 | 176.06 | 235.57 | 0.00 | 0.00 |
| May | 397.48 | 170.85 | 391.63 | 139.63 | 252.00 | 0.00 | 0.00 |
| June | 423.11 | 135.09 | 391.82 | 127.46 | 264.35 | 0.00 | 0.00 |
| July | 473.52 | 123.88 | 411.86 | 153.72 | 258.14 | 0.00 | 0.00 |
| August | 499.36 | 136.52 | 417.04 | 183.97 | 233.07 | 0.00 | 0.00 |
| September | 518.02 | 175.36 | 439.36 | 241.83 | 197.53 | 0.00 | 0.00 |
| October | 278.66 | 220.08 | 271.76 | 140.57 | 131.19 | 0.00 | 0.00 |
| November | 167.52 | 255.05 | 185.86 | 101.32 | 84.54 | 0.00 | 0.00 |
| December | 114.37 | 316.07 | 138.65 | 79.75 | 58.90 | 0.00 | 0.00 |
| Annual Sum or Average | 325.58 | 208.38 | 311.24 | 138.99 | 172.25 | 0.00 | 0.00 |
| Minimum of Months | 114.37 | 123.88 | 138.65 | 48.38 | 58.90 | 0.00 | 0.00 |
| Maximum of Months | 518.02 | 316.07 | 439.36 | 241.83 | 264.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.58 | 296.18 | 69.40 | 12.88 | 56.52 | 0.00 | 0.00 |
| February | 58.73 | 277.71 | 116.55 | 29.62 | 86.93 | 0.00 | 0.00 |
| March | 61.34 | 224.16 | 127.63 | 12.08 | 115.55 | 0.00 | 0.00 |
| April | 222.21 | 185.93 | 253.51 | 59.17 | 194.34 | 0.00 | 0.00 |
| May | 261.80 | 156.81 | 305.90 | 77.18 | 228.72 | 0.00 | 0.00 |
| June | 322.44 | 126.61 | 333.06 | 86.33 | 246.72 | 0.00 | 0.00 |
| July | 338.09 | 116.03 | 329.36 | 92.14 | 237.21 | 0.00 | 0.00 |
| August | 277.23 | 130.29 | 269.61 | 71.50 | 198.11 | 0.00 | 0.00 |
| September | 202.22 | 171.43 | 212.64 | 58.74 | 153.89 | 0.00 | 0.00 |
| October | 83.07 | 213.17 | 121.96 | 24.88 | 97.08 | 0.00 | 0.00 |
| November | 24.81 | 261.24 | 69.17 | 10.99 | 58.19 | 0.00 | 0.00 |
| December | 5.37 | 330.10 | 42.65 | 4.36 | 38.29 | 0.00 | 0.00 |
| Annual Sum or Average | 156.90 | 207.13 | 187.88 | 45.02 | 142.86 | 0.00 | 0.00 |
| Minimum of Months | 5.37 | 116.03 | 42.65 | 4.36 | 38.29 | 0.00 | 0.00 |
| Maximum of Months | 338.09 | 330.10 | 333.06 | 92.14 | 246.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 186.34 | 278.92 | 210.77 | 126.37 | 84.39 | 0.00 | 0.00 |
| February | 246.94 | 268.61 | 268.38 | 149.41 | 118.98 | 0.00 | 0.00 |
| March | 142.54 | 220.51 | 190.20 | 48.63 | 141.57 | 0.00 | 0.00 |
| April | 464.65 | 190.99 | 431.96 | 196.31 | 235.65 | 0.00 | 0.00 |
| May | 398.11 | 165.99 | 395.41 | 146.51 | 248.90 | 0.00 | 0.00 |
| June | 404.91 | 130.45 | 379.81 | 120.27 | 259.54 | 0.00 | 0.00 |
| July | 454.97 | 119.61 | 400.05 | 145.68 | 254.37 | 0.00 | 0.00 |
| August | 507.71 | 130.20 | 426.58 | 195.82 | 230.76 | 0.00 | 0.00 |
| September | 542.16 | 169.11 | 461.98 | 264.03 | 197.95 | 0.00 | 0.00 |
| October | 284.75 | 218.29 | 277.36 | 147.01 | 130.35 | 0.00 | 0.00 |
| November | 168.20 | 253.52 | 186.88 | 103.32 | 83.56 | 0.00 | 0.00 |
| December | 124.17 | 314.59 | 146.13 | 85.94 | 60.20 | 0.00 | 0.00 |
| Annual Sum or Average | 327.04 | 204.75 | 314.45 | 143.77 | 170.68 | 0.00 | 0.00 |
| Minimum of Months | 124.17 | 119.61 | 146.13 | 48.63 | 60.20 | 0.00 | 0.00 |
| Maximum of Months | 542.16 | 314.59 | 461.98 | 264.03 | 259.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 17.82 | 292.06 | 70.17 | 16.07 | 54.10 | 0.00 | 0.00 |
| February | 40.14 | 272.00 | 107.13 | 22.37 | 84.76 | 0.00 | 0.00 |
| March | 60.67 | 222.03 | 127.60 | 12.34 | 115.26 | 0.00 | 0.00 |
| April | 241.22 | 179.63 | 273.84 | 79.42 | 194.42 | 0.00 | 0.00 |
| May | 263.72 | 153.97 | 309.68 | 84.06 | 225.62 | 0.00 | 0.00 |
| June | 306.45 | 124.23 | 321.05 | 79.14 | 241.91 | 0.00 | 0.00 |
| July | 321.55 | 113.81 | 317.55 | 84.11 | 233.44 | 0.00 | 0.00 |
| August | 287.42 | 126.06 | 279.16 | 83.35 | 195.80 | 0.00 | 0.00 |
| September | 223.57 | 164.12 | 235.26 | 80.94 | 154.32 | 0.00 | 0.00 |
| October | 86.07 | 208.53 | 127.56 | 31.32 | 96.24 | 0.00 | 0.00 |
| November | 21.25 | 255.44 | 70.19 | 12.99 | 57.20 | 0.00 | 0.00 |
| December | 7.44 | 320.75 | 50.14 | 10.55 | 39.58 | 0.00 | 0.00 |
| Annual Sum or Average | 156.94 | 202.39 | 191.09 | 49.80 | 141.29 | 0.00 | 0.00 |
| Minimum of Months | 7.44 | 113.81 | 50.14 | 10.55 | 39.58 | 0.00 | 0.00 |
| Maximum of Months | 321.55 | 320.75 | 321.05 | 84.11 | 241.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 2.11 | 189.16 | 29.98 | 0.00 | 29.98 | 0.00 | 0.00 |
| February | 6.69 | 174.93 | 46.81 | 0.00 | 46.81 | 0.00 | 0.00 |
| March | 23.06 | 141.09 | 64.78 | 0.00 | 64.78 | 0.00 | 0.00 |
| April | 69.36 | 115.20 | 105.62 | 0.57 | 105.05 | 0.00 | 0.00 |
| May | 85.30 | 95.55 | 132.43 | 6.85 | 125.58 | 0.00 | 0.00 |
| June | 119.13 | 76.20 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
| July | 121.54 | 69.46 | 138.20 | 7.82 | 130.39 | 0.00 | 0.00 |
| August | 93.47 | 78.29 | 109.18 | 2.12 | 107.07 | 0.00 | 0.00 |
| September | 59.68 | 107.03 | 82.78 | 0.05 | 82.73 | 0.00 | 0.00 |
| October | 22.22 | 135.14 | 53.01 | 0.00 | 53.01 | 0.00 | 0.00 |
| November | 3.65 | 163.69 | 31.85 | 0.00 | 31.85 | 0.00 | 0.00 |
| December | 0.07 | 205.49 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Annual Sum or Average | 50.75 | 129.04 | 80.29 | 2.21 | 78.08 | 0.00 | 0.00 |
| Minimum of Months | 0.07 | 69.46 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Maximum of Months | 121.54 | 205.49 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 2.11 | 189.16 | 29.98 | 0.00 | 29.98 | 0.00 | 0.00 |
| February | 6.68 | 174.91 | 46.81 | 0.00 | 46.81 | 0.00 | 0.00 |
| March | 23.05 | 141.08 | 64.78 | 0.00 | 64.78 | 0.00 | 0.00 |
| April | 69.17 | 115.35 | 105.62 | 0.57 | 105.05 | 0.00 | 0.00 |
| May | 85.15 | 95.63 | 132.43 | 6.85 | 125.58 | 0.00 | 0.00 |
| June | 119.12 | 76.17 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
| July | 121.53 | 69.45 | 138.20 | 7.82 | 130.39 | 0.00 | 0.00 |
| August | 93.45 | 78.28 | 109.18 | 2.12 | 107.07 | 0.00 | 0.00 |
| September | 59.58 | 107.10 | 82.78 | 0.05 | 82.73 | 0.00 | 0.00 |
| October | 22.17 | 135.18 | 53.01 | 0.00 | 53.01 | 0.00 | 0.00 |
| November | 3.64 | 163.68 | 31.85 | 0.00 | 31.85 | 0.00 | 0.00 |
| December | 0.07 | 205.50 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Annual Sum or Average | 50.70 | 129.07 | 80.29 | 2.21 | 78.08 | 0.00 | 0.00 |
| Minimum of Months | 0.07 | 69.45 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Maximum of Months | 121.53 | 205.50 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 168.13 | 171.85 | 170.57 | 110.30 | 60.27 | 0.00 | 0.00 |
| February | 211.02 | 166.59 | 208.06 | 127.03 | 81.03 | 0.00 | 0.00 |
| March | 104.11 | 137.65 | 127.38 | 36.29 | 91.09 | 0.00 | 0.00 |
| April | 297.21 | 124.93 | 263.74 | 117.46 | 146.27 | 0.00 | 0.00 |
| May | 225.70 | 110.20 | 218.16 | 69.30 | 148.86 | 0.00 | 0.00 |
| June | 220.86 | 84.42 | 204.13 | 50.02 | 154.11 | 0.00 | 0.00 |
| July | 258.35 | 77.35 | 220.70 | 69.39 | 151.32 | 0.00 | 0.00 |
| August | 317.64 | 83.96 | 256.61 | 114.59 | 142.02 | 0.00 | 0.00 |
| September | 378.88 | 108.14 | 309.50 | 183.14 | 126.36 | 0.00 | 0.00 |
| October | 220.62 | 138.91 | 202.81 | 115.69 | 87.12 | 0.00 | 0.00 |
| November | 147.72 | 158.40 | 148.54 | 90.33 | 58.21 | 0.00 | 0.00 |
| December | 112.44 | 193.55 | 117.68 | 75.38 | 42.30 | 0.00 | 0.00 |
| Annual Sum or Average | 221.55 | 129.48 | 203.66 | 96.18 | 107.48 | 0.00 | 0.00 |
| Minimum of Months | 104.11 | 77.35 | 117.68 | 36.29 | 42.30 | 0.00 | 0.00 |
| Maximum of Months | 378.88 | 193.55 | 309.50 | 183.14 | 154.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 168.12 | 171.86 | 170.57 | 110.30 | 60.27 | 0.00 | 0.00 |
| February | 211.02 | 166.55 | 208.06 | 127.03 | 81.03 | 0.00 | 0.00 |
| March | 104.09 | 137.64 | 127.38 | 36.29 | 91.09 | 0.00 | 0.00 |
| April | 297.11 | 125.02 | 263.74 | 117.46 | 146.27 | 0.00 | 0.00 |
| May | 225.62 | 110.23 | 218.16 | 69.30 | 148.86 | 0.00 | 0.00 |
| June | 220.85 | 84.39 | 204.13 | 50.02 | 154.11 | 0.00 | 0.00 |
| July | 258.34 | 77.34 | 220.70 | 69.39 | 151.32 | 0.00 | 0.00 |
| August | 317.62 | 83.95 | 256.61 | 114.59 | 142.02 | 0.00 | 0.00 |
| September | 378.85 | 108.15 | 309.50 | 183.14 | 126.36 | 0.00 | 0.00 |
| October | 220.60 | 138.94 | 202.81 | 115.69 | 87.12 | 0.00 | 0.00 |
| November | 147.71 | 158.39 | 148.54 | 90.33 | 58.21 | 0.00 | 0.00 |
| December | 112.43 | 193.57 | 117.68 | 75.38 | 42.30 | 0.00 | 0.00 |
| Annual Sum or Average | 221.52 | 129.48 | 203.66 | 96.18 | 107.48 | 0.00 | 0.00 |
| Minimum of Months | 104.09 | 77.34 | 117.68 | 36.29 | 42.30 | 0.00 | 0.00 |
| Maximum of Months | 378.85 | 193.57 | 309.50 | 183.14 | 154.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 186.96 | 266.99 | 210.00 | 123.18 | 86.81 | 0.00 | 0.00 |
| February | 262.76 | 259.95 | 277.80 | 156.66 | 121.15 | 0.00 | 0.00 |
| March | 143.98 | 211.54 | 190.23 | 48.38 | 141.86 | 0.00 | 0.00 |
| April | 447.37 | 180.72 | 411.63 | 176.06 | 235.57 | 0.00 | 0.00 |
| May | 402.88 | 152.32 | 391.63 | 139.63 | 252.00 | 0.00 | 0.00 |
| June | 426.23 | 120.72 | 391.82 | 127.46 | 264.35 | 0.00 | 0.00 |
| July | 473.77 | 112.45 | 411.86 | 153.72 | 258.14 | 0.00 | 0.00 |
| August | 499.44 | 124.02 | 417.04 | 183.97 | 233.07 | 0.00 | 0.00 |
| September | 521.13 | 156.25 | 439.36 | 241.83 | 197.53 | 0.00 | 0.00 |
| October | 282.01 | 199.11 | 271.76 | 140.57 | 131.19 | 0.00 | 0.00 |
| November | 168.16 | 242.18 | 185.86 | 101.32 | 84.54 | 0.00 | 0.00 |
| December | 114.97 | 303.68 | 138.65 | 79.75 | 58.90 | 0.00 | 0.00 |
| Annual Sum or Average | 327.31 | 193.83 | 311.24 | 138.99 | 172.25 | 0.00 | 0.00 |
| Minimum of Months | 114.97 | 112.45 | 138.65 | 48.38 | 58.90 | 0.00 | 0.00 |
| Maximum of Months | 521.13 | 303.68 | 439.36 | 241.83 | 264.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 21.36 | 283.75 | 69.40 | 12.88 | 56.52 | 0.00 | 0.00 |
| February | 59.75 | 266.46 | 116.55 | 29.62 | 86.93 | 0.00 | 0.00 |
| March | 62.88 | 214.02 | 127.63 | 12.08 | 115.55 | 0.00 | 0.00 |
| April | 223.67 | 173.96 | 253.51 | 59.17 | 194.34 | 0.00 | 0.00 |
| May | 268.59 | 141.74 | 305.90 | 77.18 | 228.72 | 0.00 | 0.00 |
| June | 328.18 | 113.68 | 333.06 | 86.33 | 246.72 | 0.00 | 0.00 |
| July | 341.25 | 105.80 | 329.36 | 92.14 | 237.21 | 0.00 | 0.00 |
| August | 280.52 | 117.51 | 269.61 | 71.50 | 198.11 | 0.00 | 0.00 |
| September | 209.67 | 150.46 | 212.64 | 58.74 | 153.89 | 0.00 | 0.00 |
| October | 86.47 | 197.23 | 121.96 | 24.88 | 97.08 | 0.00 | 0.00 |
| November | 25.76 | 249.21 | 69.17 | 10.99 | 58.19 | 0.00 | 0.00 |
| December | 5.71 | 317.25 | 42.65 | 4.36 | 38.29 | 0.00 | 0.00 |
| Annual Sum or Average | 159.89 | 193.91 | 187.88 | 45.02 | 142.86 | 0.00 | 0.00 |
| Minimum of Months | 5.71 | 105.80 | 42.65 | 4.36 | 38.29 | 0.00 | 0.00 |
| Maximum of Months | 341.25 | 317.25 | 333.06 | 92.14 | 246.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 187.25 | 266.03 | 210.77 | 126.37 | 84.39 | 0.00 | 0.00 |
| February | 247.22 | 256.83 | 268.38 | 149.41 | 118.98 | 0.00 | 0.00 |
| March | 143.94 | 210.08 | 190.20 | 48.63 | 141.57 | 0.00 | 0.00 |
| April | 467.08 | 174.61 | 431.96 | 196.31 | 235.65 | 0.00 | 0.00 |
| May | 403.93 | 148.26 | 395.41 | 146.51 | 248.90 | 0.00 | 0.00 |
| June | 408.23 | 117.16 | 379.81 | 120.27 | 259.54 | 0.00 | 0.00 |
| July | 455.45 | 109.27 | 400.05 | 145.68 | 254.37 | 0.00 | 0.00 |
| August | 508.03 | 119.03 | 426.58 | 195.82 | 230.76 | 0.00 | 0.00 |
| September | 545.36 | 151.52 | 461.98 | 264.03 | 197.95 | 0.00 | 0.00 |
| October | 287.99 | 197.36 | 277.36 | 147.01 | 130.35 | 0.00 | 0.00 |
| November | 168.84 | 240.59 | 186.88 | 103.32 | 83.56 | 0.00 | 0.00 |
| December | 124.76 | 302.15 | 146.13 | 85.94 | 60.20 | 0.00 | 0.00 |
| Annual Sum or Average | 328.93 | 190.75 | 314.45 | 143.77 | 170.68 | 0.00 | 0.00 |
| Minimum of Months | 124.76 | 109.27 | 146.13 | 48.63 | 60.20 | 0.00 | 0.00 |
| Maximum of Months | 545.36 | 302.15 | 461.98 | 264.03 | 259.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 18.88 | 279.88 | 70.17 | 16.07 | 54.10 | 0.00 | 0.00 |
| February | 41.64 | 261.07 | 107.13 | 22.37 | 84.76 | 0.00 | 0.00 |
| March | 62.38 | 212.14 | 127.60 | 12.34 | 115.26 | 0.00 | 0.00 |
| April | 243.17 | 167.96 | 273.84 | 79.42 | 194.42 | 0.00 | 0.00 |
| May | 270.01 | 138.59 | 309.68 | 84.06 | 225.62 | 0.00 | 0.00 |
| June | 310.91 | 111.44 | 321.05 | 79.14 | 241.91 | 0.00 | 0.00 |
| July | 323.23 | 103.65 | 317.55 | 84.11 | 233.44 | 0.00 | 0.00 |
| August | 289.96 | 114.36 | 279.16 | 83.35 | 195.80 | 0.00 | 0.00 |
| September | 231.18 | 144.88 | 235.26 | 80.94 | 154.32 | 0.00 | 0.00 |
| October | 90.04 | 192.72 | 127.56 | 31.32 | 96.24 | 0.00 | 0.00 |
| November | 22.55 | 243.71 | 70.19 | 12.99 | 57.20 | 0.00 | 0.00 |
| December | 8.14 | 308.18 | 50.14 | 10.55 | 39.58 | 0.00 | 0.00 |
| Annual Sum or Average | 159.84 | 189.55 | 191.09 | 49.80 | 141.29 | 0.00 | 0.00 |
| Minimum of Months | 8.14 | 103.65 | 50.14 | 10.55 | 39.58 | 0.00 | 0.00 |
| Maximum of Months | 323.23 | 308.18 | 321.05 | 84.11 | 241.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 2.42 | 181.27 | 29.98 | 0.00 | 29.98 | 0.00 | 0.00 |
| February | 7.32 | 167.93 | 46.81 | 0.00 | 46.81 | 0.00 | 0.00 |
| March | 24.14 | 134.79 | 64.78 | 0.00 | 64.78 | 0.00 | 0.00 |
| April | 71.42 | 107.35 | 105.62 | 0.57 | 105.05 | 0.00 | 0.00 |
| May | 91.19 | 85.70 | 132.43 | 6.85 | 125.58 | 0.00 | 0.00 |
| June | 122.66 | 69.73 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
| July | 123.40 | 64.62 | 138.20 | 7.82 | 130.39 | 0.00 | 0.00 |
| August | 95.42 | 72.21 | 109.18 | 2.12 | 107.07 | 0.00 | 0.00 |
| September | 64.83 | 94.22 | 82.78 | 0.05 | 82.73 | 0.00 | 0.00 |
| October | 25.25 | 122.84 | 53.01 | 0.00 | 53.01 | 0.00 | 0.00 |
| November | 4.17 | 155.97 | 31.85 | 0.00 | 31.85 | 0.00 | 0.00 |
| December | 0.12 | 197.28 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Annual Sum or Average | 52.92 | 120.93 | 80.29 | 2.21 | 78.08 | 0.00 | 0.00 |
| Minimum of Months | 0.12 | 64.62 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Maximum of Months | 123.40 | 197.28 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 2.41 | 181.27 | 29.98 | 0.00 | 29.98 | 0.00 | 0.00 |
| February | 7.31 | 167.90 | 46.81 | 0.00 | 46.81 | 0.00 | 0.00 |
| March | 24.12 | 134.78 | 64.78 | 0.00 | 64.78 | 0.00 | 0.00 |
| April | 71.13 | 107.35 | 105.62 | 0.57 | 105.05 | 0.00 | 0.00 |
| May | 90.94 | 85.66 | 132.43 | 6.85 | 125.58 | 0.00 | 0.00 |
| June | 122.50 | 69.65 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
| July | 123.23 | 64.58 | 138.20 | 7.82 | 130.39 | 0.00 | 0.00 |
| August | 95.24 | 72.16 | 109.18 | 2.12 | 107.07 | 0.00 | 0.00 |
| September | 64.54 | 94.26 | 82.78 | 0.05 | 82.73 | 0.00 | 0.00 |
| October | 25.17 | 122.82 | 53.01 | 0.00 | 53.01 | 0.00 | 0.00 |
| November | 4.16 | 155.96 | 31.85 | 0.00 | 31.85 | 0.00 | 0.00 |
| December | 0.12 | 197.29 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Annual Sum or Average | 52.80 | 120.91 | 80.29 | 2.21 | 78.08 | 0.00 | 0.00 |
| Minimum of Months | 0.12 | 64.58 | 21.69 | 0.00 | 21.69 | 0.00 | 0.00 |
| Maximum of Months | 123.23 | 197.29 | 145.37 | 8.89 | 136.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 169.27 | 163.01 | 170.57 | 110.30 | 60.27 | 0.00 | 0.00 |
| February | 211.71 | 158.87 | 208.06 | 127.03 | 81.03 | 0.00 | 0.00 |
| March | 105.42 | 130.90 | 127.38 | 36.29 | 91.09 | 0.00 | 0.00 |
| April | 299.37 | 113.73 | 263.74 | 117.46 | 146.27 | 0.00 | 0.00 |
| May | 229.81 | 98.06 | 218.16 | 69.30 | 148.86 | 0.00 | 0.00 |
| June | 222.59 | 77.08 | 204.13 | 50.02 | 154.11 | 0.00 | 0.00 |
| July | 258.39 | 71.80 | 220.70 | 69.39 | 151.32 | 0.00 | 0.00 |
| August | 317.43 | 78.21 | 256.61 | 114.59 | 142.02 | 0.00 | 0.00 |
| September | 380.59 | 98.27 | 309.50 | 183.14 | 126.36 | 0.00 | 0.00 |
| October | 223.77 | 123.43 | 202.81 | 115.69 | 87.12 | 0.00 | 0.00 |
| November | 148.69 | 148.57 | 148.54 | 90.33 | 58.21 | 0.00 | 0.00 |
| December | 112.94 | 185.87 | 117.68 | 75.38 | 42.30 | 0.00 | 0.00 |
| Annual Sum or Average | 222.99 | 120.46 | 203.66 | 96.18 | 107.48 | 0.00 | 0.00 |
| Minimum of Months | 105.42 | 71.80 | 117.68 | 36.29 | 42.30 | 0.00 | 0.00 |
| Maximum of Months | 380.59 | 185.87 | 309.50 | 183.14 | 154.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 169.24 | 163.00 | 170.57 | 110.30 | 60.27 | 0.00 | 0.00 |
| February | 211.68 | 158.80 | 208.06 | 127.03 | 81.03 | 0.00 | 0.00 |
| March | 105.39 | 130.89 | 127.38 | 36.29 | 91.09 | 0.00 | 0.00 |
| April | 299.16 | 113.73 | 263.74 | 117.46 | 146.27 | 0.00 | 0.00 |
| May | 229.63 | 97.99 | 218.16 | 69.30 | 148.86 | 0.00 | 0.00 |
| June | 222.48 | 76.98 | 204.13 | 50.02 | 154.11 | 0.00 | 0.00 |
| July | 258.28 | 71.74 | 220.70 | 69.39 | 151.32 | 0.00 | 0.00 |
| August | 317.34 | 78.15 | 256.61 | 114.59 | 142.02 | 0.00 | 0.00 |
| September | 380.47 | 98.24 | 309.50 | 183.14 | 126.36 | 0.00 | 0.00 |
| October | 223.70 | 123.41 | 202.81 | 115.69 | 87.12 | 0.00 | 0.00 |
| November | 148.66 | 148.54 | 148.54 | 90.33 | 58.21 | 0.00 | 0.00 |
| December | 112.93 | 185.88 | 117.68 | 75.38 | 42.30 | 0.00 | 0.00 |
| Annual Sum or Average | 222.91 | 120.42 | 203.66 | 96.18 | 107.48 | 0.00 | 0.00 |
| Minimum of Months | 105.39 | 71.74 | 117.68 | 36.29 | 42.30 | 0.00 | 0.00 |
| Maximum of Months | 380.47 | 185.88 | 309.50 | 183.14 | 154.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 5.54 | 27.84 | 9.64 | 3.86 | 5.79 | 0.00 | 0.00 |
| February | 9.32 | 26.28 | 14.47 | 5.37 | 9.11 | 0.00 | 0.00 |
| March | 9.31 | 21.15 | 15.07 | 2.96 | 12.11 | 0.00 | 0.00 |
| April | 42.19 | 17.72 | 40.37 | 18.92 | 21.45 | 0.00 | 0.00 |
| May | 43.17 | 15.33 | 42.53 | 18.53 | 24.00 | 0.00 | 0.00 |
| June | 44.88 | 12.55 | 42.16 | 16.86 | 25.30 | 0.00 | 0.00 |
| July | 47.64 | 11.72 | 43.04 | 18.31 | 24.73 | 0.00 | 0.00 |
| August | 46.48 | 12.64 | 40.79 | 19.49 | 21.29 | 0.00 | 0.00 |
| September | 40.85 | 15.81 | 36.59 | 19.41 | 17.18 | 0.00 | 0.00 |
| October | 16.00 | 20.23 | 17.89 | 7.52 | 10.37 | 0.00 | 0.00 |
| November | 5.31 | 24.69 | 9.20 | 3.12 | 6.08 | 0.00 | 0.00 |
| December | 3.38 | 30.43 | 6.83 | 2.53 | 4.29 | 0.00 | 0.00 |
| Annual Sum or Average | 26.23 | 19.67 | 26.59 | 11.42 | 15.17 | 0.00 | 0.00 |
| Minimum of Months | 3.38 | 11.72 | 6.83 | 2.53 | 4.29 | 0.00 | 0.00 |
| Maximum of Months | 47.64 | 30.43 | 43.04 | 19.49 | 25.30 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 18.16 | 73.82 | 28.73 | 11.48 | 17.24 | 0.00 | 0.00 |
| February | 30.60 | 69.48 | 43.11 | 15.99 | 27.12 | 0.00 | 0.00 |
| March | 31.16 | 56.11 | 44.90 | 8.82 | 36.08 | 0.00 | 0.00 |
| April | 132.04 | 47.31 | 120.22 | 56.35 | 63.87 | 0.00 | 0.00 |
| May | 134.26 | 41.79 | 126.67 | 55.18 | 71.49 | 0.00 | 0.00 |
| June | 138.04 | 35.09 | 125.55 | 50.20 | 75.35 | 0.00 | 0.00 |
| July | 144.76 | 34.00 | 128.17 | 54.52 | 73.65 | 0.00 | 0.00 |
| August | 140.02 | 37.49 | 121.47 | 58.06 | 63.41 | 0.00 | 0.00 |
| September | 122.62 | 47.05 | 108.97 | 57.81 | 51.16 | 0.00 | 0.00 |
| October | 48.88 | 57.69 | 53.28 | 22.38 | 30.90 | 0.00 | 0.00 |
| November | 17.10 | 67.24 | 27.40 | 9.28 | 18.12 | 0.00 | 0.00 |
| December | 11.05 | 81.61 | 20.33 | 7.54 | 12.79 | 0.00 | 0.00 |
| Annual Sum or Average | 80.90 | 53.98 | 79.18 | 34.01 | 45.17 | 0.00 | 0.00 |
| Minimum of Months | 11.05 | 34.00 | 20.33 | 7.54 | 12.79 | 0.00 | 0.00 |
| Maximum of Months | 144.76 | 81.61 | 128.17 | 58.06 | 75.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 5.17 | 30.34 | 9.64 | 3.86 | 5.79 | 0.00 | 0.00 |
| February | 8.80 | 28.50 | 14.47 | 5.37 | 9.11 | 0.00 | 0.00 |
| March | 8.64 | 22.96 | 15.07 | 2.96 | 12.11 | 0.00 | 0.00 |
| April | 41.07 | 19.25 | 40.37 | 18.92 | 21.45 | 0.00 | 0.00 |
| May | 41.63 | 17.12 | 42.53 | 18.53 | 24.00 | 0.00 | 0.00 |
| June | 43.69 | 13.71 | 42.16 | 16.86 | 25.30 | 0.00 | 0.00 |
| July | 46.78 | 12.61 | 43.04 | 18.31 | 24.73 | 0.00 | 0.00 |
| August | 45.58 | 13.64 | 40.79 | 19.49 | 21.29 | 0.00 | 0.00 |
| September | 39.47 | 17.61 | 36.59 | 19.41 | 17.18 | 0.00 | 0.00 |
| October | 15.05 | 22.86 | 17.89 | 7.52 | 10.37 | 0.00 | 0.00 |
| November | 4.93 | 27.11 | 9.20 | 3.12 | 6.08 | 0.00 | 0.00 |
| December | 3.14 | 33.10 | 6.83 | 2.53 | 4.29 | 0.00 | 0.00 |
| Annual Sum or Average | 25.39 | 21.53 | 26.59 | 11.42 | 15.17 | 0.00 | 0.00 |
| Minimum of Months | 3.14 | 12.61 | 6.83 | 2.53 | 4.29 | 0.00 | 0.00 |
| Maximum of Months | 46.78 | 33.10 | 43.04 | 19.49 | 25.30 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.512575E+09 | 0.715478E+09 | 0.562455E+09 | 0.329937E+09 | 0.232518E+09 | 0.00 | 0.00 |
| February | 0.652736E+09 | 0.622652E+09 | 0.672059E+09 | 0.378985E+09 | 0.293074E+09 | 0.00 | 0.00 |
| March | 0.402447E+09 | 0.559553E+09 | 0.509517E+09 | 0.129568E+09 | 0.379949E+09 | 0.00 | 0.00 |
| April | 0.120429E+10 | 0.455528E+09 | 0.106694E+10 | 0.456336E+09 | 0.610608E+09 | 0.00 | 0.00 |
| May | 0.111779E+10 | 0.404789E+09 | 0.104893E+10 | 0.373976E+09 | 0.674959E+09 | 0.00 | 0.00 |
| June | 0.113266E+10 | 0.318645E+09 | 0.101559E+10 | 0.330387E+09 | 0.685198E+09 | 0.00 | 0.00 |
| July | 0.129166E+10 | 0.313565E+09 | 0.110311E+10 | 0.411713E+09 | 0.691401E+09 | 0.00 | 0.00 |
| August | 0.135287E+10 | 0.353201E+09 | 0.111699E+10 | 0.492745E+09 | 0.624242E+09 | 0.00 | 0.00 |
| September | 0.135742E+10 | 0.438969E+09 | 0.113882E+10 | 0.626826E+09 | 0.511991E+09 | 0.00 | 0.00 |
| October | 0.762988E+09 | 0.555160E+09 | 0.727890E+09 | 0.376502E+09 | 0.351388E+09 | 0.00 | 0.00 |
| November | 0.444386E+09 | 0.633667E+09 | 0.481758E+09 | 0.262620E+09 | 0.219138E+09 | 0.00 | 0.00 |
| December | 0.313477E+09 | 0.815407E+09 | 0.371349E+09 | 0.213593E+09 | 0.157756E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.105453E+11 | 0.618661E+10 | 0.981541E+10 | 0.438319E+10 | 0.543222E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.313477E+09 | 0.313565E+09 | 0.371349E+09 | 0.129568E+09 | 0.157756E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.135742E+10 | 0.815407E+09 | 0.113882E+10 | 0.626826E+09 | 0.691401E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 60409246.17 | 0.759026E+09 | 0.185881E+09 | 34499043.26 | 0.151382E+09 | 0.00 | 0.00 |
| February | 0.151140E+09 | 0.640462E+09 | 0.281953E+09 | 71663277.87 | 0.210289E+09 | 0.00 | 0.00 |
| March | 0.179858E+09 | 0.566790E+09 | 0.341854E+09 | 32361586.63 | 0.309492E+09 | 0.00 | 0.00 |
| April | 0.620969E+09 | 0.432494E+09 | 0.657100E+09 | 0.153359E+09 | 0.503741E+09 | 0.00 | 0.00 |
| May | 0.763099E+09 | 0.367289E+09 | 0.819318E+09 | 0.206714E+09 | 0.612604E+09 | 0.00 | 0.00 |
| June | 0.886111E+09 | 0.290848E+09 | 0.863281E+09 | 0.223776E+09 | 0.639505E+09 | 0.00 | 0.00 |
| July | 0.936803E+09 | 0.289391E+09 | 0.882146E+09 | 0.246801E+09 | 0.635345E+09 | 0.00 | 0.00 |
| August | 0.765171E+09 | 0.327814E+09 | 0.722128E+09 | 0.191503E+09 | 0.530625E+09 | 0.00 | 0.00 |
| September | 0.550311E+09 | 0.406882E+09 | 0.551158E+09 | 0.152263E+09 | 0.398894E+09 | 0.00 | 0.00 |
| October | 0.237566E+09 | 0.535132E+09 | 0.326660E+09 | 66630123.19 | 0.260030E+09 | 0.00 | 0.00 |
| November | 68754779.45 | 0.650716E+09 | 0.179298E+09 | 28481825.66 | 0.150816E+09 | 0.00 | 0.00 |
| December | 16100270.60 | 0.851439E+09 | 0.114239E+09 | 11687166.48 | 0.102552E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.523629E+10 | 0.611828E+10 | 0.592502E+10 | 0.141974E+10 | 0.450528E+10 | 0.00 | 0.00 |
| Minimum of Months | 16100270.60 | 0.289391E+09 | 0.114239E+09 | 11687166.48 | 0.102552E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.936803E+09 | 0.851439E+09 | 0.882146E+09 | 0.246801E+09 | 0.639505E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.534458E+09 | 0.638016E+09 | 0.564520E+09 | 0.338477E+09 | 0.226043E+09 | 0.00 | 0.00 |
| February | 0.636895E+09 | 0.553768E+09 | 0.649276E+09 | 0.361446E+09 | 0.287831E+09 | 0.00 | 0.00 |
| March | 0.423700E+09 | 0.502219E+09 | 0.509436E+09 | 0.130254E+09 | 0.379182E+09 | 0.00 | 0.00 |
| April | 0.125498E+10 | 0.440820E+09 | 0.111965E+10 | 0.508832E+09 | 0.610816E+09 | 0.00 | 0.00 |
| May | 0.111252E+10 | 0.405301E+09 | 0.105906E+10 | 0.392409E+09 | 0.666654E+09 | 0.00 | 0.00 |
| June | 0.107262E+10 | 0.326850E+09 | 0.984467E+09 | 0.311743E+09 | 0.672723E+09 | 0.00 | 0.00 |
| July | 0.122036E+10 | 0.329745E+09 | 0.107150E+10 | 0.390187E+09 | 0.681312E+09 | 0.00 | 0.00 |
| August | 0.135659E+10 | 0.370092E+09 | 0.114255E+10 | 0.524491E+09 | 0.618056E+09 | 0.00 | 0.00 |
| September | 0.140924E+10 | 0.452114E+09 | 0.119745E+10 | 0.684358E+09 | 0.513095E+09 | 0.00 | 0.00 |
| October | 0.778954E+09 | 0.558513E+09 | 0.742881E+09 | 0.393756E+09 | 0.349125E+09 | 0.00 | 0.00 |
| November | 0.455993E+09 | 0.591305E+09 | 0.484400E+09 | 0.267814E+09 | 0.216586E+09 | 0.00 | 0.00 |
| December | 0.355778E+09 | 0.717164E+09 | 0.391403E+09 | 0.230174E+09 | 0.161228E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106121E+11 | 0.588591E+10 | 0.991659E+10 | 0.453394E+10 | 0.538265E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.355778E+09 | 0.326850E+09 | 0.391403E+09 | 0.130254E+09 | 0.161228E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.140924E+10 | 0.717164E+09 | 0.119745E+10 | 0.684358E+09 | 0.681312E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 52961823.18 | 0.747972E+09 | 0.187946E+09 | 43038899.42 | 0.144907E+09 | 0.00 | 0.00 |
| February | 0.106113E+09 | 0.626941E+09 | 0.259170E+09 | 54124494.36 | 0.205046E+09 | 0.00 | 0.00 |
| March | 0.177750E+09 | 0.561484E+09 | 0.341773E+09 | 33047677.58 | 0.308725E+09 | 0.00 | 0.00 |
| April | 0.675458E+09 | 0.416537E+09 | 0.709804E+09 | 0.205854E+09 | 0.503949E+09 | 0.00 | 0.00 |
| May | 0.771845E+09 | 0.359601E+09 | 0.829447E+09 | 0.225147E+09 | 0.604299E+09 | 0.00 | 0.00 |
| June | 0.845157E+09 | 0.285106E+09 | 0.832162E+09 | 0.205132E+09 | 0.627030E+09 | 0.00 | 0.00 |
| July | 0.890219E+09 | 0.284694E+09 | 0.850531E+09 | 0.225275E+09 | 0.625256E+09 | 0.00 | 0.00 |
| August | 0.790859E+09 | 0.319405E+09 | 0.747689E+09 | 0.223250E+09 | 0.524440E+09 | 0.00 | 0.00 |
| September | 0.606728E+09 | 0.392501E+09 | 0.609794E+09 | 0.209796E+09 | 0.399998E+09 | 0.00 | 0.00 |
| October | 0.246962E+09 | 0.523297E+09 | 0.341651E+09 | 83884359.61 | 0.257767E+09 | 0.00 | 0.00 |
| November | 59834922.83 | 0.636391E+09 | 0.181940E+09 | 33676090.54 | 0.148264E+09 | 0.00 | 0.00 |
| December | 22266163.43 | 0.827259E+09 | 0.134293E+09 | 28268796.97 | 0.106024E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.524616E+10 | 0.598119E+10 | 0.602620E+10 | 0.157049E+10 | 0.445571E+10 | 0.00 | 0.00 |
| Minimum of Months | 22266163.43 | 0.284694E+09 | 0.134293E+09 | 28268796.97 | 0.106024E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.890219E+09 | 0.827259E+09 | 0.850531E+09 | 0.225275E+09 | 0.627030E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 7204692.79 | 0.485350E+09 | 80287531.65 | 0.00 | 80287531.65 | 0.00 | 0.00 |
| February | 19677235.73 | 0.404166E+09 | 0.113240E+09 | 0.00 | 0.113240E+09 | 0.00 | 0.00 |
| March | 69243359.03 | 0.357692E+09 | 0.173511E+09 | 2459.32 | 0.173509E+09 | 0.00 | 0.00 |
| April | 0.205132E+09 | 0.265983E+09 | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.00 | 0.00 |
| May | 0.267069E+09 | 0.221293E+09 | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.00 | 0.00 |
| June | 0.336693E+09 | 0.176825E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
| July | 0.340375E+09 | 0.175749E+09 | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.00 | 0.00 |
| August | 0.260435E+09 | 0.199866E+09 | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.00 | 0.00 |
| September | 0.167547E+09 | 0.256431E+09 | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.00 | 0.00 |
| October | 68353822.02 | 0.335561E+09 | 0.141972E+09 | 0.00 | 0.141972E+09 | 0.00 | 0.00 |
| November | 11220218.20 | 0.407681E+09 | 82552649.24 | 0.00 | 82552649.24 | 0.00 | 0.00 |
| December | 383560.52 | 0.530135E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.175333E+10 | 0.381673E+10 | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.00 | 0.00 |
| Minimum of Months | 383560.52 | 0.175749E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Maximum of Months | 0.340375E+09 | 0.530135E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 7200972.97 | 0.485351E+09 | 80287531.65 | 0.00 | 80287531.65 | 0.00 | 0.00 |
| February | 19669951.18 | 0.404132E+09 | 0.113240E+09 | 0.00 | 0.113240E+09 | 0.00 | 0.00 |
| March | 69232972.70 | 0.357680E+09 | 0.173511E+09 | 2459.32 | 0.173509E+09 | 0.00 | 0.00 |
| April | 0.204935E+09 | 0.266054E+09 | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.00 | 0.00 |
| May | 0.266938E+09 | 0.221273E+09 | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.00 | 0.00 |
| June | 0.336760E+09 | 0.176641E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
| July | 0.340111E+09 | 0.175827E+09 | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.00 | 0.00 |
| August | 0.260205E+09 | 0.199990E+09 | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.00 | 0.00 |
| September | 0.167073E+09 | 0.256965E+09 | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.00 | 0.00 |
| October | 68286828.53 | 0.335596E+09 | 0.141972E+09 | 0.00 | 0.141972E+09 | 0.00 | 0.00 |
| November | 11215381.75 | 0.407675E+09 | 82552649.24 | 0.00 | 82552649.24 | 0.00 | 0.00 |
| December | 382779.20 | 0.530166E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.175201E+10 | 0.381735E+10 | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.00 | 0.00 |
| Minimum of Months | 382779.20 | 0.175827E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Maximum of Months | 0.340111E+09 | 0.530166E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.460154E+09 | 0.438077E+09 | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.00 | 0.00 |
| February | 0.521493E+09 | 0.381644E+09 | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.00 | 0.00 |
| March | 0.290751E+09 | 0.347172E+09 | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.00 | 0.00 |
| April | 0.797625E+09 | 0.286533E+09 | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.00 | 0.00 |
| May | 0.632033E+09 | 0.260254E+09 | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.00 | 0.00 |
| June | 0.588768E+09 | 0.202109E+09 | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.00 | 0.00 |
| July | 0.701497E+09 | 0.198679E+09 | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.00 | 0.00 |
| August | 0.857011E+09 | 0.219908E+09 | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.00 | 0.00 |
| September | 0.988663E+09 | 0.273848E+09 | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.00 | 0.00 |
| October | 0.601159E+09 | 0.348074E+09 | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.00 | 0.00 |
| November | 0.390233E+09 | 0.389439E+09 | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.00 | 0.00 |
| December | 0.306172E+09 | 0.499727E+09 | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.713556E+10 | 0.384546E+10 | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.290751E+09 | 0.198679E+09 | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.988663E+09 | 0.499727E+09 | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.460943E+09 | 0.435756E+09 | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.00 | 0.00 |
| February | 0.522306E+09 | 0.379614E+09 | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.00 | 0.00 |
| March | 0.291383E+09 | 0.345584E+09 | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.00 | 0.00 |
| April | 0.797024E+09 | 0.286899E+09 | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.00 | 0.00 |
| May | 0.630896E+09 | 0.261260E+09 | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.00 | 0.00 |
| June | 0.587646E+09 | 0.203026E+09 | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.00 | 0.00 |
| July | 0.700382E+09 | 0.199692E+09 | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.00 | 0.00 |
| August | 0.856153E+09 | 0.220852E+09 | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.00 | 0.00 |
| September | 0.987971E+09 | 0.274763E+09 | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.00 | 0.00 |
| October | 0.600817E+09 | 0.348666E+09 | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.00 | 0.00 |
| November | 0.390564E+09 | 0.388133E+09 | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.00 | 0.00 |
| December | 0.306673E+09 | 0.497184E+09 | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.713276E+10 | 0.384143E+10 | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.291383E+09 | 0.199692E+09 | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.987971E+09 | 0.497184E+09 | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.498309E+09 | 0.749630E+09 | 0.562455E+09 | 0.329937E+09 | 0.232518E+09 | 0.00 | 0.00 |
| February | 0.635373E+09 | 0.657323E+09 | 0.672059E+09 | 0.378985E+09 | 0.293074E+09 | 0.00 | 0.00 |
| March | 0.382304E+09 | 0.594536E+09 | 0.509517E+09 | 0.129568E+09 | 0.379949E+09 | 0.00 | 0.00 |
| April | 0.115479E+10 | 0.512998E+09 | 0.106694E+10 | 0.456336E+09 | 0.610608E+09 | 0.00 | 0.00 |
| May | 0.106460E+10 | 0.457616E+09 | 0.104893E+10 | 0.373976E+09 | 0.674959E+09 | 0.00 | 0.00 |
| June | 0.109670E+10 | 0.350154E+09 | 0.101559E+10 | 0.330387E+09 | 0.685198E+09 | 0.00 | 0.00 |
| July | 0.126829E+10 | 0.331790E+09 | 0.110311E+10 | 0.411713E+09 | 0.691401E+09 | 0.00 | 0.00 |
| August | 0.133748E+10 | 0.365653E+09 | 0.111699E+10 | 0.492745E+09 | 0.624242E+09 | 0.00 | 0.00 |
| September | 0.134271E+10 | 0.454535E+09 | 0.113882E+10 | 0.626826E+09 | 0.511991E+09 | 0.00 | 0.00 |
| October | 0.746353E+09 | 0.589453E+09 | 0.727890E+09 | 0.376502E+09 | 0.351388E+09 | 0.00 | 0.00 |
| November | 0.434207E+09 | 0.661085E+09 | 0.481758E+09 | 0.262620E+09 | 0.219138E+09 | 0.00 | 0.00 |
| December | 0.306332E+09 | 0.846557E+09 | 0.371349E+09 | 0.213593E+09 | 0.157756E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.102674E+11 | 0.657133E+10 | 0.981541E+10 | 0.438319E+10 | 0.543222E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.306332E+09 | 0.331790E+09 | 0.371349E+09 | 0.129568E+09 | 0.157756E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.134271E+10 | 0.846557E+09 | 0.113882E+10 | 0.626826E+09 | 0.691401E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 55120490.53 | 0.793295E+09 | 0.185881E+09 | 34499043.26 | 0.151382E+09 | 0.00 | 0.00 |
| February | 0.142089E+09 | 0.671830E+09 | 0.281953E+09 | 71663277.87 | 0.210289E+09 | 0.00 | 0.00 |
| March | 0.164298E+09 | 0.600377E+09 | 0.341854E+09 | 32361586.63 | 0.309492E+09 | 0.00 | 0.00 |
| April | 0.575977E+09 | 0.481931E+09 | 0.657100E+09 | 0.153359E+09 | 0.503741E+09 | 0.00 | 0.00 |
| May | 0.701208E+09 | 0.419998E+09 | 0.819318E+09 | 0.206714E+09 | 0.612604E+09 | 0.00 | 0.00 |
| June | 0.835752E+09 | 0.328180E+09 | 0.863281E+09 | 0.223776E+09 | 0.639505E+09 | 0.00 | 0.00 |
| July | 0.905551E+09 | 0.310763E+09 | 0.882146E+09 | 0.246801E+09 | 0.635345E+09 | 0.00 | 0.00 |
| August | 0.742529E+09 | 0.348978E+09 | 0.722128E+09 | 0.191503E+09 | 0.530625E+09 | 0.00 | 0.00 |
| September | 0.524162E+09 | 0.444354E+09 | 0.551158E+09 | 0.152263E+09 | 0.398894E+09 | 0.00 | 0.00 |
| October | 0.222500E+09 | 0.570965E+09 | 0.326660E+09 | 66630123.19 | 0.260030E+09 | 0.00 | 0.00 |
| November | 64315443.52 | 0.677131E+09 | 0.179298E+09 | 28481825.66 | 0.150816E+09 | 0.00 | 0.00 |
| December | 14390887.26 | 0.884144E+09 | 0.114239E+09 | 11687166.48 | 0.102552E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.494789E+10 | 0.653194E+10 | 0.592502E+10 | 0.141974E+10 | 0.450528E+10 | 0.00 | 0.00 |
| Minimum of Months | 14390887.26 | 0.310763E+09 | 0.114239E+09 | 11687166.48 | 0.102552E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.905551E+09 | 0.884144E+09 | 0.882146E+09 | 0.246801E+09 | 0.639505E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.499105E+09 | 0.747058E+09 | 0.564520E+09 | 0.338477E+09 | 0.226043E+09 | 0.00 | 0.00 |
| February | 0.597390E+09 | 0.649819E+09 | 0.649276E+09 | 0.361446E+09 | 0.287831E+09 | 0.00 | 0.00 |
| March | 0.381767E+09 | 0.590615E+09 | 0.509436E+09 | 0.130254E+09 | 0.379182E+09 | 0.00 | 0.00 |
| April | 0.120438E+10 | 0.495058E+09 | 0.111965E+10 | 0.508832E+09 | 0.610816E+09 | 0.00 | 0.00 |
| May | 0.106631E+10 | 0.444594E+09 | 0.105906E+10 | 0.392409E+09 | 0.666654E+09 | 0.00 | 0.00 |
| June | 0.104952E+10 | 0.338128E+09 | 0.984467E+09 | 0.311743E+09 | 0.672723E+09 | 0.00 | 0.00 |
| July | 0.121860E+10 | 0.320359E+09 | 0.107150E+10 | 0.390187E+09 | 0.681312E+09 | 0.00 | 0.00 |
| August | 0.135986E+10 | 0.348738E+09 | 0.114255E+10 | 0.524491E+09 | 0.618056E+09 | 0.00 | 0.00 |
| September | 0.140528E+10 | 0.438338E+09 | 0.119745E+10 | 0.684358E+09 | 0.513095E+09 | 0.00 | 0.00 |
| October | 0.762665E+09 | 0.584666E+09 | 0.742881E+09 | 0.393756E+09 | 0.349125E+09 | 0.00 | 0.00 |
| November | 0.435981E+09 | 0.657119E+09 | 0.484400E+09 | 0.267814E+09 | 0.216586E+09 | 0.00 | 0.00 |
| December | 0.332590E+09 | 0.842592E+09 | 0.391403E+09 | 0.230174E+09 | 0.161228E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.103134E+11 | 0.645708E+10 | 0.991659E+10 | 0.453394E+10 | 0.538265E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.332590E+09 | 0.320359E+09 | 0.391403E+09 | 0.130254E+09 | 0.161228E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.140528E+10 | 0.842592E+09 | 0.119745E+10 | 0.684358E+09 | 0.681312E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 47738974.27 | 0.782266E+09 | 0.187946E+09 | 43038899.42 | 0.144907E+09 | 0.00 | 0.00 |
| February | 97100857.02 | 0.658012E+09 | 0.259170E+09 | 54124494.36 | 0.205046E+09 | 0.00 | 0.00 |
| March | 0.162499E+09 | 0.594678E+09 | 0.341773E+09 | 33047677.58 | 0.308725E+09 | 0.00 | 0.00 |
| April | 0.625230E+09 | 0.465613E+09 | 0.709804E+09 | 0.205854E+09 | 0.503949E+09 | 0.00 | 0.00 |
| May | 0.706355E+09 | 0.412397E+09 | 0.829447E+09 | 0.225147E+09 | 0.604299E+09 | 0.00 | 0.00 |
| June | 0.794330E+09 | 0.321999E+09 | 0.832162E+09 | 0.205132E+09 | 0.627030E+09 | 0.00 | 0.00 |
| July | 0.861244E+09 | 0.304827E+09 | 0.850531E+09 | 0.225275E+09 | 0.625256E+09 | 0.00 | 0.00 |
| August | 0.769838E+09 | 0.337631E+09 | 0.747689E+09 | 0.223250E+09 | 0.524440E+09 | 0.00 | 0.00 |
| September | 0.579505E+09 | 0.425394E+09 | 0.609794E+09 | 0.209796E+09 | 0.399998E+09 | 0.00 | 0.00 |
| October | 0.230527E+09 | 0.558522E+09 | 0.341651E+09 | 83884359.61 | 0.257767E+09 | 0.00 | 0.00 |
| November | 55073805.37 | 0.662092E+09 | 0.181940E+09 | 33676090.54 | 0.148264E+09 | 0.00 | 0.00 |
| December | 19916466.79 | 0.859106E+09 | 0.134293E+09 | 28268796.97 | 0.106024E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.494936E+10 | 0.638254E+10 | 0.602620E+10 | 0.157049E+10 | 0.445571E+10 | 0.00 | 0.00 |
| Minimum of Months | 19916466.79 | 0.304827E+09 | 0.134293E+09 | 28268796.97 | 0.106024E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.861244E+09 | 0.859106E+09 | 0.850531E+09 | 0.225275E+09 | 0.627030E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 5648447.67 | 0.506658E+09 | 80287531.65 | 0.00 | 80287531.65 | 0.00 | 0.00 |
| February | 16177245.05 | 0.423191E+09 | 0.113240E+09 | 0.00 | 0.113240E+09 | 0.00 | 0.00 |
| March | 61750674.26 | 0.377906E+09 | 0.173511E+09 | 2459.32 | 0.173509E+09 | 0.00 | 0.00 |
| April | 0.179770E+09 | 0.298603E+09 | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.00 | 0.00 |
| May | 0.228474E+09 | 0.255920E+09 | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.00 | 0.00 |
| June | 0.308795E+09 | 0.197514E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
| July | 0.325545E+09 | 0.186047E+09 | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.00 | 0.00 |
| August | 0.250357E+09 | 0.209696E+09 | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.00 | 0.00 |
| September | 0.154678E+09 | 0.277418E+09 | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.00 | 0.00 |
| October | 59505595.96 | 0.361946E+09 | 0.141972E+09 | 0.00 | 0.141972E+09 | 0.00 | 0.00 |
| November | 9453931.08 | 0.424279E+09 | 82552649.24 | 0.00 | 82552649.24 | 0.00 | 0.00 |
| December | 194226.89 | 0.550379E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.160035E+10 | 0.406956E+10 | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.00 | 0.00 |
| Minimum of Months | 194226.89 | 0.186047E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Maximum of Months | 0.325545E+09 | 0.550379E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 5642886.43 | 0.506659E+09 | 80287531.65 | 0.00 | 80287531.65 | 0.00 | 0.00 |
| February | 16165771.62 | 0.423144E+09 | 0.113240E+09 | 0.00 | 0.113240E+09 | 0.00 | 0.00 |
| March | 61733439.22 | 0.377879E+09 | 0.173511E+09 | 2459.32 | 0.173509E+09 | 0.00 | 0.00 |
| April | 0.179288E+09 | 0.298987E+09 | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.00 | 0.00 |
| May | 0.228058E+09 | 0.256126E+09 | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.00 | 0.00 |
| June | 0.308768E+09 | 0.197440E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
| July | 0.325493E+09 | 0.186010E+09 | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.00 | 0.00 |
| August | 0.250285E+09 | 0.209673E+09 | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.00 | 0.00 |
| September | 0.154423E+09 | 0.277606E+09 | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.00 | 0.00 |
| October | 59376529.32 | 0.362067E+09 | 0.141972E+09 | 0.00 | 0.141972E+09 | 0.00 | 0.00 |
| November | 9447046.26 | 0.424264E+09 | 82552649.24 | 0.00 | 82552649.24 | 0.00 | 0.00 |
| December | 193563.19 | 0.550423E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.159887E+10 | 0.407028E+10 | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.00 | 0.00 |
| Minimum of Months | 193563.19 | 0.186010E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Maximum of Months | 0.325493E+09 | 0.550423E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.450321E+09 | 0.460293E+09 | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.00 | 0.00 |
| February | 0.510509E+09 | 0.403026E+09 | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.00 | 0.00 |
| March | 0.278835E+09 | 0.368680E+09 | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.00 | 0.00 |
| April | 0.770374E+09 | 0.323808E+09 | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.00 | 0.00 |
| May | 0.604507E+09 | 0.295155E+09 | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.00 | 0.00 |
| June | 0.572460E+09 | 0.218810E+09 | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.00 | 0.00 |
| July | 0.691976E+09 | 0.207168E+09 | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.00 | 0.00 |
| August | 0.850754E+09 | 0.224878E+09 | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.00 | 0.00 |
| September | 0.982049E+09 | 0.280296E+09 | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.00 | 0.00 |
| October | 0.590921E+09 | 0.372067E+09 | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.00 | 0.00 |
| November | 0.382884E+09 | 0.410564E+09 | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.00 | 0.00 |
| December | 0.301148E+09 | 0.518403E+09 | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.698674E+10 | 0.408315E+10 | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.278835E+09 | 0.207168E+09 | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.982049E+09 | 0.518403E+09 | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.450284E+09 | 0.460297E+09 | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.00 | 0.00 |
| February | 0.510501E+09 | 0.402911E+09 | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.00 | 0.00 |
| March | 0.278801E+09 | 0.368660E+09 | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.00 | 0.00 |
| April | 0.770097E+09 | 0.324043E+09 | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.00 | 0.00 |
| May | 0.604306E+09 | 0.295228E+09 | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.00 | 0.00 |
| June | 0.572431E+09 | 0.218730E+09 | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.00 | 0.00 |
| July | 0.691927E+09 | 0.207134E+09 | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.00 | 0.00 |
| August | 0.850705E+09 | 0.224852E+09 | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.00 | 0.00 |
| September | 0.981973E+09 | 0.280316E+09 | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.00 | 0.00 |
| October | 0.590848E+09 | 0.372127E+09 | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.00 | 0.00 |
| November | 0.382861E+09 | 0.410542E+09 | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.00 | 0.00 |
| December | 0.301125E+09 | 0.518450E+09 | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.698586E+10 | 0.408329E+10 | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.278801E+09 | 0.207134E+09 | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.981973E+09 | 0.518450E+09 | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.500758E+09 | 0.715103E+09 | 0.562455E+09 | 0.329937E+09 | 0.232518E+09 | 0.00 | 0.00 |
| February | 0.635671E+09 | 0.628883E+09 | 0.672059E+09 | 0.378985E+09 | 0.293074E+09 | 0.00 | 0.00 |
| March | 0.385623E+09 | 0.566599E+09 | 0.509517E+09 | 0.129568E+09 | 0.379949E+09 | 0.00 | 0.00 |
| April | 0.115959E+10 | 0.468423E+09 | 0.106694E+10 | 0.456336E+09 | 0.610608E+09 | 0.00 | 0.00 |
| May | 0.107908E+10 | 0.407979E+09 | 0.104893E+10 | 0.373976E+09 | 0.674959E+09 | 0.00 | 0.00 |
| June | 0.110478E+10 | 0.312912E+09 | 0.101559E+10 | 0.330387E+09 | 0.685198E+09 | 0.00 | 0.00 |
| July | 0.126894E+10 | 0.301182E+09 | 0.110311E+10 | 0.411713E+09 | 0.691401E+09 | 0.00 | 0.00 |
| August | 0.133770E+10 | 0.332170E+09 | 0.111699E+10 | 0.492745E+09 | 0.624242E+09 | 0.00 | 0.00 |
| September | 0.135078E+10 | 0.405003E+09 | 0.113882E+10 | 0.626826E+09 | 0.511991E+09 | 0.00 | 0.00 |
| October | 0.755341E+09 | 0.533301E+09 | 0.727890E+09 | 0.376502E+09 | 0.351388E+09 | 0.00 | 0.00 |
| November | 0.435876E+09 | 0.627721E+09 | 0.481758E+09 | 0.262620E+09 | 0.219138E+09 | 0.00 | 0.00 |
| December | 0.307927E+09 | 0.813379E+09 | 0.371349E+09 | 0.213593E+09 | 0.157756E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.103221E+11 | 0.611266E+10 | 0.981541E+10 | 0.438319E+10 | 0.543222E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.307927E+09 | 0.301182E+09 | 0.371349E+09 | 0.129568E+09 | 0.157756E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.135078E+10 | 0.813379E+09 | 0.113882E+10 | 0.626826E+09 | 0.691401E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 57198411.32 | 0.760001E+09 | 0.185881E+09 | 34499043.26 | 0.151382E+09 | 0.00 | 0.00 |
| February | 0.144543E+09 | 0.644611E+09 | 0.281953E+09 | 71663277.87 | 0.210289E+09 | 0.00 | 0.00 |
| March | 0.168413E+09 | 0.573218E+09 | 0.341854E+09 | 32361586.63 | 0.309492E+09 | 0.00 | 0.00 |
| April | 0.579750E+09 | 0.450908E+09 | 0.657100E+09 | 0.153359E+09 | 0.503741E+09 | 0.00 | 0.00 |
| May | 0.719378E+09 | 0.379633E+09 | 0.819318E+09 | 0.206714E+09 | 0.612604E+09 | 0.00 | 0.00 |
| June | 0.850637E+09 | 0.294657E+09 | 0.863281E+09 | 0.223776E+09 | 0.639505E+09 | 0.00 | 0.00 |
| July | 0.913997E+09 | 0.283367E+09 | 0.882146E+09 | 0.246801E+09 | 0.635345E+09 | 0.00 | 0.00 |
| August | 0.751333E+09 | 0.314741E+09 | 0.722128E+09 | 0.191503E+09 | 0.530625E+09 | 0.00 | 0.00 |
| September | 0.543452E+09 | 0.389984E+09 | 0.551158E+09 | 0.152263E+09 | 0.398894E+09 | 0.00 | 0.00 |
| October | 0.231612E+09 | 0.528272E+09 | 0.326660E+09 | 66630123.19 | 0.260030E+09 | 0.00 | 0.00 |
| November | 66764038.89 | 0.645950E+09 | 0.179298E+09 | 28481825.66 | 0.150816E+09 | 0.00 | 0.00 |
| December | 15305625.74 | 0.849720E+09 | 0.114239E+09 | 11687166.48 | 0.102552E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.504238E+10 | 0.611506E+10 | 0.592502E+10 | 0.141974E+10 | 0.450528E+10 | 0.00 | 0.00 |
| Minimum of Months | 15305625.74 | 0.283367E+09 | 0.114239E+09 | 11687166.48 | 0.102552E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.913997E+09 | 0.849720E+09 | 0.882146E+09 | 0.246801E+09 | 0.639505E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.501529E+09 | 0.712545E+09 | 0.564520E+09 | 0.338477E+09 | 0.226043E+09 | 0.00 | 0.00 |
| February | 0.598075E+09 | 0.621317E+09 | 0.649276E+09 | 0.361446E+09 | 0.287831E+09 | 0.00 | 0.00 |
| March | 0.385539E+09 | 0.562678E+09 | 0.509436E+09 | 0.130254E+09 | 0.379182E+09 | 0.00 | 0.00 |
| April | 0.121068E+10 | 0.452600E+09 | 0.111965E+10 | 0.508832E+09 | 0.610816E+09 | 0.00 | 0.00 |
| May | 0.108187E+10 | 0.397098E+09 | 0.105906E+10 | 0.392409E+09 | 0.666654E+09 | 0.00 | 0.00 |
| June | 0.105813E+10 | 0.303674E+09 | 0.984467E+09 | 0.311743E+09 | 0.672723E+09 | 0.00 | 0.00 |
| July | 0.121987E+10 | 0.292667E+09 | 0.107150E+10 | 0.390187E+09 | 0.681312E+09 | 0.00 | 0.00 |
| August | 0.136070E+10 | 0.318804E+09 | 0.114255E+10 | 0.524491E+09 | 0.618056E+09 | 0.00 | 0.00 |
| September | 0.141357E+10 | 0.392731E+09 | 0.119745E+10 | 0.684358E+09 | 0.513095E+09 | 0.00 | 0.00 |
| October | 0.771362E+09 | 0.528611E+09 | 0.742881E+09 | 0.393756E+09 | 0.349125E+09 | 0.00 | 0.00 |
| November | 0.437639E+09 | 0.623599E+09 | 0.484400E+09 | 0.267814E+09 | 0.216586E+09 | 0.00 | 0.00 |
| December | 0.334167E+09 | 0.809289E+09 | 0.391403E+09 | 0.230174E+09 | 0.161228E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.103731E+11 | 0.601561E+10 | 0.991659E+10 | 0.453394E+10 | 0.538265E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.334167E+09 | 0.292667E+09 | 0.391403E+09 | 0.130254E+09 | 0.161228E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.141357E+10 | 0.809289E+09 | 0.119745E+10 | 0.684358E+09 | 0.681312E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 50579901.55 | 0.749633E+09 | 0.187946E+09 | 43038899.42 | 0.144907E+09 | 0.00 | 0.00 |
| February | 0.100745E+09 | 0.631570E+09 | 0.259170E+09 | 54124494.36 | 0.205046E+09 | 0.00 | 0.00 |
| March | 0.167089E+09 | 0.568195E+09 | 0.341773E+09 | 33047677.58 | 0.308725E+09 | 0.00 | 0.00 |
| April | 0.630290E+09 | 0.435350E+09 | 0.709804E+09 | 0.205854E+09 | 0.503949E+09 | 0.00 | 0.00 |
| May | 0.723192E+09 | 0.371187E+09 | 0.829447E+09 | 0.225147E+09 | 0.604299E+09 | 0.00 | 0.00 |
| June | 0.805870E+09 | 0.288861E+09 | 0.832162E+09 | 0.205132E+09 | 0.627030E+09 | 0.00 | 0.00 |
| July | 0.865738E+09 | 0.277605E+09 | 0.850531E+09 | 0.225275E+09 | 0.625256E+09 | 0.00 | 0.00 |
| August | 0.776642E+09 | 0.306292E+09 | 0.747689E+09 | 0.223250E+09 | 0.524440E+09 | 0.00 | 0.00 |
| September | 0.599223E+09 | 0.375528E+09 | 0.609794E+09 | 0.209796E+09 | 0.399998E+09 | 0.00 | 0.00 |
| October | 0.241176E+09 | 0.516192E+09 | 0.341651E+09 | 83884359.61 | 0.257767E+09 | 0.00 | 0.00 |
| November | 58438976.64 | 0.631702E+09 | 0.181940E+09 | 33676090.54 | 0.148264E+09 | 0.00 | 0.00 |
| December | 21789325.63 | 0.825421E+09 | 0.134293E+09 | 28268796.97 | 0.106024E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.504077E+10 | 0.597754E+10 | 0.602620E+10 | 0.157049E+10 | 0.445571E+10 | 0.00 | 0.00 |
| Minimum of Months | 21789325.63 | 0.277605E+09 | 0.134293E+09 | 28268796.97 | 0.106024E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.865738E+09 | 0.825421E+09 | 0.850531E+09 | 0.225275E+09 | 0.627030E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 6481168.41 | 0.485522E+09 | 80287531.65 | 0.00 | 80287531.65 | 0.00 | 0.00 |
| February | 17715773.25 | 0.406264E+09 | 0.113240E+09 | 0.00 | 0.113240E+09 | 0.00 | 0.00 |
| March | 64664980.34 | 0.361026E+09 | 0.173511E+09 | 2459.32 | 0.173509E+09 | 0.00 | 0.00 |
| April | 0.185122E+09 | 0.278244E+09 | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.00 | 0.00 |
| May | 0.244251E+09 | 0.229545E+09 | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.00 | 0.00 |
| June | 0.317926E+09 | 0.180733E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
| July | 0.330513E+09 | 0.173076E+09 | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.00 | 0.00 |
| August | 0.255561E+09 | 0.193394E+09 | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.00 | 0.00 |
| September | 0.168035E+09 | 0.244210E+09 | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.00 | 0.00 |
| October | 67621909.24 | 0.329023E+09 | 0.141972E+09 | 0.00 | 0.141972E+09 | 0.00 | 0.00 |
| November | 10803429.79 | 0.404276E+09 | 82552649.24 | 0.00 | 82552649.24 | 0.00 | 0.00 |
| December | 330053.44 | 0.528382E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.166903E+10 | 0.381370E+10 | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.00 | 0.00 |
| Minimum of Months | 330053.44 | 0.173076E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Maximum of Months | 0.330513E+09 | 0.528382E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 6467621.69 | 0.485510E+09 | 80287531.65 | 0.00 | 80287531.65 | 0.00 | 0.00 |
| February | 17681377.08 | 0.406183E+09 | 0.113240E+09 | 0.00 | 0.113240E+09 | 0.00 | 0.00 |
| March | 64609324.74 | 0.360998E+09 | 0.173511E+09 | 2459.32 | 0.173509E+09 | 0.00 | 0.00 |
| April | 0.184375E+09 | 0.278260E+09 | 0.273760E+09 | 1481688.00 | 0.272278E+09 | 0.00 | 0.00 |
| May | 0.243564E+09 | 0.229441E+09 | 0.354710E+09 | 18354078.71 | 0.336356E+09 | 0.00 | 0.00 |
| June | 0.317518E+09 | 0.180546E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
| July | 0.330050E+09 | 0.172958E+09 | 0.370163E+09 | 20932067.40 | 0.349231E+09 | 0.00 | 0.00 |
| August | 0.255104E+09 | 0.193282E+09 | 0.292438E+09 | 5665581.36 | 0.286772E+09 | 0.00 | 0.00 |
| September | 0.167286E+09 | 0.244323E+09 | 0.214566E+09 | 128987.26 | 0.214437E+09 | 0.00 | 0.00 |
| October | 67411460.55 | 0.328949E+09 | 0.141972E+09 | 0.00 | 0.141972E+09 | 0.00 | 0.00 |
| November | 10785341.97 | 0.404252E+09 | 82552649.24 | 0.00 | 82552649.24 | 0.00 | 0.00 |
| December | 328137.47 | 0.528411E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.166518E+10 | 0.381311E+10 | 0.253209E+10 | 69612121.87 | 0.246248E+10 | 0.00 | 0.00 |
| Minimum of Months | 328137.47 | 0.172958E+09 | 58092086.33 | 0.00 | 58092086.33 | 0.00 | 0.00 |
| Maximum of Months | 0.330050E+09 | 0.528411E+09 | 0.376800E+09 | 23047259.82 | 0.353753E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.453377E+09 | 0.436613E+09 | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.00 | 0.00 |
| February | 0.512176E+09 | 0.384339E+09 | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.00 | 0.00 |
| March | 0.282349E+09 | 0.350610E+09 | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.00 | 0.00 |
| April | 0.775961E+09 | 0.294798E+09 | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.00 | 0.00 |
| May | 0.615518E+09 | 0.262632E+09 | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.00 | 0.00 |
| June | 0.576945E+09 | 0.199794E+09 | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.00 | 0.00 |
| July | 0.692084E+09 | 0.192315E+09 | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.00 | 0.00 |
| August | 0.850209E+09 | 0.209475E+09 | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.00 | 0.00 |
| September | 0.986481E+09 | 0.254712E+09 | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.00 | 0.00 |
| October | 0.599332E+09 | 0.330587E+09 | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.00 | 0.00 |
| November | 0.385392E+09 | 0.385082E+09 | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.00 | 0.00 |
| December | 0.302510E+09 | 0.497841E+09 | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.703233E+10 | 0.379880E+10 | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.282349E+09 | 0.192315E+09 | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.986481E+09 | 0.497841E+09 | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.453289E+09 | 0.436580E+09 | 0.456861E+09 | 0.295438E+09 | 0.161423E+09 | 0.00 | 0.00 |
| February | 0.512107E+09 | 0.384178E+09 | 0.503346E+09 | 0.307321E+09 | 0.196024E+09 | 0.00 | 0.00 |
| March | 0.282268E+09 | 0.350562E+09 | 0.341174E+09 | 97208488.08 | 0.243966E+09 | 0.00 | 0.00 |
| April | 0.775431E+09 | 0.294777E+09 | 0.683604E+09 | 0.304459E+09 | 0.379145E+09 | 0.00 | 0.00 |
| May | 0.615032E+09 | 0.262457E+09 | 0.584327E+09 | 0.185616E+09 | 0.398711E+09 | 0.00 | 0.00 |
| June | 0.576674E+09 | 0.199542E+09 | 0.529104E+09 | 0.129659E+09 | 0.399446E+09 | 0.00 | 0.00 |
| July | 0.691790E+09 | 0.192138E+09 | 0.591131E+09 | 0.185844E+09 | 0.405287E+09 | 0.00 | 0.00 |
| August | 0.849951E+09 | 0.209328E+09 | 0.687296E+09 | 0.306907E+09 | 0.380389E+09 | 0.00 | 0.00 |
| September | 0.986167E+09 | 0.254641E+09 | 0.802226E+09 | 0.474691E+09 | 0.327534E+09 | 0.00 | 0.00 |
| October | 0.599162E+09 | 0.330534E+09 | 0.543202E+09 | 0.309872E+09 | 0.233331E+09 | 0.00 | 0.00 |
| November | 0.385328E+09 | 0.385026E+09 | 0.385013E+09 | 0.234138E+09 | 0.150875E+09 | 0.00 | 0.00 |
| December | 0.302463E+09 | 0.497869E+09 | 0.315202E+09 | 0.201905E+09 | 0.113296E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.702966E+10 | 0.379763E+10 | 0.642249E+10 | 0.303306E+10 | 0.338943E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.282268E+09 | 0.192138E+09 | 0.315202E+09 | 97208488.08 | 0.113296E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.986167E+09 | 0.497869E+09 | 0.802226E+09 | 0.474691E+09 | 0.405287E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 14835809.45 | 74558128.87 | 25833091.76 | 10327359.10 | 15505732.66 | 0.00 | 0.00 |
| February | 22558962.12 | 63565399.88 | 35016718.23 | 12987392.73 | 22029325.50 | 0.00 | 0.00 |
| March | 24937151.26 | 56642344.78 | 40375009.83 | 7929334.63 | 32445675.21 | 0.00 | 0.00 |
| April | 0.109361E+09 | 45934740.05 | 0.104631E+09 | 49040048.07 | 55590536.04 | 0.00 | 0.00 |
| May | 0.115624E+09 | 41061812.49 | 0.113915E+09 | 49620905.25 | 64294087.41 | 0.00 | 0.00 |
| June | 0.116331E+09 | 32538026.76 | 0.109266E+09 | 43691914.28 | 65574135.68 | 0.00 | 0.00 |
| July | 0.127611E+09 | 31401330.75 | 0.115266E+09 | 49032981.58 | 66233399.09 | 0.00 | 0.00 |
| August | 0.124486E+09 | 33847368.25 | 0.109239E+09 | 52210172.79 | 57029254.48 | 0.00 | 0.00 |
| September | 0.105873E+09 | 40987412.33 | 94836422.31 | 50310452.31 | 44525970.00 | 0.00 | 0.00 |
| October | 42845375.78 | 54194238.10 | 47913730.77 | 20128393.53 | 27785337.24 | 0.00 | 0.00 |
| November | 13762627.10 | 63988156.19 | 23848341.90 | 8080715.00 | 15767626.90 | 0.00 | 0.00 |
| December | 9065490.57 | 81511624.90 | 18284709.33 | 6783212.90 | 11501496.43 | 0.00 | 0.00 |
| Annual Sum or Average | 0.827290E+09 | 0.620231E+09 | 0.838425E+09 | 0.360143E+09 | 0.478283E+09 | 0.00 | 0.00 |
| Minimum of Months | 9065490.57 | 31401330.75 | 18284709.33 | 6783212.90 | 11501496.43 | 0.00 | 0.00 |
| Maximum of Months | 0.127611E+09 | 81511624.90 | 0.115266E+09 | 52210172.79 | 66233399.09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 48631448.58 | 0.197715E+09 | 76937376.17 | 30757445.51 | 46179930.67 | 0.00 | 0.00 |
| February | 74026874.19 | 0.168075E+09 | 0.104289E+09 | 38679687.63 | 65608813.63 | 0.00 | 0.00 |
| March | 83468006.91 | 0.150285E+09 | 0.120247E+09 | 23615531.84 | 96631295.30 | 0.00 | 0.00 |
| April | 0.342259E+09 | 0.122637E+09 | 0.311616E+09 | 0.146053E+09 | 0.165562E+09 | 0.00 | 0.00 |
| May | 0.359597E+09 | 0.111928E+09 | 0.339267E+09 | 0.147783E+09 | 0.191484E+09 | 0.00 | 0.00 |
| June | 0.357808E+09 | 90951295.98 | 0.325421E+09 | 0.130125E+09 | 0.195296E+09 | 0.00 | 0.00 |
| July | 0.387716E+09 | 91067160.92 | 0.343292E+09 | 0.146032E+09 | 0.197260E+09 | 0.00 | 0.00 |
| August | 0.375026E+09 | 0.100403E+09 | 0.325342E+09 | 0.155495E+09 | 0.169847E+09 | 0.00 | 0.00 |
| September | 0.317819E+09 | 0.121962E+09 | 0.282446E+09 | 0.149837E+09 | 0.132609E+09 | 0.00 | 0.00 |
| October | 0.130917E+09 | 0.154509E+09 | 0.142699E+09 | 59947365.16 | 82751649.05 | 0.00 | 0.00 |
| November | 44315248.11 | 0.174282E+09 | 71026297.15 | 24066380.26 | 46959916.89 | 0.00 | 0.00 |
| December | 29604650.16 | 0.218583E+09 | 54456414.77 | 20202096.11 | 34254318.66 | 0.00 | 0.00 |
| Annual Sum or Average | 0.255119E+10 | 0.170240E+10 | 0.249704E+10 | 0.107260E+10 | 0.142444E+10 | 0.00 | 0.00 |
| Minimum of Months | 29604650.16 | 90951295.98 | 54456414.77 | 20202096.11 | 34254318.66 | 0.00 | 0.00 |
| Maximum of Months | 0.387716E+09 | 0.218583E+09 | 0.343292E+09 | 0.155495E+09 | 0.197260E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 13842334.48 | 81257249.49 | 25833091.76 | 10327359.10 | 15505732.66 | 0.00 | 0.00 |
| February | 21282539.59 | 68935743.44 | 35016718.23 | 12987392.73 | 22029325.50 | 0.00 | 0.00 |
| March | 23129712.41 | 61482740.85 | 40375009.83 | 7929334.63 | 32445675.21 | 0.00 | 0.00 |
| April | 0.106455E+09 | 49908284.10 | 0.104631E+09 | 49040048.07 | 55590536.04 | 0.00 | 0.00 |
| May | 0.111489E+09 | 45859975.49 | 0.113915E+09 | 49620905.25 | 64294087.41 | 0.00 | 0.00 |
| June | 0.113244E+09 | 35534002.29 | 0.109266E+09 | 43691914.28 | 65574135.68 | 0.00 | 0.00 |
| July | 0.125283E+09 | 33765560.10 | 0.115266E+09 | 49032981.58 | 66233399.09 | 0.00 | 0.00 |
| August | 0.122069E+09 | 36534454.51 | 0.109239E+09 | 52210172.79 | 57029254.48 | 0.00 | 0.00 |
| September | 0.102294E+09 | 45633567.72 | 94836422.31 | 50310452.31 | 44525970.00 | 0.00 | 0.00 |
| October | 40312451.46 | 61223000.40 | 47913730.77 | 20128393.53 | 27785337.24 | 0.00 | 0.00 |
| November | 12773871.40 | 70259549.77 | 23848341.90 | 8080715.00 | 15767626.90 | 0.00 | 0.00 |
| December | 8423519.32 | 88667497.02 | 18284709.33 | 6783212.90 | 11501496.43 | 0.00 | 0.00 |
| Annual Sum or Average | 0.800599E+09 | 0.679062E+09 | 0.838425E+09 | 0.360143E+09 | 0.478283E+09 | 0.00 | 0.00 |
| Minimum of Months | 8423519.32 | 33765560.10 | 18284709.33 | 6783212.90 | 11501496.43 | 0.00 | 0.00 |
| Maximum of Months | 0.125283E+09 | 88667497.02 | 0.115266E+09 | 52210172.79 | 66233399.09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 4.18 | 3.23 | 2.03 | 1.05 | -4.0 | 28.28 | 62.93 | 0.00 |
| February | 4.25 | 3.55 | 2.74 | 1.60 | -5.0 | 43.80 | 86.73 | 0.02 |
| March | 5.90 | 4.45 | 2.76 | 1.18 | -1.9 | 68.95 | 35.00 | 0.00 |
| April | 8.96 | 6.24 | 3.38 | 1.56 | -0.7 | 96.13 | 186.12 | 0.00 |
| May | 9.99 | 8.07 | 6.28 | 3.35 | -0.9 | 110.92 | 199.68 | 0.02 |
| June | 13.31 | 11.27 | 9.70 | 3.33 | 3.35 | 121.69 | 199.28 | 0.00 |
| July | 15.02 | 12.39 | 10.49 | 3.21 | 4.49 | 111.91 | 220.83 | 0.00 |
| August | 15.65 | 12.75 | 10.65 | 2.92 | 3.95 | 91.47 | 211.91 | 0.00 |
| September | 13.43 | 11.01 | 9.10 | 2.64 | 1.43 | 68.72 | 198.32 | 0.01 |
| October | 9.33 | 8.03 | 6.81 | 1.97 | -1.0 | 48.92 | 91.86 | 0.04 |
| November | 6.66 | 5.66 | 4.54 | 2.05 | -2.3 | 30.27 | 53.24 | 0.04 |
| December | 4.10 | 3.14 | 1.95 | 2.36 | -5.1 | 20.52 | 40.74 | 0.04 |
| Annual Sum or Average | 9.26 | 7.50 | 5.89 | 2.27 | -0.6 | 70.25 | 132.30 | 0.02 |
| Minimum of Months | 4.10 | 3.14 | 1.95 | 1.05 | -5.1 | 20.52 | 35.00 | 0.00 |
| Maximum of Months | 15.65 | 12.75 | 10.65 | 3.35 | 4.49 | 121.69 | 220.83 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 14.00 | 29-JAN-05:00 | 9.37 | 5.00 | 3.60 | 8.35 | 0.00 | 0.00 |
| February | 11.00 | 07-FEB-14:00 | 9.86 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
| March | 14.00 | 25-MAR-12:00 | 11.22 | 9.00 | 2.60 | 7.35 | 287.00 | 93.00 |
| April | 24.00 | 30-APR-14:00 | 13.13 | 4.00 | 1.50 | 7.75 | 167.50 | 716.00 |
| May | 24.00 | 22-MAY-14:00 | 16.08 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
| June | 27.00 | 13-JUN-16:00 | 17.53 | 12.00 | 3.10 | 12.41 | 141.50 | 652.50 |
| July | 30.00 | 22-JUL-17:00 | 16.80 | 8.00 | 0.00 | 14.28 | 122.00 | 407.00 |
| August | 27.00 | 14-AUG-17:19 | 14.18 | 3.33 | 2.60 | 10.37 | 133.00 | 358.83 |
| September | 23.00 | 11-SEP-16:00 | 16.22 | 12.00 | 2.60 | 8.74 | 108.00 | 325.50 |
| October | 19.00 | 07-OCT-14:00 | 10.10 | 1.00 | 1.50 | 2.22 | 131.00 | 540.50 |
| November | 16.00 | 24-NOV-11:00 | 12.01 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
| December | 13.00 | 23-DEC-10:00 | 7.64 | 2.00 | 7.70 | 6.75 | 70.50 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 11.00 | 7.64 | 1.00 | 0.00 | 2.22 | 0.00 | 0.00 | |
| Maximum of Months | 30.00 | 17.53 | 12.00 | 7.70 | 14.28 | 287.00 | 769.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | -6.0 | 10-JAN-07:00 | -7.0 | -9.0 | 0.00 | -20.0 | 0.00 | 0.00 |
| February | -4.0 | 17-FEB-06:00 | -4.0 | -4.0 | 0.00 | -20.5 | 0.00 | 0.00 |
| March | -1.0 | 08-MAR-06:00 | -1.4 | -2.0 | 0.00 | -14.4 | 17.50 | 184.50 |
| April | 0.00 | 08-APR-04:00 | -0.9 | -2.0 | 0.00 | -12.7 | 0.00 | 0.00 |
| May | 2.00 | 06-MAY-04:00 | 1.57 | 1.00 | 3.60 | -13.7 | 12.50 | 117.00 |
| June | 6.00 | 01-JUN-03:00 | 5.05 | 4.00 | 0.00 | -9.2 | 0.00 | 0.00 |
| July | 7.00 | 05-JUL-04:00 | 6.47 | 6.00 | 3.10 | -7.8 | 28.00 | 155.00 |
| August | 8.00 | 20-AUG-04:00 | 7.45 | 7.00 | 0.00 | -6.6 | 0.00 | 0.00 |
| September | 5.00 | 20-SEP-03:00 | 5.00 | 5.00 | 2.60 | -10.0 | 0.00 | 0.00 |
| October | 2.00 | 07-OCT-03:00 | 2.00 | 2.00 | 0.00 | -13.4 | 0.00 | 0.00 |
| November | -2.0 | 29-NOV-01:00 | -2.0 | -2.0 | 3.10 | -10.7 | 0.00 | 0.00 |
| December | -3.0 | 29-DEC-20:00 | -4.5 | -7.0 | 3.60 | -20.2 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -6.0 | -7.0 | -9.0 | 0.00 | -20.5 | 0.00 | 0.00 | |
| Maximum of Months | 8.00 | 7.45 | 7.00 | 3.60 | -6.6 | 28.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 12.44 | 29-JAN-04:00 | 13.00 | 12.00 | 0.00 | 9.13 | 0.00 | 0.00 |
| February | 9.86 | 07-FEB-14:00 | 11.00 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
| March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
| April | 15.39 | 28-APR-07:00 | 16.00 | 15.00 | 0.00 | 5.54 | 119.50 | 626.00 |
| May | 16.08 | 22-MAY-14:00 | 24.00 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
| June | 19.93 | 25-JUN-17:00 | 22.00 | 19.00 | 0.00 | 15.94 | 136.50 | 360.50 |
| July | 17.31 | 22-JUL-09:00 | 26.00 | 12.00 | 4.60 | 11.46 | 224.50 | 619.50 |
| August | 17.06 | 14-AUG-12:00 | 24.00 | 13.00 | 2.60 | 9.91 | 205.50 | 669.50 |
| September | 16.54 | 10-SEP-15:00 | 21.00 | 14.00 | 3.60 | 8.54 | 160.50 | 483.00 |
| October | 13.58 | 17-OCT-14:00 | 16.00 | 12.00 | 0.00 | 12.03 | 144.00 | 44.50 |
| November | 12.01 | 24-NOV-11:00 | 16.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
| December | 7.93 | 02-DEC-12:00 | 9.00 | 7.00 | 0.00 | 2.01 | 135.50 | 84.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 7.93 | 9.00 | 7.00 | 0.00 | 2.01 | 0.00 | 0.00 | |
| Maximum of Months | 19.93 | 26.00 | 19.00 | 4.60 | 15.94 | 224.50 | 769.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 12.00 | 29-JAN-04:00 | 13.00 | 12.44 | 0.00 | 9.13 | 0.00 | 0.00 |
| February | 9.00 | 07-FEB-14:00 | 11.00 | 9.86 | 2.10 | 6.35 | 138.00 | 225.00 |
| March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
| April | 15.00 | 28-APR-07:00 | 16.00 | 15.39 | 0.00 | 5.54 | 119.50 | 626.00 |
| May | 12.00 | 23-MAY-07:00 | 17.00 | 13.95 | 3.10 | 5.13 | 112.00 | 719.50 |
| June | 19.00 | 25-JUN-17:00 | 22.00 | 19.93 | 0.00 | 15.94 | 136.50 | 360.50 |
| July | 14.00 | 17-JUL-17:00 | 18.00 | 15.45 | 3.60 | 9.91 | 120.00 | 0.00 |
| August | 16.00 | 08-AUG-12:00 | 18.00 | 16.70 | 1.50 | 11.46 | 154.00 | 0.00 |
| September | 14.00 | 10-SEP-15:00 | 21.00 | 16.54 | 3.60 | 8.54 | 160.50 | 483.00 |
| October | 13.00 | 17-OCT-18:00 | 13.00 | 13.00 | 2.60 | 9.33 | 0.00 | 0.00 |
| November | 12.00 | 08-NOV-14:00 | 12.00 | 12.00 | 0.00 | 8.15 | 93.00 | 106.00 |
| December | 7.00 | 02-DEC-11:00 | 8.00 | 7.45 | 3.10 | 1.16 | 144.50 | 146.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 7.00 | 8.00 | 7.45 | 0.00 | 1.16 | 0.00 | 0.00 | |
| Maximum of Months | 19.00 | 22.00 | 19.93 | 3.60 | 15.94 | 160.50 | 719.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 10.33 | 8.85 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 10.00 | 14.79 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 10.33 | 17.09 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 11.26 | 40.86 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 12.54 | 47.73 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 13.82 | 50.98 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 14.77 | 51.67 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 15.12 | 44.67 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 14.78 | 34.25 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 13.84 | 17.71 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 12.55 | 9.34 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 11.27 | 6.14 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.57 | 28.73 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 10.00 | 6.14 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 15.12 | 51.67 | 0.00 |
Report: WaterHeaterReportMonthly
For: G SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124252E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186550814.7 | 59.44 | 0.00 | 0.00 |
| February | 0.112857E+10 | -960101838.3 | 0.00 | 0.00 | 672.00 | 0.00 | -168470016.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124245E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186590934.0 | 59.44 | 0.00 | 0.00 |
| April | 0.117982E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -177266684.0 | 59.44 | 0.00 | 0.00 |
| May | 0.119048E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181993672.9 | 59.44 | 0.00 | 0.00 |
| June | 0.111990E+10 | -949186464.2 | 0.00 | 0.00 | 720.00 | 0.00 | -170711197.4 | 59.44 | 0.00 | 0.00 |
| July | 0.113479E+10 | -960480802.9 | 0.00 | 0.00 | 744.00 | 0.00 | -174314014.9 | 59.44 | 0.00 | 0.00 |
| August | 0.112607E+10 | -952872715.8 | 0.00 | 0.00 | 744.00 | 0.00 | -173197561.1 | 59.44 | 0.00 | 0.00 |
| September | 0.109787E+10 | -929291816.8 | 0.00 | 0.00 | 720.00 | 0.00 | -168576752.1 | 59.44 | 0.00 | 0.00 |
| October | 0.116318E+10 | -980539462.9 | 0.00 | 0.00 | 744.00 | 0.00 | -182638475.5 | 59.44 | 0.00 | 0.00 |
| November | 0.115605E+10 | -975611612.1 | 0.00 | 0.00 | 720.00 | 0.00 | -180434033.2 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186598115.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140040E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213734E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.109787E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186598115.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124252E+10 | -929291816.8 | 0.00 | 0.00 | 744.00 | 0.00 | -168470016.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124247E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186607018.6 | 59.44 | 0.00 | 0.00 |
| April | 0.118213E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179577102.6 | 59.44 | 0.00 | 0.00 |
| May | 0.119290E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184416028.0 | 59.44 | 0.00 | 0.00 |
| June | 0.112172E+10 | -949186072.4 | 0.00 | 0.00 | 720.00 | 0.00 | -172531887.4 | 59.44 | 0.00 | 0.00 |
| July | 0.113575E+10 | -960483130.6 | 0.00 | 0.00 | 744.00 | 0.00 | -175265791.8 | 59.44 | 0.00 | 0.00 |
| August | 0.112746E+10 | -952870723.2 | 0.00 | 0.00 | 744.00 | 0.00 | -174590017.1 | 59.44 | 0.00 | 0.00 |
| September | 0.110202E+10 | -929290810.7 | 0.00 | 0.00 | 720.00 | 0.00 | -172732749.6 | 59.44 | 0.00 | 0.00 |
| October | 0.116646E+10 | -980541170.7 | 0.00 | 0.00 | 744.00 | 0.00 | -185920919.5 | 59.44 | 0.00 | 0.00 |
| November | 0.115620E+10 | -975611673.4 | 0.00 | 0.00 | 720.00 | 0.00 | -180586944.2 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602240.6 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140206E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.215398E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110202E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186607018.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929290810.7 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124247E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186606834.2 | 59.44 | 0.00 | 0.00 |
| April | 0.118197E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179418393.7 | 59.44 | 0.00 | 0.00 |
| May | 0.119289E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184410074.0 | 59.44 | 0.00 | 0.00 |
| June | 0.112183E+10 | -949186902.0 | 0.00 | 0.00 | 720.00 | 0.00 | -172647427.3 | 59.44 | 0.00 | 0.00 |
| July | 0.113542E+10 | -960479699.3 | 0.00 | 0.00 | 744.00 | 0.00 | -174940960.0 | 59.44 | 0.00 | 0.00 |
| August | 0.112709E+10 | -952869934.4 | 0.00 | 0.00 | 744.00 | 0.00 | -174219264.4 | 59.44 | 0.00 | 0.00 |
| September | 0.110121E+10 | -929291086.9 | 0.00 | 0.00 | 720.00 | 0.00 | -171919208.4 | 59.44 | 0.00 | 0.00 |
| October | 0.116640E+10 | -980540721.3 | 0.00 | 0.00 | 744.00 | 0.00 | -185855216.8 | 59.44 | 0.00 | 0.00 |
| November | 0.115620E+10 | -975610064.0 | 0.00 | 0.00 | 720.00 | 0.00 | -180587023.5 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603701.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140190E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.215236E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110121E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186606834.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929291086.9 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.6 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124246E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603995.8 | 59.44 | 0.00 | 0.00 |
| April | 0.118221E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179658914.1 | 59.44 | 0.00 | 0.00 |
| May | 0.119289E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184402409.3 | 59.44 | 0.00 | 0.00 |
| June | 0.112103E+10 | -949187128.2 | 0.00 | 0.00 | 720.00 | 0.00 | -171838699.2 | 59.44 | 0.00 | 0.00 |
| July | 0.113485E+10 | -960482019.9 | 0.00 | 0.00 | 744.00 | 0.00 | -174368110.8 | 59.44 | 0.00 | 0.00 |
| August | 0.112664E+10 | -952872207.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173772144.7 | 59.44 | 0.00 | 0.00 |
| September | 0.110061E+10 | -929291856.2 | 0.00 | 0.00 | 720.00 | 0.00 | -171313559.1 | 59.44 | 0.00 | 0.00 |
| October | 0.116597E+10 | -980540798.2 | 0.00 | 0.00 | 744.00 | 0.00 | -185424730.7 | 59.44 | 0.00 | 0.00 |
| November | 0.115619E+10 | -975610275.9 | 0.00 | 0.00 | 720.00 | 0.00 | -180581130.0 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603711.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140163E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214971E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110061E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186603995.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929291856.2 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.6 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124246E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603987.6 | 59.44 | 0.00 | 0.00 |
| April | 0.118219E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179635853.2 | 59.44 | 0.00 | 0.00 |
| May | 0.119288E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184395180.3 | 59.44 | 0.00 | 0.00 |
| June | 0.112106E+10 | -949187283.5 | 0.00 | 0.00 | 720.00 | 0.00 | -171869291.6 | 59.44 | 0.00 | 0.00 |
| July | 0.113480E+10 | -960481537.3 | 0.00 | 0.00 | 744.00 | 0.00 | -174322828.6 | 59.44 | 0.00 | 0.00 |
| August | 0.112661E+10 | -952871098.0 | 0.00 | 0.00 | 744.00 | 0.00 | -173738109.0 | 59.44 | 0.00 | 0.00 |
| September | 0.110048E+10 | -929295129.0 | 0.00 | 0.00 | 720.00 | 0.00 | -171189464.3 | 59.44 | 0.00 | 0.00 |
| October | 0.116596E+10 | -980541228.3 | 0.00 | 0.00 | 744.00 | 0.00 | -185414617.5 | 59.44 | 0.00 | 0.00 |
| November | 0.115619E+10 | -975611609.7 | 0.00 | 0.00 | 720.00 | 0.00 | -180581686.7 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602231.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140161E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214950E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110048E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186603987.6 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929295129.0 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124239E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186421854.9 | 59.44 | 0.00 | 0.00 |
| February | 0.112848E+10 | -960102961.7 | 0.00 | 0.00 | 672.00 | 0.00 | -168379450.3 | 59.44 | 0.00 | 0.00 |
| March | 0.124242E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186559998.5 | 59.44 | 0.00 | 0.00 |
| April | 0.117891E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176357180.7 | 59.44 | 0.00 | 0.00 |
| May | 0.118934E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180858307.1 | 59.44 | 0.00 | 0.00 |
| June | 0.111882E+10 | -949185134.9 | 0.00 | 0.00 | 720.00 | 0.00 | -169630510.7 | 59.44 | 0.00 | 0.00 |
| July | 0.113392E+10 | -960483941.6 | 0.00 | 0.00 | 744.00 | 0.00 | -173431631.7 | 59.44 | 0.00 | 0.00 |
| August | 0.112557E+10 | -952871956.1 | 0.00 | 0.00 | 744.00 | 0.00 | -172698091.9 | 59.44 | 0.00 | 0.00 |
| September | 0.109688E+10 | -929293155.0 | 0.00 | 0.00 | 720.00 | 0.00 | -167585070.7 | 59.44 | 0.00 | 0.00 |
| October | 0.116152E+10 | -980539939.2 | 0.00 | 0.00 | 744.00 | 0.00 | -180983771.6 | 59.44 | 0.00 | 0.00 |
| November | 0.115580E+10 | -975611908.7 | 0.00 | 0.00 | 720.00 | 0.00 | -180183832.3 | 59.44 | 0.00 | 0.00 |
| December | 0.122222E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186575138.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.139963E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212966E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.109688E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186575138.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124242E+10 | -929293155.0 | 0.00 | 0.00 | 744.00 | 0.00 | -167585070.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: G S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124243E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186463127.3 | 59.44 | 0.00 | 0.00 |
| February | 0.112853E+10 | -960102241.0 | 0.00 | 0.00 | 672.00 | 0.00 | -168425581.7 | 59.44 | 0.00 | 0.00 |
| March | 0.124243E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186567375.5 | 59.44 | 0.00 | 0.00 |
| April | 0.117877E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176210561.5 | 59.44 | 0.00 | 0.00 |
| May | 0.118909E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180612315.8 | 59.44 | 0.00 | 0.00 |
| June | 0.111862E+10 | -949186453.4 | 0.00 | 0.00 | 720.00 | 0.00 | -169429429.9 | 59.44 | 0.00 | 0.00 |
| July | 0.113378E+10 | -960479603.9 | 0.00 | 0.00 | 744.00 | 0.00 | -173298921.3 | 59.44 | 0.00 | 0.00 |
| August | 0.112550E+10 | -952871333.0 | 0.00 | 0.00 | 744.00 | 0.00 | -172630693.4 | 59.44 | 0.00 | 0.00 |
| September | 0.109680E+10 | -929291680.8 | 0.00 | 0.00 | 720.00 | 0.00 | -167506056.9 | 59.44 | 0.00 | 0.00 |
| October | 0.116142E+10 | -980539621.2 | 0.00 | 0.00 | 744.00 | 0.00 | -180883736.6 | 59.44 | 0.00 | 0.00 |
| November | 0.115583E+10 | -975613868.9 | 0.00 | 0.00 | 720.00 | 0.00 | -180220435.0 | 59.44 | 0.00 | 0.00 |
| December | 0.122223E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186581791.2 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.139954E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212883E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.109680E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186581791.2 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124243E+10 | -929291680.8 | 0.00 | 0.00 | 744.00 | 0.00 | -167506056.9 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229771E+10 | -0.211195E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185764422.5 | 59.44 | 0.00 | 0.00 |
| February | 0.208765E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167439573.7 | 59.44 | 0.00 | 0.00 |
| March | 0.229758E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185863453.1 | 59.44 | 0.00 | 0.00 |
| April | 0.217630E+10 | -0.200512E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -171184020.8 | 59.44 | 0.00 | 0.00 |
| May | 0.219299E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176022492.5 | 59.44 | 0.00 | 0.00 |
| June | 0.206593E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167555125.1 | 59.44 | 0.00 | 0.00 |
| July | 0.209384E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172863262.7 | 59.44 | 0.00 | 0.00 |
| August | 0.207835E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172598101.8 | 59.44 | 0.00 | 0.00 |
| September | 0.202623E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167638037.2 | 59.44 | 0.00 | 0.00 |
| October | 0.214132E+10 | -0.196109E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180230569.0 | 59.44 | 0.00 | 0.00 |
| November | 0.213089E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179661744.5 | 59.44 | 0.00 | 0.00 |
| December | 0.225777E+10 | -0.207131E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186468631.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258466E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211329E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202623E+10 | -0.211195E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186468631.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229771E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167439573.7 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229854E+10 | -0.211195E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186598701.2 | 59.44 | 0.00 | 0.00 |
| February | 0.208874E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168530500.2 | 59.44 | 0.00 | 0.00 |
| March | 0.229814E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186414309.2 | 59.44 | 0.00 | 0.00 |
| April | 0.218005E+10 | -0.200511E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174931841.5 | 59.44 | 0.00 | 0.00 |
| May | 0.219488E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177907247.4 | 59.44 | 0.00 | 0.00 |
| June | 0.206612E+10 | -0.189837E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167747916.6 | 59.44 | 0.00 | 0.00 |
| July | 0.209393E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172964582.1 | 59.44 | 0.00 | 0.00 |
| August | 0.207857E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172821186.3 | 59.44 | 0.00 | 0.00 |
| September | 0.202750E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168912207.4 | 59.44 | 0.00 | 0.00 |
| October | 0.214487E+10 | -0.196109E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183785730.5 | 59.44 | 0.00 | 0.00 |
| November | 0.213177E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180538836.4 | 59.44 | 0.00 | 0.00 |
| December | 0.225791E+10 | -0.207131E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604840.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258610E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212776E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202750E+10 | -0.211195E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186604840.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229854E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167747916.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229769E+10 | -0.211195E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185741318.9 | 59.44 | 0.00 | 0.00 |
| February | 0.208774E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -167535437.4 | 59.44 | 0.00 | 0.00 |
| March | 0.229756E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185839126.7 | 59.44 | 0.00 | 0.00 |
| April | 0.217574E+10 | -0.200512E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -170627940.2 | 59.44 | 0.00 | 0.00 |
| May | 0.219266E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -175689036.5 | 59.44 | 0.00 | 0.00 |
| June | 0.206597E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167587357.7 | 59.44 | 0.00 | 0.00 |
| July | 0.209381E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172839191.5 | 59.44 | 0.00 | 0.00 |
| August | 0.207836E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172609959.9 | 59.44 | 0.00 | 0.00 |
| September | 0.202614E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167549355.1 | 59.44 | 0.00 | 0.00 |
| October | 0.214119E+10 | -0.196109E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180097003.2 | 59.44 | 0.00 | 0.00 |
| November | 0.213089E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -179666736.8 | 59.44 | 0.00 | 0.00 |
| December | 0.225774E+10 | -0.207130E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186439922.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258455E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.211222E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202614E+10 | -0.211195E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186439922.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229769E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167535437.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229855E+10 | -0.211195E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186604396.0 | 59.44 | 0.00 | 0.00 |
| February | 0.208875E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168544506.1 | 59.44 | 0.00 | 0.00 |
| March | 0.229817E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186447937.0 | 59.44 | 0.00 | 0.00 |
| April | 0.217931E+10 | -0.200512E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174189577.6 | 59.44 | 0.00 | 0.00 |
| May | 0.219436E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177391430.8 | 59.44 | 0.00 | 0.00 |
| June | 0.206616E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167779481.3 | 59.44 | 0.00 | 0.00 |
| July | 0.209391E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172938497.3 | 59.44 | 0.00 | 0.00 |
| August | 0.207856E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172812837.1 | 59.44 | 0.00 | 0.00 |
| September | 0.202702E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -168429856.7 | 59.44 | 0.00 | 0.00 |
| October | 0.214470E+10 | -0.196108E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -183611044.5 | 59.44 | 0.00 | 0.00 |
| November | 0.213178E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180551056.3 | 59.44 | 0.00 | 0.00 |
| December | 0.225791E+10 | -0.207130E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605132.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258592E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212591E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202702E+10 | -0.211195E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605132.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229855E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167779481.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229848E+10 | -0.211195E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186529380.6 | 59.44 | 0.00 | 0.00 |
| February | 0.208873E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168525395.3 | 59.44 | 0.00 | 0.00 |
| March | 0.229785E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186130953.3 | 59.44 | 0.00 | 0.00 |
| April | 0.217921E+10 | -0.200512E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174089660.4 | 59.44 | 0.00 | 0.00 |
| May | 0.219351E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176540441.7 | 59.44 | 0.00 | 0.00 |
| June | 0.206569E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167314978.2 | 59.44 | 0.00 | 0.00 |
| July | 0.209363E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172663726.8 | 59.44 | 0.00 | 0.00 |
| August | 0.207834E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172591286.5 | 59.44 | 0.00 | 0.00 |
| September | 0.202652E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167931907.2 | 59.44 | 0.00 | 0.00 |
| October | 0.214317E+10 | -0.196108E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182085604.0 | 59.44 | 0.00 | 0.00 |
| November | 0.213157E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180342379.0 | 59.44 | 0.00 | 0.00 |
| December | 0.225791E+10 | -0.207131E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601646.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258546E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212135E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202652E+10 | -0.211195E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186601646.9 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229848E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167314978.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229848E+10 | -0.211195E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186530007.2 | 59.44 | 0.00 | 0.00 |
| February | 0.208873E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -168525584.0 | 59.44 | 0.00 | 0.00 |
| March | 0.229785E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186131477.4 | 59.44 | 0.00 | 0.00 |
| April | 0.217910E+10 | -0.200512E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -173983128.0 | 59.44 | 0.00 | 0.00 |
| May | 0.219343E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -176462113.0 | 59.44 | 0.00 | 0.00 |
| June | 0.206569E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167317828.2 | 59.44 | 0.00 | 0.00 |
| July | 0.209364E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172661907.5 | 59.44 | 0.00 | 0.00 |
| August | 0.207834E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172590041.9 | 59.44 | 0.00 | 0.00 |
| September | 0.202648E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167886568.0 | 59.44 | 0.00 | 0.00 |
| October | 0.214314E+10 | -0.196109E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182051135.3 | 59.44 | 0.00 | 0.00 |
| November | 0.213158E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -180343398.6 | 59.44 | 0.00 | 0.00 |
| December | 0.225791E+10 | -0.207130E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186605587.5 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258544E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.212109E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202648E+10 | -0.211195E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186605587.5 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229848E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -167317828.2 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229655E+10 | -0.211194E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184611057.6 | 59.44 | 0.00 | 0.00 |
| February | 0.208674E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166532888.6 | 59.44 | 0.00 | 0.00 |
| March | 0.229673E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185010375.4 | 59.44 | 0.00 | 0.00 |
| April | 0.217479E+10 | -0.200512E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169673321.9 | 59.44 | 0.00 | 0.00 |
| May | 0.219151E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174537527.3 | 59.44 | 0.00 | 0.00 |
| June | 0.206556E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167177843.5 | 59.44 | 0.00 | 0.00 |
| July | 0.209358E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172612065.3 | 59.44 | 0.00 | 0.00 |
| August | 0.207825E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172501797.3 | 59.44 | 0.00 | 0.00 |
| September | 0.202574E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167145194.7 | 59.44 | 0.00 | 0.00 |
| October | 0.213874E+10 | -0.196109E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177650932.7 | 59.44 | 0.00 | 0.00 |
| November | 0.212926E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178036994.9 | 59.44 | 0.00 | 0.00 |
| December | 0.225747E+10 | -0.207130E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186165059.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258349E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210166E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202574E+10 | -0.211194E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186165059.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229673E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166532888.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: M S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.229655E+10 | -0.211194E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -184606730.7 | 59.44 | 0.00 | 0.00 |
| February | 0.208676E+10 | -0.192021E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -166544005.5 | 59.44 | 0.00 | 0.00 |
| March | 0.229673E+10 | -0.211172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185007915.0 | 59.44 | 0.00 | 0.00 |
| April | 0.217474E+10 | -0.200511E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -169620182.5 | 59.44 | 0.00 | 0.00 |
| May | 0.219148E+10 | -0.201697E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -174510042.5 | 59.44 | 0.00 | 0.00 |
| June | 0.206556E+10 | -0.189838E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167182740.9 | 59.44 | 0.00 | 0.00 |
| July | 0.209358E+10 | -0.192097E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172610458.6 | 59.44 | 0.00 | 0.00 |
| August | 0.207825E+10 | -0.190575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -172502210.6 | 59.44 | 0.00 | 0.00 |
| September | 0.202573E+10 | -0.185859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -167141080.8 | 59.44 | 0.00 | 0.00 |
| October | 0.213872E+10 | -0.196109E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -177636347.0 | 59.44 | 0.00 | 0.00 |
| November | 0.212927E+10 | -0.195123E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -178037618.5 | 59.44 | 0.00 | 0.00 |
| December | 0.225746E+10 | -0.207130E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186160529.8 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.258348E+11 | -0.237333E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.210156E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.202573E+10 | -0.211194E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186160529.8 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.229673E+10 | -0.185859E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -166544005.5 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124193E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185959778.0 | 59.44 | 0.00 | 0.00 |
| February | 0.112762E+10 | -960100940.2 | 0.00 | 0.00 | 672.00 | 0.00 | -167523886.4 | 59.44 | 0.00 | 0.00 |
| March | 0.124193E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186071869.1 | 59.44 | 0.00 | 0.00 |
| April | 0.117732E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174764823.2 | 59.44 | 0.00 | 0.00 |
| May | 0.118939E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180902854.2 | 59.44 | 0.00 | 0.00 |
| June | 0.112079E+10 | -949185413.5 | 0.00 | 0.00 | 720.00 | 0.00 | -171604553.8 | 59.44 | 0.00 | 0.00 |
| July | 0.113639E+10 | -960482265.5 | 0.00 | 0.00 | 744.00 | 0.00 | -175911657.3 | 59.44 | 0.00 | 0.00 |
| August | 0.112856E+10 | -952872744.5 | 0.00 | 0.00 | 744.00 | 0.00 | -175690456.6 | 59.44 | 0.00 | 0.00 |
| September | 0.110142E+10 | -929291222.5 | 0.00 | 0.00 | 720.00 | 0.00 | -172124438.8 | 59.44 | 0.00 | 0.00 |
| October | 0.116421E+10 | -980541245.6 | 0.00 | 0.00 | 744.00 | 0.00 | -183669035.4 | 59.44 | 0.00 | 0.00 |
| November | 0.115550E+10 | -975612528.0 | 0.00 | 0.00 | 720.00 | 0.00 | -179892408.1 | 59.44 | 0.00 | 0.00 |
| December | 0.122210E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186450368.4 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140072E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214057E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110142E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186450368.4 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124193E+10 | -929291222.5 | 0.00 | 0.00 | 744.00 | 0.00 | -167523886.4 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NW APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186602956.5 | 59.44 | 0.00 | 0.00 |
| February | 0.112863E+10 | -960099813.5 | 0.00 | 0.00 | 672.00 | 0.00 | -168527321.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124237E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186513907.8 | 59.44 | 0.00 | 0.00 |
| April | 0.117947E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176911756.8 | 59.44 | 0.00 | 0.00 |
| May | 0.119064E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -182160350.2 | 59.44 | 0.00 | 0.00 |
| June | 0.112118E+10 | -949185982.3 | 0.00 | 0.00 | 720.00 | 0.00 | -171992158.8 | 59.44 | 0.00 | 0.00 |
| July | 0.113678E+10 | -960481749.3 | 0.00 | 0.00 | 744.00 | 0.00 | -176299079.2 | 59.44 | 0.00 | 0.00 |
| August | 0.112937E+10 | -952871505.3 | 0.00 | 0.00 | 744.00 | 0.00 | -176500028.5 | 59.44 | 0.00 | 0.00 |
| September | 0.110373E+10 | -929291753.9 | 0.00 | 0.00 | 720.00 | 0.00 | -174438661.4 | 59.44 | 0.00 | 0.00 |
| October | 0.116622E+10 | -980541409.2 | 0.00 | 0.00 | 744.00 | 0.00 | -185679532.5 | 59.44 | 0.00 | 0.00 |
| November | 0.115619E+10 | -975611092.3 | 0.00 | 0.00 | 720.00 | 0.00 | -180577966.0 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603761.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140194E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.215281E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110373E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186603761.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929291753.9 | 0.00 | 0.00 | 744.00 | 0.00 | -168527321.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T SE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124190E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185928904.5 | 59.44 | 0.00 | 0.00 |
| February | 0.112775E+10 | -960101007.9 | 0.00 | 0.00 | 672.00 | 0.00 | -167651015.6 | 59.44 | 0.00 | 0.00 |
| March | 0.124195E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186089354.2 | 59.44 | 0.00 | 0.00 |
| April | 0.117674E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174180155.5 | 59.44 | 0.00 | 0.00 |
| May | 0.118897E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180483873.3 | 59.44 | 0.00 | 0.00 |
| June | 0.112058E+10 | -949185851.1 | 0.00 | 0.00 | 720.00 | 0.00 | -171393630.9 | 59.44 | 0.00 | 0.00 |
| July | 0.113612E+10 | -960483683.2 | 0.00 | 0.00 | 744.00 | 0.00 | -175640430.5 | 59.44 | 0.00 | 0.00 |
| August | 0.112831E+10 | -952873251.3 | 0.00 | 0.00 | 744.00 | 0.00 | -175436972.4 | 59.44 | 0.00 | 0.00 |
| September | 0.110105E+10 | -929290885.1 | 0.00 | 0.00 | 720.00 | 0.00 | -171757608.4 | 59.44 | 0.00 | 0.00 |
| October | 0.116406E+10 | -980541948.8 | 0.00 | 0.00 | 744.00 | 0.00 | -183520769.4 | 59.44 | 0.00 | 0.00 |
| November | 0.115552E+10 | -975612362.5 | 0.00 | 0.00 | 720.00 | 0.00 | -179908614.2 | 59.44 | 0.00 | 0.00 |
| December | 0.122207E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186426250.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140050E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213842E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110105E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186426250.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124195E+10 | -929290885.1 | 0.00 | 0.00 | 744.00 | 0.00 | -167651015.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T NE APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124238E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186523729.4 | 59.44 | 0.00 | 0.00 |
| April | 0.117881E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176250052.5 | 59.44 | 0.00 | 0.00 |
| May | 0.119009E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181600822.0 | 59.44 | 0.00 | 0.00 |
| June | 0.112082E+10 | -949186604.8 | 0.00 | 0.00 | 720.00 | 0.00 | -171633687.8 | 59.44 | 0.00 | 0.00 |
| July | 0.113634E+10 | -960482694.8 | 0.00 | 0.00 | 744.00 | 0.00 | -175857444.2 | 59.44 | 0.00 | 0.00 |
| August | 0.112891E+10 | -952872121.1 | 0.00 | 0.00 | 744.00 | 0.00 | -176040105.2 | 59.44 | 0.00 | 0.00 |
| September | 0.110287E+10 | -929292016.7 | 0.00 | 0.00 | 720.00 | 0.00 | -173575574.0 | 59.44 | 0.00 | 0.00 |
| October | 0.116618E+10 | -980540719.6 | 0.00 | 0.00 | 744.00 | 0.00 | -185639263.7 | 59.44 | 0.00 | 0.00 |
| November | 0.115620E+10 | -975611535.8 | 0.00 | 0.00 | 720.00 | 0.00 | -180586143.6 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603015.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140161E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214946E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110287E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929292016.7 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.3 | 59.44 | 0.00 | 0.00 |
| March | 0.124237E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186505359.2 | 59.44 | 0.00 | 0.00 |
| April | 0.117947E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176915593.6 | 59.44 | 0.00 | 0.00 |
| May | 0.119038E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181896369.9 | 59.44 | 0.00 | 0.00 |
| June | 0.112012E+10 | -949185938.3 | 0.00 | 0.00 | 720.00 | 0.00 | -170930974.1 | 59.44 | 0.00 | 0.00 |
| July | 0.113578E+10 | -960483398.5 | 0.00 | 0.00 | 744.00 | 0.00 | -175300251.2 | 59.44 | 0.00 | 0.00 |
| August | 0.112831E+10 | -952871330.6 | 0.00 | 0.00 | 744.00 | 0.00 | -175442560.1 | 59.44 | 0.00 | 0.00 |
| September | 0.110303E+10 | -929292518.6 | 0.00 | 0.00 | 720.00 | 0.00 | -173738972.3 | 59.44 | 0.00 | 0.00 |
| October | 0.116627E+10 | -980540874.6 | 0.00 | 0.00 | 744.00 | 0.00 | -185729682.7 | 59.44 | 0.00 | 0.00 |
| November | 0.115619E+10 | -975610295.3 | 0.00 | 0.00 | 720.00 | 0.00 | -180581076.5 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603870.3 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140154E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214879E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110303E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186603870.3 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929292518.6 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.3 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T N2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124257E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| February | 0.112864E+10 | -960099899.2 | 0.00 | 0.00 | 672.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
| March | 0.124236E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186503329.1 | 59.44 | 0.00 | 0.00 |
| April | 0.117939E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -176829820.2 | 59.44 | 0.00 | 0.00 |
| May | 0.119031E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -181827640.9 | 59.44 | 0.00 | 0.00 |
| June | 0.112009E+10 | -949186664.1 | 0.00 | 0.00 | 720.00 | 0.00 | -170907930.2 | 59.44 | 0.00 | 0.00 |
| July | 0.113575E+10 | -960482254.4 | 0.00 | 0.00 | 744.00 | 0.00 | -175266603.7 | 59.44 | 0.00 | 0.00 |
| August | 0.112829E+10 | -952871920.6 | 0.00 | 0.00 | 744.00 | 0.00 | -175413909.9 | 59.44 | 0.00 | 0.00 |
| September | 0.110294E+10 | -929293859.4 | 0.00 | 0.00 | 720.00 | 0.00 | -173646041.9 | 59.44 | 0.00 | 0.00 |
| October | 0.116625E+10 | -980541452.9 | 0.00 | 0.00 | 744.00 | 0.00 | -185711074.3 | 59.44 | 0.00 | 0.00 |
| November | 0.115620E+10 | -975612680.3 | 0.00 | 0.00 | 720.00 | 0.00 | -180582806.0 | 59.44 | 0.00 | 0.00 |
| December | 0.122225E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186601049.9 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.140150E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.214844E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110294E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186603548.7 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124257E+10 | -929293859.4 | 0.00 | 0.00 | 744.00 | 0.00 | -168543362.0 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S1 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124164E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185670938.2 | 59.44 | 0.00 | 0.00 |
| February | 0.112742E+10 | -960102671.4 | 0.00 | 0.00 | 672.00 | 0.00 | -167321391.6 | 59.44 | 0.00 | 0.00 |
| March | 0.124175E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185893013.9 | 59.44 | 0.00 | 0.00 |
| April | 0.117664E+10 | -0.100255E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174085879.6 | 59.44 | 0.00 | 0.00 |
| May | 0.118869E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180203265.6 | 59.44 | 0.00 | 0.00 |
| June | 0.111970E+10 | -949185779.2 | 0.00 | 0.00 | 720.00 | 0.00 | -170516217.2 | 59.44 | 0.00 | 0.00 |
| July | 0.113541E+10 | -960479950.5 | 0.00 | 0.00 | 744.00 | 0.00 | -174932375.0 | 59.44 | 0.00 | 0.00 |
| August | 0.112752E+10 | -952872393.9 | 0.00 | 0.00 | 744.00 | 0.00 | -174644334.0 | 59.44 | 0.00 | 0.00 |
| September | 0.110019E+10 | -929291439.0 | 0.00 | 0.00 | 720.00 | 0.00 | -170900764.2 | 59.44 | 0.00 | 0.00 |
| October | 0.116354E+10 | -980540464.0 | 0.00 | 0.00 | 744.00 | 0.00 | -183003486.1 | 59.44 | 0.00 | 0.00 |
| November | 0.115521E+10 | -975611073.3 | 0.00 | 0.00 | 720.00 | 0.00 | -179603847.5 | 59.44 | 0.00 | 0.00 |
| December | 0.122197E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186319012.0 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.139997E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213309E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110019E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186319012.0 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124175E+10 | -929291439.0 | 0.00 | 0.00 | 744.00 | 0.00 | -167321391.6 | 59.44 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: T S2 APARTMENT WATER HEATER
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.124164E+10 | -0.105597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185663876.0 | 59.44 | 0.00 | 0.00 |
| February | 0.112743E+10 | -960102832.5 | 0.00 | 0.00 | 672.00 | 0.00 | -167326745.3 | 59.44 | 0.00 | 0.00 |
| March | 0.124174E+10 | -0.105586E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -185888286.0 | 59.44 | 0.00 | 0.00 |
| April | 0.117659E+10 | -0.100256E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -174037353.6 | 59.44 | 0.00 | 0.00 |
| May | 0.118866E+10 | -0.100848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -180173421.6 | 59.44 | 0.00 | 0.00 |
| June | 0.111971E+10 | -949186244.2 | 0.00 | 0.00 | 720.00 | 0.00 | -170521125.6 | 59.44 | 0.00 | 0.00 |
| July | 0.113540E+10 | -960481452.0 | 0.00 | 0.00 | 744.00 | 0.00 | -174920987.1 | 59.44 | 0.00 | 0.00 |
| August | 0.112752E+10 | -952871166.9 | 0.00 | 0.00 | 744.00 | 0.00 | -174643944.1 | 59.44 | 0.00 | 0.00 |
| September | 0.110018E+10 | -929291343.1 | 0.00 | 0.00 | 720.00 | 0.00 | -170887893.5 | 59.44 | 0.00 | 0.00 |
| October | 0.116354E+10 | -980540356.2 | 0.00 | 0.00 | 744.00 | 0.00 | -182996139.0 | 59.44 | 0.00 | 0.00 |
| November | 0.115521E+10 | -975611905.0 | 0.00 | 0.00 | 720.00 | 0.00 | -179598600.4 | 59.44 | 0.00 | 0.00 |
| December | 0.122196E+10 | -0.103565E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -186315427.1 | 59.44 | 0.00 | 0.00 |
| Annual Sum or Average | 0.139996E+11 | -0.118666E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213297E+10 | 59.44 | 0.00 | 0.00 |
| Minimum of Months | 0.110018E+10 | -0.105597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -186315427.1 | 59.44 | 0.00 | 0.00 |
| Maximum of Months | 0.124174E+10 | -929291343.1 | 0.00 | 0.00 | 744.00 | 0.00 | -167326745.3 | 59.44 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 195.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 217.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 215.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 359.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 417.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 410.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 429.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 396.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 337.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 234.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 171.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 3515.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 429.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.168483E+10 | 1495.61 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.144515E+10 | 1363.42 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.156636E+10 | 1120.02 | 16-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.354576E+09 | 825.14 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.208078E+09 | 749.69 | 18-MAY-21:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 1964461.02 | 187.18 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.330739E+09 | 709.58 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.104680E+10 | 1130.76 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.207641E+10 | 1420.17 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.871491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.207641E+10 | 1495.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.230587E+10 | 1693.67 | 10-JAN-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.203333E+10 | 1467.74 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.184521E+10 | 1160.60 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.733919E+09 | 908.82 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.405216E+09 | 1059.32 | 21-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 10912117.21 | 369.23 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.648786E+09 | 982.37 | 24-OCT-16:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.151145E+10 | 1355.14 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.247052E+10 | 1550.69 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119652E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.247052E+10 | 1693.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.479428E+09 | 9512.42 | 03-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.308230E+09 | 9512.42 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.355792E+09 | 9512.42 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 5343180.16 | 9512.42 | 03-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 2144610.19 | 5614.36 | 23-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.124676E+09 | 9512.42 | 17-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.519060E+09 | 9512.42 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.179467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.519060E+09 | 9512.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.230028E+10 | 1702.52 | 12-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.206597E+10 | 1525.30 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.184241E+10 | 1197.75 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.669579E+09 | 924.64 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.374388E+09 | 809.65 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 17181662.04 | 444.73 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.633504E+09 | 1197.14 | 24-OCT-16:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.150806E+10 | 1336.98 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.243554E+10 | 1564.87 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.118469E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.243554E+10 | 1702.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.157503E+10 | 1261.69 | 12-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.141460E+10 | 1077.82 | 18-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.120598E+10 | 805.77 | 08-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.466068E+09 | 636.09 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.199259E+09 | 562.49 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 816638.10 | 119.43 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.313811E+09 | 498.45 | 23-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.943210E+09 | 955.84 | 29-NOV-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.164479E+10 | 1104.87 | 30-DEC-02:70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.776355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.164479E+10 | 1261.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.157471E+10 | 1262.18 | 12-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.141622E+10 | 1079.82 | 18-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.120607E+10 | 805.66 | 08-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.462359E+09 | 636.52 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.196882E+09 | 562.45 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 965660.93 | 127.60 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.312917E+09 | 498.40 | 23-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.943108E+09 | 954.42 | 29-NOV-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.164307E+10 | 1105.05 | 30-DEC-02:70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.775630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.164307E+10 | 1262.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.989831E+09 | 1027.27 | 10-JAN-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.863459E+09 | 962.03 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.946282E+09 | 764.66 | 16-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.151232E+09 | 555.30 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 59821165.34 | 361.83 | 18-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 98757718.58 | 435.99 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.511379E+09 | 742.63 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.127551E+10 | 975.22 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.489627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.127551E+10 | 1027.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.112126E+10 | 1125.40 | 10-JAN-08:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.968672E+09 | 1029.83 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.104705E+10 | 825.45 | 16-MAR-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.161885E+09 | 587.51 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 52020384.27 | 350.93 | 18-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 99156240.71 | 439.18 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.565784E+09 | 790.80 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.142109E+10 | 1048.99 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.543692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.142109E+10 | 1125.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.171437E+10 | 2544.67 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.130376E+10 | 2154.38 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.116605E+10 | 1606.97 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 24643556.37 | 882.35 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 1693764.84 | 242.21 | 05-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.161067E+09 | 1114.19 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.115165E+10 | 2075.61 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.293220E+10 | 2517.65 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.845543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.293220E+10 | 2544.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.285490E+10 | 2847.13 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.236896E+10 | 2349.88 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.164572E+10 | 1688.77 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.158099E+09 | 1094.36 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 12647313.41 | 714.61 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.490261E+09 | 1161.60 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.205730E+10 | 2472.52 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.369349E+10 | 2768.85 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.132814E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.369349E+10 | 2847.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.170445E+10 | 2571.81 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.135009E+10 | 2274.72 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.116270E+10 | 1661.62 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 24367881.19 | 931.09 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 2232537.86 | 331.28 | 05-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.154717E+09 | 1121.93 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.114211E+10 | 2038.26 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.286520E+10 | 2549.33 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.840587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.286520E+10 | 2571.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.284320E+10 | 2878.39 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.243354E+10 | 2481.50 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.162860E+10 | 1765.42 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.135641E+09 | 1134.00 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 12759819.93 | 698.44 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.468341E+09 | 1171.02 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.204807E+10 | 2434.78 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.362200E+10 | 2808.53 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.131921E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.362200E+10 | 2878.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.164668E+10 | 1916.89 | 12-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.140007E+10 | 1623.82 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.777747E+09 | 1083.92 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 33162629.71 | 658.30 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 89454333.84 | 570.80 | 23-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.975674E+09 | 1607.35 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.213854E+10 | 1831.67 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.706132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.213854E+10 | 1916.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.164595E+10 | 1918.25 | 12-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.140386E+10 | 1630.47 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.778572E+09 | 1088.54 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 32177077.59 | 661.08 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 88778202.97 | 574.31 | 23-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.975438E+09 | 1606.47 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.213494E+10 | 1832.89 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.705972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.213494E+10 | 1918.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.663058E+09 | 1682.69 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.452828E+09 | 1454.39 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.380390E+09 | 983.92 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 5012376.65 | 349.14 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 1865436.37 | 264.65 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.289282E+09 | 1167.74 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.140966E+10 | 1646.68 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.320209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.140966E+10 | 1682.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.662233E+09 | 1683.45 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.455744E+09 | 1464.16 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.381168E+09 | 990.01 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 5045229.39 | 350.75 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 1939062.59 | 265.80 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.288801E+09 | 1162.47 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.140565E+10 | 1647.93 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.320058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.140565E+10 | 1683.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.220735E+10 | 2324.09 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.180977E+10 | 2055.18 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.165713E+10 | 1592.73 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.500637E+09 | 1159.93 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.451318E+09 | 1349.31 | 05-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 50941655.50 | 1314.06 | 02-JUN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 24992081.32 | 1062.81 | 02-JUL-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 1565277.14 | 245.99 | 24-AUG-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 96039739.55 | 729.80 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.915647E+09 | 1221.96 | 19-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.178435E+10 | 1992.86 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.292970E+10 | 2235.49 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.124294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 1565277.14 | 245.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.292970E+10 | 2324.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.279966E+10 | 2391.69 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.235807E+10 | 2140.83 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.190500E+10 | 1615.03 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.697288E+09 | 1292.52 | 09-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.533462E+09 | 1353.39 | 05-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 54416323.61 | 927.70 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 28545316.10 | 1321.58 | 02-JUL-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4649440.10 | 406.38 | 24-AUG-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.193243E+09 | 876.47 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.124895E+10 | 1303.64 | 23-OCT-06:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.223533E+10 | 2097.54 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.334392E+10 | 2317.78 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.154025E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 4649440.10 | 406.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.334392E+10 | 2391.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.220526E+10 | 2339.51 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.182515E+10 | 2119.36 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.164680E+10 | 1619.51 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.462832E+09 | 1192.56 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.427179E+09 | 1356.92 | 05-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 51851395.94 | 963.44 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 20330760.14 | 1056.58 | 02-JUL-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 1670090.92 | 211.01 | 23-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 83067357.58 | 734.36 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.902781E+09 | 1223.05 | 19-OCT-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.177772E+10 | 1975.90 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.289401E+10 | 2251.34 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.122986E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 1670090.92 | 211.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.289401E+10 | 2339.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.279511E+10 | 2406.69 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.239454E+10 | 2192.71 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.189553E+10 | 1641.21 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.641256E+09 | 1295.96 | 08-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.508164E+09 | 1363.13 | 05-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 58986442.23 | 984.18 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 23028938.70 | 1187.19 | 02-JUL-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4987280.52 | 370.43 | 23-AUG-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.166093E+09 | 870.66 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.122568E+10 | 1316.09 | 23-OCT-06:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.222947E+10 | 2088.26 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.330446E+10 | 2333.65 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.152473E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 4987280.52 | 370.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.330446E+10 | 2406.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.204915E+10 | 1792.02 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.174366E+10 | 1629.90 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134091E+10 | 1175.70 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.446024E+09 | 955.36 | 08-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.283563E+09 | 944.01 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 17401248.36 | 613.64 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 1415226.08 | 199.15 | 05-JUL-04:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 65825785.72 | 551.69 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.789816E+09 | 930.80 | 23-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.154419E+10 | 1540.90 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.237905E+10 | 1712.38 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106610E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.237905E+10 | 1792.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.204917E+10 | 1792.76 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.174635E+10 | 1634.23 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.134094E+10 | 1178.01 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.443709E+09 | 959.50 | 08-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.283360E+09 | 946.03 | 06-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 17910770.21 | 621.73 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 1240157.31 | 187.83 | 05-JUL-04:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 63803614.74 | 548.89 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.789566E+09 | 931.09 | 23-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.154436E+10 | 1539.39 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.237726E+10 | 1714.78 | 30-DEC-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106577E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.237726E+10 | 1792.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.147955E+10 | 1717.82 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.120284E+10 | 1543.70 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.110336E+10 | 1151.22 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.264508E+09 | 850.35 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.212265E+09 | 909.65 | 05-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 15586952.83 | 580.55 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 1182927.30 | 175.31 | 05-JUL-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 14473536.55 | 358.21 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.491220E+09 | 817.36 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111727E+10 | 1414.73 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.197979E+10 | 1642.78 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.788205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.197979E+10 | 1717.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.147990E+10 | 1718.66 | 10-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.120595E+10 | 1549.97 | 17-FEB-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.110378E+10 | 1153.83 | 04-MAR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.263191E+09 | 853.71 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.212486E+09 | 910.51 | 05-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 16080069.81 | 588.02 | 08-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 1091512.13 | 167.73 | 05-JUL-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 14078905.97 | 358.93 | 20-SEP-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.491460E+09 | 817.05 | 28-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.111783E+10 | 1412.52 | 29-NOV-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.197802E+10 | 1643.98 | 30-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.788386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.197802E+10 | 1718.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 65076793.14 | 65076793.14 | 1475.64 | 30-APR-16:10 | 1475.64 | 0.00 |
| May | 0.00 | 0.00 | 42632282.06 | 40783130.77 | 779.78 | 22-MAY-16:10 | 752.00 | 0.00 |
| June | 0.00 | 0.00 | 0.279356E+09 | 0.258187E+09 | 1797.71 | 13-JUN-17:00 | 1694.75 | 0.00 |
| July | 0.00 | 0.00 | 0.762467E+09 | 0.703811E+09 | 2226.64 | 22-JUL-17:30 | 2226.64 | 0.00 |
| August | 0.00 | 0.00 | 0.853427E+09 | 0.793093E+09 | 1959.43 | 14-AUG-16:03 | 1930.83 | 0.00 |
| September | 0.00 | 0.00 | 0.639723E+09 | 0.605670E+09 | 1887.86 | 13-SEP-16:03 | 1785.89 | 0.00 |
| October | 0.00 | 0.00 | 63561559.57 | 63561559.57 | 745.46 | 03-OCT-16:04 | 745.46 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.270624E+10 | 0.253018E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.853427E+09 | 0.793093E+09 | 2226.64 | 2226.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 7167460.98 | 7167460.98 | 545.14 | 30-APR-17:40 | 545.14 | 0.00 |
| May | 0.00 | 0.00 | 1017409.88 | 964662.95 | 162.37 | 22-MAY-16:05 | 153.04 | 0.00 |
| June | 0.00 | 0.00 | 0.123480E+09 | 0.111379E+09 | 1386.35 | 13-JUN-17:10 | 1272.36 | 0.00 |
| July | 0.00 | 0.00 | 0.383914E+09 | 0.351959E+09 | 1837.78 | 22-JUL-18:00 | 1837.78 | 0.00 |
| August | 0.00 | 0.00 | 0.221668E+09 | 0.202974E+09 | 1271.37 | 14-AUG-16:50 | 1243.34 | 0.00 |
| September | 0.00 | 0.00 | 39583713.95 | 36101251.62 | 865.36 | 13-SEP-16:30 | 789.64 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.776830E+09 | 0.710545E+09 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.383914E+09 | 0.351959E+09 | 1837.78 | 1837.78 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 93525698.73 | 93523944.24 | 1409.28 | 28-APR-14:40 | 1409.28 | 0.00 |
| May | 0.00 | 0.00 | 0.194061E+09 | 0.183995E+09 | 3239.87 | 23-MAY-08:63 | 3023.00 | 0.00 |
| June | 0.00 | 0.00 | 0.585531E+09 | 0.534927E+09 | 6403.33 | 27-JUN-08:62 | 4950.49 | 0.00 |
| July | 0.00 | 0.00 | 0.938942E+09 | 0.853706E+09 | 6335.04 | 18-JUL-08:62 | 5312.67 | 0.00 |
| August | 0.00 | 0.00 | 0.123940E+10 | 0.114208E+10 | 6348.46 | 17-AUG-08:62 | 5215.22 | 0.00 |
| September | 0.00 | 0.00 | 0.934986E+09 | 0.886049E+09 | 6283.38 | 01-SEP-08:62 | 5398.90 | 0.00 |
| October | 0.00 | 0.00 | 0.156332E+09 | 0.155373E+09 | 1258.50 | 03-OCT-14:30 | 1258.50 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.414278E+10 | 0.384965E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.123940E+10 | 0.114208E+10 | 6403.33 | 5398.90 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 4554829.57 | 4554829.57 | 325.35 | 30-APR-18:00 | 325.35 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.105752E+09 | 95537461.98 | 983.42 | 13-JUN-17:00 | 893.42 | 0.00 |
| July | 0.00 | 0.00 | 0.315189E+09 | 0.289004E+09 | 1465.57 | 22-JUL-18:00 | 1465.57 | 0.00 |
| August | 0.00 | 0.00 | 0.228362E+09 | 0.208897E+09 | 977.75 | 14-AUG-16:50 | 955.41 | 0.00 |
| September | 0.00 | 0.00 | 38744785.36 | 35020047.12 | 662.00 | 13-SEP-16:20 | 602.25 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.692603E+09 | 0.633013E+09 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.315189E+09 | 0.289004E+09 | 1465.57 | 1465.57 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 757326.33 | 757326.33 | 124.19 | 30-APR-19:00 | 124.19 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 70535328.64 | 62902724.79 | 793.01 | 13-JUN-17:00 | 712.51 | 0.00 |
| July | 0.00 | 0.00 | 0.252420E+09 | 0.229554E+09 | 1250.02 | 22-JUL-18:00 | 1250.02 | 0.00 |
| August | 0.00 | 0.00 | 0.159482E+09 | 0.144682E+09 | 855.20 | 14-AUG-18:00 | 855.20 | 0.00 |
| September | 0.00 | 0.00 | 20053896.35 | 18155806.99 | 529.71 | 13-SEP-16:40 | 479.29 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.503248E+09 | 0.456052E+09 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.252420E+09 | 0.229554E+09 | 1250.02 | 1250.02 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 841369.19 | 841369.19 | 129.84 | 30-APR-19:00 | 129.84 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 70394015.40 | 62782898.12 | 783.73 | 13-JUN-17:00 | 704.01 | 0.00 |
| July | 0.00 | 0.00 | 0.250522E+09 | 0.227922E+09 | 1242.59 | 22-JUL-18:00 | 1242.59 | 0.00 |
| August | 0.00 | 0.00 | 0.163021E+09 | 0.147962E+09 | 851.82 | 14-AUG-18:00 | 851.82 | 0.00 |
| September | 0.00 | 0.00 | 22069411.84 | 19949586.38 | 537.25 | 13-SEP-16:40 | 486.40 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.506848E+09 | 0.459458E+09 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.250522E+09 | 0.227922E+09 | 1242.59 | 1242.59 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 50811677.74 | 50811677.74 | 1114.89 | 30-APR-16:10 | 1114.89 | 0.00 |
| May | 0.00 | 0.00 | 18007421.32 | 17289113.98 | 449.05 | 22-MAY-15:10 | 430.26 | 0.00 |
| June | 0.00 | 0.00 | 0.230259E+09 | 0.211328E+09 | 1222.81 | 13-JUN-16:05 | 1133.22 | 0.00 |
| July | 0.00 | 0.00 | 0.663741E+09 | 0.608334E+09 | 1693.57 | 22-JUL-16:10 | 1693.57 | 0.00 |
| August | 0.00 | 0.00 | 0.890919E+09 | 0.823871E+09 | 1529.59 | 14-AUG-15:10 | 1459.45 | 0.00 |
| September | 0.00 | 0.00 | 0.765358E+09 | 0.724121E+09 | 1533.34 | 13-SEP-15:10 | 1435.66 | 0.00 |
| October | 0.00 | 0.00 | 98864379.80 | 98787133.35 | 709.43 | 03-OCT-15:10 | 709.43 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.271796E+10 | 0.253454E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.890919E+09 | 0.823871E+09 | 1693.57 | 1693.57 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 58207816.13 | 58207816.13 | 1183.00 | 30-APR-16:10 | 1183.00 | 0.00 |
| May | 0.00 | 0.00 | 21589932.33 | 20765496.82 | 463.88 | 22-MAY-15:10 | 444.57 | 0.00 |
| June | 0.00 | 0.00 | 0.259726E+09 | 0.238573E+09 | 1259.21 | 13-JUN-16:05 | 1168.66 | 0.00 |
| July | 0.00 | 0.00 | 0.740773E+09 | 0.679295E+09 | 1784.06 | 22-JUL-16:10 | 1784.06 | 0.00 |
| August | 0.00 | 0.00 | 0.993323E+09 | 0.919272E+09 | 1577.62 | 14-AUG-15:10 | 1507.35 | 0.00 |
| September | 0.00 | 0.00 | 0.839108E+09 | 0.794252E+09 | 1579.28 | 13-SEP-15:10 | 1480.25 | 0.00 |
| October | 0.00 | 0.00 | 0.107889E+09 | 0.107784E+09 | 741.57 | 03-OCT-15:10 | 741.57 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.302062E+10 | 0.281815E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.993323E+09 | 0.919272E+09 | 1784.06 | 1784.06 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.108184E+10 | 0.108183E+10 | 5584.73 | 30-APR-16:10 | 5584.73 | 0.00 |
| May | 0.00 | 0.00 | 0.103663E+10 | 0.101960E+10 | 4466.94 | 22-MAY-15:20 | 4337.21 | 0.00 |
| June | 0.00 | 0.00 | 0.235628E+10 | 0.223158E+10 | 5707.89 | 13-JUN-17:10 | 5469.00 | 0.00 |
| July | 0.00 | 0.00 | 0.334805E+10 | 0.312939E+10 | 5922.37 | 22-JUL-16:20 | 5922.37 | 0.00 |
| August | 0.00 | 0.00 | 0.353667E+10 | 0.330633E+10 | 5565.45 | 14-AUG-16:03 | 5524.41 | 0.00 |
| September | 0.00 | 0.00 | 0.277006E+10 | 0.264315E+10 | 5287.44 | 12-SEP-15:10 | 4906.35 | 0.00 |
| October | 0.00 | 0.00 | 0.473380E+09 | 0.472021E+09 | 3126.19 | 07-OCT-15:10 | 3126.19 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.146029E+11 | 0.138839E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.353667E+10 | 0.330633E+10 | 5922.37 | 5922.37 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.245342E+09 | 0.245342E+09 | 3769.36 | 30-APR-17:30 | 3769.36 | 0.00 |
| May | 0.00 | 0.00 | 0.391129E+09 | 0.377618E+09 | 3161.21 | 22-MAY-16:10 | 3044.51 | 0.00 |
| June | 0.00 | 0.00 | 0.163323E+10 | 0.152967E+10 | 5126.08 | 13-JUN-17:10 | 4838.61 | 0.00 |
| July | 0.00 | 0.00 | 0.228995E+10 | 0.212161E+10 | 5084.64 | 22-JUL-18:00 | 5084.64 | 0.00 |
| August | 0.00 | 0.00 | 0.181715E+10 | 0.167696E+10 | 4133.94 | 14-AUG-16:23 | 4062.18 | 0.00 |
| September | 0.00 | 0.00 | 0.678816E+09 | 0.630793E+09 | 3397.68 | 13-SEP-16:30 | 3162.71 | 0.00 |
| October | 0.00 | 0.00 | 326087.69 | 326087.69 | 130.45 | 02-OCT-16:02 | 130.45 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.705595E+10 | 0.658232E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.228995E+10 | 0.212161E+10 | 5126.08 | 5084.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.117011E+10 | 0.117008E+10 | 4768.97 | 30-APR-14:10 | 4768.97 | 0.00 |
| May | 0.00 | 0.00 | 0.102854E+10 | 0.101277E+10 | 3791.13 | 22-MAY-14:40 | 3684.82 | 0.00 |
| June | 0.00 | 0.00 | 0.230177E+10 | 0.217918E+10 | 4637.25 | 13-JUN-14:10 | 4355.59 | 0.00 |
| July | 0.00 | 0.00 | 0.327787E+10 | 0.306744E+10 | 5323.38 | 22-JUL-12:40 | 5163.75 | 0.00 |
| August | 0.00 | 0.00 | 0.369419E+10 | 0.345422E+10 | 4943.47 | 14-AUG-13:00 | 4568.88 | 0.00 |
| September | 0.00 | 0.00 | 0.297248E+10 | 0.284004E+10 | 4780.70 | 12-SEP-14:20 | 4306.00 | 0.00 |
| October | 0.00 | 0.00 | 0.500890E+09 | 0.499559E+09 | 2612.04 | 07-OCT-15:10 | 2612.04 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.149458E+11 | 0.142233E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.369419E+10 | 0.345422E+10 | 5323.38 | 5163.75 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.261735E+09 | 0.261731E+09 | 2631.32 | 30-APR-17:20 | 2631.32 | 0.00 |
| May | 0.00 | 0.00 | 0.342366E+09 | 0.330418E+09 | 2391.09 | 23-MAY-10:00 | 2214.42 | 0.00 |
| June | 0.00 | 0.00 | 0.157816E+10 | 0.147691E+10 | 3730.74 | 13-JUN-17:00 | 3488.53 | 0.00 |
| July | 0.00 | 0.00 | 0.221706E+10 | 0.205893E+10 | 3926.49 | 22-JUL-18:30 | 3926.49 | 0.00 |
| August | 0.00 | 0.00 | 0.196806E+10 | 0.181553E+10 | 3082.19 | 14-AUG-17:30 | 3082.19 | 0.00 |
| September | 0.00 | 0.00 | 0.772777E+09 | 0.719057E+09 | 2437.54 | 13-SEP-16:12 | 2251.37 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.714015E+10 | 0.666257E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.221706E+10 | 0.205893E+10 | 3926.49 | 3926.49 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.125407E+09 | 0.125407E+09 | 2181.78 | 30-APR-18:50 | 2181.78 | 0.00 |
| May | 0.00 | 0.00 | 0.207709E+09 | 0.199606E+09 | 1534.96 | 22-MAY-16:10 | 1465.74 | 0.00 |
| June | 0.00 | 0.00 | 0.127353E+10 | 0.118045E+10 | 3008.74 | 13-JUN-17:10 | 2792.32 | 0.00 |
| July | 0.00 | 0.00 | 0.173753E+10 | 0.159702E+10 | 3242.95 | 22-JUL-18:30 | 3242.95 | 0.00 |
| August | 0.00 | 0.00 | 0.147373E+10 | 0.134675E+10 | 2555.43 | 14-AUG-18:00 | 2555.43 | 0.00 |
| September | 0.00 | 0.00 | 0.578965E+09 | 0.532692E+09 | 2030.77 | 13-SEP-16:40 | 1869.05 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.539687E+10 | 0.498193E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.173753E+10 | 0.159702E+10 | 3242.95 | 3242.95 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.131444E+09 | 0.131444E+09 | 2172.47 | 30-APR-18:50 | 2172.47 | 0.00 |
| May | 0.00 | 0.00 | 0.208893E+09 | 0.200766E+09 | 1538.23 | 22-MAY-16:05 | 1469.72 | 0.00 |
| June | 0.00 | 0.00 | 0.127162E+10 | 0.117877E+10 | 2989.42 | 13-JUN-17:10 | 2774.20 | 0.00 |
| July | 0.00 | 0.00 | 0.173706E+10 | 0.159725E+10 | 3224.08 | 22-JUL-18:30 | 3224.08 | 0.00 |
| August | 0.00 | 0.00 | 0.148120E+10 | 0.135375E+10 | 2540.10 | 14-AUG-17:50 | 2540.10 | 0.00 |
| September | 0.00 | 0.00 | 0.596065E+09 | 0.548868E+09 | 2022.06 | 13-SEP-16:40 | 1861.04 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.542628E+10 | 0.501085E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.173706E+10 | 0.159725E+10 | 3224.08 | 3224.08 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.100721E+10 | 0.100719E+10 | 4110.00 | 30-APR-15:10 | 4110.00 | 0.00 |
| May | 0.00 | 0.00 | 0.889398E+09 | 0.875789E+09 | 3144.53 | 22-MAY-15:10 | 3045.28 | 0.00 |
| June | 0.00 | 0.00 | 0.202338E+10 | 0.190497E+10 | 3766.62 | 13-JUN-15:10 | 3539.93 | 0.00 |
| July | 0.00 | 0.00 | 0.282453E+10 | 0.262478E+10 | 4286.35 | 22-JUL-13:30 | 4230.95 | 0.00 |
| August | 0.00 | 0.00 | 0.326058E+10 | 0.303334E+10 | 4123.59 | 14-AUG-14:20 | 3890.01 | 0.00 |
| September | 0.00 | 0.00 | 0.286997E+10 | 0.273588E+10 | 4198.47 | 12-SEP-14:30 | 3773.99 | 0.00 |
| October | 0.00 | 0.00 | 0.603827E+09 | 0.601001E+09 | 2675.06 | 03-OCT-14:10 | 2675.06 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.134789E+11 | 0.127830E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.326058E+10 | 0.303334E+10 | 4286.35 | 4230.95 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.102388E+10 | 0.102386E+10 | 4110.25 | 30-APR-15:10 | 4110.25 | 0.00 |
| May | 0.00 | 0.00 | 0.898392E+09 | 0.884793E+09 | 3147.16 | 22-MAY-15:10 | 3047.97 | 0.00 |
| June | 0.00 | 0.00 | 0.202131E+10 | 0.190312E+10 | 3765.78 | 13-JUN-15:10 | 3539.54 | 0.00 |
| July | 0.00 | 0.00 | 0.282396E+10 | 0.262479E+10 | 4300.42 | 22-JUL-13:30 | 4245.32 | 0.00 |
| August | 0.00 | 0.00 | 0.326665E+10 | 0.303918E+10 | 4132.36 | 14-AUG-14:20 | 3899.05 | 0.00 |
| September | 0.00 | 0.00 | 0.288238E+10 | 0.274802E+10 | 4206.68 | 12-SEP-14:30 | 3782.17 | 0.00 |
| October | 0.00 | 0.00 | 0.607242E+09 | 0.604400E+09 | 2682.69 | 03-OCT-14:10 | 2682.69 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.135238E+11 | 0.128282E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.326665E+10 | 0.303918E+10 | 4300.42 | 4245.32 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 2635833.07 | 2635833.07 | 316.82 | 15-JAN-15:00 | 316.82 | 0.00 |
| February | 0.00 | 0.00 | 17203967.62 | 17203967.62 | 745.77 | 27-FEB-16:10 | 745.77 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.631569E+09 | 0.631569E+09 | 3614.01 | 30-APR-16:10 | 3614.01 | 0.00 |
| May | 0.00 | 0.00 | 0.569624E+09 | 0.560485E+09 | 3096.96 | 22-MAY-15:30 | 3017.70 | 0.00 |
| June | 0.00 | 0.00 | 0.106312E+10 | 0.101368E+10 | 3792.89 | 13-JUN-16:25 | 3641.18 | 0.00 |
| July | 0.00 | 0.00 | 0.156744E+10 | 0.147781E+10 | 3972.87 | 22-JUL-16:10 | 3972.87 | 0.00 |
| August | 0.00 | 0.00 | 0.156772E+10 | 0.147387E+10 | 3556.00 | 14-AUG-16:03 | 3540.78 | 0.00 |
| September | 0.00 | 0.00 | 0.110775E+10 | 0.106060E+10 | 3256.40 | 12-SEP-15:10 | 3037.35 | 0.00 |
| October | 0.00 | 0.00 | 0.205954E+09 | 0.205569E+09 | 2060.51 | 07-OCT-15:20 | 2060.51 | 0.00 |
| November | 0.00 | 0.00 | 1859155.39 | 1859155.39 | 226.78 | 11-NOV-14:20 | 226.78 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.673488E+10 | 0.644529E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.156772E+10 | 0.147781E+10 | 3972.87 | 3972.87 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.185146E+09 | 0.185146E+09 | 2461.05 | 30-APR-17:20 | 2461.05 | 0.00 |
| May | 0.00 | 0.00 | 0.248739E+09 | 0.241052E+09 | 2384.55 | 22-MAY-16:10 | 2310.70 | 0.00 |
| June | 0.00 | 0.00 | 0.703084E+09 | 0.662545E+09 | 3430.87 | 13-JUN-17:10 | 3270.46 | 0.00 |
| July | 0.00 | 0.00 | 0.103537E+10 | 0.967624E+09 | 3337.21 | 22-JUL-17:50 | 3337.21 | 0.00 |
| August | 0.00 | 0.00 | 0.731085E+09 | 0.678723E+09 | 2659.77 | 14-AUG-16:23 | 2628.46 | 0.00 |
| September | 0.00 | 0.00 | 0.245300E+09 | 0.228602E+09 | 2065.04 | 13-SEP-16:30 | 1927.93 | 0.00 |
| October | 0.00 | 0.00 | 817147.60 | 817147.60 | 158.64 | 07-OCT-17:00 | 158.64 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.314954E+10 | 0.296451E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.103537E+10 | 0.967624E+09 | 3430.87 | 3337.21 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 1869198.16 | 1869198.16 | 319.16 | 15-JAN-13:10 | 319.16 | 0.00 |
| February | 0.00 | 0.00 | 4890999.08 | 4890999.08 | 535.54 | 04-FEB-14:20 | 535.54 | 0.00 |
| March | 0.00 | 0.00 | 1112933.69 | 1112933.69 | 201.48 | 25-MAR-12:00 | 201.48 | 0.00 |
| April | 0.00 | 0.00 | 0.624582E+09 | 0.624582E+09 | 3070.01 | 30-APR-14:00 | 3070.01 | 0.00 |
| May | 0.00 | 0.00 | 0.526112E+09 | 0.517957E+09 | 2624.66 | 22-MAY-14:30 | 2558.13 | 0.00 |
| June | 0.00 | 0.00 | 0.101119E+10 | 0.962898E+09 | 3158.27 | 13-JUN-13:30 | 2976.71 | 0.00 |
| July | 0.00 | 0.00 | 0.149398E+10 | 0.140782E+10 | 3578.47 | 22-JUL-13:30 | 3563.81 | 0.00 |
| August | 0.00 | 0.00 | 0.161424E+10 | 0.151619E+10 | 3114.95 | 14-AUG-13:10 | 2900.34 | 0.00 |
| September | 0.00 | 0.00 | 0.115454E+10 | 0.110566E+10 | 2925.06 | 12-SEP-14:10 | 2644.49 | 0.00 |
| October | 0.00 | 0.00 | 0.206579E+09 | 0.206288E+09 | 1654.57 | 07-OCT-15:10 | 1654.57 | 0.00 |
| November | 0.00 | 0.00 | 813964.05 | 813964.05 | 182.80 | 11-NOV-13:40 | 182.80 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.663991E+10 | 0.635009E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.161424E+10 | 0.151619E+10 | 3578.47 | 3563.81 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.145274E+09 | 0.145274E+09 | 1655.99 | 30-APR-16:20 | 1655.99 | 0.00 |
| May | 0.00 | 0.00 | 0.187702E+09 | 0.181051E+09 | 1721.35 | 22-MAY-15:10 | 1650.88 | 0.00 |
| June | 0.00 | 0.00 | 0.634759E+09 | 0.595617E+09 | 2425.37 | 13-JUN-16:12 | 2274.42 | 0.00 |
| July | 0.00 | 0.00 | 0.935490E+09 | 0.872452E+09 | 2534.92 | 22-JUL-16:20 | 2534.92 | 0.00 |
| August | 0.00 | 0.00 | 0.742958E+09 | 0.687200E+09 | 1894.93 | 14-AUG-16:12 | 1862.01 | 0.00 |
| September | 0.00 | 0.00 | 0.201061E+09 | 0.185680E+09 | 1382.66 | 13-SEP-16:05 | 1278.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.284724E+10 | 0.266727E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.935490E+09 | 0.872452E+09 | 2534.92 | 2534.92 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 72867359.43 | 72867359.43 | 1336.86 | 30-APR-16:30 | 1336.86 | 0.00 |
| May | 0.00 | 0.00 | 97779366.42 | 93243964.86 | 1323.69 | 22-MAY-15:20 | 1265.06 | 0.00 |
| June | 0.00 | 0.00 | 0.437300E+09 | 0.405531E+09 | 2055.86 | 13-JUN-17:00 | 1931.84 | 0.00 |
| July | 0.00 | 0.00 | 0.664905E+09 | 0.614330E+09 | 2126.62 | 22-JUL-18:00 | 2126.62 | 0.00 |
| August | 0.00 | 0.00 | 0.459338E+09 | 0.421786E+09 | 1580.32 | 14-AUG-16:23 | 1545.54 | 0.00 |
| September | 0.00 | 0.00 | 0.103295E+09 | 94317195.70 | 1152.52 | 13-SEP-16:30 | 1060.91 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.183548E+10 | 0.170208E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.664905E+09 | 0.614330E+09 | 2126.62 | 2126.62 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 74784678.07 | 74784678.07 | 1329.77 | 30-APR-16:30 | 1329.77 | 0.00 |
| May | 0.00 | 0.00 | 99501676.40 | 94917442.43 | 1329.39 | 22-MAY-15:10 | 1270.56 | 0.00 |
| June | 0.00 | 0.00 | 0.440265E+09 | 0.408396E+09 | 2033.42 | 13-JUN-17:00 | 1910.45 | 0.00 |
| July | 0.00 | 0.00 | 0.666604E+09 | 0.616126E+09 | 2104.24 | 22-JUL-18:00 | 2104.24 | 0.00 |
| August | 0.00 | 0.00 | 0.468061E+09 | 0.429907E+09 | 1567.21 | 14-AUG-16:23 | 1533.08 | 0.00 |
| September | 0.00 | 0.00 | 0.106311E+09 | 97098643.69 | 1144.52 | 13-SEP-16:12 | 1052.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.185553E+10 | 0.172123E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.666604E+09 | 0.616126E+09 | 2104.24 | 2104.24 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 3758290.36 | 3758290.36 | 420.74 | 15-JAN-13:40 | 420.74 | 0.00 |
| February | 0.00 | 0.00 | 12318837.35 | 12318837.35 | 743.37 | 04-FEB-14:30 | 743.37 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.479463E+09 | 0.479463E+09 | 2687.89 | 30-APR-14:20 | 2687.89 | 0.00 |
| May | 0.00 | 0.00 | 0.389649E+09 | 0.382778E+09 | 2226.49 | 22-MAY-15:10 | 2162.00 | 0.00 |
| June | 0.00 | 0.00 | 0.803821E+09 | 0.761187E+09 | 2675.97 | 13-JUN-14:10 | 2524.95 | 0.00 |
| July | 0.00 | 0.00 | 0.121397E+10 | 0.113717E+10 | 3016.58 | 22-JUL-13:40 | 2998.56 | 0.00 |
| August | 0.00 | 0.00 | 0.132583E+10 | 0.124041E+10 | 2698.81 | 14-AUG-14:20 | 2566.07 | 0.00 |
| September | 0.00 | 0.00 | 0.986470E+09 | 0.941901E+09 | 2615.68 | 12-SEP-14:30 | 2363.59 | 0.00 |
| October | 0.00 | 0.00 | 0.185706E+09 | 0.185371E+09 | 1564.13 | 07-OCT-15:10 | 1564.13 | 0.00 |
| November | 0.00 | 0.00 | 3042810.39 | 3042810.39 | 361.44 | 11-NOV-13:40 | 361.44 | 0.00 |
| December | 0.00 | 0.00 | 20417.49 | 20417.49 | 19.55 | 18-DEC-14:30 | 19.55 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.540405E+10 | 0.514742E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.132583E+10 | 0.124041E+10 | 3016.58 | 2998.56 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 COOLING COIL
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 3861602.68 | 3861602.68 | 433.28 | 15-JAN-13:40 | 433.28 | 0.00 |
| February | 0.00 | 0.00 | 12287534.58 | 12287534.58 | 751.27 | 04-FEB-14:30 | 751.27 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.487218E+09 | 0.487218E+09 | 2697.79 | 30-APR-14:20 | 2697.79 | 0.00 |
| May | 0.00 | 0.00 | 0.395800E+09 | 0.388928E+09 | 2232.37 | 22-MAY-14:40 | 2171.11 | 0.00 |
| June | 0.00 | 0.00 | 0.808330E+09 | 0.765645E+09 | 2682.28 | 13-JUN-14:10 | 2531.62 | 0.00 |
| July | 0.00 | 0.00 | 0.121740E+10 | 0.114071E+10 | 3028.01 | 22-JUL-13:40 | 3010.26 | 0.00 |
| August | 0.00 | 0.00 | 0.133468E+10 | 0.124886E+10 | 2706.10 | 14-AUG-14:20 | 2573.86 | 0.00 |
| September | 0.00 | 0.00 | 0.996566E+09 | 0.951759E+09 | 2625.48 | 12-SEP-14:20 | 2367.05 | 0.00 |
| October | 0.00 | 0.00 | 0.188992E+09 | 0.188654E+09 | 1564.23 | 07-OCT-15:10 | 1564.23 | 0.00 |
| November | 0.00 | 0.00 | 3198715.28 | 3198715.28 | 377.66 | 11-NOV-13:40 | 377.66 | 0.00 |
| December | 0.00 | 0.00 | 42809.93 | 42809.93 | 37.94 | 18-DEC-14:00 | 37.94 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.544838E+10 | 0.519116E+10 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.133468E+10 | 0.124886E+10 | 3028.01 | 3010.26 | 0.00 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 75702944.31 | 0.89 | 67.20 | 10-JAN-06:00 | 0.93 |
| February | 64933660.26 | 0.87 | 61.26 | 17-FEB-04:00 | 0.93 |
| March | 70379482.53 | 0.91 | 50.32 | 16-MAR-04:00 | 0.93 |
| April | 21095350.18 | 0.42 | 115.42 | 30-APR-16:10 | 1.04 |
| May | 12706716.26 | 0.31 | 60.81 | 22-MAY-16:10 | 1.06 |
| June | 21648607.46 | 0.26 | 136.83 | 13-JUN-17:00 | 1.03 |
| July | 58713403.54 | 0.51 | 172.04 | 22-JUL-17:30 | 1.01 |
| August | 65866211.46 | 0.60 | 149.63 | 14-AUG-16:12 | 1.02 |
| September | 49634037.96 | 0.48 | 141.76 | 13-SEP-16:05 | 1.02 |
| October | 19987339.26 | 0.47 | 59.70 | 03-OCT-16:04 | 1.06 |
| November | 47034773.20 | 0.85 | 50.81 | 29-NOV-04:00 | 0.93 |
| December | 93297081.82 | 0.92 | 63.81 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.601000E+09 | 0.62 | |||
| Minimum of Months | 12706716.26 | 0.26 | 50.32 | 0.93 | |
| Maximum of Months | 93297081.82 | 0.92 | 172.04 | 1.06 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.101556E+09 | 0.93 | 74.59 | 10-JAN-09:00 | 0.93 |
| February | 89552812.91 | 0.93 | 64.64 | 17-FEB-04:00 | 0.93 |
| March | 81267255.70 | 0.93 | 51.12 | 04-MAR-06:00 | 0.93 |
| April | 32901695.62 | 0.68 | 43.85 | 30-APR-17:40 | 1.07 |
| May | 17927340.39 | 0.46 | 46.65 | 21-MAY-07:01 | 0.92 |
| June | 9964560.32 | 0.15 | 105.02 | 13-JUN-17:10 | 1.03 |
| July | 29604683.71 | 0.34 | 142.66 | 22-JUL-18:00 | 1.01 |
| August | 17201133.91 | 0.30 | 98.56 | 14-AUG-17:05 | 1.03 |
| September | 3079069.06 | 0.06 | 66.09 | 13-SEP-16:30 | 1.05 |
| October | 28574056.98 | 0.67 | 43.27 | 24-OCT-16:01 | 0.92 |
| November | 66567714.14 | 0.93 | 59.68 | 29-NOV-04:00 | 0.93 |
| December | 0.108808E+09 | 0.93 | 68.30 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.587004E+09 | 0.61 | |||
| Minimum of Months | 3079069.06 | 0.06 | 43.27 | 0.92 | |
| Maximum of Months | 0.108808E+09 | 0.93 | 142.66 | 1.07 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.110764E+10 | 0.93 | 413.54 | 01-JAN-00:10 | 0.93 |
| February | 0.100044E+10 | 0.93 | 413.54 | 01-FEB-00:10 | 0.93 |
| March | 0.110764E+10 | 0.93 | 413.54 | 01-MAR-00:10 | 0.93 |
| April | 0.107191E+10 | 0.93 | 413.54 | 01-APR-00:10 | 0.93 |
| May | 0.110764E+10 | 0.93 | 413.54 | 01-MAY-00:10 | 0.93 |
| June | 0.107191E+10 | 0.92 | 413.54 | 01-JUN-00:10 | 0.92 |
| July | 0.110764E+10 | 0.92 | 413.54 | 01-JUL-00:10 | 0.92 |
| August | 0.110764E+10 | 0.92 | 413.54 | 01-AUG-00:10 | 0.92 |
| September | 0.107191E+10 | 0.92 | 413.54 | 01-SEP-00:10 | 0.92 |
| October | 0.110764E+10 | 0.92 | 413.54 | 01-OCT-00:10 | 0.93 |
| November | 0.107191E+10 | 0.93 | 413.54 | 01-NOV-00:10 | 0.93 |
| December | 0.110764E+10 | 0.93 | 413.54 | 01-DEC-00:10 | 0.93 |
| Annual Sum or Average | 0.130415E+11 | 0.93 | |||
| Minimum of Months | 0.100044E+10 | 0.92 | 413.54 | 0.92 | |
| Maximum of Months | 0.110764E+10 | 0.93 | 413.54 | 0.93 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 99530870.69 | 0.93 | 73.67 | 12-JAN-00:10 | 0.93 |
| February | 89392541.16 | 0.93 | 66.00 | 17-FEB-04:00 | 0.93 |
| March | 79719134.25 | 0.93 | 51.83 | 04-MAR-06:00 | 0.93 |
| April | 29341297.17 | 0.64 | 40.01 | 01-APR-05:00 | 0.93 |
| May | 16199383.65 | 0.42 | 35.03 | 06-MAY-04:50 | 0.93 |
| June | 8881779.32 | 0.14 | 75.15 | 13-JUN-17:00 | 1.04 |
| July | 24241084.97 | 0.32 | 114.34 | 22-JUL-18:00 | 1.02 |
| August | 17718041.24 | 0.34 | 76.65 | 14-AUG-17:40 | 1.04 |
| September | 3012384.96 | 0.07 | 50.70 | 13-SEP-16:20 | 1.05 |
| October | 27411064.94 | 0.65 | 51.80 | 24-OCT-16:01 | 0.92 |
| November | 65252060.72 | 0.93 | 57.85 | 29-NOV-04:00 | 0.93 |
| December | 0.105383E+09 | 0.93 | 67.71 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.566083E+09 | 0.60 | |||
| Minimum of Months | 3012384.96 | 0.07 | 35.03 | 0.92 | |
| Maximum of Months | 0.105383E+09 | 0.93 | 114.34 | 1.05 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 67619800.68 | 0.93 | 54.17 | 12-JAN-00:10 | 0.93 |
| February | 60732045.61 | 0.93 | 46.27 | 18-FEB-04:00 | 0.93 |
| March | 51775432.99 | 0.93 | 34.59 | 08-MAR-05:00 | 0.93 |
| April | 20071305.72 | 0.61 | 27.31 | 01-APR-05:00 | 0.93 |
| May | 8554686.92 | 0.35 | 24.15 | 06-MAY-04:50 | 0.93 |
| June | 5478317.05 | 0.12 | 60.81 | 13-JUN-17:00 | 1.04 |
| July | 19507096.95 | 0.35 | 98.11 | 22-JUL-18:00 | 1.02 |
| August | 12389539.48 | 0.31 | 67.35 | 14-AUG-18:00 | 1.04 |
| September | 1562937.37 | 0.05 | 40.70 | 13-SEP-16:40 | 1.06 |
| October | 13472670.93 | 0.53 | 21.40 | 23-OCT-04:00 | 0.93 |
| November | 40494261.96 | 0.92 | 41.04 | 29-NOV-02:00 | 0.93 |
| December | 70614761.07 | 0.93 | 47.43 | 30-DEC-02:70 | 0.93 |
| Annual Sum or Average | 0.372273E+09 | 0.58 | |||
| Minimum of Months | 1562937.37 | 0.05 | 21.40 | 0.93 | |
| Maximum of Months | 70614761.07 | 0.93 | 98.11 | 1.06 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 67570348.89 | 0.93 | 54.16 | 12-JAN-00:10 | 0.93 |
| February | 60769672.95 | 0.93 | 46.33 | 18-FEB-04:00 | 0.93 |
| March | 51752259.54 | 0.93 | 34.57 | 08-MAR-05:00 | 0.93 |
| April | 19908454.86 | 0.61 | 27.31 | 01-APR-05:00 | 0.93 |
| May | 8448143.10 | 0.34 | 24.13 | 06-MAY-04:50 | 0.93 |
| June | 5473525.88 | 0.12 | 60.11 | 13-JUN-17:00 | 1.04 |
| July | 19359592.27 | 0.34 | 97.54 | 22-JUL-18:00 | 1.02 |
| August | 12664759.14 | 0.32 | 67.08 | 14-AUG-18:00 | 1.04 |
| September | 1719230.05 | 0.05 | 41.26 | 13-SEP-16:40 | 1.06 |
| October | 13427176.24 | 0.53 | 21.39 | 23-OCT-04:00 | 0.93 |
| November | 40468521.96 | 0.92 | 40.95 | 29-NOV-02:00 | 0.93 |
| December | 70503610.47 | 0.93 | 47.42 | 30-DEC-02:70 | 0.93 |
| Annual Sum or Average | 0.372065E+09 | 0.58 | |||
| Minimum of Months | 1719230.05 | 0.05 | 21.39 | 0.93 | |
| Maximum of Months | 70503610.47 | 0.93 | 97.54 | 1.06 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 43753708.39 | 0.83 | 45.41 | 10-JAN-08:20 | 0.93 |
| February | 38167627.27 | 0.81 | 42.52 | 17-FEB-04:00 | 0.93 |
| March | 41828665.14 | 0.88 | 33.80 | 16-MAR-04:00 | 0.93 |
| April | 10720466.63 | 0.28 | 87.62 | 30-APR-16:10 | 1.05 |
| May | 4070737.54 | 0.17 | 35.23 | 22-MAY-15:10 | 1.07 |
| June | 17818314.22 | 0.31 | 93.54 | 13-JUN-16:05 | 1.04 |
| July | 51192897.54 | 0.60 | 131.22 | 22-JUL-16:10 | 1.02 |
| August | 68768230.12 | 0.79 | 116.10 | 14-AUG-16:03 | 1.03 |
| September | 59400911.91 | 0.68 | 115.30 | 13-SEP-15:10 | 1.03 |
| October | 12305257.14 | 0.34 | 56.53 | 03-OCT-15:10 | 1.06 |
| November | 22604563.80 | 0.71 | 32.83 | 29-NOV-04:00 | 0.93 |
| December | 56381760.54 | 0.90 | 43.11 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.427013E+09 | 0.61 | |||
| Minimum of Months | 4070737.54 | 0.17 | 32.83 | 0.93 | |
| Maximum of Months | 68768230.12 | 0.90 | 131.22 | 1.07 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 49585992.25 | 0.85 | 49.77 | 10-JAN-08:20 | 0.93 |
| February | 42838106.88 | 0.84 | 45.54 | 17-FEB-04:00 | 0.93 |
| March | 46304245.13 | 0.89 | 36.50 | 16-MAR-04:00 | 0.93 |
| April | 11777864.12 | 0.29 | 92.76 | 30-APR-16:10 | 1.04 |
| May | 4011695.97 | 0.16 | 36.38 | 22-MAY-15:10 | 1.07 |
| June | 20098829.67 | 0.33 | 96.25 | 13-JUN-16:05 | 1.04 |
| July | 57073122.44 | 0.63 | 137.84 | 22-JUL-16:10 | 1.02 |
| August | 76623949.23 | 0.84 | 119.40 | 14-AUG-15:10 | 1.03 |
| September | 65081630.91 | 0.73 | 118.62 | 13-SEP-15:10 | 1.03 |
| October | 13043399.86 | 0.33 | 59.03 | 03-OCT-15:10 | 1.06 |
| November | 25020941.54 | 0.74 | 34.97 | 29-NOV-04:00 | 0.93 |
| December | 62845691.45 | 0.91 | 46.39 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.474305E+09 | 0.63 | |||
| Minimum of Months | 4011695.97 | 0.16 | 34.97 | 0.93 | |
| Maximum of Months | 76623949.23 | 0.91 | 137.84 | 1.07 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 78499738.35 | 0.69 | 116.52 | 10-JAN-06:00 | 0.93 |
| February | 59698358.47 | 0.62 | 98.65 | 17-FEB-04:00 | 0.93 |
| March | 53392550.07 | 0.60 | 73.58 | 04-MAR-06:00 | 0.93 |
| April | 87008661.95 | 0.33 | 427.12 | 30-APR-16:10 | 1.02 |
| May | 81830995.11 | 0.34 | 338.68 | 22-MAY-15:30 | 1.03 |
| June | 0.182295E+09 | 0.70 | 428.99 | 13-JUN-17:10 | 1.01 |
| July | 0.257772E+09 | 0.84 | 454.49 | 22-JUL-16:20 | 1.01 |
| August | 0.272081E+09 | 0.90 | 421.92 | 14-AUG-16:03 | 1.01 |
| September | 0.214304E+09 | 0.71 | 393.31 | 12-SEP-15:10 | 1.02 |
| October | 45193425.44 | 0.31 | 248.35 | 07-OCT-15:10 | 1.05 |
| November | 52733347.46 | 0.59 | 95.04 | 29-NOV-04:00 | 0.93 |
| December | 0.134264E+09 | 0.87 | 115.28 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.151907E+10 | 0.62 | |||
| Minimum of Months | 45193425.44 | 0.31 | 73.58 | 0.93 | |
| Maximum of Months | 0.272081E+09 | 0.90 | 454.49 | 1.05 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.129277E+09 | 0.91 | 128.93 | 10-JAN-06:00 | 0.93 |
| February | 0.107273E+09 | 0.91 | 106.41 | 17-FEB-04:00 | 0.93 |
| March | 74522318.46 | 0.79 | 76.47 | 04-MAR-06:00 | 0.93 |
| April | 26661847.75 | 0.23 | 293.45 | 30-APR-17:30 | 1.03 |
| May | 31216289.93 | 0.18 | 241.60 | 22-MAY-16:10 | 1.04 |
| June | 0.126209E+09 | 0.62 | 383.23 | 13-JUN-17:10 | 1.01 |
| July | 0.176615E+09 | 0.78 | 393.80 | 22-JUL-18:00 | 1.01 |
| August | 0.140641E+09 | 0.72 | 318.58 | 14-AUG-17:05 | 1.02 |
| September | 52831977.71 | 0.36 | 256.75 | 13-SEP-16:30 | 1.03 |
| October | 22226827.95 | 0.36 | 52.60 | 28-OCT-07:00 | 0.92 |
| November | 93159716.02 | 0.87 | 111.96 | 29-NOV-04:00 | 0.93 |
| December | 0.167251E+09 | 0.93 | 125.38 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.114788E+10 | 0.64 | |||
| Minimum of Months | 22226827.95 | 0.18 | 52.60 | 0.92 | |
| Maximum of Months | 0.176615E+09 | 0.93 | 393.80 | 1.04 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 77099094.46 | 0.68 | 116.33 | 10-JAN-06:00 | 0.93 |
| February | 61069861.87 | 0.62 | 102.89 | 17-FEB-04:00 | 0.93 |
| March | 52593572.18 | 0.59 | 75.16 | 04-MAR-06:00 | 0.93 |
| April | 93862122.86 | 0.37 | 363.45 | 30-APR-14:10 | 1.02 |
| May | 81226583.23 | 0.38 | 287.66 | 22-MAY-14:40 | 1.03 |
| June | 0.177876E+09 | 0.69 | 347.05 | 13-JUN-14:10 | 1.02 |
| July | 0.251989E+09 | 0.85 | 402.82 | 22-JUL-13:00 | 1.01 |
| August | 0.283085E+09 | 0.90 | 365.41 | 14-AUG-13:00 | 1.01 |
| September | 0.229307E+09 | 0.74 | 352.47 | 12-SEP-14:20 | 1.01 |
| October | 46923232.16 | 0.32 | 207.73 | 07-OCT-15:10 | 1.05 |
| November | 51662002.98 | 0.59 | 92.20 | 29-NOV-04:00 | 0.93 |
| December | 0.129604E+09 | 0.86 | 115.32 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.153630E+10 | 0.63 | |||
| Minimum of Months | 46923232.16 | 0.32 | 75.16 | 0.93 | |
| Maximum of Months | 0.283085E+09 | 0.90 | 402.82 | 1.05 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.126723E+09 | 0.92 | 128.29 | 10-JAN-06:00 | 0.93 |
| February | 0.108465E+09 | 0.92 | 110.60 | 17-FEB-04:00 | 0.93 |
| March | 72587816.47 | 0.79 | 78.69 | 04-MAR-06:00 | 0.93 |
| April | 26909910.26 | 0.25 | 206.69 | 30-APR-17:20 | 1.04 |
| May | 27407884.01 | 0.19 | 182.03 | 23-MAY-10:00 | 1.04 |
| June | 0.122001E+09 | 0.65 | 281.55 | 13-JUN-17:00 | 1.02 |
| July | 0.171078E+09 | 0.80 | 304.84 | 22-JUL-18:30 | 1.02 |
| August | 0.152163E+09 | 0.76 | 239.65 | 14-AUG-17:30 | 1.03 |
| September | 60262523.95 | 0.47 | 185.15 | 13-SEP-16:20 | 1.04 |
| October | 20874315.37 | 0.35 | 52.19 | 28-OCT-07:00 | 0.92 |
| November | 91283998.47 | 0.88 | 108.52 | 29-NOV-04:00 | 0.93 |
| December | 0.161435E+09 | 0.93 | 125.18 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.114119E+10 | 0.66 | |||
| Minimum of Months | 20874315.37 | 0.19 | 52.19 | 0.92 | |
| Maximum of Months | 0.171078E+09 | 0.93 | 304.84 | 1.04 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 72738424.81 | 0.82 | 84.67 | 12-JAN-00:10 | 0.93 |
| February | 61844977.79 | 0.87 | 71.73 | 17-FEB-04:00 | 0.93 |
| March | 34355233.20 | 0.60 | 47.88 | 04-MAR-06:00 | 0.93 |
| April | 11485931.93 | 0.13 | 171.99 | 30-APR-18:50 | 1.05 |
| May | 16369632.03 | 0.16 | 118.98 | 22-MAY-16:10 | 1.05 |
| June | 98793693.67 | 0.74 | 227.98 | 13-JUN-17:00 | 1.03 |
| July | 0.134576E+09 | 0.87 | 253.40 | 22-JUL-18:30 | 1.02 |
| August | 0.114367E+09 | 0.88 | 200.03 | 14-AUG-18:00 | 1.04 |
| September | 45164907.28 | 0.49 | 154.74 | 13-SEP-16:50 | 1.04 |
| October | 3951446.79 | 0.12 | 25.21 | 23-OCT-04:00 | 0.93 |
| November | 43098230.25 | 0.71 | 71.00 | 29-NOV-04:00 | 0.93 |
| December | 94465140.35 | 0.93 | 80.91 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.731211E+09 | 0.61 | |||
| Minimum of Months | 3951446.79 | 0.12 | 25.21 | 0.93 | |
| Maximum of Months | 0.134576E+09 | 0.93 | 253.40 | 1.05 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 72678371.39 | 0.82 | 84.70 | 12-JAN-00:10 | 0.93 |
| February | 61988615.22 | 0.87 | 71.99 | 17-FEB-04:00 | 0.93 |
| March | 34378478.69 | 0.60 | 48.07 | 04-MAR-06:00 | 0.93 |
| April | 11926527.60 | 0.13 | 171.26 | 30-APR-18:50 | 1.05 |
| May | 16463341.54 | 0.16 | 119.23 | 22-MAY-16:05 | 1.05 |
| June | 98647040.14 | 0.74 | 226.67 | 13-JUN-17:00 | 1.03 |
| July | 0.134553E+09 | 0.87 | 251.96 | 22-JUL-18:30 | 1.02 |
| August | 0.114941E+09 | 0.88 | 198.82 | 14-AUG-18:00 | 1.04 |
| September | 46504896.26 | 0.50 | 154.03 | 13-SEP-16:40 | 1.04 |
| October | 3920071.40 | 0.12 | 25.36 | 23-OCT-04:00 | 0.93 |
| November | 43071214.74 | 0.71 | 70.94 | 29-NOV-04:00 | 0.93 |
| December | 94269912.55 | 0.93 | 80.93 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.733343E+09 | 0.61 | |||
| Minimum of Months | 3920071.40 | 0.12 | 25.36 | 0.93 | |
| Maximum of Months | 0.134553E+09 | 0.93 | 251.96 | 1.05 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 29852445.35 | 0.41 | 75.76 | 10-JAN-06:00 | 0.93 |
| February | 20387382.72 | 0.36 | 65.48 | 17-FEB-04:00 | 0.93 |
| March | 17126038.67 | 0.36 | 44.30 | 04-MAR-06:00 | 0.93 |
| April | 80447734.36 | 0.41 | 316.25 | 30-APR-15:10 | 1.02 |
| May | 70482711.07 | 0.42 | 239.97 | 22-MAY-15:10 | 1.04 |
| June | 0.157070E+09 | 0.83 | 285.02 | 13-JUN-15:10 | 1.03 |
| July | 0.218092E+09 | 0.94 | 330.19 | 22-JUL-15:10 | 1.02 |
| August | 0.251076E+09 | 1.02 | 308.99 | 14-AUG-14:30 | 1.02 |
| September | 0.222061E+09 | 0.87 | 310.86 | 12-SEP-14:30 | 1.02 |
| October | 48098328.85 | 0.22 | 210.82 | 07-OCT-15:10 | 1.05 |
| November | 13024174.27 | 0.23 | 52.57 | 29-NOV-04:00 | 0.93 |
| December | 63466207.84 | 0.73 | 74.14 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.119118E+10 | 0.57 | |||
| Minimum of Months | 13024174.27 | 0.22 | 44.30 | 0.93 | |
| Maximum of Months | 0.251076E+09 | 1.02 | 330.19 | 1.05 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 29806443.93 | 0.41 | 75.77 | 10-JAN-06:00 | 0.93 |
| February | 20512563.36 | 0.36 | 65.90 | 17-FEB-04:00 | 0.93 |
| March | 17155969.86 | 0.36 | 44.56 | 04-MAR-06:00 | 0.93 |
| April | 81780805.97 | 0.41 | 316.20 | 30-APR-15:10 | 1.02 |
| May | 71197250.65 | 0.43 | 240.12 | 22-MAY-15:10 | 1.04 |
| June | 0.156899E+09 | 0.82 | 284.92 | 13-JUN-15:10 | 1.02 |
| July | 0.218040E+09 | 0.94 | 330.16 | 22-JUL-15:10 | 1.02 |
| August | 0.251506E+09 | 1.02 | 309.44 | 14-AUG-14:20 | 1.02 |
| September | 0.222991E+09 | 0.87 | 311.39 | 12-SEP-14:30 | 1.02 |
| October | 48364806.25 | 0.22 | 210.91 | 07-OCT-15:10 | 1.05 |
| November | 12998646.71 | 0.23 | 52.32 | 29-NOV-04:00 | 0.93 |
| December | 63266918.68 | 0.73 | 74.17 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.119452E+10 | 0.57 | |||
| Minimum of Months | 12998646.71 | 0.22 | 44.56 | 0.93 | |
| Maximum of Months | 0.251506E+09 | 1.02 | 330.16 | 1.05 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.64 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.64 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.64 |
| September | 0.103716E+09 | 0.64 | 40.01 | 01-SEP-00:10 | 0.64 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.64 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.107173E+09 | 0.64 | 40.01 | 01-JAN-00:10 | 0.64 |
| February | 96801429.15 | 0.64 | 40.01 | 01-FEB-00:10 | 0.64 |
| March | 0.107173E+09 | 0.64 | 40.01 | 01-MAR-00:10 | 0.64 |
| April | 0.103716E+09 | 0.64 | 40.01 | 01-APR-00:10 | 0.64 |
| May | 0.107173E+09 | 0.64 | 40.01 | 01-MAY-00:10 | 0.64 |
| June | 0.103716E+09 | 0.63 | 40.01 | 01-JUN-00:10 | 0.63 |
| July | 0.107173E+09 | 0.63 | 40.01 | 01-JUL-00:10 | 0.63 |
| August | 0.107173E+09 | 0.63 | 40.01 | 01-AUG-00:10 | 0.63 |
| September | 0.103716E+09 | 0.63 | 40.01 | 01-SEP-00:10 | 0.63 |
| October | 0.107173E+09 | 0.64 | 40.01 | 01-OCT-00:10 | 0.64 |
| November | 0.103716E+09 | 0.64 | 40.01 | 01-NOV-00:10 | 0.64 |
| December | 0.107173E+09 | 0.64 | 40.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.126188E+10 | 0.64 | |||
| Minimum of Months | 96801429.15 | 0.63 | 40.01 | 0.63 | |
| Maximum of Months | 0.107173E+09 | 0.64 | 40.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.101769E+09 | 0.82 | 106.92 | 10-JAN-06:00 | 0.93 |
| February | 84661748.07 | 0.78 | 94.55 | 17-FEB-04:00 | 0.93 |
| March | 76240011.45 | 0.79 | 73.28 | 04-MAR-06:00 | 0.93 |
| April | 72869424.96 | 0.59 | 272.67 | 30-APR-16:10 | 1.00 |
| May | 65334689.76 | 0.56 | 231.37 | 22-MAY-15:30 | 1.01 |
| June | 83783294.78 | 0.46 | 280.97 | 13-JUN-16:25 | 1.00 |
| July | 0.120694E+09 | 0.52 | 299.63 | 22-JUL-16:10 | 0.99 |
| August | 0.119633E+09 | 0.51 | 266.36 | 14-AUG-16:03 | 1.00 |
| September | 89463762.47 | 0.51 | 240.24 | 12-SEP-15:10 | 1.01 |
| October | 58553925.79 | 0.68 | 162.31 | 07-OCT-15:20 | 1.04 |
| November | 82244617.51 | 0.81 | 91.69 | 29-NOV-04:00 | 0.93 |
| December | 0.134788E+09 | 0.89 | 102.85 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.109003E+10 | 0.66 | |||
| Minimum of Months | 58553925.79 | 0.46 | 73.28 | 0.93 | |
| Maximum of Months | 0.134788E+09 | 0.89 | 299.63 | 1.04 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.127827E+09 | 0.93 | 109.20 | 10-JAN-06:00 | 0.93 |
| February | 0.107665E+09 | 0.92 | 97.75 | 17-FEB-04:00 | 0.93 |
| March | 86978438.72 | 0.88 | 73.74 | 04-MAR-06:00 | 0.93 |
| April | 46528147.36 | 0.55 | 189.85 | 30-APR-17:20 | 1.02 |
| May | 43769127.97 | 0.51 | 179.69 | 22-MAY-16:10 | 1.02 |
| June | 56298773.10 | 0.39 | 253.43 | 13-JUN-17:10 | 1.00 |
| July | 80612040.18 | 0.46 | 255.07 | 22-JUL-18:00 | 1.00 |
| August | 56524436.46 | 0.41 | 202.31 | 14-AUG-17:10 | 1.02 |
| September | 27821568.92 | 0.38 | 155.45 | 13-SEP-16:30 | 1.03 |
| October | 57091846.91 | 0.73 | 59.52 | 23-OCT-06:40 | 0.93 |
| November | 0.102060E+09 | 0.91 | 95.77 | 29-NOV-04:00 | 0.93 |
| December | 0.152677E+09 | 0.93 | 105.83 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.945853E+09 | 0.66 | |||
| Minimum of Months | 27821568.92 | 0.38 | 59.52 | 0.93 | |
| Maximum of Months | 0.152677E+09 | 0.93 | 255.07 | 1.03 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 99943638.45 | 0.82 | 105.87 | 10-JAN-06:00 | 0.93 |
| February | 82988818.64 | 0.77 | 95.90 | 17-FEB-04:00 | 0.93 |
| March | 74611014.85 | 0.79 | 73.29 | 04-MAR-06:00 | 0.93 |
| April | 70072031.75 | 0.59 | 229.83 | 30-APR-14:10 | 1.00 |
| May | 60425068.71 | 0.56 | 195.51 | 22-MAY-14:20 | 1.01 |
| June | 79581712.99 | 0.48 | 231.28 | 13-JUN-14:10 | 0.99 |
| July | 0.114379E+09 | 0.55 | 265.15 | 22-JUL-13:30 | 0.98 |
| August | 0.122358E+09 | 0.53 | 226.82 | 14-AUG-13:10 | 1.00 |
| September | 92049893.15 | 0.54 | 212.89 | 12-SEP-14:10 | 1.00 |
| October | 57298982.51 | 0.68 | 130.32 | 07-OCT-15:10 | 1.04 |
| November | 80510718.16 | 0.80 | 89.41 | 29-NOV-04:00 | 0.93 |
| December | 0.130958E+09 | 0.89 | 101.88 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.106518E+10 | 0.67 | |||
| Minimum of Months | 57298982.51 | 0.48 | 73.29 | 0.93 | |
| Maximum of Months | 0.130958E+09 | 0.89 | 265.15 | 1.04 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.125026E+09 | 0.93 | 107.65 | 10-JAN-06:00 | 0.93 |
| February | 0.107108E+09 | 0.93 | 98.08 | 17-FEB-04:00 | 0.93 |
| March | 84787323.35 | 0.89 | 73.41 | 04-MAR-06:00 | 0.93 |
| April | 40228214.39 | 0.51 | 128.85 | 30-APR-16:20 | 1.03 |
| May | 37365419.23 | 0.49 | 130.07 | 22-MAY-15:10 | 1.03 |
| June | 51182344.87 | 0.44 | 180.20 | 13-JUN-16:12 | 1.00 |
| July | 72586444.22 | 0.52 | 193.25 | 22-JUL-16:20 | 1.00 |
| August | 57409612.07 | 0.46 | 144.41 | 14-AUG-16:12 | 1.02 |
| September | 23001089.37 | 0.37 | 104.66 | 13-SEP-16:05 | 1.04 |
| October | 54825033.47 | 0.71 | 58.87 | 23-OCT-06:35 | 0.93 |
| November | 99724512.00 | 0.93 | 93.41 | 29-NOV-04:00 | 0.93 |
| December | 0.147809E+09 | 0.93 | 104.38 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.901053E+09 | 0.67 | |||
| Minimum of Months | 23001089.37 | 0.37 | 58.87 | 0.93 | |
| Maximum of Months | 0.147809E+09 | 0.93 | 193.25 | 1.04 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 91379668.91 | 0.93 | 79.91 | 10-JAN-06:00 | 0.93 |
| February | 77757003.38 | 0.93 | 72.68 | 17-FEB-04:00 | 0.93 |
| March | 59796460.68 | 0.86 | 52.43 | 04-MAR-06:00 | 0.93 |
| April | 25698128.50 | 0.44 | 104.93 | 30-APR-16:30 | 1.04 |
| May | 20277474.52 | 0.38 | 101.05 | 22-MAY-15:20 | 1.04 |
| June | 34363753.40 | 0.36 | 154.44 | 13-JUN-17:00 | 1.01 |
| July | 51205756.42 | 0.45 | 164.82 | 22-JUL-18:00 | 1.01 |
| August | 35542913.86 | 0.41 | 121.98 | 14-AUG-17:20 | 1.03 |
| September | 10946542.23 | 0.24 | 87.68 | 13-SEP-16:30 | 1.04 |
| October | 35221059.97 | 0.68 | 41.51 | 23-OCT-05:00 | 0.93 |
| November | 68861512.03 | 0.91 | 68.71 | 29-NOV-04:00 | 0.93 |
| December | 0.106092E+09 | 0.93 | 76.36 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.617142E+09 | 0.62 | |||
| Minimum of Months | 10946542.23 | 0.24 | 41.51 | 0.93 | |
| Maximum of Months | 0.106092E+09 | 0.93 | 164.82 | 1.04 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 91300934.72 | 0.93 | 79.88 | 10-JAN-06:00 | 0.93 |
| February | 77808777.23 | 0.93 | 72.81 | 17-FEB-04:00 | 0.93 |
| March | 59745850.88 | 0.86 | 52.49 | 04-MAR-06:00 | 0.93 |
| April | 25730513.09 | 0.44 | 104.36 | 30-APR-16:30 | 1.04 |
| May | 20391905.90 | 0.38 | 101.43 | 22-MAY-15:10 | 1.04 |
| June | 34613883.02 | 0.36 | 152.77 | 13-JUN-17:00 | 1.01 |
| July | 51327062.78 | 0.45 | 163.11 | 22-JUL-18:00 | 1.01 |
| August | 36212734.32 | 0.41 | 120.60 | 14-AUG-17:20 | 1.03 |
| September | 11087187.16 | 0.24 | 87.04 | 13-SEP-16:12 | 1.04 |
| October | 35179247.81 | 0.68 | 41.48 | 23-OCT-05:00 | 0.93 |
| November | 68809322.09 | 0.91 | 68.59 | 29-NOV-04:00 | 0.93 |
| December | 0.105919E+09 | 0.93 | 76.40 | 30-DEC-02:00 | 0.93 |
| Annual Sum or Average | 0.618127E+09 | 0.63 | |||
| Minimum of Months | 11087187.16 | 0.24 | 41.48 | 0.93 | |
| Maximum of Months | 0.105919E+09 | 0.93 | 163.11 | 1.04 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 67153238.93 | 0.77 | 77.61 | 10-JAN-06:00 | 0.93 |
| February | 55348841.05 | 0.73 | 69.75 | 17-FEB-04:00 | 0.93 |
| March | 49851573.45 | 0.72 | 52.01 | 04-MAR-06:00 | 0.93 |
| April | 49854984.89 | 0.53 | 203.58 | 30-APR-15:10 | 1.01 |
| May | 40201286.11 | 0.45 | 167.27 | 22-MAY-15:10 | 1.02 |
| June | 62473567.37 | 0.46 | 198.38 | 13-JUN-14:20 | 1.01 |
| July | 92804218.50 | 0.53 | 226.51 | 22-JUL-13:50 | 1.00 |
| August | 0.101045E+09 | 0.54 | 199.71 | 14-AUG-14:30 | 1.01 |
| September | 76369141.80 | 0.48 | 191.65 | 12-SEP-14:30 | 1.01 |
| October | 37000719.44 | 0.57 | 123.40 | 07-OCT-15:10 | 1.04 |
| November | 50727367.80 | 0.76 | 63.92 | 29-NOV-04:00 | 0.93 |
| December | 89452204.37 | 0.87 | 74.22 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.772282E+09 | 0.62 | |||
| Minimum of Months | 37000719.44 | 0.45 | 52.01 | 0.93 | |
| Maximum of Months | 0.101045E+09 | 0.87 | 226.51 | 1.04 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 67132683.34 | 0.77 | 77.60 | 10-JAN-06:00 | 0.93 |
| February | 55450297.85 | 0.74 | 69.98 | 17-FEB-04:00 | 0.93 |
| March | 49837372.13 | 0.72 | 52.10 | 04-MAR-06:00 | 0.93 |
| April | 50392392.08 | 0.53 | 203.72 | 30-APR-14:20 | 1.01 |
| May | 40680481.98 | 0.46 | 167.66 | 22-MAY-14:40 | 1.02 |
| June | 62828684.04 | 0.46 | 198.71 | 13-JUN-14:10 | 1.00 |
| July | 93039976.86 | 0.53 | 227.10 | 22-JUL-13:40 | 0.99 |
| August | 0.101676E+09 | 0.54 | 200.08 | 14-AUG-14:30 | 1.00 |
| September | 77104155.93 | 0.48 | 192.13 | 12-SEP-14:20 | 1.01 |
| October | 37253018.80 | 0.57 | 123.37 | 07-OCT-15:10 | 1.04 |
| November | 50731670.99 | 0.76 | 63.78 | 29-NOV-04:00 | 0.93 |
| December | 89314121.70 | 0.87 | 74.23 | 30-DEC-04:00 | 0.93 |
| Annual Sum or Average | 0.775441E+09 | 0.62 | |||
| Minimum of Months | 37253018.80 | 0.46 | 52.10 | 0.93 | |
| Maximum of Months | 0.101676E+09 | 0.87 | 227.10 | 1.04 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.64 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.64 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.64 |
| September | 51857908.47 | 0.64 | 20.01 | 01-SEP-00:10 | 0.64 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.64 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 53586505.42 | 0.64 | 20.01 | 01-JAN-00:10 | 0.64 |
| February | 48400714.57 | 0.64 | 20.01 | 01-FEB-00:10 | 0.64 |
| March | 53586505.42 | 0.64 | 20.01 | 01-MAR-00:10 | 0.64 |
| April | 51857908.47 | 0.64 | 20.01 | 01-APR-00:10 | 0.64 |
| May | 53586505.42 | 0.64 | 20.01 | 01-MAY-00:10 | 0.64 |
| June | 51857908.47 | 0.63 | 20.01 | 01-JUN-00:10 | 0.63 |
| July | 53586505.42 | 0.63 | 20.01 | 01-JUL-00:10 | 0.63 |
| August | 53586505.42 | 0.63 | 20.01 | 01-AUG-00:10 | 0.63 |
| September | 51857908.47 | 0.63 | 20.01 | 01-SEP-00:10 | 0.63 |
| October | 53586505.42 | 0.64 | 20.01 | 01-OCT-00:10 | 0.64 |
| November | 51857908.47 | 0.64 | 20.01 | 01-NOV-00:10 | 0.64 |
| December | 53586505.42 | 0.64 | 20.01 | 01-DEC-00:10 | 0.64 |
| Annual Sum or Average | 0.630938E+09 | 0.64 | |||
| Minimum of Months | 48400714.57 | 0.63 | 20.01 | 0.63 | |
| Maximum of Months | 53586505.42 | 0.64 | 20.01 | 0.64 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 75702944.31 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 64933660.26 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 70379482.53 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 37844409.85 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 23698182.68 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 92638188.02 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.252614E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.282114E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.212045E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 36584849.15 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 47034773.20 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 93297081.82 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.128889E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 23698182.68 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.282114E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.101556E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 89552812.91 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 81267255.70 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 34772776.75 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 18191712.24 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 41302861.84 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.127678E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 73798796.16 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 13187482.35 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 28574056.98 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 66567714.14 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.108808E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.785257E+09 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 13187482.35 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.127678E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.110764E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.100044E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.110764E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.109621E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.115744E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.121923E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.134045E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.141354E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.130458E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.114804E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.107191E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.110764E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.140747E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.100044E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.141354E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 99530870.69 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 89392541.16 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 79719134.25 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 30536677.29 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 16199383.65 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 35753719.55 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.104633E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 75993726.81 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 12910571.78 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 27411064.94 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 65252060.72 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.105383E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.742716E+09 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 12910571.78 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.105383E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 67619800.68 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 60732045.61 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 51775432.99 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 20271640.89 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 8554686.92 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 23478693.59 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 84233853.87 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 53174272.84 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 6697209.29 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 13472670.93 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 40494261.96 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 70614761.07 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.501119E+09 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 6697209.29 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 84233853.87 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 67570348.89 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 60769672.95 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 51752259.54 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 20130966.90 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 8448143.10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 23436030.59 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 83598967.88 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 54352274.81 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 7367699.01 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 13427176.24 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 40468521.96 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 70503610.47 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.501826E+09 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 7367699.01 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 83598967.88 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 43753708.39 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 38167627.27 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 41828665.14 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 23813742.57 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 8738837.64 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 76493548.28 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.220271E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.294582E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.253779E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 38023079.30 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 22604563.80 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 56381760.54 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.111844E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 8738837.64 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.294582E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 49585992.25 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 42838106.88 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 46304245.13 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 26763258.88 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 9609232.81 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 86264719.15 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.245501E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.328208E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.278046E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 41088576.18 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 25020941.54 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 62845691.45 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.124208E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 9609232.81 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.328208E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 78499738.35 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 59698358.47 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 53392550.07 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.364985E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.347905E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.780117E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.110623E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.116475E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.915103E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.167691E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 52733347.46 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.134264E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.522537E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 52733347.46 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.116475E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.129277E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.107273E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 74522318.46 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 89881787.44 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.131325E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.540628E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.758601E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.602618E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.226056E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 22312936.46 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 93159716.02 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.167251E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.294291E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 22312936.46 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.758601E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 77099094.46 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 61069861.87 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 52593572.18 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.394089E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.345283E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.761094E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.108111E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.121173E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.979057E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.176279E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 51662002.98 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.129604E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.532067E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 51662002.98 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.121173E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.126723E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.108465E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 72587816.47 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 94570218.53 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.115166E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.522518E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.734514E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.651904E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.257838E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 20874315.37 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 91283998.47 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.161435E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.295788E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 20874315.37 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.734514E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 72738424.81 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 61844977.79 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 34355233.20 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 43978143.87 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 69904434.50 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.423395E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.578128E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.490249E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.193387E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 3951446.79 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 43098230.25 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 94465140.35 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.210949E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 3951446.79 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.578128E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 72678371.39 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 61988615.22 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 34378478.69 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 45990082.15 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 70303849.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.422762E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.578013E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.492702E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.199115E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 3920071.40 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 43071214.74 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 94269912.55 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.211919E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 3920071.40 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.578013E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 29852445.35 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 20387382.72 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 17126038.67 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.340083E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.299874E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.672311E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.936001E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.107505E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.948294E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.203776E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 13024174.27 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 63466207.84 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.461924E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 13024174.27 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.107505E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 29806443.93 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 20512563.36 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 17155969.86 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.345713E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.302905E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.671573E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.935760E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.107688E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.952260E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.204897E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 12998646.71 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 63266918.68 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.463373E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 12998646.71 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.107688E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.102463E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 89179023.58 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 76240011.45 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.234008E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.210305E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.350832E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.514431E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.511799E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.367469E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.111726E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 82735293.33 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.134788E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.278598E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 76240011.45 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.514431E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.127827E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.107665E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 86978438.72 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 94101949.27 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.107088E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.233043E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.342248E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.241492E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 90092876.83 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 57308698.45 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.102060E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.152677E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.174258E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 57308698.45 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.342248E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.100436E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 84273241.30 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 74904371.31 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.228930E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.194121E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.332795E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.487988E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.523409E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.380651E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.110549E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 80725403.15 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.130958E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.272974E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 74904371.31 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.523409E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.125026E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.107108E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 84787323.35 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 77633505.29 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 85179873.73 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.210626E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.308663E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.245244E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 74080299.14 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 54825033.47 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 99724512.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.147809E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.162071E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 54825033.47 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.308663E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 91379668.91 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 77757003.38 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 59796460.68 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 44520012.02 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 45253730.32 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.144840E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.220188E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.152381E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 37247762.19 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 35221059.97 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 68861512.03 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.106092E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.108354E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 35221059.97 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.220188E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 91300934.72 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 77808777.23 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 59745850.88 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 45047574.39 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 45807090.67 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.145835E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.220726E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.155247E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 38153832.87 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 35179247.81 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 68809322.09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.105919E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.108958E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 35179247.81 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.220726E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 68139262.36 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 58582253.79 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 49851573.45 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.172440E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.139815E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.265123E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.398457E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.432568E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.323927E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 84942400.91 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 51527487.23 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 89457638.88 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.213483E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 49851573.45 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.432568E+09 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 68145499.89 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 58674831.11 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 49837372.13 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.174929E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.141837E+09 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.266563E+09 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.399469E+09 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.435260E+09 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.327119E+09 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 86025334.42 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 51572587.77 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 89325510.38 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.214876E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 49837372.13 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.435260E+09 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 75702944.31 | 0.00 | 0.168483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64933660.26 | 0.00 | 0.144515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 70379482.53 | 0.00 | 0.156636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 21095350.18 | 65076793.14 | 0.354576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 12706716.26 | 42632282.06 | 0.208078E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 21648607.46 | 0.279356E+09 | 1964461.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 58713403.54 | 0.762467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 65866211.46 | 0.853427E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 49634037.96 | 0.639723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 19987339.26 | 63561559.57 | 0.330739E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 47034773.20 | 0.00 | 0.104680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 93297081.82 | 0.00 | 0.207641E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.601000E+09 | 0.270624E+10 | 0.871491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 12706716.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 93297081.82 | 0.853427E+09 | 0.207641E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.101556E+09 | 0.00 | 0.230587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 89552812.91 | 0.00 | 0.203333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 81267255.70 | 0.00 | 0.184521E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 32901695.62 | 7167460.98 | 0.733919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 17927340.39 | 1017409.88 | 0.405216E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 9964560.32 | 0.123480E+09 | 10912117.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 29604683.71 | 0.383914E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 17201133.91 | 0.221668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 3079069.06 | 39583713.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28574056.98 | 0.00 | 0.648786E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 66567714.14 | 0.00 | 0.151145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.108808E+09 | 0.00 | 0.247052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.587004E+09 | 0.776830E+09 | 0.119652E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3079069.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.108808E+09 | 0.383914E+09 | 0.247052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.110764E+10 | 0.00 | 0.479428E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100044E+10 | 0.00 | 0.308230E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.110764E+10 | 0.00 | 0.355792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107191E+10 | 93525698.73 | 5343180.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.110764E+10 | 0.194061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.107191E+10 | 0.585531E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.110764E+10 | 0.938942E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.110764E+10 | 0.123940E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.107191E+10 | 0.934986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.110764E+10 | 0.156332E+09 | 2144610.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107191E+10 | 0.00 | 0.124676E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.110764E+10 | 0.00 | 0.519060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.130415E+11 | 0.414278E+10 | 0.179467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.100044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.110764E+10 | 0.123940E+10 | 0.519060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 99530870.69 | 0.00 | 0.230028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 89392541.16 | 0.00 | 0.206597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 79719134.25 | 0.00 | 0.184241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 29341297.17 | 4554829.57 | 0.669579E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 16199383.65 | 0.00 | 0.374388E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 8881779.32 | 0.105752E+09 | 17181662.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 24241084.97 | 0.315189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 17718041.24 | 0.228362E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 3012384.96 | 38744785.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 27411064.94 | 0.00 | 0.633504E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 65252060.72 | 0.00 | 0.150806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105383E+09 | 0.00 | 0.243554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.566083E+09 | 0.692603E+09 | 0.118469E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3012384.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.105383E+09 | 0.315189E+09 | 0.243554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 67619800.68 | 0.00 | 0.157503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60732045.61 | 0.00 | 0.141460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51775432.99 | 0.00 | 0.120598E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 20071305.72 | 757326.33 | 0.466068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 8554686.92 | 0.00 | 0.199259E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 5478317.05 | 70535328.64 | 816638.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 19507096.95 | 0.252420E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 12389539.48 | 0.159482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1562937.37 | 20053896.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 13472670.93 | 0.00 | 0.313811E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 40494261.96 | 0.00 | 0.943210E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 70614761.07 | 0.00 | 0.164479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.372273E+09 | 0.503248E+09 | 0.776355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1562937.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70614761.07 | 0.252420E+09 | 0.164479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 67570348.89 | 0.00 | 0.157471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60769672.95 | 0.00 | 0.141622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51752259.54 | 0.00 | 0.120607E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 19908454.86 | 841369.19 | 0.462359E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 8448143.10 | 0.00 | 0.196882E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 5473525.88 | 70394015.40 | 965660.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 19359592.27 | 0.250522E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 12664759.14 | 0.163021E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1719230.05 | 22069411.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 13427176.24 | 0.00 | 0.312917E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 40468521.96 | 0.00 | 0.943108E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 70503610.47 | 0.00 | 0.164307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.372065E+09 | 0.506848E+09 | 0.775630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1719230.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70503610.47 | 0.250522E+09 | 0.164307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 43753708.39 | 0.00 | 0.989831E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 38167627.27 | 0.00 | 0.863459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 41828665.14 | 0.00 | 0.946282E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 10720466.63 | 50811677.74 | 0.151232E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4070737.54 | 18007421.32 | 59821165.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 17818314.22 | 0.230259E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 51192897.54 | 0.663741E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 68768230.12 | 0.890919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 59400911.91 | 0.765358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 12305257.14 | 98864379.80 | 98757718.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 22604563.80 | 0.00 | 0.511379E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 56381760.54 | 0.00 | 0.127551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.427013E+09 | 0.271796E+10 | 0.489627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 4070737.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68768230.12 | 0.890919E+09 | 0.127551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 49585992.25 | 0.00 | 0.112126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 42838106.88 | 0.00 | 0.968672E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 46304245.13 | 0.00 | 0.104705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 11777864.12 | 58207816.13 | 0.161885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4011695.97 | 21589932.33 | 52020384.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 20098829.67 | 0.259726E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 57073122.44 | 0.740773E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76623949.23 | 0.993323E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 65081630.91 | 0.839108E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 13043399.86 | 0.107889E+09 | 99156240.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 25020941.54 | 0.00 | 0.565784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 62845691.45 | 0.00 | 0.142109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.474305E+09 | 0.302062E+10 | 0.543692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 4011695.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 76623949.23 | 0.993323E+09 | 0.142109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 78499738.35 | 0.00 | 0.171437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 59698358.47 | 0.00 | 0.130376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 53392550.07 | 0.00 | 0.116605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87008661.95 | 0.108184E+10 | 24643556.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81830995.11 | 0.103663E+10 | 1693764.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.182295E+09 | 0.235628E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.257772E+09 | 0.334805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.272081E+09 | 0.353667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.214304E+09 | 0.277006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 45193425.44 | 0.473380E+09 | 0.161067E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52733347.46 | 0.00 | 0.115165E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.134264E+09 | 0.00 | 0.293220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.151907E+10 | 0.146029E+11 | 0.845543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45193425.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.272081E+09 | 0.353667E+10 | 0.293220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.129277E+09 | 0.00 | 0.285490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107273E+09 | 0.00 | 0.236896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 74522318.46 | 0.00 | 0.164572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 26661847.75 | 0.245342E+09 | 0.158099E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 31216289.93 | 0.391129E+09 | 12647313.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.126209E+09 | 0.163323E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.176615E+09 | 0.228995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.140641E+09 | 0.181715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 52831977.71 | 0.678816E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 22226827.95 | 326087.69 | 0.490261E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93159716.02 | 0.00 | 0.205730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.167251E+09 | 0.00 | 0.369349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.114788E+10 | 0.705595E+10 | 0.132814E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22226827.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.176615E+09 | 0.228995E+10 | 0.369349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 77099094.46 | 0.00 | 0.170445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61069861.87 | 0.00 | 0.135009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 52593572.18 | 0.00 | 0.116270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93862122.86 | 0.117011E+10 | 24367881.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81226583.23 | 0.102854E+10 | 2232537.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.177876E+09 | 0.230177E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.251989E+09 | 0.327787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.283085E+09 | 0.369419E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.229307E+09 | 0.297248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 46923232.16 | 0.500890E+09 | 0.154717E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 51662002.98 | 0.00 | 0.114211E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.129604E+09 | 0.00 | 0.286520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.153630E+10 | 0.149458E+11 | 0.840587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46923232.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.283085E+09 | 0.369419E+10 | 0.286520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.126723E+09 | 0.00 | 0.284320E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.108465E+09 | 0.00 | 0.243354E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 72587816.47 | 0.00 | 0.162860E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 26909910.26 | 0.261735E+09 | 0.135641E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 27407884.01 | 0.342366E+09 | 12759819.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.122001E+09 | 0.157816E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.171078E+09 | 0.221706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.152163E+09 | 0.196806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 60262523.95 | 0.772777E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 20874315.37 | 0.00 | 0.468341E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 91283998.47 | 0.00 | 0.204807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.161435E+09 | 0.00 | 0.362200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.114119E+10 | 0.714015E+10 | 0.131921E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20874315.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.171078E+09 | 0.221706E+10 | 0.362200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 72738424.81 | 0.00 | 0.164668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61844977.79 | 0.00 | 0.140007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 34355233.20 | 0.00 | 0.777747E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 11485931.93 | 0.125407E+09 | 33162629.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 16369632.03 | 0.207709E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 98793693.67 | 0.127353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.134576E+09 | 0.173753E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.114367E+09 | 0.147373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 45164907.28 | 0.578965E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 3951446.79 | 0.00 | 89454333.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 43098230.25 | 0.00 | 0.975674E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 94465140.35 | 0.00 | 0.213854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.731211E+09 | 0.539687E+10 | 0.706132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3951446.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134576E+09 | 0.173753E+10 | 0.213854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 72678371.39 | 0.00 | 0.164595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61988615.22 | 0.00 | 0.140386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 34378478.69 | 0.00 | 0.778572E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 11926527.60 | 0.131444E+09 | 32177077.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 16463341.54 | 0.208893E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 98647040.14 | 0.127162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.134553E+09 | 0.173706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.114941E+09 | 0.148120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 46504896.26 | 0.596065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 3920071.40 | 0.00 | 88778202.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 43071214.74 | 0.00 | 0.975438E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 94269912.55 | 0.00 | 0.213494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.733343E+09 | 0.542628E+10 | 0.705972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3920071.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134553E+09 | 0.173706E+10 | 0.213494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 29852445.35 | 0.00 | 0.663058E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20387382.72 | 0.00 | 0.452828E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 17126038.67 | 0.00 | 0.380390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 80447734.36 | 0.100721E+10 | 5012376.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 70482711.07 | 0.889398E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.157070E+09 | 0.202338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.218092E+09 | 0.282453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.251076E+09 | 0.326058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.222061E+09 | 0.286997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 48098328.85 | 0.603827E+09 | 1865436.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 13024174.27 | 0.00 | 0.289282E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 63466207.84 | 0.00 | 0.140966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119118E+10 | 0.134789E+11 | 0.320209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13024174.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.251076E+09 | 0.326058E+10 | 0.140966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 29806443.93 | 0.00 | 0.662233E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20512563.36 | 0.00 | 0.455744E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 17155969.86 | 0.00 | 0.381168E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81780805.97 | 0.102388E+10 | 5045229.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 71197250.65 | 0.898392E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.156899E+09 | 0.202131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.218040E+09 | 0.282396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.251506E+09 | 0.326665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.222991E+09 | 0.288238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 48364806.25 | 0.607242E+09 | 1939062.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 12998646.71 | 0.00 | 0.288801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 63266918.68 | 0.00 | 0.140565E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119452E+10 | 0.135238E+11 | 0.320058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 12998646.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.251506E+09 | 0.326665E+10 | 0.140565E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.101769E+09 | 2635833.07 | 0.220735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 84661748.07 | 17203967.62 | 0.180977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 76240011.45 | 0.00 | 0.165713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 72869424.96 | 0.631569E+09 | 0.500637E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 65334689.76 | 0.569624E+09 | 0.451318E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 83783294.78 | 0.106312E+10 | 50941655.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.120694E+09 | 0.156744E+10 | 24992081.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.119633E+09 | 0.156772E+10 | 1565277.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 89463762.47 | 0.110775E+10 | 96039739.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58553925.79 | 0.205954E+09 | 0.915647E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 82244617.51 | 1859155.39 | 0.178435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.134788E+09 | 0.00 | 0.292970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.109003E+10 | 0.673488E+10 | 0.124294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58553925.79 | 0.00 | 1565277.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134788E+09 | 0.156772E+10 | 0.292970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.127827E+09 | 0.00 | 0.279966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107665E+09 | 0.00 | 0.235807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 86978438.72 | 0.00 | 0.190500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 46528147.36 | 0.185146E+09 | 0.697288E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 43769127.97 | 0.248739E+09 | 0.533462E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 56298773.10 | 0.703084E+09 | 54416323.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 80612040.18 | 0.103537E+10 | 28545316.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 56524436.46 | 0.731085E+09 | 4649440.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 27821568.92 | 0.245300E+09 | 0.193243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 57091846.91 | 817147.60 | 0.124895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.102060E+09 | 0.00 | 0.223533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.152677E+09 | 0.00 | 0.334392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.945853E+09 | 0.314954E+10 | 0.154025E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27821568.92 | 0.00 | 4649440.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.152677E+09 | 0.103537E+10 | 0.334392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 99943638.45 | 1869198.16 | 0.220526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82988818.64 | 4890999.08 | 0.182515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 74611014.85 | 1112933.69 | 0.164680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 70072031.75 | 0.624582E+09 | 0.462832E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 60425068.71 | 0.526112E+09 | 0.427179E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 79581712.99 | 0.101119E+10 | 51851395.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.114379E+09 | 0.149398E+10 | 20330760.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.122358E+09 | 0.161424E+10 | 1670090.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 92049893.15 | 0.115454E+10 | 83067357.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 57298982.51 | 0.206579E+09 | 0.902781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 80510718.16 | 813964.05 | 0.177772E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.130958E+09 | 0.00 | 0.289401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106518E+10 | 0.663991E+10 | 0.122986E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 57298982.51 | 0.00 | 1670090.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.130958E+09 | 0.161424E+10 | 0.289401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.125026E+09 | 0.00 | 0.279511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107108E+09 | 0.00 | 0.239454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 84787323.35 | 0.00 | 0.189553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 40228214.39 | 0.145274E+09 | 0.641256E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 37365419.23 | 0.187702E+09 | 0.508164E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 51182344.87 | 0.634759E+09 | 58986442.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 72586444.22 | 0.935490E+09 | 23028938.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 57409612.07 | 0.742958E+09 | 4987280.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 23001089.37 | 0.201061E+09 | 0.166093E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 54825033.47 | 0.00 | 0.122568E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 99724512.00 | 0.00 | 0.222947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.147809E+09 | 0.00 | 0.330446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.901053E+09 | 0.284724E+10 | 0.152473E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23001089.37 | 0.00 | 4987280.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.147809E+09 | 0.935490E+09 | 0.330446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 91379668.91 | 0.00 | 0.204915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77757003.38 | 0.00 | 0.174366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59796460.68 | 0.00 | 0.134091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 25698128.50 | 72867359.43 | 0.446024E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20277474.52 | 97779366.42 | 0.283563E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 34363753.40 | 0.437300E+09 | 17401248.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 51205756.42 | 0.664905E+09 | 1415226.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 35542913.86 | 0.459338E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 10946542.23 | 0.103295E+09 | 65825785.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 35221059.97 | 0.00 | 0.789816E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 68861512.03 | 0.00 | 0.154419E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.106092E+09 | 0.00 | 0.237905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.617142E+09 | 0.183548E+10 | 0.106610E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 10946542.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.106092E+09 | 0.664905E+09 | 0.237905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 91300934.72 | 0.00 | 0.204917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77808777.23 | 0.00 | 0.174635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59745850.88 | 0.00 | 0.134094E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 25730513.09 | 74784678.07 | 0.443709E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20391905.90 | 99501676.40 | 0.283360E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 34613883.02 | 0.440265E+09 | 17910770.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 51327062.78 | 0.666604E+09 | 1240157.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 36212734.32 | 0.468061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 11087187.16 | 0.106311E+09 | 63803614.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 35179247.81 | 0.00 | 0.789566E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 68809322.09 | 0.00 | 0.154436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105919E+09 | 0.00 | 0.237726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.618127E+09 | 0.185553E+10 | 0.106577E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11087187.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.105919E+09 | 0.666604E+09 | 0.237726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 67153238.93 | 3758290.36 | 0.147955E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 55348841.05 | 12318837.35 | 0.120284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 49851573.45 | 0.00 | 0.110336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 49854984.89 | 0.479463E+09 | 0.264508E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 40201286.11 | 0.389649E+09 | 0.212265E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 62473567.37 | 0.803821E+09 | 15586952.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 92804218.50 | 0.121397E+10 | 1182927.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101045E+09 | 0.132583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 76369141.80 | 0.986470E+09 | 14473536.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 37000719.44 | 0.185706E+09 | 0.491220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50727367.80 | 3042810.39 | 0.111727E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 89452204.37 | 20417.49 | 0.197979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.772282E+09 | 0.540405E+10 | 0.788205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 37000719.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101045E+09 | 0.132583E+10 | 0.197979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 67132683.34 | 3861602.68 | 0.147990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 55450297.85 | 12287534.58 | 0.120595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 49837372.13 | 0.00 | 0.110378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 50392392.08 | 0.487218E+09 | 0.263191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 40680481.98 | 0.395800E+09 | 0.212486E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 62828684.04 | 0.808330E+09 | 16080069.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 93039976.86 | 0.121740E+10 | 1091512.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101676E+09 | 0.133468E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 77104155.93 | 0.996566E+09 | 14078905.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 37253018.80 | 0.188992E+09 | 0.491460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50731670.99 | 3198715.28 | 0.111783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 89314121.70 | 42809.93 | 0.197802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.775441E+09 | 0.544838E+10 | 0.788386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 37253018.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101676E+09 | 0.133468E+10 | 0.197802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 75702944.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64933660.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 70379482.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 21095350.18 | 0.00 | 0.00 | 0.00 | 16749059.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 12706716.26 | 0.00 | 0.00 | 0.00 | 10991466.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 21648607.46 | 0.00 | 0.00 | 0.00 | 70989580.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 58713403.54 | 0.00 | 0.00 | 0.00 | 0.193901E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 65866211.46 | 0.00 | 0.00 | 0.00 | 0.216247E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 49634037.96 | 0.00 | 0.00 | 0.00 | 0.162411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 19987339.26 | 0.00 | 0.00 | 0.00 | 16597509.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 47034773.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 93297081.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.601000E+09 | 0.00 | 0.00 | 0.00 | 0.687887E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 12706716.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 93297081.82 | 0.00 | 0.00 | 0.00 | 0.216247E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.101556E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 89552812.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 81267255.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 32901695.62 | 0.00 | 0.00 | 0.00 | 1871081.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 17927340.39 | 0.00 | 0.00 | 0.00 | 264371.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 9964560.32 | 0.00 | 0.00 | 0.00 | 31338301.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 29604683.71 | 0.00 | 0.00 | 0.00 | 98072971.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 17201133.91 | 0.00 | 0.00 | 0.00 | 56597662.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 3079069.06 | 0.00 | 0.00 | 0.00 | 10108413.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 28574056.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 66567714.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.108808E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.587004E+09 | 0.00 | 0.00 | 0.00 | 0.198253E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3079069.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.108808E+09 | 0.00 | 0.00 | 0.00 | 98072971.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.100044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107191E+10 | 0.00 | 0.00 | 0.00 | 24306206.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 49803757.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.107191E+10 | 0.00 | 0.00 | 0.00 | 0.147321E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 0.232812E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 0.305907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.107191E+10 | 0.00 | 0.00 | 0.00 | 0.232670E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 40400681.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.107191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.130415E+11 | 0.00 | 0.00 | 0.00 | 0.103322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.100044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.110764E+10 | 0.00 | 0.00 | 0.00 | 0.305907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 99530870.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 89392541.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 79719134.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 29341297.17 | 0.00 | 0.00 | 0.00 | 1195380.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 16199383.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 8881779.32 | 0.00 | 0.00 | 0.00 | 26871940.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 24241084.97 | 0.00 | 0.00 | 0.00 | 80392305.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 17718041.24 | 0.00 | 0.00 | 0.00 | 58275685.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 3012384.96 | 0.00 | 0.00 | 0.00 | 9898186.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 27411064.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 65252060.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105383E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.566083E+09 | 0.00 | 0.00 | 0.00 | 0.176633E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3012384.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.105383E+09 | 0.00 | 0.00 | 0.00 | 80392305.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 67619800.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60732045.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51775432.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 20071305.72 | 0.00 | 0.00 | 0.00 | 200335.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 8554686.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 5478317.05 | 0.00 | 0.00 | 0.00 | 18000376.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 19507096.95 | 0.00 | 0.00 | 0.00 | 64726756.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 12389539.48 | 0.00 | 0.00 | 0.00 | 40784733.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1562937.37 | 0.00 | 0.00 | 0.00 | 5134271.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 13472670.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 40494261.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 70614761.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.372273E+09 | 0.00 | 0.00 | 0.00 | 0.128846E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1562937.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70614761.07 | 0.00 | 0.00 | 0.00 | 64726756.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 67570348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60769672.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 51752259.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 19908454.86 | 0.00 | 0.00 | 0.00 | 222512.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 8448143.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 5473525.88 | 0.00 | 0.00 | 0.00 | 17962504.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 19359592.27 | 0.00 | 0.00 | 0.00 | 64239375.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 12664759.14 | 0.00 | 0.00 | 0.00 | 41687515.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 1719230.05 | 0.00 | 0.00 | 0.00 | 5648468.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 13427176.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 40468521.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 70503610.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.372065E+09 | 0.00 | 0.00 | 0.00 | 0.129760E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1719230.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 70503610.47 | 0.00 | 0.00 | 0.00 | 64239375.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 43753708.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 38167627.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 41828665.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 10720466.63 | 0.00 | 0.00 | 0.00 | 13093275.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4070737.54 | 0.00 | 0.00 | 0.00 | 4668100.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 17818314.22 | 0.00 | 0.00 | 0.00 | 58675234.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 51192897.54 | 0.00 | 0.00 | 0.00 | 0.169078E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 68768230.12 | 0.00 | 0.00 | 0.00 | 0.225814E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 59400911.91 | 0.00 | 0.00 | 0.00 | 0.194378E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 12305257.14 | 0.00 | 0.00 | 0.00 | 25717822.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 22604563.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 56381760.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.427013E+09 | 0.00 | 0.00 | 0.00 | 0.691424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 4070737.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68768230.12 | 0.00 | 0.00 | 0.00 | 0.225814E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 49585992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 42838106.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 46304245.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 11777864.12 | 0.00 | 0.00 | 0.00 | 14985394.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4011695.97 | 0.00 | 0.00 | 0.00 | 5597536.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 20098829.67 | 0.00 | 0.00 | 0.00 | 66165889.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 57073122.44 | 0.00 | 0.00 | 0.00 | 0.188428E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 76623949.23 | 0.00 | 0.00 | 0.00 | 0.251584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 65081630.91 | 0.00 | 0.00 | 0.00 | 0.212965E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 13043399.86 | 0.00 | 0.00 | 0.00 | 28045176.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 25020941.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 62845691.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.474305E+09 | 0.00 | 0.00 | 0.00 | 0.767770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 4011695.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 76623949.23 | 0.00 | 0.00 | 0.00 | 0.251584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 78499738.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 59698358.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 53392550.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 87008661.95 | 0.00 | 0.00 | 0.00 | 0.277976E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81830995.11 | 0.00 | 0.00 | 0.00 | 0.266074E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.182295E+09 | 0.00 | 0.00 | 0.00 | 0.597822E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.257772E+09 | 0.00 | 0.00 | 0.00 | 0.848460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.272081E+09 | 0.00 | 0.00 | 0.00 | 0.892665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.214304E+09 | 0.00 | 0.00 | 0.00 | 0.700800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 45193425.44 | 0.00 | 0.00 | 0.00 | 0.122498E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52733347.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.134264E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.151907E+10 | 0.00 | 0.00 | 0.00 | 0.370630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45193425.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.272081E+09 | 0.00 | 0.00 | 0.00 | 0.892665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.129277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 74522318.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 26661847.75 | 0.00 | 0.00 | 0.00 | 63219939.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 31216289.93 | 0.00 | 0.00 | 0.00 | 0.100109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.126209E+09 | 0.00 | 0.00 | 0.00 | 0.414419E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.176615E+09 | 0.00 | 0.00 | 0.00 | 0.581986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.140641E+09 | 0.00 | 0.00 | 0.00 | 0.461977E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 52831977.71 | 0.00 | 0.00 | 0.00 | 0.173224E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 22226827.95 | 0.00 | 0.00 | 0.00 | 86108.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93159716.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.167251E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.114788E+10 | 0.00 | 0.00 | 0.00 | 0.179502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22226827.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.176615E+09 | 0.00 | 0.00 | 0.00 | 0.581986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 77099094.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61069861.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 52593572.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 93862122.86 | 0.00 | 0.00 | 0.00 | 0.300227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 81226583.23 | 0.00 | 0.00 | 0.00 | 0.264056E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.177876E+09 | 0.00 | 0.00 | 0.00 | 0.583219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.251989E+09 | 0.00 | 0.00 | 0.00 | 0.829122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.283085E+09 | 0.00 | 0.00 | 0.00 | 0.928643E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.229307E+09 | 0.00 | 0.00 | 0.00 | 0.749750E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 46923232.16 | 0.00 | 0.00 | 0.00 | 0.129356E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 51662002.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.129604E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.153630E+10 | 0.00 | 0.00 | 0.00 | 0.378437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 46923232.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.283085E+09 | 0.00 | 0.00 | 0.00 | 0.928643E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.126723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.108465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 72587816.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 26909910.26 | 0.00 | 0.00 | 0.00 | 67660308.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 27407884.01 | 0.00 | 0.00 | 0.00 | 87757959.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.122001E+09 | 0.00 | 0.00 | 0.00 | 0.400517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.171078E+09 | 0.00 | 0.00 | 0.00 | 0.563436E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.152163E+09 | 0.00 | 0.00 | 0.00 | 0.499741E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 60262523.95 | 0.00 | 0.00 | 0.00 | 0.197576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 20874315.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 91283998.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.161435E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.114119E+10 | 0.00 | 0.00 | 0.00 | 0.181669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20874315.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.171078E+09 | 0.00 | 0.00 | 0.00 | 0.563436E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 72738424.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61844977.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 34355233.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 11485931.93 | 0.00 | 0.00 | 0.00 | 32492211.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 16369632.03 | 0.00 | 0.00 | 0.00 | 53534802.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 98793693.67 | 0.00 | 0.00 | 0.00 | 0.324601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.134576E+09 | 0.00 | 0.00 | 0.00 | 0.443553E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.114367E+09 | 0.00 | 0.00 | 0.00 | 0.375881E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 45164907.28 | 0.00 | 0.00 | 0.00 | 0.148222E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 3951446.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 43098230.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 94465140.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.731211E+09 | 0.00 | 0.00 | 0.00 | 0.137828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3951446.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134576E+09 | 0.00 | 0.00 | 0.00 | 0.443553E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 72678371.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61988615.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 34378478.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 11926527.60 | 0.00 | 0.00 | 0.00 | 34063554.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 16463341.54 | 0.00 | 0.00 | 0.00 | 53840507.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 98647040.14 | 0.00 | 0.00 | 0.00 | 0.324115E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.134553E+09 | 0.00 | 0.00 | 0.00 | 0.443460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.114941E+09 | 0.00 | 0.00 | 0.00 | 0.377761E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 46504896.26 | 0.00 | 0.00 | 0.00 | 0.152610E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 3920071.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 43071214.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 94269912.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.733343E+09 | 0.00 | 0.00 | 0.00 | 0.138585E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 3920071.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134553E+09 | 0.00 | 0.00 | 0.00 | 0.443460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 29852445.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20387382.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 17126038.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 80447734.36 | 0.00 | 0.00 | 0.00 | 0.259635E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 70482711.07 | 0.00 | 0.00 | 0.00 | 0.229392E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.157070E+09 | 0.00 | 0.00 | 0.00 | 0.515240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.218092E+09 | 0.00 | 0.00 | 0.00 | 0.717909E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.251076E+09 | 0.00 | 0.00 | 0.00 | 0.823972E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.222061E+09 | 0.00 | 0.00 | 0.00 | 0.726234E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 48098328.85 | 0.00 | 0.00 | 0.00 | 0.155678E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 13024174.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 63466207.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119118E+10 | 0.00 | 0.00 | 0.00 | 0.342806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13024174.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.251076E+09 | 0.00 | 0.00 | 0.00 | 0.823972E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 29806443.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20512563.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 17155969.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 81780805.97 | 0.00 | 0.00 | 0.00 | 0.263932E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 71197250.65 | 0.00 | 0.00 | 0.00 | 0.231708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.156899E+09 | 0.00 | 0.00 | 0.00 | 0.514674E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.218040E+09 | 0.00 | 0.00 | 0.00 | 0.717721E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.251506E+09 | 0.00 | 0.00 | 0.00 | 0.825374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.222991E+09 | 0.00 | 0.00 | 0.00 | 0.729269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 48364806.25 | 0.00 | 0.00 | 0.00 | 0.156532E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 12998646.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 63266918.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.119452E+10 | 0.00 | 0.00 | 0.00 | 0.343921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 12998646.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.251506E+09 | 0.00 | 0.00 | 0.00 | 0.825374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.101769E+09 | 0.00 | 0.00 | 0.00 | 694266.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 84661748.07 | 0.00 | 0.00 | 0.00 | 4517275.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 76240011.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 72869424.96 | 0.00 | 0.00 | 0.00 | 0.161139E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 65334689.76 | 0.00 | 0.00 | 0.00 | 0.144970E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 83783294.78 | 0.00 | 0.00 | 0.00 | 0.267048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.120694E+09 | 0.00 | 0.00 | 0.00 | 0.393738E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.119633E+09 | 0.00 | 0.00 | 0.00 | 0.392166E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 89463762.47 | 0.00 | 0.00 | 0.00 | 0.278005E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 58553925.79 | 0.00 | 0.00 | 0.00 | 53172092.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 82244617.51 | 0.00 | 0.00 | 0.00 | 490675.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.134788E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.109003E+10 | 0.00 | 0.00 | 0.00 | 0.169594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 58553925.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.134788E+09 | 0.00 | 0.00 | 0.00 | 0.393738E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.127827E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 86978438.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 46528147.36 | 0.00 | 0.00 | 0.00 | 47573801.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 43769127.97 | 0.00 | 0.00 | 0.00 | 63318410.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 56298773.10 | 0.00 | 0.00 | 0.00 | 0.176745E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 80612040.18 | 0.00 | 0.00 | 0.00 | 0.261636E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 56524436.46 | 0.00 | 0.00 | 0.00 | 0.184968E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 27821568.92 | 0.00 | 0.00 | 0.00 | 62271307.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 57091846.91 | 0.00 | 0.00 | 0.00 | 216851.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.102060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.152677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.945853E+09 | 0.00 | 0.00 | 0.00 | 0.796728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 27821568.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.152677E+09 | 0.00 | 0.00 | 0.00 | 0.261636E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 99943638.45 | 0.00 | 0.00 | 0.00 | 492119.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 82988818.64 | 0.00 | 0.00 | 0.00 | 1284422.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 74611014.85 | 0.00 | 0.00 | 0.00 | 293356.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 70072031.75 | 0.00 | 0.00 | 0.00 | 0.158858E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 60425068.71 | 0.00 | 0.00 | 0.00 | 0.133696E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 79581712.99 | 0.00 | 0.00 | 0.00 | 0.253213E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.114379E+09 | 0.00 | 0.00 | 0.00 | 0.373609E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.122358E+09 | 0.00 | 0.00 | 0.00 | 0.401051E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 92049893.15 | 0.00 | 0.00 | 0.00 | 0.288601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 57298982.51 | 0.00 | 0.00 | 0.00 | 53250066.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 80510718.16 | 0.00 | 0.00 | 0.00 | 214684.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.130958E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106518E+10 | 0.00 | 0.00 | 0.00 | 0.166456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 57298982.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.130958E+09 | 0.00 | 0.00 | 0.00 | 0.401051E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.125026E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.107108E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 84787323.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 40228214.39 | 0.00 | 0.00 | 0.00 | 37405290.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 37365419.23 | 0.00 | 0.00 | 0.00 | 47814454.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 51182344.87 | 0.00 | 0.00 | 0.00 | 0.159443E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 72586444.22 | 0.00 | 0.00 | 0.00 | 0.236076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 57409612.07 | 0.00 | 0.00 | 0.00 | 0.187835E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 23001089.37 | 0.00 | 0.00 | 0.00 | 51079209.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 54825033.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 99724512.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.147809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.901053E+09 | 0.00 | 0.00 | 0.00 | 0.719653E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23001089.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.147809E+09 | 0.00 | 0.00 | 0.00 | 0.236076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 91379668.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77757003.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59796460.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 25698128.50 | 0.00 | 0.00 | 0.00 | 18821883.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20277474.52 | 0.00 | 0.00 | 0.00 | 24976255.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 34363753.40 | 0.00 | 0.00 | 0.00 | 0.110477E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 51205756.42 | 0.00 | 0.00 | 0.00 | 0.168982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 35542913.86 | 0.00 | 0.00 | 0.00 | 0.116839E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 10946542.23 | 0.00 | 0.00 | 0.00 | 26301219.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 35221059.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 68861512.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.106092E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.617142E+09 | 0.00 | 0.00 | 0.00 | 0.466396E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 10946542.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.106092E+09 | 0.00 | 0.00 | 0.00 | 0.168982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 91300934.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 77808777.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 59745850.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 25730513.09 | 0.00 | 0.00 | 0.00 | 19317061.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 20391905.90 | 0.00 | 0.00 | 0.00 | 25415184.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 34613883.02 | 0.00 | 0.00 | 0.00 | 0.111221E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 51327062.78 | 0.00 | 0.00 | 0.00 | 0.169399E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 36212734.32 | 0.00 | 0.00 | 0.00 | 0.119034E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 11087187.16 | 0.00 | 0.00 | 0.00 | 27066645.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 35179247.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 68809322.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.105919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.618127E+09 | 0.00 | 0.00 | 0.00 | 0.471453E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 11087187.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.105919E+09 | 0.00 | 0.00 | 0.00 | 0.169399E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 67153238.93 | 0.00 | 0.00 | 0.00 | 986023.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 55348841.05 | 0.00 | 0.00 | 0.00 | 3233412.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 49851573.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 49854984.89 | 0.00 | 0.00 | 0.00 | 0.122585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 40201286.11 | 0.00 | 0.00 | 0.00 | 99613410.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 62473567.37 | 0.00 | 0.00 | 0.00 | 0.202649E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 92804218.50 | 0.00 | 0.00 | 0.00 | 0.305653E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101045E+09 | 0.00 | 0.00 | 0.00 | 0.331523E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 76369141.80 | 0.00 | 0.00 | 0.00 | 0.247558E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 37000719.44 | 0.00 | 0.00 | 0.00 | 47941681.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50727367.80 | 0.00 | 0.00 | 0.00 | 800119.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 89452204.37 | 0.00 | 0.00 | 0.00 | 5434.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.772282E+09 | 0.00 | 0.00 | 0.00 | 0.136255E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 37000719.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101045E+09 | 0.00 | 0.00 | 0.00 | 0.331523E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 67132683.34 | 0.00 | 0.00 | 0.00 | 1012816.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 55450297.85 | 0.00 | 0.00 | 0.00 | 3224533.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 49837372.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 50392392.08 | 0.00 | 0.00 | 0.00 | 0.124537E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 40680481.98 | 0.00 | 0.00 | 0.00 | 0.101157E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 62828684.04 | 0.00 | 0.00 | 0.00 | 0.203734E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 93039976.86 | 0.00 | 0.00 | 0.00 | 0.306429E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.101676E+09 | 0.00 | 0.00 | 0.00 | 0.333585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 77104155.93 | 0.00 | 0.00 | 0.00 | 0.250015E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 37253018.80 | 0.00 | 0.00 | 0.00 | 48772315.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 50731670.99 | 0.00 | 0.00 | 0.00 | 840916.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 89314121.70 | 0.00 | 0.00 | 0.00 | 11388.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.775441E+09 | 0.00 | 0.00 | 0.00 | 0.137332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 37253018.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.101676E+09 | 0.00 | 0.00 | 0.00 | 0.333585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.334763E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110590E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.357221E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.935766E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.264232E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103052E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.868622E+09 | 577.46 | 0.00 | 162751.26 | 276262.27 | 0.165989E+09 | 29937594.50 | 0.00 | 0.35 |
| May | 0.880451E+09 | 248314.27 | 0.00 | 168756.29 | 0.00 | 0.104433E+09 | 44337416.24 | 0.00 | 0.35 |
| June | 0.637083E+09 | 6805942.70 | 0.00 | 656056.26 | 0.00 | 0.00 | 0.192302E+09 | 0.00 | 0.35 |
| July | 0.402112E+09 | 8666243.70 | 0.00 | 1672817.10 | 0.00 | 0.00 | 0.335115E+09 | 0.00 | 0.35 |
| August | 0.275578E+09 | 1149760.01 | 0.00 | 2121080.10 | 0.00 | 0.00 | 0.420238E+09 | 0.00 | 0.35 |
| September | 0.446259E+09 | 717528.14 | 0.00 | 1802105.21 | 0.00 | 0.00 | 0.412723E+09 | 0.00 | 0.35 |
| October | 0.873637E+09 | 0.00 | 0.00 | 313088.71 | 0.00 | 0.124609E+09 | 84662352.10 | 0.00 | 0.35 |
| November | 0.563809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.624268E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.125588E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131473E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.602935E+10 | 17588366.28 | 0.00 | 6896654.93 | 276262.27 | 0.540621E+10 | 0.151932E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.125588E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.880451E+09 | 8666243.70 | 0.00 | 2121080.10 | 276262.27 | 0.131473E+10 | 0.420238E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 19129183.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142026E+10 | 0.00 | 0.00 | 0.35 |
| February | 20869773.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127122E+10 | 0.00 | 0.00 | 0.35 |
| March | 78916087.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121770E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.555080E+09 | 0.00 | 0.00 | 10834.83 | 428971.54 | 0.464702E+09 | 542811.63 | 0.00 | 0.35 |
| May | 0.767116E+09 | 4677.24 | 0.00 | 18287.57 | 245478.84 | 0.207672E+09 | 9350155.80 | 0.00 | 0.35 |
| June | 0.718718E+09 | 4884780.71 | 0.00 | 225828.72 | 0.00 | 0.00 | 80671851.48 | 0.00 | 0.35 |
| July | 0.499945E+09 | 8060028.18 | 0.00 | 883681.24 | 0.00 | 0.00 | 0.232162E+09 | 0.00 | 0.35 |
| August | 0.513802E+09 | 157373.72 | 0.00 | 707270.74 | 0.00 | 0.00 | 0.178321E+09 | 0.00 | 0.35 |
| September | 0.756412E+09 | 13486.44 | 0.00 | 128168.81 | 0.00 | 0.00 | 37205095.65 | 0.00 | 0.35 |
| October | 0.655401E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362613E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.166171E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101950E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144000E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.475156E+10 | 13120346.29 | 0.00 | 1974071.91 | 674450.38 | 0.740367E+10 | 0.538253E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.767116E+09 | 8060028.18 | 0.00 | 883681.24 | 428971.54 | 0.144000E+10 | 0.232162E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.149250E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373487E+09 | 0.00 | 0.00 | 0.51 |
| February | 0.140502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279797E+09 | 0.00 | 0.00 | 0.51 |
| March | 0.134183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.364196E+09 | 0.00 | 0.00 | 0.51 |
| April | 0.149099E+10 | 22549.65 | 0.00 | 169071.99 | 143265.73 | 1071088.84 | 0.104163E+09 | 0.00 | 0.52 |
| May | 0.143392E+10 | 89929.64 | 0.00 | 323301.41 | 0.00 | 0.00 | 0.151857E+09 | 0.00 | 0.52 |
| June | 0.106195E+10 | 4490238.62 | 0.00 | 792505.56 | 1740614.34 | 0.00 | 0.224563E+09 | 0.00 | 0.52 |
| July | 0.101537E+10 | 1750893.04 | 0.00 | 1349778.12 | 156403.16 | 0.00 | 0.163482E+09 | 0.00 | 0.52 |
| August | 0.980323E+09 | 2062273.92 | 0.00 | 1755474.90 | 0.00 | 0.00 | 0.155000E+09 | 0.00 | 0.52 |
| September | 0.116017E+10 | 695686.99 | 0.00 | 1433292.59 | 3115.03 | 0.00 | 0.185082E+09 | 0.00 | 0.52 |
| October | 0.151756E+10 | 0.00 | 0.00 | 284578.72 | 0.00 | 612080.15 | 0.105573E+09 | 0.00 | 0.52 |
| November | 0.150416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123921E+09 | 0.00 | 0.00 | 0.51 |
| December | 0.140781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.425560E+09 | 0.00 | 0.00 | 0.51 |
| Annual Sum or Average | 0.158116E+11 | 9111571.85 | 0.00 | 6108003.29 | 2043398.26 | 0.156864E+10 | 0.108972E+10 | 0.00 | 0.52 |
| Minimum of Months | 0.980323E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 |
| Maximum of Months | 0.151756E+10 | 4490238.62 | 0.00 | 1755474.90 | 1740614.34 | 0.425560E+09 | 0.224563E+09 | 0.00 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 4106594.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143532E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129214E+10 | 0.00 | 0.00 | 0.35 |
| March | 53499324.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124312E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.624637E+09 | 0.00 | 0.00 | 6696.49 | 337769.72 | 0.397435E+09 | 710491.32 | 0.00 | 0.35 |
| May | 0.805117E+09 | 0.00 | 0.00 | 0.00 | 262911.48 | 0.178496E+09 | 0.00 | 0.00 | 0.35 |
| June | 0.733162E+09 | 4683665.88 | 0.00 | 184681.68 | 0.00 | 301061.68 | 63639198.49 | 0.00 | 0.35 |
| July | 0.530466E+09 | 8558799.19 | 0.00 | 683434.12 | 0.00 | 0.00 | 0.211647E+09 | 0.00 | 0.35 |
| August | 0.478379E+09 | 293792.40 | 0.00 | 720927.55 | 0.00 | 0.00 | 0.220357E+09 | 0.00 | 0.35 |
| September | 0.773483E+09 | 24328.38 | 0.00 | 108500.94 | 0.00 | 0.00 | 35390551.53 | 0.00 | 0.35 |
| October | 0.673791E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.345334E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.162335E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102334E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144001E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.483897E+10 | 13560585.84 | 0.00 | 1704240.77 | 600681.20 | 0.735549E+10 | 0.531745E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.805117E+09 | 8558799.19 | 0.00 | 720927.55 | 337769.72 | 0.144001E+10 | 0.220357E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.313991E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112715E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.242729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105196E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.506766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.791884E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.917732E+09 | 0.00 | 0.00 | 869.40 | 412489.65 | 0.102512E+09 | 269494.58 | 0.00 | 0.35 |
| May | 0.978454E+09 | 0.00 | 0.00 | 0.00 | 441271.07 | 11550101.30 | 0.00 | 0.00 | 0.35 |
| June | 0.721882E+09 | 4013413.78 | 0.00 | 215215.09 | 0.00 | 0.00 | 99454833.24 | 0.00 | 0.35 |
| July | 0.483175E+09 | 7863347.52 | 0.00 | 740216.48 | 0.00 | 0.00 | 0.277536E+09 | 0.00 | 0.35 |
| August | 0.463062E+09 | 135880.97 | 0.00 | 633318.98 | 0.00 | 0.00 | 0.252139E+09 | 0.00 | 0.35 |
| September | 0.784036E+09 | 0.00 | 0.00 | 91032.61 | 0.00 | 0.00 | 44218741.38 | 0.00 | 0.35 |
| October | 0.102486E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6796528.04 | 0.00 | 0.00 | 0.35 |
| November | 0.756437E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.433280E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.144919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129958E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.733804E+10 | 12012642.27 | 0.00 | 1680652.56 | 853760.73 | 0.482471E+10 | 0.673619E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.144919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.102486E+10 | 7863347.52 | 0.00 | 740216.48 | 441271.07 | 0.129958E+10 | 0.277536E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.314051E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112709E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.237748E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105695E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.508428E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.790222E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.918149E+09 | 0.00 | 0.00 | 995.27 | 407045.21 | 0.102494E+09 | 293796.77 | 0.00 | 0.35 |
| May | 0.978234E+09 | 0.00 | 0.00 | 0.00 | 437237.68 | 11864099.32 | 0.00 | 0.00 | 0.35 |
| June | 0.722334E+09 | 4013387.33 | 0.00 | 210446.74 | 0.00 | 0.00 | 98361383.83 | 0.00 | 0.35 |
| July | 0.485104E+09 | 7878935.06 | 0.00 | 729214.43 | 0.00 | 0.00 | 0.276731E+09 | 0.00 | 0.35 |
| August | 0.457822E+09 | 141356.21 | 0.00 | 647357.71 | 0.00 | 0.00 | 0.257906E+09 | 0.00 | 0.35 |
| September | 0.782886E+09 | 0.00 | 0.00 | 97079.19 | 0.00 | 0.00 | 47666038.79 | 0.00 | 0.35 |
| October | 0.102416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7681248.40 | 0.00 | 0.00 | 0.35 |
| November | 0.755714E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.434003E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.148846E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129566E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.733348E+10 | 12033678.61 | 0.00 | 1685093.34 | 844282.89 | 0.482595E+10 | 0.680959E+09 | 0.00 | 0.35 |
| Minimum of Months | 0.148846E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.102416E+10 | 7878935.06 | 0.00 | 729214.43 | 437237.68 | 0.129566E+10 | 0.276731E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.102741E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.417370E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.940238E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356993E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.839168E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.457978E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.104592E+10 | 0.00 | 0.00 | 128169.80 | 224591.07 | 8598989.32 | 30157238.52 | 0.00 | 0.35 |
| May | 0.100936E+10 | 238229.03 | 0.00 | 109536.72 | 0.00 | 0.00 | 48874228.56 | 0.00 | 0.35 |
| June | 0.591762E+09 | 6328662.81 | 0.00 | 710307.61 | 0.00 | 0.00 | 0.266003E+09 | 0.00 | 0.35 |
| July | 0.285311E+09 | 8504711.41 | 0.00 | 1726038.12 | 0.00 | 0.00 | 0.475810E+09 | 0.00 | 0.35 |
| August | 86397712.38 | 1216658.13 | 0.00 | 2552566.61 | 0.00 | 0.00 | 0.617590E+09 | 0.00 | 0.35 |
| September | 0.261654E+09 | 691878.56 | 0.00 | 2453209.87 | 0.00 | 0.00 | 0.616033E+09 | 0.00 | 0.35 |
| October | 0.975267E+09 | 0.00 | 0.00 | 468869.32 | 0.00 | 0.00 | 0.145528E+09 | 0.00 | 0.35 |
| November | 0.110264E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 94251585.00 | 0.00 | 0.00 | 0.35 |
| December | 0.639580E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.805700E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.880472E+10 | 16980139.95 | 0.00 | 8148698.04 | 224591.07 | 0.214089E+10 | 0.220000E+10 | 0.00 | 0.35 |
| Minimum of Months | 86397712.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.110264E+10 | 8504711.41 | 0.00 | 2552566.61 | 224591.07 | 0.805700E+09 | 0.617590E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.859228E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.584783E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.763836E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.532499E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.665598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.631353E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.103845E+10 | 0.00 | 0.00 | 152858.69 | 210850.44 | 12117283.85 | 36944002.75 | 0.00 | 0.35 |
| May | 0.100364E+10 | 239606.69 | 0.00 | 129937.66 | 0.00 | 0.00 | 59329255.73 | 0.00 | 0.35 |
| June | 0.568035E+09 | 6458211.14 | 0.00 | 800481.26 | 0.00 | 0.00 | 0.292179E+09 | 0.00 | 0.35 |
| July | 0.249582E+09 | 8649106.29 | 0.00 | 1924067.88 | 0.00 | 0.00 | 0.510336E+09 | 0.00 | 0.35 |
| August | 57093140.07 | 1296619.55 | 0.00 | 2831260.30 | 0.00 | 0.00 | 0.643502E+09 | 0.00 | 0.35 |
| September | 0.240711E+09 | 741067.67 | 0.00 | 2628743.46 | 0.00 | 0.00 | 0.635924E+09 | 0.00 | 0.35 |
| October | 0.969756E+09 | 0.00 | 0.00 | 497783.15 | 0.00 | 0.00 | 0.153071E+09 | 0.00 | 0.35 |
| November | 0.102618E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169990E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.458025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.987078E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.790014E+10 | 17384611.34 | 0.00 | 8965132.41 | 210850.44 | 0.291782E+10 | 0.233129E+10 | 0.00 | 0.35 |
| Minimum of Months | 57093140.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.103845E+10 | 8649106.29 | 0.00 | 2831260.30 | 210850.44 | 0.987078E+09 | 0.643502E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.200992E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.898209E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.200259E+10 | 0.00 | 0.00 | 948.61 | 0.00 | 0.614324E+09 | 3293033.36 | 0.00 | 0.35 |
| March | 0.220964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404950E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.169606E+10 | 168097.01 | 0.00 | 3428900.66 | 28002.34 | 0.00 | 0.670700E+09 | 0.00 | 0.35 |
| May | 0.151153E+10 | 653682.48 | 0.00 | 3492268.99 | 0.00 | 0.00 | 0.763957E+09 | 0.00 | 0.35 |
| June | 0.501478E+09 | 17024338.47 | 0.00 | 5965929.35 | 0.00 | 0.00 | 0.122213E+10 | 0.00 | 0.35 |
| July | 0.292430E+09 | 19106159.45 | 0.00 | 7543402.60 | 0.00 | 0.00 | 0.117466E+10 | 0.00 | 0.35 |
| August | 99645128.88 | 3515234.83 | 0.00 | 8395812.79 | 0.00 | 0.00 | 0.124999E+10 | 0.00 | 0.35 |
| September | 0.531740E+09 | 2513673.93 | 0.00 | 6974183.92 | 0.00 | 0.00 | 0.117903E+10 | 0.00 | 0.35 |
| October | 0.187158E+10 | 0.00 | 0.00 | 1694149.47 | 0.00 | 34517566.80 | 0.347132E+09 | 0.00 | 0.35 |
| November | 0.182654E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.572323E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.946684E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193033E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.154998E+11 | 42981186.17 | 0.00 | 37495596.39 | 28002.34 | 0.445465E+10 | 0.661090E+10 | 0.00 | 0.35 |
| Minimum of Months | 99645128.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.220964E+10 | 19106159.45 | 0.00 | 8395812.79 | 28002.34 | 0.193033E+10 | 0.124999E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.108863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178712E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.109710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148243E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.182171E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.775395E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.207299E+10 | 20317.93 | 0.00 | 717457.15 | 279050.11 | 1330957.72 | 0.146547E+09 | 0.00 | 0.35 |
| May | 0.185576E+10 | 427879.46 | 0.00 | 1426598.80 | 0.00 | 0.00 | 0.351610E+09 | 0.00 | 0.35 |
| June | 0.644292E+09 | 14429940.80 | 0.00 | 4585834.85 | 0.00 | 0.00 | 0.108700E+10 | 0.00 | 0.35 |
| July | 0.364348E+09 | 18017077.53 | 0.00 | 5737114.83 | 0.00 | 0.00 | 0.112268E+10 | 0.00 | 0.35 |
| August | 0.313248E+09 | 1158911.99 | 0.00 | 5118377.60 | 0.00 | 0.00 | 0.107678E+10 | 0.00 | 0.35 |
| September | 0.105978E+10 | 500255.53 | 0.00 | 2377569.64 | 0.00 | 0.00 | 0.646050E+09 | 0.00 | 0.35 |
| October | 0.195554E+10 | 0.00 | 0.00 | 30490.15 | 0.00 | 0.144115E+09 | 14873709.55 | 0.00 | 0.35 |
| November | 0.120718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115899E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.301462E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.257018E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.137820E+11 | 34554383.24 | 0.00 | 19993443.02 | 279050.11 | 0.791956E+10 | 0.444553E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.301462E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.207299E+10 | 18017077.53 | 0.00 | 5737114.83 | 279050.11 | 0.257018E+10 | 0.112268E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.205198E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.857002E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.196633E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.649806E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.223023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.385110E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.160629E+10 | 196514.36 | 0.00 | 3639573.98 | 0.00 | 0.00 | 0.781458E+09 | 0.00 | 0.35 |
| May | 0.146072E+10 | 652450.74 | 0.00 | 3450397.03 | 0.00 | 0.00 | 0.827909E+09 | 0.00 | 0.35 |
| June | 0.544651E+09 | 16828671.95 | 0.00 | 5817922.75 | 0.00 | 0.00 | 0.117993E+10 | 0.00 | 0.35 |
| July | 0.292023E+09 | 20110532.44 | 0.00 | 7355996.13 | 0.00 | 0.00 | 0.118423E+10 | 0.00 | 0.35 |
| August | 0.116676E+09 | 4216952.74 | 0.00 | 8688799.92 | 0.00 | 0.00 | 0.123031E+10 | 0.00 | 0.35 |
| September | 0.511469E+09 | 2521700.95 | 0.00 | 7366928.96 | 0.00 | 0.00 | 0.120061E+10 | 0.00 | 0.35 |
| October | 0.185742E+10 | 0.00 | 0.00 | 1694225.09 | 0.00 | 40017142.94 | 0.360694E+09 | 0.00 | 0.35 |
| November | 0.183853E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560049E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.991241E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188678E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.154676E+11 | 44526823.19 | 0.00 | 38013843.86 | 0.00 | 0.437876E+10 | 0.676514E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.116676E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.223023E+10 | 20110532.44 | 0.00 | 8688799.92 | 0.00 | 0.188678E+10 | 0.123031E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.112536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175026E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.110451E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147461E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.181847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.777177E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.198650E+10 | 212393.46 | 0.00 | 853514.18 | 0.00 | 24860089.46 | 0.236805E+09 | 0.00 | 0.35 |
| May | 0.186945E+10 | 437480.95 | 0.00 | 1230338.79 | 0.00 | 0.00 | 0.357211E+09 | 0.00 | 0.35 |
| June | 0.649598E+09 | 14129765.13 | 0.00 | 4498430.60 | 0.00 | 0.00 | 0.108250E+10 | 0.00 | 0.35 |
| July | 0.389030E+09 | 19153480.98 | 0.00 | 5624291.59 | 0.00 | 0.00 | 0.110787E+10 | 0.00 | 0.35 |
| August | 0.309656E+09 | 1787986.33 | 0.00 | 5404155.68 | 0.00 | 0.00 | 0.107693E+10 | 0.00 | 0.35 |
| September | 0.943111E+09 | 434029.31 | 0.00 | 2720892.46 | 0.00 | 0.00 | 0.778252E+09 | 0.00 | 0.35 |
| October | 0.198408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136767E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.123450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113107E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.381538E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249012E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.137958E+11 | 36155136.16 | 0.00 | 20331623.31 | 0.00 | 0.778486E+10 | 0.463956E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.309656E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.198650E+10 | 19153480.98 | 0.00 | 5624291.59 | 0.00 | 0.249012E+10 | 0.110787E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.247501E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.408035E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.238241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204246E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.261147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2102997.96 | 0.00 | 0.00 | 0.35 |
| April | 0.210323E+10 | 18117.51 | 0.00 | 465155.78 | 236349.60 | 0.00 | 0.158469E+09 | 0.00 | 0.35 |
| May | 0.188261E+10 | 376839.23 | 0.00 | 1047295.99 | 0.00 | 0.00 | 0.399842E+09 | 0.00 | 0.35 |
| June | 0.335868E+09 | 12560548.25 | 0.00 | 4721024.99 | 0.00 | 0.00 | 0.142864E+10 | 0.00 | 0.35 |
| July | 0.164022E+09 | 17266486.27 | 0.00 | 5416883.14 | 0.00 | 0.00 | 0.135748E+10 | 0.00 | 0.35 |
| August | 74344911.30 | 845791.19 | 0.00 | 5084361.19 | 0.00 | 0.00 | 0.133666E+10 | 0.00 | 0.35 |
| September | 0.793593E+09 | 224163.19 | 0.00 | 2670978.89 | 0.00 | 0.00 | 0.962542E+09 | 0.00 | 0.35 |
| October | 0.218425E+10 | 0.00 | 0.00 | 2984.38 | 0.00 | 0.00 | 9635537.40 | 0.00 | 0.35 |
| November | 0.221359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170200E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.221029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.672660E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.194307E+11 | 31291945.64 | 0.00 | 19408684.37 | 236349.60 | 0.145724E+10 | 0.565326E+10 | 0.00 | 0.35 |
| Minimum of Months | 74344911.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.261147E+10 | 17266486.27 | 0.00 | 5416883.14 | 236349.60 | 0.672660E+09 | 0.142864E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.247510E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407928E+09 | 0.00 | 0.00 | 0.35 |
| February | 0.237881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207841E+09 | 0.00 | 0.00 | 0.35 |
| March | 0.261143E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2103001.66 | 0.00 | 0.00 | 0.35 |
| April | 0.209055E+10 | 18003.16 | 0.00 | 500245.00 | 229086.79 | 0.00 | 0.175300E+09 | 0.00 | 0.35 |
| May | 0.188254E+10 | 379411.51 | 0.00 | 1057809.22 | 0.00 | 0.00 | 0.402881E+09 | 0.00 | 0.35 |
| June | 0.345923E+09 | 12570236.87 | 0.00 | 4705134.81 | 0.00 | 0.00 | 0.141858E+10 | 0.00 | 0.35 |
| July | 0.162973E+09 | 17299752.94 | 0.00 | 5408732.74 | 0.00 | 0.00 | 0.135916E+10 | 0.00 | 0.35 |
| August | 74452948.58 | 864724.98 | 0.00 | 5093646.75 | 0.00 | 0.00 | 0.133643E+10 | 0.00 | 0.35 |
| September | 0.778931E+09 | 229072.50 | 0.00 | 2731810.19 | 0.00 | 0.00 | 0.978179E+09 | 0.00 | 0.35 |
| October | 0.218498E+10 | 0.00 | 0.00 | 3455.59 | 0.00 | 0.00 | 10119320.36 | 0.00 | 0.35 |
| November | 0.221421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169511E+09 | 0.00 | 0.00 | 0.35 |
| December | 0.221700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665954E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.194169E+11 | 31361201.97 | 0.00 | 19500834.32 | 229086.79 | 0.145334E+10 | 0.568065E+10 | 0.00 | 0.35 |
| Minimum of Months | 74452948.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.261143E+10 | 17299752.94 | 0.00 | 5408732.74 | 229086.79 | 0.665954E+09 | 0.141858E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.291580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43985220.06 | 0.00 | 0.00 | 0.35 |
| February | 0.263996E+10 | 0.00 | 0.00 | 8105.86 | 0.00 | 14220343.91 | 8905323.41 | 0.00 | 0.35 |
| March | 0.265322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| April | 0.144559E+10 | 185915.06 | 0.00 | 3674942.16 | 0.00 | 0.00 | 0.990929E+09 | 0.00 | 0.35 |
| May | 0.128630E+10 | 626629.44 | 0.00 | 3556353.59 | 0.00 | 0.00 | 0.106810E+10 | 0.00 | 0.35 |
| June | 0.215460E+09 | 15727926.34 | 0.00 | 6169883.46 | 0.00 | 0.00 | 0.153524E+10 | 0.00 | 0.35 |
| July | 0.121013E+09 | 18439724.59 | 0.00 | 7127253.67 | 0.00 | 0.00 | 0.137234E+10 | 0.00 | 0.35 |
| August | 8945063.39 | 3398790.86 | 0.00 | 8332894.72 | 0.00 | 0.00 | 0.134619E+10 | 0.00 | 0.35 |
| September | 0.231001E+09 | 2206224.25 | 0.00 | 7922525.05 | 0.00 | 0.00 | 0.150123E+10 | 0.00 | 0.35 |
| October | 0.177552E+10 | 0.00 | 0.00 | 2211053.28 | 0.00 | 0.00 | 0.592715E+09 | 0.00 | 0.35 |
| November | 0.246735E+10 | 0.00 | 0.00 | 3059.79 | 0.00 | 0.00 | 6583111.06 | 0.00 | 0.35 |
| December | 0.261764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281795E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.183778E+11 | 40585210.53 | 0.00 | 39006071.58 | 0.00 | 0.340000E+09 | 0.842223E+10 | 0.00 | 0.35 |
| Minimum of Months | 8945063.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.291580E+10 | 18439724.59 | 0.00 | 8332894.72 | 0.00 | 0.281795E+09 | 0.153524E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.291597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43985242.83 | 0.00 | 0.00 | 0.35 |
| February | 0.263855E+10 | 0.00 | 0.00 | 8331.70 | 0.00 | 15139027.01 | 8909116.97 | 0.00 | 0.35 |
| March | 0.265329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| April | 0.143528E+10 | 186008.68 | 0.00 | 3725181.35 | 0.00 | 0.00 | 0.100333E+10 | 0.00 | 0.35 |
| May | 0.128005E+10 | 627509.95 | 0.00 | 3584734.61 | 0.00 | 0.00 | 0.107543E+10 | 0.00 | 0.35 |
| June | 0.218806E+09 | 15737838.46 | 0.00 | 6153787.33 | 0.00 | 0.00 | 0.153192E+10 | 0.00 | 0.35 |
| July | 0.118959E+09 | 18469536.61 | 0.00 | 7125559.85 | 0.00 | 0.00 | 0.137500E+10 | 0.00 | 0.35 |
| August | 9227564.70 | 3425060.02 | 0.00 | 8338273.30 | 0.00 | 0.00 | 0.134589E+10 | 0.00 | 0.35 |
| September | 0.227272E+09 | 2216475.53 | 0.00 | 7944279.02 | 0.00 | 0.00 | 0.150497E+10 | 0.00 | 0.35 |
| October | 0.177406E+10 | 0.00 | 0.00 | 2217394.27 | 0.00 | 0.00 | 0.594743E+09 | 0.00 | 0.35 |
| November | 0.246731E+10 | 0.00 | 0.00 | 3255.55 | 0.00 | 0.00 | 6586144.24 | 0.00 | 0.35 |
| December | 0.261854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281061E+09 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.183573E+11 | 40662429.26 | 0.00 | 39100796.98 | 0.00 | 0.340185E+09 | 0.844679E+10 | 0.00 | 0.35 |
| Minimum of Months | 9227564.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.291597E+10 | 18469536.61 | 0.00 | 8338273.30 | 0.00 | 0.281061E+09 | 0.153192E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.310400E+09 | 0.00 | 0.00 | 16441.99 | 0.00 | 0.112633E+10 | 11471431.92 | 0.00 | 0.35 |
| February | 0.335131E+09 | 0.00 | 0.00 | 102862.81 | 0.00 | 0.932292E+09 | 38218389.66 | 0.00 | 0.35 |
| March | 0.423810E+09 | 0.00 | 0.00 | 1176.71 | 0.00 | 0.876621E+09 | 1093712.61 | 0.00 | 0.35 |
| April | 0.555432E+09 | 3644.14 | 0.00 | 1824253.51 | 338904.43 | 0.318188E+09 | 0.234091E+09 | 0.00 | 0.35 |
| May | 0.578675E+09 | 346006.57 | 0.00 | 1614698.35 | 0.00 | 0.246028E+09 | 0.210671E+09 | 0.00 | 0.35 |
| June | 0.495637E+09 | 9021988.07 | 0.00 | 2095177.07 | 0.00 | 25466585.40 | 0.266260E+09 | 0.00 | 0.35 |
| July | 0.418914E+09 | 9786992.99 | 0.00 | 2796619.83 | 0.00 | 11058066.59 | 0.255113E+09 | 0.00 | 0.35 |
| August | 0.388682E+09 | 1885437.19 | 0.00 | 3056439.77 | 0.00 | 0.00 | 0.238546E+09 | 0.00 | 0.35 |
| September | 0.483109E+09 | 1408518.44 | 0.00 | 2339911.36 | 0.00 | 50027032.29 | 0.241613E+09 | 0.00 | 0.35 |
| October | 0.416714E+09 | 0.00 | 0.00 | 701090.05 | 0.00 | 0.532522E+09 | 0.103687E+09 | 0.00 | 0.35 |
| November | 0.252315E+09 | 0.00 | 0.00 | 29682.11 | 0.00 | 0.921561E+09 | 17321074.15 | 0.00 | 0.35 |
| December | 0.130001E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130494E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.478882E+10 | 22452587.39 | 0.00 | 14578353.56 | 338904.43 | 0.634503E+10 | 0.161809E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.130001E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.578675E+09 | 9786992.99 | 0.00 | 3056439.77 | 338904.43 | 0.130494E+10 | 0.266260E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 83627748.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135253E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.141779E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114562E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.287918E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100686E+10 | 0.00 | 0.00 | 0.35 |
| April | 0.566502E+09 | 13332.63 | 0.00 | 581867.84 | 363149.53 | 0.416270E+09 | 85721368.43 | 0.00 | 0.35 |
| May | 0.605396E+09 | 243189.39 | 0.00 | 740558.40 | 0.00 | 0.299653E+09 | 0.108960E+09 | 0.00 | 0.35 |
| June | 0.536686E+09 | 7740903.26 | 0.00 | 1445982.48 | 0.00 | 26664650.86 | 0.222109E+09 | 0.00 | 0.35 |
| July | 0.452234E+09 | 9212384.92 | 0.00 | 1961683.64 | 0.00 | 12367214.78 | 0.221249E+09 | 0.00 | 0.35 |
| August | 0.435721E+09 | 655896.90 | 0.00 | 1703185.46 | 0.00 | 65871.89 | 0.193911E+09 | 0.00 | 0.35 |
| September | 0.529565E+09 | 291985.91 | 0.00 | 634375.32 | 0.00 | 0.118460E+09 | 96379754.30 | 0.00 | 0.35 |
| October | 0.314568E+09 | 0.00 | 0.00 | 15654.96 | 0.00 | 0.695997E+09 | 5492569.74 | 0.00 | 0.35 |
| November | 82752010.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109622E+10 | 0.00 | 0.00 | 0.35 |
| December | 210829.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143179E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.403696E+10 | 18157693.01 | 0.00 | 7083308.10 | 363149.53 | 0.760250E+10 | 0.933823E+09 | 0.00 | 0.35 |
| Minimum of Months | 210829.32 | 0.00 | 0.00 | 0.00 | 0.00 | 65871.89 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.605396E+09 | 9212384.92 | 0.00 | 1961683.64 | 363149.53 | 0.143179E+10 | 0.222109E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.302385E+09 | 0.00 | 0.00 | 13796.60 | 0.00 | 0.113437E+10 | 12047492.43 | 0.00 | 0.35 |
| February | 0.353308E+09 | 0.00 | 0.00 | 33791.03 | 0.00 | 0.926490E+09 | 23386919.51 | 0.00 | 0.35 |
| March | 0.424526E+09 | 0.00 | 0.00 | 7635.91 | 0.00 | 0.872750E+09 | 3719400.54 | 0.00 | 0.35 |
| April | 0.552344E+09 | 1150.22 | 0.00 | 1707559.53 | 210109.67 | 0.291731E+09 | 0.274023E+09 | 0.00 | 0.35 |
| May | 0.588449E+09 | 346010.77 | 0.00 | 1379068.34 | 0.00 | 0.233870E+09 | 0.220812E+09 | 0.00 | 0.35 |
| June | 0.488404E+09 | 8915824.50 | 0.00 | 1928316.52 | 0.00 | 26494280.19 | 0.276786E+09 | 0.00 | 0.35 |
| July | 0.406810E+09 | 10418342.55 | 0.00 | 2561128.33 | 0.00 | 5979269.11 | 0.280261E+09 | 0.00 | 0.35 |
| August | 0.381722E+09 | 2320414.22 | 0.00 | 3021714.99 | 0.00 | 0.00 | 0.249147E+09 | 0.00 | 0.35 |
| September | 0.487476E+09 | 1416808.16 | 0.00 | 2319494.47 | 0.00 | 39579561.75 | 0.254045E+09 | 0.00 | 0.35 |
| October | 0.420132E+09 | 0.00 | 0.00 | 642720.27 | 0.00 | 0.525075E+09 | 0.110364E+09 | 0.00 | 0.35 |
| November | 0.267299E+09 | 0.00 | 0.00 | 9186.86 | 0.00 | 0.916043E+09 | 7501067.97 | 0.00 | 0.35 |
| December | 0.139873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129557E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.481273E+10 | 23418550.43 | 0.00 | 13624412.87 | 210109.67 | 0.626795E+10 | 0.171209E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.139873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.588449E+09 | 10418342.55 | 0.00 | 3021714.99 | 210109.67 | 0.129557E+10 | 0.280261E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 69409852.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136681E+10 | 0.00 | 0.00 | 0.35 |
| February | 84271856.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120292E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.294543E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.999992E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.604789E+09 | 11008.05 | 0.00 | 442592.31 | 229110.79 | 0.382345E+09 | 92810301.94 | 0.00 | 0.35 |
| May | 0.624267E+09 | 245982.08 | 0.00 | 518079.31 | 0.00 | 0.288952E+09 | 0.110890E+09 | 0.00 | 0.35 |
| June | 0.509209E+09 | 7583420.52 | 0.00 | 1297932.32 | 0.00 | 31395878.71 | 0.252013E+09 | 0.00 | 0.35 |
| July | 0.419523E+09 | 9899518.51 | 0.00 | 1732976.96 | 0.00 | 8764826.39 | 0.268842E+09 | 0.00 | 0.35 |
| August | 0.419909E+09 | 1000647.42 | 0.00 | 1590766.05 | 0.00 | 972048.67 | 0.216235E+09 | 0.00 | 0.35 |
| September | 0.559773E+09 | 230628.57 | 0.00 | 500654.31 | 0.00 | 97790299.75 | 0.102916E+09 | 0.00 | 0.35 |
| October | 0.331285E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.685157E+09 | 0.00 | 0.00 | 0.35 |
| November | 58114532.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112074E+10 | 0.00 | 0.00 | 0.35 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143202E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.397509E+10 | 18971205.16 | 0.00 | 6083001.27 | 229110.79 | 0.761785E+10 | 0.104371E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 972048.67 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.624267E+09 | 9899518.51 | 0.00 | 1732976.96 | 229110.79 | 0.143202E+10 | 0.268842E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.200244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123867E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.245491E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104578E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.490816E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.807215E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.744469E+09 | 11657.58 | 0.00 | 226229.90 | 332097.52 | 0.278192E+09 | 49309341.63 | 0.00 | 0.35 |
| May | 0.800196E+09 | 217776.90 | 0.00 | 298479.22 | 0.00 | 0.154858E+09 | 73956050.31 | 0.00 | 0.35 |
| June | 0.556559E+09 | 6888292.22 | 0.00 | 1038400.77 | 0.00 | 7055555.30 | 0.254428E+09 | 0.00 | 0.35 |
| July | 0.452214E+09 | 8869069.81 | 0.00 | 1376185.79 | 0.00 | 0.00 | 0.267572E+09 | 0.00 | 0.35 |
| August | 0.442560E+09 | 497560.81 | 0.00 | 1180841.01 | 0.00 | 0.00 | 0.220323E+09 | 0.00 | 0.35 |
| September | 0.670219E+09 | 109241.94 | 0.00 | 296961.37 | 0.00 | 18362642.78 | 80052428.34 | 0.00 | 0.35 |
| October | 0.538292E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.482268E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.243551E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.941016E+09 | 0.00 | 0.00 | 0.35 |
| December | 12541577.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142605E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.539715E+10 | 16593599.26 | 0.00 | 4417098.07 | 332097.52 | 0.639946E+10 | 0.945641E+09 | 0.00 | 0.35 |
| Minimum of Months | 12541577.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.800196E+09 | 8869069.81 | 0.00 | 1376185.79 | 332097.52 | 0.142605E+10 | 0.267572E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.201537E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123738E+10 | 0.00 | 0.00 | 0.35 |
| February | 0.239502E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105177E+10 | 0.00 | 0.00 | 0.35 |
| March | 0.491204E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.806864E+09 | 0.00 | 0.00 | 0.35 |
| April | 0.745799E+09 | 11564.96 | 0.00 | 232583.91 | 327992.14 | 0.276271E+09 | 51463874.92 | 0.00 | 0.35 |
| May | 0.798844E+09 | 219716.28 | 0.00 | 303055.14 | 0.00 | 0.155954E+09 | 75379715.11 | 0.00 | 0.35 |
| June | 0.551441E+09 | 6904442.30 | 0.00 | 1043701.37 | 0.00 | 7055194.26 | 0.259861E+09 | 0.00 | 0.35 |
| July | 0.448583E+09 | 8905055.06 | 0.00 | 1381968.78 | 0.00 | 0.00 | 0.272000E+09 | 0.00 | 0.35 |
| August | 0.441038E+09 | 520452.00 | 0.00 | 1194414.27 | 0.00 | 0.00 | 0.222047E+09 | 0.00 | 0.35 |
| September | 0.671026E+09 | 115478.47 | 0.00 | 299466.76 | 0.00 | 17223383.59 | 82003598.29 | 0.00 | 0.35 |
| October | 0.539613E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.481204E+09 | 0.00 | 0.00 | 0.35 |
| November | 0.244277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.940288E+09 | 0.00 | 0.00 | 0.35 |
| December | 12733313.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142585E+10 | 0.00 | 0.00 | 0.35 |
| Annual Sum or Average | 0.538560E+10 | 16676709.08 | 0.00 | 4455190.23 | 327992.14 | 0.639986E+10 | 0.962755E+09 | 0.00 | 0.35 |
| Minimum of Months | 12733313.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.798844E+09 | 8905055.06 | 0.00 | 1381968.78 | 327992.14 | 0.142585E+10 | 0.272000E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.541957E+09 | 0.00 | 0.00 | 29534.63 | 0.00 | 0.895259E+09 | 19352573.21 | 0.00 | 0.35 |
| February | 0.525905E+09 | 0.00 | 0.00 | 89459.10 | 0.00 | 0.745401E+09 | 42383638.87 | 0.00 | 0.35 |
| March | 0.618898E+09 | 0.00 | 0.00 | 1953.66 | 0.00 | 0.686713E+09 | 2198998.48 | 0.00 | 0.35 |
| April | 0.759793E+09 | 1447.88 | 0.00 | 1458559.19 | 288486.41 | 0.109957E+09 | 0.255670E+09 | 0.00 | 0.35 |
| May | 0.748416E+09 | 334193.88 | 0.00 | 1163844.40 | 0.00 | 96388680.46 | 0.213956E+09 | 0.00 | 0.35 |
| June | 0.504432E+09 | 8469721.72 | 0.00 | 1725809.66 | 0.00 | 7892744.25 | 0.306653E+09 | 0.00 | 0.35 |
| July | 0.400975E+09 | 9523450.03 | 0.00 | 2285005.64 | 0.00 | 0.00 | 0.315518E+09 | 0.00 | 0.35 |
| August | 0.374972E+09 | 1880195.23 | 0.00 | 2665332.85 | 0.00 | 0.00 | 0.281028E+09 | 0.00 | 0.35 |
| September | 0.521097E+09 | 1267672.58 | 0.00 | 2156280.72 | 0.00 | 0.00 | 0.285088E+09 | 0.00 | 0.35 |
| October | 0.672581E+09 | 0.00 | 0.00 | 640926.17 | 0.00 | 0.279268E+09 | 0.120342E+09 | 0.00 | 0.35 |
| November | 0.531009E+09 | 0.00 | 0.00 | 37845.71 | 0.00 | 0.649599E+09 | 21923110.07 | 0.00 | 0.35 |
| December | 0.269592E+09 | 0.00 | 0.00 | 4395.95 | 0.00 | 0.117064E+10 | 3661019.20 | 0.00 | 0.35 |
| Annual Sum or Average | 0.646963E+10 | 21476681.31 | 0.00 | 12258947.67 | 288486.41 | 0.464111E+10 | 0.186777E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.269592E+09 | 0.00 | 0.00 | 1953.66 | 0.00 | 0.00 | 2198998.48 | 0.00 | 0.35 |
| Maximum of Months | 0.759793E+09 | 9523450.03 | 0.00 | 2665332.85 | 288486.41 | 0.117064E+10 | 0.315518E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.541015E+09 | 0.00 | 0.00 | 31385.83 | 0.00 | 0.895720E+09 | 19960318.32 | 0.00 | 0.35 |
| February | 0.524280E+09 | 0.00 | 0.00 | 86088.60 | 0.00 | 0.746919E+09 | 42361883.01 | 0.00 | 0.35 |
| March | 0.618134E+09 | 0.00 | 0.00 | 3091.92 | 0.00 | 0.687122E+09 | 2627811.70 | 0.00 | 0.35 |
| April | 0.757122E+09 | 1322.39 | 0.00 | 1476586.13 | 285807.75 | 0.109410E+09 | 0.259740E+09 | 0.00 | 0.35 |
| May | 0.748236E+09 | 335086.61 | 0.00 | 1173435.33 | 0.00 | 95795760.57 | 0.215200E+09 | 0.00 | 0.35 |
| June | 0.504332E+09 | 8482484.02 | 0.00 | 1729336.52 | 0.00 | 8185365.84 | 0.306325E+09 | 0.00 | 0.35 |
| July | 0.398172E+09 | 9553636.78 | 0.00 | 2294003.84 | 0.00 | 0.00 | 0.318624E+09 | 0.00 | 0.35 |
| August | 0.374158E+09 | 1909181.97 | 0.00 | 2673599.03 | 0.00 | 0.00 | 0.281723E+09 | 0.00 | 0.35 |
| September | 0.519722E+09 | 1278993.40 | 0.00 | 2171792.41 | 0.00 | 0.00 | 0.286585E+09 | 0.00 | 0.35 |
| October | 0.672276E+09 | 0.00 | 0.00 | 644784.88 | 0.00 | 0.279317E+09 | 0.120745E+09 | 0.00 | 0.35 |
| November | 0.530375E+09 | 0.00 | 0.00 | 37971.89 | 0.00 | 0.649739E+09 | 22436479.66 | 0.00 | 0.35 |
| December | 0.269668E+09 | 0.00 | 0.00 | 4701.02 | 0.00 | 0.117064E+10 | 3664868.77 | 0.00 | 0.35 |
| Annual Sum or Average | 0.645749E+10 | 21560705.17 | 0.00 | 12326777.41 | 285807.75 | 0.464284E+10 | 0.187999E+10 | 0.00 | 0.35 |
| Minimum of Months | 0.269668E+09 | 0.00 | 0.00 | 3091.92 | 0.00 | 0.00 | 2627811.70 | 0.00 | 0.35 |
| Maximum of Months | 0.757122E+09 | 9553636.78 | 0.00 | 2673599.03 | 285807.75 | 0.117064E+10 | 0.318624E+09 | 0.00 | 0.35 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:15:07
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.528741E+11 | 0.677507E+10 | 0.00 | 0.186558E+10 | 0.107199E+11 |
| February | 0.761539E+11 | 0.757180E+10 | 0.00 | 0.168482E+10 | 0.905167E+10 |
| March | 0.835889E+11 | 0.624734E+10 | 0.00 | 0.170603E+10 | 0.748379E+10 |
| April | 0.207116E+12 | 0.685682E+10 | 0.00 | 0.159623E+10 | 0.118765E+11 |
| May | 0.243653E+12 | 0.116229E+11 | 0.00 | 0.158601E+10 | 0.109032E+11 |
| June | 0.242737E+12 | 0.105577E+11 | 0.00 | 0.128107E+10 | 0.277614E+11 |
| July | 0.246259E+12 | 0.119697E+11 | 0.00 | 0.117829E+10 | 0.418374E+11 |
| August | 0.206297E+12 | 0.123812E+11 | 0.00 | 0.113502E+10 | 0.419449E+11 |
| September | 0.161029E+12 | 0.100618E+11 | 0.00 | 0.134599E+10 | 0.281384E+11 |
| October | 0.812354E+11 | 0.769388E+10 | 0.00 | 0.162403E+10 | 0.696646E+10 |
| November | 0.385666E+11 | 0.857481E+10 | 0.00 | 0.162808E+10 | 0.736958E+10 |
| December | 0.222668E+11 | 0.109815E+11 | 0.00 | 0.183337E+10 | 0.137186E+11 |
| Annual Sum or Average | 0.166178E+13 | 0.111295E+12 | 0.00 | 0.184645E+11 | 0.217772E+12 |
| Minimum of Months | 0.222668E+11 | 0.624734E+10 | 0.00 | 0.113502E+10 | 0.696646E+10 |
| Maximum of Months | 0.246259E+12 | 0.123812E+11 | 0.00 | 0.186558E+10 | 0.419449E+11 |